Untitled - LS-Vina
Aug. 2011
2011 LS Cable & System, Ltd. All right reserved
System List
Structured Cabling System
Shield/Unshield
4pr Cable
Multi-pair Cable
Patch Panel
Modular Jack
Patch Cord
110 Block
Face Plate
Indoor FO Cable
ODF
Fiber Jumper Cord
Fiber Fl Connector
Rack
Multiplexer
Intelligent System
In-Building RF Solution
Yagi Antenna
Patch Antenna
Omni Antenna
Tapper
Splitter
Combiner
Repeater
RF Feeder Cable
RF Radiating Cable
RF Connector
RF Jumper Cord
Product List
Total System Integration
SI
Integrated
Management
Center
Situational
Control
FMS
Facilities
Management
BA(Building Automation)
Facility
Facilities Control
Power
Power Control
CCTV
Emergency Alarm
Parking
Entry
Entry Management Parking
TC(Telecommunication)
Cabling
Cabling
Management
Audio
Broadcasting
Management
OA(Office Automation)
Guide
Building
Information
Station
Content Creation
Light
Light Control
Management
Pos LAN
Non-stop Service
Structured Cabling System
Business should be simple, so keep it Simple with LS
Every organization around the world requires a reliable and fast IT network.
Providing world-class performance, allowing them to stay ahead of their competitors
and growing their business. Over the past two decades we have made massive
advancements in technology, pushing the industries knowledge to the limit, giving
our clients the best solutions for today and meeting tomorrow s requirements.
As the industry standard committees have developed and defined structured cabling
standards, it has become even more important for end users to understand what
solution best supports their requirements. Their networks are now required to carry
traditional data at faster speeds and increasing volumes, voice using VoIP and video
as well as information from building management systems. IP has become the
language of the world, and is being used in more and more applications.
Having this vast array of information travelling across your network by wireless,
optical or copper mediums can be extremely confusing for end users. Knowing
exactly what to use and where, will maximize the return on your budget expenditure.
LS Cable & System has developed a range of solutions to make it simple for end
users to know what they need and where they need it to meet their requirements. LS
SimpleTM provides a key platform for all involved in an IT network, from the end user,
through to the system integrator and distributor. LS Cable & System has simplified
the decision making process, on which IT network best meets your needs. This
network is fully supported by a comprehensive warranty giving complete peace on
mind for 25 years. This coupled with LS Cable & System s strict LS approved SI
program, means the end users can be assured of receiving industry-leading
networks anywhere in the world.
LS Cable & System has now simplified the decision of which structured cabling
solution you require, giving our clients world class networks, with world-class support
- SimpleTM.
Making it easier for our existing and potential clients to choose the right system for
their requirements has never been more Simple.
LS Make It Simple
SimpleTM solutions in copper and fiber
Supported by SimpleTM product designs
Manufactured to the SimpleTM highest level of quality
SimpleTM comprehensive warranty
SimpleTM approved SI s
SimpleTM distribution partners
Contents
SimpleTM Voice & Telephone
SimpleTM Category 6A Solutions
09
Category 6A Channel
50
Category 3 U/UTP Cable 25 ~ 500 Pair
10
Category 6A U/UTP Cable 4 Pair
51
Unshielded Voice Patch Panel
11
Category 6A F/UTP Cable 4 Pair
12
Category 6A Patch Panel
13
Category 6A Modular Jack
14
Category 6A Patch Cord
15
Third Party Accreditation (Category 6A)
86
Intelligent Power Management Solutions
90
Monitoring Unit
53
Faceplate
92
Intelligent Power Distribution Unit (i-PDU)
54
Empty Patch Panel / Faceplate / Back Box
94
Remote Monitoring Link Box
55
Adaptor Insert
95
Sensors
56
Surface Mount Box / Modular Plug
97
Intelligent Power Management Software
SimpleTM Fiber Solutions
99
CL-Amp Kit Solution
17
TM
Solutions
SimpleTM Outlet
SimpleTM Category 6+ Solutions
Category 6+ U/UTP Cable 4 Pair
18 Category 6+ Unshielded Patch Panel
19 Category 6+ Modular Jack
SimpleTM Intelligent Power Management
Simple ViewTM Intelligent Cabling
Management Solutions
Indoor Fiber Optic Cables
58
All Dielectric Single Jacketed Central Tube
59
900um 2fiber buffered Aramid yarn strength member
104
Intelligent Cabling Management Solutions
Simple ViewTM Hardware
Simple Category 6 Solutions
60
900um tight buffered Glass yarn strength member
106
21
Category 6 Channel
61
900um tight buffered Aramid yarn strength member
109
Simple ViewTM Copper Patch Panel
22
Category 6 U/UTP Cable 4 Pair
62
ONFR(riser rated), OFNP(plenum rated) or LSZH rated
112
Simple ViewTM Fiber Optic Patch Panel
23
Category 6 F/UTP Cable 4 Pair
63
Micro Distribution Cable
113
Simple ViewTM Fiber MPO Patch Panel
24
Category 6 SF/UTP Cable 4 Pair
Outdoor Fiber Optic Cables
115
Simple ViewTM Patch Cord (Copper & Fiber)
25
Category 6 Unshielded Patch Panel
64
All Dielectric Single Jacket Non-Armor Loose Tube Cable
116
Simple ViewTM Accessories
26
Category 6 Shielded Patch Panel
65
117
Simple ViewTM Management Software
27
Category 6 Feed-Through Patch Panel
All Dielectric Single Jacketed Multi Loose Tube
with Polyamide Sheath for Insect-resistant
118
Simple ViewTM Site Pro
28
Category 6 Modular Jack
29
Category 6 Euro & 6C RJ45 Module
30
Category 6 Patch Cord (Unshielded / Shielded)
31
Category 6 GXC Patching System
32
GXC Patching System / Cat.6 110 Patch Cord
33
Third Party Accreditation (Category 6)
66
Optical Fiber Distribution / Adaptor & Connector
Reference
LS Fiber Distribution Frame with Module Panel & Gland 120 SimpleTM Warranty
122 Installation Manual for the tool-less M/J
68 LS-SC Field Installable Optical Connector
67
69
Installation Manual for Field Installable Optical Connector 123 Products & Systems of LS Cable & System
70
Fiber Optic Jumper Cord & Fiber Optic Pigtail
SimpleTM Multiplexer
SimpleTM Category 5e Solutions
72
FTTx System
73
Switching Hub Series
35
Category 5e Channel
36
Category 5e U/UTP Cable 4 Pair
37
Category 5e U/UTP Cable 25 Pair
38
Category 5e F/UTP Cable 4 Pair
75
ECX Series 75 Coaxial Cable
39
Category 5e SF/UTP Cable 4 Pair
76
RG Series6 Coaxial Cable
40
Category 5e Unshielded Patch Panel
77
RG Series6/11 Coaxial Cable
41
Category 5e Shielded Patch Panel
78
HFBT Series Coaxial Cable
42
Category 5e UTP Mini Patch Panel
43
Category 5e Modular Jack
44
Category 5e Euro & 6C RJ45 Module
45
Category 5e Patch Cord (Unshielded / Shielded)
46
Category 5e 110 Block / Connecting Block
47
110 Patch Cord / Jumper Trough
48
Third Party Accreditation (Category 5e)
SimpleTM CATV Cable
SimpleTM Rack & Cable Management
80
Cabinet Rack
81
Open Rack
82
Rack Accessory
83
Overhead routing system
124 Global Network
SimpleTM Category 6A Solutions
Category 6A Channel
Category 6A U/UTP Cable 4 Pair
Category 6A F/UTP Cable 4 Pair
Category 6A Patch Panel
Category 6A Modular Jack
Category 6A Patch Cord
Third Party Accreditation (Category 6A)
Category 6A Channel
Cat.6A
Equipment Cord
Cat.6A
Patch Cord
Cat.6A
UTP Cable
Cat.6A
Patch Cord
SimpleTM Cat. 6A Solutions
Diagram
C6A
Switching Hub
C6A
Cat.6A Modular Patch Panel
Cat.6A
Modular Jack
Channel
Guaranteed Channel Performances
Frequency
Attenuation
(MHz)
NEXT
PSNEXT
ELFEXT
PSELFEXT
Return
Loss
PSANEXT
PSAELFEXT
(dB / 100m)
(dB)
(dB)
(dB / 100m)
(dB / 100m)
(dB)
(dB / 100m)
(dB / 100m)
1.00
2.3
65.0
62.0
63.3
60.3
19.0
82.0 *
77.9 *
4.00
4.2
63.0
60.5
51.2
48.2
19.0
76.0 *
65.9
8.00
5.9
58.2
55.6
45.2
42.2
19.0
73.0 *
59.8
10.00
6.6
56.6
54.0
43.3
40.3
19.0
72.0 *
57.9
16.00
8.3
53.2
50.6
39.2
36.2
18.0
70.0 *
53.8
20.00
9.3
51.6
49.0
37.2
34.2
17.5
69.0 *
51.9
25.00
10.5
50.0
47.3
35.3
32.3
17.0
68.0 *
49.9
31.25
11.7
48.4
45.7
33.4
30.4
16.5
67.1 *
48.0
62.50
16.9
43.4
40.6
27.3
24.3
14.0
64.0
42.0
100.00
21.7
39.9
37.1
23.3
20.3
12.0
62.0
37.9
200.00
31.7
34.8
31.9
17.2
14.2
9.0
57.5
31.9
250.00
35.9
33.1
30.2
15.3
12.3
8.0
56.0
29.9
300.00
39.8
31.7
28.8
13.7
10.7
7.2
54.8
28.4
400.00
46.9
26.8
23.8
11.2
8.2
6.0
53.0
25.9
500.00
53.4
22.0
19.0
9.3
6.3
6.0
51.5
23.9
* The figures larger than 67dB for PSANEXT and PSAELFEXT are information only.
Typical Channel Performance
Attenuation
NEXT
PSNEXT
ELFEXT
PSELFEXT
Return
Loss
PSANEXT
PSAELFEXT
(dB / 100m)
(dB)
(dB)
(dB)
(dB)
(dB)
(dB / 100m)
(dB / 100m)
-10%
+8
+8
+10
+10
+8
+8
+10
9
SimpleTM Cat. 6A Solutions
Category 6A U/UTP Cable 4 Pair
Conductor
Jacket (PVC/LSZH)
Insulation (HDPE/FEP)
Cross Filler
Rip Cord (Optional)
Twisted Pair
Patent Pending
Application
Description
ETL Channel certification
Horizontal Distribution & Backbone Cabling
Capable of handling full broadband and baseband video signals
4/16 Mbps Token Ring (IEEE 802.5)
High flame retardant grade of the cable is protected propagation of fire (Plenum Cable)
10/100/1000/10G BASE-T (IEEE 802.3)
Addition of balance requirements improves cable performance
155 Mbps ATM
Electrical performances comply with TIA/EIA-568B.2-10
100Mbps TP-PMD
Specialized print legend contains footage marking from 1000 to 0 , metric from 305 to 0m and
ISDN, ADSL
dual marking footage and metric
ATM LAN 1.2G
Wooden Reel is standard, so wire pulls through reel for easy access
Alien Crosstalk and RoHS compliant
Part Numbers
Category 6A UTP Cable, 4-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
CMP
LSZH
UTP-A-C6G-E1VI-X
0.5 X 004P/(1)
UTP-A-C6G-E1VI-M
0.5X004P/(1)
UTP-A-C6G-E1VI-R
0.5X004P/(1)
UTP-A-C6G-F1VI-P
0.5X004P/(1)
UTP-A-C6G-E1ZI-X
0.5X004P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Unit
PVC / LSZH
Plenum
Ohms/100 m
9.38
9.38
%
5
5
Mutual Capacitance
nF/100 m
5.6
5.6
Capacitance Unbalance
pF/100 m
Characteristic Impedance
Ohms
Resistance Unbalance
15%
100
15%
ns/100 m
536 @ 500MHz
536 @ 500 MHz
Delay Skew
ns
45
45
Nominal Velocity of Propagation
%
67
69
Operating Temperature
/
-20 ~ 60 / -4 ~ 140
-20 ~ 60 / -4 ~140
Storage Temperature
/
Propagation Delay
Bending Radius
Packaging Type
Packaging Weight
-20 ~ 80 / -4 ~ 176
-20 ~ 80 / -4 ~ 176
4 x Cable Diameter
4 x Cable Diameter
305 m (1000ft)
Reel
Reel
lb/kft (kg/km)
37 (55)
43 (65)
23 AWG, Solid Copper
Conductor Diameter / Material
10
330
330
100
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
0.041 (1.05)
23 AWG, Solid Copper
, HDPE
0.3543 (9.0) , PVC or LSZH (Low Smoke Zero Halogen)
0.041 (1.05)
0.3543 (9.0)
, FEP
, PVC (Plenum Rated)
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / CMP - UL910 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2-10 / ISO 11801 Performance specifications for 100 Ohm Category 6A / EA Cabling
SimpleTM Cat. 6A Solutions
Category 6A F/UTP Cable 4 Pair
Conductor
Jacket (PVC/LSZH)
Insulation (HDPE)
Cross Filler
Drain Wire
A/Mylar Tape
Twisted Pair
Polyester Tape (Optional)
Application
Description
ETL Channel and UL Cable certification
Horizontal Distribution & Backbone Cabling
Capable of handling full broadband and baseband video signals
4/16 Mbps Token Ring (IEEE 802.5)
High flame retardant grade of the cable is protected propagation of fire
10/100/1000/10G BASE-T (IEEE 802.3)
Addition of balance requirements improves cable performance
155 Mbps ATM
Electrical performances comply with TIA/EIA-568B.2-10
100Mbps TP-PMD
Specialized print legend contains footage marking from 1000 ‘to 0’, metric from 305 to 0m and
ISDN, ADSL
“DUAL MARKING” footage and metric
ATM LAN 1.2G
Wooden Reel is standard, so wire pulls through reel for easy access
RoHS Compliant
Part Numbers
Category 6A FTP Cable, 4-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
LSZH
FTP-A-C6G-E1VN-X
0.5X004P/(1)
FTP-A-C6G-E1VN-M
0.5X004P/(1)
FTP-A-C6G-E1VN-R
0.5X004P/(1)
FTP-A-C6G-E1ZN-X
0.5X004P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Unit
PVC / LSZH
Ohms/100 m
9.38
%
5
Mutual Capacitance
nF/100 m
5.6
Capacitance Unbalance
pF/100 m
Characteristic Impedance
Ohms
Resistance Unbalance
330
15%
100
ns/100 m
536 @ 500MHz
Delay Skew
ns
45
Nominal Velocity of Propagation
%
Propagation Delay
-20 ~ 80
Storage Temperature
4 x Cable Diameter
Bending Radius
Packaging Type
Packaging Weight
67
-20 ~ 60
Operating Temperature
305 m (1000ft)
Reel
lb/kft (kg/km)
43 (65)
23 AWG, Solid Copper
Conductor Diameter / Material
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
0.045 (1.15)
, HDPE
0.307 (7.8) , PVC or LSZH (Low Smoke Zero Halogen)
Safety Standard, Performance Standard
CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2-10 / ISO 11801 Performance specifications for 100 Ohm Category 6A Cabling
11
SimpleTM Cat. 6A Solutions
Category 6A Patch Panel
Description
This PCB 1U patch panel comes complete with cable management, accessories and full installation
instructions. It fully complies with the requirements set out in ANSI/TIA/EIA-568-B.2-10.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000/10G BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
ATM LAN 1.2G
Part Numbers
Description
Dimension (H x W)
Part Number
24-Port Category 6A Unshielded Patch Panel of slim IDC with Wire Management
1.75 x 19 (1U)
LS-PP-UC6A-24P-WM-SI
24-Port Category 6A Shielded Patch Panel with Wire Management
1.75 x 19 (1U)
LS-PP-SC6A-24P-WM
Technical Details
Electrical / Mechanical Characteristics
Insulation Resistance : 500 Megaohm
DC Resistance : 0.1 ohm Max.
UL 94V-0 Rated
Spring Wire : Phosphor Bronze Plated with 30 or
Voltage : 150 Vac Max.
50 Micro-inch (1.27 microns) Thick
Insertion Life : 750 Mating Cycles
Gold Over 100 Micro-inch (2.54
Plug Retention Force : 20 lbs (89N)
microns) Thick Nickel Undercoat
Temperature : -40 ~68
(-40 ~154 )
Humidity : 10%~90%RH
IDC Accept : 22~26 AWG Solid Wire
IDC Plastic : Polycarbonate, UL 94V-0 Rated
IDC Contact : Phosphor Bronze Plated with100
Micro-inch (2.54 microns) Minimum
Thick Tin
Approvals
Category : TIA/EIA-568-B.2-10
Category 6A / ISO 11801 Category EA
Meet : FCC CFR 47 Parts 68
Wiring Scheme : T568A/T568B
12
Materials
Housing : High Impact Flame Retardant Plastic,
Current Rating : 1.5 Amps
Panel : Steel with Black Painting
Category 6A Modular Jack
SimpleTM Cat. 6A Solutions
Description
LS SimpleTM Category 6A modular jacks are designed and manufactured to meet today s and tomorrow s
demanding international standards. They take into consideration the need for reliable and quick installations.
The Jack is individually terminated using Insulation Displacement Connectors (IDC) giving assurance of wire
connection when using a punch down tool and handing tool for easy installation.
User instructions and basic wiring layout for standard configuration are included.
The LS SimpleTM Modular Jack comes with the ability to wire to a T568A or T568B configuration and fully
complies with TIA/EIA-568-B.2-10-Augmented Category 6 transmission Performance.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000/10G BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
ATM LAN 1.2G
Part Numbers
Part Number
Description
90 Category 6A Unshielded Modular Jack of Slim IDC with T568A/B Label
LS-MJ-UC6A-XX-SI
90 Category 6A Shielded Modular Jack with T568A/B Label, Tool Less
LS-MJ-SC6A-XX-TL
180 Category 6A Shielded Modular Jack of RIDC with T568A/B Label, Tool less
LS-MJ-SC6A-XX-TL-RIDC
* XX Denotes Color : WH=White, BL=Blue * Fit with Empty Patch Panel
Technical Details
Electrical / Mechanical Characteristics
Materials
Housing : High Impact Flame Retardant Plastic,
Current Rating : 1.5 Amps
Insulation Resistance : 500 Megaohm
UL 94V-0 Rated
Spring Wire : Phosphor Bronze Plated with 50
DC Resistance : 0.1 ohm Max.
Voltage :150 VAC Max.
Micro-inch (1.27 microns) Thick Gold
Insertion Life : 750 Mating Cycles
Over 100 Micro-inch (2.54 microns)
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~ 154 )
Humidity : 10% ~ 90%RH
IDC Accept : 22~26 AWG Solid Wire
Thick Nickel Undercoat
IDC Plastic : Polycarbonate, UL 94V-0 Rated
IDC Contact : Phosphor Bronze Plated with100
Micro-inch (2.54 microns) Minimum
Thick Tin
Approvals
Category : TIA/EIA-568-B.2-10
Category 6A / ISO 11801 Category EA
Meet : FCC CFR 47 Parts 68
Wiring Scheme : T568A/T568B
13
Category 6A Patch Cord
SimpleTM Cat. 6A Solutions
Description
LS SimpleTM Category 6A patch cords are factory terminated, providing the quality required to support your
channel requirements. They are fully booted and have clip protection for simple removal. They offer a high
performance alternative to satin modular line cords where crosstalk, EMI, or distance may be considerations.
Cable consists of 24 AWG (0.51mm) wire, each four pair twisted at a different lay length.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000/10G BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
ATM LAN 1.2G
Part Numbers
Part Number
Description
Unshielded Category 6A Patch Cord with T568B Wiring
LS-PC-UC6AX-YY-ZZZ
Shielded Category 6A Patch Cord with T568B Wiring
LS-PC-SC6AX-YY-ZZZ
X denotes jacket material : V=PVC, Z=LSZH
YY denotes color : WH=White, BL=Blue, YL=Yellow, RD=Red, GN=Green, GY=Grey
ZZZ denotes meter : 005(0.5m), 010(1m), 050(5m), etc
Technical Details
Electrical / Mechanical Characteristics
Plug Housing : Polycarbonate (PC), UL 94V-2 Rated
Insulation Resistance : 500 Megohm Min.
Contact Blade : Phosphor Bronze Plated with 50
Contact Resistance : 20 Milli-ohm Max.
Micro-inch (1.27 microns) Thick
Dielectric Strength : 1000 VAC (RMS)
Gold Over 100 Micro-inch (2.54
microns) Thick Nickel Undercoat
Voltage : 30 VAC Max.
Cable Jacket : PVC, LSZH
Insertion Life : 750 Mating Cycles
Plug Retention Force : 20 lbs (89N)
Temperature : -20
~ 68
(-4
~ 154 )
Humidity : 10% ~ 90%RH
Contact Accept : 24~26 AWG Standard Wire
Approvals
Category : TIA/EIA-568-B.2-10
Category 6A / ISO 11801 Category EA
Meet : FCC CFR 47 Part 68 and IEC 603-7
Wiring Scheme : T568B
14
Materials
Current Rating : 1.5 Amps
SimpleTM Cat. 6A Solutions
Third Party Accreditation (Category 6A)
15
SimpleTM Category 6+ Solutions
Category 6+ U/UTP Cable 4 Pair
Category 6+ Unshielded Patch Panel
Category 6+ Modular Jack
Guaranteed Channel Performance
The additional +3dB margin of NEXT, ELFEXT in channel performance (compared to standard Cat6 level) is
guaranteed by the enhancement of cable and jack, even using standard Cat6 patch cord application.
Supporting stabilization of communication environment, this solution is suited to high profile application for
data center and bank.
Category 6+ U/UTP Cable 4 Pair
Conductor
SimpleTM Cat. 6+ Solutions
Jacket (PVC/LSZH)
Rip Cord (Optional)
Cross filler
Twisted Pair
Insulation (HDPE/FEP)
Description
Application
ETL, EC Verified, UL Listed
Capable of handling full broadband and baseband video signals
High flame retardant grade of the cable is protected propagation of fire
Addition of Near End Crosstalk requirements improves cable performance
Electrical performances comply with TIA/EIA-568B.2-1
Specialized print legend contains footage marking from 1000 to 0 , metric from 305 to 0m and
“Dual Marking” footage and metric
Reel in a box is standard, so wire pulls through box opening for easy access
RoHS Compliant
The Crosstalk performance is specified 3dB higher than standard Category 6 cable
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
ATM LAN 1.2G
Part Numbers
Category 6+ UTP Cable, 4-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
LSZH
UTP-G-C6E-E1VN-X
0.5X004P/(1)
UTP-G-C6E-E1VN-M
0.5X004P/(1)
UTP-G-C6E-E1VN-R
0.5X004P/(1)
UTP-G-C6E-E1ZN-X
0.5X004P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Unit
PVC & LSZH
Ohms/100 m
9.38
%
5
Mutual Capacitance
nF/100 m
5.6
Capacitance Unbalance
pF/100 m
Characteristic Impedance
Ohms
Resistance Unbalance
330
15%
100
ns/100 m
536 @ 250MHz
Delay Skew
ns
45
Nominal Velocity of Propagation
%
67
Operating Temperature
/
-20 ~ 60
Storage Temperature
/
Propagation Delay
-20 ~ 80
4 x Cable Diameter
Bending Radius
Packaging Type
Packaging Weight
305 m (1000ft)
Reel in a box
lb/kft (kg/km)
23 (35)
24 AWG, Solid Copper
Conductor Diameter / Material
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
0.037 (0.95)
0.244 (6.2)
, HDPE
, PVC or LSZH(Low Smoke Zero Halogen)
Safety Standard, Performance Standard
CMX - UL1581, IEC332-1/ CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2-1 / ISO 11801 Performance specifications for 100 Ohm Category 6 Cabling
17
SimpleTM Cat. 6+ Solutions
Category 6+ Unshielded Patch Panel
Description
This PCB 1U 24 way patch panel comes complete with cable management, accessories and full installation
instructions. They fully comply with the requirements set out in ANSI/TIA/EIA-568-B.2-1.
Application
Horizontal Distribution & Backbone Cabling
100Mbps TP-PMD
4/16 Mbps Token Ring (IEEE 802.5)
ISDN, ADSL
10/100/1000 BASE-T (IEEE 802.3)
RoHS Compliant
155 Mbps ATM
ATM LAN 1.2G
Part Numbers
Description
Dimension (H x W)
Part Number
24-Port Category 6 Unshielded Patch Panel
1.75 x 19 (1U)
of Slim IDC with Wire Management
LS-PP-UC6-24P-WM-SI
Technical Details
Electrical / Mechanical Characteristics
Housing : High Impact Flame Retardant Plastic, UL
Current Rating : 1.5 Amps
Insulation Resistance : 500 Megaohm
94V-0 Rated
Spring Wire : Phosphor Bronze Plated with 50 Micro-
DC Resistance : 0.1 ohm Max.
Voltage : 150 Vac Max.
inch (1.27 microns) Thick Gold Over 100
Insertion Life : 750 Mating Cycles
Micro-inch (2.54 microns) Thick Nickel
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~ 154 )
Humidity : 10% ~ 90% RH
IDC Accept : 22 ~ 26 AWG Solid Wire
Approvals
Category : UL Listed, TIA/EIA-568-B.2-1 / ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A/T568B
Korean Ministry of Information and Communication
Approved
18
Materials
Undercoat
IDC Plastic : Polycarbonate, UL 94V-0 Rated
IDC Contact : Phosphor Bronze Plated with 100 Microinch (2.54 microns) Minimum Thick Tin
Panel : Steel with Black Painting
Category 6+ Modular Jack
Description
Category 6+ Unshielded Modular Jack with slim IDC, The LS SimpleTM Category 6+ Modular Jack are
SimpleTM Cat. 6+ Solutions
90
designed and manufactured to meet today’s and tomorrow’s demanding international standards. They take
into consideration the need for reliable and quick installations. The Jack is individually terminated using
Insulation Displacement Connectors(IDC) giving assurance of wire connection when using a punch down tool.
User instructions and basic wiring layout for standard configuration are included.
The LS SimpleTM Modular Jack comes with the ability to wire to a T568A or T568B configuration and fully
complies with RJ-45 of 47 CFR part 68, TIA/EIA 568-B.2-1(Category 6) and ISO/IEC 11801(Class E)
component performance.
Application
Application
Horizontal Distribution & Backbone Cabling
ISDN, ADSL
4/16 Mbps Token Ring (IEEE 802.5)
Analog & digital voice(VOIP) and video
10/100/1000/10G BASE-T (IEEE 802.3)
Full broadband and baseband video
155 Mbps ATM
RoHS Compliant
100Mbps TP-PMD
ATM LAN 1.2G
Part Numbers
Part Numbers
Description
90
Category 6 Unshielded Modular Jack of slim IDC
LS-MJ-UC6-XX-SI
*Fit with Empty Patch Panel
Technical Details
Electrical / Mechanical Characteristics
Materials
Plug Housing : High Impact Flame Retardant Plastic,
Current Rating : 1.5 Amps
Insulation Resistance : 500 Megohm
UL 94V-0 Rated
Contact Resistance : 0.1 ohm Max.
Spring Wire : Phosphor Bronze Plated with 50
Micro-inch ( 1.27 microns) Thick Gold
Voltage : 150 VAC Max.
Over 100 Micro-inch (2.54 microns)
Insertion Life : 750 Mating Cycles
Plug Retention Force : 20 lbs (89N)
IDC Plastic : Polycarbonate or ABS, UL 94V-0 Rated
Temperature : -40
IDC Contact : Phosphor Bronze Plated with 100
~ 68
(-40
~ 154 )
Humidity : 10% ~ 90%RH
Micro-inch (2.54 microns) Minimum
Contact Accept : 22~26 AWG Standard Wire
Thick Tin
Approvals
Category : UL Listed, TIA/EIA-568-B.2-1 /
ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A / T568B
Korean Ministry of Information and Communication
Approved
19
SimpleTM Category 6 Solutions
Category 6 Channel
Category 6 U/UTP Cable 4 Pair
Category 6 F/UTP Cable 4 Pair
Category 6 SF/UTP Cable 4 Pair
Category 6 Unshielded Patch Panel
Category 6 Shielded Patch Panel
Category 6 Feed-Through Patch Panel
Category 6 Modular Jack
Category 6 Euro & 6C RJ45 Module
Category 6 Patch Cord (Unshielded / Shielded)
Category 6 GXC Patching System
GXC Patching System / Cat.6 110 Patch Cord
Third Party Accreditation (Category 6)
Category 6 Channel
Diagram
Cat.6
Equipment Cord
Cat.6
Patch Cord
Cat.6
Patch Cord
Cat.6
UTP Cable
Cat.6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
SimpleTM Category 6 Solutions
Switching Hub
Cat.6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Cat.6 Patch Panel
Cat.6
Consolidation
Modular Jack
Point
Channel
Guaranteed Channel Performances
Frequency
Attenuation
(MHz)
NEXT
PSNEXT
PSACR
ACR
ELFEXT
PSELFEXT
Return
Loss
(dB / 100m)
(dB)
(dB)
(dB)
(dB)
(dB)
(dB)
(dB)
1.00
2.1
65.0
62.0
62.9
59.9
63.3
60.3
19.0
4.00
4.0
63.0
60.5
59.0
56.5
51.2
48.2
19.0
8.00
5.7
58.2
55.6
52.5
49.9
45.2
42.2
19.0
10.00
6.3
56.6
54.0
50.2
47.7
43.3
40.3
19.0
16.00
8.0
53.2
50.6
45.2
42.6
39.2
36.2
18.0
20.00
9.0
51.6
49.0
42.6
39.9
37.2
34.2
17.5
25.00
10.1
50.0
47.3
39.9
37.2
35.3
32.3
17.0
31.25
11.4
48.4
45.7
37.0
34.3
33.4
30.4
16.5
62.50
16.5
43.4
40.6
26.9
24.1
27.3
24.3
14.0
100.00
21.3
39.9
37.1
18.6
15.8
23.3
20.3
12.0
200.00
31.5
34.8
31.9
3.3
0.3
17.2
14.2
9.0
250.00
35.9
33.1
30.2
(-)
(-)
15.3
12.3
8.0
Typical Channel Performance
Attenuation
NEXT
PSNEXT
ELFEXT
PSELFEXT
Return
Loss
(dB / 100m)
(dB)
(dB)
(dB)
(dB)
(dB)
-10%
+8
+8
+10
+10
+8
21
Category 6 U/UTP Cable 4 Pair
Conductor
Conductor
Jacket
(PVC/LSZH)
Jacket
(PVC/LSZH)
Insulation
(HDPE/FEP)
Insulation
(HDPE/FEP)
Cross Filler
Rip Cord
(Optional)
Rip Cord
(Optional)
Twisted Pair
SimpleTM Category 6 Solutions
Twisted Pair
Description
Application
ETL, EC Verified, UL Listed
Capable of handling full broadband and baseband video signals
High flame retardant grade of the cable is protected propagation of fire (Plenum Cable)
Addition of balance requirements improves cable performance
Electrical performances comply with TIA/EIA-568B.2-1
Specialized print legend contains footage marking from 1000 to 0 , metric from 305 to 0m and
dual marking footage and metric
Reelex & Reel in a box is standard, so wire pulls through box opening for easy access
RoHS Compliant
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
ATM LAN 1.2G
Part Numbers
Category 6 UTP Cable, 4-Pair
Description
CMX
CM
CMR
CMP
LSZH
Part Numbers (Cross Filler)
UTP-G-C6G-E1VN-X
0.5X004P/(1)
UTP-G-C6G-E1VN-M
0.5X004P/(1)
UTP-G-C6G-E1VN-R
0.5X004P/(1)
UTP-G-C6G-F1VN-P
0.5X004P/(1)
UTP-G-C6G-E1ZN-X
0.5X004P/(1)
Part Numbers (Non Filler)
UTP-G-C6G-E1VX-X
0.5X004P/(1)
UTP-G-C6G-E1VX-M
0.5X004P/(1)
UTP-G-C6G-E1VX-R
0.5X004P/(1)
UTP-G-C6G-F1VX-P
0.5X004P/(1)
UTP-G-C6G-E1ZX-X
0.5X004P/(1)
Flame Retardant Grade
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Resistance Unbalance
Unit
PVC & LSZH / Plenum (Cross Filler)
PVC & LSZH / Plenum (Non Filler)
Ohms/100 m
9.38
9.38
%
5
5
Mutual Capacitance
nF/100 m
5.6
5.6
Capacitance Unbalance
pF/100 m
330
330
Characteristic Impedance
Ohms
15%
100
15%
536 @ 250MHz
536 @ 250 MHz
Delay Skew
ns
45
45
Nominal Velocity of Propagation
%
67 / 69
67 / 69
Operating Temperature
/
-20 ~ 60 / -4 ~ 140
-20 ~ 60 / -4 ~ 140
Storage Temperature
/
Bending Radius
Packaging Type
Packaging Weight
305 m (1000ft)
lb/kft (kg/km)
Conductor Diameter / Material
22
100
ns/100 m
Propagation Delay
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
-20 ~ 80 / -4 ~ 176
-20 ~ 80 / -4 ~ 176
4 x Cable Diameter
4 x Cable Diameter
Reelex / Reel in a box
Reelex / Reel in a box
21 (32) / 27 (42)
19 (29) / 25 (38)
24 AWG, Solid Copper
24 AWG, Solid Copper
0.037 (0.95)
, HDPE / FEP
0.228 (5.8) / 0.220(5.6) , PVC or LSZH
0.037 (0.95)
, HDPE / FEP
0.205 (5.2) / 0.200(5.1) , PVC or LSZH
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1/ CM - UL1685, IEC332-3 / CMR - UL1666 / CMP - UL910 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2-1 / ISO 11801 Performance specifications for 4-Pairs 100 Ohm Category 6 / E Cabling
Category 6 F/UTP Cable 4 Pair
Conductor
Jacket (PVC/LSZH)
Insulation (HDPE)
Cross Filler
Drain Wire
A/Mylar Tape
SimpleTM Category 6 Solutions
Twisted Pair
Polyester Tape (Optional)
Description
Application
Capable of handling full broadband and baseband video signals
Horizontal Distribution & Backbone Cabling
Addition of balance requirements improves cable performance
4/16 Mbps Token Ring (IEEE 802.5)
Electrical performances comply with TIA/EIA-568B.2-1
10/100/1000 BASE-T (IEEE 802.3)
Specialized print legend contains footage marking from 1000 to 0, metric from 305 to 0m and
155 Mbps ATM
dual marking footage and metric
100Mbps TP-PMD
Wooden reel is standard, so wire pulls through reel for easy access
ISDN, ADSL
RoHS Compliant
ATM LAN 1.2G
Part Numbers
Category 6 FTP Cable, 4-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
LSZH
FTP-G-C6G-E1VN-X
0.5X004P/(1)
FTP-G-C6G-E1VN-M
0.5X004P/(1)
FTP-G-C6G-E1VN-R
0.5X004P/(1)
FTP-G-C6G-E1ZN-X
0.5X004P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Resistance Unbalance
Unit
PVC / LSZH
Ohms/100 m
9.38
%
5
Mutual Capacitance
nF/100 m
5.6
Capacitance Unbalance
pF/100 m
330
Characteristic Impedance
15%
100
Ohms
ns/100 m
536 @ 250MHz
Delay Skew
ns
45
Nominal Velocity of Propagation
%
67
Operating Temperature
/
-20 ~ 60 / -4 ~ 140
Storage Temperature
/
Propagation Delay
-20 ~ 80 / -4 ~ 176
4 x Cable Diameter
Bending Radius
Packaging Type
Packaging Weight
305 m (1000 ft) / 500 m
Reel
lb/kft (kg/km)
36 (54)
23 AWG, Solid Copper
Conductor Diameter / Material
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
0.043 (1.10)
0.287 (7.3)
, HDPE
, PVC or LSZH (Low Smoke Zero Halogen)
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2-1 / ISO 11801 Performance specifications for 4-Pairs 100 Ohm Category 6 / E Cabling
23
Category 6 SF/UTP Cable 4 Pair
Conductor
Jacket (PVC/LSZH)
Insulation (HDPE/FEP)
Cross Filler
AI/Mylar Tape
PS Tape
SimpleTM Category 6 Solutions
Twisted Pair
Tinned Copper Braid
Description
Application
•Capable of handling full broadband and baseband video signals
•Horizontal Distribution & Backbone Cabling
•Addition of balance requirements improves cable performance
•4/16 Mbps Token Ring (IEEE 802.5)
•Every master reel is tested for electrical performance compliance.
•10/100/1000 BASE-T (IEEE 802.3)
•Specialized print legend contains footage marking from 1000 ‘to 0’, metric from 305 to 0m and
•155 Mbps ATM
•100Mbps TP-PMD
dual marking footage and metric
•Wooden Reel is standard, so wire pulls through reel for easy access
•ISDN, ADSL
•RoHS Compliant
Part Numbers
Category 6 FTP Cable, 4-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
LSZH
SFP-G-C6G-E1VN-X
0.5X004P/(1)
SFP-G-C6G-E1VN-M
0.5X004P/(1)
SFP-G-C6G-E1VN-R
0.5X004P/(1)
SFP-G-C6G-E1ZN-X
0.5X004P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Unit
PVC / LSZH
Ohms/100 m
9.38
%
5
Mutual Capacitance
nF/100 m
5.6
Capacitance Unbalance
pF/100 m
330
Resistance Unbalance
Ohms
100 ±15%
ns/100 m
536 @ 250MHz
Delay Skew
ns
45
Nominal Velocity of Propagation
%
Characteristic Impedance
Propagation Delay
67
-20 ~ 60 / -4 ~ 140
Operating Temperature
Storage Temperature
-20 ~ 80 / -4 ~ 176
Bending Radius
4 x Cable Diameter
Packaging Type
Packaging Weight
300 m / 500 m
Wooden Reel
lb/kft (kg/km)
45 (68)
23 AWG, Solid Copper
Conductor Diameter / Material
24
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
0.044 (1.12)
0.311 (7.9)
, HDPE
, PVC or LSZH (Low Smoke Zero Halogen)
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2-1 / ISO 11801“Performance specifications for 4-Pairs 100 Ohm Category 6 / E Cabling”
SimpleTM Category 6 Solutions
Category 6 Unshielded Patch Panel
Description
These PCB 1U 24 way patch panel and 2U 48 way patch panel come complete with cable management,
accessories and full installation instructions. They fully comply with the requirements set out in ANSI/TIA/EIA568-B.2-1.
Application
Horizontal Distribution & Backbone Cabling
100Mbps TP-PMD
4/16 Mbps Token Ring (IEEE 802.5)
ISDN, ADSL
10/100/1000 BASE-T (IEEE 802.3)
RoHS Compliant
155 Mbps ATM
ATM LAN 1.2G
Part Numbers
Dimension (H x W)
Part Number
90° 24-Port Category 6 Unshielded Patch Panel with Wire Management
1.75 x 19 (1U)
LS-PP-UC6-24P-WH
90° 24-Port Category 6 Unshielded Patch Panel with Horizontal PCB
1.75 x 19 (1U)
LS-PP-UC6-24PH-WH
Description
90° 48-Port Category 6 Unshielded Patch Panel with Wire Management
3.50 x 19 (2U)
LS-PP-UC6-48P-WH
180° 24-Port Category 6 Unshielded Patch Panel of RIDC with Wire Management
1.75 x 19 (1U)
LS-PP-UC6-24P-WH-RI
180° 48-Port Category 6 Unshielded Patch Panel of RIDC with Wire Management
3.50 x 19 (2U)
LS-PP-UC6-48P-WH-RI
Technical Details
Electrical / Mechanical Characteristics
Materials
Housing : High Impact Flame Retardant Plastic, UL
Current Rating : 1.5 Amps
Insulation Resistance : 500 Megaohm
94V-0 Rated
Spring Wire : Phosphor Bronze Plated with 50 Micro-
DC Resistance : 0.1 ohm Max.
Voltage : 150 Vac Max.
inch (1.27 microns) Thick Gold Over 100
Insertion Life : 750 Mating Cycles
Micro-inch (2.54 microns) Thick Nickel
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~ 154 )
Humidity : 10% ~ 90% RH
IDC Accept : 22 ~ 26 AWG Solid Wire
Approvals
Undercoat
IDC Plastic : Polycarbonate, UL 94V-0 Rated
IDC Contact : Phosphor Bronze Plated with 100 Microinch (2.54 microns) Minimum Thick Tin
Panel : Steel with Black Painting
Category : UL Listed, TIA/EIA-568-B.2-1 / ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A/T568B
Korean Ministry of Information and Communication
Approved
25
SimpleTM Category 6 Solutions
Category 6 Shielded Patch Panel
Description
This PCB 1U 24 way patch panel comes complete with cable management, accessories and full installation
instructions. They fully comply with the requirements set out in ANSI/TIA/EIA-568-B.2-1.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
ATM LAN 1.2G
Part Numbers
Description
Dimension (H x W)
Part Number
1.75 x 19 (1U)
LS-PP-SC6-24P-WM
24-Port Category 6 Shielded Patch Panel
with Wire Management
Technical Details
Electrical / Mechanical Characteristics
Current Rating : 1.5 Amps
Housing : ABS, UL 94V-0 Rated
Insulation Resistance : 500 Megaohm
Jack Spring Wire : Phosphor Bronze with 50 Micro-
DC Resistance : 0.1 ohm Max.
inch (1.27 microns) Thick Gold Over
Dielectric Withstanding Voltage : 1000 V
80 Micro-inch (2.03 microns) Thick
Data Transmission Rates : 100 Mbps
Plug Retention Force : 30 lbs (133N)
Temperature : -20
~ 50
(-4
~ 122 )
Humidity : 10% ~ 90%RH
IDC Accept : 22~26 AWG Solid Wire
Approvals
Category : UL Listed, TIA/EIA-568-B.2-1 / ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A/T568B
Nickel Undercoat
IDC Plastic : PC or ABS, UL 94V-0 Rated
Plug Insertion Life : 750 Cycles
26
Materials
IDC Contact : Phosphor Bronze with 100 Micro- inch
(2.54 microns) Minimum Thick Tin
Panel : Powder Coated Steel with Gray Color
Description
frames suitable for unshielded or shielded coupler,
These PCB 1U 48 way patch panels come complete
double-sided station ID designed for easy
with cable management, accessories and full
identification and ideal for Data center application.
installation instructions. They are compatible for 48-
They fully comply with the requirements set out in
port application in 1 unit height, 12-in-1 modular
TIA/EIA-568-B.2-1.
SimpleTM Category 6 Solutions
Category 6 Feed-Through Patch Panel
Application
Horizontal Distribution & Backbone Cabling
100Mbps TP-PMD
4/16 Mbps Token Ring (IEEE 802.5)
ISDN, ADSL
10/100/1000 BASE-T (IEEE 802.3)
RoHS Compliant
155 Mbps ATM
ATM LAN 1.2G
Part Numbers
Dimension (H x W)
Description
48-Port Category 6 Unshielded Feed-Through
Part Number
1.75 x 19 (1U)
LS-PP-UC6DC-48P-WM
1.75 x 19 (1U)
LS-PP-SC6DC-48P-WM
Patch Panel with Wire Management
48-Port Category 6 Shielded Feed-Through
Patch Panel with Wire Management
* Note : Category 5e patch panels are available
Technical Details
Electrical / Mechanical Characteristics
Materials
Current Rating : 1.5 Amps
Housing : High Impact Flame Retardant Plastic,
Insulation Resistance : 500 Megaohm
UL 94V-0 Rated
DC Resistance : 0.1 ohm Max.
Spring Wire : Phosphor Bronze Plated with 50
Voltage : 150 Vac Max.
Micro-inch (1.27 microns) Thick Gold
Insertion Life : 750 Mating Cycles
Over 100 Micro-inch (2.54 microns)
IDC Plastic : Polycarbonate or ABS, UL 94V-0 Rated
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~ 154 )
IDC Contact : Phosphor Bronze Plated with 100
Humidity : 10% ~ 90% RH
Micro-inch (2.54 microns) Minimum
IDC Accept : 22 ~ 26 AWG Solid Wire
Thick Tin
Approvals
Panel : Steel with Black Painting
Category : UL Listed, TIA/EIA-568-B.2-1 / ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A/T568B
Korean Ministry of Information and Communication
Approved
27
Category 6 Modular Jack
Description
LS SimpleTM Category 6 modular jacks are designed and manufactured to meet today s and tomorrow s
demanding international standards. They take into consideration the need for reliable and quick installations.
The jack is individually terminated using Insulation Displacement Connectors (IDC) giving assurance of wire
connection when using a punch down tool and tool-less for Installation.
User instructions and basic wiring layout for standard configuration are included.
The LS SimpleTM modular jack comes with the ability to wire to a T568A or T568B configuration and fully
SimpleTM Category 6 Solutions
complies with TIA/EIA-568-B.2-1(Category 6) and ISO/IEC 11801(Class E) component performances.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
ATM LAN 1.2G
Part Numbers
Part Number
Description
LS-MJ-UC6-XX
90 Category 6 Unshielded Modular Jack with T568A/B Label
LS-MJ-SC6-XX
90 Category 6 Shielded Modular Jack with T568A/B Label
LS-MJ-UC6-XX-S
90 Category 6 Unshielded Modular Jack with T568A/B Label and Shutter
90 Category 6 Unshielded Modular Jack with T568A/B Label, Tool-Less
LS-MJ-UC6-XX-TL
180 Category 6 Unshielded Modular Jack of RIDC with T568A/B Label
LS-MJ-UC6-XX-RIDC
180 Category 6 Shielded Modular Jack of RIDC with T568A/B Label
LS-MJ-SC6-XX-RIDC
XX denotes color : WH=White, IV=Ivory, BK=Black, BL=Blue, RD=Red
* Note : Shielded modular jack is available in white color only
Technical Details
Electrical / Mechanical Characteristics
Housing : High Impact Flame Retardant Plastic, UL
Current Rating : 1.5 Amps
94V-0 Rated
DC Resistance : 0.1 ohm Max.
Spring Wire : Phosphor Bronze Plated with 50
Voltage : 150 Vac Max.
Insertion Life : 750 Mating Cycles
Micro-inch (1.27 microns) Thick Gold
Plug Retention Force : 20 lbs (89N)
Over 100 Micro-inch (2.54 microns)
Temperature : -40
~ 68
(-40
~ 154 )
IDC Plastic : Polycarbonate or ABS, UL 94V-0 Rated
IDC Accept : 22 ~ 26 AWG Solid Wire
IDC Contact : Phosphor Bronze Plated with100
Category : UL Listed, TIA/EIA-568-B.2-1 / ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A/T568B
Korean Ministry of Information and Communication
Approved
Tool-less type
Thick Nickel Undercoat
Humidity : 10% ~ 90% RH
Approvals
28
Materials
Micro-inch (2.54 microns) Minimum
Thick Tin
Shielded : Copper Zinc Alloy, Pre-Plated with
Bright Nickel
Category 6 Euro & 6C RJ45 Module
Description
The Category 6 compact module is designed to provide a shallow solution for wall outlets. They are the ideal
solution wherever back-box depth is an issue.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
SimpleTM Category 6 Solutions
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
ATM LAN 1.2G
Part Numbers
Description
Dimension (L x W) (mm)
Part Number
50 x 25
LS-MJ-EU-UC6-WH
38.5 X 25
LS-MJ-6C-UC6-WH
Shuttered Low Profile Cat.6 Euro Module
RJ45 (8P8C) T568A/T568B
Shuttered Low Profile Cat6 6C Module
RJ45 (8P8C) T568A/T568B
Technical Details
Electrical / Mechanical Characteristics
Materials
Housing : High Impact Flame Retardant Plastic,
Current Rating : 1.5 Amps
UL 94V-0 Rated
Contact Resistance : 20 Milli-ohm
DC Resistance : 0.1 ohm Max.
Voltage : 150 Vac Max.
Insertion Life : 750 Mating Cycles
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~154 )
Humidity : 10% ~ 90% RH
IDC Accept : 23 ~ 26 AWG Solid Wire
Approvals
Category : UL Listed, TIA/EIA-568-B.2-1 / ISO 11801
Meet : FCC Parts 68
Wiring Scheme : T568A/T568B
29
SimpleTM Category 6 Solutions
Category 6 Patch Cord (Unshielded / Shielded)
Description
LS SimpleTM Category 6 patch cords are factory terminated, providing the quality required to support your
channel requirements. They are fully booted and have clip protection for simple removal. They offer a high
performance alternative to satin modular line cords where crosstalk, EMI, or distance may be considerations.
Cable consists of 24 AWG (0.51mm) wire, each four pair twisted at a different lay length.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100 Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
ATM LAN 1.2G
Part Numbers
Part Number
Description
Category 6 Unshielded Patch Cord with T568B Wiring
LS-PC-UC6-X-YY-ZZZ
Category 6 Shielded Patch Cord with T568B Wiring
LS-PC-SC6-X-YY-ZZZ
X denotes jacket material : V=PVC, Z=LSZH
YY denotes color : WH=White, BL=Blue, YL=Yellow, RD=Red, GN=Green, GY=Grey
ZZZ denotes meter : 005(0.5m), 010(1m), 050(5m), etc
Technical Details
Electrical / Mechanical Characteristics
Housing : Polycarbonate (PC), UL 94V-2 Rated
Contact Resistance : 20 Milli-ohm
Cable Jacket : PVC, LSZH
Insertion Resistance : 500 Megaohm
Insertion Life : 750 Mating Cycles
Plug Retention Force : 20 lbs (89N)
Temperature : -20
~ 68
(-4
~154 )
Humidity : 10% ~ 90% RH
Approvals
Category : UL Listed, TIA/EIA-568-B.2-1 / ISO 11801
Meet : FCC CFR 47 Part 68 and IEC 603-7
Wiring Scheme : T568B
30
Materials
Current Rating : 1.5 Amps
Category 6 GXC Patching System
Description
LS C&S has developed the GXC(Giga Cross Connect) Patching Block for Category 6 grade to meet the
electrical requirements of TIA/EIA 568B.2-1 by coupling-pin technology and improve workability.
The Simple GXC(Giga Cross Connect) Patching system are available 20, 40 and 80-pair sizes for backboard
mounting variously.
LS C&S designed and developed Category 6 GXC Patching Block same IDCs distance as Category 5E that
means operators at installation site can use same Multi-Pin punch down tool as conventional.
Blocks can be easily expanded because of satisfying with Category 6 component level performance and using
SimpleTM Category 6 Solutions
coupling-pin.
The simple GXC(Giga Cross Connect) Patching Block are ideal for use in cross connects, consolidation point
(CP), and 19” rack mount panel.
The Simple GCX patching Block fully comply with the requirements set out in TIA/EIA 568-B.2-1(Cat.6),
ISO/IEC 11801. The Patch panel come with the ability to wire to a T568B or T568A configuration.
It includes base 110 Terminal Block, Wiring Base Block, Wiring Label, label holders .
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000,10G BASE-T (IEEE 802.3)
155 Mbps
100Mbps TP-PMD
1Gbps LAN
ISDN, ADSL
Analog & digital voice (VOIP) and video
Full broadband and baseband video
RoHS Compliant
Part Numbers
Description
Dimension (W x L x H) (mm)
Part Number
C6 GXC Patching Block 20-pair without leg
23.5 x 206 x 40
LS-110WB-UC6-20P-W/O
C6 GXC Patching Block without leg
41.5 x 206 x 40
LS-110WB-UC6-40P-W/O
C6 GXC Patching Block without leg
86.5 x 206 x 40
LS-110WB-UC6-80P-W/O
C6 GXC Patching Block with leg
41.5 x 206 x 80
LS-110WB-UC6-40P-W
C6 GXC Patching Block with leg
86.5 x 206 x 80
LS-110WB-UC6-80P-W
* XX Denotes Color : WH=White, BL=Blue * Fit with Empty Patch Panel
Technical Details
Electrical / Mechanical Characteristics
Current Rating: 1.5Amps
Materials
Block & IDC housing : Polycarbonate, UL 94V-0
Contact Resistance: 5Milliohm
Rated
Insulation Resistance:500 Megaohm
Approvals
Temperature: -20 ~68 (-4 ~154 )
Category : UL Listed
Humidity:10%~90%RH
31
GXC Patching System / Cat.6 110 Patch Cord
Description
The Simple GXC(Giga Cross Connect) Patching system are available 40, 80 and 160-pair sizes for mount to
standard TIA/EIA 19” racks With wire management or not.
The simple GXC(Giga Cross Connect) Patching Block are ideal for use in cross connects, consolidation point
(CP), and 19” rack mount panel.
The Simple GCX patching Block fully comply with the requirements set out in TIA/EIA 568-B.2-1(Cat.6)
,ISO/IEC 11801.
The Patch panel come with the ability to wire to a T568B or T568A configuration.
SimpleTM Category 6 Solutions
It includes base 110 Terminal Block, Wiring Base Block, Wiring Label, label holders .
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000,10G BASE-T (IEEE 802.3)
155 Mbps
100Mbps TP-PMD
1Gbps LAN
ISDN, ADSL
Analog & digital voice (VOIP) and video
Full broadband and baseband video
RoHS Compliant
Part Numbers
Description
Part Number
C6 GXC Patching Block for mount to 19” racks
LS-110WB-UC6-XXP-YY-ZZ
XX denotes the number of pair: 40P,80P,160P etc.
YY denotes total size of U(1U,2U,4U etc.)
ZZ denotes Wire Management(WM1U)
Technical Details
Electrical / Mechanical Characteristics
Current Rating : 1.5Amps
Contact Resistance : 5Milliohm
Insulation Resistance : 500 Megaohm
Temperature : -20 ~68 (-4 ~154 )
Humidity : 10%~90%RH
Materials
Block & IDC housing : Polycarbonate, UL 94V-0
Rated
Entry panel : steel
Approvals
Category : UL Listed
Description
The 110 patch cords are utilized for connecting with 110 crossconnect system used as jumper or end-user patch
cords.
Part Numbers
Description
Cat.6 110 Patch Cord, 4-Pair
XX denotes color : WH=White, BL=Blue, YL=Yellow, RD=Red,
GN=Green, GY=Grey
YYY denotes meter : 005(0.5m), 010(1m), 050(5m), etc.
32
Part Number
LS-110PCC-UC6-4-XX-YYY
SimpleTM Category 6 Solutions
Third Party Accreditation (Category 6)
33
SimpleTM Category 5e Solutions
Category 5e Channel
Category 5e U/UTP Cable 4 Pair
Category 5e U/UTP Cable 25 Pair
Category 5e F/UTP Cable 4 Pair
Category 5e SF/UTP Cable 4 Pair
Category 5e Unshielded Patch Panel
Category 5e Shielded Patch Panel
Category 5e UTP Mini Patch Panel
Category 5e Modular Jack
Category 5e Euro & 6C RJ45 Module
Category 5e Patch Cord (Unshielded / Shielded)
Category 5e 110 Block / Connecting Block
110 Patch Cord / Jumper Trough
Third Party Accreditation (Category 5e)
Category 5e Channel
Diagram
Cat.5e
Patch Cord
Cat.5e
Equipment Cord
Cat.5e
UTP Cable
Cat.5e
Patch Cord
Cat.5e
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Switching Hub
Cat.5e
Cat.5e Patch Panel
Category 5e Solutions
Cat.5e
Consolidation
Modular Jack
Point
Simple
TM
Channel
Guaranteed Channel Performances
Frequency
Attenuation
(MHz)
(dB / 100m)
(dB)
(dB)
(dB)
(dB)
(dB)
(dB)
(dB)
1.00
2.4
60.0
57.0
57.6
54.6
57.4
54.4
17.0
4.00
4.5
53.5
50.5
49.0
46.0
45.4
42.4
17.0
8.00
6.4
48.6
45.6
42.2
39.2
39.3
36.3
17.0
10.00
7.2
47.0
44.0
39.8
36.8
37.4
34.4
17.0
16.00
9.1
43.6
40.6
34.5
31.5
33.3
30.3
17.0
20.00
10.2
42.0
39.0
31.8
28.8
31.4
28.4
17.0
25.00
11.5
40.3
37.3
28.9
25.9
29.4
26.4
16.0
31.25
12.9
38.7
35.7
25.8
22.8
27.5
24.5
15.1
62.50
18.6
33.6
30.6
15.0
12.0
21.5
18.5
12.0
100.00
24.0
30.1
27.1
6.1
3.1
17.4
14.4
10.0
155.00
30.6
26.8
23.8
(-)
(-)
13.6
10.6
8.1
NEXT
PSNEXT
PSACR
ACR
ELFEXT
PSELFEXT
Return
Loss
Typical Channel Performance
Attenuation
NEXT
PSNEXT
ELFEXT
PSELFEXT
Return
Loss
(dB / 100m)
(dB)
(dB)
(dB)
(dB)
(dB)
-10%
+8
+8
+10
+10
+8
35
Category 5e U/UTP Cable 4 Pair
Conductor
Jacket (PVC/LSZH)
Insulation (HDPE/FEP)
Rip Cord (Optional)
Twisted Pair
Application
Simple
TM
Category 5e Solutions
Description
ETL, EC Verified, UL Listed
Horizontal Distribution & Backbone Cabling
Supports Fast Ethernet, Gigabit Ethernet, 155 Mb/s ATM, Multimedia
4/16 Mbps Token Ring (IEEE 802.5)
All accepted design for global commercial network installation
10/100/1000 BASE-T (IEEE 802.3)
Simplified structured cabling solution preserving long-term network investment
155 Mbps ATM
Electrical performances comply with TIA/EIA-568B.2
100Mbps TP-PMD
Specialized print legend contains footage marking from 1000 to 0 , metric from 305 to 0m and
ISDN, ADSL
dual marking footage and metric
RoHS Compliant
Part Numbers
Category 5E UTP Cable, 4-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
CMP
LSZH
UTP-E-C5G-E1VN-X
0.5X004P/(1)
UTP-E-C5G-E1VN-M
0.5X004P/(1)
UTP-E-C5G-E1VN-R
0.5X004P/(1)
UTP-E-C5G-F1VN-P
0.5X004P/(1)
UTP-E-C5G-E1ZN-X
0.5X004P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Resistance Unbalance
Unit
PVC / LSZH
Plenum
Ohms/100 m
9.38
9.38
%
5
5
Mutual Capacitance
nF/100 m
5.6
5.6
Capacitance Unbalance
pF/100 m
330
330
Characteristic Impedance
100
15%
538 @ 100 MHz
538 @ 100 MHz
Delay Skew
ns
45
45
Nominal Velocity of Propagation
%
67
68
Operating Temperature
/
-20 ~ 60 / -4 ~ 140
-20 ~ 60 / -4 ~ 140
Storage Temperature
/
Bending Radius
Packaging Type
Packaging Weight
305 m (1000ft)
lb/kft (kg/km)
Conductor Diameter / Material
36
15%
100
Ohms
ns/100 m
Propagation Delay
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
-20 ~ 80 / -4 ~ 176
-20 ~ 80 / -4 ~ 176
4 x Cable Diameter
4 x Cable Diameter
Reelex
Reelex
17 (25)
20 (30)
24 AWG, Solid Copper
24 AWG, Solid Copper
0.035 (0.90)
0.189 (4.8)
, HDPE
, PVC or LSZH (Low Smoke Zero Halogen)
0.034 (0.86)
0.181 (4.6)
, FEP
, LS-PVC (Plenum)
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / CMP - UL910 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2 / ISO 11801 Performance specifications for 4-Pair 100 Ohm Category 5E / D Cabling
Category 5e U/UTP Cable 25 Pair
Conductor
PVC or LSZH Jacket
Insulation
Centered Filler
Rip Cord (Optional)
Twisted Pair
PS Tape
Application
Backbone Cabling
Supports Fast Ethernet, Gigabit Ethernet, 155 Mb/s ATM, Multimedia
4/16 Mbps Token Ring (IEEE 802.5)
All accepted design for global commercial network installation
10/100/1000 BASE-T (IEEE 802.3)
Simplified structured cabling solution preserving long-term network investment
155 Mbps ATM
Electrical performances comply with TIA/EIA-568B.2
100Mbps TP-PMD
RoHS Compliant
ISDN, ADSL
Simple
TM
UL Listed
Category 5e Solutions
Description
Part Numbers
Category 5E UTP Cable, 25-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
LSZH
UTP-E-C5G-E1VN-X
0.5X025P/(1)
UTP-E-C5G-E1VN-M
0.5X025P/(1)
UTP-E-C5G-E1VN-R
0.5X025P/(1)
UTP-E-C5G-E1ZN-X
0.5X025P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Unit
PVC / LSZH
Ohms/100 m
9.38
%
5
Mutual Capacitance
nF/100 m
5.6
Capacitance Unbalance
pF/100 m
Characteristic Impedance
Ohms
Resistance Unbalance
330
15%
100
ns/100 m
538 @ 100 MHz
Delay Skew
ns
45
Nominal Velocity of Propagation
%
70
Operating Temperature
/
-20 ~ 60 / -4 ~ 140
Storage Temperature
/
Propagation Delay
-20 ~ 80 / -4 ~ 176
10 x Cable Diameter
Bending Radius
Packaging Type
Packaging Weight
305 m (1000 ft) / 1000m
Reel / Drum
lb/kft (kg/km)
124 (185)
24 AWG, Solid Copper
Conductor Diameter / Material
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
0.037 (0.95)
0.5 (12.7)
, HDPE
, PVC or LSZH (Low Smoke Zero Halogen)
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2 / ISO 11801 Performance specifications for 4-Pair 100 Ohm Category 5E / D Cabling
37
Category 5e F/UTP Cable 4 Pair
Conductor
Jacket (PVC/LSZH)
Insulation (HDPE)
Drain Wire
AI/Mylar Tape
Twisted Pair
Polyester Tape (Optional)
Category 5e Solutions
Description
Application
Simple
TM
Supports Fast Ethernet, Gigabit Ethernet, 155 Mb/s ATM, Multimedia
All accepted design for global commercial network installation
Simplified structured cabling solution preserving long-term network investment
Electrical performances comply with TIA/EIA-568B.2
Specialized print legend contains footage marking from 1000 to 0 , metric from 305 to 0m and
dual marking footage and metric
Reel in a Box is standard, so wire pulls through box opening for easy access
RoHS Compliant
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
Part Numbers
Category 5E FTP Cable, 4-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
LSZH
FTP-E-C5G-E1VN-X
0.5X004P/(1)
FTP-E-C5G-E1VN-M
0.5X004P/(1)
FTP-E-C5G-E1VN-R
0.5X004P/(1)
FTP-E-C5G-E1ZN-X
0.5X004P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Resistance Unbalance
Unit
PVC / LSZH
Ohms/100 m
9.38
%
5
Mutual Capacitance
nF/100 m
5.6
Capacitance Unbalance
pF/100 m
330
Characteristic Impedance
538 @ 100 MHz
Delay Skew
ns
45
Nominal Velocity of Propagation
%
67
Operating Temperature
/
-20 ~ 60 / -4 ~ 140
Storage Temperature
/
-20 ~ 80 / -4 ~ 176
4 x Cable Diameter
Bending Radius
Packaging Type
Packaging Weight
305 m (1000ft)
Reel / Reel in a Box
lb/kft (kg/km)
30 (46)
24 AWG, Solid Copper
Conductor Diameter / Material
38
15%
100
Ohms
ns/100 m
Propagation Delay
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
0.043 (1.08)
0.248 (6.3)
, HDPE
, PVC or LSZH (Low Smoke Zero Halogen)
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2 / ISO 11801 Performance specifications for 4-Pair 100 Ohm Category 5E / D Cabling
Category 5e SF/UTP Cable 4 Pair
Conductor
Jacket (PVC/LSZH)
Insulation (HDPE)
PS Tape
AI/Mylar Tape
Twisted Pair
Tinned Copper Braid
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
TM
Supports Fast Ethernet, Gigabit Ethernet, 155 Mb/s ATM, Multimedia
All accepted design for global commercial network installation
Simplified structured cabling solution preserving long-term network investment
Electrical performances comply with TIA/EIA-568B.2
Specialized print legend contains footage marking from 1000 to 0 , metric from 305 to 0m and
dual marking footage and metric
Wooden Reel is standard, so wire pulls through reel for easy access
RoHS Compliant
Category 5e Solutions
Application
ISDN, ADSL
Simple
Description
Part Numbers
Category 5E S-FTP Cable, 4-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
LSZH
SFP-E-C5G-E1VN-X
0.5X004P/(1)
SFP-E-C5G-E1VN-M
0.5X004P/(1)
SFP-E-C5G-E1VN-R
0.5X004P/(1)
SFP-E-C5G-E1ZN-X
0.5X004P/(1)
Denote : (1) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black
Technical Details
Item
Conductor DC Resistance
Unit
PVC / LSZH
Ohms/100 m
9.38
%
5
Mutual Capacitance
nF/100 m
5.6
Capacitance Unbalance
pF/100 m
Characteristic Impedance
Ohms
Resistance Unbalance
330
15%
100
ns/100 m
538 @ 100 MHz
Delay Skew
ns
45
Nominal Velocity of Propagation
%
67
Operating Temperature
/
-20 ~ 60 / -4 ~ 140
Storage Temperature
/
Propagation Delay
-20 ~ 80 / -4 ~ 176
4 x Cable Diameter
Bending Radius
Packaging Type
Packaging Weight
305 m (1000 ft) / 500 m
Reel
lb/kft (kg/km)
38 (57)
24 AWG, Solid Copper
Conductor Diameter / Material
Insulation Diameter / Material
inch (mm)
Jacket Diameter / Material
inch (mm)
0.043 (1.08)
0.248 (6.3)
, HDPE
, PVC or LSZH (Low Smoke Zero Halogen)
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance
TIA/EIA-568-B.2 / ISO 11801 Performance specifications for 4-Pair 100 Ohm Category 5E / D Cabling
39
Category 5e Unshielded Patch Panel
Category 5e Solutions
Description
These PCB 1U patch panel and 2U patch panel come complete with cable management, accessories and full
installation instructions. They fully comply with the requirements set out in ANSI/TIA/EIA-568-B.2.
Simple
TM
Application
Horizontal Distribution & Backbone Cabling
100Mbps TP-PMD
4/16 Mbps Token Ring (IEEE 802.5)
ISDN, ADSL
10/100/1000 BASE-T (IEEE 802.3)
RoHS Compliant
155 Mbps ATM
Part Numbers
Dimension (H x W)
Part Number
24-Port Category 5e Unshielded Patch Panel
1.75 x 19 (1U)
LS-PP-UC5E-24P
48-Port Category 5e Unshielded Patch Panel
3.50 x 19 (2U)
LS-PP-UC5E-48P
Description
Technical Details
Electrical / Mechanical Characteristics
Current Rating : 1.5 Amps
Housing : High Impact Flame Retardant Plastic,
Contact Resistance : 20 milli-ohm
UL 94V-0 Rated
Insertion Resistance : 500 Megaohm
Spring Wire : Phosphor Bronze Plated with 50
DC Resistance : 0.1 ohm Max.
Micro-inch (1.27 microns) Thick Gold
Voltage : 150 Vac Max.
Over 100 Micro-inch (2.54 microns)
Insertion Life : 750 Mating Cycles
Thick Nickel Undercoat
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~ 154 )
Humidity : 10% ~ 90% RH
IDC Accept : 22 ~ 26 AWG Solid Wire
Approvals
Category : UL Listed, TIA/EIA-568-B.2 / ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A/T568B
Korean Ministry of Information and
Communication Approved
40
Materials
IDC Plastic : Polycarbonate or ABS, UL 94V-0
Rated
IDC Contact : Phosphor Bronze Plated with 100
Micro-inch (2.54 microns) Minimum
Thick Tin
Panel : Steel with Black Painting
Category 5e Shielded Patch Panel
Category 5e Solutions
Description
This PCB 1U patch panel comes complete with cable management, accessories and full installation
instructions. They fully comply with the requirements set out in ANSI/TIA/EIA-568-B.2.
Application
TM
Horizontal Distribution & Backbone Cabling
Simple
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
Part Numbers
Description
24-Port Category 5e Shielded Patch Panel
Dimension (H x W)
Part Number
1.75 x 19 (1U)
LS-PP-SC5E-24P
Technical Details
Electrical / Mechanical Characteristics
Materials
Current Rating : 1.5 Amps
Housing : ABS, UL 94V-0 Rated
Contact Resistance : 20 Milli-ohm
Jack Spring Wire : Phosphor Bronze with 50 Micro-
Insulation Resistance : 500 Megaohm
inch (1.27 microns) Thick Gold
DC Resistance : 0.1 ohm Max
Over 80 Micro-inch (2.03 microns)
Dielectric Withstanding Voltage : 1000 V
Thick Nickel Undercoat
Data Transmission Rates : 100 Mbps
IDC Plastic : Polycarbonate or ABS, UL 94V-0 Rated
Plug Insertion Life : 750 Cycles
IDC Contact : Phosphor Bronze with 100 Micro-inch
Plug Retention Force : 30 lbs (133N)
Temperature : -20
~ 50
(-4
~ 154 )
(2.54 microns) Thick Tin
Panel : Powder Coated Steel with Gray Color
Humidity : 10% ~ 90%RH
IDC Accept : 22~26 AWG Solid Wire
Approvals
Category : UL Listed, TIA/EIA-568-B.2 / ISO 11801
Category 5e Transmission Performance
Wiring Scheme : T568A/T568B
41
Category 5e UTP Mini Patch Panel
Category 5e Solutions
Description
This PCB 1U 12Port Mini Patch Panel comes complete with cable management, accessories and full
installation instructions. It is half size of general Patch Panel for compact and flexible arrangement on system
Rack. It fully complies with the requirements set out in TIA/EIA 568-B.2(Category5e), ISO/IEC 11801(Class D)
& RJ-45 of 47 CFR part 68, TIA/EIA. The Patch Panel comes with the ability to wire to a T568B or T568A
Simple
TM
configuration.
Application
ISDN, ADSL
Horizontal Distribution & Backbone Cabling
Analog & digital voice (VOIP) and video
4/16 Mbps Token Ring (IEEE 802.5)
Full broadband and baseband video
10/100/1000 BASE-T (IEEE 802.3)
RoHS Compliant
155 Mbps
100Mbps TP-PMD
Part Numbers
Description
Dimension (L x W) (mm)
Part Number
1.75” X 9.5” (1U)
LS-PPM-UC5E-12P
180° 12-Port Category 5e Unshielded
Mini Patch Panel with wire management
Technical Details
Electrical / Mechanical Characteristics
Current Rating : 1.5 Amps
Housing : High Impact Flame Retardant Plastic,
Contact Resistance : 20 milli-ohm
UL 94V-0 Rated
Insertion Resistance : 500 Megaohm
Spring Wire : Phosphor Bronze Plated with 50
DC Resistance : 0.1 ohm Max.
Micro-inch (1.27 microns) Thick Gold
Voltage : 150 Vac Max.
Over 100 Micro-inch (2.54 microns)
Insertion Life : 750 Mating Cycles
Thick Nickel Undercoat
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~ 154 )
Humidity : 10% ~ 90% RH
IDC Accept : 22 ~ 26 AWG Solid Wire
Approvals
Category : UL Listed, TIA/EIA-568-B.2 / ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A/T568B
Korean Ministry of Information and
Communication Approved
42
Materials
IDC Plastic : Polycarbonate or ABS, UL 94V-0
Rated
IDC Contact : Phosphor Bronze Plated with 100
Micro-inch (2.54 microns) Minimum
Thick Tin
Panel : Steel with Black Painting
Category 5e Modular Jack
Description
LS SimpleTM Category 5e modular jacks are designed and manufactured to meet today s and tomorrow s
demanding international standards. They take into consideration the need for reliable and quick installations.
The jack is individually terminated using Insulation Displacement Connectors (IDC) giving assurance of wire
connection when using a punch down tool.
User instructions and basic wiring layout for standard configuration are included.
The LS SimpleTM Modular Jack comes with the ability to wire to a T568A or T568B configuration and fully
complies with TIA/EIA-568-B.2 (Category 5e) and ISO/IEC 11801(Class D) component performances
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
Category 5e Solutions
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
RoHS Compliant
Simple
TM
Part Numbers
Part Number
Description
90 Category 5e Unshielded Modular Jack with T568A/B Label
LS-MJ-UC5E-XX
90 Category 5e Shielded Modular Jack with T568A/B Label
LS-MJ-SC5E-WH
90 Category 5e Unshielded Modular Jack with T568A/B Label and Shutter
LS-MJ-UC5E-XX-S
90 Category 5e Unshielded Modular Jack with T568A/B Label, Tool-Less
LS-MJ-UC5E-XX-TL
180 Category 5e Unshielded Modular Jack of RIDC with T568A/B Label
LS-MJ-UC5E-XX-RIDC
180 Category 5e Shielded Modular Jack of RIDC with T568A/B Label
LS-MJ-SC5E-WH-RIDC
XX denotes color : WH=White, IV=Ivory, BK=Black, BL=Blue, RD=Red
* Note : Shielded modular jack is available in white color only
Wall plate type is available in white and ivory color only
Technical Details
Electrical / Mechanical Characteristics
Materials
Housing : High Impact Flame Retardant Plastic, UL
Current Rating : 1.5 Amps
94V-0 Rated
DC Resistance : 0.1 ohm Max.
Spring Wire : Phosphor Bronze Plated with 50
Voltage : 150 Vac Max.
Insertion Life : 750 Mating Cycles
Micro-inch (1.27 microns) Thick Gold
Plug Retention Force : 20 lbs (89N)
Over 100 Micro-inch (2.54 microns)
Temperature : -40
~ 68
(-40
~ 154 )
Thick Nickel Undercoat
Humidity : 10% ~ 90% RH
IDC Plastic : Polycarbonate or ABS, UL 94V-0 Rated
IDC Accept : 22 ~ 26 AWG Solid Wire
IDC Contact : Phosphor Bronze Plated with 100
Approvals
Category : UL Listed, TIA/EIA-568-B.2 / ISO 11801
Meet : FCC CFR 47 Part 68
Wiring Scheme : T568A/T568B
Micro-inch (2.54 microns) Minimum
Thick Tin
Shielded : Copper Zinc Alloy, Pre-Plated with
Bright Nickel
Korean Ministry of Information and Communication
Approved
43
Category 5e Euro & 6C RJ45 Module
Description
The Enhanced Category 5e compact module is designed to provide a shallow solution for wall outlets. They
are the ideal solution wherever back-box depth is an issue.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
Category 5e Solutions
RoHS Compliant
Part Numbers
Description
Dimension (L x W) (mm)
Part Number
50 x 25
LS-MJ-EU-UC5E-WH
38.5 X 25
LS-MJ-6C-UC6-WH
Shuttered Low Profile Cat.5e Euro Module.
RJ45 (8P8C) T568A/T568B
Shuttered Low Profile Cat.5e 6C Module.
Simple
TM
RJ45 (8P8C) T568A/T568B
Technical Details
Electrical / Mechanical Characteristics
Housing : High Impact Flame Retardant Plastic,
Current Rating : 1.5 Amps
UL 94V-0 Rated
Contact Resistance : 20 Milli-ohm
DC Resistance : 0.1 ohm Max.
Voltage : 150 Vac Max.
Insertion Life : 750 Mating Cycles
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~ 154 )
Humidity : 10% ~ 90% RH
IDC Accept : 24 ~ 26 AWG Solid Wire
Approvals
Category : UL Listed, TIA/EIA-568-B.2 / ISO 11801
Meet : FCC Part 68
Wiring Scheme : T568A/T568B
44
Materials
Category 5e Patch Cord (Unshielded / Shielded)
Description
LS SimpleTM Category 5e patch cords are factory terminated, providing the quality required to support your
channel requirements. They are fully booted and have clip protection for simple removal. They offer a high
performance alternative to satin modular line cords where crosstalk, EMI, or distance may be considerations.
Cable consists of pairs of 24 AWG (0.51mm) wire, each four pair twisted at a different lay length.
Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
Category 5e Solutions
RoHS Compliant
Part Numbers
Part Number
Description
LS-PC-UC5E-X-YY-ZZZ
Category 5e Shielded Patch Cord with T568B Wiring
LS-PC-SC5E-X-YY-ZZZ
TM
Category 5e Unshielded Patch Cord with T568B Wiring
Simple
X denotes jacket material : V=PVC, Z=LSZH
YY denotes color : WH=White, BL=Blue, YL=Yellow, RD=Red, GN=Green, GY=Grey
ZZZ denotes meter : 005(0.5m), 010(1m), 050(5m), etc
Technical Details
Electrical / Mechanical Characteristics
Materials
Current Rating : 1.5 Amps
Housing : Polycarbonate, UL 94V-2 Rated
Contact Resistance : 20 Milliohm
Cable Jacket : PVC, LSZH
Insertion Resistance : 500 Megaohm
Insertion Life : 750 Mating Cycles
Plug Retention Force : 20 lbs (89N)
Temperature : -20
~ 68
(-4
~ 154 )
Humidity : 10% ~ 90% RH
Approvals
Category : UL Listed, TIA/EIA-568-B.2 / ISO 11801
Meet : FCC CFR 47 Part 68 and IEC 603-7
Wiring Scheme : T568B
45
Category 5e 110 Block / Connecting Block
110 Block
Description
The 110 wiring blocks accept 22~26 AWG conductors. Blocks are available in 25, 50 and 100 pair sizes for
backboard mounting.
Part Numbers
Dimension (W x L x H) (mm)
Part Number
25-Pair, without Mounting Legs & Label Holders
214 x 38 x 40
LS-110WB-25P-W/O
50-Pair, without Mounting Legs & Label Holders
214 x 42 x 40
LS-110WB-50P-W/O
100-Pair, without Mounting Legs & Label Holders
214 x 88 x 40
LS-110WB-100P-W/O
50-Pair, with Mounting Legs & Label Holders
272 x 47 x 87
LS-110WB-50P-W
100-Pair, with Mounting Legs & Label Holders
272 x 92 x 87
LS-110WB-100P-W
Simple
TM
Category 5e Solutions
Description
Technical Details
Material : PC, UL 94V-0 Rated
Connecting Block
Description
The 110 connecting blocks utilize double-ended insulation displacement contacts (IDC) that terminate
22-26 AWG solid or stranded conductors. The blocks are availabel in 3, 4, and 5-pair sizes with the
appropriate color-coding. The connecting Blocks are complete with TIA/EIA 568B.2
(Category5e) and ISO/IEC 11801(Class D) performances.
Part Numbers
Number
Part Number
3-Pair
Blue / Orange / Green
LS-110CB-3
4-Pair
Blue / Orange / Green / Brown
LS-110CB-4
5-Pair
Blue / Orange / Green / Brown / White
LS-110CB-5
Part
Technical Details
Material : PC, UL 94V-0 Rated
46
110 Patch Cord / Jumper Trough
110 Patch Cord
Description
The 110 patch cords are utilized for connecting with 110 cross-connect system used as jumper or end-user
patch cords.
Description
Category 5e Solutions
Part Numbers
Part Number
LS-110PCC-1-XX-YYY
110 Patch Cord, 2-Pair
LS-110PCC-2-XX-YYY
110 Patch Cord, 3-Pair
LS-110PCC-3-XX-YYY
110 Patch Cord, 4-Pair
LS-110PCC-4-XX-YYY
TM
110 Patch Cord, 1-Pair
Simple
YY denotes color : WH=White, BL=Blue, YL=Yellow, RD=Red, GN=Green, GY=Grey
ZZZ denotes meter : 005(0.5m), 010(1m), 050(5m), etc
Jumper Trough
Description
The 110 Jumper troughs are fire-retardant molded plastic frame, which serves as a horizontal cable
management for routing of patch cords and cross-connect wire.
Part Numbers
Description
Part Number
110 Jumper Trough, 5 Wire Hangers without Legs
LS-JT-T1-W/O
110 Jumper Trough, 5 Wire Hangers with Legs
LS-JT-T2-W
Technical Details
Material : PC, UL 94V-0 Rated
47
Simple
TM
Category 5e Solutions
Third Party Accreditation (Category 5e)
48
SimpleTM Voice & Telephone
Category 3 U/UTP Cable 25 ~ 500 Pair
Unshielded Voice Patch Panel
Category 3 U/UTP Cable 25 ~ 500 Pair
Jacket (PVC/LSZH)
25~ 500 Pair
Rip Cord (Optional)
SimpleTM Voice & Telephone
Description
Application
All accepted design for global commercial network installation
Backbone Cabling
Simplified structured cabling solution preserving long-term network investment
4 Mbps Token Ring (IEEE 802.5)
Electrical performances comply with TIA/EIA-568B.2
10 BASE-T (IEEE 802.3)
Part Numbers
Category 3 UTP Cable, 25-Pair
Description
Flame Retardant Grade
Part Numbers
CMX
CM
CMR
UTP-G-C3G-(1)1VN-X
0.5X(2)P/(3)
UTP-G-C3G-(1)1VN-M
0.5X(2)P/(3)
UTP-G-C3G-(1)1VN-R
0.5X(2)P/(3)
Denote : (1) E: PE, S: Foamskin
(2) ###: #Pair(004-500Pair)
(3) WH: White, BL: Blue, GY: Gray, VI: Violet, OR: Orange, RD: Red, GN: Green, YL: Yellow, BK: Black,
Technical Details
Item
Conductor DC Resistance
Unit
PVC / LSZH
Ohms/100 m
9.38
%
5
Mutual Capacitance
nF/100 m
6.6
Capacitance Unbalance
pF/100 m
Characteristic Impedance
Ohms
Resistance Unbalance
15%
45
Delay Skew
ns
Nominal Velocity of Propagation
%
70
Operating Temperature
/
-20 ~ 60 / -4 ~ 140
Storage Temperature
/
Packaging Type
-20 ~ 80 / -4 ~ 176
10 x Cable Diameter
Bending Radius
Option
Reel / Drum
24 AWG, Solid Copper
Conductor Diameter / Material
50
330
100
Insulation Diameter / Material
inch (mm)
0.031 (0.80)
Jacket Diameter / Material
inch (mm)
0.39 (10.0)
Safety Standard, Performance Standard
UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666
Approvals Performance
TIA/EIA-568-B.2 Performance specifications for multi-pairs 100 Ohm Category 3 Cabling
, HDPE
, PVC
Unshielded Voice Patch Panel
Description
These PCB 1U Voice Patch Panels are offered with 8 contact inserts wired to KRONE IDC or 110 terminal
SimpleTM Voice & Telephone
blocks. It meets all requirements set forth in ANSI/TIA/EIA-568-B.2 when using UTP cabling rated to 16MHz.
Part Numbers
Dimension (H xW)
Part Number
25-Port Category 3 Unshielded Voice Patch Panel
1.75 x 19 (1U)
LS-TPP-25P
50-Port Category 3 Unshielded Voice Patch Panel
1.75 x 19 (1U)
LS-TPP-50P
Description
Technical Details
Electrical / Mechanical Characteristics
Materials
Housing : High Impact Flame Retardant Plastic,
Current Rating : 1.5 Amps
Contact Resistance : 20 Milli-ohm Max.
UL 94V-0 Rated
Insertion Resistance : 500 Megaohm Min.
IDC Plastic : Polycarbonate, UL 94V-0 Rated
DC Resistance : 0.1 ohm Max.
Panel : Steel with Black Painting
Voltage : 150 Vac Max.
Insertion Life : 750 Mating Cycles
Plug Retention Force : 20 lbs (89N)
Temperature : -40
~ 68
(-40
~ 154 )
Humidity : 10% ~ 90% RH
IDC Accept : 24 ~ 26 AWG Standard Wire
Approvals
Category : UL Listed, TIA/EIA-568-B.2
Meet : FCC Parts 68
Wiring Scheme : USOC
51
Faceplate
Empty Patch Panel / Faceplate / Back Box
Adaptor Insert
Surface Mount Box / Modular Plug
SimpleTM Outlet
Faceplate
Description
These faceplates attractively house keystone jacks, in addition F TV connectors or LC, SC, ST fiber optic
connectors that you can select and snap in according to your needs.
Euro RJ45 Faceplate & Bezel
Part Numbers
Description
Outer Dimension
Inner Dimension
(L x W) (mm)
(L x W) (mm)
86 x 86
50 x 50
Single Gang Bevelled Frame
Part Number
LS-FP-EU-BF-2
Single Gang Flat Frame
86 x 86
50 x 50
LS-FP-EU-FF-2
Double Gang Bevelled Frame
86 x 146
50 x 100
LS-FP-EU-BF-4
Double Gang Flat Frame
86 x 146
50 x 100
LS-FP-EU-FF-4
1/2 Blank Bezel
50 x 25
-
LS-FP-EU-BB-1/2
1/4 Blank Bezel
50 x 12.5
-
LS-FP-EU-BB-1/4
Outer Dimension
Inner Dimension
Part Number
** Fit with Euro Module
Square Faceplate
(L x W) (mm)
(L x W) (mm)
1-Port British Faceplate W/Shutter & Station ID
86 x 86
50 x 50
LS-FP-SF-1
2-Port British Faceplate W/Shutter & Station ID
86 x 86
50 x 50
LS-FP-SF-2
4-Port British Faceplate W/Shutter & Station ID
86 x 86
50 x 50
LS-FP-SF-4
1-Port Square Faceplate W/Station ID, Angled Shutter
86 x 86
50 x 50
LS-FP-SA-1
2-Port Square Faceplate W/Station ID, Angled Shutter
86 x 86
50 x 50
LS-FP-SA-2
Outer Dimension
Inner Dimension
Part Number
(L x W) (mm)
(L x W) (mm)
TM
Description
Outlet
Part Numbers
** Fit with RJ45 Modular Jack
LJ6C RJ45 Faceplate & Bezel
Part Numbers
Description
Single Gang British Bevelled 6C Frame
86 x 86
38.5 x 50
Double Gang British Bevelled 6C Frame
86 x 146
38.5 x 100
LS-FP-6C-BF-4
1/2 6C Blank Bezel
38.5 x 25
-
LS-FP-6C-BB-1/2
1/4 6C Blank Bezel
38.5 x 12.5
-
LS-FP-6C-BB-1/4
LS-FP-6C-BF-2
** Fit with 6C Module
Technical Details
•Housing : High Impact Flame Retardant Plastic, UL 94V-0 Rated
53
Empty Patch Panel / Faceplate / Back Box
Empty Patch Panel
Description
These unshielded/shielded empty patch panels come complete with cable management accessories and full
installation instructions. Empty Panel holds the Shield Modular Jack, un-shield Modular Jack, Fiber Adaptor &
coupler etc.
Part Numbers
Description
Dimension
Part Number
(L x W) (mm)
24-Port Empty Patch Panel
1.75 X 19(1U)
LS-PP-24P-E
24-Port Empty Patch Panel with Wire Management
1.75 X 19(1U)
LS-PP-24P-E-WM
48-Port Empty Patch Panel
3.50 X 19(2U)
LS-PP-48P-E
48-Port Empty Patch Panel with Wire Management
3.50 X 19(2U)
LS-PP-48P-E-WM
It is used for keystone & SI type MJ, Shielded & Unshielded
Faceplate
Description
These faceplates are ideal for the installation of keystone jacks, available in 1, 2, 4 and 6 port or blank. Insert
the units into plastic inserts before snap in the faceplates.
Part Numbers
Outlet
Description
Dimension
Part Number
TM
(L x W) (mm)
1-Port Single Gang Faceplate
L113 x W70
LS-FP-US-1PORT
2-Port Single Gang Faceplate
L113 x W70
LS-FP-US-2PORT
4-Port Single Gang Faceplate
L113 x W70
LS-FP-US-4PORT
6-Port Single Gang Faceplate
L113 x W70
LS-FP-US-6PORT
Back Box
Description
The back box is designed to mount into a wall, floor, or other flat surface. Convenient molded-in rear and
side cable entries easily accommodate Cat5e or Cat6 Cable or optical fiber. Unit includes screws and doublesided tape for mounting, rubber-door and cable tie.
Part Numbers
Description
Dimension
Part Number
(L x W) (mm)
Single Gang Mounted Box, H27mm
86 x 86
LS-BB-8686-27
Single Gang Mounted Box, H37mm
86 x 86
LS-BB-8686-37
Single Gang Mounted Box, H47mm
86 x 86
LS-BB-8686-47
Double Gang Mounted Box, H27mm
86 x 147
LS-BB-86147-27
Double Gang Mounted Box, H37mm
86 x 147
LS-BB-86147-27
Single Gang Mounted Box (US), H38mm
115 x 72
LS-BB-11572-38
Technical Details
Housing : High Impact Flame Retardant Plastic, UL 94V-0 Rated
54
Adaptor Insert
Description
These adapter inserts are ideal for the installation of F NTSC-TV connectors or LC, SC, ST fiber optic
connectors. Insert the units into plastic inserts before snap in the faceplates.
Application
Telecommunication Networks, Fiber To The Home (FTTH), Instrumentation, Fiber optic sensors,
LANs, and CATV.
Part Numbers
Part Number
Description
Duplex LC/PC Insert Assembly, S.M., Ceramic (Zirconia) Sleeve
LS-AI-US-LC-SM
Duplex LC/PC Insert Assembly, M.M., Phosphor Bronze Sleeve
LS-AI-US-LC-MM
Simplex SC/PC Insert Assembly, S.M., Ceramic (Zirconia) Sleeve
LS-AI-US-SC-SM
Simplex SC/PC Insert Assembly, M.M., Phosphor Bronze Sleeve
LS-AI-US-SC-MM
LS-AI-US-ST-SM
Simplex ST/PC Insert Assembly, M.M., Phosphor Bronze Sleeve
LS-AI-US-ST-MM
Outlet
Simplex ST/PC Insert Assembly, S.M., Ceramic (Zirconia) Sleeve
TM
Technical Details
Electrical / Mechanical Characteristics
Insertion Loss :
0.15dB Typical
Durability : Max. 0.15dB Increase After 500-Cycle
Retention Force : 200 ~ 600g
Temperature : -20
~ 70
(-4
~ 158 )
High-Performance Interconnections Offer Very Low Insertion Loss
Ceramic (Zirconia) or Low-cost Phosphor Bronze Alignment Sleeves
Adapters are Supplied with Dust Caps
Environmental Stable
Materials
Housing : High Impact Flame Retardant Plastic, UL 94V-0 Rated
Sleeve : Ceramic (Zirconia) or Singlemode / Phosphor Bronze for Multimode
Spring Plate : Stainless Steel
Part Numbers
Description
Part Number
Simplex F NTSC-TV Insert Assembly
LS-AI-US-TV-1
Blank Insert
LS-AI-US-BI-1
System Box Housing
LS-Housing
55
Surface Mount Box / Modular Plug
Surface Mount Box
Description
These surface mount boxes accommodate telecommunication ports & color icons. It is available in 8-conductor
Keystone Jacks. The unit comes with mounting screws and double-sided adhesive tape for quick installation.
Part Numbers
Dimension
Description
Part Number
(L x W x H) (mm)
65.2 x 48.2 x 26.8
LS-SMB-1PORT
2-Port Surface Box with Station ID & Shutter
65.2 x 76.0 x 26.8
LS-SMB-2PORT
4-Port Surface Box with Station ID & Shutter
65.2 x 131.8 x 30.0
LS-SMB-4PORT
6-Port Surface Box with Station ID & Shutter
65.2 x 189.0 x 30.0
LS-SMB-6PORT
65.2 x 48.2 x 26.8
LS-SMB-UC5E-1PORT
2-Port Surface Box with Station ID & Shutter
65.2 x 76.0 x 26.8
LS-SMB-UC5E--2PORT
4-Port Surface Box with Station ID & Shutter
65.2 x 131.8 x 30.0
LS-SMB-UC5E--4PORT
6-Port Surface Box with Station ID & Shutter
65.2 x 189.0 x 30.0
LS-SMB-UC5E--6PORT
1-Port Surface Box with Station ID & Shutter
65.2 x 48.2 x 26.8
LS-SMB-UC6-1PORT
2-Port Surface Box with Station ID & Shutter
65.2 x 76.0 x 26.8
LS-SMB-UC6-2PORT
4-Port Surface Box with Station ID & Shutter
65.2 x 131.8 x 30.0
LS-SMB-UC6-4PORT
6-Port Surface Box with Station ID & Shutter
65.2 x 189.0 x 30.0
LS-SMB-UC6-6PORT
1-Port Surface Box with Station ID & Shutter
Cat. 5e Assembled
1-Port Surface Box with Station ID & Shutter
Cat. 6 Assembled
Outlet
Technical Details
TM
Material : High Impact Flame Retardant Plastic, UL 94V-0 Rated
Modular Plug
Part Numbers
Description
Part Number
8P8C for Round Cable, Stranded & Solid Wires Used (Category 5e)
LS-MP-UC5E-RJ45
8P8C for Round Cable, Stranded & Solid Wires Used (Category 6)
LS-MP-UC6-RJ45
6P4C for Round Cable, Stranded & Solid Wires Used
LS-MP-RJ11-CR
6P4C for for Flat Cable, Stranded Wire
LS-MP-RJ11-CF
Technical Details
Technical Details
Electrical / Mechanical Characteristics
Materials
Rated Voltage, Current : 30V AC at 1.5A
Housing : Polycarbonate (PC)
Contact Resistance : 20 Milli-ohm Max.
Conacts : Copper Alloy Selective Gold Over
Nickel Plating
Dielectric Strength : 1000V AC (RMS)
Insulation Resistance : 500 Megaphm Min.
Cable-to-Plug, Tensile Strength : 20 Ibs (89N) Min.
Durability : 750-Cycle Min.
Temperature : -20
~ 80
(-4 ~176 )
Specification
Meet : FCC CFR 47 Part 68 and IEC 603-7
56
Indoor Fiber Optic Cables
All Dielectric Single Jacketed Central Tube
900um 2fiber buffered Aramid yarn strength member
900um tight buffered Glass yarn strength member
900um tight buffered Aramid yarn strength member
ONFR(riser rated), OFNP(plenum rated) or LSZH rated
Micro Distribution Cable
Outdoor Fiber Optic Cables
All Dielectric Single Jacket Non-Armor Loose Tube Cable
All Dielectric Single Jacketed Multi Loose Tube with Polyamide Sheath for Insect-resistant
Fiber Optic Connectivit
Optical Fiber Distribution / Adaptor & Connector
LS Fiber Distribution Frame with Module Panel & Gland
LS-SC Field Installable Optical Connector
Installation Manual for Field Installable Optical Connector
Fiber Optic Jumper Cord & Fiber Optic Pigtail
SimpleTM Fiber Solutions
Part Numbers (Indoor)
Select Fiber Type
Fiber Count : 2 digit No.
Sheath Color
SC = 9/125
SE = 9/125
HC = 62.5/125
HG = 50/125
MC = 50/125
MG = 50/125
MX = 50/125
Ex. 6 Fiber Count : 06, 24Fiber Count : 24
YL = Yellow
OR = Orange
AQ = Aqua
BK = Black
(ITU-T G652A,B)
(ITU-T G652C,D)
Standard
1 Gbe
Standard
1 Gbe
10 Gbe 300 meter Link Length
R = UL TYPE OFNR
P = UL TYPE OFNP
Z = LSZH TYPE
16 = 1.6 mm Diameter
18 = 1.8 mm Diameter
20 = 2.0 mm Diameter
24 = 2.4 mm Diameter
29 = 2.9 mm Diameter
Part Numbers (Outdoor)
Select Central Strength Member
Select Jacket Type
Select Fiber Type
D: FRP
M: Steel wire
E..E: Polyethylene
Z..Z: LSZH
SC = 9/125
SE = 9/125
HC = 62.5/125
HG = 50/125
MC = 50/125
MG = 50/125
MX = 50/125
Select Outer Strength Member
Select Core Type
G: Glass yarn
K: Aramid
B: Dry Core
J: Jelly Filled
(ITU-T G652A,B)
(ITU-T G652C,D)
1 Gbe
Extended Distance
1 Gbe
10 Gbe 300 meter Link Length
10 Gbe 300 meter Link Length
Select Fiber Count
Select Fiber Type
SE = 9/125
Max. Span(m)
Select Fiber Type
SC = 9/125
SE = 9/125
(ITU-T G652A,B)
(ITU-T G652C,D)
LS Fiber Optic Loose Tube Cable (Indoor)
All Dielectric Single Jacketed Central Tube
Description / Applications
All dielectric Single Jacket Central Loose Tube cable is a UV-stabilized,
fully water blocked cable for outdoor duct applications (PE outer jacket)
or Indoor/Outdoor applications (LSZH outer jacket)
Loose tube design provides stable and highly reliable transmission
parameters for a variety of voice, data, video and imaging applications.
Compact design for limited conduit space
RoHS (Restriction of the use of Certain Hazardous Substances Directive)
complied
Optical Fiber
Filling Compound
Loose Buffer Tubes
Glass Yarns
Ripcord
Specification
Outer Jacket
Telcordia GR-20-CORE
IEC 60793 / IEC 60794
ITU-T G652
12-Fiber Cable
Options
Fiber - Single mode, 50 , 62.5 multi mode available
Sequential meter or footage markings
Outer jacket : Black UV- and moisture-resistant Polyethylene or LSZH
(Low Smoke Zero Halogen)
Optical Fiber
Filling Compound
Color Identification
Loose Buffer Tubes
01 - Blue
07 - Red
13 - Blue / Single stripe
19 - Red / Single stripe
02 - Orange
08 - Black
14 - Orange / Single stripe
20 - Natural
Glass Yarns
03 - Green
09 - Yellow
15 - Green / Single stripe
21 - Yellow / Single stripe
Ripcord
04 - Brown
10 - Violet
16 - Brown / Single stripe
22 - Violet / Single stripe
05 - Slate
11 - Rose
17 - Slate / Single stripe
23 - Rose / Single stripe
06 - White
12 - Aqua
18 - White / Single stripe
24 - Aqua / Single stripe
Outer Jacket
24-Fiber Cable
Mechanical Characteristics
Storage Temperature : -20 to + 70
/ Operating Temperature : -10 to + 60
SimpleTM Fiber Solutions
Fiber
Count
Nominal
Diameter
Nominal
Weight
Maximum Tensile Load
Short Term Long Term
Crush Load
Short Term
Long Term
Minimum Bend Radius
Loaded
Installed
[mm]
[inch]
[kg/km]
[lb/kft]
[N]
[N]
[N/cm]
[N/cm]
[mm]
[inch] [mm]
[inch]
2
6.3
0.25
45
0.10
1200
600
220
110
126
4.96
63
2.51
4
6.3
0.25
45
0.10
1200
600
220
110
126
4.96
63
2.51
6
6.3
0.25
45
0.10
1200
600
220
110
126
4.96
63
2.51
8
6.3
0.25
45
0.10
1200
600
220
110
126
4.96
63
2.51
10
6.3
0.25
45
0.10
1200
600
220
110
126
4.96
63
2.51
12
6.3
0.25
45
0.10
1200
600
220
110
126
4.96
63
2.51
16
6.8
0.27
55
0.12
1200
600
220
110
136
5.35
68
2.71
18
6.8
0.27
55
0.12
1200
600
220
110
136
5.35
68
2.71
24
6.8
0.27
55
0.12
1200
600
220
110
136
5.35
68
2.71
Part Numbers
LSZH RATED
: CT
RISER RATED : CT
PLENUM RATED: CT
ZSJNA
RSJNA
PSJNA
Transmission Performance
9/125
50/125
Standard
50/125
Gigabit
50/125
10Gigabit
62.5/125
Standard
52.5/125
Gigabit
(1310/1550nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
0.4/0.3
3.0/1.0
3.0/1.0
3.0/1.0
3.5/1.0
3.5/1.0
-
500/500
500/500
1500/500
200/500
200/500
10Gbps
-
-
-
300
-
-
1Gbps
-
-
550/550
-
-
250/550
Attenuation(dB/km) Typical values
Minimum Bandwidth (MHz km)
Ethernet Link Distance (m)
58
LS Fiber Optic Distribution Cable (Indoor)
900um 2fiber buffered Aramid yarn strength member
Description / Applications
Fiber to the desk cable for very high speed multimedia application
Rugged construction : 2 fiber buffer structure with individually protected tubes
Color coded tubes to identify transmitting and receiving fibers
Small size and light weight
Simplify pulling and installation work
Colored Optical Fiber
0.9mm 2Fiber
Specification
Aramid yarn
ISO/IEC 11801
Telcordia GR-409-CORE
ANSI/ ICEA S-83-596
Outer Jecket
Options
Fiber - Single mode, 50 , 62.5 multi mode available
Outer Jacket color
- Single Mode : Yellow
- 62.5/125μm 1Gbe : Orange
- 50/125 1Gbe : Orange
- 50/125 10Gbe : Aqua
Outer jacket : PVC or LSZH (Low Smoke Zero Halogen)
Color of Buffer
Color of Fiber
01 - Blue
07 - Red
01 - Blue
02 - Orange
08 - Black
02 - Orange
03 - Green
09 - Yellow
04 - Brown
10 - Violet
05 - Grey
11 - Pink
06 - White
12 - Aqua
Mechanical Characteristics
/ Operating Temperature : 0 to + 60
Fiber
Count
Nominal
Diameter
Nominal
Weight
Maximum Tensile Load
Short Term Long Term
Crush Load
Short Term
Long Term
Minimum Bend Radius
Loaded
Installed
[mm]
[inch]
[kg/km]
[lb/kft]
[N]
[N]
[N/cm]
[N/cm]
[mm]
[inch] [mm]
[inch]
2
2.9
0.11
10
0.02
300
150
35
13
58
2.28
29
1.15
4
4.5
0.18
20
0.04
660
300
35
13
90
3.54
45
1.79
6
5.2
0.20
23
0.05
660
300
35
13
104
4.09
52
2.07
8
5.3
0.21
25
0.06
660
300
35
13
106
4.17
53
2.11
12
5.7
0.22
30
0.07
660
300
35
13
114
4.49
57
2.27
16
6.0
0.24
35
0.08
660
300
35
13
120
4.72
60
2.39
24
6.7
0.26
40
0.09
660
300
35
13
134
5.28
67
2.67
Part Numbers
LSZH RATED
: 2DT
RISER RATED : 2DT
PLENUM RATED: 2DT
Z
R
P
SimpleTM Fiber Solutions
Storage Temperature : -10 to + 70
Transmission Performance
9/125
50/125
Standard
50/125
Gigabit
50/125
10Gigabit
62.5/125
Standard
52.5/125
Gigabit
(1310/1550nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
0.5/0.4
3.0/1.0
3.0/1.0
3.0/1.0
3.5/1.0
3.5/1.0
-
500/500
500/500
1500/500
200/500
200/500
10Gbps
-
-
-
300
-
-
1Gbps
-
-
550/550
-
-
250/550
Attenuation(dB/km) Typical values
Minimum Bandwidth (MHz km)
Ethernet Link Distance (m)
59
LS Fiber Optic Distribution Cable (Indoor)
900um tight buffered Glass yarn strength member
Description / Applications
Distribution cables are rugged, high performance optical communication
cables for inside plant installations
Backbone & Computer Room Cabling
Compact design for limited conduit space
RoHS (Restriction of the use of Certain Hazardous Substances Directive)
complied
Optical Fiber
0.9mm Buffered Fiber
Glass Yarns
Sub-unit Jacket
Specification
Ripcord
ISO/IEC 11801
Telcordia GR-409-CORE
ANSI/ ICEA S-83-596
Coated Central
Strenght Member
Options
Fiber - Single mode, 50 , 62.5 multi mode available
Sub-unit & Outer Jacket color
- Single Mode : Yellow
- 62.5/125 1Gbe : Orange
- 50/125 1Gbe : Orange
- 50/125 10Gbe : Aqua
If the cable will be used indoor/outdoor applications, outer cable jacket
shall be black
Outer jacket : PVC or LSZH (Low Smoke Zero Halogen)
Subunit Identification
The identification code & number is printed on the sub-unit jacket every
10 cm (eg. SM#1, SM#2)
Ripcord
Outer Jacket
Sub-Unit Construction
Single Unit Construction
Color of Buffer
01 - Blue
07 - Red
13 - Blue / Black dash
19 - Red / Black dash
02 - Orange
08 - Black
14 - Orange / Black dash
20 - Black / White dash
03 - Green
09 - Yellow
15 - Green / Black dash
21 - Yellow / Black dash
04 - Brown
10 - Violet
16 - Brown / Black dash
22 - Violet / Black dash
05 - Grey
11 - Pink
17 - Grey / Black dash
23 - Pink / Black dash
06 - White
12 - Aqua
18 - White / Black dash
24 - Aqua / Black dash
Mechanical Characteristics
Storage Temperature : -20 to + 70
SimpleTM Fiber Solutions
Constuction
/ Operating Temperature : -10 to + 60
Fiber
Count
Nominal
Diameter
Nominal
Weight
Maximum Tensile Load
Short Term Long Term
Crush Load
Short Term
Long Term
Minimum Bend Radius
Loaded
Installed
[mm]
[inch]
[kg/km]
[lb/kft]
[N]
[N]
[N/cm]
[N/cm]
[mm]
[inch] [mm]
[inch]
2
4.5
0.18
25
0.06
660
300
35
13
90
3.54
45
1.79
4
5.3
0.21
30
0.07
660
300
35
13
106
4.17
53
2.11
6
5.7
0.22
35
0.08
660
300
35
13
114
4.49
57
2.27
8
6
0.24
40
0.09
660
300
35
13
120
4.72
60
2.39
12
6.7
0.26
50
0.11
660
300
35
13
134
5.28
67
2.67
16
8.5
0.33
80
0.18
1320
660
50
13
170
6.69
85
3.38
18
8.9
0.35
82
0.18
1320
660
50
25
178
7.01
89
3.54
24
9.8
0.39
95
0.21
1320
660
50
25
196
7.72
98
3.90
6 Fiber Subunits
24*
13.9
0.55
180
0.40
1320
660
50
25
278
10.94 139
5.53
12 Fiber Subunits
48
18.3
0.72
295
0.65
1320
660
50
25
366
14.41 183
7.28
Single Unit
*Single mode 24fiber cable is subunit Construction only
Part Numbers
LSZH RATED
: DT
RISER RATED : DT
PLENUM RATED: DT
GZ
GR
GP
Transmission Performance
9/125
50/125
Standard
50/125
Gigabit
50/125
10Gigabit
62.5/125
Standard
52.5/125
Gigabit
(1310/1550nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
0.5/0.4
3.0/1.0
3.0/1.0
3.0/1.0
3.5/1.0
3.5/1.0
-
500/500
500/500
1500/500
200/500
200/500
10Gbps
-
-
-
300
-
-
1Gbps
-
-
550/550
-
-
250/550
Attenuation(dB/km) Typical values
Minimum Bandwidth (MHz km)
Ethernet Link Distance (m)
60
LS Fiber Optic Distribution Cable (Indoor)
900um tight buffered Aramid yarn strength member
Description / Applications
Distribution cables are rugged, high performance optical communication
cables for inside plant installations
Backbone & Computer Room Cabling
Compact design for limited conduit space
RoHS (Restriction of the use of Certain Hazardous Substances Directive)
optional
Optical Fiber
0.9mm Buffered Fiber
Aramid Yarn
Sub-unit Jacket
Specification
Ripcord
ISO/IEC 11801
Telcordia GR-409-CORE
ANSI/ ICEA S-83-596
Coated Central
Strenght Member
Options
Fiber - Single mode, 50 , 62.5 multi mode available
Sub-unit & Outer Jacket color
- Single Mode : Yellow
- 62.5/125 1Gbe : Orange
- 50/125 1Gbe : Orange
- 50/125 10Gbe : Aqua
If the cable will be used indoor/outdoor applications, outer cable jacket
shall be black
Outer jacket : PVC or LSZH (Low Smoke Zero Halogen)
Subunit Identification
The identification code & number is printed on the sub-unit jacket every
10 cm (eg. SM#1, SM#2)
Ripcord
Outer Jacket
Sub-Unit Construction
Single Unit Construction
Color of Buffer
01 - Blue
07 - Red
13 - Blue / Black dash
19 - Red / Black dash
02 - Orange
08 - Black
14 - Orange / Black dash
20 - Black / White dash
03 - Green
09 - Yellow
15 - Green / Black dash
21 - Yellow / Black dash
04 - Brown
10 - Violet
16 - Brown / Black dash
22 - Violet / Black dash
05 - Grey
11 - Pink
17 - Grey / Black dash
23 - Pink / Black dash
06 - White
12 - Aqua
18 - White / Black dash
24 - Aqua / Black dash
Mechanical Characteristics
Constuction
/ Operating Temperature : -10 to + 60
Fiber
Count
Nominal
Diameter
Nominal
Weight
Maximum Tensile Load
Short Term Long Term
Crush Load
Short Term
Long Term
Minimum Bend Radius
Loaded
Installed
[mm]
[inch]
[kg/km]
[lb/kft]
[N]
[N]
[N/cm]
[N/cm]
[mm]
[inch] [mm]
[inch]
2
4.5
0.18
20
0.04
660
300
50
25
90
3.54
45
1.79
4
5.3
0.21
25
0.06
660
300
50
25
106
4.17
53
2.11
6
5.7
0.22
30
0.07
660
300
50
25
114
4.49
57
2.27
8
6
0.24
35
0.08
660
300
50
25
120
4.72
60
2.39
12
6.7
0.26
40
0.09
660
300
50
25
134
5.28
67
2.67
16
8.5
0.33
70
0.15
1320
660
100
50
170
6.69
85
3.38
18
8.9
0.35
75
0.17
1320
660
100
50
178
7.01
89
3.54
24
9.8
0.39
90
0.20
1320
660
100
50
196
7.72
98
3.90
6 Fiber Subunits
24*
13.9
0.55
160
0.35
1320
660
100
50
278
10.94 139
5.53
12 Fiber Subunits
48
18.3
0.72
275
0.61
1320
660
100
50
366
14.41 183
7.28
Single Unit
SimpleTM Fiber Solutions
Storage Temperature : -20 to + 70
*Single mode 24fiber cable is subunit Construction only
Part Numbers
LSZH RATED
: DT
RISER RATED : DT
PLENUM RATED: DT
KZ
KR
KP
Transmission Performance
9/125
50/125
Standard
50/125
Gigabit
50/125
10Gigabit
62.5/125
Standard
52.5/125
Gigabit
(1310/1550nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
0.5/0.4
3.0/1.0
3.0/1.0
3.0/1.0
3.5/1.0
3.5/1.0
-
500/500
500/500
1500/500
200/500
200/500
10Gbps
-
-
-
300
-
-
1Gbps
-
-
550/550
-
-
250/550
Attenuation(dB/km) Typical values
Minimum Bandwidth (MHz km)
Ethernet Link Distance (m)
61
LS Fiber Optic Breakout Cable (Indoor)
ONFR(riser rated), OFNP(plenum rated) or LSZH rated
Description / Applications
Breakout cables are rugged, high performance optical communication
cables for inside plant installations
OFNR(riser rated), OFNP(plenum rated) or LSZH (low smoke zero
halogen rated)
Backbone & Computer Room Cabling
Direct Termination on 2.0 mm Sub-Units
RoHS (Restriction of the use of Certain Hazardous Substances Directive)
complied
2.0mm Sub-Unit
Optical Fiber
0.9mm Buffered Fiber
Aramid Yarns
Sub-unit Jacket
Specification
Central Strenght
Member
ISO/IEC 11801
Telcordia GR-409-CORE
ANSI/ ICEA S-83-596
Ripcord
PVC Outer Jacket
Options
Fiber - Single mode, 50 , 62.5 multi mode available
Higher fiber counts available upon request
Other Sub-Unit Diameters Available (1.8mm, 2.4 mm, 2.9mm etc.)
Buffered fiber : Natural (white)
Sub-unit & Outer Jacket color
- Single Mode : Yellow
- 62.5/125 1Gbe : Orange
- 50/125 1Gbe : Orange
- 50/125 10Gbe : Aqua
Subunit Identification
The identification code & number is printed on the sub-unit jacket every
10 cm (eg. 62.5MM#1, 62.5MM#2)
Mechanical Characteristics
Storage Temperature : -20 to + 70
/ Operating Temperature : -10 to + 60
SimpleTM Fiber Solutions
Fiber
Count
Nominal
Diameter
Nominal
Weight
Maximum Tensile Load
Short Term Long Term
Crush Load
Short Term
Long Term
Minimum Bend Radius
Loaded
Installed
[mm]
[inch]
[kg/km]
[lb/kft]
[N]
[N]
[N/cm]
[N/cm]
[mm]
[inch] [mm]
[inch]
2
7.5
0.30
50
0.11
660
300
35
13
150
5.91
75
2.98
4
7.7
0.30
55
0.12
660
300
35
13
154
6.06
77
3.06
6
8
0.31
65
0.14
660
300
35
13
160
6.30
80
3.18
8
9.5
0.37
85
0.19
660
300
35
13
190
7.48
95
3.78
12
10.5
0.41
95
0.21
1320
660
35
13
210
8.27
105
4.18
Part Numbers
LSZH RATED
: BT
RISER RATED : BT
PLENUM RATED: BT
KZ
KR
KP
Transmission Performance
9/125
50/125
Standard
50/125
Gigabit
50/125
10Gigabit
62.5/125
Standard
52.5/125
Gigabit
(1310/1550nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
0.5/0.4
3.0/1.0
3.0/1.0
3.0/1.0
3.5/1.0
3.5/1.0
-
500/500
500/500
1500/500
200/500
200/500
10Gbps
-
-
-
300
-
-
1Gbps
-
-
550/550
-
-
250/550
Attenuation(dB/km) Typical values
Minimum Bandwidth (MHz km)
Ethernet Link Distance (m)
62
LS Fiber Optic Distribution Cable (Indoor)
Micro Distribution Cable
Description
Colored fiber, Micro sub-unit, dielectric strength member, Outer jacket
Micro Sub-unit cable containing Max. 12 optical fibres
Outer sheath: PVC OFNR(riser rated), PVC OFNP(plenum rated) or
LSZH(low smoke zero halogen rated)
RoHS (Restriction of the use of Certain Hazardous Substances Directive)
complied
Optical Fiber
Color of Fiber
Micro Sub-Unit
01 - Blue
05 - Grey
09 - Yellow
02 - Orange
06 - White
10 - Violet
03 - Green
07 - Red
11 - Pink
04 - Brown
08 - Black
12 - Aqua
Dielectric Strenfth
Member
Outer Jacket
Color of Micro Sub-unit
Natural or white
Color of Sheath
SM-Yellow
MM-Orange
Mechanical Characteristics
/ Operating Temperature : -10 to + 60
Fiber
Count
Nominal
Diameter
Nominal
Weight
Maximum Tensile Load
Short Term Long Term
Crush Load
Short Term
Long Term
Minimum Bend Radius
Loaded
Installed
[mm]
[inch]
[kg/km]
[lb/kft]
[N]
[N]
[N/cm]
[N/cm]
[mm]
[inch] [mm]
[inch]
2
3.8
0.15
15
0.03
300
100
7.4
3.7
76
2.99
38
1.51
4
3.8
0.15
15
0.03
300
100
7.4
3.7
76
2.99
38
1.51
6
3.8
0.15
15
0.03
300
100
7.4
3.7
76
2.99
38
1.51
8
3.8
0.15
15
0.03
300
100
7.4
3.7
76
2.99
38
1.51
12
3.8
0.15
15
0.03
300
100
7.4
3.7
76
2.99
38
1.51
Part Numbers
LSZH RATED
: MD
RISER RATED : MD
PLENUM RATED: MD
SimpleTM Fiber Solutions
Storage Temperature : -20 to + 70
KZ
KR
KP
Transmission Performance
9/125
50/125
Standard
50/125
Gigabit
50/125
10Gigabit
62.5/125
Standard
52.5/125
Gigabit
(1310/1550nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
(850/1300nm)
0.5/0.4
3.0/1.0
3.0/1.0
3.0/1.0
3.5/1.0
3.5/1.0
-
500/500
500/500
1500/500
200/500
200/500
10Gbps
-
-
-
300
-
-
1Gbps
-
-
550/550
-
-
250/550
Attenuation(dB/km) Typical values
Minimum Bandwidth (MHz km)
Ethernet Link Distance (m)
63
LS Fiber Optic Multi Loose Tube Cable (Outdoor)
All Dielectric Single Jacket Non-Armor Loose Tube Cable
Description / Applications
All dielectric Single Jacket Multi Loose Tube cable is a UV-stabilized, fully
water blocked cable for In/Outdoor duct applications.
Loose tube design provides stable and highly reliable transmission
parameters for a variety of voice, data, video and imaging applications.
This lightweight cable offers durability and flexibility required for many
outside plant uses.
RoHS (Restriction of the use of Certain Hazardous Substances Directive)
Complied
Optical Fiber
Filling Compound
Loose Buffer Tubes
Core Wrapping Tape
Specification
Black PE/LSZH Jakcet
Telcordia GR-20-CORE
IEC 60793 / IEC 60794
IEC 60332-1,3
IEEE 383
Water Blocking Yarn or Jelly
Outer Strength Member
Ripcord
Color Identification
Central Strength Member
01 - Blue
05 - Slate
09 - Yellow
02 - Orange
06 - White
10 - Violet
03 - Green
07 - Red
11 - Pink
04 - Brown
08 - Black
12 - Aqua
36-Fiber Cable
Mechanical Characteristics
Storage Temperature : -40 to + 70
SimpleTM Fiber Solutions
Fiber
Count
/ Operating Temperature : -40 to + 70
Nominal*
LS C&S Part Number Outer diameter
[mm]
[inch]
Nominal*
Weight
[kg/km] [lb/1000 ft]
Maximum Tensile Load
Crush Load
Short Term Long Term Short Term Long Term
[N]
[lb]
[N]
[lb]
[N/cm] [Ib/inch] [N/cm] [Ib/inch]
Minimum Bend Radius
Loaded
Installed
[cm]
[inch]
[cm]
[inch]
6
LT-DJB
/
/
-06 10.5/11.2 0.41/0.44 86/115 58/77
2,700 125 1,000 46
110
63
55
31
21/22.4 8.27/8.82 10.5/11.2 4.13/4.41
12
LT-DJB
/
/
-12 10.5/11.2 0.41/0.44 86/115 58/77
2,700 125 1,000 46
110
63
55
31
21/22.4 8.27/8.82 10.5/11.2 4.13/4.41
24
LT-DJB
/
/
-24 10.5/11.2 0.41/0.44 86/115 58/77
2,700 125 1,000 46
110
63
55
31
21/22.4 8.27/8.82 10.5/11.2 4.13/4.41
36
LT-DJB
/
/
-36 10.5/11.2 0.41/0.44 86/115 58/77
2,700 125 1,000 46
110
63
55
31
21/22.4 8.27/8.82 10.5/11.2 4.13/4.41
48
LT-DJB
/
/
-48 11.0/11.7 0.43/0.46 92/130 62/87
2,700 125 1,000 46
110
63
55
31
22/23.4 8.66/9.21 11.0/11.7 4.33/4.61
72
LT-DJB
/
/
-72 11.0/11.7 0.43/0.46 92/130 62/87
2,700 125 1,000 46
110
63
55
31
22/23.4 8.66/9.21 11.0/11.7 4.33/4.61
96
LT-DJB
/
/
-96 12.1/13.7 0.48/0.54 113/167 76/112
2,700 125 1,000 46
110
63
55
31
24/27.4 9.53/10.79 12.1/13.7 4.76/5.39
120
LT-DJB
/
/
-120
13.6
0.54
139
93
2,700 125 1,000 46
110
63
55
31
27
10.71
13.6
144
LT-DJB
/
/
-144
15.0
0.59
167
112
2,700 125 1,000 46
110
63
55
31
30
11.81
15
5.9
228
LT-DJB
/
/
-228
15.8
0.62
178
120
2,700 125 1,000 46
110
63
55
31
32
12.44
15.8
6.22
276
LT-DJB
/
/
-276
17.0
0.67
212
142
2,700 125 1,000 46
110
63
55
31
34
13.39
17
6.69
300
LT-DJB
/
/
-300
17.7
0.70
228
153
2,700 125 1,000 46
110
63
55
31
35
13.94
17.7
6.97
5.35
*denotes norminal value for PE / LSZH Jacketed Cable.
Part Numbers
LT-DJB
Shipping Information
Standard Reel Length
4000m
*Other Cable lengths may be available upon request
64
/
/
-
LS Fiber Optic Multi Loose Tube Cable
(Outdoor)
All Dielectric Single Jacketed Multi Loose Tube with Polyamide Sheath for Insect-resistant
Description / Applications
All dielectric Single Jacket Multi Loose Tube cable is a UV-stabilized, fully
water blocked cable for outdoor duct applications.
Polyamide sheath construction provides resistance against insects.
Loose tube design provides stable and highly reliable transmission
parameters for a variety of voice, data, video and imaging applications.
This lightweight cable offers durability and flexibility required for many
outside plant uses.
Optical Fiber
Filling Compound
Loose Buffer Tubes
Specification
Plastic Core Wrapping Tape
Telcordia GR-20-CORE
IEC 60793 / IEC 60794
ITU-T G652
PE Jakcet
Filling Compound
Color Identification
Polyamide Sheath
01 - Blue
05 - Slate
09 - Yellow
02 - Orange
06 - White
10 - Violet
03 - Green
07 - Red
11 - Pink
04 - Brown
08 - Black
12 - Aqua
FRP Strength Member
48-Fiber Cable
Mechanical Characteristics
Fiber
Fiber
Count
Count
/ Operating Temperature : -30 to + 70
Nominal*
Nominal*
LS C&S Part NumberOuter
Outer
diameter
diameter
[mm] [inch]
[inch]
[mm]
Nominal*
Nominal*
Weight
Weight
Maximum
Tensile
Load
Maximum
Tensile
Load
Short
Term Long
Long
Term
Short
Term
Term
[kg/km][lb/1000
[lb/1000
[kg/km]
ft] ft] [N][N] [lb][lb]
[N][N] [lb][lb]
Crush
Load
Minimum
Bend
Radius
Crush
Load
Minimum
Bend
Radius
Short
Term Long
Long
Term Loaded
Loaded Installed
Installed
Short
Term
Term
[N/cm]
[Ib/inch][N/cm]
[N/cm]
[Ib/inch] [cm]
[cm][inch]
[inch] [cm]
[cm][inch]
[inch]
[N/cm]
[Ib/inch]
[Ib/inch]
4
LT
SJNA04-N
10.5
0.41
115
77
2,000 93
900
42
220
125
110
63
21.0 8.27
10.5 4.13
8
LT
SJNA08-N
10.5
0.41
115
77
2,000 93
900
42
220
125
110
63
21.0 8.27
10.5 4.13
16
LT
SJNA16-N
10.5
0.41
115
77
2,000 93
900
42
220
125
110
63
21.0 8.27
10.5 4.13
24
LT
SJNA24-N
10.5
0.41
115
77
2,000 93
900
42
220
125
110
63
21.0 8.27
10.5 4.13
32
LT
SJNA32-N
10.5
0.41
115
77
2,000 93
900
42
220
125
110
63
21.0 8.27
10.5 4.13
48
LT
SJNA48-N
10.5
0.41
115
77
2,000 93
900
42
220
125
110
63
21.0 8.27
10.5 4.13
Part Numbers
LT
SJNA
SimpleTM Fiber Solutions
Storage Temperature : -40 to + 80
-N
Shipping Information
Standard Reel Length
4000m
*Other Cable lengths may be available upon request
65
Optical Fiber Distribution / Adaptor & Connector
Optical Fiber Distribution
Part Numbers
Description
FDF LC 19” Rack (Fiber Adaptors Outer Type)
Part Number
LS-FDF-WW-XX-YYY-ZZ
FDF LC 19” Rack (Fiber Adaptors Inner Type)
LS-FDF-WW-XX-YYY-ZZ-I
FDF LC 19” Rack (Swing Type)
LS-FDF-WW-XX-YYY-ZZ-S
SimpleTM Fiber Solutions
WW denotes SC,LC or ST etc / XX denotes SM(Single Mode) or MM(Multi Mode)
YYY denotes number of core / ZZ denotes SP(Simplex) or DP(Duplex)
Adaptor & Connector
Part Numbers
Description
LC Adaptor
LS-FA-LC-XX-Y-ZZ
SC Adaptor
LS-FA-SC-XX-Y-ZZ
ST Adaptor
LS-FA-ST-XX-Y-ZZ
LC Connector
LS-FC-LC-XX-Y-ZZ
SC Connector
LS-FC-SC-XX-Y-ZZ
ST Connector
LS-FC-ST-XX-Y-ZZ
XX denotes SM (Single Mode) or MM (Multi Mode)
Y denotes 1 or 2 Core
ZZ denotes Color : BL (Blue)-SM/PC, BG (Beige)-MM/PC, GN (Green)-SM/APC
66
Part Number
LS Fiber Distribution Frame
with Module Panel & Gland
Description
These Patch panels come complete with fiber cable wire management, Tray, accessories and full installation
instructions. They fully comply with the requirements set out in TIA 19” Rack type. This holds the FDP(FDF
Adaptor Panel) items.
Part Numbers
Part Number
Description
FDF without module panel
LS-FDF-EP-XX-YYY-A
XX Denotes U : 1U, 2U, 4U, 8U
YYY Denotes number of tray :E24(24core), E48(48Core), E72(P2Core), E96(96Core)
Part Numbers
FDF module panel (SC type)
LS-FDF-SC-XX-YYY-A
FDF module panel (LC type)
LS-FDF-LC-XX-YYY-A
FDF module panel (ST type)
LS-FDF-ST-XX-YYY-A
FDF Blank Panel
SimpleTM Fiber Solutions
Part Number
Description
LS-FDF-BK-A
XX denotes SM (Single Mode) or MM (Multi Mode)
YYY denotes the Number of Cores
Description
These Glands are used as fiber cable holder in rear side of FDF.
Part Numbers
Description
Part Number
LS-GLAND-D7
FDF Gland
7
FDF Gland
9
LS-GLAND-D9
FDF Gland
11
LS-GLAND-D11
FDF Gland
13.5
FDF Gland
16
LS-GLAND-D13.5
LS-GLAND-D16
67
LS-SC Field Installable Optical Connector
Description
Key Features
Easy installation in the field without
adhesive & polishing
Easy operation & Quick assembly
Compatible with conventional SC connector
Neither adhesive nor polishing necessary
Performance exceeds ANSI/TIA/EIA-568-A
Additional tool does not necessary
Telcordia GR-1081-CORE
Can be installed to 0.25mm,0.9mm and 3.0mm cord
Connector & fiber re-use available
Specification
Item
PCA
SM(1310/1550nm)
MM(850/1310nm)
Insertion Loss
(against master plug)
Max. 0.5dB
Max. 0.5dB
Max. 0.5dB
45
50
60
Return Loss
10N
Cable retention
Application cable diameter
0.25mm fiber, 0.9mm tight buffer,
SimpleTM Fiber Solutions
3.0mm cord or cable, 2.0mm Flat type cable
Standard
IEC61754-4
GR-1081-CORE
Operation Temperature
-40
~ 70
APC : 3.5 angled cleaving
Part Numbers
Part Numbers
Description
Fiber Optic Field Installable connector SC Type
FOSC-SC-WW-XXX-YY-ZZ
Fiber Optic Field Installable connector LC Type
FOSC-LC-WW-XXX-YY-ZZ
WW denotes polishing - PC : Physical Contact (SPC, UPC)
A5 : Angled Physical Contact (Return loss
A6 : Angled Physical Contact (Return loss
XXX denotes using cable diameter - 025
(Boot inner size)
090
XXX denotes using cable diameter - 200
XXX denotes using cable diameter - 300
:
:
:
:
0.25mm Coated Fiber
0.9mm Tight Buffer
2.0mm Flat
3.0mm cord
YY denotes housing color - BL : SM PC type (Blue)
YY denotes housing color - GN : SM APC type (Green)
YY denotes housing color - BG : MM PC type (Beige)
ZZ denotes boot color - BL : Blue,
ZZ denotes boot color - BK : Black,
68
RD : RED,
BG : Beige,
GN : Green
GY : Grey
50)
60)
Installation Manual for Field Installable
Optical Connector
LS-SC Assembly Procedure
2. Stripping coating around 20mm
3. Inserting cord after cleaning alcohol and fiber cutting(10mm) using tool
4. Inserting connector to Assembly
tool
5. Inserting cable(fiber) until
bending occurs(important)
SimpleTM Fiber Solutions
1. Boot insert in cable as above
picture
6. Push push-holder toward front
8. Inserting boot & housing
7-1. Connect Ez-Sc to patch cord and beamig light (SUCCESS)
7-2. Connect Ez-Sc to patch cord and beamig light (FAILUER)
9. Connection completed
69
Fiber Optic Jumper Cord & Fiber Optic Pigtail
Description
Pull Proof
Very easy to Connect or Disconnect
Low Insertion loss / Low Back Reflection
Small & High Density
Stable, Reliable, Excellent in severe Environment
Application
Telecommunication networks
Data Processing Systems
Instrumentation
CATV
LANs and WANs
Fiber Optic Test & Measurement System
Part Numbers
Part Number
SimpleTM Fiber Solutions
Description
Fiber Optic Jumper Cord
LS-JC-A/B-C-D-E (-F-G-H)
Fiber Optic Pigtail
LS-PIG-A-C-D-E (-F-G-H)
A/B Denotes Connector type : SC, FC, ST, LC, MU, MTRJ, E2000 etc.
C Denotes Fiber type : SM, MM1(OM1), MM2(OM2), MM3(OM3)
D Denotes Cable type : SP (Simplex Cord), DP (Duplex Cord)
E Denotes Meter : 005(0.5m), 010(1m), 050(5m), 100(10m) etc.
* Option
F Denotes Boot color : BL (Blue), RD (Red), GN (Green), GY (Grey) - (*Unmarked type is as standard)
G Denotes Polishing : PC, UPC, APC (*Unmarked type is PC)
H Denotes Cable Outer Diameter : 0.9( 0.9), 2.0( 2.0), 3.0( 3.0) - (*Unmarked type is 0.9)
General Specification
Fiber Type
Polishing Type
PC
UPC
APC
0.3dB
Insertion Loss
Return Loss
MM(850/1310nm)
SM(1310/1550nm)
40dB
55dB
60dB
Note : PC (Physical Contact), UPC (Ultra Physical Contact), APC (Angled Physical Contact)
70
PC
0.5dB
30dB
FTTx System
Switching Hub Series
SimpleTM Multiplexer
FTTx System
Optical Switching Hub
Description
Max transmission speed: 100 Mbps
Compliant with IEEE802.3 10/100Base-TX
Stable switching hub module
and 100Base-FX
Telecommunication distribution equipment
Link test ports: 2 ports (Link-In/Link-Out)
for the integrated IT sites
DIP switch adopted for outside line,
8 and 16 data ports
accommodating four outside lines, which can be added
Optical 100Base-FX 2 ports
Power fuse adopted, which prevents overcurrent
10/100 Mbps switching hub
Lightning protection for outside lines
Frontal connection access
24 ports for voice and four outside lines
Auto reset in case of power emergency
Voice support in case of black out
Application
Ultra high speed broadband top grade service
Cyber (fiber) apartment application
FTTH, FTTO, FTTC
Technical Details
Class
Data Port
206.0
182.0
국선±3
국선±4
국선/DATA
INPUT
국선±2
DATA
OUT
TEST
±?º±1
2X
3X
4X
5X
6X
7X
-
IEEE802.3 / 802.3U Swap
-
Half-Duplex : Back Pressure Flow Control
-
Full-Duplex : IEEE802.3x Flow Control
-
Broadcast Storming Filter Function
-
1024 MAC Address
-
Auto Negotiation (10/100 Mbps Auto Sensor)
-
Auto MDI-X Function (Plug-and-Play Cable)
-
Auto Polarity (Cable +/- Auto Sensor)
-
Auto Power Reset (Auto-Reset)
-
Remarks
8X
3A
1X
FX
RST
PWR
DC 5V
158.4
Unit
Characteristics
10/100Mbps Switching Hub
9X
10X
11X
12X
13X
14X
15X
16X
LS-MF-FX16
FX
TX
RX
LED Display (Power / Link / Act)
Optical Port
Optical : Input 1310
10 / Output 1310
10
Nm
Level : Input -31dBm ~ -14dBm / Output -19dBm ~ -14dBm
dBm
SimpleTM Multiplexer
Optical Cable : Multimode
Connector : SC-PC
Voice Port
Max 4 outside lines (EIA/TIA 568A and 568B compliant)
Outside line 1: 14 voice ports; Outside line 2: 4 voice ports;
Outside line 3: 3 voice ports; Outside line 4: 2 voice ports
Voice support in case of black out
Test Port
Cat. 5e linkage support
RJ45 Type containing 1 to 1 serial port
Port
RJ45 4P8C Modular Jack
Power
Input AC220 / Output DC 12/500
Temperature
-10 ~ 70 / 14 ~ 158
V , V/mA
/
Part Numbers
Description
Dimension
Part Number
(L x W x H) (mm)
72
LS-MF-FX16
FTTx Switch Hub 16 Port
158 x 182 x 15
FTTx Switch Hub 8 Port
129 x 169 x 47
LS-MF-FX08
FDF SC Type (4Port)
158 x 182 x 19
LS-FDF-SC-MM-4(FTTx)
Switching Hub Series
Switching Hub
Description
Max transmission speed: 100 Mbps
Compliant with IEEE802.3 10/100Base-TX
Stable switching hub module
and 100Base-FX
Telecommunication distribution equipment
Link test ports: 2 ports (Link-In/Link-Out)
for the integrated IT sites
DIP switch adopted for outside line,
8 and 16 data ports
accommodating four outside lines, which can be added
10/100 Mbps switching hub
Power fuse adopted, which prevents overcurrent
Frontal connection access
Lightning protection for outside lines
Auto reset in case of power emergency
24 ports for voice and four outside lines
Voice support in case of black out
Application
Ultra high speed broadband first grade service
Technical Details
Class
Data Port
국선±3
3X
4X
5X
6X
7X
8X
DC 5V
RST
PWR
2X
-
IEEE802.3 / 802.3U
-
Half-Duplex : Back Pressure Flow Control
-
Full-Duplex : IEEE802.3x Flow Control
-
Broadcast Storming Filter Function
-
1024 MAC Address
-
Auto Negotiation (10/100Mbps Auto sensor)
-
Auto Polarity (Cable +/- Auto recognition)
-
Auto Power Reset (Automatic Recovery Under Power Shortage)
-
LED Display (Power / Link / Act)
-
Max 4 outside lines (EIA/TIA 568A and 568B compliant)
-
Outside line 1: 14 voice ports; Outside line 2: 4 voice ports;
-
2A
국선/DATA
INPUT
국선±4
±?º±1
1X
10/100Mbps Switching Hub
128.6
LS-SH-D8
Voice Port
Outside line 3: 3 voice ports; Outside line 4: 2 voice ports
Voice support in case of black out
Test Port
Cat. 5e linkage support
RJ45 Type containing 1 to 1 serial port
Port
RJ45 4P8C Modular Jack
Power
Input AC220 / Output DC 5V/2A
Temperature
-10 ~ 70 / 14 ~158
SimpleTM Multiplexer
국선±2
Unit
TEST
DATA
OUT
169.3
Characteristics
V , V/mA
/
Part Numbers
Description
Dimension
Part Number
(L x W x H) (mm)
Ethernet Switch Hub 16 Port
158 x 182 x 15
LS-SH-D16
Ethernet Switch Hub 8 Port
129 x 169 x 47
LS-SH-D08
73
ECX Series 75
Coaxial Cable
RG Series6 Coaxial Cable
RG Series6/11 Coaxial Cable
HFBT Series Coaxial Cable
SimpleTM CATV Cable
ECX Series 75
2nd Outer Conductor
Inner Conductor
Outer Jacket
Description / Applications
Bare Copper Conductor
Solid Polyethylene Dielectric
Bare Copper Braid
Black PVC Jacket
Characteristics
Material
Characteristics
3C-2V
5C-2V
7C-2V
10C-2V
mm (inch)
mm (inch)
mm (inch)
mm (inch)
Inner Conductor
Bare Copper
0.40 (0.016)
0.80 (0.031)
7/0.40 (7/0.016)
7/0.50 (7/0.020)
Dielectric
Solid PE
2.40 (0.094)
4.90 (0.193)
7.30 (0.287)
9.40 (0.370)
-
-
-
-
3.00 (0.118)
5.60 (0.220)
8.20 (0.323)
10.40 (0.409)
1st Outer Conductor
2nd Outer Conductor
Copper Braid
3rd Outer Conductor
-
-
-
-
-
4th Outer Conductor
-
-
-
-
-
Floodant
Jacket
PVC
-
-
-
-
4.00 (0.157)
7.40 (0.291)
10.40 (0.409)
13.00 (0.512)
Electrical Specifications
Characteristic Impedance ( )
75 3
75 3
75 3
75 3
Velocity of Propagation (%)
66
66
66
66
Capacitance, Nominal (pF/m)
67
67
67
67
DC Resistannce ( / km) - Inner Conductor
91.40
35.90
20.70
13.10
2.20
1.80
Attenuation
[email protected]
Frequency (MHz)
SimpleTM CATV Cable
Dielectric
Coaxial Cable
dB/100m
10
4.20
2.70
75
RG Series6 Coaxial Cable
Dielectric
Inner Conductor
2nd Outer Conductor
1st Outer Conductor
3rd Outer Conductor
Outer Jacket
Description / Applications
Copper Covered Steel Conductor
Foamed Polyethylene Dielectric
Bonded AP Laminate Tape Shield
56% Aluminum Braid
AP Laminate Tape Shield
Black PVC Jacket
Characteristics
5C
Material
Characteristics
mm (inch)
Inner Conductor
Copper Covered Steel
1.02 (0.0403)
Dielectric
Foamed Polyethylene
4.57 (0.18)
1st Outer Conductor
Sealed APA Tape
4.70 (0.185)
2nd Outer Conductor
56% Aluminum Braid
5.30 (0.209)
3rd Outer Conductor
Unsealed AP Tape
5.45 (0.215)
4th Outer Conductor
-
-
Floodant
-
-
PVC
6.95 (0.274)
Jacket
Electrical Specifications
Characteristic Impedance ( )
Velocity of Propagation (%)
Capacitance, Nominal (pF/m)
DC Resistannce ( / km) - Inner Conductor
SimpleTM CATV Cable
Attenuation,
85
53.2
100
[email protected]
Frequency (MHz)
76
75 3
dB/100m
10
2.38
50
4.72
150
7.72
250
9.89
350
11.71
450
13.70
750
17.80
864
19.50
1000
21.53
RG Series6/11 Coaxial Cable
1st Outer Conductor
Dielectric
3rd Outer Conductor
2nd Outer Conductor
4th Outer Conductor
Jacket
Description / Applications
Copper Covered Steel Conductor
Bonded AP Laminate Tape Shield
APA Laminate Tape Shield
Foamed Polyethylene Dielectric
Aluminum Braid
Black PVC Jacket
Characteristics
Standard
Material
Characteristics
Trishield
Quadshield
Series6
Series11
Series6
Series11
Series6
Series11
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
Inner Conductor
Copper Covered Steel
Dielectric
Foamed Polyethylene
4.57 (0.180)
7.11 (0.280)
4.57 (0.180)
7.11 (0.280)
4.57 (0.180)
7.11 (0.280)
1st Outer Conductor
Sealed APA Tape
4.70 (0.185)
7.32 (0.288)
4.70 (0.185)
7.32 (0.288)
4.70 (0.185)
7.32 (0.288)
2nd Outer Conductor
Aluminum Braid
5.30 (0.209)
7.92 (0.312)
5.30 (0.209)
7.92 (0.312)
5.30 (0.209)
7.92 (0.312)
60
60
60/40
60
60
60/40
5.45 (0.215)
8.03 (0.316)
5.45 (0.215)
5.45 (0.215)
Coverage (%)
3rd Outer Conductor
Unsealed APA Tape
4th Outer Conductor
Jacket
1.02 (0.0403) 1.63 (0.0641) 1.02 (0.0403) 1.63 (0.0641) 1.02 (0.0403) 1.63 (0.0641)
PVC
-
-
-
-
6.12 (0.241)
8.66 (0.341)
6.95 (0.274) 10.20 (0.400) 7.06 (0.278) 10.20 (0.400) 7.54 (0.297)
-
-
10.30 (0.407)
Electrical Specifications
Standard
Series6
Characteristic Impedance ( )
Velocity of Propagation (%)
Capacitance, Nominal (pF/m)
DC Resistannce ( / km) - Inner Conductor
40.0
- Outer Conductor
Trishield
Series11
Quadshield
Series11
Series6
Series11
75 3
75 3
85
85
85
53.2
53.2
53.2
100.00
30.00
Series6
40.0 100.00
24.00
Attenuation,
21.00
75 3
40.0 100.00
15.00
16.00
12.00
[email protected]
Frequency (MHz)
dB/100m
5
2.66
1.25
2.66
1.25
2.66
1.25
55
5.25
3.38
5.25
3.38
5.25
3.38
211
10.10
6.59
10.10
6.59
10.10
6.59
250
11.02
11.48
7.22
7.55
11.02
11.48
7.22
7.55
11.02
11.48
7.22
7.55
270
300
12.14
7.97
12.14
7.97
12.14
7.97
330
12.76
8.37
12.76
8.37
12.76
8.37
350
13.16
8.66
13.16
8.66
13.16
8.66
400
14.11
9.28
14.11
9.28
14.11
9.28
450
15.88
9.91
15.88
9.91
15.88
9.91
500
15.88
10.47
15.88
10.47
15.88
10.47
550
16.70
11.02
16.70
11.02
16.70
11.02
600
17.52
11.61
17.52
11.61
17.52
11.61
750
19.69
13.09
19.69
13.09
19.69
13.09
870
21.33
14.21
21.33
14.21
21.33
14.21
1000
22.97
15.32
22.97
15.32
22.97
15.32
SimpleTM CATV Cable
Inner Conductor
77
HFBT Series Coaxial Cable
5C, 7C, 10C
Dielectric
Inner Conductor
2nd Outer Conductor
1st Outer Conductor
3rd Outer Conductor
Outer Jacket
Description / Applications
Bare Copper Conductor
Foamed Polyethylene Dielectric
Non-Bonded APA Laminate Shield
60% Tinned Copper Braid
AP Laminate Shield
Black PVC Jacket
Characteristics
Material
Characteristics
5C
7C
10C
mm (inch)
mm (inch)
mm (inch)
Inner Conductor
Bare Copper
1.20 (0.0470)
1.80 (0.071)
2.40 (0.094)
Dielectric
Foamed Polyethylene
5.00 (0.197)
7.30 (0.287)
9.40 (0.37)
1st Outer Conductor
Unsealed APA Tape
5.10 (0.201)
7.40 (0.291)
9.50 (0.374)
2nd Outer Conductor
60% Tinned Copper Braid
5.60 (0.22)
7.95 (0.313)
10.05 (0.395)
3rd Outer Conductor
Unsealed AP Tape
5.65 (0.222)
8.00 (0.315)
10.10 (0.398)
4th Outer Conductor
-
-
-
Floodant
-
-
-
-
PVC
7.40 (0.291)
10.00 (0.394)
12.30 (0.484)
Jacket
-
Electrical Specifications
Characteristic Impedance ( )
Velocity of Propagation (%)
Capacitance, Nominal (pF/m)
DC Resistannce ( / km) - Inner Conductor
SimpleTM CATV Cable
Attenuation,
85
53.2
16.6
[email protected]
Frequency (MHz)
78
75 3
dB/100m
10
2.38
50
4.72
150
7.72
250
9.89
350
11.71
450
13.70
750
17.80
864
19.50
1000
21.53
Cabinet Rack
Open Rack
Rack Accessory
Overhead Routing System
SimpleTM Rack & Cable Management
Cabinet Rack
Description & Application
All standard 19 cabinets generally conform to (IEC297-Part1,2,3), (EIA RS-310-C), (DIN 41494 100) 19 standard. LS
SimpleTM Cabinet Rack provides unsurpassed strength, stability and durability for supporting FDF, patch panels, highdensity blocks, cabling and other telecommunication equipment.
Light Weight
Material : 6063-T5 Aluminum Construction - 5.0T safety glass front door / slide latch type side door / 1.2T
steel rear door / side, rear cable bracket / ground bar / caster and level foot
Finish : Ivory Powder Coat
Dimension
Dimension (H x D x W ), mm
No.
Part Number
H
U
D
W
1
1,000
18
750
600 (19 )
LS-CR-1000
2
1,200
22
750
600 (19 )
LS-CR-1200
3
1,400
27
750
600 (19 )
LS-CR-1400
4
1,600
31
750
600 (19 )
LS-CR-1600
5
1,800
36
750
600 (19 )
LS-CR-1800
6
2,000
40
750
600 (19 )
LS-CR-2000
7
2,200
45
750
600 (19 )
LS-CR-2200
Configuration
D
Top View
Rack & Cable Management
H
W
Simple
TM
Front (Inner) View
80
Front View
Side View
Rear View
Open Rack
Description & Application
All standard 19” rack generally conform to (IEC297-Part1,2,3), (EIA RS-310-C), (DIN 41494 100) 19”
Standard. LS Simple™ Data Open Rack provides unsurpassed strength, stability and durability for supporting
FDF, patch panels, high-density blocks, telecommunication equipment and data center cabling. Available
various accessories.
Light Weight
Material : 6063-T5 Aluminum Construction / 3.0T insulated plate / ground bar / 1.0T END Cover
Options
Upper tray / Finger Kit / Spool Kit
Finish : Black Powder Coat
Dimension
Dimension (H x D x W), mm
No. Description
Part Number
H
U
D
W
1
Open Rack
1,800
36
360
31
LS-OR-1800
2
Open Rack
2,000
41
360
35
LS-OR-2000
3
Open Rack
2,200
46
360
40
LS-OR-2200
4
Spool Kit
1,800 ~ 2,200
-
-
-
LS-OR-SK-XXXX
5
D-ring Kit
1,800 ~ 2,200
-
-
-
LS-OR-DK-XXXX
6
Finger Kit
1,800 ~ 2,200
-
-
-
LS-OR-FK-XXXX
* XXXX denotes H (height) : 1800 ~ 2200
Simple
TM
Rack & Cable Management
Configuration
81
Rack Accessory
Entry Panel
19 , 1U (2Hole, 4Hole)
Jumper Trough Panel
19 Rack Type
Blank Panel (1, 2, 3, 4, 5, 6U)
110 Block Panel
19 Rack Type (2U, 4U, 6U)
Rear Cable Bracket(Aluminium)
Rear Cable Arrangement(Steel)
Surge Protector BRT
19 , 23 Rack Type
Organizer Panel
19 23 Rack Type (1U, 2U)
Wire Cable Bracket
19 Rack Type 1U
D-ring Cable Arrange
Spool Cable Arrange
Finger Bracket Cable Arrange
Ringrun Panel
19 , 23 Rack Type (1U, 2U)
Organizer Panel
19 23 Rack Type (1U, 2U)
Wire Cable Bracket
19 Rack Type 1U
Rack Supporter
Open Rack Supporter
Min. 600 ~ Max. 1200 mm
Plinth
Open Rack Plinth
(H200, 250, 300 mm)
Power Strip
(4,6,8,10,14,20 outlets)
15A, 110/220V
Simple
TM
Rack & Cable Management
Ringrun Panel
19 , 23 Rack Type (1U, 2U)
82
Overhead Routing System
Description & Application
Non-Toxic Material
UV resistant material
(RoHS, Halogen-Free)
Speedy installation-save time & manpower
VO Flame retardant-UL 94
Effective protection for fiber optic cables inside
Reliable Strength
No need special tools for installation
Provide Various Size
Accommodate various raceway applications
Dimension
Description
Dimension (W x H)
Part Number
Main duct
300mm X 100mm
220mm X 100mm
160mm X 100mm
100mm X 100mm
50mm X 50mm
LS-DS-MD-XX-YY
Horizontal Elbow 45°
Cross
Joiners
LS-DS-HA-XX-YY
LS-DS-CA-XX-YY
LS-DS-JI-XX-YY
XX Denotes Size of Width : 05(50mm), 10(100mm), 16(160mm), 22(220mm), 30(300mm)
YY Denotes Color : YL(Yellow/Fiber), GY(Grey/Copper)
Standard length (Main duct) : 2m
Simple
TM
Rack & Cable Management
Installation
83
Overhead Routing System
Dimension
Description
Dimension (W x H)
Vertical Elbow 45° Down
Vertical Elbow 45° Up
Top Outlet Drop
Outlet Trumpet
300mm X 100mm
220mm X 100mm
160mm X 100mm
100mm X 100mm
50mm X 50mm
Reducers
100mm X 100mm
50mm X 100mm
Step down
XX Denotes Size of Width : 05(50mm), 10(100mm), 16(160mm), 22(220mm), 30(300mm)
YY Denotes Color : YL(Yellow/Fiber), GY(Grey/Copper)
‘Reducers’ Part Number at XX (W) : 30 (300mm 220mm), 22 (220mm 160mm), 16 (160mm
Installation
Simple
TM
Rack & Cable Management
Configuration
84
LS-DS-DA-XX-YY
LS-DS-UA-XX-YY
LS-DS-DR-XX-YY
LS-DS-TP-XX-YY
LS-DS-MB-XX-YY
Mounting Bracket Kit
Side Drop Mounting
Bracke
Part Number
LS-DS-TA-XX-YY
Tee
LS-DS-SMB-XX-YY
LS-DS-RD-XX-YY
100mm), 10 (100mm
50mm)
SimpleTM Intelligent Power Management Solutions
Intelligent Power Management Solutions
Monitoring Unit
Intelligent Power Distribution Unit (i-PDU)
Remote Monitoring Link Box
Sensors
Intelligent Power Management Software
CL-Amp Kit Solution
SimpleTM Intelligent Power Management Solutions
Intelligent Power Management
One of the major concerns facing data centre planning & implementation is providing and controlling sufficient power. Technology, such as blade
servers, require greater capacity, which also has an impact on ensuring continuity of supply. Add to this, the escalating cost of energy, and the
requirement to have management information and control becomes ever more critical.
Why should you monitor (and manage) power?
•Monitoring power usage
•Trending analyses
•Control of power, reducing wasted power
•Create a detailed picture of interdependent factors
•Early warning
•Enables automation
•Increase ROI
•Reduce risk
•Capacity and heat location Planning
•Phase balancing
•Remote rebooting / switching
A reliable and robust power supply to the network environment has to address:
•Adequate capacity for existing & future needs
•Monitoring, measuring & reporting power usage via multiple clients
•Billing stream capability for hosted clients
•Unauthorised use of power outlets / equipment deployment
•System load management (phase balancing, capacity planning etc)
•Recovery of locked servers via remote IP power cycling
•Alarming & trending of system/rack/PDU/outlet level overload conditions
•Status information can be gathered locally or remotely via secure authenticated IP
access (LDAP) with RMS voltage, amps & kWh being easily visible or trended and
displayed graphically.
86
SimpleTM Intelligent
Intelligent
Power Management
Power Management Solutions
Intelligent Power Management
In addition to monitoring power, the need for environmental monitoring & control give today’s modern data centre an environment that is monitored
and controlled accurately, as stable environmental conditions are vital to ensure reliable and constant operation.
With environmental failures being one of the major causes of unplanned downtime and data loss, IT professionals responsible for delivering high
availability networks are becoming increasingly aware of the need to protect networks at the physical level, i.e. the very environment that houses
their computer equipment.
Areas of primary concern to the data centre and computer room manager are:
•temperature
•power
•access control
Temperature control is often top of the list, as all equipment has an optimum operating range and damage caused by exceeding this may invalidate
manufacturers’ warranties. The increase in data centre hot-spots has only exacerbated this problem, with increased power loads within the rack
enclosures raising temperatures.
UPS, HVAC, fans and motion sensors can also be monitored remotely with an integrated system - thus from the micro-environment within the rack to
the data centre or computer room in general, all aspects can be integrated & controlled with the high level of flexibility demanded by such a complex
environment.
Benefits of IPM
•Reduced energy costs / wastage
•Lower Carbon usage
•Improved Security, linking with BMS
•Notification of key issues in real time
•Billing of power usage to internal or external clients
•Communication to your PDU’s via IP over your structured cabling
87
SimpleTM Intelligent Power Management Solutions
Intelligent Power Management
New Build Data Center Schematic
Alongside the delivery of reliable power to the network environment, issues of power management are also a key concern to the
network manager: unauthorized use of power outlets, locked-up equipment, in-rush current, overloaded circuits, and the need of
remote access to power outlets within a rack.
LS addresses these concerns with a range of intelligent power strips that coupled with LS’s Power monitoring products can provide remote power
control and remote power monitoring over IP, providing the benefits of
•SNMP management (gets / sets / traps)
•Inbuilt web server
•Telnet communications.
Additionally, the power strips have terminal emulation, which is accessible via a KVM switch. Uses of the intelligent power strip solutions include:
Power balancing
IT infrastructure managers can ensure that the individual phases available within the data center are correctly balanced.
This helps prevent infrastructure failure and makes more efficient used of power delivery components such as UPS, generator, harmonic filters etc.
This also enables the infrastructure to be matched to actual enterprise needs.
Power Availability check
Power is provided to the load point using normal power delivery equipment. This usually has a finite limit before a circuit breaker cuts in to prevent
overloading and dropping the load (maybe your application servers!). This can be avoided by monitoring power closely.
Billing Stream
Monitoring KWhr enables certain organizations to bill their customers (Web hotels, hosting companies etc.) for consumed power thereby adding to
their income revenues.
Remote Reboot & Power Control
Locked up or unresponsive equipment can be rebooted remotely, saving on site visits. In addition, the power strips can be used for sequenced start
up of devices.
88
Intelligent Power Management
SimpleTM Intelligent
Intelligent
Power Management
Power Management Solutions
Power Strip Features
Monitoring Unit Features
•Individual fuses for each outlet-so one faulty load device
•Individual outlet control (with individual password protection).
•Monitor RMS Volts / RMS Amps and KW/hr.
won’t take out an entire strip.
•Threshold alarms for Amps, Volts and KW / hr (LCL, LWL, UWL, UCL).
•Power is measured 4000 times per second-true RMS readings
allow accurate KWhr readings.
•CE approved by an independent body.
•Each unit is PAT tested.
•Each unit is soak tested for a minimum 3 hours at load.
•6mm sq cables which are better suited to the IT environment.
Operating and Physical Data for Power Strip Controllers
Communication
SNMP monitoring / management Telnet management
JAVA monitoring / management applet ( Viewer )
WEB monitoringTerminal configuration
RS232 Port
RS232 for local configuration
Security
Telnet and WEB access password protection
Upgradeability
Firmware upgradeable using serial download
or TFTP download
Standards and Certifications
CE
Kit Contents
Unit, config cable, CD, mains adaptor PSU, carton
Monitoring Unit
Monitoring Unit 2
Enclosure
Steel case with epoxy powder coating 75mm wide x 149mm
Aluminium case with epoxy powder coating 90mm wide x
deep and 28mm high 0.32 kg weight
190mm deep and 32mm high 0.46 kg weight
LED Indicators
Status Network traffic
DC Power ON Status DC Network traffic RS232
PDU Port
2 x D9 male port
2 x RJ 6/4
Temperature Port
N/A
2 x RJ 4/4
Power
Input 1 x jack plug +12v DC
LAN port
RJ45 way socket 10 BaseT
Normal Power Usage
300mA
Maximum Power
400mA
Operating Range
0 ~ 40℃
Operating Humidity
5 ~ 90%
Storage Temperature
-10 ~ 70℃
Storage Humidity
5 ~ 100%
89
Monitoring Unit
Intelligent Power Management
Description & Application
Web and html based environmental monitoring and control unit.
The new generation Monitoring Unit answers the remote monitoring demands of data center
managers with a focus on security, ease of use and increased monitoring support.
Access for configuration, monitoring and control is made both easy and secure with a new
web based (https) interface. Along with an increase in basic functionality and overall
flexibility, secure ease of use has been a main focus behind the Monitoring Unit. The intuitive
web interface eliminates the need for complex serial set up processes completely.
Additionally, the Monitoring Unit delivers a unified, enterprise-wide view and access, via a
single IP address, to all the attached devices, providing significant cost saving over other IP
based monitoring offerings.
The Monitoring Unit combines with intelligent, switchable power strips to provide a complete
and powerful remote power management and monitoring system over IP.
Features
•12 x ports for sensors (combination of temperaturehumidity / Open, Close contacts).
•Auto detection on supported sensors.
•Support for 6 intelligent power strips.
•4 x digital outputs.
•2 x key pad input and door control.
•Secure Web Management and Control Interface (HTTPS).
•Optical Remote LCD display unit (for front of cabinet).
Operating Data
Features
Power Supply
Connectivity and Networking
Input Power
100 ~ 240 VAC
Network Type
Fast Ethernet (802.3u)
Input Connector
IEC Inlet C14
Network Connection
RJ45
Power Consumption
(Max) 45W
Link Speeds
10/100 Mbps with auto negotiation
Additional Information
Isolated supply and chassis ground
Network Indications
Network Link LED (Green),
Power Supply Options
48V VDC power input
Dual Power Supply
Sensors
Number of Inputs
12
Input Connector
RJ11-6/4
Parameters Monitored
Temperature, humidity,
extended range)
Temperature Monitoring Range
0℃ to 60℃
-10°∆C to 70°∆C -40°∆C to 70°∆C (Optional
Temperature Monitoring Accuracy
±5%RH @ 25℃
extended range)
Temperature Hysteresis
Programmable 0.1℃ to 9.9℃ in 0.1
Operating Environment
Operating Temperature
Storage Temperature
10/100 Mbps LED( Yellow)
0°∆C to 45°∆C -15°∆C to 50°∆C (Optional
Open/Close contacts
Operating Humidity
15% to 85% RH
Storage Humidity
5% to 90% RH
Humidity Monitoring Range
30% to 90% Relative humidity
MTBF
> 100,000 Hrs
Humidity Monitoring Accuracy
±5% RH @ 25℃
increments
Humidity Hysteresis
Programmable 0.1%RH to 9.9%RH in
0.1 increments
Analog Resolution
Additional Information
12 bit A/D
inputs are not isolated. Auto detection of
supported LS sensors
90
Intelligent Power
Monitoring
Unit Management
Number of Inputs
6
LCD Status Monitor
PDU Input Connector
Rj11 - 6/6
The optional backlit LCD
Summary page displaying configured
Parameters Monitored
Voltage, Current, kilo-watt hours(kWh),
status monitor can display
PDUs and Inputs 1 and 2.
kilo volt-ampere (kVA)
the following:
Voltage Monitoring Range
0 V to 500 V
All 12 Digital Inputs.
All 6 PDUs.
Voltage Monitoring Accuracy
± 2%
The following system
Firmware Version
Current Monitoring Range
0 A to 65 A
information is also available
IP Address
Current Monitoring Accuracy
± 2%
Subnet Mask
Kilo-watt hours Monitoring Range
0 kWh to 429496729 kWh
Gateway
Kilo-watt hours Monitoring Accuracy
Dependent on PDU
Kilo volt-ampere Monitoring Range
0 kWh to 429496729 kVA
Kilo volt-ampere Monitoring Accuracy:
N/A
Intelligent Power Management
PDU Monitoring and Control
MAC Address
Additional information
Backlit
Powered from unit (no additional
Output Relays
power source required)
Number of outputs
4
Status indicators
Output Connectors
Screw lock WeidMuller (Outputs 1 and 2),
Units front panel provides
Power (Green)
Screw lock Phoenix Contact
the following LED
Status (Green)
(Output 3 and 4)
indications
Network Link (Green)
Output modes
Normally Open, normally Closed
Network Speed (Yellow)
Maximum switching
48 V at 1 A (Resistive load)
Digital Output (Yellow)
Additional information
Outputs 1 and 2 offer a 12+ V DC
Analogue Input (Red)
supply fused at 1amp
Digital Input (Red)
Monitoring and Configuration
The following monitoring
Web management interface via HTTP
and configuration methods
or HTTPS (Secure)
are provided
SNMP
91
Intelligent Power Management
Intelligent Power Distribution Unit (i-PDU)
Description
The i- PDU’s provides a modular and flexible solution for the Remote Monitoring, Control and Management of today’s power needs to mission critical
and remote equipment, where zero down time and maximisation of operations is a pre-requisite. The i-PDU’s are available in 10, 13, 16 and 32 Amp
load ratings. Used with the Link Box Distribution Units, a total Power Monitoring and Control solution, is provided, meeting all Data Center, and
Computer Room applications. The i-PDU’s offer a wide range of options, including, a range of socket outlet types, 13A UK, International and C13,
C19, [individually fused with Power on indicators], Vertical and 19” Horizontal mount, Ideal for large Servers, Disk Storage Arrays, Blade server
enclosures and Network switches. As an Integral part of the LS Integrated solution, the i-PDU’s can sequentially Power up socket outlets to protect
against Current inrush, Remotely Power on/off individual socket outlets, accurately Measures critical Power information via secure polling and real
time SNMP. The Intelligent Management Software, can be used to Monitor, Control, Generate out of norm and critical Alarms, Management Reports
and Trend Analysis, to provide truly Integrated and tailored solutions, meeting customer specific requirements.
Standard Features include
Specification
•Integrated, Scalable, Modular solution
Connectivity
EIA RS232 or RS485 Modbus
•Economical, cost effective
Rated Voltage
230V, AC Nominal
•Range of Socket outlet types
Rated Current
Up to 32A, AC
•Up to 24 socket outlets
Rated Frequency
48 Hz to 62 Hz.
•Sequential Power up
Operating Temperature
-10 to +85 degrees Celsius
•Remote Power on/off of individual sockets
Measuring Accuracy
+/-2%, kWhr to EN61036, IEC1036, EN1010-1
•10, 16 and 32Amp load rating options
Local Display
LCD of current, Voltage and kWhr
•Single or multi site applications
Display Resolution
1 Volt, 0.01 Amp, 0.1 kWhr
•Fully featured Management Platform
Max socket rated Current
16A
•Set alarm thresholds provide Management,
Breaking Voltage
230v AC/440V AC
Max Breaking Capacity
4000VA
•Local LCD display of Voltage, Current and kWhr
Max socket Current
30A, at 4 sec at duty cycle 10%
•CE Approved
Peak inrush Current
80A [20 ms]
•Remote Current, Voltage and kWhr monitoring
Input Cable length
3 Metres
•Vertical and 19”, Horizontal rack mounting
Mechanical Dimensions:
Please refer to Data Sheet Drawings
Material
Metal, Colour Black
Trend analysis Reporting
options
•Easy to use
•Secure real time SNMP and Polling
Please note
Other options are available on request. Please contact LS’s Sales office
92
Intelligent Power Distribution
Management
Unit (i-PDU)
Item
i-PDU’s
10A IEC [C13’s]
Part Description Code
PDU-H-16-RMC-COM16-N3-8C13-IF-P
Part No
Description
LS-IPDU-2215
Mon + Cont, 16A, 8 10A IEC's Horizontal ind fuse/neon, Com plug
PDU-H-32-RMC-COM32-N3-8C13-IF-P
LS-IPDU-2225
Mon + Cont, 32A, 8 10A IEC's Horizontal ind fuse/neon, Com plug
PDU-H-16-RMC-COM16-N3-12C13-IF-P
LS-IPDU-2235
Mon + Cont, 16A, 12 10A IEC's Horizontal ind fuse/neon, Com plug
PDU-H-32-RMC-COM32-N3-12C13-IF-P
LS-IPDU-2245
Mon + Cont, 32A, 12 10A IEC's Horizontal ind fuse/neon, Com plug
PDU-V-16-RMC-COM16-T3-12C13-IF-P
LS-IPDU-2315
Mon + Cont, 16A, 12 10A IEC's Vertical ind fuse/neon Com plug
PDU-V-16-RMC-COM16-T3-16C13-IF-P
LS-IPDU-2325
Mon + Cont, 16A, 16 10A IEC's Vertical ind fuse/neon Com plug
PDU-V-16-RMC-COM16-T3-24C13-IF-P
LS-IPDU-2335
Mon + Cont, 16A, 24 10A IEC's Vertical ind fuse/neon Com plug
PDU-V-32-RMC-COM32-T3-12C13-IF-P
LS-IPDU-2345
Mon + Cont, 32A, 12 10A IEC's Vertical ind fuse/neon Com plug
PDU-V-32-RMC-COM32-T3-16C13-IF-P
LS-IPDU-2355
Mon + Cont, 32A, 16 10A IEC's Vertical ind fuse/neon Com plug
PDU-V-32-RMC-COM32-T3-24C13-IF-P
LS-IPDU-2365
Mon + Cont, 32A, 24 10A IEC's Vertical ind fuse/neon Com plug
i-PDU’s
PDU-V-16-RMC-COM16-T3-8UK-NF-P
LS-IPDU-3115
Mon + Cont,16A,8UK,Vertical, Com plug
PDU's 13A UK
PDU-V-16-RMC-COM16-T3-12UK-NF-P
LS-IPDU-3125
Mon + Cont,16A,12UK,Vertical, Com plug
PDU-V-16-RMC-COM16-T3-16UK-NF-P
LS-IPDU-3135
Mon + Cont,16A,16UK,Vertical, Com plug
PDU-V-32-RMC-COM32-T3-8UK-NF-P
LS-IPDU-3145
Mon + Cont,32A,8UK,Vertical, Com plug
i-PDU's
PDU-V-16-RMC-COM16-T3-4C19 20C13-IF-P
LS-IPDU-4115
Mon + Cont,16A, 4 16A 20 10AIEC'sVertical indfuse/neon Com plug
MIXED SOCKETS
PDU-V-32-RMC-COM32-T3-4C19 20C13-IF-P
LS-IPDU-4125
Mon + Cont,32A,4 1 6A,20 10AIEC'sVertical indfuse/neon Com plug
PDU-V-16-RMC-COM16-T3-4UK 20C13-IF-P
LS-IPDU-4115
Mon + Cont,16A, 4UK, 20 10AIEC's Vertical indfuse/neon Com plug
PDU-V-32-RMC-COM32-T3-4UK 20C13-IF-P
LS-IPDU-4125
Mon + Cont,32A, 4UK, 20 10AIEC's Vertical indfuse/neon Com plug
Intelligent Power Management
Part Numbers
Customer Specific i-PDU’s are available on request, as defined by the product Coding Matrix and allocated a PDU 7000 series Part No
Please note
Other options are available on request. Please contact LS’s Sales office
93
Remote Monitoring Link Box
Intelligent Power Management
Description
The LS Link Box provides a modular and flexible solution for the Remote Monitoring and
Management of today’s power needs to mission critical and remote equipment, where zero
down time and maximisation of operations is a pre-requisite.
The LS Link Box is available in 16 Amp, 32 Amp Single phase and 32 Amp, 63 Amp Three
phase options. Used with The LS Power Distribution Units, a total Power Monitoring and
Control solution, is provided, meeting all Data Center, and Computer Room applications.
The LS Link Box is specifically designed for devices requiring one or more direct power feeds.
Ideal for large Servers, Disk Storage Arrays, Blade server enclosures and Network switches. The devices can be free standing or installed in Server
cabinets for New Build and Retrofit fit applications.
As an Integral part of the LS Integrated solution, The LS Link Box accurately Measures critical Power information via secure polling and real time
SNMP.
The LS Intelligent Management Software, can be used to Monitor, Control, Generate out of norm and critical Alarms, Management Reports and Trend
Analysis, providing truly Integrated and tailored solutions, to meet customer specific requirements.
Standard Features include
Specification
•Integrated, Scalable, Modular solution
Connectivity
EIA RS232 or RS485 Modbus
•Economical, Cost effective
Rated Voltage
230V, AC Nominal Single Phase,
•New build and Retro fit applications
415V, AC Nominal Three Phase
•Single or multi site applications
Rated Current
•Range of load rating options
Up to 32A, Single Phase,
Up to 63A, Three Phase
•Fully featured Management Platform
Rated Frequency
48 Hz to 62 Hz.
•Set alarm thresholds provide Management, Trend
Operating Temperature
-10 to +85 degrees Celsius
Measuring Accuracy
analysis Reporting
+/-2%,
kWhr to EN61036.IEC1036
•Single and Three phase solutions
•CE Approved
Local Display
LCD of current, Voltage and kWhr
•Remote Current, Voltage and kWh monitoring
Display Resolution
1 Volt, 0.01 Amp, 0.1 kWhr
•19”, ETSI Horizontal rack mounting
Input Plug/Cable length
IEC 309, 2 Metres
•Easy to use
Output Plug/Cable length
IEC 309, 2 Metres
•Simple to install
Mechanical Dimensions:
1U, 19” [Single Phase]
Lxxx mm, W xxx, H xx mm
•Secure real time SNMP and Polling
Material
Metal, Colour Black [Single Phase]
Rugged Plastic [Three Phase]
Safety Standards
EN 60950-2000, EN 61010-1
Part Numbers
AA
Description
Part No
Description
Link Box
PDU-SLB-16
LS-IPDU-1110
Single supply Link Box 16A IEC 309 Plugs and Sockets
Single Phase
PDU-SLB-32
LS-IPDU-1120
Single supply Link Box 32A IEC 309 Plugs and Sockets
PDU-DLP-16
LS-IPDU-1210
Dual supply Link Box 16A IEC 309 Plugs and Sockets
PDU-DLP-32
LS-IPDU-1220
Dual supply Link Box 32A IEC 309 Plugs and Sockets
Link Box
PDU-SLB-32T
LS-IPDU-1110T
Single supply Link Box 32A IEC 309 Plugs and Sockets
Three Phase
PDU-SLB-63T
LS-IPDU-1120T
Single supply Link Box 63A IEC 309 Plugs and Sockets
Please note
Other options are available on request. Please contact LS’s Sales office
94
Temperature Sensor
Intelligent Power Management
Intelligent Power Management
Sensors
Part No : LS-IPM-H2-S-T
Technical Details
Temperature Monitoring Range: 0℃ to 60℃
Temperature Monitoring Accuracy: ± 5% Standard Transducer @ 20℃
Temperature Hysteresis: Programmable 0.1oC to 9.9℃ in 0.1℃ increments
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the Monitoring Unit sensor ports
Humidity Sensor
Part No : LS-IPM-H2-S-H
Technical Details
Humidity Monitoring Range: 30% to 90% Humidity
Humidity Monitoring Accuracy: ± 5% RH @ 25℃
Humidity Hysteresis: Programmable 0.1%RH to 9.9%RH in 0.1 increments
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the Monitoring Unit sensor ports.
The Sensor is housed in a plastic enclosure for protection.
Keypad
Part No : LS-IPM-H2-S-KM
Technical Details
5x2 Matrix Type
No Additional Power Source Required – Directly Powered from Keypad Port on Monitoring Unit unit
Supplied with 2m of Ribbon Cable with 450mm of Plastic Flexible conduit for Protection within the cabinet
Water Sensor – Rope Type
Part No : LS-IPM-H2-S-WR
Technical Details
Control Housing is made from tough ABS plastic
Control Housing Dimensions: 74mm Wide x 50mm High x 27mm Deep
Standard Rope Length: 5m
Standard Control Cable Length: 2m (Terminated by RJ10 Connector)
Power Supply (5v – Powered by Monitoring Unit)
Supply Current: 20mA
Door Contact (MicroSwitch)
Part No : LS-IPM-H2-S-D
Technical Details
MicroSwitch Type Contact
Simple Installation (No Fixings Supplied)
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the
Monitoring Unit sensor ports.
Door Contact (Magnetic)
Part No : LS-IPM-H2-S-DM
Technical Details
Magnetic Type Contact
Simple Installation (No Fixings Supplied)
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the
Monitoring Unit sensor ports.
95
Intelligent Power Management
Sensors
Water Sensor (Contact Type)
Part No : LS-IPM-H2-S-WC
Technical Details
Compact Unit suitable for multiple installation locations
Contact Type
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the
monitoring unit sensor ports.
Smoke Detector
Part No : LS-IPM-H2-S-S
Technical Details
Contact Type
Test Button
Easy Installation – Standard Fixings Supplied
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the
monitoring unit sensor ports.
PIR Sensor
Part No : LS-IPM-H2-S-P
Technical Details
Contact Type
Can be powered directly from monitoring unit or external power supply
Simple Installation (Fixings Supplied)
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the
Monitoring sensor ports.
Beacon (No Sounder)
Part No : LS-IPM-H2-S-B1
Technical Details
Flashing Strobe Light (Standard Colour: Red)
Simple Installation (Fixings Supplied)
Powered directly from the Monitoring unit
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the
Monitoring Unit sensor ports.
Beacon (With Sounder)
Part No : LS-IPM-H2-S-B2
Technical Details
Flashing Strobe Light (Standard Colour: Red)
Configurable Alert Sounds (Switch Settings)
Volume Control
Simple Installation (Fixings Supplied)
Powered directly from the Monitoring unit
The Sensor is supplied with 2m of cable terminated with an RJ10 for direct connection to one of the Monitoring Unit sensor ports.
Please note
Other options are available on request. Please contact LS’s Sales office
96
Intelligent Power Management Software
Intelligent Power Management
Description
As a web-based application allows users to monitor and control hundreds or even thousands of devices from a single console. Through our secure
web interface, you can view the infrastructure from any browser within the company intranet.
Attractive, Intuitive Layout
•Real-world representation of your infrastructure
•Import your own data center layout
• Drill down to the rack level
Easy to use
•Clear, easy to read intuitive screens using
Macromedia Flash with real-time updating
•Automatically discovers supported devices
•Minimal SNMP knowledge required (no MIB
compilation)
•Configurable hierarchy allows you to easily
group devices by location, type or function
Logging
•Provides individual device log files for
trending and event logging purposes
•Users can easily manage inventory and
create and save custom reports
Intelligent Alarm Processing
•Only active alarms are displayed in the alarm
viewer (all alarms are saved to log file)
•Recognizes when an alarm condition has
cleared and automatically updates the alarm
display and event log
Global sets
•Configure multiple devices with a single click
Multi-protocol Support
•SNMP
•Telnet
•Web (secure and non-secure)
•XML
•Modbus
97
Intelligent Power Management Software
Intelligent Power Management
Technical Details
Device Discovery
Automatically discovers SNMP devices, Business Edition UPS software, secure and non-secure Web servers, Telnet devices
Topology Layout
Configurable hierarchy structure allows you to easily group devices by location, type or function. Support for nested groups allows
Advanced Layout View
Create customized layouts by choosing the size and position of device icons. Import your own background images to fully
and more. Support is also included for manually adding non-discoverable devices
you to design a topology that fits your needs
customize your layout
Detailed Rack View
Drill down to the rack level to view rack contents and status of all rack devices
Real-Time Alarm Monitoring
Macromedia Flash interface provides real-time updating without screen refresh
Accessible from any Browser
View the status of your infrastructure from any browser on your company intranet
Security
Secure Socket Layer (SSL) support for web security
Extensive Reporting
View summary and detailed event logs, inventory reports, and device parameters. Create and save custom reports. Configure
Intelligent Alarm Processing
When an alarm condition clears, the active alarm will be automatically removed from the alarm viewer. There is no need to
recurring reports to be sent automatically via email
manually clear every alarm as is required for many network management systems
SNMP
Notification Send SNMP traps to multiple trap receivers when events occur
Broadcast Notification
Send broadcast messages to multiple recipients when events occur
Email/Pager Notification
Send email or alphanumeric pages to multiple recipients when events occur. Select working days and hours for email/pager
recipients so they will only receive notification when it is appropriate
Alarm Escalation
Escalate alarms if not resolved after a selected period of time
Centralized Configuration
Configure hundreds of devices at the same time using Enterprise
System Requirements
Operating Systems
Supported Windows 2000 (service pack 4 or higher), Windows XP Professional (service Pack 1 or higher),
Windows 2003 Server Enterprise Edition
98
Web Browsers Supported
Internet Explorer 6.0 (Service Pack 1), Macromedia Flash 7.0
Database
MSDE 2000 (Service Pack 3) - included with the software
IntelligentKit
Power
Management
CL-Amp
Solution
Intelligent Power Management
Non-Invasive retrofit Data Center Schematic
'Out of the Box' CL-Amp Kit Overview
With legacy data centres known to be operating at the extremes of their design capability and beyond, there is an urgent need to
provide a 'non-invasive' current monitoring solution to retrofit, legacy and new build data centres, in order to monitor and increase
visibility of power usage, help regain power and cooling capacity and ultimately enable clients to benefit from attendant cost savings,
without the scheduled power downtime associated with traditional monitoring technologies.
To facilitate deployments, LS has configured a simple, cost effective, 'out of the box' kit solution, specifically designed for a single
cabinet installation, removing the need to setup complex SNMP based network management systems. The kit comprises of all the
necessary constituent component parts required for your 'non-invasive' current monitoring solution and consists of the following:
•2 x CL-Amp devices.
•2 x sets of cable collars supplied to support: 8mm to 18mm diameter cables.
•1 x PowerHawk2.
•1 x Temperature sensor.
•1 x spare sensor port.
•1 x CD copy of Env-U, a client based application.
•1 x set of 2m interconnecting patch cables from the CL-Amp to the PowerHawk2.
•1 x instruction manual.
99
Intelligent Power Management
CL-Amp Kit Solution
What the ‘Out of Box’ Kit Provides
The CL-Amp kit is intended to supply an all in, one easy to install, solution providing 'non-invasive', real-time current monitoring
functionality to non-intelligent power strips and measurement of A.C. currents on typical data centre power supply feeds rated up to 32A.
The PowerHawk2, as an ideal product that supports single cabinet power and environmental monitoring solutions using a single IP
address, is the monitoring device of choice within the kit to provide the CL-Amp with power and a communication link. The 'out of the
box' kit solution also provides, as standard, temperature monitoring, with the inclusion of a temperature sensor.
The second sensor port on the PowerHawk2 has been left spare for the client to decide, which additional sensor monitoring is most
suitable for their application, i.e. humidity, or an additional temperature sensor. The additional sensor can be retrofit at any time.
To further enhance the 'out of the box' kit solution, a simple client software application, has been provided, known as Env-U. This
desktop application will provide both a live and historical view of current, temperature and humidity data readings, in addition to
providing simple trending information of the parameters monitored where basic management reports can be easily created and
exported into Excel or CSV formats.
Component Parts of the Kit
CL-Amp
The CL-Amp is a unique innovative new product, designed and manufactured
by LS, to provide the urgently needed 'non-invasive' current monitoring solution
into retrofit, legacy and new build data centres.
For the purpose of the 'out of the box' CL-Amp kit solution, the CL-Amp is powered
by the PowerHawk2, which also provides the necessary communication link to
the CL-Amp, allowing the measured electrical current to be read.
The CL-Amp enables the 'non-invasive' real-time monitoring of current for any
device or power strip, rated up to 32A. Devised with an open fork in the high quality
and robust plastic, it is placed directly over a power cable with a choice of lockingring collars to suit most international 13A, 16A and 32A cable sizes provided.
Each locking ring separates into two halves and is placed around the power
cable and pushed into the CL-Amp clamping bore, retaining the cable with a
neat twist and lock action. A very lightweight device, it is designed to be
installed at any convenient location on the cable.
Local and remote monitoring is achieved by connecting the CL-Amp to the PowerHawk2 monitoring device, with local monitoring via
an integral LED display on the CL-Amp.
Product Features
•'Non-invasively' monitors standard 3 core single phase AC power cables [L, N & E], without the need to specifically identify and
measure the live conductor only.
•Current measuring range 1.0 Ampere to 60 Amperes.
•Measured supply range: 90VAC ~ 250VAC. Frequency : 50Hz ~ 60Hz A.C.
•Size : 134mm x 88.5mm x 41mm, Weight : 135gm
•RS232 / RS485 communication link to the PowerHawk2 monitoring device, to provide SNMP data collection, monitoring, and
configuration of the CL-Amp.
•RJ45 connector for direct connection to the PowerHawk2.
•12V DC power supply @60mA (typically supplied direct from the PowerHawk2).
•Cable collars supplied to support : 8mm to 18mm diameter cables.
•Local LED display provides two digit readout.
•Can be calibrated to cable types to provide typically ±3% accuracy Ampere current readings.
100
PowerHawk2
As part of the ‘out of the box’ kit solution, it is the PowerHawk2 that is used to power the CL-Amp and read the associated data.
The PowerHawk2 is a cost effective monitoring and control solution, which enhances LS family of other product portfolio.
The PowerHawk2 has
specifically been designed
with simplicity in mind, to
provide single rack level
power and environmental
monitoring, using a single
IP address.
Intelligent Power Management
IntelligentKit
Power
Management
CL-Amp
Solution
Ideal for single cabinet
installations, the PowerHawk2
supports up to two CL-Amps,
monitoring amps.
In addition, two environmental input sensors are supported, which can be any combination of temperature and/or humidity.
The PowerHawk2 allows up to 5 SNMP Network Management Station (NMS) addresses to access the unit. Alarm conditions will
generate trap messages, which can be directed to a maximum of 10 specified management stations. SNMP alarm trap thresholds
may be set on any of the input measured parameters, i.e. amps, temperature and humidity.
Product Features
•SNMP agent optimised for rack management.
•HTTP/HTTPS web interface for management and power strip control.
•Support for 5 Network Management Stations (NMS) to access the unit.
•Allows up to two CL-Amps, monitoring amps.
•Allows up to two auto sense analogue input channels per cabinet, which can be any combination of temperature or humidity.
•All alarm thresholds can be user defined and configured through an easy to use web interface or managed via SNMP for
configuration and monitoring.
•Optional display unit for monitoring sensor and power information outside the rack environment
•LDAP login support.
•Real Time Clock (RTC) with battery backup.
Env-U Client Application
Env-U is an 'in-house' developed client application, included as part of the 'out of the box' kit solution to provide both a live and
historical view of current, temperature and humidity data readings, coupled with simple trending information of the parameters
monitored, allowing basic management reports to be easily created and exported into Excel or CSV formats.
Product Features
•Simple client based application.
•Uses standard SNMP protocol to support the PowerHawk2 device.
•Supports up to a maximum of 25 nodes. 1 PowerHawk2 = 1 node.
•Supports three types of sensor; 2 x CL-Amps and 2 x sensors.
•Polls devices and creates and logs SNMP traps as alerts.
•Live and historical view of data.
•Simple trending information and management reports.
101
Intelligent Power Management
CL-Amp Kit Solution
Figure 1.0 Application Overview
The Env-U application is intended to collect the CL-Amp electrical current data and the temperature/humidity readings from the
PowerHawk2 device. Using standard SNMP protocol, Env-U will monitor up to a maximum of 25 networked PowerHawk2 agents.
Three types of sensor are supported, namely :
•2 x electrical current data readings from the CL-Amp.
•1 x temperature sensor.
•1 x spare sensor port for a humidity or second temperature sensor.
Figure 2.0 Env-U shows a historical view of temperature changes over a given time period.
Based on Microsoft .NET framework version 2.0, Env-U is capable of logging any SNMP alarms that are generated by the agent
devices. The agent devices will be polled at regular intervals and the read data collected and stored in the applications database at
one minute intervals, for a maximum of 186 days. In addition to the polling and capture of data, it is important for Env-U to provide
and log alarm messages as SNMP traps when user defined thresholds are exceeded.
Env-U is not a full SNMP Network Management Station. For large installations or if further feature sets are required, clients may
upgrade to our Enterprise Device Management software application.
102
SimpleViewTM
Intelligent Cabling Management Solutions
SimpleViewTM Intelligent Cabling Management Solutions
SimpleViewTM Hardware
SimpleViewTM Copper Patch Panel
SimpleViewTM Fiber Optic Patch Panel
SimpleViewTM Fiber MPO Patch Panel
SimpleViewTM Patch Cord (Copper & Fiber)
SimpleViewTM Accessories
SimpleViewTM Management Software
SimpleViewTM Site Pro
SimpleViewTM
Intelligent Cabling Management Solutions
SimpleViewTM‚ is a management tool that enables network & facilities personnel from various groups, such as Infrastructure, IT, Operations and
management to keep the business running smoothly by tracking key performance indicators (KPI's). It is a user personalized application that provides
SimpleViewTM Intelligent Solutions
up-to-date information and instant notifications based on flexible event policies.
Manage and control your network infrastructure through:
•Real-time user configurable KPI’s
•Early-warning indicators
•Real-time analysis
•Highly intelligent personalized alert policies and real-time alerts
•Graphical reports, graphs and gauges
•Guided drill-down capabilities to pinpoint the root cause of a problem
SimpleViewTM takes the guesswork and legwork out of managing the infrastructure
and physical layer of your network.
Control over infrastructure and networked devices.
SimpleViewTM‚ drastically speeds up and simplifies site planning and daily network
provisioning, maintenance and security and provides comprehensive visibility into
datacenter and work space facilities, keeping an accurate inventory of all assets whether located across a campus or an ocean.
104
SimpleViewTM
SimpleViewTM Intelligent Solutions
Intelligent Cabling Management Solutions
Description
SimpleViewTM is an intelligent cabling system that uses SNMP to monitor the network cabling connectivity in real time. Combined with Layer 2 & 3
Features
•Real-time management using SimpleViewTM technology
•Web-based application allows unlimited concurrent users logins via MS browser from anywhere on the network
•Unlimited number of managed sites in one central database
•Complete cabling system solution
•All components are qualified to latest industry standards by independent testing laboratories
•25-year warranty on installations
SimpleViewTM Intelligent Solutions
information it provides accurate, real-time, end-to-end connectivity information for every network device
Benefits
•SimpleViewTM delivers automated analytics across the network physical infrastructure:
•Capture and discover real-life information from all connections, network devices & elements
•Analyze connection status across locations & users
•Respond to multiple events & operational criteria for full visibility & centralized connection-based management
Structure
105
SimpleViewTM Hardware
Description
SimpleViewTM hadrware is configured in a hierchical layout and is the interface between the SimpleViewTM Patch Panels, providing the management
SimpleViewTM Intelligent Solutions
software with all relevant data to scan connectivity changes within the physical layer.
Products
Master
•Collects the connectivity data from the system
•Capable of monitoring up to 8 Communicaton rooms
Expander
•Connects to one port on the Master via the uplink port
•Can connect to 8 scanners or 8 Expanders or any combination of scanners/expanders
•Multiple levels of Expanders can be cascaded
Master Expander
•Master and Expander packaged together
•Supports 1 Communication room
Scanner
•Can monitor up to 24 panels
•The SimpleViewTM patch panels are connected to the Scanner at the back with flat cables
(attachment cords)
Mini Scanner
•Can monitor up to 12 panels
•Suitable for small Comm. rooms
•The SimpleViewTM patch panels are connected to the Mini-Scanner with flat cables
(attachment cords)
Indicator Controller
•Controls and activates the Rack Indicators (Chakalaka) in conjunction with any LED on the
SimpleViewTM Patch Panels in the rack/s
•Connects to any port on a Master
•Can be connected to 8 racks
106
SimpleViewTM Hardware
Intelligent Solutions
Products
Security Controller
•The SimpleViewTM patch panels are connected to the Scanner at the back with flat cables
(attachment cords)
Local Master
•An excellent cost - effective solution for small and medium IT organizations
•Able to monitor up to 24 panel (576ports)
•Collects, saves, and transmits connectivity data from the SimpleViewTM Patch Panels
•Built-in control button capabilities
SimpleViewTM Intelligent Solutions
•Can monitor up to 24 panels
Local Scanner
•An excellent cost - effective solution for organizations with remote branches
•Able to monitor up to 6 panels (144ports)
•Collects, saves, and transmits connectivity data from the SimpleViewTM Patch Panels
Inter-Connection
•A robust solution to the interconnect environment for both existing and new installations
•Simple and fast installation with minimum interference to the network operation
•LED guidance for management
•Modular - special design enables rapid customization for any switch
Part Numbers & Physical Chracteristic
Description
Dimensions (mm)
Part Number
SimpleViewTM Master (4 port)
44.4(H) x 482.6(W) x 159.3(D)
LS-Master-4Port
SimpleViewTM Expander
44.4(H) x 482.6(W) x 159.3(D)
LS-Expander
SimpleViewTM Master Expander
44.4(H) x 482.6(W) x 159.3(D)
LS-Master Expander
SimpleViewTM Scanner
44.4(H) x 482.6(W) x 191.7(D)
LS-Scanner
SimpleViewTM Mini Scanner
44.4(H) x 482.6(W) x 191.7(D)
LS-Mini Scanner
SimpleViewTM Indicator Controller
44.4(H) x 482.6(W) x 159.3(D)
LS-Indicator Controller
SimpleViewTM Security Controller
SimpleViewTM Local Master
44.4(H) x 482.6(W) x 159.3(D)
44.4(H) x 482.6(W) x 159.3(D)
LS-Security Controller
LS-Local Master
SimpleViewTM Local Scanner
44.4(H) x 482.6(W) x 191.7(D)
LS-Local Scanner
SimpleViewTM Inter-Connection Solution
88.0(H) x 482.6(W) x 159.3(D)
LS-Inter-Connection
107
SimpleViewTM Hardware
SimpleViewTM Intelligent Solutions
Specifications(Excludes 6527 1736-00)
Panel rack mounting
1U 19 (IEC 60297)
Product weight
2.0 Kg / 4.4 lb
Interfaces
Up/down links
Standard RS-485, Full-duplex connector shielded RJ-45 socket
Serial
Data rate up to 115.2 Kbps
RS-232
Connector 9-pin D-type male
Data rate up to 115.2 Kbps
Protocol UART, start bit 1,
Stop bit 1, non-parity
100BASE-Tx
RJ-45 socket, Ethernet IEEE 802.3, 100BASE-Tx / 10BASE-T,
100/10 Mbps industry standard for connection to
local area network
Control pad
Connector RJ-45 socket, 8 pins
LED Indicators (Where used)
Patch panel connections
Connectors 6 or 12 headers, 26-pin
PWR
On when scanner is powered
CPU
Blinking to indicate master heartbeat
DOWN LINKYELLOW
On during transmission of each of the DOWN LINK ports
DOWN LINKGREEN
On during reception of each of the DOWN LINK ports
100BASE-Tx - Rx
On during reception from local area network
100BASE-Tx - Tx
On during transmission to local area network
Environmental and Safety
100BASE-Tx LINK
On when link is active
Operating temperature range
0
Operating humidity range
108
- +50
90% relative humidity non-condensing
Safety
UL 60950, EN 60950
EMC
EN 55022, FCC part 15 Class A, EN 55024
Power
100 ~ 240 VAC, 47 ~ 63 Hz, 30W maximum
SimpleViewTM Copper
Intelligent
Patch
Solutions
Panel
Description
SimpleViewTM's large selection of Category 6A, Category 6, enhanced Category 5 and Category 5 patch panels cover all LAN cabling requirements.
SimpleViewTM Patch Panels incoporate pair-balancing technology for optimum performance and LED indicators on the panels identify any two ports
patched together and enable 100% accurate Moves, Adds an Changes. Patch panels with “Patching Switches” offer a robust system that significantly
SimpleViewTM Intelligent Solutions
reduces the need for patch cords.
Products
Category 6A Patch Panel
•24 port 1U high
•Fully tested to 500 MHz
•Exceeds requirements of latest draft for CAT6a °© EIA/TIA 568-B.2-10
•Unique printed circuit design and pair-balancing technology for optimum performance
•Backward compatibility with CAT6 components
•STP models feature sealed casing for superior EMI/RFI protection
Category 6(High-Density)
•Superior CAT 6 performance up to 250 MHz
•Full SimpleView support
•UTP models feature CAT 6 performance up to 250 MHz
•STP models feature sealed casing for superior EMI/RFI
protection
109
SimpleViewTM Copper Patch Panel
SimpleViewTM Intelligent Solutions
Products
Category 6 Patch Panel
•This 24 Patch Panels models, when used in conjunction with SimpleViewTM System,
are able to scan the wiring center configuration and subsequently report the connectivity status
•Patching information is displayed on the management station for cabling management
applications
•LED indicators on panels identify any two ports patched together
•Computerized LED displays guide the technician when performing Moves, Adds and Changes
(MACs)
Category 6 Modular Jack Panel
•1U 24ports Modular Patch Panel
•LED indicators on panels identify any two ports patched together
•Computerized LED displays guide the technician when performing Moves, Adds and Changes
(MACs)
UTP & STP RJ to RJ Patch Panel
•A rear RJ-45 modular jack for simple connection makes the panel a labor-saving device
that does not require a termination tool
•Available in UTP and STP options
•Available in Cat5e and Cat6 options
110
SimpleViewTM Copper
Intelligent
Patch
Solutions
Panel
Description
SimpleViewTM 10G Category 6A Unshielded Patch Panel
Dimensions (mm)
Part Number
44.0(H) x 482.6(W) x 35.0(D)
LS-IPP-UC6A-XX
SimpleViewTM 10G Category 6A Shielded Patch Panel
44.0(H) x 482.6(W) x 35.0(D)
LS-IPP-SC6A-XX
SimpleViewTM Category 6 Unshielded Patch Panel(With Switch Ports)
88.0(H) x 482.6(W) x 35.0(D)
LS-IPP-UC6-48P-W/S
SimpleViewTM Category 6 Unshielded Patch Panel
44.0(H) x 482.6(W) x 35.0(D)
LS-IPP-UC6-XX
SimpleViewTM Category 6 Shielded Patch Panel
44.0(H) x 482.6(W) x 35.0(D)
LS-IPP-SC6-XX
SmpleViewTM UTP & STP RJ to RJ Patch Panel
44.0(H) x 482.6(W) x 35.0(D)
LS-IPP-RJ-XX
XX Denotes Ports : 24=24Ports, 48=48Ports
Specifications
Panel rack mounting
Plug / jack mating cycles
Plug / jack insertion / withdrawal force
Product weight
1U 19 (IEC 60297)
750 (IEC / EN 60603-7 Series)
20N(UTP), 30N(STP) (IEC / EN 60603-7 Series)
SimpleViewTM Intelligent Solutions
Part Numbers & Physical Chracteristic
0.9 Kg / 1.9 lb including jacks (UTP), 2.2 Kg / 4.8 lb (S/FTP)
Electrical
Insulation resistance
Dielectric strength
500M
Contact / contact 1.0 kV
Current carrying capacity
1A / contact
Typical plug / jack resistance
20m
Conductor terminations of LSA-PLUS£ó contacts
Conductor diameter
30
0.5 - 0.65 mm (AWG 22-24)
Panel
Signal voltage
5V dc
Signal current
2 mA max (EN60950:2000)
Testing requirements of connection technology
according to ISO / IEC 11801 2nd edition
ANSI/TIA-568-B.2.1 and EN50173-1:2002
Environmental and Safety
Operating temperature range
-10
Operating humidity range
≤ 95% relative humidity non-condensing
- +60
111
SimpleViewTM Fiber Optic Patch Panel
Description
Fiber optic patch panels, supporting both multi mode and single mode applications, offers 96, 48 and 12 fiber models. In addition, a complete line of
accessories for securing, organizing and protecting fusion spliced fibers is available. LED indicators on the panels identify any two ports patched
SimpleViewTM Intelligent Solutions
together and enable 100% accurate Moves, Adds an Changes.
Products
Fiber Patch Panel(LC)
•F/O Modular Patch Panel
•Very high density, 1U
•Up to 24 duplex LC adapters
•Single Mode and Multi mode
•Pullout drawer for easy access
•Rear and side cable entries
•Up to 24 MT-RJ adapters
•Up to 24 simplex SC adapters
•Blank covers for unused ports
•High-end performance and reliability
Fiber Patch Panel(SC)
•High density, 24 duplex adapters (48 fibers) in a 2U rack space
•Preassembled SC to SC or SC to ST adapter options
•Pull out drawer for easy access
•Large work area for comfortable installation
•Rear and side cable entries
•Innovative SNMP real-time management of patch cord connections
Fiber Patch Panel-LC 8 x 8
•LC 16 Patch Panel
•Up to 16 duplex LC adapters
•Single Mode and Multi mode
•Pullout drawer for easy access
112
SimpleViewTM Fiber
Intelligent
MPOSolutions
Patch Panel
The SimpleViewTM LC-MPO 48 Patch Panel is an intelligent, high-density fiber optic patch panel offering the option of real-time physical network
management with LS SimpleViewTM system. With a footprint equivalent to one-half that of standard SC connectors, the LC connector is fast
becoming the answer to the market's demand for increased optical port density. Utilizing the connector's small size and rugged design, the SMART
LC-MPO 48 patch panel supports up to 48 fibers in just 1U of rack space. LS SimpleViewTM patch cords must be used in order to benefit from the
advantages of the SimpleView system. These cords, described in greater detail in the Fiber Optic Cables and Cords section, feature a duplex fiber
cable and single copper wire in a common jacket, and an LC duplex connector with an extra spring-loaded copper contact. Regular LC patch cords
can be used when SimpleViewTM scanning is not desired.
Products
Fiber Patch Panel - LC MPO 96(High Density)
Ultra high density – 96 fiber strands in 1U
Can be assembled with 1,2,3 or 4 cassettes
Cassettes sold separately
Supports OM-3 Multi-Mode applications
SimpleViewTM Intelligent Solutions
Description
Fiber Patch Panel - LC MPO 48
Comprises 24 duplex LC adapters at the front and 4 MPO adapters at the back
Fits 1U of rack space
Preassembled 24 MM LC adapters, 4 LC-MPO fan-outs (see below for additional polarity
information) and 4 MPO adapters
Rear metal MPO protective bracket
External 14-pins PatchView connector offering real a 'plug-and-play' panel
Pullout drawer enable ease of access to the fiber cables
Configurable rack mounting brackets allow for recessed panel mounting, enhancing cable
protection
113
SimpleViewTM Fiber MPO Patch Panel
Part Numbers & Physical Chracteristic
SimpleViewTM Intelligent Solutions
Description
Dimensions (mm)
Part Number
SimpleViewTM LC Fiber Patch Panel
44.0(H) x 482.6(W) x 240.0(D)
LS-IFPP-LC-XXX-YY
SimpleViewTM SC Fiber Patch Panel
88.0(H) x 482.6(W) x 320.0(D)
LS-IFPP-SC-XXX-YY
SimpleViewTM LC 8 x 8 Fiber Patch Panel
44.0(H) x 482.6(W) x 240.0(D)
LS-IFPP-LC 8 x 8-XXX
SimpleViewTM LC MPO Fiber Patch Panel
44.0(H) x 482.6(W) x 240.0(D)
LS-IFPP-LC-MPO-XXX-YY
XXX Denotes SM(Single Mode), MM1(Multi Mode OM1), MM3(Multi Mode OM3)
YY Denotes Cores : 24=24cores, 48=48cores, 96=96cores
Specifications
Panel rack mounting
1U 19 (IEC 60297)
Product weight
3.7 Kg / 8.1 lb
Materials
Zintec - powder coated black RAL 9011
Number of trays
2 discrete (1U total height)
Capacity
48 fibers max (LC)
Connector system
LC, MT-RJ, SC
Cable management
Internal
Signal voltage
5V dc
Signal current
2 mA max (EN60950:2000)
Connector Specification
Sleeve material
Singlemode - ceramic / Multimode-phosphor bronze
Typical insertion loss, dB
Singlemode-0.2 / Multimode-0.3
Environmental
114
Operating temperature range
-10
Operating humidity range
≤ 95% relative humidity non-condensing
- +60
Standards
EN 6008-2-2, IEC 68-2-27, IEC 68-2-6,
IEC 68-2-14, IEC 68-2-3, ISO/ IEC11801:2002
SimpleViewTM Patch
Intelligent
Cord
Solutions
(Copper & Fiber)
Products
Fiber MPO Patch Cord
•Nine-wire, 100, patch cords for SimpleViewTM applications
•Data signals transferred over four pairs, 9th wire transfers SimpleViewTM scanning signals
•pin 0 unused, pin 9 used for the SimpleViewTM scanning signal
•Compatible with all RJ-45 jack models (8 or 10 pins)
•Full Category 5e, and CAT 6 performance
•STP, SFTP, FTP and UTP models
•100% tested at factory
•The system is designed to conform to ANSI/TIA/EIA-568-B.2, ISO/IEC 11801 2nd edition
(2002) and CENELEC EN50173 (2002) for Category 6/Class E.
•The system is designed to support protocols running at up to 1000 Mbps, such as ATM 622
Mbps and Gigabit Ethernet.
SimpleViewTM Intelligent Solutions
•10-position RJ-45 plugs. Pins 1 to 8 used for data,
Fiber Patch Cord(LC) / Fiber Patch Cord(SC)
•MT-RJ duplex patch cords with a
SimpleViewTM scanning wire for SMART MTRJ 48 and 96 panels
•Available in MM 50/125 OM3, MM 50/125,
MM 62.5/125 and SM 9.3/125
Part Numbers
Description
Part Numbers
SimpleViewTM Unshielded Patch Cord
LS-IPC-UCXX-ZZZ
SimpleViewTM Shielded Patch Cord
LS-IPC-SCXX-ZZZ
SimpleViewTM LC Fiber Patch Cord
LS-IFPC-LC-YYY-ZZZ
SimpleViewTM SC Fiber Patch Cord
LS-IFPC-SC-YYY-ZZZ
SimpleViewTM MT-RJ Fiber Patch Cord
LS-IFPC-MTRJ-YYY-ZZZ
XX Denotes 5e(Cat.5e), 6(Cat.6), 6A(Cat.6A) / YYY Donotes SM(Single Mode), MM1(Multi Mode OM1), MM3(Multi Mode OM3) /
ZZZ Denotes 005(0.5m), 030(3m), 050(5m), 100(10m) etc
Technical Details-Copper
Environmental-Fiber
Cable Dimensions
2.6 × 3.7 mm ( +0/0.1) mm
Cable Weight
14.8 kg/km
Min Bending Radius - Short Team
Loaded : 45mm Installed : 35mm
Maximum Tensile Strength
300 N
Maximum Compressive Load
100 N/cm
Flexing
1,000 cycles
Operating Temperature
-25
to +75
Storage Temperature
-25
to +75
115
SimpleViewTM Accessories
Products
Scanner Attachment Cords
Scanners are connected to patch panels with Scanner Attachment Cords.
SimpleViewTM Intelligent Solutions
•Supplied in various lengths
•Scanner Attachment Cords needed depend on the type of SimpleViewTM Patch Panels to
be connected and whether the Splitter is used
•Round Flat Attachment Cords are available in UTP and STP models
•Flat Attachment Cords are available in UTP models
Control Pad
SimpleViewTM Control Pad is connected to a SimpleViewTM Scanner via the Control Pad Port.
Using the Control Pad the technician is guided through the process of connecting and
disconnecting the cables to complete the links defined in the system. The three functions that
are activated by the Control Pad are:
•LED SCAN : This is an automatic LED SCAN that causes the LEDs of the ports to light in
the sequence that they are connected
•Reconfiguration on /pending: When a work order or link task is sent to a scanner, the
Reconfiguration LED on the connected Control Pad/s starts to blink, indicating that there is
a link task pending
•Manual Scan : The ports on the Patch Panels can be manually scanned or browsed by first
activating the Manual Scan buttons on the Control Pad and then moving to the required port
using the directional buttons
Part Numbers
Description
Part Numbers
Scanner Attachment Cords - Round Type
LS-AC-Round-XXX
Scanner Attachment Cords - Flat Type
LS-AC-Flat-XXX
SimpleViewTM Control Pad
LS-Control Pad
XXX Denotes 010(1m), 025(2.5m), 050(5m) etc
Technical Details
Standards compliance
Safety
UL 60950, EN 60950
EMC
EN-55022, FCC Part 15 Class A, EN-55024
Scanner
Connector RJ-45 socket
Interface
Cable with two RJ-45 connectors on either side.
One connects to the Control Pad and one to the
CONTROL PAD PORT on the Front Panel of
the Scanner
LEDs
116
LED SCAN
Stays lit while Automatic Scan is in process
RECONFIG ON /
PENDING
MANUAL SCAN
Blinks when Reconfig. Is pending.
Stays lit while work is in progress
Stays lit while Manual Scan is in process
SimpleViewTM Management
Intelligent Solutions
Software
Description
The SimpleViewTM Software forms the user interface and is accessed by System Administrators and Network Technicians via the web. The system
automatically provides complete link information in a graphical format, providing full end-to-end visibility, automatically updation in real time as
changes occur SimpleViewTM drastically speeds up and simplifies daily network provisioning, maintenance and security providing Network Managers
SimpleViewTM Intelligent Solutions
with full visibility and control of the network and its assets.
Structure
Technical Details
Technical Details
•Real-time connection troubleshooting
•Location-based deployment and provisioning
•Reduced connection mean-time-to-repair and disaster
•Remote moves, adds and changes
recovery
•On-site connection security compliance
•Network infrastructure utilization and optimization
•Secure VLAN access
•Maintaining reporting and forensics
•Physical infrastructure anti-tampering
•Physical infrastructure visibility
Part Numbers
Description
Part Number
SimpleViewTM Software
LS-CMS-XXXXX
SimpleViewTM Software + SQL
LS-CMS-SQL-XXXXX
SimpleViewTM Software Additional
LS-CMS-ADD-XXXXX
SimpleViewTM Software CAD Module (Without MapGuide)*
LS-CMS-CAD-MapGuide
XXXXX Denotes 01000 (1,000Port), 05000(5,000port), 10000(10,000Port) etc
Ⓡ
* CAD Module requires Autodesk MapGuide
117
SimpleViewTM Site Pro
Description
LS’s application for installation on PDA devices, is a vital tool for IT professionals and infrastructure engineers on the move, bringing the SimpleViewTM‚
SimpleViewTM Intelligent Solutions
advanced capabilities and an array of other essential tools out into the field.
Application
Features
•Display of user’s specific tasks in specific location
•Automatic guidance through user’s assigned tasks
•Accurate display of devices and their complete links
(from switch to server) affected by any work done
•Online connection with LS’s SimpleViewTM scanning devices
•Real-time error tracking, resolution and documentation
•Task management including the ‘Skip’ function
•Online messaging - receiving / sending notes
Server Requirements
Minimum Hardware
Pentium processor running at least 800 MHz
1000 MB + RAM
20 GB hard disk space
Recommended Hardware
Dual Pentium 4 processor running at 2600 MHz
1024 MB RAM(or more)
40 GB+ hared disk space
Software
Windows 2000 family(Windows 2003 server family recommended)
(Microsoft Internet Explorer 6 recommended)
Microsoft SQL 2000(standard/Enterprise edition recommended)
IIS 5(or higher)
MSMQ - Microsoft message queing system
Client Minimum Requirements - Software
Any Microsoft based system(Win 95, 98, ME, NT, 2000, XP etc.)
Microsoft Internet Explorer 5.5 with service pack1
(with signed ActiveX and cookie support)
118
SimpleTM Warranty
Installation Manual for the tool-less M/J
Reference
LS SimpleTM Warranty
Warranty
TM
The Simple range of solutions is supported by a SimpleTM comprehensive warranty
•25 Year Application and product warranty
•Product replacement for any approved claims, installed and re-tested, with all field labour costs included under warranty
•Installed and registered by an approved SI
•Warranty applied to the project / location can be sold with the building by the end user
TM
Reference
Warranty Process
120
LS SimpleTM Warranty
Warranty
LS C&S warrants to the End User that the System in its installed state will meet the Specifications in force at the time of installation for the duration of the
Warranty Period.
LS C&S warrants to the End User that the Products, which comprise thd System, will be free from defects in materials and workmanshio design for the
duration of the Warranty Period.
Applications Assurance Warranty
LS C&S warrants to the End User that, for the duration of the Warranty Period, the System will be free from defects, which prevent a full stop after operation.
Applications specified by recognised standards or user forums that use the Applicable Structured Cabling Srandards;
How to Apply for the Warranty
TM
The Registration document must be completed by both the LSI and the End User and sent to LS C&S within 30 days of completion of the installation of the
System.
Reference
Applications introduced in the future by recognised standards or user forums that use the Applicable Structured Cabling Standards; and any other
applications Specified in writing by LS C&S.
Installation of the System
The warranty shall only apply if the Sysem has been properly installed and tested by LSI.
Alterations to the System
Any alteration, repair, modification and/or addition to a warranted System will invalidate the warranty, unless it is tested and registered with LS C&S by LSI.
Any replacement or additional Product used is warranted free from defects in materials and workmanship for the remainder of the Warranty Period
applicable to the System unless a new System is installed in which case a new LS System warranty will be raised.
Claims Procedure
The End User shall notify LS C&S or LSI that originally installed System within five working days of the discovery of any alleged defect in the System or
Product, but in no event later than the expiration of the Warranty Period. The LSI shall ascertain the nature of the alleged defect.
The End User, if so requested, should allow LS C&S, LSI or their authorised representatives free access to the premises on which the allegedly defective
System of Product is located for the purpose of inspection. No Product may be removed from the System without LS C&S's prior authorisation.
The End User shall, on request, make available to LS C&S copies of the test reports.
What LS C&S will do
If LS C&S is satisfied, after inspection or otherwise, that the System and/or Products do not comlpy with the warranty then, at LS C&S's discretion
•The defective Products will be replaced and installed free of charge
•The defective Products will be repaired at the premises at which they are located or at the manufacturer's premises (as necessaty); or
•The purchase price of the defective Products will be refunded.
If any Product has been upgraded, LS C&S shall have the option to use such a product to satisfy its obligations providing that the functionality and
performance of the upgraded product is at least equal to that set out in the specification for the replaced Product.
LS C&S's Liability to you under this Warranty
The warranty shall only be applicable if;
•New Products were used in the System at the time of installation
•The defect was not caused by incorrect of negligent handling, disregard of any reasonable instruction given by LS C&S, any abnormal use (including the use
of unsuitable of defective equipment in connection with the Products), over-loading, unreasonable wear and tear or any other fault by End User, its
subcontractors, servants or agents; and
•The defect was not caused by any other external act or omission or circumstance beyond LS C&S's control (including but not limited to Act of God) occurring
after delivery.
LS C&S will not be liable for special, indirect, incidental or consequential damages (regardless of the form of action), including but not limited to damages for
loss of profits, data, time, revenues of the like, nor shall LS C&S be liable for any claims or damages arising out of or connected with the warranty of the
manufacture, sale, delivery or use of the defective products. This clause shall survive failurer of an exclusive remedy.
THE WARRNATIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS OF IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Nothing in these conditions shall purport to exclude or restrict any liability, the exclusion or restriction of which is prohibited by law.
Nothing in these conditions shall affect the statutoty rights of the consumer.
121
Seat the wires into the wire slots according to the
wiring code
Slide the wiring block down the Jack housing
guide, covering the IDC terminals. Then push the
cable into the cable holder
Trim the excess wires by using a diagonal cutter.
Close the wings
Please tie the around the shielding base
and cut the excess after tighten up
Seat the wires into the wire slots according to the
wiring code
Trip the excess wires by using a diagonal cutter
TM
Reference
Installation Manual for the tool-less M/J
Push down the cap using fingers
122
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement