Serial/CAN-Gateway
SerCAN-ARM7/RMD
User Manual
EM
S
Thomas Wünsche
Serial/CAN Gateway SerCAN-ARM7/RMD
User manual SerCAN-ARM7/RMD
Document version: 1.03
Documentation date: May 05th, 2011
This document describes the functionality of the SerCAN-ARM7/RMD hardware with firmware version 2.00. Please contact EMS Dr. Thomas
Wünsche, if you have a module with different firmware.
No part of this document or the software described herein may be reproduced in any form without prior written agreement from EMS Dr.
Thomas Wünsche.
For technical assistance please contact:
EMS Dr. Thomas Wünsche
Sonnenhang 3
D-85304 Ilmmünster
Tel. +49-8441-490260
Fax +49-8441-81860
Our products are continously improved. Due to this fact specifications may be changed at any time and without announcement.
WARNING: EMS hardware and software may not be used in applications where damage to life, health or private property may result from failures in or caused by these components.
2
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD
Content
1 Overview
1.1 Features
1.2 General Description
1.3 Ordering Information
2 Handling
2.1 Connection
2.2 Operation
2.3 Configuration
2.3.1 Configuration File
2.3.2 Programming the Device
2.4 LED
3 Technical Data
3.1 Pin Assignment
3.2 Limiting Values
3.3 Nominal Values
4 Appendix
4.1 Configuration File Example
4.2 Standard CAN Baud Rates
Serial/CAN Gateway
15
15
15
13
13
14
14
7
7
10
12
7
7
7
5
5
5
5
EMS Dr. Thomas Wünsche
3
Serial/CAN Gateway
THIS PAGE INTENTIONALLY LEFT BLANK
SerCAN-ARM7/RMD
4
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD Serial/CAN Gateway
1 Overview
1.1 Features
• Connection of a CAN network to a RS232 interface
• Filtering of CAN messages
• CAN bus activity displayed by LED
• Configuration via RS232 connection
• Wiring using a multiway connector
• Available also with low speed CAN transceiver NXP TJA1054
1.2 General description
The Serial/CAN gateway SerCAN-ARM7 connects a CAN network to a RS232 interface. The capability of having different baud rates on the CAN side as well as on the RS232 side marks the devices a versatile tool for a lot of applications. Bandwith differences between
CAN and RS232 may be overcome by CAN message filtering.
The device is also available with a low speed physical CAN interface using NXP CAN transceiver TJA1054 (SerCAN-ARM7/RMD/LS).
The device is configured via the RS232 interface. Due to the intuitive structure of the configuration file in ASCII format, programming and administration is easy.
1.3 Ordering information
12-20-202-20
12-20-203-20
SerCAN-ARM7/RMD
SerCAN-ARM7/RMD/LS
EMS Dr. Thomas Wünsche
5
Serial/CAN Gateway
THIS PAGE INTENTIONALLY LEFT BLANK
SerCAN-ARM7/RMD
6
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD Serial/CAN Gateway
2 Handling
2.1 Connection
SerCAN-ARM7 has a multiway connector for flexible wiring of the
CAN interface and the power supply. The RS232 interface has a standard SUB-D-9 male connector and is used for normal operation as well as for the configuration purpose.
The connector assignment of the multiway connector and the RS232 interface is described in chapter "3.1 Pin assignment".
2.2 Operation
To start up the gateway just connect the power supply, the device starts up automatically. As soon as the automatic diagnostic process is successfully completed the green power LED lites up permanently.
Important note: Ex factory the device offers no configuration and must be configured before its first run. Configuration instructions for the gateway are located in chapter "2.3 Configuration".
2.3 Configuration
The gateway configuration process consists of two steps:
• Creating a configuration file
• Loading the configuration into the device
2.3.1 Configuration File
The configuration file is a text file with the extension *.gcf. This file holds all data needed by the gateway for operation. A complete sample configuration is located in chapter "4.1 Configuration File
Example".
The values can either be entered in decimal or hexadecimal notation. Using the hexadecimal notation, the character 'x' has to be entered directly before the particular value.
EMS Dr. Thomas Wünsche
7
Serial/CAN Gateway SerCAN-ARM7/RMD
Some parameters are optional. If they are not defined, the gateway uses default settings.
In the following all parameters are listed and described.
#
comment
The configuration file can be provided with comments. Comments are prefaced with the character '#' and they end with the particular line.
Example:
# 1st comment key = value # 2nd comment
version version
The version number indicates the file format of the configuration file.
It must be 1 for the actual version.
Example:
version=1
configname name assigned to the configuration
For easier identification of the programmed settings, the configration can be labeled. The configuration name must not have more than 32 characters and must not contain space characters or tabs. If this key is missing, no name will be assigned.
Example:
configname=MyOwnConfig
8
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD Serial/CAN Gateway
canbaudrate CAN bit timing
The CAN bit timing key indicates the speed of the CAN interface.
This key is mandatory and is related directly to the CANBTR0 register of the used controller LPC2119. This allows most flexible customization of the baudrate settings. The basic CAN clock is
48MHz.
Example:
# 500 kBaud canbaudrate = x001c0005
serialbaudrate serial baud rate
The serial baudrate key is optional. If it is not set, the default baudrate of 57600 baud will be used. A particular value is calculated with the following equation: serialbaudrate = 48000000/(16*BAUDRATE)
The results for some standard values are given below:
9600 Baud
19200 Baud
38400 Baud
57600 Baud
115200 Baud
: 312
: 156
: 78
: 52
: 26
The line settings for the RS232 interface is always 8 data bits, no parity, 1 stop bit (8N1).
The maximum usable baud rate is limited by the serial transceiver chip to 115200 baud.
Please note, that if a serial baud rate is programmed, which is not supported by the PC used for the configuration process, a reconfiguration may become hard to accomplish.
Example:
# serial baud rate set to 57600 serialbaudrate=52
EMS Dr. Thomas Wünsche
9
Serial/CAN Gateway SerCAN-ARM7/RMD
bus off bus off behavior
This key specifies the period of time in milliseconds, which will pass by until the gateway gets bus on again after a bus off condition has occured. If this value is not defined, the device remains in bus off state. If a bus off time of 0 milliseconds is set, the gateway tries immediately to get bus on again.
Example:
busoff=100 s filter, xfilter filter key
This key defines which received CAN messages will be filtered out or not. Either a particular identifier or a range of identifiers can be specified. A message which should pass to the RS232 interface must have a filter rule set. The "sfilter" key relates to 11bit identifier messages, whereas "xfilter" relates to 29bit identifier.
Example:
# A range of 11bit messages starting with id 0 and
# ending with id 100h will pass the filter.
sfilter=x0-x100
# A range of 29bit messages starting with id 100h and
# ending with id 1000h will pass the filter.
xfilter=x0-x10
2.3.2 Programming the Device
SerCAN-ARM7 is programmed by means of the configuration software. It offers the possibility to configure the gateway via the
RS232 interface. A "nullmodem" cable has to be used to connect to the host PC.
The "Program Settings" have to be set to:
• SerCAN-ARM7/RMD
• Program configuration
• a configuration file
10
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD Serial/CAN Gateway
The "Interface Settings" have to be set to:
• Use RS232 interface
• the used PC serial interface port
• the serial baudrate used by the SerCAN-ARM7 device
Within the "Device Settings" the serial number of the SerCAN-ARM7 has to be set. The serial number can be found on a label on the rear side of the device.
After all settings are made a click on the "Process" button starts the download. Do not remove power from the device until the process has finished.
Screenshot of the download tool:
EMS Dr. Thomas Wünsche
11
Serial/CAN Gateway SerCAN-ARM7/RMD
2.4 LED
The device status is displayed by three LEDs.
Power
On
The device is CAN bus on and in normal operation mode
Off The device is CAN bus off
Blinking The device is in programming mode
CAN Active
On There is CAN bus activity
Off There is no CAN bus activity
12
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD Serial/CAN Gateway
3 Technical Data
3.1 Pin Assignment
Pin Assignment multiway connector SerCAN-ARM7/RMD
Pin
1
6
7
8
2
3
4
5
Signal
+24V
GND
GND
CAN_H
CAN_L
GND
GND
GND
Description
+24 Volt power supply
Ground*
Ground*
CAN high bus line
CAN low bus line
Ground*
Bootloader
(connect to Vcc to enter bootloader mode)
Bootloader
(connect to GND to enter bootloader mode)
Pin Assignment multiway connector SerCAN-ARM7/RMD/LS
Pin Signal Description
1
2
3
4
5
6
+24V
GND
GND
CAN_H
CAN_L
GND
+24 Volt power supply
Ground*
Ground*
CAN high bus line
CAN low bus line
7 RTH
Ground*
Connected with Pin 4 by a 5k6 resistor and
RTH pin of TJA1054 CAN transceiver
8 RTL Connected with Pin 5 by a 5k6 resistor and
RTL pin of TJA1054 CAN transceiver
*internal connected
EMS Dr. Thomas Wünsche
13
Serial/CAN Gateway SerCAN-ARM7/RMD
Pin assignment RS232
Pin
1
8
9
6
7
4
5
2
3
Signal
RxD
TxD
GND
RTS
CTS
Description
not connected
Receive signal
Transmit signal
not connected
Ground
not connected
not used
not used
not connected
3.2 Limiting Values
Parameter
Storage temperature
Operating temperature
Supply voltage
3.3 Nominal Values
Parameter
Supply voltage
CAN Baudrates
Min.
Max.
Unit
-20 80 °C
0 60
-100 30
°C
V
Min.
Max.
Unit
10 30 V
10 1000
kBit/s
14
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD Serial/CAN Gateway
4 Appendix
4.1 Configuration File Example
# Serial/CAN Gateway SerCAN-ARM7 configuration file
# Version number of configuration file version=1
# CAN baud rate set to 500kBaud canbaudrate=x001C0005
# RS232 baud rate set to 57.6 kBaud serialbaudrate=52
# set CAN bus off recovery time to 500ms busoff=500
# filter settings
# all 11bit CAN identifier are routed sfilter=x0-x7FF
# all 29bit CAN identifiers are routed xfilter=x0-x1FFFFFFF
4.2 Standard CAN Baud Rates
baud rate
1000 kBaud
800 kBaud
500 kBaud
250 kBaud
125 kBaud
100 kBaud
50 kBaud
20kBaud
10 kBaud
canbaudrate value
0x00140005
0x00160005
0x001C0005
0x001C000B
0x001C0017
0x001C001D
0x001C003B
0x001C0095
0x001C012B
EMS Dr. Thomas Wünsche
15
Serial/CAN Gateway SerCAN-ARM7/RMD
4.3 Serial Protocol Specification
A block oriented protocol is used for message exchange between
RS232 and CAN.
Format of a data block:
Start
Type
Length Data Checksum End
1 byte 1 byte 1 byte
'length' - 4 bytes
2 bytes 1 byte
The 'length' byte counts the number of bytes in the fields 'type',
'length', 'data' and 'checksum'. The two checksum bytes contain the byte by byte summarization of the fields 'type', 'length' and 'data'.
A number of special characters are used. Reserved characters have values less or equal 7.
The following three special characters are used:
Special character Value Description
BEGINOFDATA 0x00
Marks the start of a block
ENDOFDATA 0x01
Marks the end of a block
ESCAPE 0x02 The following character is no special character. This allows the transmission of special characters in the fields 'type',
'length', 'data' and 'checksum'.
In case that a special character has to be transmitted within the data field, it must be preceeded by an ESCAPE character and the most significant bit of the character has to be set.
Example: Transmission of 0x01
Transmitted is 0x02 (ESCAPE) followed by 0x81 (0x01|0x80).
16
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD Serial/CAN Gateway
The meaning of the bytes in the 'data' field is indicated by the 'type' field.
Type
Value Description
CAN 0x08
Denotes a CAN message with 11bit identifier
XCAN 0x09 Denotes a CAN message with 29bit identifier
A message block of type 'CAN' has the following structure:
ID RTR
Length Data
2 bytes low byte first
1 byte
0xFF: RTR frame
0x7F: data frame
1 byte data frame: Number of data bytes corresponding to 'Length'
RTR frame: 0 bytes
A message block of type 'XCAN' has the following structure:
ID RTR
Length Data
4 bytes low byte first
1 byte
0xFF: RTR frame
0x7F: data frame
1 byte data frame: Number of data bytes corresponding to 'Length'
RTR frame: 0 bytes
EMS Dr. Thomas Wünsche
17
Serial/CAN Gateway SerCAN-ARM7/RMD
THIS PAGE INTENTIONALLY LEFT BLANK
18
EMS Dr. Thomas Wünsche
SerCAN-ARM7/RMD
THIS PAGE INTENTIONALLY LEFT BLANK
Serial/CAN Gateway
EMS Dr. Thomas Wünsche
19
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project