DOUBLE CONVERSION ON-LINE UPS
FROM 10 kVA TO 50 kVA
WIDE VOLTAGE INPUT
IGBT INVERTER & OUTPUT
ISOLATION TRANSFORMER
THREE PHASE IN
SINGLE PHASE OUT
HIGH RELIABILITY
DSP CONTROL
DIRECT CURRENT COLD
START FUNCTION
FULL PROTECTION FUNCTION
INTELLIGENT RS232 / RS485
COMMUNICATION PORT
SNMP ADAPTER*
ADVANCE N+1 PARALLEL
TECHNOLOGY*
INTELLIGENT BATTERY
MONITORING SYSTEM - MMBM*
Product Code
Application : Data Centre; Hospital Critical Equipment
Telecommunication Industry & Others
The UK2000 series is a Double Conversion
On-line UPS system that has built-in automatic
voltage regulation, power surge protection and
lightning surge suppression. The UPS system
provides critical equipments with continuous
clean power supply when there is irregular
voltage, brownouts or power failure.
This state of the art conventional UPS
is not only affordable, but is built with
paralleled for N+1 redundancy. It also
comes built-in Isolated Transformer with
low harmonics distortion; narrow output
voltage tolerance, Long Back-up time
with external battery bank and many
more useful features.
SPECIFICATION
INPUT
MODEL
UK2015
UK2020
380 / 400 ± 25%
Frequency (Hz)
50 / 60 ± 5%
Phase
15/10.5
20/16
40/32
220V / 230V ± 1%
Frequency (Hz)
50 / 60 ± 0.5% (battery mode)
Waveform
Voltage (VDC)
Battery Type
125% load for 60 seconds
125% load for 60 seconds; 150% load for 20 seconds
16 x 12V = 192
29 x 12V = 348
32x7Ah 12V /
48x7Ah 12V /
External
External
Maintenance Bypass
Switch
External
3/5
10~20 setting
Optional
Standard
Communication Interface
RS232/RS485, dry connector (MODBUS and SNMP adapter are optional)
LCD display indicates frequency, voltage, load capacity, battery voltage, etc. LED indicates running status
Alarm
Low battery, abnormal AC input, overload, UPS failure
Protection
Low battery, overload, output over temperature, short circuit, over temperature
Noise (dB)
< 60
0 ~ 95%, No condensation
Relative Humidity
Dimension (mm) WxDxH 400 x 800 x 1180
Standard / Long Backup / 300 x 740 x 700
Standard / Long Backup
< 65
0 ~ 40ºC
Working Temperature
Weight (Kg)
50/40
0
Charger Current(A) Max
Display
UK2050
Pure Sine Wave, THD < 3% (Linear Load)
Transfer Time
BATTERY
30/24
Voltage (VAC)
Overload
UK2040
Three Phase In Single Phase Out (L1, L2, L3, N, G)
10/7
150% load for 1 second
OTHERS
UK2030
Voltage (VAC)
Capacity (kVA/KW)
OUTPUT
UK2010
250 / 130
400 x 800 x 1180
320 / 195
205
** Specification is subject to change without prior notice.
For parallel system, Maintenance Bypass Switch is not available.
2011 JST Power Solutions Sdn Bhd. All Rights Reserved.
All other brand names and trade marks are property of the respective owners.
225
273
304
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement