Comnet Copper Line CLFE4EOC Installation and Operation Manual

Add to My manuals
12 Pages

advertisement

Comnet Copper Line CLFE4EOC Installation and Operation Manual | Manualzz

INSTALLATION AND OPERATION MANUAL

CLFE(X)EO(C,U) Series

ETHERNET OVER COPPER EXTENDER

WITH PASS-THROUGH POE TO 15 WATTS

This manual serves the following

ComNet Model Numbers:

CLFE1EOC

CLFE4EOC

CLFE8EOC

CLFE16EOC

CLFE1EOU

CLFE4EOU

CLFE8EOU

CLFE16EOU

The ComNet

CopperLine® Ethernet over copper line supports up to sixteen channels of 10/100Mbps Ethernet with Pass-through PoE over twisted pair cable

(CAT-5, UTP), or over coaxial cable. The single channel units may be powered by a

PoE switch or the included power supply. Four, eight, and sixteen channel units operate from local power. These units provide the ultimate flexibility for extending a powered device (PD) over long distance copper. DIP switches are provided for userselection of local or remote, 10 or 100Mbps, and 1 pair or 4 pair (UTP) settings.

Bi-color (Red/Green) LED indicators are provided for rapidly ascertaining equipment operating status.

Table 2

on

Page 9

describes the LED indicators for each light on the unit.

The CLFE8EO(C,U) and CLFE16EO(C,U) are 1RU rack mountable units. The

CLFE4EO(C,U) units are interchangeable between stand-alone or card mount configurations, or may be DIN-rail mounted by the addition of ComNet model

DINBKT1 or DINBKT4 adaptor plate. The CLFE1EO(C,U) units are stand-alone, or may be DIN-rail mounted by the addition of ComNet model DINBKT4 adaptor. See

Figures A through C on Page 11 for mounting instructions.

TECH SUPPORT: 1.888.678.9427

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 1

INSTALLATION AND OPERATION MANUAL

FIGURE 1 – CLFE1EOC SINGLE CHANNEL COAX UNIT

CLFE(X)EO(C,U) SERIES

ETHERNET

FIGURE 2 – CLFE1EOC SINGLE CHANNEL COAX UNIT

Local/Remote push button

See Installation Instructions,

Step 3

FIGURE 3 – CLFE1EOU SINGLE CHANNEL UTP UNIT

EXT DISTANCE

Black w/ White

Stripe (AC or DC–)

Black (AC or DC+)

Power: Operates on PoE power

OR 9 to 36 VDC

OR 24 VAC

Power Consumption: 1.5 W

Switch UP

Local/Remote

Remote

10/100

10 Mbps

DOWN

Local

100 Mbps

See Installation Instructions for more information

10/100 data rate DIP switch

Local/Remote DIP switch

ETHERNET

FIGURE 4 – CLFE1EOU SINGLE CHANNEL UTP UNIT

EXT DISTANCE

Black w/ White

Stripe (AC or DC–)

Black (AC or DC+)

Power: Operates on PoE power

OR 9 to 36 VDC

OR 24 VAC

Power Consumption: 1.5 W

Switch UP

Local/Remote

Remote

10/100

Wire Pair

10 Mbps

4 Pair

DOWN

Local

100 Mbps

1 Pair

See Installation Instructions for more information

Local/Remote DIP switch

10/100 data rate DIP switch

Wire pair DIP switch

TECH SUPPORT: 1.888.678.9427

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 2

INSTALLATION AND OPERATION MANUAL

FIGURE 3 – CLFE4EOC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT

CLFE(X)EO(C,U) SERIES

CH1 ETHERNET

CH2 ETHERNET

CH3 ETHERNET

CH4 ETHERNET

CH1 EXT

DISTANCE

CH2 EXT

DISTANCE

CH3 EXT

DISTANCE

CH4 EXT

DISTANCE

Black w/ White

Stripe (DC–)

Black (DC+)

Operating Power: 9 to 15 VDC

Power Consumption: 5W

FIGURE 4 – CLFE4EOC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT

Local/Remote DIP switch

See Installation Instructions,

Step 3

TECH SUPPORT: 1.888.678.9427

Local/Remote push button

See Installation Instructions,

Step 3

10/100 data rate

DIP switch

See Installation

Instructions, Step 1

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 3

INSTALLATION AND OPERATION MANUAL

FIGURE 5 – CLFE4EOU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNITS

CLFE(X)EO(C,U) SERIES

CH1 ETHERNET

CH2 ETHERNET

CH3 ETHERNET

CH4 ETHERNET

CH1 EXT

DISTANCE

CH2 EXT

DISTANCE

CH3 EXT

DISTANCE

CH4 EXT

DISTANCE

Black w/ White

Stripe (DC–)

Black (DC+)

Operating Power: 9 to 15 VDC

Power Consumption: 5W

FIGURE 6 – CLFE4EOU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNITS

Data rate DIP switch

See Installation Instructions, Step 1

TECH SUPPORT: 1.888.678.9427

Local/Remote DIP switch

See Installation Instructions, Step 3

Wire pair DIP switch

See Installation Instructions, Step 2

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 4

INSTALLATION AND OPERATION MANUAL

FIGURE 7 – CLFE8EOC MULTICHANNEL RACK COAX UNITS

CLFE(X)EO(C,U) SERIES

Data rate DIP switch

See Installation

Instructions, Step 1

FIGURE 8 – CLFE8EOU MULTICHANNEL RACK UTP UNITS

Data rate DIP switch

See Installation

Instructions, Step 1

Black w/ White Stripe (DC–)

Black (DC+)

Operating Power: 9 to 15 VDC

Power Consumption: 10W

Black w/ White Stripe (DC–)

Black (DC+)

Operating Power: 9 to 15 VDC

Power Consumption: 10W

TECH SUPPORT: 1.888.678.9427

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 5

INSTALLATION AND OPERATION MANUAL

FIGURE 9 – CLFE16EOC MULTICHANNEL RACK COAX UNITS

CLFE(X)EO(C,U) SERIES

Black w/ White Stripe (DC–)

Black (DC+)

Operating Power: 9 to 15 VDC

Power Consumption: 20W

Data rate DIP switch

See Installation

Instructions, Step 1

Data rate DIP switch

See Installation

Instructions, Step 1

Data rate DIP switch

See Installation

Instructions, Step 1

Data rate DIP switch

See Installation

Instructions, Step 1

TECH SUPPORT: 1.888.678.9427

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 6

INSTALLATION AND OPERATION MANUAL

FIGURE 10 – CLFE16EOU MULTICHANNEL RACK UTP UNITS

CLFE(X)EO(C,U) SERIES

Black w/ White Stripe (DC–)

Black (DC+)

Operating Power: 9 to 15 VDC

Power Consumption: 20W

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

TECH SUPPORT: 1.888.678.9427

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 7

INSTALLATION AND OPERATION MANUAL

APPLICATION DIAGRAMS

Note: Coaxial applications use CLFE(X)EO

C

modules; UTP applications use CLFE(X)EO

U

modules.

PoE Pass-Through Mode

PoE

Ethernet Switch or Midspan

Local

CLFE1EO(C,U)

Non-PoE Mode

Ethernet

Switch

Local

CLFE1EO(C,U)

Power

Multichannel PoE Application

Power

Local

CLFE4EO(C,U)

PoE

Ethernet Switch or Midspan

CLFE8EO(C,U)

Power

Multichannel Non-PoE Application

Local

Ethernet

Switch

IMPORTANT NOTE. PLEASE READ.

The applications are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated.

Please contact ComNet’s Design Center to discuss your specific requirements.

TECH SUPPORT: 1.888.678.9427

Power

CLFE16EO(C,U)

CLFE(X)EO(C,U) SERIES

Remote

CLFE1EO(C,U)

Ethernet Connection

Extended Connection

PoE Power

PoE Camera

Remote

CLFE1EO(C,U)

Power

Remote

CLFE1EO(C,U)

CLFE1EO(C,U)

CLFE4EO(C,U)

Power

CLFE1EO(C,U)

CLFE1EO(C,U)

CLFE1EO(C,U)

Remote

CLFE1EO(C,U)

Power

CLFE1EO(C,U)

Power

CLFE4EO(C,U)

Power

CLFE1EO(C,U)

Power

CLFE1EO(C,U)

Power

IP Camera

Power

IP Camera

Power

IP Camera

Power

IP Camera

Power

IP Camera

Power

IP Camera

Power

IP Camera

Power

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 8

PoE Camera

PoE Camera

PoE Camera

PoE Camera

PoE Camera

PoE Camera

PoE Camera

INSTALLATION AND OPERATION MANUAL CLFE(X)EO(C,U) SERIES

INSTALLATION INSTRUCTIONS

1 - SET 10/100 SWITCH

Locate the 10/100 data rate DIP switch on the unit.

Set the data rate according to bandwidth required.

NOTE: The data rate must be set the same on both the local and remote units.

2 - SET WIRE PAIR DIP SWITCHES (UTP MODELS ONLY, FOR COAX MODELS SKIP TO STEP 3)

Locate the wire pair DIP switch on the unit.

Set the pair according to number of twisted wire pairs used (1 or 4).

NOTE: The number of pairs selected must be set the same on both the local and remote units. PoE Pass-Through mode is only available in 4-pair mode and requires a PD device connected to the ComNet remote unit to operate.

3 - SET LOCAL/REMOTE SWITCHES (1 AND 4 CHANNEL UNITS ONLY, FOR RACK UNITS SKIP TO STEP 4)

Locate the Local/Remote Dip switch and set to “LC” at the head end or “RM” at the camera end.

Locate the Local/Remote push button switch (coax units only), and set to the same setting as the dip switch.

The CLFE8EO(C,U) and CLFE16EO(C,U) units are preconfigured as Local devices.

4 - CONNECT EXTENDED WIRING

Connect Extended Distance Port to field wiring.

5 - CONNECT NETWORK WIRING

Using CAT5/5e, connect Local unit to network and Remote unit to camera.

6 - CONNECT POWER

Connect power to unit per the following table:

Unit

CLFE1EO(C,U)

Power Connections per Use Case

Local Power

9 to 36 VDC or 18 to 32 VAC

Pass-Through PoE

No external power required

CLFE4EO(C,U)

9 to 15 VDC (9 VDC

when in a C1 or C2 rack)

CLFE8EO(C,U)

CLFE16EO(C,U)

9 to 15 VDC

Contact ComNet pre-sales support, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.

7 - VERIFY FUNCTIONALITY

See LED table below and Troubleshooting Guide if corrective action is needed. See figures beginning on page 6 for LED configurations for each model.

GREEN

YELLOW

OFF

PWR

Power Applied

Power Off

Indicating LEDs

Ethernet Link

Link Established

No Link

Ethernet Activity

Activity Detected

No Activity

EXT LNK

10Mbps

100Mbps

No Link

Ethernet

Activity

Ethernet

Link

EXT Link

CLFE1EOU Only

Power

TECH SUPPORT: 1.888.678.9427

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 9

INSTALLATION AND OPERATION MANUAL CLFE(X)EO(C,U) SERIES

APPLICATION NOTES

1 Mixed PoE and Non-PoE systems can be implemented.

2 All Non-PoE systems require local power.

3 PoE powered operation requires that a PoE Camera be connected, and that the camera power requirements are understood.

4 Multiple Channel units (CLFE4EO(C,U), CLFE8EO(C,U), CLFE16EO(C,U) require 9 to 15 VDC for proper operation. The

CLFE4EO(C,U) can be used in a C1, C2, or C3.

5 Single Channel units (CLFE1EO(C,U)) require power for all Non-PoE applications. Local power can be used in PoE application to minimize PoE consumption.

6 Lower data rates generally provide longer operating distances.

7 Rack units (CLFE8EO(C,U), CLFE16EO(C,U)) are pre-configured for Local (LC) and have no configurable Local/Remote switch. Any unit connected to one of these rack units via an extended distance port must be configured as Remote (RM) for proper operation.

APPROXIMATE MAXIMUM EXTENDED DISTANCES

1

Media

Data Rate

Source Power

COAX - RG59/U

10M 100M

Non-PoE Max.Distance

PoE CLASS2 (6.5W)

PoE CLASS3 (13W)

1

1

1

15W 30W

3,000 ft

914 m

5,000 ft

1,524 m

3,000 ft

914 m

750 ft

228 m

850 ft

259 m

15W 30W

2,000 ft

610 m

2,000 ft

610 m

2,000 ft

610 m

750 ft

228 m

850 ft

259 m

UTP - 4 pair

10M

15W 30W

3,000 ft

914 m

3,000 ft

914 m

3,000 ft

914 m

750 ft

228 m

850 ft

259 m

15W

2,000 ft

610 m

2,000 ft

610 m

2,000 ft

610 m

750 ft

228 m

100M

30W

850 ft

259 m

UTP - 1 pair

10M

3,000 ft

914 m

N/A

N/A

N/A

100M

1,000 ft

305 m

[1] Distance figures are based on a 50 V PSE PoE power source, and external power supplies for the extenders. Distance figures are obtained using in-house testing mirroring installations. Factors such as coaxial and copper cable quality, the number of connectors and splices in the cable run, the use of PoE, and environmental conditions encountered within the installation might affect the actual transmission distance and should be taken into consideration. Due to advanced negotiation signaling required in IEEE802.3at applications, pass-through applications are limited to

IEEE802.3af PD devices only. When using UTP models Pass-Through PoE is only possible in 4-pair mode.

TROUBLESHOOTING GUIDE

Problem

Indicating LEDs not lighting

No Communication

Bad Video

PoE Not Supplied to PD

Steps to Take

Non-PoE: Check that power is properly applied to the unit

PoE: Check that PoE camera is connected, PoE source is enabled.

Check Ethernet Link LEDs, Extended Link LEDs, All Connections, Local/Remote and 10/100 switches are set properly.

Verify that Local units are installed at the head end and that Remote units are installed in the field.

Make sure Data Rate Switch is set properly, and the extended distance is within specifications (see Table “Approximate

Maximum Extended Distances”).

Make sure camera is IEEE 802.3af rated, PoE Source switch is set properly, and the extended distance is within specifications (see Table

“Approximate Maximum Extended Distances”).

Units not reaching estimated max distances over COAX or CAT5/UTP

Check extended distance cable and connections. Try connection on a short cable to eliminate possibility of faulty cabling.

Check that the extended distance wire is connected to Extended Distance Port.

Verify that there is no additional equipment (e.g. surge protector) on the Extended Link. The cable should be continuous from end to end, with no active components.

TECH SUPPORT: 1.888.678.9427

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 10

INSTALLATION AND OPERATION MANUAL

PRODUCT DIMENSIONS

The CLFE1EO(C,U) is supplied as a standalone/surface mount (small size) module.

The CLFE4EO(C,U) is supplied as a standalone/surface/rack (ComFit) module.

The CLFE8EO(C,U) and CLFE16EO(C,U) are supplied as 19 wide rack units for standalone or rack installation.

FIGURE A

Dimensions are for a small size module

0.8cm

[0.31in]

0.4cm

[0.16in]

4.19cm

[1.65in]

0.62cm

[0.24in]

FIGURE B

Dimensions are for a ComFit module

13.2cm

[5.2in]

11.9cm

[4.7in]

6.37cm

[2.50in]

CLFE(X)EO(C,U) SERIES

8.38cm

[3.3in]

2.7cm

[1.06in]

FIGURE C

Dimensions are for a 19″ Rack Unit

1.9cm

[0.75in]

44.45cm

[17.50in]

0.63cm

[0.25in]

2.75cm

[1.1in]

7.5cm

[2.9in]

15cm

[5.9in]

1.9cm

[0.75in]

4.37cm

[1.72in]

TECH SUPPORT: 1.888.678.9427

48.26cm

[19.0in]

15.44cm

[6.08in]

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 11

INSTALLATION AND OPERATION MANUAL CLFE(X)EO(C,U) SERIES

INSTALLATION CONSIDERATIONS

These units are supplied as Standalone/Rack mounted module. Units should be installed in dry locations protected from extremes of temperature and humidity.

WARNING : Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS:

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (T specified by the manufacturer.

ma

)

B) Reduced Air Flow

- Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

3 CORPORATE DRIVE

|

DANBURY, CONNECTICUT 06810

|

USA

|

T: 203.796.5300

|

F: 203.796.5303

|

TECH SUPPORT: 1.888.678.9427

|

[email protected]

8 TURNBERRY PARK ROAD

|

GILDERSOME

|

MORLEY

|

LEEDS, UK LS27 7LE

|

T: +44 (0)113 307 6400

|

F: +44 (0)113 253 7462

|

[email protected]

© 2015 Communication Networks. All Rights Reserved. “ComNet,” the “ComNet Logo,” “CopperLine,” and the “CopperLine Logo” are registered trademarks of Communication Networks.

INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 12