Control equipment Type Код CRM-82TO 002470074 U t t U t Weight [g] 93 EVE Delay OFF without supply voltage CRM-82TO Packaging [pcs] 1/10 e - Off Delay (S break) a - Delay OFF (S break) the power supply is switched off (min. time is 0.5 s) Multifunction time relay CRM-91H, CRM-93H Advantages < 1-module, DIN rail mounted < Universal supply voltage: AC/DC 12V - 240V < 10 functions: - 5 time functions controlled via supply voltage - 4 time functions controlled via control input - 1 function of memory (latching) relay < Time scale 0.1 s - 10 days divided into 10 ranges < User-friendly setting of functions and time via rotary switch < Output contact: CRM-91H 1x16A changeover CRM-93H 3x8A changeover < Output indication: multifunction red LED, flashing at certain states Functions a) Delay ON after energisation b) Delay OFF after energisation c) Cycler beginning with pause after energisation d) Cycler beginning with impulse after energisation e) Delay OFF after de-energisation, instant make of output f) Delay OFF responding to make of control contact regardless its length g) Delay OFF after break of control contact with instant output h) Delay OFF after make and break of control contact i) Memory (latching) relay j) Pulse generator technical data on page 351 45 EVE Control equipment Multifunction time relay CRM-91H, CRM-93H Type In Code No. [A] CRM-91H 16 002470001 CRM-93H 8 002470002 Weight [g] 68 93 Packaging [pcs] 1/10 1/10 Time relay CRM-2H Advantages < 1-module, DIN rail mounted < Universal supply voltage: AC/DC 12V - 240V < 2 time functions: - cycler beginning with pulse - cycler beginning with pause < Time scale 0.1s - 100 days divided into 10 time ranges < Rough time setting by rotary switch < Output contact: 1x 16 A changeover < Output indication: multifunction red LED Time relay CRM-2H Type CRM-2H In [A] 16 Cycler beginning with pulse 46 Code No. 002470003 Weight [g] 68 Packaging [pcs] 1/10 Cycler beginning with pause technical data on page 352, 353 Control equipment EVE Delay ON star/delta relay CRM-2T Advantages 1-module, DIN rail mounting Supply voltage: AC/DC 12V - 240 V Generates motor starting cycle star-delta Time t1 (star) - time scale 0.1 s - 100 days is divided into 10 time ranges - rough time setting by rotary switch - fine time setting by potentiometer (from 0,1 to1) Time t2 (delay) between star/delta: - time range 0.1 s - 1 s is set by potentiometer Output contact: 2x 16 A (AC1) Output indication: multifunction red LED Delay ON star/delta relay CRM-2T Type In Code No. [A] CRM-2T UNI 3 002470013 Weight [g] 95 Packaging [pcs] 1/10 Delay ON star/delta U 15-18 25-28 t1 t2 Staircase switch CRM-4 Advantages < 1-module, DIN rail mounted < Supply voltage: AC 230 V < Protection against control push-button blocking < Time range: 0,5 -10 min < Selector switch: - AUTO: normal function acc. to set time - OFF: permanent off - ON: permanent on < Time setting via potentiometer < Output contact: 1x 16 A changeover ( load up to 4000 VA/AC1) Staircase switch CRM-4 Type In [A] CRM-4 16 technical data on page 354. 355 Code No. 002470012 Weight [g] 53 Packaging [pcs] 1/10 47 EVE Multifunction time relay CRM-91H, CRM-93H Connection Technical data CRM-91H Number of functions Supply Supply voltage Consumption Supply indication Time ranges Time settings Time deviation Repeat accuracy Temperature coefficient Output Changeover contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Controlling voltage Consumption of output Load between S-A2 Glow-tubes Control. terminals Impulse length Reset time Operating temperature Storing temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards CRM-93H 10 A1-A2 AC/DC 12-240 V (AC 50-60 Hz) AC 0,7-3 VA / DC 0,5 - 1,7 W green LED 0.1 s-10 days rotary switch 5%-mechanical setting 0,2%-set value stability 0,01% / °C at 20 °C 1 3 16 A / AC1 8 A / AC1 4000 VA / AC1, 2000 VA / AC1, 384 W /DC 192 W / DC 30 A / <3 s 10 A / <3 s 250 V AC1 / 24 V DC 500 mW multifunction red LED 3x107 0,7x105 AC/DC 12-240 V AC 0,025-0,2 VA / DC 0,1-0,7 W yes no A1-S min. 25 ms/ max. unlimited max. 150 ms -20...+55 °C -30...+70 °C 4 kV any DIN rail EN 60715 IP 40 from frontal panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 61812-1, EN 61010-1 CRM91-H CRM-93H Load with control input possible. Load between S-A2 possible to connect in parallel way, without disturbing of proper operation of the relay. Dimensions CRM-91H CRM-93H CRM-2H 1-MODULEdesign DESIGN 1-module MR-41 MR-42 351 DATA CRM-4 EVE Functions a) Delay ON after energisation b) Delay OFF after energisation c) Cycler beginning with pause after energisation d) Cycler beginning with impulse after energisation e) Delay OFF after de-energisation, instant make of output f) Delay OFF responding to make of control contact regardless its length g) Delay OFF after break of control. contact with instant output h) Delay OFF after make and break of control. contact i) Memory (latching) relay j) Pulse generator Description Time ranges Supply terminals Control. input S day Supply indicator Rough time setting Output indication - multifunction LED Examples of signalling Function: days Fine time setting Function setting Function: only ON Output contact DATA only OFF 352 EVE Time relay CRM-2H Technical data Connection Number of functions Supply 10 1 h 1 10 Supply voltage Consumption Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient Output Changeover contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Reset time Operating temperature Storage temperature Electrical strength Operating position Mounting/DIN rail Protection degree Overvoltage category Pollution degree Max. cable size h h 1 10 1 10 m m 10Dimensions 10 1 d 1 1 10 10 Standards30 10 S S 1 d 10 10 S 1 30 100 m 10 1 h 1 10 m 10 1 h 1 10 30 100 1 - 10 h 1 d 10 30 100 h 1 10 0.1m -101 day 1 10 S 1 1 d 10 m 10 1 h 1 10 h 1 10 1 - 10 days 10 1 10 1 h 1 10 1 d 10 10 S 1 30 100 1 - 10 h m 30 100 10 1 10 S 1 h 1 10 Cycler beginning with pulse 30 100 3 - 30 days 10 m Supply terminals Output indication 1 10 S 1 30 100 0.1 - 1 day m 10 1 10 S 1 Un Rough time setting-PULSE Fine time setting-PULSE m 10 1 10 S 1 Rough time setting-PAUSE m 10 1 h 1 10 30 100 m 10 1 10 S 1 1 10 1 d 10 30 100 t1 t2 LED Terminal for fun Ou TIME 2 CRM-2H Un h 1 10 10 S 1 1 d 10 30 100 m 10 1 10 1 h 1 10 1 d 10 30 100 3 - 30 days h 1 10 1 d 10 10 S 1 1 - 10 min m m 10 1 h 1 10 10 S 1 Rough time setting-PAUSE 1 10 30 CRM-91H S 100 CRM-93H 1 1 - 10 days 15-18 m 10 - 100 days10 1 d 10 TIME 1 U 1 d 10 30 100 TIME 1 15-18 LED Fine time setting-PULSE 1 d 10 10 S 1 1 d 10 30 100 Fine time setting-PAUSE 30 100 h 1 10 U 1 d 10 Rough time setting-PULSE 1 d 10 10 S 1 10 1 h 1 10 Supply indication m 30 100 h 1 10 Su CRM-2H 0.1 - 1 min 1 d 10 Terminal for function selection Supply indication m h 1 10 Cycler beginning with pause Description 0.1 - 1 h 1 d 10 10 S 1 1 - 10 s 1 d 10 10 S 1 m 30 100 m 100 1 Functions 1 - 10 min 1 d 10 10 S 1 30 100 10 1 100 h 1 10 0.1 - 1 s m 1 16A / AC1 4000 VA / AC1, 384 W /DC 30 A / <3 s 250 V AC1 / 24 V DC 500 mW multifunction red LED 3x107 0,7x105 max. 150 ms -20...+55 °C -30...+70 °C 4 kV (supply-output) any DIN rail EN 60715 IP 40 from frontal panel III 2 2,5 mm2 h 1 10 m d 10 mm2 1 d 1 90x17,6x64 1 10 10 10 30 61812-1, 30 EN EN 61010-1 S 0.1 - 1 min Time ranges 10 S 1 AC/DC 12-240 V (AC 50-60 Hz) AC 0,7-3 VA / DC 0,5 - 1,7 W green LED 0.1 s-100 days rotary switch and potentiometer 5% mechanical setting 0,2% set value stability 0,01% / °C at 20 °C 1 1 - 10 s 1 d 10 10 S 1 100 1 0.1 - 1 s Cycler beginning with pause 10 1 10 S 1 1 10 1 d 10 30 100 TIME 2 Fine time setting-PAUSE 30 100 0.1 - 1 h m Output contact 10 1 10 S 1 h 1 10 Dimensions 1 d 10 30 100 CRM-2H 10 - 100 days 1-module design 1-MODULE DESIGN 353 DATA m Cycler beginning with pulse 2 A1-A2 t EVE Delay ON star/delta CRM-2T Connection Technical data CRM-2T 1 A1-A2 AC/DC 12-240 V (AC 50-60 Hz) AC 0,7-3VA/DC 0,5-1,7 W -15% - +10% green LED t1: 0.1 s - 100 days Number of functions Supply Universal supply Consumption Supply voltage tolerance Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient Output Number of contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Reset time Controlling Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards start up of motor ( - ) start of a motor (Motor) S1 S3 auxiliary supply S2 A1 CRM-2T rotary switch and potentiometer 5%-mechanical setting 0,2%-set value stability 0,01% / °C at 20 °C 25 26 28 15 16 18 (motor) S1 2 x changeover (AgNi) 16 A / AC1 4000 VA / AC1, 384 W / DC 30A/<3s max. 250 V AC1 / 24 V DC 500 mW multifunction red LED 3x107 0.7x105 max. 150 ms. 16 A1 A2 1 d 10 30 100 10 1 10 S1 h 1 10 m 10 1 10 S1 30 100 DATA 1 - 10 hrs 354 h 1 10 1 d 10 30 100 m 10 1 10 S1 1 - 10 s 1 d 10 25 U t1 15-18 -20...+55 °C -30...+70 °C 4 kV any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 61812-1, EN 61010-1 0.1 - 1 s m 28 Delay ON star/delta t2 25-28 Description Supply terminals Output indication multifunction LED A2 A1 Supply indication U 15-18 25-28 LED Rough time setting t1 Fine time setting t1 m 10 1 10 S1 h 1 10 h 1 10 30 100 m 10 1 10 S1 0.1 - 1 min 1 d 10 30 100 0.1 - 1 day m 10 1 10 S1 h 1 10 1 d 10 30 100 1 - 10 days h 1 10 1 d 10 30 100 24-480V m 10 1 10 S1 1 - 10 min m 10 1 10 S1 h 1 10 1 d 10 30 100 3 - 30 days t2 LED Fine time setting t2 1 d 10 t1 230 V Time ranges h 1 10 26 S2 Functions 15 10 1 10 S1 18 15 28 25 m A2 h 1 10 1 d 10 30 100 0.1 - 1 h m 10 1 10 S1 h 1 10 1 d 10 30 100 10 - 100 days 18 Output contact Output contact S3 EVE Staircase switch CRM-4 Connection Technical data Function Supply Supply voltage Consumption Supply voltage tolerance Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient Output Changeover contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Control. voltage Consumption of input Load between S-A2 Glow-tubes Control. terminals Impulse length Reset time Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards delay OFF A1-A2 AC-230 V/50-60 Hz AC max. 12 VA/1.8 W - 15%; + 10% green LED 0,5 - 10 min potentiometer 10% mechanical setting 5% set value stability 0,05% / °C at 20 °C 1 16 A / AC1 4000 VA / AC1, 384 W /DC 30 A / <3 s 250 V AC1 / 24 V DC 500 mW red LED 3x107 0,7x105 AC 230 V AC 0,53 VA yes yes, max. 20 pcs. (at 1 mA) A1-S min. 25 ms/max. unlimited max. 150ms -20...+55 °C -30...+70 °C 4 kV (supply - output) any DIN rail EN 60715 IP 40 from frontal panel III 2 2,5 mm2 90x17, 6x64 mm EN 60669-2-3, EN 61010-1 3-wire connection 4- wire connection L L N N A1 S A2 A1 S A2 max. 20mA 250V AC1 16A/4000VA 250V AC1 16A/4000VA 15 16 18 15 16 18 Description Supply terminals Controlling contact Supply indication CRM-4 Output indication Un ON Function setting AUTO CRM-91H CRM-93H OFF t [min] 0.5 Time setting 10 Output contact switch Dimensions CRM-4 MR-41 355 DATA 1-module 1-MODULEdesign DESIGN EVE Programmable staircase switch CRM-42 Connection Technical data Functions Supply Supply voltage Consumption Supply voltage tolerance Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient Output Number of contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Reset time Controlling Control Voltage Input consumption Glow tubes Control terminals Impulse length Reset time Operating temperature Storage temperature Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards CRM-42 delay OFF responsive to control contact switch on A1-A2 AC 230 V50-60Hz AC max. 12VA / 1.8 W -15% - +10% green LED 0.5 - 10 min. potentiometer 5%-mechanical setting 5%-set value stability 0,05% / °C at 20 °C 1, (AgSnO2), switching potential A1 16 A / AC1 4000 VA / AC1, 384W / DC 30A / < 3s. max. 250 V AC1 / 24 V DC 500 mW red LED 3x107 0.7x105 max. 150 ms. 3-wire connection 4-wire connection Functions funkc. ON Function ON red LED Function AUTO red LED AC 230 V A0.53 VA yes, max. 100 pcs. (at 1mA) A1-S ali A2-S min 50ms. / max.unlimited max. 150 ms. -20...+55 °C -30...+70 °C any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 60669-2-3, EN 61010-1 Function PROG red LED Description Supply terminals Control terminal S Supply indication Output indication Function settings Time setting DATA Supply terminals 356 Output contacts
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement