Operating Instructions
IP-Netzwerktechnik
Pos: 2 /#Neustruktur#/Online-Dokumentation (+KNX)/Titelblätter/Sonstige Bereiche/Titelblatt - 8186-31 @ 38\mod_1386240204434_15.docx @ 300980 @ @ 1
8186/31
WLAN access point, flush-mounted
Software version 1.0.0.3
=== Ende der Liste für Textmarke Cover ===
Operating Instructions
IP-Netzwerktechnik
Pos: 4 /#Neustruktur#/Online-Dokumentation (+KNX)/Inhaltsverzeichnis (--> Für alle Dokumente <--)/Inhaltsverzeichnis @ 19\mod_1320649044386_15.docx @ 109653 @ @ 1
1 Safety ....................................................................................................................................................................... 4
2 Intended use ............................................................................................................................................................ 4
3
Environment ............................................................................................................................................................. 4
4 Technical data and settings ..................................................................................................................................... 5
4.1
4.2
Technical data ......................................................................................................................................... 5
Factory settings ....................................................................................................................................... 6
5 Information about licenses ....................................................................................................................................... 7
6
Setup and function ................................................................................................................................................... 8
6.1
General description ................................................................................................................................. 8
6.2
Types of functions ................................................................................................................................... 8
6.2.1
Single mode access point ....................................................................................................................... 8
6.2.2
Access point for extending an installation around WLAN ........................................................................ 9
6.2.3
Operation with several access points .................................................................................................... 10
6.2.4
Increase in the range of WLAN (with WDS) .......................................................................................... 11
6.2.5
Increase in the range of WLAN (without WDS) ..................................................................................... 13
6.2.6
Operation with several access points as separate WLAN networks ..................................................... 15
6.3
Range of transmitting power ................................................................................................................. 17
7
Installation and electrical connection ..................................................................................................................... 18
7.1
Requirements for the electrician ........................................................................................................... 18
7.2
7.3
Mounting ............................................................................................................................................... 19
Electrical connection ............................................................................................................................. 19
7.3.1
Connecting mains power ....................................................................................................................... 19
7.3.2
Connecting the network cable ............................................................................................................... 20
8 Commissioning ...................................................................................................................................................... 21
8.1
8.2
Initial connection ................................................................................................................................... 21
Configuration ......................................................................................................................................... 22
8.2.1
General ................................................................................................................................................. 22
8.2.2
Logon .................................................................................................................................................... 23
8.2.3
Password setting ................................................................................................................................... 23
8.3
Configuration – System – General ........................................................................................................ 24
8.3.1
System settings ..................................................................................................................................... 24
8.3.2
General system settings ........................................................................................................................ 24
8.4
System/Status configuration ................................................................................................................. 24
8.4.1
System language .................................................................................................................................. 25
8.5
Status configuration .............................................................................................................................. 26
8.5.1
Status information ................................................................................................................................. 26
8.6
Network configuration ........................................................................................................................... 27
8.6.1
Network IP settings ............................................................................................................................... 27
8.6.2
Network - IP settings - Settings ............................................................................................................. 28
8.7
WLAN network ...................................................................................................................................... 29
8.7.1
Network - WLAN settings ...................................................................................................................... 31
8.7.2
Network – WLAN settings – Device configuration - General settings .................................................... 31
8.7.3
Network – WLAN settings – Interface configuration - General settings ................................................. 32
8.7.4
Network – WLAN settings – Device configuration - General settings .................................................... 32
8.7.5
Network – WLAN settings – Device configuration - Extended settings ................................................. 33
8.7.6
Interface configuration – WLAN encryption ........................................................................................... 34
8.7.7
Network diagnostics .............................................................................................................................. 34
8.8
Configuration – System – Backups/Updates ......................................................................................... 35
8.8.1
System – Backup/Software-Update ...................................................................................................... 35
8.8.1.1
Backup/Restore .................................................................................................................................... 36
8.8.1.2
Installing new Firmware ........................................................................................................................ 36
8.8.2
Reboot .................................................................................................................................................. 37
8.8.3
Log off ................................................................................................................................................... 37
8.9
Configuration – Expert information ........................................................................................................ 37
8.9.1
Expert diagram ...................................................................................................................................... 37
Operating Instructions | 1473-1-7965 — 2 —
Operating Instructions
IP-Netzwerktechnik
8.9.1.1
LAN1 ..................................................................................................................................................... 37
8.9.1.2
WLAN .................................................................................................................................................... 37
9
Operation ............................................................................................................................................................... 38
9.1
Controlling the flush-mounted WLAN access point via UDP ................................................................. 38
9.2
9.3
Meaning of the LEDs ............................................................................................................................. 39
Reset functions ..................................................................................................................................... 39
9.3.1
Reset to factory settings ........................................................................................................................ 39
9.3.2
Full reset ............................................................................................................................................... 40
10 Fault rectification .................................................................................................................................................... 41
11 Glossary ................................................................................................................................................................. 42
=== Ende der Liste für Textmarke TOC ===
Operating Instructions | 1473-1-7965 — 3 —
Operating Instructions
IP-Netzwerktechnik
Pos: 6 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.docx @ 103357 @ 1 @ 1
1 Safety
Pos: 7 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 8 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bestimmungsgemäßer Gebrauch @ 18\mod_1302763321316_15.docx @ 103483 @ 1 @ 1
Safety
Pos: 9 /#Neustruktur#/Online-Dokumentation (+KNX)/Bestimmungsgemäßer Gebrauch/Sonstige Bereiche/Bestimmungsgemaesser Gebrauch - 8186-31 @ 32\mod_1355394040338_15.docx @ 258814 @ @ 1
This device has three operating modes.
It can be used either as access point for wireless communicating devices or as repeater to increase the transmission range in the WLAN network.
In addition, it can be connected as WLAN adapter via Ethernet to devices which do not have their own WLAN connection.
To set up the device requires an external device, e.g. a laptop.
The device must only be installed in dry indoor rooms.
Pos: 10.1 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/U - Z/Umwelt @ 18\mod_1302614158967_15.docx @ 103383 @ 1 @ 1
3 Environment
Pos: 10.2 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Hinweis Elektrogeräte @ 18\mod_1302763973434_15.docx @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste.
– The device contains valuable raw materials which can be recycled. Therefore, dispose of the device at the appropriate collecting depot.
Pos: 10.3 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Entsorgung Elektrogeräte @ 20\mod_1325760695972_15.docx @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies.
The products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance.
(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos: 11 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 4 —
Operating Instructions
IP-Netzwerktechnik
Pos: 12 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Technische Daten und Einstellungen @ 33\mod_1360750040379_15.docx @ 277375 @ 1 @ 1
4 Technical data and settings
Pos: 13 /#Neustruktur#/Online-Dokumentation (+KNX)/Technische Daten/Sonstige Bereiche/Technische Daten - 8186-31 -- BJE @ 38\mod_1386234045722_15.docx @ 300754 @ 22 @ 1
General
Types of functions:
Mechanical characteristics
Dimensions (L x W x H):
Technical data and settings
Access point, Access point (WDS/Repeater), Client (WDS), Client (Relayd)
80 x 80 x 50 mm
For mounting in commercially available deep flush-mounted, surface-mounted and hollow-wall sockets.
Protection type:
Temperature range during operation:
Connections:
Electrical characteristics
Power supply:
Power consumption:
WLAN characteristics
Radio range:
Radio data rates:
Radio standard:
Security and encryption:
IP 20
-5 … 45°C
RJ 45 (10 / 100 Mbit/s)
Screw contacts
The data rate for all connections is 10 / 100 Mbit/s
100 ... 240 V AC, 50 ... 60 Hz
≤ 1.8 W
2.4 GHz
Maximum 150 Mbit/s
IEEE 802.11 b / g / n
WEP, WPA, WPA2
Operating Instructions | 1473-1-7965 — 5 —
Operating Instructions
IP-Netzwerktechnik
Technical data and settings
System/Administration:
Condition at delivery
Password admin
System/System:
Hostname BJE-WLAN surface mounted
UDP port
Network/LAN/Settings:
None
Own settings
IPv4 address
IPv4 netmask
IPv4 gateway
DNS Server
192.168.55.1
255.255.0.0
None
None
Network/WLAN/Settings:
The WLAN network is activated Yes
Channel Auto
Transmitting power: 100 %
ESSID BJE WLAN surface-mounted
Hide ESSID
HT mode
Network/WLAN/WLAN encryption:
No
Network/Extended settings:
Mode Auto
20 MHz
Mode
Cipher Auto
Key PleaseChange
Network/Diagnostics:
Ping None
Notes
Pos: 15 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 6 —
Operating Instructions
IP-Netzwerktechnik
Pos: 16 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/G - L/Lizenzhinweise @ 38\mod_1386234540127_15.docx @ 300883 @ 1 @ 1
Information about licenses
Pos: 17 /#Neustruktur#/Online-Dokumentation (+KNX)/Linzenzhinweise/Lizenzhinweise - 8186-31 -- BJE @ 38\mod_1386234659526_15.docx @ 300899 @ @ 1
Parts of the firmware are subject to the GNU General Public License.
License Information
This product includes software of third-party suppliers subject to the terms of licence of the GNU General Public
License. You may change or distribute this free software subject to the terms of the GNU General Public License.
Availability of the source code
Upon request we will send you the entire source code of the software licenced under the GNU General Public
License - including all scripts, to control the compilation and installation of the drivers. You can also download it from the e-catalogue (www.busch-jaeger-katalog.de).
Pos: 19 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 7 —
Operating Instructions
IP-Netzwerktechnik
Pos: 20 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Aufbau und Funktion @ 11\mod_1279185435352_15.docx @ 83027 @ 2 @ 1
6 Setup and function
Pos: 21 /#Neustruktur#/Online-Dokumentation (+KNX)/Aufbau und Funktion/Sonstige Bereiche/Funktionen - 8186-31 -- BJE @ 38\mod_1386234133531_15.docx @ 300786 @ 122333333 @ 1
Setup and function
The flush-mounted WLAN access point offers an excellent alternative for meeting the demands made on modern infrastructures according to DIN 18015-2 and RAL-RG 678, without having to go without the convenient use of modern, mobile technology such as tablet PCs or laptops and without limiting the transmission data rates.
Additionally, the flush-mounted WLAN access point functions like a normal data socket with an RJ45 output for a conventional data terminal device (data rate up to 100 Mbit/s). The power is supplied direct via 230 V at the rear of the device.
The flush-mounted WLAN access point can be connected to the internal data network via a classic network cable.
The transmission range of the WLAN can be adapted and limited to the conditions of the room. This creates highperformance radio cells in the room, which ensure a maximum radio band width within the room while operating at minimal power consumption and radiation.
Due to the minimum requirement for energy and resultant minimum radio emission, demarcation problems under individual access points and overcoupling of WLAN areas and reduction of data rates are largely avoided.
6.2
6.2.1
Types of functions
Single mode access point
Internet
Router
WLAN access point, FM
Fig. 1:
Internet coupling of terminal devices in the house via WLAN and RJ45 socket
• Interface to the LAN/Internet
Ip 192.168.x.x
Channel 1-13
Operating Instructions | 1473-1-7965 — 8 —
Operating Instructions
IP-Netzwerktechnik
6.2.2 Access point for extending an installation around WLAN
Splitter WLAN access point, FM
Router
Internet
Setup and function
Fig. 2:
Internet coupling of terminal devices via WLAN for use in an existing installation with patch cable.
Ip 192.168.x.x
Channel 1-13
Operating Instructions | 1473-1-7965 — 9 —
Operating Instructions
IP-Netzwerktechnik
6.2.3 Operation with several access points
WLAN access point, FM
Router Switch
Internet
1)
WLAN access point, FM
2)
to further
WLAN access points, FM
Fig. 3:
Operation of several flush-mounted WLAN access points via a switch
• Interface to the LAN/Internet
(1)
Ip 192.168.x.x
Channel 1-13
(2)
Ip 192.168.x.x
Encryption Free selection or roaming
Channel 1-13
Setup and function
Operating Instructions | 1473-1-7965 — 10 —
Operating Instructions
IP-Netzwerktechnik
6.2.4 Increase in the range of WLAN (with WDS)
WLAN access point, FM
Base station (ESSID)
WLAN access point, FM
(BSSID)
Setup and function
Internet
WDR
Fernsehen
12:59
Router
Fig. 4:
Connection of two network segments via WLAN
• Increase in the range of WLAN-capable devices
• Interface to the LAN/Internet
Base station:
Mode Access point (WDS/Repeater)
Ip 192.168.x.x
Channel 1-13
Client: Network interface 1
SSID From the base station
Ip 192.168.x.y
Encryption From the base station
Channel From the base station
Network Interface 2
SSID Free selection or roaming
Ip Automatic
Encryption Free selection or roaming
Channel Automatic
WDR
Fernsehen
12:59
Operating Instructions | 1473-1-7965 — 11 —
Operating Instructions
IP-Netzwerktechnik
Setup and function
• The base station and client must have the same SSID.
• The IP address must be located in the same area, e.g. 192.168.0.x.
• The encryption must be the same.
• The MAC address of the base station must be entered in the client in field BSSID.
Note
Both devices must be either a flush-mounted WLAN access point, or support the WDS standard.
Operating Instructions | 1473-1-7965 — 12 —
Operating Instructions
IP-Netzwerktechnik
6.2.5 Increase in the range of WLAN (without WDS)
Router
(ESSID)
1)
WLAN access point, FM
Client (ESSID and BSSID)
Internet
(BSSID)
Setup and function
2)
WDR
Fernsehen
12:59
Fig. 5:
Coupling of terminal devices to a WLAN router
• Increase in the range of WLAN-capable devices
• Interface to the LAN/Internet
1) Router:
Ip 192.168.x.x
Channel 1-13
2) Client: Network interface 1
SSID From the base station
Ip 192.168.x.y
Encryption From the base station
Channel From the base station
Network Interface 2
SSID Free selection or roaming
Ip 192.168.x.y
Encryption Free selection or roaming
Channel Automatic
Operating Instructions | 1473-1-7965 — 13 —
Operating Instructions
IP-Netzwerktechnik
Setup and function
• The base station and client must have the same SSID.
• The IP address must be located in the same area, e.g. 192.168.0.x.
• The encryption must be the same.
• The MAC address of the base station must be entered in the client in field BSSID.
Note
This type of function can be used for different devices or when the WDS standard is not supported by the router.
Operating Instructions | 1473-1-7965 — 14 —
Operating Instructions
IP-Netzwerktechnik
6.2.6 Operation with several access points as separate WLAN networks
Setup and function
Room 3
WLAN access point, FM
Access point
(ESSID 2)
Room 2
WLAN access point, FM
Client (ESSID 1)
≈
Room 1
Fig. 6:
Internet
Router
WLAN access point, FM
Base station
(ESSID 1)
Operating Instructions | 1473-1-7965 — 15 —
Operating Instructions
IP-Netzwerktechnik
Inter-room use of the Internet via WLAN
• Interface to the LAN/Internet
• The same SSID for client and base station (room 1 and 2)
• Other SSID for room 3
• The same encryption for all rooms
• The same area for IP address for client and base station (room 1 and 2)
Room 3:
Only access point is possible Mode
Room 2:
Mode
Room 1:
Mode
Client (WDS) with virtual access point (see also chapter 6.2.4)
Access point (WDS)
Ip 192.168.x.x
Channel 1-13
Setup and function
Operating Instructions | 1473-1-7965 — 16 —
Operating Instructions
IP-Netzwerktechnik
Setup and function
6.3 Range of transmitting power
The range of transmitting power is, among others, dependent on the buildings infrastructure. Adjust the location for the flush-mounted access point to the spatial conditions.
As an example for concrete walls, the graphics show the received power in dependence of the transmitting power and the distance to the flush-mounted WLAN access point.
49 % Sendeleistung 100 % Sendeleistung vorne (im Raum) vorne (im Raum)
Meter Meter hinten (in der Wand)
Fig. 7:
Legend
> –70 dBm
Reception possible
–60 to –70 dBm
Good to medium reception
0 to –60 dBm
Very good to excellent reception
Pos: 23 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 hinten (in der Wand)
Operating Instructions | 1473-1-7965 — 17 —
Operating Instructions
IP-Netzwerktechnik
Installation and electrical connection
Pos: 24 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/M - O/Montage und elektrischer Anschluss @ 23\mod_1336477157864_15.docx @ 209033 @ 1 @ 1
7 Installation and electrical connection
Pos: 25 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Niederspannungs- und 230 V-Leitungen @ 23\mod_1336558868201_15.docx @ 209164 @ @ 1
Warning
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
– Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!
Pos: 26 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Fachkenntnisse @ 23\mod_1336559183027_15.docx @ 209179 @ 2 @ 1
7.1 Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
• Incorrect installation endangers your life and that of the user of the electrical system.
• Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
• Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth and short-circuit;
5. Cover or barricade adjacent live parts.
• Use suitable personal protective clothing.
• Use only suitable tools and measuring devices.
• Check the supply network type (TN system, IT system, TT system) to secure the following power supply conditions (classic connection to ground, protective earthing, necessary additional measures, etc.).
Pos: 27 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 18 —
Operating Instructions
IP-Netzwerktechnik
Installation and electrical connection
Pos: 28 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 2 @ 1
7.2 Mounting
Pos: 29 /#Neustruktur#/Online-Dokumentation (+KNX)/Montage/alle Geräte/Montage - UP-, AP- und Hohlwanddosen @ 36\mod_1364194901475_15.docx @ 289292 @ @ 1
The device must only be installed in commercially available deep flush-mounted and surface-mounted wall boxes.
Pos: 30 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/A - F/Elektrischer Anschluss @ 21\mod_1328177051724_15.docx @ 138042 @ 2 @ 1
Pos: 31 /#Neustruktur#/Online-Dokumentation (+KNX)/Anschluss/Sonstige Bereiche/Anschluss - 8186-31 -- BJE @ 36\mod_1364195245401_15.docx @ 289308 @ 23 @ 1
7.3.1 Connecting mains power
Warning
Electric voltage!
Risk of death due to electrical voltage.
First disconnect the mains power before starting any installation work!
Caution
Work on the supply system must only be performed by authorised and qualified electricians!
Connecting the mains power.
• To avoid influencing the network, disconnect the power supply of active components as well as data transmission devices (PC, etc) from those of other consumers (e.g. radio).
• Use line circuit breakers or protectors and, if necessary, independent overvoltage protection (C-arrester).
Fig. 8: Connecting the mains power
* Line circuit breakers or protectors.
Operating Instructions | 1473-1-7965 — 19 —
Operating Instructions
IP-Netzwerktechnik
7.3.2 Connecting the network cable
1. Pull the cable into the flush-mounted wall box from the top.
- Use only device connecting boxes!
2. Shorten the cable so that it projects 90 mm into the box.
3. Strip approx. 80 mm of the cable.
4. Insert the flush-mounted WLAN access point into the box.
5. Pull off the 5-pole screw terminal box.
– Attach the wires according to the colour code.
Installation and electrical connection
Fig. 9: Screw terminal box
Terminals
6
Screen
Orange
3 White
2
1 green
White
Terminal
Assignment
Colour code
Fig. 10: Colour code
Observe the following points:
- Maintain the pairs screen and the twist of the pairs as long as possible.
– Twist the entire screen.
– If necessary, use a 1 mm wire end sleeve.
- Adhere to the assignment in the patch bay and on the box.
6. Attach the terminal block to the screw terminal.
6 3 2 1
7. Check the installation by means of the LEDs (see chapter "Meaning of the LEDs" on page 39) and install the cover.
The device is now ready for operation with the factory settings.
Pos: 33 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 20 —
Operating Instructions
IP-Netzwerktechnik
Pos: 34 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/G - L/Inbetriebnahme @ 11\mod_1279185496977_15.docx @ 83035 @ 2 @ 1
8 Commissioning
Pos: 35 /#Neustruktur#/Online-Dokumentation (+KNX)/Inbetriebnahme/Sonstige Bereiche/Inbetriebnahme - 8186-31 -- BJE @ 38\mod_1386234277190_15.docx @ 300818 @ 2 @ 1
Commissioning
We recommend that you establish the initial connection to the flush-mounted WLAN access point via the RJ45 socket.
• Connection via the RJ45 socket
To establish the connection via the RJ45 socket, connect your PC to the flush-mounted WLAN access point via a network cable.
Make the following TCP/IP settings on the network adapter of the configuration PC (or tablet computers or
Smartphones):
TCP/IP-Einstellungen vor:
– Use the static IP address, e.g. 192.168.55.x, here x must be between 2 and 255.
The flush-mounted WLAN access point can now be reached with a Web browser via address http://192.168.55.1.
To establish the connection via WLAN, select the network with the SSID "BJE WLAN AP". The WPA2 key is
"PleaseChange"; we recommend changing this as soon as possible (see chapter "Interface configuration – WLAN encryption" on page 34).
Make the following TCP/IP settings on the network adapter of the configuration PC (or tablet computers or
Smartphones):
– Use the static IP address, e.g. 192.168.55.x, here x must be between 2 and 255.
The flush-mounted WLAN access point can now be reached with a Web browser via address http://192.168.55.1.
• Configuration via backward LAN interface
If you wish to configure the flush-mounted WLAN access point via the backward LAN interface, the the subnet mask 255.255.0.0 must be set on the router and on the configuration PC.
The flush-mounted WLAN access point can now be reached in your network via address http://192.168.55.1.
Pos: 37 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 21 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
Pos: 38 /#Neustruktur#/Online-Dokumentation (+KNX)/Inbetriebnahme/Sonstige Bereiche/Konfiguration - 8186-31xxx -- BJE @ 38\mod_1386236885061_15.docx @ 300915 @ 22333332323233233333323443323444 @ 1
8.2 Configuration
8.2.1 General
You can configure the flush-mounted WLAN access point via the Web interface and adjust it to your requirements.
Aside from the change of password (see chapter "Password setting" on page 23), also the key in the interface configuration of the WLAN network (see chapter "Network – WLAN settings – Device configuration - General settings" on page 31) should be changed.
Additionally, you should carry out an adjustment to your network and enter the gateway and the DNS server of your router for access to the Internet (see chapter "Network IP settings" on page 27.
Note
Please note that before exiting an application page the changed settings must be saved via button
"Save & apply". Otherwise the changes will not be taken over by the flush-mounted WLAN access point.
After making changes to the settings of the IP address, to the SSID or the WLAN encryption, the connection between the PC and the flush-mounted WLAN access point may be cut and must be reestablished by the PC.
Operating Instructions | 1473-1-7965 — 22 —
Operating Instructions
IP-Netzwerktechnik
8.2.2 Logon
Commissioning
Fig. 11:
Enter the password ("admin" at the point of delivery) and log yourself in.
Fig. 12:
Via menu "System/Administration" you reach the password setting of the flush-mounted WLAN access point.
Raise the access protection by setting an individual password. You can make the password visible by clicking the green arrows.
Confirm the password and save it under "Save and apply".
Operating Instructions | 1473-1-7965 — 23 —
Operating Instructions
IP-Netzwerktechnik
8.3 Configuration – System – General
Commissioning
The system settings apply to all operating modes and can be changed in menu "System".
To recognize the flush-mounted WLAN access point in your network, enter an individual, clear name under
"Hostname" ("BJE-WLAN-AP“ at the point of delivery). The name must start with a letter and must not contain spaces. Invalid entries are marked in red. The changes are taken over with "Save and apply".
A restart must be carried out after the hostname has been changed. Click "Reboot" and in the window that opens click "Perform reboot".
The restart takes approximately one minute.
Fig. 13:
Operating Instructions | 1473-1-7965 — 24 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
Fig. 14:
The control interface can be displayed in German or English.
The settings are taken over with "Save & apply".
Operating Instructions | 1473-1-7965 — 25 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
Fig. 15:
Under "Status", the current system values and the devices that are connect to the flush-mounted WLAN access point are displayed. This makes information about the channel and logged-in stations, for example, available for the configuration. If several stations are logged in, the flush-mounted WLAN access point automatically selects the one with the strongest signal. To ensure safe data transmission the received power should not drop below
20%.
Aside from the access point modell, also the Firmware version can be read off here.
Operating Instructions | 1473-1-7965 — 26 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
The operating mode and additional aspects of configuration are set in register "Network" under "IP-Configuration" and WLAN".
You can select between the three operating modes Access point (state at delivery), Access point (WDS/Repeater) and Client (WDS) (see chapter "Types of functions" on page 8).
8.6.1 Network IP settings
Fig. 16:
In this menu you receive the status information about the LAN settings of your flush-mounted WLAN access point.
Displayed are running time, MAC address, sending/receiving rate and the IP address. The icons in the left of the field have the following meaning:
Interface: network cable
Interface: front connection
Interface: radio control
Operating Instructions | 1473-1-7965 — 27 —
Operating Instructions
IP-Netzwerktechnik
8.6.2 Network - IP settings - Settings
Commissioning
Fig. 17:
Aside from the status information (see chapter "Network IP settings" on page 27), here you can select the protocol (static address or DHCP client), change the IP address and network mask of your flush-mounted WLAN access point, and enter the gateway address and DNS server of your router. By clicking the icon (1), you can add further DNS servers.
Operating Instructions | 1473-1-7965 — 28 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
Fig. 18:
In the WLAN status area you get an overview about the WLAN settings of your flush-mounted WLAN access point. Displayed are radio standard, channel, bit rate, SSID, mode, BSSD, encryption, signal strength in percent, logged-in stations with SSID, MAC address, IP address, signal and noise.
Via button "Scan" (1) an overview of adjacent networks is displayed. If there are several networks, a different channel may have to be chosen.
Via button "Add" and "Delete" (2) additional network interfaces can be set up or removed.
Two network interfaces, for example, are required in the types of functions to increase the WLAN transmission range (see chapter "Increase in the range of WLAN (with WDS)" on page 11 and chapter "Increase in the range of
WLAN (without WDS)" on page 13).
The settings for the relayd function / repeater mode are described in chapter "Relayd function / Repeater mode" on page 32.
Operating Instructions | 1473-1-7965 — 29 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
Fig. 19:
Operating Instructions | 1473-1-7965 — 30 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
8.7.1
8.7.2
Network - WLAN settings
For WLAN settings a distinction is made between device configuration and interface configuration.
Network – WLAN settings – Device configuration - General settings
Fig. 20:
The following settings are possible aside from the status display:
- You can deactivate the WLAN if it not required, to prevent radiation and to save energy. The other two interfaces remain available. You can also switchover via UDP (see chapter "Controlling the flush-mounted
WLAN access point via UDP" on page 38).
• Channel
- The frequency range of adjacent channels superimpose on each other. That is why the channel should be selected in such a way that the frequencies of other radio devices in the vicinity do not overlap (e.g. radio microwave devices in the area of channel 9 and 10). In Germany, 13 channels are permitted, in the USA, for example, only 11. In order not to restrict the selection of devices, we recommend the use of only channels 1 to 11.
– By changing the transmitting power the transmission range of the flush-mounted WLAN access point can be adapted. It should be kept as small as possible in the application range.
Operating Instructions | 1473-1-7965 — 31 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
8.7.3 Network – WLAN settings – Interface configuration - General settings
The settings that are possible in the interface configuration are network-specific:
• ESSID
- Network name with which the flush-mounted WLAN access point is to be connected
• Mode
– Four modes are available for selection:
The operating mode access point, and access point (WDS/Repeater) (see chapter "Types of functions" on page 8)
- Prevents unauthorized devices from seeing your network
The entries are taken over with "Save & apply".
8.7.4 Network – WLAN settings – Device configuration - General settings
Relayd function / Repeater mode
The relayd function is the basis for the repeater function. Here an available, possibly weak WLAN signal is picked up, boosted and re-transmitted as access point on the mounting position of the flush-mounted WLAN access point. This, for example, allows WLAN connections on an available router to be 'extended' and/or made more operationally reliable. Please note that the maximum data rates in the types of functions with repeater function are fundamentally halved with each additional repeat. This is due to the general physical principles of the WLAN transmission and not to any special characteristic of the flush-mounted WLAN access point.
Internet
Router
WLAN access point, FM
WLAN access point, FM
1 x repeated (50 %)
2 x repeated (25 %) possible, not recommendable
Fig. 21:
The types of functions as repeater and access point require appropriate configuration in the flush-mounted WLAN access point.
Since this involves two different type of WLAN functions, two network interfaces need to be set up (see chapter
"WLAN network" on page 29).
The first network interface is configured as "Client (Relayd)". Here the IP address of the Relayd client must lie within the identical address range of the router (or the amplifying device).
The second network interface is parameterized as access point.
Via this network interface during WLAN operation the connection of mobile data transmission units is made, or also additional repeaters that were set up identically in previous processes.
Operating Instructions | 1473-1-7965 — 32 —
Operating Instructions
IP-Netzwerktechnik
8.7.5 Network – WLAN settings – Device configuration - Extended settings
Commissioning
Fig. 22:
Further settings can be made under the device and interface configuration.
• Mode
At the point of delivery the devices can log themselves in according to standard IEEE-802.11-b/g/n. If you wish to limit the access, you can set special radio standards
• HT mode (only for mode 802.11g+n)
In n-Standard, HT 20/40 can be selected. Test the band width with the best result.
Operating Instructions | 1473-1-7965 — 33 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
8.7.6 Interface configuration – WLAN encryption
The WLAN encryption protects the network against attacks from unauthorized users.
• Encryption
The mode set at the point of delivery is the safest; however, it is not supported by some older devices (avoid
WEP!)
• Cipher
Encryption procedure at state of delivery is "auto"
• Key
With the assigning of the key you only allow authorized users access to your network.
Ensure that you change the key!
When selecting the key, observe the same criteria as for selecting the password; however, for the encryption procedure such as WPA and WPA2 for WLAN, the password for security reasons should be at least 20 characters long.
The settings made can now be confirmed and taken over with "Save & apply".
Fig. 23:
With this tool you can test the network and the Internet connections. Enter an Internet address (can be internal or external) and click "Ping". You will then receive information whether the data were sent and the distant end has replied.
Operating Instructions | 1473-1-7965 — 34 —
Operating Instructions
IP-Netzwerktechnik
8.8
8.8.1
Configuration – System – Backups/Updates
System – Backup/Software-Update
Commissioning
Fig. 24:
As backup you can store your individual settings on a PC or you can carry out a reset to factory settings. Also the new Firmware can be installed.
See also chapter "Backup/Restore" on page 36.
See also chapter "Installing new Firmware" on page 36.
Operating Instructions | 1473-1-7965 — 35 —
Operating Instructions
IP-Netzwerktechnik
Commissioning
8.8.1.1 Backup/Restore
For the backup, select a folder on your PC in which you save the current settings. Click "Generate archive". Click
"Upload archive" to restore the status at the point of delivery. If, for example, you wish to install several flushmounted WLAN access points with identical configuration, you can save the settings of a device as backup and load them into additional devices.
New Firmware can be downloaded from our electronic catalogue (www.busch-jaeger-katalog.de). Proceed as follows::
1. Save the file on your PC.
2. If you wish to keep your current settings, confirm this.
3. Select the stored file.
4. Click "Flash image".
Operating Instructions | 1473-1-7965 — 36 —
Operating Instructions
IP-Netzwerktechnik
8.8.2 Reboot
Commissioning
Fig. 25:
With a restart you reset the system or take over the settings you made.
With "Logout" you exit the control interface of the flush-mounted WLAN access point. However, first you must save the settings made. To make further changes, you must log on again with your password.
8.9 Configuration – Expert information
This menu makes detailed information available about the current data transmissions in the LAN and WLAN area, for use as an analysis tool.
8.9.1.1 LAN1
With this diagram you can check whether a LAN connection exists and the data rates that are transmitted in and out within a period of 3 minutes.
8.9.1.2 WLAN
The WLAN diagram provides information about the quality of transmission with regard to signal, noise and the data rate.
Pos: 40 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 37 —
Operating Instructions
IP-Netzwerktechnik
Operation
Pos: 41 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bedienung @ 11\mod_1279185541649_15.docx @ 83043 @ 2 @ 1
9 Operation
Pos: 42 /#Neustruktur#/Online-Dokumentation (+KNX)/Bedienung/Sonstige Bereiche/Bedienung - 8186-31 -- BJE @ 38\mod_1386234334359_15.docx @ 300850 @ 22233 @ 1
9.1 Controlling the flush-mounted WLAN access point via UDP
The WLAN interface of the device can be activated and deactivated via UDP command. Activate the UDP function by entering the desired port under menu "System". No port is set at the point of delivery.
Then confirm the entry by clicking button "Save & apply".
Restart!
To take over the UDP ports entered, a restart of the flush-mounted WLAN access point is absolutely necessary. Click "Reboot" and in the window that opens click "Perform reboot".
- The restart takes approximately one minute.
– The UDP function is then available.
UDP commands
Commands Meaning
WLAN ON Activating the WLAN interface
WLAN OFF Deactivating the WLAN interface
WLAN ? Enquiry of status
Observe capitalization and spaces during the entry.
The flush-mounted WLAN access point confirms a sent UDP command with a reply of the current status.
Operating Instructions | 1473-1-7965 — 38 —
Operating Instructions
IP-Netzwerktechnik
Operation
9.2 Meaning of the LEDs
For a detailed fault analysis and for commissioning, also the status of the LEDs that can be seen on the upper module of the flush-mounted WLAN access point when the cover is removed, can be used. They indicate the activity at the respective ports - screw terminal and UAE socket.
No. Function
1 Link/Act
External Ethernet Port (screw terminal)
2 Link/Act
Local Ethernet Port (UAE socket)
1
2
Fig. 26:
Detail X
Fig. 27:
9.3.1 Reset to factory settings
• Create a bridge during operation for at least 5 to a maximum of 30 seconds (illustration, Detail X)
• The system starts with the factory settings.
Operating Instructions | 1473-1-7965 — 39 —
Operating Instructions
IP-Netzwerktechnik
Operation
If you do not have access to the flush-mounted WLAN access point, you can reset the device fully. After this a firmware must be installed in the flush-mounted WLAN access point.
1. De-energize the flush-mounted WLAN access point.
2. Create a bridge (illustration, Detail X)
3. Reactivate the power supply.
4. Wait 5 seconds.
5
Connect a PC to the flush-mounted WLAN access point via the RJ45 socket.
6
Make the following TCP/IP setting on the network adapter of the PC:
–
–
-
Use the static IP address: 192.168.1.2
Select "Windows - Start - Execute", and there enter "cmd" and confirm with "OK".
Enter "tftp -i 192.168.1.1 put <File name>", replace the <File name> with the file name and path of the current Firmware file (see chapter "Installing new Firmware" on page 36). New Firmware can be downloaded from our electronic catalogue (www.busch-jaeger-katalog.de).
The system sends a feedback signal about the successful data transmission. After a restart the flush-mounted
WLAN access point is then again available with the factory settings.
Meaning of the entry:
C:\ tftp
-i
192.168.1.1
Change to the root directory
Start TFTP client (available in the operating system)
Binary data transmitted
Address of the TFTP server in the flush-mounted WLAN access point
Pos: 44 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 40 —
Operating Instructions
IP-Netzwerktechnik
Pos: 45 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Störungsbeseitigung @ 18\mod_1308568208399_15.docx @ 107037 @ 2 @ 1
Fault rectification
Pos: 46 /#Neustruktur#/Online-Dokumentation (+KNX)/Störungsbeseitigung/Sonstige Bereiche/Stoerungsbeseitigung - 8186-31 @ 38\mod_1386238116606_15.docx @ 300947 @ @ 1
Cause Action
LEDs do not light up
The flush-mounted WLAN access point has no supply voltage. Switch on the supply voltage.
No connection to the WLAN base station
The flush-mounted WLAN access point is outside the range of the base station.
The WLAN function of your flush-mounted WLAN access point has been deactivated.
A different WLAN radio network causes interference.
The encryption of your flush-mounted WLAN access point is set on
"WEP" or is set on "Unencrypted".
The ESSID is set on "hidden".
Reduce the distance between the devices.
Activate the WLAN function.
Set a different channel or set the channel on "Auto".
Set the encryption on WPA/WPA2 in the user interface.
A different encryption procedure has been set on the flushmounted WLAN access point than on the PC.
No WLAN connection to the PC
The WLAN adapter of the PC is not ready.
The ESSID must be set on "visible" for the connection with WEP.
Set the ESSID on "visible". After the connection has been established, the ESSID can be set back on "hidden".
Set the same encryption procedure on the PC that is set on
WLAN access point.
The PC is outside the range of the flush-mounted WLAN access point.
A different encryption procedure has been set on the flushmounted WLAN access point than on the PC.
Check whether the WLAN adapter has been activated; on some devices it must be activated with a switch.
Reduce the distance between the PC and the flush-mounted
WLAN access point.
Set the same encryption procedure on the PC that is set on
WLAN access point.
No access to the devices in the network possible
A firewall is operating on the devices.
Wrong address range / wrong network mask
Allow the firewall access to the network.
Check whether the addresses have been set correctly.
The flush-mounted WLAN access point cannot be located under the IP address
The DHCP client has been activated. Try to locate the device via the WLAN function.
The plain text display for password and key does not function
You are using Internet Explorer 9. Go to the compatibility view and remove all activations under
Extras/Settings.
The diagram is not displayed.
You are using Internet Explorer 7 or 8.
You are using Internet Explorer 9.
Install an SVG plug-in (e.g. from Adobe at http://www.adobe.com/devnet/svg/adobe-svg-viewer-downloadarea.html).
Go to the compatibility view and remove all activations under
Extras/Settings.
Pos: 47 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
Operating Instructions | 1473-1-7965 — 41 —
Operating Instructions
IP-Netzwerktechnik
Pos: 48 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/G - L/Glossar @ 32\mod_1358157269639_15.docx @ 263499 @ 2 @ 1
11 Glossary
Pos: 49 /#Neustruktur#/Online-Dokumentation (+KNX)/Glossar/Sonstige Bereiche/Glossar - 8186-31 @ 38\mod_1386238187254_15.docx @ 300963 @ @ 1
Access point AP
Adapter
Advanced Encryption Standard
Basic Service Set
Basic Service Set Identifier
Cipher
Client
DNS Server
Domain Name System
Extended Service Set
Extended Service Set Identifier
High Throughput
Hostname
Independent Basic Service Set
IPv4 address
IPv4 gateway
IPv4 netmask
Channel
Local Area Network
Glossary
IBSS
AES
BSS
BSSID
DNS
ESS
ESSID
HT mode
LAN
Base station, interface for wireless communication, terminal devices are logged via WLAN into the access point which is connected to the network via cable, comparable with bridges or switches, layer 2 based
Connects a cabled communication device with an AP via WLAN
Freely available encryption algorithm with 128, 192 or 256 bit key length and 128 bit block size
The result of synchronization of relevant parameters with several devices
Corresponds either to the MAC address of the AP or is randomly generated and clearly describes each BSS
Operating mode in which texts that are longer than the block cipher length can be encrypted (e.g. AES)
Connects a cabled communication device with an AP via WLAN, also termed repeater and WLAN adapter
Computer (Server) that carries out name resolution
Forms the name resolution, i.e. conversion of a hostname into the relevant
IP address
Coupling several WLAN radio cells into a larger one
Connecting of several APs to a network requires the same SSID, which is in this case called ESSID
Larger band width in HT-40 mode and with it higher speeds are possible.
Transmission range is reduced, speed advantage only partly realistic
(IEEE-802.11-n devices are required, provided the connection is optimal).
Name of AP
BSS is a closed network without connection to another network
Fourth version of the Internet Protocol, 32.bit address in four blocks of decimal style with 8 bits each, one value range from 0-255 and separated by a point (xxx.xxx.xxx.xxx)
Links networks of different protocols, specifies the path to the Internet
Division between the network part and address part of the IP address, computers are in the same network if the address part is the same (the bits of the netmask that are equal to "1")
The frequency range available in the 2.4 GHz range is for better utilization divided into 14 channels, the first 13 being available in Europe.
Local network with maximum extension of 500 m, mainly in the home and up to small companies
Operating Instructions | 1473-1-7965 — 42 —
Operating Instructions
IP-Netzwerktechnik
Mode
Port
Protocol
Repeater
Roaming
Key / password
Transmitting power
Service Set Identifier
Temporal Key Integrity Protocol
User Datagram Protocol
Encryption
Wi-Fi Protected Access
Wired Equivalent Privacy
Wireless Distribution System
SSID
TKIP
UDP
WPA
WPA2
WEP
WDS
Wireless Local Area Network
=== Ende der Liste für Textmarke Content ===
WLAN
Glossary
Setup and function on page 8
Part of a network address to assign data packets between client and server. With UDP the port number of the service that is to receive the data is also sent
Software agreement for data transmission
Signal amplifier that increases the transmission range
Taking the WLAN connection along from one AP to the next
Access protection
Delivered power of the AP mostly indicated in dBm
Freely selectable name of a WLAN up to 32 character long, setting in the
AP and all connected clients
Security protocol in the WLAN or other radio networks is based on the
IEEE-802.11 standard
Simple, wireless network protocol for transmitting data. Port are used for assigning the data to the correct application.
Serves for the security of data transmission
WLAN encryption algorithm
Successor of WPA and based on AES according to WLAN standards IEEE
802.11 a,b,g,n
WLAN encryption algorithm
Procedure for addressing data frames, setup of a radio network with several APs, WDS both with a WLAN interface (Single-Radio-WDS, connection to the AP and client), as well as with several Dual-Radio-WDS, one interface to the AP and another one to the client, implemented on the
AP, differentiation in bridging ( 2 WLAN bridges connected) and repeating mode (several APs connected via WDS).
Like WLAN, but wireless
Operating Instructions | 1473-1-7965 — 43 —
Operating Instructions
IP-Netzwerktechnik
Pos: 51 /#Neustruktur#/Online-Dokumentation (+KNX)/Rückseiten (--> Für alle Dokumente <--)/Rückseite - BJE-Variante @ 32\mod_1357201421897_15.docx @ 262132 @ @ 1
A member of the ABB Group
Busch-Jaeger Elektro GmbH
PO box
58505 Lüdenscheid
Freisenbergstraße 2
58513 Lüdenscheid
Germany
www.BUSCH-JAEGER.de
Central sales service:
Phone: +49 (0) 2351 956-1600
Fax: +49 (0) 2351 956-1700
=== Ende der Liste für Textmarke Backcover ===
Notice
We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice.
The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.
We reserve all rights to this document and the topics and illustrations contained therein. The document and its contents, or extracts thereof, must not be reproduced, transmitted or reused by third parties without prior written consent by ABB.
Copyright© 2013 Busch-Jaeger Elektro GmbH
All rights reserved
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 Safety
- 4 Intended use
- 4 Environment
- 5 Technical data and settings
- 5 Technical data
- 6 Factory settings
- 7 Information about licenses
- 8 Setup and function
- 8 General description
- 8 Types of functions
- 8 Single mode access point
- 9 Access point for extending an installation around WLAN
- 10 Operation with several access points
- 11 Increase in the range of WLAN (with WDS)
- 13 Increase in the range of WLAN (without WDS)
- 15 Operation with several access points as separate WLAN networks
- 17 Range of transmitting power
- 18 Installation and electrical connection
- 18 Requirements for the electrician
- 19 Mounting
- 19 Electrical connection
- 19 Connecting mains power
- 20 Connecting the network cable
- 21 Commissioning
- 21 Initial connection
- 22 Configuration
- 22 General
- 23 Logon
- 23 Password setting
- 24 Configuration – System – General
- 24 System settings
- 24 General system settings
- 24 System/Status configuration
- 25 System language
- 26 Status configuration
- 26 Status information
- 27 Network configuration
- 27 Network IP settings
- 28 Network - IP settings - Settings
- 29 WLAN network
- 31 Network - WLAN settings
- 31 Network – WLAN settings – Device configuration - General settings
- 32 Network – WLAN settings – Interface configuration - General settings
- 32 Network – WLAN settings – Device configuration - General settings
- 33 Network – WLAN settings – Device configuration - Extended settings
- 34 Interface configuration – WLAN encryption
- 34 Network diagnostics
- 35 Configuration – System – Backups/Updates
- 35 System – Backup/Software-Update
- 36 Backup/Restore
- 36 Installing new Firmware
- 37 Reboot
- 37 Log off
- 37 Configuration – Expert information
- 37 Expert diagram