Installation instructions for your new

Electric Dryer

Before you begin - Read these instructions completely and carefully.

IMPORTANT - Save these instructions for local inspector’s use.

IMPORTANT - OBSERVE ALL GOVERNING CODES AND ORDINANCES.

Note to Installer - Be sure to leave these instructions with the Consumer.

Note to Consumer - Keep these instructions with your Owner’s Manual for future reference.

31

Note: Installation of this dryer requires basic mechanical and electrical skills.

It is your responsibility to contact a qualified electrical installer to make the electrical connection.

WARNING – POTENTIAL FIRE AND SHOCK HAZARD

Use only rigid or flexible metal 100 mm (4

) diameter ductwork for exhausting to the outdoors. Never use plastic or other combustible ductwork.

This appliance must be properly grounded (earthed) and installed as described in these instructions and governing codes.

Do not install or store appliance in an area where it will be exposed to water/weather.

Important

Exhausting the dryer to the outdoors is strongly recommended to prevent large amounts of moisture and lint from being blown into the room.

Before the old dryer is removed from service or discarded, remove the door to the drying compartment.

Service information and wiring diagram are located in control console.

Tools and Materials you will need

Slip joint pliers

Screwdrivers (slotted or Phillips head)

One 3/4

″ recognized strain relief

4 inch dia. rigid metal duct, elbows and exhaust hood.

Basic safety protection such as safety goggles, gloves, and arm protection is recommended.

Installation

Step 1

Remove and save literature and parts package from dryer drum.

Step 2

Pull here to separate from front leg

Lay carton corner posts or two boards on floor. Lay dryer on its back.

Dryer legs

Step 3

Foam shipping pads

Pull here to separate from rear leg

Remove foam shipping pads by pulling at sides and breaking away from dryer legs.

Be sure to remove all foam pieces from around legs.

Step 4

Stand dryer upright.

Step 5

Move dryer to desired operating location.

Step 6

Adjust leveling legs to match washer height. Dryer must be level and rest firmly on all four leveling legs.

Step 7

Connect to power supply.

(See ELECTRICAL CONNECTION INFORMATION section of this instruction.)

Step 8

Connect external exhaust or deflector. (See EXHAUST

INFORMATION section of this instruction.)

Step 9

Check for proper operation.

Step 10

Place Owner’s Manual and installation instructions in a location where they may be found by the customer.

500A187P031 49-90048

02-00 JR

31-16027

1

Electrical Connection Information

WARNING:

TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK, OR PERSONAL INJURY

DO NOT USE AN EXTENSION CORD

WITH THIS APPLIANCE.

THIS APPLIANCE MUST BE PROPERLY

GROUNDED (EARTHED).

Dryer must be electrically grounded (earthed) in accordance with local codes and ordinances.

Electrical requirements:

The operating voltage (volts), amperage (amps) or wattage (watts) and frequency (Hz) of your dryer are indicated on the rating plate located on the upper right corner of the door opening.

The dryer must be connected to an individual branch circuit corresponding to that indicated on the rating plate and protected by the required time-delay fuses or circuit breakers in accordance with governing codes.

If the electrical supply does not meet what is indicated on the rating plate, call a licensed electrician.

IF THE DRYER IS SUPPLIED WITH A FLEXIBLE POWER CORD

Plug the cordset into its own separate grounded outlet. DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR

REMOVE THE GROUND PRONG FROM THE POWER CORD.

IF THE DRYER IS SUPPLIED WITH A TERMINAL BLOCK

ASSURE GROUND (EARTH) WIRE

IS PROPERLY CONNECTED

BROWN

MAKE SURE SCREWS ARE

PROPERLY TIGHTENED

STRAIN RELIEF

BRACKET

POWER SUPPLY CORD

220/240 VAC 30A

BLUE

USE PROPER

STRAIN RELIEF

WIRING DIAGRAM AND SOME SERVICE INFORMATION LOCATED IN CONTROL HOUSING

1.

Remove cover near the power supply entry hole.

2.

Install 3/4 inch, recognized strain relief to power entry hole. Bring power supply through strain relief.

3.

Connect power supply as follows:

A.

Live (brown) line to upper screw of terminal block

(marked L1).

B.

Neutral (blue) line to center screw of terminal block

(marked N).

4.

Attach ground (earth) wire (green, green and yellow, or bare) to the green ground screw (hole above strain relief bracket). Tighten all terminal block screws firmly.

5.

Properly secure power supply to strain relief.

6.

Reinstall the cover.

WARNING: NEVER LEAVE THE TERMINAL BLOCK WITHOUT THE COVER.

2

Exhaust Information

WARNING:

TO REDUCE THE RISK OF FIRE

AND PERSONAL INJURY

Use only metal duct for exhausting dryer to outdoors.

Do not terminate exhaust in a chimney, any gas vent, under an enclosed floor (crawl space), or into an attic.

The accumulated lint could create a fire hazard.

Provide an access for inspection and cleaning of the exhaust system, especially at turns. Inspect and clean at least once per year.

Never terminate the exhaust into a common duct with a kitchen exhaust. A combination of lint and grease could create a fire hazard.

Do not obstruct incoming or exhausted air.

Rear Exhaust Location

This dryer comes ready for rear exhausting. If space is limited, use the following instructions to exhaust directly from the side or bottom of the cabinet.

Exhaust Length

The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct, number of turns, type of exhaust hood (wall cap) and all conditions noted below. The maximum allowable length for both rigid and flexible metal duct is shown in the table below. More than two 90° turns are not recommended.

FOR ELECTRIC

DRYER ONLY

RECOMMENDED MAXIMUM LENGTH

Weather Hood Type

Recommended Use only for short run installations

Screw inside duct

90 mm (3 1 ⁄

2

)

NOTE: Add to vertical dimension the distance between cabinet bottom and floor surface.

298 mm (11 3 ⁄

4

)

Steps to Change Dryer to Side or Bottom Exhaust

Directly on Cabinet

WARNING: Protect your hands and arms from sharp edges when working inside the dryer cabinet.

1.

Detach and remove the desired knockout.

2.

Remove the screw inside the dryer exhaust duct end. Keep the screw for step 5. Pull on the duct to remove it.

B

Fixing hole

3.

Cut the duct as shown. Keep portion A.

A

229 mm (9

)

4.

Through the rear opening, locate the tab in the middle of the dryer base. Lift the tab to about 45° using a flat screwdriver.

Only metal duct may be used inside the dryer cabinet

Blower housing

229 mm (9

)

Cut portion

A

Base tab location

(under duct)

216 mm

(8 1 ⁄

2

)

285 mm

(11 1 ⁄

4

)

Back of side panel

121 mm (4 3 ⁄

4

) 121 mm (4 3 ⁄

4

)

5.

Reconnect and secure the cut portion (A) of the duct to the blower housing. Make sure the fixing hole is aligned with the tab in the base. Use the screw from step 2 to secure the duct in place through the tab on the dryer base.

6.

Use standard metal elbows and duct to complete the exhaust system. Insert standard elbows and ducts through rear and side or bottom openings.

7.

Cover the opening at the back with the plate (Kit

WE1M454) available from your local service provider.

WARNING: NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE.

3

Number of

90° elbows

0

1

2

Rigid

10 cm (4

) 6 cm (2 1 /

2

)

Flexible Rigid Flexible

Metal Metal

10.7m (35 ft) 7.6m (25 ft) 7.6m (25 ft) 4.0m (13 ft)

9.1m (30 ft) 4.6m (15 ft) 4.6m (15 ft) 3.0m (10 ft)

6.1m (20 ft) 3.0m (10 ft) 3.0m (10 ft)

Do not use non-metallic flexible duct.

Hood or Wall Cap

Terminate in a manner to prevent back drafts or entry of birds or other wildlife.

Termination should present minimal resistance to the exhaust airflow and should require little or no maintenance to prevent clogging.

Never install screen over exhaust duct.

Wall caps must be installed at least 300 mm (12

) above ground level or any other obstruction with the opening pointed down.

If roof vents or louvered plenums are used, they must be equivalent to a 100 mm (4

) dampered wall cap in regard to resistance to airflow, prevention of back drafts and maintenance required to prevent clogging.

Separation of Turns

For best performance, separate all turns by at least 1.2 m

(4

) of straight duct, including distance between last turn and dampered wall cap.

Turns Other Than 90°

One turn of 45° or less may be ignored.

Two 45° turns should be treated as one 90°.

Each turn over 45° should be treated as one 90°.

Sealing of Joints

All joints should be tight to avoid leaks. The male end of each section of duct must point away from the dryer.

Do not assemble the duct work with fasteners that extend into the duct. They will serve as a collection point for lint.

Duct joints can be made air- and moisture-tight by wrapping the overlapped joints with duct tape.

Exhaust Information (cont.)

Insulation

Ductwork which runs through an unheated area or is near an air-conditioning duct should be insulated to reduce condensation and lint buildup.

Parts Available From Local Service Organization

Rigid Metal Duct Components

WX8X64

WX8X51

WX8X88

100 mm (4

) x 60 cm (2

) Duct

100 mm (4

) Elbow

100 mm (4

) Aluminum Hood

WE25X28 Exhaust Deflector

Flexible Metal Duct Components

Kit WX8X75 2.1 m (7

) Aluminum Flexible Duct

100 mm (4

) Clamps (2)

100 mm (4

) Aluminum Hood

Inside Exhausting

BEDROOM, BATHROOM, ALCOVE, OR CLOSET INSTALLATIONS

MUST BE EXHAUSTED TO THE OUTDOORS.

EXHAUSTING TO THE OUTDOORS IS STRONGLY RECOMMENDED.

EXHAUSTING INDOORS MAY CAUSE

LINT ACCUMULATION AND MOISTURE DAMAGE

INCLUDING MOLD AND MILDEW.

600 mm (24

) RIGID

OR FLEXIBLE DUCT

If the installation makes it impossible to exhaust to the outdoors, a 100 mm (4

) exhaust deflector (WE25X28) and 600 mm (2

′) rigid metal duct (WX8X64) must be installed over exhaust duct. A clearance of 200 mm (8

) is required between rear of dryer and the wall, and the deflector should be pointing up.

EXHAUST DEFLECTOR

(WE25X28)

Special Installation Requirements

Alcove or Closet Installation

If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back.

The dryer must be exhausted to the outdoors.

Minimum clearances between dryer cabinet and adjacent walls or other combustible surfaces are:

0 mm clearance on either side

80 mm (3

) front and rear

Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 1.3 m (52

).

Closet doors must be louvered or otherwise ventilated and must contain at least 400 cm 2 (60 square inches) open area equally distributed. If this closet contains both a washer and a dryer, doors must contain 800 cm 2 (120 square inches) of open space equally distributed.

SERVICING:

CAUTION:

Consideration must be given to provide adequate clearances for installation and servicing.

Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation

(verify proper operation after servicing/installation).

4