About this Product

Thank you for your purchase of Ikelite equipment. Please read this instruction manual completely before attempting to operate or dive with this product. Please visit ikelite.com to register your product to receive information on any updates, notices, or recalls pertaining to your equipment.

Included in the Box

Housing

Internal camera mounting tray 9569.01

Main o-ring 0110

Dome port 5516.15

Zoom sleeve 5509.19

Neoprene port cover 0200.1

Waterproof bulkhead cap 9104.5

Spare port o-ring 0132.36

Spare set of 3 port thumb screws 9249.6

Silicone lubricant 1cc tube 0184.1

2

Important Notices

»

Never leave a housing in a rinse tank, even if it is the only system in the tank. The vast majority of catastrophic floods happen when the user walks away from a housing while it is in the rinse tank.

»

To prevent salt build-up and sticking controls, submerge the empty housing in clean, freshwater. Operate the controls several times each while underwater to flush out any residue.

»

Do not use alcohol, cleaning agents, spray lubricants, Rain-X, or other solvents on the housing or lens port. Use of an incompatible chemical compound can damage the plastic and o-rings, and may result in leaking.

3

Contents

Product Registration

About this Product

Included in the Box

Important Notices

Getting to Know Your Housing

Getting to Know Your Housing - cont.

Accessory Port

Setting Up Your Camera

Pre-Installation Checklist

Setting Up Your Housing

Opening the Housing

Inserting the Camera

Attaching the Hotshoe

Closing the Housing

Lens Port Options

5516.15 Dome Port (included with housing)

5516.50 Flat Port (optional)

Attaching / Removing the Lens Port

OPTIONAL Tray & Handle(s)

Setting Up An External Strobe

About Sync Cords

Attaching a Sync Cord

Conversion Circuitry

Final Check

Entering the Water

Spare Parts

Maintenance

Post-Dive

Travel and Storage

4

15

15

15

16

17

17

11

11

12

12

14

18

18

18

19

9

10

10

8

8

7

7

2

3

5

6

7

1

2

Troubleshooting

Limited Warranty

Service and Repairs

Contact Us

Getting to Know Your Housing

Shutter

Button

Zoom

Control

Mode Dial

ISO Speed

External Strobe

Connector and Cap

19

22

23

24

Lid Snap

External Tray

Mount

Dome Port

Accessory

Port

Lens

Release

Button

5

Getting to Know Your Housing - cont.

Power/Movie Switch

Optical

Viewfinder

MENU

INFO

Av

13

MENU

INFO

LEFT Cross Key

Av

13

INFO Button

Rear Dial

AF Point/Magnify

AE/FE Lock

UP Cross Key

RIGHT Cross Key

SET Quick Control

6

Accessory Port

Your housing features one 1/2-20 threaded Accessory Port which may be used for attachment of factory optional or aftermarket housing accessories. Visit ikelite.com for an updated list of factory optional accessories.

Use the following steps to replace an Accessory Port Hole Plug with an accessory fitting:

1. Remove the Hole Plug using an 11/16 inch open end wrench.

2. Check the accessory fitting o-ring sealing area. If an o-ring is not present, use the Hole Plug o-ring. Lightly lubricate o-ring with

Ikelite Lubricant. Use ONLY Ikelite lubricant. Other manufacturer lubricants can cause the o-ring to swell. Check o-ring and o-ring sealing area. Both should be clean and free of hair, sand, or other debris.

3. Carefully screw in and tighten accessory fitting. The accessory port features a 1/2-20 threaded hole. Make sure your fitting is the same thread pattern. DO NOT cross-thread. DO NOT overtighten.

NOTICE: Your Ikelite housing warranty DOES NOT extend to cover the attachment of aftermarket housing accessories by 3rd parties. Warranty DOES cover factory optional accessories attached by certified Ikelite service technicians.

Setting Up Your Camera

Pre-Installation Checklist

1. Insert a fully charged camera battery.

2. Insert a properly formatted memory card.

3. REMOVE eyecup from camera’s optical viewfinder.

7

4. Set Mode Dial to “M” Manual Mode.

5. Set shutter speed to 1/125th second and aperture to F8. Set aperture to F22 for macro (close-up) photography.

6. Set Red-Eye Reduction to “Disable.”

7. In Flash Control, set Flash Firing to “Enable.”

8. Set LCD Auto Off to “Disable.”

9. Set Touch Control to “Disable.”

NOTE: These initial camera settings may change based on your shooting conditions. All other camera functions not mentioned should be set to the user’s preference.

Setting Up Your Housing

Opening the Housing

1. Push the lid snap lock forward and start to lift the curved end away from the housing.

Lid Snap Lock

8

2. Lid snaps are designed to provide enough force to compress the o-ring for a proper seal. Keep firm pressure against the lid snap while lifting it away.

3. Repeat with remaining lid snap.

4. Remove the housing back.

Inserting the Camera

1. Remove any lanyard or neck strap which may be attached to the camera.

2. Remove the camera Mounting Tray from the housing.

3. Line the mounting screw up with the camera’s tripod socket. Use a coin or flat head screwdriver to tighten the mounting plate to the camera.

Camera tripod socket

Mounting screw

1/4-20

Tripod

Mounting

Hole

Mounting

Bolt

Mounting

Tray

4. Pull out on the housing control knobs to move them out of the way.

9

5. Insert the mounting plate into the slot on the inside bottom of the housing. Push the camera all of the way forward until the back of the mounting plate is flush with the back of the housing mount.

Attaching the Hotshoe

Slide Hotshoe into Camera Hotshoe Mount until it stops.

NOTE: Hotshoe must be all the way forward in the Camera Hotshoe

Mount to ensure a good electrical connection.

Hotshoe

Camera Hotshoe Mount

Closing the Housing

1. Make sure the o-ring is clean and in its proper location on the back of the housing. The main housing o-ring does not require lubricant to make a seal.

2. Place the back onto the housing front.

3. Make sure no controls or wires are interfering with the o-ring or the back of the housing.

10

4. Place each lid snap into the corresponding hook on the housing back.

5. Push the lid snaps towards the housing until they are flat against the housing and the lock has engaged. Close opposing lid snaps at the same time.

Lid Hook Housing Back

Main O-ring

Lid Snap

6. Check the o-ring seal. The o-ring should form a uniform, solid line around the back of the housing. There will be a small, even gap around the housing between the housing back and the housing front.

Lens Port Options

5516.15 Dome Port (included with housing)

NOTE: This housing is compatible with DLM Port Systems ONLY.

Housing is NOT compatible with FL and DL Lens Port Systems.

11

The housing comes standard with an optical grade acrylic dome port with standard zoom gear. This port provides sharp images and zoom capabilities with the Canon EF-S 18-55mm STM kit lens, the popular

Tokina 10-17mm lens and the Canon 10-18mm STM lens. Minimal vignetting (dark shadows in the corners of the image) will be present in the 10-12mm range when used with the Tokina lens.

An optional zoom gear (Product Number 5509.20), sold separately, is required to operate the lens zoom ring on the Canon 10-18mm STM lens. This lens is accommodated by the standard dome port with no vignetting.

The dome port may be removed without tools to attach the optional

DLM Extended Flat Port for use with the Canon EF-S 60mm Macro lens.

Simply loosen the securing thumb screws and slide the port off.

5516.50 Flat Port (optional)

The optional Flat Port allows use of the 60mm Macro lens in auto-focus mode and features 67mm front threads for the optional attachment of macro converter wet lenses.

The Flat Port can also be combined with the DLM 2.2 Inch Port

Extension for use with the Canon 100mm USM IS Macro lens. The

Port Extension allows for auto focus use only.

No other lenses or ports are compatible with this compact housing. It is not necessary to remove the Dome Port unless you are installing the optional Flat Port or replacing the Dome Port.

Attaching / Removing the Lens Port

To Remove the Lens Port, loosen the three thumb screws so that approximately 4 threads are visible on each thumb screw. This will allow the port to slide over the Port Base. Gently pull up on the port as shown, page 13.

12

1. To attach the Lens Port, lightly lubricate the Port Base O-ring.

When properly lubricated, the O-ring should have an even, slightly shiny appearance. Wipe off any excess lubricant. Lubricant prevents the o-ring from rolling or extruding; it is not a sealing mechanism. Use ONLY Ikelite lubricant.

O-ring

Thumb Screw

Zoom Gear

Port Base

13

2. If using a Zoom Gear, place it over the lens with the teeth side facing away from the housing.

3. Rotate all three Thumb Screws counterclockwise so that approximately 4 threads are visible. This will allow the port to slide over the Port Base.

4. Slide the lens port onto the Port Base and press evenly down toward the housing until it stops. There should be a very thin, even gap between the bottom of the port and the housing front.

5. Rotate all three Thumb Screws clockwise until they are snug against the port. DO NOT overtighten.

OPTIONAL Tray & Handle(s)

Easily add an optional Tray and Single or Dual Handle to allow attachment of strobe arms, strobes and additional accessories. Go to ikelite.com for additional information.

MENU

INFO

Av

13

Optional Tray and Handle

14

Setting Up An External Strobe

We recommend attaching an external strobe for the optimal color and clarity in a wide variety of shooting situations, including daylight photography. An external strobe may be triggered by electrical sync cord.

NOTE: Optional external Tray and Handle necessary to attach an external strobe.

About Sync Cords

Attaching a strobe via electrical sync cord provides fast strobe recycle times. When a compatible Ikelite DS strobe is attached via sync cord, circuitry built into the housing allows the strobe to communicate directly with the camera to trigger the strobe and adjust its power for perfect exposure.

Strobes from SEA&SEA, INON, and Nikonos attached by electrical sync cord are not capable of powering the TTL circuitry built into this housing. These strobes must be used in manual power modes only when connected via electrical sync cord.

Attaching a Sync Cord

A bulkhead cap or sync cord must be attached to the housing for waterproof operation. Never submerge the housing without either a sync cord or waterproof bulkhead cap attached.

1. Remove the bulkhead cap

2. Lightly lubricate the sync cord o-rings. We recommend using only

Ikelite silicone lubricant to eliminate the possibility of swelling due to incompatible compounds.

Line up the pins and receptacles and insert the sync cord plug into the housing bulkhead.

3. Rotate the knurled retaining ring until snug on the housing bulkhead. Do not use pliers or tools to tighten the retaining ring.

15

4. Attach the other end of the sync cord to the bulkhead on your strobe.

O-ring

5. If using an Ikelite strobe, set the strobe to TTL. If using a non-

Ikelite strobe, set the strobe to manual flash and select a manual power setting.

6. Turn on the strobe(s).

7. Turn on the camera.

8. Take a test photo to ensure that your strobe(s) are functioning properly.

Conversion Circuitry

This small compact digital SLR housing has Ikelite designed and patented Conversion Circuitry built right in. The Conversion Circuitry provides real Canon eTTL flash exposure when used with Ikelite DS series strobes. Once a DS series strobe is attached to the camera housing, the conversion circuitry is automatically powered after the strobe is turned on. Once attached, turn the strobe on first before turning on the camera. The circuitry cannot be powered up or used by non-Ikelite strobes.

16

If Manual flash is desired, press the button once, the strobe will fire, press the button a second time within two seconds, and then use manual power settings on the strobe. To go back to TTL, turn the strobe off and back on; return strobe power switch to TTL.

Final Check

1. Re-check the o-ring seal. The seal should form an even, solid line around the back of the housing.

2. Turn on the camera and check all control functions.

3. Make sure that the camera can obtain focus and take a photo.

4. Check battery life and open storage space on your memory card.

5. Check the flash, if using.

6. Submerge the housing in a fresh water tank dedicated to underwater photography equipment. Visually confirm that there are no signs of water intrusion or a steady stream of bubbles coming from one of the housing seals.

Entering the Water

1. If possible, we recommend entering the water without your housing to ensure that you are comfortable and your life-saving equipment is in working order. Once you are stable, have someone pass your camera housing to you.

2. Submerge the housing at the surface of the water and visually confirm that there are no signs of water intrusion or a steady stream of bubbles coming from one of the housing seals. If water does appear to be entering the housing, point the lens port downward and return the housing to the surface as quickly as possible. Please observe all necessary safety precautions. NEVER ascend faster than accepted safety limits.

17

3. Use your hand to gently flush away any small bubbles that may be on the face of the lens port. Bubbles will produce soft focus spots in your photo or video.

Spare Parts

0110 Main O-ring

0200.1 Port Cover

9249.6 Port Thumbscrews Set of 3

9104.5 Waterproof bulkhead cap

5509.19 Zoom Gear for Canon 18-55mm STM

5509.20 Zoom Gear for Canon 10-18mm STM

0184.2 Silicone lubricant resealable 2cc tube

Maintenance

Post-Dive

1. Rinse the housing in fresh water. Rotate the housing controls and press each button while submerged in fresh water to flush out any salt or debris to ensure smooth operation on future dives.

2. NEVER leave your housing in the fresh water rinse tank. Collisions with another person’s equipment can cause scratches and possible damage to your equipment.

3. Stow the housing in a shaded place where it is protected from impact or overheating. If no shade is available, we recommend covering the housing with a towel or cloth.

4. Check the camera’s memory card capacity before your next dive.

Check the battery life of your camera and strobe(s); recharge as necessary.

18

5. Always re-check o-ring seal after opening the housing.

Travel and Storage

1. Remove the camera from the housing for travel or storage.

2. Check the main housing o-ring.

3. Remove Tray and Handle (if attached) along with corresponding hardware and rinse with running water.

4. Close the empty housing and submerge in lukewarm fresh water.

While submerged, rotate each control and depress each button to flush out any salt or debris.

5. Remove the housing from water and rinse with running water.

6. Do not rinse the inside of the housing or submerge the open housing in water. If the inside of the housing needs to be cleaned, wipe with a clean, slightly damp cloth.

7. Dry the housing with a clean, lint-free cloth.

8. Store in a cool, dry place.

9. Like regulators and other pressure-sensitive equipment, we recommend careful care and cleaning along with annual replacement of the factory seals.

Troubleshooting

Water enters the housing

Reclean and reinstall the main o-ring.

Take the housing underwater without a camera installed to ensure that the leaking has been corrected.

19

Photos are over-exposed (too light)

Adjust aperture (smaller), shutter speed (faster), or ISO (lower) setting.

Move lights(s) farther away from your subject.

Adjust exposure compensation in the camera.

Adjust lighting power.

Photos are under-exposed (too dark)

Adjust aperture (larger), shutter speed (slower), or ISO (higher) setting.

Move light(s) closer to your subject.

Adjust exposure compensation in the camera.

Adjust lighting power.

Strobe will not fire

Turn on strobe.

Make sure that the camera’s flash is set to fire on every photo.

Check that the fiber optic cord is properly attached.

Buttons are stuck

Soak the housing in lukewarm fresh water. Depress each button several times while the housing is submerged.

Apply lubricant to the button. Press the button several times to distribute the lubricant.

Button(s) or control(s) do not line up

Ensure that nothing is preventing the camera from going into the housing.

20

Push the camera mounting plate forward until it is flush with the housing base plate.

Camera is not functioning normally underwater

Ensure that the camera mounting plate is pushed all of the way into the housing mounting plate.

Check each housing control while underwater to ensure that they are disengaged. An inadvertently engaged control may limit functioning of the camera.

Check that the zoom control is returned to the center position and is not engaged.

Backscatter or “snow” in images

Position strobes or lights farther away from your lens and at a slight angle. Do not light water between the camera and subject.

Avoid using strobes in extremely low-visibility conditions.

21

Limited Warranty

This Ikelite product is warranted against any manufacturing defects for a period of one (1) year from the original date of purchase. Defective products should be returned to Ikelite postage paid. Ikelite will, at its sole discretion, repair or replace such products, and will return to customer postage paid. All other claims of any nature are not covered.

Except as mentioned above, no other warranty expressed or implied applies to this Ikelite product.

22

Service and Repairs

Ikelite is most interested in performing any service to ensure that all products perform as intended. Evidence of purchase date must be provided to obtain warranty service. No prior authorization is required.

You may return directly to us or through your dealer. Please include a brief description of the problem, any relevant email correspondence, and/or description of the service request. Always include name, shipping address, email address, and phone number inside of the package.

Send postage paid to:

Ikelite Underwater Systems

Attn: Service Department

50 West 33rd Street

Indianapolis, IN 46208 USA

For the separate international customs documentation form that you complete to accompany the shipment, please state or designate that the enclosed products were originally manufactured in the USA and are being returned to the manufacturer for repair service. Value of the equipment listed for customs purposes should be zero.

23

Contact Us

If you have any questions about your product or need advice on getting the images you want, please get in touch with us and we’ll do everything we can to help you capture your unique perspective.

Ikelite Underwater Systems

50 W 33rd St

Indianapolis, IN 46208 USA

(317) 923-4523 [email protected]

24

© 2017 Ikelite Underwater Sytems

6970.03-canon-SL1-2-0317

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement