Passive network components IWLAN

Passive network components IWLAN
1
Passive network components IWLAN ___________________
Preface
2
___________________
Product overview
SIMATIC NET
Industrial Wireless LAN
Passive network components
IWLAN
System Manual
11/2012
C79000-8976-C282-01
3
___________________
Technical data
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
Order number: C79000-8976-C282-01
Ⓟ 11/2012 Technical data subject to change
Copyright © Siemens AG 2012.
All rights reserved
Table of contents
1
Preface ...................................................................................................................................................... 5
2
Product overview ....................................................................................................................................... 7
3
2.1
2.1.1
2.1.2
Cabling technique ..........................................................................................................................7
Overview ........................................................................................................................................7
Area of application .......................................................................................................................11
2.2
2.2.1
2.2.2
Further passive components........................................................................................................13
Antennas ......................................................................................................................................13
RCoax cables...............................................................................................................................14
2.3
2.3.1
2.3.2
Active components.......................................................................................................................15
Access points ...............................................................................................................................15
Client modules .............................................................................................................................17
Technical data ......................................................................................................................................... 19
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
Flexible connecting cables...........................................................................................................19
Introduction ..................................................................................................................................19
IWLAN N-Connect/R-SMA male/male .........................................................................................20
IWLAN N-Connect male/male......................................................................................................22
IWLAN QMA/N-Connect male/female .........................................................................................24
IWLAN R-SMA/SMA male/male...................................................................................................26
3.2
3.2.1
3.2.2
Terminating resistors ...................................................................................................................28
N terminating resistance 50 Ω – male..........................................................................................28
R-SMA terminating resistor 50 Ω – male .....................................................................................30
3.3
3.3.1
3.3.2
Lightning protectors .....................................................................................................................32
Lightning protector LP798-1N ......................................................................................................32
Lightning protector LP798-2N ......................................................................................................34
3.4
3.4.1
3.4.2
Panel feedthroughs......................................................................................................................36
Panel feedthrough N-Connect female/female..............................................................................36
Panel feedthrough N/SMA female/female ...................................................................................38
3.5
Attenuator N-Connect male/female .............................................................................................40
3.6
Power splitter N-Connect female .................................................................................................42
3.7
HF coupler N-Connect male/male................................................................................................44
Index........................................................................................................................................................ 45
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
3
Table of contents
Passive network components IWLAN
4
System Manual, 11/2012, C79000-8976-C282-01
1
Preface
Purpose of the system manual
This manual explains the entire IWLAN cabling that you require for your IWLAN application.
For a flexible combination and installation of the individual IWLAN components both indoors
and outdoors, a wide ranging selection of compatible coaxial accessories is available. The
manual also covers connecting cables as well as a variety of plug-in connectors, lightning
protectors, a power splitter and an attenuator.
Figure 1-1
IWLAN product overview
Certification
The products and systems listed in this document are manufactured and marketed using a
quality management system complying with DIN ISO 9001 (Certificate Register no. 2613)
and certified by DQS. The DQS certificate is recognized in all IQNet countries (reg. no.:
2613).
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
5
Preface
SIMATIC NET glossary
Explanations of the specialist terms used in this documentation can be found in the SIMATIC
NET glossary.
You will find the SIMATIC NET glossary here:
● SIMATIC NET Manual Collection
The DVD ships with certain SIMATIC NET products.
● On the Internet under the following entry ID:
50305045 (http://support.automation.siemens.com/WW/view/en/50305045)
Passive network components IWLAN
6
System Manual, 11/2012, C79000-8976-C282-01
Product overview
2.1
Cabling technique
2.1.1
Overview
2
The following passive IWLAN components are available:
Flexible connecting cables
SIEMENS IWLAN RCoax N-Connect/N-Connect male/male
Flexible connecting cable for linking two RCoax cables or an antenna
to a SCALANCE W700 access point with N-Connect connectors.
Preassembled with two N male connectors:

6XV1 875-5AH10 (length 1 m)

6XV1 875-5AH20 (length 2 m)

6XV1 875-5AH50 (length 5 m)

6XV1 875-5AN10 (length 10 m)
SIEMENS IWLAN QMA/N-Connect male/female
Adapter cable for connecting a MIMO antenna with QMA connectors
with the flexible connecting cables. Preassembled with two
connectors QMA male and N-Connect female:

6XV1 875-5JH10 (length 1 m)
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
7
Product overview
2.1 Cabling technique
SIEMENS SIMATIC NET IWLAN RCoax/Antenna Connection Cable
R-SMA/SMA male/male
Flexible connecting cable for connecting a SCALANCE W7xx or
IWLAN/PB Link PN IO to components with R-SMA and SMA
connectors, for example cabinet feedthrough.
Preassembled with two connectors R-SMA male and SMA male:

6XV1 875-5DE30 (length 0.3 m)

6XV1 875-5DH20 (length 2 m)
SIEMENS SIMATIC NET IWLAN RCoax/Antenna Connection Cable
N-Connect/RSMA male/male
Flexible connecting cable for connecting an RCoax cable or an
antenna to a SCALANCE W7xx. Preassembled with two connectors
N male and R-SMA male:

6XV1 875-5CE30 (length 0.3m)

6XV1 875-5CH10 (length 1 m)

6XV1 875-5CH20 (length 2 m)

6XV1 875-5CH50 (length 5 m)

6XV1 875-5CN10 (length 10 m)
Terminating resistors
SIEMENS SIMATIC NET IWLAN RCoax N-Connect Male
Termination Impedance 50 Ω TI795-1N
Terminating impedance for RCoax cables and open wireless
interfaces on SCALANCE W700 devices with N-Connect
connectors, impedance 50 ohms,

6GK5 795-1TN00-1AA0
SIEMENS SIMATIC NET IWLAN Termination Impedance
TI795-1R
R-SMA terminator for fitting to the unused antenna socket of a
SCALANCE W7xx when using one antenna only. Impedance 50
Ω, R-SMA male connector.

6GK5 795-1TR10-0AA6
Passive network components IWLAN
8
System Manual, 11/2012, C79000-8976-C282-01
Product overview
2.1 Cabling technique
Lightning protectors
SIEMENS SIMATIC NET IWLAN Lightning Protector with N/N
female/female connector LP 798-2N
Lightning protector with maintenance-free quarter-wave
technology for frequencies in the range 2 to 6 GHz.

6GK5798-2LP10-2AA6
SIEMENS SIMATIC NET IWLAN Lightning Protector with N/N
female/female connector LP 798-1N
Lightning protector with gas discharge capsule, also suitable for
DC current on the antenna cable. 0 to 6 GHz.

6GK5798-2LP00-2AA6
Panel feedthroughs
SIEMENS SIMATIC NET IWLAN Antenna N-Connect/NConnect female/female Panel Feedthrough
Panel feedthrough/adapter N-N for wall thicknesses up to a
maximum of 4.5 mm, N-Connect/N-Connect connectors

6GK5 798-2PP00-2AA6
SIEMENS SIMATIC NET IWLAN RCoax N-Connect/SMA
female/female Panel Feedthrough
Panel feedthrough with securing flange for wall thicknesses up
to a maximum of 5.5 mm, SMA female and N-Connect female
connectors

6GK5 798-0PT00-2AA0
Attenuator
SIEMENS SIMATIC NET IWLAN RCoax N-Connect
Male/Female Attenuator 10 dB
Attenuator with N-Connect male / N-Connect female
connectors

6GK5 798-0AP00-4CA0
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
9
Product overview
2.1 Cabling technique
Power splitter
SIEMENS SIMATIC NET IWLAN RCoax N-Connect Female
Power Splitter 2-Way
Two-way power splitter, Y element for splitting the RCoax cable
or for the use of two antennas on one wireless interface.

6GK5 798-0SN00-0EA0
HF coupler
RCoax N-Connect male/male Coupler
HF coupler, among other things for connecting two RCoax
cables; two N-Connect male connectors.

6GK5 798-0CP00-1AA0
Passive network components IWLAN
10
System Manual, 11/2012, C79000-8976-C282-01
Product overview
2.1 Cabling technique
2.1.2
Area of application
Flexible connecting cables
● The flexible IWLAN RCoax/antenna connecting cables are required for connecting RCoax
segments or antennas to active devices.
● The cables provide low attenuation so that the quality of the wireless signal is only
minimally impaired.
● The antenna cables are flame retardant, chemical resistant and silicone-free.
Terminating resistors
● To avoid impairing wireless quality, terminating resistors are required to close unused
antenna connectors on the access points and clients.
● RCoax segments must be terminated at the end with a terminating resistor.
Lightning protectors
When using separate antennas outdoors, there is a risk of lightning strikes. To protect the
equipment, a lightning protector can be used.
Panel feedthroughs
The panel feedthroughs along with the antenna connecting cables allow simple connection
of separately installed antennas and the active components installed in cabinets or cubicles.
Attenuator
The 10 dB attenuator is always used when the transmitted power both in the send and
receive direction needs to be reduced. Typical areas of application are short RCoax
segments or directional wireless links that need to be restricted in terms of spread.
Power splitter
With the aid of the power splitter, the transmit power of an access point is distributed over
two RCoax or antenna segments. This allows wireless coverage in two different areas with
only one access point.
Product variants
Flexible connecting cables
● Preassembled cable lengths (0.3 m to 10 m)
● Different connector types and combinations:
– N-Connect
– R-SMA
– SMA
– QMA
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
11
Product overview
2.1 Cabling technique
Terminating resistors
● TI795-1R: Terminating resistor for R-SMA antenna sockets
● TI795-1N: Terminating resistor for N-Connect antenna sockets or RCoax segments
Lightning protectors
● LP798-2N
Maintenance-free lightning protector for N-Connect connectors:
– Quarter wave technology (lambda quarter) for the frequency range 2 to 6 GHz
– forms a short circuit for direct voltages so that all kinds of overvoltages can be diverted
reliably
– not suitable for DC supply via antenna cable
● LP798-1N
Lightning protector for N-Connect connectors:
– with gas discharge protector for the frequency range 0 to 6 GHz for N-Connect
connectors
– suitable for DC supply via antenna cable
Panel feedthroughs
● N-Connect female/SMA female with securing flange for wall thicknesses up to a
maximum of 5.5 mm
● N-Connect female/N-Connect female without flange for wall thicknesses up to a
maximum of 4.5 mm. This can also be used as a link between two antenna connecting
cables.
This section introduces you to the IWLAN products. You will find technical specifications in
the section "Technical data (Page 19)".
Passive network components IWLAN
12
System Manual, 11/2012, C79000-8976-C282-01
Product overview
2.2 Further passive components
2.2
Further passive components
2.2.1
Antennas
Product connections
The products described up to now are used to connect the following passive components to
access points and clients:
Component
Description
Order number
IWLAN RCoax N-Connect
Female Antenna ANT792-4DN
RCoax helical antenna with circular polarization for
RCoax systems, 2.4 GHz.
6GK5 792-4DN00-0AA6
ANT792-6MN
Omnidirectional antenna with N connector female
2.4 GHz
6GK5 792-6MN00-0AA6
ANT792-8DN
Directional antenna with N connector female
2.4 GHz
6GK5 792-8DN00-0AA6
ANT795-4MA
Omnidirectional antenna with R-SMA connector,
2.4 GHz / 5 GHz
Radial rotation with additional joint
6GK5 793-4MA00-0AF3
ANT795-4MC
Omnidirectional antenna with N-Connector male
2.4 GHz / 5 GHz
6GK5 793-4MC00-0AF3
ANT795-4MD
Omnidirectional antenna with N-Connector male
2.4 GHz / 5 GHz
6GK5 793-4MD00-0AF3
IWLAN RCoax N-Connect
Female Antenna ANT793-4MN
RCoax λ5/8 antenna with vertical polarization for
RCoax systems, 5 GHz.
6GK5 793-4MN00-0AA6
ANT795-6DC
Dual-band directional antenna with linear polarization
2.4 GHz / 5 GHz
6GK5 793-6DC00-0AA0
ANT793-6DG
Dual directional antenna with linear polarization and
polarization levels at ±45°, 5 GHz.
6GK5 793-6DG00-0AA0
ANT793-6DT
MIMO antenna with three QMA connectors and three
polarization levels (vertical and ±45°), 5 GHz.
6GK5 793-6DT00-0AA0
ANT793-6MN
Omnidirectional antenna with N connector female
5 GHz
6GK5 793-6MN00-0AA6
ANT795-6MT
MIMO antenna with three QMA connectors
2.4 GHz / 5 GHz
6GK5 793-6MT00-0AA0
ANT793-8DJ
Directional antenna with dual horizontal/vertical
polarization
5 GHz
6GK5 793-8DJ00-0AA0
ANT793-8DK
Directional antenna with dual horizontal/vertical
polarization
5 GHz
6GK5 793-8DK00-0AA0
ANT793-8DN
Directional antenna with N connector female
5 GHz
6GK5 793-8DN00-0AA6
ANT795-4MR
Omnidirectional antenna with R-SMA connector for
direct mounting on a SCALANCE W700, 2.4 GHz /
5 GHz
6GK5 795-4MR00-0AA6
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
13
Product overview
2.2 Further passive components
Component
Description
Order number
ANT795-4MS
Omnidirectional antenna with R-SMA connector for
direct mounting on a SCALANCE W700, 2.4 GHz /
5 GHz
Radial rotation with additional joint.
6GK5 795-4MS00-0AA6
ANT795-6DN
Directional antenna with N connector female
2.4 GHz / 5 GHz
6GK5 795-6DN00-0AA6
ANT795-6MN
Omnidirectional antenna for roof mounting or mounting
on vehicles
2.4 GHz / 5 GHz
6GK5 795-6MN00-0AA6
Note
You will find further information in the compact operating instructions of the individual
components.
2.2.2
RCoax cables
Component
Description
Order number
IWLAN RCoax cable
Leaky feeder for areas with difficult wireless conditions as a
special antenna for SCALANCE W access points. For the
expanded temperature range (-40 °C to +85 °C). Sold by the
meter, minimum order 20 meters.
2.4 GHz
6XV1 875-2A
5 GHz
6XV1 875-2D
Note
Further information
You will find further information in the system manual for RCoax.
Passive network components IWLAN
14
System Manual, 11/2012, C79000-8976-C282-01
Product overview
2.3 Active components
2.3
Active components
2.3.1
Access points
SCALANCE W78x
The SCALANCE W78x access points with one or more wireless interfaces are suitable for
setting up Industrial Wireless LANs. Both infrastructure networks and point-to-point links can
be implemented. The most important characteristics of the various product variants are
shown in the table below. You will find detailed information in the documentation of the
relevant device.
Type
Connectors for
external antennas
R-SMA
N-Connect
W788-1 M12
Number of
connectable
devices (3)
3
iPCF
mode (1)
8
IEEE
802.11
a/b/g/h
●
IEEE
802.11n
3x3
Order no.
6GK5 788-1GD00-0AA0
6GK5 788-1GD00-0AB0
W788-2 M12
6
8
●
3x3
6GK5 788-2GD00-0AA0
6GK5 788-2GD00-0AB0
W788-1 RJ-45
3
8
●
3x3
W788-2 RJ-45
6
8
●
3x3
W786-1 RJ-45
3
8
●
3x3
W786-2 RJ-45
6
8
●
3x3
6GK5 786-2FC00-0AA0
8
●
3x3
6GK5 786-2HC00-0AA0
6GK5 786-2FC00-0AB0
6GK5 786-2HC00-0AB0
W786-2 SFP
6
8
●
3x3
6GK5 786-1FE00-0AA0
W788C-2 RJ45
6
8
●
3x3
6GK5 788-2FC00-0AA0
W788C-2 M12
6
8
●
3x3
6GK5 788-2GD00-0AA0
W786C-2 RJ45
6
8
●
3x3
6GK5 786-2FC00-0AA0
8
●
3x3
6GK5786-2HC00-0AA0
8
●
2
(2)
6GK5786-1FC00-0AA0
6GK5786-1FC00-0AB0
W788-1PRO
(2)
6GK5 788-2FC00-0AA0
6GK5 788-2FC00-0AB0
W786C-2IA
RJ-45
(2)
6GK5788-1FC00-0AA0
6GK5 788-1FC00-0AB0
W786-2IA RJ45
(2)
(2)
(2)
(2)
6GK5 788-1AA60-2AA0
6GK5 788-1AA60-2AB0 (2)
W788-2PRO
4
8
●
6GK5 788-2AA60-2AA0
6GK5 788-2AA60-2AB0 (2)
W788-1RR
2
8
●
●
6GK5 788-1AA60-6AA0
6GK5 788-1AA60-6AB0 (2)
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
15
Product overview
2.3 Active components
Type
Connectors for
external antennas
R-SMA
W788-2RR
N-Connect
4
Number of
connectable
devices (3)
8
iPCF
IEEE
mode (1) 802.11
a/b/g/h
●
IEEE
802.11n
●
Order no.
6GK5 788-2AA60-6AB0
6GK5 788-2SR00-2AA6 (2)
W786-1PRO
4
8
●
6GK5 786-1AA60-2AA0
6GK5 786-1AA60-2AB0 (2)
W786-2PRO
4
8
●
6GK5 786-2AA60-2AA0
6GK5 786-2AA60-2AB0 (2)
W786-2RR
4
4
8
●
●
6GK5 786-2AA60-6AA0
6GK5 786-2AA60-6AB0 (2)
W786-3PRO
6
8
●
6GK5 786-3AA60-2AA0
6GK5 786-3AB60-2AB0 (2)
W784-1
2
8
W784-1RR
2
8
W786-2HPW
4
8
●
6GK5 784-1AA30-2AA0
6GK5 784-1AA30-2AB0 (2)
●
●
6GK5 784-1AA30-6AA0
6GK5 784-1AA30-6AB0 (2)
●
6GK5 786-2AA60-1CA0
6GK5 786-2AB60-1CA0
6GK5 786-2BA60-1CA0
6GK5 786-2BB60-1CA0
● suitable
(1) The iPCF mode provides an optimized data throughput and minimum handover times.
(2) US variant
(3) In client mode
Passive network components IWLAN
16
System Manual, 11/2012, C79000-8976-C282-01
Product overview
2.3 Active components
2.3.2
Client modules
SCALANCE W74x
The SCALANCE W74x client modules establish a connection between wired Ethernet and
Industrial Wireless LAN. The most important characteristics of the various product variants
are shown in the table below. You will find detailed information in the documentation of the
relevant device.
Type
Connectors for external
antennas
R-SMA
W748-1
M12
N-Connect
Number of
connectable
devices (3)
3
iPCF mode IEE
802.11
(1)
a/b/g/h
IEEE
802.11n
Order no.
8
●
3x3
6GK5 748-1GD00-0AA0
3x3
6GK5 748-1FC00-0AA0
6GK5 748-1GD00-0A B0 (2)
W748-1
RJ-45
3
8
●
W7441PRO
2
1
●
W7461PRO
2
W747-1RR
2
6GK5 748-1FC00-0A B0 (2)
6GK5 744-1AA60-2AA0
6GK5 744-1AA60-2AB0 (2)
8
●
6GK5 746-1AA60-4AA0
6GK5 746-1AA60-4AB0 (2)
8
●
●
6GK5 747-1AA60-6AA0
6GK5 747-1AA60-6AB0 (2)
W744-1
2
1
●
6GK5 744-1AA30-2AA0
6GK5 744-1AA30-2AB0 (2)
W746-1
2
8
●
6GK5 746-1AA30-4AA0
6GK5 746-1AA30-4AB0 (2)
W747-1
2
8
●
●
6GK5 747-1AA30-6AA0
6GK5 747-1AA30-6AB0 (2)
● suitable
(1) The iPCF mode provides an optimized data throughput and minimum handover times.
(2) US variant
(3) In client mode
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
17
Product overview
2.3 Active components
IWLAN/PB Link PN IO
IWLAN/PB Link PN IO is a gateway that connects the two network types PROFIBUS and
Industrial Wireless LAN. IWLAN/PB Link PN IO supports access to all PROFIBUS DP slaves
connected to PROFIBUS. For more detailed information, please refer to the manual C79000G8976-C200.
Mobile Panel 277 IWLAN
The Mobile Panel is a mobile HMI device for tasks of medium complexity for use in
PROFIBUS DP networks or in PROFINET environments. Apart from the standard HMI
functionality, the range of applications can be expanded by the WinCC flexible options Smart
Access, Smart Service and Audit.
ET 200pro IWLAN
The SIMATIC ET 200pro is an I/O system that can be mounted directly on the machine. To
achieve this, various interface modules are available for connection to PROFINET or
PROFIBUS both in standard and fail-safe versions. For communication between the ET
200pro and higher-level controllers via Industrial Wireless LAN (IWLAN) networks, you
require an interface module.
Type
Connectors for external iPCF mode (1)
antennas
R-SMA
IWLAN/PB
Link PN IO
Mobile Panel
277 (F) IWLAN
N-Connect
1
●
IEEE
802.11
a/b/g/h
Order no.
IEEE
802.11n
●
6GK1 417-5AB00
6GK1 417-5AB01(2)
2
●
●
Mobile Panel 277 IWLAN

6AV6645-0Dxxx-xxx1
 6AV6645-0Fxxx-xxx1 (2)
Mobile Panel 277F IWLAN
Interface module
IM 154-6 PN HF
IWLAN
2
●
●

6AV6645-0Exxx-xxx1

6AV6645-0Gxxx-xxx1 (2)
6ES7 154-6AB00-0AB0
6ES7 154-6AB50-0AB0(2)
● suitable
(1) The iPCF mode provides an optimized data throughput and minimum handover times.
(2) US variant
Passive network components IWLAN
18
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.1
Flexible connecting cables
3.1.1
Introduction
3
Note
The flexible connecting cable is intended for connection of fixed and mobile users where the
permitted bend radiuses are only seldom reached.
(Examples:
 Connection of a client on a vehicle, where the cable vibrates but is not permanently bent.
 Connection of an antenna to an access point when the antenna is occasionally aligned so
that the cable position is changed.
The flexible connecting cable is not designed for continuous bending or twisting.
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
19
Technical data
3.1 Flexible connecting cables
3.1.2
IWLAN N-Connect/R-SMA male/male
IWLAN N-Connect/R-SMA male/male
Flexible connecting cable for connecting an RCoax cable or an antenna to a SCALANCE
W700 access point with R-SMA connectors. Preassembled with two connectors N-Connect
male and R-SMA male.
Technical specifications
Order numbers
0.3 m
6XV1 875-5CE30
1m
6XV1 875-5CH10
2m
6XV1 875-5CH20
5m
6XV1 875-5CH50
10 m
6XV1 875-5CN10
Electrical data
Impedance
50 Ω
Ratio of propagation speed
82 %
Capacitance
82 pF/m
Return loss
≥ 23 dB
Frequency
Attenuation (1)
≤ 6 GHz
at 2.4 GHz
0.53 dB/m
at 5.1 GHz
0.83 dB/m
at 5.7 GHz
0.88 dB/m
Resistance to fire
Flame retardant
UL 1685 (vertical tray) and UL 1581, Sec. 1090 (H)
Dimensions, materials and weight
Number of plug-in connections
2
Outer diameter
6.3 mm
Materials
Inner conductor
Dielectric
Inner metal screen
Outer metal shield

Silver-coated copper

Diameter: 1.4 mm

Polyethylene foam

Diameter: 3.8 mm

Tin plated copper wires with a wire diameter of 0.13
mm

Area coverage 95%

Diameter: 4.3 mm

Tin plated copper wires with a wire diameter of 0.13
mm

Area coverage 95%

Diameter: 4.8 mm
Passive network components IWLAN
20
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.1 Flexible connecting cables
Technical specifications
Cable jacket

Thermoplastic copolymer,pastel turquoise

Diameter: 6.3 mm

Jacket thickness: 0.76 mm
Degree of protection
IP67
Silicone-free
yes
Halogen-free
yes
UV resistant
resistant
Weight
0.075 kg/m
Permitted ambient conditions
Ambient temperature
-40 °C ... +80 °C
Mechanical data
Smallest bend
radius
Tensile strength
when bending once
3.2 cm
when bending more
than once
4.5 cm
30 ... 80 N
(1) The specified attenuation values relate only to the cable without connectors. For the assembled
cable, approximately 0.1dB at 2.4 GHz and approximately 0.3 dB at 5 GHz must be added per
plug-in connector.
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
21
Technical data
3.1 Flexible connecting cables
3.1.3
IWLAN N-Connect male/male
IWLAN N-Connect/N-Connect male/male
Flexible connecting cable for connecting an RCoax cable or an antenna to a SCALANCE
W700 access point with N-Connect connectors.
Technical specifications
Order numbers
1m
6XV1 875-5AH10
2m
6XV1 875-5AH20
5m
6XV1 875-5AH50
10 m
6XV1 875-5AN10
Electrical data
Impedance
50 Ω
Ratio of propagation speed
82 %
Capacitance
82 pF/m
Return loss
≥ 23 dB
Frequency
≤ 6 GHz
Attenuation (1)
at 2.4 GHz
0.53 dB/m
at 5.1 GHz
0.83 dB/m
at 5.7 GHz
0.88 dB/m
Resistance to fire
Flame retardant
UL 1685 (vertical tray) and UL 1581, Sec. 1090 (H)
Dimensions, materials and weight
Number of plug-in connections
2
Outer diameter
6.3 mm
Materials

Silver-coated copper

Diameter: 1.4 mm

Polyethylene foam

Diameter: 3.8 mm

Tin plated copper wires with a wire diameter of 0.13 mm

Area coverage 95%

Diameter: 4.3 mm

Tin plated copper wires with a wire diameter of 0.13 mm

Area coverage 95%

Diameter: 4.8 mm

Thermoplastic copolymer,pastel turquoise

Diameter: 6.3 mm

Jacket thickness: 0.76 mm
Inner conductor
Dielectric
Inner metal screen
Outer metal shield
Cable jacket
Degree of protection
IP67
Silicone-free
yes
Passive network components IWLAN
22
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.1 Flexible connecting cables
Technical specifications
Halogen-free
yes
UV resistant
resistant
Weight
0.075 kg/m
Permitted ambient conditions
Ambient temperature
-40 °C ... +80 °C
Mechanical data
Smallest
bend
radius
when bending once
3.2 cm
when bending more than 4.5 cm
once
Tensile strength
30 ... 80 N
(1) The specified attenuation values relate only to the cable without connectors. For the assembled
cable, approximately 0.1dB at 2.4 GHz and approximately 0.3 dB at 5 GHz must be added per
plug-in connector.
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
23
Technical data
3.1 Flexible connecting cables
3.1.4
IWLAN QMA/N-Connect male/female
IWLAN QMA/N-Connect male/female
Flexible adapter cable for connecting a MIMO antenna with QMA connectors.
Technical specifications
Order number
1 m (pack of 3)
6XV1 875-5JH10
Electrical data
Impedance
50 Ω
Ratio of propagation speed
82 %
Capacitance
82 pF/m
Return loss
≥ 23 dB
Frequency
≤ 6 GHz
Attenuation (1)
at 2.4 GHz
0.53 dB/m
at 5.1 GHz
0.83 dB/m
at 5.7 GHz
0.88 dB/m
Resistance to fire
Flame retardant
UL 1685 (vertical tray) and UL 1581, Sec. 1090 (H)
Dimensions, materials and weight
Number of plug-in connections
2
Outer diameter
6.3 mm
Materials
Inner conductor
Dielectric
Inner metal screen
Outer metal shield
Cable jacket

Silver-coated copper

Diameter: 1.4 mm

Polyethylene foam

Diameter: 3.8 mm

Tin plated copper wires with a wire diameter of 0.13
mm

Area coverage 95%

Diameter: 4.3 mm

Tin plated copper wires with a wire diameter of 0.13
mm

Area coverage 95%

Diameter: 4.8 mm

Thermoplastic copolymer,pastel turquoise

Diameter: 6.3 mm

Jacket thickness: 0.76 mm
Degree of protection
IP67
Silicone-free
yes
Halogen-free
yes
UV resistant
resistant
Passive network components IWLAN
24
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.1 Flexible connecting cables
Technical specifications
Weight
0.075 kg/m
Permitted ambient conditions
Ambient temperature
-40 °C ... +80 °C
Mechanical data
Smallest bend
radius
Tensile strength
when bending once
3.2 cm
when bending more
than once
4.5 cm
30 ... 80 N
(1) The specified attenuation values relate only to the cable without connectors. For the assembled
cable, approximately 0.1dB at 2.4 GHz and approximately 0.3 dB at 5 GHz must be added per
plug-in connector.
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
25
Technical data
3.1 Flexible connecting cables
3.1.5
IWLAN R-SMA/SMA male/male
IWLAN R-SMA/SMA male/male
Flexible connecting cable for connecting an active device to components with R-SMA and
SMA connectors, for example panel feedthrough. Assembled with two connectors R-SMA
male to SMA male.
Technical specifications
Order numbers
0.3 m
6XV1 875-5DE30
2m
6XV1 875-5DH20
Electrical data
Impedance
50 Ω
Ratio of propagation speed
82 %
Capacitance
82 pF/m
Return loss
≥ 23 dB
Frequency
≤ 6 GHz
Attenuation (1)
at 2.4 GHz
0.53 dB/m
at 5.1 GHz
0.83 dB/m
at 5.7 GHz
0.88 dB/m
Resistance to fire
Flame retardant
UL 1685 (vertical tray) and UL 1581, Sec. 1090 (H)
Dimensions, materials and weight
Number of plug-in connections
2
Outer diameter
6.3 mm
Materials
Inner conductor
Dielectric
Inner metal screen
Outer metal shield
Cable jacket

Silver-coated copper

Diameter: 1.4 mm

Polyethylene foam

Diameter: 3.8 mm

Tin plated copper wires with a wire diameter of 0.13
mm

Area coverage 95%

Diameter: 4.3 mm

Tin plated copper wires with a wire diameter of 0.13
mm

Area coverage 95%

Diameter: 4.8 mm

Thermoplastic copolymer,pastel turquoise

Diameter: 6.3 mm

Jacket thickness: 0.76 mm
Passive network components IWLAN
26
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.1 Flexible connecting cables
Technical specifications
Degree of protection
IP67
Silicone-free
yes
Halogen-free
yes
UV resistant
resistant
Weight
0.075 kg/m
Permitted ambient conditions
Ambient temperature
-40 °C ... +80 °C
Mechanical data
Smallest bend
radius
Tensile strength
when bending once
3.2 cm
when bending more
than once
4.5 cm
30 ... 80 N
(1) The specified attenuation values relate only to the cable without connectors. For the assembled
cable, approximately 0.1dB at 2.4 GHz and approximately 0.3 dB at 5 GHz must be added per
plug-in connector.
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
27
Technical data
3.2 Terminating resistors
3.2
Terminating resistors
3.2.1
N terminating resistance 50 Ω – male
Technical specifications
Order number
6GK5 795-1TN00-0AA6
Electrical data
Standing wave ratio
(VSWR)
f [GHz]
2.0
2.4
4.0
6.0
Return flow attenuation
[dB]
> 35
> 30
> 30
> 35
VSWR
< 1,036
< 1,064
< 1,064
< 1,118
Frequency range
≤ 6 GHz
Impedance
50 Ω
Return loss
< 25 dB/6 GHz
Power range
<1W
Dimensions, materials and weight
Number of plug-in connections
1
Dimensions (length x diameter)
34.5 x 21 mm
Materials

Core material: CuZn39Pb3

Coating: Cu2Ag5

Core material: CuZn39Pb3

Coating: CuSnZn3

Core material: CuZn39Pb3

Coating: CuSnZn3

PTFE

Silicone-free

WBR

Silicone-free
Inner conductor
Outer conductor
Other metal parts
Insulation
Seal
Weight
45 g
Degree of protection
IP65
Permitted ambient conditions
Ambient temperature
During operation
-40 °C ... +70 °C
During storage
-40 °C ... +70 °C
During transportation
-40 °C ... +70 °C
Passive network components IWLAN
28
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.2 Terminating resistors
34.5
15.5
Ø20.8
5/8-24 UNEF
Dimension drawing
SW19
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
29
Technical data
3.2 Terminating resistors
3.2.2
R-SMA terminating resistor 50 Ω – male
Technical specifications
Order number
6GK5 795-1TR10-0AA6
Electrical data
Frequency range
≤ 6 GHz
Impedance
50 Ω
Return loss
< 25 dB/6 GHz
Power range
<1W
Dimensions, materials and weight
Number of plug-in connections
1
Dimensions (length x diameter)
15 x 9 mm
Materials

Core material: CuBe2

Coating: Cu1Ni2Au1.27

Core material: CuZn39Pb3

Coating: Cu1Ni2Au1.27

Core material: CuZn39Pb3

Coating: Cu2Ni5Au0.8

PTFE

Silicone-free

WBR

Silicone-free
Inner conductor
Outer conductor
Other metal parts
Insulation
Seal
Weight
5g
Degree of protection
IP65
Permitted ambient conditions
Ambient temperature
During operation
-40 °C ... +70 °C
During storage
-40 °C ... +70 °C
During transportation
-40 °C ... +70 °C
Passive network components IWLAN
30
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.2 Terminating resistors
Dimension drawing
Ø7.8
Ø3
Ø6.5
SW8
3
2
6
15
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
31
Technical data
3.3 Lightning protectors
3.3
Lightning protectors
3.3.1
Lightning protector LP798-1N
Note
We recommend that you use the new lightning protector LP798-2N with lower residual
voltage.
Exception:
When there is also DC power is supplied via the antenna cable. In this case, only the
lightning protector LP798-1N can be used.
Technical specifications
Order number
6GK5 798-2LP00-2AA6
Electrical data
Frequency range
0 ... 6 GHz
Impedance
50 Ω
Operating voltage
< 36 V
Design, dimensions and weight
Number of plug-in connections
2
Design of the plug-in connector
N-Connector female / female
Dimensions (length x diameter)
54.8 x ∅22.8 mm
Materials
Silicone-free
Degree of protection
IP67
Weight
50 g
Permitted ambient conditions
Ambient temperature
-40 °C... + 85 °C
Passive network components IWLAN
32
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.3 Lightning protectors
54,8
22
Ø22,8
24,5
5/8-24 UNEF
5/8-24 UNEF
Dimension drawing
antenne
SW 13,5
SCALANCE W7xx
extencion cabel
max. 8
SW 19
Dimension drawing through hole
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
33
Technical data
3.3 Lightning protectors
3.3.2
Lightning protector LP798-2N
Technical specifications
Order number
6GK5 798-2LP10-2AA6
Electrical data
Frequency range
2 ... 6 GHz
Impedance
50 Ω
Return loss
≥ 20 dB
Insertion loss
≤ 0.2 dB
RF CW power
≤ 300 W
Peak current capacity
test pulse 8/20 μs
50 kA
Residual pulse energy
(test pulse 4 kV 1.2/50 μs or 2 kA 8/20 μs)
0.2 μJ
Starting voltage
150 ... 250 VDC (100 V/s)
Dimensions, materials and weight
Number of plug-in connections
2
Design of the plug-in connector
N-Connector female / female
Dimensions (length x diameter)
89.6 x ∅29 mm
Materials
Housing material
Aluminum
Contacts
Copper beryllium alloy with gold coating
Silicone-free
Meets 2002/95/EC (RoHS)
Degree of protection
IP68
Weight
80 g
Permitted ambient conditions
Ambient temperature
-40 °C ... + 85 °C
Mechanical data
Ports
N/N female/female
Maximum possible number of assembly procedures
100
Passive network components IWLAN
34
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.3 Lightning protectors
Dimension drawing LP798-2N and through hole
89,6
35
SW 25
3/4-28 UN-2A
Ø29
Ø19,3
max. 5
17,2
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
35
Technical data
3.4 Panel feedthroughs
3.4
Panel feedthroughs
3.4.1
Panel feedthrough N-Connect female/female
Panel feedthrough for wall thicknesses up to a maximum of 4.5 mm, two N-Connect female
connectors.
Technical specifications
Order number
6GK5 798-2PP00-2AA0
Electrical data
Frequency range
≤ 11 GHz
Characteristic impedance
50 Ω
Contact resistance
Standing wave ratio
(VSWR)
Inner conductor
≤ 2 mΩ
Outer conductor
≤ 0.5 mΩ
f [GHz]
1
2
4
10
VSWR
1.018
1.020
1.036
1.094
Recommended coupling torque
4 ... 6 Nm
Service life (insertions)
≥ 500
Dimensions and materials
Dimensions (length x diameter)
38 x ø20.7
Materials
Inner conductor
Cu2Ag5
Outer conductor

Core material: CuZn39Pb3

Coating:
Metallic parts
Insulation
–
CuSnZn3 (Telealloy)
–
Ag2CuSnZn0.5 (Optargen)

Core material:

Coating:
PTFE
Seal
Silicone-free
Spring contacts
CuBe2, CuPb1.15Ni1 (C97)
Other metal parts

Core material: CuZn39Pb3

Coating:
–
CuSnZn3 (Telealloy)
–
Cu2Ni5
Meets 2002/95/EC (RoHS)
Degree of protection
IP68
Permitted ambient conditions
Ambient temperature
-30°C... +100 °C
Passive network components IWLAN
36
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.4 Panel feedthroughs
Note
The N-N adapter also be used as a coupler between two IWLAN RCoax / antenna
connecting cables.
Dimension drawing of the feedthrough and through hole
38
max. 4,5
SW 13,5
Ø16,2
Ø20,7
13,7
5/8-24
UNEF
5/8-24
UNEF
21
SW 19
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
37
Technical data
3.4 Panel feedthroughs
3.4.2
Panel feedthrough N/SMA female/female
Panel feedthrough for wall thicknesses up to a maximum of 5.5 mm, two N-Connect/SMA
female connectors.
Technical specifications
Order number
6GK5 798-0PT00-2AA6
Electrical data
Standing wave ratio
(VSWR)
f [GHz]
1.0
2.0
2.4
VSWR
1.012
1.088
< 1.171
Dimensions and materials
Dimensions (length x width x height)
31.3 x 25.4 x 25.4 mm
Materials

Core material: CuBe2

Coating: Ni2Au1.27

Core material: CuZn39Pb3

Coating: CuSnZn3
Outer conductor SMA
end

Core material: CuZn39Pb3

Coating: Ni2Au0.8
Insulation

PTFE

Silicone-free
Inner conductor
Outer conductor N end
Inner seal
Silicone-free
Outer seal

NBR

Silicone-free
Permitted ambient conditions
Ambient temperature
-40°C ... +70 °C
Passive network components IWLAN
38
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.4 Panel feedthroughs
31,3
11
2
12,55
1/4-36 UNS 2A
25,4
18,25
Ø17,8
Ø22
5/8-24 UNEF 2A
Dimension drawing
3,2
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
39
Technical data
3.5 Attenuator N-Connect male/female
3.5
Attenuator N-Connect male/female
Technical specifications
Order number
6GK5 798-0AP00-4CA0
Electrical data
Frequency range
≤ 6 GHz
Impedance
50 Ω
Insert attenuation
10 dB
Power range
1W
Dimensions, materials and weight
Number of plug-in connections
2
Dimensions (length x diameter)
45.7 x 21 mm
Materials

Core material: CuBe2

Coating: Cu1Ni2Au0.8

Core material: CuZn39Pb3

Coating: CuSnZn3
Inner conductor
Metallic parts
Insulation
PTFE
Seal
Silicone-free
Weight
-
Degree of protection
-
Permitted ambient conditions
Ambient temperature
During operation
-40 °C ... +70 °C
During storage
-40 °C ... +70 °C
During transportation
-40 °C ... +70 °C
Passive network components IWLAN
40
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.5 Attenuator N-Connect male/female
Dimension drawing
5/8-24 UNEF
Ø21
SW 20
45.7
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
41
Technical data
3.6 Power splitter N-Connect female
3.6
Power splitter N-Connect female
Double power splitter, Y element for splitting RCoax cables.
Technical specifications
Order number
6GK5 798-0SN00-0EA0
Electrical data
Frequency range
2.4 to 6 GHz
Impedance
50 Ω
Return loss
≥ 24 dB
Insert attenuation
≤ 3.05 dB
Power range
250 W
Dimensions, materials and weight
Number of plug-in connections
3
Dimensions (length x width x depth)
131.4 x 71.4 x 34 mm
Materials

Core material: Beryllium copper

Coating: Silver

Core material: Brass

Coating: Optargen
Inner conductor
Outer conductor
Housing
Brass
Dielectric
PTFE
Seal
NBR
Weight
937 g
Degree of protection
IP67
Permitted ambient conditions
Ambient temperature
During operation
-25 °C … +110 °C
During storage
-25 °C … +110 °C
During transportation
-25 °C … +110 °C
Passive network components IWLAN
42
System Manual, 11/2012, C79000-8976-C282-01
Technical data
3.6 Power splitter N-Connect female
Dimension drawing
131.4
17.2
37
Ø26
100
18.7
(71.4)
18.7
34
18.7
5/8-24 UNEF
5/8-24 UNEF
5/8-24 UNEF
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
43
Technical data
3.7 HF coupler N-Connect male/male
3.7
HF coupler N-Connect male/male
Technical specifications
Order number
6GK5 798-0CP00-1AA0
Electrical data
Frequency range
6 GHz
Power range
1W
Return loss
≥ 0.1 dB
Standing wave ratio
(VSWR)
f [GHz]
1.0
2.4
VSWR
1.012
< 1.048
Construction and dimensions
Dimensions (length x diameter)
36.4 x ∅20.8 mm
Materials

Core material: CuZn39Pb3

Coating: Ag5

Core material: CuZn39Pb3

Coating: CuSnZn3

Core material: CuZn39Pb3

Coating: CuSnZn3
Inner conductor
Outer conductor
Metallic parts
Insulation
PTFE
Seal

MVQ

Silicone-free
Permitted ambient conditions
Ambient temperature
-40 ... +70 °C
Dimension drawing
5/8-24 UNEF
Ø20.8
36.4
Passive network components IWLAN
44
System Manual, 11/2012, C79000-8976-C282-01
Index
M
A
Antennas
Directional antenna, 13
Directional antenna with dual horizontal/vertical
polarization, 13
Dual directional antenna with linear polarization, 13
Dual-band directional antenna with linear
polarization, 13
Helical antenna, 13
MIMO antenna, 13
Omnidirectional antenna, 13
Attenuator, 9, 11
Mobile Panel 277 IWLAN, 18
P
Panel feedthroughs, 9, 11, 12
Power splitter, 10, 11
R
RCoax cables, 14
S
C
Certification, 5
SCALANCE W74x, 17
SCALANCE W78x, 15
SCALANCE W7xx, 15
SIMATIC NET glossary, 6
E
ET 200pro IWLAN, 18
T
Terminating resistors, 8, 11, 12
F
Flexible connecting cables, 7, 11, 19
G
Glossary, 6
H
HF coupler, 10
I
IWLAN/PB Link PN IO, 18
L
Lightning protectors, 9, 11, 12
Passive network components IWLAN
System Manual, 11/2012, C79000-8976-C282-01
45
Index
Passive network components IWLAN
46
System Manual, 11/2012, C79000-8976-C282-01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement