The ADE7880 is a high accuracy, 3-phase electrical energy measurement IC with serial interfaces and three flexible pulse outputs. The ADE7880 device incorporates second-order sigma-delta (Σ-Δ) analog-to-digital converters (ADCs), a digital integrator, reference circuitry, and all of the signal processing required to perform the total (fundamental and harmonic) active and apparent energy measurements, rms calculations, and fundamental-only active and reactive energy measurements.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
56
Evaluation Board User Guide UG-356 One Technology Way • P.O. Box 9106 • Norwood, MA 02062-9106, U.S.A. • Tel: 781.329.4700 • Fax: 781.461.3113 • www.analog.com Evaluating the ADE7880 Energy Metering IC FEATURES Evaluation board designed to be used with accompanying software to implement a fully functional 3-phase energy meter Easy connection of external transducers via screw terminals Easy modification of signal conditioning components using PCB sockets LED indicators on the CF1, CF2, CF3, IRQ0, and IRQ1 logic outputs Optically isolated metering components and USB-based communication with a PC External voltage reference option available for on-chip reference evaluation PC COM port-based firmware updates GENERAL DESCRIPTION The ADE7880 is a high accuracy, 3-phase electrical energy measurement IC with serial interfaces and three flexible pulse outputs. The ADE7880 device incorporates second-order sigma-delta (Σ-Δ) analog-to-digital converters (ADCs), a digital integrator, reference circuitry, and all of the signal processing required to perform the total (fundamental and harmonic) active and apparent energy measurements, rms calculations, and fundamental-only active and reactive energy measurements. In addition, the ADE7880 computes the rms of harmonics on the phase and neutral currents and on the phase voltages, PLEASE SEE THE LAST PAGE FOR AN IMPORTANT WARNING AND LEGAL TERMS AND CONDITIONS. together with the active, reactive, and apparent powers, the power factor and harmonic distortion on each harmonic for all phases. Total harmonic distortion (THD) is computed for all currents and voltages. This user guide describes the ADE7880 evaluation kit hardware, firmware, and software functionality. The evaluation board contains an ADE7880 and an LPC2368 microcontroller (from NXP Semiconductors). The ADE7880 and its associated metering components are optically isolated from the microcontroller. The microcontroller communicates with the PC using a USB interface. The ADE7880 evaluation board and this user guide, together with the ADE7880 data sheet, provide a complete evaluation platform for the ADE7880. The evaluation board has been designed so that the ADE7880 can be evaluated as an energy meter. Using appropriate current transducers, the evaluation board can be connected to a test bench or high voltage (240 V rms) test circuit. On-board resistor divider networks provide the attenuation for the line voltages. This user guide describes how the current transducers should be connected for the best performance. The evaluation board requires two power supplies, one external supply of 3.3 V and one supply provided by connecting a USB cable between a PC and the board. Appropriate current transducers are also required. Rev. 0 | Page 1 of 56 UG-356 Evaluation Board User Guide TABLE OF CONTENTS Features .............................................................................................. 1 PSM3 Mode ................................................................................. 24 General Description ......................................................................... 1 Revision History ............................................................................... 2 Managing the Communication Protocol Between the Microcontroller and the ADE7880 .............................................. 25 Evaluation Board Connection Diagram ........................................ 3 Acquiring HSDC Data Continuously ...................................... 28 Evaluation Board Hardware ............................................................ 4 Starting the ADE7880 DSP ....................................................... 30 Power Supplies .............................................................................. 4 Stopping the ADE7880 DSP ..................................................... 30 Analog Inputs (P1 to P4 and P5 to P8)...................................... 4 Upgrading Microcontroller Firmware ......................................... 35 Setting Up the Evaluation Board as an Energy Meter ............. 9 Control Registers Data File ....................................................... 36 Evaluation Board Software ............................................................ 12 Evaluation Board Schematics and Layout ................................... 38 Installing and Uninstalling the ADE7880 Software ............... 12 Schematic..................................................................................... 38 Front Panel .................................................................................. 12 Layout .......................................................................................... 51 PSM0 Mode—Normal Power Mode ........................................ 13 Ordering Information .................................................................... 54 PSM1 Mode ................................................................................. 22 Bill of Materials ........................................................................... 54 PSM2 Mode ................................................................................. 23 REVISION HISTORY 2/12—Revision 0: Initial Version Rev. 0 | Page 2 of 56 Evaluation Board User Guide UG-356 EVALUATION BOARD CONNECTION DIAGRAM VDD P9 GND IBN IBP IAN IAP P2 VDD2 GND2 P1 P10 MCU_VDD MCU_GND P12 P3 ICP ICN USB PORT LPC2368 ADE7880 FILTER NETWORK DIGITAL ISOLATORS INP P13 INN P15 OPTIONAL EXTERNAL CLOCK INPUT OPTIONAL EXTERNAL ADR280 1.2V REFERENCE CONNECTOR TO PC COM PORT FILTER NETWORK AND ATTENUATION P5 P6 VN GND VCP P7 GND VBP JTAG INTERFACE J2 P8 GND VAP GND Figure 1. Rev. 0 | Page 3 of 56 J3 CF3 J4 CF2 CF1 10385-001 P4 UG-356 Evaluation Board User Guide EVALUATION BOARD HARDWARE The evaluation board has two power domains: one domain supplies the microcontroller and one side of the isocouplers and one domain supplies the other side of the isocouplers and the ADE7880. The ground of the microcontroller’s power domain is connected to the ground of the PC through the USB cable. The ground of the ADE7880 power domain is determined by the ground of the phase voltages, VAP, VBP, VCP, and VN, and must be different from the ground of the microcontroller’s power domain. The microcontroller 3.3 V supply is provided by the PC through the USB cable. Alternatively, if Jumper JP24 is connected between Pin 1 and Pin 2, the 3.3 V supply can be provided at the P12 connector. The ADE7880 3.3 V supply is provided at the P9 connector. Ensure that Jumper JP11 is connected between Pin 1 and Pin 2 to ensure the same 3.3 V supply from the ADE7880 is also provided at the isocouplers. The R1 and R2 resistors are the burden resistors and, by default, they are not populated. They can also be disabled using the JP1A and JP2A jumpers. The R9/C9 and R10/C10 RC networks are used in conjunction with Rogowski coils. They can be disabled using the JP3A and JP4A jumpers. The R17/C17 and R18/C18 RC networks are the antialiasing filters. The default corner frequency of these low-pass filters is 72 kHz (1 kΩ/2.2 nF). These filters can easily be adjusted by replacing the components on the evaluation board. All the other current channels (that is, Phase B, Phase C, and the neutral current) have an identical input structure. Using a Current Transformer as the Current Sensor Figure 3 shows how a current transformer can be used as a current sensor in one phase of a 3-phase, 4-wire distribution system (Phase A). The other two phases and the neutral current require similar connections. ANALOG INPUTS (P1 TO P4 AND P5 TO P8) Current and voltage signals are connected at the screw terminals, P1 to P4 and P5 to P8, respectively. All analog input signals are filtered using the on-board antialiasing filters before the signals are connected to the ADE7880. The components used on the board are the recommended values to be used with the ADE7880. IMAX = 6 ARMS CT 1:2000 P1 JP3A JP5A R9 R17 100Ω 1kΩ JP1A R1 50Ω C9 2.2nF C17 2.2nF JP2A R2 50Ω C10 2.2nF C18 2.2nF Current Sense Inputs (P1, P2, P3, and P4) R10 R18 The ADE7880 measures three phase currents and the neutral current. Current transformers or Rogowski coils can be used to sense the currents. These sensors cannot be mixed together for the phase currents sensing, but the neutral current may be sensed using a different sensor. The ADE7880 contains different internal PGA gains on phase currents and on the neutral current; therefore, sensors with different ratios can be used. The only requirement is to have the same scale signals at the PGA outputs; otherwise, the mismatch functionality of the ADE7880 is compromised (see the ADE7880 data sheet for more details about neutral current mismatch). Figure 2 shows the structure used for the Phase A current; the sensor outputs are connected to the P1 connector. 100Ω 1kΩ JP4A JP6A P1 JP3A JP5A R9 R17 100Ω 1kΩ JP1A R1 C9 2.2nF C17 2.2nF JP2A R2 C10 2.2nF C18 2.2nF IAP ADE7880 R1 = R2 = 1/2 × 0.5/√2 × N/IFS where: 0.5/√2 is the rms value of the full-scale voltage accepted at the ADC input. N is the input-to-output ratio of the current transformer. Figure 3 shows an example for N = 2000. IFS is the maximum rms current to be measured. The JP1A and JP2A jumpers should be opened if R1 and R2 are used. The antialiasing filters should be enabled by opening the J5A and J6A jumpers (see Figure 3). 1kΩ JP4A JP6A IAN 10385-002 100Ω IAN The R1 and R2 burden resistors must be defined as functions of the current transformer ratio and the maximum current of the system, using the following formula: IAN R18 ADE7880 Figure 3. Example of a Current Transformer Connection IAP R10 IAP 10385-003 POWER SUPPLIES Figure 2. Phase A Current Input Structure on the Evaluation Board Rev. 0 | Page 4 of 56 Evaluation Board User Guide UG-356 For this particular example, burden resistors of 50 Ω signify an input current of 7.05 A rms at the ADE7880 ADC full-scale input (0.5 V). In addition, the PGA gains for the current channel must be set at 1. For more information about setting PGA gains, see the ADE7880 data sheet. The evaluation software allows the user to configure the current channel gain. R17 100Ω 1kΩ JP1A R1 C9 2.2nF JP2A R2 C10 2.2nF IAP C17 2.2nF C18 2.2nF R10 R18 100Ω 1kΩ JP4A JP6A ADE7880 IAN Figure 5 shows a typical connection of the Phase A voltage inputs; the resistor divider is enabled by opening the JP7A jumper, closing JP9A and connecting JP8A to AGND (Pin 1). The antialiasing filter on the VN data path is enabled by opening the JP7N jumper. The VN analog input is connected to AGND via the R25/C25 antialiasing filter using the P5 connector. The attenuation networks can be easily modified by the user to accommodate any input level. However, the value of R32 (1 kΩ), should be modified only together with the corresponding resistors in the current channel (R17 and R18 on the Phase A current data path). R26 1Ω JP7A VN JP8A P5 R25 VN A COM B 1kΩ 2.2nF VN JP7N 10385-005 Voltage Sense Inputs (P5, P6, P7, and P8 Connectors) The voltage input connections on the ADE7880 evaluation board can be directly connected to the line voltage sources. The line voltages are attenuated using a simple resistor divider network before they are supplied to the ADE7880. The attenuation network on the voltage channels is designed so that the 3 dB corner frequency of the network matches that of the antialiasing filters in the current channel inputs. This prevents the occurrence of large energy errors at low power factors. ADE7880 2.2nF R32 JP9A 1kΩ 1kΩ C28 VAP A COM B R29 C25 VAP P8 PHASE A Figure 4 shows how a Rogowski coil can be used as a current sensor in one phase of a 3-phase, 4-wire distribution system (Phase A). The other two phases and the neutral current require identical connections. The Rogowski coil does not require any burden resistors; therefore, R1 and R2 should not be populated. The antialiasing filters should be enabled by opening the JP5A and JP6A jumpers. To account for the high frequency noise introduced by the coil, an additional antialiasing filter must be introduced by opening the JP3A and JP4A jumpers. Then, to compensate for the 20 dB/dec gain introduced by the di/dt sensor, the integrator of the ADE7880 must be enabled by setting Bit 0 (INTEN) of the CONFIG register. The integrator has a −20 dB/dec attenuation and a phase shift of approximately −90° and, when combined with the di/dt sensor, results in a magnitude and phase response with a flat gain over the frequency band of interest. R9 Figure 4. Example of a Rogowski Coil Connection NEUTRAL Using a Rogowski Coil as the Current Sensor JP5A 10385-004 ROGOWSKI COIL P1 JP3A A COM B The secondary current of the transformer is converted to a voltage by using a burden resistor across the secondary winding outputs. Care should be taken when using a current transformer as the current sensor. If the secondary is left open (that is, no burden is connected), a large voltage may be present at the secondary outputs. This can cause an electric shock hazard and potentially damage electronic components. Figure 5. Phase A Voltage Input Structure on the Evaluation Board The maximum signal level permissible at the VAP, VBP, and VCP pins of the ADE7880 is 0.5 V peak. Although the ADE7880 analog inputs can withstand ±2 V without risk of permanent damage, the signal range should not exceed ±0.5 V with respect to AGND for a specified operation. Rev. 0 | Page 5 of 56 UG-356 Evaluation Board User Guide Table 1. Recommended Settings for Evaluation Board Connectors Jumper JP1A Option Closed Open (default) JP1B Closed Open (default) JP1C Closed Open (default) JP1N Closed Open (default) JP2A Closed Open (default) JP2B Closed Open (default) JP2C Closed Open (default) JP2N Closed Open (default) JP3A JP3B JP3C JP3N JP4A JP4B JP4C JP4N JP5A JP5B Closed (default) Open Closed (default) Open Closed (default) Open Closed (default) Open Closed (default) Open Closed (default) Open Closed (default) Open Closed (default) Open Closed Open (default) Closed Open (default) Description Connects Pin 1 of the Channel IA pin connector, P1, to AGND. Use this configuration in conjunction with JP3A and JP5A to short the IAP pin of the ADE7880 to AGND. Pin 1 of the Channel IA pin connector, P1, is left floating. Use this configuration in normal operation to drive IAP with analog signal. Connects Pin 1 of the Channel IB pin connector, P2, to AGND. Use this configuration in conjunction with JP3B and JP5B to short the IBP pin of the ADE7880 to AGND. Pin 1 of the Channel IB pin connector, P2, is left floating. Use this configuration in normal operation to drive IBP with analog signal. Connects Pin 1 of the Channel IC pin connector, P3, to AGND. Use this configuration in conjunction with JP3C and JP5C to short the ICP pin of the ADE7880 to AGND. Pin 1 of the Channel IC pin connector, P3, is left floating. Use this configuration in normal operation to drive ICP with analog signal. Connects Pin 1 of the Channel IN pin connector, P4, to AGND. Use this configuration in conjunction with JP3N and JP5N to short the INP pin of the ADE7880 to AGND. Pin 1 of the Channel IN pin connector, P4, is left floating. Use this configuration in normal operation to drive INP with analog signal. Connects Pin 2 of the Channel IA pin connector, P1, to AGND. Use this configuration in conjunction with JP4A and JP6A to short the IAN pin of the ADE7880 to AGND. Pin 2 of the Channel IA pin connector, P1, is left floating. Use this configuration in normal operation when driving a differential input to IAN. Connects Pin 2 of the Channel IB pin connector, P2, to AGND. Use this configuration in conjunction with JP4B and JP6B to short the IBN pin of the ADE7880 to AGND. Pin 2 of the Channel IB pin connector, P2, is left floating. Use this configuration in normal operation when driving a differential input to IBN. Connects Pin 2 of the Channel IC pin connector, P3, to AGND. Use this configuration in conjunction with JP4C and JP6C to short the ICN pin of the ADE7880 to AGND. Pin 2 of the Channel IC pin connector, P3, is left floating. Use this configuration in normal operation when driving a differential input to ICN. Connects Pin 2 of the Channel IN pin connector, P4, to AGND. Use this configuration in conjunction with JP4N and JP6N to short the INN pin of the ADE7880 to AGND. Pin 2 of the Channel IBN pin connector, P2, is left floating. Use this configuration in normal operation when driving a differential input to IBN. Disables the phase compensation network (composed by R9 and C9) in the IAP data path. Enables the phase compensation network (composed by R9 and C9) in the IAP data path. Disables the phase compensation network (composed by R11 and C11) in the IBP data path. Enables the phase compensation network (composed by R11 and C11) in the IBP data path. Disables the phase compensation network (composed by R13 and C13) in the ICP data path. Enables the phase compensation network (composed by R13 and C13) in the ICP data path. Disables the phase compensation network (composed by R15 and C15) in the INP data path. Enables the phase compensation network (composed by R15 and C15) in the INP data path. Disables the phase compensation network (composed by R10 and C10) in the IAN data path. Enables the phase compensation network (composed by R10 and C10) in the IAN data path. Disables the phase compensation network (composed by R12 and C12) in the IBN data path. Enables the phase compensation network (composed by R12 and C12) in the IBN data path. Disables the phase compensation network (composed by R14 and C14) in the ICN data path. Enables the phase compensation network (composed by R14 and C14) in the ICN data path. Disables the phase compensation network (composed by R16 and C16) in the INN data path. Enables the phase compensation network (composed by R16 and C16) in the INN data path. Disables the phase antialiasing filter (composed by R17 and C17) in the IAP data path. Enables the phase antialiasing filter (composed by R17 and C17) in the IAP data path. Disables the phase antialiasing filter (composed by R19 and C19) in the IBP data path. Enables the phase antialiasing filter (composed by R19 and C19) in the IBP data path. Rev. 0 | Page 6 of 56 Evaluation Board User Guide Jumper JP5C JP5N JP6A JP6B JP6C JP6N JP7A Option Closed Open (default) Closed Open (default) Closed Open (default) Closed Open (default) Closed Open (default) Closed Open (default) Closed between Pin 2 and Pin 1 Closed between Pin 2 and Pin 3 Unconnected (default) JP7B Closed between Pin 2 and Pin 1 Closed between Pin 2 and Pin 3 Unconnected (default) JP7C Closed between Pin 2 and Pin 1 Closed between Pin 2 and Pin 3 Unconnected (default) JP7N Closed between Pin 2 and Pin 1 Closed between Pin 2 and Pin 3 Unconnected (default) JP8A Soldered between Pin 2 and Pin 1 (default) Soldered between Pin 2 and Pin 3 Soldered between Pin 2 and Pin 1 (default) Soldered between Pin 2 and Pin 3 Soldered between Pin 2 and Pin 1 (default) Soldered between Pin 2 and Pin 3 JP8B JP8C UG-356 Description Disables the phase antialiasing filter (composed by R21 and C21) in the ICP data path. Enables the phase antialiasing filter (composed by R21 and C21) in the ICP data path. Disables the phase antialiasing filter (composed by R23 and C23) in the INP data path. Enables the phase antialiasing filter (composed by R23 and C23) in the INP data path. Disables the phase antialiasing filter (composed by R18 and C18) in the IAN data path. Enables the phase antialiasing filter (composed by R18 and C18) in the IAN data path. Disables the phase antialiasing filter (composed by R20 and C20) in the IBN data path. Enables the phase antialiasing filter (composed by R20 and C20) in the IBN data path. Disables the phase antialiasing filter (composed by R22 and C22) in the ICN data path. Enables the phase antialiasing filter (composed by R22 and C22) in the ICN data path. Disables the phase antialiasing filter (composed by R24 and C24) in the INN data path. Enables the phase antialiasing filter (composed by R24 and C24) in the INN data path. Disables the resistor divider (composed by R26, R29, and R32) when JP9A is open. Use this configuration when using a low voltage signal source in the VAP data path. Connects the VAP pin of the ADE7880 to AGND. Use this configuration when no signal source is desired in the VAP data path. Enables the resistor divider (composed by R26, R29, and R32) when JP9A is closed. Use this configuration when using a high voltage signal source in the VAP data path in 3-phase, 4-wire and 3-phase 3-wire configurations. Disables the resistor divider (composed by R27, R30, and R33) when JP9B is open. Use this configuration when using a low voltage signal source in the VBP data path. Connects the VBP pin of the ADE7880 to AGND. Use this configuration when no signal source is desired in the VBP data path, such as 3-phase, 3-wire configuration. Enables the resistor divider (composed by R27, R30, and R33) when JP9B is closed. Use this configuration when using a high voltage signal source in the VBP data path in 3-phase, 4-wire configuration. Disables the resistor divider (composed by R28, R31, and R34) when JP9C is open. Use this configuration when using a low voltage signal source in the VCP data path. Connects the VCP pin of the ADE7880 to AGND. Use this configuration when no signal source is desired in the VCP data path. Enables the resistor divider (composed by R28, R31, and R34) when JP9C is closed. Use this configuration when using a high voltage signal source in the VCP data path in 3-phase 4-wire and 3-phase, 3-wire configurations. Disables the antialiasing filter (composed by R25 and C25) in the VN data path. Use this configuration when normal single ended signals are connected to the ADE7880 voltage channels. Connects the VN pin of the ADE7880 to AGND. Use this configuration when the ADE7880 voltage channels are connected to AGND. Enables the antialiasing filter in the VN data path. Use this configuration when the ADE7880 voltage channels are differential, in 3-phase, 4-wire and 3-phase, 3-wire configurations. Connects C28 to AGND. Use this configuration when the ADE7880 voltage channels are differential, in 3-phase, 4-wire and 3-phase, 3-wire configurations. Connects C28 to VN. Use this configuration, with JP7N connected between Pin 2 and Pin 3, when the ADE7880 voltage channels are single-ended. Connects C27 to AGND. Use this configuration when the ADE7880 voltage channels are differential, in 3-phase, 4-wire and 3-phase, 3-wire configurations. Connects C27 to VN. Use this configuration, with JP7N connected between Pin 2 and Pin 3, when the ADE7880 voltage channels are single-ended. Connects C25 to AGND. Use this configuration when ADE7880 voltage channels are differential, in 3-phase, 4-wire and 3-phase, 3-wire configurations. Connects C25 to VN. Use this configuration, with JP7N connected between Pin 2 and Pin 3, when the ADE7880 voltage channels are single-ended. Rev. 0 | Page 7 of 56 UG-356 Jumper JP9A Evaluation Board User Guide Option Closed (default) Open JP9B Closed (default) Open JP9C Closed (default) Open JP10 Soldered between Pin 2 and Pin 1 (default) Soldered between Pin 2 and Pin 3 JP11 Closed between Pin 2 and Pin 1 (default) Closed between Pin 2 and Pin 3 Closed JP12 Open (default) JP21 Closed Open (default) JP24 Closed between Pin 2 and Pin 1 Closed between Pin 2 and Pin 3 (default) JP31, JP32, JP33, JP34 Closed between Pin 2 and Pin 1 Closed between Pin 2 and Pin 3 (default) Description Enables the resistor divider (composed by R26, R29, and R32) when JP7A is unconnected. Use this configuration when using a high voltage signal source in the VAP data path, in 3-phase, 4-wire and 3-phase, 3-wire configurations. Disables the resistor divider (composed by R26, R29, and R32) when JP7A is closed between Pin 1 and Pin 2. Use this configuration when using a low voltage signal source in the VAP data path. Enables the resistor divider (composed by R27, R30, and R33) when JP7B is unconnected. Use this configuration when using a high voltage signal source in the VBP data path in 3-phase, 4-wire and 3-phase, 3-wire configurations. Disables the resistor divider (composed by R27, R30, and R33) when JP7B is closed between Pin 1 and Pin 2. Use this configuration when using a low voltage signal source in the VBP data path. Enables the resistor divider (composed by R28, R31, and R34) when JP7C is unconnected. Use this configuration when using a high voltage signal source in the VCP data path in 3 phase, 4 wire and 3-phase, 3-wire configurations. Disables the resistor divider (composed by R28, R31, and R34) when JP7C is closed between Pin 1 and Pin 2. Use this configuration when using a low voltage signal source in the VCP data path. Connects the on-board 16.384 MHz crystal, Y1, to the CLKIN pin of the ADE7880. Use this configuration when Crystal Y1 is used as the clock source for the ADE7880. Disconnects the on-board 16.384 MHz crystal, Y1, from the CLKIN pin of the ADE7880. Use this configuration when an external clock is used. This clock can be connected to the EXT_CLKIN connector. Connects the supply of the secondary side of the isocouplers (VDD2) to VDD, the supply of the ADE7880. Connects the supply of the secondary side of the isocouplers (VDD2) to a 3.3 V supply provided at the P10 connector. Connects the ADR280 voltage reference to the REFIN/OUT pin of the ADE7880. Use this configuration when the ADE7880 is configured to use an external reference. Disconnects the ADR280 voltage reference from the REFIN/OUT pin of the ADE7880. Use this configuration in normal operation when the ADE7880 is configured to use the internal reference. Signals the NXP LPC2368 microcontroller to declare all I/O pins as outputs. Use this configuration when another microcontroller manages the ADE7880 through the P17 socket. Disables the option to use another microcontroller to manage the ADE7880 through the P17 socket. Use this configuration in normal operation to allow the NXP LPC2368 microcontroller to manage the ADE7880. Selects an external 3.3 V power supply provided at P12 connector to power the domain that includes the NXP LPC2368 and one side of the isocouplers. Use this configuration if USB provided power supply is not desired. Selects the USB provided power supply to power the domain that includes the NXP LPC2368 and one side of the isocouplers. Use this configuration in normal operation to provide power to the NXP LPC2368 and one side of the isocouplers from the PC. When I2C communication between the NXP LPC2368 and the ADE7880 is used, the HSDC port of the ADE7880 is also enabled and the SPI port of the ADE7880 is disabled. Use this configuration when I2C communication is selected. When SPI communication between the NXP LPC2368 and the ADE7880 is used, the I2C and HSDC ports of the ADE7880 are disabled. Use this configuration when SPI communication is selected. Rev. 0 | Page 8 of 56 Evaluation Board User Guide UG-356 Activating Serial Communication Between the ADE7880 and the NXP LPC2368 SETTING UP THE EVALUATION BOARD AS AN ENERGY METER Figure 6 shows a typical setup for the ADE7880 evaluation board. In this example, an energy meter for a 3-phase, 4-wire, wye distribution system is shown. Current transformers are used to sense the phase and neutral currents and are connected as shown in Figure 6. The line voltages are connected directly to the evaluation board as shown. Note that the state of all jumpers must match the states shown in Figure 6, equal to the default states in Table 1. The board is supplied from two different power supplies. One is supplied by the PC through the USB cable and is used for the NXP LPC2368 and one side of the isocouplers. The other is an external 3.3 V supply used for the ADE7880 domain and the other side of the isocouplers. Because the two domains are isolated to ensure that there is no electrical connection between the high voltage test circuit and the control circuit, the external power supply should have floating voltage outputs. Figure 7 shows a setup for the ADE7880 evaluation board as an energy meter for a 3-phase, 3-wire, delta distribution system. The Phase B voltage is used as a reference, and the VN pin of the ADE7880 is connected to it. The evaluation board is connected to the PC using a USB cable supplied with the board. When the evaluation board is connected to the PC, the enumeration process begins. The PC recognizes new hardware and asks to install the appropriate driver. The driver can be found in the VirCOM_Driver_XP folder on the CD for a Windows XP PC or in the VirCom_Driver_W7_64bit for a Windows 7 64-bit PC. After the driver is installed, the supplied evaluation software can be started. The Evaluation Board Software section describes the ADE7880 evaluation software in detail and how it can be installed and uninstalled. The ADE7880 evaluation board provides communication between the ADE7880 and the NXP LPC2368 that is set through the SPI ports. The JP31, JP32, JP33, and JP34 jumpers are closed between Pin 2 and Pin 3. The SPI port should be chosen as the active port in the ADE7880 control panel. Communication between the ADE7880 and the NXP LPC2368 is also possible using the I2C ports. To accomplish this, the JP31, JP32, JP33, and JP34 jumpers should be closed between Pin 2 and Pin 1. In this case, the I2C port should be chosen as the active port in the ADE7880 control panel (see Table 2). Note that the HSDC port of the ADE7880 also becomes available to communicate with the NXP LPC2368 in this case. Table 2. Jumper State to Activate SPI or I2C Communication Active Communication SPI (Default) I2C Jumpers JP31, JP32, JP33, JP34 Closed between Pin 2 and Pin 3 Closed between Pin 2 and Pin 1 Using the Evaluation Board with Another Microcontroller It is possible to manage the ADE7880 mounted on the evaluation board with a different microcontroller mounted on another board. The ADE7880 can be connected to this second board through one of two connectors: P11 or P17. P11 is placed on the same power domain as the ADE7880. P17 is placed on the power domain of the NXP LPC2368 and communicates with the ADE7880 through the isocouplers. If P11 is used, the USB cable should not be connected between the PC and the board to avoid supplying the power domain of the NXP LPC2368. If P17 is used, a conflict may arise with the NXP LPC2368 I/O ports. To avoid this conflict, close the JP21 jumper. This tells the NXP LPC2368 to set all of its I/O ports high to allow the other microcontroller to communicate with the ADE7880. After JP21 is closed, the S2 reset button should be pressed low to reset the NXP LPC2368. This is necessary because the state of JP21 is checked inside the NXP LPC2368 program only once after reset. Rev. 0 | Page 9 of 56 UG-356 Evaluation Board User Guide JP24 CLOSED BETWEEN PIN 2 AND PIN 3 VOLTAGE SOURCE JP11 CLOSED BETWEEN PIN 2 AND PIN 1 PHASE C AND PC VDD GND USB CABLE CONNECTED BETWEEN THE BOARD P9 PHASE B NEUTRAL PHASE A P1 IAP R1 IAP JP1 A , JP2 A = OPEN JP3 A , JP4 A = CLOSED R2 IAN IAN JP5 A , JP6 A = OPEN IBP JP1 B, JP2 B = OPEN P2 R3 IBP JP3 B, JP4 B = CLOSED R4 IBN IBN JP5 B, JP6 B = OPEN ICP JP1 C, JP2 C = OPEN P3 R5 ICP JP3 C, JP4 C = CLOSED R6 ICN ICN JP5 C, JP6 C = OPEN INP JP1 N , JP2 N = OPEN P4 R7 INP JP3 N , JP4 N = CLOSED R8 INN INN JP5 N , JP6 N = OPEN VAP JP7 A = UNCONNECTED P8 R26 VAP BETWEEN PIN 2 AND PIN 1 C28 R32 JP8 A = SOLDERED JP9 A = CLOSED P7 R27 VBP VBP JP7 B = UNCONNECTED BETWEEN PIN 2 AND PIN 1 C27 R33 JP8 B = SOLDERED JP9 B = CLOSED P6 R28 VCP VCP JP7 C = UNCONNECTED LOAD BETWEEN PIN 2 AND PIN 1 C26 R34 JP8 C = SOLDERED JP9 C = CLOSED P5 VN JP7 N = UNCONNECTED NEUTRAL Figure 6. Typical Setup for the ADE7880 Evaluation Board for 3-Phase, 4-Wire, Wye Distribution Systems Rev. 0 | Page 10 of 56 10385-006 R25 C25 VN Evaluation Board User Guide UG-356 JP24 CLOSED BETWEEN PIN 2 AND PIN 3 VOLTAGE SOURCE JP11 CLOSED BETWEEN PIN 2 AND PIN 1 PHASE C AND PC VDD GND USB CABLE CONNECTED BETWEEN THE BOARD P9 PHASE B PHASE A P1 IAP R1 IAP JP1 A , JP2 A = OPEN JP3 A , JP4 A = CLOSED R2 IAN IAN JP5 A , JP6 A = OPEN IBP JP1 B, JP2 B = OPEN P2 R3 IBP JP3 B, JP4 B = CLOSED R4 IBN IBN JP5 B, JP6 B = OPEN ICP JP1 C, JP2 C = OPEN P3 R5 ICP JP3 C, JP4 C = CLOSED R6 ICN ICN JP5 C, JP6 C = OPEN INP JP1 N , JP2 N = CLOSED P4 INP JP3 N , JP4 N = CLOSED INN INN JP5 N , JP6 N = CLOSED VAP JP7 A = UNCONNECTED P8 R26 VAP BETWEEN PIN 2 AND PIN 1 C28 R32 JP8 A = SOLDERED JP9 A = CLOSED P7 VBP VBP JP7B = CONNECTED BETWEEN PIN 2 AND PIN 3 JP8 B = SOLDERED BETWEEN PIN 2 AND PIN 1 JP9 B = CLOSED P6 R28 VCP VCP JP7 C = UNCONNECTED LOAD BETWEEN PIN 2 AND PIN 1 C26 R34 JP8 C = SOLDERED JP9 C = CLOSED P5 VN JP7 N = UNCONNECTED Figure 7. Typical Setup for the ADE7880 Evaluation Board for 3-Phase, 3-Wire, Delta Distribution Systems Rev. 0 | Page 11 of 56 10385-007 R25 C25 VN UG-356 Evaluation Board User Guide EVALUATION BOARD SOFTWARE The ADE7880 evaluation board is supported by Windows® based software that allows the user to access all the functionality of the ADE7880. The software communicates with the NXP LPC2368 microcontroller using the USB as a virtual COM port. The NXP LPC2368 communicates with the ADE7880 to process the requests that are sent from the PC. The serial communication between the microcontroller and the ADE7880 is selected using a switch in the LabVIEW software. By default, the SPI port is used. Note that the active serial port must first be set in the hardware. See the Activating Serial Communication Between the ADE7880 and the NXP LPC2368 section for details on how to set it up. INSTALLING AND UNINSTALLING THE ADE7880 SOFTWARE The main menu has only one choice, other than Exit, enabled, Find COM Port. Clicking it starts a process in which the PC tries to connect to the evaluation board using the port indicated in the Start menu. It uses the echo function of the communication protocol (see the Managing the Communication Protocol Between the Microcontroller and the ADE7880 section). It displays the port that matches the protocol and then sets it to 115,200 baud, eight data bits, no parity, no flow control, one stop bit. The ADE7880 software is supplied on one CD-ROM. It contains two projects: one that represents the NXP LPC2368 project and one LabVIEW™ based program that runs on the PC. The NXP LPC2368 project is already loaded into the processor, but the LabVIEW based program must be installed. 1. 2. To install the ADE7880 software, place the CD-ROM in the CD-ROM reader and double-click LabView_project\ installation_files\setup.exe. This launches the setup program that automatically installs all the software components, including the uninstall program, and creates the required directories. To launch the software, go to the Start/Programs/ ADE7880 Eval Software menu and click ADE7880 Eval Software. 1. 2. 3. Before installing a new version of the ADE7880 evaluation software, first uninstall the previous version. Select the Add/Remove Programs option in the Windows Control Panel. Select the program to uninstall and click the Add/Remove button. FRONT PANEL When the evaluation board software is launched, the Front Panel is opened. This panel contains three areas: the main menu at the left, the sub-menu at the right, and a box that displays the name of the communication port used by the PC to connect to the evaluation port, also at the right (see Figure 8). The COM port used to connect the PC to the evaluation board must be selected first. The program displays a list of the active COM ports, allowing you to select the correct part. To learn which COM port is used by the evaluation board, launch the Windows Device Manager (the devmgmt.msc file) in the Run window on the Windows Start menu. By default, the program offers the option of searching for the COM port. 10385-008 Both the ADE7880 evaluation software program and the LabVIEW run-time engine are easily uninstalled using the Add/ Remove Programs option in the Control Panel. Figure 8. Front Panel of the ADE7880 Software If the evaluation board is not connected, the port is displayed as XXXXX. In this case, the evaluation software is still accessible, but no communication can be established. Whether the search for the COM port is successful or not, the cursor is positioned at Please select from the following options in the main menu, Find COM Port is grayed out, and the other main menu options are enabled (see Figure 9). These options allow you to command the ADE7880 in either the PSM0 or PSM3 power mode. The other power modes, PSM1 and PSM2, are not available because they must be initialized in PSM0 before the ADE7880 can be used in PSM1 or PSM2. Rev. 0 | Page 12 of 56 10385-010 UG-356 10385-009 Evaluation Board User Guide Figure 9. Front Panel After the COM Port Is Identified Figure 10. Front Panel After the ADE7880 Enters PSM0 Mode PSM0 MODE—NORMAL POWER MODE Reset ADE7880 Enter PSM0 Mode When Reset ADE7880 is selected on the Front Panel, the RESET pin of the ADE7880 is kept low for 20 ms and then is set high. If the operation is correctly executed, the message, ADE7880 was reset successfully, is displayed, and you must click OK to continue. The only error that may occur during this operation is communication related; if this happens, the following message is displayed: The communication between PC and ADE7880 evaluation board or between LPC2368 and ADE7880 did not function correctly. There is no guarantee the reset of ADE7880 has been performed. When the evaluation board is powered up, the ADE7880 is in PSM3 sleep mode. When Enter PSM0 mode is selected, the microcontroller activates the PM0 and PM1 pins of the ADE7880 to switch it into PSM0 mode. It waits 50 ms for the circuit to power up and, if SPI communication is activated on the board, it executes three SPI write operations to Address 0xEBFF of the ADE7880 to activate the SPI port. If the operation is correctly executed or if I2C communication is used, the message Configuring LPC2368—ADE7880 communication was successful is displayed, and you must click OK to continue. The only error that may occur during this operation is communication related; if this happens, the following message is displayed: Configuring LPC2368— ADE7880 communication was not successful. Please check the communication between the PC and ADE7880 evaluation board and between LPC2368 and ADE7880. Bit 1 (I2C_LOCK) of the CONFIG2[7:0] register is now set to 1 to lock in the serial port choice. Then the DICOEFF register is initialized with 0xFFF8000, and the DSP of the ADE7880 is started when the software program writes RUN = 0x1. At the end of this process, the entire main menu is grayed out, and the submenu is enabled. You can now manage all functionality of the ADE7880 in PSM0 mode. To switch the ADE7880 to another power mode, click the Exit button on the submenu. The state of the Front Panel is shown in Figure 10. Configure Communication When Configure Communication is selected on the Front Panel, the panel shown in Figure 11 is opened. This panel is useful if an ADE7880 reset has been performed and the SPI is no longer the active serial port. Select the SPI port by clicking the I2C/SPI Selector button and then click OK to update the selection and lock the port. If the port selection is successful, the following message is displayed: Configuring LPC2368— ADE7880 communication was successful, and you must click OK to continue. If a communication error occurs, the following message is displayed: Configuring LPC2368—ADE7880 communication was not successful. Please check the communication between the PC and ADE7880 evaluation board. Rev. 0 | Page 13 of 56 UG-356 Evaluation Board User Guide included twice in the data path, but only the bit value from the current data path is written into the ADE7880. All the other instances take this value directly. 1. 10385-011 2. 3. Figure 11. Configure Communication Panel The CONFIG2[7:0] register is written with Bit 1 (I2C_LOCK) set to 1 so that you do not need to remember to set it once the communication is set. The contents of CONFIG2[7:0] are then read back and displayed with Bit 1 (I2C_LOCK). Click the Read Configuration button to read all ADE7880 registers that manage the total active power. Registers from the inactive data paths are also read and updated. Click the Write Configuration button to write all registers that manage the total active power into the ADE7880. Registers from the inactive data paths are also written. The ADE7880 status box shows the power mode that the ADE7880 is in (it should always be PSM0 in this window), the active serial port, and the CHECKSUM[31:0] register. After every read and write operation, the CHECKSUM[31:0] register is read and displayed. Click the CFx Configuration button to open a new panel (see Figure 13). This panel gives access to all bits and registers that configure the CF1, CF2, and CF3 outputs of the ADE7880. The Read Setup and Write Setup buttons update and display the CF1, CF2, and CF3 output values. To close the panel, click the Exit button; the cursor is positioned at Please select from the following options in the submenu of the Front Panel. Total Active Power 10385-013 When Total Active Power is selected on the Front Panel, the panel shown in Figure 12 is opened. The screen has an upper half and a lower half: the lower half shows the total active power data path of one phase, and the upper half shows bits, registers, and commands necessary for power management. Figure 13. CFx Configuration Panel 10385-012 Like the Total Active Power panel, the CHECKSUM[31:0] register is read back whenever a read or write operation is executed in the CFx Configuration panel. To select more than one option for a TERMSELx bit in the COMPMODE[15:0] register, press the CTRL key while clicking the options you want. Figure 12. Total Active Power Panel The Active Data Path menu manages which data path is shown in the bottom half. Some registers or bits, such as the WTHR[7:0] register or Bit 0 (INTEN) of the CONFIG[15:0] register, are common to all data paths, independent of the phase shown. When these registers are updated, all the values in all data paths are updated. Bit 0 (HPFEN) of the CONFIG3[7:0] register is Clicking the Exit button closes the panel and redisplays the Total Active Power panel. When the Read Energy Registers button in the Total Active Power panel is clicked, a new panel is opened (see Figure 14). This panel gives access to bits and registers that configure the energy accumulation. The Read Setup and Write Setup buttons update and display the bit and register values. The CHECKSUM[31:0] register is read back whenever a read or write operation is executed in the Read Energy Registers panel. Click the Read all energy registers button to read all energy registers immediately, without regard to the modes in which they function. Rev. 0 | Page 14 of 56 UG-356 10385-014 10385-015 Evaluation Board User Guide Figure 15. Fundamental Active Power Panel Figure 14. Read Energy Registers Panel 1. 2. 3. 4. 5. The STATUS0[31:0] register is read and then written back to so that all nonzero interrupt flag bits are cancelled. Bit 14 (CF1) in the MASK0[31:0] register is set to 1, and the interrupt protocol is started (see the Managing the Communication Protocol Between the Microcontroller and the ADE7880 section for protocol details). The microcontroller then waits until the IRQ0 pin goes low. If the wait is longer than the timeout you indicate in 3 sec increments, the following error message is displayed: No CF1 pulse was generated. Verify all the settings before attempting to read energy registers in this mode! When the IRQ0 pin goes low, the STATUS0[31:0] register is read and written back to cancel Bit 14 (CF1); then the energy registers involved in the CF1 signal are read and their contents are displayed. A timer in 10 ms increments can be used to measure the reaction time after the IRQ0 pin goes low. The operation is repeated until the Read energy registers synchronous with CF1 pulses button is clicked again. The process is similar when the other CF2, CF3, and line accumulation buttons are clicked in the Read Energy Registers panel. It is recommended that a timeout always be used when dealing with interrupts. By default, the timeout is set to 10 (indicating a 30 sec timeout), and the timer is set to 0 (indicating that the STATUSx[31:0] and energy registers are read immediately after the IRQ0 pin goes low). When clicked on the Front Panel, the Fundamental Active Power, and Fundamental Reactive Power buttons open panels that are very similar to the Total Active Power panel. These panels are shown in Figure 15 and Figure 16. 10385-016 The panel also gives the choice of reading the energy registers synchronous to CFx interrupts (pulses) or using line cycle accumulation mode. When the Read energy registers synchronous with CF1 pulses button is clicked, the following occurs: Figure 16. Fundamental Reactive Power Panel Harmonic Calculations When Harmonic Calculations is selected on the Front Panel, the panel shown in Figure 17 is opened. The panel is divided into two parts. The upper half provides status information, buttons to read and write registers related to the harmonic calculations, and the Exit button. The lower half contains harmonic calculations windows divided for each phase and neutral current. The phase used as the time base for the harmonic calculations is selected by the button on the upper left side of the panel. Bits[9:8] (ACTPHSEL) in the HCONFIG register are managed through this button. The harmonic indexes status window indicates what phase is under analysis and what harmonic indexes have been set into HX, HY and HZ registers. The ADE7880 status window indicates the power mode of the ADE7880, the active serial port, and the last read CHECKSUM register value. When the Read button is pressed, all the gain and offset registers that belong to the harmonic calculations are read together with all registers containing the harmonic calculations results. When the Write button is pressed, all the gain and offset registers that belong to the harmonic calculations are written into the ADE7880. Rev. 0 | Page 15 of 56 Evaluation Board User Guide 10385-017 10385-018 UG-356 Figure 17. Harmonic Analysis Panel Figure 18. Phase A Fundamental Info Panel Immediately after launch, the default panel is set to execute the harmonic analysis on Phase A. The user can select two quantities to analyze: current and voltage rms, active and reactive powers, apparent power and power factor, or current and voltage distortions. The program reads information starting with the fundamental and ending with Harmonic 63. Note that the pass-band frequency of the ADE7880 harmonic calculations is 2.8 kHz and any harmonic that is placed after that frequency is attenuated. Similarly, each phase and neutral have panels dedicated to the three harmonics that the ADE7880 can monitor at a time. The neutral line is analyzed together with the sum of the phase currents that the ADE7880 calculates into the ISUM register. In addition to the Phase Fundamental info panel, these panels contain options to select a harmonic index using one of the HX, HY or HZ registers. Type a number between 1 and 63 into the HX, HY or HZ window, set HPGAIN, the harmonic power gain register, the offset registers HX/HY/HZWATTOS, HX/HY/HZVAROS, HX/HY/HZIRMSOS and HX/HY/ HZVRMSOS, and then click the Write button. Then press Read button to read back the values of the registers together with the harmonic calculations results related to the panel: HX/HY/ HZWATT, HX/HY/HZVAR, HX/HY/HZIRMS, HX/HY/ HZVRMS, HX/HY/HZVA, HX/HY/HZPF, HX/HY/HZIHD, HX/HY/HZVHD. Figure 19 shows the Phase A Harmonic X panel. Note that the neutral current selection does not have a panel to manage the fundamental information. As for neutral current, the fundamental information is managed through the HX, HY or HZ registers. Set one of these registers to 1 to analyze the fundamental information related to neutral current and the sum of the phase currents. Next, the user can select how many samples are averaged before displaying the results. The default is 100 samples. The program automatically displays the average time it takes for the samples to be acquired based on HCONFIG register settings placed on the same panel: Bit 0 (HRCFG), Bits[4:3] (HSTIME), and Bits[7:5] (HRATE). When the Start Analysis button is pressed, the program instructs the ADE7880 to read all harmonic information, transfer it to the PC, and then displays it in dB relative to the acquired maximum harmonic value. Every phase has separate panels in which information on one single harmonic or on the fundamental can be managed. Figure 18 shows the Phase A Fundamental Info panel. APGAIN, the Phase A power gain register, together with offset compensation registers AFWATTOS, AFVAROS, AFIRMSOS, and AFVRMSOS can be set in this panel and then, by pressing the Write button in the upper half part, the values can be written into the ADE7880. When the Read button is pressed, all the control registers together with the harmonic calculations results related to the panel (FWATT, FVAR, FIRMS, FVRMS, FVA, FPF, ITHDN, and VTHDN) are read and then displayed. Rev. 0 | Page 16 of 56 Evaluation Board User Guide UG-356 Apparent Power 10385-019 When Apparent Power is selected on the Front Panel, a new panel is opened (see Figure 21). Similar to the other panels that deal with power measurement, this panel is divided into two parts: the lower half shows the apparent power data path of one phase and the ADE7880 status; the upper half shows the bits, registers, and commands necessary for power management. Figure 21. Apparent Power Panel RMS Current When RMS Current is selected on the Front Panel, a new panel is opened (see Figure 22). All data paths of all phases are available. 10385-022 Each phase and neutral has a panel called Real-Time Monitoring (see Figure 20). This panel allows the user to monitor up to four ADE7880 harmonic calculation outputs: one on the fundamental, one on harmonic HX, one on harmonic HY, and one on harmonic HZ. Select the quantity to monitor, introduce the harmonic that is monitored using the HX, HY, and HZ registers, select the number of samples to acquire in real time, select the HCONFIG register settings and click the Start Analysis button. If four quantities are monitored, only up to 2433 samples can be acquired. If three quantities are monitored, up to 3244 samples can be acquired. If two quantities are monitored, up to 4866 samples can be acquired. If only one quantity is monitored, up to 9732 samples can be acquired. The program then displays the samples on up to four diagrams, computes the mean, maximum and minimum values of the acquisitions, and displays them at the right side of every drawing. 10385-021 Figure 19. Phase A Harmonic X Panel Figure 22. Current RMS Panel 10385-020 Click the Read Setup button to read all registers shown in the panel. Click the Write Setup button to write to the xIRMSOS[23:0] registers. Figure 20. Phase A Real-Time Monitoring Panel You can use the Start Digital Signal Processor and Stop Digital Signal Processor buttons to manage the Run[15:0] register and the Read xIRMS registers button, which uses the ZXIA, ZXIB, and ZXIC interrupts at the IRQ1 pin, to read the xIRMS[23:0] registers 500 consecutive times and then compute and display their average. If no interrupt occurs for the time indicated by the timeout (in 3 sec increments), the following Rev. 0 | Page 17 of 56 UG-356 Evaluation Board User Guide message is displayed: No ZXIA, ZXIB or ZXIC interrupt was generated. Verify at least one sinusoidal signal is provided between IAP-IAN, IBP-IBN or ICP-ICN pins. A delay can be introduced (in 10 ms increments) between the time that the IRQ pin goes low and the moment the xIRMS registers are read. The operation is repeated until the button is clicked again. Mean Absolute Value Current 10385-024 When Mean Absolute Value Current is selected on the Front Panel, a new panel is opened (see Figure 23). When the Read xIMAV registers button is clicked, the xIMAV[19:0] registers are read 10 consecutive times, and their averages are computed and displayed. After this operation, the button is returned to high automatically. The ADE7880 status is also displayed. Figure 24. Voltage RMS Panel Power Quality 10385-023 The Power Quality panel is accessible from the Front Panel and is divided into two parts (see Figure 25). The lower part displays registers that manage the power quality measurement functions for the Active Measurement button in the upper part of the panel. The upper part also displays the ADE7880 status and the buttons that manage the measurements. Figure 23. Mean Absolute Value Current Panel RMS Voltage When RMS Voltage is selected on the Front Panel, the Voltage RMS panel is opened (see Figure 24). This panel is very similar to the Current RMS panel. Clicking the Read Setup button executes a read of the xVRMSOS[23:0] and xVRMS[23:0] registers. Clicking Write Setup writes the xVRMSOS[23:0] registers into the ADE7880. The Start Digital Signal Processor button manage the Run[15:0] register. When the Read xVRMS registers button is clicked, the xVRMS[23:0] registers are read 500 consecutive times and the average is displayed. The operation is repeated until the button is clicked again. Note that the ZXVA, ZXVB, and ZXVC zerocrossing interrupts are not used in this case because they are disabled when the voltages go below 10% of full scale. This allows rms voltage registers to be read even when the phase voltages are very low. When the READ CONFIGURATION button is clicked, all power quality registers (MASK1[31:0], STATUS1[31:0], ZXTOUT[15:0], APERIOD[15:0], BPERIOD[15:0], CPERIOD[15:0], MMODE[7:0], ISUM[27:0], OVLVL[23:0], OILVL[23:0], PHSTATUS[15:0], IPEAK[31:0], VPEAK[31:0], SAGLVL[23:0], SAGCYC[7:0], ANGLE0[15:0], ANGLE1[15:0], ANGLE2[15:0], COMPMODE[15:0], CHECKSUM[31:0], PEAKCYC[7:0], and ISUMLVL[23:0]) are read, and the registers that belong to the active panel are displayed. Based on the APERIOD[15:0], BPERIOD[15:0], and CPERIOD[15:0] registers, the line frequencies on every phase are computed and displayed in the lower part of the panel (Zero Crossing Measurements). Based on the ANGLEx[15:0] registers, cos(ANGLEx) is computed and displayed in the Time Intervals Between Phases panel that is accessible from the Active Measurement Zero Crossing menu box (see Figure 25). When the WRITE CONFIGURATION button is clicked, ZXTOUT[15:0], MMODE[7:0], OVLVL[23:0], OILVL[23:0], SAGLVL[23:0], SAGCYC[7:0], COMPMODE[15:0], PEAKCYC[7:0], and ISUMLVL[23:0] are written into the ADE7880, and CHECKSUM[31:0] is read back and displayed in the CHECKSUM[31:0] box at the top of the upper part of the panel. Rev. 0 | Page 18 of 56 UG-356 10385-025 10385-026 Evaluation Board User Guide Figure 26. Neutral Current Mismatch Panel Figure 25. Power Quality Zero-Crossing Measurements Panel The Active Measurement Zero Crossing button provides access to the Zero Crossing, Neutral Current Mismatch, Overvoltage and Overcurrent Measurements, Peak Detection, Sag Detection Panel, and Time Intervals Between Phases panels (see Figure 25 through Figure 30). 10385-027 When the WAIT FOR INTERRUPTS button is clicked, the interrupts that you enabled in the MASK1[31:0] register are monitored. When the IRQ1 pin goes low, the STATUS1[31:0] register is read and its bits are displayed. The ISUM[27:0], PHSTATUS[15:0], IPEAK[31:0], VPEAK[31:0], ANGLE0[15:0], ANGLE1[15:0], and ANGLE2[15:0] registers are also read and displayed. A timeout should be introduced in 3 sec increments to ensure that the program does not wait indefinitely for interrupts. A timer (in 10 ms increments) is provided to allow reading of the registers with a delay from the moment that the interrupt is triggered. Figure 27. Overvoltage and Overcurrent Measurements Panel The line frequency is computed using the xPERIOD[15:0] register, based on the following formula: f 256,000 [ Hz ] Period The cosine of the ANGLE0[15:0], ANGLE1[15:0], and ANGLE2[15:0] measurements is computed using the following formula: 10385-028 ANGLEx × 360 × f cos ( ANGLEx ) cos 256 ,000 Figure 28. Peak Detection Panel Rev. 0 | Page 19 of 56 Evaluation Board User Guide 10385-029 UG-356 10385-031 Figure 29. Sag Detection Panel Figure 31. Waveform Sampling Panel The HSDC transmits data to the NXP LPC2368 at 4 MHz because this is the maximum speed at which the slave SPI of the NXP LPC2368 can receive data. The panel contains some switches that must be set before acquiring data. 10385-030 Figure 30. Time Intervals Between Phases Panel Waveform Sampling The Waveform Sampling panel (see Figure 31) is accessible from the Front Panel and uses the HSDC port to acquire data from the ADE7880 and display it. It can be accessed only if the communication between the ADE7880 and the NXP LPC2368 is through the I2C interface. See the Activating Serial Communication Between the ADE7880 and the NXP LPC2368section for details on how to set I2C communication on the ADE7880 evaluation board. One switch chooses the quantities that are displayed: phase currents and voltages or phase powers. For every set of quantities, only one can be acquired at a time. This choice is made using the Select Waveform button. A second switch allows acquired data to be stored in files for further use. This switch is set with the Write waveforms to file?/No writing to files button. The acquisition time should also be set before an acquisition is initiated. By default, this time is 150 ms, but any value in milliseconds can be introduced. The NXP LPC2368 executes three tasks in real time using the ping pong buffer method: continuously receiving data from HSDC, storing the data into its USB memory, and sending the data to the PC. Transmitting seven phase currents and voltages at 4 MHz takes 103.25 μs (which is less than 125 μs); therefore, the HSDC update rate is 8 kHz (HSDC_CFG = 0x0F). Transmitting nine phase powers takes 72 μs (again, less than 125 μs); therefore, the HSDC update rate is also 8 kHz (HSDC_CFG = 0x11). To start the acquisition, click the ACQUIRE DATA button. The data is displayed on one plot. If you click the Write waveforms to file?/No writing to files switch to enable the writing of waveforms to a file, the program asks for the name and location of the files before storing the waveform. Rev. 0 | Page 20 of 56 Evaluation Board User Guide UG-356 Checksum Register 10385-033 The Checksum Register panel is accessible from the Front Panel and provides access to all ADE7880 registers that are used to compute the CHECKSUM[31:0] register (see Figure 32). You can read/write the values of these registers by clicking the Read and Write buttons. The LabVIEW program calculates the value of the CHECKSUM[31:0] register and displays it whenever one of the registers is changed. When the Read button is clicked, the registers are read, and the CHECKSUM[31:0] register is read and its values displayed. This allows you to compare the value of the CHECKSUM[31:0] register calculated by LabVIEW with the value read from the ADE7880. The values should always be identical. 10385-034 10385-032 Figure 33. Panel Giving Access to All ADE7880 Registers (1) Figure 32. Checksum Register Panel Figure 34. Panel Giving Access to All ADE7880 Registers (2) All Registers Access The All Registers Access panel is accessible from the Front Panel and provides read/write access to all ADE7880 registers. Because there are many registers, the panel scrolls up and down and has multiple read, write, and exit buttons (see Figure 33 and Figure 34). The registers are listed in columns in alphabetical order, starting at the upper left. The panel also allows you to save all control registers into a data file by clicking the Save All Regs into a file button. By clicking the Load All Regs from a file button, you can load all control registers from a data file. Then, by clicking the Write All Regs button, you can load these values into the ADE7880. Registers STATUS0 and STATUS1 are also written, so interrupt status flags can be cleared and IRQ0 and IRQ1 lines brought high. The order in which the registers are stored in a file is shown in the Control Registers Data File section. Quick Startup The Quick Startup panel is accessible from the Front Panel and can be used to rapidly initialize a 3-phase meter (see Figure 35). Rev. 0 | Page 21 of 56 UG-356 Evaluation Board User Guide Select the state of Bit 14 (SELFRQ) in the COMPMODE register based on the nominal line frequency, fn. Enable/disable the digital integrators in the phase and neutral current data paths by setting the Bit 0 (INTEN) of the CONFIG register and Bit 3 (ININTEN) of the CONFIG3 register, accordingly. At this point, the evaluation board is set up as a 3-phase meter, and calibration can be executed. To store the register initializations, click the Save All Regs into a file button in the All Registers Access panel (see Figure 33). After the board is powered down and then powered up again, the registers can be loaded into the ADE7880 by loading the contents of the data file. To do this, click the Load All Regs from a file button in the All Registers Access panel. 10385-035 PSM2 Settings Figure 35. Panel Used to Quickly Set Up the 3-Phase Meter The meter constant (MC, in impulses/kWh), the nominal voltage (VN, in V rms units), the nominal current (IN, in A rms units), and the nominal line frequency (fn, either 50 Hz or 60 Hz) must be set using the panel controls. Phase current, phase voltage, and neutral current PGA settings must also be provided. If Rogowski coils are used to sense the phase and neutral currents, integrators in the corresponding data paths must be enabled. Then phase voltages and phase currents must be provided through the relative sensors. The PSM2 Settings panel, which is accessible from the Front Panel, provides access to the LPOILVL[7:0] register that is used to access PSM2 low power mode (see Figure 36). You can edit the LPOIL[2:0] and LPLINE[4:0] bits. The value shown in the LPOILVL[7:0] register is composed from these bits and then displayed. Note that you cannot write a value into the register by writing a value in the LPOILVL[7:0] register box. The program then computes the full-scale voltages and currents and the constants that are important for setting up the ADE7880: the constant n, CFDEN, WTHR, VARTHR, VATHR, VLEVEL, and VNOM. After these values are calculated, you can overwrite these values. You can also click the Update Registers button to cause the program to do the following: Initialize the gain, CF1DEN, CF2DEN, CF3DEN, WTHR, VARTHR, VATHR, VLEVEL, and VNOM registers Enable the CF1 pin to provide a signal proportional to the total active power, the CF2 pin to provide a signal proportional to the fundamental reactive power, and the CF3 pin to provide a signal proportional to the apparent power. 10385-036 Clicking the Begin Computations button starts the program that reads rms voltages and currents and calculates the full-scale voltage and currents used to further initialize the meter. This process takes 7 sec as the program reads the rms voltages 100 times and the rms currents 100 times and then averages them (this is because the PC reads the rms values directly and cannot synchronize the readings with the zero crossings). Figure 36. PSM2 Settings Panel PSM1 MODE Enter PSM1 Mode When Enter PSM1 mode is selected on the Front Panel, the microcontroller manipulates the PM0 and PM1 pins of the ADE7880 to switch the ADE7880 into PSM1 reduced power mode. The submenu then allows access only to the Mean Absolute Value Current function because this is the only ADE7880 functionality available in this reduced power mode (see Figure 37). Rev. 0 | Page 22 of 56 10385-039 UG-356 10385-037 Evaluation Board User Guide Figure 37. Front Panel After the ADE7880 Enters PSM1 Mode Figure 39. Front Panel After the ADE7880 Enters PSM2 Mode Mean Absolute Value Current in PSM1 Mode Phase Current Monitoring The Mean Absolute Value Current panel, which is accessible from the Front Panel when Enter PSM1 mode is selected, is very similar to the panel accessible in PSM0 mode (see the Mean Absolute Value Current section for details). The only difference is that ADE7880 status does not show the CHECKSUM[31:0] register because it is not available in PSM1 mode (see Figure 38). The Phase Current Monitoring panel is accessible from the Front Panel when Enter PSM2 mode is selected; it allows you to display the state of the IRQ0 and IRQ1 pins because, in PSM2 low power mode, the ADE7880 compares the phase currents against a threshold determined by the LPOILVL[7:0] register (see Figure 40). Clicking the READ STATUS OF IRQ0 AND IRQ1 PINS button reads the status of these pins and displays and interprets the status. 10385-038 This operation is managed by the LPOILVL[7:0] register and can be modified only in PSM0 mode. The panel offers this option by switching the ADE7880 into PSM0 mode and then back to PSM2 mode when the READ LPOILVL/WRITE LPOILVL button is clicked. To avoid toggling both the PM0 and PM1 pins at the same time during this switch, the ADE7880 is set to PSM3 mode when changing modes. Figure 38. Mean Absolute Value Current Panel in PSM1 Mode PSM2 MODE When Enter PSM2 mode is selected on the Front Panel, the microcontroller manipulates the PM0 and PM1 pins of the ADE7880 to switch the ADE7880 into PSM2 low power mode. The submenu the allows access only to the Phase Current Monitoring function because this is the only ADE7880 functionality available in this low power mode. Rev. 0 | Page 23 of 56 10385-040 Enter PSM2 Mode Figure 40. Panel Managing Current Monitoring in PSM2 Mode UG-356 Evaluation Board User Guide PSM3 MODE Enter PSM3 Mode In PSM3 sleep mode, most of the internal circuits of the ADE7880 are turned off. Therefore, no submenu is activated in this mode. You can click the Enter PSM0 mode, Enter PSM1 mode, or Enter PSM2 mode button to set the ADE7880 to one of these power modes. Rev. 0 | Page 24 of 56 Evaluation Board User Guide UG-356 MANAGING THE COMMUNICATION PROTOCOL BETWEEN THE MICROCONTROLLER AND THE ADE7880 This section lists the protocol commands that have been implemented to manage the ADE7880 from the PC using the microcontroller. command, and sends an answer to the PC. The PC should wait for the answer before sending a new command to the microcontroller. The microcontroller is a pure slave during the communication process. It receives a command from the PC, executes the Table 3. Echo Command—Message from the PC to the Microcontroller Byte 0 1 2 3 4 … N N+1 Description A = 0x41 N = number of bytes transmitted after this byte Data Byte N − 1 (MSB) Data Byte N − 2 Data Byte N − 3 … Data Byte 1 Data Byte 0 (LSB) Table 4. Echo Command—Answer from the Microcontroller to the PC Byte 0 1 2 3 4 … N+1 N+2 Description R = 0x52 A = 0x41 N = number of bytes transmitted after this byte Data Byte N − 1 (MSB) Data Byte N − 2 … Data Byte 1 Data Byte 0 (LSB) Table 5. Power Mode Select—Message from the PC to the Microcontroller Byte 0 1 2 Description B = 0x42, change PSM mode N=1 Data Byte 0: 0x00 = PSM0 0x01 = PSM1 0x02 = PSM2 0x03 = PSM3 Table 6. Power Mode Select—Answer from the Microcontroller to the PC Byte 0 1 Description R = 0x52 ~ = 0x7E, to acknowledge that the operation was successful Table 7. Reset—Message from the PC to the Microcontroller Byte 0 1 2 Description C = 0x43, toggle the RESET pin and keep it low for at least 10 ms N=1 Data Byte 0: this byte can have any value Rev. 0 | Page 25 of 56 UG-356 Evaluation Board User Guide Table 8. Reset—Answer from the Microcontroller to the PC Byte 0 1 Description R = 0x52 ~ = 0x7E, to acknowledge that the operation was successful Table 9. I2C/SPI Select (Configure Communication)—Message from the PC to the Microcontroller Byte 0 1 2 Description D = 0x44, select I2C and SPI and initialize them; then set CONFIG2[7:0] = 0x2 to lock in the port choice. When I2C is selected, also enable SSP0 of the LPC2368 (used for HSDC). N = 1. Data Byte 0: 0x00 = I2C, 0x01 = SPI. Table 10. I2C/SPI Select (Configure Communication)—Answer from the Microcontroller to the PC Byte 0 1 Description R = 0x52 ~ = 0x7E, to acknowledge that the operation was successful Table 11. Data Write—Message from the PC to the Microcontroller Byte 0 1 2 3 4 5 6 … N+2 N+3 Description E = 0x45. N = number of bytes transmitted after this byte. N can be 1 + 2, 2 + 2, 4 + 2, or 6 + 2. MSB of the address. LSB of the address. Data Byte N − 3 (MSB). Data Byte N − 4. Data Byte N − 5. … Data Byte 1. Data Byte 0 (LSB). Table 12. Data Write—Answer from the Microcontroller to the PC Byte 0 1 Description R = 0x52 ~ = 0x7E, to acknowledge that the operation was successful Table 13. Data Read—Message from the PC to the Microcontroller Byte 0 1 2 3 4 Description F = 0x46. N = number of bytes transmitted after this byte; N = 3. MSB of the address. LSB of the address. M = number of bytes to be read from the address above. M can be 1, 2, 4, or 6. Table 14. Data Read—Answer from the Microcontroller to the PC Byte 0 1 2 3 4 5 6 7 8 Description R = 0x52. MSB of the address. LSB of the address. Byte 5, Byte 3, Byte 1, or Byte 0 (MSB) read at the location indicated by the address. The location may contain 6, 4, 2, or 1 byte. The content is transmitted MSB first. Byte 4, or Byte 2, or Byte 0. Byte 3, or Byte 1. Byte 2 or Byte 0. Byte 1. Byte 0. Rev. 0 | Page 26 of 56 Evaluation Board User Guide UG-356 Table 15. Interrupt Setup—Message from the PC to the Microcontroller Byte 0 1 2 3 4 5 6 7 8 9 Description J = 0x4A. N = 8, number of bytes transmitted after this byte. MSB of the MASK1[31:0] or MASK0[31:0] register. LSB of the MASK1[31:0] or MASK0[31:0] register. Byte 3 of the desired value of the MASK0[31:0] or MASK1[31:0] register. Byte 2. Byte 1. Byte 0. Timeout byte: time the MCU must wait for the interrupt to be triggered. It is measured in 3 sec increments. Timeout byte (TOB) = 0 means that timeout is disabled. IRQ timer: time the MCU leaves the IRQx pin low before writing back to clear the interrupt flag. It is measured in 10 ms increments. Timer = 0 means that timeout is disabled. Table 16. Interrupt Setup—Message from the Microcontroller to the PC Byte 0 1 2 3 4 Description R = 0x52. Byte 3 of the STATUS0[31:0] or STATUS1[31:0] register. If the program waited for TOB × 3 sec and the interrupt was not triggered, then Byte 3 = Byte 2 = Byte 1 = Byte 0 = 0xFF. Byte 2 of the STATUS0[31:0] or STATUS1[31:0] register. Byte 1 of the STATUS0[31:0] or STATUS1[31:0] register. Byte 0 of the STATUS0[31:0] or STATUS1[31:0] register. The microcontroller executes the following operations after the interrupt setup command is received: 1. 2. 3. 4. 5. Reads the STATUS0[31:0] or STATUS1[31:0] register (depending on the address received from the PC) and, if it shows an interrupt already triggered (one of its bits is equal to 1), it erases the interrupt by writing it back. Writes to the MASK0[31:0] or MASK1[31:0] register with the value received from the PC. Waits for the interrupt to be triggered. If the wait is more than the timeout specified in the command, 0xFFFFFFFF is sent back. If the interrupt is triggered, the STATUS0[31:0] or STATUS1[31:0] register is read and then written back to clear it. The value read at this point is the value sent back to the PC so that the user can see the source of the interrupts. Sends back the answer. Table 17. Interrupt Pins Status—Message from the PC to the Microcontroller Byte 0 1 2 Description H = 0x48. N = 1, number of bytes transmitted after this byte. Any byte. This value is not used by the program but it is used in the communication because N must not be equal to 0. Table 18. Interrupt Pins Status—Answer from the Microcontroller to the PC Byte 0 1 Description R = 0x52. A number representing the status of the IRQ0 and IRQ1 pins. 0: IRQ0 = low, IRQ1 = low. 1: IRQ0 = low, IRQ1 = high. 2: IRQ0 = high, IRQ1 = low. 3: IRQ0 = high, IRQ1 = high. The reason for the IRQ0 and IRQ1 order is that on the microcontroller I/O port, IRQ0 = P0.1 and IRQ1 = P0.0. Rev. 0 | Page 27 of 56 UG-356 Evaluation Board User Guide ACQUIRING HSDC DATA CONTINUOUSLY This function acquires data from the HSDC continuously for a defined time period and for up to two variables. The microcontroller sends data in packages of 4 kB. Table 19 describes the protocol when two instantaneous phase currents or voltages are acquired. Table 19. Acquire HSDC Data Continuously—Message from the PC to the Microcontroller If Phase Currents and Voltages Are Acquired Byte 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Description G = 0x47. N = number of bytes transmitted after this byte. N = 32. 0: corresponds to Byte 3 of IA. Because this byte is only a sign extension of Byte 2, it is not sent back by the microcontroller. Increment_IA_Byte2. If IA is to be acquired, Byte 3, Byte 4, and Byte 5 are 1. Otherwise, they are 0. Increment_IA_Byte1. Increment_IA_Byte2. 0. Increment_VA_Byte2. If VA is to be acquired, Byte 7, Byte 8, and Byte 9 are 1. Otherwise, they are 0. Increment_VA_Byte1. Increment_VA_Byte0. 0. Increment_IB_Byte2. If IB is to be acquired, Byte 11, Byte 12, and Byte 13 are 1. Otherwise, they are 0. Increment_IB_Byte1. Increment_IB_Byte0. 0. Increment_VB_Byte2. If VB is to be acquired, Byte 15, Byte 16, and Byte 17 are 1. Otherwise, they are 0. Increment_VB_Byte1. Increment_VB_Byte0. 0. Increment_IC_Byte2. If IC is to be acquired, Byte 19, Byte 20, and Byte 21 are 1. Otherwise, they are 0. Increment_IC_Byte1. Increment_IC_Byte0. 0. Increment_VC_Byte2. If VC is to be acquired, Byte 23, Byte 24, and Byte 25 are 1. Otherwise, they are 0. Increment_VC_Byte1. Increment_VC_Byte0. 0. Increment_IN_Byte2. If IN is to be acquired, Byte 27, Byte 28, and Byte 29 are 1. Otherwise, they are 0. Increment_IN_Byte1. Increment_IN_Byte0. Byte 1 of M. M is a 16-bit number. The number of 32-bit samples acquired by the microcontroller is (2 × M + 1) × 67 per channel. Byte 0 of M. Rev. 0 | Page 28 of 56 Evaluation Board User Guide UG-356 If two of the phase powers are to be acquired, the protocol changes (see Table 20). Table 20. Acquire HSDC Data Continuously—Message from the PC to the Microcontroller If Phase Powers Are Acquired Byte 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Description G = 0x47. N = number of bytes transmitted after this byte. N = 38. 0: corresponds to Byte 3 of AVA. Because this byte is only a sign extension of Byte 2, it is not sent back by the microcontroller. Increment_AVA_Byte2. If AVA is to be acquired, Byte 3, Byte 4, and Byte 5 are 1. Otherwise, they are 0. Increment_AVA_Byte1. Increment_AVA_Byte2. 0. Increment_BVA_Byte2. If BVA is to be acquired, Byte 7, Byte 8, and Byte 9 are 1. Otherwise, they are 0. Increment_BVA_Byte1. Increment_BVA_Byte0. 0. Increment_CVA_Byte2. If CVA is to be acquired, Byte 11, Byte 12, and Byte 13 are 1. Otherwise, they are 0. Increment_CVA_Byte1. Increment_CVA_Byte0. 0. Increment_AWATT_Byte2. If AWATT is to be acquired, Byte 15, Byte 16, and Byte 17 are 1. Otherwise, they are 0. Increment_AWATT_Byte1. Increment_AWATT_Byte0. 0. Increment_BWATT_Byte2. If BWATT is to be acquired, Byte 19, Byte 20, and Byte 21 are 1. Otherwise, they are 0. Increment_BWATT_Byte1. Increment_BWATT_Byte0. 0. Increment_CWATT_Byte2. If CWATT is to be acquired, Byte 23, Byte 24, and Byte 25 are 1. Otherwise, they are 0. Increment_CWATT_Byte1. Increment_CWATT_Byte0. 0. Increment_AVAR_Byte2. If AVAR is to be acquired, Byte 27, Byte 28, and Byte 29 are 1. Otherwise, they are 0. Increment_AVAR_Byte1. Increment_AVAR_Byte0. 0. Increment_BVAR_Byte2. If BVAR is to be acquired, Byte 31, Byte 32, and Byte 33 are 1. Otherwise, they are 0. Increment_BVAR_Byte1. Increment_BVAR_Byte0. 0. Increment_CVAR_Byte2. If CVAR is to be acquired, Byte 35, Byte 36, and Byte 37 are 1. Otherwise, they are 0. Increment_CVAR_Byte1. Increment_CVAR_Byte0. Byte 1 of M. M is a 16-bit number. The number of 32-bit samples acquired by the microcontroller is (2 × M + 1) × 67 per channel. Byte 0 of M. Rev. 0 | Page 29 of 56 UG-356 Evaluation Board User Guide After receiving the command, the microcontroller enables the HSDC port and acquires 67 × 7 × 4 = 1876 bytes into BUFFER0. As soon as BUFFER0 is filled, data is acquired in BUFFER1 (equal in size to BUFFER0), while 2 × 3 × 67 = 402 bytes (134 24-bit words) from BUFFER0 are transmitted to the PC. As soon as BUFFER1 is filled, data is acquired into BUFFER0 while 402 bytes from BUFFER1 are transmitted to the PC. Only the least significant 24 bits of every 32-bit instantaneous value are sent to the PC to decrease the size of the buffer sent to the PC. The most significant eight bits are only an extension of a 24-bit signed word; therefore, no information is lost. The protocol used by the microcontroller to send data to the PC is shown in Table 21. Table 21. Acquire HSDC Data Continuously—Answer from the Microcontroller to the PC Byte 0 1 2 3 4 5 … 402 Description R = 0x52 Byte 2 (MSB) of Word 1 Byte 1 of Word 1 Byte 0 (LSB) of Word 1 Byte 2 (MSB) of Word 2 Byte 1 (MSB) of Word 2 … Byte 0 (LSB) of Word 134 STARTING THE ADE7880 DSP This function orders the microcontroller to start the DSP. The microcontroller writes to the run register with 0x1. Table 22. Start ADE7880 DSP—Message from the PC to the Microcontroller Byte 0 1 2 Description N = 0x4E N = number of bytes transmitted after this byte; N = 1 Any byte Table 23. Start ADE7880 DSP—Answer from the Microcontroller to the PC Byte 0 1 Description R = 0x52 ~ = 0x7E, to acknowledge that the operation was successful STOPPING THE ADE7880 DSP This function orders the microcontroller to stop the DSP. The microcontroller writes to the run register with 0x0. Table 24. Stop ADE7880 DSP—Message from the PC to the Microcontroller Byte 0 1 2 Description O = 0x4F N = number of bytes transmitted after this byte; N = 1 Any byte Table 25. Stop ADE7880 DSP—Answer from the Microcontroller to the PC Byte 0 1 Description R = 0x52 ~ = 0x7E to acknowledge that the operation was successful Table 26. Harmonic Calculations Management—Message from the PC to the Microcontroller Byte 0 1 2 3 4 5 Description S = 0x53 N = number of bytes transmitted after this byte; N = 7 MS Byte 3 of the number of samples N_samples Byte 2 of the number of samples N_samples Byte 1 of the number of samples N_samples LS Byte 0 of the number of samples N_samples Rev. 0 | Page 30 of 56 Evaluation Board User Guide Byte 6 7 8 UG-356 Description Phase A, Phase B, or Phase C variables under analysis: 0 = VRMS and IRMS 1 = WATT and VAR 2 = VA and PF 3 = VHD and IHD Neutral current and ISUM variables under analysis: 0 = ISUMRMS and NIRMS 3 = ISUMHD and NIHD MS byte of HCONFIG LS byte of HCONFIG Table 27. Harmonic Calculations Management—Answer from the Microcontroller to the PC Byte 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 … 24 …. 32 … 40 … 62 × 16 = 992 …. 8 + 62 × 16 = 1000 … 1007 Description LS Byte 0 of 64-bit fundamental of the first quantity (Q1) to monitor: VRMS or WATT or VA or VHD Byte 1 of 64-bit fundamental Q1 Byte 2 of 64-bit fundamental Q1 Byte 3 of 64-bit fundamental Q1 Byte 4 of 64-bit fundamental Q1 Byte 5 of 64-bit fundamental Q1 Byte 6 of 64-bit fundamental Q1 MS Byte 7 of 64-bit fundamental Q1 LS Byte 0 of 64-bit fundamental of the second quantity (Q2) to monitor: IRMS or VAR or PF or IHD Byte 1 of 64-bit fundamental Q2 Byte 2 of 64-bit fundamental Q2 Byte 3 of 64-bit fundamental Q2 Byte 4 of 64-bit fundamental Q2 Byte 5 of 64-bit fundamental Q2 Byte 6 of 64-bit fundamental Q2 Byte 7 of 64-bit fundamental Q2 LS Byte 0 of 64-bit Harmonic 2 Q1 LS Byte 0 of 64-bit Harmonic 2 Q2 LS Byte 0 of 64-bit Harmonic 3 Q1 LS Byte 0 of 64-bit Harmonic 3 Q2 LS Byte 0 of 64-bit Harmonic 63 Q1 LS Byte 0 of 64-bit Harmonic 63 Q2 MS Byte 7 of 64-bit Harmonic 63 Q2 Rev. 0 | Page 31 of 56 UG-356 Evaluation Board User Guide Table 28. Real-Time Monitoring of Harmonics—Message from the PC to the Microcontroller Byte 0 1 2 3 4 5 6 7 8 9 10 Description T = 0x54. N = number of bytes transmitted after this byte; N = 9. Byte identifying the fundamental and HX components to monitor. If neutral current is monitored, the F components are set to 0. Bits[3:0] identify the fundamental component to monitor: 0 = no fundamental component to monitor. 1 = FVRMS. 2 = FIRMS. 3 = FWATT. 4 = FVAR. 5 = FVA. 6 = FPF. 7 = VTHDN. 8 = ITHDN. Bits[7:4] identify the HX component to monitor. 0 = no HX component to monitor. 1 = HXVRMS. 2 = HXIRMS. 3 = HXWATT. In neutral current case, this option is reserved. 4 = HXVAR. In neutral current case, this option is reserved. 5 = HXVA. In neutral current case, this option is reserved. 6 = HXPF. In neutral current case, this option is reserved. 7 = HXVHD. 8 = HXIHD. Byte identifying the HY and HZ components to monitor. Bits[3:0] identify the HY component to monitor: 0 = no HY component to monitor. 1 = HYVRMS. 2 = HYIRMS. 3 = HYWATT. In neutral current case, this option is reserved. 4 = HYVAR. In neutral current case, this option is reserved. 5 = HYVA. In neutral current case, this option is reserved. 6 = HYPF. In neutral current case, this option is reserved. 7 = HYVHD. 8 = HYIHD. Bits[7:4] identify the HZ component to monitor. 0 = no HZ component to monitor. 1 = HZVRMS. 2 = HZIRMS. 3 = HZWATT. In neutral current case, this option is reserved. 4 = HZVAR. In neutral current case, this option is reserved. 5 = HZVA. In neutral current case, this option is reserved. 6 = HZPF. In neutral current case, this option is reserved. 7 = HZVHD. 8 = HZIHD. Byte equal to the LS byte (Byte 0) of HX register. Byte equal to the LS byte (Byte 0) of HY register. Byte equal to the LS byte (Byte 0) of HZ register. MS byte of the number of samples N_samples. LS byte of the number of samples N_samples. MS byte of HCONFIG. LS byte of HCONFIG. Rev. 0 | Page 32 of 56 Evaluation Board User Guide UG-356 Table 29. Real-Time Monitoring of Harmonics1 Byte 0 1 2 3 4 5 … 3 × N_sample-3 3 × N_sample-2 3 × N_sample-1 1 Description Byte 2 of Sample 0 Byte 1 of Sample 0 Byte 0 of Sample 0 Byte 2 of Sample 1 Byte 1 of Sample 1 Byte 0 of Sample 1 Byte 2 of Sample N_sample-1 Byte 1 of Sample N_sample-1 Byte 0 of Sample N_sample-1 Answer from the microcontroller to the PC if one quantity is monitored. Table 30. Real-Time Monitoring of Harmonics1 Byte 0 1 2 3 4 5 6 7 8 9 10 11 … 3 × 2 × N_sample-3 3 × 2 × N_sample-2 3 × 2 × N_sample-1 1 Description Byte 2 of Sample 0 of Q1 Byte 1 of Sample 0 of Q1 Byte 0 of Sample 0 of Q1 Byte 2 of Sample 0 of Q2 Byte 1 of Sample 0 of Q2 Byte 0 of Sample 0 of Q2 Byte 2 of Sample 1 of Q1 Byte 1 of Sample 1 of Q1 Byte 0 of Sample 1 of Q1 Byte 2 of Sample 1 of Q2 Byte 1 of Sample 1 of Q2 Byte 0 of Sample 1 of Q2 Byte 2 of Sample N_sample-1 of Q2 Byte 1 of Sample N_sample-1 of Q2 Byte 0 of Sample N_sample-1 of Q2 Answer from the microcontroller to the PC if two quantities, Q1 and Q2, are monitored. Table 31. Real-Time Monitoring of Harmonics1 Byte 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 … Description Byte 2 of Sample 0 of Q1 Byte 1 of Sample 0 of Q1 Byte 0 of Sample 0 of Q1 Byte 2 of Sample 0 of Q2 Byte 1 of Sample 0 of Q2 Byte 0 of Sample 0 of Q2 Byte 2 of Sample 0 of Q3 Byte 1 of Sample 0 of Q3 Byte 0 of Sample 0 of Q3 Byte 2 of Sample 1 of Q1 Byte 1 of Sample 1 of Q1 Byte 0 of Sample 1 of Q1 Byte 2 of Sample 1 of Q2 Byte 1 of Sample 1 of Q2 Byte 0 of Sample 1 of Q2 Byte 2 of Sample 1 of Q3 Byte 1 of Sample 1 of Q3 Byte 0 of Sample 1 of Q3 Rev. 0 | Page 33 of 56 UG-356 Byte 3 × 3 × N_sample-3 3 × 3 × N_sample-2 3 × 3 × N_sample-1 1 Evaluation Board User Guide Description Byte 2 of Sample N_sample-1 of Q3 Byte 1 of Sample N_sample-1 of Q3 Byte 0 of Sample N_sample-1 of Q3 Answer from the microcontroller to the PC if three quantities, Q1, Q2, and Q3, are monitored Table 32. Real-Time Monitoring of Harmonics1 Byte 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 … 3 × 4 × N_sample-3 3 × 4 × N_sample-2 3 × 4 × N_sample-1 1 Description Byte 2 of Sample 0 of Q1 Byte 1 of Sample 0 of Q1 Byte 0 of Sample 0 of Q1 Byte 2 of Sample 0 of Q2 Byte 1 of Sample 0 of Q2 Byte 0 of Sample 0 of Q2 Byte 2 of Sample 0 of Q3 Byte 1 of Sample 0 of Q3 Byte 0 of Sample 0 of Q3 Byte 2 of Sample 0 of Q4 Byte 1 of Sample 0 of Q4 Byte 0 of Sample 0 of Q4 Byte 2 of Sample 1 of Q1 Byte 1 of Sample 1 of Q1 Byte 0 of Sample 1 of Q1 Byte 2 of Sample 1 of Q2 Byte 1 of Sample 1 of Q2 Byte 0 of Sample 1 of Q2 Byte 2 of Sample 1 of Q3 Byte 1 of Sample 1 of Q3 Byte 0 of Sample 1 of Q3 Byte 2 of Sample 1 of Q4 Byte 1 of Sample 1 of Q4 Byte 0 of Sample 1 of Q4 Byte 2 of Sample N_sample-1 of Q4 Byte 1 of Sample N_sample-1 of Q4 Byte 0 of Sample N_sample-1 of Q4 Answer from the microcontroller to the PC if four quantities, Q1, Q2, Q3, and Q4, are monitored. Rev. 0 | Page 34 of 56 Evaluation Board User Guide UG-356 UPGRADING MICROCONTROLLER FIRMWARE Although the evaluation board is supplied with the microcontroller firmware already installed, the ADE7880 evaluation software CD provides the NXP LPC2368 microcontroller project developed under the IAR embedded workbench environment for ARM. Users in possession of this tool can modify the project at will and can download it using an IAR J-link debugger. As an alternative, the executable can be downloaded using a program called Flash Magic, available on the evaluation software CD or at the Flash Magic website. 1. 2. 3. 4. 5. 6. 7. Plug a serial cable into connector P15 of the ADE7880 evaluation board and into a PC COM port. As an alternative, use the ADE8052Z-DWDL1 ADE downloader from Analog Devices, Inc., together with a USB cable. Launch the Device Manager under Windows XP by writing devmgmt.msc into the Start/Run box. This helps to identify which COM port is used by the serial cable. Plug the USB2UART board into the P15 connector of the ADE7880 evaluation board with the VDD pin of the USB2UART aligned at Pin 1 of P15. Supply the microcontroller side of the board by connecting a USB cable between a PC and the P1 connector of the board. Press the S3 button. The P2.10/EINT0 pin of the microcontroller is now connected to ground. While keeping the S3 button pressed, press and release the reset button, S2, on the ADE7880 evaluation board. Then release S3. Launch Flash Magic and do the following: a. Select a COM port (COMx as seen in the Device Manager). b. Set the baud rate to 115,200. c. Select the NXP LPC2368 device. d. Set the interface to none (ISP). e. Set the oscillator frequency (MHz) to 12.0. f. Select Erase all Flash + Code Rd Block. g. Choose ADE7880_Eval_Board.hex from the \Debug\Exe project folder. h. Select Verify after programming. 10385-041 Flash Magic uses the PC COM port to download the microcontroller firmware. The procedure for using Flash Magic is as follows: Figure 41. Flash Magic Settings 8. 9. Click Start to begin the download process. After the process finishes, remove the USB cable from the P1 connector and reinsert it. Supply 3.3 V at P9 connector to supply the ADE7880 side of the board. The board is now ready to operate. 10. When the PC recognizes the evaluation board and asks for a driver, select the project \VirCOM_Driver_XP folder if Windows XP is the operating system. The ADE7880_eval_board_vircomport.inf file is the driver. If the operating system is Windows 7 64-bit, the driver is in the VirCOM_Driver_W7_64bit folder. The ADE7880_ eval_board_vircomport_W7_64bit.inf file is the driver. The Flash Magic settings are shown in Figure 41. Rev. 0 | Page 35 of 56 UG-356 Evaluation Board User Guide CONTROL REGISTERS DATA FILE Table 33 shows the order in which the control registers of the ADE7880 are stored into a data file when you click the Save All Regs into a file button in the All Registers Access panel. Table 33. Control Register Data File Contents Line Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Register ACCMODE AFIRMSOS AFVAROS AFVRMSOS AFWATTOS AIGAIN AIRMSOS APHCAL APGAIN APNOLOAD AVGAIN AVRMSOS AWATTOS BFIRMSOS BFVAROS BFVRMSOS BFWATTOS BIGAIN BIRMSOS BPHCAL BPGAIN BVGAIN BVRMSOS BWATTOS CF1DEN CF2DEN CF3DEN CFCYC CFIRMSOS CFMODE CFVAROS CFVRMSOS CFWATTOS CIGAIN CIRMSOS COMPMODE CONFIG CONFIG2 CONFIG3 CPHCAL CPGAIN CVGAIN CVRMSOS CWATTOS DICOEFF GAIN HCONFIG HPGAIN HSDC_CFG Rev. 0 | Page 36 of 56 Evaluation Board User Guide Line Number 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 UG-356 Register HX HXIRMSOS HXVAROS HXVRMSOS HXWATTOS HY HYIRMSOS HYVAROS HYVRMSOS HYWATTOS HZ HZIRMSOS HZVAROS HZVRMSOS HZWATTOS ISUMLVL LCYCMODE LINECYC LPOILVL MASK0 MASK1 MMODE NIGAIN NIRMSOS OILVL OVLVL PEAKCYC RUN SAGCYC SAGLVL VANOLOAD VARNOLOAD VARTHR VATHR VLEVEL VNOM ZXTOUT WTHR Rev. 0 | Page 37 of 56 UG-356 Evaluation Board User Guide EVALUATION BOARD SCHEMATICS AND LAYOUT 10385-042 SCHEMATIC 10385-043 Figure 42. ADE7880 Schematic Figure 43. Isolated Connections of CF Pins Rev. 0 | Page 38 of 56 UG-356 10385-044 Evaluation Board User Guide 10385-045 Figure 44. Communication Protocol Selection Figure 45. Ground Connections Rev. 0 | Page 39 of 56 Evaluation Board User Guide 10385-046 UG-356 Figure 46. Device Interface Header Rev. 0 | Page 40 of 56 UG-356 10385-047 Evaluation Board User Guide 10385-048 Figure 47. ADE7880 Clock Circuitry Figure 48. I/O Selection Rev. 0 | Page 41 of 56 Evaluation Board User Guide 10385-049 UG-356 Figure 49. Isolation Circuitry Rev. 0 | Page 42 of 56 UG-356 10385-050 Evaluation Board User Guide 10385-051 Figure 50. JTAG Interface Port Figure 51. LPC2368 Schematic Rev. 0 | Page 43 of 56 Evaluation Board User Guide 10385-052 UG-356 10385-053 Figure 52. Ground Test Points 10385-054 Figure 53. MCU Override Figure 54. MCU Pin Connections Rev. 0 | Page 44 of 56 UG-356 10385-055 Evaluation Board User Guide 10385-056 Figure 55. Interface Header When MCU is Bypassed 10385-057 Figure 56. Power Supply Decoupling Figure 57. MCU Power Supply Selection Rev. 0 | Page 45 of 56 Evaluation Board User Guide 10385-058 UG-356 10385-059 Figure 58. MCU Power Supply Regulator 10385-060 Figure 59. MCU Reset and Boot Switches 10385-061 Figure 60. MCU Clock Circuit Figure 61. Neutral Current Circuit Rev. 0 | Page 46 of 56 UG-356 10385-062 Evaluation Board User Guide 10385-063 Figure 62. VN Circuit Figure 63. Output LED Circuit Rev. 0 | Page 47 of 56 Evaluation Board User Guide 10385-064 UG-356 10385-065 Figure 64. Phase A Current 10385-066 Figure 65. Phase A Voltage Figure 66. Phase B Current Rev. 0 | Page 48 of 56 UG-356 10385-067 Evaluation Board User Guide 10385-068 Figure 67. Phase B Voltage 10385-069 Figure 68. Phase C Current Figure 69. Phase C Voltage Rev. 0 | Page 49 of 56 Evaluation Board User Guide 10385-070 UG-356 10385-071 Figure 70. Power Supply Connections 10385-072 Figure 71. Reference Voltage Circuit Figure 72. ADE7880 Reset Circuit Rev. 0 | Page 50 of 56 UG-356 10385-073 Evaluation Board User Guide 10385-074 Figure 73. UART Circuit Figure 74. USB Interface 10385-075 LAYOUT Figure 75. Layer Top Layer Rev. 0 | Page 51 of 56 Evaluation Board User Guide 10385-076 UG-356 10385-077 Figure 76. Layer 2 Figure 77. Layer 3 Rev. 0 | Page 52 of 56 UG-356 10385-078 Evaluation Board User Guide Figure 78. Bottom Layer Rev. 0 | Page 53 of 56 UG-356 Evaluation Board User Guide ORDERING INFORMATION BILL OF MATERIALS Table 34. Qty 1 1 10 30 5 20 27 4 3 3 2 1 3 5 2 1 12 1 13 10 29 2 2 2 3 11 Designator A1 A2 AGND1 to AGND10 VN, CF1, IAN, IAP, IBN, IBP, ICN, ICP, INN, INP, PM0, PM1, REF, VAP, VBP, VCP, AVDD, DVDD, XREF, CLKIN, IRQ0, IRQ1, CLKOUT, RESET, SS/HSA, MISO/HSD, MOSI/SDA, SCLK/SCL, CF3/HSCLK, CF2/HREADY C1, C8, C61, C62, C64 C9 to C28 C2, C7, C33 to C35, C37, C38, C40 to C46, C48 to C60 C29, C30, C65, C66 C3, C5, C36 C32, C67, C68 C4, C6 C63 CF1_ISO to CF3_ISO CR1 to CR5 CR6, CR7 D1 E1A to E3A, E1B to E3B, E1C to E3C, E1N to E3N EXT_CLKIN HSA_ISO, SCL_ISO, SDA_ISO, SSB_ISO, MISO_ISO, MOSI_ISO, PM0_CTRL, PM1_CTRL, SCLK_ISO, IRQ0B_ISO, IRQ1B_ISO, RESB_CTRL, HSDATA_ISO JP11, JP24, JP31 to JP34, JP7A, JP7B, JP7C, JP7N JP12, JP1A to JP6A, JP1B to JP6B, JP1C to JP6C, JP1N to JP6N, JP21, JP9A, JP9B, JP9C JP22, JP23 JP61, JP62 VDD, MCU_VDD MGND1 to MGND3 P1 to P10, P12 Description IC, 1.2 V ultralow power high PSRR voltage reference IC, swappable dual isolator Connector, PCB, test point, black Connector, PCB, test point, grey Capacitor, monolithic, ceramic, 10 μF Capacitor, ceramic chip, C0G, 0603, 2.2 nF Capacitor, X7R, 0805, 100 nF Manufacturer/Part Number Analog Devices/ADR280ARTZ Analog Devices/ADuM1250ARZ COMPONENTS_CORPORATION/TP-104-01-00 COMPONENTS_CORPORATION/TP-104-01-08 Murata/GRM21BR61C106KE15L TDK/C1608C0G1H222J Murata/GRM21BR71H104KA01L Capacitor, monolithic, ceramic, C0G, 0402, 20 pF Capacitor, ceramic, 0805, X5R, 4.7 μF Capacitor, ceramic, 1206, X7R, 1 μF Capacitor, ceramic, X7R, 0.22 μF Capacitor, ceramic, X7R, 0.01 μF Connector, PCB coax, vertical, BNC, 50 Ω Diode, LED, green, SMD LED, green, surface mount Diode, 6.2 V, Zener, SMA Inductor, chip, ferrite bead, 0805, 1500 Ω Connector, PCB coax, SMB, RA Connector, PCB, test point, white Murata/GRM1555C1H200JZ01D Taiyo Yuden/EMK212BJ475KG-T Taiyo Yuden/GMK316B7105KL-T Phycomp (Yageo)/2222 780 15654 AVX/0306ZC103KAT2A Tyco Electronics/5227699-2 Chicago Mini Lamp/CMD28-21VGCTR8T1 Lumex/SML-LXT0805GW-TR Micro Commercial Co./SMAJ4735A-TP Murata/BLM21BD152SN1D Johnson/131-3701-301 COMPONENTS_CORPORATION/TP-104-01-09 3-pin jumper N/A/ Connector, PCB Berg jumper, ST, male 2-pin Resistor jumper, SMD 1206 (short) Resistor jumper, SMD 0805 (open) Connector, PCB, test point, red Connector, PCB, test point, green Connector, PCB term, black, 2-pin, ST Rev. 0 | Page 54 of 56 BERG/69157-102 Panasonic/ERJ-8GEYJ0.0 Panasonic/ERJ-6GEYJ0.0 COMPONENTS_CORPORATION/TP-104-01-02 COMPONENTS_CORPORATION/TP-104-01-05 Weiland/25.161.0253 Evaluation Board User Guide Qty 2 Designator P11, P17 1 1 P13 P14 1 1 5 8 P15 P16 Q1 to Q5 R9 to R16 15 R17 to R25, R29 to R34 3 R26 to R28 37 5 R37, R43 to R56, R59 to R65, R67 to R75, R77, R81 to R85 R38 to R42 1 1 1 R57 R58 R66 2 2 3 4 1 1 R76, R80 R78, R79 S1 to S3 U3, U4, U6, U7 U8 U9 1 1 Y1 Y2 UG-356 Description Connector, PCB, header, SHRD, ST, male 32-pin Connector, PCB, header, ST, male 20-pin Connector, PCB, USB, Type B, R/A, through hole Connector, PCB, header, ST, male 4-pin Connector, PCB, straight header 3-pin Trans digital FET P channel Resistor, precision thick film, chip R1206, 100 Ω Resistor, precision thick film, chip R0805, 1 kΩ Resistor, precision thick film, chip R0805, 1 MΩ Resistor, precision thick film, chip R0805, 10 kΩ Manufacturer/Part Number Samtec/TSW-1-30-08-G-D Samtec/TSW-110-08-G-D AMP/4-1734376-8 Samtec/TSW-104-08-G-S Molex/22-03-2031 Fairchild/FDV302P Panasonic/ERJ-8ENF1000V Panasonic/ERJ-6ENF1001V Panasonic/ERJ-6ENF1004V Panasonic/ERJ-6ENF1002V Resistor, precision thick film, chip R1206, 499 Ω Resistor, film, SMD 0805, 220 kΩ Resistor, film, SMD 0805, 330 kΩ Resistor, PREC, thick film chip, R1206, 1.5 kΩ Resistor, film, SMD 0805, 680 Ω Resistor, film, SMD 1206, 27 Ω SW SM mechanical key switch IC quad channel digital isolator IC ARM7, MCU, flash, 512K 100 LQFP IC 300mA low dropout CMOS linear regulator IC crystal, 16.384 MHz IC crystal quartz, 12.0 MHz Rev. 0 | Page 55 of 56 Panasonic/ERJ-8ENF4990V Multicomp/MC 0.1W 0805 1% 220K Panasonic/ERJ-6GEYJ334V Panasonic/ERJ-8ENF1501V Multicomp/MC 0.1W 0805 1% 680R Phycomp (Yageo)/9C12063A27R0FKHFT Omron/B3S1000 Analog Devices/ADuM3401CRWZ NXP/LPC2368FBD100 Analog Devices/ADP1713AUJZ-3.3-R7 Valpey Fisher Corporation/VM6-1D11C12-TR-16.384 MHz ECS/ECS-120-20-4X UG-356 Evaluation Board User Guide NOTES I2C refers to a communications protocol originally developed by Philips Semiconductors (now NXP Semiconductors). ESD Caution ESD (electrostatic discharge) sensitive device. Charged devices and circuit boards can discharge without detection. Although this product features patented or proprietary protection circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality. Legal Terms and Conditions By using the evaluation board discussed herein (together with any tools, components documentation or support materials, the “Evaluation Board”), you are agreeing to be bound by the terms and conditions set forth below (“Agreement”) unless you have purchased the Evaluation Board, in which case the Analog Devices Standard Terms and Conditions of Sale shall govern. Do not use the Evaluation Board until you have read and agreed to the Agreement. Your use of the Evaluation Board shall signify your acceptance of the Agreement. This Agreement is made by and between you (“Customer”) and Analog Devices, Inc. (“ADI”), with its principal place of business at One Technology Way, Norwood, MA 02062, USA. Subject to the terms and conditions of the Agreement, ADI hereby grants to Customer a free, limited, personal, temporary, non-exclusive, non-sublicensable, non-transferable license to use the Evaluation Board FOR EVALUATION PURPOSES ONLY. Customer understands and agrees that the Evaluation Board is provided for the sole and exclusive purpose referenced above, and agrees not to use the Evaluation Board for any other purpose. Furthermore, the license granted is expressly made subject to the following additional limitations: Customer shall not (i) rent, lease, display, sell, transfer, assign, sublicense, or distribute the Evaluation Board; and (ii) permit any Third Party to access the Evaluation Board. As used herein, the term “Third Party” includes any entity other than ADI, Customer, their employees, affiliates and in-house consultants. The Evaluation Board is NOT sold to Customer; all rights not expressly granted herein, including ownership of the Evaluation Board, are reserved by ADI. CONFIDENTIALITY. This Agreement and the Evaluation Board shall all be considered the confidential and proprietary information of ADI. Customer may not disclose or transfer any portion of the Evaluation Board to any other party for any reason. Upon discontinuation of use of the Evaluation Board or termination of this Agreement, Customer agrees to promptly return the Evaluation Board to ADI. ADDITIONAL RESTRICTIONS. Customer may not disassemble, decompile or reverse engineer chips on the Evaluation Board. Customer shall inform ADI of any occurred damages or any modifications or alterations it makes to the Evaluation Board, including but not limited to soldering or any other activity that affects the material content of the Evaluation Board. Modifications to the Evaluation Board must comply with applicable law, including but not limited to the RoHS Directive. TERMINATION. ADI may terminate this Agreement at any time upon giving written notice to Customer. Customer agrees to return to ADI the Evaluation Board at that time. LIMITATION OF LIABILITY. THE EVALUATION BOARD PROVIDED HEREUNDER IS PROVIDED “AS IS” AND ADI MAKES NO WARRANTIES OR REPRESENTATIONS OF ANY KIND WITH RESPECT TO IT. ADI SPECIFICALLY DISCLAIMS ANY REPRESENTATIONS, ENDORSEMENTS, GUARANTEES, OR WARRANTIES, EXPRESS OR IMPLIED, RELATED TO THE EVALUATION BOARD INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, TITLE, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS. IN NO EVENT WILL ADI AND ITS LICENSORS BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES RESULTING FROM CUSTOMER’S POSSESSION OR USE OF THE EVALUATION BOARD, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DELAY COSTS, LABOR COSTS OR LOSS OF GOODWILL. ADI’S TOTAL LIABILITY FROM ANY AND ALL CAUSES SHALL BE LIMITED TO THE AMOUNT OF ONE HUNDRED US DOLLARS ($100.00). EXPORT. Customer agrees that it will not directly or indirectly export the Evaluation Board to another country, and that it will comply with all applicable United States federal laws and regulations relating to exports. GOVERNING LAW. This Agreement shall be governed by and construed in accordance with the substantive laws of the Commonwealth of Massachusetts (excluding conflict of law rules). Any legal action regarding this Agreement will be heard in the state or federal courts having jurisdiction in Suffolk County, Massachusetts, and Customer hereby submits to the personal jurisdiction and venue of such courts. The United Nations Convention on Contracts for the International Sale of Goods shall not apply to this Agreement and is expressly disclaimed. ©2012 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. UG10385-0-2/12(0) Rev. 0 | Page 56 of 56
advertisement
Key Features
- High accuracy
- 3-phase energy metering
- Serial interfaces
- Flexible pulse outputs
- Sigma-delta analog-to-digital converters
- Digital integrator
- Reference circuitry
- Signal processing
- Total active and apparent energy
- RMS calculations
Frequently Answers and Questions
What is ADE7880?
The ADE7880 is a high accuracy, 3-phase electrical energy measurement IC with serial interfaces and three flexible pulse outputs.
What are the key features of ADE7880?
The ADE7880 incorporates second-order sigma-delta (Σ-Δ) analog-to-digital converters, a digital integrator, reference circuitry, and all of the signal processing required to perform the total (fundamental and harmonic) active and apparent energy measurements, rms calculations, and fundamental-only active and reactive energy measurements.
What kind of measurements can ADE7880 perform?
The ADE7880 can perform total (fundamental and harmonic) active and apparent energy measurements, rms calculations, and fundamental-only active and reactive energy measurements.