PAG RMC4X Charger
DATA SHEET
PAG RMC4X Charger
RACK-MOUNTABLE SIMULTANEOUS CHARGER
2 charger units can
be mounted sideby-side in a full 19”
rack system
A single unit fits into
a half-rack system
• Ideal for use in outside broadcast vehicles
• Designed to be mounted in 19” rack systems
• 4-channel, simultaneous, Li-Ion and Ni-MH battery charger
• Includes four V-Mount or four PAGlok battery charging connectors
• High-powered 100W output (6A at 16.8V)
DESCRIPTION
The PAG RMC4X is a rack-mountable version of PAG’s highpower, simultaneous Cube charger.
The RMC4X-V is ideal for use in outside broadcast vehicles,
but it is equally suitable for use in a workshop environment.
It can be used to simultaneously fast-charge Li-Ion batteries
manufactured by PAG or Sony, via four V-Mount battery
connectors. The battery mounts connect to the charger via
four XLR4 connectors.
A bespoke mounting-board for the connectors, that enables
them to be fitted vertically inside the OB vehicle, can also be
supplied.
The charger is designed to be mounted in a half-width racking
system, and measures 1U high. Two units can be mounted
side by side in a standard full-width 19-inch rack, by using
connecting plates, available from PAG.
The backlit LCD screen clearly indicates each stage of the
charging process.
The charger incorporates a Li-Ion recovery feature.
S P E C I F I C AT I O N
Range of Batteries Charged:
PAG RMC4X-V (V-Mount)
Model No. 9702VR:
• PAG V-Mount Lithium-Ion batteries
• Sony V-Mount Lithium-Ion batteries
• PAG V-Mount Nickel-Metal Hydride batteries
• Sony V-Mount Nickel-Metal Hydride
batteries
Nickel-Metal Hydride batteries are charged
sequentially.
Self Test Program:
The internal microcomputer constantly
monitors the battery under charge or process
as well as the operation of the charger’s own
functions which will be shut down to a safe
condition should any of the tests fail.
Mains Input:
90V to 265V AC. Frequency 50-60 Hz.
EN6100-3-2 Power factor corrected. Maximum
consumption 140W.
Output Protection:
Charger protected against short circuit and
excess battery voltage.
PAG RMC4X-P (PAGlok)
Model No. 9702R:
• PAGlok Lithium-Ion batteries.
• PAGlok Nickel-Metal Hydride batteries
• PAGlok Nickel-Cadmium batteries
PAGlok Li-Ion batteries having more than two
terminals are charged simultaneously. All
other PAGlok Li-Ion batteries are charged
sequentially. All PAGlok Ni-MH and Ni-Cd
batteries are charged sequentially.
Battery Connections:
Model 9702VR: 4 x V-Mount connectors.
Model 9702R:
4 x PAGlok connectors.
Main Charge Program:
• Li-Ion Intelligent Parallel Charging program.
• Maximum output 6A at 16.8V (100W
approx.).
Recovery Charge Program:
This special program will automatically
recover a Li-Ion battery where the output has
been shut down. Additionally, the program
detects batteries having a very low voltage,
and initiates a special low charge current.
The program will operate until the voltage has
risen sufficiently for batteries to safely accept
the normal charge current.
AC Mains Failure Protection:
Should mains failure occur during a charging
program, or whilst the charger is connected, it
will shut down to a safe condition.
User Interface:
Comprehensive Liquid Crystal Display
showing status of battery and charger. The
charger is fully automatic in operation and no
user controls are provided.
Overall Dimensions (Excluding Charging
Connectors):
Height: 44mm
Width: 210mm
Depth: 201mm
Weight (Excluding Charging Connectors):
1.8kg
Typical Battery Charging Times:
Batteries:
Charge Time:
1 x PAG L96
3hrs 15mins
2 x PAG L96
4hrs
3 x PAG L96
5hrs
4 x PAG L96
6hrs 30mins
These times are approximate only, and
assume batteries are fully discharged.
Charging times will be less if batteries are
already partially charged.
Safety:
Designed to comply with electrical safety
standard BS EN 60065 and UL6500. NOTE:
U.K. mains leads are fitted with a 1" fuse to
BS1362 rated 5A as standard.
European Union Directives:
Complies with the following EU Directives:
EMC Directive 89/336/EU.
Low Voltage Directive 73/23/EU.
Operating Temperature Range:
0°C to +40°C (+32°F to +104°F).
PAG Ltd.
565 Kingston Road
London SW20 8SA
United Kingdom
E [email protected]
T +44 (0)20 8543 3131
F +44 (0)20 8540 4116
www.paguk.com
© NOV 2014 PAG Ltd. PAG is the trademark of PAG Ltd.
PAG reserves the right to change the specifications
contained herein without notice