Sea gull lighting | 5101-07 | Installation guide | Sea Gull Lighting 5101-07 Installation Guide

HC-359
Installation And Safety Instructions
Line art shown may not exactly match the fixture enclosed. However, the installation instructions do apply to
this fixture. Fill in Item Number on Carton and File This Sheet For Future Reference. ITEM#_______________
IMPORTANT SAFETY INSTRUCTIONS
•
•
Be sure the electricity to the system you are working on is turned off;
either the fuse removed or the circuit breaker set at off.
Use of other manufacturers components will void warranty, listing and
create a potential safety hazard.
If you are unclear as to how to proceed, contact a qualified electrician.
You don’t need special tools to install this fixture.
Be sure to follow the steps in the order given.
Under no circumstances should a fixture be hung on house
electrical wires, nor should a swag type fixture be installed on a ceiling
which contains a radiant type heating system.
Read instructions carefully.
Save these instructions.
•
•
•
•
•
•
SMALL CANOPY ASSEMBLY
FIXTURE LOOP (K)
SMALL NIPPLE (I)
PLATE (X)
HICKEY (J)
LOCK WASHER (W)
LOCK WASHER (W)
SMALL CANOPY (V)
SMALL NIPPLE (I)
SWIVEL (U)
CENTER PIPE TOP ROD (ZZ)
CLEANING
To clean, wipe fixture with a soft cloth. Clean glass with a mild soap. Do not
use abrasive materials such as scouring pads or powders, steel wool or
abrasive paper.
GROUND
WIRE (E)
*NOT INCLUDED
FIGURE 1
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order
replacement parts. Parts for this fixture can be ordered from place of
purchase. Be sure to use exact wording from illustration when ordering parts.
FOR CHAIN HUNG
BEFORE YOU BEGIN
Carefully remove the fixture from the carton and check that all parts are
included, as shown in Figure 1, 2, & 3. Be careful not to misplace any of the
screws or parts which are needed to install this fixture.
GREEN
GROUNDING
SCREW (D)
FOR CHAIN HUNG (FIG. 1)
STEP 1:
(MAY ALREADY BE FACTORY INSTALLED) Feed fixture wires from center
pipe bottom rod (T), center coupling (XX), and center pipe top rod (ZZ)
through: swivel (U), small nipple (I), small canopy (V), lock washer (W), ground
wire (E), lock washer (W), hickey (J) and plate (X), in that order (if applicable).
Secure in place with fixture loop (K).
(MAY ALREADY BE FACTORY INSTALLED) Insert small loop (L) through
small canopy (V). On small loop (L), place lock washer (W) and secure in place
with nut (MM).
FOR FLUSH MOUNT
* OUTLET BOX
* OUTLET BOX
* GROUND WIRE
* WIRE
CONNECTOR
MOUNTING BAR (A)
* OUTLET BOX SCREWS
NUT (B)
NIPPLE (C)
GROUND WIRE (E)
SCREW COLLAR (H)
CANOPY (G)
SCREW COLLAR
RING (F)
CHAIN (N)
STEP 2:
CENTER
COUPLING (XX)
SHORT
CHAIN
LOOP (RR)
LARGE
LOOP (YY)
* WIRE CONNECTORS
NUT (MM)
040209
MOUNTING BAR (A)
FIXTURE LOOP (K)
SMALL CANOPY (V)
SMALL LOOP (L)
LONG CHAIN
LOOP (QQ)
CHAIN
ASSEMBLY (P)
CENTER PIPE
TOP ROD (ZZ)
CENTER PIPE
BOTTOM ROD (T)
FIXTURE HOOKS (Z)
SWIVEL (U)
FIGURE 3
LOCK WASHER (W)
CANOPY (O)
CAP NUTS (S)
SMALL NIPPLE (I)
SMALL LOOP (L)
CENTER PIPE BOTTOM ROD (T)
*NOT INCLUDED
FIXTURE RING (Q)
NIPPLE (M)
DIFFUSER (R)
DECORATIVE CUP (Y)
FINIAL (AA)
FIGURE 2
*NOT INCLUDED
FOR FLUSH MOUNT (IF APPLICABLE) (FIG. 3)
HC-359
NOTE: If fixture is pre-assembled for chain hanging, and you wish to
flush mount it, first take apart the chain hung assembly, by removing
parts as noted in step 1 and step 2 of assembly for chain hung.
STEP 1:
(MAY ALREADY BE FACTORY INSTALLED) Feed fixture wires from center
pipe bottom rod (T) through: swivel (U), small nipple (I), canopy (O) and lock
washer (w), in that order (if applicable). Secure in place with nut (MM).
STEP 2:
Using two pair of pliers open and remove one short chain loop (RR) and one
long chain loop (QQ) from chain assembly (P).
STEP 3:
GROUNDING AND
MOUNTING BAR LOCK UP
* OUTLET BOX
* GROUND WIRE
* WIRE CONNECTORS
MOUNTING BAR (A)
MOUNTING SCREWS (BB)
GREEN GROUNDING SCREW (D)
FIGURE 4
(MAY ALREADY BE FACTORY INSTALLED) Insert small loop (L) through
canopy (O). On small loop (L), place lock washer (W) and secure in place with
nut (MM).
* OUTLET
BOX
SCREWS
*NOT INCLUDED
FINAL ASSEMBLY
Make sure no bare wires can be seen outside wire connectors.
INSTALLATION
IMPORTANT: DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET BOX.
FOR CHAIN HUNG (FIGURE 2)
1. After wires are connected, tuck them carefully inside outlet box and then
raise the small canopy (V) against ceiling and screw the screw collar ring
(F) to the screw collar (H).
FOR CHAIN HUNG (FIGURES 1 & 2)
1. Secure mounting bar (A) to outlet box with outlet box screws (not
supplied). Thread nut (B) on nipple (C) so that 3 threads are exposed
above nut (B). Thread nipple (C) into mounting bar (A) and secure with nut
(B). Attach screw collar (H) to nipple (C).
2. Using 2 pairs of pliers, open one link of chain (N) and connect it to the
fixture loop (K) at the top of the fixture.
3. Slide the screw collar ring (F) and canopy (G), in that order, over chain (N).
Open one link on the other end of the chain (N) and attach it to the screw
collar (H) which has been mounted to the ceiling nipple (C).
BE SURE TO CLOSE ALL CHAIN LINKS COMPLETELY.
4. Lace wires up through chain (N) and pass wires through holes in screw
collar (H). We recommend lacing wire up through every other link of chain
(N).
FOR FLUSH MOUNT (FIGURE 3 & 4)
1. Thread fixture mounting screws (BB) in through top of mounting bar (A)
(raised side is on top, as illustrated). Run screw threads (BB) all the way
down to the heads. Secure mounting bar (A) to outlet box with outlet box
screws (not supplied).
FOR SEMI-FLUSH MOUNT
1. Remove fixture loop and top plate. Disconnect wire nuts and remove
hickey and nut. Replace canopy with semiflush canopy. Attach fixture
wires to house supply.
FOR FLUSH MOUNT (FIGURE 3)
1. After wires are connected, tuck them carefully inside outlet box. Raise the
canopy (O) to the ceiling allowing for mounting screws (BB) to protrude
through holes in canopy (O). Secure in place with cap nuts (S).
FINAL INSTALLATION
STEP 1:
Insert diffuser (R) through fixture ring (Q).
STEP 2:
WIRING
A. Use a listed wire connector to connect the fixture hot wire (black wire, or
round and smooth tracer) to the supply hot wire.
B. Use a listed wire connector to connect the fixture common wire (white
wire, or square and rigid) to the supply common wire.
C. Gently try to remove the wires from the connector. If you can remove the
wires, carefully re-do the wiring connection.
Insert short chain (P) through fixture hook (Z).
STEP 3:
Insert lamp(s).
STEP 4:
2. GROUNDING INSTRUCTIONS: The green grounding screw (D) is to be
inserted into the hole with two raised dimples provided on the mounting
bar (A). Wrap the ground wire (E) from the fixture (if supplied) and the
ground wire from the outlet box (bare metal or green insulated wire)
around the green grounding screw (D) on the mounting bar (A) if
uninsulated wire is on the mounting bar (A), connect the ground wire (E)
from the fixture (if supplied) and the outlet box to it using a small wire
connector (not supplied). NEVER CONNECT GROUND WIRE TO BLACK
OR WHITE POWER SUPPLY WIRES.
Insert nipple assembly (M) through diffuser (R). Insert decorative cup (Y)
through nipple (M), secure with finial (AA).
Download PDF