1 2 3 4 5 6 8" METAL STUD WALL MECHANICAL DUCT, SEE MECHANICAL SHEETS FOR SIZE 5/8" TYPE 'X' GYP. BOARD BOTH SIDES E E VCBO ARCHITECTURE 524 SOUTH 600 EAST SALT LAKE CITY, UT 84102 Phone: (801) 575-8800 (801) 531-9850 Fax: WWW: www.vcbo.com 1 1 SCHEDULED QUARTZ QZ1 SCALE: 1 1/2" = 1'-0" 5/8" GYP. BOARD, BOTH SIDES AND TOP 0' B2 4' - 0" U.N.O. 5/8" GYP. BOARD, BOTH SIDES AND TOP PROVIDE (1) 1 1/4" DIA. OPENING IN TUBE STEEL FOR ELECTRICAL CONDUIT, TYP. 5'-0" TO FLOOR 3 1/2"X6"X3/16" PLATE ANCHOR INTO FLOOR WITH (2) 1/2" DIA. ANCHORS, FULL PAN WELD AT HSS SUPPORTS SCHEDULED FLOORING OVER CONCRETE SLAB 3"X3"X1/4" HSS, FULL HEIGHT OF WALL, AT ENDS AND MIDPOINT OF WALL, 3/8" BOLTS @ 6" O.C. VERTICALLY B2 A810 SEMI-RECESSED FIRE EXTINGUISHER CABINET HAND HELD FIRE EXTINGUISHER 5'-0" TO FLOOR 3 5/8" METAL STUD FRAMING @ 16" O.C., 1 STUD EACH SIDE OF TUBE STEEL SCHEDULED METAL STUD W/ 5/8" GYP. BOARD BOTH SIDES AND IN RECESS SEE MANUFACTURER FOR ROUGH OPENING 4' - 0" U.N.O. PROVIDE (1) 1 1/4" DIA. OPENING IN TUBE STEAK FOR ELECTRICAL CONDUIT, TYP. CABINET DOOR 6" 1'-0" 1'-6" COMPOSITE FLOOR DECK OR STEEL ROOF DECK. REFER TO STRUCTURAL DRAWINGS SCHEDULED METAL STUD W/ 5/8" GYP. BOARD BOTH SIDES AND IN RECESS METAL DEFLECTION TRACK. GAUGE TO MATCH GAUGE OF WALL STUD. FASTEN TO DECK WITH POWDER-DRIVEN FASTENERS AT COMPOSITE DECK AND SHEET METAL SCREWS AT METAL DECK ONLY RECESSED FIRE EXTINGUISHER CABINET HAND HELD FIRE EXTINGUISHER ACOUSTICAL INSULATION IN DECK FLUTES 1/2" 3"X3"X1/4" HSS, FULL HEIGHT OF WALL, AT ENDS AND MIDPOINT OF WALL, 3/8" BOLTS @ 6" O.C. VERTICALLY A810 NOTE: COORDINATE MODEL W/ DEPTH OF STUDS NOTE: COORDINATE MODEL W/ DEPTH OF STUDS 1/2" REVEAL SEE MANUFACTURER FOR ROUGH OPENING SCHEDULED QUARTZ QZ1 D SHAFT DETAIL E5 REVEAL CONTINUOUS 16 GAUGE METAL PLATE CABINET DOOR CONTINUOUS 16 GAUGE METAL PLATE. REFER TO DETAIL 'A' FOR ATTACHMENT ACOUSTICAL SEALANT BOTH SIDES CONTINUOUS SEALANT AT PERIMETER 1' - 0" ATTACH GYPSUM BOARD TO METAL STUDS AND NOT TO METAL DEFLECTION TRACK ACOUSTICAL SEALANT BOTHD SIDES METAL RUNNER TRACK NESTED INTO DEFLECTION TRACK TO MAINTAIN MIN 1 1/2" GAP. GAUGE TO MATCH GAUGE OF WALL STUDS 3 5/8" METAL STUD FRAMING @ 16" O.C., 1 STUD EACH SIDE OF TUBE STEEL ACOUSTICAL INSULATION PARTITION TYPE AS INDICATED ON THE FLOOR PLANS STEEL BEAM, SEE STRUCTURAL DETAILS WELD TUBE TO FLOOR ANGLE SEE MANUF. ACOUSTICAL INSULATION ADDITIONAL COMPONENT NO X SEE MANUFACTURER SEE MANUFACTURER SEE MANUF. FOR ROUGH OPENING FOR ROUGH OPENING A FOR R.O. FOR R.O. FOR ADDITIONAL SIMILAR NOTES NOT SHOWN HERE, REFER TO DETAIL 'A' TO THE LEFT PERPENDICULAR TO METAL DECK FLUTES B PARALLEL TO METAL DECK FLUTES SCHEDULED BASE, BOTH SIDES SCHEDULED FLOORING OVER CONCRETE SLAB E6 LOW WALL SECTION1 D3 SCALE: 1 1/2" = 1'-0" FLOOR INFILL AREA FIRE EXTINGUISHER CABINET D4 SCALE: 1 1/2" = 1'-0" 0' 6" 1'-0" FIRE EXTINGUISHER CABINET NON-RATED ACOUSTICAL PARTITION HEAD DETAILS D5 SCALE: 1 1/2" = 1'-0" 1'-6" 0' 6" 1'-0" SCALE: 3" = 1'-0" 1'-6" 0' 6" 1'-0" 1'-6" 0' 1" 3" 6" 9" CONDUIT OR PIPING NOTES: CROSS BRACING 2" MAX. METAL STUDS AT TYPE 'A' BACKING PLATES METAL STUDS AT TYPE 'B' BACKING PLATES SIMILAR TO UL CAJ8101 C (3) 3/4" #10 LOW PROFILE PAN HEAD SHEET METAL SCREWS AT EACH STUD, TYP. TYPE 'A' BACKING PLATES: C1 LOW WALL SECTION C2 SCALE: 1 1/2" = 1'-0" CONDUIT PENETRATION DETAIL C3 SCALE: 3" = 1'-0" 0' 6" 1'-0" (3) 3/4" #10 LOW PROFILE PAN HEAD SHEET METAL SCREWS AT EACH STUD, TYP. TYPE 'B' BACKING PLATES: 0' 1" 3" 6" FOR ADDITIONAL SIMILAR NOTES NOT SHOWN HERE, REFER TO DETAIL 'A' TO THE LEFT PARTITION TYPE AS INDICATED ON THE FLOOR PLANS A BACKING PLATE SCHEDULE PERPENDICULAR TO METAL DECK FLUTES B SCALE: 3" = 1'-0" 9" 0' SCHEDULED ROOF 1 METAL FURRING @ JOIST WEB W/ 5/8" GYP. BOARD EACH SIDE A810 A1 3"X3"X1/4" TUBE STEEL, FULL HEIGHT OF WALL, AT ENDS AND MIDPOINT OF WALL, 3/8" BOLTS @ 6" O.C. VERTICALLY A810 STEEL BEAM, PAINTED WHEN EXPOSED SCHEDULED CEILING SYSTEM, SEE CEILING PLANS 1/2" MAX. 5/8" TYPE 'X' GYP. BOARD 16 GA. METAL TRACK, PAINTED 1" CONTROL JOINT @ 30'-0" MAX SPACING 3 5/8" METAL STUD FRAMING @ 16" O.C., 1 STUD EACH SIDE OF TUBE STEEL BATT INSULATION 1" SCHEDULED WALL SCALE: 6" = 1'-0" 0' 6" 1'-0" 2" STUD FRAMED CONTROL JOINT 0' 1" 2" 0' 1" TO WHEN DIMENSION EXCEEDS 3" INSTALL CRIPPLE STUDS IN CORNER 4" 1" 3" 6" 0' 1. ALL FIRE DAMPERS TO BE INSIDE WALL. 2. CUT GYP. BOARD TIGHT TO DUCT. (MAX. GAP OF 1/4") SEAL AS REQUIRED. 3. IF DUCT IS TO BE INSULATED, DO NOT RUN INSULATION THROUGH WALL. FLARE INSULATION ONTO FACE OF WALL AROUND DUCT ON BOTH SIDES OF WALL AND SEAL TO FACE OF WALL WITH INSULATION MASTIC. DISTANCE TO FIRST SCREW IN GYP. BOARD 1' - 7 1/2" CONCRETE FLOOR SLAB - REFER TO STRUCTURAL DRAWINGS A3 SCALE: 3" = 1'-0" TYP. DUCT OPENING IN RATED WALL SCALE: NOT TO SCALE 6" 9" B A5 A810 RECESSED A/V MOUNTING BRACKET, SEE ELECTRICAL 3 5/8" METAL STUD @ EACH SIDE OF MONITOR BRACKET NON-RATED PARTITION BASE DETAIL1 1'-6" 0' 1" 3" 6" 1/2" 9" METAL CORNER BEAD, TYP. METAL STUD FRAMING, SEE SCHEDULED WALL 3 5/8" METAL STUD @ EACH SIDE OF MONITOR BRACKET A6 A810 2 A5 SCALE: 3" = 1'-0" 3 RECESSED A/V MOUNTING BRACKET, SEE ELECTRICAL 0' 1" 3" 6" 3 5/8" METAL STUD FRAMED WALLS A 1/2" 5/8" TYPE 'X' GYPSUM WALLBOARD (TYP.) 5/8" GYPSUM WALLBOARD 3 5/8" METAL STUD FRAMED WALLS 9" Job # 13375 CAD File Drawn Author Checked Checker Date OCTOBER 28, 2013 Owner # Ins. # TYPICAL INTERIOR FRAMING DETAILS SCHEDULED BASE SOUND BATT INSULATION DIGITAL SIGN DISPLAY MOUNT PLAN SCALE: 1 1/2" = 1'-0" 4 Description ADDENDUM 01 EDGE OF WALL (BEYOND) METAL STUD FRAMING, SEE SCHEDULED WALL TYPICAL ELECTRICAL DEVICE DETAIL Date 11.01.13 MONITOR, SEE ELECTRICAL PLANS FOR SIZE 5/8" TYPE 'X' GYPSUM BOARD (TYP.) NOTE: ILLUSTRATION DOES NOT SHOW WALL FINISHES, TILE, PLASTIC LAMINATE, OR OTHER FINISHES A4 Rev # 1 VINYL WALL GRAPHIC TO WRAP WALL FIRE SAFING MATERIALS PARTITION SLIP JOINT TYPICAL 3" 1'-0" LOCATE 'J' BOXES ON OPPOSITE SIDES OF STUD AND FILL CAVITIES W/ BATT INSULATION TO PREVENT SOUND TRANSMISSION SIMILAR TO UL CAJ8101 1" 6" ISOLATE BACK-TO-BACK 'J' BOXES W/ 1 1/2" X 16" X CONT. POLYISO RIGID INSULATION BOARD TO PREVENT SOUND TRANSMISSION METAL STUDS 0' EDGE OF WALL (BEYOND) SCALE: 3" = 1'-0" 9" NOTES: 2" DO NOT OVER TIGHTEN SCREWS, GENERAL CONTRACTOR TO ENSURE TOP CHANNEL SLIPPAGE 1 B5 FOR STEEL STUD WALLS USE FC-8019 1 HR. APPLICATION 5/8" GYP. BOARD ON METAL STUD, DO NOT FASTEN INTO TOP CHANNEL A1 9" METAL CORNER BEAD, TYP. 18 GA. METAL SLOTTED OVERSIZED CHANNEL 11/6/2013 2:16:23 PM WALL"Y" BRACING DETAIL1 SCALE: 1 1/2" = 1'-0" 4" METAL DECK A B4 SCALE: 3" = 1'-0" 1'-6" FIRE SAFING REQUIRED AT ALL RATED WALLS, FILL IN DECK FLUTES, SOUND BATT INSULATION AT ALL OTHERS 3" NOTE: FIRE SEAL STUD WALL AROUND STEEL JOISTS AND BEAMS B3 6" SCALE: 1 1/2" = 1'-0" LOW WALL REINFORCEMENT 1' - 0" B2 1' - 0" SLIP JOINT AT BEAM / JOIST 6" B1 ACOUSTIC SEALANT FULL DEPTH OF GYPSUM BOARD. BOTH SIDES OF WALL AT OPEN WEB JOIST 3' - 0" (VERIFY W/MONITOR) AT STEEL BEAM SCHEDULED WALL 1 HOUR OR NON-RATED 3/4" METAL RUNNER TRACK. ATTACH TO DECK WITH POWDER-DRIVEN FASTENERS AT 24" OC AND 2" FROM EACH END 1' - 7 1/2" B 6" A1 ACOUSTIC INSULATION AS REQUIRED BY PARTITION TYPE 3 5/8" 22 GA. STUD DIAGONAL BRACING @ 48" O.C. STAGGERED. ANGLED APPROXIMATELY 45° FROM TOP OF WALL 45.0 0° R-13 BATT INSULATION BOTH SIDES OF JOIST/BEAM 5/8" GAP SEE WALL TYPE 3 1/2"X6"X3/16" PLATE, ANCHOR INTO FLOOR WITH (2) 1/2" DIA. OFFSET ANCHORS, FULL PAN WELD AT TUBE STEEL SUPPORTS OPEN WEB STEEL JOIST 6" MONITOR, SEE ELECTRICAL PLANS FOR SIZE. FOR PARTITION TYPE 3' - 3" (VERIFY W/MONITOR) 3 5/8" METAL STUD FRAMING @ CORNER 3" SEE FLOOR PLAN 1 5/8" TYPE 'S' SCREWS @ 24" O.C. SCHEDULED STEEL STUD 1/4" MIN - 1/2" MAX METAL CORNER BEAD, TYP. OVER 5/8" GYP. BOARD 1" WALL EXTENDS TO METAL DECK FLOOR OR ROOF STRUCTURE FIRE SAFING @ DECK FLUTES @ FIRE RATED WALLS, SOUND BATT INSULATION AT ALL OTHER LOCATIONS PARALLEL TO METAL DECK FLUTES NON-RATED PARTITION HEAD DETAILS1 C5 SCALE: NOT TO SCALE 1'-6" C METAL RUNNER TRACK NESTED INTO DEFLECTION TRACK TO MAINTAIN MIN 1 1/2" GAP. GAUGE TO MATCH GAUGE OF WALL STUDS TYPE 'B' BACKING PLATE SHALL SUPPORT THE SAME ITEMS AS TYPE 'A' BACKING PLATE BUT USE WHERE APPEARANCE IS THE MAIN CONCERN SUCH AS LOBBIES AND OTHER HIGH DESIGN AREAS. - AT DOOR STOPS AND BUMPER RAILS - AT TOILET ACCESSORIES, MIRRORS, COAT HOOKS, ETC. - AT ALL UPPER WALL HUNG CABINETS - AT ALL BASE CABINETS - AT ALL FULL HEIGHT CABINETS - AT WALL MOUNTED ADJUSTABLE SHELVING - AT ALL WALL MOUNTED HANDRAILS PACK WITH FIRE SAFING MATERIALS AND FIRE CAULK CONTINUOUS 16 GA. METAL PLATE. REFER TO DETAIL 'A' FOR ATTACHMENT ATTACH GYPSUM BOARD TO METAL STUDS AND NOT TO METAL DEFLECTION TRACK 5' - 0" 6" METAL STUDS BEHIND GYP. BOARD NOTCH STUD RETURN TO ALLOW PLATE TO PASS INSIDE STUD FLANGE METAL DEFLECTION TRACK. GAUGE TO MATCH GAUGE OF WALL STUD. FASTEN TO DECK WITH POWDER-DRIVEN FASTENERS AT COMPOSITE DECK AND SHEET METAL SCREWS AT METAL DECK ONLY 2" MAX 3' - 0" 1. CUT GYP. BOARD TIGHT TO DUCT. (MAX. GAP OF 1/4") SEAL AS REQUIRED. 2. THROUGH CONCRETE WALLS USE W-J-1116. 3. THROUGH GYP. BOARD WALL USE W-L-1018. COMPOSITE FLOOR DECK OR STEEL ROOF DECK. REFER TO STRUCTURAL DRAWINGS TYPE 'B' BACKING PLATE: 16 GAUGE X 6" HIGH BENT METAL PLATE ATTACHED TO WEB PORTION OF METAL STUDS TYPE 'B' BACKING PLATE TYPE 'A' BACKING PLATE: 16 GAUGE X 6" HIGH CONTINUOUS METAL PLATE 3930 WEST PARKWAY BLVD. WEST VALLEY, UTAH CONSTRUCTION DOCUMENTS - BID SET TYPE 'A' BACKING PLATE INTERMOUNTAIN HEALTHCARE WIDE FLANGE BEAM INTERMOUNTAIN HEALTHCARE CREEKSIDE PROVIDE BACKING PLATES AS INDICATED ON THE DRAWINGS OR WHERE NOT INDICATED, ACCORDING TO THE FOLLOWING SCHEDULE. REFER TO DETAILS ELSEWHERE IN THE SET OF DRAWINGS FOR THE SUPPORT OF WALL MOUNTED ITEMS IN EXCESS OF 200 POUNDS A6 DIGITAL SIGN DISPLAY MOUNT SECTION SCALE: 1 1/2" = 1'-0" 5 6 A810
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement