Sinus LCD Series On-Line “Double Conversion” Technology 1 phase in-1 phase out 1kVA to 3kVA (Tower & Rack Convertible) On-line ‘double conversion’ technology Real Digital Signal Processor (DSP) Controller Power factor correction PFC (>0,99) User friendly LCD display Programmable Receptacles Wide input voltage range and frequency Availability to configure as 50/60Hz Frequency Converter from LCD Panel Smart communication port and SNMP management capability Hot Swappable Battery Emergency shutdown control through EPO Overload & short circuit protection Cold start (DC power on) Genius battery management (GBM) RS232, USB and SNMP can be activated simultaneously Compact size, light weight & low noise Sinus LCD Series Technical Specifications MODEL Power(kVA) INPUT Voltage Frequency Power Factor OUTPUT Power Factor Voltage Voltage Regulation Frequency Frequency Regulation Harmonic Distortion Crest Factor Output Waveform SS LCD 210 1 SS LCD 220 2 160VAC - 288VAC 50/60 Hz ± 5% (Auto Sensing) >99% 0,8 220VAC / 230 / 240VAC ±%1 50/60 Hz ± 0,1% <3% 3:1 Sinusoidal 100%-120% for 30 seconds 120%-150% for 10seconds Overload Capacity Whole efficiency Transfer Time Outlets BATTERY Type Recharge Time Voltage Internal Battery Back Up Time SS LCD 230 3 >85% 3 pcs IEC C13 or 1pc Schuko Cold Start DISPLAY LED Display LCD Display ALARMS 4pcs IEC C13 or 2pcs Schuko Maintenance-free lead acid batteries 3 hours (to 90% of full capacity) 72VDC 6pcs 12V 7Ah 36VDC 3pcs 12V 7Ah Full Load Half Load >88% 0ms 3 pcs IEC C13 or 2pcs Schuko 5 min 12 min 6pcs 12V 9Ah 4 min 10 min YES Utility or Bypass, Battery Low, Battery Abnormal, Overload, Site Wiring Fault, Service Mode, UPS Off, UPS Abnormal Input /Output Voltage and Frequency Values, Load%, Battery Voltage, Internal Temperature Line Failure, Battery Low, Over Load, Failure Events PROTECTIONS Short circuit, over temperature, overload, high voltage, battery low, EPO COMMUNICATION Interface ENVIRONMENT Temparature Humidity Noise Level(1m distance) Protection Class PHYSICAL Net Weight (kg) Dimensions (mm) WxDxH (Rack) RS232 and USB 0°C - 40°C 0% - 90% (without condensation) <50dBA (at 1 meter) IP 20 16 440x450x88 29,5 440x650x88 30 440x650x88 STANDARDS EN 62040-1-1 (safety), EN 62040-2(EMC) ACCESORIES L E INT RTIFICAT I ON NA CE RNAT IO Internal&External SNMP, Dry Contact Board, External Manual Bypass, Rail Kit, Software S
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement