Electrolux EDW7505HPS - Semi-Integrated Dishwasher With 5 Wash Cycles Service manual


Add to my manuals
88 Pages

advertisement

Electrolux EDW7505HPS - Semi-Integrated Dishwasher With 5 Wash Cycles Service manual | Manualzz

Electrolux

EFS - Dishwashing Systems Platform

Electrolux Professional

SERVICE MANUAL

CONTENTS:

EDITION:

3.__

TANK

BOILER

3.__

TANK

BOILER

3.__

TANK

BOILER

This document contains the instruction to change parameter settings of electronic board by means of user interface.

06.2005

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.1/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

INDEX

1. KEYBOARDS

1.1 HOODTYPE Style

1.2 UNDERCOUNTER Style

2. MANUAL ACTIVATION OF DETERGENT AND RINSE AID DISPENSERS

2.1 Detergent Dispenser Activation

2.2 Rinse Aid Dispenser Activation

3. RINSE PUMP MANUAL ACTIVATION

4. DETERGENT AND RINSE AID DOSAGE

5

5

5

3

3

4

5

6

GEn

General Parameters

5. COUNTERS

6

8

Cnt

Counters 8

6. TEMPERATURE SETTING

FAC

Factory Parameters

7. CYCLE SETTING

CYCLE DIAGRAM

CY1

Cycle 1 Parameters

CY2

Cycle 2 Parameters

CY3

Cycle 3 Parameters drn

Drain/Cleaning Cycle Parameters

8. OTHER PARAMETERS dPA

Dishwashing Parameters ron

Read Only Parameters

HCP

Communication and HACCP Parameters

CFG

Configuration Parameters dbG

Parameters for automatic hood type dishwashers

9. SPECIAL FEATURES

9.1 RESIN REGENERATION CYCLE

9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE

9.3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION

9.4 dISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER

10. MAIN BOARD CONFIGURATION

10.1 CODEÆProg. TABLE

10.2 PROGRAMMING SHEETS

11. DEFAULT VALUES

12. USER INTERFACE AND MAIN BOARD CONNECTORS

12.1 MAIN MALFUNCTIONS NOT DUE TO THE MAIN BOARD

12.2 CONNECTORS LAYOUT

13. ALARM MESSAGES AND TROUBLESHOOTING

9

8

11

13

13

13

13

14

14

14

14

15

16

17

17

17

17

18

19

19

24

72

75

75

75

82

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.2/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. KEYBOARDS

1.1. HOOD TYPE Style

dEt dEt rAi rAi

---

---

Fig. 1.2

Rinse Aid Dispenser

Manual Activation.

Fig. 1.3

Rinse Pump

Manual Activation

(used to EMPTY BOILER)

Fig. 1.1

Detergent dispenser

Manual Activation.

SETTING MODES:

To enter into one setting mode (Fig.1.4, Fig.1.5) the appliance should be in stand-by: switch on the appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not simultaneously pressure of the two keys.

GEn

Enter into General Parameters

(Hold down buttons for at least five seconds).

Fig. 1.4

GEn

888

Fig. 1.6

Next Parameter Family OR

Increase Parameter Value

(In setting mode only)

888

Fig. 1.5

Enter into Factory Parameters

FAC

(Hold down buttons for at least five seconds).

888

FAC

Fig. 1.7

Decrease Parameter Value

(In setting mode only)

888

888

Fig. 1.8

Confirm Value and go to next Parameter

(In setting mode only)

888

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.3/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1.2. UNDERCOUNTER Style

dEt rAi

TANK

BOILER

TANK

BOILER

---

TANK

BOILER

Fig.1.1

Detergent dispenser

Manual Activation

Fig.1.2

Rinse Aid Dispenser

Manual Activation

Fig.1.3

Rinse Pump

Manual Activation

(used to EMPTY BOILER)

SETTING MODES:

To enter into one setting mode (Fig.1.4, Fig.1.5) the appliance should be in stand-by: switch on the appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not simultaneously pressure of the two keys.

GEn

TANK

BOILER

FAC

TANK

BOILER

888

TANK

BOILER

888

TANK

BOILER

888

TANK

BOILER

Fig. 1.4

Enter into General Parameters

(Hold down buttons for at least five seconds).

Fig. 1.5

Enter into Factory Parameters

(Hold down buttons for at least five seconds).

Fig.1.6

Next Parameter Family

OR

Increase Parameter Value

(in setting mode only)

Fig.1.7

Decrease Parameter Value

(In setting mode only)

Fig.1.8

Confirm Value and go to next Parameter

(in setting mode only)

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.4/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

2. MANUAL ACTIVATION OF DETERGENT AND RINSE AID

DISPENSERS

When replacing detergents may be necessary activate the dispensers to fill hoses.

2.1. Detergent Dispenser Activation

dEt

Switch on the dishwasher.

Press and hold down CYCLE_2 and CYCLE INFINITE keys, after two 'beep' the detergent dispenser starts work for 20 sec.

2.2. Rinse Aid Dispenser Activation

rAi

Switch on the dishwasher.

Press and hold down CYCLE_1 and CYCLE INFINITE keys, after two 'beep' the rinse aid dispenser starts work for 40 sec.

3. RINSE PUMP MANUAL ACTIVATION

Use this function to empty the boiler (if the dishwasher is not to be used for a long time, for maintenance operation: ex. before replacing main board).

---

Switch on the dishwasher.

Close the door and press and hold down DRAIN and CYCLE INFINITE keys. A buzzer signal indicates the rinse pump activation and the display shows three blinking lines. Three beeps indicate the cycle end.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.5/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

4. DETERGENT AND RINSE AID DOSAGE

In this paragraph is explained how to set the working time for the detergent and rinse aid dispensers.

For each dispenser there are two parameters: the initial time and the time during cycle execution.

GEn

General

Unit Min Max

Factory

Default

dIn

Initial Detergent Dosage (during filling tank) rIn

Initial Rinse Aid Dosage (starts when tank filled) dEt

Detergent Dosage During Cycle Execution (during wash phase) rAi

Rinse Aid Dosage During Cycle Execution (when refilling boiler)

[s]

[s]

[s]

[s]

0

0

0

0

240

180

182(*)

62 (*)

90

10

8

4

How change the duration:

• Switch OFF and switch ON the dishwasher;

• Enter into the USER SETTING mode by pressing and hold down ON/OFF and CYCLE_1 keys for at least five seconds the display shows

GEn

(Fig.3.1);

• Press CYCLE_INFINITE. The display shows alternatively the symbol dIn

and the duration in seconds (Fig.3.2 and 3.3);

NOTE: If User Interface v.3.00 tank led is on if value correspond to factory default (Default 1, HOOD TYPE).

• Use CYCLE_1 key to decrease the duration and CYCLE_2 key to increase (Fig.3.3);

• After settled the duration press CYCLE_INFINITE key to store value. The display shows the next parameter (Fig.3.4) and the corresponding value (Fig.3.5);

• In the same way is possible to change the other duration; when finished switch OFF and switch ON.

GEn

Fig. 3.1

Enter into User Mode

(press for 5 sec). dIn

Fig. 3.2

Initial detergent dosage dEt

Fig. 3.6

Cycle detergent dosage

ª

90

DEFAULT

©

Fig. 3.3

Change duration.

(Tank LED indicates default).

8

DEFAULT

ª ©

Fig. 3.7

Change time activation

(Tank LED indicates default) rIn

Fig. 3.4

Initial rinse aid dosage rAi

Fig. 3.8

Cycle rinse aid dosage

ª

Fig. 3.5

Change duration

ª

24

©

7

©

Fig. 3.9

Change time activation

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.6/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

(*) Note for external dispensers:

• If

DEt=181 the detergent dispenser works when WASHING PUMP is being activated; at the same time voltage is supplied between connectors L1

7

–L1

9

(main terminal box);

• If

dEt=182

the same time voltage is supplied between connectors L1

7

–L1

9

(main terminal box);

• If

rAi= 61 the rinse aid dispenser works when LOADING EV is being activated to re-fill boiler level; at the same time voltage is supplied between connectors L1

8

–L1

9

(main terminal box);

• If

rAi= 62 the rinse aid dispenser works when WASHING PUMP is being activated; at the same time voltage is supplied between connectors L1

8

–L1

9

(main terminal box);

- For electrical connections refer to electric diagram -

Example

Suppose there is connected an external detergent dispenser with a probe into the tank. A typical setting could be:

DIn= 0 the dispenser is not activated during filling tank;

DEt=181 the dispenser is supplied during washing phase and the probe automatically dose the right detergent amount.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.7/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

5. COUNTERS

This Parameter Family collects cycle counters and water consumption counters.

For water consumption counters a flow meter must be installed. See

PPL

(calibration parameter) into dPA

section (§ Other Parameters).

Cnt

Counters

Unit Min Max

Factory

Default

CYC

Cycles performed counter.

CYC

symbol and two numbers blink consecutively. The cycle number is obtained by joining the two numbers. Ex.

CYC

10

042

means

10042 cycles executed. cYc

Cycle counter (resettable).

This counter is similar to

CYC

but is resettable by user (see rSt

parameter below). nnc

Water Consumption. [present up to software version 3.12]

Counts m

3

of water consumption.

L

Water Consumption. [present up to software version 3.12]

Counts litres

of water consumption.

The total consumption is given by adding nnc

[m

3

] and

L

[l] values.

Lit

Water Consumption: resettable counter. [present up to software version 3.12]

Counts the litres of water and is resettable by user (see rSt

parameter below). rSt

Reset resettable counters: cYc

and

Lit

To reset put 1 this parameter, switch off and then on again: cYc

and

Lit will show zero. Note that cYc

is used to count cycles for

CAll

message

(see next parameter, nCY

). nCY

Store thousand of cycles after that

CAll

message appears on display.

Ex. If this parameter is settled to 20,

CAll

message appears when cYc reach 20.000 cycles. drn

Drain/Cleaning cycles performed.

Similar to

CYC

but counts Cleaning Cycles. rCY

Numbers of cycles that can be made after a regeneration cycle (only for dishwashers with non-continuous water softener) [See paragraph 9.1 resin regeneration cycle.].

NRE

Regeneration cycle counter (only for water softener dishwasher)

[See paragraph 9.1 resin regeneration cycle / paragraph 9.4 Dishwashers with incorporated continuous water softener].

-

-

[m

3

]

[l]

[l]

-

-

-

-

-

20

GEn

Fig.4.1

CYC

Fig. 4.4

CYCLES

USER setting mode

(press for 5s)

DOC. NO. 5956.446.06

GEn

Fig.4.2

Next Family

010

Fig. 4.5

Thousand.

Cnt

Fig. 4.3

Counters Fam.:

ENTER

042

Fig. 4.6

Units.

©Copyright 2005 by

Electrolux Professional cYc

Fig. 4.7

Next counter.

P.8/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

6. TEMPERATURE SETTING

In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and tank.

FAC

Factory

bt°C

Boiler Temperature: THRESHOLD.

When boiler temperature reaches this value, heaters switch off. btH

Boiler Temperature HISTERESIS, (represent dead band).

Heater switch on if boiler temperature is below:

bt°C - btH bHi

Boiler Temperature: HIGH LIMIT.

When boiler temperature reaches this value

C 2 alarm appears.

Put 0 to disable

C 2

alarm. bLo

Boiler Temperature: LOW LIMIT.

During boiler warm-up, temperature must increase at least bLo

°C otherwise

E 3

warning appears.

Put 0 to disable

E 3

warning. bFL

Boiler Filling Timeout.

If filling time is longer than bFL

,

A 1

alarm appears.

Put 0 to disable

A 1

alarm. bAJ

Boiler Temperature Adjust. bP

Boiler Priority (enable boiler wait function)

0=disabled

1=enabled bSt

Booster Function

Overheat gap over Boiler Temperature Threshold btd

Boiler temperature negative differential: when the dishwasher is in standby, boiler threshold becomes:

bt°C - btd

(Used to save energy during machine inactivity by keeping boiler water at a lower temperature). tt°C

Tub Temperature: THRESHOLD

When tank temperature reaches this value, heater switch off. ttH

Tub Temperature: HISTERESIS, (represent dead band).

Heater switch on if tank temperature is below:

tt°C - ttH tHi

Tank Temperature: HIGH LIMIT.

When tank temperature reaches this value

C 3 alarm appears.

Put 0 to disable

C 3

alarm. tLo

Tank Temperature: LOW LIMIT.

During tank warm-up, temperature must increase at least bLo

°C otherwise

E 2

warning appears.

Put 0 to disable

E 2

warning. tFL

Tank Filling Timeout.

If filling time is longer than tFL

,

A 1

alarm appears.

Put 0 to disable

A 1

alarm.

[

°C]

[

°C]

[

°C]

[

°C]

[

°C]

[

°C]

Max

Default

45 95 78

[min] 0 42

5

[°C] 0 7

4

[°C] 0 15 2

[°C] 0 20 0

[

°C]

[

°C]

2 10 2

0 98 96

0 10 1

40 85 63

2 30 5

0 95 75

0 10 1

[min] 0 42 20

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.9/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

To modify thresholds do the following:

• Switch OFF and switch ON the dishwasher;

• Enter into the FACTORY SETTING mode by pressing and hold down ON/OFF and CYCLE_2 keys for at least five seconds (Fig.5.1);

• Press CYCLE INFINITE. The display shows alternatively the symbol bt°C

(Fig.5.2) and the corresponding value

76

(Fig.5.3);

• Use CYCLE_1 key to decrease the value and CYCLE_2 key to increase (Fig.4.3);

• Press CYCLE INFITE key to confirm. The display shows the next parameter (Fig.4.4) and the corresponding value (Fig.4.5);

• In the same way is possible to change the other parameters; when finished switch OFF and switch ON.

FAC bt°C 76 btH

Fig. 5.1

Factory setting mode

Fig. 5.2

Boiler temp. threshold

ª ©

Fig. 5.3

Change value & Store

Fig. 5.4

Boiler Temp Hysteresis

2

ª ©

Fig. 5.5

Change value & Store bHi

Fig. 5.6

Tank temp. High limit.

96

ª ©

Fig. 5.7

Change value & Store bLo

At the end the display will show again ‘FAC’ and by pressing CYCLE_2 key (Fig.4.9) is possible to change cycle duration (see next paragraph).

FAC

Fig. 5.9

Factory setting mode

FAC

Fig. 5.10

Next Family

CY1

Fig. 5.11

Cycle 1 Family:

ENTER

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.10/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

7. CYCLE SETTING

In this paragraph is explained how to change cycle phases duration (see Tab.1 next page).

• Switch on the dishwasher;

• Enter into the FACTORY SETTING mode: press and hold down ON/OFF and CYCLE_2 keys for at least 5 seconds (Fig.5.1);

• Press CYCLE_2 key to select CYCLE_1 parameters.

• Press CYCLE_INFINITE. The display shows alternatively the symbol (Fig.5.2) and the corresponding value (Fig.5.3);

• Use CYCLE_1 key to increase the value and CYCLE_2 key to decrease (Fig.5.3);

• Press CYCLE_INFINITE key to confirm. The display shows the next parameter (Fig.5.4) and the corresponding value (Fig.5.5);

• In the same way is possible to change the other parameters;

FAC FAC CY1 Ln1

Fig. 6.1

Factory setting mode.

Fig. 6.2

Select next class.

Fig. 6.3

Cycle 1 Family:

ENTER

Fig. 6.4

Wash duration [min].

0

ª ©

Fig. 6.5

Change value & Store.

Sh1

Fig. 6.6

Wash duration [sec].

35

ª ©

Fig. 6.7

Change value & Store.

After settled all parameters referring Cycle 1, by pressing CYCLE_2 key is possible to change the Cycle 2 parameters (Fig.5.8, 5.9) and so on.

CY1 CY2 Ln2

Fig. 6.8

Cycle 1 Parameters.

Fig. 6.9

Cycle 2 Parameters:

ENTER

CY2

Fig. 6.11

Cycle 2 Parameters: next Family

Fig. 6.10

Wash duration [min].

Cy3 Ln3

ª ©

Fig. 6.13

Wash duration [min].

ENTER

Fig. 6.12

Cycle 3 Parameters:

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.11/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

CYCLE DIAGRAM

CYCLE TYME

Electronic Dishwasher

SERVICE MANUAL

WASH

IPA Ln Sh

PA

PRE RINSE

Pr

RINSE ri

COLD RINSE cr

DRAIN dr

RINSE PAUSE rPA

FINAL

PAUSE

FP

DETERGENT

DEt

RINSE AID

RAi

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.12/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

CY1

Cycle 1 Parameters

Electronic Dishwasher

SERVICE MANUAL

Ln1

Wash Phase Long

Sh1

Wash Phase Short

[min]

[s]

0

1

20

60

0

35

PA1

Pause [s]

Pr1

Pre-rinse Duration [s] 0 30

0

ri1

Rinse Phase Duration cr1

Cold Rinse Phase Duration

[s]

[s]

10

0

45

50

16

0

dr1

Drain [s]

FP1

Final Pause at End of Cycle [s] 0 60

0

CY2

Cycle 2 Parameters

Ln2

Wash Phase Long

Sh2

Wash Phase Short

[min]

[s]

0

1

20

60

0

45

PA2

Pause [s]

Pr2

Pre-rinse Duration ri2

Rinse Phase Duration

[s]

[s]

0

10

30

45

0

16

cr2

Cold Rinse Phase Duration [s] 0 50

0

dr2

Drain [s]

FP2

Final Pause at End of Cycle [s] 0 60

0

CY3

Cycle 3 Parameters

Ln3

Wash Phase Long

Sh3

Wash Phase Short

1

40

PA3

Pause [s]

Pr3

Pre-rinse Duration [s] 0 30

0

ri3

Rinse Phase Duration cr3

Cold Rinse Phase Duration

[min]

[s]

[s]

[s]

0

1

10

0

20

60

45

50

16

0

dr3

Drain [s]

FP3

Final Pause at End of Cycle [s] 0 60

0

bt3

Boiler Temperature Threshold: only for Cycle 3.

This parameter allows having a different rinsing temperature for the [°C] 0 95 0 third cycle. Only values above 45°C are allowed. drn

Drain/Cleaning Cycle Parameters

Idr

Initial Drain Phase Duration

Fdr

Final Drain Phase Duration

DOC. NO. 5956.446.06

[s]

[s]

©Copyright 2005 by

Electrolux Professional

0

0

240

240

40

60

P.13/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

8. OTHER PARAMETERS

dPA

Dishwashing

Electronic Dishwasher

SERVICE MANUAL

IPA

Initial Pause before start washing (for ALL cycles) dLY

Delay for the 2 nd

wash pump (PW only)

Pdr

Active a drain phase at the end of washing phase.

RPA

Duration of pause after rinse cycle (valid for dishwashers with door/hood lock device) [See par. 9.2 Medical line dishwasher with door/hood lock device].

C F

Celsius/Fahrenheit selection

0 = Celsius

1 = Fahrenheit rit

Rinse Temperature Display.

Enable rinse temperature probe (if installed).

0 = during rinse phase the display shows boiler temperature;

[s]

[s]

[s]

0

0

0

10

10

40

0

3

0

[s] 0 60 0

1 = during rinse phase the display shows rinse temperature;

PPL

Pulse Per Litre.

This parameter must be settled in according to flow meter installed.

CdE

Number of wash cycles performable without detergent (only for dishwashers with external detergent level sensor – par. 9.2.1 Detergent

[p/l] 0 255 0 and rinse aid level sensors activation) [LES=1]

1LE

Pressure sensor threshold 1 [present up to software version 2.11].

1HS

Pressure sensor histeresis 1 [present up to software version 2.11].

2LE

Pressure sensor threshold 2 [present up to software version 2.11].

-

-

-

0

0

0

255

255

255

140

50

140

2Hs

Pressure sensor histeresis 2 [present up to software version 2.11]. - 0 255

50

Note:

1LE

,

1HS

,

2LE

,

2HS

parameters emulates a two levels pressure switch, keep in mind that value doesn’t correspond to a physical quantity. ron

Read Only Parameters

rEL

Main Board Firmware Release rLs

Water softener board software version.

CAll

When

CAll

message appears, the parameter value becomes 1.

After maintenance, to clear

CAll

message, insert 0.

C 8

When

C 8

alarm appears, the machine is frozen and this parameter is 1.

After maintenance (see alarm codes document), insert 0 to enable the machine.

F21

This alarm appears in case of malfunctioning in the continuous water softener. To facilitate fault-finding, see par. E "Alarm codes that stop the machine for models with incorporated continuous water softener".

HCP

Communication and HACCP Parameters

- - - -

- - - -

- - - -

- - - -

- - - -

SEr

Serial Device

0 = 8N1

1 = PC connection (DAAS 8E1)

7 = HACCP network (ECAP 8E1+LK485)

(LK485 board is necessary)

9 = Dishwashers with incorporated continuous water softener

16 = HACCP printer (8N1)

32 = MODEM GSM (DAAS 8N1)

33 = MODEM GSM (DAAS 8E1)

48 = Hyper Terminal (8N1)

Adr

Address.

This parameter specifies the address of the appliance into the

‘HACCP_network’.

Works only if ‘HACCP network’ is selected (see above parameter).

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.14/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

Prn

Print parameter table. bt

HACCP ‘Basic’ (printer)

Boiler temperature: high limit. bH

HACCP ‘Basic’ (printer)

Boiler temperature: gap below high limit. tt

HACCP ‘Basic’ (printer)

Tank temperature: high limit. tH

HACCP ‘Basic’ (printer)

Tank temperature: gap below high limit.

- 0 1

1

[°C] 45 95 90

[°C] 0 20 10

[°C] 35 75 68

[°C] 0 20 10

CFG

Configuration

Unit Min Max

Default

tYP

Dishwasher Model:

0 = HOOD TYPE & UNDERCOUNTER

1 = POT WASHER

2 = AUTOMATIC POT WASHER

3 = MEDICAL LINE DISHWASHER WITH LOCK DOOR/HOOD

DEVICE boi

Boiler type:

0 = ATMOSPHERIC BOILER

1 = PRESSURE BOILER

2 = EXTERNAL BOILER doo

Door type:

0 = AUTOMATIC HOOD

1 = MANUAL HOOD

2 = FRONT LOADING

3 = POT WASHER dFL

Default model (see Default tables):

1 = HOOD TYPE

2 = POT WASHER

3 = UNDERCOUNTER trc

Solid State Relay (TRIAC).

0 = not enabled;

1 = SOFT START enabled;

3 = SLOW SOFT START enabled

(works only on boards with Solid State Relay). b_t

Boiler/Tank heating swap:

0 = boiler heaters and tank heater can work simultaneously;

1 = swap enabled: tank heating starts only boiler temperature is reached;

(Note: disabling this function changes the global electrical power of appliance; before enabling this function check available power, supply cable section, fuses in according to User Manual). btF

Tank Filling Mode

Enable filling tank by means of rinsing cycles.

Ex: btF

= 75 means that boiler water is heated at 75°C, then follows a rinse phase and so on until tank is full.

If btF

= 0 the tank is filled by solenoid valve in the traditional way.

LES

Detergent Level Switches

0 = level switches not enabled;

1 = enable detergent level switches;

UI

USER INTERFACE MODEL

8 = ACTIVE function disabled

(up to version 3.11 [up to serial nr.

42100099] set to 0)

9 = hood type, under counter (up to version 3.11 [up to serial nr.

42100099] set to 1)

13 = LS5 with atmospheric boiler(up to version 3.11 [up to serial nr.

42100099] set to 5)

15 = LS5 with pressure boiler (user interface without display); (up to

version 3.11 [up to serial nr. 42100099] set to 7)

See parameter

rEL

(family

ron) to check the software version r installed in the board.

E

Enable “regeneration cycle” key (only for dishwashers with non-continuous water softener) [See paragraph 9.1 resin regeneration cycle].

ALr

ALARMS ENABLE

0 = alarms disabled (to disable also warnings see bLo

and tLo

);

1 = alarms enabled;

If this function is disabled, faults can be detected so display do not shows any alarm code.

- 0 3 0

- 0 2 0

0 3 1

- 0 3 -

- 0 3 0

- 0 1 1

[°C] 0 85 75

- 0 1 0

- 0 15 9

- 0 1 0

- 0 1 1

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.15/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

AAG

Air gap with float level sensor. - dbG

Parameters for automatic hood type dishwashers

0 1

0

t 1

DELAY_K1

Time (during hood lifting) within which S3” must return to the rest position. t 2

HOOD_TOUT

TIMEOUT – max. time allowed for complete hood opening/closing. t 3

DELAY_K1_S3

During hood lowering, firstly S3” must cut in and then after a time t3 .

the bottom limit switch S3. t 4

DELAY_K

Time within which K and K’ must be both closed or both open. t 5

DELAY_S3

Time during hood lifting within which the bottom limit switch must return to the rest position.. t 6

DELAY_S5

Time during hood lowering within which the top limit switch must return to the rest position.

AL_

Displays the last alarm code relative to automatic hood type dishwashers.

Ith

Parameter only valid for hood type models.

Hood lifting motor absorption threshold.

(50 units correspond to a current of approx. 1 ampere). sEN

Parameter for the implementation of new characteristics [present up to software version 3.12].

0.1 s 0.0 s. 20.0 s

0.1 s 0.0 s. 20.0 s

0.1 s 0.0 s. 20.0 s

0.1 s 0.0 s. 20.0 s

0.1 s 0.0 s. 20.0 s

0.1 s 0.0 s. 20.0 s

- - -

15

200

15

10

20

20

-

- 0 250 100

- 0 1

0

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.16/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

9. SPECIAL FEATURES

9.1 RESIN REGENERATION CYCLE

TANK

BOILER

The regeneration cycle is activated by pressing the button shown in the figure, for at least 5 seconds.

For this key to be enabled parameter rE

( in family

CFG

) must be set to 1

.

At this point you can enter the number of wash cycles that can be performed after each regeneration: parameter rCY

in the counters family

Cnt

. If

rCY

is set to zero the counter is disabled, otherwise after the preset number of cycles the message rEG

is displayed to confirm that regeneration is possible (this is an information-only message with no effect on operation of the appliance, so you can continue to use the dishwasher). The message is cleared when the regeneration cycle is terminated.

The number of regeneration cycles performed can be checked by consulting the parameter nrE

in the

Cnt

family of counters.

When there are just 15 cycles remaining before the next regeneration cycle, at the end of the wash cycle the display shows the message

End followed by

15

, at the end of the next wash cycle the display shows

End

and

14

, and so forth, i.e. the display informs the user of the number of wash cycles still available before resin regeneration is required.

Before starting the regeneration cycle remove the siphon spillway.

CAUTION: if the regeneration cycle is accidentally started, it can be switched off by pressing the button shown in the figure, for at least 5 seconds.

The hardness of the water exiting the softener can vary between 3°fH - 10 °fH / 1.7 °dH - 5.6 °dH / 2.1 °cH - 7 °cH.

9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE

The medical line dishwasher with door/hood lock device has a device that prevents door/hood opening for the entire duration of the work cycle.

For the door/hood lock to be active, the parameter tYP

(in the

CFG

family) must be set to

3

.

The dishwasher door/hood is locked at the start of a wash cycle and is released at the end of the final pause after rinse. The wash compartment can be accessed by stopping the work cycle in progress, as the locking device is thus disabled.

A pause at the end of rinse can be set by means of the parameter rPA

(in the dPA

family). This parameter is common to all

3 wash cycles. The rinse water temperature is displayed during this pause. Another final pause in the cycle can be set by setting the parameters

FP1

,

FP2

,

FP3

. During the final pause the display shows the time remaining for completion of the cycle.

The door/hood lock device will be deactivated at the end of the final pause (

FP1

,

FP2

,

FP3

).

For correct performance of the wash cycle the pause at the end of rinse and the final pause must assume the default values

(see Prog 032 – 034 - 035).

9.3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION

By setting the parameter

LES

(in the

CFG

family) to

1

, management of the level sensors located inside the external detergent and rinse aid tanks is enabled. During the rinse phase, when the rinse aid inside the tank has finished, the message rAi 0

appears on the display.

When the detergent inside the tank is finished, the message dEt 0

is displayed and after a number of wash cycles equal to

CdE

(in the dPA

family) the dishwasher inhibits the activation of other wash cycles. Therefore the detergent level in the tank must be restored.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.17/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER

Dishwashers with incorporated continuous water softener have a continuous softener in the water circuit. By means of special resins, this device removes the calcareous substances from the feed water, supplying decalcified water for washing.

To activate the continuous water softener set the parameter

SER

(in the

HCP

family) to the value

9

.

For the continuous softener to work properly the resins must be regenerated periodically, with frequency depending on the hardness of the water and the number of wash cycles carried out. Unlike conventional water softeners, this continuous softener does not require machine stops for regenerating the resins.

To regenerate the resins it is necessary to put kitchen salt in the special container located in the dishwasher.

In particular, the salt container must be filled when the dishwasher is used for the first time and whenever the message

SAL 0

is displayed at the start of a wash cycle. The salt container holds up to 1.5 kg of salt.

IMPORTANT: The message

SAL 0

may appear for several wash cycles even after topping-up the salt, as the salt must circulate in the entire system. Correct operation of the dishwasher is not, however, affected.

The number of regeneration cycles performed can be checked by consulting the parameter nrE

in the

Cnt

family of counters.

The hardness of the water exiting the softener can vary between 3°fH - 10 °fH / 1.7 °dH - 5.6 °dH / 2.1 °cH - 7 °cH.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.18/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

10. MAIN BOARD CONFIGURATION

When receiving an electronic board (spare part) may be necessary to configure it in according to the machine where has to be replaced.

1. With the machine CODE enter into the following table and read the corresponding Prog. number;

2. Follow the instructions reported into the corresponding Prog.XXX sheet (next pages).

3. With the machine CODE find the Layout number in Par. 12.2 – Connectors layout.

10.1. CODEÆProg. TABLE

LS5/3WSDP

LS5/3WSDPD

LB5G

LB5GDP

LS5/1DP60

LS5/1DPAUS

LS6EP

LS6EP/DD

LS6EA/DD

LS6EA/DD/DP

WT38TDE

WT38/M50

LS6EADPWS

LS6EADPWSG

WT38WS

WT38WSG

WT38MEDWS

WT38PM50

WT37LEV/9

WT38M50/4

LS6EA/UK

LS6EA/UKDP

WT4

WT4B

WT4D

WT4DB

WT46

WT4G

WT4DG

WT4WS1

WT4BWS

WT4DWS1

WT4BDWS

WT4D60

LS5/1

LS5/1 DP

LS5/1WS

LS5/1WSDP

LS5/3

LS5/3 DP

LS5/3WS

DOC. NO. 5956.446.06

400007 021 11

LS6EA/60

400008 020 8

400009 021 11

WT 38DD

WT 37

400015 020 8

WT 38

400016 020 8

400017 022 8

WT 37/4.5

WT 38/4.5

400018 022 8

WT 37/UK

400019 024 11

WT38C

400027 012 8

400028 024 11

WT38C60

WT38CUK

400029 012 8

WT 38/UK

400042 021 11

WT37J60

400100 021 11

WT37J50

400102 021 11

LS6AH240U

400103 024 11

WT30H208U

400110 024 11

WT30H240U

400112 020 8

WT30H208DU

400113 020

400114 012

400115 012

8

8

8

WT30H240DU

WT30H208RU

WT30H240RU

LS6H208DU

400117 012 8

400118 022 8

400119 022 8

LS6AH208U

WT 38/60

400124 021 11

WT 38/M60

400125 036 11

WT 38MED

502003 013

502004 013

8

8

LS6H240DU

LS6H208RU

502005 011

502006 011

8

8

LS6H240RU

WT30M208U

502007 032 10

WT30M240U

502008 015

502014 044

502015 044

502016 048

9

8

8

8

WT30M208DU

WT30M240DU

WT30M208RU

WT30M240RU

502017 048

502018 045

8

8

WT30C208DU

WT30C240DU

502019 039

502020 033

9

8

WT38PM60

WT38M60/4

502029 015

502030 011

502031 011

9

8

8

LS6EA

LS6EA/DP

LS6EAH

©Copyright 2005 by

Electrolux Professional

P.19/88

502041 011 8

502110 046 8

502111

046

8

502112

046

8

502117

046

8

502118

046

8

502122

046

8

502125 033 8

502126 033 8

502127 033 8

502217

046

8

502218

046

8

502219

046

8

502312 027 9

502313 031 9

502314 031 9

502315 031 9

502316 031 9

502317 031 9

502318 031 9

502319 027 9

502320 027 9

502321 046 8

502322 015 9

502323 014 8

502325 027 9

502326 027 9

502327 027 9

502328 034 10

502329 034 10

502339 034 10

502341 034 10

502342 034 10

502343 034 10

502344 038 9

502345 038 9

502346 039 9

502347 015 9

502520 011 8

502521 011 8

502523 011 8

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS 10 HD

LS14EA/AU

LS14EA/60

LS 10 UK1

LS 10 UK3

LS 12 INS

LS 12

LS 12 DP

LS 12 60Hz

LS 12 CW

HT 1200 DEK

LS14EA/ASIA

LS14EA/G

WT 60 DP

WT 60

WT 60 CW

LS6MCD

LU7PDP

LU7ADP

WTU40PDP

WTU40ADP

LS 10

LS14EA

LS 10 UK DP

ET12E

LS 10/60Hz

LS 10 CW

LS 10 INS

HT 1200 ins DEK

LS14EA/INS

LS 10 N

LS 10 DP

WT 60 UK DP CW INS

WT 60 INS

WT 60 CW INS

WT 60 AU CW

WT 60 AU N

LS10EA

WT 60/60HZ

WT 60/60HZ CW

WT 60 N

WT 60 N INS

LS 12 HD

LS14EA/DD

WT65E

WT65EB

WT65EI

WT 60 AU DP

LS 12 UK/3 CW

WT 60 UK CW

DOC. NO. 5956.446.06

502524 033

503020 040

503021 041

503023 040

503024 047

504100 002

504101 001

504102 002

504104 003

504105 002

504107 002

504108 002

504109 001

504110 001 4

504111 002 1

504114 002 1

504115 008

504116 004

504117 001

504118 002

504119 002

504120 001

504121 001

504122 001

504125 001

504128 001

504129 001

504131 009

504133 001

504134 001

504135 001

504136 001

504137 001

504138 001

504139 001

504140 004

504141 004

504142 002

504145 001

504146 001

504151 001

504152 001

504153 007

504155 001

504156 001

504157 001

504158 001

504159 004

504161 001

504162 001

8

9

9

9

9

1

4

1

1

1

1

1

1

1

4

4

1

1

1

1

1

1

1

1

4

4

1

1

1

1

1

1

1

1

4

1

1

1

1

1

4

1

4

1

1

1

LS14ADP/G

WT65MED

WT65EJ50

WT65EJ60

LS14AH240U

WT65H208U

WT65H240U

LS 12 ASIACW

WT 60 ASIACW

LS 12 ASIANB

WT60ASIANB

LS14H208DU

LS14AH208U

LS14H240DU

LS14H208RU

LS14H240RU

LS 12 AU

LS 12 UK DP CW

ECOTEMP 12 SW

WT65EBI

WT65EBIA

WT65EIA

WT65E60

WT65EB60

WT 60 U/400

WT 60 U/440

WT65EBIDG

WT65EBASIA

WT65EIM50

WT65EIM60

WT 60 MX 220/60

LS 12 CW INS

WT65H208DU

WT65H240DU

WT65H208RU

WT65H240RU

WT65M208U

WT65M240U

WT65M208DU

WT65M240DU

WT65M208RU

WT65M240RU

LS14EAWS

LS14ADPWSG

LS14EAIWS

WT65EBWS

WT65BIDWSG

WT65EBIWS

WT65MEDWS

LS9P

©Copyright 2005 by

Electrolux Professional

504163 004 1

504164 001 1

504165 001 1

504166 001 4

504167 004 4

504168 004 1

504169 001 1

504170 001 4

504171 006

504172 006

504173 001 4

504174 009 4

504175 006 2

504176 006 2

504177 001 1

504178 001 1

504179 001 4

504180 010 4

504183 001 1

504186 001 1

504187 028 3

504188 028 3

504189 028 3

504190 009 1

504191 009 1

504192 009

504193 009

504194 028 3

504195 028 3

504196 028 3

504197 028 3

504198 028 3

504199 028 3

504200 028 3

504201 028 3

504202 028 3

504203 035 12

504204 035 12

504205 035 12

504206 035 12

504207 035 12

504208 035 12

504209 042 4

504210 042 4

504211 042 4

504212 042 4

504213 042 4

504214 042 4

504215 043 4

505022 019 6

P.20/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

PPW2 M UK

PPW2 60 Hz

PPW2 V

WT830 M

WT830 M UK

WT830 60 Hz

WT850 M

WT850 M UK

WT850 60 Hz

WT850 V

WT830 MH

WT830EA

WT850EA

WT830EAG

WT850EAG

WT830M208U

WT830M240U

WT830H208U

WT830H240U

WT850M208U

WT850M240U

PW1M208U

PW1M240U

PW1MH208U

PW1MH240U

PW2M208U

PW2M240U

LS9P DD

LS9A UK

LS9P60

WT55P

WT55P6

LS9ADG1

WT55ADG1

LS9PAUS

WT55PM50

WT55PM60

PPW1 M

PPW1 M UK

PPW1 60 Hz

PPW1 MH

PPW2 M

FL5

FL5DP

LV5

LV5DP

LV5/3WSDP

FL5/3WSDP

UC5/1DP

UC5/1WSDP

LD5DP

DOC. NO. 5956.446.06

505033 019

505034 018

505035 019

6

6

6

LD5

FL 620EP

ET5EDG

LV6EP

505038 019 6

505039 019 6

505041 018 6

H3300

H2500

505042 018 6

505043 019 6

H3500

ET5EDCW

505044 019 13

LV6EADPWS

505045 019 13

HT1200WS

506010 005 7

506011 005 7

HT1200IWS

FL620ADPWS

506012 005 7

H1310SANA

506013 005 7

H1510SANA

506014 005

506015 005

7

7

LV1200IWS

HT900P

506016 005 7

LV900P

506017 005

LD900

506018 005 7

LU700PDP

506019 005 7

LU700ADP

506020 005 7

PW100 M

506022 005 7

PW200 M

506023 005

506024 005

7

7

PW200 V

PW100 MH

506025 005

LV100M

506026 005 7

LV200M

506215 017 5

HT 1200

506216 017 5

HT 1000

506217 017 5

HT 1000 INS

506218 017 5

506029 037 3

HT 1200 INS

506030 037 3

HT 1200 DP

ET12EIG

506031 037 3

ET12EI

506032 037 3

LV1000

506033 037 3

LV1200INS

506034 037 3

ET12EICWG

506035 037 3

ET12EICW

506036 037 3

FL 620EA

506037 037

506038 037

3

3

FL 620EADP

ET5E

506039 037 3

ET5ED

506042 037 3

690004 020 8

FL 620EA/DD

690005 020 8

FL 620EADP/DD

690006 020 8

LV6EA

690007 020 8

LV6EADP

690008 012

690009 012

8

8

LS10 INS DP

LS 10 INS

690010 021 11

LS 10

690011 024 11

LS 10/fiera

690013 020 8

FL 620EP/DD

©Copyright 2005 by

Electrolux Professional

690014 020 8

698003 013 8

698004 023 8

698006 013 8

698007 029 8

698008 019 6

698009 001 4

698010 016 8

698011 048 8

698012

042 4

698013

042 4

698014 048 8

698016 030 8

698017 010 4

698018

042 4

698022 019 6

698023 019 6

698024 019 6

698033 040 9

698034 047 9

698040 005 7

698041 005 7

698042 005 7

698043 005 7

698044 005 7

698045 005 7

698050 001 4

698051 002 4

698052 002 1

698053 001 4

698055 001 1

698056 026 3

698057 025 1

698059 002 4

698060 001 4

698061 001 3

698062 025 3

698070 046 8

698071 046 8

698076 016 8

698077 016 8

698078 013 8

698079 046 8

698080 046 8

698081 046 8

698082 046 8

S36220 002

S37858 002

S39968 002

S42549 002

P.21/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

HT1200

WT 60 CW INS

HT 1000

WT 60/9

WT 60/9

WT 60/9

WT60 INS

WT60 INS

WT 60 CW

LS 12 HD

HT1200

LS 12 CW INS

WT 60 AU CW

WT 60 INS

WT 60 INS

WT 60 N INS

WT 60/60HZ DP

LS 12 CW INS

WT 60 DP

WT 60/9

WT 60/60HZ DP

WT 60/9 INS

WT 60 U/230

LS 10 INS

LS 10

HT 1000

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 CW

LS 10 UK1

LS 10 CW

LS 12 CW INS

WT 60 CW INS

LS 12 CW INS

WT 60

WT 60

WT 60 AU CW

LS 12 CW

HT 1200

LS 12 UK/3 CW

LS 12 CW

WT 60 CW

LS 12 CW

DOC. NO. 5956.446.06

S43062 002

S43327 002

S475CH 002

S47APN 002

S47CF5 002

S47DU4 002

S47DU7 002

S47DUA 002

S47DUF 002

S47E17 002

S47E2C 002

S47E2H 002

S47E2M 002

S47E2R 002

S47E50 002

S47E6M 002

S46002 001

S46880 001

S4734M 002

S47539 001

S4756O 001

S4756P 001

S475GJ 001

S475GY 001

S476HA 001

S4775E 007

S4777U 001

S477BM 001

S477JR 004

S477M1 001

S477M1 001

S477MB 001

S477QB 001

S477V7 001

S47811 001

S4781D 001

S4781I 001

S4786P 001

S478KF 006

S478LV 001

S478SP 001

S479VE 001

S479Z3 001

S479Z9 001

S47AP80 004

S47APP 001

S47B9I 001

S47BJI 001

S47C1Z 001

S47C6B 001

MODEL

WT 60

LS 12 CW

HT1200

HT1200

ECOTEMP 12

WT 60/9 INS

HT1200

LS 12 INS

WT 60/60HZ

LS 12/fiera

WT 60/60HZ

WT 60 N

LS12 CW

LS 12 INS

LS 12 DP CW

LS 12 CW

LS 12 CW

WT 60 CW

WT 60/9

WT 60/9

WT 60

LS 12 CW

LS 12 CW

WT 60 giappone

WT 60 giappone

WT 60 giappone

WT 60 giappone

LS 12 CW

HT1200

WT 60 giappone

WT 60 giappone

LS 12 CW

WT 60 CW INS

LS6EA

WT 37

LS6EA

FL 620EA

WT830 MH

PPW1 M

WT830 MH

PPW1 MH

WT830 M

PPW1 M UK

WT 60 CW INS

WT 60 CW INS

ECOTEMP 12 SW

ECOTEMP 12 SW

WT 60 CW INS

WT 60

LS 12 CW

S47CCS 001

©Copyright 2005 by

Electrolux Professional

CODE Prog Layout

S47CCY 001

S47CEA 001

S47CEH 001

S47CEI 001

S47CKD 001

D04713 001

S34369 001

S34377 001

S34378 001

S35178 001

S35179 001

S35246 001

S35330 001

S36384 001

S36385 001

S36846 001

S36847 001

S39964 001

S40472 001

S40785 003

S41170 001

S41185 001

S42032 001

S42170 001

S42550 001

S42617 001

S43119 001

S43488 001

S43563 001

S43734 001

S43806 001

S43830 001

S44421 001

S477BL 011

S4784U 011

S4787B 011

S478BN 011

S46881 005

S4758V 005

S476YZ 005

S477IT 005

S479QS 005

S47BKQ 005

S47CPB 001

S47CQS 001

S47CVG 001

S47CVH 001

S47D9Y 001

S47DCA 001

S47DE0 001

P.22/88

MODEL

LS 12 CW

WT 60

WT 60

WT 60

PPW1 MH

PPW1 MH

WT850 M

PPW2 M

PPW2 M

PPW2 M

PPW2 M

WT850 M

PPW2 M

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

CODE Prog Layout

S47DMM 001

S47DSK 001

S47DWC 001

S47DWD 001

S47C37 005

S47DE1 005

S43016 005

S44099 005

S44399 005

S45958 005

S47BW4 005

S47CFG 005

S47CZ1 005

Electronic Dishwasher

SERVICE MANUAL

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.23/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

10.2. PROGRAMMING SHEETS

LS12 – LS14 / WT60 - 65 Prog. 001

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 78

Boiler Temperature Threshold.

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.24/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 78

Boiler Temperature Threshold.

CY1

Cycle 1

Sh1 45

Short Wash Phase [s]

CY2

Cycle 2

Ln2 1

Long Wash Phase [min]

Sh2 40

Short Wash Phase [s]

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.25/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 0

Boiler heaters and tank heater work simultaneously. . btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 65

Boiler Temperature Threshold. bAJ 2

Boiler Temperature Adjust.

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.26/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS12 AU / WT60 - 65 AU Prog. 004

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 0

Automatic Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 78

Boiler Temperature Threshold.

5. Modify the other parameters:

CY1

Cycle 1

FP1 2

Final Pause [s]

CY2

Cycle 2

FP2 2

Final Pause [s]

CY3

Cycle 3

FP3 2

Final Pause [s] dPA

Dishwashing parameters family.

IPA 2

Initial Pause

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.27/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

PW 1 - 2 / WT830 - 850 Prog. 005

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 1

Pot Washer. boi 0

Atmospheric boiler. doo 2

Front loading function. dFL 2

Default values for Pot Washer models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 78

Boiler Temperature Threshold.

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.28/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT60 - 65 USPH Prog. 006

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 78

Boiler Temperature Threshold.

5. Modify the cycle parameters:

CY1

Enter into Cycle 1 parameters family. ri1 25

Rinse Phase Duration [s] dr1 25

Drain [s]

CY2

Enter into Cycle 2 parameters family. ri2 25

Rinse Phase Duration [s] dr2 25

Drain [s]

CY3

Enter into Cycle 3 parameters family. ri3 25

Rinse Phase Duration [s] dr3 25

Drain [s]

6. Select Fahrenheit : dPA

Enter into Dishwashing parameter family.

C F 1

Select Fahrenheit degrees.

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.29/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify the cycle parameters:

CY1

Enter into Cycle 1 parameters family.

Pr1 20

Pre-rinse Duration [s] dr1 36

Drain [s]

CY2

Enter into Cycle 2 parameters family.

Pr2 20

Pre-rinse Duration [s] dr2 36

Drain [s]

CY3

Enter into Cycle 3 parameters family.

Pr3 20

Pre-rinse Duration [s] dr3 36

Drain [s]

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.30/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify the cycle parameters:

CY1

Enter into Cycle 1 parameters family.

Sh1 45

Short Wash Phase [s]

Pr1 20

Pre-rinse Duration [s] dr1 36

Drain [s]

CY2

Enter into Cycle 2 parameters family.

Ln1 1

Long Wash Phase [min]

Sh2 40

Short Wash Phase [s]

Pr2 20

Pre-rinse Duration [s] dr2 36

Drain [s]

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.31/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS12 - 14 / WT60 - 65 ASIA Prog. 009

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 78

Boiler Temperature Threshold. bp 0

Boiler Priority Disabled

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.32/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 0

Automatic Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 90

Boiler Temperature Threshold. bHi 0

Disable boiler high Temperature alarm (

C 2

). bAJ 0

Boiler Temperature Adjust. bSt 0

Booster Function. tHi 85

Tank high Temperature limit.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 2

Long Wash Phase [min]

Sh1 32

Short Wash Phase [s] ri1 35

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 15

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 3

Long Wash Phase [min]

Sh2 32

Short Wash Phase [s] ri2 35

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 15

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 5

Long Wash Phase [min]

Sh3 32

Short Wash Phase [s] ri3 35

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 15

Final Pause [s]

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.33/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

3.

1.

2. dPA

Set other parameters.

IPA 4

Initial Pause [s]

6. Switch OFF and then switch ON the machine.

LS6 6000W ATM Prog. 011

Switch OFF and then switch ON the machine.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.34/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS5WS / WT4WS TRIPHASE Prog. 012

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 13

Select user interface for LS5 (up to version 3.11 set to

5

)

.

rE 1

Regeneration cycle enabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 83

Boiler Temperature Threshold. bAJ 2

Boiler Temperature Adjust. bSt 2

Booster Function.

5. Modify the cycle parameters:

CY3

Cycle 3 parameters family.

Ln3 1

Long Wash Phase [min]

Sh3 40

Short Wash Phase [s]

6. Switch OFF and then switch ON the machine.

7. Modify Detergent dosage:

GEn

Enter into GEn parameter family. dIn 70

Initial Detergent Dosage [s]. rIn 5

Initial Rinse Aid Dosage [s].

8.

Cnt

Counters rCy 20

Number of cycles allowed before regeneration.

9. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.35/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS6 PRESS Prog. 013

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 1

Pressure boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 86

Boiler Temperature Threshold.

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.36/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT38 MED Prog. 014

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 90

Boiler Temperature Threshold. bHi 0

Disable boiler high Temperature alarm (

C 2

). bAJ 0

Boiler Temperature Adjust. bSt 0

Booster function not needed. btd 10

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 65

Tub Temperature Threshold. tHi 85

Tank high Temperature limit.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 4

Long Wash Phase [min]

Sh1 10

Short Wash Phase [s] ri1 35

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 15

Final Pause at End of Cycle

CY2

Cycle 2 parameters family.

Ln2 6

Long Wash Phase [min]

Sh2 10

Short Wash Phase [s] ri2 35

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 15

Final Pause at End of Cycle

CY3

Cycle 3 parameters family.

Ln3 9

Long Wash Phase [min]

Sh3 10

Short Wash Phase [s] ri3 35

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 15

Final Pause at End of Cycle

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.37/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT30 USPH Prog. 015

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 82

Boiler Temperature Threshold. btd 3

During stand-by boiler is kept at lower temperature than Temperature Threshold. bSt 0

Booster Function not necessary. tt°C 66

Tank Temperature Threshold. tHi 80

High limit for tank temperature.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 1

Long Wash Phase [min]

Sh1 22

Short Wash Phase [s] ri1 25

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 4

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 2

Long Wash Phase [min]

Sh2 22

Short Wash Phase [s] ri2 25

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 4

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 4

Long Wash Phase [min]

Sh3 22

Short Wash Phase [s] ri3 25

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 4

Final Pause [s]

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.38/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT30 USPH drn

Drain parameters family.

Idr 30

Initial Drain Phase Duration [s] dPA

Set other parameters.

IPA 5

Initial Pause [s]

C F 1

Fahrenheit.

6. Switch OFF and then switch ON the machine.

Prog. 015

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.39/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

ECOTEMP 5 Prog. 016

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 0

Tank and boiler heaters work simultaneously. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 77

Boiler Temperature Threshold. btd 3

During stand-by boiler is kept at lower temperature than Temperature Threshold.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 1

Long Wash Phase [min]

Sh1 10

Short Wash Phase [s] ri1 25

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 4

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 2

Long Wash Phase [min]

Sh2 22

Short Wash Phase [s] ri2 25

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 4

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 4

Long Wash Phase [min]

Sh3 22

Short Wash Phase [s] ri3 25

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 4

Final Pause [s] drn

Drain parameters family.

Idr 30

Initial Drain Phase Duration [s] dPA

Set other parameters.

IPA 5

Initial Pause [s]

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.40/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT830EA / WT850EA Prog. 017

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 2

Automatic Pot Washer. boi 0

Atmospheric boiler. doo 3

Automatic Pot Washer dFL 2

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 2

Long Wash Phase [min]

Sh1 29

Short Wash Phase [s]

FP1 5

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 5

Long Wash Phase [min]

Sh2 29

Short Wash Phase [s]

FP2 5

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 8

Long Wash Phase [min]

Sh3 29

Short Wash Phase [s]

FP3 5

Final Pause [s]

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.41/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS9 / WT 55 ATM Prog. 018

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 82

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. bSt 1

Booster Function.

5. Modify the cycle parameters:

CY2

Cycle 2 parameters family.

Sh2 55

Short Wash Phase [s]

CY3

Cycle 3 parameters family.

Ln3 4

Long Wash Phase [min] dPA

Set other parameters.

IPA 5

Initial Pause [s]

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.42/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS9 / WT55 PRESS Prog. 019

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 1

Pressure boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 84

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. bSt 1

Booster Function.

5. Modify the cycle parameters:

CY2

Cycle 2 parameters family.

Sh2 55

Short Wash Phase [s]

CY3

Cycle 3 parameters family.

Ln3 4

Long Wash Phase [min]

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.43/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1.

2.

3.

4.

6.

7.

5.

8.

LS5 / WT 4 PRES Prog. 020

Switch OFF and then switch ON the machine.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 1

Pressure boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 15

Select user interface without display (up to version 3.11 set to

7

)

.

rE 0

Regeneration cycle enabled.

ALr 0

ALARMS NOT ENABLED.

Switch OFF and then switch ON the machine.

Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 84

Boiler Temperature Threshold. bAJ 3

Boiler Temperature Adjust. bSt 2

Booster Function.

Modify the cycle parameters:

CY3

Cycle 3 parameters family.

Ln3 1

Long Wash Phase [min]

Sh3 40

Short Wash Phase [s]

Switch OFF and then switch ON the machine.

Modify Detergent dosage:

GEn

Enter into GEn parameter family. dIn 165

Initial Detergent Dosage. rIn 0

Initial Rinse Aid Dosage. dEt 182

Detergent dispenser works when LOAD SOLENOID VALVE in activated. rAi 61

Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.

Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.44/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS5 / WT 4 PRES MONO Prog. 021

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 1

Pressure boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 15

Select user interface without display (up to version 3.11 set to

7

)

.

rE 0

Regeneration cycle disabled.

ALr 0

ALARMS NOT ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 82

Boiler Temperature Threshold. bAJ 3

Boiler Temperature Adjust. bSt 2

Booster Function.

5. Modify the cycle parameters:

CY3

Cycle 3 parameters family.

Ln3 1

Long Wash Phase [min]

Sh3 40

Short Wash Phase [s]

6. Switch OFF and then switch ON the machine.

7. Modify Detergent dosage:

GEn

Enter into GEn parameter family. dIn 165

Initial Detergent Dosage. rIn 0

Initial Rinse Aid Dosage. dEt 182

Detergent dispenser works when LOAD SOLENOID VALVE in activated. rAi 61

Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.

8. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.45/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

3.

4.

8.

6.

7.

5.

1.

2.

Switch OFF and then switch ON the machine.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 15

Select user interface for LS5 (up to version 3.11 set to

7

)

.

rE 0

Regeneration cycle disabled.

ALr 1

ALARMS ENABLED.

Switch OFF and then switch ON the machine.

Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 85

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. bSt 2

Booster Function.

Modify the cycle parameters:

CY3

Cycle 3 parameters family.

Ln3 1

Long Wash Phase [min]

Sh3 40

Short Wash Phase [s]

Switch OFF and then switch ON the machine.

Modify Detergent dosage:

GEn

Enter into GEn parameter family. dIn 70

Initial Detergent Dosage [s]. rIn 5

Initial Rinse Aid Dosage [s].

Switch OFF and then switch ON the machine.

ECOTEMP5 EAG Prog. 023

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.46/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

LS5WS / WT4WS MONO Prog. 024

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 13

Select user interface for LS5 (up to version 3.11 set to

5

)

.

rE 1

Regeneration cycle enabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 83

Boiler Temperature Threshold. bAJ 2

Boiler Temperature Adjust. bSt 2

Booster Function.

5. Modify the cycle parameters:

CY3

Cycle 3 parameters family.

Ln3 1

Long Wash Phase [min]

Sh3 40

Short Wash Phase [s]

6. Switch OFF and then switch ON the machine.

7. Modify Detergent dosage:

8.

GEn

Enter into GEn parameter family. dIn 70

Initial Detergent Dosage [s]. rIn 5

Initial Rinse Aid Dosage [s].

Cnt

Counters rCy 20

Number of cycles allowed before regeneration.

9. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.47/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS12 ECOTEMP (EUROPE) Prog. 025

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 0

Tank and boiler heaters work simultaneously. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

RE 0

Regeneration cycle disabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 82

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust.

5. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.48/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS12 ECOTEMP UK Prog. 026

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

RE 0

Regeneration cycle disabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 82

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

DR1 0

Drain [s]

CY2

Cycle 2 parameters family.

DR2 0

Drain [s]

CY3

Cycle 3 parameters family.

DR3 0

Drain [s] drn

Drain parameters family.

Idr 30

Initial Drain Phase Duration [s] dPA

Set other parameters.

Pdr 30

Drain Phase Duration at the end of washing phase. [s]

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.49/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS6AH Prog. 027

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

RE 0

Regeneration cycle disabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 84

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. btd 3

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 68

Tank Temperature Threshold. ttH 2

HISTERESIS of Tank Temperature.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 1

Long Wash Phase [min]

Sh1 36

Short Wash Phase [s]

FP1 4

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 2

Long Wash Phase [min]

Sh2 36

Short Wash Phase [s]

FP2 4

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 3

Long Wash Phase [min]

Sh3 36

Short Wash Phase [s]

FP3 4

Final Pause [s] dPA

Set other parameters.

C F 1

Fahrenheit.

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.50/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS14AH / WT65H Prog. 028

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

RE 0

Regeneration cycle disabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 84

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. tt°C 68

Tank Temperature Threshold. ttH 2

HISTERESIS of Tank Temperature.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Sh1 37

Short Wash Phase [s]

PA1 3

Pause [s]

FP1 4

Final Pause [s]

CY2

Cycle 2 parameters family.

Sh2 46

Short Wash Phase [s]

FP2 4

Final Pause [s]

CY3

Cycle 3 parameters family.

Sh3 36

Short Wash Phase [s]

FP3 4

Final Pause [s] dPA

Set other parameters.

C F 1

Fahrenheit.

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.51/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1.

2.

3.

H3300 Prog. 029

Switch OFF and then switch ON the machine.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.52/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 90

Boiler Temperature Threshold. bHi 0

Disable boiler high Temperature alarm (

C 2

). bAJ 0

Boiler Temperature Adjust. bSt 0

Booster function not needed. btd 10

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 65

Tub Temperature Threshold. tHi 85

Tank high Temperature limit.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 4

Long Wash Phase [min]

Sh1 10

Short Wash Phase [s] ri1 35

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 15

Final Pause at End of Cycle

CY2

Cycle 2 parameters family.

Ln2 6

Long Wash Phase [min]

Sh2 10

Short Wash Phase [s] ri2 35

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 15

Final Pause at End of Cycle

CY3

Cycle 3 parameters family.

Ln3 9

Long Wash Phase [min]

Sh3 10

Short Wash Phase [s] ri3 35

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 15

Final Pause at End of Cycle

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.53/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

RE 0

Regeneration cycle disabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 84

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. btd 3

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 68

Tank Temperature Threshold. ttH 2

HISTERESIS of Tank Temperature.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 1

Long Wash Phase [min]

Sh1 36

Short Wash Phase [s]

FP1 4

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 2

Long Wash Phase [min]

Sh2 36

Short Wash Phase [s]

FP2 4

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 3

Long Wash Phase [min]

Sh3 36

Short Wash Phase [s]

FP3 4

Final Pause [s] dPA

Set other parameters.

C F 1

Fahrenheit.

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.54/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT38 MED Prog. 032

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 3

Medical line dishwasher with lock door/hood device. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 92

Boiler Temperature Threshold. bHi 0

Disable boiler high Temperature alarm (

C 2

). bAJ 0

Boiler Temperature Adjust. bSt 0

Booster function not needed. btd 10

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 65

Tub Temperature Threshold. tHi 85

Tank high Temperature limit.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 3

Long Wash Phase [min]

Sh1 35

Short Wash Phase [s] pAI 5

Pause [s] ri1 35

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 60

Final Pause at End of Cycle [s].

CY2

Cycle 2 parameters family.

Ln2 6

Long Wash Phase [min]

Sh2 35

Short Wash Phase [s] pA2 5

Pause [s] ri2 35

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 60

Final Pause at End of Cycle[s].

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.55/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT38 MED

CY3

Cycle 3 parameters family.

Ln3 8

Long Wash Phase [min]

Sh3 35

Short Wash Phase [s] pA3 5

Pause [s] ri3 35

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 60

Final Pause at End of Cycle [s]. dPA

Set other parameters.

rPA 45

Duration of pause after the rinse cycle [s].

6. Switch OFF and then switch ON the machine.

Prog. 032

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 1

Detergent level switches enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.56/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 3

Medical line dishwasher with lock door/hood device. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 92

Boiler Temperature Threshold. bHi 0

Disable boiler high Temperature alarm (

C 2

). bAJ 0

Boiler Temperature Adjust. bSt 0

Booster function not needed. btd 10

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 65

Tub Temperature Threshold. tHi 85

Tank high Temperature limit.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 3

Long Wash Phase [min]

Sh1 35

Short Wash Phase [s] pAI 5

Pause [s] ri1 35

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 60

Final Pause at End of Cycle [s].

CY2

Cycle 2 parameters family.

Ln2 6

Long Wash Phase [min]

Sh2 35

Short Wash Phase [s] pA2 5

Pause [s] ri2 35

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 60

Final Pause at End of Cycle[s].

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.57/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

CY3

Cycle 3 parameters family.

Ln3 8

Long Wash Phase [min]

Sh3 35

Short Wash Phase [s] pA3 5

Pause [s] ri3 35

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 60

Final Pause at End of Cycle [s]. dPA

Set other parameters.

rPA 45

Duration of pause after the rinse cycle [s].

C F 1

Fahrenheit.

6. Switch OFF and then switch ON the machine.

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 3

Medical line dishwasher with lock door/hood device. boi 0

Atmospheric boiler. doo 1

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 92

Boiler Temperature Threshold. bHi 0

Disable boiler high Temperature alarm (

C 2

). bAJ 0

Boiler Temperature Adjust. bSt 0

Booster function not needed. btd 10

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 65

Tub Temperature Threshold. tHi 85

Tank high Temperature limit.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.58/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 3

Long Wash Phase [min]

Sh1 35

Short Wash Phase [s] pAI 5

Pause [s] ri1 35

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 60

Final Pause at End of Cycle [s].

CY2

Cycle 2 parameters family.

Ln2 6

Long Wash Phase [min]

Sh2 35

Short Wash Phase [s] pA2 5

Pause [s] ri2 35

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 60

Final Pause at End of Cycle[s].

CY3

Cycle 3 parameters family.

Ln3 8

Long Wash Phase [min]

Sh3 35

Short Wash Phase [s] pA3 5

Pause [s] ri3 35

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 60

Final Pause at End of Cycle [s]. dPA

Set other parameters.

rPA 45

Duration of pause after the rinse cycle [s].

C F 1

Fahrenheit.

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.59/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 1

Pressure boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 13

Select user interface for LS5 (up to version 3.11 set to

5

)

.

rE 0

Regeneration cycle disabled.

ALr 0

ALARMS NOT ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 82

Boiler Temperature Threshold. bAJ 3

Boiler Temperature Adjust. bSt 2

Booster Function.

5. Modify the cycle parameters:

CY3

Cycle 3 parameters family.

Ln3 1

Long Wash Phase [min]

Sh3 40

Short Wash Phase [s]

6. Switch OFF and then switch ON the machine.

7. Modify Detergent dosage:

GEn

Enter into GEn parameter family. dIn 165

Initial Detergent Dosage. rIn 0

Initial Rinse Aid Dosage. dEt 182

Detergent dispenser works when LOAD SOLENOID VALVE in activated. rAi 61

Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated.

8. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.60/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

PW1-PW2 / WT830 -WT850 USA Prog. 037

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 1

Pot Washer. boi 0

Atmospheric boiler. doo 2

Front loading function. dFL 2

Default values for Pot Washer models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 84

Boiler Temperature threshold. bHi 98

Boiler Temperature high limit. bAJ 0

Boiler Temperature Adjust. tt°C 70

Tub Temperature Threshold. ttH 2

HISTERESIS of Tank Temperature. tHi 80

Tank high Temperature limit.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 5

Long Wash Phase [min]

Sh1 11

Short Wash Phase [s] ri1 23

Rinse Phase Duration [s]

FP1 20

Final Pause at End of Cycle [s].

CY2

Cycle 2 parameters family.

Ln2 9

Long Wash Phase [min]

Sh2 11

Short Wash Phase [s] ri2 23

Rinse Phase Duration [s]

FP2 20

Final Pause at End of Cycle [s].

CY3

Cycle 3 parameters family.

Ln3 14

Long Wash Phase [min]

Sh3 11

Short Wash Phase [s] ri3 23

Rinse Phase Duration [s]

FP3 20

Final Pause at End of Cycle [s]. dPA

Set other parameters.

C F 1

Fahrenheit.

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.61/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT30C (Café Line) Prog. 038

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading door type. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 1

Detergent level switches enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

RE 0

Regeneration cycle disabled.

ALr 1

ALARMS ENABLED.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family. bt°C 84

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. btd 3

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 68

Tank Temperature Threshold. ttH 2

HISTERESIS of Tank Temperature.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 1

Long Wash Phase [min]

Sh1 36

Short Wash Phase [s]

FP1 4

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 2

Long Wash Phase [min]

Sh2 36

Short Wash Phase [s]

FP2 4

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 3

Long Wash Phase [min]

Sh3 36

Short Wash Phase [s]

FP3 4

Final Pause [s] dPA

Set other parameters.

C F 1

Fahrenheit.

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.62/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

WT38PM50 / WT38PM60 Prog. 039

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 1

Pressure boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 90

Boiler Temperature Threshold. btd 10

During stand-by boiler is kept at lower temperature than Temperature Threshold. bSt 0

Booster Function not necessary. tt°C 66

Tank Temperature Threshold. tHi 85

High limit for tank temperature.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 1

Long Wash Phase [min]

Sh1 22

Short Wash Phase [s] ri1 25

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 4

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 2

Long Wash Phase [min]

Sh2 22

Short Wash Phase [s] ri2 25

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 4

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 4

Long Wash Phase [min]

Sh3 22

Short Wash Phase [s] ri3 25

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 4

Final Pause [s]

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.63/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

1.

2.

5.

6.

3.

4.

WT38PM50 / WT38PM60 drn

Drain parameters family.

Idr 30

Initial Drain Phase Duration [s] dPA

Set other parameters.

IPA 5

Initial Pause [s]

6. Switch OFF and then switch ON the machine.

LU7P / LU700P / WTU40P

Prog. 039

Prog. 040

Switch OFF and then switch ON the machine.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 1

Pressure boiler. doo 2

Front loading. dFL 1

Default values for Hood Type models. trc 3

SLOW SOFT START ENABLED b_t 1

Tank heater works only if boiler temperature reached. btF 0

The tank is filled into the traditional way.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

Switch OFF and then switch ON the machine.

Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 84

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. bSt 1

Booster Function.

Modify the cycle parameters:

CY2

Cycle 2 parameters family.

Ln2 1

Long Wash Phase [min]

Sh2 10

Short Wash Phase [s]

CY3

Cycle 3 parameters family.

Ln3 4

Long Wash Phase [min]

Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.64/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LU7A Prog. 041

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 1

Default values for Hood Type models. trc 3

SLOW SOFT START ENABLED b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 82

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. bSt 1

Booster Function.

5. Modify the cycle parameters:

CY2

Cycle 2 parameters family.

Ln2 1

Long Wash Phase [min]

Sh2 10

Short Wash Phase [s]

CY3

Cycle 3 parameters family.

Ln3 4

Long Wash Phase [min]

6. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.65/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS14WS / WT65WS Prog. 042

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 1

Manual Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled (only for dishwashers with non-continuous water softener).

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 78

Boiler Temperature Threshold.

5. Modify Communication and HACCP parameters:

HCP

Enter into

HCP

parameter family and set the following parameters. sEr 9

Dishwasher with incorporated continuous water softener.

6. Switch OFF and then switch ON the machine.

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters: tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 0

Automatic Hood. dFL 1

Default values for Hood Type models. trc 0

(for this appliance SOFT START is NOT possible). b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled (only for dishwashers with non-continuous water softener).

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.66/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

4. Modify Factory parameters:

FAC

Factory parameters family bt°C 90

Boiler Temperature Threshold. bHi 0

Disable boiler high Temperature alarm (

C 2

). bAJ 0

Boiler Temperature Adjust. bSt 0

Booster Function. tHi 85

Tank high Temperature limit.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 2

Long Wash Phase [min]

Sh1 32

Short Wash Phase [s] ri1 35

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 15

Final Pause [s]

CY2

Cycle 2 parameters family.

Ln2 3

Long Wash Phase [min]

Sh2 32

Short Wash Phase [s] ri2 35

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 15

Final Pause [s]

CY3

Cycle 3 parameters family.

Ln3 5

Long Wash Phase [min]

Sh3 32

Short Wash Phase [s] ri3 35

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 15

Final Pause [s] dPA

Set other parameters.

IPA 4

Initial Pause [s]

6. Modify Communication and HACCP parameters:

HCP

Enter into

HCP

parameter family and set the following parameters. sEr 9

Dishwasher with incorporated continuous water softener.

7. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.67/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LS6WS Prog. 044

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Undercounter like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 9

Select user interface hood type model (up to version 3.11 set to

1

)

.

rE 0

Regeneration cycle disabled (only for dishwashers with non-continuous water softener).

ALr 1

Alarms enabled.

3. Modify Communication and HACCP parameters:

HCP

Enter into

HCP

parameter family and set the following parameters. sEr 9

Dishwasher with incorporated continuous water softener.

4. Switch OFF and then switch ON the machine.

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Under counter like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled (only for dishwashers with non-continuous water softener).

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.68/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 90

Boiler Temperature Threshold. bHi 0

Disable boiler high Temperature alarm (

C 2

). bAJ 0

Boiler Temperature Adjust. bSt 0

Booster function not needed. btd 10

During stand-by boiler is kept at lower temperature than Temperature Threshold. tt°C 65

Tub Temperature Threshold. tHi 85

Tank high Temperature limit.

5. Modify the cycle parameters:

CY1

Cycle 1 parameters family.

Ln1 4

Long Wash Phase [min]

Sh1 10

Short Wash Phase [s] ri1 35

Rinse Phase Duration [s] dr1 40

Drain [s]

FP1 15

Final Pause at End of Cycle

CY2

Cycle 2 parameters family.

Ln2 6

Long Wash Phase [min]

Sh2 10

Short Wash Phase [s] ri2 35

Rinse Phase Duration [s] dr2 40

Drain [s]

FP2 15

Final Pause at End of Cycle

CY3

Cycle 3 parameters family.

Ln3 9

Long Wash Phase [min]

Sh3 10

Short Wash Phase [s] ri3 35

Rinse Phase Duration [s] dr3 40

Drain [s]

FP3 15

Final Pause at End of Cycle

6. Modify Communication and HACCP parameters:

HCP

Enter into

HCP

parameter family and set the following parameters. sEr 9

Dishwasher with incorporated continuous water softener.

7. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.69/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

FL620 / LV6 / WT30 6000W ATM Prog. 046

3.

1.

2.

Switch OFF and then switch ON the machine.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

Switch OFF and then switch ON the machine.

LU700A / WTU40A Prog. 047

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Hood Type like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 1

Default values for Hood Type models. trc 3

SLOW SOFT START ENABLED b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled.

ALr 1

Alarms enabled.

3. Switch OFF and then switch ON the machine.

4. Modify Factory parameters:

FAC

Enter into FAC parameter family and change boiler threshold. bt°C 82

Boiler Temperature Threshold. bAJ 0

Boiler Temperature Adjust. bSt 1

Booster Function.

5. Modify the cycle parameters:

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.70/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

LU700A / WTU40A

CY2

Cycle 2 parameters family.

Ln2 1

Long Wash Phase [min]

Sh2 10

Short Wash Phase [s]

CY3

Cycle 3 parameters family.

Ln3 4

Long Wash Phase [min]

6. Switch OFF and then switch ON the machine.

FL620WS / LV6WS / WT38WS

Prog. 047

Prog. 048

1. Switch OFF and then switch ON the machine.

2.

CFG

Enter into CFG parameter family and set the following parameters. tYP 0

Undercounter like working cycles. boi 0

Atmospheric boiler. doo 2

Front loading. dFL 3

Default values for Undercounter models. trc 1

SOFT START ENABLED. b_t 1

Tank heater works only if boiler temperature reached. btF 75

Enable filling tank by means of rinsing cycles.

LES 0

Detergent level switches not enabled.

UI 8

ACTIVE function disabled (up to version 3.11 set to

0

)

.

rE 0

Regeneration cycle disabled (only for dishwashers with non-continuous water softener).

ALr 1

Alarms enabled.

3. Modify Communication and HACCP parameters:

HCP

Enter into

HCP

parameter family and set the following parameters. sEr 9

Dishwasher with incorporated continuous water softener.

4. Switch OFF and then switch ON the machine.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.71/88

Electrolux

EFS - Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

11. DEFAULT VALUES

Default 1 – Hood Type

ON/OFF +

CYCLE1 keys

GEn

→ Cnt

ON/OFF +

CYCLE2 keys

FAC

→ CY1 → CY2 → CY3 → Drn → DPA → Ron → HCP → CFG

↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ dbG

SEr= 1 tYP= 0 t 1= 15

Adr= 1 Boi= 0 t 2= 200

Prn= 1 Doo= 1 t 3= 15

Bt = 90 DFL= - t 4= 10

DIn= 90 CYC Bt°C= 78 Ln1= 0 Ln2= 0 Ln3= 1 Idr= 40 IpA= 0 REL

RIn= 10 cyc BtH= 2 Sh1= 35 Sh2= 45 Sh3= 40 Fdr= 60 DLY= 3 rLs

DEt= 8 RSt BHi= 96 PA1= 4 PA2= 4 PA3= 4

RAi= 4 NCY BLo= 1 Pr1= 0 Pr2= 0 Pr3= 0

Pdr= 0 CA\\ rPA= 0 C 8 drn BFL= 5 Ri1= 16 Ri2= 16 Ri3= 16 rCY BAJ= 4 cr1= 0 cr2= 0 cr3= 0 nrE BP = 1 Dr1= 16 Dr2= 16 Dr3= 16

BSt= 2 FP1= 0 FP2= 0 FP3= 0

Btd= 0 Bt3= 0 tt°C= 63 ttH= 5 tHi= 75 tLo= 1 tFL= 20

C F= 0 F21

Rit= 0

PPL= 0

CDE= 5

BH = 10 trc= 0 t 5= 20 tt = 68 B_t= 1 t 6= 20 tH = 10 BtF= 75 AL_= 0

LES= 0 Ith= 100

UI = 9 rE = 0

ALr= 1

AAG= 0

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.72/88

Electrolux

EFS - Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

Default 2 - POT WASHER

ON/OFF +

CYCLE1 keys

ON/OFF +

CYCLE2 keys

GEn

→ Cnt

FAC

CY1

→ CY2 → CY3 → Drn → DPA → Ron → HCP → CFG dbG

↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓

DIn=240 CYC

RIn= 18 cyc

DEt= 16 RSt

RAi= 7 NCY

Bt°C= 78 Ln1= 2 Ln2= 5 Ln3= 8 Idr= 40 IpA= 2 REL

BtH= 2 Sh1= 34 Sh2= 34 Sh3= 34 Fdr= 60 DLY= 3 rLS

BHi= 96 PA1= 4 PA2= 4 PA3= 4

BLo= 1 Pr1= 0 Pr2= 0 Pr3= 0

Pdr= 0 CA\\ rPA= 0 C 8

SEr= 1 tYP= 1 t 1= 15

Adr= 1 Boi= 0 t 2= 200

Prn= 1 Doo= 2 t 3= 15

Bt = 90 DFL= - t 4= 10 drn rCY nrE

BFL= 5 Ri1= 20 Ri2= 20 Ri3= 20

BAJ= 4 cr1= 0 cr2= 0 cr3= 0

BP = 1 Dr1= 20 Dr2= 20 Dr3= 20

C F= 0 F21

Rit= 0

PPL= 0

BSt= 4 FP1= 0 FP2= 0 FP3= 0

Btd= 0

tt°C= 63

ttH= 5

tHi= 75

Bt3= 0

CdE= 5

BH = 10 trc= 0 t 5= 20 tt = 68 B_t= 1 t 6= 20 tH = 10 BtF= 75 AL_= 0

LES= 0 Ith= 100

UI = 9 rE = 0

ALr= 1

AAG= 0

tLo= 1

tFL= 40

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.73/88

Electrolux

EFS - Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

Default 3 - UNDERCOUNTER

ON/OFF +

CYCLE1 keys

ON/OFF +

CYCLE2 keys

GEn

→ Cnt

FAC

CY1

→ CY2 → CY3 → Drn → DPA → Ron → HCP → CFG dbG

↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓

DIn= 50 CYC

RIn= 10 cyc

DEt= 8 RSt

RAi= 4 NCY

Bt°C= 80 Ln1= 1 Ln2= 1 Ln3= 3 Idr= 30 IpA= 0 REL

BtH= 2 Sh1= 10 Sh2= 40 Sh3= 40 Fdr= 60 DLY= 3 rLS

BHi= 96 PA1= 4 PA2= 4 PA3= 4

BLo= 1 Pr1= 0 Pr2= 0 Pr3= 0

Pdr= 0 CA\\ rPA= 0 C 8

SEr= 1 tYP= 0 t 1= 15

Adr= 1 Boi= 0 t 2= 200

Prn= 1 Doo= 2 t 3= 15

Bt = 90 DFL= - t 4= 10 drn rCY nrE

BFL= 5 Ri1= 16 Ri2= 16 Ri3= 16

BAJ= 0 cr1= 0 cr2= 0 cr3= 0

BP = 1 Dr1= 30 Dr2= 30 Dr3= 30

BSt= 2 FP1= 0 FP2= 0 FP3= 0

Btd= 3

tt°C= 63

ttH= 5

tHi= 75

tLo= 1

tFL= 20

Bt3= 0

C F= 0 F21

Rit= 0

PPL= 0

CdE= 5

BH = 10 trc= 1 t 5= 20 tt = 68 B_t= 1 t 6= 20 tH = 10 BtF= 75 AL_= 0

LES= 0 Ith= 100

UI = 9 rE = 0

ALr= 1

AAG= 0

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.74/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

12. USER INTERFACE AND MAIN BOARD CONNECTORS

12.1 MAIN MALFUNCTIONS NOT DUE TO THE MAIN BOARD

The display shows CLOSEwith door/hood closed

A cycle fails to start

After replacing the main board only the 3 rd

cycle starts

Cycle time longer than that foreseen

Noisy wash pump (only on HT and PP versions)

Check door/hood micro/sensor

Check the user interface buttons (have they remained pressed? etc.)

Is a user interface button extension missing?

The main board is still configured for LS5/WT4.

Does the boiler work?

Is the feed water at 50°C?

Check the current for single phase during operation.

KEY

CN1

Rinse pump/wash pump/solenoid valve outputs

CN2

Pressure/atmospheric

CN3

CN5

CN8

CN10

ECOTEMP transformer and detergent/rinse aid dispenser outputs

Tank/boiler temperature sensor inputs

Energy peak controller input

Safety and upper/lower limit switch input

CN11

CN12

Gear unit current control input - Gear unit polarity inversion/connection

User interface inputs/outputs

CN15

Overflow/tank level/board feed input

CN16

User interface inputs/outputs and hood/door sensor input

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.75/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

KEY

CN1

CN2

Rinse pump/wash pump/solenoid valve outputs dishwasher solenoid valve connection

CN3

ECOTEMP transformer and detergent/rinse aid dispenser outputs

CN5

CN8

Tank/boiler temperature sensor inputs

Energy peak controller input

CN12

User interface inputs/outputs

CN15

Overflow/tank level/board feed input

CN16

User interface inputs/outputs and hood/door sensor input

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.76/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

KEY

CN1

Rinse pump/wash pump/solenoid valve outputs

CN2

Pressure/atmospheric

CN3

CN5

CN7

CN8

CN10

ECOTEMP transformer and detergent/rinse aid dispenser outputs

Tank/boiler temperature sensor inputs

Hand safety system microswitch input

Energy peak controller input

Safety and upper/lower limit switch input

CN11

CN12

Hand safety system input - Gear motor current control input - Gear motor polarity inversion connection

User interface inputs/outputs

CN15

Overflow/tank level/board feed input

CN16

User interface inputs/outputs and hood/door sensor input

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.77/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

KEY

CN1

Rinse pump/wash pump/solenoid valve outputs

CN2

Pressure/atmospheric

CN3

CN5

Detergent/rinse aid dispenser outputs

Tank/boiler temperature sensor inputs

CN8

CN11

Energy peak controller input

Water feed solenoid valve output

CN12

User interface inputs/outputs

CN15

Overflow/tank level/board feed input

CN16

User interface inputs/outputs and hood/door sensor input

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.78/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

KEY

CN1

CN2

Rinse pump/wash pump/solenoid valve outputs dishwasher solenoid valve connection

CN3

Detergent/rinse aid dispenser outputs

CN5

CN7

Tank/boiler temperature sensor inputs

Detergent/rinse aid level sensors input

CN8

CN9

CN11

CN12

Energy peak controller input

Salt receptacle drain pump and low pressure solenoid valve outputs

Brine solenoid valve output

User interface inputs/outputs

CN15

Overflow/tank level/board feed input

CN16

User interface inputs/outputs and hood/door sensor input

CN17

Door microswitch connection

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.79/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

KEY

CN1

Rinse pump/wash pump/solenoid valve outputs

CN2

Pressure/atmospheric

CN3

CN5

CN7

CN8

CN9

ECOTEMP transformer and detergent/rinse aid dispenser outputs

Tank/boiler temperature sensor inputs

Detergent/rinse aid level sensors input

Energy peak controller input

Salt receptacle drain pump and low pressure solenoid valve outputs

CN11

CN12

Door lock electromagnet and brine solenoid valve output

User interface inputs/outputs

CN15

Overflow/tank level/board feed input

CN16

User interface inputs/outputs and hood/door sensor input

CN17

Door microswitch connector

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.80/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

KEY

CN1

Rinse pump/wash pump/solenoid valve outputs

CN2

Pressure/atmospheric

CN3

CN5

CN8

ECOTEMP transformer and detergent/rinse aid dispenser outputs

Tank/boiler temperature sensor inputs

Energy peak controller input

CN11

CN12

Hood lock electromagnet output

User interface inputs/outputs

CN15

Overflow/tank level/board feed input

CN16

User interface inputs/outputs and hood/door sensor input

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.81/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

13. ALARM MESSAGES AND TROUBLESHOOTING

A Alarms that stop the dishwasher

A 1

Want of water

Is the water cock open?

Does the water load solenoid valve work?

Is the water feed flow a min. of 5 l/min?

Is the water inlet filter clean?

Is the load solenoid valve filter clean?

Is the overflow inserted?

Is the main board (ATM-PRES) CN2 connector correctly positioned?

Do the tank/boiler pressure switches work properly?

B Alarms that don't stop the dishwasher

B 1 Drain not efficient

Has the overflow been removed?

Is the water drain blocked?

Is the drain pump blocked?

Are the air trap and tank pressure switch clean?

Is there a constriction in the drain tube?

Is the pump breather pipe returning to the tank clogged or constricted?

Does the tank pressure switch work properly?

Is there a hole in the drain tube (only for versions with drain pump)?

B 2

Overflow alarm

Is the water drain blocked?

Are the air trap and tank pressure switch clean?

Does the tank pressure switch work properly?

Is the load solenoid valve blocked? (E1 - LOAD_EV)

Is the load solenoid valve relay stuck? (RL8 - LOAD_EV)

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.82/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

C Alarms that stop the functioning and suggest to call the service

C 1 Boiler temperature rise too fast

Does the boiler level sensor work properly? The boiler could be empty.

Are non-original power resistances installed?

C 2

Boiler temperature too high

Has the boiler temperature been changed (btC - increased above 90°C)?

Has the software alarm value been modified (bHi)?

Does the boiler level sensor work properly?

Is the boiler relay stuck (see RL2, RL3, RL4)?

C 3 Tank temperature too high

Is the feed water above 60°C?

Has the software alarm value been modified (bHi)?

Is the rinse water temperature too high?

Is the tank relay stuck (RL5 - TUB_HEAT)?

C 4 Tank temperature sensor out of order

Is the temperature sensor broken or disconnected (NT1)?

Is the temperature sensor connector correctly inserted?

C 5

Tank temperature sensor out of order

Is the temperature sensor short-circuited (NT1)?

C 6 Boiler temperature sensor out of order

Is the temperature sensor broken or disconnected (NT2)?

Is the temperature sensor connector correctly inserted?

C 7 Boiler temperature sensor out of order

Is the temperature sensor short-circuited (NT2)?

C 8

During rinse phase boiler doesn't empty

Are the rinse arms clogged?

Does the rinse pump work correctly?

Is there water in the level sensor tube?

Is there scale in the boiler?

Does the boiler level sensor work properly?

CAUTION: RESETTING THIS ALARM WITHOUT FIRST ELIMINATING THE CAUSE IS

DANGEROUS; THE BOILER HEATING ELEMENTS COULD WORK DRY, FURTHER DAMAGING

THE INTERNAL PARTS OF THE DISHWASHER.

CAUTION: C8 IT MUST BE MANUALLY RESET AFTER ELIMINATING THE CAUSE OF THE

MALFUNCTION.

C 9

Automatic hood out of order

See par. C1 - Alarm codes for automatic hood type dishwashers

.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.83/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

C.1

Alarm codes for automatic hood type dishwashers

When the alarm

C9 appears, to facilitate fault-finding another parameter providing a more detailed indication has been introduced.

The parameter is

AL

and is found in the

DBG family

.

The possible cause of the anomaly can be found (see table below) according to the value of the parameter

AL

.

With pot washers the cause that generated a b3

type alarm can also be found.

E.g.: With an automatic hood type the alarm

C 9

appears.

Access the parameter

AL

in the

DBG

family.

AL_8

⇒ the top limit switch could be disconnected or interrupted.

S3: FC_DW

(hood CLOSE)

S5: FC_UP (hood OPEN)

S1: DOOR_CLOSE

AL_1

AL_2

Appears with hood closed if the top limit switch (FC_UP) cuts in.

During lifting, the bottom limit switch (FC_DW) has not returned to the rest position.

The limit switch must return to the rest position within a time given by the parameter

t_5

: a) check that the motor works.

Appears with hood closed, if:

- the bottom limit switch (S3) returns to the rest position;

- the top limit switch (S5) cuts in;

- S3’’ does not cut in. b 3

During the initial lifting phase the bottom limit switch

(S3) must return to the rest position within a time given by the parameter

t_5

 otherwise the alarm

b 3 appears.

- S3 could be stuck.

- S5’ could be disconnected.

On installation this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board.

Appears if during lifting S3’’ does not return to the rest position within a time t 1.

AL_3

AL_4

-

Appears if the bottom limit switch (FC_DW) cuts in during lifting.

DOC. NO. 5956.446.06 b 3

©Copyright 2005 by

Electrolux Professional

P.84/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

AL_5

AL_6

AL_7

AL_8

AL_9

AL_10

AL_11

AL_12

AL_13

(Polarity/motor rotation direction inverted?!).

TIMEOUT-

The time taken for hood lifting was more than the time fixed by parameter

t_2

: a) check that the motor works.

The hood is open but the bottom limit switch

(FC_DW) has cut in.

Appears if with hood fully open the "door closed" microswitch cuts in.

During lowering, the top limit switch (FC_UP) has not returned to the rest position.

The limit switch must return to the rest position within a time given by parameter

t_6

: a) check that the motor works; b) (Polarity/motor rotation direction inverted?!).

-

Appears if the bottom limit switch (S3) cuts in during lifting.

On installation this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board.

TIMEOUT-

The time taken for lifting was more than the time fixed by parameter

t 2

.

Check correct operation of the: a) motor (thermal protection N7); b) top limit switch (S5 and S5’).

Appears with hood fully open, if:

- the limit switch (S5) returns to the rest position;

- the bottom limit switch (S3) cuts in;

- S3’’ cuts in.

Appears if with hood fully open the "door closed" microswitch cuts in.

- S5 could be disconnected.

b 3

During the initial lowering phase the top limit switch

(S5) must return to the rest position within a time given by the parameter

t_6

 otherwise the alarm b 3 appears.

- S5 could be stuck.

- S3’ could be disconnected.

On installation, this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board.

Appears if the bottom limit switch S3 cuts in before S3" during lowering.

Appears if the top limit switch (FC_UP) cuts in during lowering.

(Polarity/motor rotation direction inverted?!). b 3

Appears if the top limit switch (S5) cuts in during lowering.

On installation, this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board.

TIMEOUT-

The time taken for hood closing was more than the time fixed by parameter t_2

: a) check that the motor works.

TIMEOUT-

The time taken for lowering was more than the time fixed by parameter t_2

.

- S3’ could be disconnected.

-

Appears during hood lowering if, after S3’’ cuts in, the bottom limit switch S3 does not cut in within the time fixed by parameter t 3

.

-

The two hand safety contacts K and K' must be both closed or both open. If this does not occur the alarm appears.

- One of the two relays (K or K’) could be stuck or disconnected. (See parameter t 4

)

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.85/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

AL_14

AL_20

AL_21

AL_22

AL_23

AL_24

AL_25

Limit switch combination not allowed: top limit switch (FC_UP) and bottom limit switch (FC_DW) activated at the same time!

During lifting, the current absorbed by the lifting motor has exceeded the threshold (see parameter

Ith

): a) excessive mechanical force during lifting.

During lowering, the current absorbed by the lifting motor has exceeded the threshold (see parameter

Ith

): a) excessive mechanical force during lowering.

The hood should be stopped but the card detects a high current absorption by the lifting motor:

-

-

Limit switch combination not allowed.

Appears if one of the following combinations occurs:

- top limit switch (S5) and bottom limit switch (S3) both activated (S3 and S5 could be disconnected);

- top limit switch S5 and S3’’ both cut in;

- bottom limit switch (S3) cut in but not S3’’.

- a) the relay RL18/RL19 could be stuck; b) feeder connector CN32 could be disconnected.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.86/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

D Alarms that don't stop the functioning, but suggest to call the service

E 1

Communication error

Is the connection between main board and control panel correct? Are the connectors correctly connected?

Are connector contacts clean?

E 2 Tank temperature low

Does the tank heating element work properly?

Are the connectors correctly connected?

Are the dishwasher feed voltage and current correct?

Is the relay RL5 on the board disconnected or faulty?

E 3 Boiler temperature low

Does/do the boiler heating element/s work properly?

Are the connectors correctly connected?

Does the possible remote control switch connected to the heating element work correctly?

Is there power at the remote control switch input terminals?

Does relay RL2 on the board work properly?

CAUTION: IF THERE IS A MALFUNCTION ON RELAY RL2 AND THE BOILER HEATING

ELEMENTS ARE FED BY MEANS OF A REMOTE CONTROL SWITCH, THE BOARD DOES

NOT HAVE TO BE REPLACED; JUST MOVE THE BOILER HEATING ELEMENT CONNECTOR

TO ONE OF THE TWO FREE POSITIONS ON THE BOARD.

CAUTION: WHEN ONE BRANCH OF THE HEATING ELEMENT DOES NOT WORK AND THE

OTHER TWO CONTINUE TO FUNCTION, ON REACHING THE SET TEMPERATURE VALUE,

ALARM 3 DISAPPEARS AND REAPPEARS IN THE SUBSEQUENT RINSE PHASE. THIS ALSO

OCCURS WHEN A PHASE IS MISSING.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.87/88

Electrolux

EFS – Dishwashing Systems Platform

Electrolux Professional

Electronic Dishwasher

SERVICE MANUAL

E Alarms that stop the dishwasher for models with incorporated continuous water softener

f21 Water softener operation errors

This alarm appears in case of malfunctioning in the continuous water softener.

F22

Communication errors between the mother board and softener board

This alarm appears in case of problems in communication between the mother board and water softener board; check the connection between mother board connector J1 and water softener connector ST8.

To facilitate the finding of faults signalled by alarm

F21

, another parameter providing a more detailed indication of the possible cause of malfunction has been introduced in the

RoN family (see table below). f21 1 Water softener conductivity sensor short-circuit

Two or more water softener conductivity sensors are short-circuited. Check the connections between the water softener board and sensors, replacing the connection wiring if necessary. f21 2

Water softener conductivity sensors open

One or more water softener conductivity sensors are disconnected. Check the connections between the water softener board and sensors, replacing the connection wiring if necessary. f21 3 Resin temperature sensor malfunction

Replace the water softener electronic board. f21 4 Water softener electronic board malfunction

Replace the water softener electronic board. f21 6

Salt water filling malfunction

The salt water container in the water softener was not completely filled within the set max. filling time.

Make sure:

− the water cock is open

− the water filling solenoid valve works correctly the salt container solenoid valve works correctly the feed water pressure is at least 50 kPa / 0.5 bar the water inlet filter is clean the filling solenoid valve filter is clean the salt container cap is properly closed the mother board (ATM-PRES) connector CN2 is correctly positioned the water softener board connector ST5 is correctly positioned. f21 7 Inefficient resin washing

After carrying out the maximum permissible number of resin washes, the resins are not sufficiently cleaned by the salt water used to regenerate them.

Make sure:

− the water filling solenoid valve works correctly

− the feed water pressure is at least 50 kPa / 0.5 bar the water inlet filter is clean the filling solenoid valve filter is clean the mother board (ATM-PRES) connector CN2 is correctly positioned.

DOC. NO. 5956.446.06 ©Copyright 2005 by

Electrolux Professional

P.88/88

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project