User Guide

User Guide
TABLE OF CONTENTS
1.Safety Instruction
2.Technical Specification
3.Lamp
4.How To Set The Unit
4.1 Control Panel
4.2 Main Function
4.3 Home Position Adjustment
5.How To Control The Unit
5.1 Master/Slave Built-In Preprogrammed Function
5.2 Easy Controller
5.3 iSolution Operation / DMX Controller
5.4 DMX 512 Configuration
5.5 DMX 512 Connection
6.Troubleshooting
User Guide
7.Maintenance and Cleaning
Please read these instructions carefully before use
1F
1. Safety Instruction
Warning
z
Please read carefully the instruction, which includes important
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
z
Never touch bulb with bare fingers, as it is very hot after using.
WARNING
z
Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
z
Please keep this User Guide for future consultation. If you sell the unit to another user,
z
Do not start on the unit without bulb enclosure or when housing is damaged.
be sure that they also receive this instruction booklet.
z
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
information about the installation, usage and maintenance.
z
Unpack and check carefully there is no transportation damage before using the unit.
z
Before operating, ensure that the voltage and frequency of power supply match the
damaged.
z
Do not look directly at the light while the bulb is on.
power requirements of the unit.
z
It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt any
z
The unit is for indoor use only. Use only in a dry location.
z
The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
repairs by yourself. In the unlikely event your unit may require service, please contact your
nearest dealer.
z
Disconnect main power before fuse/lamp replacement or servicing.
z
Replace fuse/lamp only with the same type.
Installation
z
Make sure there are no flammable materials close to the unit while operating, as it is fire
The unit should be mounted via its screw holes on the bracket (please refer to the drawing
hazard.
below). Always ensure that the unit is firmly fixed to avoid vibration and slipping while
z
z
z
Use safety chain when fixes this unit. Don’t handle the unit by taking its head only, but
operating. Always ensure that the structure to which you are attaching the unit is secure and
always by taking its base.
is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable
Maximum ambient temperature is Ta : 40℃. Don’t operate it where the temperature is
that can hold 12 times of the weight of the unit when installing the fixture.
higher than this.
The equipment must be fixed by professionals. And it must be fixed at a place where is out
Unit surface temperature may reach up to 85℃. Don’t touch the housing bare-hand
of the touch of people and has no one pass by or under it.
during its operation, and allow about 15 minutes to cool down before replacing bulb or
serving, as the unit could be very hot.
z
In the event of serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage
or malfunction. Please contact the nearest authorized technical assistance center.
Always use the same type spare parts.
z
Don’t connect the device to any dimmer pack.
z
Do not touch any wire during operation as there might be a hazard of electric shock.
2F
3F
8 Channels:
2. Technical Specification
Power supply
- AC 120V~60Hz or AC 230/240/250V~50/60Hz
Luminous intensity:
Channel 1 = Pan
Lamp
- MSD 250W/ NSD 250/2 W
Channel 2 = Tilt
Optical system
- High efficiency optical system
Channel 4 = Gobo
- High quality optical lens and dichroic colors
Channel 6 = Gobo Rotation
- Beam angle: 13°
Channel 7 = Prism/Prism
Channel 3 = Shutter
Channel 5 = Color
Shutter/Dimmer
Rotation/Dimmer
- Blackout, 0~100 smooth dimming and strobe speed variable(1~10 flashes per
second).
Color wheel
- Independent color wheel with 9 trapezoid dichroic colors plus white.
Channel 8 = Focus
Dimension: 428 x 384 x 466 mm (L x W x H)
Weight: 23 kg
- Color wheel rotates with variable speed, giving rainbow effect.
Gobo wheel
- Independent gobo wheel with 7 rotating, interchangeable gobos plus open: 5 metal
gobos, 2 glass gobos are included.
- Gobo wheel rotates with variable speed, giving shaking effect.
Effect Wheel
- Prism/Rotating Prism
Movement
- Pan: 540° in 2.8 second.
- Tilt: 270° in 1.6 second.
DMX Channels
- Standard DMX 512 signal addressing and can be controlled by any universal DMX
2.1. Inserting/Exchanging rotating gobos
controller.
DANGER!
16 Channels:
Install the gobos with the device switched off only.
Channel 1 = Pan
Channel 9 = Gobo
Channel 2 = Tilt
Channel 10 = Gobo Rotation
Channel 3 = Pan/Tilt Speed selection
Channel 11 = Prism
Open the cover by loosening the fastening screw at the sides of the cover.
Channel 4 = Dimmer
Channel 12 = Prism Rotation
If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be
Channel 5 = Shutter/Shaking
Channel 13 = Focus
exchanged, remove the fixation ring with an appropriate tool. Remove the gobo and insert
Channel 6 = Color
Channel 14 = Pan 16 bit
the new gobo. Press the fixation-ring together and insert it in the front of the gobo.
Channel 7 = No Function
Channel 15 = Tilt 16 bit
Channel 8 = No Function
Channel 16 = Reset/Lamp on/off
4F
Unplug from mains before changing gobos!
5F
4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do
not use the lamp any longer than its specified life.
5. Make sure the lamp is located in the center of the reflector for the best spot.
4. How To Set The Unit
4.1. Control Panel
CAUTION!
Never unscrew the screws of the rotating gobo as the ball bearing
will otherwise be opened!
3. Lamp
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.
WARNING
Because of its high internal pressure, there might be a risk that the Discharge lamp
would explode during operation. The lamp emits intense UV radiation which is harmful
Display
to the eyes and skin. The high luminance of the arc can cause severe damage to the
To show the various menus and the selected functions
retina if looks directly at the lamp.
LED
DMX
On
DMX input present
MASTER
On
Master mode
SLAVE
On
Slave mode
SOUND
Flashing
Sound activation
2. Do not touch the bulb with bare hands. If this
MENU
To select the programming functions
happens, clean the lamp with denatured
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
MSD 250W/ NSD 250/2 W
1. Always switch off the main supply and never
handle the lamp or luminaire when it is hot.
alcohol and wipe it with a lint free cloth
before installation.
3. The lamp generates UV radiation. Never
operate the lamp without appropriate shielding.
6F
Button
Remote controller input
By connecting to CA-8 to control the unit for Stand by, Function, and Mode function.
7F
Sensitivity
DMX512 Address Setting
To adjust the sound-input sensitivity
DMX input/output
Press the MENU button up to when the
For DMX512 operation, use 3-pin XLR plug cable to link the unit together.
is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press the ENTER button to setup or automatically
4.2. Main Function
return to the main functions without any change after 8 seconds. To go back to the functions
To select any of the pre-set functions, press the MENU button up to when the required one
without any change press the MENU button again.
is shown on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected,
press the ENTER button to setup or it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the
MENU button. The main functions are shown below:
Channel Mode
is shown on the display. Pressing ENTER
Press the MENU button up to when the
button and the display will blink. Use DOWN and UP button to select the
(16
(8 Channel) mode. Once the mode has been selected, press the
Channel ) or
ENTER button to setup or automatically return to the main functions without any change
after 8 seconds. To go back to the functions without any change press the MENU button
again.
Show Mode
Press the MENU button up to when the
is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(show 1) or
(show 2) or
(show 3) or
(show 4) mode. Once the
mode has been selected, press the ENTER button to setup or automatically return to the
main functions without any change after 8 seconds. To go back to the functions without any
change press the MENU button again.
Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°.
Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°.
Show 3 mode - Fixture is placed on the speaker, The spot is always projecting
to the audience’s direction; i.e in front of the stage. Pan movement angle ( left to
right to left ): 160°. Tilt movement angle:
90° ( 60° above horizon; 30° below
horizon).
Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in
front of the stage. Pan movement angle (left to right to left) :160°.
movement angle: 90° ( vertically, front 75°; back 15° ) .
8F
9F
Tilt
button to setup or automatically return to the main functions without any change after 8
Slave Mode
seconds. To go back to the functions without any change press the MENU button again.
Press the MENU button up to when the
is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the
or
Display Inversion
(normal)
(2 light show) mode. Once the mode has been selected, press the ENTER
button to setup or automatically return to the main functions without any change after 8
seconds. To go back to the functions without any change press the MENU button again.
It is good for you to install the unit on the floor or under ceiling. Press the MENU button up to
is blinking on the display. Use the ENTER button to change to the mode
when the
(display inversion), It will automatically store after 8 seconds. Or press the ENTER
button again return to the mode
Blackout Mode
the MENU button.
is shown on the display. Pressing ENTER
Press the MENU button up to when the
button and the display will blink. Use DOWN and UP button to select the
blackout) or
(display normal). To go back to the functions press
(yes
Display normal mode for the fixture putting on the floor.
Display inversion mode for the fixture fixing under ceiling.
(no blackout) mode. Once the mode has been selected, press the
ENTER button to setup or automatically return to the main functions without any change
Focus Adjust
after 8 seconds. To go back to the functions without any change press the MENU button
Press the MENU button up to when the
again.
button, the unit will focus on tilt 90°, and then the unit will focus on tilt 0°, pan 0°, pan 90°,
is blinking on the display. Pressing ENTER
pan 180°, pan 270° in every pressing ENTER button. To go back to the functions press the
Pan Inversion
MENU button again.
is shown on the display. Pressing ENTER
Press the MENU button up to when the
button and the display will blink. Use DOWN and UP button to select the
or
(normal)
(pan inversion) mode. Once the mode has been selected, press the ENTER
Self-Test
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
button to setup or automatically return to the main functions without any change after 8
button and the unit will run self-test by built-in program. To go back to the functions press the
seconds. To go back to the functions without any change press the MENU button again.
MENU button again.
Tilt Inversion
Ambient temperature of lamp
Press the MENU button up to when the
is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the
or
(normal)
(tilt inversion) mode. Once the mode has been selected, press the ENTER
Press the MENU button up to when the
is blinking on the display. Pressing
ENTER button and the ambient temperature of lamp will show on the display. To go back to
the functions press the MENU button again.
button to setup or automatically return to the main functions without any change after 8
seconds. To go back to the functions without any change press the MENU button again.
Fixture Hours
Press the MENU button up to when the
Led Display
is blinking on the display. Pressing ENTER
button and the display will show the number of working hours of the unit. To go back to the
Press the MENU button up to when the
is showing on the display. Pressing
functions press the MENU button again.
ENTER button and the display will blink. Use DOWN and UP button to select the
(Led on) or
(Led off) mode. Once the mode has been selected, press the ENTER
10F
11F
Lamp ON/OFF
Pan offset
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the
(Lamp on)
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
is shown on the display. Pressing ENTER button and the display
(Lamp off) mode. Once the mode has been selected, press the ENTER button
will blink. Use DOWN and UP button to adjust the pan home position. Once the position has
to setup or automatically return to the main functions without any change after 8 seconds. To
been selected, press the ENTER button to setup or automatically return to the offset
go back to the functions without any change press the MENU button again.
functions without any change press the MENU button again, To go back to the main
or
functions without any change after 8 seconds.
Reset
is blinking on the display. Pressing ENTER
Press the MENU button up to when the
button and all channels of the unit will return to their standard position. To go back to the
functions press the MENU button again.
Tilt offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the tilt home position. Once the position has
DMX RESET :
Set DMX value of channel 8 and channel 16 to 255, then all channels of the unit will return to
been selected, press the ENTER button to setup or automatically return to the offset
their standard home position.
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
4.3 Home Position Adjustment
Press MENU button for at least 5 seconds into offset mode to adjust the home position,
when you want to adjust pan and tilt home position, you should be run
mode first ,
the functions are shown below:
Gobo offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the gobo home position. Once the gobo has
been selected, press the ENTER button to setup or automatically return to the offset
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
Color offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
Focus Adjust
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the color home position. Once the color has
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
been selected, press the ENTER button to setup or automatically return to the offset
is shown on the display. Pressing ENTER button, the unit will focus
functions without any change press the MENU button again, To go back to the main
up to when the
on the center position. Use DOWN and UP button to adjust focus, this settings only for offset
functions without any change after 8 seconds.
mode to adjust home position. To go back to the main functions without any change after 8
seconds
12F
13F
5. How To Control The Unit
Stand by
You can operate the unit in three ways:
1. By master/slave built-in preprogrammed function
Function
Blackout the unit
Strobe
1. Color sync. strobe
2. Sync. strobe
3. Two-light strobe
X/Y moving show pattern Gobo/Color selection
1.Hold on for gobo
selection
( Show 1 ~ Show 4 )
selection
Please refer to 4.2. Main 2.Press for color change
Functions- Show mode
X/Y moving setting
1.Pan position
2.Tilt position
3.Dimmer
First set Master unit, then set
Slave units’ position
Sound 1
(LED off )
Sound 2
(LED slow blinking)
Position/ Latch
(LED fast blinking)
2. By easy controller
3. By IL-0824 ( only for setting in 8 channel mode, please refer to the user guide of
Mode
iLead controller ) or by universal DMX controller
Slow/Sound 3
(LED on)
No need to turn the unit off when you change the DMX address, as new DMX address
setting will be effected at once. Every time you turn the unit on, it will show I250 on the
display and move all the motors to their ‘home’ position and you may hear some noises for
about 20 seconds. After that the unit will be ready to receive DMX signal or run the built-in
5.3.1 iSolution Operation
·Consistent DMX configuration enable iMove to be linked with iRock and iShow together
and controlled at the same time.
·DMX address can be set remotely by iLead controller ( please refer to the user manual of
programs.
iLead controller ). No need to calculate the DMX channels of each fixture in the chain.
·Automatic switching between DMX function and built-in stand alone programs.
5.1. Master/Slave Built-In Preprogrammed Function
You can select blackout mode
in
(yes blackout) or
(no blackout)
5.3.2 DMX Controller
mode while the unit is turned on. By linking the units in master/slave connection, the first unit
If you use a universal DMX controller to control the units, you have to set DMX address from
will control the other units to give an automatic, sound activated, synchronized light show.
1 to 512 channel so that the units can receive DMX signal.
This function is good when you want an instant show. You have to select show (show 1, 2, 3,
Press the MENU button up to when the
4) modes by easy controller . Its DMX input jack will have nothing plugged into it, and Its
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
master LED will be constantly on and sound LED will flash to the music. The other units will
Once the address has been selected, press and keep ENTER button pressed up to when
have to set in slave mode
the display stops blinking or storing automatically 8 seconds later. To go back to the
and select
(normal) or
(2 light show)
is shown on the display. Pressing ENTER
mode, Their DMX cables plugged into the DMX input jacks (daisy chain) and the slave LED
functions without any change press the MENU button again.
lights will constantly on.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
2-light show
In
(slave mode),
means the unit works normally and
2-light show. In order to create a great light show, you can set
to get contrast movement to each other, even if you have two units only.
means
16 Channels:
on the second unit
8 Channels:
You have to set the fixture DMX address in 8 channels mode when you use IL-0824
5.2. Easy Controller
The easy remote control is used only in master/slave mode. By
controller. DMX address can be set remotely by IL-0824 controller. No need to calculate the
connecting to the 1/4” microphone jack of the first unit, you will find
DMX channels of each fixture in the chain.
that the remote control on the first unit will control all the other units for
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Stand by, Function and Mode.
8 Channels:
14F
15F
5.4. DMX 512 Configuration
i.) For DMX reset, put DMX value of CH-8 & CH-16 to 255, the unit will reset after about five
seconds.
For lamp on, put DMX value of CH-8 to 247 & CH-16 to 255.
For lamp off, put DMX value of CH-8 to 239 & CH-16 to 255.
ii.) For color sound activated, put DMX value of CH-6 to 248-255.
For gobo sound activated, put DMX value of CH-9 to 248-255.
16F
17F
5.5. DMX512 Connection
6. Troubleshooting
The DMX512 is widely used in intelligent lighting control, with a maximum of 512
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
channels.
A. The unit does not work, no light and the fan does not work
1.
Check the connect power and main fuse.
2.
Measure the mains voltage on the main connector.
3.
Check the power on LED.
B. Not responding to DMX controller
1.
DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2.
If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3.
If you have intermittent DMX signal problems, check the pins on connectors or on PCB of
the unit or the previous one.
4.
Try to use another DMX controller.
5.
Check to see if the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
1.
If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pin adapter.
C. Some units don’t respond to the easy controller
2.
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm
1. You may have a break in the DMX cabling. Check the LED for the response of the master/
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it
in the DMX-output of the last unit.
3.
Connect the unit together in a “daisy chain” by XLR plug cable from the output of the
unit to the input of the next unit. The cable cannot be branched or split to a “Y” cable.
4.
5.
slave mode signal.
2. Wrong DMX address in the unit. Set the proper address.
D. No response to the sound
DMX512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or
1.
Make sure the unit is not receiving DMX signal.
corroded connectors can easily distort the signal and shut down the system.
2.
Check microphone to see if it is good by tapping the microphone.
The DMX output and input connectors are pass-through to maintain the DMX circuit,
E. One of the channels is not working well
when power is disconnected to the unit.
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
Each lighting unit needs to have an address set to receive the data sent by the
2. The motor’s drive IC on the PCB might be out of condition.
controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6.
The end of the DMX512 system should be terminated to reduce signal errors.
7.
3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
18F
F. The lamp is cutting out intermittently
1. The lamp is not working well. Check the main voltage either too high or too low.
2. Internal temperature may be too high. Check and if necessary replace the fan on the
head.
19F
F. If The tilt belt is broken
G. If The pan belt is broken
1. Turn off the main power.
1. Turn off the main power.
2. Unscrew all the screws (A) and open the base-housing cover (B).
2. Unscrew all the screws (A) and open the right arm cover (B).
3. Unscrew all the screws (C) and open the arm cover (D).
3. Unscrew the screws (C), the screws (D) and screws (E) that fix the bridge.
4. Unplug all the connect wires that from the arm to the bottom.
4. Change a new belt (F). Please adjust the tension of the belt properly. Note: do not fix
belt too tight as it is easy to rupture.
5. Unscrew the screws (E) and remove the fixture head.
5. Reverse the procedures from point 3 to 2.
6. Loose the screws (F), then loose the screws (G).
7. Change a new belt (H) , put the belt around the axis gear and motor gear.
D
F
8. Screwed the screws (G), install the new belt and adjust the belt tension properly. Note: do
E
not fix belt too tight as it is easy to rupture.
9. Plug all the connect wires back that form the bottom to the arm.
10. Reverse the procedures from point 5 to point 2.
A
C
B
C
D
C
D
C
A
B
F
E
B
A
H
C
A
G
20F
21F
Pay attention to the belt tension when install the belt.
Please refer to the photos below:
7. Maintenance and Cleaning
Maintenance:
Anti-interference plate
F
Ignitor
G
Ballast
Photo 1
A. As the pictures shown above, if the cable or cable joints turned yellow or black, please
replace the cable or cable joints immediately.
B. Do maintain the fixtures every two months and make sure that all the screws and
terminals have been locked firmly to make sure the normal performance of the fixtures.
Negligence of maintenance would cause malfunction of the fixture.
Cleaning:
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
y Clean with soft cloth using normal glass cleaning fluid.
y Always dry the parts carefully.
Adjust belt tension through loose the screw
y Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
Photo 2
22F
23F
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN 60598-1: 2004
IEC 60598-1:2003+ corrigendum 2004
Part 1:General requirements and test