UPS DELPHYS MP elite - Full Link Technology Co Ltd
Three-phase
UPS
DELPHYS MP elite
from 60 to 200 kVA
your protection up to 1200 kVA
High quality power supply
Easily integrated equipment
Cost effective equipment
•D
elivered by SVM digital modulation (Space
Vector Modulation).
• Adapted to supply new IT loads with a
leading power factor up to 0.9 without
derating.
• With sinusoidal voltage for non-linear loads
(Crest Factor 3:1).
•A
n IGBT rectifier which virtually eliminates
harmonic distortion without filters, thus
removing any stress on your power supply
network.
• Reduced current consumption due to an
input power factor of 0.99 without derating
constant in every situation.
• The ideal solution for grouping with
generator sets without using an excessively
large generator.
•A
compact unit for a smaller footprint.
• An IGBT rectifier, which reduces the size
of the infrastructure (transformer, generator
set and distribution)
• The ENERGY SAVER function, staying in
on-line mode and keeping the redundancy
required.
High availability
•A
fault tolerant architecture with redundancy
of basic functions, such as the ventilation
system.
• A variety of architectures for parallel
operations, to deal with redundancy,
management and changes in power
output.
Battery availability at all times
•A
n innovative load algorithm which adapts
to the environmental conditions and the
condition of the battery to increase its life.
• A highly-developed monitoring system,
capable of locating and correcting any
problems interacting with the charging
device.
User-friendly operation
•A
control panel with graphic display for
more ergonomic operation.
• An array of “com-slot” plug-in communication
interfaces, for upgrading your operating
requirements.
Simplified maintenance
• An
advanced diagnostic system.
• A remote access device connected to the
remote maintenance centre.
• Easy access to subassemblies and
components, facilitating tests and reducing
maintenance time (MTTR).
Remote monitoring
defys 121 B 1 cat
• Easy
remote monitoring via web browser
or via customer’s supervision systems
(web, intranet, extranet…).
• Very open connectivity (Modbus / Jbus,
Jbus tunnelling, LAN…).
56
Your protection
for
> Data centre
> Industry
> Telecommunications
> Processes
DELPHYS MP elite
Three-phase
UPS
from 60 to 200 kVA
High quality power adapted to new IT loads
LEADING
cos ϕ 0,9
LAGGING
kW
100% kW cos ϕ 1
cos ϕ 0,8
cos ϕ 0,9
cos ϕ 0,8
cos ϕ 0,7
1
cos ϕ 0,6
DEFYS 091 B GB
0,75
0,50
k
0%
Without de-rating
V
vaA
•a
ctive power without de-rating, for loads
with a lagging power factor and up to 0.9
leading,
• a high short-circuit capacity, up to 4 In,
which facilitates the selection of protective
devices for selectivity in the downstream
distribution,
• an Iisolation transformer is installed on
the inverter output to ensure complete
galvanic isolation between DC circuit and
load output.
10
The SVM digital modulation (Space Vector
Modulation) fitted to the transformer integrated
downstream of the inverter allows supply to
your installations with:
• precise voltage even when the load between
phases is completely unbalanced,
• stable output voltage during significant and
quick variations in loads (± 2 % in less than
5 ms),
• sinusoidal THDV output voltage < 2 %
with linear loads and < 3 % with non-linear
loads,
0,25
-1
-0,8
-0,6
-0,4
-0,2
0
0,2
0,4
0,6
0,8
1
kVAr
DELPHYS MP elite easy to integrate into your electrical network
A consistent rectifier
An economical IGBT rectifier
It eliminates any disturbance on the upstream
network (source and distribution).
• The cutting rectifier guarantees the supply
of current with an exceptionally low rate of
harmonic distortion: THDI < 2.5 %.
•T
he performance of the IGBT rectifier is
independent of frequency variations that
could be produced by the generating set.
• The power factor and THDI at the rectifier
input are constant whatever the battery
charge status (continuous voltage level)
and the load rate of the UPS.
• The
power factor upstream of the rectifier:
0.99, reducing the kVA used by 30 % when
compared with conventional technology.
The reduction in input current results in
a saving in terms of the scale of sources,
cables and protective devices.
• Rectifier capabilities:
- low upstream THDI,
- gradual, timed restarting,
- possibility of suspending battery recharge
when operating with a generator set, allow
the impact caused when the generator set is
engaged and the energy used to be reduced,
along with the footprint.
DEFYS 127 A 1 cat
A “clean” IGBT rectifier
EBS Technology (Expert Battery System)
This exclusive feature prolongs battery life.
• It carries out the charge according to an
algorithm which adapts to the environment
and the condition of the battery.
• It reduces corrosion and drying out of the
separators often caused by permanent
floating loads.
• It reduces the residual ripple of the current,
one of the causes of premature battery wear.
BHC Technology (Battery Health Check)
Guaranteed battery availability:
• the battery and DC circuit are regularly
tested automatically and the operator is
notified of their condition,
• optional BHC function tests analyse the
following parameters: current by branch,
voltage by segment or block. In case of
drift, the interactive system automatically
takes corrective charging measures. If the
drift continues, an alarm with the location
of the failure (branch, segment or block)
allows the necessary preventative repairs
to be made.
DEFYS 145 A GB
Guaranteed available back-up time
57
Three-phase
UPS
DELPHYS MP elite
from 60 to 200 kVA
Parallel systems
• DELPHYS MP elite modular,
development without constraint.
• DELPHYS MP elite redundant bypass,
for greater availability.
• DELPHYS MP elite a twin channel
architecture with Static Transfer Systems.
ACS
DELPHYS
MP elite
ACS
defys 065 A
In order to meet the most demanding
availability requirements, and the need for
the installation to be flexible and upgradable,
up to 6 DELPHYS MP elite can run in
parallel.
DELPHYS
MP elite
STS 1
defys 093 a
• DELPHYS MP elite double bypass,
to simplify operation.
Load 1
STS 2
defys 059 B
DEFYS128 C Gb
Load 2
• DELPHYS MP elite centralised bypass,
progressive development.
defys 094 a
• DELPHYS MP elite multi bypass,
to separate application types.
STS 3
Load 3
Battery
The key element in a UPS
The Socomec batteries are selected for their
quality manufacture, robustness and ability to
restore power when needed.
Standard equipment
defys 026a
• Slots for 7 communication cards.
• Protection backfeed: detection circuit.
• Standard interface:
- 3 inputs (emergency stop, generating set,
battery protection),
- 4 outputs (general alarm, back-up, bypass,
preventative maintenance needs).
Graphic display
Design adapted to the user: control panel with LEDs and LCD display.
Accessories
HC battery unit monitoring.
B
EBS (Expert Battery System).
Graphic touch screen.
ACS function for synchronisation with an
external source.
• Reinforced IP protection degree.
• Ventilation filters.
• Ventilation control.
DEFYS 111 A GB
•
•
•
•
Communication options
Graphic touch screen (GTS)
The operator has access to the control functions with only a few intuitive touches of the screen.
Operating mode
icons
Direct access zones
to sub-unit menus
Help menu for
correct operation
UPS load rate
(bar graph)
Access to installation mimic
panel
Status bar
58
DEFYS 102 A
Quick access to each
installation module
Preventative maintenance
request
•R
emote control panel.
• ADC (Advanced Dry Contacts) data input
and output by dry contacts.
• RS232, RS422, RS485 serial port
JBUS / MODBUS or PROFIBUS.
• MODBUS TCP interface (JBUS / MODBUS
tunneling).
• NET VISION interface for the LAN Ethernet
network.
Remote maintenance
•T
.SERVICE for continuous 24/7 monitoring
the SOCOMEC UPS maintenance service.
Three-phase
UPS
DELPHYS MP elite
from 60 to 200 kVA
UPS and batteries
A compact and integrated system.
Battery for back-up time
UPS power
kVA / kW
60 / 48
80 / 64
100 / 80
120 / 96
160 / 128
200 / 160
10 minutes
W
mm
800
800
800
800
1600
1600
Bypass cabinet
The coupling
functions.
15 minutes
Weight
kg
810
1200
1230
1310
2390
2460
W
mm
800
800
800
1600
1600
2400
Weight
kg
1200
1270
1310
2390
2530
3590
1930
DELPHYS MP
elite
Weight
kg
700
700
820
820
980
980
DEFYS 126 B f
UPS
W
10
0
00
80
On line double conversion
and
centralised
bypass
Maintenance
Bypass
Weight
kg
300
300
300
300
370
370
370
370
420
600
(1) For other power ranges, please consult us.
Automatic
Bypass
Q5
Q4
Rectifier
Inverter
Q3
Q20
DEFYS 164 A GB
W
mm
800
800
800
800
800
800
800
800
1000
1300
Power(1)
kVA
60
80
120
200
250
300
400
500
800
1200
Battery
DEFYS 125 A GB
1930
Technical data
W
80
Rectifier input
Technology
Voltage Acceptable tolerance Frequency Power factor
Distortion rate
Output
Voltage (configurable)
Voltage tolerance
static load
dynamic load conditions from 0 to 100 %
Voltage distortion rate
Acceptable crest factor without de-rating
PF acceptable without de-rating
0
Bypass transformer
For galvanic isolation.
W
mm
600
600
600
800
1000
1200
Power(1)
kVA
60
80
120
200
300
400
Weight
kg
400
450
550
850
1250
1500
1930
DEFYS 087 A GB
0
< 1 %
± 2 % in 5 ms
THDU < 2 %
3:1
lagging to 0.9 lead.
50 - 60 Hz
Autonomous frequency tolerance
Overload
± 0.2 %
1 min: 150 %
10 min: 125 %
Efficiency
Global (2)
In ECO-MODE configuration
Environment
Noise level (ISO 3746) (2)
Compliance to standards
safety
EMC
technical data
Classification according to IEC 62040-3
80
three-phase + N 380 V - 400 V - 415 V (1)
Frequency (configurable)
(1) For other power ranges, please consult us.
W
PFC - IGBT
three-phase 380 V - 400 V - 415 V (1)
340 to 460 V
50 - 60 Hz (45 to 65 Hz)
0.99 constant
THDI: 2.5 % without filter
94 %
98 %
67 dBA
IEC62040-1-2 / IEC60950
IEC 62040-2
IEC 62040-3
Voltage Frequency Independent, on-line double conversion VFI - SS - 111
(1) Three-phase 220-230-240 V on demand. - (2) As per power range.
dcg_84063
(1) For other power ranges, please consult us.
VALID FOR FRANCE
VALID FOR ITALY
ISO 9001:2008
FM 28237
ISO14001:2004
EMS 553476
www.socomec.com
Non contractual document.
© 2010, Socomec SA. All rights reserved.
59
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement