Mk10E Smart Three Phase Electronic Revenue Meter
Mk10E
Smart Three Phase
Electronic Revenue Meter
Atlas Series - Class 0.5S and Class 1
PRODUCT INFORMATION
Built on the advanced Atlas metering platform, the
Mk10E has a Class 0.5S measurement engine with
many enhancements including smart grid solutions,
high data storage, data processing, UPS configuration
and enhanced communications capabilities.
KEY FEATURES
UPS
AMI READY
HIGH
ACCURACY
CT \ WC
CONNECTED
MULTIPLE
COMMS OPTIONS
MEASURE
EVERYTHING
UPGRADEABLE
ANTI
TAMPER
UNINTERRUPTIBLE
POWER SUPPLY
Mk10E
Smart Three Phase
Electronic Revenue Meter
Atlas Series - Class 0.5S and Class 1
SPECIFICATIONS
Measurement
Battery
Load Survey/Profile
Security
• Class 0.5S and Class 1
• Internal battery
• NMI M6 compliant
• Option for external for backup
• Over 5000 days storage (2 channels,
30-minute intervals)
• Multi-level security (username and
password including encrypted log-in)
• Compliance with IEC 62052-11,
• Option for UPS battery
• Option for additional Supercap
62053-21, *62052-31, 62053-22,
(72 hours)
62053-23, *62053-24
• Compliance with AS 62052.11,
62053.21, 62053.22, 62053.23
• Backup time of 10 years without power
(Lithium Battery)
• 3 phase 3 wire
Data Memory
• 3 phase 4 wire
• Option for neutral current
measurement
• Withstand: Up to 290V
• Burden: IEC 62053-61 compliant
• 57.7V - 240V Auxiliary Supply
• Battery UPS
Current
• CT range: 1/4A, 1/10A, 5/6A,
- RS-232 with modem power supply
• Ability to store average/minimum/
maximum values for interval duration
- RS-485 multi-drop (2 or 4-wire
5/10A, 5/20A
Time of Use
• Up to 32 separate import and export
registers
• Compatible with MV-90™
• Definable enunciators
• Daily, weekly, monthly, yearly and
special days
• Display available without main power
• Up to 200 programmable special days
• LED Backlight Option
• Up to 61 previous billing periods plus
billing totals
• Block or rolling maximum demand
Measured Values
Calendar
Frequency
• 3 element 4 quadrant
• Supports Daylight Saving time
• 45Hz - 65Hz
• Import/Export/Absolute Wh, varh and
VAh
• Supports Gregorian or Persian
calendars
Inputs/Outputs Configuration
• Fundamental Wh
• Up to 4 independently isolated I/O
• Per quadrant Wh, varh and VAh
• Phase A, B, C and Total
• W, var, VA, Vrms, Irms
• Power factor, frequency, phasor angles
• Supports ripple control/AFLC
5V, 12V, 48V, 110V, 240V
Power Quality Indication
• Active input voltage:
12V (common ground)
• Total Harmonic Distortion (THD)
• Energy, pulsing inputs
• EDMI EziView software available for
meter programming and reading
(Windows® compatible)
• EDMI MultiDrive software available for
large scale AMI and AMR Solutions
(Windows® compatible)
• Supported by many popular
third-party multi-vendor AMR systems
Environmental
• Operating range limit:
• Bypassing current and reverse
current detection
• Advanced tamper detection and
logging
• Pre-programmed alarms for meter
self-check
• Option for live waveform display
• Alarms trigger LEDs, enunciators, relay
outputs or communications event
Sag/Swell
• Alarms are stored in event logs
• Relay output: 240V, 2A
• 5 Cycle resolution
• Option for fixed-threshold magnetic
• 2 Programmable LED indicators
• Records time/date/phase/duration/
average and worst excursion
• *Option for high-sensitivity 3D
• Programmable trigger levels
Software
• Specified operating range:
• BOSFET output:
1ms to 100ms
• Supports Function Based Setup
• Provision for sealing with conventional
wire or plastic seals
• Unbalance (Sequence Components)
• Programmable output pulse width:
• Supports EDMI command line, DLMS
and MODBUS protocols
Tamper Detection and Alarms
• S0 Output: 27V, 27mA maximum
240V, 100mA maximum
RJ45 or 2-wire screw terminal)
size
• Burden: <0.5VA/phase
• Passive input voltage:
(2G/3G/4G LTE supported)
• UDP/IP GPRS/PPP capable
• Time of maximum demand
• Options include: Passive/Active Inputs,
S0/BOSFET/Relay outputs
or ANSI Type 2 (ANSI C12.18)
• Up to 8 rates plus unified rate
• Accuracy (internal) within 15 seconds
per month at 23˚C
• WC range: 5/100A, 10/100A
- Optical port: FLAG (IEC 62056-21)
display with 10.5mm x 5.1mm digit
Real-time Clock
• CT limit: 20 x Imax for 0.5 seconds
communication ports:
LCD Display
• Up to 60 user-defined screens of any
meter parameter
Auxiliary Supply Options
• Up to 3 independently working
• Energy, instantaneous readings,
pulsing inputs as channel sources
• *Large 14 segment alphanumeric
• Operating range: 52V – 290V
independent surveys
Communications
• 2 MB of non-volatile memory
with 10.7mm x 6.67mm digit size
• Nominal voltage: 57.7V – 240V
• Up to 32 channels and 4
• Intervals programmable from 1 to 60
minutes
• Large 7 segment alphanumeric display
Voltage
• Supports Advanced Demand • Up to 7 independent security levels
Management (ADM) with prioritised • Up to 6 individual users
rules
• AES128 bit encryption
• AMI Ready
tamper detection
-25˚C to +60˚C
-40˚C to +70˚C
• Storage range limit:
-40˚C to +80˚C
• Relative humidity: Up to 95%
non-condensing for 30 days
• Ingress protection: IP54
• Protective Class II
• Surge Test: 5kV
• Impulse Test: 10kV
Dimensions and Weight
magnetic tamper detection with
• Dimensions: Standard version: 262mm
(L) x 175mm (W) x 95mm (D)
configurable threshold
• Dimensions: Extended version:
• Source impedance monitoring
290mm (L) x 175mm (W) x 95mm (D)
• Weight: 2.0 kg
Specifications with * symbol available in manufacturing codes with prefix 1Ex3
EDMI Limited
47 Yishun Industrial Park A, Singapore 768724
Tel: +65 6756 2938 | Fax: +65 6756 0125
Email: [email protected] | [email protected]
www.edmi-meters.com
Copyright © 2017 EDMI Limited. All Rights Reserved. All trademarks are the property of their respective holders. EDMI’s Policy is one of continuous product development and the right is reserved to modify specifications contained herein without notice.
MKT-BR-007 Rev 01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement