XTREME POWER CONVERSION T90 An online tower UPS
XTREME POWER CONVERSION T90
For more information, visit www.xpcc.com/t90
Online Tower UPS // 120VAC or 208/230VAC
An online tower UPS that provides
protection against outages and
downtime for critical electronic
equipment
The T90 provides clean reliable power with load segment
control capabilities. The T90 is the perfect choice for
critical business PCs, workstations, servers, IT equipment,
communications systems, or networking equipment.
For high capacity models, reference the
T90 6kVA & 10kVA at www.xpcc.com/t6-10
Protect your business.
PRODUCT SNAPSHOT
›
›
›
›
›
›
›
Available 120V models: 700VA, 1000VA, 1500VA, 2000VA, 3000VA
Available 208/230V model: 1500VA
Available hardwire 120V model: 1500VA
Extended battery packs available
Controlled load segments
UL, cUL, FCC, CE
3 years electronics, 3 years battery warranty (USA and Canada)
FEATURES
High efficiency mode—allows
for increased efficiency and
lower operating costs
Load segment control—loads
can be cycled on/off for longer
holdover time on critical loads
Battery replacement
warning—the UPS tells you
when the batteries need to be
replaced
Multiple communications
capability—RS-232, USB, and
optional Web/SNMP, Relay/dry
contact cards
Generator compatibility—wide
input voltage and frequency
windows allow reliable generator compatibility
Emergency power off—allows
for compliance with the highest
of application safety standards
Extended battery packs—T90
can be connected with external
battery packs for extended runtime applications
$50,000 load protection
policy—protection against
damaged connected equipment
MODEL SELECTION GUIDE
MODEL NUMBER
INPUT
OUTPUT
BATTERY
PHYSICAL
OPTIONAL
BATTERY PACKS
ENVIRONMENT
Capacity
Voltage range
Frequency
Voltage
T90-700
700VA (490W)
Waveform
Frequency
Load segments
Load power factor
Efficiency
Overload capacity
Battery type
Recharge
UPS dimensions
(W x D x H)
UPS weight
Line cord
Receptacles
LCD display
Model number
Dimensions
(W x D x H)
Weight
Battery type
Temperature
Audible noise
Altitude
APPROVALS
WARRANTY
COMMUNICATIONS INTERFACE
INCLUDED IN BOX
AVAILABLE OPTIONS
For more information, visit www.xpcc.com/t90
(2) 12V 7.2AH
31 lbs
T90-1000
T90-1500*
T90-2000
T90-3000
T90i-1500
1000VA (700W) 1500VA (1050W) 2000VA (1400W) 3000VA (2100W) 1500VA (1050W)
60–144VAC**
120–276VAC**
50/60Hz auto sensing
120VAC nominal (100/110/115/127VAC selectable)***
208/220/
230/240VAC
Sine wave, zero transfer time
50/60Hz auto sensing ≤ 1%
Two controlled via software
0.7
High efficiency > 95%, normal mode > 90%
125% for 1 min, 150% for 10 sec
(3) 12V 7.2AH
(3) 12V 9AH
(6) 12V 7.2AH
(6) 12V 9AH
(3) 12V 9AH
4 hours to 90% capacity
6.0 x 16.5 x 9.5 in
8.9 x 16.5 x 14.2 in
6.0 x 16.5 x 9.5 in
38 lbs
5–15P*
(6) 5–15R*
78 lbs
39 lbs
L5–30P
IEC C14 inlet
(4) IEC C13
(10) 5–15R
+ (1) L5–30R
Input/output voltage, input/output frequency, online mode, backup mode, battery capacity, load level
N/A
T90-BP/T90-BP1
T90-BP2
T90-BP/T90-BP1
N/A
N/A
N/A
39 lbs
73 lbs
5–20P
(12) 5–15/20R
T90-BP – 6.0 x 16.5 x 9.5 in; T90-BP1/ T90-BP2 – 8.9 x 16.7 x 14.2 in
T90-BP – 46 lbs; T90-BP1/ T90-BP2 – 88 lbs
T90-BP – 2 x (3) 12V 7.2AH; T90-BP1 – 4 x (3) 12V 7.2AH; T90-BP2 – 2 x (6) 12V 7.2AH
32–104°F (0–40°C)
< 40 dBA
11,500 ft above sea level
UL, cUL, FCC, CE
3 years electronics, 3 years battery warranty (USA and Canada)
RS-232, USB, EPO, intelligent slot for optional cards (Web/SNMP, Relay/dry contact)
User manual, monitoring software, CD, USB cable
Extended warranty, bypass distribution (XBDM), power distribution (XPDU)
*T90-15HW 1500VA model available with input and output terminal blocks; **Depending on load level; ***T90 capacity derates 10% at 110VAC and 20% at 100VAC output voltage
BATTERY RUNTIMES
Load
T90-700
T90-1000
T90-1000
T90(i)-1500
T90(i)-1500
T90-2000
T90-3000
UPS
Half/full
19/7
20/7
20/7
14/6
14/6
20/7
14/6
UPS + 1 BP
UPS + 2 BP
Half/full
Half/full
N/A
N/A
(T90-BP) 99/36
(T90-BP) 214/78
(T90-BP1) 214/78 (T90-BP1) 505/183
(T90-BP) 55/20
(T90-BP) 118/43
(T90-BP1) 118/43 (T90-BP1) 279/102
102/37
214/78
56/20
118/43
For extended runtimes and detailed requirements, see www.xpcc.com/selector;
Runtimes are shown in minutes and will vary based on battery age and site conditions
EPO
RS-232
Intelligent slot for
optional Web/
SNMP or Relay/
dry contact cards
Connection for
optional battery
pack
Breaker
Protect your business.
XPC USA / Denver, CO / sales@xpcc.com
XPC EMEA / Rotterdam, NL / emea@xpcc.com
www.xpcc.com
©2015 Xtreme Power Conversion Corporation. All Rights Reserved. T90.01U (Rev 5/26/15)
T90-3000 rear view
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising