TTI Instruments LT 100 infrared thermometer Operating instructions

TTI Instruments LT 100 infrared thermometer Operating instructions

Below you will find brief information for infrared thermometer LT 100. The LT 100 is a non-contact infrared thermometer that measures temperatures from -60°C to +500°C. It has a 12:1 distance-to-spot ratio, a fixed emissivity of 0.95, and a response time of 1 second. The thermometer also features a real-time maximum (MAX) data display and a backlit LCD.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

LT 100 Infrared Thermometer Operating Instructions | Manualzz

L T 1 0 0 O p e r r a t t i i n g I I n s t t r r u c t t i i o n s

The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum (MAX) data.

Please remember to keep away from children and don’t use it for safety related applications.

(Default Screen)

1. Simply aim the thermometer at the measure target with Lens (○ ) and press Meas. key (○ ) to display the surface temperature.

2. During the measurement, the MAX reading will be displayed beside the icon.

3. The Distance:Spot is 12:1 . Please make sure the target area is within the field

of view.

ADD VALUE: o C or o F Press Mode key (○ ) for o C or o F transferred.

Backlight LCD Backlight: always on.

Laser ClassII Laser: always enable while measuring.

EMC/RFI

Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.

* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F).

CAUTION

1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE MAY RESULT.

2. USE EXTREME CAUTION WHEN OPERATING THE LASER.

3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.

4. KEEP OUT OF REACH OF ALL CHILDREN.

STORAGE & CLEANING

The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer. The thermometer should be stored at room temperature between –20 to

+65°C (-4~149°F).

LCD ERROR MESSAGES

The thermometer incorporates visual diagnostic messages as follows:

‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature. ‘Er3’ is displayed when the ambient temperature exceeds 0 temperature. o C(32°F) or +50 o C (122°F).

The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room

Error 5~9, for all other error messages it is necessary to reset the thermometer. To reset it, turn the instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error message remains please contact the Service Department for further assistance.

‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the measurement range.

BATTERIES

The thermometer incorporates visual low battery indication as follows:

‘Battery OK’: measurements

are possible

‘Battery Low’: battery needs to be replaced, measurements are still possible

‘Battery Exhausted’: measurements are not possible

When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA, 1.5V batteries.

Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction.

Dispose of used battery promptly and keep away from children.

SPECIFICATION

Measurement Range -60 to +500 o C (-76 to +932 o F)

Operating Range 0~50°C (32~122°F)

Accuracy, (Tobj=15-35°C,Tamb=25°C)

Accuracy (Tamb=23 +/- 3°C)

+/-1.0°C (1.8°F)

Tobj=0~500°C:+/-2% of reading or 2°C (4°F) whichever is greater

Tobj=-60~0 o C: +/-(2°C+0.05/degree)

Resolution (-9.9~199.9°C)

Response Time (90%)

0.1°C/0.1°F

1sec

Distance:Spot 12:1

Battery Life Typ.18, min 14 hours continuous use

Dimensions 175.2 x 39.0 x 71.9mm(6.9×1.54×2.83 inch)

Weight 179 grams(6.31 oz) including batteries (AAA*2pcs)

** The thermometer will automatically shut off if left idle for more than 15sec.

SERVICE

Instruments

8 Leroy Road

Williston, VT 05495

advertisement

Key Features

  • Non-contact measurement
  • Temperature range: -60°C to +500°C (-76°F to +932°F)
  • 12:1 distance-to-spot ratio
  • Real-Time Maximum (MAX) data
  • Backlit LCD
  • Auto shut-off after 15 seconds
  • Low battery indication

Frequently Answers and Questions

What is the accuracy of the LT 100 infrared thermometer?
The accuracy of the LT 100 infrared thermometer is +/-1.0°C (1.8°F) for temperatures between 15°C and 35°C. For other temperatures, the accuracy is +/-2% of the reading or 2°C (4°F), whichever is greater.
How do I clean the lens of the LT 100 infrared thermometer?
To clean the lens, use only a soft cloth or cotton swab with water or medical alcohol. Allow the lens to dry completely before using the thermometer.
What should I do if the LT 100 infrared thermometer displays an error message?
If the thermometer displays an error message, you should first check the ambient temperature. If the temperature is outside of the operating range, allow the thermometer to stabilize to room temperature. If the error message persists, you may need to reset the thermometer. To reset the thermometer, turn the instrument off, remove the battery, wait for one minute, reinsert the battery, and turn it on. If the error message remains, contact the Service Department for further assistance.

Related manuals

Download PDF

advertisement