XM98PAH2
Retro-Reflex Sensor
XM98PAH2
Part Number
LASER
Technical Data
Optical Data
Range
15000 mm
Min. Distance to Reflector
80 mm
Reference Reflector/Reflex Foil
Smallest Recognizable Part
Switching Hysteresis
Light Source
Wave Length
Polarization Filter
Service Life (T = +25 °C)
Laser Class (EN 60825-1)
Max. Ambient Light
Opening Angle
Light Spot Diameter
Two-Lens Optic
Electrical Data
> 2500 µm
< 15 %
Laser (red)
655 nm
yes
100000 h
2
10000 Lux
0,6 °
see Table 1
yes
Supply Voltage
10...30 V DC
Switching Frequency
3 kHz
Current Consumption (Ub = 24 V)
Response Time
Off-Delay
Temperature Drift
Range: 15 m
Smallest recognizable part: 2,5 mm
Switching frequency: 3 kHz
Time delay
RQ100BA
Temperature Range
Switching Output Voltage Drop
PNP Switching Output/Switching Current
Short Circuit Protection
Reverse Polarity Protection
Protection Class
Mechanical Data
< 30 mA
166 µs
5 ms
< 10 %
-10...60 °C
< 2,5 V
200 mA
yes
yes
III
Adjustment
Potentiometer
Full Encapsulation
yes
Housing Material
Degree of Protection
Connection
Plastic
IP67
M12 × 1; 4-pin
PNP NO/NC antivalent
Connection Diagram No.
Control Panel No.
Suitable Connection Technology No.
Suitable Mounting Technology No.
A reflector must be used in combination with these
sensors. They can be installed in all kinds of industrial
environments thanks to ample functional reserve. Even
reflective objects can be reliably recognized through
the use of polarized light.
Photoelectronic Sensors
101
M6
2
360
1 = Transmitter Diode
2 = Receiver Diode
Screw M4 = 1 Nm
All dimensions in mm (1 mm = 0.03937 Inch)
101
Legend
(NO)
(NC)
(NO)
(NC)
Power over Ethernet
Safety Input
Safety Output
Signal Output
Complementary Products
PNP-NPN Converter BG2V1P-N-2M
Protection Housing Set ZSM-NN-02
Protection Housing ZSV-0x-01
Reflector, Reflex Foil
Ctrl. Panel
M6
not connected
Test Input
Test Input inverted
Trigger Input
Analog Output
Ground for the Analog Output
Block Discharge
Valve Output
Valve Control Output +
Valve Control Output 0 V
Synchronization
Receiver-Line
Emitter-Line
Grounding
Switching Distance Reduction
Ethernet Receive Path
Ethernet Send Path
Interfaces-Bus A(+)/B(–)
Emitted Light disengageable
Magnet activation
Input confirmation
Contactor Monitoring
Table 1
Working Distance
0,2 m
Light Spot Diameter
5 mm
30
11
5m
35 mm
10 m
70 mm
Reflector type, mounting distance
RQ100BA
0,08...15 m RR25_M
0,15...7 m
RQ84BA
0,08...10 m RR21_M
0,1...3,5 m
RE9538BA
0,15...4,5 m ZRME01B01
RR50_A
0,08...10 m ZRMR02K01
RR84BA
RE6151BM
RE6040BA
RE8222BA
RR34_M
05 = Switching Distance Adjuster
11 = ON-Delay/OFF-Delay Adjuster
30 = Switching Status/Contamination Warning
Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White
Pink
Green Yellow
Feasible reflector distance
RE18040BA
05
Wire Colors according to
DIN IEC 757
RE3220BM
RE6210BM
0,1...12 m RR25KP
0,08...12 m ZRAE02B01
0,1...10 m ZRME03B01
0,08...10 m ZRMS02_01
0,08...8 m RF505
0,1...6 m RF508
0,1...6 m RF258
0,15...5,5 m ZRDF__K01
0,1...4 m
0,08...6 m
0,1...2 m
0,15...8 m
0,08...2,5 m
0,1...3 m
0,2...3 m
0,2...3 m
0,2...2,5 m
0,1...11 m
Specifications are subject to change without notice
Supply Voltage +
Supply Voltage 0 V
Supply Voltage (AC Voltage)
Switching Output
Switching Output
Contamination/Error Output
Contamination/Error Output
Input (analog or digital)
Teach Input
Time Delay (activation)
Shielding
Interface Receive Path
Interface Send Path
Ready
Ground
Clock
Output/Input programmable
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement