www.janitza.com Item no. 33.03.207 Doc. no. 1.040.129.0.e Power Analyser Janitza electronics GmbH Vor dem Polstück 6 D-35633 Lahnau Support tel. +49 6441 9642-22 Fax +49 6441 9642-30 E-mail: [email protected] Internet: http://www.janitza.com UMG 96 RM-E Residual current monitoring (RCM) User manual and technical data Power Analyser UMG 96RM-E Content General4 Inspection on receipt 6 Scope of delivery – UMG 96RM-E (RCM) 7 Product description 8 Proper use 8 Performance characteristics – UMG 96RM-E 10 Measuring process 11 Operating concept 11 GridVis network analysis software 11 Connection variants 12 Mounting13 Installation15 Power supply 15 Measuring voltage 16 Current measurement via I1 to I4 22 Residual current measurement (RCM) via I5, I631 Temperature measurement input 33 RS485 interface 34 Ethernet interface 37 Digital in-/outputs 38 LED status bar 43 Operation44 Display mode 44 Programming mode 44 Parameters and measured values 46 2 Configuration48 Connecting the supply voltage 48 Current and voltage transformers 48 Programming the current transformer for I1 to I350 Programming the voltage transformer 51 Programming parameters 52 TCP/IP configuration 53 RS485 device address (Addr. 000) 56 RS485 baud rate (Addr. 001) 56 MODBUS gateway (Addr. 002) 57 User password (Addr. 050) 57 Parameter58 Mean value 58 Averaging method 58 Min. and max. values 58 Mains frequency (Addr. 034) 59 Energy meter 60 Reset energy meter (Addr. 507) 60 Harmonics61 Measured value rotation 62 Measured value indocations 62 Phase sequence 64 LCD contrast (Addr. 035) 64 Backlight64 Time recording 65 UMG 96RM-E Operating hours meter 66 Serial number (Addr. 754) 66 “Drag indicator” 67 Recordings68 Putting into service 69 Connecting the supply voltage 69 Applying the measuring-circuit voltage 69 Applying the measuring-circuit current 69 Phase sequence 70 Check phase assignment 70 Checking the energy measurement 70 Applying the residual current 70 Failure monitoring (RCM) for I5, I6 71 Checking the measurement 73 Checking the individual outputs 73 Checking the total power outputs 73 RS485 interface 74 Digital outputs 76 Impulse output 78 Service and maintenance 84 Service84 Device calibration 84 Calibration intervals 84 Firmware update 85 Battery85 Battery monitoring function 86 Replacing the battery Error/warning messages Technical data Function parameters Table 1 – Parameter list Table 2 - Modbus address list Number formats Dimension diagrams Measured value displays overview Connection example 1 Connection example 2 Basic functions quick guide TCP/IP addressing quick guide 87 88 94 102 104 108 111 112 114 120 121 122 123 3 UMG 96RM-E General Comments on the operating manual Copyright We welcome your comments. In the event that anything in this operating manual seems unclear, please let us know and send us an EMAIL to: [email protected] This operating manual is subject to the legal requirements for copyright protection and may not be, either in whole or in part, photocopied, reprinted, or reproduced by mechanical or electronic means, or in any other manner be duplicated or redistributed without the legally binding, written agreement of Janitza electronics GmbH, Vor dem Polstück 1, D 35633 Lahnau, Germany. Trademarks All trademarks and their resulting rights belong to the respective holders of these rights. Disclaimer Janitza electronics GmbH takes no responsibility for errors or defects within this operating manual and takes no responsibility for keeping the contents of this operating manual up to date. Meaning of the symbols The following pictograms are used in the operating manual at hand: c m C 4 Dangerous voltage! Danger to life or risk of serious injury. Disconnect system and device from power supply before beginning work. Caution! Please follow the documentation. This symbol warns of possible dangers that can arise during installation, commissioning and use. Note! UMG 96RM-E Instructions for use Please read the operating manual at hand as well as all other publications that must be drawn from for working with this product (in particular for the installation, operation or maintenance). Follow all safety regulations and warning information. If you do not follow the information, it can result in bodily injury and/or damage to the product. Any unauthorized changes or use of this device, which transcend the mechanical, electrical or otherwise stated operating limitations, can result in bodily injury or/and damage to the product. Any of such unauthorized changes constitute "misuse" and/or "negligence" in terms of the warranty for the product and therefore eliminates the warranty for covering any potential damage resulting from this. This device is to be operated and maintained exclusively by specialized personnel. Specialized personnel are persons, that based on their respective training and experience, are qualified to recognize risks and prevent potential dangers that can be caused by the operation or maintenance of the device. Additional legal and safety regulations required for the respective application are to be following during the use of the device. c m m If the device is not operated according to the operating manual, protection is no longer ensured and danger can come from the device. Conductors made from single wires must be fitted with wire-end ferrules. Only pluggable screw terminals with the same number of poles and the same type of construction are permitted to be connected together. 5 UMG 96RM-E Concerning these operating instructions Inspection on receipt These operating instructions are a part of the product. • Read the operating instructions before using the device. • Keep the operating instructions throughout the entire service life of the product and have them readily available for reference. • Pass the operating instructions on to each subsequent owner or user of the product. The prerequisites of faultless, safe operation of this device are proper transport and proper storage, setup and assembly, as well as careful operation and maintenance. If it can be assumed that risk-free operation is no longer possible, the unit must be immediately put out of operation and secured against being put back into operation again. The packing and unpacking must be carried out with the customary care without the use of force and only using suitable tools. The devices should be visually checked for flawless mechanical condition. It can be assumed that risk-free operation is no longer possible if the device, for example, C 6 All screw-type terminals included in delivery are attached to the device. • has visible damage • no longer works despite the mains power supply being intact • has been exposed to long-term adverse conditions (e.g. storage outside the permissible climate limits without being adapted to the room climate, condensation etc.) or rough handling during transportation (e.g. fall from a height, even if there is no visible external damage etc.) • Please check the delivered items for completeness before you start installing the device. UMG 96RM-E Available accessories Number 2 1 1 1 1 1 1 1 1 1 1 1 1 1 Part no. 52.22.251 10.01.855 10.01.849 10.01.871 10.01.875 10.01.865 10.01.857 10.01.859 08.01.505 52.00.008 21.01.058 29.01.065 15.06.015 15.06.025 Description Mounting clips Screw-type terminal, pluggable, 2-pole (auxiliary power) Screw-type terminal, pluggable, 4-pole (voltage measurement) Screw-type terminal, pluggable, 6-pole (current measurement I1-I3) Screw-type terminal, pluggable, 2-pole (current measurement I4) Screw-type terminal, pluggable, 10-pole (digital/analogue inputs/outputs) Screw-type terminal, pluggable, 2-pole (RS 485) Screw-type terminal, pluggable, 3-pole (Digital/impulse output) Patch cable 2m, coiled, grey (connection UMG 96RM-PC/Switch) RS485, external terminating resistor, 120 ohm Lithium battery CR2032, 3V (approval i.a.w. UL 1642) Silicone seal, 96 x 96 Interface converter RS485 <-> RS232 Interface converter RS485 <-> USB 7 UMG 96RM-E Product description Proper use The UMG 96RM-E is intended for the measurement and calculation of electrical parameters such as voltage, current, power, energy, harmonics etc. in building installations, on distribution units, circuit breakers and busbar trunking systems. The UMG 96RM-E is suitable for integration into fixed and weatherproof switch panels. Conductive switch panels must be earthed. Measured voltage and measured current must derive from the same network. The measurement results can be displayed and can be read out and further processed via the RS485 interface. The voltage measurement inputs are designed for measurements in low voltage networks, in which rated voltages of up to 300V relative to earth and surges in overvoltage category III can occur. The current measurement inputs I1–I4 of the UMG 96RME are connected via external ../1A or ../5A current transformers. 8 By continuously monitoring the residual currents (RCM) of an electrical system via the inputs I5 and I6, warning pulses can be triggered if a response threshold is exceeded. Using these, the system operator can be alarmed before a protective equipment reacts. The UMG 96RM-E does not provide protection against and electric shock! The residual current measuring is done via the current measurement inputs I5 and I6 via an external residual current transformer with a rated current of 30 mA. Measurements in medium and high-voltage networks is always done via current and voltage transformers. m The residual current measuring monitors residual currents via external current transformers and can trigger a warning impule when a response threshold is exceeded. Thus, the device is NOT an independent protective device! UMG 96RM-E The UMG 96RM-E can be used in industrial and domestic settings. Device characteristics • Supply voltage: Option 230V: 90V - 277V (50/60Hz) or DC 90V - 250V; 300V CATIII Option 24V: 24 - 90V AC / DC; 150V CATIII • Frequency range: 45 - 65Hz Device functions • 3 voltage measurements, 300V • 4 current measurements (via current transformers ../5A or ../1A) • 2 residual current measurements (via residual current transformers ../30mA) or optionally 2 temperature measurements • RS485 interface, Ethernet • 2 digital outputs and additional 3 digital inputs/outputs • Clock and memory function 9 UMG 96RM-E Performance characteristics – UMG 96RM-E General • Front panel integration device with dimensions 96x96 mm. • Connection via pluggable screw terminals • LCD display with backlighting • Operation via 2 buttons • 3 voltage and 4 current measurement inputs • Optional 2 residual current or temperature measurement inputs • 2 digital outputs and 3 digital inputs/outputs • RS485 interface (Modbus RTU, slave, up to 115 kbps) • Ethernet (web server) • 256 MB flash memory (200 MB available for records) • Clock and bettery (with battery monitoring function) • Working temperature range -10°C .. +55°C Uncertainty in measurement • Active energy uncertainty in measurement class 0.5 for ../5A transformer • Active energy uncertainty in measurement class 1 for ../1A transformer • Reactive energy, class 2 10 Measurement • Measurement in IT, TN and TT networks • Measurement in networks with nominal voltage up to L-L 480V and L-N 277V • Measuring range current 0 to 5A eff. • True RMS (TRMS) • Continuous sampling of the voltage and current measurement inputs • Continuous monitoring of residual currents with failure monitoring • Temperature measurement • Frequency range of the fundamental oscillation 45Hz .. 65Hz • Measurements of the harmonic components 1st to 40th for ULN and I • Uln, I, P (reference/del.), Q (ind./cap.) • Collection of well over 1000 measured values • Fourier analyses 1st to 40th harmonic component for U and I • 7 energy counters for active energy (reference), active energy (supply), active energy (without return barrier), reactive energy (ind.), reactive energy (cap.), reactive energy (without return barrier), apparent energy, each for L1, L2, L3 and total UMG 96RM-E Measuring process GridVis network analysis software The UMG 96RM-E measures continuously and calculates all effective values over a 10/12 period interval. The UMG 96RM-E measures the real effective value (TRMS) of the voltage and current connected to the measurement inputs. The UMG 96RM-E can be programmed and read out using the GridVis network analysis software included in the scope of deliverables. For this a PC must be connected to the UMG 96RM-E via a serial interface (RS485) or via Ethernet. Operating concept GridVis features You can program and call up the measured values via many routes using the UMG 96RM-E. • Programming the UMG 96RM-E • Graphical representation of measured values • Directly on the device via 2 buttons. • Using the GridVis programming software. • Through the device's home page. • Using the Modbus protocol. You can modify and call up the data using the Modbus address list. The list can be called up via the device's home page and can be found on the enclosed CD. This manual only describes how to operate the UMG 96RM-E using the two buttons. The GridVis programming software has its own online help system. 11 UMG 96RM-E Connection variants Connection of a UMG 96RM-E to a PC via a interface converter: UMG 96RM-E Direct connection of a UMG 96RM-E to a PC via Ethernet. (gedrehtes Patchkabel) (Twisted patch cable) UMG 96RM-E UMG 96RM-E (gedrehtes Patchkabel) Connection of a UMG 96RM via a UMG 96RM-E as a gateway. UMG 96RM-E UMG 96RM UMG 96RM (gedrehtes Patchkabel) (gedrehtes Patchkabel) 12 Connecting a UMG 96RM-E to a PC via Ethernet. UMG 96RM-E Switch UMG 96RM-E Mounting Position of installation The UMG 96RM-E is suitable for integration into fixed and weatherproof switch panels. Conductive switch panels must be earthed. Mounting position To ensure adequate ventilation, the UMG 96RM-E must be installed vertically. There should be separation above and below of at least 50mm with 20mm space to the sides. Front panel section Cut-out size: 92+0.8 x 92+0.8 mm. Fig. mounting position UMG 96RM-E (View from rear) m Failure to meet the minimum clearances can destroy the UMG 96RM-E at high ambient temperatures! 13 UMG 96RM-E Mounting The UMG 96RM-E is fixed using the mounting clips found on the side of the switch panel. Before inserting the device, they should be moved out of the way in a horizontal lever using a screwdriver, for example. Fig. side view UMG 96RM-E with mounting clips. Loosening the clips is done using a screwdriver and a horizontal lever effect. The fastening is then done when the device is pushed in an the clamps lock in place when the screws are tightened. • Please tight the fixing screws until they contact the mounting plate easily. • Tighten with two further turns, the clamping screws (are the screws tightened too much, the mounting bracket will be destroyed) Mounting plate Fixing screw Mounting clips Screwdriver Contacting of the fixing screws to the mounting plate: Tighten with maximum two further turns for the installation 14 UMG 96RM-E Installation Power supply The 96RM-E needs a supply voltage to operate. The supply voltage is connected on the rear of the device via terminal blocks. Before connecting the supply voltage, ensure that the voltage and frequency correspond to the details on the ratings plate! The supply voltage must be connected through a UL/ IEC approved fuse (6A Char. B). m • If installed in a building, a disconnector or circuit-breaker must be provided for the supply voltage. • The disconnector must be installed near the device and easily accessible to the user. • The switch must be marked as the circuit breaker for this device. • Voltages which are over the permitted voltage range can destroy the device. L N Fuse Circuit breaker Fig. connection example of the supply voltage to a UMG 96RM 15 UMG 96RM-E Measuring voltage You can use the UMG 96RM-E to measure voltage in TN-, TT-, and IT systems. The voltage measurement in the UMG 96RM-E is designed for the overvoltage category 300V CAT III (rated impulse voltage 4 kV). L1 277V/480V 50/60Hz L1 L2 L1 240V 50/60Hz L3 In systems without N, the measurements which require an N are to a calculated N. 480V 50/60Hz L2 L3 N N PE Impedance V1 V2 V3 VN V2 V1 V3 VN Measuring voltage UMG 96RM Auxiliary energy Fig. schematic diagram - measurements in three-phase 4-wire systems. 16 4M 4M System earthing 4M DC AC/DC 4M 4M 4M 4M 4M AC/DC DC Measuring voltage UMG 96RM Auxiliary power Fig. schematic diagram - measurements in three-phase 3-wire systems. UMG 96RM-E Network nominal voltage Lists of networks and their nominal network voltages in which the UMG 96RM-E can be used. Three-phase, 4-wire systems with earthed neutral conductor. Three-phase, 3-wire systems, unearthed. UL-N / UL-L UL-L 66V / 115V 120V / 208V 127V / 220V 220V / 380V 230V / 400V 240V / 415V 260V / 440V 277V / 480V 66V 120V 127V 220V 230V 240V 260V 277V 347V 380V 400V 415V 440V 480V Maximum system nominal voltage Fig. table for network nominal voltages i.a.w. EN60664-1:2003 suitable for the voltage measurement inputs. Maximum system nominal voltage Fig. table for network nominal voltages i.a.w. EN60664-1:2003 suitable for the voltage measurement inputs. 17 UMG 96RM-E Voltage measurement inputs The UMG 96RM-E has three voltage measurement inputs (V1, V2, V3). L1 L2 Surge voltage The voltage measurement inputs are suitable for use in networks where overvoltages of overvoltage category 300V CATIII (rated impulse voltage 4kV) can occur. Frequency For the measurement and calculation of measured values, the UMG 96RM-E needs the network frequency. The UMG 96RM-E is suitable for measurements on systems in a frequency range from 45 to 65Hz. L3 N Fuse Circuit breaker Fig. Example connection for measuring voltage 18 UMG 96RM-E When connecting the voltage to be measured, the following must be observed: Isolation device • A suitable circuit breaker must be fitted to disconnect and de-energise the UMG 96RM-E. • The circuit breaker must be placed in the vicinity of the UMG 96RM-E, be marked for the user and easily accessible. • The circuit breaker must be UL/IEC certified. Overcurrent protection device • An overcurrent protection device must be used for line protection. • For line protection, we recommend an overcurrent protection device as per the technical specifications. • The overcurrent protection device must be suitable for the line cross section used. • The overcurrent protection device must be UL/IEC certified. • A circuit breaker can be used as an isolating and line protection device. The circuit breaker must be UL/IEC certified. • Measured voltages and measured currents must derive from the same network. c c c Caution! Voltages which exceed the permitted networkrated voltage must be connected via a voltage transformer. Caution! The UMG 96RM-E is not suitable for measuring DC voltages. Caution! The voltage measurement inputs on the UMG 96RM-E are dangerous if touched! 19 UMG 96RM-E Wiring diagrams, voltage measurement • 3p 4w (Addr. 509= 0), factory setting • 3p 4wu (Addr. 509 = 1) L1 L1 L2 L2 L3 N L3 N V1 V2 V3 Fig. System with three and neutral conductor. VN line V1 conductors • 3p 4u (Addr. 509 = 2) L1 L2 L3 L3 V3 VN Fig. System with three line conductors without neutral conductor. Measurements which require a N are based on a calculated N. 20 VN • 3p 2u (Addr. 509 = 5) L2 V2 V3 Fig. System with three line conductors and neutral conductor. Measurement using a voltage transformer. L1 V1 V2 V1 V2 V3 VN Fig. System with three line conductors without neutral conductor. Measurement using a voltage transformer. Measurements which require a N are based on a calculated N. UMG 96RM-E • 1p 2w1 (Addr. 509 = 4) • 2p 4w (Addr. 509 = 3) L1 L1 L2 L3 N N V1 V2 V3 V1 VN Fig. The values obtained from the voltage measurement inputs V2 and V3 are taken to be null and not calculated. • 1p 2w (Addr. 509 = 6) V2 V3 VN Fig. System with uniform phase loading. The measured values for the voltage measurement input V2 are calculated. • 3p 1w (Addr. 509 = 7) L1 L1 L2 L3 L2 L1 L2 L3 V1 V2 V3 VN Fig. TN-C system with single-phase three-wire connection. The null is taken from the voltage measurement input V3's measured value and not calculated. L1 L2 L3 N V1 V2 V3 VN Fig. 3 systems with uniform phase loading. The not connected measured values L2/L3, L1/ L3, and L1/L2 of each system are calculated. 21 UMG 96RM-E Current measurement via I1 to I4 The UMG 96 RM-E is designed to have current transformers with secondary currents from ../1A and ../5A attached cia terminals I1-I4. The factory default for the current transformer ratio is 5/5A and must be adapted to the current transformer employed if necessary. Direct measurement without a current transformer is not possible using the UMG 96RM-E. Only AC currents can be measured - DC currents cannot. Via the current measurement input I4 only an apparent current measurement is carried out thanks to the lack of a multiplier. Power measurements are therefore not possible using the I4 input. Load L1 L2 L3 c Caution! The test leads must be designed for an operating temperature of at least 80°C. Fig. Current measurement (I1-I3) via current transformers (connection example) c Caution! The current measurement inputs are dangerous to touch. m 22 N The attached screw terminal has to be fixed sufficiently with two screws on the device! m Caution! The UMG 96RM-E is not suitable for measuring DC voltages. C It is not necessary to configure a connection schematic for the I4 measurement input. N L3 L1 Earthing of current transformers! If a connection is provided for the earthing of secondary windings then this must be connected to the earth. Load c L2 UMG 96RM-E Fig. Current measurement (I4) via current transformer (connection example) 23 UMG 96RM-E Current direction The current direction can be individually corrected via the existing serial interface or on the device for each phase. If incorrectly connected, a subsequent re-connection of the current transformer is not required. When residual current measurements (RCM) are being carried out, there is no direction sensitive difference in the residual currents on the network or load side (not directionally sensitive). c 24 Current transformer connections! The secondary connection of the current transformer must be short-circuited on this before the current feed to the UMG 96RME is disconnected! If a test switch, which automatically shortcircuits the secondary wires of the current transformer, is available then it is sufficient to set this to the "Test" position insofar as the short-circuiting device has been checked beforehand. c c c Caution! A residual current measurement is done using the terminals I5 and I6 (see page 30). There is no directional sensitivity of the residual currents on the network or load sides (not directionally sensitive). Earthing of current transformers! If a connection is provided for the earthing of secondary windings then this must be connected to the earth. Open-circuit current transformers! High voltage spikes that are dangerous to touch can occur on current transformers that are driven with open-circuit secondary windings! With "safe open-circuit current transformers" the winding insulation is rated such that the current transformer can be driven open. However, even these current transformers are dangerous to touch when they are driven open-circuit. UMG 96RM-E c Caution! The UMG96RM is only approved for a current measurement using the current transformer. 25 UMG 96RM-E Wiring diagrams, current measurement (I1-I3) • 3p 4w (Addr. 510= 0), factory setting • 3p 2i (Addr. 510 = 1) L1 L1 L2 L2 L3 N L3 N I1 I2 I3 Fig. Measurement in a three-phase network with non-uniform load. • 3p 2i0 (Addr. 510 = 2) I1 • 3p 3w3 (Addr. 510 = 3) L1 L2 L2 L3 L3 I2 I3 Fig. The measured values for the current measurementinput I2 are calculated. 26 I3 Fig. System with uniform phase loading. The measured values for the current measurement input I2 are measured. L1 I1 I2 I1 I2 I3 Fig. Measurement in a three-phase network with non-uniform load. UMG 96RM-E • 3p 3w (Addr. 510 = 4) • 2p 4w (Addr. 510 = 5) L1 L1 L2 L2 L3 N L3 N I1 I2 I3 Fig. System with uniform phase loading. The measured values for the current measurement inputs I2 and I3 are calculated. • 1p 2i (Addr. 510 = 6) L1 I1 I2 I3 Fig. System with uniform phase loading. The measured values for the current measurement input I2 are calculated. • 1p 2w (Addr. 510 = 7) L1 L2 N I1 I2 I3 Fig. The null is taken from the current measurement input I3's measured value and not calculated. I1 I2 I3 Fig. The null is taken from the current measurement inputs I2 and I3 measured values and not calculated. 27 UMG 96RM-E Wiring diagrams, current measurement (I1-I3) Ammeter • 3p 1w (Addr. 510 = 8) If you wish to measure the current not just using the UMG 96RM, rather also with a ammeter, the ammeter must be connected to the UMG 96RM-E in series. L1 L2 L3 L1 L2 L3 UMG L1 L2 L3 S1 I S2 A I1 I2 I3 Fig. 3 systems with uniform phase loading. The not connected measured values I2/I3, I1/I3 and I1/I2 of the respective systems are calculated. Einspeisung Supply (k)S1 S2(l) (K)P1 P2(L) Verbraucher Consumer Fig. Current measurement with an additional ammeter (example). 28 UMG 96RM-E Total current measurement If the current measurement is done via two current transformers, the overall transformation ratio of the current transformers must be programmed into the UMG 96RM-E. The UMG 96RM-E must then be setup as follows: Primary current: 1000A + 1000A = 2000A Secondary current: 5A UMG I S1 S2 Einspeisung 1 Supply 1 1P1 (K) (L) 1P2 1S1 (k) (l) 1S2 Verbraucher A Consumer A P1 1S1 1S2 Example: The current is measured via two current transformers. Both current transformers have a transformation ratio of 1000/5A. The total measurement is done using a total current transformer 5+5/5A. P2 2S1 2S2 Einspeisung 2 Supply 2 2S1 (k) (l) 2P1 2S2 2P2 (K) (L) Verbraucher B Consumer B Fig. Current measurment using a total current transformer (example). 29 UMG 96RM-E Analog inputs The UMG 96RM-E has 2 analog inputs which can be used for one residual current measurement or one temperature measurement. The measurement is done using terminals 32-34 (input 1) or 35-37 (input 2). The analog inputs can be used for residual current or temperature measurement in accordance with the following table: Measurement Terminal Temperature 32/34 (input 1) and 35/37 (input 2) Residual current 32/33/34 (input 1) and 35/36/37 (input 2) 30 c Attention! Operating equipment connected to the analogue inputs must exhibit reinforced or double insulation from mains supply circuits! Example - temperature sensor: A temperature sensor in close proximity to non-isolated mains cables should measure within a 300V CAT III network. Remedy: The temperature sensor must be equipped with reinforced or double insulation for 300V CAT III. This equates to a test voltage for the temperature sensor of 3000V AC (duration 1 min.). Example - residual current transformer: A residual current transformer should measure on isolated mains cables within a 300V CAT III network. Remedy: The insulation of the mains cables and the insulation of the residual current transformer must fulfil the basic insulation requirements for 300V CAT III. This equates to a test voltage of 1500V AC (duration 1 min.) for the insulated mains cables and a test voltage of 1500 V AC (duration 1 min.) for the residual current transformer. UMG 96RM-E Residual current measurement (RCM) via I5, I6 The UMG 96RM-E is for use as a residual current monitoring device (RCM), suitable for monitoring AC, pulsing DC, and DC. The UMG 96RM-E can measure residual currents in accordance with IEC/TR 60755 (2008-01) of type A and type B. *1 *1 C Residual current transformer ratio The GridVis software included with delivery can be used to individually program the residual current transformer inputs' transformer ratios. Load The connection from suitable external residual current transformers with a rated current of 30 mA is done via the residucal current transformer inputs I5 (terminals 33/34) and I6 (terminals 36/37). PE N L1 L2 L3 Fig. Connection example residual current measurement via current transformers *1 Please note: Jumpers between connectors 32-33 respectively 35-36 are only required from hardware-release 104! 31 UMG 96RM-E Connection example, residual current monitoring Residual current transformer L1 L2 L3 PEN N PE Fig. Example UMG96RM-E with residual current monitoring via measuring inputs i5/I6. C 32 Residual current transformer L1 L2 L3 N I1 I2 I3 UMG 96RM-E (RCM) I t i s n o t n e c e s s a r y t o c o n f i g u re a connection schematic for residual current inputs I5 and I6. I4 I5 I6 M 3~ UMG 96RM-E Temperature measurement input The UMG 96RM-E has two temperature measuring inputs. The temperature is measured via terminals 32/34 (input 1) and 35/37 (input 2). Do not exceed the total resistance load (sensor + cable) of 4kOhm. PT100 PT100 m Use a shielded cable to connect the temperature sensor. Fig. Example, temperature measurement with a Pt100 33 UMG 96RM-E RS485 interface Termination resistors In UMG 96RM-E, the RS485 interface is designed as a 2 pin plug contact, which communicates via the Modbus RTU protocol (also see Parameter programming). The cable is terminated with resistors (120Ohm, 1/4W) at the beginning and at the end of a segment. The UMG 96RM-E does not contain any termination resistors. Correct RS485 interface, 2-pole plug contact RS485 bus Incorrect A B RS485 interface, 2-pole plug contact with terminating resistor (Item no. 52.00.008) 120 Ω 34 RS485 bus A B Terminal strip in the cabinet. Device with RS485 interface. (without terminating resistor) Device with RS485 interface. (with terminating resistor on the device) UMG 96RM-E Screening Cable type Twisted screened cable should be used for connections via the RS485 interface. The cable used must be suitable for an environmental temperature of at least 80°C. • Earth the screens of all cables that lead to the cabinet, upon entering the cabinet. • Connect the screens over a generous area and in a manner that will conduct well, to a low-noise earth. • Gather the cables mechanically above the earthing clamp in order to avoid damage due to cable movements. • Use suitable cable glands to feed the cables into the cabinet - for example armoured conduit couplings. Recommended cable types: Unitronic Li2YCY(TP) 2x2x0.22 (from Lapp Kabel) Unitronic BUS L2/FIP 1x2x0.64 (from Lapp Kabel) Maximum cable length 1200m at a baud rate of 38.4k. Cable Strain relief Screen braid of the cable Earthing clamp C Low-noise earth For the wiring of the Modbus connection, CAT cables are not suitable. Please use the recommended cables. Fig. Screening procedure at cabinet entry. 35 UMG 96RM-E Bus structure • All devices are connected in a bus structure (line) and each device has its own address within the bus (also see programming parameters). • Up to 32 stations can be interconnected in one segment. • The cable is terminated with resistors (bus termination, 120 ohm 1/4 W) at the beginning and end of a segment. • If there are more than 32 stations, repeaters (line amplifiers) must be used in order to connect the individual segments. • Devices with activated bus termination must be supplied with power. • It is recommended to set the master at the end of a segment. • The bus is inoperative if the master is replaced with an activated bus termination. • The bus can become unstable if the slave is replaced with an activated bus termination or is dead. • Devices that are not involved in the bus termination can be exchanged without making the bus unstable. • The shield has to be installed continuously and needs to be broadly and well conducting connected to an external low voltage (or potential) ground at the end. Power supply necessary Master T Bus terminator on T T Slave Slave Slave Repeater T T Slave Slave Slave Slave Fig. Bus structure 36 UMG 96RM-E Ethernet interface The Ethernet network settings should be specified by the network administrator and set on UMG 96RM-E accordingly. If the network settings are not known, the UMG 96RME may not be integrated into the network through the patch cable. m m Ethernet Connection PC / Switch Caution! Connection of the UMG96RM-E to the Ethernet may only be carried out after discussion with the network administrator! Caution! The UMG 96RM-E is factory-programmed for the dynamic allocation of the IP settings (DHCP mode). Settings can be changed as described in TCP/IP Configuration or, for example, via an appropriate Ethernet connection by means of GridVis software. 37 UMG 96RM-E Digital in-/outputs The UMG 96RM-E has 2 digital outputs and 3 optional digital inputs or outputs, which are divided into two groups (see figure). This means that only entire group 2 (connection 28 to 31) operate either as input or output; a different allocation within the group is not possible! Digital outputs, Group 1 • The status indicator appears on the display at K1 or K2 • The status indicator on the display is not dependent on an inversion being activated (NC / NO) K1/K2 display status indicator Source e.g. Comparator group 38 Digital outputs, Group 2 • The status of the inputs and outputs in Group 2 is indicated by the associated LED (cf. chapter LED status bar). Source C Inverter Digital output 1 Inverter e.g. Comparator group Digital output 3 The digital outputs of group 2 are not AC compatible. UMG 96RM-E Digital outputs Group 2 These outputs are galvanically separated from the analysis electronics using optocouplers. The digital outputs have a joint reference. ~ • The digital outputs of group 1 can switch DC and AC loads. The digital outputs of group 2 can not switch AC loads. • The digital outputs are not short-circuit proof. • Connected cables that are longer than 30m must be shielded when laid. • An external auxiliary voltage is required. • The digital outputs can be used as impulse outputs. • The digital outputs can be controlled via Modbus. • The digital outputs can display the results of comparators. ~ Fig. Connection digital / pulse outputs Group 1 39 UMG 96RM-E DC connection example C Functions for the digital outputs can be adjusted clearly in the GridVis software provided in the scope of deliverables. A connection between the UMG 96RM-E and the PC via an interface is required for the use of the GridVis software. External Auxiliary voltage UMG 96RM-E 13 Digital Ouput 1 Group 1: m Caution! Digital outputs are not short-circuit proof. Digital Ouput 2 14 24V DC + 15 LED 28 LED DC 30 Digital Ouput 5 31 Fig. Example for two relays connected to the digital outputs 40 K2 Digital Ouput 4 K1 29 LED When using the digital outputs as pulse outputs the auxiliary voltage (DC) must have a max. residual ripple of 5%. Group 2: C DC Digital Ouput 3 - UMG 96RM-E Digital inputs When allocating Group 2 as inputs, the UMG96 RM-E has three digital inputs to each of which you can connect one signal transducer. When a signal is present, the corresponding LED lights up green. An input signal is detected on a digital input if a voltage of at least 10V and maximum 28V is applied and where a current of at least 1mA and maximum 6mA flows at the same time. Wiring longer than 30m must be screened. Note the correct polarity of the supply voltage! External Auxiliary voltage - UMG 96RM-E Digital inputs 1-3 + Group 2 + 28 2k21 2k21 - 24V DC 2k21 2k21 2k21 2k21 29 Digital Input 1 S1 30 Digital Input 2 31 Digital Input 3 S2 S3 2k21 Fig. Connection example for digital Fig. Example for the connection of external switch contacts S1 and S2 to digital inputs 1 and 2. inputs. 41 UMG 96RM-E S0 pulse input You can connect an S0 pulse DIN EN62053-31 to any digital input. transducer per This requires an auxiliary voltage with an output voltage in the range 20 .. 28V DC and a resistor of 1.5kOhm. External Auxiliary voltage 24V DC - UMG 96RM-E Digital inputs 1-3 28 1.5k 2k21 2k21 2k21 2k21 2k21 2k21 29 Digital Input 1 S0 pulse transducer 30 Digital Input 2 31 Digital Input 3 2k21 Fig. Example for the connection of an S0 pulse transducer to digital input 1. 42 + UMG 96RM-E The different statuses of the inputs and outputs are displayed via the LED status bar on the rear of the device. Digital inputs The LED assigned to a respective input lights up green when a signal of at least 1mA flows on this interface. Digital outputs The LED assigned to a respective output lights up red when the output is set as enabled - regardless of whether there is a continuing connection to this interface. Digital in-/output 1 Digital in-/output 2 Digital in-/output 3 LED status bar LED status bar Fig. LED status bar for inputs and outputs 43 UMG 96RM-E Operation Programming mode The UMG 96RM-E is operated via buttons 1 and 2 with the following functions: • briefly pressing button 1 and 2: next step (+1) • pressing and holding button 1 and 2: previous step (-1) Measured values and programming data are displayed on an LCD display. You can view and change the necessary settings of the UMG 96RM-E in programming mode. Press button 1 and 2 simultaneously for about 1 second to switch to programming mode after entering the password. If no password is programmed, you get directly to the programming mode menu. Programming mode is marked by the text „PRG“ on the display. There are display and programming modes. You can avoid an unintentional change of programming data by entering a password. Display mode In display mode, you can scroll through the programmed measured values by pressing buttons 1 and 2. When the device is delivered, all measured value indications of profile 1 can be retrieved. For each measured value, up to three measured values are indicated. The measured value rotation can display selected measured value indications one after the other with a selectable changing time. 44 Press button 2 to switch between the following menus: - Current transformer, - Voltage transformer, - Parameter list, - TCP/IP device address, - Subnet mask, - Gateway address, - Dynamic TCP/IP addressing (in/out). If no button was pressed for about 60 seconds when you are in programming mode, or button 1 and 2 are pressed simultaneously for about 1 second, the UMG 96RM-E will switch back to display mode. UMG 96RM-E Max. value, HT/reference Min. value, NT/supply Mean value Programming mode Total measurement External conductor External conductor Password CT:current transformer VT:voltage transformer K1: output 1 K2: output 2 Button 2 Supply Button 1 45 UMG 96RM-E Parameters and measured values Parameter indication example All necessary parameters for the use of UMG 96RM-E, such as current transformer data and frequently required measured values are provided in the table. Use the UMG 96RM‑E buttons to retrieve the contents of most of the addresses via serial interface. In this example, the contents of address "000" is indicated by the value "001" on display of the UMG 96RM‑E. This parameter specifies the device address (in this case "001") according to the list of the UMG 96 RM-E within a bus. You can only enter the first 3 significant digits of a value on the device. Values with more digits can be entered using GridVis. The first 3 significant digits of a value are displayed on the device. Selected measured values are summarized in measured value profiles and can be indicated in display mode by pressing button 1 and 2. The current measured value profile, the display change profile, plus date and time can be read and changed via the RS485 interface only. 46 Measured value indication example In this example, the voltage L-N is indicated by 230V on the display of the UMG 96RM‑E. The transistor outputs K1 and K2 are active, which ensures the current flow. UMG 96RM-E Button functions Display mode Programming mode Select mode Select mode Password simultaneously simultaneously Scroll Scroll short short Measured value A(+1) ... long long Measured value A(-1) long Programming menu +1 Measured value B ... Program short For an overview of the measured value indications, see chapter "Overview of measured value indications". Programming menu -1 Programming menu 1 (flashing) (flashing) Confirm selection short: Number +1 long: Number -1 short: Value x 10 (Decimal point to the right) long: Value/10 (Decimal point to the left) 47 UMG 96RM-E Configuration Connecting the supply voltage The supply voltage must be connected the configuration of the UMG 96RM-E . for c The level of the supply voltage for the UMG 96RM‑E is specified on the rating plate. If no display appears, check whether the operating voltage lies within the nominal voltage range. Current and voltage transformers When the device is delivered, a current transformer ratio of 5/5A is entered. The voltage transformer ratio must only be changed if a voltage transformer is connected. C m When connecting a voltage transformer, please note the measurement voltage of UMG 96RM-E given on the rating plate. C 48 Caution! If the supply voltage does not correspond to the voltage indicated on the rating plate, this may lead to malfunctions severe damage to the device. The adjustable value 0 for the primary current transformer does not produce any useful work data, and should not be used. Devices with an automatic frequency detection require about 5 seconds to determine the mains frequency. In the meantime, measured values do not maintain the guaranteed measurement uncertainty. Prior to commissioning potential production dependant contents of the energy counter, min/max values and records have to be deleted. UMG 96RM-E C Current and voltage transformers The GridVis software included with delivery can be used to individually program the current and voltage transformer input transformer ratios. Only the transformer ratio of the respective group of the current inputs I1-I3 and the voltage measurement inputs V1-V3 can be adjusted on the device. The transformer ratio of the current transformer input I4 and the residual current transformer inputs I5, I6 should be set in the GridVis software. Fig. Indication to configure the current and voltage transformers in the GridVis software. Current transformer input I4 Thus, with a voltage only an apparent current can be measured at the current converter input l4 due to the multiplier being missing. This input can not be used for power measurements. The transformer ratio can be adjusted in the GridVis software. 49 UMG 96RM-E Programming the current transformer for I1 to I3 Switch to the programming mode • Press button 1 and 2 simultaneously to switch to the programming mode. If a user password was programmed, the password menu appears in display with the indication „000“. The first digit of the user password is flashing and can be changed by pressing button 2. Press button 2 to select the next digit while it is flashing. You can get to the programming mode after entering the correct code, or if no user password was programmed. • The symbols for the programming mode PRG and the current transformer mode CT appear on the display. • Press button 1 to confirm the selection. • The first digit of the input field for the primary current is flashing. Input of the current transformer primary current • Press button 2 to change the flashing digit. • Press button 1 to select the next digit to be changed. The selected digit to be changed is flashing. If the entire number is flashing, press button 2 to move the decimal point. 50 Input of the current transformer secondary current • Only 1A or 5A can be set as secondary current. • Press button 1 to select the secondary current. • Press button 2 to change the flashing digit. Exit programming mode • Press both buttons the programming mode. simultaneously to exit UMG 96RM-E Programming the voltage transformer • Select in the programming mode as described. The symbols for the programming mode PRG and the current transformer mode CT appear on the display. • Press button 2 to go to the voltage transformer settings. • Press button 1 to confirm the selection. • The first digit of the input field for the primary voltage is flashing. The voltage transformer ratio can be set from primary to secondary voltage in a way similar to the allocation of the current transformer ratio. Current transformer, primary Programming mode Display of units Current transformer, secondary Current transformer symbol Voltage transformer, primary Programming mode Display of units Voltage transformer, secondary Voltage transformer symbol 51 UMG 96RM-E Programming parameters Switch to the programming mode • Select in the programming mode as described. The symbols for the programming mode PRG and the current transformer mode CT appear on the display. • Press button 2 to go to the voltage transformer settings. Press button 2 repeatedly to view the first parameter in the list. Changing parameters • Press button 1 to confirm the selection. • The last selected address and the corresponding value is indicated. • The first digit of the address is flashing and can be changed by pressing button 2. Press button 1 to select and change the digit with button 2. Change value • If the desired address is set, press button 1 to select a number of the value and change it by pressing button 2. Exit programming mode • Press both buttons the programming mode. 52 simultaneously to exit Fig. Password query Use button 1 and 2 to enter a password (if any). Fig. Current transformer programming mode Use button 1 and 2 to change primary and secondary current (see page 50). Fig. Programming mode Voltage converter Use button 1 and 2 to change primary and secondary voltage (see page 51). Fig. Programming mode Parameter indication Use button 1 and 2 to change individual parameters (see page 46). UMG 96RM-E TCP/IP configuration Description Within an Ethernet, each device has a unique TCP / IP address that can be assigned manually or from a DHCP server. The 4-byte device address (0 to 3 byte) can be extended in the TCP / IP configuration using the subnet mask and gateway data. Setting the TCP / IP device address (addr) manually • Select in the programming mode as described. The symbols for the programming mode PRG and the current transformer mode CT appear on the display. • Press button 2 three times to get to the TCP / IP settings for the device addressing. • Press button 1 to select the desired digit. The selection is indicated by a flashing digit. • Press button 2 to adjust the selected digit. • Use button 1 to select the next digit and set it again by pressing button 2. • If byte is set to 0, the TCP / IP address can be set from 1 to 3 by pressing button 1. Then the display jumps back to Byte 0 (no digit is flashing). Byte identification (e.g. byte 0) of the address Address value, byte 0 Fig. TCP/IP address, byte 1 A TCP / IP address consists of 4 bytes with the following structure: Byte 0 Byte 1 Byte 2 Byte 3 xxx.xxx.xxx.xxx Example:1 9 2 . 168.003. 1 7 7 Fig. TCP / IP address, byte 2, value 003 Fig. TCP / IP address, byte 3, value 177 53 UMG 96RM-E Manual setting of the subnet mask (SUb) • When in the programming mode, press button 2 to get to the subnet mask settings (SUb display). • Use button 1 to select the desired digit and set it by pressing button 2. Repeat this step for each digit in bytes 0 to 3 in a way similar to setting the TCP / IP device address. • After repeated display of byte 0 (no digit is flashing) one can set the gateway address. Manual setting of the gateway address (GAt) • When in the programming mode, press button 2 to get to the gateway address settings (GAt display). • Press buttons 1 and 2 to set the desired gateway address in bytes 0 to 3 as described above. Disable the dynamic IP allocation (dYN IP, oFF) to ensure that the manual settings of the TCP / IP device address, subnet mask and gateway address are not overwritten by a DHCP server. C 54 Changes will only take effect after you exit the programming mode. Dynamic IP allocation (dyn) The dynamic allocation of the TCP / IP settings (device/ gateway address and subnet mask) provides for a fully automated integration of the device into an existing network with a DHCP server. TCP / IP settings do not need to be configured manually as they are automatically assigned by the DHCP server when the device is started. Addresses are read out in the programming mode the same way as in the manual settings. • Switch to the programming mode as described. The symbols for the programming mode PRG and the current transformer mode CT appear on the display. • Press button 2 several times to display the dynamic IP allocation (dYn IP). • Press button 1 to enable the parameter "on" or "oFF" (parameter is flashing). • Press button 2 to select the parameter and confirm by pressing button 1. Exit the programming mode or wait about 60 seconds. If the key symbol is displayed, the dynamic IP allocation is enabled. Device / gateway address and subnet mask are provided and automatically accepted by the DHCP server. UMG 96RM-E m Fig. Subnet mask (Sub), byte 0, value 255 Fig. Gateway (GAt), byte 0, value 192 m Caution! Connection of the UMG96RM-E to the Ethernet may only be carried out after discussion with the network administrator! Caution! The UMG 96RM-E is factory-programmed for the dynamic allocation of the IP settings (DHCP mode). Settings can be changed as described in TCP/IP Configuration or, for example, via an appropriate Ethernet connection by means of GridVis software. Fig. Enabled dynamic allocation (dYn IP) of the TCP / IP address Fig. Disabled dynamic allocation (dYn IP) of the TCP / IP address 55 UMG 96RM-E RS485 device address (Addr. 000) RS485 baud rate (Addr. 001) If multiple devices are connected to each other via the RS485 interface, a master device can only identify the devices by their device address. Within a network, each device must have its own device address. Addresses can be set in the range of 1 to 247. A common baud rate can be adjusted for the RS485 interfaces. The baud rate must be uniform for all devices on the network. Address 003 can be used to set the number of stop bits (0=1bit, 1= 2bits). Data bits (8) are fixed default values. C 56 The adjustable range of the device address is between 0 and 255. Values 0 and 248 through 255 are reserved and may not be used. Setting Baud rate 0 9.6kbps 1 19.2kbps 2 38.4kbps 3 57.6kbps 4 115.2kbps (factory setting) UMG 96RM-E MODBUS gateway (Addr. 002) User password (Addr. 050) Set address 002 as described in the table below to use the UMG 96RM-E Modbus Gateway function: A user password can be programmed to prevent accidental change of the programming data. Changes in the programming menu below can only be made after entering the correct user password. User password is not factory-programmed. In this case, the password menu is skipped and you get directly to the current transformer menu. Setting Baud rate 0 Modbus Gateway disabled (OFF) (Factory setting) 1 Modbus Gateway enabled (ON) If a user password was programmed, the password menu appears on the display with the indication „000“. The first digit of the user password is flashing and can be changed by pressing button 2. Press button 1 to select the next digit while it is flashing. You can only get to the current transformer programming menu after entering the correct code. Forgot my password If you do not remember your password, you can only delete it using the GridVis PC software. In order to do so, connect the UMG96RM-E to the PC with a suitable interface. More information can be found in the GridVis assistant. 57 UMG 96RM-E Parameter Averaging method Mean value The applied exponential messaging method reaches at least 95% of the measurement value once the reporting time has run its course. Mean values are averaged over an adjustable period for the current, voltage and power measured values. The mean values are indicated by a bar over the measured value. The averaging time can be selected from a list with 9 fixed averaging times. Averaging time, current (Addr. 040) Averaging time, power (Addr. 041) Averaging time, voltage (Addr. 042) 58 Setting Averaging time/sec. 0 1 2 3 4 5 6 7 8 5 10 15 30 60 300 480 (factory setting) 600 900 Min. and max. values All measured values are measured and calculated during all 10/12 periods. Minimum and maximum values are determined for most measured values. The min. value is the smallest measured value determined since the last deletion. The max. value is the highest measured value determined since the last deletion. All minimum and maximum values are compared with the corresponding measured values and overwritten when exceeded or fallen short of. The minimum and maximum values are saved every 5 minutes in an EEPROM without date and time. Thus, the minimum and maximum values of the past 5 minutes may be lost due to an operating voltage failure. Delete min. and max. values (Addr.506) If „001“ is set for address 506, all minimum and maximum values can be deleted simultaneously. UMG 96RM-E Mains frequency (Addr. 034) For automatic ascertainment of the mains frequency, an L1-N voltage larger than 10Veff must be applied to the voltage measurement input V1. The sampling frequency is computed for the current and voltage inputs based on the mains frequency. Setting range: 0, 45 .. 65 0 = automatic frequency determination. The mains frequency is determined based on the measurement voltage. 45..65 = fixed frequency The mains frequency is pre-selected as a fixed value. If the test voltage is missing, neither the network nor the sampling frequency can be computed. An acknowledgeable error message "500" will be displayed. Voltage, current and all resulting values are calculated and displayed based on the most recent frequency measurement and/or possible power couplings. The measured values that have been determined can no longer guarantee the declared precision. When another measurement of frequency can be carried out, the error message will automatically disappear in about 5 seconds after the voltage returns. The error is not displayed when a fixed frequency is set. 59 UMG 96RM-E Energy meter Reset energy meter (Addr. 507) The UMG 96RM-E has power meters for active energy, reactive energy and apparent energy. The real, apparent and reactive energy meters can only be reset simultaneously. Set "001" for address 507 to reset the energy meter. Active energy reading Total active energy The active energy given in this example is 12 345 678 kWh C C The active energy given in this example is 134 178 kWh 60 Prior to commissioning potential production dependant contents of the energy counter, min/max values and records have to be deleted. If you reset the energy meter, the data will be lost. To avoid data loss, you should read and save the measured values before deletion using the GridVis software. UMG 96RM-E Harmonics Total harmonic distortion THD Harmonics are integer multiples of a fundamental oscillation. The fundamental oscillation of the voltage for UMG 96RM-E must range between 45 and 65Hz. The calculated harmonic voltages and currents relate to this fundamental oscillation. Harmonics up to 40 times the fundamental frequency are detected. THD is the ratio of the rms value of the harmonics to the rms value of the fundamental oscillation. The harmonics of the currents and of the voltages are displayed in amperes and volts, respectively. Total harmonic distortion of the current THDI: Total harmonic distortion of the voltage THDU: Number of the harmonic component Phase L3 Current harmonics Value Fig. Indication of the 15th harmonics of the current in phase L3 (example). C Harmonics are not displayed in the default factory setting. Phase L3 Voltage Value Fig. Indication of the total harmonic distortion THD of the voltage of phase L3 (example). 61 UMG 96RM-E Measured value rotation Rotation time (Addr. 039) All 10/12 periods the measured values are calculated and the readings are displayed on a per second basis. There are two ways to retrieve the measurement readings: Setting range : 0 .. 60 seconds If 0 seconds are set, the measured value indications selected will not be rotated. The rotation time set applies to all display rotation profiles. • The automatically changing indication of the selected measurement readings is referred to herein as measured value rotation. • Press button 1 and 2 to select measured value indication from a pre-selected display profile. Both methods are available simultaneously. The measured value rotation is enabled when at least one measured value indication change time is over 0 seconds. Press a button to scroll the measured value indications of selected display profile. If no button is pressed for about 60 seconds, the device will switch to the measured value rotation to display the programmed measured value indications from the selected rotation profile in succession. 62 Display rotation profile (Addr. 038) Setting range: 0 .. 3 0 - Display rotation profile 1, pre-programmed. 1 - Display rotation profile 2, pre-programmed. 2 - Display rotation profile 3, pre-programmed. 3 - Display rotation profile, customizable. Measured value indocations Following a power resumption, the UMG 96RM-E displays the first measurement value table in the current display profile. To keep the selection to a manageable size, only a fraction of the available measurement values was preprogrammed in the factory for retrieval in the measured value display. Select another display profile to view other measured values on the UMG 96RM-E display. UMG 96RM-E Display profile (Addr. 037) Setting range: 0 .. 3 0 - Display profile 1, default value. 1 - Display profile 2, default value. 2 - Display profile 3, default value. 3 - Display profile, customizable. C C The customizable profiles (display rotation profile and display profile) can only be programmed using the GridVis software. Profile setting Both profiles (display rotation profile and display profile) are illustrated in the GridVis software included in the delivery package. The profiles can be adjusted using the Device Configuration function of the software; customizable display profiles are programmed individually. A connection between the UMG 96RM-E and the PC via an interface is required for the use of the GridVis software Fig. Profile setting in the GridVis software. 63 UMG 96RM-E Phase sequence LCD contrast (Addr. 035) The voltage phase sequence and the phase L1 frequency are displayed on the screen. The preferred view for the LCD display is from "below". The LCD display contrast can be adapted by the user. The contrast can be set stepwise in the range from 0 to 9. The phase sequence shows the three-phase system sequence. The rotary field usually rotates to the "right". The voltage measurement input phase sequence is checked and displayed in the UMG 96RM-E. If the string moves in a clockwise direction, this means that the rotary field rotates to the "right"; if the string moves in a counter-clockwise direction, this means that the rotary field rotates to the "left". The field rotation can only be determined when the measurement and operating voltage inputs are fully connected. If a phase is missing or two equal phases are connected, then the phase sequence is not determined and the string is not moving. 0 = very bright 9 = very dark Factory default setting: 5 Backlight The LCD backlight allows the display to be read easily even in poor light. The brightness can be controlled by the user in stages from 0 to 9. The UMG 96RM has two different types of backlight: - the operation backlight - the standby backlight Fig. Indication of the supply frequency (50.0) and the phase sequence. 64 Fig. Rotary field direction can not be determined. UMG 96RM-E Operation backlight (addr. 036) The operation backlight is activated by pushing the appropriate button, or with a restart. Standby backlight (addr. 747) This backlight is activated after an adjustable period of time (addr. 746). If no button is pressed within this period, then the device switches to the standby backlight. If buttons 1 - 3 are pressed, the device switches to the operation backlight and the defined period of time begins again. If the brightness settings for the two backlights are set to the same value, then no change is discernible between the operation and standby backlights. Addr. Description Setting range Default setting 036 Brightness for operation backlight 0 .. 9 6 746 Period of time after which the backlight will switch to standby 60 .. 9999 Sek. 900 Sek. 747 Brightness for standby backlight 0 .. 9 0 Time recording The UMG 96RM-E records the operating hours and the overall runtime of each comparator, • where the operating period is measured and displayed in hours with a resolution of 0.1 h • and the overall runtime of the comparators is displayed in seconds (when reaching 999999s is displayed in hours). The periods are marked by the digits 1 to 6 for the measured value display enquiry: keine = operating hours meter 1 = Overall runtime, comparator 1A 2 = Overall runtime, comparator 2A 3 = Overall runtime, comparator 1B 4 = Overall runtime, comparator 2B 5 = Overall runtime, comparator 1C 6 = Overall runtime, comparator 2C In the measured value display, a maximum of 99999.9 h (= 11.4 years) can be displayed. 0 = min. brightness, 9 = max. brightness 65 UMG 96RM-E Operating hours meter Serial number (Addr. 754) The operating hours meter measures the UMG 96RM-E recording and displaying time. The operating period is measured and displayed in hours with a resolution of 0.1 h. The operating hours meter cannot be reset. The serial number displayed by the UMG 96RM-E consists of 6 digits and is a part of the serial number given on the rating plate. The serial number cannot be changed. Serial number Overall runtime of comparators The overall runtime of a comparator is the sum of the runtimes exceeding the comparator result limit value. The total running time of the comparators can only be reset by the GridVis software. All running times are reset simultaneously. Fig. Measured value indications Operating hours meter The UMG 96RM-E operating hours meter reading is 140.8h. This corresponds to 140 hours and 80 industrial minutes. 100 industrial minutes = 60 minutes. In this example, 80 industrial minutes = 48 minutes. 66 The serial number is on the rating plate: XX00-0000 Software release (Addr. 750) The UMG 96RM-E software is continuously improved and extended. The software status in the device is identified with a 3 digit number, the software release. The software release cannot be changed by the user. UMG 96RM-E “Drag indicator” Max. value of the mean value over n minutes The “drag indicator” describes a maximum mean value of a measured value over a defined period. The period duration is set via a parameter, via the GridVis software or via the digital input 1. In the process, synchronisation is triggered via the internal clock (which can be set via parameter 206 or to a full hour) or optionally via digital input 1. If synchronisation via the digital input is selected, the capture time must be set! The thee highest values of 15 variables with time stamp are saved. The maximum values of the variables can also be viewed in the device display. Variables: • Current in the single phases L1.. L3 • Effective power (consumption/export) in the single phases L1.. L3 • Effective power (consumption/export), total. • Apparent power the single phases L1...L3 • Apparent power, total C Please note that even before averaging, the values are divided between positive and negative ones! During totalisation, first the totals for the single phases are calculated, then divided into positive and negative values! The maximum values are reset via the “Delete min./max. values” function with the GridVis program, via Modbus or on the display by setting the corresponding parameters (parameter 506: set from 0 to 1). Addr. Description Setting range 206 Period duration 300 .. 3600 sec. 900 Presetting 207 Capture time 1 .. 20 sec. 10 sec. 208 Configuration digital input 1 0 .. 2 0 0 = internal synchronisation 1 = external synchronisation (NO) 2 = external synchronisation (NC) 506 Resetting 0, 1 0 67 UMG 96RM-E Recordings 2 recordings are preconfigured in the default factory setting of the UMG 96RM-E. Recordings can be adjusted and extended via GridVis. • The min. recording time base is 1 minute. • Maximum 4 recordings, each with 100 measured values, are possible. Recording 1: The following measured values are recorded with the time base of 15 minutes: • Effective voltage L1 • Effective voltage L2 • Effective voltage L3 • Effective current L1 • Effective current L2 • Effective current L3 • Effective current sum L1..L3 • Effective power L1 • Effective power L2 • Effective power L3 • Effective power sum L1..L3 • Apparent power L1 • Apparent power L2 • Apparent power L3 • Apparent power sum L1..L3 68 • cos phi(math.) L1 • cos phi(math.) L2 • cos phi(math.) L3 • cos phi(math.) sum L1..L3 • Reactive power fundamental oscillation harmonic L1 • Reactive power fundamental oscillation harmonic L2 • Reactive power fundamental oscillation harmonic L3 • Reactive power fundamental oscillation harmonic sum L1..L3 The mean value, minimum value and maximum value are also recorded for each measured value. Recording 2: The following measured values are recorded with the time base of 1 hour: • Effective energy sum L1..L3 • Inductive reactive energy sum L1..L3 UMG 96RM-E Putting into service Applying the measuring-circuit current Connecting the supply voltage The UMG 96RM-E is designed for the connection of .. /1A and .. /5A current transformers. Only AC currents can be measured via the current measurement inputs - DC currents cannot. Short circuit all current transformer outputs except for one. Compare the currents displayed by the UMG 96RM with the applied current. Bearing in mind the current transformer conversion ratio, the current displayed by the UMG 96RM-E must correspond with the input current. The UMG 96RM-E must display approx. zero amperes in the short-circuited current measurement inputs. The current transformer ratio is factory set to 5/5A and must be adapted to the current transformer used if necessary. • The power supply voltage level for the UMG 96RM-E is given on the rating plate. • After applying the power supply voltage the device switches on to display the first measured value. • If no display appears, check whether the power supply voltage is within the rated voltage range. Applying the measuring-circuit voltage • Measurement of voltages in the mains with over 300VAC to earth must be connected via voltage transformers. • After connecting the measurement-current voltages, the measured values displayed by the UMG 96RM-E for the L-N and L-L voltages must correspond to those at the voltage measurement input. m Caution! Voltages and currents that are outside the permissible measuring range can lead to personal injury and damage the device. m m Caution! If the supply voltage does not correspond to the voltage indicated on the rating plate, this may lead to malfunctions severe damage to the device. Caution! The UMG 96RM is not suitable for measuring DC voltages. 69 UMG 96RM-E Phase sequence Applying the residual current Check the direction of the voltage rotating field in the measured value display of the UMG 96RM‑E. A “right” rotating field usually exists. Connect residual current transformer only to the I5 and I6 inputs with a rated current of 30mA! Both residual current inputs can measure AC currents, pulsing direct currents and DC currents. Check phase assignment The assignment of the outer conductors to the current transformer is correct, if a current transformer is short circuited on the secondary, and the current indicated by the UMG 96RM-E drops to 0A in the corresponding phase. Bearing in mind the current transformer conversion ratio, the residual current displayed by the UMG96RM-E must correspond with the input current. The current transformer ratio is factory set to 5/5A and must be adapted to the residual current transformer used if necessary. Checking the energy measurement Short-circuit all current transformer outputs except for one and check the displayed power outputs. The UMG 96RM-E may only display one power output in the phase with a non short-circuited current transformer input. If this is not the case, check the connection of the measuring-circuit voltage and the measuringcircuit current. C If the power output amount is correct but the sign of the power output is negative, • S1(k) and S2(l) could be inverted at the current transformer • or they supply active energy back into the network. C 70 The UMG 96RM-E requires the mains frequency to measure the residual current. For this purpose, the measuringcircuit voltage should be applied or a fixed frequency should be set. It is not necessary to configure a connection schematic for residual current inputs I5 and I6. UMG 96RM-E Failure monitoring (RCM) for I5, I6 The UMG96RM-E enables continuous monitoring of the connection to the residual current transformer on inputs I5 and I6. Activation of failure monitoring is performed by setting address 21264 for the residual-current measurement input I5 and 21265 for I6. If there is an interruption in the connection to the current transformer, this state is recorded in certain registers or indicated in the GridVis software: m The failure monitoring is only available from firmware-ver. 202 and hardware-release 104! m Monitoring of the connection to the residual current transformer is only available in AC mode! Modbus addr. Value / Function 21264 (I5) 21265 (I6) Failure monitoring for I5 / I6 0 = Deactivate monitoring 1 = Activate monitoring Modbus addr. Value / Function 11623 (I5) 11624 (I6) 0 =Connection to the residual current transformer on to I5 or I6 error-free 1 =Error in the current transformer connection to I5 or I6 71 UMG 96RM-E Alarm status for I5, I6 Using bit-by-bit coding inside the alarm register (addr. 21095, 21096), it is possible to read out different alarm statuses: Bit: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 00000000 00000000 Unused Failure monitoring Alarm Overcurrent Warning Example: Interruption of the connection to the residual current transformer. The alarm bit is also set and must be acknowledged! Bit: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 00110000 00000000 Unused Failure monitoring Alarm Overcurrent Warning 72 Warning: The residual current has exceeded the set warning limit value Overcurrent: The measurement range has been exceeded Alarm: Alarm bit is set for: warning, overcurrent or connection error to the transformer. The alarm bit must be reset or acknowledged manually. Failure monitoring Connection error to the transformer UMG 96RM-E Checking the measurement Checking the total power outputs If all voltage and current inputs are correctly connected, the individual and cumulative outputs are computed and displayed correctly. If all voltages, currents and outputs for the respective outer conductors are correctly displayed, the total power outputs measured by the UMG 96RM must also be correct. To confirm this, the total outputs measured by the UMG 96RM should be compared with the work of the active and reactive power meters located in the incoming supply. Checking the individual outputs In case that a current transformer is assigned to the wrong outer conductor, the corresponding power output will be measured and indicated incorrectly. The assignment of the outer conductor and the UMG 96RM-E current transformer is correct, if no voltage is measured between the outer conductor and the corresponding current transformer (primary). In order to ensure that an outer conductor at the voltage measurement input is assigned to the correct current transformer, the respective current transformer can be short-circuited on the secondary side. The apparent power displayed by the UMG 96RM-E must then be approx. zero in this phase. If the apparent power is correctly displayed but the active power is displayed with a „-“ sign, then the current transformer terminals are reversed or power is supplied to the power supply company. 73 UMG 96RM-E RS485 interface The MODBUS RTU protocol with CRC check on the RS485 interface can be used to access the data from the parameter and the measured value lists. Address range: 1 .. 247 Factory default setting: 1 Number format: The device is factory set to address 1 and the baud rate of 115,2 kbps. C C Modbus functions (slave) 03 Read Holding Registers 04 Read input registers 06 Preset single register 16 (10Hex) Preset multiple registers 23 (17Hex) Read/write 4X registers The sequence of bytes is high before low byte (Motorola format). Transmission parameters: Data bits: 8 Parity: no Stop bits (UMG 96RM): 2 External stop bits: 1 or 2 74 short float 16 bit (-215 .. 215 -1. 32 bit (IEEE 754) Broadcast (address 0) is not supported by the device. The message length must not exceed 256 bytes. UMG 96RM-E Example: Reading the L1-N voltage The L1-N voltage is saved in the measured value list at address 19000. The L1-N voltage is available in the FLOAT format. Address = 01 is approved as the UMG 96RM-E device address. The Query Message appears as follows: The Response of the UMG96 RM-E can appear as follows: Description Device address Function Start Addr. Hi Start Addr. Lo Ind. Value Hi Ind. Value Lo Error Check Description Device address Function Byte meter Data Data Error Check (CRC) HexNote 01 UMG 96RM, address= 1 03 „Read Holding Reg.“ 4A 19000dez = 4A38hex 38 00 2dez = 0002hex 02 - HexNote 01 UMG 96RM, address= 1 03 06 00 00hex = 00dez E6 E6hex = 230dez - The L1-N voltage read by address 19000 is 230V. 75 UMG 96RM-E Digital outputs The UMG 96RM-E features two digital outputs in group 1. Three further outputs can be used in group 2. The User can allocate different functions to the digital outputs The functions can be programmed by using the configuration menu of the GridVis software. + = - S2 S3 K3 K4 K5 - - 24V = DC + = + K1 13 S1 14 K2 15 Group 11 Gruppe 28 29 30 31 Group 2 2 Gruppe Digital inputs/outputs Digital-Eingänge/Ausgänge Fig.: Digital inputs of group 1 and digital in- / outputs of group 2 76 Fig.: Software GridVis, configuration menu UMG 96RM-E Digital outputs - Status displays The status of the switching outputs of group 1 is indicated by circular symbols in the display of the UMG 96RM-E. C Since the indication is updated once per second, faster status changes of the outputs can not be displayed. Group 1 Status digital output 1 Status digital output 2 Digital output stati The current flow can be <1mA. Digital output 1: Addr. 608 = 0 Digital output 2: Addr. 609 = 0 The current flow can up to 50mA. Digital output 1: Addr. 608 = 1 Digital output 2: Addr. 609 = 1 77 UMG 96RM-E Impulse output The digital outputs can be used for the output of pulses for the computation of power consumption. For this purpose, a pulse of defined length is applied on the output after reaching a certain, adjustable amount of power. You need to make various adjustments in the software GridVis (configuration menu) to use a digital output as a pulse one. • Digital output, • Selection of source, • Selection of measured value, • Pulse length, • Pulse value. Fig.: Software GridVis, configuration menu 78 UMG 96RM-E Pulse length The pulse length applies to both pulse outputs and is set by the software GridVis. The typical pulse length of S0 pulse is 30ms. Pulse interval The pulse interval is at least as large as the selected pulse length. The pulse interval depends on the measured power, for example, and can take hours or days. Pulse length 10ms .. 10s Pulse interval >10ms The values in the table are based on the minimum pulse length and the minimum pulse interval for the maximum number of pulses per hour. Pulse length Pulse interval Max. pulse/h 10 ms 10 ms 180 000 pulse/h 30 ms 30 ms 60 000 pulse/h 50 ms 50 ms 36 000 pulse/h 100 ms 100 ms 18 000 pulse/h 500 ms 500 ms 3600 pulse/h 1 s 1 s 1800 pulse/h 10 s 10 s 180 pulse/h Examples of the maximum possible number of pulses per hour. C Pulse interval The pulse interval is proportional to the power output within the selected settings. C Measured value selection When programming with GridVis you have a selection of work values which are derived from the power output values. 79 UMG 96RM-E Pulse value The pulse value is used to indicate how much energy (Wh or varh) should correspond to a pulse. The pulse value is determined by the maximum connected load and the maximum number of pulses per hour. If you check the pulse value with a positive sign, the pulses will only be emitted when the measured value has a positive sign. If you check the pulse value with a negative sign, the pulses will only be produced when the measured value has a negative sign. Pulse value = C C 80 max. connected load max. number of pulses/h [Pulse/Wh] Since the active energy meter operates with a backstop, pulses will only be generated when drawing electricity. Since the reactive energy meter operates with a backstop, pulses will only be generated with inductive load applied. UMG 96RM-E Determine the pulse value External 230V AC operating voltage Set the pulse length Set the pulse length in accordance with the requirements of the connected pulse receiver. At a pulse length of 30 ms, for example, the UMG96RM generates a maximum number of 60,000 pulses (see Table "maximum number of pulses" per hour. Determining the maximum connected load Example: Current transformer = 150/5A Voltage L-N = max. 300 V Power per phase Power at 3 phases Max. connected load = 150 A x 300 V = 45 kW = 45kW x 3 = 135kW 24V DC + UMG 96RM-E - Switch and pulse outputs 13 +24V= Data logger 14 1.5k 15 Fig.: Connection example for the circuit as pulse output. Calculating the pulse value Pulse value = Pulse value Pulse value Pulse value max. connected load max. number of pulses/h [Pulse/Wh] = 135kW / 60,000 Imp/h = 0,00225 kWh / pulse = 2,25 Wh / pulse C When using the digital outputs as pulse outputs the auxiliary voltage (DC) must have a max. residual ripple of 5%. 81 UMG 96RM-E Comparators and monitoring threshold values Five comparator groups (1-5) and 10 comparators per group (A – J) can be selected in order to monitor/control the thresholds. The results of the comparators A to J can be linked with AND or OR operators The result of the AND and OR operator can be allocated to the respective digital output. The function “display blinking” can be additionally assigned to every comparator group. The effect is the change of the display backlight between maximum and minimum brightness when the comparator output is active. Fig.: Software GridVis, configuration menu 82 UMG 96RM-E Comparator running times Comparator running times are time counters, which are added together at a set comparator output. i.e. if the condition of the comparator is fulfilled and the lead time has elapsed, the counter is increased by the corresponding amount of time - this does not take account of the min. switch-on time! Comparator with set limit value violation • The set limit value is compared to the measured value. • If the limit value violation occurs for at least the duration of the lead time, the comparator result is changed. • The result is retained for at least the duration of the min. switch-on time and for no longer than the duration of the limit value violation. If there is no longer a limit value violation and the min. switch-on time has elapsed, the result is reset. Measured value Limit value Limit value violation (e.g. exceedance) Lead time Minimum switch-on time 2 seconds 6 seconds Comparator result Comparator running time 83 UMG 96RM-E Service and maintenance Service The device is subjected to several different safety tests before leaving the factory and is labelled with a seal. If a device is opened then the safety checks must be repeated. Warranty claims will only be accepted if the device is unopened. Should questions arise, which are not described in this manual, please contact the manufacturer directly. Repair and calibration - Device name (see rating plate), - Serial number (see rating plate), - Software release (see measured value display), - Measuring-circuit voltage and power supply voltage, - Precise description of the error. Repair work and calibration can be carried out by the manufacturer only. Front film The front film can be cleaned with a soft cloth and standard household cleaning agent. Do not use acids and products containing acid for cleaning. Disposal The UMG 96RM can be reused or recycled as electronic scrap in accordance with the legal provisions. The permanently installed lithium battery must be disposed of separately. 84 We will need the following information from you to answer any questions: Device calibration The devices are calibrated by the manufacturer at the factory - it is not necessary to recalibrate the device providing that the environmental conditions are complied with. Calibration intervals It is recommended to have a new calibration carried out by the manufacturer or an accredited laboratory every 5 years approximately. UMG 96RM-E Firmware update Battery If the device is connected to a computer via Ethernet, then the device firmware can be updated via the GridVis software. The internal clock is fed from the supply voltage. If the supply voltage fails then the clock is powered by the battery. The clock provides date and time information, for the records, min. and max. values and results, for example. Select a suitable update file (menu Extras / Update device) and the device and the new firmware will be transferred. The life expectancy of the battery is at least 5 years with a storage temperature of +45°C. The typical life expectancy of the battery is 8 to 10 years. The battery is replaced via the battery insert provided on the rear of the device. Make sure that the correct type of battery is used and correct polarity is observed when inserting the battery (positive pole faces the rear of the device; negative pole faces the front). See chapter "Changing the battery" for more information. Fig. GridVis firmware update assistant C Firmware may NOT be updated via the RS485 interface. 85 UMG 96RM-E Battery monitoring function The device indicates the condition of the battery via the "EEE" symbol followed by "bAt" and the status number. Depending on the status number a confirmation of the information by the operator may be required. It is recommended that the battery be replaced. Fault message symbol Battery fault status Fault number 86 Status EEE bAt 321 Status description • Battery capacity is <85% • Operator confirmation required • Message appears weekly after confirmation • Battery should be replaced EEE bAt 322 • Battery capacity is <75% • Battery capacity is too low • Can only be detected after resumption of mains power • Battery should be replaced EEE bAt 330 • Battery capacity OK • Message can be acknowledged • Clock is stopped and must be set EEE bAt 331 • Battery capacity is <85% • Clock is stopped and must be set • Operator confirmation required • Message appears weekly after confirmation • Battery should be replaced EEE bAt 332 • Battery capacity is <75% • Clock is stopped and must be set • Operator confirmation required • Message appears daily after confirmation • Battery should be replaced UMG 96RM-E Replacing the battery If the battery capacity is shown as < 75 %, we recommend that the battery be replaced. Procedure 1. Disconnect system and device from power supply before beginning work. 2. Discharge any electrostatic charge in your body, e. g. by touching an earthed cabinet or metal part (radiator) connected to the earth of the building. 3. Remove the battery from the battery compartment, —e.g. using long-nose pliers—. The device does not need to be opened to do this as the battery compartment can be accessed from the outside (see figure on the right). 4. Make sure that the polarity is as shown on the insertion opening of the battery compartment and slide the replacement battery into the battery compartment. For this, use a battery compliant with the description in the technical data. The battery must fulfil the safety requirements of UL1642. Otherwise, there is a risk of combustion or explosion. 5. Dispose of the old battery according to the legal regulations. 6. Start up the system and the device again and check the functionality of the UMG 96-RM. Set the date and time. Fig. Battery insertion on the rear m c m Grease or dirt on the contact surfaces form a transfer resistance that will shorten the life of the battery. Only touch the battery at the edges. Dangerous voltage! Danger to life or risk of serious injury. Disconnect system and device from power supply before beginning work. Make sure that the correct type of battery is used and observe correct polarity when changing it. 87 UMG 96RM-E Error/warning messages Warnings The UMG 96RM-E can display four different error messages: Warnings are minor errors that can be acknowledged by buttons 1 or 2. The measured values continue to be retrieved and displayed. This error is displayed after each voltage return. • • • • warnings, clock/battery errors, fatal errors and overranges. In the case of warnings and fatal errors, the error message is followed by the "EEE" symbol and an error number. Fig. Warning message with number 500 (mains frequency) The three-digit error number consists of the error description and - if set from the UMG 96RM - one or more error causes. Symbol for a error message Fault number Fig. Error message 88 Errors EEE 500 Error description The mains frequency could not be determined. Possible causes: The voltage at L1 is too small. The mains frequency does not range between 45 and 65Hz. Remedy: Check the mains frequency. Select fixed frequency on the device. UMG 96RM-E Clock/battery errors Clock or battery errors are displayed together with the "EEE" symbol followed by "bAt" and a status number. For a more detailed description please refer to "Baterry control function" and "Replacing the battery". Fig. Clock / battery error number 330 (clock does not run and has to be set. Major errors When a major error occurs, the device must be sent to the manufacturer's service center for inspection and adjustment. Errors EEE 910 Error description Error while reading the calibration. Internal causes: The UMG 96RM-E sometimes determines the cause of a major internal error with the following error code. Errors 0x01 0x02 0x04 0x08 Error description EEPROM does not respond. Address overrange. Checksum error. Error in the internal I2C bus. Example, error message 911: The error number consists of major e rror 910 and internal error cause 0x01. In this example an error occurred while reading the calibration data from EEPROM. The device has to be returned to the manufacturer for inspection and adjustment. 89 UMG 96RM-E Overranges Overranges are displayed as long as they exist and cannot be acknowledged. An overrange exists if at least one of the four voltage or current measurement inputs lies outside their specified measuring range. The "upwards" arrow indicates the phase where the overrrange occured. The appropriate error message for current path I4 is generated as shown below. The “V” and “A” symbols indicate whether the overrange occurred in the current or in the voltage path. Examples A = current path Fig.: Indication of the overrange in the current path of phase 2 (l2). V = voltage path A = current path V = voltage path Indication of the phase (L1/ L2/L3) with overrange. The current phase l4 overranges occur as shown in the figure below. Overrange limits: I UL-N 90 = 7 Aeff = 300 Vrms Fig.: Indication of the overrange in voltage path L3. Fig.: Indication of the overrange in current path l4 UMG 96RM-E Parameter overrange A detailed description of the error is coded in the parameter overrange (Addr. 600) in the following format: F F F Phase 1: 1 1 Phase 2: 2 2 Phase 3: 4 4 Phase 4 (I4): 8 8 U L-N 0x F Current: F F F F Example: Error in phase 2 in the current path: 0xF2FFFFFF Example: Error in phase 3 in the voltage path UL-N: 0xFFF4FFFF 91 UMG 96RM-E Procedure in the event of faults Possible fault Cause Remedy No display External fusing for the power supply voltage has tripped. Replace fuse. No current display Measurement voltage is not connected. Connect the measuring-circuit voltage. Measurement current is not connected. Connect measuring-circuit current. Current measurement in the wrong phase. Check connection and correct if necessary. Current transformer factor is incorrectly programmed. Read out and program the current transformer transformation ratio at the current transformer. Current displayed is too large or too small. The current peak value at the measurement input Install current transformer with a larger was exceeded by harmonic components. transformation ratio. The current at the measurement input fell short of. Install current transformer with a suitable transformation ratio. Voltage displayed is too large or too small. Measurement in the wrong phase. Check connection and correct if necessary. Voltage transformer incorrectly programmed. Read out and program the voltage transformer transformation ratio at the voltage transformer. Voltage displayed is too small. Overrange. Install voltage transformers. The peak voltage value at the measurement input Caution! Ensure the measurement inputs are not has been exceeded by harmonic components. overloaded. Phase shift ind/cap. A current path is assigned to the wrong voltage path. Effective power, consumption/supply At least one current transformer connection reversed. is mixed up/reversed. A current path is assigned to the wrong voltage path. 92 Check connection and correct if necessary. Check connection and correct if necessary. Check connection and correct if necessary. UMG 96RM-E Possible fault Effective power too large or too small. An output is not responding. Cause Read out and program the current transformer transformation ratio at the current transformer The current path is assigned to the wrong voltage path. Check connection and correct if necessary. The programmed voltage transformer transformation ratio is incorrect. Read out and program the voltage transformer transformation ratio at the voltage transformer. The output was incorrectly programmed. Check the settings and correct if necessary. The output was incorrectly connected. Check connection and correct if necessary. "EEE" in the display See error messages. "EEE bAt" in the display Battery capacity is too low No connection with the device. RS485 - Device address is incorrect. - Different bus speeds (Baud rate). - Wrong protocol. - Termination missing. Ethernet - IP address is incorrect. - Incorrect addressing mode Device still does not work despite the above measures. Remedy The programmed current transformer transformation ratio is incorrect. Device defective. See "Battery control function" and "Replacing the battery" - Adjust the device address. - Adjust speed (baud rate). - Select the correct protocol. - Close bus with termination resistor. - Adjust IP address at the device. - Adjust the IP address assignment mode Send the device to the manufacturer for inspection and testing along with an accurate fault description. 93 UMG 96RM-E Technical data General information Net weight (with attached connectors) approx. 370g Packaging weight (including accessories) approx. 950g Battery Lithium battery CR2032, 3V (approval i.a.w. UL 1642) Service life of background lighting 40000h (after this period of time the background lighting efficiency will reduce by approx. 50 %) Transport and storage The following information applies to devices which are transported or stored in the original packaging. Free fall 1m Temperature K55 (-25°C to +70°C) Relative humidity 0 to 90 % RH Ambient conditions during operation The UMG 96RM is intended for weather-protected, stationary use. Protection class II i.a.w. IEC 60536 (VDE 0106, Part 1). Operating temperature range K55 (-10°C .. +55°C) Relative humidity 0 to 75 % RH Operating altitude 0 .. 2000m above sea level Degree of pollution 2 Mounting position vertical Ventilation Forced ventilation is not required. Protection against ingress of solid foreign bodies and water - Front side - Rear side - Front with seal IP40 i.a.w. EN60529 IP20 i.a.w. EN60529 IP54 i.a.w. EN60529 94 UMG 96RM-E Power supply voltage Option 230V Option 24V Nominal range 90V - 277V (50/60Hz) or DC 90V - 250V; 300V CATIII Power consumption max. 7.5VA / 4W Nominal range 24V - 90V AC / DC; 150V CATIII Power consumption max. 3.5VA / 2W Operating range +-10% of nominal range Internal fuse, not replaceable Typ T1A / 250V/277V according IEC 60127 Recommended overcurrent protection device for line protection (certified under UL) Option 230V: 6 - 16A Option 24V: 6 - 16A Recommendation for a maximum number of devices on a circuit breaker: Option 230V: Circuit breaker B6A: max. 4 devices / Circuit breaker B16A: max. 11 devices Option 24V : Circuit breaker B6A: max. 3 devices / Circuit breaker B16A: max. 9 devices 95 UMG 96RM-E Digital outputs 2 and 3 optional digital outputs, semiconductor relays, not short-circuit proof. Switching voltage max. 33V AC, 60V DC Switching current max. 50mAeff AC/DC Response time 10/12 periods + 10ms * Pulse output (energy pulse) max. 50Hz * Response time e.g. at 50Hz: 200ms + 10ms = 210 ms Digital inputs 3 optional digital inputs, semiconductor relays, not short-circuit proof. Maximum counter frequency 20Hz Input signal present 18V .. 28V DC (typical 4mA) Input signal not present 0 .. 5V DC, current less than 0.5mA 96 UMG 96RM-E Temperature measurement input 2 optional inputs. Update time 1 second Connectable sensors PT100, PT1000, KTY83, KTY84 Total burden (sensor + cable) max. 4 kOhm Sensor type Temperature range Resistor range Uncertainty in measurement KTY83 -55°C ... +175°C 500Ohm ... 2,6kOhm ± 1,5% rng KTY84 -40°C ... +300°C 350Ohm ... 2,6kOhm ± 1,5% rng PT100 -99°C ... +500°C 60Ohm ... 180Ohm ± 1,5% rng PT1000 -99°C ... +500°C 600Ohm ... 1,8kOhm ± 1,5% rng Cable length (digital inputs and outputs, temperature measurement input) Up to 30m Unshielded More than 30m Shielded 97 UMG 96RM-E Serial interface RS485 - Modbus RTU/Slave 9.6kbps, 19.2kbps, 38.4kbps, 57.6 kbps, 115.2kbps Stripping length 7mm Measuring voltage Three-phase 4-conductor systems with nominal voltages up to 277V/480V (+-10%) Three-phase 3-conductor systems, unearthed, with nominal voltages up to IT 480V (+-10%) Overvoltage category 300V CAT III Measurement surge voltage 4kV Measurement range L-N 01) .. 300Vrms (max. surge voltage 520Vrms ) Measurement range L-L 01) .. 520Vrms (max. surge voltage 900Vrms ) Resolution 0.01V Crest factor 2,45 (related to the measurement range) Impedance 4MOhm/phase Power consumption apporx. 0,1VA Sampling frequency 21.33kHz (50Hz); 25.6 kHz (60Hz) per measurement channel Frequency range of the basic oscillation - Resolution 45Hz .. 65Hz 0.01Hz The UMG 96RM-E can only detect measurements when a voltage L1-N greater than 20V eff (4-wire measurement) at voltage input V1 or a voltage L1-L2 greater 1) than 34V eff (3-wire measurement) is applied. 98 UMG 96RM-E Current measurement I1 - I4 Rated current 5A Measurement range 0 .. 6Arms Crest factor 1.98 Resolution 0.1mA (Display 0.01A) Overvoltage category 300V CAT II Measurement surge voltage 2kV Power consumption approx. 0.2 VA (Ri=5mOhm) Overload for 1 sec. 120A (sinusoidal) Sampling frequency 20kHz Residual current measurement I5 / I6 Rated current 30mArms Measurement range 0 .. 40mArms Operating current 50µA Resolution 1µA Crest factor 1.414 (related to 40mA) Burden 4 Ohm Overload for 1 sec. 5A Sustained overload 1A Overload for 20 ms 50A Residual current measurement i.a.w. IEC/TR 60755 (2008-01), Type A Type B 99 UMG 96RM-E Ethernet connection Connection RJ45 Functions Modbus gateway, embedded web server (HTTP) Protocols TCP/IP, DHCP-Client (BootP), Modbus/TCP (Port 502), ICMP (Ping), NTP, Modbus RTU over Ethernet (Port 8000), FTP, SNMP Terminal connection capacity (power supply voltage) Conductors to be connected. Only one conductor can be connected per terminal! Single core, multi-core, fine-stranded 0.2 - 2.5mm2, AWG 26 - 12 Terminal pins, core end sheath 0.2 - 2.5mm2 Tightening torque 0.4 - 0.5Nm Stripping length 7mm 100 UMG 96RM-E Terminal connection capacity (voltage and current measurement) Conductors to be connected. Only one conductor can be connected per terminal! Current Voltage Single core, multi-core, fine-stranded 0.2 - 2.5mm2, AWG 26-12 0.08 - 4.0mm2, AWG 28-12 Terminal pins, core end sheath 0.2 - 2.5mm2 0.2 - 2.5mm2 Tightening torque 0.4 - 0.5Nm 0.4 - 0.5Nm Stripping length 7mm 7mm Terminal connection capacity (residual current or temperature measurement inputs and digital inputs / outputs) Rigid/flexible 0.14 - 1.5mm2, AWG 28-16 Flexible with core end sheath without plastic sleeve 0.20 - 1.5mm2 Flexible with core end sheath with plastic sleeve 0.20 - 1.5mm2 Tightening torque 0.20 - 0.25Nm Stripping length 7mm Terminal connection capacity: serial interface Single core, multi-core, fine-stranded 0.20 - 1.5mm2 Terminal pins, core end sheath 0.20 - 1.5mm2 Tightening torque 0.20 - 0.25Nm Stripping length 7mm 101 UMG 96RM-E Function parameters Function Symbol Precision class Measurement range Display range Total effective power P 0.55) (IEC61557-12) 0 .. 5.4 kW 0 W .. 999 GW * Total reactive power QA, Qv 1(IEC61557-12) 0 .. 5.4 kvar 0 varh .. 999 Gvar * Total apparent power SA, Sv 0.55) (IEC61557-12) 0 .. 5.4 kVA 0 VA .. 999 GVA * Total active energy Ea 0.5S5) 6)(IEC61557-12) 0 .. 5.4 kWh 0 Wh .. 999 GWh * Total reactive power ErA, ErV 1(IEC61557-12) 0 .. 5.4 kvarh 0 varh .. 999 Gvarh * Total apparent energy EapA, EapV 0.55) (IEC61557-12) 0 .. 5.4 kVAh 0 VAh .. 999 GVAh * Frequency f 0.05(IEC61557-12) 45 .. 65Hz 45.00Hz .. 65.00Hz Phase current I1 - I3 I 0.2(IEC61557-12) 0 .. 6 Arms 0 A .. 999 kA Measured neutral conductor current l4 IN 1(IEC61557-12) 0 .. 6 Arms 0 A .. 999 kA Residual currents I5, I6 IRes 1(IEC61557-12) 0 .. 30 mArms 0 A .. 999 kA Computed neutral conductor current INc 1.0(IEC61557-12) 0.03 .. 25 A 0.03 A .. 999 kA Voltage U L-N 0.2(IEC61557-12) 10 .. 300 Vrms 0 V .. 999 kV Voltage U L-L 0.2(IEC61557-12) 18 .. 520 Vrms 0 V .. 999 kV Power factor PFA, PFV 0.5(IEC61557-12) 0.00 .. 1.00 0.00 .. 1.00 Short-term flicker, long-term flicker Pst, Plt - - - Voltage drops (L-N) Udip - - - Voltage increases (L-N) Uswl - - - Transient overvoltages Utr - - - Voltage drops Unit - - - Voltage unbalance (L-N) 1) Unba - - - Voltage unbalance (L-N) 2) Unb - - - Voltage harmonics Uh Kl. 1 up to 2.5 kHz 0 V .. 999 kV THD of the voltage 3) THDu 1.0(IEC61557-12) up to 2.5 kHz 0 % .. 999 % THD of the voltage 4) THD-Ru - - - 102 (IEC61000-4-7) UMG 96RM-E Function Symbol Precision class Measurement range Display range Current harmonics Ih Kl. 1 up to 2.5 kHz 0 A .. 999 kA THD of the current 3) THDi 1.0(IEC61557-12) up to 2.5 kHz 0 % .. 999 % THD of the current 4) THD-Ri - - - Mains signal voltage MSV - - 1) 2) 3) 4) Referred to amplitude. Referred to phase and amplitude. Referred to mains frequency. Referred to root mean square value. (IEC61000-4-7) 5) Accuracy class 0.5 with ../5 A transformer. Accuracy class 1 with ../1 A transformer. 6) Accuracy class 0.5S according IEC62053-22 * The display returns to 0 W when the maximum total energy values are reached. 103 UMG 96RM-E Parameter and modbus address list The following excerpt of the parameter list provides the settings that are necessary for the proper operation of the UMG 96RM-E, such as current transformer and device addresses. The valuesin the parameter list can be set and read. C The excerpt of the measured value list includes the measured and calculated values, output status data and recorded values to be read. C Table 1 – Parameter list Address format RD/WR Unit Note A complete overview of the parameters and measured values as well as explanations regarding the selected measured values is filed in the document “Modbus Address List” on the CD or Internet. The addresses contained in the description can be adjusted directly on the device in the range from 0 to 800. The address range above 1000 can only be processed via modbus! Adjustment range Default (*1) 0 SHORT RD/WR - Device address 0..255 1 1 SHORT RD/WR kbps Baud rate (0=9.6kbps, 1=19.2kbps, 0..7 4 2=38.4kbps, 3= 57.6kbps (5..7 only for 4=115.2kbps) internal use) 2 SHORT RD/WR - Modbus Master 0, 1 0 0=Slave, 1=Master (if Ethernet is provided) 3 SHORT RD/WR - Stoppbits 0..3 0 0 = 1 Bit, none parity 1 = 2 Bits, none parity 2 = 1 Bit, even parity 3 = 1 Bit, uneven parity 10 FLOAT RD/WR A Current transformer I1, primary 0..1000000 (*2)5 12 FLOAT RD/WR A Current transformer l1, sec. 1..5 5 (*1) (*2) 104 Values 0 and 248 through 255 are reserved and may not be used. The adjustable value of 0 does not produce any useful work values and must not be used. UMG 96RM-E Address format RD/WR Unit Note 14 FLOAT RD/WR V Voltage transformer V1, prim. 16 FLOAT RD/WR V Voltage transformer V1, sec. 18 FLOAT RD/WR A Current transformer I2, primary 20 FLOAT RD/WR A Current transformer I2, sec. 22 FLOAT RD/WR V Voltage transformer V2, prim. 24 FLOAT RD/WR V Voltage transformer V2, sec. 26 FLOAT RD/WR A Current transformer I3, primary 28 FLOAT RD/WR A Current transformer I3, sec. 30 FLOAT RD/WR V Voltage transformer V3, prim. 32 FLOAT RD/WR V Voltage transformer V3, sec. 34 SHORT RD/WR Hz Frequency estimation 0=Auto, 45 .. 65=Hz 35 SHORT RD/WR - Display contrast 0 (low), 9 (high) 36 SHORT RD/WR - Background lighting 0 (dark), 9 (bright) 37 SHORT RD/WR - Display profile 0=preset display profile 1=preset display profile 2=preset display profile 3=customizable display profile 38 SHORT RD/WR - Display rotation profile 0..2=preset display rotation profile 3=customizable display rotation profile 39 SHORT RD/WR s Rotation time 40 SHORT RD/WR - Reporting time, I 41 SHORT RD/WR - Reporting time, P 42 SHORT RD/WR - Reporting time, U Adjustment range Default 0..1000000 (*2)400 100, 400 400 0..1000000 (*2)5 1..5 5 0..1000000 400 100, 400 400 0..1000000 5 1..5 5 0..1000000 400 100, 400 400 0, 45 .. 65 0 0 .. 9 5 0 .. 9 6 0 .. 3 0 0 .. 3 0 0 .. 60 0 .. 8* 0 .. 8* 0 .. 8* 0 6 6 6 * 0 = 5sec.; 1 = 10sec.; 2 = 15sec.; 3 = 30sec.; 4 = 1min.; 5 = 5min.; 6 = 8min.; 7 = 10min.; 8 = 15min. 105 UMG 96RM-E Address format RD/WR Unit 45 USHORT RD/WR mA 50 SHORT RD/WR - Note Adjustment range Default Response threshold of current measuring I1 .. I3 Password 0 .. 200 5 0 .. 999 0 (No password) 0..32000 874 0..32000 882 100 SHORT RD/WR - Measured value address, Digital output 1 101 SHORT RD/WR - Measured value address, Digital output 2 102 FLOAT RD/WR Wh Pulse value, Digital output 1 104 FLOAT RD/WR Wh Pulse value, Digital output 2 106 SHORT RD/WR 10ms Min. pulse length (1=10ms) Digital output 1/2 206 SHORT RD/WR s “Drag indicator” period duration 207 SHORT RD/WR s “Drag indicator” capture time 208 SHORT RD/WR - Config. Digital input 1 0= internal synchronisation 1= external synchronisation (NO) 2= external synchronisation (NC) 500 SHORT RD/WR - Connector pin assignment, I L1 501 SHORT RD/WR - Connector pin assignment, I L2 502 SHORT RD/WR - Connector pin assignment, I L3 503 SHORT RD/WR - Connector pin assignment, U L1 504 SHORT RD/WR - Connector pin assignment, U L2 505 SHORT RD/WR - Connector pin assignment, U L3 506 SHORT RD/WR - Min- und Reset max. values 507 SHORT RD/WR - Reset energy meter 508 SHORT RD/WR - force EEPROM descr. -1000000..+1000000 1000 -1000000..+1000000 1000 1..1000 300..3600 1..20 0 .. 2 5 (=50ms) 900 10 0 -3..0..+3 1)+1 -3..0..+3 1)+2 -3..0..+3 1)+3 0..3 1)1 0..3 1)2 0..3 1)3 0..1 0 0..1 0 0..1 0 Note: Energy values and min-max values are recorded into the EEPROM every 5 minutes. 0 = No measurement of the current or voltage path. The setting 8 is equal setting 0. 1) 106 2) UMG 96RM-E Address format RD/WR Unit 509 SHORT RD/WR - 510 SHORT RD/WR - 511 SHORT RD/WR - Note Adjustment range Voltage connection diagram Current connection diagram Relevant voltage for THD and FFT 0..8 2)0 0..8 0 0, 1 The THD and FFT voltages can be displayed as L-N or L-L values. 0=LN, 1=LL 512 513 514 515 516 517 SHORT SHORT SHORT SHORT SHORT SHORT RD/WR RD/WR RD/WR RD/WR RD/WR RD/WR - - - - - - Year Month Day Hour Minute Second 0..99 0..12 0..31 0..24 0..59 0..59 600 750 754 756 UINT RD/WR - Overrange 0..0xFFFFFFFF SHORT SERNR SERNR RD RD RD - - - Software release Serial number Production no. 746 SHORT RD/WR s 747 SHORT RD/WR s C Period of time after which the backlight will switch to standby Brightness of the standby backlight 60 .. 9999 0 .. 9 Default 0 900 0 Only the first 3 digits (###) of a value are displayed on the screen. Values greater than 1000 are marked with "k". Example: 003k = 3000 107 UMG 96RM-E Table 2 - Modbus address list (frequently needed measured values) C Modbus The addresses contained in the description can be adjusted directly on the device in the range from 0 to 800. The address range 800-999 is available for programming comparators on the device. The addresses above 1000 can only be processed via modbus! C A complete overview of the parameters and measured values as well as explanations regarding the selected measured values is filed in the document “Modbus Address List” on the CD or Internet. Address address via Display Format RD/WR Unit Note 19000 19002 19004 19006 19008 19010 19012 19014 19016 19018 19020 19022 19024 19026 19028 19030 808 810 812 814 816 818 860 862 864 866 868 870 872 874 884 886 float float float float float float float float float float float float float float float float RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD V V V V V V A A A A W W W W VA VA Voltage L1-N Voltage L2-N Voltage L3-N Voltage L1-L2 Voltage L2-L3 Voltage L3-L1 Current, L1 Current, L2 Current, L3 Vector sum; IN=I1+I2+I3 Real power L1 Real power L2 Real power L3 Sum; Psum3=P1+P2+P3 Apparent power S L1 Apparent power S L2 108 UMG 96RM-E ModbusAddress address via Display Format RD/WR Unit Note 19032 19034 19036 19038 19040 19042 19044 19046 19048 19050 19052 19054 19056 19058 19060 19062 19064 19066 19068 19070 19072 19074 19076 19078 19080 19082 19084 19086 19088 19090 19092 float float float float float float float float float float float float float float float float float float float float float float float float float float float float float float float RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD VA VA var var var var - - - Hz - Wh Wh Wh Wh Wh Wh Wh Wh Wh Wh Wh Wh VAh VAh VAh VAh varh varh varh varh Apparent power S L3 Sum; Ssum3=S1+S2+S3 Fund. reactive power (mains frequ.) Q L1 Fund. reactive power (mains frequ.) Q L2 Fund. reactive power (mains frequ.) Q L3 Sum; Qsum3=Q1+Q2+Q3 Fund.power factor, CosPhi; U L1-N IL1 Fund.power factor, CosPhi; U L2-N IL2 Fund.power factor, CosPhi; U L3-N IL3 Measured frequency Rotation field; 1=right, 0=none, -1=left Real energy L1 Real energy L2 Real energy L3 Real energy L1..L3 Real energy L1, consumed Real energy L2, consumed Real energy L3, consumed Real energy L1..L3, consumed, rate 1 Real energy L1, delivered Real energy L2, delivered Real energy L3, delivered Real energy L1..L3, delivered Apparent energy L1 Apparent energy L2 Apparent energy L3 Apparent energy L1..L3 Reactive energy L1 Reactive energy L2 Reactive energy L3 Reactive energy L1..L3 888 890 876 878 880 882 820 822 824 800 - - - - - - - - - - - - - - - - - - - - - 109 UMG 96RM-E ModbusAddress address via Display Format RD/WR Unit Note 19094 19096 19098 19100 19102 19104 19106 19108 19110 19112 19114 19116 19118 19120 float float float float float float float float float float float float float float RD RD RD RD RD RD RD RD RD RD RD RD RD RD varh varh varh varh varh varh varh varh % % % % % % Reactive energy, inductive, L1 Reactive energy, inductive, L2 Reactive energy, inductive, L3 Reactive energy L1..L3, ind. Reactive energy, capacitive, L1 Reactive energy, capacitive, L2 Reactive energy, capacitive, L3 Reactive energy L1..L3, cap. Harmonic, THD, U L1-N Harmonic, THD, U L2-N Harmonic, THD, U L3-N Harmonic, THD, I L1 Harmonic, THD, I L2 Harmonic, THD, I L3 ModbusAddress address via display Format RD/WR Unit Note 20006 20008 20010 20012 20014 20016 20018 float float float float float float float RD/WR A RD/WRA RD/WRA RD/WRA RD/WRA RD/WRA RD/WRA 110 - - - - - - - - 836 838 840 908 910 912 - - - - - - - Adjustment range Default TDD I4, full-load current 0...1000000 current transformer I4, primary0...1000000 current transformer I4, secondary1..5 current transformer I5, primary0..1000000 current transformer I5, secondary0,001...5 current transformer I6, primary0...1000000 current transformer I6, secondary0,001...5 150 5 5 5 5 5 5 UMG 96RM-E Number formats Type Size Minimum Maximum short 16 bit -215 215 -1 ushort 16 bit 0 216 -1 int 32 bit -2 231 -1 uint 32 bit 0 232 -1 float 32 bit IEEE 754 IEEE 754 31 C Notes on saving measurement values and configuration data: • The following measurement values are saved at least every 5 minutes: • Comparator timer • S0 meter readings • Minimum / maximum / mean values • Energy values • Configuration data is saved immediately! 111 UMG 96RM-E Dimension diagrams All dimensions provided in mm Rear view View from below □ 91,5 110,5 112 UMG 96RM-E Side view Cut-out size ca. 90 104 91,5 6 92+0,8 92+0,8 (depth without connector) 96 72 57 78 113 UMG 96RM-E Measured value displays overview A01 B01 C01 D01 Measured values L1-N voltage L2-N voltage L3-N voltage Mean values L1-N voltage L2-N voltage L3-N voltage Maximum values L1-N voltage L2-N voltage L3-N voltage Minimum values L1-N voltage L2-N voltage L3-N voltage A02 Measured values L1-L2 voltage L2-L3 voltage L3-L1 voltage B02 Mean values L1-L2 voltage L2-L3 voltage L3-L1 voltage C02 D02 Maximum values L1-L2 voltage L2-L3 voltage L3-L1 voltage Minimum values L1-L2 voltage L2-L3 voltage L3-L1 voltage A03 B03 C03 D03 Measured values L1 current L2 current L3 current Mean values L1 current L2 current L3 current Maximum values L1 current L2 current L3 current Max. values (mean value) L1 current L2 current L3 current A04 B04 C04 D04 Measured value Sum Current in the N line Mean value Sum Current in the N line Maximum value Measured value sum Current in the N line Maximum values Sum mean value Current in the N line A05 B05 C05 Measured values L1 active power L2 active power L3 active power Mean value L1 active power L2 active power L3 active power Maximum values L1 active power L2 active power L3 active power A06 B06 C06 D06 Measured value Sum Active power Mean value Sum Active power Maximum value Sum Active power Maximum value Sum Active power mean value A07 B07 C07 Measured values L1 apparent power L2 apparent power L3 apparent power Mean values L1 apparent power L2 apparent power L3 apparent power Maximum values L1 apparent power L2 apparent power L3 apparent power 114 UMG 96RM-E A08 B08 C08 Measured value Sum Apparent power Mean value Sum Apparent power Maximum value Sum Apparent power A09 B09 C09 Measured values L1 reactive power L2 reactive power L3 reactive power Mean values L1 reactive power L2 reactive power L3 reactive power Maximum values (ind) L1 reactive power L2 reactive power L3 reactive power A10 B10 C10 Measured value Sum of reactive power Mean value Sum of reactive power Maximum value (ind) Sum of reactive power A11 B11 C11 Measured value Distortion factor (THD) U L1 Measured value Distortion factor (THD) U L2 Measured value Distortion factor (THD) U L3 A12 B12 C12 Measured value Distortion factor (THD) I L1 Measured value Distortion factor (THD) I L2 Measured value Distortion factor (THD) I L3 A13 B13 C13 Maximum value Distortion factor (THD) U L1 Maximum value Distortion factor (THD) U L2 Maximum value Distortion factor (THD) U L3 A14 B14 C14 Maximum value Distortion factor (THD) I L1 Maximum value Distortion factor (THD) I L2 Maximum value Distortion factor (THD) I L3 115 UMG 96RM-E A15 Measured value L1 cos(phi) L2 cos(phi) L3 cos(phi) A16 B16 Measured value Sum of cos(phi) Mean value Sum of cos(phi) A17 Measured value Frequency L1 Rotation field display A18 B18 C18 D18 E18 F18 G18 Measured value Total active energy (without a backstop) Measured value Total active energy (import) Measured value Total active energy (export) Measured value Sum Apparent energy Measured value Active energy L1 Import (tariff 1) Measured value Active energy L2 Import (tariff 1) Measured value Active energy L3 Import (tariff 1) A19 B19 C19 D19 E19 F19 Measured value (ind) Reactive energy Measured value Sum Reactive energy cap. Measured value Sum Reactive energy ind. Measured value Reactive energy L1 ind. (tariff 1) Measured value Reactive energy L2 ind. (tariff 1) Measured value Reactive energy L3 ind. (tariff 1) A20 B20 Operating hours meter 1 Comparator 1A* Total running time G20 ... Comparator 2C* Total running time ... A21 B21 H21 Measured value 1st. harmonic U L1 Measured value 3rd. harmonic U L1 Measured value 15th. harmonic U L1 Marked menus are not displayed in the factory presetting. 116 * Only the first 6 comparators are shown. UMG 96RM-E A22 B22 H22 Measured value 1st. harmonic U L2 Measured value 3rd. harmonic U L2 ... Measured value 15th. harmonic U L2 A23 B23 H23 Measured value 1st. harmonic U L3 Measured value 3rd. harmonic U L3 ... Measured value 15th. harmonic U L3 A24 B24 H24 Measured value 1st. harmonic I L1 Measured value 3rd. harmonic I L1 ... Measured value 15th. harmonic I L1 A25 B25 H25 Measured value 1st. harmonic I L2 Measured value 3rd. harmonic I L2 ... Measured value 15th. harmonic I L2 ... Measured value 15th. harmonic I L3 A26 Measured value 1st. harmonic I L3 B26 Measured value 3rd. harmonic I L3 H26 A27 B27 H27 Maximum value 1st. harmonic U L1 Maximum value 3rd. harmonic U L1 ... Maximum value 15th. harmonic U L1 ... A28 B28 H28 Maximum value 1st. harmonic U L2 Maximum value 3rd. harmonic U L2 Maximum value 15th. harmonic U L2 Marked menus are not displayed in the factory presetting. 117 UMG 96RM-E A29 B29 H29 Maximum value 1st. harmonic U L3 Maximum value 3rd. harmonic U L3 ... Maximum value 15th. harmonic U L3 A30 B30 H30 Maximum value 1st. harmonic I L1 Maximum value 3rd. harmonic I L1 ... Maximum value 15th. harmonic I L1 A31 B31 H31 Maximum value 1st. harmonic I L2 Maximum value 3rd. harmonic I L2 ... Maximum value 15th. harmonic I L2 A32 B32 H32 Maximum value 1st. harmonic I L3 Maximum value 3rd. harmonic I L3 ... Maximum value 15th. harmonic I L3 A33 B33 C33 D33 Maximum values L4 current Max. values (mean value) L4 current Measured values L4 current Mean values L4 current A34 B34 C34 D34 Measured values L5 current Mean values L5 current Maximum values L5 current Max. values (mean value) L5 current A35 B35 C35 D35 Measured values L6 current Mean values L6 current Maximum values L6 current Max. values (mean value) L6 current Marked menus are not displayed in the factory presetting. 118 Even and odd harmonics up to the 40th order can be called up via the GridVis software and can be viewed in the software. UMG 96RM-E 119 UMG 96RM-E Connection example 1 (with residual current measurement IPE / IRES) + = S1 S2 S3 IDIFF IPE B - 24V = DC + = A + 13 K3 K2 14 15 Group 11 Gruppe 28 29 0-30 mA K5 K4 30 0-30 mA 4) 31 32 Group 2 Gruppe 2 4) 33 34 I5 35 36 16 B 37 I6 RS485 Analog inputs Analog-Eingänge Digital inputs/outputs Digital-Eingänge/Ausgänge 17 A Ethernet 10/100Base-T K1 UMG 96RM-E (RCM) Power supply Versorgungsvoltage spannung Measuring voltage Spannungsmessung N/- L/+ V1 V2 V3 VN 1 3 4 5 6 2 1) 2) 2) Current measurement Strommessung S2 S1 S2 3) 2) S1 S2 3) Consumer Verbraucher S2 120 S1 S2 I4 S1 19 18 3) S2 S2 3) UL / IEC approved overcurrent protection system (6A Char. B) 2) UL / IEC approved overcurrent protection system (10A Class CC / Char. C) 3) Jumpers (external) 4) Jumpers between connectors 32-33 and 35-36 are only required from hardware-release 104! 1) S1 L1 S1 L2 S1 L3 S2 230V/400V 50Hz PC RJ45 - - S1 N UMG 96RM-E Connection example 2 (with temperature and residual current measurement) + = S2 S3 IDIFF B PT100 = + K1 K3 K2 14 15 28 4) 29 30 31 Group 2 Gruppe Group 1 Gruppe A 0-30 mA K5 K4 32 Digital inputs/outputs Digital-Eingänge/Ausgänge 33 34 I5 35 36 16 B 37 I6 17 A RS485 Analog inputs Analog-Eingänge UMG 96RM-E (RCM) Power supply Versorgungsvoltage spannung Measuring voltage Spannungsmessung N/- L/+ V1 V2 V3 VN 1 3 4 5 6 2 1) 2) 2) Current measurement Strommessung S2 S1 S2 3) 2) S1 S2 3) Consumer Verbraucher S2 S1 S2 I4 S1 19 18 3) S2 S2 UL / IEC approved overcurrent protection system (6A Char. B) 2) UL / IEC approved overcurrent protection system (10A Class CC / Char. C) 3) Jumpers (external) 4) Jumpers between connectors 35-36 are only required from hardware-release 104! 1) 3) S1 L1 S1 L2 S1 L3 S2 230V/400V 50Hz PC RJ45 24V = DC + 13 S1 - Ethernet 10/100Base-T - - S1 N 121 UMG 96RM-E Basic functions quick guide Adjusting current transformer, primary current Adjusting the current transformer Switch to the programming mode: • Press button 1 and 2 simultaneously for around 1 second to switch to the programming mode. The symbols for the programming mode PRG and the current transformer mode CT appear on the display. • Press button 1 to confirm the selection. • The first digit of the input field for the primary current is flashing. Adjusting the primary current • Press button 2 to change the flashing digit. • Press button 1 to select the next digit to be changed. The selected digit to be changed is flashing. If the entire number is flashing, press button 2 to move the decimal point. Adjusting the secondary current • Only 1A or 5A can be set as secondary current. • Press button 1 to select the secondary current. • Press button 2 to change the flashing digit. Exit programming mode • Press button 1 and 2 simultaneously for around 1 second to switch to the display mode. Display Programming mode 122 Adjusting current transformer, secondary current Current transformer symbol (in the programming mode only) View measured values Switch to the display mode: • If you are still in the programming mode (PRG and CT icons displayed on the screen), press button 1 and 2 simultaneously for around 1 second to switch to the display mode. • A measured value display (e.g. voltage) appears Button controls • Press button 2 to change the measured value display for current, voltage, power, etc. • Press button 1 to change the mean values, max. values etc. associated with the measured value. UMG 96RM-E TCP/IP addressing quick guide Manual TCP/IP settings Switch to the programming mode: • Press button 1 and 2 simultaneously for around 1 second to switch to the programming mode. The symbols for the programming mode PRG and the current transformer mode CT appear on the display. Adjust the TCP/IP address (Adr.) • Press button 2 to select "Adr" • Press button 1 to enable the first digit (byte 0) of the address (digit is flashing). Press button 2 to set the digit. • Press button 1 to select the next digit (flashing) and set the desired digit by pressing button 2. • If byte is set to 0, the address can be set from 1 to 3 by pressing button 1. Then the display jumps back to Byte 0 (no digit is flashing). Subnet mask (SUb) • Press button 2 to select the subnet mask and set it in a manner similar to adjusting the address by pressing button 1 and 2. Adjusting the gateway address (GAt) • Use button 2 and 1 to set the gateway in a manner similar to adjusting the address. Exit programming mode • Press button 1 and 2 simultaneously to exit the mode or wait 60 seconds. Description Byte identification (e.g. byte 0) of the address Address data, byte 0 Fig. TCP/IP address, byte 1 A TCP / IP address consists of 4 bytes with the following structure: Byte 0 Byte 1 Byte 2 Byte 3 xxx.xxx.xxx.xxx Enable dynamic IP allocation (dyn) Device/gateway address and subnet mask are assigned by a DHCP server and enable automatic integration of the device into the existing mains. • When in programming mode, press button 2 repeatedly to display the tab labelled "dYn IP". • Press button 1 to enable the parameter "on" or "oFF" (parameter is flashing). Press button 2 to set the desired status and press button 1 to confirm the selection. • Exit programming mode. 123 UMG 96RM-E 124
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement