Mixed Signal Oscilloscopes
HMO Mixed Signal Oscilloscopes
HMO3000 Series
Key facts
❙ 300 MHz to 500 MHz bandwidth
❙ 4 GSa /s real time, low noise flash A /D converter
❙ 8 MPts memory, Zoom up to 200,000:1
❙ MSO functionality included as standard
(HO3508/HO3516 logic probe with 8/16
channels required)
❙ Automatically or manually adjustable memory depth
*1)
All HMO oscilloscopes, *1) HMO300x, HMO202x, HMO152x only
HMO300x only
HMO3000 bandwidth upgrade options
Bandwidth upgrade to 500 MHz
Option
For 300 MHz 2-Channel HMO3032
HOO352
For 300 MHz 4-Channel HMO3034
HOO354
For 400 MHz 2-Channel HMO3042
HOO452
For 400 MHz 4-Channel HMO3044
HOO454
The bandwidth can easily be upgraded at any later point in time with option upgrade vouchers available at your dealer. The voucher enables you to generate the respective licence key directly on a dedicated web page.
HMO compact series only
Options for all HMO series oscilloscopes
Serial bus analysis HOO10 | HOO11 | HOO12
Designation
Type
Analysis of I2C, SPI and UART/RS-232 signals on HOO10
analog and logic channels. Two buses can be analyzed at the same time
Analysis of I2C, SPI and UART/RS-232 signals on all HOO11
analog channels.
Only one bus available for analysis
Analysis of CAN and LIN signals on analog and logic HOO12
channels for two buses
❙
❙
❙
❙
Hardware accelerated triggering and decoding in real-time
Display data in ASCII, binary, decimal or hexadecimal format
Powerful trigger to isolate specific data packages Detailed Zoom also available for serial bus analysis
2 HAMEG INSTRUMENTS | Product Overview
HEX decoded CAN bus signal
Trigger to START condition of I2C data package
❙ Color-coded display of decoded bus signals
❙ Directly export analyzed data to USB flash drive
❙ Add serial bus options to all HMO oscilloscopes with software licence keys at any time Mixed Signal Oscilloscopes
HMO Compact Series
Key facts
❙
❙
❙
❙
70 MHz to 200 MHz bandwidth
2 GSa/s real time, low noise flash A/D converter
2 MPts memory, Zoom up to 50,000:1
MSO functionality included as standard
(HO3508 logic probe with 8 channels required)
All HMO oscilloscopes features
❙ Vertical sensitivity up to 1 mV/div.
❙ Trigger modes: slope (A/B), pulse width, video, logic, serial buses (optional), hold-off*
❙ Serial bus trigger and hardware accelerated decode incl. list
view. Options: I2C + SPI + UART/RS-232 (HOO10/HOO11), CAN + LIN (HOO12)
❙ 28 auto-measurement parameters plus statistics,
formula editor, ratio cursor
❙
❙
❙
❙
❙
6-digit hardware counter
FFT up to 64kPts (dBm, dBV, Vrms)
Pass/fail test based on masks
Automatic search for user-defined events
Display: 12 div. x-Axis, 20 div. y-Axis (Virtual Screen)
*HMO3000 models only
HMO series at a glance
HMO3000 series
Bandwidth
500 MHz
400 MHz
300 MHz
200 MHz
150 MHz
100 MHz
70 MHz
Model: 4 channel
2 channel
Sampling rate (per analog channel)
HMO3054
HMO3052
2 GSa/s
HMO3044
HMO3042
HMO3034
HMO3032
HMO2024
HMO2022
1 GSa/s
HMO1524
HMO1522
HMO1024
HMO1022
HMO724
HMO722
Maximum sampling rate
4 GSa/s
2 GSa/s
Memory depth per channel
4 MPts.
1 MPts.
Maximum memory
8 MPts.
2 MPts.
Max number of logic channels
16
8
Input impedance
1 MΩ / 50 Ω
1 MΩ / 50 Ω
V/div. @ 1 MΩ
1 mV/div. to 5 V/div.
1 mV/div. to 10 V/div.
V/div. @ 50 Ω
1 mV/div. to 1 V/div.
1 mV/div. to 1 V/div.
n/a
DC-offset
± 0.2V to ± 50V
± 0.2V to ± 100V
–
Component tester
–
■
Probes included
(Amount = number of channels)
HZ355
HZ350
HMO compact series
HZ350
HZO10
1 MΩ
HZO10
HZ154
Logic probe HO3508 | HO3516
Carrying case HZO90 | HZ99
❙ Logic probe HO3508 fits to all HMO series oscilloscopes (also available as double pack HO3516)
❙ No hardware lock to a specific device
❙ 8 logic channels available on each logic probe
❙ Signal threshold adjustable for each logic pod
The HZO90 (HMO3000 series, HMS series) or HZ99 (HMO compact series) carrying case allows you to
conveniently and safely transport
your instrument.
HZ154
More informationen | www.hameg.com 3
Spectrum Analyzers
HMS-X Spectrum Analyzer
1 Basic Unit + 3 Options =
Your HMS Spectrum Analyzer
Key facts
❙ Frequency range: 100 kHz to 1.6 GHz/3 GHz*1
❙ Spectral purity greater than -100 dBc/Hz (at 100 kHz)
❙ SWEEP from 20 ms to 1000 s
❙ Detectors: auto-, min-/max.-peak, sample, RMS, average, quasi-peak*2
❙ Miscellaneous marker/Δmarker and peak functions
❙ Tracking generator*3
Frequency range: 5 MHz to 1.6 GHz/3 GHz*1
Output level: -20 dBm to 0 dBm
❙ Directly export data to USB flash drive, RS-232/USB dual interface for remote control
❙ Fanless design and fast boot time
*1
with HMS-3G (HV212) option
with HMS-EMC (HV213) option
*3
with HMS-TG (HV211) option
*2
HMS-X options
One HMS-X basic unit and three options allow you to
configure an instrument that best fits your needs
HMS-TG
HMS-3G
his option activates the tracking generator in the T
instrument.
The frequency range is increased from 1.6 GHz to 3 GHz with this option.
Option code*4
Voucher code*5
Unlock built-in tracking generator HMS-TG
HV211
Bandwidth upgrade to 3 GHz
HMS-3G
HV212
EMC option incl. preamplifier
HMS-EMC
HV213
*4
*5
available only with purchase of HMS-X basic unit
activate HMS-X options at any time after purchase of HMS-X basic unit
You can easily upgrade all three available options at any later
point in time with option upgrade vouchers available at your
dealer. The voucher number and the serial number of your HMS-X instrument enable you to generate the respective
licence key directly on a dedicated web page.
HMS-EMC This option activates all the functions that are required for EMC precompliance measurements. The preamplifier option has been integrated into the new HMS EMC option.
In response to customer feedback, the preamplifier function, which was previously available separately with the HMS-X,
has become an integral part of the HMS-EMC option (HV213 as voucher). It is therefore no longer necessary to purchase this separately.
HMS-X series model overview
HMS-X with EMC option
HMS-X basic unit
Amplitude measurement range
-114 dBm to +20 dBm
-104 dBm to +20 dBm
DANL
typ. -135 dBm
typ. -104 dBm
Resolution bandwidth
100 Hz to 1 MHz, 200 kHz (-3 dB), 200 Hz, 9 kHz, 120 kHz, 1 MHz (-6 dB)
10 Hz to 1 MHz
10 kHz to 1 MHz, 200 kHz (-3 dB)
Video bandwidth
4 HAMEG INSTRUMENTS | Product Overview
1 kHz to 1 MHz
Spectrum Analyzers
VSWR bridge 3 GHz HZ547
Frequency range:
100 kHz to 3 GHz
This unit is used to measure the voltage standing wave ratio (VSWR) and reflection coefficient of a device under test with an impedance of 50 Ω.
Impedance:
50 Ω
Directivity:
28 dB (100 kHz to 300 kHz)
>
>35 dB (300 kHz to 1 GHz)
>30 dB (1 GHz to 3 GHz)
>20 dB
Reflection loss at DUT port:
Insertion loss
❙ Option HMS-TG required
❙ Option HMS-3G recommended
IN ▷ OUT:
20 dB (100 kHz to 300 kHz)
IN ▷ OUT:
18 dB (300 kHz to 3 GHz)
IN ▷ DUT:
1.7 dB
DUT ▷ OUT:
16 dB
Max. Power Dissipation:
+26 dBm
Connectors:
N (female)
Accessories supplied: HZ525 (termination 50 Ω 1 W), N male to N male (2 pcs.), carrying case
Near-field probe set 3 GHz HZ540 | HZ550
Near-field probe set 1 GHz HZ530
Near-field probe set for comparative measurements with built-in preamplifier covering frequency ranges from 1 MHz to 3 GHz, designed for the 50 Ω N-connectors of the HMS-X:
❙ E-field probe
❙ H-field probe
❙ High impedance probe
❙ µH-field probe (HZ550)
❙ Radiation probe (HZ550)
Three active broadband probes, designed for 50 Ω inputs of HMS-X, powered either by the analyzer or by batteries:
❙ E-field probe
❙ H-field probe
❙ High impedance probe
Two-line V-network (LISN)
HM6050-2
Alternative version
HZ540L | HZ550L
❙ Single-phase V-network to measure line-conducted interferences from 9 kHz to 30 MHz (based on CISPR 16)
❙ 115 V and 230 V versions available
❙ Selectable transient limiter
❙ Artificial hand connector
❙ RS-232 interface for remote control
Same specification as HZ540 | HZ550, but with low
capacitance probe instead of
high impedance probe
EMC precompliance set 1 GHz HMS-SET1
The EMC precompliance set HMS-SET1 includes all necessary instruments to analyse typical EMC problems. This set contains a spectrum analyzer HMS-X incl. HMS-EMC option, a probe set HZ530, the HM6050-2 LISN for line conducted measurements and the HMExplorer software for EMC precompliance measurements.
+
+
HM6050-2
HZ530 1GHz
HMS-X incl. HMS-EMC option
EMC precompliance set 3 GHz HMS-SET2
The EMC precompliance set HMS-SET2 includes all necessary instruments to analyse typical EMC problems. This set contains a spectrum analyzer HMS-X incl. HMS-EMC and HMS-3G option, a probe set HZ540, the HM6050-2 LISN for line conducted measurements and the HMExplorer software for EMC precompliance measurements.
+
HMS-X incl. HMS-EMC and HMS-3G option
+
HZ540 3 GHz
HM6050-2
More informationen | www.hameg.com 5
Power Supplies
HMP Power Supplies
Programmable 3 or 4-Channel
High-Performance Power Supplies
HMP4030 | HMP4040
Key facts
❙ Low residual ripple due to linear post-regulators
❙ Real-time voltage, current and watt values
❙ High setting and read-back resolution: 1 mV and 0.1 / 0.2 / 1.0 mA (current output and model dependent)
❙ FuseLink (electronic fuse) freely combinable for all channels
❙ FuseDelay tuneable up to 250 ms
❙ EasyArb function directly programmable at the device
❙ PC software (free of charge) to easily generate user-defined waveforms
❙ Independently adjustable over-voltage protection (OVP) for each channel
❙ Advanced parallel- and serial operation through V/I tracking
❙ Front connectors: 4 mm safety sockets
❙ Rear connectors for all channels including SENSE
❙ RS-232/USB dual interface, remote control via SCPI based commands
HMP series model overview
HMP4040
Output voltage per channel
0 V to 32 V
Output current per channel
HMP4030
HMP2030
HMP2020
0 A to 10 A
0 A to 5 A
Maximum output power per channel
160 W
80 W
1 x 0 A to 10 A
1 x 0 A to 5 A
1 x 160 W
1 x 80 W
Total output power
384 W
Channels
4
188 W
3
3
2
Industrial production environment
Power supply units in industrial production environment are
often found in 19” racks. The HMP series instruments are very suitable for this use as all models can be integrated into
19” racks with the rack mounting kits HZ42 (for HMP20x0 instruments) and HZP91 (for HMP40x0 instruments). Additionally, all front panel connectors, including SENSE lines, are also located at the back panel of the instrument. And last but not least, the existing USB and serial connector card (HO720) in all HMP models can alternatively be replaced
by an Ethernet/USB (HO730) or GPIB card (HO740) for remote control capability purposes.
19” rackmount kit HZP91
Rear connectors for all channels including SENSE
6 HAMEG INSTRUMENTS | Product Overview
Power Supplies
Programmable 2 or 3-Channel
High-Performance Power Supplies
HMP2020 | HMP2030
HMP2020 with one 160 W channel
3-Channel Arbitrary Power Supply
HM8143
3-Channel Power Supply
HM7042-5
Key facts
❙ 2 x 0 V to 30 V/0 A to 2 A | 1 x 5 V/2 A | (130 W)
❙ Linear regulated, two-quadrant power supply (current source and sink)
❙ Real-time voltage and current values
❙ Setting and read-back resolution: 10 mV / 1 mA
❙ Advanced parallel- and serial operation
❙ Front connectors: 4 mm safety sockets
❙ SENSE connectors for line loss compensation (30 V channels)
❙ External modulation of output voltages up to 50 kHz
❙ Arbitrary module: 4096 points, 12 bit
❙ PC software (free of charge) to easily create user-defined waveforms
❙ RS-232/USB dual interface, IEEE-488 (GPIB) optional
Key facts
❙
❙
❙
❙
❙
❙
❙
❙
2 x 0 V to 32 V / 0 A to 2 A | 1 x 0 V to 5.5 V / 0 A to 5 A | (155 W)
Low residual ripple due to linear post-regulators
Real-time voltage and current values
Setting and read-back resolution: 10 mV / 1 mA
Advanced parallel- and serial operation
Adjustable over-voltage protection (OVP)
Front connectors: 4 mm safety sockets
Temperature-controlled fan management
More informationen | www.hameg.com 7
Function Generator | HMC Compact Series
HMF Arbitrary Function Generator
25 MHz | 50 MHz Arbitrary Function Generator
HMF2525 | HMF2550
Key facts
❙
❙
❙
❙
❙
❙
❙
❙
❙
❙
❙
Frequency range: 10 µHz to 25 MHz /50 MHz
Triangle waveforms up to 10 MHz
Output voltage: 5 mVpp to 10 Vpp (at 50 Ω)
Waveform modes: sine, square, triangle/ramp, pulse and
arbitrary waveforms (incl. predefined waveforms as white/
pink noise, cardinal sine, exponential rise/fall, et al.)
Modulation modes: AM, FM, pulse, PWM, FSK (internal and external)
Arbitrary waveform generator: 250 MSa/s, 14 bit, 256 kPts
PC software (free of charge) to easily create user-defined waveforms
Oscillographic signal display in real-time
Front USB connector to easily save and recall waveforms and settings
RS-232/USB dual interface for remote control
Fanless design
HMC Compact Series
5 ¾-Digit Digital Multimeter
HMC8012 | HMC8012-G
Key facts
❙
❙
❙
❙
❙
❙
❙
❙
❙
❙
❙
Measurement range: DC to 100 kHz Resolution: 1 μV, 100 nA, 1 mΩ, 1 pF, 1 Hz, 0.1 °C/F
Basic accuracy: 0.015 % (DC)
True RMS measurement, AC and AC+DC
Simultaneous display of three measurement functions,
e.g. DC + AC + statistics
Measurement rate: up to 200 values per second
Measurement functions: VDC, IDC, RMS, VAC, IAC, frequency, DC power, resistance (2- and 4-wire), temperature, capacitance,
diode and continuity test
Mathematic functions: limit testing, Min/Max, average, offset, DC power, dB, dBm
Data logging to internal memory or USB flash drive in .csv-format
Interfaces: USB-TMC/-VCP, Ethernet, LXI, IEEE-488 (GPIB)*
SCPI commands widely compatible with Agilent 34410A
*HMC8012-G only
8 HAMEG INSTRUMENTS | Product Overview
LCR Bridge
LCR Bridge
LCR Bridge
HM8118
Key facts
❙
❙
❙
❙
❙
❙
❙
❙
❙
Measurement range: 20 Hz to 200 kHz (69 steps)
Basic accuracy: 0.05 %
Measurement rate: up to 12 values per second
Automatic or manual selection of circuit type (serial, parallel)
Measurement functions:
L, C, R, |Z|, X, |Y|, G, B, D, Q, Θ, Δ, M, N
Transformer measurement: mutual inductance and ratio
Tunable DC BIAS (voltage / current): internal: 0 V to 5 V / 0 mA to 200 mA (resolution: 10 mV / 1 mA)
external: 0 V to 40 V (voltage BIAS only)
RS-232/USB dual interface for remote control
Fanless design
19” rackmount kit HZ42
HZ184 + HZ188 included
Due to its remote control capability the HM8118 is regularly used in industrial production environments.
The HM8118 includes a 4-wire SMD component test fixture (HZ188) as well as a 4-wire Kelvin test cable (HZ184).
4-wire test fixture incl. shorting plate HZ181
4-wire transformer test cable HZ186
This optional 4-wire test fixture is for evaluation of your leaded components, incl. shorting plate.
The HZ186 is an optional 4-wire transformer test cable to measure the mutual inductance and ratio.
More informationen | www.hameg.com 9
System Devices
System Devices
RF-Synthesizer 3 GHz
HM8135 | HM8135-X
Key facts
❙ Frequency range: 1 Hz to 3 GHz
❙ High dynamic output power:
-135 dBm to +13 dBm
❙ Frequency resolution: 1 Hz
❙ High spectral purity, excellent SWEEP mode
❙ Modulation modes: AM, FM, pulse, phase, FSK, PSK
❙ Internal modulation (10 Hz to 200 kHz): sine, square, triangle, ramp
❙ External Ref.-Input/Output (10 MHz) via BNC-connector
❙ HM8135:
TCXO (temperature stability: ±0.5 x 10-6)
HM8135-X: OCXO (temperature stability: ±1.0 x 10-8)
❙ RS-232/USB dual interface, IEEE-488 (GPIB) optional
RF-Synthesizer 1.2 GHz
HM8134-3 | HM8134-3X
Key facts
Programmable Counter 3 GHz
HM8123 | HM8123-X
Key facts
10 HAMEG INSTRUMENTS | Product Overview
❙
❙
❙
❙
❙
❙
Frequency range: 1 Hz to 1.2 GHz
High dynamic output power: -127 dBm to +13 dBm
Frequency resolution: 1 Hz
High spectral purity, excellent SWEEP mode
Modulation modes: AM, FM, pulse, phase, FSK, PSK
Internal modulation (10 Hz to 150 kHz ): sine, square, triangle, ramp
❙ External Ref.-Input/Output (10MHz) via BNC-connector
❙ HM8134-3: TCXO (temperature stability: ±0.5 x 10-6)
HM8134-3X: OCXO (temperature stability: ±1.0 x 10-8)
❙ RS-232/USB dual interface, IEEE-488 (GPIB) optional
❙ Measurement range: DC to 3 GHz
Input A/B (BNC): DC to 200 MHz Input C (SMA): 100 MHz to 3 GHz
❙ Input impedance A/B: 50 Ω or 1 MΩ (switchable), sensitivity 25 mV
Input impedance C: 50 Ω, sensitivity 30 mV
❙ 10-digit resolution (at 10 s gate time)
❙ 9 measurement functions, external GATE and ARMING connectors (BNC)
❙ External Ref.-Input (10 MHz) via BNC-connector
❙ HM8123: TCXO (temperature stability: ±0.5 x 10-6)
HM8123-X: OCXO (temperature stability: ±1 x 10-8)
System Devices
6 ½-Digit Precision Multimeter
HM8112-3 | HM8112-3S
Key facts
❙
❙
❙
❙
❙
❙
❙
❙
❙
Arbitrary Function Generator 12.5 MHz
HM8150
Key facts
❙
❙
❙
❙
❙
❙
❙
❙
❙
Power Consumption Meter 8 kW
HM8115-2
Measurement range: DC to 300 kHz
Resolution: 100 nV, 100 pA, 100 µΩ, 0.01°C/F
High accuracy: 0.003 % (DC), 0.08 % (AC)
True RMS measurement, AC and AC+DC
Measurement functions: voltage, current, resistance and
temperature measurement, frequency and diode test
(2- and 4-wire)
Measurement intervals from 0.1 s to 60 s
Internal data logger for long-term acquisition RS-232/USB dual interface, IEEE-488 (GPIB) optional
HM8112-3S: HM8112-3 with scanner card
Frequency range: 10 mHz to 12.5 MHz
Triangle waveforms up to 250 kHz
Output voltage: 10 mVpp to 10 Vpp (at 50 Ω)
Waveform modes: sine, square, triangle/ramp, pulse and
arbitrary waveforms
External amplitude modulation up to 20 kHz
External connectors: GATE (I), TRIGGER (I/O), SWEEP (O), MODUALTION (I)
Arbitrary waveform generator: 40 MSa/s, 12 bit, 4096 Pts
PC software (free of charge) to easily create user-defined waveforms
RS-232/USB dual interface, IEEE-488 (GPIB) optional
Key facts
❙
❙
❙
❙
❙
❙
❙
❙
❙
Measurement range: 1 mW to 8 kW
Voltages from 100 mV to 500 V, currents from 1 mA to 16 A
Frequency range: DC to 1 kHz
Simultaneous display of voltage, current and power
(W, var, VA or power factor) values
Auto-ranging for easy measurement
Suitable for measurements on frequency converters
MONITOR (BNC) shows instantaneous power value
RS-232/USB dual interface, IEEE-488 (GPIB) optional
PC software (free of charge) for automated long-term data acquisition included
Power adapter HZ815
Adapter (10 A fused) for easy measurement of mains voltage,
current and power consumption
to use with HM8115-2
More informationen | www.hameg.com 11
Modular System
Modular System Series 8000
Mainframe
HM8001-2
Key facts
❙ Basic unit for modules of the modular system series 8000
❙ Power supply for 2 modules
❙ DC voltages electronically regulated, floating and short-circuit proof
❙ Power transformer with thermal fuse
❙ Up to 5 mainframes can be stacked
4 BNC connectors option HO801
4 BNC connectors on the rear panel of the HM8001-2 allow signal
transmission to or from HM8021-4
and HM8030-6 modules
4 ¾-Digit Programmable
Multimeter
HM8012
LCR Meter
HM8018
Universal Counter 1.6 GHz
HM8021-4
Function Generator 10 MHz
HM8030-6
Tripple Power Supply
HM8040-3
Blank Module
HM800
12 HAMEG INSTRUMENTS | Product Overview
Key facts
❙
❙
❙
❙
4 ¾-digit display with 50,000 counts
Basic accuracy 0.05 %
Max. resolution: 10 µV, 0.01 dBm, 10 nA, 10 mΩ, 0.1 °C
Offset function/relative value measurement
Key facts
❙ Measurement functions: L, C, R, Θ, Q/D, |Z| ❙ Basic accuracy 0.2 %
❙ 5 measurement frequencies:
100 Hz, 120 Hz, 1 kHz, 10 kHz, 25 kHz
Key facts
❙ Measurement range 0 Hz to 1.6 GHz
❙ 10 MHz time base with 1 ppm stability (TCXO)
❙ Input A: input impedance 1 MΩ, sensitivity 20 mVrms
Input C: input impedance 50 Ω, sensitivity 30 mVrms
8-digit resolution for 10 s measuring time
Key facts
❙ Frequency range 50 mHz to10 MHz,
output voltage up to 10 Vpp (into 50 Ω)
❙ Waveforms: sine wave, triangle, square wave, pulse, DC
❙ Distortion factor <0.5 % up to 1 MHz, rise and fall time typ. 15 ns
Key facts
❙ 2 x 0 to 20 V/0.5 A | 1 x 5 V/1 A
❙ 3-digit switchable displays (display resolution 0.1 V/1 mA)
❙ Pushbutton to activate / deactivate all outputs
Key facts
❙ Module for customized instrument construction
❙ Guide rails for mounting circuit boards at 4 different levels
❙ Plastic front panel for easy mechanical processing
Accessories
High voltage probe HZO20
1GHz active probe HZO30
Attenuation ratio:
1,000:1
Attenuation ratio:
10:1
Bandwidth:
400 MHz
Bandwidth:
1 GHz
Input impedance:
50 MΩ II 7.5 pF
Input impedance:
1 MΩ II 0.9 pF
Max. voltage:
1,000 Vrms
Max. voltage:
20 V
Active differential probes HZO40 | HZO41
Active differential high voltage probe HZ115
HZO40
HZO41
Differential input voltage (ACrms):
1,000 V
Attenuation ratio:
10:1
10:1
Attenuation ratio:
100:1 / 1,000:1
Bandwidth:
200 MHz
800 MHz
Bandwidth:
20 / 30 MHz
Gain accuracy:
±1 %
±2 %
Input impedance:
60 MΩ II 1.5 pF
Max. input voltage per input:
±60 V
±40 V
Input impedance between inputs:
1 MΩ II 3.5 pF
200 kΩ II 1 pF
CMRR (typical):
-80 dB at 60 Hz
-50 dB at 10 MHz
9 V battery 6LR61
-60 dB at 60 Hz
-15 dB at 500 MHz
9 V battery 6LR61
Battery operation:
19” rackmount kits (width 482 mm)
HZ42 | HZ43 | HZ46 | HZC95 | HZO91 | HZP91
HZ42 (2RU / 88 mm*):
Instrument height 75 mm (for Series 8100, HM8143, HM7042-5, HM8001-2, HMP2020, HMP2030 and HMF series)
HZC95 (2RU / 88 mm*):
Instrument height 88 mm (for HMC8012) HZ43 (3RU / 132.5 mm*):
Instrument height 125 mm (for HM6050-2) HZ46 (4RU / 177 mm*):
Instrument height 175 mm (for HMO series 3000 and HMS series) HZO91 (4RU / 177 mm*):
Instrument height 175 mm (for HMO72X, HMO102X, HMO152X, HMO202X) HZP91 (4RU / 177 mm*):
Instrument height 125 mm (for HMP4030, HMP4040) *plus excess of the instrument HZO40
HZO41
HZ42
HZC95
HZ43
HZ46
HZO91
HZP91
AC/DC current probes HZO50 | HZO51
HZO50
HZO51
Measurement range:
±20 Arms /30 Ap
±100 Arms / 1,000 Arms
Accuracy:
±1 % / ±2 mA
±1 % / ±0.1 A / ±0.5 A
Bandwidth:
DC to 100 kHz (0.5 dB)
DC to 20 kHz
Max. voltage:
300 Vrms (AC or DC)
300 Vrms (AC or DC)
Ethernet/USB dual interface card HO730
IEEE-488 (GPIB) interface card HO740
❙ Ethernet 10/100 MBit/s with integrated webserver
❙ 24-pin connection in accordance with IEEE-488 (GPIB)
❙ Remote control via browser interface
❙ USB 2.0, Type B connector
❙ Galvanic separation of measurement device and
interface
❙ For all devices of HMF, HMO, HMP and HMS series
❙ For all devices of HMF, HMO, HMP and HMS series
More informationen | www.hameg.com 13
From entry level to high
performance.
Oscilloscopes from the
T&M expert.
Fast operation, easy to use, precise measurements – that’s Rohde & Schwarz oscilloscopes.
R&S®RTO: high performance (Bandwidths: 600 MHz to 4 GHz)
The high-end R&S®RTO features excellent signal fidelity, fast acquisition rates and impressive
analysis options.
R&S®RTM: upper midrange (Bandwidths: 350 MHz and 500 MHz)
Ever wished for a better bench scope? The R&S®RTM with its deep memory, high acquisition
rate and large high-resolution XGA display offers the best performance in its class.
HMO3000: midrange (Bandwidths: 300 MHz to 500 MHz)
A solid performer, the HMO3000 oscilloscope has outstanding measurement characteristics
and useful functions.
HMO: entry level (Bandwidths: 70 MHz to 200 MHz)
The HMO scopes offer dependable technology and compact dimensions at an attractive price.
All Rohde & Schwarz oscilloscopes incorporate time domain, logic, protocol and frequency
analysis in a single device.
Take the dive at www.scope-of-the-art.com/ad/all
value-instruments.com
#HAMEGcom
www.hameg.com
HAMEG Instruments GmbH
Industriestr. 6 | 63533 Mainhausen | Germany
Phone +49 (0) 6182 8000
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG
HAMEG Instruments® is a registered trademark of HAMEG Instruments GmbH | Trade names are trademarks of the owners
11 / 2013 | © HAMEG Instruments GmbH | 4A-D000-428
Printed in Germany | Subject to change without notice
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement