5163617-BTG-D-0616 TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONER / GAS HEAT 14 SEER – R-410A – 3 PHASE 3 THRU 5 NOMINAL TONS - 460V 50 THRU 125 MBH HEAT INPUT MODELS: PCG4*36 THRU 60 DESCRIPTION These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. FEATURES • Operating Efficiency - All PCG4 model gas units provide a minimum AFUE of 81.0% in heating and 14.0 SEER, 11.0 EER rating for cooling operation. All models meet California Low-Nox requirements of 40 ng/joule emission level for Air Quality Management Districts. • On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexibility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers during assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low crawl spaces without transition pieces. ® Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com Additional rating information can be found at: www.ahridirectory.org WARRANTY SUMMARY* Standard 1-Year limited parts warranty. Standard 5-Years limited compressor warranty. Lifetime gas heat exchanger warranty with registration. See limited warranty certificate in User’s Information Manual for details. • Utility Connections Made Easy - Gas and electric utility access provided through the bottom or the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 6289 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal. • Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel provides a better paintto-steel bond, which resists corrosion and rust creep. Powder paint finish insure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). Continued on next page. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 5163617-BTG-D-0616 • Outdoor Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each corner. • More Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. • Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. This allows compact location on multi-unit applications. • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. This design strategically places embossments in the pan for optimum strength and rigidity. • Fan System - All models operate over a wide range of design conditions with a standard ECM indoor fan motor. These units easily match all types of applications and provide greater on-site flexibility to match comfort requirements. The cooling speed is factory-set and can be field-adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions. • Simple Control Circuit - A low voltage gas heat printed circuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded wire leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-nlock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. 2 • Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. • Pressure Switches - A high pressure switch is standard in all units. When abnormal conditions are sensed through the pressure switch, the unit will lock out preventing any further operation until reset or problem is corrected. • Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability for long-lasting durability and efficient operation. Indoor coils use tin-coated copper tubing with aluminum fins for effective heat transfer. • Heat Exchangers - Gas heat exchangers use corrosionresistant, stainless-steel tubular construction to provide longlife, trouble-free operation. Gas heat exchangers are offered with lifetime warranties as standard with registration. • Post Purge Induced Draft Combustion - Exhausts combustion products from the heat exchanger upon completion of the heating cycle to prolong the heat exchanger life. • Spark To Burner Ignition - No pilot assembly required, which provides more consistent ignition in gas heating mode. This ignition is highly reliable, durable and eliminates nuisance lockouts. • Multi Port In-shot Burners - No field adjustment is required to mix the air and gas for natural gas or propane use. These burners are constructed of high-grade corrosion-resistant, aluminized steel. • Low Maintenance - Long life, permanently lubricated outdoor and evaporator fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly can be easily removed for cleaning. • Easy Service Access - Individual access panels covering the electrical and gas controls makes servicing easy. Removing this panel will allow easy removal of the blower assembly for maintenance and ease of troubleshooting. • Replacement Parts - The installer requires no special training to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts. • Loss of Charge Sensor (S1-2LC00024) - Kit provides Loss of Charge sensor and wiring to provide safe shutdown of compressor. • Transition Curb Kits (S1-1TC01*) - Adapter kits to allow field use of pre-existing installed roof curbs to match PCG4 footprint to Affinity roof curbs, Carrier, Trane, or Goodman curb footprints. Curb adapters are optional for current generation Carrier replacements but are recommended for previous generation applications. Refer to the PCG4 price pages for more details. Johnson Controls Unitary Products 5163617-BTG-D-0616 NOMENCLATURE PCG 4 A 24 050 3 X 1 A 1 2 3 4 5 6 7 8 9 1. Model Family PCG - packaged A/C with gas heat, PCE - packaged A/C with electric heat, PHE - packaged heat pump with electric heat PHG - packaged heat pump with gas heat. 5. Gas Heating Input BTU/Hr x 1000 050 = 50,000 BTU/Hr. input, blank = electric heat 2. Nominal Cooling Efficiency 4 = 14 SEER, 6 = 16 SEER, etc. 7. NOx Approval X = low-NOx, blank = not low-NOx 3. Cabinet Size A = small 35 x 51, B = large 45 x 51 8. Generation Level 1 = first generation 4. Nominal Air Conditioning Cooling Capacity 24 = Nominal Capacity, etc. 9. Revision Level A = original release, B = second release 6. Voltage-Phase-Frequency 2 = 208/230-1-60, 3=208/230-3-60, 4 = 460-3-60 Examples: PCG4B421003X1A is a packaged A/C with gas heat, 14 SEER, 3-1/2 ton, large cabinet, single-stage heat, 100,000 BTU gas heat, 230 volt, 3-phase, low-NOx model (first generation, first release). COMPONENT LOCATION FAN MOTOR OUTDOOR FAN COIL GUARD PANEL OUTDOOR COIL (Behind Panel) CONTROL BOARD TRANSFORMER BLOWER MOTOR HIGH VOLTAGE CONTACTOR TXV PRESSURE SWITCH INDOOR COIL DRAFT INDUCER BLOWER INDOOR BLOWER GAS VALVE COMPRESSOR GAS HEAT EXCHANGER REMOVABLE BASE RAILS BURNER ASSEMBLY A0297-001 UNIT LIMITATIONS Unit Limitations Model Unit Voltage Applied Voltage Outdoor DB Temp Min Max Max (°F) 432 504 125 PCG4A36 PCG4B48 460-3-60 PCG4B60 Johnson Controls Unitary Products 3 5163617-BTG-D-0616 ACCESSORIES • Propane Conversion Kit (S1-1NP0702, S1-1NP0701) - Kit includes burner orifices, gas valve conversion and installation instructions necessary to field convert unit from natural gas to propane. • Economizer for Downflow Applications (S1-2EE04708424, S1-2EE04708524) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. • Economizer for Horizontal Applications (S1-2EE04708624, S1-2EE04708724) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. • Single/Dual Enthalpy Sensor (S1-2EC04700624) - Sensor replaces dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. • CO2 Sensor Kit (S1-2AQ04700824) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Outdoor Temp. Sensor Kit (S1-2EC04700724S1-2EC04700724v) - Additional outdoor air temp sensor kit used with economizers. • Filter/Frame Kit (Kit provided) (S1-1FF0602, S1-1FF0601) - Kit contains the necessary hardware to field install return air filters into the base unit. The filter rack is suitable for either 1" or 2" filters. (filters not supplied). • Motorized Fresh Air Damper (S1-2MD04705224, S1-2MD04705124) - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. 4 • Rectangle to Round (Horizontal) Adapter (S1-1AK0110, S1-1AK0111) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current horizontal duct openings on the base unit. Transition is from rectangle to 12" round for the 1AK0110 kit and from rectangle to 14" round for the 1AK0111 kit. • Rectangle to Round (Downflow) Adapter (S1-1AK0108, S1-1AK0109) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit into current downflow duct openings on the roof curb. Transition is from rectangle to 16" round for the 1AK0108 kit and from rectangle to 18" round for the 1AK0109 kit. • Roof Curbs (S1-1RC0503, S1-1RC0501) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 8 inch high roof curbs. • Roof Curbs (S1-1RC0504, S1-1RC0502) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 14 inch high roof curbs. • Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) - Provides 0% through 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly. • Thermostat - Compatible thermostat controls are available through accessory sourcing. For optimum performance, these outdoor units are fully compatible with our residential touch screen thermostat with proprietary (patent-pending) hexagon interface. For more information, see the thermostat section of the Product Equipment Catalog. • Wall Thermostat - The units are designed to operate with standard, 24-volt electronic and electro-mechanical thermostats. All units can operate with single stage heat/single stage cool thermostats - with or without the economizer. • Low Ambient Kit (S1-2LA04700824) - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0º F. Standard unit operation 45º F. • Base Rail Hole Cover Kit (S1-1HC0101) - Kit provides necessary hardware to close off openings in base rails to block off openings, i.e. prevent animal entrance. Johnson Controls Unitary Products 5163617-BTG-D-0616 GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. Package units give you the flexibility and choices you need in today’s market. These packaged cooling/ heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. The single-stage gas fired heaters have stainless steel tubular heat exchangers and spark to burner ignition. They are available in natural gas with field conversion to propane. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heating units, designed for outdoor installation. For SEER ratings, refer to technical literature. They shall have built in, equal size, field convertible duct connections for supply/ return or horizontal supply/return. The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All models shall be rated in accordance with DOE and AHRI test procedures for both heating and cooling operation. Units shall be CSA listed and classified to ANSI Z21.47/CAN/ CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of G-90 galvanized, powderpainted steel, certified at 1000 hours salt spray test per ASTMB117 standards. The unit top shall be a single piece design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted outdoor coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with foil-faced or foam insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be separate, easily removable for servicing and maintenance. Unit shall be built on a formed, design base pan, with embossments at critical points to add strength and rigidity and to aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for truck access and proper sealing on roof curb applications. Base rails shall be easily removable, when required to lower unit height. Filters shall be field installed, furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24” O.C. beams without modification to building structure, duct work and base unit. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards, with 3/4” NPT female ridged mount connection. Indoor Blower Assembly - Fan shall be direct drive design. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be a slide-out design for easy removal and cleaning. Indoor blower motors shall be equipped with a standard high efficiency brushless DC motor (constant torque) also known as a standard ECM motor. Johnson Controls Unitary Products Outdoor Fan Assembly - The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. b. Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Indoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced tin-coated copper tubes with all joints brazed. b. Indoor coil shall be of the direct expansion, draw through design. c. Outdoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. d. Outdoor coil shall be draw through design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Thermal expansion devices (TXV's) shall be factory mounted and provided. b. Filter/strainer to eliminate any foreign matter. GAS HEATING SECTION Heat exchanger and exhaust system shall be constructed of corrosion-resistant materials and shall be designed with induced draft combustion with post purge logic and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 ºF. Burners shall be of the in-shot type, constructed of aluminumized steel. All gas piping shall enter the unit cabinet at a single location through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of indoor fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary high-temperature limit switch. b. Induced draft pressure switch. c. Flame roll out switch(s) (manual reset). d. Flame proving controls. All gas heat models will meet the California requirement for emissions of less than 40 nanograms per Joule. 5 5163617-BTG-D-0616 PHYSICAL DATA COMPONENT NOMINAL TONNAGE PCG4A36 3.0 MODELS PCG4B48 4.0 PCG4B60 5.0 37.2 34.6 11.0 14.0 1200 3.2 R410A 8-3 47.7 45.5 11.0 14.0 1600 4.2 R410A 14-4 55.0 52.5 11.0 14.0 2000 4.8 R410A 14-2 Filters AHRI Cooling Performance Gross Capacity @ AHRI A point (MBH) AHRI net capacity (MBH) EER SEER Nominal CFM System power (KW) Refrigerant type Refrigerant charge (lb-oz) AHRI Gas Heat Performance Heating model Heat input (K Btu) Heat output (K Btu) AFUE% No. burners No. stages Temperature Rise Range (°F) Max. Static Pressure w.c. Max. Outlet Air Temp. (°F) Gas piping connection (in.) Dimensions (inches) Length Width Height Operating WT. (lbs.) Compressors Type Outdoor Coil Data Face area (Sq. Ft.) Rows Fins per inch Tube diameter Circuitry Type Indoor Coil Data Face area (Sq. Ft.) Rows Fins per inch Tube diameter Circuitry Type Refrigerant control Outdoor Fan Data Fan diameter (Inch) Type Drive type No. speeds Motor HP each RPM Nominal total CFM Direct Drive Indoor Fan Data Fan Size (Inch) Type Motor HP each RPM Frame size Filters Quantity - Size 6 50 50.0 40 2 35-65 420 1/2 75 75.0 60 81.0 3 1 40-70 0.5 180 1/2 51-1/4 35-3/4 47 427 100 100.0 80 65 65.0 52 4 2 40-70 431 515 100 100.0 80 81.0 3 1 40-70 0.5 180 1/2 51-1/4 45-3/4 53 523 125 125.0 100 65 65.0 52 4 2 528 532 100 100.0 80 81.0 3 1 40-70 0.5 180 1/2 51-1/4 45-3/4 55 536 Recip Scroll Scroll 15.1 2 22 3/8 Interlaced 23.8 2 22 3/8 Interlaced 25.9 2 22 3/8 Interlaced 4.6 3 16 3/8 Interlaced TXV 6.3 3 16 3/8 Interlaced TXV 6.3 3 16 3/8 Interlaced TXV 24 Prop Direct 1 1/4 850 2400 26 Prop Direct 1 1/3 850 3200 26 Prop Direct 1 1/3 850 3200 11 x 10 Centrifugal 1/2 1200 Max 48 11 x 10 Centrifugal 1 1200 Max 48 11 x 10 Centrifugal 1 1200 Max 48 1 125 125.0 100 4 543 Field-supplied external filters must be sized so as not to exceed 300 FPM air velocity through disposable filters. All 3-phase models are shipped with an internal filter rack kit. Consult the instructions supplied with that kit for replacement filter sizes. Filter sizes: A=20x20, B=20x30. Johnson Controls Unitary Products 5163617-BTG-D-0616 COOLING PERFORMANCE DATA - 3 TON PACKAGED UNIT MODEL NO. PCG4A36 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 45.3 48.1 55 / 45 S.C. 45.3 43.2 K.W. 2.15 2.16 T.C. 42.0 43.7 65 / 55 S.C. 42.0 40.3 K.W. 2.39 2.41 T.C. 38.7 39.3 75 / 63 S.C. 38.7 37.4 K.W. 2.63 2.66 T.C. 35.3 35.4 85 / 69 S.C. 35.3 34.4 K.W. 2.87 2.90 T.C. 31.9 31.5 95 / 75 S.C. 31.9 31.5 K.W. 3.11 3.14 T.C. 26.5 26.8 105 / 83 S.C. 26.5 26.8 K.W. 3.43 3.39 T.C. 21.4 22.3 115 / 89 S.C. 21.4 22.3 K.W. 3.74 3.65 T.C. 16.2 17.7 125 / 95 S.C. 16.2 17.7 K.W. 4.05 3.90 1400 75 62 48.0 36.0 2.16 43.8 34.1 2.40 39.6 32.1 2.64 35.5 30.0 2.88 31.5 28.0 3.12 26.3 24.0 3.35 21.3 20.2 3.57 16.3 16.3 3.79 80 67 53.1 36.5 2.15 48.6 34.5 2.41 44.1 32.4 2.67 39.4 30.1 2.93 34.8 27.8 3.20 29.0 24.4 3.43 23.4 21.1 3.67 17.7 17.7 3.90 80 72 54.6 27.9 2.15 52.4 26.6 2.40 50.1 25.4 2.65 45.0 23.6 2.93 39.8 21.8 3.21 33.7 19.3 3.48 27.7 17.0 3.75 21.7 14.6 4.01 80 57 42.2 42.2 2.07 39.4 39.4 2.30 36.6 36.6 2.52 33.6 33.6 2.75 30.5 30.5 2.99 26.0 26.0 3.27 21.6 21.6 3.54 17.2 17.2 3.81 80 62 46.3 39.5 2.07 42.5 36.9 2.31 38.6 34.3 2.55 34.8 32.0 2.79 31.0 29.7 3.02 26.5 25.7 3.27 22.2 21.8 3.50 17.9 17.9 3.74 1200 75 62 46.2 33.3 2.07 42.4 31.3 2.31 38.5 29.3 2.54 34.8 27.5 2.77 31.0 25.7 3.00 26.2 22.6 3.23 21.4 19.7 3.44 16.7 16.7 3.66 80 67 51.3 33.4 2.06 47.1 31.5 2.32 42.9 29.5 2.57 38.7 27.5 2.83 34.6 25.5 3.08 29.1 22.8 3.32 23.8 20.2 3.54 18.5 17.6 3.77 80 72 53.5 26.1 2.05 51.0 24.9 2.31 48.4 23.6 2.56 43.8 21.9 2.83 39.2 20.2 3.10 33.5 18.0 3.37 28.0 15.9 3.63 22.5 13.8 3.88 80 57 39.2 39.2 1.99 36.8 36.8 2.20 34.5 34.5 2.41 31.9 31.9 2.64 29.2 29.2 2.87 25.5 25.5 3.11 21.8 21.8 3.34 18.2 18.2 3.57 80 62 44.6 35.8 1.99 41.2 33.5 2.22 37.9 31.1 2.45 34.2 29.5 2.68 30.5 27.9 2.91 26.3 24.5 3.14 22.2 21.3 3.36 18.0 18.0 3.58 1000 75 62 44.5 30.6 1.99 41.0 28.6 2.22 37.4 26.6 2.44 34.0 25.0 2.67 30.6 23.4 2.89 26.0 21.2 3.11 21.5 19.1 3.32 17.0 17.0 3.53 80 67 49.5 30.4 1.97 45.6 28.5 2.22 41.7 26.7 2.47 38.0 25.0 2.72 34.3 23.3 2.97 29.2 21.3 3.20 24.2 19.3 3.42 19.2 17.4 3.65 80 72 52.4 24.4 1.95 49.5 23.1 2.21 46.7 21.8 2.46 42.7 20.2 2.73 38.6 18.7 2.99 33.4 16.7 3.25 28.3 14.8 3.50 23.2 13.0 3.76 80 67 66.8 44.1 2.23 62.2 42.4 2.49 57.6 40.6 2.75 52.4 38.1 3.08 47.2 35.6 3.41 40.9 33.3 3.88 34.9 31.0 4.33 28.8 28.8 4.79 80 72 70.0 33.9 2.25 66.3 32.4 2.50 62.5 30.9 2.76 57.6 28.7 3.09 52.7 26.5 3.42 46.8 24.7 3.89 41.1 23.0 4.35 35.5 21.2 4.80 80 57 55.6 54.5 2.20 52.1 51.6 2.44 48.7 48.7 2.69 44.6 44.6 3.04 40.6 40.6 3.38 36.1 36.1 3.85 31.7 31.7 4.30 27.3 27.3 4.76 80 62 59.5 49.9 2.21 55.1 48.0 2.46 50.7 46.0 2.72 46.0 42.9 3.05 41.3 39.8 3.38 36.2 35.2 3.85 31.2 30.7 4.31 26.2 26.2 4.77 1600 75 62 58.7 42.1 2.20 54.4 40.1 2.45 50.1 38.2 2.71 45.1 35.5 3.04 40.2 32.9 3.38 35.0 30.1 3.85 30.1 27.3 4.30 25.1 24.6 4.76 80 67 65.1 41.9 2.23 60.9 40.2 2.49 56.6 38.5 2.75 51.5 35.9 3.08 46.4 33.4 3.41 40.6 31.3 3.88 35.1 29.3 4.33 29.6 27.4 4.79 80 72 70.0 33.5 2.24 65.7 31.5 2.49 61.4 29.5 2.75 56.8 27.5 3.09 52.2 25.4 3.42 46.5 23.7 3.89 41.0 22.0 4.34 35.6 20.3 4.80 80 57 53.1 51.9 2.18 49.8 49.2 2.43 46.5 46.5 2.68 42.8 42.8 3.02 39.0 39.0 3.36 34.9 34.9 3.84 30.9 30.9 4.30 27.0 27.0 4.76 80 62 57.5 46.3 2.20 53.4 44.5 2.46 49.3 42.6 2.71 44.9 40.0 3.05 40.5 37.4 3.38 35.4 33.4 3.86 30.5 29.5 4.31 25.5 25.5 4.77 1400 75 62 57.2 39.7 2.19 53.1 37.9 2.45 49.0 36.0 2.70 44.1 33.3 3.03 39.2 30.7 3.37 34.8 28.9 3.84 30.6 27.1 4.30 26.4 25.4 4.76 80 67 63.4 39.6 2.22 59.5 38.0 2.48 55.6 36.3 2.74 50.6 33.8 3.07 45.5 31.2 3.40 40.3 29.4 3.87 35.3 27.6 4.33 30.3 25.9 4.79 80 72 69.9 33.0 2.23 65.1 30.6 2.49 60.3 28.2 2.74 56.0 26.3 3.08 51.7 24.3 3.42 46.2 22.7 3.88 41.0 21.0 4.34 35.7 19.4 4.79 COOLING PERFORMANCE DATA - 4 TON PACKAGED UNIT MODEL NO. ID CFM CONDENSER ENTERING AIR IDDB TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PCG4B48 80 57 58.1 57.1 2.21 54.4 54.0 2.46 50.8 50.8 2.71 46.5 46.5 3.05 42.2 42.2 3.39 37.2 37.2 3.85 32.4 32.4 4.31 27.6 27.6 4.76 Johnson Controls Unitary Products 80 62 61.5 53.6 2.21 56.8 51.5 2.47 52.2 49.5 2.73 47.2 45.8 3.06 42.2 42.2 3.38 37.0 37.0 3.85 31.9 31.9 4.31 26.9 26.9 4.76 1800 75 62 60.2 44.4 2.20 55.7 42.4 2.46 51.2 40.4 2.72 46.2 37.7 3.05 41.2 35.0 3.38 35.3 31.2 3.85 29.6 27.5 4.30 23.9 23.9 4.76 7 5163617-BTG-D-0616 COOLING PERFORMANCE DATA - 5 TON PACKAGED UNIT MODEL NO. ID CFM CONDENSER ENTERING AIR IDDB TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. 8 PCG4B60 80 57 63.1 63.1 3.44 59.1 59.1 3.74 55.1 55.1 4.03 27.6 27.6 4.42 47.5 47.5 4.80 43.0 43.0 5.37 38.6 38.6 5.92 34.2 34.2 6.47 80 62 65.4 58.0 3.44 61.9 57.3 3.75 58.3 56.5 4.05 53.5 52.6 4.44 48.7 48.7 4.84 44.0 44.0 5.40 39.6 39.6 5.96 35.1 35.1 6.51 2050 75 62 65.2 49.1 3.43 28.9 23.1 3.74 57.7 46.1 4.05 52.8 43.8 4.45 47.9 41.5 4.84 39.9 35.7 5.41 32.1 30.0 5.97 24.4 24.4 6.53 80 67 68.7 46.2 3.43 32.9 23.1 3.76 65.7 46.2 4.09 60.0 44.0 4.48 54.3 41.8 4.86 46.0 37.8 5.42 38.0 33.9 5.96 30.0 30.0 6.49 80 72 72.9 34.9 3.41 36.7 17.6 3.76 73.2 35.2 4.11 60.4 41.4 4.47 47.5 47.5 4.83 44.7 39.3 5.41 42.0 31.3 5.98 39.3 23.4 6.55 80 57 60.4 60.4 3.28 56.7 56.7 3.57 53.0 53.0 3.87 26.5 26.5 4.26 46.0 46.0 4.66 41.5 41.5 5.23 37.1 37.1 5.79 32.7 32.7 6.35 80 62 64.1 54.7 3.29 60.5 53.5 3.59 56.9 52.3 3.88 52.5 49.3 4.28 48.1 46.3 4.68 42.6 41.4 5.25 37.2 36.6 5.80 31.9 31.9 6.35 1800 75 62 64.4 46.3 3.33 28.4 21.5 3.61 56.7 43.0 3.89 52.2 40.9 4.29 47.8 38.8 4.69 40.0 34.1 5.26 32.5 29.5 5.82 25.0 25.0 6.38 80 67 68.0 44.2 3.34 32.2 21.6 3.63 64.4 43.1 3.92 59.2 41.1 4.31 54.0 39.0 4.71 46.1 35.6 5.26 38.5 32.2 5.81 31.0 28.8 6.35 80 72 71.8 33.9 3.32 36.0 16.8 3.64 72.0 33.6 3.96 63.2 35.7 4.33 54.3 37.9 4.70 49.5 32.5 5.27 44.8 27.4 5.83 40.1 22.2 6.38 80 57 57.6 57.6 3.12 54.3 54.3 3.41 51.0 51.0 3.70 25.5 25.5 4.11 44.4 44.4 4.51 40.0 40.0 5.10 35.6 35.6 5.66 31.2 31.2 6.23 80 62 62.7 51.4 3.14 59.1 49.7 3.43 55.5 48.1 3.72 51.5 46.0 4.12 47.5 43.9 4.52 41.1 38.7 5.09 34.9 33.7 5.64 28.7 28.7 6.19 1550 75 62 63.6 43.4 3.23 27.9 20.0 3.48 55.7 40.0 3.73 51.6 38.0 4.13 47.6 36.1 4.53 40.1 32.5 5.11 32.9 29.1 5.67 25.6 25.6 6.24 80 67 67.2 42.2 3.24 31.6 20.0 3.50 63.1 40.0 3.76 58.4 38.1 4.15 53.6 36.3 4.55 46.2 33.3 5.11 39.0 30.5 5.66 31.9 27.6 6.21 80 72 70.6 32.8 3.23 35.4 16.0 3.52 70.7 32.0 3.80 65.9 30.1 4.19 61.1 28.2 4.57 54.3 25.7 5.13 47.6 23.4 5.67 41.0 21.0 6.21 Johnson Controls Unitary Products 5163617-BTG-D-0616 COIL GUARD HIGH VOLTAGE CONNECTION 7/8” C HIGH VOLTAGE CONNECTION 1-3/32” COMBUSTION AIR INTAKE HEAT EXCHANGER ACCESS PANEL COMPRESSOR ACCESS PANEL EXHAUST HOOD CONDENSATE DRAIN BLOWER ACCESS PANEL A B LOW VOLTAGE CONNECTION GAS SUPPLY CONTROL / HEAT ACCESS PANEL A0296-001 UNIT DIMENSIONS Dimensions Model A PCG4A36 PCG4B48 51-1/4 PCG4B60 B C 35-3/4 47 45-3/4 53 45-3/4 55 UNIT CLEARANCES1,2 1. 2. 3. 4. Direction Distance (in.) Direction Top3 36 Power Entry (Right Side) Distance (in.) 36 Side Opposite Ducts 36 Left Side 24 Duct Panel 0 Bottom4 1 A 1" clearance must be provided between any combustible material and the supply air duct work. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Units must be installed outdoors. Over hanging structure or shrubs should not obstruct condenser air discharge outlet. Units may be installed on combustible floors made from class A, B or C roof covering materials only if factory base rails are left in place as shipped. INDOOR BLOWER SPECIFICATIONS Model Motor HP 36050 1/2 36075 1/2 36100 1 48065 1 48100 1 48125 1 60065 1 60100 1 60125 1 Johnson Controls Unitary Products RPM EFF. SF Frame Variable 0.8 1.0 48 9 5163617-BTG-D-0616 SOUND PERFORMANCE Model (Tons) Sound Rating1 dB (A) 125 250 500 1000 2000 4000 8000 PCG4A36 74 58.5 61.8 65.4 66.5 60.7 54.8 49.8 PCG4B48 74 63.5 63.9 62.3 65.0 64.0 54.1 46.6 PCG4B60 76 72.3 65.0 63.9 64.0 60.0 55.5 49.0 Octave Band Centerline Frequency (Hz) 1. Rated in accordance with AHRI Standard 270. ELECTRICAL DATA - 460-3-60 Model Compressor Voltage OD Fan Motor Supply Blower Motor MCA1 (Amps) Max Fuse2/ Breaker3 Size (Amps) RLA LRA MCC FLA FLA 36050, 36075 4.1 34.0 7.6 0.70 1.95 7.8 36100 4.1 34.0 7.6 0.70 3.15 9.0 15 6.2 41.0 9.7 0.87 3.15 11.8 15 7.8 52.0 12.1 0.87 3.15 13.8 20 460-3-60 48065, 48100, 48125 60065, 60100, 60125 15 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size. "D" CENTER OF GRAVITY COMPRESSOR "C" "A" FRONT OF UNIT Y "B" X A0295-001-TG WEIGHTS AND DIMENSIONS Model 10 Weight (lbs.) Center of Gravity 36050 Shipping 425 Operating 420 X 28 36075 432 427 36100 436 431 48065 520 48100 48125 Y 4 Point Load Location (lbs.) A 141 B 107 C 94 D 78 28 135 115 103 74 28 139 113 99 80 515 28 189 116 93 117 528 523 28 169 139 115 100 533 528 28 164 145 124 95 60065 537 532 29 174 142 124 92 60100 541 536 28 177 140 117 102 60125 548 543 27 151 167 141 84 15 Johnson Controls Unitary Products 5163617-BTG-D-0616 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION External Static Pressure (Inches WC) Model 36050 36075 36100 48065 48100 48125 60065 60100 60125 Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 1003 952 904 851 790 730 674 633 551 Low/Medium (2) 1180 1133 1085 1042 995 942 889 834 724 Medium (3) 1259 1209 1166 1126 1084 1032 980 928 824 Medium/High (4) 1314 1271 1229 1186 1144 1097 1049 998 896 High (5) 1506 1471 1403 1389 1345 1305 1262 1216 1124 Low (1) 1225 1174 1131 1090 1046 993 941 888 782 Low/Medium (2) 1259 1209 1166 1126 1084 1032 980 928 824 Medium (3) 1314 1271 1229 1186 1144 1097 1049 998 896 Medium/High (4) 1348 1306 1259 1222 1179 1133 1086 1036 936 High (5) 1506 1471 1403 1389 1345 1305 1262 1216 1124 Low (1) 1342 1302 1260 1217 1178 1134 1082 1034 938 Low/Medium (2) 1425 1368 1332 1293 1251 1208 1163 1113 1013 Medium (3) 1554 1503 1465 1423 1386 1346 1302 1257 1167 Medium/High (4) 1658 1599 1588 1530 1495 1454 1414 1373 1291 High (5) 1966 1914 1862 1810 1757 1705 1653 1600 1496 Low (1) 1046 1009 980 946 915 878 844 779 649 Low/Medium (2) 1295 1250 1213 1172 1133 1087 1045 964 802 Medium (3) 1620 1564 1517 1466 1418 1360 1308 1206 1002 Medium/High (4) 1798 1722 1669 1620 1572 1527 1480 1413 1280 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 1609 Low (1) 1620 1564 1517 1466 1418 1360 1308 1206 1002 Low/Medium (2) 1694 1630 1580 1530 1482 1430 1380 1292 1116 Medium (3) 1798 1722 1669 1620 1572 1527 1480 1413 1280 Medium/High (4) 1835 1758 1703 1653 1604 1558 1511 1442 1304 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 1609 Low (1) 1620 1564 1517 1466 1418 1360 1308 1206 1002 Low/Medium (2) 1798 1722 1669 1620 1572 1527 1480 1413 1280 Medium (3) 1922 1863 1804 1754 1724 1658 1612 1559 1453 Medium/High (4) 2001 1952 1890 1839 1820 1742 1696 1651 1561 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 1609 Low (1) 1073 1043 1009 988 963 941 917 892 842 Low/Medium (2) 1329 1292 1250 1223 1192 1165 1136 1105 1043 Medium (3) 2054 1998 1934 1890 1843 1801 1757 1710 1616 Medium/High (4) 2195 2144 2098 2049 2003 1955 1883 1868 1838 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 1973 Low (1) 1730 1682 1628 1592 1552 1517 1479 1439 1359 Low/Medium (2) 1858 1807 1749 1710 1667 1629 1589 1546 1460 Medium (3) 2054 1998 1934 1890 1843 1801 1757 1710 1616 Medium/High (4) 2195 2144 2098 2049 2003 1955 1883 1868 1838 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 1973 Low (1) 2063 2008 1943 1899 1851 1809 1763 1717 1625 Low/Medium (2) 2130 2084 2032 1983 1927 1951 1860 1815 1725 Medium (3) 2195 2144 2098 2049 2003 1955 1883 1868 1838 Medium/High (4) 2275 2252 2169 2154 2112 2065 1989 1976 1950 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 1973 1. Airflow tested with dry coil conditions, without air filters, at 460 volts 2. Applications above 0.8" w.c. external static pressure are not recommended. 3. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. 4. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 11 5163617-BTG-D-0616 AIRFLOW PERFORMANCE - BOTTOM DUCT APPLICATION External Static Pressure (Inches WC) Model 36050 36075 36100 48065 48100 48125 60065 60100 60125 Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 1008 962 916 861 807 757 700 650 550 Low/Medium (2) 1190 1148 1106 1055 1008 955 914 863 761 Medium (3) 1262 1223 1181 1137 1091 1044 994 952 868 Medium/High (4) 1324 1282 1245 1202 1161 1112 1067 1018 920 High (5) 1517 1475 1447 1400 1357 1318 1275 1232 1146 Low (1) 1231 1186 1146 1103 1069 1030 977 912 781 Low/Medium (2) 1270 1225 1189 1140 1098 1046 1008 960 866 Medium (3) 1317 1286 1245 1198 1151 1110 1064 1024 943 Medium/High (4) 1358 1317 1275 1238 1197 1148 1105 1057 961 High (5) 1517 1475 1447 1400 1357 1318 1275 1232 1146 Low (1) 1340 1299 1264 1224 1182 1182 1097 1049 953 Low/Medium (2) 1409 1368 1334 1291 1253 1201 1173 1128 1038 Medium (3) 1527 1492 1470 1419 1385 1343 1299 1250 1152 Medium/High (4) 1663 1585 1594 1601 1521 1480 1440 1400 1320 High (5) 1930 1892 1853 1805 1760 1696 1625 1553 1409 Low (1) 1032 999 970 938 910 879 843 808 737 Low/Medium (2) 1272 1236 1204 1165 1129 1081 1037 968 829 Medium (3) 1611 1574 1518 1494 1439 1405 1357 1266 1083 Medium/High (4) 1892 1777 1771 1701 1639 1617 1565 1489 1336 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 1608 Low (1) 1598 1548 1502 1454 1410 1362 1307 1251 1139 Low/Medium (2) 1663 1612 1568 1522 1476 1422 1370 1297 1152 Medium (3) 1789 1733 1670 1650 1596 1578 1535 1483 1379 Medium/High (4) 1931 1814 1808 1736 1673 1650 1597 1519 1362 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 1608 Low (1) 1598 1548 1502 1454 1410 1362 1307 1251 1139 Low/Medium (2) 1766 1703 1656 1611 1566 1518 1469 1419 1319 Medium (3) 1912 1875 1805 1787 1750 1713 1672 1636 1564 Medium/High (4) 2105 2014 2006 1931 1898 1845 1793 1739 1631 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 1608 Low (1) 1026 999 989 950 907 907 886 862 816 Low/Medium (2) 1263 1230 1192 1165 1167 1101 1099 1071 1015 Medium (3) 1987 1933 1861 1817 1820 1715 1725 1651 1504 Medium/High (4) 2114 2050 2047 1974 1899 1889 1920 1866 1758 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 1902 Low (1) 1655 1612 1596 1531 1461 1462 1429 1391 1316 Low/Medium (2) 1766 1720 1667 1629 1632 1539 1537 1498 1421 Medium (3) 1987 1933 1861 1817 1820 1715 1725 1651 1504 Medium/High (4) 2114 2050 2047 1974 1899 1889 1920 1866 1758 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 1902 Low (1) 1973 1924 1905 1826 1743 1744 1703 1660 1574 Low/Medium (2) 2024 1983 1937 1889 1886 1843 1799 1759 1679 Medium (3) 2123 2075 2019 1970 1978 1862 1849 1804 1714 Medium/High (4) 2191 2154 2117 2075 2002 1995 2028 1974 1866 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 1902 1. Airflow tested with dry coil conditions, without air filters, at 460 volts 2. Applications above 0.8" w.c. external static pressure are not recommended. 3. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. 4. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. 12 Johnson Controls Unitary Products 5163617-BTG-D-0616 ADDITIONAL STATIC RESISTANCE Size (Tons) A36 (3.0) B48 (4.0) B60 (5.0) CFM Wet Indoor Coil 700 800 900 1000 1100 1200 1300 1400 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 1 BOTTOM DUCT DIMENSIONS (Inches) Economizer Filter/Frame Kit 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.18 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 D 16 1.75 C RETURN AIR DUCT A E B SUPPLY AIR DUCT A F Model 36 48, 60 A 10 14 A0298-001 B 21.5 13.5 C 5 D 4.5 3.5 E F 32 42 47.5 REAR DUCT DIMENSIONS (Inches) NOTE: Filter pressure drop based on standard filter media tested at velocities not to exceed 300 ft/min. 1.The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the u.nit will deliver less CFM during full economizer operation. 6833/< $,5'8&7 5(7851 $,5'8&7 $ $ Model 36 48, 60 Johnson Controls Unitary Products % A 9.6 13.6 $ B 22 14 13 5163617-BTG-D-0616 UNIT TYPICAL DUCT APPLICATIONS ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A032 UNIT TYPICAL SLAB ON GROUND INSTALLATION TO POWER SUPPLY RETURN AIR DUCT SUPPLY AIR DUCT FIELD-SUPPLIED DISCONNECT SWITCH CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE TO GAS SUPPLY LINE 14 CONTROL WIRING TO INDOOR THERMOSTAT A0325-001 Johnson Controls Unitary Products 5163617-BTG-D-0616 UNIT TYPICAL ROOF CURB INSTALLATION ROOF CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE ROOF CURB FIELD-SUPPLIED DISCONNECT SWITCH TO GAS SUPPLY LINE TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT RETURN AIR DUCT SUPPLY AIR DUCT A0326-001 EXTERNAL STATIC PRESSURE SETUP To measure external static pressure: • • • • • • Measure the supply air static pressure Record this positive number Measure the return air static pressure Record this negative number Treat the negative number as a positive and add the two numbers together This is total system static Johnson Controls Unitary Products 15 NOTES Subject to change without notice. Published in U.S.A. Copyright © 2016 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 5163617-BTG-D-0616 Supersedes: 5163617-BTG-C-0216
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement