Euphonix Media Application Controller Single Workstation

Add to my manuals
40 Pages

advertisement

Euphonix Media Application Controller Single Workstation | Manualzz

Euphonix Media Application Controller

Single Workstation Installation Guide

Document Revision

: C

Software Version

: 1.1.3 & higher

Part Number

: 840-10049-02

Release Date

: November 2006

Euphonix, Inc.

220 Portage Ave.

Palo Alto, California 94306

Phone: 650-855-0400

Fax: 650-855-0410

Web: http://www.euphonix.com

e-mail: [email protected]

Media Application Controller Single Workstation Install Guide

Table of Contents

Chapter 1: Hardware Connections and MC Client Setup

.............................5

1.1

Connect the MC.........................................................................................5

1.2

Network Configuration..............................................................................6

1.2.1

MC Standalone............................................................................6

1.2.2

System 5-MC ..............................................................................6

1.3

EuCon Software Installation......................................................................7

1.4

Workstation Connection and Control........................................................8

1.5

Ready to Proceed.....................................................................................10

Chapter 2: Logic Pro

.......................................................................................................11

Chapter 3: Nuendo–PC and Mac

..............................................................................13

Chapter 4: Pro Tools

.......................................................................................................15

4.1

Workstation Configuration......................................................................15

4.2

Pro Tools Configuration ..........................................................................16

Chapter 5: Pyramix

..........................................................................................................19

Chapter 6: Support and Troubleshooting

...........................................................23

6.1

Support ....................................................................................................23

6.2

Troubleshooting.......................................................................................23

Appendix A:DAW Parts List and Schematics

....................................................25

iii

Media Application Controller Single Workstation Install Guide

Chapter 1: Hardware Connections and MC Client Setup

Schematics and parts are listed for each DAW setup in Appendix A:

DAW Parts List and Schematics

.

1.1

Connect the MC

1.

Unpack the MC from its packaging and select a place to put it. The MC should go on a hard flat surface in order to allow proper ventilation. (System 5-MC has its own frame for the MC and CM408T modules).

NOTE: The MC and CM408T modules require sufficient ventilation space on the bottom. The MC has detachable feet for standalone users without a System 5 frame, but the CM408T modules do not. If you do not use a System 5 frame, you MUST have at least 1 inch of clearance under the CM408T modules and

MC or damage to the units may occur.

Use Figure 1-1 as a reference to connect the MC to its components.

VGA KEYBOARD USB

FOOT

SWITCH HEADPHONES

DC IN TALKBACK MIC

VGA and

Keyboard

USB Talkback Mic Output LAN Foot

Switch

Headphone DC In

Figure 1-1

MC Rear Panel

2.

Plug the power supply into the

DC In

port on the right side as you look at the rear panel.

Be careful plugging this in as the connector has easily-bent pins. When the pins are seated, twist the ring on the connector’s side until it locks. Do not turn on the MC yet; network configuration must be completed first.

WARNING: Attach power supply to the MC BEFORE plugging into AC power or the unit may be damaged.

5

Media Application Controller Single Workstation Install Guide Hardware Connections and MC Client Setup

1.2

Network Configuration

1.2.1

MC Standalone

Using one of the RJ-45 Ethernet (included) cables, connect your workstation to one of the

LAN

ports on the Netgear RP614 router. Then connect the MC to one of the other

LAN ports on the Netgear router.

NOTE: You have now created a small local area network comprised of just the MC and your workstation. If you wish to have access to an outside network, either a studio facility LAN or the Internet, connect the WAN port on the Netgear to your studio’s network switch, or to your cable/DSL modem.

The MC ships with DHCP enabled, allowing it to automatically obtain an IP address.

The Netgear RP614 has a DHCP server and hands out IP addresses to the devices connected to its LAN ports (the MC and your workstation). This allows for easy plug and play network configuration. For this reason, the Netgear router must be turned on before the MC and your workstation.

1.2.2

System 5-MC

1.

Connect the MC and CM408T modules to

LAN

ports on the SonicWALL 1260 router.

2.

Connect your workstation to a

LAN

port on the SonicWALL.

The MC ships with DHCP enabled, allowing it to automatically obtain an IP address. The SonicWALL ships from Euphonix with its DHCP server enabled, such that it hands out IP addresses to the MC, CM408T modules, and your workstation. For this reason the SonicWALL must be turned on before the MC,

CM408T modules, and your workstation.

6

Media Application Controller Single Workstation Install Guide Hardware Connections and MC Client Setup

1.3

EuCon Software Installation

1.

Insert the

Euphonix MC Software Installation

CD in your workstation’s CD/

DVD drive.

2.

In Mac OS X, double-click the CD icon on the desktop, and double-click the

EuConWS

package.

The Install program launches. Proceed to Step 4.

3.

In Windows, if AutoRun is enabled, the setup program starts from the CD automatically. If AutoRun is

not

enabled: a. Minimize all programs. b. Double-click

My Computer

on the desktop to display the drives on your computer. c. Double-click the CD/DVD drive. d. Double-click the

EuConWS

executable file.

The Setup Wizard begins running.

4.

Click

Next

and choose a directory to install the software.

The default Windows directory is C:\Program Files\Euphonix\EuCon.

The default Macintosh OS X directory is the Applications folder.

5.

For Windows installations, click

Next

to customize the software components to install.

EuCon Workstation Core

is automatically selected (this is the basic software used to communicate with the MC. Select further options according to your DAW: a. For Nuendo workstations, select only the

EuCon adapter for Nuendo

and

VST plugin layouts for Nuendo

options. b. For Pyramix, select only the

EuCon adapter for Pyramix

option.

c. For all other DAWs, select only the

Studio Monitor Express

option.

6.

Click

Next

to continue.

7.

Select locations for application shortcuts in the

Start

menu.

The default is a

EuCon

folder in the

Start

menu with shortcuts to the MC’s applications.

8.

Click

Next

to continue.

The Wizard now displays a summary of all options selected during the setup process. To change them, click

Back

until the desired setup option appears.

7

Media Application Controller Single Workstation Install Guide Hardware Connections and MC Client Setup

9.

Click

Install

.

The Wizard installs the selected components to your workstation.

10.

Click

Finish

to exit the Wizard.

NOTE: When first running the MC Client, the Windows Firewall may ask whether to block or unblock MC Client and EuCon Discovery from accessing the Internet or local area network. Because all communication between the MC Client and the MC occurs through the workstation's network connection, you must select

Unblock or it will not communicate with the MC.

1.4

Workstation Connection and Control

1.

To connect the MC to your workstation, make sure the MC Client is running on your workstation, and then press the Strip Control

Setup

key on the right side of the MC.

Layouts

Setup

Setup

Strip Control

Setup

key

Figure 1-2

Strip Control Setup key

The Touchscreen in Figure 1-3 opens and displays all workstations available

on the network on the right. There are two choices: none/disconnect and your workstation (showing computer name, user name, and operating system).

(Figure 1-3 displays a multiple workstation setup).

8

Media Application Controller Single Workstation Install Guide Hardware Connections and MC Client Setup

Figure 1-3

Workstation Touchscreen

2.

Touch the desired Workstation key on the left of the Touchscreen.

These buttons map to the physical

Workstation Keys

on the upper right of the

MC. For simplicity in single workstation setups, Euphonix suggests using the

1

key.

Workstation

1 2

3

4

Figure 1-4

Workstation keys

3.

Touch your workstation in the list to assign it to the selected number.

4.

Press the Strip Control

Setup

key again to exit Workstation assignment mode.

5.

Press the

Workstation

key to which you assigned your workstation to control your workstation. The MC’s right-hand trackball (which acts as the mouse) and keyboard should now function just as if they were connected directly to your workstation.

9

Media Application Controller Single Workstation Install Guide Hardware Connections and MC Client Setup

1.5

Ready to Proceed

You have successfully connected your MC to your workstation. Proceed to the chapter of this installation guide for your DAW software to configure it to work with the MC.

Chapter 2:

Logic Pro

Chapter 3:

Nuendo–PC and Mac

Chapter 4:

Pro Tools

Chapter 5:

Pyramix

NOTE: If your MC did not connect properly, or a step failed, see Chapter 6: Support and Troubleshooting.

10

Media Application Controller Single Workstation Install Guide

Chapter 2: Logic Pro

Logic Pro (version 7.2.1 and higher) has EuCon support and connectivity built into the application. With the MC Client running on your Macintosh, load Logic Pro, and the

MC automatically connects to the application and displays the Logic Pro application set.

Versions of Logic prior to 7.2.1 do not have EuCon support. However, the updates for

Logic are part of Apple’s Software Update program, so simply check for new updates

(

Apple Menu-> System Preferences -> Software Update -> Check Now

), download, and install the Logic 7.2.1 update. Then re-open Logic and the MC will connect. You have now successfully set up the MC to operate with your Logic Pro workstation.

• See the MC Operation Manual to learn about the MC’s application sets, touchscreens, and any other information.

• Check the Euphonix website ( www.euphonix.com

) for technical bulletins, product support notices, and new software releases.

• Please register your MC by filling out the online registration form at www.euphonix.com/registration . Registration is required to download software updates.

11

Media Application Controller Single Workstation Install Guide Logic Pro

12

Media Application Controller Single Workstation Install Guide

Chapter 3: Nuendo–PC and Mac

To enable Nuendo to work with the MC, you must obtain a Nuendo EuCon Adapter license from Euphonix and download it to your Nuendo USB protection device (dongle):

1.

Close all open applications. Make sure your Syncrosoft USB dongle is plugged into your Nuendo workstation.

2.

Start the Syncrosoft License Control Center by choosing

Start Menu->Steinberg Nuendo 3->License Control Center

.

Windows

: Click

Start Menu->Syncrosoft->License Control Center

.

OS X

: Navigate to the

Applications\Syncrosoft

folder and run

License

Control Center

.

3.

Choose

License Download

from the

Wizards

menu.

Choose

License Transfer

to transfer an existing Nuendo EuCon license to a new USB dongle.

4.

When prompted, enter the activation code for Nuendo EuCon provided by

Euphonix.

5.

Make sure you are downloading the correct license, then click

Next

.

6.

If you have more than one Syncrosoft USB dongle attached to your workstation, select the one onto which you wish to download the license. Click

Next

.

7.

Press

Download

to transfer the license onto your USB dongle.

8.

Close the wizard and open Nuendo.

The Nuendo EuCon Adapter must be installed during the EuConWS software installation

(see page 7). Note that this is the MC Client’s Nuendo adapter. For Nuendo to commu-

nicate with the MC, Nuendo’s EuCon device must be added in the Nuendo Device Setup dialog:

1.

Choose

Device Setup

from Nuendo’s

Devices

menu.

The Device Setup dialog opens.

2.

Click the + button (add) on the top-left.

A drop-down list of devices appears.

EuCon

should appear near the top of the list. If not, check that you have successfully downloaded the license for the Eu-

Con Adapter to your USB dongle using the License Control Center.

13

Media Application Controller Single Workstation Install Guide Nuendo–PC and Mac

3.

Select

EuCon

from the drop-down list.

The EuCon device is added and the MC surface immediately updates with the

Nuendo default Application Set to reflect the open Nuendo project. For the

System 5-MC, the MC auto-assigns the Nuendo channels to the CM408T strips, beginning with channel 1 on the first CM408T’s leftmost strip.

Steinberg has created a default Nuendo Application Set with the most commonly used functions and commands.

14

Media Application Controller Single Workstation Install Guide

Chapter 4: Pro Tools

4.1

Workstation Configuration

After installing the EuCon software and restarting your Mac, the MC Client launches automatically upon startup of OS X and EuCon applications can now function.

To configure your HUI or Mackie Control applications to work with the MC:

1.

Click

Apple Menu-> System Preferences

.

The System Preferences dialog opens.

2.

Click on EuPrefsPane.

The Euphonix Preferences pane opens.

Figure 4-1

Euphonix Preferences pane

3.

Open a Finder window and navigate to the folder containing the HUI or Mackie

Control application(s) you wish to use.

4.

Drag the application(s) into the Euphonix Preferences pane.

15

Media Application Controller Single Workstation Install Guide Pro Tools

NOTE: You must drag the actual application icon into the preferences pane, not a shortcut or alias!

5.

For each application, select

HUI

or

Mackie Control

from the drop-down menu under

Protocol

, and select the MIDI ports for the application to use.

NOTE: The EuCon software sets up a virtual MIDI driver with 32 ports, and each application can use up to four (the limit with HUI applications). Keep track of which application uses which ports in order to configure them properly.

6.

Close the Euphonix Preferences pane. When prompted, restart your Macintosh.

7.

Connect the MC to the Macintosh.

4.2

Pro Tools Configuration

To configure Pro Tools to recognize the MC:

1.

Launch Pro Tools.

2.

Choose

Peripherals

from the Operations menu.

The Peripherals dialog opens.

3.

Click the

MIDI Controllers

tab.

Figure 4-2

Pro Tools Peripherals dialog

16

Media Application Controller Single Workstation Install Guide Pro Tools

Pro Tools has configuration boxes for the four possible controllers. MC standalone users need to configure only one controller. System 5-MC users need to configure

one controller for each CM408T module

because the MC mirrors one CM408T and does not require an extra HUI controller.

4.

For each controller you use, select

HUI

from the

Type

drop-down menu.

5.

Configure each controller to have the input and output MIDI ports set for Pro-

Tools in the Euphonix Preferences Pane. Click on the

Receive From

and

Send

To

drop-down menus, hover over

Predefined

, then select from the Euphonix

MIDI ports.

For example, if you set ProTools to use MIDI ports 9–12, your first HUI controller’s receive and transmit ports should be set to

EphMIDIEP9

.

Figure 4-3

Excerpt from Pro Tools MIDI menu

6.

Select

8

from the

Ch #

drop-down menu as the number of channels for each controller.

7.

Press

OK

.

The MC updates the channel and track information.

17

Media Application Controller Single Workstation Install Guide Pro Tools

18

Media Application Controller Single Workstation Install Guide

Chapter 5: Pyramix

To enable the use of the MC with Pyramix, the

EuCon adapter for Pyramix

checkbox

must be selected during the MC Client software installation (see page 7). Then add the

MC as an installed controller in Pyramix:

1.

Launch the Pyramix Virtual Studio software.

2.

Press the

Pref

key on the top bank of the MC Soft Keys.

The bank changes to show two options:

Home

: Restores the first bank of soft keys

Show Settings

: Opens the Pyramix Settings dialog box (alternatively, choose

All Settings

from the

Settings

menu in Pyramix Virtual Studio).

3.

Click

Show Settings

.

A dialog appears showing a list of the various types of adjustable settings on the left side.

19

Media Application Controller Single Workstation Install Guide Pyramix

Figure 5-1

Pyramix Settings

4.

Click

Controller

.

The right pane shows any installed controllers. However, at this point the pane is empty unless other interface controllers have been installed previously.

20

Media Application Controller Single Workstation Install Guide

5.

Click the

Add

button.

The Controller Properties dialog opens.

Pyramix

Figure 5-2

Controller Properties dialog

6.

Type the desired name for the MC in the

Name

field (i.e.,

MC in Studio 2

).

7.

Select the

Enable

checkbox.

8.

Choose

OASIS

from the

Driver

drop-down selection box.

9.

Click the

Properties

button next to the

Driver

selection box.

The OASIS Configuration Properties dialog opens.

Figure 5-3

OASIS Configuration Properties dialog

10.

Select

EuCon

from the

Transport

drop-down menu.

If

EuCon

is not in the drop-down menu, it is probably because the MC Client is not running. Check that the MC Client menu tray icon is present. If not, launch the MC Client using the shortcuts in the

Start

menu or the

Euphonix

folder.

21

Media Application Controller Single Workstation Install Guide Pyramix

Leave the

Station ID

at its default setting of 1 unless you have multiple controllers, in which case simply increment the setting (i.e., if two controllers are installed, set the

Station ID

= 3 for the MC).

11.

Press

OK

to exit that dialog, press

OK

on the Controller Properties dialog and press

OK

on the General Settings dialog.

12.

Close Pyramix, reboot the workstation, and then open Pyramix Virtual Studio.

Pyramix will not connect to the MC properly without rebooting the workstation.

The MC will now load the default Pyramix Application Set if a project is open. Otherwise, the Application Set will

not

be loaded, but the Soft Keys at the top-left illuminate to show that EuCon communication is enabled.

22

Media Application Controller Single Workstation Install Guide

Chapter 6: Support and Troubleshooting

The MC is a professional control surface engineered with industrial-grade components, and it should operate reliably in your studio setup. It is, however, a complex device and issues can arise due to environmental or other factors. Euphonix provides a one year warranty on the MC and CM408T modules.

If you are having trouble with your MC, these sections can either resolve the problem or provide useful troubleshooting information for our technical support personnel.

6.1

Support

Euphonix maintains a support section for the MC on our website: http://www.euphonix.com/support/mc.htm

. This page has the latest versions of:

• the EuCon software (for both workstations and the MC);

• this manual;

• constantly expanding FAQ section.

You must sign up for a user account to download new versions of the EuCon software.

If you cannot find an answer for your question in this manual, consult the FAQ section to see if it is answered there.

Those who purchased their MC through a VAR (

value-added reseller

), such as Guitar

Center Pro, are supported by that reseller. Euphonix does not provide service directly to VAR customers. This avoids confusion between Euphonix and your VAR regarding your MC and its support needs. System 5-MCs are supported only by Euphonix.

6.2

Troubleshooting

If you are having problems with your MC or System-5 MC:

1.

Look for a solution in the

Common Issues and Solutions

section below.

2.

Then try the Euphonix website’s FAQ or technical bulletins.

3.

If you still are unable to solve your issue, contact your VAR (if applicable) or

Euphonix for support.

Our technical support phone hours (650-855-0412) are Monday through Friday

9 AM – 5 PM. The website is always available.

23

Media Application Controller Single Workstation Install Guide Support and Troubleshooting

Common Issues and Solutions

My MC does not turn on.

Make sure the MC’s power connector is securely connected. Push on it lightly to seat it, twist the outer ring to lock it onto the MC, and make sure the transformer is plugged into the wall.

The MC cannot connect to a workstation; the workstation does not appear in the

MC's Workstation Setup screen

.

• Make sure the MC Client is installed on the workstation, and that the Windows

Firewall is not blocking the MC Client and EuCon Discovery applications.

• The MC, CM408T modules, and workstation must be connected to the same network segment (router/switch): the Netgear RP614 or SonicWALL 1260.

• Both the workstation and MC must have the

same

version of the EuCon software.

• To further troubleshoot this issue, we recommend using a cross-over cable between the MC and one workstation, to remove network variables from the equation. Once this setup is working, re-connect the MC and workstation(s) to the switch/router, and verify proper operation.

The MC does not connect to Nuendo.

• The Nuendo EuCon Adapter must also be installed when installing the EuCon software on your workstation. Make sure Studio Monitor Pro is

NOT

installed, as SME usurps Nuendo when installed on the same machine.

• Make sure your Nuendo license includes EuCon connectivity, and that you have added the EuCon device in Nuendo Device Setup.

• Make sure the MC is properly connected to the workstation. The MC’s Main

Touchscreen should display the network name of your workstation in the upper left-hand corner.

The MC does not connect to Pyramix.

• The Pyramix EuCon Adapter must also be installed when installing the EuCon software on your workstation. Make sure Studio Monitor Pro is

NOT

installed, as SME interferes with Pyramix-MC connectivity.

• Verify that the Pyramix connection procedure has been properly executed, and that the MC is properly connected to the workstation.

The talkback mic does not produce any audio.

The talkback mic is a condenser microphone and the XLR output is at mic level so it must be connected to a pre-amp with +48V phantom power.

24

Media Application Controller Single Workstation Install Guide

Appendix A: DAW Parts List and Schematics

The following diagrams illustrate how to use the supplied parts to interconnect the MC with the supported DAWs.

25

Apple Logic Pro / Euphonix Media Controller Installation

Required Parts

QTY

MC Only

1 Euphonix MC Controller

1 Apple 20" Cinema Display

1 Netgear RP614 DHCP Router/Switch

(included with MC packout)

1 USB Memory Stick (for app sets and configuration data)

1 DVI M-M

(included with Cinema Display packout)

2 Ethernet Cable

(included with MC packout)

1 Apple G5 Workstation fitted:

1 Apple Logic Pro 7.21 or higher

1 Apogee Ensemble Audio Interface

QTY

System 5 MC (32 Fader shown)

DESCRIPTION

1 Euphonix 32 Fader System 5 MC

1 Sonic Wall Pro 1260 DHCP Router/Ethernet Switch

1 Apple 20" Cinema Display

1 DVI Cable M-M

(included with Cinema Display packout)

6 Ethernet Cable

1 USB Memory Stick (for app sets and configuration data)

1 Apple G5 Workstation fitted:

1 DVI Cable M-M

1 Apple Logic Pro (V7.2 or higher)

1 Apogee Ensemble Audio Interface

MC_LogicPro_Install_AdditionalItems_V1-3 5/10/2006

F

E

D

C

B

A

H

G

WAN

USB

MEMORY STICK

WAN

NETGEAR

RP614

NET 1

NET 2

NET 3

NET 4

1 2

APPLE G5

LOGIC PRO

NET 1

NET 2

DVI OUT

PCIe

USB

USB

USB

FW400

1

2

3

EUPHONIX

MC CONTROLLER

4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7

1

1

2

3

4

2

3

4

MIC

IN

LINE

IN

WC

IN

1

2

FIRE

WIRE

APOGEE

ENSEMBLE

LINE

OUT

1

2

3

4

5

6

7

8

WC

OUT

8 9 10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

B

A

D

C

F

E

H

G

EUPHONIX SYSTEM

5MC

FADERS 1-8

EUPHONIX SYSTEM

5MC

FADERS 9-16

EUPHONIX

MC CONTROLLER

EUPHONIX SYSTEM

5MC

FADERS 17-24

EUPHONIX SYSTEM

5MC

FADERS 25-32

USB

MEMORY STICK

1 2

APPLE G5

LOGIC PRO

NET 1

NET 2

DVI OUT

PCIe

USB

USB

USB

FW400

1

2

3 4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7

1

1

2

3

4

2

3

4

MIC

IN

LINE

IN

WC

IN

1

2

FIRE

WIRE

APOGEE

ENSEMBLE

LINE

OUT

1

2

3

4

5

6

7

8

WC

OUT

8 9

1

2

10

11

12

7

8

9

3

4

5

6

PORTS

SONIC WALL 1260

ROUTER/SWITCH

PORTS

13

14

22

23

24

19

20

21

15

16

17

18

10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

Nuendo PC / Euphonix Media Controller Installation

Required Parts

MC Only

QTY

1 Euphonix MC Controller

1 Apple 20" Cinema Display

1 Netgear RP614 DHCP Router/Switch

(included with MC packout)

1 DVI M-M

(included with Cinema Display packout)

2 Ethernet Cable

(included with MC packout)

1 USB Memory Stick (for app sets and configuration data)

1 PC Audio Labs (or equivalent) Workstation fitted:

1 Nuendo V3.2

(PC Version)

1 Euphonix Nuendo EUCON License

1 RME Fireface 400

1 Firewire Cable

QTY

System 5 MC

(32 Fader shown)

DESCRIPTION

1 Euphonix 32 Fader System 5 MC

1 Sonic Wall Pro 1260 DHCP Router/Ethernet Switch

1 Apple 20" Cinema Display

1 DVI Cable M-M

(included with Cinema Display packout)

6 Ethernet Cable

1 USB Memory Stick (for app sets and configuration data)

1 PC Audio Labs (or equivalent) Workstation fitted:

1

Nuendo V3.2.1

(PC Version)

1 Euphonix Nuendo EUCO License

1 RME Fireface 400

1 Firewire Cable

MC_NUENDO_PC_Install_AdditionalItems_V1-2 5/10/2006

F

E

D

C

B

A

H

G

WAN

USB

MEMORY STICK

WAN

NETGEAR

RP614

NET 1

NET 2

NET 3

NET 4

1

PC AUDIO LABS

NUENDO 3.2

NET 1

NET 2

DVI OUT

PCI

USB

USB

USB

FW400

1

2

2 3

EUPHONIX

MC CONTROLLER

4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7

3

4

1

1

2

2

3

4

MIC

IN

INST

IN

LINE

IN

ADAT IN

SPDIFIN

RME

FIREFACE 400

LINE

OUT

3

4

5

1

2

6

7

8

ADAT OUT

SPDIF OUT

1

2

FIRE

WIRE

8 9 10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

B

A

D

C

F

E

H

G

USB

MEMORY STICK

1

PC AUDIO LABS

NUENDO 3.2

NET 1

NET 2

DVI OUT

PCI

USB

USB

USB

FW400

1

2

2 3

EUPHONIX SYSTEM

5MC

FADERS 1-8

EUPHONIX SYSTEM

5MC

FADERS 9-16

EUPHONIX

MC CONTROLLER

EUPHONIX SYSTEM

5MC

FADERS 17-24

EUPHONIX SYSTEM

5MC

FADERS 25-32

4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7

3

4

1

1

2

2

3

4

MIC

IN

INST

IN

LINE

IN

ADAT IN

SPDIFIN

RME

FIREFACE 400

LINE

OUT

3

4

5

1

2

6

7

8

ADAT OUT

SPDIF OUT

1

2

FIRE

WIRE

8 9

1

2

10

11

12

7

8

9

3

4

5

6

PORTS

SONIC WALL 1260

ROUTER/SWITCH

PORTS

13

14

22

23

24

19

20

21

15

16

17

18

10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

Nuendo Apple / Euphonix Media Controller Installation

Required Parts

MC Only

QTY

1 Euphonix MC Controller

1 Apple 20" Cinema Display

1 Netgear RP614 DHCP Router/Switch

(included with MC packout)

1 DVI M-M

(included with Cinema Display packout)

2

Ethernet Cable

(included with MC packout)

1 USB Memory Stick (for app sets and configuration data)

1 Apple G5 Workstation fitted:

1

Nuendo V3.2.1

(MAC V ersion)

1 Euphonix Nuendo EUCON License

1 RME Fireface 400

1 Firewire Cable

QTY

System 5 MC

(32 Fader shown)

DESCRIPTION

1 Euphonix 32 Fader System 5 MC

1 Sonic Wall Pro 1260 DHCP Router/Ethernet Switch

1 Apple 20" Cinema Display

1 DVI Cable M-M

(included with Cinema Display packout)

6 Ethernet Cable

1 USB Memory Stick (for app sets and configuration data)

1 Apple G5Workstation fitted:

1

Nuendo V3.2.1

(MAC Version)

1 Euphonix Nuendo EUCO License

1 RME Fireface 400

1 Firewire Cable

MC_NUENDO_MAC_Install_AdditionalItems_V1-2 5/10/2006

F

E

D

C

B

A

H

G

WAN

USB

MEMORY STICK

WAN

NETGEAR

RP614

NET 1

NET 2

NET 3

NET 4

1

Apple G5

NUENDO 3.2.1

NET 1

NET 2

DVI OUT

PCIe

USB

USB

USB

FW400

1

2

2 3

EUPHONIX

MC CONTROLLER

4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7

3

4

1

1

2

2

3

4

MIC

IN

INST

IN

LINE

IN

ADAT IN

SPDIFIN

RME

FIREFACE 400

LINE

OUT

3

4

5

1

2

6

7

8

ADAT OUT

SPDIF OUT

1

2

FIRE

WIRE

8 9 10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

B

A

D

C

F

E

H

G

USB

MEMORY STICK

1

Apple G5

NUENDO 3.2.1

NET 1

NET 2

DVI OUT

PCIe

USB

USB

USB

FW400

1

2

2 3

EUPHONIX SYSTEM

5MC

FADERS 1-8

EUPHONIX SYSTEM

5MC

FADERS 9-16

EUPHONIX

MC CONTROLLER

EUPHONIX SYSTEM

5MC

FADERS 17-24

EUPHONIX SYSTEM

5MC

FADERS 25-32

4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7

3

4

1

1

2

2

3

4

MIC

IN

INST

IN

LINE

IN

ADAT IN

SPDIFIN

RME

FIREFACE 400

LINE

OUT

3

4

5

1

2

6

7

8

ADAT OUT

SPDIF OUT

1

2

FIRE

WIRE

8 9

1

2

10

11

12

7

8

9

3

4

5

6

PORTS

SONIC WALL 1260

ROUTER/SWITCH

PORTS

13

14

22

23

24

19

20

21

15

16

17

18

10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

ProTools LE7 / Euphonix Media Controller Installation

Required Parts

MC Only

QTY

1 Euphonix MC Controller

1 Apple 20" Cinema Display

1 Netgear RP614 DHCP Router/Switch

(included with MC packout)

2 Ethernet Cable

(included with MC packout)

1 USB Memory Stick (for app sets and configuration data)

1 Apple G5 Workstation fitted:

1

DigiDesign ProTools LE7

(or higher)

1 DigiDesign 007 Rack

QTY

System 5 MC

(32 Fader shown)

DESCRIPTION

1 Euphonix 32 Fader System 5 MC

1 Sonic Wall Pro 1260 DHCP Router/Ethernet Switch

1 Apple 20" Cinema Display

1 DVI Cable M-M

(included with Cinema Display packout)

6 Ethernet Cable

1 USB Memory Stick (for app sets and configuration data)

1 Apple G5 Workstation fitted:

1

DigiDesign ProTools LE7

(or higher)

1 DigiDesign 007 Rack

MC_PToolsLE_Install_AdditionalItems_V1-1 5/10/2006

F

E

D

C

B

A

H

G

WAN

USB

MEMORY STICK

WAN

NETGEAR

RP614

NET 1

NET 2

NET 3

NET 4

1 2

APPLE G5

Protools LE

NET 1

NET 2

DVI OUT

PCIe

USB

USB

USB

FW400

1

2

3

EUPHONIX

MC CONTROLLER

4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7

1

1

2

3

4

2

3

4

MIC

IN

LINE

IN

Digidesign

002 Rack

LINE

OUT

1

2

3

4

5

6

7

8

1

2

FIRE

WIRE

8 9 10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

B

A

D

C

F

E

H

G

USB

MEMORY STICK

1

APPLE G5

Pro Tools LE

NET 1

NET 2

DVI OUT

PCIe

USB

USB

USB

FW400

1

2

2 3

EUPHONIX SYSTEM

5MC

FADERS 1-8

EUPHONIX SYSTEM

5MC

FADERS 9-16

EUPHONIX

MC CONTROLLER

EUPHONIX SYSTEM

5MC

FADERS 17-24

EUPHONIX SYSTEM

5MC

FADERS 25-32

4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7

1

1

2

3

4

2

3

4

MIC

IN

LINE

IN

Digidesign

002 Rack

LINE

OUT

1

2

3

4

5

6

7

8

1

2

FIRE

WIRE

8 9

1

2

10

11

12

7

8

9

3

4

5

6

PORTS

SONIC WALL 1260

ROUTER/SWITCH

PORTS

13

14

22

23

24

19

20

21

15

16

17

18

10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

Pyramix / Euphonix Media Controller Installation

Required Parts

MC Only

QTY

1 Euphonix MC Controller

1 Apple 20" Cinema Display

1 Netgear RP614 DHCP Router/Switch

(included with MC packout)

1 DVI M-M

(included with Cinema Display packout)

2 Ethernet Cable

(included with MC packout)

1 USB Memory Stick (for app sets and configuration data)

1 Merging Pyramix Workstation fitted:

1 Pyramix 5.0

(or higher)

1 Pyramix OASIS License

1 Euphonix Nuendo EUCON License

1 Pyramix Compatible PCI Sound Card

QTY

System 5 MC

(32 Fader shown)

DESCRIPTION

1 Euphonix 32 Fader System 5 MC

1 Sonic Wall Pro 1260 DHCP Router/Ethernet Switch

1 Apple 20" Cinema Display

1 DVI Cable M-M

(included with Cinema Display packout)

6 Ethernet Cable

1 USB Memory Stick (for app sets and configuration data)

1 Merging Pyramix Workstation fitted:

1

Pyramix 5.0

(or higher)

1 Pyramix OASIS License

1 Euphonix Nuendo EUCON License

1 Pyramix Compatible PCI Sound Card

MC_PYRAMIX_Install_AdditionalItems_V1-1 5/10/2006

F

E

D

C

B

A

H

G

WAN

USB

MEMORY STICK

WAN

NETGEAR

RP614

NET 1

NET 2

NET 3

NET 4

1 2

Pyramix PC

V5.0

NET 1

DVI OUT

Pyramix

Sound

Card

FW400

1

2

USB

3

EUPHONIX

MC CONTROLLER

DVI IN

APPLE

CINEMA DISPLAY

USB

4 5 6 7 8 9 10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

B

A

D

C

F

E

H

G

USB

MEMORY STICK

EUPHONIX SYSTEM

5MC

FADERS 1-8

EUPHONIX SYSTEM

5MC

FADERS 9-16

EUPHONIX

MC CONTROLLER

EUPHONIX SYSTEM

5MC

FADERS 17-24

EUPHONIX SYSTEM

5MC

FADERS 25-32

1

Pyramix PC

V5.0

NET 1

DVI OUT

Pyramix

Sound

Card

FW400

1

2

USB

2 3 4 5

DVI IN

APPLE

CINEMA DISPLAY

USB

6 7 8

1

2

10

11

12

7

8

9

3

4

5

6

PORTS

SONIC WALL 1260

ROUTER/SWITCH

PORTS

13

14

22

23

24

19

20

21

15

16

17

18

9 10 11

Comments

Legend:

ANALOG

DVI

NETWORK

FIREWIRE

USB

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project