Sea gull lighting | 94563-965 | Installation guide | Sea Gull Lighting 94563-965 Installation Guide

LR-118
Installation And Safety Instructions
Line art shown may not exactly match the fixture enclosed. However, the installation instructions do apply to this
fixture. Fill in Item Number on Carton and File This Sheet For Future Reference. ITEM#_______________
041409
IMPORTANT SAFETY INSTRUCTIONS
•
Be sure the electricity to the system you are working on is turned
off; either the fuse removed or the circuit breaker set at off.
•
•
For use with the 120V Transitions track series by Sea Gull Lighting.
Caution – To reduce the risk of burn during relamping remove from
the track before relamping.
If you are unclear as to how to proceed, contact a qualified
electrician.
Minimum distance from the front of the lamp to combustible
surfaces is 8".
Make sure all connections are tight.
Dimming halogen lamps greatly reduces lamp life.
Turn off and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact switch only when turning on.
Do not touch hot lens, guard, or enclosure.
Keep lamp away from materials that may burn.
Do not touch the lamp at any time. Use a soft cloth. Oil from skin
may damage lamp.
Do not operate the luminaire fitting with a missing or damaged
shield.
Save these instructions.
•
•
•
•
•
•
•
•
•
•
•
NOTE: This pendant can be hung either from a Transitions Series
rail (not supplied) or from the supplied canopy. Follow the
instructions for the appropriate mounting method.
ASSEMBLING PENDANT/SHORTENING PENDANT
1. Determine length of pendant and shorten cable from the splice
compartment (C). Be sure to add 5" for electrical connections
when installing as a mono-point.
2. Unthread top of splice compartment (C). Set top of splice
compartment (C) and strain relief collar at new location. NOTE
Strain relief collar is threaded and should be threaded up and
down cable. Be sure 1/4" of cable jacket is protruding out of
strain relief collar. Secure in place by tightening the two set
screws.
3. Place glass support (F) at desired height on stem (O) and secure
by tightening set screw with supplied allen wrench. Place shade
(A) on top of glass support (F) so it hangs evenly. Place hood (G)
on top of shade (A).
4. Make connections between socket leads and pendant cable
using wire nuts inside the splice compartment (C) – Black to
Black/White to White/Ground to Ground. Make sure no wires are
left exposed and carefully tuck wire nuts into bottom half of splice
compartment (C).
5. Close splice compartment (C) by threading the two halves
together.
*RAIL
STRAIN RELIEF
SET SCREWS (D)
RAIL
ADAPTER (E)
COLLAR (L)
*OUTLET
*BOX
MONOPOINT
CANOPY
(K)
SPLICE
COMPARTMENT
(C)
STEM (O)
GLASS
SUPPORT (F)
HOOD (G)
SOCKET (Q)
SHADE (A)
RETAINING
RING (H)
FIGURE 1
LAMP
ENCLOSURE
(B)
*NOT INCLUDED
GROUNDING AND MOUNTING BAR
LOCK UP FOR OPTIONAL
MONO-POINT CANOPY
*OUTLET BOX
WIRE
CONNECTORS
*GROUND WIRE
*OUTLET BOX
SCREWS
NIPPLE (V)
STRAIN RELIEF (O)
HEX NUT AND
LOCK WASHER (B)
MOUNTING
BAR (J)
CANOPY (K)
COLLAR (L)
FIGURE 2
*NOT INCLUDED
FOR MONO-POINT INSTALLATION – REFER TO FIGURE 2
LR-118
1. Remove rail adapter (E) by cutting wire below rail adapter (E).
Carefully strip outer jacket so wires are exposed to make wire
connections.
2. Slide collar (L), canopy (K), and hex nut and lock washer (B),
mounting bar (J), and nipple (V) over wire to top of splice
compartment (C).
3. Install strain relief (O). Tighten strain relief set screw with a flat
head screw driver.
4. Secure mounting bar (J) to outlet box using outlet box screws (not
supplied).
5. Make electrical connections with UL listed connectors such as
wire nuts.
a. House Black to Fixture Black
b. House White to Fixture White
Take house ground wire and fixture ground wire and wrap around
the green grounding screw located on the mounting bar (J).
Secure by tightening the green grounding screw. Make sure no
wires are left exposed and tuck wires into outlet box.
6. Raise canopy (K) against ceiling and thread collar (L) to the nipple
(V).
ATTACH PENDANT TO RAIL – REFER TO FIGURE 3
1. Unthread cap (R) from rail adapter (E).
2. Making sure contacts (P) will align with conductors (Q) on rail, set
the bottom of rail adapter (E) to the bottom of the rail and “roll”
rail adapter (E) up onto the rail.
3. Close the hinged door of rail adapter (E) over the rail and secure
fixture to rail by threading cap (R) back onto rail adapter (E).
4. Use supplied allen wrench to tighten strain relief set screws (D).
FIXTURE INSTALLATION
CORRECT
CONTACTS (P)
INCORRECT
CONTACTS (P)
CAP (R)
RAIL
ADAPTER
(E)
RAIL
ADAPTER
(E)
CAP (R)
FIGURE 3
CONDUCTOR (Q)
CONDUCTOR (Q)