TroposAir | 88800 | Instructions / Assembly | TroposAir 88800 Instructions / Assembly

Owner’s Manual
ProSeries Builder Indoor
5BD52
This instruction contains 5 pages:
Page 1: Foreword
Page 2: Unpack and inspect parts contained
Page 3: Notes before installation
Page 3~4: Hanging system installation and Wire connection
Page 5: C anopy / Blade / Pull Chain Knob installation
Net weight
UL
R
5.7 KGS.
12.5 LBS.
Toll Free: 1-855-676-7247
WARNING : Read and follow these instructions carefully and be mindful of all warnings shown throughout.
READ AND SAVE THESE INSTRUCTIONS
WARNING : TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY
TO PERSONS, PLEASE OBSERVE THE FOLLOWING :
1]. To ensure the success of the installation, be sure to read the instructions and review the diagrams
thoroughly before beginning.
2]. To avoid possible electric shock, be sure electricity is turned off at the main power box before wiring.
All electrical connections must be made in accordance with local codes, ordinances and/or the
National Electric Code. If you are unfamiliar with the methods of installing electrical wiring and
products, secure the services of a qualified and licensed electrician as well as someone who can
check the strength of the supportive ceiling members and make the proper installations and
connections.
3]. Make sure that your installation site will not allow rotating fan blades to come in contact with any
object. Blades should be at least 7 feet from floor when fan is in operation.
4]. If possible, mount ceiling fan on a ceiling joist - the joist must be able to support the motion and weight
of the moving fan. If the fan will be mounted on a ceiling outlet box, a 4" x 2-1/8" deep METAL octagon
box is required ; one UL listed as " suitable for fan support ". The box and its supporting members must
not be able to twist or work loose. DO NOT USE PLASTIC BOXES. Installation on a concrete ceiling should
be performed by qualified personnel.
5]. Blades should be attached after motor housing is hung and in place. Fan motor housing should be
kept in carton until ready to be installed to protect its finish. If you are installing more than one ceiling
fan, make sure that you do not mix fan blade sets.
6]. After making electrical connections, spliced conductors should be turned upward and pushed
carefully up into outlet box. The wires should be spread apart with the grounded conductor and the
equipment - grounding conductor on one side of the outlet box and the " HOT " wires on the other side.
7]. Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL/ETL listed
and should be installed per the light kit's installation instructions.
8]. After fan is completely installed, check to make sure that all connections are secure to prevent fan
from falling and/or causing damage or injury.
9]. The fan can be made to work immediately after installation. The bearings are adequately charged with grease,
so that under normal conditions, further lubrication should not be necessary.
10]. The fan must be turned off and stopped before reversing fan direction.
11]. This fan is suitable for three mounting ways: Downrod (standard)/ Flush (Hugger) / Slope ceiling.
12]. This fan is reversible.
13]. This fan is light kit adaptable.
14]. This fan is remote adaptable.
15] . This fan is suitable for indoor use.
P1
Unpack and inspect fan carefully to be certain
all contents are included.
Hardware Bag
For Mounting Bracket:
Mounting
Bracket
Flat Washer x2
Spring Washer x2
Machine Screw x2
Wood Screw x2
For Wire Connection:
Wire Nut x 3
Downrod
Assembly
For Flush Mount On l y:
Canopy Set Screw x 3
For Blade Installation:
Blade Screw x 16 (one spare screw included)
Canopy
Paper Washer x 16 (one spare washer included)
Canopy
Decorating Cap
Motor Screw x 11
(one spare screw included)
Wires
For Fan :
Pull Chain Knob x1
Fan Assembly
For Blade Balance :
Balancing slide x 1
Weight block (3G x 3)
Blade x5
Blade Holder x5
P2
3G
M
3G
M
3G
M
WARNING: blades should be at least 7 feet from floor
Note 1:
Note 2:
Turn off power at breaker
box to avoid possible
electrical shock.
Use metal outlet box suitable
for fan support.
Outlet box must support 35 lbs min.
OFF OFF OFF
1. HANGING SYSTEM INSTALLATION
1A.Installing mounting bracket to ceiling outlet box
Install mounting bracket to outlet box in ceiling by using screws
included with the outlet box and washers from the hardware bag.
Outlet Box
Mounting
Bracket
1B. This fan has two installation methods available:
1 Downrod mount (Standard) : Please follow up Step 1C and 1D.
2 Flush mount (Hugger) : Please directly go to Step 1E and 1F.
2 Flush mount
1 Downrod mount
(See Step 1C and 1D)
(See Step 1E and 1F)
1C. Installing Downrod and Yoke (For Downrod mount)
1 Remove cross pin and cotter pin from downrod.
2 Insert downrod through canopy, and feed motor lead wires through downrod.
3 Loosen 2 downrod jam screws at yoke. Insert downrod assembly into yoke.
4 Insert the cross pin through yoke & downrod and secure with cotter pin.
5 Tighten both downrod jam screws to further secure downrod.
Downrod
2 Wires
1 Cotter Pin
3
Canopy
Downrod Jam
Screw(2)
( Loosen ing)
Downrod
Assembly
1 Cross Pin
4 Cotter Pin
5
Yoke
Downrod Jam
Screw(2)
(Tightening)
4 Cross Pin
Yoke
P3
1D. Hanging the fan (For Downrod mount)
Rotate fan so that the groove on the ball engages
the ridge in the mounting bracket.
Lift fan assembly onto mounting bracket.
Mounting
Bracket
Mounting
Bracket
Ridge
Ball Groove
1E. Canopy Assembly (For Flush mount)
1F. Hanging the fan (For Flush mount)
1 Remove canopy decorating cap from bottom of canopy.
2 Fasten 3 canopy set screws provided from hardware bag
Lift the fan assembly and hang onto the tab on
mounting bracket.
onto fan assembly firmly.
Note: This will permit you to make the wire connections
without having to hold the fan up as well.
2 Canopy
set screw (3)
Mounting
Bracket
Canopy
Tab
1 Canopy
decorating cap
Fan assembly
Fan assembly
2. WIRE CONNECTION
Making electrical wire connection
Follow diagram below and make sure that all exposed wires are secured inside wire nuts or terminal block.
Note : Wires from house may vary in color and may not include ground wire ( green ).
*White wire from house to white wire from fan
*Black wire from house to black wire and blue wire from fan
*Ground wire from house to green wire from downrod and from mounting bracket
*Secure with twist - lock wire nuts. (Included)
* After wiring is completed, gently push wires into junction box with wire nuts pointing upward.
From House
Wire Form House
Outlet Box
From Fan
White
White
Black
(AC-N)
(MOTOR-N)
(AC-L)
(MOTOR-L)
Black
(For Light Kit)
Green
( for ground wire )
Secure with twist - lock wire nuts.
P4
( from downrod )
( from mounting bracket )
Blue
Green
Green
3. CANOPY INSTALLATION
Note: Four screws are pre-screwed on mounting bracket for canopy installation.
1 Remove left-hand side screw on mounting bracket first and loosen the other one.
( Note: Please do the same for the other two screws on the across side of mounting bracket.)
2 Rotate the canopy slightly until both two loosening screws are in the holes of L type slots.
3 Tighten 4 screws firmly.
2 L Type Slots
3
Screw (4)
( Tightening )
1
Left-hand
side screw
(Removing)
Screw
(Loosening)
4. BLADE INSTALLATION
1 Attach blade to blade holder with 3 blade screws and 3 paper washers provided from hardware bag.
Make sure all screws are firmly tightened.
2 Remove 3 motor stoppers by removing screws .
3 Secure Blade Assembly to the motor with 2 motor screws provided from hardware bag.
NOTE: To prevent wobble, do not bend blade or blade holder.
2
Motor
Stopper (3)
1 Blade Screw (3)
Paper Washer (3)
Blade
3
Blade Holder
Blade Assembly
Motor screw (2)
5. PULL CHAIN KNOB INSTALLATION
Connect Pull Chain Knob provided from hardware bag to the pull chain from switch housing.
Fan Assembly
Switch Housing
Pull Chain Knob
6.Turn on the power at breaker box - your fan is ready for operation.
P5