Below you will find brief information for MSZ-SF25VE, MSZ-SF35VE, MSZ-SF42VE, MSZ-SF50VE, MUZ-SF25VE(H), MUZ-SF35VE(H), MUZ-SF42VE(H), MUZ-SF50VE(H). This manual contains instructions on how to install your new split-system air conditioner. Each step is explained in detail, with diagrams to illustrate the process. You will find information on selecting the right installation location, connecting wires and refrigerant pipes, as well as performing purging procedures, leak tests, and test runs.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Mitsubishi Electric MSZ-SF25VE, MSZ-SF35VE, MSZ-SF42VE, MSZ-SF50VE Installation Manual | Manualzz

SPLIT-TYPE AIR CONDITIONERS

INSTALLATION MANUAL

JG79R241H01

Model names are indicated in 1-3.

When installing multi units, refer to the installation manual of the multi unit for outdoor unit installation.

Required Tools for Installation

Phillips screwdriver

Level

Scale

Utility knife or scissors

65 mm hole saw

Torque wrench

Wrench (or spanner)

4 mm hexagonal wrench

Flare tool for R410A

Gauge manifold for R410A

Vacuum pump for R410A

Charge hose for R410A

Pipe cutter with reamer

1. BEFORE INSTALLATION

1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

• Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.

• Be sure to observe the warnings and cautions specified here as they include important items related to safety.

• After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.

WARNING

(Could lead to death, serious injury, etc.)

N Do not install the unit by yourself (user).

Incomplete installation could cause fire, electric shock, injury due to the unit falling, or leakage of water. Consult the dealer from whom you purchased the unit or a qualified installer.

N Perform the installation securely referring to the installa- tion manual.

Incomplete installation could cause fire, electric shock, injury due to the unit falling, or leakage of water.

N When installing the unit, use appropriate protective equip- ment and tools for safety.

Failure to do so could cause injury.

N Install the unit securely in a place which can bear the weight of the unit.

If the installation location cannot bear the weight of the unit, the unit could fall causing injury.

N rienced electrician, according to the installation manual.

Be sure to use an exclusive circuit. Do not connect other electrical appliances to the circuit.

If the capacity of the power circuit is insufficient or there is incomplete electrical work, it could result in a fire or an electric shock.

N Earth the unit correctly.

Do not connect the earth to a gas pipe, water pipe, lightning rod, or telephone earth. Defective earthing could cause electric shock.

N Do not damage the wires by applying excessive pressure with parts or screws.

Damaged wires could cause fire or electric shock.

N indoor P.C. board or wiring works.

Failure to do so could cause electric shock.

N Use the specified wires to connect the indoor and outdoor units securely and attach the wires firmly to the terminal block connecting sections so the stress of the wires is not applied to the sections. Do not extend the wires, or use intermediate connection.

Incomplete connecting and securing could cause fire.

N may leak.

If gas leaks and accumulates in the area around the unit, it could cause an explosion.

N Do not use intermediate connection of the power cord or the extension cord and do not connect many devices to one AC outlet.

It could cause a fire or an electric shock due to defective contact, defective insulation, exceeding the permissible current, etc.

N the installation work.

The use of defective parts could cause an injury or leakage of water due to a fire, an electric shock, the unit falling, etc.

N make sure that there is no dust, clogging, or loose parts in both the outlet and the plug. Make sure that the power supply plug is pushed completely into the outlet.

If there is dust, clogging, or loose parts on the power supply plug or the outlet, it could cause electric shock or fire. If loose parts are found on the power supply plug, replace it.

N Attach the electrical cover to the indoor unit and the service panel to the outdoor unit securely.

If the electrical cover of the indoor unit and/or the service panel of the outdoor unit are not attached securely, it could result in a fire or an electric shock due to dust, water, etc.

N When installing, relocating, or servicing the unit, make sure that no substance other than the specified refrigerant

(R410A) enters the refrigerant circuit.

Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury.

The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction, or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

N refrigerant leaks during installation, ventilate the room.

If refrigerant comes in contact with a fire, harmful gas could be generated. Refrigerant leakage may cause suffocation.

Provide ventilation in accordance with EN378-1.

N lation has been completed.

If refrigerant gas leaks indoors, and comes into contact with the flame of a fan heater, space heater, stove, etc., harmful substances will be generated.

N tion.

The pressure of R410A is 1.6 times more than R22. Not using appropriate tools or materials and incomplete installation could cause the pipes to burst or injury.

N before disconnecting the refrigerant pipes.

If the refrigerant pipes are disconnected while the compressor is running and the stop valve is open, air could be drawn in and the pressure in the refrigeration cycle could become abnormally high. This could cause the pipes to burst or injury.

N When installing the unit, securely connect the refrigerant pipes before starting the compressor.

If the compressor is started before the refrigerant pipes are connected and when the stop valve is open, air could be drawn in and the pressure in the refrigeration cycle could become abnormally high. This could cause the pipes to burst or injury.

N this manual.

If fastened too tight, a flare nut may break after a long period and cause refrigerant leakage.

N wiring regulations.

CAUTION

(Could lead to serious injury in particular environments when operated incorrectly.)

N Install an earth leakage breaker depending on the instal- lation place.

If an earth leakage breaker is not installed, it could cause electric shock.

N Perform the drainage/piping work securely according to the installation manual.

If there is defect in the drainage/piping work, water could drop from the unit, soaking and damaging household goods.

N Do not touch the air inlet or the aluminum fins of the outdoor unit.

This could cause injury.

N Do not install the outdoor unit where small animals may live.

If small animals enter and touch the electric parts inside the unit, it could cause a malfunction, smoke emission, or fire.

Also, advise user to keep the area around the unit clean.

1-2. SELECTING THE INSTALLATION LOCATION

INDOOR UNIT

• Where airflow is not blocked.

• Where cool air spreads over the entire room.

• Rigid wall without vibration.

• Where it is not exposed to direct sunshine. Do not expose to direct sunshine also during the period following unpacking to before use.

• Where easily drained.

• At a distance 1 m or more away from your TV and radio.

Operation of the air conditioner may interfere with radio or

TV reception. An amplifier may be required for the affected device.

• In a place as far away as possible from fluorescent and incandescent lights (so the infrared remote control can operate the air conditioner normally).

• Where the air filter can be removed and replaced easily.

REMOTE CONTROLLER

• Where it is easy to operate and easily visible.

• Where children cannot touch it.

• Select a position about 1.2 m above the floor and check that signals from the remote controller are surely received by the indoor unit from that position (‘beep’ or ‘beep beep’ receiving tone sounds). After that, attach remote controller holder to a pillar or wall and install wireless remote controller.

1-3. SPECIFICATIONS

Note:

In rooms where inverter type fluorescent lamps are used, the signal from the wireless remote controller may not be received.

Note:

It is advisable to make a piping loop near outdoor unit so as to reduce vibration transmitted from there.

OUTDOOR UNIT

• Where it is not exposed to strong wind.

• Where airflow is good and dustless.

• Where rain or direct sunlight can be avoided as much as possible.

• Where neighbours are not annoyed by operation sound or hot air.

• Where rigid wall or support is available to prevent the increase of operation sound or vibration.

• Where there is no risk of combustible gas leakage.

• When installing the unit at a high level, be sure to secure the unit legs.

• Where it is at least 3 m away from the antenna of TV set or radio. Operation of the air conditioner may interfere with radio or TV reception in areas where reception is weak. An amplifier may be required for the affected device.

• Install the unit horizontally.

• Please install it in an area not affected by snowfall or blowing snow. In areas with heavy snow, please install a canopy, a pedestal and/or some baffle boards.

Note:

When operating the air conditioner in low outside temperature, be sure to follow the instructions described below.

• Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to wind.

• To prevent exposure to wind, install the outdoor unit with its air inlet side facing the wall.

• To prevent exposure to wind, it is recommended to install a baffle board on the air outlet side of the outdoor unit.

Avoid the following places for installation where air conditioner trouble is liable to occur.

• Where flammable gas could leak.

• Where there is much machine oil.

• Where oil is splashed or where the area is filled with oily smoke (such as cooking areas and factories, in which the properties of plastic could be changed and damaged).

• Salty places such as the seaside.

• Where sulfide gas is generated such as a hot spring.

• Where there is high-frequency or wireless equipment.

• Where there is emission of high levels of VOCs, including phthalate compounds, formaldehyde, etc., which may cause chemical cracking.

(SF25, 35, 42/SF50)

Model Power supply *1 Wire specifications *2

Pipe size

(thickness *3, *4) Pipe length and height difference

Indoor unit Outdoor unit Rated Voltage Frequency

Breaker capacity

Power supply

Indoor/outdoor connecting wire

Gas / Liquid

Max. pipe length

Max. height difference

20/30 m

12/15 m

MSZ-SF25VE

MSZ-SF35VE

MSZ-SF42VE

MUZ-SF25VE(H)

MUZ-SF35VE(H)

MUZ-SF42VE(H)

MSZ-SF50VE MUZ-SF50VE(H)

230 V 50 Hz

10 A

16 A

3-core

1.0 mm 2

3-core

2.0 mm 2

4-core

1.0 mm 2

ø9.52 / 6.35 mm

(0.8 mm)

ø12.7 / 6.35 mm

(0.8 mm)

Max. number of bends *5, *6

Refrigerant adjustment A *7

Insulation thickness *8, *9

10

30/20 g/m

8 mm

*1 Connect to the power switch which has a gap of 3 mm or more when open to interrupt the source power phase. (When the power switch is shut off, it must interrupt all phases.)

*2 Use wires in conformity with design 60245 IEC 57.

*3 Never use pipes with thickness less than specified. The pressure resistance will be insufficient.

*4 Use a copper pipe or a copper-alloy seamless pipe.

*5 Be careful not to crush or bend the pipe during pipe bending.

*6 Refrigerant pipe bending radius must be 100 mm or more.

*7 If pipe length exceeds 7 m, additional refrigerant (R410A) charge is required. (No additional charge is required for pipe length less than 7 m.)

Additional refrigerant = A × (pipe length (m) – 7)

*8 Insulation material : Heat resisting foam plastic 0.045

specific gravity

*9 Be sure to use the insulation of specified thickness. Excessive thickness may cause incorrect installation of the indoor unit and insufficient thickness may cause dew drippage.

1-4. INSTALLATION DIAGRAM

ACCESSORIES

Check the following parts before installation.

<Indoor unit>

1 (1) Installation plate

(2)

Installation plate fixing screw

4 × 25 mm

(3) Remote controller holder

(4)

Fixing screw for (3) 3.5 × 16 mm

(Black)

5

1

2

(5) Battery (AAA) for (6)

(6) Wireless remote controller

(7)

Felt tape

(For left or left-rear piping)

2

1

1

<Outdoor unit>

(8) Drain socket (VE type only) 1 more for left and left back piping (using

107.5 mm or more

117.5

Be sure to use wall hole sleeve (C) to prevent indoor/outdoor connecting wire (A) from contacting metal parts in the wall and to prevent damage by rodents in case the wall is hollow.

Wall hole sleeve (C)

Cut off the extra length.

Wall hole cover (D)

Seal the wall hole gap with putty (H).

Fix the pipe to wall with pipe fixing band

(E).

Pipe fixing band

(E)

Fixing screw

(F)

PARTS TO BE PROVIDED

AT YOUR SITE

(A) Indoor/outdoor unit connecting wire* 1

(B) Extension pipe 1

(C) Wall hole sleeve

(D) Wall hole cover

(E) Pipe fixing band

(F) Fixing screw for (E) 4 × 20 mm

1

1

2 to 5

2 to 5

(G) Piping tape

(H) Putty

1

1

(I)

Drain hose

(or soft PVC hose, 15 mm inner diameter or hard PVC pipe VP16)

1 or 2

(J) Refrigeration oil

(K) Power supply cord*

1

1

0.5 mm or

(SF25, 35, 42/SF50)

100/500 mm or more

100 mm or more

100 mm or more

After the leak test, apply insulating material tightly so that there is no gap.

Outdoor unit installation (SF25, 35, 42/SF50)

800/840 mm

150/175 mm

500 mm

Air inlet

When the piping is to be attached to a wall containing metals (tin plated) or metal netting, use a chemically treated wooden piece 20 mm or thicker between the wall and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping.

To use existing piping, perform COOL operation for

30 minutes and pump down before removing the old air conditioner. Remake flare according to the dimension for new refrigerant.

Air outlet

2/4-10 mm × 21 mm slot 40 mm

Drain piping for outdoor unit

<VE type only>

• Provide drain piping before indoor and outdoor piping connection.

• Connect drain hose (I) I.D.15 mm as shown in the illustration.

• Make sure to provide drain piping with a downhill grade for easy drain flow.

Note:

Install the unit horizontally.

Do not use drain socket (8) in cold regions. Drain may freeze and make the fan stop.

The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the grounds from being wet by drain water or damaged by frozen drain water.

* Note:

Place indoor/outdoor unit connecting wire (A) and power supply cord (K) at least 1 m away from the

TV antenna wire.

Units should be installed by licensed contractor according to local code requirements.

(SF25, 35, 42/SF50)

200/500 mm or more

350 mm or more

Appearance of the outdoor unit may differ from some models.

2. INDOOR UNIT INSTALLATION

2-1. FIXING OF INSTALLATION PLATE

• Find a structural material (such as a stud) in the wall and fix installation plate (1) horizontally by tightening the fixing screws (2) firmly.

• To prevent installation plate (1) from vibrating, be sure to install the fixing screws in the holes indicated in the illustration. For added support, fixing screws may also be installed in other holes.

• When the knockout is removed, apply vinyl tape to the knockout edges to prevent damaging the wires.

• When bolts recessed in the concrete wall are to be utilized, secure installation plate (1) using 11 × 20 · 11 × 26 oval hole (450 mm pitch).

• If the recessed bolt is too long, change it for a shorter one available in the market.

4) Loosen terminal screw, and connect first the earth wire, then indoor/outdoor unit connecting wire (A) to the terminal block. Be careful not to make mis-wiring. Fix the wire to the terminal block securely so that no part of its core is appeared, and no external force is conveyed to the connecting section of the terminal block.

5) Firmly tighten the terminal screws to prevent them from loosening. After tightening, pull the wires lightly to confirm that they do not move.

6) Secure indoor/outdoor unit connecting wire (A) and the earth wire with the VA clamp.

Never fail to hook the left claw of the VA clamp. Attach the VA clamp securely.

Terminal block

2-2. WALL HOLE DRILLING

1) Determine the wall hole position.

2) Drill a ø65 mm hole. The outdoor side should be

5 to 7 mm lower than the indoor side.

3) Insert wall hole sleeve (C).

Wall

5-7 mm

35 mm

15 mm

Fixing screw

Ceiling

Outdoor side

72 mm or more

115 mm or more for left and left back piping (using spacer)

Indoor/outdoor unit connecting wire (A)

Installation plate (1)

Level

Wall

107.5

mm or more

117.5

mm or more

Wall

Fixing screw (2)

Position of the union joints

(110 mm longer for - EN1)

Insert the scale. *

Align the scale with the line. *

Center of

ø65 mm hole

* Same for left hole.

2-3. CONNECTING WIRES FOR INDOOR UNIT

You can connect indoor/outdoor lead wire without removing the front panel.

1) Open the front panel.

2) Remove VA clamp.

3) Pass indoor/outdoor unit connecting wire (A) from the back of the indoor unit and process the end of the wire.

• For future servicing, give extra length to the connecting wires.

• Make earth wire a little longer than others.

(More than 60 mm)

• Do not fold the excess wire, or cram it into small space. Take caution not to damage the wires.

• Be sure to attach each screw to its correspondent terminal when securing the cord and/or the wire to the terminal block.

Note: Do not place the wires between the indoor unit and the installation plate (1).

Damaged wire could cause heat generation or fire.

Earth wire

(green/yellow)

Indoor/outdoor unit connecting wire (A)

Indoor terminal block

Outdoor terminal block

PIPE FORMING AND DRAIN PIPING

Pipe Forming

• Place the drain hose below the refrigerant piping.

• Make sure that the drain hose is not heaved or snaked.

• Do not pull the hose when applying the tape.

• When the drain hose passes the room, be sure to wrap insulation material (obtainable at a store) around it.

Liquid pipe

Gas pipe

Indoor/outdoor unit connecting wire (A)

Felt tape (7)

Piping tape (G)

Rear, right, or downward piping

1) Put the refrigerant piping and the drain hose together, then firmly apply piping tape (G) from the end.

Cut off in case of right piping.

2) Insert the piping and the drain hose into the wall hole sleeve (C), and hook the upper part of the

Cut off in case of downward piping.

indoor unit on the installation plate (1).

3) Check if the indoor unit is hooked securely on the installation plate (1) by moving the unit to left and right.

4) Thrust the lower part of the indoor unit into the installation plate (1).

Drain Piping

• If the extension drain hose has to pass through a room, be sure to wrap it with commercially sold insulation.

• The drain hose should point downward for easy drain flow. (Fig. 1)

• If the drain hose provided with the indoor unit is too short, connect it with drain hose

(I) that should be provided at your site. (Fig. 2)

• When connecting the drain hose to the hard vinyl chloride pipe, be sure to insert it securely into the pipe. (Fig. 3)

Drain hose

Downward slope

70 cm or more

Soft hose

I.D. 15 mm

Different diameter joint

Fig. 1 Fig. 2

Do not make drain piping as shown below.

Water leakage

Do not raise

Water leakage drain water

Air

Waving

Water leakage

Drain hose

Hard vinyl chloride pipe I.D. 30 mm

Insert securely

Fig. 3

Ditch

At least

50 mm gap

Left or left-rear piping

Note:

Be sure to reattach the drain hose and the drain cap in case of left or left-rear piping.

Otherwise, it could cause drops of water to drip down from the drain hose.

Piping tape (G)

Felt tape (7)

1) Put the refrigerant piping and the drain hose together, then firmly apply felt tape (7) from the end.

Felt tape (7) overlap width should be 1/3 the tape width.

Use a bandage stopper at the end of felt tape (7).

2) Pull out the drain cap at the rear right of the indoor unit.

(Fig. 1)

• Hold the convex section at the end and pull the drain cap.

3) Pull out the drain hose at the rear left of the indoor unit.

(Fig. 2)

• Hold the claw marked by the arrows and pull out the drain hose forward.

4) Put the drain cap into the section to which the drain hose is to be attached at the rear of the indoor unit.

(Fig. 3)

• Insert not sharp-edged tools such as screwdrivers into the hole at the end of the cap and insert the cap fully into the drain pan.

5) Insert the drain hose fully into the drain pan at the rear right of the indoor unit. (Fig. 4)

• Check if the hose is hooked securely to the projection of its inserting part at the drain pan.

6) Insert the drain hose into wall hole sleeve (C), and hook the upper part of indoor unit on installation plate (1). Then, move the indoor unit completely to the left in order to make placing the piping in the back space of the unit easier.

7) Cut out a piece of cardboard from the shipping box, roll it up, hook it onto the back rib, and use it as a spacer to lift the indoor unit. (Fig. 5)

8) Connect the refrigerant piping with the extension pipe

(B).

9) Thrust the lower part of the indoor unit into the installation plate (1).

Cut off in case of left piping.

Drain cap

Fig. 1

Drain cap

Drain hose

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Drain cap

Drain hose

3. OUTDOOR UNIT INSTALLATION

3-1. CONNECTING WIRES FOR OUTDOOR UNIT

1) Open the service panel.

2) Loosen terminal screw, and connect indoor/outdoor unit connecting wire (A) from the indoor unit correctly on the terminal block. Be careful not to make mis-wiring. Fix the wire to the terminal block securely so that no part of its core is appeared, and no external force is conveyed to the connecting section of the terminal block.

3) Firmly tighten the terminal screws to prevent them from loosening. After tightening, pull the wires lightly to confirm that they do not move.

4) Connect power supply cord (K).

5) Fix indoor/outdoor unit connecting wire (A) and power supply cord (K) with the cord clamp.

6) Close the service panel securely.

35 mm

15 mm

Lead wire

Terminal block • Make earth wire a little longer than others. (More than 100 mm)

• For future servicing, give extra length to the connecting wires.

• Be sure to attach each screw to its correspondent terminal when securing the cord and/or the wire to the terminal block.

Indoor/outdoor unit connecting wire (A)

Cord clamp

<SF50>

Power supply cord (K)

Cord clamp

<SF25, 35, 42>

3-2. FLARING WORK

1) Cut the copper pipe correctly with pipe cutter.

(Fig. 1, 2)

2) Completely remove all burrs from the cut cross section of pipe. (Fig. 3)

• Put the end of the copper pipe to downward direction as you remove burrs in order to avoid to let burrs drop in the piping.

3) Remove flare nuts attached to indoor and outdoor units, then put them on pipe having completed burr removal.

(Not possible to put them on after flaring work.)

4) Flaring work (Fig. 4, 5). Firmly hold copper pipe in the dimension shown in the table. Select A mm from the table according to the tool you use.

5) Check

• Compare the flared work with Fig. 6.

• If flare is noted to be defective, cut off the flared section and do flaring work again.

Burr

Copper pipe

Spare reamer

Pipe cutter

Fig. 3

Good

Copper pipe

Fig. 1

No good

Tilted Uneven Burred

Fig. 2

Flaring tool

Wing nut type

Fig. 4

Smooth all around

Inside is shining without any scratches.

Die

Flare nut

Pipe diameter

(mm)

ø 6.35 (1/4”)

ø 9.52 (3/8”)

ø12.7 (1/2”)

ø15.88 (5/8”)

Copper pipe

Fig. 5

Even length all around Fig. 6

Nut

(mm)

A (mm)

Clutch type tool for R410A

Clutch type tool for R22

17

22

26

29

0 to 0.5

1.0 to 1.5

Tightening torque

Wing nut type tool for R22

N•m kgf•cm

1.5 to 2.0

2.0 to 2.5

13.7 to 17.7 140 to 180

34.3 to 41.2 350 to 420

49.0 to 56.4 500 to 575

73.5 to 78.4 750 to 800

3-3. PIPE CONNECTION

• Fasten flare nut with a torque wrench as specified in the table.

• When fastened too tight, flare nut may break after a long period and cause refrigerant leakage.

• Be sure to wrap insulation around the piping. Direct contact with the bare piping may result in burns or frostbite.

Indoor unit connection

Connect both liquid and gas pipings to indoor unit.

• Apply a thin coat of refrigeration oil (J) on the seat surface of pipe.

• For connection, first align the center, then tighten the first 3 to 4 turns of flare nut.

• Use tightening torque table above as a guideline for indoor unit side union joint section, and tighten using two wrenches. Excessive tightening damages the flare section.

Outdoor unit connection

Connect pipes to stop valve pipe joint of the outdoor unit in the same manner applied for indoor unit.

• For tightening, use a torque wrench or spanner and use the same tightening torque applied for indoor unit.

WARNING

When installing the unit, securely connect the refrigerant pipes before starting the compressor.

3-4. INSULATION AND TAPING

1) Cover piping joints with pipe cover.

2) For outdoor unit side, surely insulate every piping including valves.

3) Using piping tape (G), apply taping starting from the entry of outdoor unit.

• Stop the end of piping tape (G) with tape (with adhesive agent attached).

• When piping have to be arranged through above ceiling, closet or where the temperature and humidity are high, wind additional commercially sold insulation to prevent condensation.

4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN

4-1. PURGING PROCEDURES AND LEAK TEST

1) Remove service port cap of stop valve on the side of the outdoor unit gas pipe. (The stop valves are fully closed and covered in caps in initial state.)

2) Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outdoor unit.

*4 to 5 turns

*Open

*Close

Hexagonal wrench

Stop valve cap

(Torque 19.6 to

29.4 N•m, 200 to 300 kgf•cm)

Stop valve for LIQUID

– 0.101 MPa

( – 760 mmHg)

Compound pressure gauge

(for R410A)

Pressure gauge

(for R410A)

Gauge manifold valve

(for R410A)

Handle

Low

Stop valve for

GAS

Handle High

Charge hose

(for R410A)

Service port cap

(Torque 13.7 to

17.7 N•m, 140 to

180 kgf•cm)

Adapter for preventing the back flow Vacuum pump (or the vacuum pump with the function to prevent the back flow)

4-2. TEST RUN

1) Insert power supply plug into the power outlet and/or turn on the breaker.

2) Press the E.O. SW once for COOL, and twice for HEAT operation. Test run will be performed for 30 minutes. If the left lamp of the operation indicator blinks every 0.5 seconds, inspect the indoor/outdoor unit connecting wire (A) for mis-wiring. After the test run, emergency mode (set temperature 24°C) will start.

3) To stop operation, press the E.O. SW several times until all LED lamps turn off. Refer to operating instructions for details.

Emergency operation switch

(E.O. SW)

Checking the remote (infrared) signal reception

Press the ON/OFF button on the remote controller (6) and check that an electronic sound is heard from the indoor unit. Press the ON/OFF button again to turn the air conditioner off.

• Once the compressor stops, the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner.

4-3. AUTO RESTART FUNCTION

This product is equipped with an auto restart function. When the power supply is stopped during operation, such as during blackouts, the function automatically starts operation in the previous setting once the power supply is resumed. (Refer to the operating instructions for details.)

Precautions when using the control valve the service port, valve core may de -

A

Control valve

Open

Close

Body

Service port

Charge hose

When attaching the control valve to the service port, make sure that the valve core is in closed position, and then tighten part A. Do not tighten part A or turn the body when valve core is in open position.

Caution:

• After test run or remote signal reception check, turn off the unit with the E.O. SW or the remote controller before turning off the power supply. Not doing so will cause the unit to start operation automatically when power supply is resumed.

To the user

• After installing the unit, make sure to explain the user about auto restart function.

• If auto restart function is unnecessary, it can be deactivated. Consult the service representative to deactivate the function. Refer to the service manual for details.

3) Run the vacuum pump. (Vacuumize for more than 15 minutes.)

4) Check the vacuum with gauge manifold valve, then close gauge manifold valve, and stop the vacuum pump.

5) Leave as it is for one or two minutes. Make sure pointer gauge manifold valve remains in the same position. Confirm that pressure gauge shows –0.101 MPa [Gauge] (–760 mmHg).

6) Remove gauge manifold valve quickly from service port of stop valve.

7) After refrigerant pipes are connected and evacuated, fully open all stop valves on both sides of gas pipe and liquid pipe. Operating without fully opening lowers the performance and this causes trouble.

8) Refer to 1-3., and charge the prescribed amount of refrigerant if needed. Be sure to charge slowly with liquid refrigerant. Otherwise, composition of the refrigerant in the system may be changed and affect performance of the air conditioner.

9) Tighten cap of service port to obtain the initial status.

10) Leak test

4-4. EXPLANATION TO THE USER

• Using the OPERATING INSTRUCTIONS, explain to the user how to use the air conditioner (how to use the remote controller, how to remove the air filters, how to remove or put the remote controller in the remote controller holder, how to clean, precautions for operation, etc.).

• Recommend the user to read the OPERATING INSTRUCTIONS carefully.

5. RELOCATION AND MAINTENANCE

5-1. REMOVING AND INSTALLING THE PANEL ASSEMBLY 5-3. PUMPING DOWN

When relocating or disposing of the air conditioner, pump down the system following the procedure below so that no refrigerant is released into the atmosphere.

Removal procedure

1) Unlock the upper and lower vanes as shown in and using a thin instrument. Then, remove the horizontal vanes.

2) Remove the 2 screws which fix the panel assembly.

3) Remove the panel assembly. Be sure to remove its bottom right end first.

3

Unlock

Upper and lower vanes

1) Connect the gauge manifold valve to the service port of the stop valve on the gas pipe side of the outdoor unit.

2) Fully close the stop valve on the liquid pipe side of the outdoor unit.

3) Close the stop valve on the gas pipe side of the outdoor unit almost completely so that it can be easily closed fully when the pressure gauge shows 0 MPa [Gauge] (0 kgf/cm 2 ).

4) Start the emergency COOL operation.

To start the emergency operation in COOL mode, disconnect the power supply plug and/or turn off the breaker. After 15 seconds, connect the power supply plug and/or turn on the breaker, and then press the E.O. SW once. (The emergency COOL operation can be performed continuously for up to 30 minutes.)

5) Fully close the stop valve on the gas pipe side of the outdoor unit when the pressure gauge shows 0.05 to 0 MPa [Gauge] (approx. 0.5 to 0 kgf/cm 2 ).

6) Stop the emergency COOL operation.

Press the E.O. SW several times until all LED lamps turn off. Refer to operating instructions for details.

Installation procedure

1) Install the panel assembly following the removal procedure in reverse.

2) Be sure to press the positions as indicated by the arrows in order to attach the assembly completely to the unit.

3) Install the horizontal vanes.

WARNING

When pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes. The compressor may burst if air etc. get into it.

5-2. REMOVING THE INDOOR UNIT

Remove the bottom of the indoor unit from the installation plate.

When releasing the corner part, release both left and right bottom corner part of indoor unit and pull it downward and forward as shown in the figure on the right.

This product is designed and intended for use in the residential, commercial and light-industrial environment.

The product at hand is based on the following

EU regulations:

• Low Voltage Directive 2006/95/EC

• Machinery Directive 2006/42/EC

• Electromagnetic Compatibility Directive 2004/108/EC

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO

100-8310, JAPAN

AUTHORIZED REPRESENTATIVE IN EU:

MITSUBISHI ELECTRIC EUROPE B.V.

HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K.

advertisement

Key Features

  • Installation Manual
  • Split-system air conditioners
  • Detailed installation instructions
  • Safety precautions
  • Purging procedures
  • Leak test
  • Test run
  • Relocation and maintenance
  • Remote controller operation
  • Auto restart function

Frequently Answers and Questions

How do I connect the indoor and outdoor units?
Follow the instructions in the manual for connecting the indoor/outdoor unit connecting wire (A) and the refrigerant pipes. Ensure proper connection and secure tightening of the terminal screws.
What safety precautions should I take during installation?
Read the "THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY" section in this manual carefully. It outlines important safety information and warnings regarding potential hazards during installation.
How do I perform the leak test after installation?
Refer to the Purging Procedures and Leak Test section (4-1) in the manual for step-by-step instructions on performing a thorough leak test using a vacuum pump and gauge manifold valve.
What is the auto restart function and how do I use it?
The auto restart function automatically resumes operation in the previous setting when the power supply is resumed after a power outage. You can find more information about this function in the operating instructions.
What should I do if the air conditioner is not working properly?
Refer to the troubleshooting section in the operating instructions or contact a qualified service representative for assistance.