1 NOTICE INVITING TENDER (Section – I)

1 NOTICE INVITING TENDER (Section – I)
Price Rs. 2000/- only
F.NO.(24) (26)/UCMS/CS/OGT/Scientific Equipment/2015-16
Dated: 23.11.2015
UNIVERSITY COLLEGE OF MEDICAL SCIENCES
(UNIVERSITY OF DELHI)
& GURU TEG BAHADUR HOSPITAL
DILSHAD GARDEN, DELHI – 110 095
COLLEGE: 0091-11-22582972-74
FAX: 0091-11-22590495
WEBSITE: http://www.ucms.ac.in
NOTICE INVITING TENDER
(Section – I)
On behalf of the Principal, UCMS, the undersigned is directed to invite the sealed
tenders from registered manufacturers/authorised suppliers on DDP basis (Delivered Duty Paid)
for the supply & installation of following items:Tender Group
Anatomy
Physiology
Community
Medicine
MRU
Patho – Histo
Patho – Hemato
Pathology – TT
Patho – Cyto
Biochemistry
Forensic Medicine
MIU
Micro
Name of the Items (Detailed Specifications are given in Section IV of the Tender
Document)
Embalming Machine
Perimeter, Mosso’s Erogograph, Pulmonary Function Testing machine with diffusion
and body plethysmography,
Ice Lined Refrigerator (ILR)
Liquid Nitrogen Container, Autoclave, Vacuum Pump for Media Filtration & Solid
Phase Extraction (SPE), Centrifuge Machine, Gas Chromatography – Mass
Spectrometer, UV-VIS Double beam Spectrophotometer with temperature control and
data management system, Atomic Absorption spectrophotometer with fume hood,
Semi – Micro Weighing Balance, Inverted Microscope with phase Contrast and CCD
0
Camera, Refrigerated Out – swing Centrifuge, -150 C Deep Freezer
Slide Warming Plate, Slide Filing Cabinet, Orbital Shaker (Non-incubated), Gross
Station, Waste Tray for Manual Rotary Microtome, Block Filing Cabinet, Automated
Tissue Processor with Fume Control Bench Top, Tissue Flotation Bath, Spectrum Gold
Filter for existing Upright Trinocular Research Fluorescent Microscope with Digital
Image Analysis system, Electrically operated glass etching hand held tool,
Ultrapure Type I Water Purification System, Fully automated microplate ELISA Reader
with printer, Projection System for 7 Headed teaching Microscope
Upright LED microscope with imaging system
PH/ORP probe with Liquid gel and polymer electrolyte, Incubator (Table Top), Antigen
Retrieval System
Semi-Autoanalyser, Micro-Centrifuge, Gradient Thermal Cycler
Height Weight Machine, Human Bone (Adult & Original), X-Ray View Box, Digital
Weighing Balance
Plotter Printer, Photo Printer/Photo Inkjet Printer
Fluorescent Trinocular Microscope, Brightfeild Trinocular Microscope, Refrigerator
Double Door, Binocular Microscope, B.O.D Incubator, Microwave Oven, Vertical
Autoclave, VDRL Shaker Digital, Water Bath, Clinical Centrifuge Table Top,
Inspissator, Egg Incubator
1
The Tender Document for items will be on TWO BID System consisting of Technical
Bid and Price Bid. The bid(s) has to be submitted item-wise (separate bid for each item,
failing which, the bid shall not be opened/entertained) containing two parts, Part-I as
Technical Bid in one sealed envelope and Part-II as Price Bid in one sealed envelope. Both the
sealed envelopes (for Technical as well as Price Bid) must be put in one big envelope and on all
the three envelopes must be clearly mentioned all details of item (Tender Group, Name of Item,
Tender No., Name & address alongwith mobile number of Bidder etc.). Any bidder may bid for
any number of items against the purchase of single Tender Document but each offer must be
submitted itemwise in two bid system. Separate EMD must be enclosed with the Technical
Bid for each item.
The Tender Documents along with detailed specifications, terms and conditions can be
downloaded from the College web site “http://www.ucms.ac.in/tender.htm” and the fee for tender
documents of Rs.2000/- (Rupees two thousand only) must be enclosed with the technical bid.
Tender document fee is not refundable. NAME & ADDRESS OF BIDDER ALONGWITH THE
TENDER GROUP & NAME OF ITEM MUST BE MENTIONED ON THE BACKSIDE OF
DEMAND DRAFTS. THE BIDDER CAN PARTICIPATE FOR ANY NO. OF ITEMS AGAINST
THE SINGLE TENDER DOCUMENT FEE.
a)
b)
c)
d)
e)
f)
g)
Price of Tender Document: Rs.2000/- (Two Thousand only) Non-refundable.
Date of commencement of sale of Tender Document: 23.11.2015.
Last date and time for receipt of Tender Document: 15.12.2015 up to 3:00 p.m.
The tender should be addressed to “The Principal, University College of
Medical Sciences, Dilshad Garden, Delhi-110095” and may be dropped in
tender box kept in the office of Sh. Rajesh Kumar, Asstt. Registrar (Central
Stores), Room No. 11, Ground Floor, UCMS or sent by registered post so as to
reach the College on/before 15.12.2015 up to 3:00 Hrs. No tender will be accepted
after due date and time.
Time and date of opening of Technical Bid: 16.12.2015 from 10.30 a.m. onwards.
In case demonstration is required for any item(s), the Price Bids for such item(s)
shall be opened after the demonstration.
If any further amendment / changes made by the College, the same will be
uploaded on College website only.
Tender should be submitted separately for each item.
All Tender Documents must be accompanied with the Earnest Money Deposit
(Refundable without interest), failing which the bid will be rejected. The Earnest Money Deposit
is to be paid in the form of Demand Draft / Pay Order only in favour of “The Principal,
University College of Medical Sciences” payable at Delhi and should be attached with
Technical Bid. Name of firm and complete postal address of bidder alongwith the Tender Group
& Name of item must be mentioned on the backside of Demand Drafts.
The College shall not be responsible for any delay in receiving bids/sending of
Tender Document by post.
The College reserves the right to accept or reject or cancel any bid/item at any stage
of procurement process without assigning any reason thereof. No correspondence in this
regard shall be entertained.
Earnest Money shall be forfeited in case, it is found, at any stage that
information/particulars regarding supply of tendered item(s) are false.
(S. K. DOGRA)
DEPUTY REGISTRAR
2
SECTION II.
INSTRUCTIONS TO BIDDERS
A. Introduction
1. Eligible Bidders/Tenderer
1.1
This invitation for bids is open to all reputed manufacturers or their sole
authorised dealer (wherever manufacturers are not directly selling their
product).
1.2
Tenderer/Bidder should not be under a declaration of ineligibility for corrupt
and fraudulent practices issued by any Government Office.
2. Cost of Tender/Bidding:
2.1
The Bidder shall bear all costs associated with the preparation and submission
of its bid, and the University College of Medical Sciences hereinafter referred
to as “the purchaser”, will in no case be responsible or liable for those costs,
regardless of the conduct or outcome of the bidding process.
B.
The Tender/Bidding Documents
3. Content of Tender/Bidding Documents
3.1
The goods required, bidding procedures and contract terms are prescribed in
the bidding documents. In addition to the invitation for bids, the bidding
documents include:
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
l)
m)
n)
3.2
Tender Notice
Instructions to Bidders.
General Conditions of Contract;
Technical Specifications;
Schedule of Requirements;
Qualification Requirement;
Tender/Bid Form and Price Schedules;
Tender/Bid Security Form (Earnest Money form)
Contract Form;
Performance Security Form;
Performance Statement;
Manufacturer’s Authorization Form;
Capability Statement Forms; and
Service Support Details Form
The Tenderer/Bidder is expected to examine all instructions, forms, terms and
specifications in the bidding documents. Failure to furnish all information
required in the bidding documents or submission of a bid not substantially
responsive to the bidding documents in every respect will be at the
Tenderer’s/Bidder’s risk and may result in the rejection of its bid.
-3-
4. Clarification of Tender/Bidding Documents;
4.1
A prospective Tenderer/Bidder requiring any clarification of the
Tender/Bidding Documents may notify the purchaser in writing at the
purchaser’s mailing address indicated in the invitation for Tender/Bids, which
must be received before 10 days from the last date of submission the bid
5. Amendment of Tender/Bidding Documents;
5.1
At any time prior to the deadline for submission of bids, the purchaser may,
for any reason, whether at its initiative or in response to a clarification
requested by a prospective bidder, modify the bidding documents by
amendment.
5.2
All prospective bidders should keep in touch to the College website for any
further amendments / changes and shall be binding on them.
5.3
In order to allow prospective bidders reasonable time in which to take the
amendment into account in preparing their bids, the purchaser may, at its
discretion, extend the deadline for the submission of bids.
C. Preparation of Bids/Tenders
6. Language of Bids/Tenders:
6.1
The Tenders/Bids prepared by the Tenderer/Bidder, as well as all
correspondence and documents relating to the Tender/Bid exchanged by the
Tenderer/Bidder and the purchaser, shall be written in English/Hindi language.
Supporting documents and printed literature shall also be furnished in English.
7. Documents Comprising the Bid/Tender:
7.1
The Tender/ Bid prepared by the Tenderer/Bidder shall comprise the following
components:
a)
b)
A Tender/Bid Form and a price schedule.
Documentary evidence establishing that the Tenderer/bidder is eligible to
Tender/Bid and is qualified to perform the contract if its Tender/Bid is
accepted;
Documentary evidence establishing goods eligibility and conformity to
bidding documents.
In case of authorised agent, the Authorisation Certificate, issued by the
Principal firm.
Earnest Money Deposit.
Copy of Registration Certificate of Sale Tax/DVAT etc.
c)
d)
e)
f)
7.2
The Tenders/Bids so prepared shall be submitted in two sealed envelopes in
two parts as follows:
-4-
Part I.
Technical Bid
Containing unpriced Bid consisting of complete technical package and
unpriced commercial package including Bid Form duly filled and signed. No price
detail is to be given in this bid. NO ALTERNATE OFFER (FOR OTHER
MODELS) SHALL BE ALLOWED, OTHERWISE, THE BID MAY BE
TECHNICALLY REJECTED.
Blank Price Schedule Format (Columns 1 to 4 only filled in) as submitted in
Section VII (1) shall also be enclosed.
Part II.
Price Bid
Containing prices, with detailed break up as per format enclosed, both in
figures and in words. Authenticated copy of manufacturers rate list / prices be
enclosed for justification of prices quoted to the College.
Item wise Technical Bid & Price Bid is to be submitted in separate envelopes.
Enclose separate EMD with Technical Bid for each item separately.
8. Tender/Bid Form:
The Tenderer/Bidder shall complete the bid form.
8.1
9. Tender/Bid Prices

If rates are quoted in foreign currency, the rates must be on DDP (Delivered Duty
Paid) basis including insurance of the item.
“Delivered Duty Paid” means that the seller delivers the goods when the goods
are placed at the disposal of the buyer, cleared for import on the arriving means
of transport ready for unloading at the named place of destination. The seller
bears all the costs and risks involved in bringing the goods to the place of
destination and has an obligation to clear the goods not only for export bus also
for import, to pay any duty for both export and import and to carry out all customs
formalities.

9.1
However, the custom clearance documents will be provided by the purchaser at
the time of clearing the item. It includes Custom Duty Exemption Certificate
(CERTIFICATE FOR AVAILING CUSTOMS DUTY EXEMPTION IN TERMS
OF GOVT. NOTIFICATION NO.51/96-CUSTOM DATED 23RD JULY, 1996
AND CENTRAL EXCISE DUTY EXEMPTION IN TERMS OF GOVT.
NOTIFICATION NO.10/97-CENTRAL EXCISE DATED 01ST MARCH, 1997),
authorization letters, Bank Release Order etc.
The Tender/Bidder shall indicate on the price schedule the unit prices and total
bid prices of the goods it proposes to supply under the contract for each item
separately. In any column does not apply to the bidder, same should be
mentioned as NOT APPLICABLE.
-5-
9.2
The Tenderer/Bidder’s separation of price components will be solely for the
purpose of facilitating the comparison of bids by the purchaser and will not in
any way limit the purchaser’s right to contract on any of the terms offered.
9.3
Fixed price: Prices quoted by the Tenderer/Bidder shall be fixed during the
Tenderer/Bidder’s performance of the Contract and not subject to variation on
any account. A bid submitted with an adjustable price quotation will be treated
as non-responsive and rejected.
10
Tender/Bid currencies;
10.1
Prices may be quoted in Indian National Rupees (INR) on FOR
(Destination of purchaser) basis. In case of items priced in foreign
currencies, converted INR value should be given on the publication date
of NIT and it must be on DDP (Delivered Duty Paid, please refer point
No.9) basis.
11
Documents Establishing Tender/bidder’s Eligibility and Qualifications;
11.1
The Bidder shall furnish, as part of its bid, documents establishing the
Tenderer/bidder’s eligibility to bid and its qualifications to perform the
contract if its bid is accepted.
11.2
The documentary evidence of the bidder’s qualifications to perform the
contract if its bid is accepted, shall be established to the purchaser’s
satisfaction:
a)
That, in the case of a bidder offering to supply goods under the contract
which the Bidder did not manufacture or otherwise produce, the Bidder
has been duly authorized (AS PER AUTHORISATION FORM IN
SECTION XII) by the goods manufacturer or producer to supply the goods
in India.
b)
That Bidder has the financial, technical and production capability
necessary to perform the contract and meet the criteria outlined in the
QUALIFICATION REQUIREMENTS SPECIFIED IN SECTION VI.
c)
If an Agent submits bids on behalf of more than one MANUFACTURER,
unless each such Bid is accompanied by a Separate TENDER/BID FORM
for each Tender/Bid and a separate EMD, when required for each Bid and
AUTHORISATION from the respective Manufacturer, all such Bids will
be rejected as non-responsive.
d)
The Tenderer/Bidder should have preferably executed similar single
supply order of atleast to the extent of 10 times of the items being quoted.
Copies of previous Purchase Order(s) for the same item issued by any
Govt. organisation may be provided, if required by Purchaser.
-6-
e)
Income Tax Clearing Certificate for last three years.
12
Documents Establishing Goods
Tendering/Bidding Documents:
12.1
The Tenderer/Bidder shall furnish, as part of its Tender/Bid, documents
establishing the eligibility and conformity to the bidding documents of all
goods and services, which the Tenderer/Bidder proposes to supply under the
contract.
12.2
The documentary evidence of conformity of the goods and services to the
Tendering/Bidding documents may be in the form of literature, drawings and
data, and shall furnish:
A detailed description of goods essential technical and performance
characteristics of the goods;
A list giving full particulars, including available sources of all spare parts,
special tools, etc. necessary for the proper and continuing functioning of
the goods for a period of six years, following commencement of the goods
used by the purchaser;
An item-by-item commentary on the purchaser’s technical specifications
demonstrating the goods and services substantial responsiveness to those
specifications or a statement of deviations and exceptions to the provisions
of the technical specifications.
A confirmation that if the Tenderer/Bidder offers system and/or other
software manufactured by another company, such software operates
effectively on the systems offered by the Bidder; and the Tenderer/Bidder
is willing to accept responsibility for its successful operation; and
A confirmation that the firm has already achieved ISO 9002 Certification
system. Necessary Certification of ISO 9002 should be attached if
applicable.
Copy of Registration Certificate/Certificate of incorporation (as per the
applicable law) may be enclosed.
a)
b)
c)
d)
e)
f)
Eligibility
and
Conformity
to
12.3
For the purposes of the commentary to be furnished, the Bidder shall note that
standards for workmanship, material and equipment, and references to brand
names or catalogue numbers designated by the purchaser in its technical
specifications are intended to be descriptive only and not restrictive. The
Tenderer/Bidder may substitute alternative standards, brand names and/or
catalogue numbers in its Tender/Bid, provided that it demonstrates to the
purchaser’s satisfaction that the substitutions are substantially equivalent or
superior to those designated in the technical specifications.
13
Bid Security/Earnest Money Deposit:
13.1
The Tenderer/Bidder shall furnish, as part of its Tender/Bid security
Item-wise for the amount mentioned at page no 41 for the respective item(s)
as Earnest Money Deposit (separate EMD for each item(s)).
-7-
13.2
The bid security is required to protect the purchaser against the risk of bidder’s
conduct, which may warrant the security’s forfeiture.
13.3
The bid security shall be denominated in Indian National Rupees and shall be
in the form of a Demand Draft only payable in the name of “Principal,
University College of Medical Sciences” payable at Delhi. Separate Demand
Drafts are to be submitted for each item(s).
13.4
Any Tender/Bid not secured with EMD will be rejected by the purchaser as
non-responsive. No tender shall be opened, if detail of EMD is not recorded
on top/cover of technical bid.
13.5
Unsuccessful tenderer/bidder’s tender/bid security will be discharged/returned
as promptly as possible without any interest.
13.6
The successful tenderer/bidder’s EMD will be returned (without any interest)
upon the Tenderer/Bidder’s supply of goods and furnishing the performance
bank guarantee.
13.7
The EMD may be forfeited:
a)
If a tenderer/bidder withdraws its bid during the period of tender/bid
validity specified by the tender/bidder on the tender/bid form; or
b)
In the case of successful tenderer/bidder, if the tendrer/bidder fails:
i.)
to supply the goods.
ii.)
to furnish performance bank guarantee.
c)
In case it is found at any stage that information/particulars regarding
tendered item(s) is false.
14
Period of validity of Tenders/Bids:
14.1
Tender/Bids must be valid for 150 days after the date of opening of Price bid,
prescribed by the purchaser. A tender/bid valid for a shorter period may be
rejected by the purchaser as non-responsive.
14.2
In exceptional circumstances, the purchaser may solicit the tenderer/bidder’s
consent to an extension of the period of validity. The request and the responses
thereto shall be made in writing. The tender/bid security provided shall also be
suitably extended. A tenderer/bidder may refuse the request without forfeiting
its tender/bid security.
15
Format and Signing of Tender/Bid:
15.1
The Bid shall be typed or written in indelible ink and shall be signed by the
Bidder or a person or persons duly authorized to bid the contract. The latter
authorization shall be indicated by written power of attorney accompanying
-8-
the bid. All pages of the Bid, except for unamended printed literature, shall be
initialled by the person or persons signing the tender/bid.
15.2
Any interlineations, erasure or overwriting shall be valid only if they are
initialled by the person or persons signing the tender/bid.
D. Submission of Tenders/Bids
16
Sealing and Marking of Tenders/Bids:
16.1
Tenders shall be prepared and submitted in separate sealed envelopes
(Technical and Price Bid) by superscribing all tender details and both must be
contained in a separate envelope superscribed as Tender Group _______,
Tender No ________ dated __________, DUE FOR OPENING ON
____________ FOR SUPPLY OF ________________ (name of equipment).
16.2
ALL TENDER DOCUMENT NON ADHERENCE to this may be liable for
rejection the tender/bid. The full name of contact person, mobile no., postal
address, telegraphic address and Fax/telephone no. of the tenderer shall be
written at the bottom left corner of all sealed envelops.
16.3
The Tenders/Bids prepared shall be submitted item-wise in two sealed
envelopes in two parts as follows: -
Part I.
Technical Bid
Containing priced tender/bid consisting of complete technical package of the
concerned equipment only and unpriced commercial package including tender/bid
form duly filled and signed. THE SEPARATE DEMAND DRAFT OF EARNEST
MONEY DEPOSIT MUST BE ENCLOSED IN THIS ENVELOPE. The tender
fee of Rs.2000/- (Rs two thousand only) must be enclosed with this bid by a separate
demand draft in the favour of “Principal, University College of Medical Sciences”
Payable at Delhi. No price details to be given in this tender/bid.
Blank Price schedule format (Column 1-4 only filled in) as submitted in
Section - VII (1) shall also be enclosed.
Part II.
Price Bid
Containing prices with detailed break up as per format enclosed, both in
figures and in words. Authenticated copy of Manufacturers Rate list / prices be
enclosed for justification of prices quoted to the College.
Item wise Technical Bid & Price Bid is to be submitted in separate envelopes.
Enclose separate EMD with Technical Bid for each item separately.
-9-
17
Deadline for submission of Tenders/Bids
17.1
Tenders/Bids must be received by the purchaser at the address specified not
later than the time and date specified in the invitation for tender/bid (section I
or Notice Inviting Tender). In the event of the specified date for the
submission of Tenders/Bids being declared a holiday for the Purchaser, the
Tenders/Bids will be received up to the appointed time on the next working
day.
17.2
The purchaser may, at its discretion, extend this deadline for the submission of
bids, in which case all rights and obligations of the purchaser and bidders
previously subject to the deadline will thereafter be subject to the deadline as
extended.
18
Late Tenders/Bids:
18.1
Any tender/bid received by the purchaser after the deadline for submission of
bids prescribed by the purchaser will be rejected.
19
Modification and Withdrawal of Tenders/Bids
19.1
The Tenderer/Bidder may modify or withdraw its Bid after the Bid’s
submission, provided that written notice of the modification or withdrawal is
received by the purchaser prior to the date & time prescribed for submission of
tenders/bids.
19.2
The tenderer/bidder’s modification or withdrawal notice shall be prepared,
sealed, marked and dispatched not later than the deadline for submission of
tender/bids.
19.3
No tender/bid may be modified subsequent to the deadline for submission of
bids.
19.4
No tender/bid may be withdrawn in the interval between the deadline for
submission of bids and the expiration of the period of bid validity specified by
the bidder on the bid form. Withdrawal of a bid during this interval may result
in the bidder’s forfeiture of EMD.
E. Tender/Bid Opening and Evaluation
20
Opening of Tenders/Bids by purchaser:
20.1
The purchaser will open technical bids, in the presence of tenderer/bidders
representatives who choose to attend on the date and time as indicated in NIT
(Section –I ) at the following location:
“University College of Medical Sciences, Dilshad Garden, Delhi-110095”
-10-
The tenderer/bidder “representatives who are present shall sign a register
evidencing their attendance. In the event of the specified date of Bid opening
being declared a holiday for the Purchaser, the Bids shall be opened at the
appointed time and location on the next working day.
20.2
The tenderer/bidders name, tender/bid withdrawals and the presence or
absence of the requisite bid security and such other details as the purchaser, at
its discretion, may consider appropriate will be announced at the opening.
20.3
Due to any modification(s) by the tenderer in the Tender/Bid at the time of
opening the technical bid, shall not be considered or opened for further
process, irrespective of the circumstances.
20.4
The Price Bid shall be opened only for the firm(s) whose Technical Bid is
declared qualified/acceptable by the concerned Deptt. of the purchaser .
21
Clarification of Tender/Bids:
21.1
During the examination of tenders/bids, the Purchaser may, at its discretion,
ask the tenderer/bidder for a clarification of its bid. The request can be in
writing or telephonically for clarification and the response shall be in writing
only and no change in the price or substance of the bid shall be sought, offered
or permitted.
No communication with the bidder or his representative shall be entertained
regarding the status of the procurement before completion of procurement
process.
21.2
22
Preliminary Examination:
22.1
The Purchaser will examine the tenders/bids to determine whether they are
complete, whether required sureties have been furnished, whether the
documents have been properly singed, and whether the bids are generally in
order. TENDERS/BIDS FROM AGENTS, WITHOUT PROPER
AUTHORISATION FROM THE MANUFACTURER AS PER SECTION
XII SHALL BE TREATED AS NON-RESPONSIVE.
22.2
The purchaser after opening the technical bid will examine the documents
establishing bidders eligibility and qualification, good eligibility and
conformity to bidding documents.
22.3
Deviations from or objection or reservation to critical provisions such as those
concerning Performance Scrutiny, Warranty, Force majeure, applicable law
and taxes and duties will be deemed to be a material deviation.
22.4
The Purchasers determination of the technical responsiveness is to be based on
the contents and documents of the bid itself without recourse to extrinsic
evidence.
-11-
22.5
If a tender/bid is not technically responsive, it will be rejected by the
Purchaser and may not be made responsive by the Tenderer/Bidder by the
correction of the non-conformity. No further intimation/correspondence shall
be made in this regard.
23
Evaluation and Comparison of Price Tenders/Bids:
23.1
The Tender/Bid evaluation will be done item wise.
23.2
The Purchaser’s evaluation of a price bid will take into account the following:
1.
2.
3.
4.
5.
6.
7.
Ex-factory/Ex-warehouse/Ex-showroom/Off the Shelf Price
Excise duty, if any
Packing and forwarding charges
Inland transportation, insurance and other local costs incidental to delivery.
Other incidental services, if any
Sales and other taxes payable
The costs below will also be added to the bid price for the purpose of
evaluation.
a)
Delivery Schedule:
The purchaser requires that the goods under this NIT shall be delivered within
the time specified in the schedule of requirements. A delivery “adjustment”
will be calculated for the bids at the rate of 2% of the ex-factory price
including excise duties for each month of delay beyond the stipulated delivery
period and this will be added to the bid price for evaluation. No credit will be
given to early deliveries.
24
Contacting the Purchaser:
24.1
No tenderer/bidder shall contact the purchaser on any matter relating to its bid
from the time of the bid opening to the time the contract is awarded. If the
bidder wishes to bring the additional information to the notice of the
purchaser, it should do so in writing.
24.2
Any effort by a bidder to influence the purchaser in its decisions on bid
evaluation, bid comparison or contract award may result in the rejection of the
bidder’s bid.
-12-
F. Award of Contract
25
Award Criteria:
25.1
The purchaser will award the contract to the successful Bidder who is
determined to be qualified to perform the contract satisfactorily and whose bid
has been determined to be technically responsive and has been determined as
the lowest evaluated Bid.
26
Purchaser’s Right to Vary Quantities at Time of Award:
26.1
The purchaser reserves the right at the time of award of contract to increase or
decrease the quantity of goods as per actual and services originally specified in
the schedule of requirements (rounded off to the next whole number) without
any change in price or other terms and conditions.
27
Purchaser’s Right to Accept any Bid and to Reject any or all Bids
27.1
The purchaser reserves the right to accept or reject any tender/bid (without
assigning any reason), and to annul the bidding process and reject all bids at
any time prior to award of contract, without thereby incurring any liability to
the affected bidder or bidders or any obligation to inform the affected
tenderer/bidder or bidders of the grounds for the purchaser’s action.
28
Signing / issuing the Contract:
28.1
The purchaser will issue the final purchase order / award in favour of
successful bidder and the purchase order will be treated as FINAL
CONTRACT between the Purchaser and Bidder, incorporating all necessary
terms & conditions / agreement between the parties.
28.2
If the purchase order is issued & received by the bidder, it will be presumed
that all terms & conditions given in the tender document are acceptable by the
bidder.
29
Performance Bank Guarantee :
29.1
Before the payment, the successful bidder shall furnish the Performance Bank
Guarantee in accordance with the conditions of contract, in the performance
security form provided in the bidding documents or another form acceptable to
the purchaser. The validity of Performance Bank Guarantee must be for
complete warranty period from the date of satisfactory installation.
29.2
Failure of the successful tenderer/bidder to comply with all necessary
requirements shall constitute sufficient grounds for the annulment of the award
and forfeiture of the tender/bid security in which event the purchaser may
make the award to the next lowest evaluated bidder or call for new tender/bids.
-13-
30
Corrupt or Fraudulent Practices
The College requires that tenderer/bidders/Suppliers/Contractors under
contracts, observe the highest standard of ethics during the procurement and execution
of such contracts. In pursuance of this policy, the College:
(a) Defines, for the purposes of this provision, the terms set forth as follows:
(i)
“corrupt practice” means the offering, giving, receiving or soliciting of any
thing of value to influence the action of a public official in the procurement
process or in contract execution, and
(ii)
“fraudulent practice” means a misrepresentation of facts in order to influence a
procurement process or the execution of a contract to the detriment of the
Borrower, and includes collusive practice among Bidders (prior to or after bid
submission) designed to establish bid prices at artificial non-competitive levels
and to deprive the College of the benefits of free and open competition,
a) Will reject a proposal for award if it determines that the Bidder recommended for
award has engaged in corrupt or fraudulent practices in competing for the contract
in question,
b) Will declare a firm ineligible, either indefinitely or for a stated period of time, if it
at any time determines that the firm has engaged in corrupt or fraudulent practices
in competing for, or in executing a contract.
c) If at any stage, any bidder or his supplier firm/Principal/partner etc. found BlackListed/debarred/any kind of concealment/imposed of any kind of penalty, the
College have the right to cancel the procurement even after issuing the purchase
order.
d) No bidder or their representative shall meet with any of our faculty
member/official without any prior permission of competent authority of the
College.
-14-
Section III.
General Conditions of Contract
TABLE OF CLAUSES
Clause Number
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
Topic
Definition
Application
Standards
Use of Contract Document and Information
Patent rights
Performance Bank Guarantee
Inspection and Tests
Packing
Delivery and Documents
Insurance
Transportation
Incidental Services
Spare Parts
Warranty
Payment
Prices
Change Orders
Contract Amendments
Assignments
Subcontracts
Delays in Supplier’s Performance
Liquidated Damages
Termination for Default
Force Majeure
Termination for Insolvency
Termination for Convenience
Resolution of Disputes
Governing Language
Applicable Law
Notices
Taxes and Duties
-15-
Section III. (Contd.)
General Conditions of Contract
: Details
1. Definition:
1.1
In this contract, the following terms shall be interpreted as indicated:
a)
“The contract” means the Purchase order or agreement entered between
the purchaser and the supplier, as recorded in the contract from signed by
the parties, including all attachments and appendices thereto and all
documents incorporated by reference therein;
b)
“The contract price” means the price payable to the supplier under the
contract for the full and proper performance of its contractual obligations;
c)
“The goods” means all the equipment, machinery, and/or other materials,
which the supplier is required to supply to the purchaser under the
contract.
d)
“Services” means services ancillary to the supply of the goods, such as
transportation and insurance, and any other incidental services, such as
installation, commissioning, provision of technical assistance, training and
other such obligations of the supplier covered under the contract;
e)
“GCC” means the General Conditions of Contract contained in this
section.
f)
The “purchaser” or “buyer” means the University College of Medical
Sciences.
g)
“The supplier” means the individual or firm supplying the goods &
services under this contract.
h)
“Day” means calendar day.
2. Application:
2.1
These General conditions shall apply to the extent that they are not superseded
by provisions in other parts of the contract.
3. Standards:
3.1
The goods supplied under this contract shall conform to the standards
mentioned in the technical specifications, and, when no applicable standard is
mentioned, to the authoritative standard appropriate to the goods country of
origin and such standards shall be the latest issued by the concerned
institution.
-16-
4. Use of Contract Documents and Information:
4.1
The supplier shall not, without the purchaser’s prior written consent, disclose
the contract, or any provision thereof or any specification, plan, drawing,
pattern, sample or information furnished by or on behalf of the purchaser in
connection therewith, to any person other than a person employed by the
supplier in the performance of the contract. Disclosure to any such employed
person shall be made in confidence and shall extend only so far as may be
necessary for purposes of such performance.
4.2
The supplier shall not, without the purchaser’s prior written consent, make use
of any document or information except for purposes of performing the
contract.
4.3
Any document, other than the contract itself, shall remain the property of the
purchaser and shall be returned (in all copies) to the purchaser on completion
of the supplier’s performance under the contract if so required by the
purchaser.
5. Patent Rights:
5.1
The supplier shall indemnify the purchaser against all third party claims of
infringement of patent, trademark or industrial design rights arising from use
of the goods or any part thereof in India.
6. Performance Bank Guarantee:
6.1
Before the payment, the successful bidder shall furnish the Performance Bank
Guarantee to the Purchaser for an amount of 10% of the contract value, valid
upto 60 days after the date of completion of performance obligations including
warranty obligations. The validity of Performance Bank Guarantee must be
commenced on or after the date of satisfactory installation.
In the event of any correction of defects or replacement of defective
material during the warranty period, the warranty for the corrected/replaced
material shall be extended to a further period of 24 months and the
Performance Bank Guarantee for proportionate value shall be extended 60
days over and above the extended warranty period.
6.2
The proceeds of the Performance Bank Guarantee shall be payable to the
purchaser as compensation for any loss resulting from the supplier’s failure to
complete its obligations under the contract.
6.3
The Performance Bank Guarantee shall be denominated in Indian National
Rupees, issued by a Nationalised/Scheduled bank located in India which shall
be in form of Bank Guarantee on Rs. 100/- Non-judicial stamp paper.
-17-
6.4
The Performance Bank Guarantee will be discharged by the purchaser and
returned to the supplier after the date of completion of the supplier’s
performance obligations/warranty period, including CAMC obligations under
the contract. In this regard, the concerned supplier has to take initiative by
writing a request letter to the Purchaser.
7. Inspection and Tests:
7.1
Inspection and tests prior to shipment of Goods and at final acceptance are as
follows:
i.)
The inspection of the Goods may be carried out to check whether the Goods
are in conformity with the technical specification attached to the contract and shall be
in line with the inspection/test procedures laid down in the Technical Specifications
and the General Conditions of Contract. Following broad test procedure will generally
be followed for inspection and testing of machine. The supplier will dispatch the
goods to the ultimate consignee after internal inspection testing alongwith the
supplier’s inspection report and manufacturer’s warranty certificate. The purchaser
may test the equipment after completion of the installation and commissioning at the
site of the installation. For site preparation, the supplier should furnish all details to
the purchaser sufficiently in advance so as to get the works completed before receipt
of the equipment. Complete hardware and software as specified in section V should
be supplied, installed and commissioned properly by the supplier prior to
commencement of performance tests.
ii.)
The acceptance test will be conducted by the purchaser, their consultant or any
other person nominated by the purchaser, at its option. The acceptance will involve
trouble-free operation for seven consecutive days. There shall not be any additional
charges for carrying out acceptance tests. No malfunction, partial or complete failure
of any part of hardware or excessive heating of motors etc. of all tender items or bugs
in the software should occur. All the software should be completed and no missing
modules/sections will be allowed. The supplier shall maintain necessary log in respect
of the results of the tests to establish to the entire satisfaction of the purchaser, the
successful completion of the test specified. An average uptake efficiency of 98% (to
modify as considered appropriate for each case) for the duration of test period shall be
considered as satisfactory.
iii.)
In the event of the hardware and software failing to pass the acceptance test, a
period not exceeding two weeks will be given to rectify the defects and clear the
acceptance test, failing which the purchaser reserves the rights to get the equipment
replaced by the supplier at no extra cost to the purchaser.
iv.)
Successful conduct and conclusion of the acceptance tests for the installed
goods and equipment shall also be the sole responsibility and at the cost of the
supplier.
The purchaser or its representative shall have right to inspect and/or to test the
goods to confirm their conformity to the contract. The technical specifications shall
specify what inspection and tests the purchaser requires and where they are to be
-18-
conducted. The purchaser shall notify the supplier in writing of the identity of any
representatives retained for these purposes.
7.2
The inspections and tests may be conducted on the premises of the supplier or
its subcontractor(s) at point of delivery and/or at the goods final destination.
Where conducted on the premises of the suppler or its sub-contractor(s), all
reasonable facilities and assistance including access to drawings and
production data shall be furnished to the inspectors at no charge to the
purchaser.
7.3
Should any inspected or tested goods fail to conform to the specification, the
purchaser may reject them and the supplier shall either replace the rejected
goods or make all alterations necessary to meet specification requirements free
of cost to the purchaser.
7.4
The purchaser’s right to inspect, test and, where necessary, reject the goods
after the goods arrival in the purchaser’s country shall in no way be limited or
waived by reason of the goods having previously been inspected, tested and
passed by the purchaser or its representative prior to the goods shipment from
the country of origin.
7.5
Nothing shall in any way release the supplier from any warranty or other
obligations under this contract.
Manuals and Drawings
7.6.1 Before the goods and equipments are taken over by the Purchaser, the Supplier
shall supply operation and maintenance manuals together with drawings of the
goods and equipment. These shall be in such detail as will enable the
Purchaser to operate, maintain, adjust and repair all parts of the equipment as
stated in the specifications.
7.6.2 The manuals and drawings shall be in the ruling language (English) and in
such form and numbers as stated in the contract.
7.6.3 Unless and otherwise agreed, the goods and equipment shall not be considered
to be completed for the purpose of taking over until such manuals and drawing
have been supplied to the Purchaser.
7.7
For the System & Other Software the following will apply:
The supplier shall provide complete and legal documentation of hardware, all
sub-systems, operating systems, system software and the other software. The supplier
shall also provide licensed software for all software products, whether developed by it
or acquired from others. The supplier shall also indemnify the purchaser against any
levies/penalties on account of any default in this regard.
-19-
7.8
Acceptance Certificates:
7.8.1 On successful completion of acceptability test, receipt of deliverables etc, and
after the purchaser is satisfied with the working of the system, the acceptance
certificate signed by the supplier and the representative of the purchaser will
be issued. The date on which such certificate is signed shall be deemed to be
the date of successful commissioning of the systems.
8. Packing
8.1
The supplier shall provide such packing of the goods as is required to prevent
their damage or deterioration during transit to their final destination as
indicted in the contract. The packing shall be sufficient to withstand, without
limitation, rough handling during transit and exposure to extreme
temperatures, etc. during transit and open storage. Packing case size and
weights shall take into consideration, where appropriate, the remittance of the
goods final destination and the absence of heavy handling facilities at all
points in transit.
8.2
The packing, marking and documentation within and outside the packages
shall be comply strictly with such special requirements as shall be provided for
in the contract including additional requirements, in any subsequent
instructions ordered by the purchaser.
8.3
Packing Instructions:
The supplier will be required to make separate packages for each consignee.
Each package will be marked on three sides with proper paint / indelible ink, the
following:
i.
ii.
iii.
iv.
Tender No.
Contract No.
Supplier’s Name, and
Packing list reference number
9. Delivery and documents:
9.1
Delivery of the goods shall be made by the supplier in accordance with the
terms specified by the purchaser in the notification of the Award / purchase
order. The details of shipping and/or other documents to be furnished by the
supplier are as below: -
9.2
Atleast 7 days before the delivery of the item, the supplier shall inform / notify
in writing to the purchaser on Fax No.011-22582105 with full details of the
shipment including contract person/number, Air Waybill/House Air Waybill,
railway/air receipt number and date, description of goods, quantity, name of
the consignee etc. The supplier shall also mail necessary documents to the
purchaser’s e-mail i.e. ucmscentralstore@gmail.com. If the supplier does not
intimate to the purchaser in writing about the detail of despatching the item(s),
-20-
the demurrage/any penalty or any other charges may be imposed on the
supplier.
10. Insurance:
10.1
For delivery of goods at site, the insurance shall be obtained by the Supplier in
an amount equal to 110% of the value of the goods from “warehouse to
purchaser’s place (final destinations) “on All Risks” basis including War Risks
and Strikes.
11. Transportation:
11.1
Where the supplier is required under the contract to transport the goods to a
specified place of destination within India defined as project site, transport to
such place of destination in India including insurance, as shall be specified in
the contract, shall be arranged by the supplier, and the related cost shall be
included in the contract price.
12. Incidental services:
12.1
The following services shall be furnished and the cost shall be included in the
contract price:
a)
b)
c)
Performance of the on-site assembly, commissioning and start-up of
the equipment.
Furnishing the detailed operation and maintenance manuals for each
item of supply at each location.
Maintenance and repair of the equipment at each location during the
warranty period including supply of all spares. This shall not relieve
the supplier of any warranty obligations under this contract.
13. Spare parts:
13.1
Supplier shall carry sufficient inventories to assure ex-stock supply of
consumable and spare in India. Supplier shall ensure the availability of after
sales service for a period of at least five years including the warranty period.
14. Onsite Comprehensive Warranty:
14.1
The supplier warrants that the goods supplied under this contract are new,
unused, of the most recent or current models and they incorporate all recent
improvements in design and materials unless provided otherwise in the
contract.
14.2
This comprehensive warranty (onsite) shall remain valid for 60 months (5
years) from the date of satisfactory installation of item.
14.3
The purchaser shall promptly notify the supplier in writing of any claims
arising under this warranty.
-21-
14.4
“Upon receipt of such notice, the Supplier, within 24 hours repairs or replace
the defective goods or parts thereof, free of cost at the ultimate destination.
The supplier shall take over the replaced parts/goods at the time of their
replacement. No claim whatsoever shall lie on the Purchaser for the replaced
parts/goods thereafter.
14.5
If the supplier, having been notified, fails to remedy the defect(s) within 24
hours, the Purchaser may proceed to take such remedial action as may be
necessary, at the Supplier’s risk and expense without prejudice to any other
rights which the Purchaser may have against the Supplier under the Contract.
14.6
The supplier shall guarantee a 98% uptime of computer systems/peripherals &
all tender items or other equipment’s being supplied.
14.7
If any computer systems/tender items give continuous trouble, say three times
in one month during the warranty period, the supplier must replace the system
with new system without any additional cost to the purchaser.
14.8
Maintenance service
i. Free maintenance services shall be provided by the supplier during the period
of warranty.
ii. It is expected that the average downtime of the item (system) will be less than
half the maximum downtime (i.e. defined as number of days for which an item
of equipment is not usable because of inability of the supplier to repair it) as
mentioned in the form of technical details. In case an item is not usable
beyond the stipulated maximum downtime the supplier will be required to
arrange for an immediate replacement of the same till it is repaired. Failure to
arrange for the immediate repair/replacement will be liable for a penalty of
Rs.100 per day per item. The amount of penalty will be recovered from the
Performance Bank Guarantee during warranty period.
15. Payment
Payment for Goods and Services shall be made either through Letter of Credit
(80%/20%)/FDD or in Indian National Rupees after submission of valid Performance
Bank guarantee as well as after satisfactory installation.
16. Prices
16.1
Prices payable to the supplier as stated in the contract shall be fixed.
17. Change Orders
17.1
The purchaser may at any time, by a written order given to the supplier, make
changes within the general scope of the contract in any one or more of the
following:
-22-
a) Drawings, designs or specifications where Goods to be furnished under the
Contract are to be specifically manufactured for the Purchaser;
b) The method of shipment or packing;
c) The place of delivery; or
d) The services to be provided by Supplier.
17.2
If any such change causes an increase or decrease in the cost of, or the time
required for, the supplier’s performance of any part of the work under the
Contract, whether changed or not changed by the order, an equitable
adjustment shall be made in the contract Price or delivery schedule, or both,
and the Contract shall accordingly be amended. Any claims by the supplier for
adjustment under this clause must be assorted within thirty (30) days from the
date of the Supplier’s receipt of the Purchaser’s change order.
18. Contract Amendments
18.1
No variation in or modification of the terms of the Contract shall be made
except by written amendment signed by the parties.
19. Assignment
19.1
The supplier shall not assign, in whole or in part, its obligations to perform
under the Contract, except with the Purchaser’s prior written consent.
20. Sub-contract
20.1
The supplier shall notify the Purchaser in writing of all subcontracts in his
original bid otherwise the supplier shall not relieve from any liability or
obligation under the Contract.
21. Delays in the Supplier’s Performance
21.1
Delivery of the Goods and performance of Services shall be made by the
Supplier in accordance with the time schedule specified by the Purchaser in
the Schedule of Requirements.
21.2
If at any time during performance of the Contract, the Supplier or its
subcontractor(s) should encounter conditions impeding timely delivery of the
Goods and performance of Services, the Supplier shall promptly notify the
Purchaser in writing of the fact of the delay, its likely duration and its cause(s).
As soon as practicable after receipt of the supplier’s notice, the Purchaser shall
evaluate the situation and may at its discretion extend the Supplier’s time for
performance, with or without liquidated damages, in which case the extension
shall be ratified by the parties by amendment of the Contract.
21.3
Except as provided in GCC clause 24, a delay by the Supplier in the
performance of its delivery obligations shall render the Supplier liable to the
imposition of liquidated damages unless an extension of the time is agreed
upon without application of liquidated damages.
-23-
22. Liquidated Damages
22.1
If the Supplier fails to deliver any or all of the Goods or to perform the
Services within the period(s) specified in the Contract, the Purchaser shall,
without prejudice to its other remedies under the Contract, deduct from the
Contract price, as liquidated damages, a sum equivalent to 0.5% of the delayed
goods or unperformed services for each week or part thereof of delay until
actual delivery or performance, up to a maximum deduction of 10 percent of
contract price. Once the maximum is reached, the Purchaser may consider
termination of the Contract.
23. Termination for Default
23.1
The Purchaser may, without prejudice to any other remedy for breach of
contract, by written notice of default sent to the supplier, terminate the
contract in whole or in part;
a) If the supplier fails to deliver any or all of the Goods within the period(s) specified
in the Contract, or within any extension thereof granted by the Purchaser.
b) If the supplier fails to perform any other obligation(s) under the contract.
c) If the supplier, in the judgment of the purchaser has engaged in corrupt or
fraudulent practices in competing for or in executing the contract.
For the purpose of this clause:
“Corrupt practice” means the offering. Giving, receiving or soliciting of any thing of
value to influence the action of a public official in the procurement process or in
contract execution.
“Fraudulent practice’ means a misrepresentation of facts in order to influence a
procurement process or the execution of a contract to the detriment of the University
College of Medical Sciences, and includes collusive practice among Bidders (prior to
or after bid submission designed to establish bid prices at artificial non-competitive
levels and to deprive the University College of Medical Sciences of the benefits of
free and open competition.
23.2 In the event the Purchaser terminates the Contract in whole or in part, the
Purchaser may procure, upon such terms and in such manner as it deems
appropriate, Goods or services similar to those undelivered, and the supplier
shall be liable to the Purchaser for any excess costs for such similar Goods or
services. However, the supplier shall continue the performance of the Contract,
to the extent not terminated.
24. Force Majeure
24.1 Notwithstanding the provisions of GCC clauses 21, 22, 23, the supplier shall not
be liable for forfeiture of its performance security, liquidated damages or
termination for default, if and to the extent that, its delay in performance or
other failure to perform its obligations under the contract is the result of an event
of Force majeure.
-24-
24.2 For purposes of this clause, “Force majeure” means an event beyond the control
of the supplier and not involving the suppliers fault or negligence and not
foreseeable. Such events may include, but are not limited to, acts of the
purchaser either in its sovereign or contractual capacity, wars or revolutions,
fires, floods, epidemics, quarantine restrictions and freight embargoes.
24.3 If a force majeure situation arises, the supplier shall promptly notify the
purchaser in writing of such condition and the cause thereof. Unless otherwise
directed by purchaser in writing, the supplier shall continue to perform its
obligations under the contract as far as is reasonable practical, and shall seek all
reasonable alternative means for performance not prevented by the Force
Majeure event.
25. Termination for Insolvency:
25.1 The purchaser may at any time terminate the contract by giving written notice to
the supplier, if the supplier becomes bankrupt or otherwise insolvent. In this
event, termination will be without compensation to the supplier, provided that
such termination will not prejudice or affect any right of action or remedy,
which has accrued or will accrue thereafter to the purchaser.
26. Termination for Convenience;
26.1 The purchaser, by written notice sent to the supplier, may & terminate the
contract, in whole or in part, at any time for its convenience. The notice of
termination shall specify that termination is for the purchaser’s convenience, the
extent to which performance of work under the contract is terminated, and the
date upon which such termination becomes effective.
26.2 The goods that are complete and ready for shipment within 30 days after the
supplier’s receipt of notice of termination shall be accepted by the purchaser at
the contract terms and prices. For the remaining goods, the purchaser may elect;
a) to have any portion completed and delivered at the contract terms and prices;
and/or
b) to cancel the remainder and pay to the supplier an agreed amount for partially
completed goods and for materials and parts previously procured by the supplier.
27. Resolution of Disputes:
27.1 The purchaser and the supplier shall make every effort to resolve amicably by
direct informal negotiation any disagreement or dispute arising between them
under or in connection with the contract.
-25-
28. Governing Language:
28.1 The contract shall be written in the English language.
29. Applicable law:
29.1 The contract shall be interpreted in accordance with the laws of the Union of
India.
30. Notices:
30.1 Any notice given by one party to the other pursuant to this contract shall be sent
to other party in writing and confirmed in writing to the address specified in the
tender notice.
30.2 A notice shall be effective when delivered or on the notices effective date,
whichever is later.
31. Taxes and Duties:
31.1 The supplier shall be entirely responsible for all taxes, duties, license fees, octroi,
road permits etc. incurred until delivery of the contracted goods to the
purchaser. Supplier is also requested to submit the copy of registration
certificate of Sale Tax or DVAT or any other taxes, whichever is applicable.
-26-
Section –IV
Complete Technical Specification of All Tender Items
S. No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Tender Group
Anatomy
Physiology
Community Medicine
MRU
Patho – Histo
Patho–Hemato
Pathology – TT
Patho– Cyto
Biochemistry
Forensic Medicine
MIU
Micro
-27-
Page No.
43
43-45
45
45-55
55-59
59
60
61
61-63
64-65
65
65-72
SECTION –V
Scheduled of Requirement
For all tenders items the delivery period will be 4 to 6 weeks or as indicated in the
final contract or purchase order.
SECTION – VI
QUALIFICATION REQUIREMENTS
1. The bidder should be a manufacturer/authorized representative of a
manufacturer who must have designed, manufactured, tested and supplied the
equipment(s) similar to the type specified in the “schedule of requirements”
upto at least 50% of the quantity required in any one of the last 3 years. Such
equipments must be of the most recent series models incorporating the latest
improvements in design. The models should be in successful operation for
about six months as on date of bid opening.
2. The bidder should furnish the information on all past supplies and satisfactory
performance in proforma attached.
3. All bids submitted shall also include the following information.
i)
Copies of original documents defining the constitution or legal
status, place or registration and principle place of business of at the
company or firm or partnership, etc.
ii)
The bidder should furnish a brief write up, backed with adequate
data, explaining his available capacity and experience (both
technical and commercial) for the manufacture and supply of the
required systems and equipment within the specified time of
completion after meeting all their current commitments.
iii)
The bidder should clearly confirm that all the facilities exist in his
factory for inspection and testing and these will be made available
to the Purchase or his representative for inspection.
iv)
Details of Service Centers and information on service support
facilities that would be provided during the warranty period (in
Service Support form).
v)
Reports on financial standing of the Bidder such as profit and loss
statements, balance sheets and auditor’s report of the past three
years, bankers certificates, etc.
-28-
SECTION - VII
1. PRICE SCHEDULE
Sl.
No.
[1]
Description of item
Tender
Deviations with
Specification
respect to
Tender
specifications
[2]
[3]
Country of
origin
[4]
Quantity
and unit
(5)
Ex-factory /Ex –
warehouse/Exshowroom/Off
the self
(a)
(6)
Excise
duty if
any
Packing &
forwarding
(c)
(b)
(7)
(8)
UNIT PRICE
Inland Transportation,
Incidental
Insurance and other
Services
local costs incidental to
delivery
(d)
(e)
(9)
Sale Tax & other
taxes payable if
contract
is
awarded
(f)
Any Other
Charges
(if applicable)
(11)
(12)
(10)
Unit Price
Grand Total
on DDP/FOR basis
A+b+c+d+e+f+g
(Col.5x13)
(g)
(13)
(14)
IF RATES ARE QUOTED IN INDIAN NATIONAL RUPEES (INR), THE RATES MUST BE ON FOR (DESTINATION OF PURCHASER) BASIS.
IF RATES ARE QUOTED IN FOREIGN CURRENCY, THE RATES MUST BE ON DDP (DELIVERED DUTY PAID) BASIS INCLUDING INSURANCE OF THE ITEM, PLEASE REFER POINT NO.9
Note: i) In case of discrepancy between unit price and total prices, THE UNIT PRICE shall prevail.
Total Bid Price in Rupees(Grand Total)……………………………
In words…………………………………………………………….
Bidder’s Signature…………………………………..
Name …………………………………………………..
Business Address………………………………………
Place:
Date:
-29-
Section VII (Contd.)
2. TIME SCHEDULE
Name of The Bidder ___________________________________
Item
Sl. No.
[1]
Description of Item
Country
of
Origin
Tender
Specification
Deviations with
respect to
Tender
specifications
[2A]
[2B]
Unit
[3
[4]
-30-
Quantity
Destination
(consignees)
Delivery
period
require
[5]
[6]
[7]
SECTION –VIII
1. TENDER/BID FORM
Date…………….
Tender No…………..
Tender Group …………..
To
(Name and address of purchaser)
Gentlemen and /or Ladies:
Having examined the Bidding Documents vide Tender No. ………………., we, the
undersigned, offer to supply and deliver…………… (Description of Goods and
Services) in conformity with the said bidding documents.
We undertake, if our bid is accepted, to deliver the goods in accordance with the
delivery schedule specified in the final award/contract.
If our bid is accepted, we will obtain the guarantee of a bank in a sum equivalent to
10 percent of the Contract Price for the due performance of the Contract, in the form
prescribed by the Purchaser.
We agree to abide by this bid for a period of 150 days after the date fixed from bid
opening and it shall remain binding upon us and may be accepted at any time before
the expiration of that period.
We undertake that, in competing for (and, if the award is made to us, in executing) the
above contract, we will strictly observe the laws against fraud and corruption in force
in India namely “Prevention of Corruption Act 1988”.
We understand that you are not bound to accept the lowest or any bid you may
receive.
Dated this …… day of ………... 2015
…………………………………..
(Signature)
……………………
(In the capacity of )
Duly authorized to sign Bid for and on behalf of
…………………………………………………………………………………………..
-31-
Section VIII. (Contd..)
2. BID SECURITY or EARNEST MONEY DEPOSIT
The bid security shall be denominated in Indian National Rupees and shall be in the
form of a Demand Draft only payable in the name of “Principal, University College of
Medical Sciences” payable at Delhi. Separate Demand Drafts are to be submitted
for each item(s).
The Tenderer/Bidder shall furnish EMD(s)/Bid security Item-wise for the amount
mentioned at page no 41-42 for the respective item(s).
-32-
SECTION – IX
FINAL CONTRACT
The purchaser will issue the final purchase order / award in favour of successful
bidder and the purchase order will be treated as FINAL CONTRACT between the
Purchaser and Bidder, incorporating all necessary terms & conditions / agreement
between the parties.
-33-
Section X
PERFORMANCE BANK GUARANTEE
To:
(Name of Purchaser)
WHEREAS
(Name of supplier)
Hereinafter called “the Supplier” has undertaken, in pursuance of Purchase Order No.
………….. dated ……………… 201…. To supply (Description of Goods and
Services) hereinafter called “the Contract”, costing Rs………………………… (value
of Purchase Order)
AND WHEREAS it has been stipulated by you in the said Contract that the Supplier
shall furnish you with a Bank Guarantee by a recognised bank for the sum specified
therein as security for compliance with the Supplier’s performance obligations in
accordance with the Contract.
AND WHEREAS we have agreed to give the Supplier a Guarantee:
THEREFORE WE hereby affirm that we are Guarantors and responsible to you, on
behalf of the Supplier, up to a total of (*Amount of the Guarantee in Words and
Figures) and we undertake to pay you, upon your first written demand declaring the
Supplier to be in default under the Contract and without cavil or argument, any sum or
sums within the limits of (Amount of Guarantee) as aforesaid, without your needing
to prove or to show grounds or reasons for your demand or the sum specified therein.
This guarantee is valid until the ……… day of ……… 201…
Signature and Seal of the Guarantors
Date…………….
Address ………………..
-34-
SECTION XI
Proforma for Performance Statement
Bid No. ………………………
Date of opening : …………………………
Time : ………. Hrs. ………………
Name of the Firm ………………………………………………………………………………………………………………………….
Order placed by
(full address of &
date purchaser)
Order No. &
date
Description &
quantity or of
ordered equipment
Value or
order
Date of
completion of
delivery As per
Actual Contract
Remarks
indicating
reasons for late
delivery
Has the equipment been
satisfactorily functioning
(Attach a certificate from
Purchaser / Consignee)
Signature and Seal of the Bidder ………………………………………
……………………………………
-35-
SECTION – XII
MANUFACTURERS’ AUTHORIZATION FORM
No…………..Dated: ………………….
To,
The Principal,
University College of Medical Sciences,
Dilshad Garden, Delhi-110095
Dear Sir,
Tender No…………………
We ……………. Who are established and reputable manufacturers of ……………….
(name
&
descriptions
of
goods
offered)
having
factories
at
……………….…………………………. (address of factory) do hereby authorize
M/s. …………….( Name and address of authorised dealer) to submit a bid, and sign
the contract with you against the above NIT.
We hereby extend our comprehensive onsite guarantee and warranty for a period of 5
(Five) years from the date of satisfactory installation for the goods and services
offered by the above firm against this Bid.
Yours faithfully
(Name)
(Name of Manufacturers)
Note: this letter of authority should be on the letterhead of the manufacturer and
should be signed by a person competent and having the power of attorney to bind the
manufacturer. It should be included by the Bidder in its Bid.
-36-
SECTION –XIII
CAPABILITY STATEMENT
1. Name and address of the bidder ………………………….Phone:
2. Classifications
1) Manufacturer
(Circle what is applicable) 2) Authorised Agent
3) Dealer
4) Others please specify
3. Plant:
a) Location
b) Description, Type and size of building
c) Is property on lease or free hold? If on lease indicate date of expiry of lease in
each case.
4.
a) Type of equipment manufactured and supplied during last 2 years
Name of
Equipment
Capacity/
Size
Nos.
Manufactured
Projects to which
supplies are made
No. of orders
on hand
b) Type of equipment manufactured, supplied, installed and commissioned
during last 2 years
Name of
Equipment
Capacity/
Size
Nos.
Manufactured
Projects to which
supplied installed
and commissioned
No. of orders
on hand
5.
a) Types of equipment supplied during last 2 years other than those covered
under 4 above.
Name of
Equipment
Capacity/
Size and
Model
Nos.
Manufacturers &
country of
Origin
Total
Nos.
supplied
in India
Projects to
which
supplies are
made
No. of
orders in
hand
b) Type of equipment supplied, installed and commissioned during last 2 years
other than those covered under 4(a) and (b) above.
Name of
Equipment
Capacity/
Size and
Model
Nos.
Total
Manufacturers &
Nos.
country of
supplied
Origin
in India
-37-
Projects to
which
supplies are
made
No. of
orders in
hand
6. Plant facilities:
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
Sq. Meter (Remarks)
Space available for manufacture
Space available for storage
Space available for inspection items offered
Space available for storage items offered
Are buildings fire resistant
Are premises approved by Municipal
Yes/ No
fire
Production?
Are buildings under municipal fire Production?
Are power and fuel supply adequate to meet production requirements?
Are adequate transportation facilities available?
Are safety measures adequate for performance of proposed contract?
Are adequate material handling available
7. Details of Testing facilities available
a) List testing equipment available
b) Give details of tests which can be carried out on items offered
c) Details of the testing organization available.
8. Personnel/ Organization:
1.
2.
3.
4.
5.
6.
Production
Marketing
Installation and Commissioning
Service
Spare parts
Administrative
9. Nearest service centre to buyer:
Location ……………………………………… Phone No. ……………………
10. Details of organization at Service Centre
a)
b)
c)
d)
e)
f)
g)
No. of skilled employees
No. of unskilled employees
No. of engineering employees
No. of administrative employees
List of special repair/workshop facility available
The storage space available for spare parts
Value of minimum stock of spares available at all the service centres in
respective currency
h) List of the models/types by number of equipment serviced by the
centre in last 2 years
-38-
11. Names of two buyers to whom similar equipment are supplied installed and
commissioned in the past and to whom reference may be made by the
purchaser regarding the bidder’s technical and delivery ability:
1. …………………
2. …………………
12. List of components usually subcontracted……………………..
13. Schedules for furnishing technical data and certified drawings after receipt of
orders……………………………………..
14. Workload as percentage of total capacity for the current and 8 forthcoming
financial year on quarterly basis…………………………………..
15. Number of weeks required to prepare a bid proposal…………………………..
HARDWARE DOWNTIME
What is the minimum downtime you will guarantee on each of the following
items. (This is defined as the number of days for which an item of equipment is
not usable because of inability of the supplier to repair it)
Item
No. of days of max down time
ALL TENDER ITEMS
Note:1. The average down time of each item should not exceed half the maximum
down time.
2. If the maximum down time during use in warranty/maintenance 8 period
exceeds the maximum down time as specified in the bid, the supplier should
arrange immediate replacement. Failure to arrange for the immediate
replacement shall render the suppler liable to a penalty as specified in the
special conditions of contract.
Signature of Bidder ……………………
Business Address……………………..
-39-
SECTION XIV
SERVICE SUPPORT DETAILS
NEAREST SERVICE CENTRE
PACK NO.
DESTINATION
LOCATION
PHONE NO.
TELEX NO.
STATUS OF
OFFICEWORKING
DAYS & HOURS
NO. OF
SOFTWARE
ENGINEERS
NO. OF
HARDWARE
STAFF
VAL. OF
MIN. STOCK
AVAILABLE
AT ALL
TIMES
LIST OF
MODELS &
TYPES OF PCs
SERVICED IN
LAST 2 YEARS
Signature and Seal of Manufacturer/Bidder
-40-
University College of Medical Sciences
Dilshad Garden Delhi-110095
List of items to be purchased through Open General Tender 2015-16
Tender Group
S.No.
Anatomy
Physiology
1.
2.
3.
4.
Community
Medicine
MRU
5.
Patho – Histo
Patho–Hemato
Pathology – TT
Patho– Cyto
Biochemistry
Forensic Medicine
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
Name of the Item
Quantity
required
(in nos)
EMD to be
enclosed with
Technical Bid
(In INR)
Embalming Machine
Perimeter
Mosso’s Erogograph
Pulmonary Function Testing machine with diffusion and body
plethysmography
Ice Lined Refrigerator (ILR)
1
10
5
1
3,000/9,000/4,000/90,000/-
Page No. of
the
specification
in Tender
Document
43
43
43
43-45
1
3,500/-
45
Liquid Nitrogen Container
Autoclave
Vacuum Pump for Media Filtration & Solid Phase Extraction (SPE)
Centrifuge Machine
Gas Chromatography – Mass Spectrometer
UV-VIS Double beam Spectrophotometer with temperature control
and data management system
Atomic Absorption spectrophotometer with fume hood
Semi – Micro Weighing Balance
Inverted Microscope with phase Contrast and CCD Camera
Refrigerated Out – swing Centrifuge
-150 0 C Deep Freezer
Slide Warming Plate
Slide Filing Cabinet
Orbital Shaker (Non-incubated)
Gross Station
Waste Tray for Manual Rotary Microtome
Block Filing Cabinet
Automated Tissue Processor with Fume Control, Bench Top
Tissue Flotation Bath
Spectrum Gold Filter for existing Upright Trinocular Research
Fluorescent Microscope with Digital Image Analysis system
Electrically operated glass etching hand held tool
Ultrapure Type I Water Purification System
Fully automated microplate ELISA Reader with printer
Projection System for 7 Headed teaching Microscope
Upright LED microscope with imaging system
PH/ORP probe with Liquid gel and polymer electrolyte
Incubator (Table Top)
Antigen Retrieval System
Semi-Autoanalyser
Micro-Centrifuge
Gradient Thermal Cycler
Height Weight Machine
Human Bone (Adult & Original)
1
1
1
1
1
2
1,000/4,500/3,000/1,500/1,50,000/90,000/-
45
45-46
46
46-47
47-50
50-51
1
1
1
1
1
1
2
1
1
2
2
1
1
1
1,10,000/8,000/20,000/10,000/40,000/450/2,500/3,000/80,000/1,000/3,000/50,000/450/6,000/-
51-53
53
53-54
54-55
55
55-56
56
56
56-57
57
57
57-58
58
58
1
1
1
1
1
1
1
1
1
1
1
1
4,000/20,000/10,000/3,500/35,000/1,500/700/9,000/6,000/20,000/20,000/400/1,00,000/-
58-59
59
59
59
60
61
61
61
61-62
62-63
63
64
64
900/1500/-
64
64-65
39. X-Ray View Box
40. Digital Weighing Balance
Pls. refer
detailed
specification
10
1
41
Tender Group
MIU
Micro
S..No.
Name of the Item
Quantity
required
(in nos.)
EMD to be
enclosed with
Technical Bid
(In INR)
41. Plotter Printer
42. Photo Printer/Photo Inkjet Printer
1
1
15,000/3,000/-
Page No. of
the
specification
in Tender
Document
65
65
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
1
1
5
21
2
2
1
2
2
2
1
1
40,000/20,000/4,000/20,000/10,000/700/3,000/3,000/4,000/4,000/15,000/1,500/-
65-67
67-68
68
68-69
69-70
70
70
70
71
71
71-72
72
Fluorescent Trinocular Microscope
Brightfeild Trinocular Microscope
Refrigerator Double Door
Binocular Microscope
B.O.D Incubator
Microwave Oven
Vertical Autoclave
VDRL Shaker Digital
Water Bath
Clinical Centrifuge Table Top
Inspissator
Egg Incubator
42
University College of Medical Sciences
Open General Tender 2015-16
Tender Group – Anatomy
S. No.
1.
Name of Item
Embalming Machine
Specification
Embalming Machine -
Fluid Tank
-
Machine meant for injecting the solution to the cadavers.
The unit should be made of Stainless steel tank of 10 litre capacity with a reciprocatory
pressure unit. Tank should have a safety valve, pressure gauge with rubber tubing for
injection.
Unit to be mounted on a portable trolley with castor wheels.
Machine to be supplied by electric cord, plug and suitable to work on 220 V, 50 Hz, AC supply.
Tender Group – Physiology
1.
Perimeter
2.
Mosso’s Erogograph
3.
Pulmonary Function
Testing machine
with diffusion and
body
plethysmography
1. Perimeter Priestly Smith table model for table top use.
2. Used to measure the peripheral field of vision.
3. The apparatus comprises of a calibrated arc & revolving chart holder.
4. The object carrier which moves over the arc, contains five colours & five apertures of different diameters.
5. There is a calibrated scale and an adjustable chin rest.
6. All fitted over a sturdy base with receptacle for keeping charts.
7. Complete set required with 100 charts.
1. Apparatus used to measure work done by forearm muscles in humans.
2. The apparatus consists of arm rest, finger holders, straps and recording unit with automatic rachet.
It should have the advantages of both the Dubois and Mosso’s Ergograph.
3. The recording system follows the Dubois design; and the arm rest, finger holders and straps follow
the Mosso’s design.
4. Complete with one set of 5 kilo weight.
1.
2.
3.
4.
5.
6.
7.
Spirometry & Flow volume parameters (FVC, FEV1, FEF25, FEF50, FEF75, PEF,PIF etc)
Slow vital capacity (ERV,IRV, IC,VT, VCI, VCEX, VCMAX)
Maximum Ventilation volume (MVV)
Graphic display of Flow/volume, Volume /time loop
Thoracic gas volumes & capacities including TGV, RV, TLC,FRC
Single breath diffusion capacity (DLCO) by Carbon Monoxide technique
Diffusion capacity of lungs: Intrabreath
43
8.
9.
10.
11.
Airway Resistance and Conductance- sReff, Reff, SRtot, Rtot etc
Maximal Inspiratory/Expiratory muscle strength
Pre & post Bronchodilator test
Body Plethysmograph:
a) Should have a wide cabin with internal volume range of 800-950 litres
b) Transparent glass walls to ensure visibility from all sides
c) Seat must be comfortable and adjustable in height
d) The arm for the breathing valve support must be flexible enough to allow tests execution even outside
the cabin
e) Controlling station should be on a movable trolley
f) Compensation box for automatic compensation of pressure changes in environment
g) Intercom for communication with the patient
h) Facility for door closing & opening both by operator and patient
12. Should have precision bidirectional Pneumotach Transducer with
Flow range: 0-20 L/s,
Accuracy: 0.2-12 L/s, ± 2%
Resistance: < 0.5 cmH2O/L/s (0.05kpa/L/s at 10 L/s)
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
Volume range: ± 20L
Accuracy: ± 3% or ± 50 ml
Resolution: 1 ml
Should have precision Pressure Transducers for box, mouth and flow
Box pressure sensor should be Piezoresistive range ± 1 cm H2O, Resolution 0.05 cm H2O
Mouth pressure sensor should also be Piezoresistive range ± 70 cm H2O, Resolution 0.1 cm H2O
It should also have Linear gas analyzers
Carbon monoxide analyzer range 0-0.33 % CO, Accuracy ± 0.003%, Resolution: 0.0005%, Response
time < 350 ms
Multi gas analyser for CO & CH4
It should have a facility for automatic BTPS corrections, Gas control module with automatic filing circuit,
Rapid and accurate calibration
Should be compatible with Windows 7/8 operating system
System should be compatible with ATS/ERS guidelines and meets all international safety standards, CE,
ISO & US FDA
Should be supplied with Mobile Trolley including isolation transformer
Should have standard accessories, precision calibration syringe, connecting cables, PFT software and
Manual.
Additional Accessories: Pulmonary filters-500, Pneumotach screens-2, nose clips-20, Pressure regulator
kit-1 set & Sample tubes-2
Computer: Latest branded Core i-7 Processor, 4 GB RAM, 18.5” LED color display monitor, DVD Writer,
Mouse, Windows-7, Deskjet color printer, 6 KA Online UPS.
Gases: Diffusion gas mixture cylinders-2
Proper demonstrations to be carried out before finalizing
Onsite training should be provided by the company experts for 7-10 days
44
27. Th system should have world wide installation, acceptance and recognition in published research papers
globally. Performance certificates should be provided from the users using the system in India?abroad.
Tender Group – Community Medicine
1.
Ice Lined
Refrigerator (ILR)
1.Temperature range : 2 to 8 degree centigrade
2.Vaccine Capacity: Around 50 Litres
3.Temperature Display: to be present
4.Holdover time: Around 12-18 hours
5. Defrost: Automatic preferable.
6.World Health Organization (WHO) / UNICEF / PQS approved
Tender Group – MRU
1.
2.
Liquid Nitrogen Container
Autoclave

System should has the total capacity of total liquid nitrogen around 20-35 Liter.

System should have the storage capacity around 650 samples or more in 2 ml vial.

System should have static holding time 87 days.

System should come with compatible canister at least 6 in number.

System should have minimum neck opening around 3.8 inch to reduce the evaporation.

System should come with low level alarm system.

System should be with vacuum insulation.

System should come with mobility arrangement.

System should have international safety standard such as UL and C-UL.

Optional accessories should be quoted by vender to make this machine operational (LN2 level
scale, Cryogloves, LN2 carry container 3-4 litre).


Quality Certification: System should have EU, CE and ISO certification.
User list with name, email and telephone number of user of the quoted model.
 Capacity 25 Liters (approx).
o
 Sterilization temperature 121/134 C
 System should be hydraulic tested up to 40 PSI , provided with heating element which are easily
replaceable.
 System should have steam lined construction, outer body made up of mild steel finished with paint,
45





3.
Vacuum Pump for Media
Filtration & Solid Phase
Extraction (SPE)
inner chamber made up of stainless steel.
System should also be fitted with pressure guage, stem released cocks, spring loaded safety valve etc.
System should be fitted water level indicator to indicate the level inside the boiler.
System should be fitted with paddle lifting device to open or to close the lid with the help of paddle
Quality Certification: System should have EU, CE and ISO certification.
User list with name, email and telephone number of user of the quoted model.
VACUUM PUMP
GENERAL SPECIFICATIONS:
 Single Stage Oil – Free Diaphragm Pump

Suitable for Pumping Corrosive Gases and Vapors

All contact parts to be made of Chemically Resistant Fluoroplastics

PTFE – Sandwich Diaphragm

Direct Drive System for Ultra – low- vibration and noise
TECHNICAL SPECIFICATION
 Number of heads / stages

Max. pumping speed at 50/60 Hz

Ultimate vacuum (abs.)

Max. back pressure (abs.)
1.1 bar

Inlet connection
Hose nozzle DN 10 mm

Outlet connection
Hose nozzle DN 10 mm

Rated motor power
0.04 kW

Approx. Dimensions (L x W x H)
247 x 121 x 145 mm

Approx. Weight
ACCESSORIES:
1-
4.
Centrifuge Machine
1/1



0.7/0.85 m³/h
100 mbar
5.0 kg
Rubber vacuum tubing DN 10 mm
2-
Chemistry vacuum regulator valve with manometer
3-
Silencer DN 10 mm
Maximum speed: up to 6500 RPM
Swing type rotor heads with various size test tubes
Stepless speed regulator with zero start interlock
46
5.
Gas Chromatography
Mass Spectrometer
–







Speed holding accuracy 100 RPM
Digital speed indicator
Dynamic brake
0-99 minutes digital countdown timer
Imbalance detector with cutoff
Safety lid interlock to prevent cover opening during centrifugation
Self-diagnosis for errors

Fully automatic computer controlled GCMS with programmable electronic control and having
capability of qualitative and quantitative analysis
Should have inbuilt GC main frame with Split / Split less Injection port GC with Pneumatic Flow
Control capability Accommodates up to two capillary columns
Operating temperature range suitable for all columns and chromatographic separation
Temperature Range: Ambient +4°C to 450°C (Programmable up to 450 °C) heat up time should be
>5 min.
Temperature Programming supports > 9 oven ramps or better
Setting : 1 deg C/min
Temperature Ramp Rate: 120 °C /min, 0.1 °C /min increments
Should Equipped with a cooling system, that enable the reduction of cool down time from 450 deg
C to 50 deg C <5 minutes
Software Pneumatic Control up to 0.01psi or better
Mass Spectrometer
Mass range 1.6 – 1050 amu in 0.1 amu steps
Scan speed >12,000 amu or better.
Ionization modes: Electronic Ionization(EI) and Positive and Negative Chemical Ionization (CI)
Ion source temp: upto 350 oC for better sensitivity for active compounds and should be
programmable transfer temp 100 oC to 350 oC.
Mass analyzer should be based on Quadrupole with high ion transmission efficiency.
Quadrupole temp: optimizable as per the system requirement.
Vacuum Compensation and automatic leak testing with MS
The detector should have provision to reduce the random noise that occurs with ion transmission,
improving the S/N ratio
Scan sensitivity Using helium as carrier gas S/N Ratio in simultaneous SIM and SCAN mode
EI full scan specs
1 µL injection of 1 pg/µL OFN at S/N ≥ 600:1
PCI full scan specs
1 µL injection of 100 pg/µL benzophenone at S/N ≥ 600:1
NCI full scan specs
2 µL injection of 100 fg/µL OFN S/N ≥ 1000:1
Columns
Capillary Column DB-5, 60 mt (or equivalent phase) (2 Nos.)
Capillary Column DB-35 Ultra inert, 60 mt (or equivalent phase) (2 Nos)






















47



























Capillary Column DB-WAX, 60 mt (or equivalent phase) (1 Nos)
Head Space Auto sampler
With transfer line/direct injection technique
With at least 10 vials capacity or more.
Entire system heating from ambient up to 200 oC or better in increments of 1oC Vial temperature
50 oC – 200 oC or better.
Overlapped Thermostatting (Vials) 1
Transfer Line temperature 50 oC – 200 oC or better
Operated through GC Software
Injection volume linearity be 99% correlation and Area Reproducibility ASDA 3%
Injectors should be either do single or simultaneous injections for both injection ports.
Includes all standard accessories like interface cable, reducing union, HSS Vials 22 ml with 20 mm
round top, Crimps Caps, Silicon Rubber/Teflon face septa, Hand Crimper, De-capper etc
Auto Injector
Sample vial Glass construction, 1.5 – 2.0mL, screw top, Teflon-coated septum. Should be
supplied with minimum 15 vials capacity with septum & caps
Priority sample injection can be injected during a sample sequence, and then the sequence can
be resumed.
Pneumatic controls
Electronic pneumatic controls should be integral part of injector and detector modules No extra
tubing and wires should be needed to operate electrical valves, and deliver carrier, detector and
make-up gases to injectors and detectors. The digital carrier gas controller should allow operating
in constant and programmed flow and pressure modes.
Injectors (Two Numbers)
Split / Split less capillary Injector
Suitable for all capillary columns (50 pm to 530pm id)
Spilt less mode for trace analysis
Temperature Range 400°C
Split Ratio Setting Up to 1:900 (1 / 1 ratio increment)
Programmable Capillary Injection Unit. Should support the analysis of compounds with a high
boiling point (straight-chain hydrocarbons with 100 carbon number)
Modes of operation : Spilt/Split less, temperature ramped Split less
OCI/PTV and Spilt/Split less capillary injectors with built in pneumatic Control thru software for
digital setting of septum purge gas as standard
Temp. range : Room temp + 5 oC to 450 oC in steps of 1oC
Heating rate : 50oC to 450oC within 3 minutes
Cooling rate : 450oC to 50oC within 5 minutes
Heating program: max. Heating rate120 oC /minute.
Should be configured with Back Flush option.
For 2 way split, for splitting flow between FID & MS detector
Flame Ionisation Detector
48







Type
:High sensitivity auto-ranging
Temp. Range
:Up to 450oC in steps of 1oC
Detection Limit
: 3 pg C/sec or better.
Linear Dynamic Range :106
Suitable for both capillary & OCI/PTV column application; totally software controlled
Detector gas is controlled electronically by pneumatic Control thru software
Fast Automatic Flameout detection and efficient automatic re-ignition
Electron capture detector (ECD)
 High sensitivity and excellent selectivity
 High operating temperature for maximum stability
 PPC pneumatics – software flow control of makeup gas
 Source 15 mCi 63Ni
 Temperature protect ~ 450 ˚C by software
 Carrier gas Either Ar/CH4 or N2
 Operating temperature ~100 ˚C to 450 ˚C in 1 ˚C increments
 Minimum detectable quantity < 0.05 pg perchloroethylene with argon/methane or nitrogen
 Linearity > 104
 Makeup gas Standard
Turbo Molecular Pump
 Vacuum System should be with turbo molecular pump having capacity of 250 L/min, with aircooled high vacuum pump, with control and safety interlocks integrated into the system.
Library
 Latest Edition library (NIST library as well as Wiley Library). Certificate of originality of the libraries
should be attached.
Software
The software should be a single point control of GC- MSD system and its modules with an assistant bar
showing operating procedures graphically and a wizard function that helps enter complicated parameters.
These make it easy for even first-time users to use the software. In addition, should be controlling
pretreatment accessories, such as headspace sampling unit, the software should allow continuous
automatic operation, while using self-diagnostic function of the software validation assistance. If a data
problem occurs, the analysis can also be automatically stopped to prevent wasting precious samples.
Since measurement parameters and data analysis parameters can be controlled using a single method file
and data files include instrument history information, it is capable of supporting GLP compliance and other
requirements. Operating System should be Microsoft Windows 2000 / Windows XP / Windows Vista.
Should have feature of Automatic Adjustment of Retention Time, creation of Automatic SIM table as
standard software feature. It should also have features for data acquisition, control, chromatographic data
evaluation and reporting sequencing


Accessories
Suitable On-line UPS with 60 minutes back up, for GCMS and HS system.
Filled Helium, Nitrogen, and Hydrogen Gas Cylinders & Zero Air Cylinder with regulators for the
49











6.
UV-VIS Double beam
Spectrophotometer with
temperature control and
data management system
operation of GCMS with all above accessories.
Gas purification System for all gases
Complete Gas station for connecting between Gas Cylinders & GCMS.
Intel Core i5 processer PC (HP/Dell), RAM = 8 GB, TFT Color Monitor = 19 inches, DVD
Writer/Player, Two Speakers, Graphic Card with Licensed Microsoft Operating System (latest )
with backup copies in DVD/ CD from factory itself.
Licensed Windows Based Software for system functions including control of all accessories, as
well as for Data Processing & Data acquisition of System with original copy in CD/DVD with
provision of future up gradation should be provided.
0.5µl, 1 µl, 2 µl, 5 µl, 10 µl Syringes (2 each)
Ferrules for columns for use with FID (20 Nos); Ferrules for columns for use with MSD (20
Nos);Non-stick Inlet Septa (50Nos); Column nuts (2 Nos); deactivated liners (1 no); O-rings for
liners (20 nos).
Filament (2 no’s), Split Liners (10 No’s.), Respective autosampler Vials 1000 no’s each with Septa
& Screw cap, Vacuum Pump Oil (1 Ltr)
Installation should include demonstration of application on real samples and training of staff.
Necessary reagents etc. for demonstration should be provided by the vendor.
User manual
User list with name, email and telephone number of user of the quoted model.
Quality Certification: System should have EU, CE and ISO certification.
-Microprocessor based UV-VIS spectrophotometer for photometric analysis(Absorption and
transmittance),spectral analysis, quantitative determination time scan, DNA/protein quantitation in stand
alone and PC mode
-Peltier based temperature control
0
-Temperature range 15-50 C
-High resolution LCD display with dedicated key pad
-Photometric system-Double beam optics with silicon photodiode
-Wavelength range 190-1100nm
-Spectral band width ≤2nm over complete range
-Resolution 0.1nm
-Wavelength accuracy ≤± 0.2nm for entire range with automatic wavelength correction
-Wavelength reproducibility±0.1nm
-Photometric range:Absorbance0.10-2.0, Transmittance 0-200%
-Photometric accuracy ±0.002abs(0-0.5abs) and±0.004abs(0.5-1.0abs)
-Photometric repeatability ±0.001 abs(0-0.5abs) and±0.002 abs(0.5-1.0abs) and 0.15%T(0-100%)
-Noise level ≤0.001 abs(500-700nm)
-Display :four digit LCD display
-Baseline flatness≤0.001 abs(190-1100nm)
50
7.
Atomic Absorption
Spectrophotometer with
fume hood
-Baseline stability<0.01 abs/h above 500nm
-Scanning speed 1500 or more to 2nm per minute
-Light source:20W halogen lamp and deuterium lamp(extra one lamp each in addition to the installed one),
auto switchover according to wavelength
-Built in validation, calibration and diagnostic program
PC interphase:RS 232
-Application software for analysis
-Branded computer:Intel core i5 processor,4GB DDR3rAM,500GBHDD , two or more USB ports in front
and four at back,Internet keyboard, optical mouse,17inch LCD color monitor,Windows XP 7,MS office and
antivirus software
-Pendrive 8GB(2)
-Branded laser printer(B&W) atleast 20ppm
-Compliance certificate
-2.0 KVA UPS certificate
 Fully automated personal computer controlled integrated Atomic Absorption Double Beam
Spectrometer.
 System with Wavelength Range 190 – 900 nm, with automatic changeover between Flame &
Furnace Mode along with Zeeman background correction for graphite furnace and Deuterium/
Zeeman background correction for flame.
 Echelle grating/ Czerny Turner Type/ Diffraction grating used with dual blazed and ruling density
[RLD (Reciprocal Linear Dispersion) 1.6 nm/mm] or Better
 Spectral bandwidths of 3 different types programmable through software using auto slit selection
mode.
 6 or more lamps position for flame and furnance with automatic lamp holder with computer
controlled lamp selection, its alignment and automatic optimization of energy using cooled lamps.
 Built in power supply for Ultra/EDL/Super/equivalent like special lamps to enhance sensitivity.
 Selection of single beam for GFA mode.
 The system should be integrated for both Flame & Furnace with built in Atomizer and changeover
should be controlled through software.
 The Detector used shall be Solid State Detector/ PMT (190 – 900 nm) having high quantum
efficiency.
 Graphite furnace System for Trace analysis facilities (sub ppb) with furnace Head, Power Supply
(230 Volts/ 50 Hz), and Furnace Auto sampler (capacity at least 50 Samples).
 Graphite Furnace Atomizer > 2600 oC or better.
 Built in Camera/Optical sensor in Graphite Furnace to display actual sample introduction and
method Optimization.
 Total Gas Flow Control System to maintain gas flows (Ratio of fuel/oxidant) at set levels even
when subjected to outside variations like nebulizer adjustments.
 Two Burner Head should be supplied; one for Air Acetylene (100mm) & Other for N2O burner
head (50 mm)
51




















Automatic Gas Flow adjustment during change over between air C2H2 and N2O
All safety interlocks like Burner head Interlock, Drain Interlock etc to built-in.
Adjustable nebulizer to take analysis with acids, corrosive samples including HF.
Carbon filled PPS Spray Chamber to analyze all types of samples, has high mechanical strength
and fast drainage characteristics
Fully Computer controlled Spectrometer for all major accessories including Graphite Furnace,
Burner Heads, Auto sampler etc under software control
Integral Furnace Auto sampler with Graphite Furnace for 50 or more samples delivery up to 50µl
with increment of 0.1 µl, automatic replicate analyzer. Auto Sampler should allow dilution.
Intel Core i5 processer PC (HP/Dell), RAM = 8 GB, TFT Color Monitor = 19 inches, DVD
Writer/Player, Two Speakers, Graphic Card with Licensed Microsoft Operating System (latest )
with backup copies in DVD/ CD.
Licensed Windows Based Software for AAS system functions including control of all accessories,
both of single element or multi-elements methods for Flame/ Graphite Furnace as well as for Data
Processing & Data acquisition of AAS System with original copy in CD/DVD with provision of
future up gradation should be provided.
Printer HP Color Ink Jet Printer.
Auto parameter selection for method development, automatic selection of stored methods,
automatic selection of flame conditions. Graphite furnace and MHS/HVG Techniques, Burner head
position is stored with method, auto optimization of flame, online sensitive context help, and user
selectable statistics for SD/ Percentage RSD, built in reporting user format, mouse operation, and
software available in CD form.
Gas Pressure Regulators: One each
Double Stage Gas Pressure Regulators with Stainless Steel Diaphragm, for Ultra High Purity
Grade gases each for Acetylene, Nitrous Oxide and Argon with necessary SS tubing and fittings
for connecting these to Gas Cylinders.
Vendor should quote MHS/HVG for analysis of hydride forming element.
Vendor should quote Individual coded HCL Lamp Zn, Co, Cu, Al, Ni, Ca, Cr and Mg,
Ultra/EDL/Super/equivalent like Special lamp for As, Hg, Cd, Pb.
Vendor should quote Indian component part like C2H2 gas Cylinder with regulator, N2O gar
Cylinder, Ar gas cylinder with regulator, Fume Hood (SS) with fan and fitting hardware required for
quoted AAS unit.
NIST traceable Standards (like from sigma etc) for each element separately 100 ml (1000ppm)
each.
Compatible 20 KVA on Line UPS with at least 30 min back up for Flame and for Furnace mode.
Vendor should quote Following Imported Items:
 N2O regulator with Heated Assembly system.
 Air Compressor Oil Free, Noise less, with air purifiers and moisture trap Circulating
Refrigerated Chiller
Installation should include demonstration of application on real samples and training of staff.
Necessary reagents etc. for demonstration should be provided by the vendor.
52

O-Ring kit for Nebulizer, Burner Head O ring, Gasket End Cap O ring, Nebulizer spacer, Gasket
End cap Corkprene, Cleaner N2O burner head, Contact Cylinders (5 No’s.), sample capillary 2
no’s for each volume, Graphite tubes 20 no’s, Autosampler cups for graphite furnace 1000 no’s for
each volume..
 Vendor should quote fume hood for sample preparation. It should be One-piece molded fiberglass
liner and pre-set baffle, working space approx. 125 cm X 60cm, should have international
certification such as - ASHRAE 110-1995, CFR 29, Part 1910, NFPA 45-2011, SEFA 1-2010 etc.
system should be supplied with solid epoxy resin. Sash should be tempered safely glass. Vender
will be responsible for ducting approximately 80 running feet of FRP along with arrangement to
prevent bird entry in pipe exhaust. Blower should be compatible to provide suction of 100 CFM. Air
flow volumetric rate 595 CFM.
 User manual
 User list with name, email and telephone number of user of the quoted model.
 Quality Certification: System should have EU, CE and ISO certification.
Electronic semi microbalance having maximum capacity of approx. 120g.
Readability: 0.01 mg
Repeatability (sd) : ~ 0.04 mg
Linearity: ~ 0.1 mg
Sensitivity temperature drift (10-30°C): 2 ppm/ °C
Stabilization time: ~ 8 s
Weighing pan dimensions: ~ ø 80 mm
Should have fully automatic time and temperature-controlled internal adjustment.
Should be made up of single mono-bloc block rust-proof metal alloy.
Should have tare facility.
Built in date and time function.
High-precision weighing cell with constant accuracy over the entire weighing range.
Connectivity to pc as well as printer.
AC adapter to run on main supply with overload protection.
Should be Programmable 3 Smart Keys for shortcut access to applications.
Quality Certification: System should have EU, CE and ISO certification.
User list with name, email and telephone number of user of the quoted model.
8.
Semi-Micro Weighing
Balance

















9.
Inverted Microscope with
Phase Contrast and CCD
Camera
Microscope Body: Microscope body with Infinity optical corrected system, facility for 2way either
(100/0,80/20)or (100/0, 50/50) light distribution, up/down focusing with course and fine knobs, side port for
attaching digital camera upgradable to one additional port for another camera, binocular tube with built-in
Bertrand lens and dark slide shutter along with dioptre adjustment facility.
Condenser: Universal turret condenser with long working distance of 72 mm or more and with NA 0.3-0.5,
adjustable field iris diaphragm & with 6 positions for optical devices.
Illumination: 12 V 100W pre-centered Halogen Illumination or LED.
Eyepiece: Paired 10X Eyepiece with F.O.V 22-25 mm or better and dioptre adjustment facility on both
eyes.
53
Nosepiece: Quintuple/Sextuple revolving nosepiece to accommodate 5/6 objective lenses at a time.
Mechanical Stage: Attached XY mechanical stage with flexible right-hand controls; Universal holder for the
attachment terasaki plate, slide, 35 mm dia petri dish, tissue culture flasks.
Objectives: High performance long working distance objective lenses 4X, 10X, 20X, 40X, and 60X suitable
for bright field and Phase Contrast application.
Achromate 4X (N.A~ 0.10)
Fluorescence grade 10X PH (N.A~ 0.25 or better) for BF and PH
Fluorescence grade 20X PH (N.A~ 0.45 or better) for BF and PH with iris correction ring.
Long working distance fluorescence grade 40X (N.A~ 0.60 or better) for BF and PH with iris correction
ring.
Long working distance fluorescence grade 60X (N.A~ 0.70 or better) for BF with iris correction ring.
Digital camera:
Digital high resolution color camera capable of handling bright field, phase contrast images. Should with
2/3” high density CCD chip with 5 mega pixels or higher. Live frame rate, at least 30 fps or higher. Binning
should be 2X2, 3X3, 4X4 in full colour with exposure of 1/20,000s to 8s in manual mode. Software should
come along with camera for acquiring, measurements, time lapse imaging, multi channel imaging, merging
& capturing of images. Should capable to take image on Monochrome & color mode.
Data Collection: Latest branded computer with Windows 7 professional or better, intel i5 processor, 4 GB
RAM, DVD writer, 1TB HDD 2.0” TFT monitor along with UPS and multimedia kit.
Software: Software should be capable to capture and transfer the image. Also capable of recording movie.
Annotation, point to point measurement, scale bar and calibration features should be incorporated.
Quality Certification: System should have EU, CE and ISO certification.
User list with name, email and telephone number of user of the quoted model.
Note: * The Microscope, camera & software should be from the same make for better compatibility and up
gradation.
* Onsite Technical demonstration after technical bid.
10.
Refrigerated Out-swing
Centrifuge
1. Acceleration time to max. speed between 10-15s.
2. SOFT function to Accelerate and decelerate gently.
3. Must have “At set rpm” function which enables timer countdown to be started only when selected
speed is achieved.
4. Must have digital display of time, speed (rpm/rcf) and temperature.
5. Should have temperature range in between -5ºC to +40ºC. .
6. Able to switch display between rcf and rpm speed setting.
7. Separate short spin key.
8. Low noise levels less than 55db at max speed.
9. Automatic motorised locking when lid almost closed.
10. Suitable branded voltage stabilizer with required power as required by the instrument
11. Rotor
54
11.
o


-150 C deep freezer
(i)
Swing head 8 x 15 ml rotor with adaptor for 7ml and 5ml with approx. speed of 4500 rpm
Quality Certification: System should have FDA approved or EU-CE and ISO certification.
User list with name, email and telephone number of user of the quoted model.
 Inner Temperature should be maintained continuously minimum -150°C.
 Capacity: 120 Liters and above.
 Pt1000 Temperature sensor.
 Microprocessor temperature control with LED Digital Display & keypad input for accurate
temperature control (1°C increments).
 Interior & Exterior of Acrylic finish baked steel.
 One outer door with latch integrated lock & Inner lid.
 Alarms: High, Low temperature, Power failure alarm, Door open alarm and malfunction buzzer
alarm.
 Should have high efficiency oil separator that effectively separates lubricant oil from refrigerant
that prevents clogging of compressor.
 Foamed in place polyurethane insulation minimum168mm thick.
 Alarm lamp with intermittent buzzer sound (for Temp., Filter, Power failure etc)
 Remote alarm interface.
 Microprocessor controlled Filter clogged check function.
 Self-diagnostic function.
 Compressor based cooling.
 CFC-free, HCFC free.
 Access port.
 Preferable Accessories: LN2-backup system.
 Stabilizer: Should be supplied with suitable voltage stabilizer of sufficient capacity.
 Machine should work on single phase 220 V 50 Hz power supply
 Quality Certification: System should have EU, CE and ISO certification.
 User list with name, email and telephone number of user of the quoted model.
Tender Group – Patho – Histo
1.
Slide Warming Plate
-
0
Temperature range – room temperature to 80 C
0
Programmable temperature control in increments of 1 C
Digital temperature display
Black, scratch resistant surface
Capable of holding at least 40 slides at one time
Size – 600 mm x 150 mm or similar
55
2.
Slide Filing Cabinet
3.
Orbital Shaker (Nonincubated)
4.
Gross Station
-
Inclusive of security mechanisms against overheating
220 V-240 V/ 50 – 60 Hz
Holding Capacity - 50,000 slides of size (25x75mm) in vertical position
Wheels for movement
Double door with chrome plated handle and lock
Made of aluminum / stainless steel
1. Stainless steel platform with corrugated rubber mat to prevent slipping and spillage
2. Platform size: 12-15 inches x 12 – 15 inches
3. Speed range – 10-150 rpm
4. Continuous run of
5. Safe for cold room/ fridge use
6. Orbit – 15 mm or higher
7. Microprocessor control of speed and time
8. Manual control by front panel for override of earlier speed
9. Operation: 220 V/ 50 Hz
10. Certification- CE/ UL essential
 Retractable acrylic side splash shields
 Units with fixed-height work surface
 Fixed-height units to have a work surface height -factory set to user specification
 Work surface height within range of 33.5 to 45.5" (85.1 to 115.6 cm); 36" (91.4cm)
 Deep sink with cold/hot water faucet
 Hands-free proximity sensing controls for cold/hot water faucet, built-in table rinse, and disposal
 Manual control of taps essential
 Abundant light directed to the work surface
 Vacuum breaker-protected water supply
 Integral centimeter ruler on front lip of tabletop, magnetic instrument bar and paper towel dispenser
 Built-in end table rinse that washes down work surfaces quickly
 Programmable microprocessor allows clock time to be changed and the filter replacement alarm to be
reset
 Recirculation exhaust with formaldehyde neutralizing filters and an integral blower
 Standard Type 304 or 316 stainless-steel work surfaces and panels
 Extruded corrosion resistant aluminum frame designed to distribute weight evenly, stand up to heavy
use, resist corrosion, add durability and minimize unit weight
 Unit to fit through a standard 32" (81.3cm) doorway
 The two assemblies link firmly with easy-to-assemble integral cam latches
 Unit to connect to the facility cold/hot water supplies and drain
 Units to have hard wired to the facility electrical system
• 220 – 240V, 50Hz,
• 19mm hot and cold water supply lines with shutoff valves and 33 mm drain line must be supplied
56
 13mm industrial-grade flexible hoses with 19mm female hose fittings are supplied for connection to
water supply lines
 38mm I.D. reinforced flexible hose is provided for connection to facility drain line.
 Camera should be of high QUALITY capable of IMAGES as below:
o
440.000 pixel images.
o 18 time optical zoom ensuring images of specimen from 2x3 cm up to 40x60 cm.
o 3 preset color filters for different types of specimen
 Certification : ISO, FDA/CE is mandatory
 Additional Accessories to be included:
a) Online UPS – 3 KVA with inbuilt batteries
b) Blue Vinyl/Polyethylene Dissecting Board
c) 1 no. Magnifying lens mounted on adjustable arm.
d) Magnetic Instruments bar
e) Replacement Filters- 6 nos.
5.
Waste Tray for Manual
Rotary Microtome
6.
Block Filing Cabinet
7.
Automated Tissue
Processor with Fume
Control, Bench Top
Section waste tray to fit with existing manual microtome (make Leica, model no RM2125)
1. Anti-static surface
2. Easy to clean
-
Holding Capacity - 20,000 blocks in numerical manner
Block type – block embedded in embedding rings/ disposable cassettes
Wheels for movement
Double door with chrome plated handle and lock
Made of aluminum / stainless steel
1. Fully programmable automatic tissue processor with microprocessor control
2. Carousel type, bench top model with lid, movable on rollers
3. Capable of running 2 cassette holding baskets simultaneously
4. Programmable display and touch pad keyboard
5. Electromagnetic motors for agitation and transport of cassette baskets
6. Both automatic and manual operation modes.
7. Number of reagent stations -09 (nine)
8. Reagent containers -9 in number, poly propylene / metal, must be solvent/reagent resistant, with
individual lids
9. Capacity of reagent containers: minimum of 1.8 litres
10. Cassette holding baskets - 2 in number, each with holding capacity of minimum 100 cassettes,
preferably more
11. Electrically heated wax baths - 3 in number
0
12. Temperature range of wax baths: 50-65 C
0
0
13. Cut off temperature of wax bath: 75 C (±4 C)
14. Wax bath container should be double walled metal.
15. Separate temperature control of each paraffin bath.
16. Microprocessor control of immersion time per station.
57
8.
Tissue Flotation Bath
9.
Spectrum Gold Filter for
existing Upright Trinocular
Research Fluorescent
Microscope with Digital
Image Analysis system
10.
Electrically operated glass
etching hand held tool
-
17. Spiral agitation or vaccum on all reagent stations for quality tissue processing
18. Additional selectable options for agitation of cassette holding basket in non-submerged state prior
to reagent changeover for reduced reagent carry over: desirable.
19. Automatic cut off device at the end of processing cycle, with cassette holding basket in second
and third wax bath until it is removed.
20. Automatic immersion of tissue baskets in case of power failure by built in battery.
21. Manual basket removal during power failure.
22. Safety indication for non-melted paraffin wax.
23. In case of solidification of wax due to power failure, unit should wait for solidified wax to melt
before resuming program where it stopped.
24. Possible process interruption for reloading or removal of specimens.
25. Programmable start delay for at least 7 days.
26. No of programs storable in memory: at least 9
27. The system should display information about instrument running status.
28. In built fume extraction system comprising of activated charcoal filter and exhaust fan.
29. Operation: 220-240V/50-60 Hz
30. Certification – essential, CE/ US FDA certificates, should be supplied with the instrument.
31. Essential accessories
a. Online UPS – 2 KVA or higher capacity capable of supporting function for at least 2 hours
duration.
b. Carbon filters – 01 in number in addition to that fitted in the instrument
c. Tissue basket – 01 in number
0
Temperature range – room temperature to 70 C
0
Programmable temperature control in increments of 1 C
Digital temperature display
Black color interior
Double layered container
With stainless steel lid
Inclusive of security mechanisms against overheating
Size – minimum 200 (Dia) x 70(Depth) x 40 (Rim) mm
220 V-240 V/ 50 – 60 Hz
User friendly emptying system – optional
Specification for Spectrum Gold filter for existing Upright Trinocular Research Fluorescent
Microscope with digital image Analysis system
1. Shemrock/ chroma/ equivalent
2. Exciter 534 nm
3. Emitter 572 nm
4. Dichroic 552 nm
5. Transmission avg >93%
6. Suitable for Alexa Flour 532 or similar wave length.
1. Pen shape for ergonomic efficiency
2. Casing- anodized aluminium
58
3. Capable of deep engraving, marking and labeling of glass
4. Weight less than 100 gms
5. Motor to switch off when not held in hand
6. Operation: 220V/ 50 Hz
Essential accessories: 10 tips compatible with the instrument
Tender Group – Patho–Hemato
11.
Ultrapure Type I Water
Purification System
12.
Fully Automated Microplate
ELISA Reader with printer
13.
Projection System for 7
Headed teaching Microscope
1.Integrated ultrapure water purification system which gives Type I water and should consist of pre
filtration unit, RO cartridge, EDI with activated carbon beads and polishing cartridge along with
30L PE tank and softener, direct ultra pure water purification unit ,tank etc
2.The quality of water should be suitable for use in HPLC,GC-MS and molecular biology
3.Flow rate upto1L/min
4.Output quality upto 18.25megaohm
5.Conductivity at 250C:0.05µS/cm
6.Resistivity at 250C 18.2Mcm
7.TOC(µg/l)<5ppb
8.Bacteria count,cfu/ml<1
9.Particulates (size>0.22µm):<1/ml
10. Pyrogens<0.001EU/ml
11. RNase<0.01ng/ml
12. DNase<4pg/µl
13. Alarm for filter replacement
14. User manual
15. Quality certification:System should have EU,CEand ISO certification.
1.
8-12 measuring channel & 1 reference channel
2.
Wave length range of 400-750nm with provision for fitting additional filters.
3.
Should have a minimum resolution of 0.001 OD and linearity up to 3.0 OD.
4.
Read within 10-15seconds
5.
Variable speed plate shaking capability
6.
Read 96 well micro plates
7.
At least 25 user defined programmes
8.
Data memory of at least last 15 plates
9.
Work on 180-260 V AC
10. Single channel pipette with adjustable volume (10-1000μl)
11. Integrated thermal printer
12. Ability to read flat,U or V bottom plates
13. USB 2 port for external computer control
14. Voltage stabilizer
48inches full HD flat TV H5 1 00 Series 5
HOM I Graphic Card 2GB with 1 VGA and HDMI port cable
59
Tender Group – Pathology – TT
14.
Upright LED microscope
with imaging system












Microscope Frame: Upright microscope with built-in Koehler illumination for transmitted light LED (pre
centered) with lifespan of at least 50,000 hrs or more.
Observation tube and Eyepieces: Trinocular observation tube with three way light distribution
(100:0/20:80 or 50:50/0:100). Eyepiece of 10X magnification with F.O.V 22mm or higher -2 nos with
both side diopter adjustment facility.
Mechanical Stage: Ceramic coated coaxial stage with right-hand drive control with two slide holder.
Condenser: Swing – out condenser
Nosepiece: Reversed Sextuple (Six position) revolving nosepiece.
Objectives: For Bright field: Plan Achromat 2X N.A 0.06, Plan Achromat 4X N.A 0.10,
Plan
Achromat
10X
N.A
0.25,
Plan
Achromat
20X
N.A
0.40,
Plan Fluor / Plan semi Apochromat 40X N.A 0.75 (spring loaded), Plan Fluor / Plan semi Apochromat
100X N.A 1.3 oil immersion (spring loaded).
Digital CMOS / CCD Camera system:
 High resolution scientific CMOS/CCD color camera
 Chip size should-be (36X23mm) / 2/3”with appropriate relay lens
 Resolution of at-least 12.0 MP or more
 Minimum 30 frame per second live display
 Projected area to be at least 70% of field of view.
 Camera should be capable to capture BF images.
 Microscope, camera and software should be from same manufacturer.
Image Analysis Software: Compatible software for Image analysis, overlaying multiple image,
automated multi wavelength capturing, side by side image comparison, snap /movie acquisition, and
time lapse at specified interval, interactive measurement functions. Microscope, camera and software
should be from same manufacturer.
Work station: Latest BRANDED computer with i5 processor, HDMI compatible 1GB graphic card for
fast data transfer, HDMI port, 8GB RAM, 1 TB HDD, DVD RW, with windows 8 OS, 18 inch TFT
screen, Branded 64” Color LED TV display monitor with HDMI Port , wireless keyboard, wireless
mouse and 2 KVA offline UPS.
The Microscope should have Safety measure to avoid accidental contact of Objective and slide
to prevent the damage to the sample and objective both.
CE,ISO and EC (European conformity ) / UL/FDA (CDRH) certification
Essential accessories/ installation terms:
 Wall mounted installation (of 64 inch LED frame) with wooden frame and sliding doors
 Table to house the microscope, computer, UPS.
 Cushion stool for person handling microscope
60
Tender Group – Patho– Cyto
15.
PH/ORP probe with Liquid
gel and polymer electrolyte
16.
Incubator (Table Top)
17.
Antigen Retrieval System
1 Digital Pen/Probe model with LCD display
2. pH range 0.0-14.0
3. Readability:- +-0.01
4. Accuracy:- +- 0.01
5. Suitable for automatic calibration and auto reorganization of the pH of buffers & chemical between
4.0-9.2 at temperature 20-50
pH
S. NO.
1.
Specification
Size Inside Chamber
(WxDxH)300mmx300mmx300mm
2.
S.S digital
3.
Air Circulating Fan
4.
Microprocessor PID control
0
5.
Temp- Ambient to 90±0.5 C
6.
220/230 volts
1. Microwave-based system
2. Programmable time and temperature control
3. Oven capacity – 20 to 30 ltrs
4. Digital display of time and temperature
5. Suitable to work on 220 V, single phase, 50 Hz, AC supply
Tender Group – Biochemistry
1.
Semi-Autoanalyser
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Lamp: Tungsten Halogen Lamp
Monochromatic and Bichromatic Measurements
Photometric range: 0 – 3.0 Ao with resolution of 0.0001 Ao
Zero drift and filter check facility, facility for light source off.
8 wavelength filters(± 10nm) : 340, 405,450,505/510,550,578,630, 680nm
LCD/ LED display
Operating environment : 15-300 C , Humidity- upto 80%
Assays: Absorbance, End Point, Fixed time, Kinetic , Turbidimetry
Blanking: option for Automatic, Water blanking, Reagent Blanking
Temprature control: RT, 25, 30, 370 C
Calibration: single point, 2 point & multipoint with display, Calibration types: linear, point to
point
12. Aspiration volume: 200µl -1000µl & option for vol calibration
13. Test methods: ≥ 200 user defined programmes
14. Quality control: Automatic QC calculations, L-J Chart, graph display, results, daily and monthly
61
data view
15. Should be FDA approved/ CE certified
16. Memory: minimum of 10000 sample results & minimum of 100 QC results (with retention
memory for at least 2 QC values per day)
17. Desirable: Option for short and long continuous washing programme for reaction cuvette/ flow cell
18. Built in thermal printer
19. CMC/ AMC as per the institutional rules
20. Accessories: UPS with atleast ½ hr battery backup, thermal printer rolls 25, suction tube 02 and
peristaltic pump tube 02, fuse 02.
21. Free installation & Demonstration
2.
Micro-Centrifuge
Performance:
 Temperature range of -10C to + 40C, which is modifiable during the operation run
 Centrifuge must have a “fast cool“ function where cooling process can be shortened
 Must have a standby cooling and heating mode up to 8 hours which enables cooling or heating even
when not in operation.
 Should have automatic temperature start up at a specific time to automatically pre-prepare
temperature before centrifugation
 Must be able to maintain at 4C at max. speed with maximum temperature control accuracy.
 Max speed of not less than 15,000 rpm with maximum speed control accuracy.
 Acceleration time to maximum speed should not be more than 15s for all rotors at max load and a
deceleration time of not be more than 15s with the standard 30 x 1.5/2ml rotor, but has option to
accelerate and decelerate gently for sensitive samples
 Timer for run can be set up to 99minutes continuous
 Preference for “At set rpm” function which enables timer countdown to be started only when selected
speed is achieved
General features:
 Must have digital display of time, speed and temperature
 Programmable time and speed using jog dials
 Must be able to store at least 20 routine procedures with programmable buttons for frequently used
programs in the first level
 Able to switch display between rcf and rpm speed setting
 Separate short spin key
 Low noise levels less than 65db at max speed
 Brushless maintenance free drive
 Automatic motorised locking when lid almost closed
Safety features:
 Must follow international safety standards set by IEC
 Rotor should be made of anodised aluminium to ensure chemical resistance
62





Chamber must be of stainless steel material
Rotor must be autoclavable to completely eliminate any contaminating material
Aerosol tightness of lid / chamber / rotor will be preferred to prevent contamination of biological
samples
Automatic imbalance detection
Automatic rotor recognition
Rotors:
 Fixed angle rotor to accommodate 1.5/2ml tubes
 Fixed angle rotor to accommodate 15/50ml Falcons or blood collection tubes when sleeves and
adapters are used
 Fixed angle rotor accommodating PCR strips
3.
Gradient Thermal Cycler

Gradient Thermal Cycler with Peltier heating and cooling based system. Power Supply: 220 -230
volt, 50–60 Hz
 The dual block should also have gradient capability which can be independently controlled for both
the blocks.
0
0
 Should have a maximum ramp rate of 5 C or more/second and average ramp rate of 3.0 C/sec
or more.
 Should have adjustable heated lid and also block & calculated temperature control modes.
0
 Should have a temperature range of 0-100 C
0
 Should have a temperature accuracy of ± 0.2 C or less
0
 Should have temperature uniformity of ± 0.4 C or less well to well within 10 seconds of arrival at
0
90 C.
0
 Should have a gradient range of 30-100 C and use dynamic ramping for gradient.
 Should have a LCD display and have USB ports.
 Should have a memory of >1000 programs with further expansion through a USB Flash drive for
transfer of files.
 Programmable, power-saving auto standby option when instrument is idle.
 Option of using the instrument through a PC should be there.
 Should be licensed for research.
 Should be supplied with 1 KVA online UPS with one hour power back-up
 Should have FDA and European CE Certification
Original company literature from principal company, manufacturer must be supplied; clearly
verifying all specifications.
63
Tender Group – Forensic Medicine
1.
Height Weight Machine





2.
Human Bone
Original)
(Adult
&
Height Adjustable Up to 8 Ft.
Weight Measuring Capacity Up to 0 to 150 Kg.
Standard Foot Space for Standing.
Aluminum Water Proof Strips.
Easy to Move and Portable in Nature.
NAME OF ITEM/S
i. Adult’s Human Skull (male)
3.
X-Ray View Box
4.
Digital Weighing Balance
Qty.
(in nos.)
10
ii. Adult’s Human Skull (female)
10
iii. Adult’s Human Pelvis (male)
10
iv. Adult’s Human Pelvis (female)
10
v. Adult Human Disarticulated Skelton Male
01
vi. Adult’s Human Disarticulated Skeleton Female
01
1. Should have double film size(28”x34”)capacity.
2. The equipment should have high level of control luminance, without flicker, from a unit that is easy
to clean and maintain.
3. The X-Ray viewing screen illumination should dimmable LED of minimum 60000 hours life and
shall work on single phase power supply.
4. Should have minimum 10000 Lux output adjustable.
5. Should have individual brightness and ON/OFF controls.
6. The front panel diffuser should be of a glare free type.
7. Should have clip less mechanism to hold and secure the X-Ray negative film when in use.
8. LED lamp should provide a uniform level of illumination across the entire front panel diffuser and
should be controlled by electronic step –less dimming controls to provide flicker free dimming from
maximum brightness to OFF.
9. Individual light control for each plates.
10. Equipment shall be elegant and compact.
11. Body should be made up of mild steel powder coated.
12. Should be grounded properly.
1. Maximum capacity: 220gm
2. Weighing platform dimensions: 90mm
3. Readability : 0.1mg
4. Repeatability : 0.1mg
5. Linearity: 0.2mg
64
6. Settling time: 2 s
7. Sensitivity Temperature Drift: 2ppm/deg. centigrade
8. Weight of Balance: 4.7kg(ME)/ 4.5 kg(ME-E)
9. Approved by weight and measure department by Govt. of India/State.
Tender Group – MIU
1.

Plotter Printer










2.
Photo Printer/Photo Inkjet
Printer
Capable of borderless printing large poster on Roll Paper and Water resistant Cloth Media
(Cotton-Polyester) (upto A ‘0” size)
Roll paper size 20 inch to 44 inch wide
PC Compatible – Window XP/7/8
Resolution 2400 x 1200 dpi or more
Ten or more colour printing with individual high capacity (300ml or more) pigment ink
Speed : Economy mode – 10 or more sq. meter/hr
Memory: 256 MB ore more
Connectivity: Parallel and serial high speed USB
Essential accessories –
Essential software for best quality printing
Operating Manual/CD
Power: 220 ± 20 volts
Voltage Stabilizer – 1.0 KVA (Branded)






Capable of Printing on glossy/Luster and matte paper
720 x 720 dpi or more
Semi-Auto Paper Loading
USB – High speed
Software – Windows XP/Window 7
Printing Paper size – Upto 6” x 8” inches or more,
- Capable of printing on Roll paper
 Printing Speed – 5 prints per minute or more
 Voltage: 220 ± 20 volts
 Essential accessories
- Paper tray/spacers
- Operating Manual
- Essential software
Tender Group – Micro
1.
Fluorescent Trinocular
Microscope
Specification for Upright Trinocular Research Fluorescent Microscope with Digital Image Analysis System
Magnification - 40x -1000x for observation
65
Optical system - infinity optical system with uniform illumination
EYEPIECE TUBE - TRINOCULAR TUBE WITH INCLINATION ANGLE OF 10-30o ALONGWITH
80:20/50:50
LIGHT DISTRUBUTION PORT FOR SIMULTANIOUS VIEW AND ATTACHING DIGITAL CAMERA AND
DOUBLE
PORT TO ATTACHED SECOND CAMERA.
EYEPIECE LENS - 10X (2PCS) WITH BOTH SIDES DIOPTER ADJUSTMENT ATLEAST (F.O.V. 25MM) OR
HIGHER SHOULD BE ANTI FUNGUS TYPE.
OBJECTIVE - HIGH PERFORMANCE OBJECTIVE SUITABLE FOR BRIGHT FIELD, FLUORESCENCE
MICROSCOPE
Plan Achromat 4x NA 0.10, WD 30.00 mm or better
Plan Achromat 10x NA 0.25, WD 10.50 mm or better
Plan Fluor 20x NA 0.50, WD 2.10 mm or better
Plan Fluor 40x NA 0.75, WD 0.66 mm spring loaded or better
Plan Flour 100x NA 1.30, WD 0.16 mm, Oil, Spring loaded or better
NOSE PIECE - SEXTUPLE NOSEPIECE. TO ACCOMADATE SIX OBJECTIVES
COARSE/FINE FOCUSING - FINE 0.1MM PER ROTATION/COARSE 13.8MMPER ROTATION. COARSE
MOTION TORQUE ADJUSTABLE.REFOCUSSING STOPPER SHOULD BE INCORPORATED.
MECHANICAL STAGE - SUPER HARD CERAMIC COATED SURFACE, STAGE HANDLE HEIGHT &
TENSION SHOULD BE ADJUSTABLE. LOW POSITIONED COAXIAL X(78MM) AND Y(54MM) MOTION
CONTROL ON RIGHTHAND SIDE WITH CAPACITY TO HOLD TWO SLIDE GLASS AT A TIME.
IMAGE CAPTURE BUTTON - IMAGE CAPTURE BUTTON INBUILT FOR QUICK IMAGE CAPTURING
CONDENSER - ABBE CONDENSER
ILLUMINATION - 12V-100W HALOGEN LAMP PRECENTERED AND PREFOCUSED.
FLUORESCENE ATTACHMENT:120 / 130W MERCURY/METAL HALIDE ILLUMINATION SHOULD HOLD SIX FLUORESCENCE FILTER
BLOCKS
IN ROTATING TURRET, PRE- CENTERED LIGHT WITH 2000 HRS LAMP LIFE.Lamp should be out-side of
the Microscope body.
SEMROCKOR/EQUIVALENT FILTERS
DAPI- Exciter 387nm, Emitter 415nm, & Dichroic 409nm with Transmission avg >93% 415-950nm.
SPECTRUM GREEN - Exciter 494nm, Emitter 527nm, & Dichroic 506nm with Transmission avg >93% 513950nm.
SPECTRUM RED - Exciter 586nm, Emitter 628nm, & Dichroic 605nm with Transmission avg >90% 415-950nm.
DIGITAL CAMERA SYSTEM:
(A)Digital Monochrome camera for fluorescence imaging
66
2.
Brightfeild Trinocular
Microscope
Type of sensor: high sensitive, high speed, low noise monochrome CMOS/CCD sensor
Quantum efficiency: > 75%
Cooling: Electronic cooling
Live display: 15 FPS – 45 FPS at full frame or different frame.
Full well capacity: more than 50000 eRead out noise: 2.2 eOptical interface: F‐mount adapter,
PC interface: USB 3.0
All the necessary cables/ power supply must be included
(B) Digital SLR camera for Brightfield imaging
With at least 16.2 million effective pixel resolution, Sensitivity- ISO 100 to 6400 in steps of 1/3,
1/2, 4 GB compact flash card, 3’’ LCD Monitor allows up to 170-degree viewing angle, horizontal opening type
vari-angle LCD, USB interface cable with software CD for downloading the images on PC, Lithium-ION
Rechargeable battery with charger, Along with compatible relay lens and Adapters.
Image Analysis Software should be with following features:
Acquisition and device control through four-dimensional acquisition.
Image Acquistion,
Time Lapse Imaging,
Z-Stack, Multi-channel Fluorescence, Annotation,
2D / 3D View, ND Viewer,
Filter,
Morphology, Large Image,
Macro,
Segmentation,
Auto-measurement,
Report Generator facility,
Data Base, Vector layer & Multi-Dimensional File Format (ND format)
Note:The Microscope, fluorescence, camera and image analysis software should be of same make and
manufacturer for future upgradability and flexibility. This is a very essential terms to be followed.
Data Collection and processing unit:
Branded i5 processor, 4 GB RAM, DVD Writer,1 TB or higher HDD, 18.5”TFT Monitor, Key board, Mouse along
with UPS
BRIGHTFIELD TRINOUCLAR MICROSCOPE WITH PHOTOGRAPHIC ATTACHEMENT
- Body – Almunium Die cast with ergonomic design
- Magnification 40-1500X
- Illumination: Should provide universal power supply (100v-240v) for 6v 20w
Illuminator, fitted with aspheric fields lens, must have dust cover & plano-concave
mirror unit.
- Objectives: Should have 4x(N.A.0.1), 10 X (N.A. 0.25), 40 X (N.A. 0.65) & 100 X
(N.A. 1.25) objectives.
 Objective lenses should be plano-achromatic – for flat and sharp images in the entire field of view.
 Parafocality & centring should be maintained during interchangeability of objectives.
67
- Eye piece lens: Should be 10 X widefield colour compensating & F.N. 18mm,
Eye piece lenses must be guarded.
- Trinocular observation tubes with binocular tube inclination of 30 or 45 degree & 360
Degree rotable and with inter-pupillary distange adjustment range appx. 50-75mm
- Trinocular eye piece tube should be attached with a digital colour camera
 The photographic unit should have a control unit for focusing & viewing
On built in LCD (Microimage projection system)
 Optical images can be clicked in scene mode and stored.
- Condenser : Abbe condenser, N.A. (1.25), with aperture iris diaphragm.
Optical assembles including eyepiece, objectives & observation tube should be antifungal treated.
- Stage : mechanical stage movement 76 X 40mm, with scale.
 Stage size 120 X 132 mm or 155 X 134.
- Should be an ISO 9001-2000 certified company
- Tenderer must have a service network & users list.
3.
4.
Refrigerator Double Door
Binocular Microscope
1. Vertical double walled
2. Double doors
3. Capacity:- 350 - 400 Ltr. Approx.
0
4. Accuracy = 1.0 C
5. Frost Frees auto
6. Safety fuse, shock protection and locking facility
7. Inbuilt voltage stabilizer
Salient and Unique Features Fixed Koehler Binocular Laboratory Microscope for Transmitted Light Bright
field studies with HAL Illumination and LED Warm light illumination and Eyepiece with 100x Dry objective
The microscope should be capable of Bright field and should be upgradeable to Phase contrast and
Fluorescence microscopy.
The microscope should have the following technical features:
 Ergonomically designed rugged stand for longtime comfortable usage. Carrying handle fully integrated
into the stand.

Microscope should be with Infinity Color Corrected System Optics with anti-fungus treatment.

Built-in Transmitted light Modular designed illumination with 6V 30W halogen lamp with easy lamp
changing and should have provision to replace the same with white light Long Life LED- warm-light,
3200K illumination by the user. Both can be used alternatively

Intensity level display by means of a 5-element Display on both sides of the stand via live blue LEDs.
Protects lamp life by ensuring that all instruments are turned off when not in use. External main power
supply with electronic main control from 110V to 240V.
68

Quadruple reverse nosepiece tilted backwards ( to accommodate 4 objectives) with precision click
stops for easy rotation. Allows easy access to stage and protects objectives.

ABBE Condenser with numerical aperture 1.25 with built-in aperture diaphragm.

Long-Life Stage coating Dimensions (width x depth) 140 x 135 mm; Slide Stage should have ball
bearing specimen holder and should have right handed coaxial X and Y movement controls on the right
hand side and specimen holder with spring clip on the left side; The traveling range of the stage should
be 75 x 30mm with vernier marking. easy to read vernier scales for precise and fast repositioning of
sample.

The stage focus movement range should be 15mm or more with coaxial coarse and fine focus knobs on
either side of the stand. The minimum step size of the fine focus should be 2 micron or better. Focus
stop mechanism to protect slide damage should be available.

Inclined Binocular tube with 30deg swiveling eyepiece tube and adjustable viewing suitable for
eyepieces up to field of view 20mm height of at least 40mm (Siedentopf tube, viewing heights 385 to
425mm). Interpupillary distance should be variable between 48 to 75 mm or better. Binocular tube
should be fully made of metallic and should not have any plastic covers.
Paired Eyepieces with 10x magnification, field of view 18mm and should be suitable for spectacle
wearers. Both eyepieces should be with front focusable eye lenses with
+5 dioptre correction.

5.
B.O.D Incubator

High contrast Fully Plan Achromatic objectives, 4x/0.10, 10x/0.25, 40x/0.65 and 100x/1.25 oil. 40x and
100x front optics are spring loaded. All the objectives should be of parafocal corrected for easy
specimen focusing in various magnifications.

Microscope should be upgradeable for Dark field, Phase contrast and incident light LED fluorescence
techniques.

Microscope should include daylight and green filters, immersion oil and dust cover









o
o
B.O.D. Incubator size 10 cub. feet temperature range +5 C to 55 C.
Double door, inner door made of glass.
Thermostat regulated with automatic switch over from cold to hot & vice versa.
Pilot light to indicate the working unit.
Fitted with 60 Watt bulb in chamber with independent switch out side, with separate dial
thermometer and temperature control knob.
Fitted with circulation fans.
Inside chamber and racks made of stainless steel.
Glass dial thermometer inside the chamber.
Should be an ISO 9001-2000 certified Company
69

Tenderer must have service network and users list
Safety Care: Built in temp deviation audio visual alarm. Safety thermostat for over shoot temp. Cut off
system HRC fuses for compressor heater & main, time delay circuit for safety of compressor.





6.
Microwave Oven
7.
Vertical Autoclave
1.
2.
3.
8.
VDRL Shaker Digital







9.
Water Bath
Inner size of the water chamber: Capacity:
Temperature range:
Accuracy:
30-35-Ltr
5 star
Should have timer display
Should have Power option display
Option to set timer

Different power output option
Should be a vertical autoclave having inner dimensions of 350 x 550mm.
Should be double walled with outer stainless steel 304 & inner stainless steel 18 SWG sheet.
Lid should be made of S.S.plate & tightened by radial locking system with foot lifting
arrangement to open the lid.
4.
Should be fitted with joint less silicon rubber gasket.
5.
Should be equipped with pressure gauge, steam release valves and safety valve.
6.
Should be fitted with water level arrangement to indicate water position inside the boiler.
7.
Should be fitted with automatic low water level cut of devise.
8.
Should be fitted with a digital timer and a digital temperature indicator.
9.
Should have an automated pressure switch which can be set from 5 psi to 20 psi ± 2 psi &
should have drain.
10.
Should have SS perforated basket.
11.
Should have a cord & plug to work on 220 volts and 50 cycle AC supply.
12.
Should be fitted with 3 KW ISI marked immersion type heating element.
13.
Autoclave to be supplied with 4 no’s silicon rubber joint less gasket and 6 no’s 3 KW ISI
marked immersion type heating element.
Manufacturer/Supplier should have ISO certification for quality standards.
Should have plateform size 12”x12” Approx.
Should have dimension of 300 x 300 x 125mm Apporx.
Speed range should be 80-200 RPM
Digital count down timer should have 15 min – (With automatic switch off)
Shaking Orbit should be 10 mm
Weight, not more than 3 Kg
Power supply should be 220-240 V, 50 Hz
400 X 300 X 175 mm (LxBxD) Aprox.
20-25 lts
ambient to 100oC
± 0.1 - 0.5oC
70
10.
11.
Clinical Centrifuge Table
Top
Inspissator
Temperature control method:
Sensor:
Mount:
Inner body:
Outer body:
Flange:
Insulation:
Display and controller:
Microprocessor PID controlled
PT. 100
Table top.
S.S. (304)
M.S. with powder coating.
S.S. (304)
PUF insulation
Digital
Input voltage:
220V, 50 Hz.
1.
2.
3.
4.
5.
6.
7.
8.
9.
1.
2.
3.
4.
5.
6.
7.
1.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
Routinely used table top model
Should have digital display of speed / timer
Should have speed regulator step less
Maximum speed should be up to 4000 RPM to 5000 RPM
Should be able to detect imbalance
Should have lid lock for safe run.
Should be able to adapt various capacity rotors.
Rotors
24x15ml angle head for holding tubes
A shallow stainless steel tray should be rested inside a tank containing water.
The whole undersurface of the tray must be in contact with water at a constant temperature which
ensures that the temperature of the McCartney bottles with media is also constant.
The surface of the tray is a series of sloping steps (at 9 degree angle above the horizontal) and will
hold 162 universal containers.
A blanket should be placed over the containers to exclude draughts and a quilted cover provides
thermal insulation.
Both blanket and quilt are made from insect-resistant materials.
The temperature of the water under the tray is must be controlled by a digital immersion thermostat.
Accuracy and reproducibility of set temperature are ensured with the digital display
of actual and, at the touch of a button, set temperature.
The control unit should be mounted on a bridge plate over one end of the bath, from which heater;
stirrer and temperature sensors project down into the bath.
All moving parts should be incorporated in the control unit which removable for servicing.
The tray and tank are made of stainless steel and are fitted in an outer case of laminated wood.
A constant level device is fitted maintain the water level despite evaporation losses.
Std temperature must be 85ºc;
Operating temp. Range should be: ambient to 90ºC.;
It should have LED temperature display and Display resolution: 0.1c;
Voltage regulators of appropriate rating should be included for each item ton cope with
160-260 V.8
Uniformity: tray surface + or - 0.7c;
Heater power should be (approx.) 1.4Kw, 230V;
Tank capacity should be (approx.) 45 lit.
71
19.
20.
21.
22.
23.
24.
25.
12.
Egg Incubator
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
Working area should be approx 820/594 mm (length/width)
Overall dimensions should be approx 1040/600/380mm (l/w/h)
Over temperature protection should be fixed cut-out;
Electrical power: 220-240V 50/60 Hz, 1.5kW (approx.)
Approx.weight: 25-35 kgs.
Voltage regulator of appropriate rating should be included for each item to cope with
160 - 260 V.
The instrument should be rust free
Outer body should be made of MS sheet, duly pre-treated & finished with epoxy powder coated
paint.
The inner chamber should be made of aluminium sheet.
Door should be with double glass viewing windows to facilitate easy inspection of interior.
The chamber trays should have with manual tilting mechanism.
Water tank should be provided at bottom made of stainless steel 304 rust proofs and a water outlet
should be provided in the tank.
Water heater is fixed in the tank.
Air circulating fan should be present to ensure uniform temperature inside the chamber.
Thermostat regulated with automatic switch over from cold to hot & vice versa.
Pilot light to indicate the working unit.
Fitted with 60 Watt bulb in chamber with independent switch outside, with separate dial
thermometer and temperature control knob.
Fitted with circulation fans.
It Should have digital display of temprature .
Temperature range should be ambient to 70°C ± 0.5°C controlled by imported thermostat.
Control penal should be provided along with thermostat control knob, pilot light, main ON/OFF
switch etc.
Warranty should be 5 years from the date of installation.
Equipment is suitable to work on 230 volts, 50 Hz, single phase, AC supply.
It should have capacity of 100 eggs incubation.
72