Product Catalogue 3 CABLE CONNECTION TECHNIQUE Single Connectors Your Partner for Connection Technique Since 1928 the name ARCUS equals quality and reliability in cable connections and safety products. The ARCUS ELEKTROTECHNIK ALOIS SCHIFFMANN GMBH is a highly specialised industrial enterprise in which high-quality products are designed and produced for the worldwide market. Our product range includes: • • • • • • • • Connectors and tools for underground cables Overhead line clamps Earthing and short circuiting devices with cables and bars Lance earthing devices for outdoor switchgear up to 80 kA/0.5 s and 63 kA/1 s High voltage detectors for nominal voltages up to 380 kV Detectors and phase comparators for encapsulated switchgear Compression material and compression tools Devices for current tapping and power supply Always in the centre of our activities: Our clients. Our top aim is their complete and long-term satisfaction! Highly qualified and motivated employees in our company in Munich and in our sales offices are the main condition for a successful conversion of customers' requirements. During the long history of our company we have always understood some complex requirements of our customers as a challenge to be met. In many cases the result of technical cooperation with business partners are products with an extraordinary place on the world market. Technical know-how and the latest production techniques insure long term quality and reliability of our products and permit to keep the place of our company in Germany. Availability by phone: For queries concerning products and delivery time, and to place an order by phone, we are available as follows: +49 (0)89/436 04-0 Monday - Thursday: 8:00 am-12:00 noon and 12:30 pm-16:00 pm Friday: 8:00 am-12:00 noon Information concerning this catalogue: All rights reserved for copying of any kind. All dimensions and pictures are not binding. We permanently strive to improve products and reserve the right to change design, dimensions or material. Cable cross sections mentioned refer to DIN VDE 0295. Contents General List of Type Numbers Foreword Introduction Technical information direct terminals Technical information transformer clamps and connection terminals 4 5 6 7 8 Branch Connectors Parallel branch terminals for control wires of cables with auxiliary wires Parallel tap-off clamps Insulation covers for parallel tap-off clamps T-type tap-off clamps Insulation covers for T-type tap-off clamps Parallel tap-off clamps for sectorial mains conductors Parallel insulation-piercing tap-off clamps, insulated Parallel insulation-piercing tap-off clamps 9 10 11 12 13 14 15 16 Connection clamps for earth and neutral conductors 18 Terminals Aluminium flat direct terminals for connection of cable conductor ends to circuit bars or flat bars 19 V-type direct terminals for connection of cable conductor ends with V-shaped plates 20 Transformer clamps and connection terminals for transformer bushings DT 630 and DT 1000 21 Accessories Contact and pressure plates Separating wedges 22 22 Installation Tools Installation Tool Box for Cables, Insulated Tools Insulated Tools 23 26 3 List of Type Numbers General Type Number Page 105-198 105 105 105 105 105 105 106 106 106 106 106 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 4 027 028 029 030 037 039 047 050 052 054 057 001 003 004 006 007 027 028 042 043 050 051 060 061 062 063 077 080 081 087 090 091 094 095 096 097 098 101 102 118 119 120 127 150 151 154 155 156 157 Type Number Page 105-198 21 21 21 21 21 21 19 19 19 19 19 12 12 12 12 12 13 13 10 10 11 11 14 14 14 14 18 14 14 18 18 18 17 17 17 17 17 22 22 13 13 12 17 14 14 14 14 14 14 109 158 109 159 109 169 109 170 109 171 109 172 109 173 109 174 109 177 109 179 109 185 109 186 109 214 116 023 198 025 198 026 198 084 198 085 198 119 198 184 198 208 198 224 198 225 198 358 198 359 198 388 198 395 198 408 198 414 17 17 12 12 12 13 13 13 25 18 18 10 15 9 17 17 10 10 17 26 17 17 17 20 20 15 12 15 15 014 019 024 028 029 032 033 034 039 240 19 20 19 20 20 19 19 19 20 20 064 065 066 083 22 22 22 22 504 504 504 504 504 Page 615-620 206-298 206 206 206 206 206 206 206 206 206 298 Type Number 615 040 615 051 620 031 620 032 620 033 620 034 620 035 620 036 620 037 620 038 620 039 620 040 620 041 620 042 620 043 620 044 620 090 620 095 620 096 620 097 620 098 620 099 620 100 620 101 620 102 620 103 620 104 620 105 620 137 05 620 137 06 620 147 620 148 620 149 620 155 620 156 620 157 620 159 620 160 620 162 26 25 26 26 26 26 26 26 26 26 26 26 26 26 26 26 23 25 24 24 24 24 24 23 23 23 23 25 23 23 24 24 24 23 23 23 23 23 23 Foreword General Dear r eader! This catalogue will give you an overview of our range of single connectors and accessories. We have arranged these products in different groups to have them clearly structured and facilitate identification. All important details are listed in a table and supported by illustrations. In case of uncertainties how to find a product or how to select a suitable one, please contact us. You will find our contact details on the reverse side of this catalogue. ARCUS Schiffmann offers you a vast range of single connectors and accessories and furthermore will be pleased to support you in selecting the most suitable product. This s ervice i s a m atter o f c ourse f or u s! 5 Introduction General Why single connectors... It is daily business to connect a mains cable to a branch cable, especially in low voltage cable networks, for instance for a house service connection. In these cases the mains cable will be stripped at the installation point and the conductor insulation will be removed. Then branch conductors are connected with simple uninsulated tap-off clamps. Live installation of course is impossible under such conditions, so the mains cable and all connected consumers are without electric energy until the job is done. To minimise disturbance of consumers and to increase working safety for the electrician, insulated single connectors were developed, to be installed on insulated conductors. These connectors are provided with insulation-piercing teeth, cutting edges or screws which spare removal of insulation from conductors, and enable live installation when used with personal protection equipment and insulated tools, under observation of corresponding regulations. Required installation time is reduced significantly and at the same time safety of the jointer is increased. Furthermore impairment of cable and thus danger of damage (ingress of moisture, breaking of strands) is reduced because the insulation as conductor protection remains nearly intact. If y ou s hould n ot f ind t he p roduct t hat you l ook f or o n t he f ollowing p ages, please c ontact u s! 6 Technical information direct terminals As flat direct terminal with top part and bottom part for use in service boxes, cable distribution cabinets and substation terminal blocks (see page 19). 1. As V-type direct terminal for connection to circuit bars with V-shaped bar ends (see page 20). 2. Tin-plated direct terminals are suitable for connection of stranded copper conductors and solid or stranded aluminium conductors. All parts of the connection barrel in contact with conductors are grooved. RECOMMENDED TORQUE: Whilst pressure force (F) of flat direct terminals is bisected due to additional support of top clamp part, pressure force (F) of screws in V-shaped direct terminals will directly merge into contact force (FK). Please take our recommended torques for flat direct terminals and V-type direct terminals from the following table. Type Partitioning of pressure Effective contact pressure on conductor Recommended torque FK ~ 1/2 F 40 Nm (Screw M12) FK = F 25 Nm F FK FK F FK TESTING: ARCUS Direct Terminals are tested to DIN VDE 0220 part 1. 7 General DESIGN CHARACTERISTICS: ARCUS Direct Terminals are available in two designs: Technical information transformer clamps and connection terminals General Universal barrel shape for round and sectorial 3- and 4-core cables of 120-300 mm². Cross bracings prevent bending of terminal top when tightened excessively. Force fitted hexagons secure nuts reliably against coming loose and supersede counterholding during installation. (see picture 1, 3 and 4). Conical spring washers for compensation of creep deformation of aluminium conductors. Lateral stops save insertion of a dummy conductor into the second connection barrel when only one conductor is connected. Serrated connection areas improve contact transition between terminal and conductor. Long elongation screws provide stable contact conditions and a continuous current resistant connection by elastic elongation. Tin-plated surfaces allow usage on aluminium conductors as well as on copper conductors. Lateral noses prevent angular traction of top parts and escape of strands. Longitudinal-slotted connector barrel makes separate connection of transformer bolt and conductor unnecessary. → Overview of clamps on page 21 Number of Conductor Connections: 1 conductor 2 conductors Pict. 1 8 Pict. 2 3 conductors Pict. 3 4 conductors Pict. 4 Parallel branch terminals for control wires of cables with auxiliary wires 116 023 Reliable contact by piercing of main conductor insulation with cross cuttings. Separate installation of branch conductor from mains conductor to prevent shifting of live mains conductor during installation. 116 023 b a Branch Connectors Terminal parts secured against torsion to each other. Material Connector Electrolytic copper Contact screw (mains) Copper alloy Contact screw (branch) Copper alloy Cross Section [mm²] Dimensions [mm] 1.5-6 1.5-2.5 a 16 b 19 KS DIN 475 Thread DIN 13 grade Branch Type Number Screw number Mains Packing Unit Connector 4 M5 1 Cu 60 slotted M3 11) Ms Pieces 100 116 023 1) Contact screw (branch) 9 Parallel tap-o off clamps 109 186 198 085 Due to minimum dimensions specially suitable for cast resin joints. Suitable for solid and stranded cable conductors. Branch Connectors No evasion of mains conductor by overlapping grippers. 109 042 198 084 Also suitable for use as neutral connection clamp. Insulation caps fitting to branch terminals can be found on page 11. 109 043 109 186 Material b a Cross section [mm²] Copper alloy Screws Galvanised steel Conical spring washer Galvanised spring steel Packing Unit Connector Dimensions [mm] Type Number Branch a b KS DIN 475 Thread DIN 13 number grade DIN 267 Screw Mains Pieces Ø8 1.5-2.5 RE 18 26 13 M8 1 8.8 50 109 1862) 6 RE-70 6 RE-35 18 32 13 M8 1 8.8 50 109 042 18 32 13 M8 1 8.8 100 198 085 20 39 13 M8 1 8.8 50 109 043 20 39 13 M8 1 8.8 50 198 084 50-150 16-50 2x 16 Explanation cross sections: R=round, E=solid 1) Stud 2) Galvanised 10 Connector 1) 1) 1) Insulation covers for parallel tap-o off clamps Protection of exposed terminals against accidental touch. 109 050 Simple installation by pressing. Branch Connectors Simple disassembly of sealed cable terminals with insulation cover. 109 051 Material Black caps Soft rubber for Tap-off Clamp Type Number Type Number Page 109 042 10 109 050 109 043 10 109 051 11 T-ttype tap-o off clamps 109 001 109 003 Advantageous storage due to universal usage with large cross-sectional ranges. Stable contact behaviour, especially on aluminium conductors, due to compensation of creepage by means of spring elements. b Branch Connectors a 109 004 Pivoting pressure piece in top connector part to secure uniform partitioning of contact pressure, independent from cross sectional proportion of conductors. 109 120 Finely serrated connection channels for improved contact. Advantageous division of space with T-branches, especially in house service joints. Also suitable for use as neutral connection clamp. Insulation caps for branch terminals can be found on page 13. Material Connector Copper alloy Screws Galvanised steel Spring elements and conical spring washers Galvanised spring steel Installation tools can be found on page 27. Cross section [mm²] Dimensions [mm] outer hexagon 6-50 4-25 15 31 • 15 31 18 44 • 18 44 • 18 44 33 44 57 12 KS DIN 475 Thread DIN 13 grade b number a inner hexagon Branch 6-50 Type Number Screw Mains 50-120 Packing Unit Connector Pieces 10 M6 1 8.8 100 109 001 5 M6 1 8.8 100 109 169 13 M8 1 8.8 50 109 003 13 M8 1 A2-70 50 198 395 6 M8 1 8.8 50 109 170 • 13 M8 2 8.8 30 109 004 • 13 M8 2 8.8 15 109 006 13 M8 2 8.8 12 109 120 13 M8 1 8.8 50 109 007 6 M8 1 8.8 50 109 171 • • 70-150 50-70 42 95-150 95-150 47 62 • 120-185 6-50 18 48 • 18 48 • Insulation covers for T-ttype tap-o off clamps Protection of exposed terminals against accidental touch. 109 027 109 028 109 118 109 119 109 172 109 173 Transparent caps enable visual inspection of enclosed connector. Simple disassembly of sealed cable terminals with insulation cover. Branch Connectors Simple installation by pressing. Material Transparent caps PVC for Tap-off Clamp Type Number Type Number Page 109 001 12 109 027 109 003 12 109 028 109 004 12 109 118 109 006 12 109 119 109 169 12 109 172 109 170 12 109 173 109 171 12 109 174 109 174 13 Parallel tap-o off clamps for sectorial mains conductors Advantageous storage due to universal usage with large cross-sectional ranges. 109 060 109 061 109 081 109 063 Due to minimum dimensions specially suitable for cast resin joints. Branch Connectors Suitable for solid and stranded cable conductors. No rounding of conductor, connection channels suitable for round and sectorial conductors. Stable contact behaviour, especially on aluminium conductors, due to compensation of creepage by means of spring elements. a Finely serrated connection channels for improved contact. Also suitable for use as neutral connection clamp. Material Mutual connection of two branches. Connector Copper alloy, uncoated or tin-plated Screw Galvanised steel Spring elements and Galvanised spring steel conical spring washers Cross Section [mm²] • • • 70-150 SE 50-120 SM 16-70 RE 16-70 RM • • • • 70-185 SE 50-150 SM 70-185 SE 50-150 SM 16-70 RM 16-95 SE 95 SM • 16-120 RM 150 SE 120 SM • • • a b KS DIN 475 Thread DIN 13 Pieces 16 28 11 M7 1 8.8 100 109 060 16 28 11 M7 1 8.8 100 109 150 32 28 11 M7 2 8.8 50 109 062 32 28 11 M7 2 8.8 50 109 151 20 40 13 M8 1 8.8 50 109 061 20 40 13 M8 1 8.8 50 109 154 40 40 13 M8 2 8.8 25 109 063 40 40 13 M8 2 8.8 25 109 155 23 44 13 M8 1 8.8 20 109 080 23 44 13 M8 1 8.8 20 109 156 47 44 13 M8 2 8.8 15 109 081 47 44 13 M8 2 8.8 15 109 157 Explanation cross sections: R=round, S=sectorial, E=solid, M=stranded 14 Screw grade DIN 267 • Type Number number 6-35 RE 6-35 RM tin-plated 35-70 SE 25-50 SM uncoated Branch Packing Unit Connector Dimensions [mm] Mains b Parallel insulation-p piercing tap-o off clamps, insulated 109 214 198 388 Suitable for live installation without stripping of mains conductor. 198 414 Branch Connectors Separate installation of branch conductor from mains conductor to prevent shifting of live mains conductor during installation. No evasion of mains conductor as connection channel is closed with a slide. 109 214 h Reliable contact by piercing of main conductor insulation with insulation-piercing screws and cross cuttings. b a Strengthening of material and increased stability of up to 50% in contact area. Advantageous storage due to universal usage with large cross-sectional ranges. Material Contact screw (mains) Electrolytic copper, tin-plated Contact screw (branch) Galvanised steel Screw head (109 214, 198 408, 198 414) Plastic glassfibre-reinforced Insulated housing Plastic glassfibre-reinforced Connector Copper alloy, tin-plated Cross Section [mm²] 16 RE-150 RM 2.5-70 SE 2.5-50 RM 35RE-95 RM h 25 45 45 25 45 45 25 45 50 25 45 50 torque [Nm] 2.5-50 RM b number 16 RE-150 SE a 13 M 10 x 1 1 14 • 5 M 10 11) --- • 5 M 10 x 1 1 15-20 • 5 M 10 1 13 M 10 x 1 1 14 5 M 10 11) --- 13 M 10 x 1 1 14 5 M 10 1 inner hexagon Branch Type Number Contact Screw outer hexagon Mains 16 RE-150 RM Packing Unit Connector Dimensions [mm] 16 RE-150 SE Simple installation with fullyinsulated T-box wrench. (see pages 24 and 27). • • KS DIN 475 Thread DIN 13 • • • 1) 1) --- --- Pieces 10 109 214 10 198 388 10 198 408 10 198 4142) Explanation cross sections: R=round, S=sectorial, E=solid, M=stranded 1) Contact screw (branch) 2) This single connector is to be used only on neutral conductors or ground conductors 15 Parallel insulation-p piercing tap-o off clamps Suitable for live installation without stripping of mains conductor. Branch Connectors Separate installation of branch conductor from mains conductor to prevent shifting of live mains conductor during installation. No evasion of mains conductor as connection channel is closed with a slide. Reliable contact by piercing of main conductor insulation with insulation-piercing screws and cross cuttings. 109 094 Strengthening of material and increased stability of up to 50% in contact area. 109 097 Advantageous storage due to universal usage with large cross-sectional ranges. Simple installation with fullyinsulated T-box wrench (see page 24). 109 098 109 127 109 127 Material a 16 b Connector Copper alloy, uncoated or tin-plated Insulation piercing screw Copper alloy, uncoated or tin-plated Contact screw (branch) Galvanised steel Parallel insulation-p piercing tap-o off clamps Cross Section [mm²] 6-150 25-70 RM 50-70 SE 35-50 SM 16-35 RM / 50 RE • • • • 25-70 RM 50-70 SE 35-50 SM 16-50 RM / 70 RE 70-150 RM 70-150 SE 70-120 SM 2,5-16 RM / 25 RE 70-150 RM 70-150 SE 70-120 SM 6-150 70-150 RM 70-150 SE 70-120 SM 16-35 RM / 50 RE • • 70-150 RM 70-150 SE 70-120 SM 16-50 RM / 70 RE 70-150 RM 70-150 SE 70-120 SM 50-70 RM / 95 RE 95-240 16-95 RM 120 RE b 16 32 27 KS DIN 475 Thread DIN 13 5 M 10 x 1 1 15 5 M 10 1 5 M 10 x 1 1 5 M 10 2 5 M 10 x 1 1 15 5 M 10 11) - 5 M 10 x 1 1 15 5 M 10 1 5 M 10 x 1 1 15 5 M 10 21) - 5 M 10 x 1 1 15 5 M 10 11) - 5 M 12 x 1 1 20 5 M 10 1 5 M 12 x 1 2 20 5 M 10 21) - 5 M 12 x 1 1 20 5 M 10 11) - 5 M 12 x 1 1 20 5 M 10 1 5 M 12 x 1 1 20 5 M 10 21) - 5 M12 x 1 1 20 5 M 10 11) - 5 M 12 x 1 2 20 5 M 10 2 5 M 12 x 1 2 20 5 M 10 21) - 43 16 32 16 32 27 32 16 32 18 43 • 32 52 • 18 43 • 18 43 • 27 43 • 18 43 • 32 43 • 30 58 1) 15 1) 1) 1) 1) 1) - - - - - Pieces 30 198 025 20 109 158 30 109 094 30 198 119 20 109 095 30 198 224 30 198 026 20 109 159 30 198 208 30 109 096 20 109 097 30 198 225 10 109 098 10 109 127 Branch Connectors 25-70 RM 50-70 SE 35-50 SM • a torque [Nm] 2.5-16 RM / 25 RE Type Number Contact Screw number 25-70 RM 50-70 SE 35-50 SM tin-plated Branch uncoated Dimensions [mm] Mains Packing Unit Connector Explanation cross sections: R=round, S=sectorial, E=solid, M=stranded 1) Contact screw (branch) 17 Connection clamps for earth and neutral conductors Separate connection channels for mains and branch conductor. Secure connection of concentric ceander sheath with neutral conductor of branch cable and joint. Advantageous storage due to universal usage with large cross-sectional ranges. Contact on all untwisted ceander wires through connection channels with grippers and high shoulders. 109 179 Connection Clamps Type 109 179 especially suitable for smallest cast iron joints. 109 077 20 b a Material 109 090 Connector Copper alloy, uncoated or tin-plated Screws Galvanised steel Conical spring washers Galvanised spring steel Cross Section [mm²] • • • • • • 18 Screw KS DIN 276 Thread DIN 13 grade DIN 267 16-95 Type Number suitable for earthing screw 16-95 tin-plated Branch uncoated Dimension [mm] Mains Packing Unit Connector Pieces - 13 M8 8.8 50 109 179 42 - 13 M8 8.8 50 109 185 22 73 M 10 13 M8 8.8 40 109 077 22 73 M 10 13 M8 8.8 40 109 090 22 73 M 12 13 M8 8.8 40 109 087 22 73 M 12 13 M8 8.8 40 109 091 a b 20 42 20 Aluminium flat direct terminals for connection of cable conductor ends to circuit bars or flat bars → Technical information on page 7 206 024 Finely serrated connection channel and connection area for improved contact. Material Connectors made of aluminium alloy h 206 032 Connector Aluminium alloy, hardened and tempered Screws Galvanised steel Conical spring washers Galvanised spring steel Connectors made of copper alloy a Cross Section [mm²] b Connector Copper alloy, tin-plated Screws Galvanised steel Conical spring washers Galvanised spring steel Packing Unit Connector h KS DIN 475 Thread DIN 13 Terminals b grade DIN 267 a Screw number Dimensions [mm] Type Number Pieces 8.8 30 206 024 50 206 032 30 206 033 50 206 034 30 206 014 100 106 047 Direct terminals made of aluminium alloy with tin-plated lower part 50 RE 35-150 SM 50-185 SE 28 38 32 28 38 32 19 M 12 x 55 2) 1 for switchgear: stud M 12 x 55 1) Direct terminals made of aluminium alloy with tin-plated upper and lower part 50 RE 35-150 SM 50-185 SE 50-120 SM 150 SE 28 38 32 28 38 32 28 33 32 19 M 12 x 55 2) 1 for switchgear: stud M 12 x 55 19 M 12 x 50 2) 8.8 1) 1 8.8 Direct terminals made of copper alloy with tin-plated upper and lower part 10-35 RM 35 SM 70 SE 20 25 25 20 25 25 13 M 8 x 35 50 RE 25-150 SM 50-185 SE 26 38 30 19 M 12 x 50 26 38 30 19 M 12 x 55 26 38 30 Explanation cross sections: R=round, S=sectorial, E=solid, M=stranded 1) Check dimensions of stud before order 2) Recommended torque: M 8 max. 22 Nm, M 12 = 40 Nm for switchgear: stud M 8 x 35 1) 1 8.8 50 106 052 2) 1 8.8 30 106 050 2) 1 8.8 30 106 057 40 106 054 2) for switchgear: stud M 12 x 50 1) 19 V-ttype direct terminals for connection of cable conductor ends with V-s shaped plates → Technical information on page 7 206 028 Finely serrated connection channel and connection area for improved contact. Material Pressure piece Copper alloy, tin-plated Screws Galvanised steel Conical spring washers Galvanised spring steel Frame Aluminium alloy 206 039 Type Number Accessories V-shaped plates for 206 028 and 206 039 198 358 V-shaped plates for 206 019 198 359 Insulation cap for 206 028 206 029 Terminals 206 028 a 206 029 198 358 b Cross Section [mm²] Packing Unit Connector Dimensions [mm] Type Number a b KS DIN 475 Thread DIN 13 number torque [Nm] Contact Screw Pieces 18 28 5 M 10 1 25 50 206 019 23 36 6 M 12 1 25 40 206 028 23 36 6 M 12 1 25 40 206 039 23 36 6 M 12 1 25 40 298 240 Suitable for V-shaped plates 20x3 16-95 SE 95 SM Suitable for V-shaped plates 25x3, 25x4 50-240 SE 35-185 SM 70-240 SM Explanation cross sections: S=sectorial, E=solid, M=stranded 1) Shear-head screw 20 1) Transformer clamps and connection terminals for transformer bushings DT 630 and DT 1000 → Technical information on page 8 105 027 105 029 Advantageous storage due to universal usage with large cross-sectional ranges. Best contact transition conditions and good protection against loosening by additional clamping of threaded connection element. Finely serrated connection channel and connection area for improved contact. 105 037 Material Copper alloy, tin-plated Screws Galvanised steel Conical spring washers Galvanised spring steel Nuts Galvanised steel Packing Unit Connector Type Number Terminals Cables Connector 120-240 RM 120-240 SM 150-300 SE 120-240 SM 150-300 SE Number Type Transformer stud KS DIN 475 Thread DIN 13 grade DIN 267 Cross Section [mm²] number Screw Pieces 1-2 90° offset M 20 17 M 10 2 8.8 4 105 027 M 30 x 2 17 M 10 2 8.8 4 105 028 1-3 M 20 17 M 10 2 8.8 3 105 029 1-3 M 30 x 2 17 M 10 2 8.8 3 105 030 M 30 x 2 17 M 10 2 8.8 4 105 037 M 30 x 2 17 M 10 2 8.8 4 105 039 1-2 1-2 1-3 straight Explanation cross section: R=round, S=sectorial, E=solid, M=stranded 21 Contact plates, pressure plates and separating wedges 504 083 Contact plates for removal of oxide and foreign layers, elastically smooth out irregularities and create optimum contact connections. 504 065 Pressure plates stabilise contact behaviour through compensation of creepage deformation, especially with aluminium, by means of spring elements. Dimensions [mm] for Transformer Stud Packing Contact plate 40 x 30 M 12 100 504 083 Material Pressure plate 30 x 30 M 12 200 504 064 Pressure plate 40 x 40 M 12 100 504 065 Contact plate Copper alloy, hardened and tin-plated Pressure plate 40 x 40 M 16 100 504 066 Contact and Pressure Plates Pieces Type Number Pressure plate Spring steel, hardened and galvanised Separating wedges Accessories 109 101 Separating wedges with high leakage current strength for uniform spacing of cable conductors. 109 102 Cables 22 Dimensions [mm] Type Number Cross Section [mm²] Number 25-150 3 48 x 14 109 101 25-150 4 48 x 14 109 102 Installation Tool Box for Cables, Insulated Tools Our installation tool box is compiled for installation works on low voltage cable networks, such as installation of service joints or connection joints, or connections to cable distribution boxes. All tools are of high quality and VDE-tested, with impact resistant plastic insulation. Tools are assembled in a rigid plastic case and have an optimum protection through tailored foamed inserts. Installation Tool Box for Cables equipped Scope of delivery, see below Type number 620 162 SCOPE OF DELIVERY: T-Box Wrench Hexagon socket screw SW 4 SW 5 SW 6 Type number Angular Wrench Hexagon socket screw SW 5 SW 6 Type number Screwdriver 75 x 2.5 100 x 3.5 125 x 5.5 150 x 6.5 Type number 620 101 620 102 620 103 620 104 Ratchet Wrench ratchet wrench (with insert KS 5) insert KS 5 insert KS 6 Type number 620 090 620 155 620 156 620 157 Installation Tools 620 159 620 160 620 137 05 620 137 06 23 Installation Tool Box for Cables, Insulated Tools Torque Wrench torque wrench 20 Nm (inserts excluded) insert KS 5 insert KS 6 Type number 620 147 620 148 620 149 Installation Tools Function: ARCUS torque wrench is released after clockwise rotation. When torque is reached, the release is audible and perceptable. Testing: ARCUS torque wrenches are supplied with test certificate and each with its own serial number. Precision: ARCUS torque wrenches are manufactured with release precision of ±1 Nm. 24 Universal Pliers length: 200 mm Type number 620 096 Flat Pliers length: 160 mm Type number 620 097 Round Pliers length: 160 mm Type number 620 099 Insulation Stripping Tongs length: 160 mm Type number 620 100 Wire Cutting Pliers length: 160 mm Type number 620 098 Installation Tool Box for Cables, Insulated Tools Cable Knife fixed blade Type number 620 105 Spreading Wedge length: 120 mm Type number 109 177 Plastic Folding Rule length unfolded: 2000 mm with metric markings Type number 620 095 Installation Tools Case Type number inside dimensions: 410 x 360 x 90 mm 615 051 with foamed inlay 25 Insulated Tools Spreading Wedge, long version length: 198 mm Type number 198 184 T-Handle Socket Wrench KS 10, 200 mm long KS 11, 200 mm long KS 12, 200 mm long KS 13, 200 mm long KS 14, 200 mm long KS 17, 200 mm long KS 19, 300 mm long KS 20, 300 mm long KS 22, 300 mm long KS 24, 300 mm long KS 27, 300 mm long KS 28, 300 mm long KS 30, 300 mm long KS 32, 300 mm long Type number 620 031 620 032 620 033 620 034 620 035 620 036 620 037 620 038 620 039 620 040 620 041 620 042 620 043 620 044 Case made of synthetic material with foamed inlay to take up one torque wrench and two inserts. Type number 615 040 Installation Tools Note: Products shown on this page are not part of the installation tool box (type no. 620 162) on page 23. 26 Catalogues from Product Range “Cable Connection Technique“ Screw Connectors and Screw Cable Lugs Ring Connectors Single Connectors Phone General +49 (0) 89 / 4 36 04 - 0 Fax General +49 (0) 89 / 4 31 68 88 Internet www.ARCUS-Schiffmann.com [email protected] Seat of the Company Truderinger Str. 199 D-81673 Munich Edition: 08.2015 Subject to change without notice Copyright © ARCUS Schiffmann Layout: Marion Renz Fax Sales Department +49 (0) 89 / 4 36 04 - 73
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement