Below you will find brief information for environment meter SD-9300. The SD-9300 is a multi-function instrument that can measure air velocity, temperature, humidity, light levels, and even sound levels (with an optional adapter). It features a real-time SD memory card datalogger, auto power off, data hold, and the ability to record maximum and minimum readings. The device is powered by six 1.5V batteries.
Advertisement
Advertisement
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Rich Black -
20/20/20/100
Model
SD-9300
Environment Meter/
Datalogger
Instruction
Manual
reedinstruments
www.reedinstruments.com
www
1-877-849-2127 | [email protected]
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Table of Contents
Features ............................................................................................ 3
Specifications ................................................................................3-5
Instrument Description ..................................................................... 6
Operating Instructions .................................................................7-12
Function selection .......................................................................... 7
Air velocity/Temperature measurement .......................................... 7
Changing the Air velocity unit ......................................................... 7
Humidity/Temperature measurement ............................................. 8
Type K/J Thermometer measurement ............................................ 8
Light Meter measurement .............................................................. 8
Changing the Light Meter unit ........................................................ 8
Zero Adjustment ............................................................................ 9
Sound Level measurement ............................................................ 9
Data Hold ...................................................................................... 9
Data Record .............................................................................9-10
Backlight ON/OFF ........................................................................ 10
Datalogger ................................................................................... 10
Auto Datalogger ......................................................................10-11
Manual Datalogger ....................................................................... 11
Checking the Time ....................................................................... 11
Check Sampling Time Information ................................................ 11
SD Card Data Structure ............................................................... 12
Data Transfer from SD card to Computer ..................................... 12
Advanced Settings ....................................................................13-15
Set Clock Time ............................................................................ 13
Setting the Decimal point on the SD Card .................................... 14
Auto power OFF management ..................................................... 14
Set Beeper Sound ON/OFF ......................................................... 14
Select the Thermometer to Type K or Type J ............................... 14
Select the Temperature unit to °C or °F ........................................ 15
Set sampling time ........................................................................ 15
SD memory card Format ............................................................. 15
Blue - 100/80/30/5
Yellow - 0/27/100/0
PC Serial Interface .......................................................................... 16
System Reset ................................................................................. 17
Yellow - 0/27/100/0
Battery Replacement ...................................................................... 17
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
2
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Features
• Meter functions as a Type K/J Thermometer, Humidity/Temperature
Meter, Anemometer, Light Meter, and a Sound Level Meter (with the optional adapter)
• Humidity measurements shown in both %RH and Temp
• Anemometer can default the display unit to m/S, FPM, Km/h, mph, knot
• Light meter can display LUX or Ft-cd
• Real time SD memory card datalogger with a built-in clock and calendar
• Meter can switch to a Manual Datalogging
• No extra software needed, just plug the SD card into the computer and it downloads directly to EXCEL
• SD card capacity: 1 GB to 16 GB
• Easy to read LCD with backlight
• Auto power off or manual power off
• Data hold, record max. and min. reading
• Power by UM3/AA (1.5 V) x 6 batteries
• USB/RS232 Computer interface
Pantone 534 Blue
Pantone 123 Yellow
Specifications
Circuit:
Display:
Auto Sampling Time:
Memory Card:
Sampling Time:
Data Output:
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Resolution:
Blue - 100/80/30/5
Black
Custom microprocessor LSI circuit
52mm x 38mm LCD with backlight
1, 2, 5, 10, 30, 60, 120, 300, 600, 1800,
3600 seconds
SD memory card, 1 GB to 16 GB
Approx. 1 second
USB/RS232 PC computer interface
0-50°C (0-122°F)
0.1°C/0.1°F reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
3
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Accuracy: ± 0.8°C/1.5°F
Operating Temperature: 0-50°C (0-122°F)
Operating Humidity:
Power Supply:
Less than 85% R.H.
UM3/AA (1.5 V) x 6 batteries
Weight:
Dimensions:
Includes:
Optional accessories:
515g/1.13lb
Main instrument: 135 x 60 x 33mm
Probe: 105 x 46 x 29mm
Multi-function Probe, hard carrying case,
& batteries
4G SD Card (SD-4GB)
Type K thermocouple probe (TP-01)
Sound Adapter (SL-417)
USB cable (USB-01)
Power adapter (AP-9VA-110V)
Data Acquisition Software (SW-U801-WIN)
Tripod (BS-6)
Visit us at www.reedinstruments.com for more information on our Optional
Accessories, or e-mail us at [email protected]
Air velocity
Measurement Range m/S 0.4-30.0m/S
Km/h
Mph
1.4-126.0Km/h
0.9-78.3mph
Resolution
0.1m/S
0.1Km/h
0.1mph
Knots
FPM
0.8-68.0 knots 0.1 Knots
79-6890 FPM 1 FPM
Accuracy
±(2%+0.2 m/S)
±(2%+0.8 Km/h)
±(2%+0.4 mph)
±(2%+0.4 Knots)
±(2%+40 FPM)
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Air Temperature
Measuring Range: 0 to 50°C (32 to 122°F)
Yellow - 0/27/100/0
Resolution:
Accuracy:
0.1
±0.8°C (±1.5°F)
Blue - 100/80/30/5
Pantone 534 Blue
Black reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
continued...
4
INSTRUMENTS
Humidity
Measuring Range:
Resolution:
Accuracy:
Light meter
Measuring Range:
Resolution:
Accuracy:
0% to 95%RH
0.1%RH
70%RH: ±(3% reading + 1% RH);
< 70% RH: ± 3% RH
0-20,000 LUX, 0-1,860 Ft-cd
1 LUX, 0.1 Ft-cd
±(5% rdg ± 8 dgt)
Type K/J thermometer
Sensor Type Resolution
Type K
Type J
0.1°C
0.1°F
0.1°C
0.1°F
Range
-50.0 to 1300.0°C
-50.1 to -100.0°C
-58.0 to 2372.0°F
-58.1 to -148.0°F
-50.0 to 1200.0°C
-50.1 to -100.0°C
-58.0 to 2192.0°F
-58.1 to -148.0°F
Accuracy
± (0.4% + 0.5°C)
± (0.4% + 1°C)
± (0.4% + 1°F)
± (0.4% + 1.8°F)
± (0.4% + 0.5°C)
± (0.4% + 1°C)
± (0.4% + 1°F)
± (0.4 % + 1.8°F)
Above specification tests under the environment RF Field Strength less than 3 V/M & frequency less than 30 MHz only
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
For service on this or any other REED product or information on other
Yellow - 0/27/100/0
REED products, contact REED Instruments at [email protected]
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
5
INSTRUMENTS
Instrument Description
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
1. Display
2. Power, ESC, & Backlight Button
3. Hold, Function, & Next Button
4. REC, Enter, & Unit Button
5. SET, Down, & Time Check Button
6. Logger, Up, & Sampling Time
Check Button
7. Probe input socket
8. Type K/J thermometer socket
10. USB/RS232 Output
Red - 10/100/100/5
11. Reset Button
12. AC/DC 9V Power Adapter
Input Socket
13. Battery Compartment/Cover
14. Battery Cover Screws
15. Stand
16. Tripod Fix Nut
17. Probe Head
18. Anemometer vane
19. Humidity/Temperature Sensor
20. Light Sensor
21. Probe Plug
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
6
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Operating Instructions
Function selection
1) Turn on the meter by pressing the Power Button. To turn the meter, hold the Power Button for over 2 seconds.
2) The meter has 4 measuring functions to choose from: Air velocity/Temp, Humidity/Temp, Type K/J Thermometer, or Light Meter measurements. When the meter is on, press and hold the Function
Button. The display will flash “An”, for Air velocity/Temperature measurement, “rH” for Humidity/Temperature measurement, “tP” for Type K/J Thermometer measurement, and “LIgHt” for Light measurements. Release the Function Button to choose the displayed function.
Air velocity/Temperature measurement
1) Select the “An” function (see Function Select).
2) When the meter is off, plug the Probe Plug into the Probe Input
Socket, then power on the meter by pressing the Power Button.
3) Hold the Probe Handle and face the Anemometer Head against the measuring airflow source. The top part of the Display will show the air velocity, and the lower part of the Display will show the air temperature value.
Changing the Air velocity unit
To change the Air velocity unit, press and hold the Unit Button, while in the Air Measuring Function. The display will flash the units m/S, Km/h, mph, Knot, & FPM. Release the Unit Button to select the displayed unit.
The selected unit will be saved as the default.
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
7
Humidity/Temperature measurement
1) Select the “rH” function (see Function Select)
2) When the meter is off, plug the Probe Plug into the Probe Input
Socket, then power on the meter by pressing the Power Button.
3) The top part of the Display will show the %RH value, and the lower part of the Display will show the temperature value.
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Type K/J Thermometer measurement
1) Select the “tP” function (see Function Select).
2) Plug the optional Type K or J Thermocouple Probe into the Type
K/J Probe Input Socket. Be sure the Air Velocity Probe is not plugged in.
3) The screen will display a “K”, meaning it is configured for a Type
K thermometer probe. The measured temperature will now be displayed on the display screen. To change the meter to accept a Type
J Probe, please see the Advanced Settings section.
Light Meter measurement
1) Select the “LIgHt” function (see Function Select).
2) When the meter is off, plug the Probe Plug into the Probe Input
Socket, then power on the meter by pressing the Power Button.
3) Hold the Probe Handle and face the Light Sensor against the measuring light source. The top part of the Display will show the light measurement value.
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Changing the Light Meter unit
To change the Light Meter unit, press and hold the Unit Button, while in the Light Meter Function. The display will flash the units LUX and Ft-cd.
Release the Unit Button to select the displayed unit. The selected unit will
Yellow - 0/27/100/0 be saved as the default.
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
8
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Zero Adjustment
While taking a Light Measurement, completely cover the light sensor. If the Display does not show value of zero, press and hold the Logger Button until the Display shows a zero value.
Sound Level measurement (optional probe required)
1) Power off the meter.
2) Plug the optional Sound Adapter Plug into the Probe Input Socket and power on the Sound Adapter (for detailed operation procedures, please refer to its operation manual).
3) Power on the meter by pressing the Power Button. The meter’s
Display will show the symbol “Sound”, then return to the normal measuring screen with the Display Unit dB. Now the meter is ready to take sound level measurements. The display will show the measuring sound value with unit “dB”.
Data Hold
While taking a measurement, press the Hold Button once and the measured value will hold on the screen, and a HOLD symbol will appear.
Press the Hold Button once again will release the data hold function.
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Data Record (Max., Min. reading)
The data record function records the maximum and minimum readings.
Press the REC Button once to start the Data Record function and a “REC” symbol will appear on the display. With the “REC” symbol on the display:
1) Press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. To delete the maximum value, press the Hold Button once and the display will show a “REC.” symbol only and execute the memory function continuously.
Blue - 100/80/30/5
Yellow - 0/27/100/0
2) Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display. Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
continued...
reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
9
INSTRUMENTS
To delete the minimum value, press the Hold Button once, and the display will show a “REC.” symbol only and execute the memory function continuously.
3) To exit the memory record function, press the REC button for 2 seconds. The display will revert to the current reading.
Backlight ON/OFF
After powering the meter ON, the LCD Backlight will turn on automatically. While taking measurements, press the Backlight Button and the LCD
Backlight will turn off. Press the Backlight Button once again to turn the
LCD Backlight back ON.
Datalogger
Preparation Before Executing the Datalogger Function:
1) Insert the optional SD card into the SD card socket.
2) Before you use an SD card with this meter for the first time, it is recommend to format the SD card. See Advanced Settings section of this manual for instructions.
3) If this is the first time the meter is used you need to adjust the clock. See Advanced Settings section of this manual for instructions.
4) Now you need to set the decimal format. The numerical data structure downloaded to the SD card is defaulted used the “.” as the decimal, for example “20.6” “1000.53”. But in certain countries the
“,” is used as the decimal point, for example “20,6” “1000,53”. See
Advanced Settings section of this manual for instructions on how to change the Decimal Character.
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Auto Datalogger (Set sampling time ≥1 second)
1) Start Datalogging; press the REC Button, and the “REC” symbol
Blue - 100/80/30/5 will appear on the LCD screen, then press the Logger Button, the
“REC” symbol will flash while the measuring data and time informa-
Yellow - 0/27/100/0 tion is being saved in memory.
Blue - 100/80/30/5
continued...
reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
10
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
To set the sampling time, and to toggle the beeper sound on or off, refer to the Advanced Settings section of this manual.
2) Pause the Datalogging; while Datalogging, if press the Logger Button once. While paused, the “REC” symbol will stop flashing. Press the Logger Button again to resume Datalogging, and the “REC” symbol will begin to flash again.
3) Stop Datalogging; while the Datalogger function is paused, press the REC Button for 2 seconds. The “REC” symbol will disappear indicating the Datalogging function has stopped.
Manual Datalogger (Set sampling time = 0 seconds)
1) Set sampling time is to 0 second; Press the REC Button, and the
“REC” symbol will appear on the LCD screen. Press the Logger
Button, and the “REC” symbol will flash once and one Beep will sound, at the same time the measuring data along the time information will be saved in memory. The lower Display will show the
Position (record) number, which is saved as well.
2) To Change the Position Number; press the Down Button and the lower position number will flash on the display. Press the Up or
Down Buttons to set the Position Number (1 to 99) to help identify the measurement location. The lower Display will show P x (x = 1 to
99). After the position number is selected, press the Enter Button to confirm.
3) Stop Datalogging; press the REC Button for 2 seconds, and the
“REC” symbol will disappear indicating the Datalogging function has stopped.
Checking the Time
During normal functions (not Datalogging), press the Time Check Button and the lower LCD display will show the Year, Month/Date, Hour/Minute.
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Blue - 100/80/30/5
Check Sampling Time Information
During normal functions (not Datalogging), press the Sampling Button and the lower LCD display will show the Sampling Time Information.
Blue - 100/80/30/5
Pantone 534 Blue
Black reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
11
SD Card Data Structure
1) The first time the SD card is used in the meter, the SD card will generate a folder: EMA01
2) The first time you use the Datalogger, in the folder EMA01, a new file name EMA01001.XLS will be created. The Datalogger will use this file until the Data has reached to 30,000 rows. The meter will then will generate a new file with a subsequent number, for example EMA01002.XLS.
3) The folder EMA01can hold 99.XLS files. When that number has been reached, the meter will then will generate a new folder with a subsequent number, for example EMA02. Max number of EMA-- folders is 10.
Data Transfer from SD card to Computer (EXCEL Software)
1) After Datalogging, remove the SD card from the SD card slot.
2) Plug in the SD card into the Computer’s SD card slot or insert the
SD card into the optional SD card adapter and connect to your
Computer. Turn your computer on and a folder will appear on your desktop representing you SD card.
3) Open “Microsoft EXCEL”. Download the EXCEL files from the SD
Card to the computer by opening up the SD folder and selecting the desired EXCEL files, and drag-and-drop them onto your Computer. Open the files with EXCEL (File – Open).
4) The EXCEL file will have the following column headers in this order:
Place (Position Number), Date (Year/Month/Day), Time (in 24h clock), Value, and Unit.
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
12
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Advanced Settings
During normal functions (not Datalogging), press and hold the SET Button for 2 seconds to enter the “Advanced Setting” mode. Press the Next Button scroll through eight main functions, shown on the lower display:
dAtE Set clock time (Year/Month/Date, Hour/Minute/Second)
dEC Set SD card Decimal character
PoFF Auto power OFF management
bEEP Set beeper sound ON/OFF
tYPE Select the Thermometer to Type K or Type J
t-CF Select the temperature unit to °C or °F
SP-t Set sampling time (Hour/Minute/Second)
Sd F SD memory card Format
While in the “Advanced Setting” function, press the Esc Button to exit and to return to normal functioning.
Set Clock Time
1) When the lower display shows “dAtE”, press the Enter Button.
Use the Up and Down Buttons to adjust the Year. After the desired value is set, press the Enter Button to adjust the Month, Date, Hour,
Minute, and Second values.
2) After all the time values have been set the screen will jump to “SD card Decimal character” setting screen. To exit “Advanced Settings”, press the Esc Button.
Note: After the time value is set, the internal clock will run even when the power is off, if the battery is under normal conditions.
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
13
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Setting the Decimal point on the SD Card
1) When the lower display shows “dEC”, use the Up or Down Buttons to toggle between “bASIC” (“.” Decimal Point) or “Euro” (“,” Decimal Point).
2) After the Decimal point character has been selected, press the
Enter Button to save the setting as the default. To exit “Advanced
Settings”, press the Esc Button.
Auto power OFF management
1) When the lower display shows “PoFF”, use the Up or Down Buttons to select the value “yES” (Enable Auto Power Off) or “no”
(Disable Auto Power Off.
2) After selecting “yES” or “no”, press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc
Button.
Set Beeper Sound ON/OFF
1) When the lower display shows “bEEP”, use the Up or Down Buttons to select “yES” (Beeper Sound is ON) or “no” (Beeper Sound is OFF).
2) After selecting “yES” or “no”, press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc
Button.
Pantone 534 Blue
Pantone 123 Yellow
Select the Thermometer to Type K or Type J
1) When the lower display shows “tYPE”, use the Up or Down Buttons to select “K” (for Type K Thermometer) or “J” (for Type J Thermometer).
2) After selecting “K” or “J”, press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc Button.
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Blue - 100/80/30/5
Black reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
14
Select the Temperature unit to °C or °F
1) When the lower display shows “t-CF”, use the Up or Down Buttons to select “C” (for °C) or “F” (for °F).
2) After selecting “C” or “F”, press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc
Button.
Set sampling time
1) When the lower display shows “SP-t”, use the Up or Down Buttons to adjust the value to either 0, 1, 2, 5, 10, 30,60, 120, 300, 600,
1800, or 3600 seconds.
2) After the Sampling value is selected, press the press the Enter Button to save the setting as the default. To exit “Advanced Settings”, press the Esc Button.
SD memory card Format
Please Note: Formatting the SD card erases all data from that SD card.
1) When the lower display shows “Sd F”, use the Up or Down Buttons to select “yES” (format the SD card) or “no” (do not format the SD card).
2) To format your SD card, select “yES” and press the Enter Button.
The Display will show “yES Enter”, to confirm. Press the Enter Button to confirm.
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
15
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
PC Serial Interface
The instrument features an PC output via 3.5 mm terminal. The connector output is a 16 digit data stream which can be utilized to the user’s specific application. An USB RS232 lead with the following connection will be required to link the instrument with the PC serial input.
Meter (3.5mm Jack Plug) PC (9W “D” Connector)
Center Pin Pin 2
Ground/Shield Pin 5
The 16 digit data stream will be displayed in the following format:
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
D10
D11
D12
D13
D14
D15
D0 End Word
D1 to D4 Upper Display reading, D1= LSD, D4= MSB
D5 to D8 D5=? D6=? D7=? D8=?
D9 Decimal Point ( DP) for display
0 = No DP, 1 = 1 DP, 2 = 2 DP, 3 = 3 DP
D10 = 0
D11 = 0
D12 = 0
D13 = 0
D14 = 0
Start Word
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
16
System Reset
If an error occurs, press the Reset Button with a Pin. If the Reset Button does not fix the error, please send in the unit to our Calibration Lab for repair. E-mail [email protected] for more information.
Battery Replacement
1) When the left corner of LCD display shows , it is necessary to replace the battery
2) Loosen the screws of the Battery Cover and remove
3) Remove the batteries and replace with Six DC 1.5 V batteries
(UM3, AA, Alkaline/heavy duty)
4) Make sure the battery cover is properly secured after changing the battery
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
For service on this or any other REED product or information on other
Red - 10/100/100/5
REED products, contact REED Instruments at [email protected]
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
17
INSTRUMENTS
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
18
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
19
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Blue - 100/80/30/5 reedinstruments com
www.reedinstruments.com
Only if you REALLY need them:
INSTRUMENTS
20
Advertisement
Key features
- Measures air velocity, temperature, humidity, light, sound (with optional adapter)
- Real-time SD memory card datalogger
- Auto power off
- Data hold
- Record maximum and minimum readings