3.6 3 Control Relays and Timers Solid-State Relays Contents D96 Series—Solid-State Relays Description 3 3 Page D93 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D96 Series V7-T3-127 Product Selection . . . . . . . . . . . . . . . . . . . . V7-T3-135 V7-T3-136 V7-T3-138 V7-T3-139 Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . D99 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3 3 3 3 3 3 D96 Series 3 Product Description Application Description Features and Benefits Eaton’s D96 series of solid-state relays is a technologically advanced set of electronic relays for tough applications and harsh environments. The compact 17.5 mm wide package with an integrated heat sink provides easy mounting in tight spaces. A solid-state relay (SSR) can perform many applications that an electromechanical relay can perform. The SSR differs in that it has no moving mechanical parts within it and has some distinct advantages over an electromechanical relay. ● 3 3 3 3 3 3 3 3 When used correctly in the intended application, the SSR provides a high degree of reliability, a long service life, significantly reduced electromagnetic interference, fast response and high vibration resistance. ● ● ● ● All solid-state circuitry has no moving parts to wear Integral heat sink eliminates the need for added accessories and installation Flexible mounting allows DIN rail or panel mounting without additional hardware or tools Isolated input and output terminals protect the system from electrical noise Internal snubber circuitry protects the SSR from transients Standards and Certifications ● ● ● ● UL/cUL listed—UL 508 CSA certified CE marked RoHS compliant Applications for the SSR typically include equipment that requires high cycling rates, low acoustical or electrical noise, or high vibration resistance. Some examples are medical equipment, heating/cooling equipment, lighting control and pumps/compressors, among others. 3 3 3 3 3 3 3 3 3 3 V7-T3-134 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—June 2013 www.eaton.com www.comoso.com Control Relays and Timers Solid-State Relays 3.6 Product Selection D96115ACZ3 3 D96 Series 3 Input Voltage Output Voltage Contact Configuration Switching Type Rated Current Load (Amps) 3.5–32 Vdc 3–50 Vdc SPST-NO DC switch 15 D96115ACZ3 3.5–32 Vdc 3–150 Vdc SPST-NO DC switch 8 D96208ACZ3 90–280 Vac 24–280 Vac SPST-NO Random 10 D96210ACR1 3–32 Vdc 24–280 Vac SPST-NO Random 10 D96210ACR2 90–280 Vac 24–280 Vac SPST-NO Zero cross 10 D96210ACZ1 3–32 Vdc 24–280 Vac SPST-NO Zero cross 10 D96210ACZ2 Catalog Number 3–32 Vdc 24–280 Vac SPST-NC Random 10 D96210BCR2 90–280 Vac 48–480 Vac SPST-NO Random 10 D96410ACR1 3–32 Vdc 48–480 Vac SPST-NO Random 10 D96410ACR2 90–280 Vac 48–480 Vac SPST-NO Zero cross 10 D96410ACZ1 3–32 Vdc 48–480 Vac SPST-NO Zero cross 10 D96410ACZ2 90–280 Vac 48–600 Vac SPST-NO Random 10 D96610ACR1 90–280 Vac 48–600 Vac SPST-NO Zero cross 10 D96610ACZ1 3–32 Vdc 48–600 Vac SPST-NO Zero cross 10 D96610ACZ2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—June 2013 www.eaton.com www.comoso.com V7-T3-135 3.6 3 3 Solid-State Relays Technical Data and Specifications D96 Series 3 Description 3 Contact configuration Switching device 3 Control Relays and Timers Units D96210ACZ1 D96210ACZ2 D96210ACR1 D96210ACR2 D96115ACZ3 D96208ACZ3 D96210BCR2 SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO SPST-NC SCR SCR SCR SCR MOSFET MOSFET SCR 10 10 10 10 15 8 10 Zero cross Zero cross Random turn on Random turn on DC switching DC switching Random turn on Output Characteristics Current rating A 3 Switching type Maximum zero turn-on voltage (Vpk) V 35 35 35 35 NA NA 35 3 Maximum rate of rise off state voltage (DV/DT) V/us 500 500 500 500 NA NA 500 Incandescent lamp ampere rating (rms) A 8 8 8 8 NA NA 8 3 Motor load rating (rms) A 4.5 4.5 4.5 4.5 NA NA 4.5 Min. load current to maintain on mA 50 50 50 50 20 20 50 Non-repetitive surge current (1 cycle) A 500 500 500 500 50 35 500 3 3 Max. rms overload current (1 second) A 24 24 24 24 24 17 24 Max. off state leakage current (rms) mA 10 10 10 10 10 10 10 3 Typical on state voltage drop (rms) V 1.25 AC 1.25 AC 1.25 AC 1.25 AC 1.25 DC 1.25 DC 1.25 AC Max. on state voltage drop (rms) V 1.6 AC 1.6 AC 1.6 AC 1.6 AC 1.6 DC 1.6 DC 1.6 AC 1250 1250 1250 1250 NA NA 1250 10 AC 1 DC 1 DC 3 3 Max. I2t for fusing (A2) Input Characteristics Must release voltage V 10 AC 1 DC 1 DC 1 DC 3 Typical input impedance ohms 16–25k Current regulator 16–25k ACL Current regulator Current regulator ACL Nominal input current at 5 Vdc or 240 Vac mA 3 Reverse polarity protection 3 12 16 12 16 12 12 12 NA Yes NA Yes Yes Yes Yes Performance Characteristics Operating time (response time) ON ms 40 8.3 8.3 8.3 5 5 8.3 OFF ms 80 8.3 8.3 8.3 5 5 8.3 3 Rated insulation voltage—input to input Vac 2500 2500 4000 4000 2500 2500 4000 Dielectric strength—terminal to chassis Vac 2500 2500 2500 2500 2500 2500 2500 3 Environment UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE –40 to 100 –40 to 100 –40 to 100 –40 to 100 –40 to 100 –40 to 100 –40 to 100 3 3 3 3 Product certifications Ambient air temperature Storage °C Operating °C Degree of protection –30 to 80 –30 to 80 –30 to 80 –30 to 80 –30 to 80 –30 to 80 –30 to 80 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Miscellaneous Characteristics 3 3 Thermal resistance (junction to case) °C/W 0.66 0.66 0.66 0.66 0.66 0.66 0.66 Integral heat sink °C/W 4.0 4.0 4.0 4.0 4.0 4.0 4.0 Weight g (oz) 127 (4.1) 127 (4.1) 127 (4.1) 127 (4.1) 127 (4.1) 127 (4.1) 127 (4.1) Green Green Green Green Green Green Green 3 LED—input Terminal wire capacity AWG (mm2) 14 (2.1) 14 (2.1) 14 (2.1) 14 (2.1) 14 (2.1) 14 (2.1) 14 (2.1) 3 Terminal torque (max.) in-lb (Nm) 7.1 (0.8) 7.1 (0.8) 7.1 (0.8) 7.1 (0.8) 7.1 (0.8) 7.1 (0.8) 7.1 (0.8) 3 3 3 3 V7-T3-136 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—June 2013 www.eaton.com www.comoso.com 3.6 Control Relays and Timers Solid-State Relays Temperature Derating Curves 3 15 Amp Style 35 24 3 30 18 3 15 3 12 3 Current (amps DC) Load Current (amps rms) 8 Amp Style 25 20 15 9 10 8 6 5 3 1.5 0 0° 10° 20° 30° 40° 50° 60° 70° 85° 80° 90° 3 3 3 0 0° Max. Ambient Temperature (°C) 10° 20° 30° 40° 50° 60° 70° 80° 90° 3 Ambient Temperature (°C) 3 3 Load Current (amps rms) 10 Amp Style 14 3 12 3 10 3 8 3 6 3 4 3 1.8 2 3 0 0° 10° 20° 30° 40° 50° 60° 70° 80° 90° 3 Max. Ambient Temperature (°C) 3 3 3 3 3 3 3 3 3 3 3 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—June 2013 www.eaton.com www.comoso.com V7-T3-137 3.6 3 Dimensions 3 D96 Series 3 0.69 (17.6) 3 0.20 (5.0) Control Relays and Timers Solid-State Relays Approximate Dimensions in Inches (mm) 0.20 (5.0) 0.07 (1.7) 3 3 0.56 (14.2) 3 3.54 (90.0) 1.78 (45.3) 3 1.40 (35.6) 3.64 (92.4) 2.63 (66.8) 3 1.39 (35.2) 3 3 3 0.27 (6.9) 3 0.63 (16.0) 1.36 (34.6) 0.13 (3.4) 0.56 (14.3) 2.56 Max. (65.0) 3 0.24 (6.0) 3 3 0.62 (15.8) 0.55 (14.9) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 V7-T3-138 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—June 2013 www.eaton.com www.comoso.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement