Home & Business Smart Lock
Before Connecting, operating or adjusting this product, please read the instructions completely.
Keep this manual you will need it again.
is registered trademark of Anviz Global Inc. in the United States and other countries. It cannot be used without the
permission of Anviz.
Before Operation
Note:
Place finger:
1. The lock is equipped with three mechanical keys for manual lock operation. Remove mechanical keys from
the package and keep them in a safe place.
2. To power the lock, four alkaline AA batteries (not included) are required. The lock has low battery voltage
alarm (Red LED flashes and six beeps when you active the lock) to prompt replace battery. Non-alkaline and
Place finger in the center of the sensor.
rechargeable batteries ARE NOT RECOMMENDED.
3. By Default, the lock is configured to grant ANY fingerprint access to unlock.
4. By Default, the lock is configured can not read ID card. Please refer to RFID Card Function to enable card
reading function.
5. Please avoid strong light direct to the lock.
Place finger flat on the sensor surface.
Structure
1
2
3
4
5
6
7
-1-
16
1
LED indicator
2
Fingerprint sensor
3
Card area
4
Mechanical key hole
5
Restart button
6
Rubber key cover
7
9V emergency power terminal
8
Battery box cover
9
Battery area
10
Add key
11
Delete key
12
Nixie tube
13
“OK” Confirm Key
14
“C” Cancel Key
15
Factory Debug Port
16
Mechanical key
8
9
10
13
14
11
12
15
User Operation
User Introduction
Administrator
This will normally be an official in the company or the host of a
family who will have administrator permissions and will be able to
do various operations.
The lock can set 4 administrators and ID will be 96--99.
Normal user
This will be a user under administrator's management who will
be granted access to open the lock. The lock can set 95 normal
users and ID number will be 01--95.
The Nixie tube prompting characters
Character
Description
--
Activation status.
Ad
FP
AL
01-95
96-99
Need administrator identification.
Delete user who is identified by fingerprint or card.
Delete all the users.
ID range for normal users. (95 users capacity)
ID range for administrators.(4 administrators capacity)
The Buzzer status
Status
Buzzer
Description
1
Three Beeps
The lock under initial states and be activated.
2
Two Beeps
Enable or Diable work mode.
3
Long Voice
Finger or Card Verification failed.
4
Short music voice
Operation succeedful.
5
Six beeps
Delete all the user / low battery voltage alarm.
RFID Card Function
RFID Card Function: Enable this function the lock can read ID cards.
The battery lifespan can be doubled after disabling the RFID Card
Function.
Enable: Verify any registered fingerprint on lock and press
key.
Disable: Verify any registered fingerprint on lock and press
key.
Normal Open Function
Normal open function: Open the door without fingerprint or card
verification on the lock, which is fit for meeting room and some
places free to in or out.
Enable: Verify any registered fingerprints or cards on lock and
press OK key.
Disable: Press C key directly.
Initialize The Fingerprint Lock
Initializing the fingerprint lock means all of the user will be deleted
and back to factory mode.
Operation:
The Initialization Button is in the inside panel of the lock, and holding the
Initialization Button until the lock prompts the voice of initialization.
When initialization is completed, the fingerprint lock will restart automaticly.
Note: Fingerprint Lock Initialization must be supplied with power.
Initialization Button
The LED status
LED
Status
Description
1
Bule LED flashes
Activation status.
2
Bule LED fast flashing
Place same finger or swipe same card again.
3
Red LED flashes
Delete user status / low battery voltage alarm.
4
Red LED fast flashing
Place same finger or swipe same card again to delete.
5
Bule and Red LED flashes
Need administrator verify.
6
Red LED light
Unregistered finger or card .
-2-
Quick Operation Mode
Register User (Register user without administrator.)
1
2
Remove the battery box cover.
Press any key to activate the
lock.
The Nixie tube shows “--”.
3
Pressing
6
5
key.
The Nixie tube will display
normal user ID: 01. Please
press
and
key to select
and press OK to enter the
registration status.
(User ID range is 01-95)
* Note:
One ID only can register one fingerprint or one card.
Next ID number will be
displayed after successful
registration.
Press OK to continue register
user or press C key to exit
register status.
Place one user finger twice
on the fingerprint sensor or
swipe card on the card area
twice.
4
-3-
Delete User (Delete user without administrator.)
1
2
Remove the battery box cover.
Press any key to activate the
lock.
The Nixie tube shows “--”.
5
If "FP" selected, Press OK key need to place finger twice on the sensor
or swipe card twice to delete. Press OK key to continue delete other
users or press C key to exit delete status.
If "AL" selected, Press OK key after six beeps form the lock all of the
normal users will be delete. The lock will auto logout deletion status.
If "ID" selected, press OK to delete the appointed user. Press C key to
exit delete status or press
and
key to continue select ID number
delete the appointed user.
-4-
3
Pressing
4
key.
When the Nixie tube flashes,
please press
and
key to
select “FP”, “AL” or “ID”
number and press OK .
Normal Operation Mode
Register First Administrator (The first time uses lock to register administrator.)
1
2
Remove the battery box cover.
Press any key to activate the
lock.
3
The Nixie tube shows “--”.
5
When it shows admin ID:
96, press
or
to select
ID then OK to confirm.
(range : 96-99)
key for 3 sec.
Hold
6
* Note:
One ID only can register one fingerprint or one card.
Next ID number will be
displayed after successful
registration.
Press OK to continue
register user or press C key
to exit register status.
Place one Admin finger twice
on the fingerprint sensor or
swipe card on the card area
twice.
4
-5-
Register other Administrators
1
2
Remove the battery box cover.
Press any key to activate the
lock.
The Nixie tube shows “--”.
5
3
key for 3 sec.
Hold
6
Please verify Admin FP or
swipe Admin card to enter
the registration status.
It shows “ID” number, press
or
key to select ID then
press OK to confirm.
4
Then it shows “Ad“.
7
8
Place one user finger twice on
the fingerprint sensor or swipe
card on the card area twice
(Please enable card function).
Next ID number will be
displayed after successful
registration.
Press OK to continue register
user or Press C key to exit
registration status.
-6-
Register Normal User
1
2
Remove the battery box cover.
Press any key to activate the
lock.
3
The Nixie tube shows “--”.
5
Pressing
6
The Nixie tube will display
normal user ID: 01. Please
press
and
key to select
and press OK to enter the
registration status.
(User ID range is 01-95)
Please verify Admin FP or
swipe Admin card to enter
the registration status.
4
Then it shows “Ad’’.
key.
7
8
Place one user finger twice on
the fingerprint sensor or swipe
card on the card area twice.
Next ID number will be
displayed after successful
registration.
Press OK to continue register
user or press C key to exit
exit register status.
-7-
Delete User
1
2
Remove the battery box cover.
Press any key to activate the
lock.
The Nixie tube shows “--”.
5
Please verify Admin FP or
swipe Admin card to enter
the registration status.
3
Pressing
4
key.
6
When the Nixie tube flashes,
please press
and
key to
select “FP”, “AL” or “ID”
number and press OK .
Then it shows “Ad’’.
7
If "FP" selected, Press OK key need to place finger twice on the sensor
or swipe card twice to delete. Press OK key to continue delete other
users or press C key to exit delete status.
If "AL" selected, Press OK key after six beeps form the lock all of the
normal users will be delete. The lock will auto logout deletion status.
If "ID" selected, press OK to delete the appointed user. Press C key to
exit delete status or press
and
key to continue select ID number
delete the appointed user.
-8-
Delete Administrators
1
Remove the battery box cover.
Press any key to activate the
lock.
5
Please verify Admin FP or
swipe Admin card to enter
the registration status.
2
The Nixie tube shows “--”.
6
When the Nixie tube flashes
please. press
and
key to
select “FP”. “AL” or “ID”
number. Then press OK .
3
Hold
4
key for 3 sec.
Then it shows “Ad’’.
7
If "FP" selected, Press OK key need to place administrator finger twice
on the sensor or swipe card twice to delete. Press OK key to continue
delete other administrator or press C key to exit delete status.
If "AL" selected, Press OK key after six beeps form the lock all of the
administrators will be delete. The lock will auto logout deletion status.
If "ID" selected, press OK to delete the appointed administrator. Press
key to exit delete status or press
and
key to continue select ID
number delete the appointed administrator.
-9-
C
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement