Green Power 2.0 DELPHYS GP

Green Power 2.0 DELPHYS GP
Green Power 2.0
Three-phase UPS
DELPHYS GP from 160 to 500 kVA/kW
ultra high energy efficiency and maximum power availability up to 4 MW
The solution for
> Data centres
> Telecommunications
> Service sector
> IT Networks / Infrastructures
Attestations
B U R E A U
VERITAS
Green Power 2.0 is attested
by Bureau Veritas
gamme 305 a
Advantages
Energy saving + Full rated power = reduced TCO
Energy saving: high efficiency
without compromise
• Offers the highest efficiency in the market
using VFI – Double Conversion Mode, the
only UPS working-mode that assures total
load protection against all mains quality
problems.
• Ultra high efficiency output independently
tested and verified by an international
certification organization in a wide range of
load and voltage operating condition.
• Ultra high efficiency in VFI mode is
provided by an innovative topology (3-Level
technology) that has been developed for all
the Green Power UPS ranges.
Full rated power: kW=kVA
• No power downgrading when supplying the
latest generation of servers (leading or unity
power factor).
• Real full power, according to IEC 62040:
kW=kVA (unity power factor design) means
25% more active power available compared
to legacy UPS.
• Suitable also for leading power factor
loads down to 0.9 without apparent power
derating.
14
Catalogue 2013
Significant cost-saving (TCO)
• Maximum energy saving thanks to 96%
efficiency in true double conversion mode:
50% saving on energy losses compared
to legacy UPS gives significant savings in
energy bill.
• Up to 99% efficiency with Fast EcoMode.
• UPS “self-paying” with energy saving.
• Energy Saver mode for global efficiency
improvement on parallel systems.
• kW=kVA means maximum power available
with the same UPS rating: no overdesign
cost and therefore less €/kW.
• Upstream infrastructure cost optimization
(sources and distribution), thanks to high
performance IGBT rectifier.
• Extended battery life and performance:
- long life battery,
- very wide input voltage and frequency
acceptance, without battery use.
• EBS (Expert Battery System) charging
management improves battery service life.
• BHC INTERACTIVE: Accurate battery
monitoring with UPS interactivity for even
more prolonged service life.
Flywheel
COMPATIBLE
Better performance
than the EU Code of Conduct
on efficiency of AC UPS
Green Power 2.0
DELPHYS GP from 160 to 500 kVA/kW
Three-phase UPS
Parallel systems
Standard electrical features
Electrical options
To fulfil the most demanding needs for power
supply availability, flexibility and the installation
to be upgraded.
• Modular parallel configurations up to 4 MW,
development without constraint.
• Distributed or centralized bypass flexibility
to ensure a perfect compatibility with the
electrical infrastructure.
• Twin channel architecture with Static
Transfer Systems.
• Distributed or shared battery for energy
storage optimization on parallel systems.
• Dual input mains.
• Integrated maintenance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery
management.
• Redundant cooling.
• Battery temperature sensor.
• External maintenance bypass.
• Extended battery charger capability.
• Shared battery.
• Flywheel compatible.
• Galvanic isolation transformer.
• Backfeed isolation device.
• ACS synchronisation system.
• BHC Interactive.
• Fast EcoMode.
Standard communication
features
Technical data
Sn [kVA]
Pn [kW]
Input / output
Parallel configuration
INPUT
Rated voltage
Voltage tolerance
Rated frequency
Frequency tolerance
Power factor / THDI
OUTPUT
Rated voltage
Voltage tolerance static load
Rated frequency
Frequency tolerance
Total output voltage distortion
linear load
Total output voltage distortion
non-linear load (lEC 62043-3)
Short-circuit current
Overload
Crest factor
BYPASS
Rated voltage
Voltage tolerance
Rated frequency
Frequency tolerance
EFFICIENCY
Online mode @ 40 % of load
Online mode @ 75 % of load
Online mode @ 100 % of load
Fast EcoMode
ENVIRONMENT
Operating ambient temperature
Relative humidity
Maximum altitude
Acoustic level at 1 m (ISO 3746)
UPS CABINET
W
Dimensions
D
H
Weight
Degree of protection
Colours
STANDARDS
Safety
EMC
Performance
Product declaration
160
160
DELPHYS GP
250
320
250
320
3/3
up to 4 MW
200
200
400
400
500
500
400 V 3ph
200 V to 480 V (1)
50/60 Hz
± 10 Hz
> 0.99 / < 2.5% (2)
• User-friendly multilingual interface with
graphic display.
• 2 slots for communication options.
• RS232 serial port for modem.
• Ethernet connection (WEB/SNMP/MODBUS
TCP/email).
• USB port for event log access.
Communication options
• Advanced server shutdown options for
stand-alone and virtual servers.
• 4 additional slots for communication options.
• ADC interface (configurable voltage-free
contacts).
• MODBUS/JBUS RTU.
• BACnet/IP interface.
• SMS alert.
3ph + N 400 V
±1 % dynamic load in accordance with VFI-SS-111
50/60 Hz
± 2% (configurable for GenSet compatibility)
ThdU < 1.5%
ThdU < 3%
Remote monitoring service
up to 3.4 x In
125% for 10 minutes, 150% for 1 minute (1)
3:1
• Remote mobile and web-based surveillance
service connected 24/7 to your local
Socomec Service Centre.
rated output voltage
± 15% (configurable with from 10% to 20%)
50/60 Hz
± 2% (configurable for GenSet compatibility)
up to 96%
up to 96%
up to 96%
up to 99%
from 10 °C up to +40 (1) °C (from 15 °C to 25 °C for maximum battery life)
0 % - 95 % without condensation
1000 m without derating (max. 3000 m)
< 65 dBA
< 67 dBA
< 70 dBA
< 68 dBA
< 70 dBA
< 72 dBA
700 mm
800 mm
470 kg
490 kg
1000 mm
1400 mm
950 mm
800 mm
1930 mm
850 kg
980 kg
1000 kg
IP20 (other IP as option)
cabinet: RAL 7012, door: silver grey
1600 mm
950 mm
1500 kg
EN 62040-1, EN 60950-1
EN 62040-2
EN 62040-3 (VFI-SS-111)
CE
(1) Conditions apply. (2) With input THDV < 1%.
Catalogue 2013
15
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement