Sea Gull Lighting 59216LE-782 Installation Guide

INSTALLATION AND SAFETY INSTRUCTIONS
FOR YOUR SAFETY
WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU
ARE WORKING ON IS SHUT OFF. EITHER THE FUSE REMOVED
OR THE CIRCUIT BREAKER OFF .
ASSEMBLY
STEP 1:
Remove center cover (B) by squeezing cover together and pulling
out of tabs (C).
STEP 2:
GENERAL
You do not need any special tools to install this fixture. Be sure to follow the steps in the order given. Read instructions carefully. If you are
unclear as to how to proceed, consult a qualified electrician.
NOTE: In order for this lighting fixture to operate properly the
buildings electrical system must be grounded. If you are
unclear as to how to proceed, consult a qualified electrician.
NOTE: FOR FIXTURES PROVIDED WITH 75˚C OR 90˚C SUPPLY
WIRE WARNING ONLY-(THESE WARNINGS ARE PROVIDED ON
THE U.L. LABEL AND ON THE FIXTURE CARTON): RISK OF
FIRE. MOST DWELLINGS BUILT BEFORE 1985 HAVE SUPPLY
WIRE RATED 60˚C. CONSULT A QUALIFIED ELECTRICIAN
BEFORE INSTALLING.
7/8" WIRE EXIT
Remove 7/8” diameter wire exit plug and oval mounting knock-outs
by taking a screwdriver and punching out plug and knock-outs from
back side of fixture pan (A).
Do not install on a ceiling that would cause the lift and shift
mechanism to disengage (ie. slope ceiling, drop
ceiling etc.)
STEP 3:
Install (one) end cap (O) onto fixture pan (A). secure in place with
cap nut (E).
IF SUPPLY WIRES ARE LOCATED WITHIN 3" OF
BALLAST, USE WIRE RATED FOR AT LEAST 90˚C.
TAB (C)
FIXTURE PAN (A)
BALLAST
MOUNTING HOLE
CENTER COVER (B)
FIGURE 1
Installation And Safety
Instruction
HC-976 082206
Line art shown may not exactly match the fixture enclosed.
However, the installation instructions do apply to this fixture.
Fill In Item Number On Carton And
File This Sheet For Fixture Reference.
ITEM#_______________
INSTALLATION
HC-976
IF SUPPLY WIRES ARE LOCATED WITHIN
3" OF BALLAST, USE WIRE RATED FOR
AT LEAST 90˚C
STEP 1:
Determine exact location on ceiling for fixture placement.
STEP 5:
GROUNDING INSTRUCTIONS: The green grounding screw is to
be inserted into the hole with two raised dimples provided on the
fixture pan. Wrap the ground wire from the fixture (if supplied) and the
ground wire from the outlet box (bare metal or green insulated
wire) around the green grounding screw on the fixture pan. If
uninsulated wire is on the chassis, connect the ground wire from
the fixture (if supplied) and the outlet box to it using a small wire
connector (not supplied).
STEP 2:
Feed the black and white ballast wires through the 7/8” wire exit hole
of the fixture pan (A).
STEP 3:
Mount fixture to ceiling. When mounting to drywall use molly bolts.
When mounting to ceiling joists use 1 1/4“ screws. (recommended)
NOTE: Underwriters Laboratories (U.L.) does not require all fixtures to
have ground wires. These fixtures still meet all U.L. specifications. The
listing mark of Underwriters on the product identifies products
manufactured under its listing and Follow-Up Service Programs.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE
POWER SUPPLY WIRES.
FINAL ASSEMBLY
STEP 4:
WIRING:
Take note of the color of the wire(s) on your fixture. Identify
which group your fixture wire(s) falls into and connect the wires
according to the directions below:
Make sure no bare wires can be seen outside wire connectors.
STEP 1:
Install center cover (B) over fixture by squeezing center cover (B)
together and insert under tabs (C).
STEP 2:
Install lamps.
STEP 3:
Raise diffuser to fixture pan (A) and slide diffuser to meet up with
end cap (D).
STEP 4:
Install retaining end cap (D) and secure with cap nut (E).
GROUP A: CONNECT TO BLACK
HOUSE WIRE
GROUP B: CONNECT TO WHITE
HOUSE WIRE
BLACK
WHITE
*PARALLEL WIRE (ROUND & SMOOTH)
*PARALLEL WIRE (SQUARE & RIDGED)
*NOTE: When parallel wire is used, the tracer wire is square shaped
or ridged, and the less tracer wire is round in shape or smooth. (Seen
best when viewed from wire end.) To separate wires, grasp the ends
of each wire and pull apart.
A. Place black wire from fixture evenly against black wire from the
outlet box and twist together the bare parts of the metal.
B. Fit a wire connector (not supplied) over the twisted wires and
screw the connector clockwise until you feel a firm connection.
C. Try gently to pull the connector off the wire. If you can pull the
connector off, carefully re-do steps A and B, as above, and check
again for a firm connection.
D. Connect the white wire from the fixture to the white wire from the
outlet box in the same manner.
NOTE: IN ORDER FOR THIS LIGHTING FIXTURE TO OPERATE
PROPERLY, THE BUILDING’S ELECTRICAL SYSTEM MUST BE
GROUNDED. IF YOU ARE UNCLEAR AS HOW TO PROCEED,
CONSULT A QUALIFIED ELECTRICIAN.
CLEANING
To clean, wipe fixture body with a soft cloth. Clean glass with a mild
soap. Do not use abrasive materials such as scouring pads
powders, steel wool, or abrasive paper.
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order
replacement parts. All parts for this fixture can be ordered from place
of purchase. Be sure to use exact wording from illustration when
ordering parts.