- No category
advertisement
Operating instructions
Lumax
www.bron-kobold.com
- 1 -
Operating instructions
Lumax
Ballast units EB 2x20/40
Light banks
EB 4x20/40
SB 12/22
Before use
Please read all the information contained in these operating instructions carefully.
They contain important details on the use, safety and maintenance of the lighting equipment. Keep these operating instructions in a safe place and pass them on to further users if necessary.
Observe the safety instructions.
Contents
General safety instructions ................................................................................. 2
Attention: Read before starting up ..................................................................... 3
1. Starting up......................................................................................................... 4
2. Power regulation .............................................................................................. 4
3. Installing or replacing tubes............................................................................ 4
4. Controls and displays ballast units ................................................................ 5
5. Technical data ballast units............................................................................. 7
6. Controls light banks ......................................................................................... 8
7. Technical data light banks............................................................................. 10
8. Replacement parts and accessories............................................................. 11
- 2 -
General safety instructions
When using your lighting equipment, basic safety precautions should always be followed including the following:
1. Read and understand all instructions before using.
2. Close supervision is necessary when any lamp is used by or near children. Do not leave lamp unattended while in use.
3. Care must be taken, as burns can occur from touching hot parts.
4. Do not operate lamp with damaged cable or if the lamp has been dropped or damaged – until it has been examined by a qualified serviceperson.
5. Position the cable so that it will not be tripped over, pulled, or make contact with hot surfaces.
6. If an extension cable is necessary, a cable with a current rating at least equal to that of the appliance should be used. Cables rated for less amperage than the appliance may overheat.
7. To reduce the risk of electric shock, never open this unit: take it to a qualified serviceperson when service or repair work is required. Incorrect reassembly can cause electric shock when the equipment is subsequently used.
8. The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire, electric shock, or injury to persons.
9. Always unplug ballast unit and lamp before cleaning or servicing and when not in use. Never jerk cable to pull plug from socket. Grasp plug and pull to disconnect.
10. Lumax ballast units and light banks are not compatible with products of other manufacturers. Lumax light banks or ballast units must only be used with
kobold products.
- 3 -
Attention: Read before starting up
-
For safety reasons the ballast units EB 2x20/40 und 2x20/40 may only be operated with an earthed mains (AC-line) plug.
-
These appliances are designed for use indoors and out. Though they have to be kept dry.
-
To reduce the risk of electric shock, do not immerse the ballast units and light banks in water or other liquids.
-
Before replacing fuses or fluorescent tubes, disconnect the ballast unit from power supply.
-
The equipment is not suitable for use in explosion-hazard areas.
- 4 -
Equip the light bank with tubes.
Connect the kobold lamp cable to the light bank and the ballast unit.
Screw the mains cable onto the ballast unit. Ensure that the cap nuts are fixed tightly.
Connect the ballast unit to the earthed mains supply. The appliances are designed for mains voltages from 200 up to 240 V or from 100 up to 120 V
(version 120 V).
Set the switch lever for power selection to the corresponding position (SB 12,
SB 14: 20 W ; SB 22, SB 24: 40 W)
Turn the dimmer to the right as far as it will go (max.).
Switch on the mains switch (on/off); the tubes need a heat-up period of a few minutes (undimmed, i.e. on full power).
The required light output can be set (100 % - 30 % adjustment range) with the power regulator (dimmer). Please note that the colour temperature can change depending on which type of tubes are used.
3. Installing or replacing tubes
Never replace a lamp without first disconnecting the light bank from the ballast unit.
- 5 -
4. Controls and displays EB 2x20/40 / EB 4x20/40
1. Grip
3. Mains cable socket
5. Mains switch (on/off) with monitoring lamp
- 6 -
5 6 7 1
3 4 2
- 7 -
5. Technical data ballast units
Lumax EB 2x 20/40
Article no.:
Mains voltage:
Mains frequency:
230 V version
742-0420
200-240 V AC
50 Hz – 60 Hz
120 V version
742-0310
100-120 V
50 Hz – 60 Hz
Output: 100 VA 130 VA
Nominal capacity: 2x20 W / 40 W switchable 2x20 W / 40 W switchable
Safety class: I I
Dimensions:
Weight:
Power variation:
503x88x62 mm
1.3 kg
100 % - 30 %
503x88x62 mm
1,4 kg
100 % - 30 %
Lumax EB 4x 20/40
Article no.:
Mains voltage:
230 V version
742-0220
200-240 V AC
120 V version
742-0120
100-120 V
Mains frequency:
Output:
50 Hz – 60 Hz
200 VA
50 Hz – 60 Hz
260 VA
Nominal capacity: 4x20 W / 40 W switchable 4x20 W / 40 W switchable
Safety class:
Dimensions:
Weight:
Power variation:
I
503x132x62 mm
1.8 kg
100 % - 30 %
I
503x132x62 mm
1,9 kg
100 % - 30 %.
6. Operation of kobold equipment with motor-generators
Kobold equipment is basically suitable for operation with motor-generators provided that the supply voltage remains within the tolerance limits of 200-264V or 95-135V respectively under all load conditions (including capacitive load). Experience shows that this usually requires electronically stabilized motor-generators.
- 8 -
7.
Controls:
Light banks Lumax SB12 / SB 22 / SB 14 / SB 24
1. Housing
2. Barn door
3. Cable stub for connecting lamp cable
4. Velcro locking for barn door
5. Velcro fastening for light grid
6. Safety rope for light grid
7. Stand adapter plate with ball joint
8. Safety loop for ceiling installation
9. Eye for wall installation
10. Retaining clips for fluorescent tubes with 26 mm and 38 mm ∅
11. Plug-in contacts for fluorescent tubes
12. Fluorescent tube
- 9 -
- 10 -
8. Technical data light banks
Lumax SB 12
Article no.:
Dimensions:
Weight:
Lamp cable:
Tubes:
Photometric:
Lumax SB 22
Article no.:
Dimensions:
Weight:
Lamp cable:
Tubes:
Photometric:
Lumax SB 14
Article no.:
Dimensions:
Weight:
Lamp cable:
Tubes:
Photometric:
Lumax SB 24
Article no.:
Dimensions:
Weight:
Lamp cable:
Tubes:
Photometric:
381-1012
700 x 193 x 87 mm without adapter plate
1.6 kg tubes incl., without adapter plate
3 m (removable) alternatively 26 mm or 38 mm
320 lx at 2 m
381-1022
1310 x 193 x 87 mm without adapter plate
3.2 kg tubes incl., without adapter plate
3 m (removable) alternatively 26 mm or 38 mm
750 lx at 2 m
381-1014
700 x 321 x 87 mm without adapter plate
2.7 kg tubes incl., without adapter plate
3 m (removable) alternatively 26 mm or 38 mm
320 lx at 2 m
381-1024
1310 x 321 x 87 mm without adapter plate
4.3 kg tubes incl., without adapter plate
3 m (removable) alternatively 26 mm or 38 mm
750 lx at 2 m
- 11 -
Art. no. 742-0715
Art. no. 683-1075
Art. no. 683-1135
Art. no. 673-1075
Art. no. 673-1135
Art. no. 033-0117
Art. no. 033-0103
Art. no. 033-0118
Art. no. 033-0104
Art. no. 033-0114
Art. no. 033-0102
Art. no. 033-0116
Art. no. 033-0101
Art. no. 817-0810
9. Replacement parts and accessories
Art. no. 742-0719 Lamp cable, 3 m, for SB 12 and SB 14
Lamp cable, 3 m, for SB 22 and SB 24
Daylight fluorescent tubes 20 W, 5800 K, with safety sheath, for SB 12 and SB14
Daylight fluorescent tubes 40 W, 5800 K, with safety sheath, for SB 22 and SB24
Artificial light fluorescent tubes 20 W, 3400 K, with safety sheath, for SB 12 and SB14
Artificial light fluorescent tubes 40 W, 3400 K, with safety sheath, for SB 22 and SB24
Light grid for SB 12, black
Light grid for SB 12, silver
Light grid for SB 22, black
Light grid for SB 22, silver
Light grid for SB 14, black
Light grid for SB 14, silver
Light grid for SB 24, black
Light grid for SB 24, silver
Adapter plate with 16 mm socket and mount
- 12 -
Bron Elektronik AG
Schweiz
- 13 -
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project