SKF Microlog Accessories Catalog

SKF Microlog Accessories Catalog
SKF Microlog
Accessories Catalog
Foreword
The SKF brand now stands for more
than ever before, and means more
to you as a valued customer.
While SKF maintains its leadership
as the hallmark of quality bearings
throughout the world, new dimensions
in technical advances, product support
and services have evolved SKF into
a truly solutions-oriented supplier,
creating greater value for customers.
These solutions encompass ways to
bring greater productivity to customers,
not only with breakthrough applicationspecific products, but also through
leading-edge design simulation tools
and consultancy services, plant asset
efficiency maintenance programmes,
and the industry’s most advanced
supply management techniques.
The SKF brand still stands for the very
best in rolling bearings, but it now
stands for much more.
SKF – the knowledge engineering
company
2
Unmatched versatility, reliability and functionality have made the SKF Microlog Analyzer series of data collectors the premier
choice for portable, handheld condition
monitoring units.
Designed to help users establish or
upgrade an existing condition monitoring
program, SKF Microlog Analyzers handle the
tasks required to perform predictive maintenance on rotating machinery in countless
industries.
Data capture from a range of sources
SKF Microlog Analyzers automatically collect
both dynamic (vibration) and static (process)
measurements from almost any source,
including handheld and magnetically
mounted accelerometers, permanently
mounted vibration sensors or on-line monitoring systems. Temperature measurements
can be collected with a non-contact infrared
sensor or with a contact probe.
State-of-the-art operating technology
With robust, high-speed data processors
and optimum data storage capacity, SKF
Microlog Analyzers are equipped to operate
within today's most advanced computerized
maintenance management systems. Units
can be purchased with a range of individual
modules and accessories for specific types of
analysis, required to meet their plant's
monitoring needs.
Product compatibility
SKF Microlog models
Every product listed in this catalog contains a legend that shows
which SKF Microlog models are compatible with that product. An
example of the legend is shown below. For example, a product that
contains the legend below would be compatible with SKF Microlog
models CMXA 80 and CMXA 48.
The accessories in this catalog are applicable to the following
SKF Microlog models:
• •
Compatible
SKF Microlog
models
CMXA 80
CMXA 48
•
•
•
•
•
•
CMXA 80: SKF Microlog Analyzer AX series
CMXA 48: SKF Microlog Consultant
CMXA 75: SKF Microlog Analyzer GX series
CMXA 70: SKF Microlog Analyzer GX series
CMXA 44: SKF Microlog Analyzer MX series
CMXA 70-Z2: SKF Microlog Analyzer GX series, certified for use in
ATEX Zone 2 hazardous areas
• CMXA 45: SKF Microlog Advisor Pro
• CMXA 51-IS: SKF Microlog Analyzer, ATEX and IECEx certified
CMXA 75
CMXA 70 / 44
Accessories for discontinued SKF Microlog
models
CMXA 70-Z2
CMXA 45
For a list of accessories available for discontinued SKF Microlog
models, please refer to page 78.
CMXA 51-IS
Example of
compatibility legend
3
4
Contents
Accelerometers
7
Cables
23
Hardware
41
Power
61
Miscellaneous Accessories
67
5
6
Accelerometers
Triax accelerometer kit, CMAC 4370-K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
Small footprint accelerometer with integral cable, CMSS 2111 . . . . . . . . . . . . . . . . .
10
High frequency accelerometer kit, CMSS 2114-K . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
General purpose, low profile, side exit industrial accelerometer, CMSS 2200 and
CMSS 2200-M8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
Intrinsically safe (IS) industrial accelerometer, CMSS 2210 . . . . . . . . . . . . . . . . . . . .
15
Small diameter accelerometer, CMSS 732A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
CSA approved, general purpose industrial accelerometer, CMSS 793-CA . . . . . . . . .
18
ATEX approved, intrinsically safe (IS), general purpose industrial accelerometer,
CMSS 793-EE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
Medium duty magnetic base, CMSS 908-MD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
7
CMAC 4370-K
• • • •
Triax accelerometer kit
SKF’s triax accelerometer quickly and automatically measures horizontal, vertical and
axial (triaxial) data with the press of a button. Triaxial measurements offer the user
additional information on the condition of
machinery, enabling a more complete diagnostic analysis. For example, measuring in a
vertical direction often provides insight into
how the shaft is restrained when considering bearing looseness. A horizontal orientation is preferred for bearing fault diagnosis and an axial measurement can provide clues as to the severity of shaft misalignment.
The SKF Microlog can acquire data simultaneously from all three
axes. The triax accelerometer also enables measurement in any of
the three axes where, in specialized cases, a single point accelerometer would be unable to measure data due to physical mounting
restrictions or a difficult to access mounting surface.
For those who typically collect triaxial data, the sensor dramatically reduces data collection time. For users who up until now have
collected only one data point per sensor location, triax offers the
advantage of additional information for improved diagnostics. The
triax accelerometer facilitates the efficient collection of accurate and
repeatable machine date for enhanced decision making.
Dynamic
•
•
•
•
•
•
•
•
•
Sensitivity (±5%): 100 mVg
Range full scale: 50 g, RMS
Resolution (electrical noise): 0,0005 g, RMS
Frequency response:
– ±5%: 0,5 to 3 000 Hz
– ±10%: 0,3 to 5 000 Hz
– ±3 dB: 0,2 to 10 000 Hz
Discharge time constant: 0,6 s
Mounted resonant frequency, nominal: 25 kHz
Amplitude non-linearity: ±1% full scale maximum
Transverse sensitivity maximum: 5%
Strain sensitivity: 0,001 g per microstrain at 250/μ Ω
Electrical
•
•
•
•
•
Bias voltage range: 12 to 13 V DC
Supply voltage range*: 18 to 30 V DC
Supply current range: 2 to 20 mA
Output impedance, nominal: 100 Ω
Case ground isolation, signal / power ground pin to case: 10 MΩ
* Do not apply power to this instrument without current limiting in the range
of 20 mA maximum. To do so will immediately destroy the integral amplifier. It is suggested that only SKF approved power units be utilized for
powering this instrument.
8
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
Specifications for triax accelerometer
CMXA 80
CMXA 45
CMXA 51-IS
Environmental
•
•
•
•
•
Maximum vibration: 1 000 g, RMS
Maximum shock: 2 000 g peak
Temperature range: –54 to +121 °C (–65 to +250 °F)
Thermal coefficient of sensitivity: 0,03%/°F
Environmental seal: Welded / glass to metal seal / O-rings,
hermetic
Physical
• Weight: 115 g (4 oz.)
• Size (not including connector): 41 × 41 × 24 mm
(1.625 × 1.625 × 0.950 in.)
• Mounting provision: Captive 1/4–28 mounting screw
• Connector, coaxial, radically mounted: Four pin MIL-C-26482,
8-4P
• Case material: Aluminum alloy
• Recommended magnetic base: CMSS 908-MD
Kit contents
Optional accessories
• Triax accelerometer
• Anti-rotation pin mounted on the bottom surface of the sensor
(the anti-rotation pin can be carefully un-threaded from the sensor so that it can be permanently mounted)
• CMAC 5009: Triaxial accelerometer cable
• CMAC 4300: Stud adapter
• CMSS 2620-3: Studs (three)
• Calibration certificate traceable to NIST
CMAC 9600-10 Toolkit for 1/4–28 stud
Dimension diagram
<^ST[%$!# #!'D=5\^d]cX]VbRaTf
<^d]cX]VbRaTfXbSTcPRWPQ[T
;^RPcX^]^Uß '"
P]cXa^cPcX^]_X]
eXTfTSUa^\PQ^eT
"\\
# X]
"
!
"!\\ (X]
Triax accelerometer
4C
4A
0gXb!
"!cP__TSW^[TU^a
RP[XQaPcX^]ch_XRP[cf^_[PRTb
4;
22
0
0;
G8
80
CA
B=
"&"<%
4A
><
# "\\
%!$X]
2^\\^]Va^d]S
?X]3
$"'\\! !X]
"
0gXb
BXV?fa0gXb
?X]0
BXV?fa0gXb"
?X]2
BXV?fa0gXb!
?X]1
0]cXa^cPcX^]_X]XbP##b^RZTcWTPSRP_
bRaTfWTPSSXP\TcTa#%$\\ '"X]
\PgX\d\
BXV?faVa^d]SaTcda]XbXb^[PcTSUa^\RPbT
Qh- <è
"
!
<^ST[%$$ UXQTa
fPbWTa
0gXb"
!# \\
($X]
C^a`dT\^d]cX]VbRaTfC $[QX]
0gXbPaa^fWTPSbST[X]TPcTbT]bTP]S
SXaTRcX^]^U_^bXcXeTPRRT[TaPcX^]U^a
_^bXcXeTV^X]Ve^[cPVT
CMAC 5009 Triaxial accelerometer cable
!$#\\
X]
<^d]cX]VbdaUPRT
Ordering information
CMAC 4370-K Triax accelerometer kit. Each kit includes a triax accelerometer, triax accelerometer cable, stud adapter and three studs. A calibration certificate traceable to NIST is also supplied with each instrument.
CMAC 4300 Stud
adapter
CMSS 2620-3 Stud
Optional Accessories
• CMAC 9600-10 Toolkit for 1/4–28 stud
• CMSS 908-MD Medium duty magnetic base
9
CMSS 2111
• • • •
Small footprint accelerometer with integral
cable
The CMSS 2111 is a small footprint accelerometer that includes an
integrated 2 m (6.56 ft.) cable along with a magnetic mount.
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
Specifications
•
CMXA 45
Dynamic
•
•
•
•
•
•
•
CMXA 51-IS
Sensitivity (±10%): 100 mVg
Measurement range: ±50 g
Frequency range (±3 dB): 0,5 to 10 000 Hz
Resonant frequency: 22 kHz
Broadband resolution (1 to 10 000 Hz): 350 μg
Non-linearity: ±1%
Transverse sensitivity: ≤7%
Electrical
•
•
•
•
•
•
•
Settling time (within 1% of bias): ≤2,0 s
Discharge time constant: ≤0,3 s
Excitation voltage: 18 to 28 V DC
Constant current excitation: 2 to 20 mA
Output impedance: <150 Ω
Output bias voltage: 8 to 12 V DC
Spectral noise:
– 10 Hz: 8 μg/√Hz
– 100 Hz: 5 μg/√Hz
– 1 kHz: 4 μg/√Hz
Environmental
• Overload limit (shock): 5 000 g peak
• Temperature range (operating): –54 to +121 °C (–65 to +250 °F)
• Enclosure rating: IP 68
Physical
•
•
•
•
•
•
•
•
•
•
•
•
Size (hex × height): 14 × 64 mm (0.55 × 2.52 in.)
Weight (with cable): 99,3 g (3.5 oz.)
Cable length: 2 m (6.56 ft.)
Mounting: Magnet
Sensing element: Ceramic
Sensing geometry: Shear
Housing material: Stainless steel
Sealing: Molded
Electrical connector: Molded integral cable
Electrical connection position: Top
Cable type: Polyurethane
Connector: Fischer type 103 six pin
Ordering information
CMSS 2111 Small footprint accelerometer with an integrated cable and
a magnetic mount.
10
CMSS 2114-K
• • • •
High frequency accelerometer kit
The CMSS 2114-K is a high frequency accelerometer kit that
includes a high frequency cable with an adhesive mounting base.
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
Specifications
•
CMXA 45
Dynamic
•
•
•
•
•
•
•
Electrical
•
•
•
•
•
•
CMXA 51-IS
Sensitivity (±15%): 10 mVg
Measurement range: ±500 g peak
Frequency range (±3 dB): 5 to 60 000 Hz
Resonant frequency: ≥95 kHz
Broadband resolution (1 to 10 000 Hz): 0,002 g RMS
Non-linearity: ≤1%
Transverse sensitivity: ≤5%
352A60 High frequency ICP accelerometer
Excitation voltage: 18 to 30 V DC
Constant current excitation: 2 to 20 mA
Output impedance: ≤100 Ω
Output bias voltage: 8 to 12 V DC
Discharge time constant: 0.02 to 0.06 s
Spectral noise:
– 10 Hz: 160 μg/√Hz
– 100 Hz: 40 μg/√Hz
– 1 kHz: 15 μg/√Hz
– 10 kHz: 10 μg/√Hz
Environmental
• Overload limit (shock): ±5 000 g peak
• Temperature range: –54 to +121 °C (–65 to +250 °F)
• Base strain sensitivity: ≤0,05 g μ
Physical
•
•
•
•
•
•
•
•
•
•
Size (hex × height): 10,7 × 20,6 mm (0.42 × 0.81 in.)
Weight: 6,0 g (0.21 oz.)
Sensing element: Ceramic
Sensing geometry: Shear
Housing material: Stainless steel
Sealing: Welded hermetic
Electrical connector: 5-44 Coaxial
Electrical connection position: Top
Mounting thread: 10-32, male
Mounting torque: 113 to 225 Ncm (10 to 20 in. lbs.)
CMAC 5062 High frequency accelerometer cable
Note: All specifications are at room temperature unless otherwise specified.
Adhesive mounting
base
11
Kit contents
• 352A60: High frequency ICP accelerometer
• CMAC 5062: High frequency accelerometer cable, Fischer six pin
to Microdot connector
• Adhesive mounting base
Note: Loctite 454 insensitive adhesive gel is the recommended adhesive.
This item is not included in the kit.
Dimension diagram
!'\\
!%\\
' X]
X]
$##R^PgXP[R^]]TRc^a
<>34;"$!0%
B=B
#%\\ 'X]
""\\
"X]
"!
\^d]cX]VW^[T
!
($\\
"&$X]
!
BcdSaT\^eTSU^abT]b^afXcW
PSWTbXeT\^d]c^_cX^]
<%¾&$%VcWaTPSU^a
\TcaXR^_cX^]
&\\
#!X]
Ordering information
CMSS 2114-K High frequency accelerometer kit, which includes a high
frequency ICP accelerometer, cable and adhesive mounting base.
12
CMSS 2200 / CMSS 2200-M8
• • • •
General purpose, low profile, side exit
industrial accelerometer
The CMSS 2200 and CMSS 2200-M8
industrial accelerometers, with their side
exit and two pin connector, offer a low profile for machinery with limited clearance.
The sensor mounts in any orientation.
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
Features
CMXA 45
CMXA 51-IS
• Rugged, economical and all around
general purpose sensor
• Sensitivity, 100 mVg to optimize use in
multiple applications
• Exceptional bias voltage (BV) stability at elevated temperatures
• Designed for exceptional low noise level for low frequencies at
elevated temperatures
• Meets stringent CE, EMC requirements
• Low profile with captive mounting bolts (1/4–28, M6 × 1,00 or
M8 × 1,25) provided
• Corrosion resistant and hermetically sealed
• Reverse polarity wiring protection
Specifications
Dynamic
•
•
•
•
•
Sensitivity: 100 mVg
Sensitivity precision: ±10% at 25 °C (77 °F)
Acceleration range: 80 g peak
Amplitude linearity: 1%
Frequency range:
– ±10%: 1,0 to 5 000 Hz
– ±3 dB: 0,7 to 10 000 Hz
• Resonance frequency: Mounted, minimum 22 kHz
• Transverse sensitivity: ≤5% of axial
Electrical
• Power requirements:
– Voltage source: 18 to 30 V DC
– Constant current diode: 2 to 10 mA DC, recommended 4 mA
• Electrical noise: 2,0 Hz; 20 μg/√Hz
• Output impedance: <100 Ω
• Bias output voltage: 12 V DC
• Grounding: Case isolated, internal shielding
Environmental
• Temperature range: –50 to +120 °C (–58 to +248 °F), operating
temperature
• Vibration limits: 500 g peak
• Shock limit: 5 000 g peak
• Electromagnetic sensitivity, equivalent g, maximum: 70 μg/gauss
• Sealing: Hermetic
• Base strain sensitivity: 200 μg/microstrain
• CE: According to the generic immunity standard for Industrial
Environment EN50082-2
• Acceptance criteria: The generated “false equivalent g level” under
the above test conditions should be less than 2 mg peak to peak
13
Physical
•
•
•
•
•
•
•
•
•
Dimensions: 53 × 25 × 40 mm (2.1 × 1.0 × 1.6 in.)
Weight: 145 g (5.1 oz.)
Case material: 316L stainless steel
Mounting: See ordering information
Mounting torque: 3,4 Nm (30 in. lbs.)
Pin A connector: Signal / Power
Pin B connector: Common
Mating connector: CMSS 3106F-10SL-4S or equivalent
Recommended cable: Two conductor shielded, Teflon jacket,
100 pF/m (30 pF/ft.) – CMAC 5209, CMAC 5209-06S or
CMAC 5209-10
• Recommended magnetic base: CMSS 908-MD
Note: Specifications conform to ISA-RP-37.2 (1 to 64) and are typical values
referenced at 24 °C (75 °F), 24 V DC supply, 4 mA constant current and
100 Hz.
Note: This accelerometer is not recommended for use in hazardous
environments.
Dimension diagram
#X]b^RZTcWTPS
RP_cXeTbRaTf
#\\ !%\\
%X] #X]
<>34;2<BB!!
<>34;2<BB!!<'
B=B
%"\\
!$X]
!"\\
(!X]
2<BB!!)
#!'\^d]cX]VcWaTPS
2<BB!!<')
<'\^d]cX]VcWaTPS
!$\\
X]
"&\\
##X]
$"\\
! X]
!_X]R^]]TRc^a
<8;2$ $
Ordering information
CMSS 2200 General purpose, low profile, side exit industrial accelerometer with MIL-C-5015 two pin connector. 1/4–28 and M6 mounting
studs provided. Calibration sensitivity and nominal sensitivity are provided for each accelerometer package.
CMSS 2200-M8 General purpose, low profile, side exit industrial accelerometer with MIL-C-5015 two pin connector. M8 mounting studs provided. Calibration sensitivity and nominal sensitivity are provided for
each accelerometer package.
Optional accessories
• CMSS 908-MD Medium duty magnetic base
14
CMSS 2210
CMXA 80
Intrinsically safe (IS) industrial accelerometer
CMXA 48
CMXA 75
The CMSS 2210 industrial accelerometer is intrinsically safe and is
ATEX and IECEx Group I and II approved.
CMXA 70 / 44
•
Specifications
CMXA 70-Z2
CMXA 45
Dynamic
•
•
•
•
•
•
Standard sensitivity: 100 mVg ±10% nominal at 80 Hz
Frequency response: 2 Hz to 10 kHz ±5% (–3 dB at 0,8 Hz)
Mounted base resonance: 18 kHz, nominal
Isolation: Base isolated
Transverse sensitivity: <5%
CMXA 51-IS
Electrical
• Electrical noise: 0,1 mg maximum
• Current range: 0,5 to 8 mA
• Bias voltage: 12 V DC, nominal
Dimension diagram
!_X]R^]]TRc^a
<8;2$ $
Environmental
• Temperature range:
– T4: –55 °C ≤ Ta ≤ +115 °C (–67 °F ≤ Ta ≤ +239 °F)
– T6: –55 °C ≤ Ta ≤ +65 °C (–67 °F ≤ Ta ≤ +149 °F)
Physical
•
•
•
•
•
•
•
Dimensions: 51 × 25 mm (2.0 × 1.0 in.)
Weight: 100 g (3.5 oz.), nominal
Sealing: IP 67
Mounting torque: 8 Nm
Case material: Stainless steel
Recommended cable: CMAC 5115
Recommended magnetic base: CMSS 908-MD
$ \\
!X] <>34;2<BB!! B=B
!!!\\
'&X]
Certifications
• Group I:
– Baseefa02ATEX0245X and IECEx BAS 08.0013X
– Ex I M1 Ex ia I: –55 °C ≤ Ta ≤ +115 °C (–67 °F ≤ Ta ≤ +239 °F)
• Group II*:
– BAS02ATEX1057X and IECEx BAS 08.0013X
– Ex II 1GD T135 °C (275 °F) Ex ia IIC T4
– Ex iaD 20 T135 °C (275 °F): –55 °C ≤ Ta ≤ +115 °C
(–67 °F ≤ Ta ≤ +239 °F)
– Ex II 1GD T85 °C (185 °F) Ex ia IIC T6
– Ex iaD 20 T85 °C (185 °F): –55 °C ≤ Ta ≤ +65 °C
(–67 °F ≤ Ta ≤ +149 °F)
• 500 V isolation: Units will pass a 500 V isolation test
• Barrier: 1 × MTL7728+ (BAS01ATEX7217) or
(P&F Z728 BAS01ATEX7005) or any other barrier that conforms
to note 5 of ATX027
* Warning: The Ci and Li were previously lower. The installer must take
account of the increase in internal capacitance and inductance present on
this apparatus.
#!'
\^d]cX]VW^[T
!$\\
X]
!!!\\
'&X]
!$\\
X]
Ordering information
CMSS 2210 Intrinsically safe (IS) industrial accelerometer.
Optional accessories
• CMSS 908-MD Medium duty magnetic base
15
CMSS 732A
• • • •
Small diameter accelerometer
The CMSS 732A is an accelerometer with a 10 × 32 mounting stud.
Features
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
Wide dynamic range
Compact construction to fit in tight spaces
Wide frequency range
Small size, lightweight
Hermetic seal
Designed for stud mounting
Optional magnetic base mounting
•
•
•
•
•
•
•
•
CMXA 80
CMXA 45
CMXA 51-IS
Specifications
Dynamic
•
•
•
•
Sensitivity, ±5%, 25 °C (77 °F): 10 mVg
Acceleration range: 500 g peak
Amplitude non–linearity: 1%
Frequency response:
– ±5%: 2,0 to 15 000 Hz
– ±3 dB: 0,5 to 25 000 Hz
• Resonance frequency: 60 kHz
• Transverse sensitivity, maximum: 7% of axial
• Temperature response:
– –50 °C (–58 °F): –10%
– +120 °C (+248 °F): +5%
Environmental
•
•
•
•
•
Temperature range: –50 to +120 °C (–58 to +248 °F)
Vibration limit: 500 g peak
Shock limit: 5 000 g peak
Electromagnetic sensitivity, equivalent g: 100 μg/gauss
Base strain sensitivity: 0,005 g/μ strain
Connections
Electrical
• Power requirements:
– Voltage source: 18 to 30 V DC
– Current regulating diode: 2 to 10 mA
• Electrical noise, equivalent g:
– Broadband, 2,5 Hz to 25 kHz: 200 μg
– Spectral:
· 10 Hz: 20 μg/√Hz
· 100 Hz: 3 μg/√Hz
· 1 000 Hz: 2 μg/√Hz
· 10 000 Hz: 2 μg/√Hz
• Output impedance, maximum: 100 Ω
• Bias output voltage: 10 V DC
• Grounding: Case grounded
16
• Shell: Common
• Pin A: Power / signal
Physical
•
•
•
•
•
•
•
•
Dimension diagram
Dimensions: 23,62 × 12,45 mm (0.93 × 0.49 in.)
Weight: 13 g (0.46 oz.)
Material: 316L stainless steel
Mounting: 10 × 32 tapped hole
Output connector: 10 × 32 coaxial
Mating connector: R1
Recommended cable: CMAC 5061
Recommended mounting base: CMSS B13
! (\\
#'X]
<>34;2<BB&"!
!"%!\\
("X]
B=B
!X]
WTg
"!R^PgXP[
R^]]TRc^a
Optional accessories
!#$\\
#(X]
"!
\^d]cX]VW^[T
CMSS B13 Magnetic base mounting
Ordering information
CMSS 732A Small diameter, high frequency accelerometer.
A 10 × 32 mounting stud is provided. Calibration sensitivity is provided
on each accelerometer package with nominal sensitivity etched on each
unit.
Optional accessories
• CMSS B13 Magnetic base mounting
• CMAC 5061 High frequency accelerometer cable
17
CMSS 793-CA
• • • •
CSA approved, general purpose industrial
accelerometer
The CMSS 793-CA is an industrial standard acceleration sensor with
a top exit C5015 two pin connector and agency approvals.
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
Features
•
•
•
•
•
Class I, Division 1 certification
Ground isolated
Rugged construction
Corrosion resistant and hermetically sealed for installation in high
humidity areas
• ESD protection
• Reverse wiring protection
CMXA 45
CMXA 51-IS
Specifications
Dynamic
•
•
•
•
Sensitivity, ±5%, 25 °C (77 °F): 100 mVg
Acceleration range: 80 g peak
Amplitude non-linearity: 1%
Frequency response:
– ±5%: 1,5 to 5 000 Hz
– ±10%: 1,0 to 7 000 Hz
– ±3 dB: 0,5 to 15 000 Hz
• Resonance frequency: 25 kHz
• Transverse sensitivity, maximum: 5% of axial
• Temperature response:
– –50 °C (–58 °F): –10%
– +120 °C (+248 °F): +5%
Electrical
• Power requirements:
– Voltage source: 18 to 30 V DC
– Current regulating diode: 2 to 10 mA
• Electrical noise, equivalent g:
– Broadband, 2,5 Hz to 25 kHz: 600 μg
– Spectral:
· 10 Hz: 8 μg/√Hz
· 100 Hz: 5 μg/√Hz
· 1 000 Hz: 5 μg/√Hz
• Output impedance, maximum: 100 Ω
• Bias output voltage: 12 V DC
• Grounding: Case isolated, internally shielded
18
Environmental
•
•
•
•
•
Temperature range: –50 to +120 °C (–58 to +248 °F)
Vibration limit: 500 g peak
Shock limit, minimum: 5 000 g peak
Sealing: Hermetic
Base strain sensitivity: 0,0005 g/μ strain
Connections
• Shell: Ground
• Pin A: Power / signal
• Pin B: Common
Agency approvals
• Canadian Standards Association (CSA)
– Class I, Division 1, Groups A, B, C, D
– Class II, Division 1, Groups E, F, G
– Class III, Division 1
Physical
Dimension diagram
•
•
•
•
•
•
•
•
Dimensions: 61,0 × 25,4 mm (2.42 × 1.00 in.)
Weight: 112 g (3.95 oz.)
Sensing element design: PZT ceramic / compression
Case material: 316L stainless steel
Mounting: 1/4–28 tapped hole
Output connector: MIL-C-5015 style two pin
Mating connector: R6 type
Recommended cable: CMAC 5209, CMAC 5209-06S or
CMAC 5209-10
• Recommended magnetic base: CMSS 908-MD
Cf^_X]R^]]TRc^a
<8;2$ $
$ %X]WTg
% \\
!#!X]
#$\\
&'X]
<>34;2<BB&("GG
B=B
#!'
\^d]cX]V
W^[T
!$#\\
X]
!$#\\
X]
!$#\\
X]
Ordering information
CMSS 793-CA CSA approved, general purpose industrial accelerometer.
1/4–28
mounting studs are provided. Calibration sensitivity is provided
on each accelerometer package with nominal sensitivity etched on each
unit.
Optional accessories
• CMSS 908-MD Medium duty magnetic base
19
CMSS 793-EE
ATEX approved, intrinsically safe (IS), general
purpose industrial accelerometer
CMXA 80
The CMSS 793-EE is an industrial standard acceleration sensor with
a top exit C5015 two pin connector and agency approvals.
CMXA 75
CMXA 48
CMXA 70 / 44
•
Features
•
•
•
•
Intrinsically safe certification
Ground isolated
Rugged construction
Corrosion resistant and hermetically sealed for installation in high
humidity areas
• ESD protection
• Reverse wiring protection
CMXA 70-Z2
CMXA 45
•
CMXA 51-IS
Specifications
Dynamic
•
•
•
•
Sensitivity, ±5%, 25 °C (77 °F): 100 mVg
Acceleration range: 80 g peak
Amplitude non-linearity: 1%
Frequency response:
– ±5%: 1,5 to 5 000 Hz
– ±10%: 1,0 to 7 000 Hz
– ±3 dB: 0,5 to 15 000 Hz
• Resonance frequency: 25 kHz
• Transverse sensitivity, maximum: 5% of axial
• Temperature response:
– –50 °C (–58 °F): –10%
– +120 °C (+248 °F): +5%
Electrical
• Power requirements:
– Voltage source: 18 to 30 V DC
– Current regulating diode: 2 to 10 mA
• Electrical noise, equivalent g:
– Broadband, 2,5 Hz to 25 kHz: 600 μg
– Spectral:
· 10 Hz: 8 μg/√Hz
· 100 Hz: 5 μg/√Hz
· 1 000 Hz: 5 μg/√Hz
• Output impedance, maximum: 100 Ω
• Bias output voltage: 12 V DC
• Grounding: Case isolated, internally shielded
20
Environmental
•
•
•
•
•
Temperature range: –50 to +120 °C (–58 to +248 °F)
Vibration limit: 500 g peak
Shock limit, minimum: 5 000 g peak
Sealing: Hermetic
Base strain sensitivity: 0,0005 g/μ strain
Connections
• Shell: Ground
• Pin A: Power / signal
• Pin B: Common
Agency approvals
• ATEX
– Intrinsically safe –50 to +120 °C (–58 to +248 °F) for:
· Class I, Zone 0, Ex ia IIC T4
· Class I, Zone 0, Aex ia IIC T4
· EEx ia IIC T4
Physical
•
•
•
•
•
•
•
•
•
Dimension diagram
Dimensions: 61,0 × 25,4 mm (2.42 × 1.00 in.)
Weight: 112 g (3.95 oz.)
Sensing element design: PZT ceramic / compression
Case material: 316L stainless steel
Mounting: 1/4–28 tapped hole
Output connector: MIL-C-5015 style two pin
Mating connector: R6 type
Recommended cable: CMAC 5115
Recommended magnetic base: CMSS 908-MD
Cf^_X]R^]]TRc^a
<8;2$ $
$ %X]WTg
% \\
!#!X]
#$\\
&'X]
<>34;2<BB&("GG
B=B
#!'
\^d]cX]V
W^[T
!$#\\
X]
!$#\\
X]
!$#\\
X]
Ordering information
CMSS 793-EE ATEX approved, intrinsically safe (IS), general purpose
industrial accelerometer.
1/4–28
mounting studs are provided. Calibration sensitivity is provided
on each accelerometer package with nominal sensitivity etched on
each unit.
Optional accessories
CMSS 908-MD Medium duty magnetic base
21
CMSS 908-MD
• • • • • • •
Medium duty magnetic base
The CMSS 908-MD is a multi-purpose magnetic base designed for
industrial vibration monitoring applications. The low profile magnet
has a 1/4–28 mounting hole to allow compatibility with SKF accelerometers and provides a solid mechanical connection to the machine.
Specifications
•
•
•
•
Diameter: 35 mm (1.4 in.)
Height: 19 mm (0.75 in.)
Pull strength: 23 kg (50 lbs.)
Mounting hole: 1/4–28
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
Accelerometer compatibility
The CMSS 908-MD medium duty magnetic base is compatible with
the following accelerometers:
• CMAC 4370: Triax accelerometer
• CMSS 2200 / CMSS 2200-M8: General purpose, low profile, side
exit industrial accelerometer
• CMSS 2210: Intrinsically safe (IS) industrial accelerometer
• CMSS 793-CA: CSA approved, general purpose industrial
accelerometer
• CMSS 793-EE: ATEX approved, intrinsically safe (IS), general
purpose industrial accelerometer
Dimension diagram
#!'\^d]cX]VW^[T
(\\
&$X]
"$\\ #X]
Ordering information
CMSS 908-MD Medium duty magnetic base.
22
Cables
Cable recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
Accelerometer cables
Triaxial accelerometer coiled cable, CMAC 5009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
High frequency accelerometer straight cable, CMAC 5061 . . . . . . . . . . . . . . . . . . . . .
26
High frequency accelerometer straight cable, CMAC 5062 . . . . . . . . . . . . . . . . . . . . .
27
Splitter, four channel straight cable, CMAC 5079 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
ATEX certified accelerometer coiled cable, CMAC 5115 . . . . . . . . . . . . . . . . . . . . . . .
28
Accelerometer coiled cable, 1,8 m (6 ft.), CMAC 5209 . . . . . . . . . . . . . . . . . . . . . . . .
28
Accelerometer coiled cable with safety breakaway, CMAC 5209-06S . . . . . . . . . . . .
29
Accelerometer coiled cable, 3 m (10 ft.), CMAC 5209-10 . . . . . . . . . . . . . . . . . . . . . .
29
Tachometer cables
BNC tachometer straight cable, CMAC 5211 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
Laser tachometer kit straight cable, 24 cm (9.5 in.), CMAC 5213 . . . . . . . . . . . . . . .
30
Laser tachometer kit straight cable, 2 m (6.56 ft.), CMAC 5214 . . . . . . . . . . . . . . . .
31
Extension cables
CHX signal input straight extension cable, 5 m (16.4 ft.), CMAC 5036. . . . . . . . . . . .
31
CHX signal input straight extension cable, 10 m (32.8 ft.), CMAC 5037 . . . . . . . . . .
32
Tachometer straight extension cable, 5 m (16.4 ft.), CMAC 5043 . . . . . . . . . . . . . . .
32
Tachometer straight extension cable, 10 m (32.8 ft.), CMAC 5044 . . . . . . . . . . . . . .
33
23
Miscellaneous cables
Cable converter, two pin MIL to BNC, CMAC 3715 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33
USB communication / power splitter straight cable, CMAC 5019 . . . . . . . . . . . . . . . .
34
Signal input straight cable, CMAC 5023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
Power / trigger splitter straight cable, CMAC 5032 . . . . . . . . . . . . . . . . . . . . . . . . . . .
35
Audio headphone straight cable, CMAC 5078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35
USB / A to B straight cable, CMAC 5082 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36
Temperature gun interface straight cable, CMAC 5087 . . . . . . . . . . . . . . . . . . . . . . .
36
Signal input straight cable, CMAC 5088 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
AC / DC signal coiled cable, CMAC 5116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
Trigger coiled cable, CMAC 5117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
Serial communication cable, CMAC 5201 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
Strobe light input straight cable, CMAC 5404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
Strobe light output straight cable, CMAC 5406 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
24
Cable recommendations
The following tables shows which cables are recommended for the accelerometers and hardware found in this catalog.
Cables recommended for accelerometers
CMSS 2210
CMSS 732A
Intrinsically safe (IS) industrial accelerometer
Small diameter accelerometer
CMSS 793-CA
CMSS 793-EE
CSA approved, general purpose industrial accelerometer
ATEX approved, IS, general purpose industrial accelerometer
•
•
•
CMAC 5209-10
•
CMSS 2200
General purpose, low profile, side exit industrial accelerometer
CMSS 2200-M8 General purpose, low profile, side exit industrial accelerometer
CMAC 5209-06S
•
CMAC 5209
Triax accelerometer kit
High frequency accelerometer kit
CMAC 5115
CMAC 4370-K
CMSS 2114-K
CMAC 5062
Accelerometer description
CMAC 5061
Accelerometer
model number
CMAC 5009
Cable model number
••
••
••
•
•
•
Cables recommended for hardware, etc.
CMAC 5090
CMAC 5403
Audio headset
CMSS 6155XK-U-CE Optical phase reference kit
CMSS 6165K-AX
CMSS 6195AX-K
Strobe light kit
Smart laser sensor tachometer
• •
•
• •
•
CMAC 5406
CMAC 5404
CMAC 5214
CMAC 5213
CMAC 5211
ICP microphone with integral
preamplifier kit
Universal power supply
CMAC 5088
CMAC 5084
CMAC 5087
Modal analysis hammer kit
Docking station
CMAC 5082
CMAC 5058
CMAC 5068
••
•
CMAC 5078
Modal analysis hammer kit
Modal analysis hammer kit
CMAC 5062
CMAC 5056
CMAC 5057
• •
CMAC 5061
Infrared thermometer
Laser tachometer kit
CMAC 5044
CMAC 4200-K-SL
CMAC 5030K
CMAC 5043
Product description
CMAC 5023
Hardware
model number
CMAC 5019
Cable model number
• •
••
•
•
•
•
•
• •
25
CMAC 5009
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 51-IS
Specifications
• Connectors: Fischer type 103 six pin CH1
I/P to a four pin socket
• Length: 1,8 m (6 ft.) coiled
The CMAC 5061 accelerometer cable is used
with the CMSS 732A accelerometer and
with the CMAC 5056 modal analysis hammer kit.
Specifications
• Connectors: Fischer type 103 six pin to a
Microdot connector
• Length: 3 m (10 ft.) straight
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
High frequency accelerometer
straight cable
• • • •
CMXA 80
CMXA 70-Z2
•
The CMAC 5009 coiled cable connects to the
SKF Microlog CH1 input connector at one
end and to a triaxial accelerometer at the
other end. The cable is recommended for
use with the CMAC 4370-K triax accelerometer kit.
• • • •
Triaxial accelerometer coiled
cable
CMAC 5061
CMXA 45
CMXA 51-IS
Ordering information
Ordering information
CMAC 5009 Triaxial accelerometer coiled cable.
CMAC 5061 High frequency accelerometer straight cable.
26
CMAC 5062
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
Specifications
CMXA 80
CMXA 45
Splitter, four channel straight
cable
The CMAC 5079 cable is used for connecting to either CH1 or CH2 on the CMXA 80
and CMXA 48. If connected to CH1, lead A
gives channel 1 and lead B gives channel 4.
If connected to CH2, lead A gives channel 2
and lead B gives channel 3.
CMXA 51-IS
• Connectors: Fischer type 103 six pin to a
Microdot
• Length: 3 m (10 ft.) straight
• •
The CMAC 5062 high frequency accelerometer cable is used with the 352A60 high frequency accelerometer in the CMSS 2114-K
kit and in the CMAC 5057 modal analysis
hammer kit.
• • • •
High frequency accelerometer
straight cable
CMAC 5079
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
Specifications
• Connectors: Two Fischer type 103 six pin
female sockets to one Fischer type 103
six pin male
• Length: 45 cm (1.5 ft.) straight
Note: Two cables are required to collect four channel measurements
Note: For CMXA 45 and CMXA 75, this cable can be used in CH2 only to
give three single axis simultaneous accelerometer inputs. A single accelerometer is connected to CH1 giving channel 1, then the cable into CH2 giving the same inputs as for CH2 of the CMXA 80.
Ordering information
Ordering information
CMAC 5062 High frequency accelerometer straight cable.
CMAC 5079 Splitter, four channel straight cable.
27
CMAC 5115
CMAC 5209
CMXA 80
The CMAC 5115 cable is ATEX certified and
is used to connect the accelerometer to the
signal connector.
CMXA 75
CMXA 48
CMXA 70 / 44
CMXA 70-Z2
Specifications
The CMAC 5209 coiled cable connects to the
CH1 or CH2 input connector at one end and
to an accelerometer at the other end. The
accelerometer connection is a two pin MIL
connector.
CMXA 45
•
• Connectors: Fischer type 102 four pin to
two pin MIL
• Length: 2 m (6.56 ft.) coiled
Accelerometer coiled cable,
1,8 m (6 ft.)
CMXA 51-IS
• • • • • •
ATEX certified accelerometer
coiled cable
Specifications
• Connectors: Fischer type 103 six pin to
two pin MIL
• Length: 1,8 m (6 ft.) coiled
Ordering information
Ordering information
CMAC 5115 ATEX certified accelerometer coiled cable.
CMAC 5209 Accelerometer coiled cable, 1,8 m (6 ft.).
28
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
CMAC 5209-06S
Specifications
• Connectors: Fischer type 103 six pin to
two pin MIL
• Length: 1,8 m (6 ft.) coiled
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
Accelerometer coiled cable,
3 m (10 ft.)
The CMAC 5209-10 coiled cable connects to
the CH1 or CH2 input connector at one end
and to an accelerometer at the other end.
CMXA 70-Z2
CMXA 45
CMXA 51-IS
Specifications
• • • • • •
The CMAC 5209-06S coiled accelerometer
cable is similar to the CMAC 5209 cable, but
also includes a safety breakaway.
• • • • • •
Accelerometer coiled cable
with safety breakaway
CMAC 5209-10
• Connectors: Fischer type 103 six pin to
two pin MIL
• Length: 3 m (10 ft.) coiled
Ordering information
Ordering information
CMAC 5209-06S Accelerometer coiled cable with safety breakaway.
CMAC 5209-10 Accelerometer coiled cable, 3 m (10 ft.).
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
29
CMAC 5211
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 51-IS
Note: The CMSS 6195 Laser Reference Kit (CMVA
version kit) or CMSS 6155 Optical Phase
Reference Kit (CMVA 60 version kit) requires a
CMAC 5211 BNC tachometer cable to work with the SKF Microlog.
The CMAC 5213 laser tachometer cable
connects the tachometer to the SKF
Microlog.
The CMAC 5213 cable is a shorter cable
than is sold in the CMAC 5030K laser
tachometer kit. This cable is only 24 cm
(9.5 in.) long. This shorter cable is preferred
if the user uses the CMAC 5030K kit's
mounting bracket to attach the tachometer
directly to the SKF Microlog.
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
Laser tachometer kit straight
cable, 24 cm (9.5 in.)
• • • •
CMXA 80
CMXA 70-Z2
•
The CMAC 5211 cable connects to the power connector at one end (using the power
connector’s tachometer input pin) and to
any male BNC connector on the other end. It
can be used with any tachometer signal
source that does not require the SKF
Microlog to power it.
• • • •
BNC tachometer straight
cable
CMAC 5213
CMXA 45
CMXA 51-IS
Specifications
Specifications
• Connectors: Fischer type 103 seven pin trigger I/P to BNC
• Length: 1 m (3.28 ft.) straight
• Connectors: Fischer type 103 seven pin to four pin socket
• Length: 24 cm (9.5 in.) straight
Ordering information
Ordering information
CMAC 5211 BNC tachometer straight cable.
CMAC 5213 Laser tachometer kit straight cable, 24 cm (9.5 in.).
30
CMAC 5036
CMAC 5214
CMXA 48
CMXA 75
CMXA 70 / 44
CHX signal input straight extension cable, 5 m (16.4 ft.)
The CMAC 5036 cable, which is used for the
CHX signal input, is a straight extension
cable that is 5 m (16.4 ft.) long. This cable
can be used with single channel and triax
sensors.
CMXA 45
CMXA 51-IS
Specifications
• • • • • •
CMXA 80
CMXA 70-Z2
•
The CMAC 5214 laser tachometer cable
connects the tachometer to the SKF
Microlog.
The CMAC 5214 cable, which is also
included in the CMAC 5030K laser tachometer kit, allows the user to place the
CMAC 5030K tachometer on a stationary
surface up to 2 m (6.56 ft.) away from the
SKF Microlog.
• • • •
Laser tachometer kit straight
cable, 2 m (6.56 ft.) for
CMAC 5030K
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
• Connectors: Fischer type 103 six pin
female to Fischer type 103 six pin male
• Length: 5 m (16.4 ft.) straight
Specifications
• Connectors: Fischer type 103 seven pin to
four pin socket
• Length: 2 m (6.56 ft.) straight
Ordering information
Ordering information
CMAC 5214 Laser tachometer kit straight cable, 2 m (6.56 ft.).
CMAC 5036 CHX signal input straight extension cable, 5 m (16.4 ft.).
31
CMAC 5037
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
Tachometer straight extension cable, 5 m (16.4 ft.)
The CMAC 5043 straight extension cable is
for use with the CMAC 5030K laser tachometer kit. This cable is 5 m (16.4 ft.) long. This
cable can be used in conjunction with
CMAC 5023 or CMAC 5088 cables for other
tachometers that are supplied.
CMXA 51-IS
• Connectors: Fischer type 103 six pin
female to Fischer type 103 six pin male
• Length: 10 m (32.8 ft.) straight
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
Specifications
CMXA 80
• • • •
The CMAC 5037 cable, which is used for the
CHX signal input, is a straight extension
cable that is 10 m (32.8 ft.) long. This cable
can be used with single channel and triax
sensors.
• • • • • •
CHX signal input straight extension cable, 10 m (32.8 ft.)
CMAC 5043
CMXA 45
CMXA 51-IS
Specifications
• Connectors: Fischer type 103 seven pin
female to Fischer type 103 seven pin
male
• Length: 5 m (16.4 ft.) straight
Ordering information
Ordering information
CMAC 5037 CHX signal input straight extension cable, 10 m (32.8 ft.).
CMAC 5043 Tachometer straight extension cable, 5 m (16.4 ft.).
32
CMAC 5044
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 45
CMXA 51-IS
Specifications
• Connectors: Fischer type 103 seven pin
female to Fischer type 103 seven pin
male
• Length: 10 m (32.8 ft.) straight
Cable converter, two pin MIL
to BNC
The CMAC 3715 adapter, when combined
with the CMAC 5209 accelerometer cable,
allows the SKF Microlog to connect to any
male BNC connector. This is useful for
reading buffered outputs from protection
systems, switch boxes or process signal
sources.
The adapter does not block DC signals, so
the user must be careful to avoid applying
power to a buffered signal output.
• • • • • •
CMXA 80
CMXA 70-Z2
•
The CMAC 5044 straight extension cable is
for use with the CMAC 5030K laser tachometer kit. This cable is 10 m (32.8 ft.) long.
This cable can be used in conjunction with
CMAC 5023 or CMAC 5088 cables for other
tachometers that are supplied.
• • • •
Tachometer straight extension cable, 10 m (32.8 ft.)
CMAC 3715
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
Specifications
• Connectors: Two pin MIL to BNC
• Length: 8,5 cm (3.35 in.)
Ordering information
Ordering information
CMAC 5044 Tachometer straight extension cable, 10 m (32.8 ft.).
CMAC 3715 Cable converter, two pin MIL to BNC.
33
CMAC 5019
CMXA 80
Signal input straight cable
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 51-IS
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
The CMAC 5023 cable connects to the SKF
Microlog's CH1 or CH2 signal input connector at one end (using the input connector’s
CHX / CH1 input pin) and to any male BNC
connector at the other end. This lightweight
cable is also used in the CMAC 5056,
CMAC 5057 and CMAC 5058 modal analysis
hammer kits.
• • • •
The CMAC 5019 four-core shielded USB
cable has a standard USB Type A plug. The
cable is used for USB communications and
power without the docking station.
The USB Type A plug is used to connect to
the PC, while the in-line DC jack socket connects to the CMAC 5090 universal power
supply and the Fischer plug connects to the
SKF Microlog,
• • • • • •
USB communication / power
splitter straight cable
CMAC 5023
CMXA 45
CMXA 51-IS
Note: Refer to CMAC 5088 for a heavy duty
version of this cable.
Specifications
• Connectors: USB Type A and a standard 2,1 mm (0.083 in.)
in-line DC jack socket to Fischer SE103A057-130 plug
• Length: 2 m (6.56 ft.) straight
Specifications
• Connectors: Fischer type 103 six pin CH1 I/P to BNC
• Length: 1 m (3 ft.) straight
Ordering information
Ordering information
CMAC 5019 USB communication / power splitter straight cable.
CMAC 5023 Signal input straight cable.
34
CMAC 5032
CMAC 5078
CMXA 75
CMXA 70 / 44
The CMAC 5078 cable connects the
CMAC 5403 headphones to the SKF
Microlog.
CMXA 51-IS
CMXA 48
CMXA 75
CMXA 70-Z2
Specifications
• Connectors: Fischer type 103 seven pin to
female audio
• Length: 20 cm (7.9 in.) straight
Ordering information
Ordering information
CMAC 5032 Power / trigger splitter straight cable.
CMAC 5078 Audio headphone straight cable.
•
• Connectors: One Fischer type 103 seven
pin plug to two Fischer type 103 seven
pin sockets
• Length: 30 cm (11.8 in.)
• Cable: Eight-core 24 AWG screened cable
CMXA 45
CMXA 80
CMXA 70 / 44
CMXA 70-Z2
•
Specifications
• •
The CMAC 5032 cable allows the connection
of the tachometer, instrument power and
USB communications (via the CMAC 5019
cable) simultaneously.
CMXA 48
Audio headphone straight
cable
• • •
CMXA 80
Power / trigger splitter
straight cable
CMXA 45
CMXA 51-IS
35
CMAC 5082
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
Temperature gun interface
straight cable
The CMAC 5087 cable is used to connect the
CMAC 4200-K-SL infrared thermometer to
the SKF Microlog.
• • • •
The CMAC 5082 USB cable is used to connect the CMAC 5068 docking station to the
PC.
• •
USB / A to B straight cable
CMAC 5087
CMXA 70-Z2
• Connectors: USB Type A to USB Type B
• Length: 2 m (6.56 ft.) straight
CMXA 45
CMXA 51-IS
Specifications
• Connectors: Fischer type 103 six pin to
input adapter
• Length: 1,5 m (4.9 ft.) straight
Ordering information
Ordering information
CMAC 5082 USB / A to B straight cable.
CMAC 5087 Temperature gun interface straight cable.
36
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
Specifications
CMXA 80
CMXA 45
CMXA 51-IS
CMAC 5088
CMXA 80
CMXA 75
CMXA 70 / 44
CMXA 48
CMXA 75
The CMAC 5116 cable is offered as an
optional accessory. It is not part of the
CMXA 51-IS ATEX certification; therefore, it
must be approved by the site’s safety officer
before use in a hazardous area.
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 45
Specifications
•
CMXA 51-IS
Note: Refer to CMAC 5023 for a lightweight
version of this cable.
CMXA 80
AC / DC signal coiled cable
CMXA 48
CMXA 70-Z2
•
The CMAC 5088 cable is a heavy duty version of the CMAC 5023 cable. The
CMAC 5088 cable connects to the SKF
Microlog's CH1 or CH2 signal input connector at one end (using the input connector’s
CHX / CH1 input pin) and to any male BNC
connector at the other end.
• • • •
Signal input straight cable
CMAC 5116
CMXA 51-IS
• Connectors: Fischer four pin to BNC
• Length: 2 m (6.56 ft.) coiled
Specifications
• Connectors: Fischer type 103 six pin CH1
I/P to BNC
• Length: 1,8 m (6 ft.) straight
Ordering information
Ordering information
CMAC 5088 Signal input straight cable.
CMAC 5116 AC / DC signal coiled cable.
37
CMAC 5117
CMAC 5201
CMXA 80
Trigger coiled cable
CMXA 80
Serial communication cable
CMXA 48
CMXA 75
The CMAC 5117 cable is offered as an
optional accessory. It is not part of the
CMXA 51-IS ATEX certification; therefore, it
must be approved by the site’s safety officer
before use in a hazardous area.
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
The CMAC 5201 cable has nine pins (female
at both ends) that all connect straight
through. It is required for uploading / downloading data between the host computer
and the SKF Microlog GX series.
For uploading to laptop computers with a
USB connection, there is no USB to Serial
cable available for the GX series from SKF;
however, an aftermarket USB adapter may
be purchased at most electronics stores or
via the web.
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
•
• Connectors: Fischer three pin to BNC
• Length: 2 m (6.56 ft.) coiled
•
Specifications
CMXA 48
Specifications
• Connectors: Nine pin female to nine pine female
• Length: 1,8 m (6 ft.)
Ordering information
Ordering information
CMAC 5117 Trigger coiled cable.
CMAC 5201 Serial communication cable.
38
CMXA 51-IS
CMAC 5404
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
Strobe light output straight
cable
The CMAC 5406 cable is used for output
from the CMSS 6165 strobe light to the
SKF Microlog.
• • • •
The CMAC 5404 cable is used for input to
the CMSS 6165 strobe light from the
SKF Microlog.
• • • •
Strobe light input straight
cable
CMAC 5406
CMXA 70-Z2
CMXA 45
CMXA 51-IS
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
Specifications
• Connectors: Fischer type 103 seven pin to
output adapter
• Length: 2 m (6.56 ft.) straight
Ordering information
Ordering information
CMAC 5404 Strobe light input straight cable.
CMAC 5406 Strobe light output straight cable.
•
• Connectors: Fischer type 103 seven pin to
input adapter
• Length: 1,8 m (6 ft.) straight
•
Specifications
CMXA 80
CMXA 45
CMXA 51-IS
39
40
Hardware
Infrared thermometer, CMAC 4200-K-SL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42
Laser tachometer kit, CMAC 5030K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
44
Modal analysis hammer kit, CMAC 5056 / CMAC 5057 / CMAC 5058 . . . . . . . . . . . . .
45
ICP microphone with integral preamplifier kit, CMAC 5084 . . . . . . . . . . . . . . . . . . . .
48
AC / DC current clamp, CMAC 5208 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
49
Microlog Analyzer field balancing accessory kit, CMCP 850-01 / CMCP 850-02 /
CMCP 850-03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51
Optical phase reference kit, CMSS 6155XK-U-CE . . . . . . . . . . . . . . . . . . . . . . . . . . . .
52
Optical phase reference magnetic holder, CMSS 6156 . . . . . . . . . . . . . . . . . . . . . . . .
55
Strobe light kit, CMSS 6165K-AX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
56
Smart laser sensor tachometer, CMSS 6195AX-K . . . . . . . . . . . . . . . . . . . . . . . . . . .
59
41
CMAC 4200-K-SL
• • • •
Infrared thermometer
The SKF CMAC 4200-K-SL infrared thermometer
with laser sighting is a rugged, easy to use, portable,
non-contact thermometer. Ideal for a broad range off
maintenance tasks, the CMAC 4200-K-SL may be
connected directly to the SKF Microlog series analyz-ers for quick, accurate recording of surface temperatures. It is one of a variety of accessories offered by
SKF to work with the SKF Microlog in enhancing the
gram.
overall effectiveness of a predictive maintenance program.
nfrared energy
The CMAC 4200-K-SL measures the amount of infrared
emitted by an object and converts it to a display of thee object’s surter takes nonface temperature. The handheld, infrared thermometer
contact temperature measurement technology to a new level.
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
CMXA 51-IS
Features
•
•
•
•
•
•
Designed for physically challenging environments
Easy to use
Adjustable emissivity with on-board table
Fast response time
Accuracy ±1% of reading
Wide temperature range
Specifications
Graphic display
View more information at a glance. The CMAC 4200-K-SL infrared
thermometer automatically creates a graphic display of the last 10
temperature points measured using the maximum and minimum
temperature values to establish the range.
Alarm light
Laser
indicator
Bar graph display
Battery
indicator
Emissivity
Graphic display
42
• Temperature range: –30 to +900 °C (–25 to +1 600 °F)
• Display resolution: 0,1 °C (0.2 °F)
• Accuracy:
– ±1% of reading, or ±1 °C (±2 °F), whichever is greater at
23 °C (73 °F)
– ±2 °C (±4 °F) for targets below 0 °C (32 °F)
• Repeatability: ±0,5% of reading, or ±1 °C (±2 °F)
• Response time (95%): 250 ms
• Spectral response: 8 to 14 microns
• Optical resolution: 60:1
• Ambient operating range: 0 to 50 °C (32 to 122 °F); Laser
maximum 45 °C (113 °F)
• Relative humidity: 10 to 95%, non-condensing at up to 30 °C
(86 °F)
• Storage temperature: –20 to +50 °C (–4 to +120 °F) without
battery
• Analog output: 1 mV/°C (mV/°F)
• Power: Two 1,5 volt “AA” alkaline batteries
• Tripod mount: 1/4-20 UNC
• Dimensions: 200 × 170 × 50 mm (7.9 × 6.7 × 2.0 in.)
• Weight: 480 g (22 oz.)
Kit contents
•
•
•
•
•
CMAC 4200: Infrared thermometer
CMAC 5087: Temperature gun interface cable
31784200 Nylon belt holster
31678902 Hard carrying case
Operator's guide
CMAC 4200 Infrared thermometer
CMAC 5087 Temperature gun interface cable
31784200 Nylon belt holster
31678902 Carrying case
Ordering information
CMAC 4200-K-SL Infrared thermometer with adapter, standard connection cable, operator’s guide, nylon holster and hard carrying case.
Optional accessories
• 31784200 Nylon belt holster for infrared thermometer
• 31678902 Hard plastic carrying case
• CMAC 5087 Temperature gun interface cable
43
CMAC 5030K
• • • •
Laser tachometer kit
The CMAC 5030K laser tachometer kit contains a small tachometer for easy mounting.
Along with the tachometer, this kit includes
a bracket for mounting the tachometer
directly to the SKF Microlog using the camera mount located on the bottom of the SKF
Microlog. The kit also includes a two-meter
cable to connect the tachometer to the SKF
Microlog and a small tripod for a stationary
mounting of the tachometer during the
measurement. The key features of this laser
tachometer kit include:
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
•
•
•
•
•
CMXA 80
CMXA 45
CMXA 51-IS
Operating frequency up to 250 000 rpm
Long optical range, up to 2 m (6.56 ft.)
Wide angle of operation, up to 80°
On target indicator standard
Protection rating: IP 67
Specifications
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Material: Stainless steel body
Color: Silver
Laser type: Class 2
Optical range: 100 to 2 000 mm (0.33 to 6.56 ft.)
Power: 1 mW maximum
Current consumption: 45 mA maximum
Cable: Fischer seven pin type 103 to four pin socket, 2 m (6.56 ft.)
Wavelength: 635 mm (25 in.)
Angle of incidence: ±80°
Speed range: 0,1 to 250 000 rpm
Power input: 5 V DC or 8-24 V DC versions at 30 mA typically
Operating temperature: –10 to +40 °C (14 to 104 °F)
IP rating: IP 67
Housing types: M20 threaded or plain body plus fixing slots
Connections: Integral connector
Dimensions: 70 × 20 mm (2.76 × 0.79 in.)
Weight: 70 g (2.5 oz.)
Kit contents
•
•
•
•
•
Compact laser tachometer
Mounting bracket
Reflective tape strips
Mini mounting tripod
CMAC 5214: Tachometer interface cable, 2 m (6.56 ft.)
Compact laser
tachometer
Mini mounting tripod
Mounting bracket
Reflective tape strips
CMAC 5214 Tachometer interface cable
Ordering information
CMAC 5030K Laser tachometer kit. Each kit includes a compact laser
tachometer, mounting bracket, cable and mini tripod.
44
CMAC 5056 / CMAC 5057 / CMAC 5058
• • • •
Modal analysis hammer kit
Features
•
•
•
•
Frequency range up to 8 kHz
Peak force 2 200 N (500 lb. ft.)
Output 2,25 mV/N (10 mV/lb. ft.)
Mass extender to provide additional force
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
These calibrated modal hammer kits may be
used for impulse testing of the dynamic behavior of mechanical structures by striking the
object with the hammer and measuring the
resulting response with the accelerometer. The
hammer imparts a constant force over a broad
frequency range, which depends on the type of
tip used.
The hammer has an integral, ICP quartz
force sensor mounted on the striking end of the hammer head. The
sensor converts the impact force into electrical signal for display and
analysis.
It is designed with rigid quartz crystals and a built-in, microelectronic, unity gain amplifier. Due to the laser-welded construction of
the sensor element, operation is reliable in adverse environments.
The striking end of the hammer has a threaded hole for installation of a variety of impact tips that are included in the kit. The tip
transfers the impact force to the sensor and protects the sensor face
from damage. Tips of different stiffness allow the variation of the
pulse width and correspondingly the frequency content of the force.
Modal analysis and modeling is also available by fixing the accelerometer at one location, impacting the structure at one point and
then moving the accelerometer to other points of interest. When
used with the FRF module, the following modal parameters can be
calculated and displayed:
• Apparent mass / accelerance
• Impedance / mobility
• Stiffness / compliance
Specifications
CMAC 5056 Accelerometer (353B04)
Dynamic
• Sensitivity (±5%): 1,02 mV/(m/s2) (10 mVg)
• Measurement range: ±4 905 m/s2 peak (±500 g peak)
• Frequency range:
– ±5%: 1 to 7 000 Hz
– ±10%: 0,7 to 11 000 Hz
– ±3 dB: 0,35 to 20 000 Hz
• Resonant frequency: ≥38 kHz
• Broadband resolution (1 to 10 000 Hz): 0,03 m/s2 RMS
(0.003 g RMS)
• Non-linearity: ≤1%
• Transverse sensitivity: ≤5%
CMXA 51-IS
Electrical
•
•
•
•
•
•
•
Excitation voltage: 18 to 30 V DC
Constant current excitation: 2 to 20 mA
Output impedance: ≤100 Ω
Output bias voltage: 8 to 12 V DC
Discharge time constant: 0,5 to 2,0 s
Settling time (within 10% of bias): <5 s
Spectral noise:
– 1 Hz: 3 200 μg/√Hz
– 10 Hz: 700 μg/√Hz
– 100 Hz: 180 μg/√Hz
– 1 kHz: 64 μg/√Hz
Environmental
• Overload limit (shock): ±98 100 m/s2 pk (±10 000 g pk)
• Temperature range (operating): –54 to +121 °C (–65 to +250 °F)
• Base strain sensitivity: ≤ 0,0005 g/μ strain
Physical
•
•
•
•
•
•
•
•
•
Size (hex × height): 12,7 × 29,0 mm (0.50 × 1.14 in.)
Weight: 10,5 g (0.38 oz.)
Sensing element: Quartz
Sensing geometry: Shear
Housing material: Titanium
Sealing: Welded hermetic
Electrical connector: 10-32 coaxial jack
Electrical connection position: Top
Mounting thread: 10-32 female
45
CMAC 5057 Accelerometer (353B16)
Dynamic
• Sensitivity (±10%): 1,02 mV/(m/s2) (10 mVg)
• Measurement range: ±4 905 m/s2 peak (±500 g peak)
• Frequency range:
– ±5%: 1 to 10 000 Hz
– ±10%: 0,7 to 20 000 Hz
– ±3 dB: 0,35 to 30 000 Hz
• Resonant frequency: ≥70 kHz
• Broadband resolution (1 to 10 000 Hz): 0,05 m/s2 RMS
(0.005 g RMS)
• Non-linearity: ≤1%
• Transverse sensitivity: ≤5%
Electrical
•
•
•
•
•
•
•
Excitation voltage: 18 to 30 V DC
Constant current excitation: 2 to 20 mA
Output impedance: ≤100 Ω
Output bias voltage: 8 to 12 V DC
Discharge time constant: 0,5 to 2,0 s
Settling time (within 10% of bias): <5 s
Spectral noise:
– 1 Hz: 3 200 μg/√Hz
– 10 Hz: 700 μg/√Hz
– 100 Hz: 180 μg/√Hz
– 1 kHz: 64 μg/√Hz
Environmental
• Overload limit (shock): ±98 100 m/s2 pk (±10 000 g pk)
• Temperature range (operating): –54 to +121 °C (–65 to +250 °F)
• Base strain sensitivity: ≤ 0,002 g/μ strain
Kit contents
The CMAC 5056 and CMAC 5057 hammer kits each contain an
accelerometer, while the CMAC 5058 hammer kit does not. The
CMAC 5056 hammer kit can be used on structures with a mass of
210 g (7.6 oz.) and above. The CMAC 5057 hammer kit can be used
on structures with a mass of 56 g (2 oz.) and above.
The accelerometers that are included with the CMAC 5056 and
CMAC 5057 kits are ICP, low impedance, voltage-mode sensors.
Microelectronic, built-in amplifiers standardize sensitivities within a
few percent of nominal value.
CMAC 5056 / CMAC 5057 / CMAC 5058 kits include
• Calibrated hammer
• Cable – BNC to Fischer six pin (for a sturdier cable, CMAC 5088
may be used)
• Red hammer tips (two)
• White hammer tip
• Black hammer tips (two)
• Steel tip
• Blue tip covers (two)
• Petro wax
• Screws threaded on both ends (two)
• Hammer extender
• Carrying case
CMAC 5056 kit also includes
• 353B04 Accelerometer
• Magnetic accelerometer base
• CMAC 5061: Cable – Fischer six pin to Microdot
CMAC 5057 kit also includes
• 353B16 Accelerometer
• CMAC 5062: Cable – Fischer six pin to Microdot
Physical
•
•
•
•
•
•
•
•
•
•
Size (hex × height): 7,1 × 17,3 mm (0.28 × 0.68 in.)
Weight: 1,5 g (0.05 oz.)
Sensing element: Quartz
Sensing geometry: Shear
Housing material: Titanium
Sealing: Welded hermetic
Electrical connector: 5-44 coaxial
Electrical connection position: Top
Mounting thread: 5-40 male
Mounting torque: 90 to 135 Ncm (9 to 12 in. lbs.)
CMAC 5056 / CMAC 5057 / CMAC 5058 Hammer
Dynamic
• Sensitivity (±15%): 2,25 mV/N (10 mV/lb. ft.)
• Measurement range: ±2 200 N peak (±500 lb. ft. peak)
Impact Tips
• Frequency range:
– Hard tip (−10 dB): 8 kHz
– Medium tip (−10 dB): 2.5 kHz
– Soft tip (−10 dB): 375 Hz
– Super soft tip (−10 dB): 200 Hz
• Resonance frequency: ≥22 kHz
46
Calibrated hammer
353B04
Accelerometer
(CMAC 5056 only)
353B16
Accelerometer
(CMAC 5057 only)
CMAC 5061 Cable (CMAC 5056 only)
CMAC 5062 Cable (CMAC 5057 only)
Magnetic
accelerometer base
(CMAC 5056 only)
Red hammer tip
White hammer tip
Black hammer tip
Steel tip
Blue tip cover
Petro wax
Screw (threaded on
both sides)
BNC to Fischer cable
Carrying case
(contents may vary)
Hammer extender
Ordering information
CMAC 5056 Modal hammer kit – for use on structures with a mass of
210 g (7.6 oz.) and above. Includes hammer, accelerometer, magnetic
mount, adhesive mounting base with Petro wax, two cables, carrying
case, certificate of conformance and calibration certificate.
CMAC 5057 Modal hammer kit – for use on structures with a mass of
56 g (2 oz.) and above. Includes hammer, accelerometer, adhesive
mounting base with Petro wax, two cables, carrying case, certificate of
conformance and calibration certificate.
CMAC 5058 Modal hammer kit includes hammer, BNC cable, carrying
case, certificate of conformance and calibration certificate (accelerometer not included).
47
CMAC 5084
• • • •
ICP microphone with integral
preamplifier kit
The CMAC 5084 ICP microphone kit contains an array microphone for general purpose use. The ICP powered microphone
enables acoustic type monitoring and is
designed with a preamplifier. A CMAC 5023
signal input cable (Fischer six pin to BNC) is
included to allow connection to the SKF
Microlog. The kit also includes a calibration
certificate.
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
CMXA 51-IS
Specifications
Dynamic
•
•
•
•
•
•
Frequency response (±2 dB): 20 to 10 000 Hz
Frequency response (–2 to +5 dB): 20 to 20 000 Hz
Sensitivity (at 1 kHz): 45 mV/Pa
Inherent noise (1/3 octave at 250 kHz): <15 dB
Inherent noise (A weighted): <30 dB
Dynamic range (3% distortion limit): >122 dB
Electrical
•
•
•
•
Excitation voltage: 18 to 30 V DC
Constant current excitation: 2 to 20 mA
Output bias voltage: 5,5 to 14 V DC
Output impedance: 150 Ω
Environmental
• Temperature range (operating): –10 to +50 °C (14 to 122 °F)
Physical
•
•
•
•
•
•
Weight: 18,5 g (0.66 oz.)
Size (overall): 12,7 × 66,2 mm (0.50 × 2.61 in.)
Size (head): 7 × 28 mm (0.28 × 1.10 in.)
Electrical connector (output): BNC jack
Housing material: Stainless steel
Nominal microphone diameter: 6,35 mm (0.25 in.)
Kit contents
• ICP microphone with preamplifier
• CMAC 5023: Signal input cable
• Calibration certificate
CMAC 5023 Cable
ICP microphone with
preamplifier
Ordering information
CMAC 5084 ICP microphone with integral preamplifier kit includes an
ICP microphone with preamplifier, CMAC 5023 cable and a calibration
certificate.
48
CMAC 5208
• • • •
AC / DC current clamp
The CMAC 5208 AC / DC current clamp is a battery-powered clampon current probe that is used on primary circuits with the SKF
Microlog Analyzer to measure AC or DC currents up to 600 amps
peak AC, 600 amps DC.
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
Features
•
•
•
•
CMXA 80
CMXA 45
CMXA 51-IS
Solid state hall effect transducer
AC (1 Hz to 5 kHz) and DC (0 to 1 Hz) measurement
Ranges: 60 and 600 amps
Degaussing adjustment for zero noise offset
The AC / DC current clamp allows a user to easily and safely incorporate current monitoring within SKF Microlog routes. The jaws clamp
around a conductor allowing current measurements without breaking the circuit. A Hall Sensor mounted in a gap in the core senses the
magnetic field produced by the current being measured. An amplifier circuit generates an output signal of 1 mV per amp (600 amp
range) or 10 mV per amp (60 amp range). Demagnetizing (degaussing) is accomplished by means of a push-button.
Lightweight and easy to carry, the AC / DC current clamp may be
used throughout the plant or in control room environments. This
current clamp is equipped with a connector that fits the CH1 or CH2
input connectors.
Electrical (continued)
Specifications
Electrical
• Current range:
– 40 A (AC) / 60 A (DC) range: 0,2 to 40 A (AC), (60 A peak) 0,4 to
60 A (DC)
– 400 A (AC) / 600 A (DC) range: 0,5 to 400 A (AC), (600 A peak)
0,5 to 600 A (DC)
• Output signal:
– 40 A (AC) / 60 A (DC) range: 10 mV/A
– 400 A (AC) / 600 A (DC) range: 1 mV/A on 600 A range on
600 A (DC)
• Output termination: 1,8 m (6 ft.) BNC
• Overload: 1 000 A (AC) and 2 000 A (DC) continuous up to 1 kHz
• Rise and fall time:
– 60 A range: ≤100 μs from 10 to 90% Vout
– 600 A range: ≤70 μs from 10 to 90% Vout
• Insertion impedance:
– 0,39 mΩ at 50 Hz
– 58 mΩ at 1 000 Hz
• Load impedance: >100 kΩ/100 pF (maximum)
• Frequency range: DC to 10 kHz at −3 dB
• Working voltage: 600 V RMS
• Common mode voltage: 600 V RMS
• Influence of adjacent conductor: <10 mA/A at 50 Hz at 23 mm
(0.905 in.) from the probe
• Influence of conductor in jaw opening: 0,5% reading (DC to
440 Hz)
• Influence of temperature: ≤300 ppm/°K or 0,3%/10 °K
• Influence of humidity: 10 to 90% relative humidity at reference
temperature ≤0,5%
• Accuracy*:
– 40 A (AC) / 60 A (DC) range:
· 1,5% of reading ±0,5 A (0,5 to 40 A)
· 1,5% of reading (40 to 60 A)
– 400 A (AC) / 600 A (DC) range:
· 1,5% of reading ±1 A (0,5 to 100 A)
· 2,0% of reading (100 to 400 A)
· 2,5% of reading (400 to 600 A DC)
• Phase shift*:
– 40 A (AC) / 60 A (DC) range:
· ≤3° (10 to 20 A, 45 to 65 Hz)
· ≤2° (20 to 100 A)
· ≤1,5° (100 to 400 A)
– 400 A (AC) / 600 A (DC) range:
· ≤3° (10 to 100 A)
· ≤1,5° (100 to 400 A)
* Reference conditions: 18 to 28 °C (64 to 84 °F), 20 to 75% relative
humidity, external magnetic field <40 A/m, no DC component, no external
current carrying conductor, test sample centered, 1 MΩ ≤ 100 pF load,
zero adjustment prior to measurement (DC only) DC to 65 Hz, battery
voltage = 9 V, ±0,1 V.
49
Electrical (continued)
Mechanical
• Noise:
– 60 A range:
· DC to 1 kHz: ≤8 mV or 0,8 A PP
· DC to 5 kHz: ≤12 mV or 1,2 A PP
· 0,1 Hz to 5 kHz: ≤2 mV or 0,2 A PP
– 600 A range:
· DC to 1 kHz: ≤1 mV or 1 A PP
· DC to 5 kHz: ≤1,5 mV or 1,5 A PP
· 0,1 Hz to 5 kHz: ≤500 μV or 0,5 A PP
• Auto off: 10 minutes (may be disabled at power up)
• Electrical certification: EN 61010-2-32
•
•
•
•
•
Environmental
•
•
•
•
Case protection: IP 30 per IEC 529
Operating temperature range: −10 to +55 °C (14 to 131 °F)
Storage temperature range: −40 to +70 °C (–40 to +176 °F)
Operating relative humidity:
– 10 to 35 °C (50 to 95 °F), 90% ±5% relative humidity (without
condensation)
– 40 to 55 °C (104 to 131 °F), 70% ±5% relative humidity (without condensation)
• Altitude:
– Operating: 0 to 2 000 meters (0 to 6 500 ft.)
– Non-operating: 0 to 12 000 meters (0 to 39 000 ft.)
•
•
•
•
•
•
•
Zero adjustment: Automatic zero
Battery: 9 V alkaline
Low battery indication: Green LED when battery voltage ≥6,5 V
Battery life: Approximately 120 hours with alkaline battery
Overload indication: Red LED indicates input greater than the
selected range
Jaw opening: 31 mm (1.2 in.)
Maximum conductor size:
– One 30 mm (1.18 in.) conductor, or
– Two 24 mm (0.95 in.) conductors, or
– Two bus bars 31,5 × 10,0 mm (1.24 in. × 0.40 in.)
Dimensions: 224 × 97 × 44 mm (8.80 × 3.82 × 1.73 in.)
Weight: 440 g (15 oz.)
Vibration: Test per IEC 68-2-6
Frequency range:
– 5 to 15 Hz, Amplitude: 1,50 mm (0.06 in.)
– 15 to 25 Hz, Amplitude: 1,00 mm (0.04 in.)
– 25 to 55 Hz, Amplitude: 0,25 mm (0.01 in.)
Mechanical shock: 100 G, test per IEC 68-2-27
Material
• Output lead: Double / reinforced insulated 1,5 m (5 ft.)
• Handle: Gray polycarbonate + ABS, UL94 V0
• Jaws: Red polycarbonate, UL94 V0
Ordering information
CMAC 5208 AC / DC current clamp, includes an integral cable that
connects directly to the SKF Microlog.
50
• • • •
CMCP 850-01 / CMCP 850-02 /
CMCP 850-03
SKF Microlog Analyzer field balancing
accessory kit
Features
The SKF Microlog analyzer field balancing accessory kit contains all of the accessories necessary
to perform in-place field balancing of rotating
machinery. This is a complete kit that provides
the necessary transducers, magnetic bases,
A / B switch, cables, trial weight kit, precision
electronic balance scale, and more, all packaged
in a rugged, watertight, hard case that makes
balancing easier and more accurate. With the flip of a switch, two
channels of vibration data can be input into the SKF Microlog. This
eliminates the need to keep moving the vibration sensor back and
forth between balance planes. A variety of adapters are included so
that you can hook the SKF Microlog to other sensor sources, such as
on-line systems and velocity probes.
The CMCP 850 is a complete kit for the SKF Microlog. In short, all
you need to add is an SKF Microlog and you are ready to balance
pumps, fans, motors, couplings, small turbines and more.
Field balancing kits are available with either the optical or laser
phase kits or a laser tachometer kit.
Kit contents
CMCP 850-01 (with Optical Sensor) kit includes
• CMSS 6155XK-U-CE: Optical phase reference kit with universal
power supply
CMCP 850-02 (with Laser Sensor) kit includes
• CMSS 6195AX-K: Laser phase reference kit with universal power
supply
CMCP 850-03 (with Laser Sensor) kit includes
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
Two accelerometers with magnetic bases
Choice of optical or laser phase reference kit
7,6 m (25 ft.) cables
Precision electronic balance scale
Large trial weight kit
Packaged in a rugged, watertight, hard carrying case
•
•
•
•
•
•
•
CMXA 80
CMXA 45
CMXA 51-IS
CMCP 850-01 / CMCP 850-02 / CMCP 850-03 kits include
• CMSS 2100: Accelerometers (two)
• CMSS 908-MD: Medium duty magnetic bases for
accelerometers (two)
• CMCP 811: Set of assorted balance weights
• CMCP 625: Two pin 5015 to BNC adapters (two)
• CMSS 6156: Magnetic holder
• CMCP 665-6PIN: 7,6 m (25 ft.) BNC to Fisher 103 six pin
accelerometer cables (two)
• CMCP 665-7PIN: 7,6 m (25 ft.) BNC to Fisher 103 seven pin
accelerometer cables (two)
• CMSS T-5: Roll of reflective tape
• 600 g (21.164 oz.) digital scale
• Custom vise grips with M8 thread
• Banana to BNC adapters (three)
• Hex key set
• Tape measure (English / Metric)
• Stainless steel rule: 15,2 cm (6 in.) (English / Metric)
• Protractor: 180°, 15,2 cm (6 in.)
• Compass
• Clipboard with storage
• Polar plot tablet
• Application notes
• Watertight, hard carrying case
• CMAC 5030K: Laser tachometer kit, SKF Microlog powered
Ordering information
CMCP 850-01 Microlog Analyzer field balancing accessory kit with
optical sensor.
CMCP 850-02 Microlog Analyzer field balancing accessory kit with laser
sensor.
CMCP 850-03 Microlog Analyzer field balancing accessory kit with laser
sensor.
51
CMSS 6155XK-U-CE
• • • •
Optical phase reference kit
The CMSS 6155XK-U-CE optical phase reference kit allows
you to easily monitor speed and
phase angles on any operating
machine by triggering off of
reflective tape or paint on the
shaft surface. The optical phase
reference system can measure
speed and provide a trigger for absolute and relative phase measurements at distances up to 0,9 m (3 ft.).
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
Interface module
The purpose of phase measurement
The angular distance between a reference location on a rotating
shaft and some point defined on the shaft's vibration waveform
(such as the high spot or heavy spot) is commonly called the phase
angle. Phase angle is measured for four main reasons:
• Balancing, to locate the proper position on an unbalanced rotor
for adding a compensating weight
• Startup and coast down response, to define critical speeds and to
assess system damping
• Detecting changes in operating balance, to indicate problems such
as changing electrical properties, fan build up and shaft cracks
• Detecting shaft misalignment, resonance and other machinery
problems
The interface module provides an interface between the optical
phase reference sensor and the SKF Microlog. It also provides power
to the sensor. The optical phase reference sensor can typically operate for 40 hours continuously using the interface module's internal
rechargeable batteries, or indefinitely from the external recharger /
power supply (when connected to the interface module).
Features
•
•
•
•
•
•
Single pulse per revolution TTL trigger source
Positive and negative pulse outputs
Self-contained
Rechargeable batteries
Green LED on optical sensor indicates “ON” target operation
Remote wake-up (with Wireless Monitoring System V/T)
Methods for establishing a phase reference
Phase angle measurement requires two inputs: a reference pulse
triggered once each revolution and a vibration signal. The SKF
Microlog triggers off a positive-going or negative-going V DC pulse,
depending on how it is configured in the Trigger Slope polarity setting (+ or –) in Trigger Setup.
The once-per-revolution reference pulse required by the SKF
Microlog is provided by a non-contact optical sensing system that
produces a TTL pulse (5 to 0 V DC) when reflective tape or paint
installed on the rotating shaft passes through the sensor's light
beam, up to a maximum distance of 0,9 m (3 ft.).
The optical phase reference kit consists of a remote optical sensor
equipped with a steady state DC light source and photo detector, an
interface module, on-off switch, BNC connectors, internal rechargeable batteries and a recharger input. A universal plug-in charger
module is also supplied. Standard camera tripods, user-supplied
mounting brackets or the optional magnetic holder with movable
arm (CMSS 6156) may be used for mounting.
The phase angle measuring process
Interface module
The optical phase reference sensor systems for the SKF Microlog
sense machinery speed and output a TTL signal synchronous with
machine speed. This output signal is used by the SKF Microlog to
measure the absolute phase of a vibration signal.
The phase angle measuring process works by aiming the sensor's
light beam, using the optical phase reference sensor, at the reference mark on the rotating shaft. This establishes the zero phase reference relative to the vibration signal component. The vibration
transducer produces a complex vibration signal for the process. The
optical phase reference sensor sends out a phase reference signal to
the SKF Microlog that is synchronous with the shaft speed. The SKF
Microlog then reports the magnitude of the vibration component
and its phase angle in relation to the vibration transducer.
• Power source: Four rechargeable Nickel Metal Hydride NiMH “AA”
batteries provide up to 40 hours of continuous operation; complete recharge requires four hours
• Output signals:
– TTL positive inverting pulse: 0 to 5 V
– TTL negative non-inverting pulse: 5 to 0 V – switch selectable
• Bandwidth: 0 to 100 kHz
• Output connectors: BNC connector (female)
• Pulse width: Determined by size of reflective marker and rotational speed of equipment being monitored
• Operating temperature: 0 to 50 °C (32 to 122 °F)
• Weight: 235 g (8.3 oz.)
• Dimensions: 127 × 64 × 25 mm (5.0 × 2.5 × 1.0 in.)
52
Specifications
Remote optical sensor
• Speed range: 1 to 250 000 RPM
• Operating envelope: Up to 0,9 m (3 ft.) and 45° from reflective
target
• Illumination source: Visible red LED, 5 V DC at 30 mA
• Output signal: 5 to 0 V DC TTL compatible pulse
• On-target indicator: Green LED on end cap
• Material: 303 stainless steel
• Lens: Acrylic plastic
• Cable length: 2,4 m (8 ft.) from sensor to interface module
• Operating temperature: –10 to +70 °C (14 to 158 °F)
• Dimensions: Threaded tube – M16 × 1,5 mm length × 74 mm
diameter (2.9 in. length × 0.625 in. diameter) supplied with two
M16 jam nuts and mounting bracket
CMSS 6155W-U-CE Self-powered sensor
Kit contents
•
•
•
•
•
•
CMSS 6155W-U-CE: Self-powered sensor
CMSS 6155W: Interface module
CMAC 5211: BNC tachometer input cable
CMSS T-5: Reflective tape
Mounting bracket with two M16 jam nuts
Universal recharger / power supply with USA, UK, AUS and EURO
adapter plugs
• User manual
CMSS 6155W Interface module
Universal recharger / power supply with adapters
Mounting bracket and jam nuts
CMSS T-5 Reflective
tape
CMAC 5211 BNC tachometer input cable
53
Optional accessories
CMSS 50401 Extension cable
CMSS 6156 Magnetic holder
Ordering information
CMSS 6155XK-U-CE Optical phase reference kit includes a selfpowered sensor, BNC tachometer input cable and user manual.
Optional accessories
• CMSS 50401 7,5 mm (25 ft.) CMSS 6155W Interface module to
optical sensor extension cable
• CMSS 6156 Optical phase reference magnetic holder with movable
arm and remote optical sensor attachment hardware
• CMSS T-5 Reflective tape for use with remote optical sensor, 1,5 m
(5 ft.) roll × 12,7 mm (0.5 in.) wide
54
CMSS 6156
• • • •
Optical phase reference
magnetic holder
The CMSS 6156 optical phase reference
holder with magnetic base is designed for
use with the CMAC 5030K laser tachometer
kit. It is a magnetic holder with a movable
arm and remote optical sensor attachment
hardware.
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
CMXA 51-IS
Specifications
• Measurements:
– Magnetic base: 62 × 50 × 55 mm
(2.44 × 1.97 × 2.17 in.)
– Height: 240 mm (9.45 in.)
• Clamping force: 780 N
• Accessory mounting: 355,6 mm (14 in.)
camera type stud
Compatibility
The CMSS 6156 optical phase reference
magnetic holder is compatible with the following kits:
• CMSS 6155XK-U-CE Optical phase reference kit
• CMSS 6195AX-K Smart laser sensor tachometer kit
Ordering information
CMSS 6156 Optical phase reference magnetic holder.
55
CMSS 6165K-AX
• • • •
Strobe light kit
•
•
•
•
•
•
•
Balancing
Inspection of high speed rotating parts
Motion analysis or phase shift measurement
Over-speed trip tests
On line coupling inspections
RPM / RPS measurements
All applications suited to a general purpose, phase shifting
stroboscope
Specifications
• Time base: Ultra stable crystal oscillator
• Display: LCD with six numeric digits 12,7 mm (0.5 in.) high
• Indicators: Battery level, on target, TIME, AUTO, ALT, TACH, LOCK
and EXT icons
• Knob adjustment: Digital rotary switch with 36 detents per revolution; velocity sensitive
• Memory: Last setting before power down is remembered and
restored on next power up; nine user flash rates can be set
• Output pulse: 40 μ s positive / negative pulse (menu selectable),
3,3 V DC typical
• Input power: Internal rechargeable batteries 6 V DC, external AC
recharger (115 to 230 V AC)
56
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
The CMSS 6165 is a truly portable, battery-operated stroboscope that is suited for a wide range of industrial applications and is able to interface with the SKF Microlog
CMXA series.
Sturdy and compact, the strobe can be operated anywhere in the plant or field to permit visual inspection
(freeze motion), phase shift studies and digital measurement of rotary, reciprocating or linear motion of various
equipment while it is in operation. The CMSS 6165 strobe
light has a special “tuning” circuit that allows it to track
vibration transducer (accelerometer) signals. This capability makes it different from general purpose strobe lights. It
also has a narrow and wide bandwidth filter selection to
discriminate fundamentals from harmonics. The narrow
bandwidth filter limits the influence of harmonics around
the selected frequency, providing a more stable phase reading.
The CMSS 6165 requires an input signal to synchronize the flash
rate with an external source, typically a vibration transducer in the
tracking mode or optical pickup in the external mode. Using a cable,
this signal is applied to the input jack connector on the side of the
strobe light. The CMSS 6165 generates a tachometer signal available on the output jack. The CMSS 6165K-AX strobe light kit is ideally suited for:
CMXA 80
CMXA 45
CMXA 51-IS
• Light output:
– Average: 11 W at 3 000 flashes per minute (FPM), >13 W
above 3 450 FPM
– Instantaneous (per flash): 230 mJoule typical to 3 450 FPM
• Flash duration: 10 to 25 microseconds (auto adjust with flash
rate)
• Flash tube (lamp) life: 100 million flashes
• Run time: Two hours typical at 1 800 FPM and over one hour at
6 000 FPM with fully charged batteries
• Charge time: Four to five hours typical with PSC-pbxU
• Weight: 0,8505 kg (1.875 lbs.) including batteries
This product is designed to be safe for indoor use under the following conditions (per IEC61010-1):
• Operating temperature*: 0 to 40 °C (32 to 104 °F)
• Humidity: Maximum relative humidity 80% for temperatures up to
31 °C (88 °F), decreasing linearly to 50% relative humidity at
40 °C (104 °F)
• Flash range: 30 to 50 000 FPM
• Tachometer measurements: 5 to 250 000 RPM
• Tracking filter: Selectable wide and narrow bandwidths; the filter
may not lock below 100 FPM
• External input: 10 or 100 mVg accelerometer (powered by an
analyzer or by the strobe, menu selectable)
* Safety thermal feature will set unit into TACH Mode (stops flashing) in the
event of internal overheating.
Note: The CMSS 6165 strobe light is not approved for use in hazardous
locations.
Kit contents
•
•
•
•
•
•
•
•
•
•
CMSS 6165: Strobe light
CMAC 5404: Cable – Input to strobe light from the SKF Microlog
CMAC 5406: Cable – output from strobe light to the SKF Microlog
Accelerometer input cable with BNC connector, 1,8 m (6 ft.)
BNC to BNC union connector
CMAC 5405: Universal power supply / recharger (not compatible
with older SKF Microlog models)
58-100-0290: Strobe light jacket and shoulder strap
58-100-1650: Spare lamp
Protective carrying / storage case
User manual
CMSS 6165 Strobe light
CMAC 5404 Strobe light input cable
CMAC 5406 Strobe light output cable
Accelerometer input cable and BNC to BNC
union connector
CMAC 5405 Universal power supply / recharger
Carrying case (open)
58-100-0290 Strobe light jacket and shoulder
strap
58-100-1650 Spare lamp
Carrying case (closed)
57
Optional accessories
CMSS 6165-SPC Strobe light cover
Ordering information
CMSS 6165K-AX Strobe light kit, includes a strobe light, cables, power
supply, spare lamp, jacket and shoulder strap, carrying case, user manual, certificate of conformance and calibration certificate.
Optional accessories and replacement parts
• CMAC 5404 Cable: Input to CMSS 6165 strobe light from SKF
Microlog
• CMAC 5405 Universal power supply / recharger 115 / 230 V AC for
use with new model CMSS 6165 strobe light
• CMAC 5406 Cable: Output from CMSS 6165 strobe light to SKF
Microlog
• CMSS 6165-SPC Cover, clear plastic, splash-proof for CMSS 6165
strobe light
• 58-100-0290 CMSS 6165 strobe light jacket and shoulder strap for
hands-free transport
• 58-100-1650 Strobe lamp
58
CMSS 6195AX-K
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
The CMSS 6195AX-K smart laser sensor
tachometer from SKF adds a powerful
dimension to the capabilities of the SKF
Microlog Portable Data Collector / FFT Analyzer. Ideal for measurement modes such as
order / tracking analysis and synchronous
time averaging, the smart laser sensor
tachometer is an essential tool for the proactive machinery analyst.
• • • •
Smart laser sensor tachometer
CMXA 45
CMXA 51-IS
Features
• “Smart” auto gain provides best performance in picking up target
reflections
• Up to 19,8 m (65 ft.) maximum distance – sensor to target
• “On Target” indicator allows correct reflection path and accurate
measurement
• Manual sensitivity knob provides dynamic fine-tuning of sensor
response
• On / Off or charge switch
• Power / Battery condition indicator
• Class 3R visible laser and nose piece
• Accurate measurements from low contrast surfaces
• Normal operation in high ambient light environments
• External DC power or recharger port
• Tripod mounting bushing (1/4-20 UNC)
Specifications
• Laser: Visible red laser diode (650 nm) 3 mW peak power
• Classification: Class 3R laser product (per IEC60825-1)
• Beam diameter: 4 × 7 mm (0.157 × 0.275 in.) typical at 2 m
(6.56 ft.)
• Laser diode life: 8 000 hours MTBF
• Operating range: Up to 19,8 m (65 ft.), depending on target
• RPM range: 1 to 150 000 RPM
• Minimum trigger duration: 10 μsec
• Power requirement: Internal rechargeable battery
• Charger: 100 to 240 V AC, 50 to 60 Hz with USA, UK, AUS and
EURO adapter plugs
• Output signals:
– TTL positive inverting pulse: 0 to 5 V
– TTL negative non-inverting pulse: 5 to 0 V
• Output connector: DIN-5
• Indicators: On-target, laser on
• Sensitivity adjust: Single knob on top panel
• Modes: Normal, auto and charging
• Dimensions: 137,41 × 59,69 × 54,36 mm (5.41 × 2.35 × 2.14 in.)
• Weight: 300 g (10.6 oz.), excluding cable
• Mounting: 1/4-20 UNC bushing (tripod mount)
• Temperature:
– Operating: -20 to +50 °C (-4 to +122 °F)
– Storage: -30 to +60 °C (-22 to +140 °F)
• Humidity: 90% relative humidity, non-condensing
59
Kit contents
• CMSS 6195A: Self-powered sensor with smart laser sensor
tachometer
• CMAC 5211: BNC tachometer input cable
• SLS-CA-BNC: BNC to five pin DIN cable, 2,5 m (8 ft.)
• 115 / 230 V AC universal charger with adapter plugs
• BNC to BNC coupling
• CMSS T-5: Reflective tape
CMSS 6195A Self-powered sensor with smart
laser tachometer
SLS-CA-BNC cable
Universal charger with adapter plugs
CMAC 5211 BNC tachometer input cable
BNC to BNC coupling
CMSS T-5 Reflective
tape
Optional accessories
Ordering information
CMSS 6195AX-K Smart laser sensor tachometer kit, includes a selfpowered sensor complete with a smart laser sensor tachometer,
115 V AC / 230 V AC universal charger with USA, UK, AUS and EURO
adapter plugs, 2,5 m (8 ft.) SLS-CA-BNC cable and reflective tape.
Optional accessories
• CMSS 6156 Magnetic holder with movable arm and laser sensor
attachment hardware
• CMSS T-5 Reflective tape for use with the smart laser sensor
tachometer, 1,5 m × 12,7 mm (5 ft. × 0.5 in.)
CMSS 6156 Magnetic holder
60
Power
Battery (CMXA 45, CMXA 70, CMXA 75), CMAC 5031 . . . . . . . . . . . . . . . . . . . . . . . . .
62
Battery (CMXA 48, CMXA 80), CMAC 5070. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
63
Universal power supply (non-IS), CMAC 5090 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
64
Battery (CMXA 51-IS), CMAC 5105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
64
Power supply (CMXA 51-IS), CMAC 5110. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65
Strobe light power supply, CMAC 5405 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65
61
CMAC 5031
CMXA 80
Battery
CMXA 48
• •
The 7,4 V Lithium-Ion 2,2 Ah rechargeable
battery pack provides customers with nine
hours of continuous data collection or 26
hours idle. The charging time is 2,5 hours.
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
Specifications
CMXA 45
CMXA 51-IS
Electrical
• Nominal voltage: 7,4 V
• Nominal capacity: 2,2 Ah
• Operating time:
– Nine hours continuous data collection
– 26 hours idling in a process product
• Charge time: 2,5 hours
Environmental
• Temperature range:
– Charging: 0 to 45 °C (32 to 113 °F)
– Discharging: –20 to +60 °C (–4 to +140 °F)
– Storage:
· 1 month: –20 to +60 °C (–4 to +140 °F)
· 3 months: –20 to +45 °C (–4 to +113 °F)
· 1 year: –20 to +20 °C (–4 to +68 °F)
Physical
• Dimensions: 70,5 × 38,5 × 20,5 mm (2.78 × 1.52 × 0.81 in.)
• Weight: 105 g (3.7 oz.)
Protection
•
•
•
•
Over current (A):
Short-circuit (A):
Over voltage (V):
Under voltage (V):
Minimum
5,06
13,11
8,65
4,40
Typical
5,91
17,72
8,70
4,60
Maximum
6,51
21,81
8,75
4,80
Approvals
• Emissions: EN61000-6-4:2001 Severity Level Class A
• Immunity: EN61000-6-2:2001 Severity Level Class A
• CSA: Class I, Division 2 Gas groups A, B, C and D (Canadian and
US standards)
• Transportation: UN Directive ST / SG / AC10 / 27 Add.2
• Equivalent Lithium content: 1,32 g (0.0466 oz.)
Ordering information
CMAC 5031 Battery.
62
CMAC 5070
• •
Battery
CMXA 80
CMXA 48
CMXA 75
The 7,2 V Lithium-Ion 6 600 mAh
rechargeable battery pack provides customers with eight hours of continuous data collection or 10 hours idle. Charging time is six
hours. The battery can be charged in the
instrument through the docking station
(CMAC 5068) or with an external battery
charger (CMAC 5076).
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
Specifications
Electrical
• Nominal voltage: 7,4 V
• Nominal capacity: 6,6 Ah
• Operating time:
– Eight hours continuous data collection
– Ten hours idling in a process product
• Charge time: 6 hours (in suspend mode)
Environmental
• Temperature range:
– Charging: 10 to 45 °C (50 to 113 °F)
– Discharging: –10 to +60 °C (14 to 140 °F)
– Storage (1 year): –20 to +20 °C (–4 to +68 °F)
Physical
• Dimensions: 110,3 × 19,5 × 72,0 mm (4.34 × 0.77 × 2.83 in.)
• Weight: 290 g (10.2 oz.)
Protection
•
•
•
•
Over current (A):
Short-circuit (A):
Over voltage (V):
Under voltage (V):
Minimum
5,00
14,82
8,65
4,40
Typical
8,33
33,33
8,70
4,60
Maximum
8,89
43,61
8,75
4,76
Approvals
• Emissions: EN61000-6-4:2001 Severity Level Class A
• Immunity: EN61000-6-2:2001 Severity Level Class A
• CSA: Class I, Division 2 Gas groups A, B, C and D (Canadian and
US standards)
• Transportation: UN Directive ST / SG / AC.10 / 11 / Rev.3
• Equivalent Lithium content: 3,96 g (0.1397 oz.)
Ordering information
CMAC 5070 Battery.
63
CMAC 5090
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 48
CMXA 75
The CMAC 5105 battery is the only ATEX
certified battery pack to be used with the
CMXA 51-IS unit. Please read the Battery
Documentation in the CD included in all
applicable kits for important information on
this item.
CMXA 51-IS
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
Specifications
•
•
•
•
•
Type: NiMH
Capacity: 1 800 mAh
Operating time: 8 hours
Charge time: 8 hours
Dimensions: 66 × 55 × 21 mm (2.60 × 2.17 × 0.83 in.)
Ordering information
Ordering information
CMAC 5090 Universal power supply, includes four plug adapters.
CMAC 5105 Battery.
64
CMXA 80
Battery
•
The CMAC 5090 universal power supply is
used for connecting the docking station to
the power cord. This power adapter delivers
power to the SKF Microlog while charging
the battery when inside the instrument. It
also features a connector to mate with the
USB / splitter cable (CMAC 5019) or the
docking station (CMAC 5068). Since this
universal power supply can support 100 to
240 V input, it also comes with USA, UK,
AUS and EURO adapter plugs.
• • • • • •
Universal power supply
(non-IS)
CMAC 5105
CMAC 5110
CMAC 5405
Strobe light power supply
CMXA 48
CMXA 75
Note: The CMAC 5110 power supply requires a
country-specific power cord.
CMXA 45
CMXA 70 / 44
CMXA 70-Z2
The CMAC 5405 universal power supply /
recharger supplies 115 or 230 V AC for use
with the CMSS 6165 strobe light. The power
supply also comes with both US and European adapter cables.
•
CMXA 51-IS
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
The CMAC 5110 power adapter charges and
powers the battery when connected to the
CMXA 51-IS unit; however, it should only be
used outside hazardous areas.
• • • •
CMXA 80
Power supply
CMXA 45
CMXA 51-IS
Specifications
• Voltage rating: 8,6 V
• Current rating: 0,6 A
• Cable length requirement: 1 m, ±50 mm
(3.3 ft., ±2 in.)
Ordering information
Ordering information
CMAC 5110 Power supply (IS).
CMAC 5405 Strobe light power supply, includes US and European
adapter cables.
65
66
Miscellaneous Accessories
Shoulder strap (CMXA 45, CMXA 70, CMXA 75), CMAC 5010 . . . . . . . . . . . . . . . . . . .
68
Shoulder strap (CMXA 48, CMXA 80), CMAC 5073. . . . . . . . . . . . . . . . . . . . . . . . . . . .
68
Shoulder strap, leather, hazardous areas, CMAC 5113 . . . . . . . . . . . . . . . . . . . . . . . .
69
Hand strap (CMXA 45, CMXA 70, CMXA 70-Z2, CMXA 75), CMAC 5020 . . . . . . . . . . .
69
Hand strap (CMXA 48, CMXA 80), CMAC 5072 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
70
Instrument soft cover (CMXA 45, CMXA 70, CMXA 75), CMAC 5024 . . . . . . . . . . . . . .
70
Soft case (CMXA 48, CMXA 80), CMAC 5071 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
71
Carrying pouch, leather, hazardous areas, CMAC 5111 . . . . . . . . . . . . . . . . . . . . . . .
71
Rubber boot, CMAC 5015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
72
Carrying case (location for printer), CMAC 5026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
72
Carrying case, hard shell (CMXA 45, CMXA 70, CMXA 70-Z2, CMXA 75), CMAC 5029 73
Carrying case, hard shell (CMXA 48, CMXA 80), CMAC 5069 . . . . . . . . . . . . . . . . . . .
73
Carrying case, hard shell (IS), CMAC 5118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
74
Fischer and audio connector cover set, CMAC 5075 . . . . . . . . . . . . . . . . . . . . . . . . . .
74
SDIO and dock connector cover, CMAC 5083 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
75
Docking station (CMXA 48, CMXA 80), CMAC 5068 . . . . . . . . . . . . . . . . . . . . . . . . . . .
75
Screen protector (CMXA 48, CMXA 80), CMAC 5074 . . . . . . . . . . . . . . . . . . . . . . . . . .
76
Screen protector (CMXA 45, CMXA 75), CMAC 6139 . . . . . . . . . . . . . . . . . . . . . . . . . .
76
Stylus (IS), CMAC 5251 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
77
Audio headset, hard hat compatible, CMAC 5403 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
77
67
CMAC 5073
CMAC 5010
Shoulder strap
CMXA 48
• •
This shoulder strap fastens directly to the
rubber boot (CMAC 5015) or to the instrument itself. The strap features a metal plate
to hold the sensor / magnet.
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
CMXA 51-IS
The CMAC 5073 shoulder strap is adjustable
and features a removable steel plate that
has been designed to hold a few transducers
(if fitted with a magnetic mount). This plate
is attached via two heavy-duty press studs
and can be removed if not required. The
strap also has a safety breakaway. The
breakaway strength is adjustable and may
be set to break easily or not so easily – to
user preference.
Ordering information
Ordering information
CMAC 5010 Shoulder strap.
CMAC 5073 Shoulder strap.
68
• •
CMXA 80
Shoulder strap
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
CMAC 5113
CMAC 5020
CMXA 80
Shoulder strap, leather,
hazardous areas
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
CMXA 48
The hand strap is provided in all kits and is
designed for easier and safer operations of
the instrument. It enables the operator to
hold onto the unit with one hand and still
press the keypad and fire buttons. The hand
strap fastens directly to the rubber boot or
instrument. It does not include a stylus,
although it is equipped with a stylus holder.
Ordering information
Ordering information
CMAC 5113 Shoulder strap, leather, hazardous areas.
CMAC 5020 Hand strap.
• • • • •
• • • • •
The CMAC 5113 shoulder strap is part of
the SKF Microlog’s ATEX certification; it may
be affixed to the SKF Microlog while in use
in a hazardous area.
CMXA 80
Hand strap
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
69
CMAC 5072
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 48
This protective carrying case is designed to
provide additional protection to the SKF
Microlog. This instrument cover is to be used
with the leather shoulder strap
(CMAC 5113), which is sold separately.
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
CMXA 51-IS
CMXA 45
CMXA 51-IS
Ordering information
Ordering information
CMAC 5072 Hand strap.
CMAC 5024 Instrument soft cover.
70
CMXA 80
Instrument soft cover
• •
The hand strap is provided in all kits and is
designed for easier and safer operations of
the instrument. It enables the operator to
hold onto the unit with one hand and still
press the keypad and fire buttons. The hand
strap fastens directly to the instrument.
• •
Hand strap
CMAC 5024
CMAC 5071
The CMAC 5071 soft case includes a plastic
protective sleeve and a pouch that snaps to
the back of the sleeve to hold cables, etc.
These two pieces are only sold together.
• •
Soft case
CMAC 5111
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
Carrying pouch, leather,
hazardous areas
CMXA 80
The CMAC 5111 carrying pouch is part of
the SKF Microlog’s ATEX certification; the
unit may be in the carrying pouch while in
use in a hazardous area.
CMXA 75
CMXA 48
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 45
•
CMXA 51-IS
Ordering information
Ordering information
CMAC 5071 Soft case, includes protective sleeve and pouch.
CMAC 5111 Carrying pouch, leather, hazardous areas.
CMXA 51-IS
71
CMAC 5015
CMAC 5026
CMXA 80
Rubber boot
CMXA 48
• Temperature range: –60 to +130 °C
(–76 to +266 °F)
• Material: Santoprene 8000 rubber
• Weight: 130 g (4.6 oz.)
• Dimensions: 20,0 × 12,5 cm (7.9 × 4.9 in.)
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 51-IS
The CMAC 5026 carrying / service case contains a location for the Pentax PocketJet
portable printer. The case includes foam
cutouts for the SKF Microlog unit, six accelerometers, a power supply and spare battery. The case also includes a pouch for the
power cord and cables, as well as an elastic
strap with a clip fastener used for holding
the manual / documentation. The black case
is made of double skinned ABS material,
weighs 1 kg (2.2 lb.) and has dimensions of
45 × 35 × 17 cm (17.7 × 13.8 × 6.7 in.).
Ordering information
Ordering information
CMAC 5015 Rubber boot.
CMAC 5026 Carrying case (location for printer).
72
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
•
Specifications
CMXA 75
CMXA 48
• •
Note: The CMAC 5015 is shipped with the SKF
Microlog CMXA 51-IS to meet the IECEx Mining
requirements for drops.
• • • • •
This protective rubber boot (sleeve) is
designed to provide additional protection to
the SKF Microlog. While it is made out of
heavy-duty rubber, the shoulder strap
(CMAC 5010) should also be purchased.
CMXA 80
Carrying case (location for
printer)
CMXA 45
CMXA 51-IS
CMAC 5069
CMAC 5029
Carrying case, hard shell
CMXA 48
• • • •
The CMAC 5029 hard carrying case includes
foam cutouts for the SKF Microlog, accelerometers and magnetic bases.
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
The CMAC 5069 hard carrying case includes
foam cutouts for the SKF Microlog, accelerometers and magnetic bases. When opened,
the cover includes a pouch for storing
cables.
• •
CMXA 80
Carrying case, hard shell
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 45
CMXA 51-IS
CMXA 51-IS
Ordering information
Ordering information
CMAC 5029 Carrying case, hard shell.
CMAC 5069 Carrying case.
73
CMAC 5118
CMAC 5075
CMXA 48
CMXA 75
The CMAC 5118 carrying case is utilized to
transport and store the SKF Microlog and its
accessories. However, it requires approval by
the site’s safety officer prior to entering a
hazardous area.
CMXA 70 / 44
Fischer and audio connector
cover set (3)
The CMAC 5075 kit consists of a set of three
Fisher connector covers, including two type
103 covers and one type 102 cover.
• • •
CMXA 80
Carrying case, hard shell (IS)
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 70-Z2
•
CMXA 45
•
CMXA 51-IS
CMXA 45
CMXA 51-IS
Ordering information
Ordering information
CMAC 5118 Carrying case, hard shell (IS).
CMAC 5075 Fischer and audio connector cover set (3).
74
CMXA 80
CMAC 5083
CMXA 80
Docking station
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
The CMAC 5068 docking station is used for
docking the SKF Microlog while supplying it
with power. This docking station requires the
CMAC 5090 universal power supply.
• •
The CMAC 5083 SDIO and dock connector
cover attaches to the bottom of the SKF
Microlog with two screws and a tether. The
cover protects the SD memory card slot and
docking station connectors in harsh environments.
• •
SDIO and dock connector
cover
CMAC 5068
CMXA 80
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 45
CMXA 45
CMXA 51-IS
CMXA 51-IS
Ordering information
Ordering information
CMAC 5083 SDIO and dock connector cover.
CMAC 5068 Docking station.
75
CMAC 5074
CMXA 80
CMXA 80
Screen protector
CMXA 48
CMXA 75
CMXA 70 / 44
CMXA 70-Z2
CMXA 48
The CMAC 6139 screen protector helps keep
the LCD plastic cover of the SKF Microlog
from scratching. CMAC 6139 includes a set
of five replacement screen protectors.
•
The CMAC 5074 screen protector helps keep
the LCD plastic cover of the SKF Microlog
from scratching. CMAC 5074 includes a set
of five non-glare, self-adhesive screen protectors.
• •
Screen protector
CMAC 6139
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 45
CMXA 51-IS
CMXA 45
CMXA 51-IS
Ordering information
Ordering information
CMAC 5074 Screen protector (includes five).
CMAC 6139 Screen protector, includes a set of five.
76
CMXA 75
CMAC 5251
CMAC 5403
CMXA 48
CMXA 75
The CMAC 5251 stylus for the SKF Microlog
is safe for use in hazardous areas; any other
kind of stylus would require approval from
the site’s safety officer.
CMXA 70 / 44
CMXA 70-Z2
•
CMXA 51-IS
CMXA 80
CMXA 48
CMXA 75
The CMAC 5403 audio headset connects to
the SKF Microlog and allows users to listen
CMXA 70 / 44
to the audio output as an aid to machinery
diagnostics. The headphones are high qualCMXA 70-Z2
ity and industrial grade. Special earpiece
cups reduce surrounding noise and are softCMXA 45
ly molded to provide comfort during extendCMXA 51-IS
ed wear. The adjustable fabric head strap
and neck band are designed for environments where a hard hat must be worn. The
audio connection includes a standard 3,5 mm (0.14 in.) jack plug.
•
CMXA 45
Audio headset, hard hat
compatible
• • •
CMXA 80
Stylus (IS)
Note: The CMAC 5078 audio headphone cable is required for use.
Ordering information
Ordering information
CMAC 5251 Stylus (IS).
CMAC 5403 Audio headset, hard hat compatible.
77
CMAC 4300
CMAC 4321
Accelerometer adapter for SKF Microlog / SKF Marlin, 1/4-28 stud
Cable, SKF Microlog / PC direct access
CMAC 4400
CMAC 4628
Lens savers for SKF Microlog (5)
Adapter, BNC to LEMO, for CMSS 6190L
CMAC 5004
CMAC 5017
Screen protector
Fischer connector cover set
CMAC 5022
CMAC 5211
Power supply (non-IS)
Strobe light kit for SKF Microlog Analyzer GX series (CMXA 70) and CMVA series
CMAC 5401-K
CMAC 5402
Audio headphone and strobe adapter kit
Audio headphone strobe adapter kit for SKF Microlog
CMSS 2100
CMSS 2100-K
General purpose, two-pin, industrial accelerometer, 100 mV/g (with 1/4-28 and M8 mounting stud)
Industrial accelerometer kit, includes CMSS 908-MD magnetic base and CMSS 60139-04 stinger
CMSS 31476402-CE
CMSS 31707500-CE
Cable, SKF Microlog to CMSS 786M
Cable, SKF Microlog to CMSS 2100 / 2106 / 2200 / 2206 / 787A / 793 / 786A (two pin MIL)
CMSS 376
CMSS 50077A-CE
High temperature accelerometer, charge mode, 260 °C (500 °F)
Cable, CMVA60 / CMVA 10 / CMVA 40 to support module, 120 cm (4 ft.)
CMSS 50080-CE
CMSS 50139/AUDIO
Cable, support module to PC, 120 cm (4 ft.)
Cable, SKF Microlog audio
CMSS 50156
CMSS 50157
Cable, CMVA 60 / CMVA 10 / CMVA 40 to BNC, with power, 150 cm (5 ft.)
Adapter, SKF Microlog to Microdot (10-32)
CMSS 50162-15
CMSS 50197-CE
Cable, SKF Microlog to BNC, with power, 450 cm (15 ft.)
Cable, SKF Microlog to CMSS 6186 / CMSS TMDT2 (CE compliant)
CMSS 50221
CMSS 50236
Cable, SKF Microlog to CMSS 793V
Standard SKF Microlog connection cable
CMSS 50238
CMSS 50247-2
Cable, SKF Microlog to modem
Cable, SKF Microlog to BNC (3), without diode, 1,5 m (5 ft.)
CMSS 50272-CE
CMSS 50278-CE
Cable, CMSS 793 to SKF Microlog, IS (CE compliant)
Cable, CMSS 6135E adapter to CMSS 6165 strobe light
CMSS 50280-CE
CMSS 50288
Cable, CMVA 65 video out
Cable, CMSS 50289 to CMSS 376
CMSS 50289
CMSS 60139-04
Charge amp SKF Microlog adapter
Probe tip, 11,43 cm (4.5 in.) stinger, 1/4-28 mounting
CMSS 6135E
CMSS 6145K-1
Phase adapter
Adapter, CMSS 6186 and accelerometer with CMSS 50236 cable
CMSS 6155K-U-CE
CMSS 6155VK-U-CE
Optical phase reference kit for use with CMVA 10 and CMVA 40
Optical phase reference kit for use with CMVA 55, CMVA 60 and CMVA 65
CMSS 6160
CMSS 6165-SPC
Printer adapter
Strobe light cover
CMSS 6165K-VA
CMSS 6187-CE
Strobe light kit for SKF Microlog CMVA series
Primary current clamp probe, 60 A / 600 A
CMSS 6190L
CMSS 6190L-K
Audio headphones with LEMO connector (not for use with CMVA 30)
Non-CMVA 60 Microlog audio headphones kit with LEMO connector (not for use with CMVA 30)
CMSS 6190L-K-W
CMSS 6195A-K
CMVA 60 Microlog audio headphones kit with LEMO connector
Laser phase reference kit (115 / 230 V), for use with CMVA 60 / CMVA 65
78
CMXA 44
Product
CMXA 70
Model number
CMVA Series
Accessories for obsolete products
••
• ••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
•
••
••
••
CMSS 786M
CMSS 793LK
Twin sensor, multi-parameter (acceleration / SEE)
Low frequency accelerometer kit
CMSS 793V
CMSS AD-BLANK
General purpose, industrial, two-pin velocity sensor
Stainless steel discs (10 discs per package, minimum order 10 packages)
CMSS R2-2-J5A-10
CMSS R6-2-J5A-10
Cable, BNC to trigger source, 300 cm (10 ft.)
Cable, BNC to CMSS 793, two-pin MIL, 300 cm (10 ft.)
CMSS T-5
CMSS TMDT2K
Reflective tape for optical and laser phase reference
Digital thermometer kit
CMVA 3351
CMVA 3355
Power cord, UL, 110 V, US
AC / DC adapter, universal, for CMVA 6112 only, does not include power cord
CMVA 3355-US
CMVA 50230-4
AC / DC adapter, universal, for CMVA 6112 only, includes CMSS 3351 power cord
Battery pack, NiMH, for CMVA 60, CMVA 10 and CMVA 40
CMVA 6112-CE
CMVA 6112-CE-RU
Support module, enhanced, replaces CMVA 6111 support module
Support module, enhanced, Russian
CMVA 6112K-CE
CMVA 6120-03-02
Support module kit, enhanced, replaces CMVA 6111K
SKF Microlog carrying case, black nylon, for use with CMVA 10 and CMVA 40
CMVA 6121
CMVA 6122
SKF Microlog hard carrying case, pelican, gray, for use with all Micrologs (foam not cut to shape)
SKF Microlog carrying case, clear plastic moisture protection, for use with all Micrologs
CMVA 6130
CMVA 6134-HD
SKF Microlog carrying case, black cotton
SKF Microlog hard shell carrying case with logo (foam cut to shape)
10873706
10873707
230 V AC fast recharger for use with strobe light
115 V AC fast recharger for use with strobe light
••
••
••
••
••
••
••
••
••
••
CMXA 44
Product
CMXA 70
Model number
CMVA Series
Accessories for obsolete products (continued)
•• ••
79
CMAC 5010
CMAC 5015
Shoulder strap
Rubber boot
CMAC 5019
CMAC 5020
USB communication / power splitter straight cable
Hand strap
CMAC 5023
CMAC 5024
Signal input straight cable
Instrument soft cover
CMAC 5026
CMAC 5029
Carrying case (location for printer)
Carrying case, hard shell
CMAC 5030K
CMAC 5031
Laser tachometer kit
Battery
CMAC 5032
CMAC 5036
Power / trigger splitter straight cable
CHX signal input straight extension cable, 5 m (16.4 ft.)
CMAC 5037
CMAC 5043
CHX signal input straight extension cable, 10 m (32.8 ft.)
Tachometer straight extension cable, 5 m (16.4 ft.)
CMAC 5044
CMAC 5056
Tachometer straight extension cable, 10 m (32.8 ft.)
Modal analysis hammer kit – for structures 210 g (7.6 oz.) and above
CMAC 5057
CMAC 5058
Modal analysis hammer kit – for structures 56 g (2 oz.) and above
Modal analysis hammer kit – without accelerometer
CMAC 5061
CMAC 5062
High frequency accelerometer straight cable
High frequency accelerometer straight cable
CMAC 5068
CMAC 5069
Docking station
Carrying case, hard shell
CMAC 5070
CMAC 5071
Battery
Soft case
CMAC 5072
CMAC 5073
Hand strap
Shoulder strap
CMAC 5074
CMAC 5075
Screen protector
Fischer and audio connector cover set
CMAC 5078
CMAC 5079
Audio headphone straight cable
Splitter, four channel straight cable
CMAC 5082
CMAC 5083
USB / A to B straight cable
SDIO and dock connector cover
CMAC 5084
CMAC 5087
ICP microphone with integral preamplifier kit
Temperature gun interface straight cable
CMAC 5088
CMAC 5090
Signal input straight cable
Universal power supply
CMAC 5105
CMAC 5110
Battery
Power supply
CMAC 5111
CMAC 5113
Carrying pouch, leather, hazardous areas
Shoulder strap, leather, hazardous areas
80
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
• ••
••
• •• •
•• •• •
••
• ••
••
• ••
• ••
•
• •
• •
• •
•
••
••
••
••
••
••
••
••
••
••
••
••
•
••
••
••
••
••
••
••
••
••
••
••
••
CMXA 51-IS
Triax accelerometer kit
Triaxial accelerometer coiled cable
••
••
CMXA 45
CMAC 4370-K
CMAC 5009
CMXA 70-Z2
Cable converter, two pin MIL to BNC
Infrared thermometer
CMXA 70 / 44
CMAC 3715
CMAC 4200-K-SL
CMXA 75
Product
CMXA 48
Model number
CMXA 80
Product index
Page
33
42
8
26
68
72
34
69
34
70
72
73
44
62
35
31
32
32
33
45
45
45
••
26
27
75
73
63
71
70
68
•
•
•
•
76
74
35
27
36
75
••
••
••
•• •
••
••
••
• • • • ••
48
36
37
64
64
65
71
69
CMAC 5201
CMAC 5208
Serial communication cable
AC / DC current clamp
CMAC 5209
CMAC 5209-06S
Accelerometer coiled cable, 1,8 m (6 ft.)
Accelerometer coiled cable with safety breakaway
CMAC 5209-10
CMAC 5211
Accelerometer coiled cable, 3 m (10 ft.)
BNC tachometer straight cable
CMAC 5213
CMAC 5214
Laser tachometer kit straight cable, 24 cm (9.5 in.)
Laser tachometer kit straight cable, 2 m (6.56 ft.)
CMAC 5251
CMAC 5403
Stylus (IS)
Audio headset, hard hat compatible
CMAC 5404
CMAC 5405
Strobe light input straight cable
Strobe light power supply
CMAC 5406
CMAC 6139
Strobe light output straight cable
Screen protector
CMCP 850-01
CMCP 850-02
Microlog Analyzer field balancing accessory kit with optical sensor
Microlog Analyzer field balancing accessory kit with laser sensor
CMCP 850-03
CMSS 2111
Microlog Analyzer field balancing accessory kit with laser sensor
Small footprint accelerometer with integral cable
CMSS 2114-K
CMSS 2200
High frequency accelerometer kit
General purpose, low profile, side exit industrial accelerometer
CMSS 2200-M8
CMSS 2210
General purpose, low profile, side exit industrial accelerometer with M8 studs
Intrinsically safe (IS) industrial accelerometer
CMSS 6155XK-U-CE Optical phase reference kit
CMSS 6156
Optical phase reference magnetic holder
CMSS 6165K-AX
CMSS 6195AX-K
Strobe light kit
Smart laser sensor tachometer
CMSS 732A
CMSS 793-CA
Small diameter accelerometer
CSA approved, general purpose industrial accelerometer
CMSS 793-EE
CMSS 908-MD
ATEX approved, intrinsically safe, general purpose industrial accelerometer
Medium duty magnetic base
•
••
••
••
•
••
•
••
••
••
•
••
••
••
•
••
••
••
•
••
•
••
••
••
•
••
••
••
•
••
••
••
•
••
••
••
••
••
•
••
••
••
•
•• ••
•• •
••
••
•
••
••
••
• •
••
••
••
• • • • ••
CMXA 51-IS
Trigger coiled cable
Carrying case, hard shell (IS)
CMXA 45
CMAC 5117
CMAC 5118
CMXA 70-Z2
ATEX certified accelerometer coiled cable
AC / DC signal coiled cable
CMXA 70 / 44
CMAC 5115
CMAC 5116
CMXA 75
Product
CMXA 48
Model number
CMXA 80
Product index (continued)
••
••
• •
••
••
••
• •
••
••
••
••
••
• •
•
••
••
• ••
Page
28
37
38
74
38
49
28
29
29
30
30
31
77
77
39
65
39
76
51
51
51
10
11
13
13
15
52
55
56
59
16
18
20
22
81
SKF – the knowledge engineering
company
From the company that invented the selfaligning ball bearing more than 100 years
ago, SKF has evolved into a knowledge
engineering company that is able to draw on
five technology platforms to create unique
solutions for its customers. These platforms
include bearings, bearing units and seals, of
course, but extend to other areas including:
lubricants and lubrication systems, critical
for long bearing life in many applications;
mechatronics that combine mechanical and
electronics knowledge into systems for more
effective linear motion and sensorized solutions; and a full range of services, from design and logistics support to conditioning
monitoring and reliability systems.
Though the scope has broadened, SKF
continues to maintain the world’s leadership
in the design, manufacture and marketing of
rolling bearings, as well as complementary
products such as radial seals. SKF also holds
an increasingly important position in the
market for linear motion products, highprecision aerospace bearings, machine tool
spindles and plant maintenance services.
The SKF Group is globally certified to ISO
14001, the international standard for environmental management, as well as OHSAS
18001, the health and safety management
standard. Individual divisions have been
approved for quality certification in accordance with ISO 9001 and other customer
specific requirements.
With over 100 manufacturing sites worldwide and sales companies in 70 countries,
SKF is a truly international corporation. In
addition, our distributors and dealers in
some 15 000 locations around the world,
an e-business marketplace and a global
distribution system put SKF close to customers for the supply of both products and
services. In essence, SKF solutions are available wherever and whenever customers
need them. Overall, the SKF brand and the
corporation are stronger than ever. As the
knowledge engineering company, we stand
ready to serve you with world-class product
competencies, intellectual resources, and
the vision to help you succeed.
© Airbus – photo: exm company, H. Goussé
Evolving by-wire technology
SKF has a unique expertise in fast-growing bywire technology, from fly-by-wire, to drive-bywire, to work-by-wire. SKF pioneered practical flyby-wire technology and is a close working partner
with all aerospace industry leaders. As an example,
virtually all aircraft of the Airbus design use SKF
by-wire systems for cockpit flight control.
SKF is also a leader in automotive by-wire technology, and has partnered with automotive engineers to develop two concept cars, which employ
SKF mechatronics for steering and braking. Further by-wire development has led SKF to produce
an all-electric forklift truck, which uses mechatronics rather than hydraulics for all controls.
Seals
Bearings
and units
Mechatronics
82
Lubrication
systems
Services
Harnessing wind power
The growing industry of wind-generated electric power provides a source of
clean, green electricity. SKF is working closely with global industry leaders to
develop efficient and trouble-free turbines, providing a wide range of large,
highly specialized bearings and condition monitoring systems to extend equipment life of wind farms located in even the most remote and inhospitable
environments.
Working in extreme environments
In frigid winters, especially in northern countries, extreme sub-zero temperatures can cause bearings in railway axleboxes to seize due to lubrication starvation. SKF created a new family of synthetic lubricants formulated to retain
their lubrication viscosity even at these extreme temperatures. SKF knowledge
enables manufacturers and end user customers to overcome the performance
issues resulting from extreme temperatures, whether hot or cold. For example,
SKF products are at work in diverse environments such as baking ovens and
instant freezing in food processing plants.
Developing a cleaner cleaner
The electric motor and its bearings are the heart of many household appliances. SKF works closely with appliance manufacturers to improve their products’ performance, cut costs, reduce weight, and reduce energy consumption.
A recent example of this cooperation is a new generation of vacuum cleaners
with substantially more suction. SKF knowledge in the area of small bearing
technology is also applied to manufacturers of power tools and office
equipment.
Maintaining a 350 km/h R&D lab
In addition to SKF’s renowned research and development facilities in Europe
and the United States, Formula One car racing provides a unique environment
for SKF to push the limits of bearing technology. For over 50 years, SKF products, engineering and knowledge have helped make Scuderia Ferrari a formidable force in F1 racing. (The average racing Ferrari utilizes more than 150 SKF
components.) Lessons learned here are applied to the products we provide to
automakers and the aftermarket worldwide.
Delivering Asset Efficiency Optimization
Through SKF Reliability Systems, SKF provides a comprehensive range of
asset efficiency products and services, from condition monitoring hardware
and software to maintenance strategies, engineering assistance and machine
reliability programmes. To optimize efficiency and boost productivity, some
industrial facilities opt for an Integrated Maintenance Solution, in which SKF
delivers all services under one fixed-fee, performance-based contract.
Planning for sustainable growth
By their very nature, bearings make a positive contribution to the natural
environment, enabling machinery to operate more efficiently, consume less
power, and require less lubrication. By raising the performance bar for our
own products, SKF is enabling a new generation of high-efficiency products
and equipment. With an eye to the future and the world we will leave to our
children, the SKF Group policy on environment, health and safety, as well as
the manufacturing techniques, are planned and implemented to help protect
and preserve the earth’s limited natural resources. We remain committed to
sustainable, environmentally responsible growth.
83
Please contact:
SKF Reliability Systems
SKF Condition Monitoring Center – San Diego
5271 Viewridge Court • San Diego, California 92123 USA
Tel: +1 858-496-3400 • Fax: +1 858-496-3531
Web Site: www.skf.com/cm
® SKF and MICROLOG are registered trademarks of the SKF Group.
ICP is a registered trademark of PCB Group, Inc.
Loctite is a registered trademark of Henkel Corporation
All other trademarks are the property of their respective owners.
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication, but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. SKF
reserves the right to alter any part of this publication without prior notice.
SKF Patents include: #US04768380 • #US05679900 • #US05845230 • #US05854553 • #US05992237 • #US06006164 •
#US06199422 • #US06202491 • #US06275781 • #US06489884 • #US06513386 • #US06633822 • #US6,789,025 •
#US6,792,360 • US 5,633,811 • US 5,870,699 • #WO_03_048714A1
PUB CM2412 EN · October 2010
skf.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project