Bistable Relay Station Automation & Protection Types RXPSU6n, RXPSU14n ABB Substation Automation Products RXPSU6n... with 6 free contacts, only one system has contacts; in type PSU14n.. with 14 free contacts, both systems have contacts. In each case two contacts are required for changing over the connection of the coils. Features ! ! ! ! ! High degree of reliability, even when it has been idle for a long time RXPSU14n is with mechanical flag type indicator 6 / 14 contacts with double interruption Contact configuration can be changed with ease Wide range of voltage and contact configuration The contacts are arranged symmetrically on both sides of the relay coil and armature assembly in two stacks. They are easily accessible and the conversion from N/C to N/O contacts and vice versa is simple. The maximum rated voltage is 250V d.c. or a.c. and the material used is hard silver. The following definitions apply for reset and operate condition; reset condition - Armature assembly position is away from the base i.e. the upper system has been pulsed and lower system is ready to be pulsed. The flag strips are invisible i.e. white during this condition. Operate condition - Armature assembly position is closer to the base i.e. the lower system has been pulsed and upper system is ready to be pulsed. The flag strips are visible i.e. red during this condition. Application For remote and automatic control there is often a need for contactors which have two stable contact positions, even in the dead state. This requirement is fulfilled by changeover contactors type RXPSU...n. The application of alternate control pulses to the coils cause the contacts to change from the one state to the other. If the supply is interrupted, the contacts remain in their previous position, even when the voltage is restored. A transparent, incombustible cover with a gasket protects the contacts against dirt. The terminals of the contact stacks themselves permit two wires of 1.5mm diameter maximum to be secured. Changeover relays must always be mounted with the contact post horizontal, that is with the base on a vertical surface. The plug-in relay module occupies two seats (2u 12C). Design and principle The bistable relays in the COMBIFLEX system, type RXPSU6n and RXPSU14n are composed of the same constructional elements as the established contactors type P8n. Two magnet systems are interconnected by a pivoted element. In the type Type designation of auxiliary relays: RXPSU Basic relay with combiflex mounting. 6n with 6 free contacts and without operation indicator 14n with 14 free contacts and operation indicator Technical data Energizing quantities, rated values and limits Rated voltage U N Operative voltage range Permitted ambient temperature range Pick-up voltage (%UN) Pick-up time at UN (typical) Maximum power consumption at the instant of switching Mechanical durability tested acc to IEC 255 Weight Type RXPSU6n Type RXPSU14n Contact data Contact configuration Type RXPSU14n Type RXPSU6n : : : : : : 24, 30, 48, 110, 125, 220, 250 V DC +10%, -20% 0 Deg C to +55 Deg C < 80% 20-40 m sec 65 W 6 : 1 x 10 switching operations, 200 Draw-out / Plug-in operations : 1.3 Kg. approx. : 1.5 Kg. approx. : 7N/O+7N/C, 8N/O+6N/C, 9N/O+5N/C, 10N/O+4N/C, 11N/O+3N/C, 12N/O+2N/C, 13N/O+ 1N/C or 14NO 3N/O+3N/C, 4N/O+2N/C, 5N/O+ 1N/C or 6NO Technical data (cont’d.) Maximum voltage within contacts system Rated current Max. making current Max. Breaking capacities Voltage 24V Contacts 1 : 250V dc/ac : 5A : 50 A 48V 110V 2 in parallel 1 2 in parallel 1 250V 2 in parallel 1 2 in parallel 2 in series DC resistive load 5A 10A 5A 10A 5A 7A 1A - 5A DC inductive. L/R =15ms 5A 10 A 5A 8A 4A - 1A - 4A DC inductive, L/R =40ms 4A 8A 4A 8A 3A - 0.5A - 2A AC resistive & inductive 10 A - 10 A - 10 A - 10A - - Electrical endurance; Tested according to IEC 255-23 Terminals : 0,2 Million operations, at 110 V dc, 0,5A L/R 40 ms. : Suitable for 2x1,5mm2 wires Electrical tests Measurement of resistance; Tested acc. to IEC 255-6 Temperature-rise; Tested acc. to IEC 255-6 Insulation resistance; Tested acc. to IEC 255-5 Dielectric; Tested acc. to IEC 255-5 Impulse; Tested acc. to IEC 255-5 Environmental tests Vibration response; Tested acc. to IEC 255-21-1 Vibration endurance; Tested acc. to IEC 255-21-1 Dry heat; Tested acc. to IEC 68-2-2 Dry cold; Tested acc. to IEC 68-2-1 Damp heat (cyclic - 6days); Tested acc. to IEC 68-2-30 Storage test; Tested acc. To IEC 68-2-48 : +/- 10% of specified : Coil (class F) : >100 M Ohm at 500 V dc : 2,0 kV 50 Hz, 1 min : 5 kV, 1,2/50ms, 0,5J : 10-150Hz; 0.5g; 3 axis : 10-150Hz; 1.0g; 3axis : at +55 Deg C in energized condition : at 0 Deg C : 12 Hr/55 C + 12 Hr/25 C x 2 @ 93% RH : +70 Deg C for 72 Hrs and -25 Deg C for 72 Hrs Ordering details: Relay type Auxiliary voltage Contact configuration Connection diagram and contact configuration 111 111 111 111 211 211 211 211 112 112 112 112 212 212 212 212 213 113 114 214 115 215 116 216 117 217 118 218 113 3NO + 3NC 213 113 114 214 115 215 116 216 117 217 118 218 4NO + 2NC Fig 1 - Relay type RXPSU6n on combiflex mounting. Contact configuration shown for relay in reset position 213 213 113 114 214 114 214 115 215 115 215 116 216 116 216 117 217 117 217 118 218 118 218 5NO + 1NC 6NO 128 228 127 227 128 228 128 228 227 127 227 127 127 227 126 226 125 225 126 226 126 226 126 226 125 225 125 225 125 225 124 123 224 124 224 124 224 124 224 223 123 223 123 223 123 122 222 223 122 222 122 222 122 222 121 221 121 221 121 221 121 221 111 211 111 211 111 211 111 211 228 128 112 112 112 212 212 212 213 113 213 113 114 214 114 214 115 215 115 215 116 216 116 117 217 118 218 113 112 212 213 113 114 214 114 214 115 215 115 215 216 116 216 116 216 117 217 117 217 117 217 118 218 118 218 118 218 7NO + 7NC 9NO + 5NC 8NO + 6NC 213 10NO + 4NC 128 228 128 228 128 228 128 228 127 227 127 227 127 227 127 227 126 226 126 226 126 226 126 226 125 225 125 225 125 225 125 225 124 224 124 224 124 224 124 224 123 223 123 223 123 223 123 223 122 222 122 222 122 222 122 222 121 221 121 221 121 221 121 221 111 211 111 211 111 211 111 211 112 112 112 212 212 212 113 213 114 214 115 215 116 112 212 213 113 213 113 114 214 114 214 114 214 115 215 115 215 115 215 216 116 216 116 216 116 216 117 217 117 217 117 217 117 217 118 218 118 218 118 218 118 218 11NO + 3NC 113 12NO + 2NC Fig 2 - Relay type RXPSU14n on combiflex mounting. Contact configuration shown for relay in reset position 13NO + 1NC 213 14NO Dimensions 74 85 12C 2U 83 175 Fig. 3- Combiflex mounting References Connection and installation components in COMBIFLEX Relay mounting systems 1MRK 513 003-BEN 1MRK 514 001-BEN Ordering Details Refer type designation for selection and mark ( 4 ) appropriate boxes Type : Aux Voltage RXPSU6n Qty.............. : 24VDC Item no......... Contacts 6N/O + 0N/C 30VDC 5N/O + 1N/C 48VDC 4N/O + 2N/C 110VDC 3N/O + 3N/C 125VDC 220VDC 250VDC Type Aux Voltage : RXPSU14n 24VDC Qty.............. Item no......... Contacts 14N/O + 0N/C 30VDC 13N/O + 1N/C 48VDC 12N/O + 2N/C 110VDC 11N/O + 3N/C 125VDC 10N/O + 4N/C 220VDC 9N/O + 5N/C 250VDC 8N/O + 6N/C 7N/O + 7N/C Business Management Meter & Load Management Consulting & Services Network Management Station Automation & Protection Communications 1MDB08205 -YN 12 - 2002 Panorama is the standard for a comprehensive range of integrated solutions for efficient and reliable management of power networks. Using innovative information technology, Panorama delivers total control of the power process, from generation to consumption. The Panorama standard covers six application areas, each offering specific solutions. Asea Brown Boveri Limited Substation Automation Products Maneja, Vadodara 390 013, India. Tel. : 0265-2604386, 2604384, 2604387 Fax : 0265-2638922 E-mail : [email protected]
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement