Fluke Calibration Products and Services

Fluke Calibration Products and Services
Fluke Calibration
Products and Services
Short Form Catalog
Precision, performance, confidence.™
Electrical
Temperature
RF
Pressure
Flow
Software
Dear Customer,
In our 2011 product catalog, we asked the question, “What’s next for Fluke
Calibration?” and we went on to answer our own question like this:
“Relentless continuous improvement. Our goal is to bring
you more new products, better service and support, better
operations impacting product quality and delivery times—and
to do all of this all around the world and not just in the U.S.
We want to be your preferred source for the best calibration
instruments and we don’t want it to even be close.”
Three things are certain regarding those comments. We have made progress.
We’re not claiming victory. And high-quality products, high-quality service, and
reliable operations remain high priorities for us.
Since that catalog came out in 2011, we have…
• Introduced a new product roughly every two months and updated and upgraded
dozens of other products—including showing our continuing commitment to our
popular MET/CAL software platform.
• Introduced new services and service support plans around the world.
• Improved on-time product delivery from our factories from about 75 % to
consistently better than 90 %.
• Expanded service capabilities in a number of service centers around the world.
• Improved on-time service delivery in many parts of the world: going from about
45 % on-time delivery (after acquisition-related reorganization) to consistently
better than 93 % in our U.S. service centers, making similarly dramatic improvements in China, and moderately accelerating in other geographies.
It’s not enough, but it’s a start—or, better said, it’s a continuation of a course we set
out on when the Fluke Calibration brand was born in 2010. Are we today “your
preferred source for the best calibration instruments” (and software and services)?
We hope so. But whether we are or are not, we understand that we won’t be in
the future unless we continue to get better and deliver more of the things you
need all around the world.
We hope this catalog provides a helpful reference to you for the many products
Fluke Calibration offers across electrical, temperature, pressure, flow and calibration software. We are committed to excellent metrology. We are committed to
building upon the legacies of the brands we have acquired. We are committed to
listening to you and your needs and responding as urgently as we can.
To that end, if you ever have an idea or concern that you’d like to take straight
to the leadership team of Fluke Calibration, don’t hesitate to contact us at
flukecal-leadership@flukecal.com. We can’t promise that we’ll give you whatever
you want as soon as you want it, but we will promise to listen and be as responsive as we can.
Enjoy the catalog and let us know directly—or through any of our sales
representatives—how we can best serve you today.
Sincerely,
The Fluke Calibration Team
www.flukecal.com
Table of contents
2
Electrical
calibration
DC/LF Electrical Calibrators..........................................5
Specialty Calibrators......................................................6
Oscilloscope Calibrators.................................................7
Precision Multimeters ....................................................7
Electrical Standards.......................................................8
9
RF
calibration
26
Pressure
calibration
Gas Pressure Controllers/Calibrators........................ 30
High Pressure Controllers/Calibrators...................... 31
Reference Pressure Indicators................................... 31
PG7000 Series Piston Gauges.................................... 32
2400 Series Piston Gauges........................................ 32
Specialty Piston Gauges.............................................. 33
Manual Pressure Generation and Control................ 33
Industrial Deadweight Testers................................... 34
Pressure Comparators................................................. 34
Pressure Calibrators.................................................... 35
Air Data Calibration..................................................... 36
Pressure Calibration Systems.................................... 36
RF References............................................................... 10
11
Temperature
calibration
Standard Platinum Resistance Thermometers........ 18
ITS-90 Fixed-Point Cells............................................ 18
Cell Maintenance Apparatus...................................... 19
Thermometer Readouts............................................... 20
Temperature Probes ....................................................21
Temperature Calibration Baths.................................. 22
Dry-Well Calibrators.................................................... 23
Infrared Calibrators..................................................... 25
Thermocouple Furnaces.............................................. 25
Miscellaneous Dry-Well Calibrators......................... 25
37
Gas flow
calibration
Gas Flow Standards..................................................... 38
Primary Gas Flow Standard....................................... 38
39
Calibration
software
Electrical and RF Calibration Software.....................41
Calibration Asset Management Software.................41
Software Support Programs........................................41
Temperature Calibration Software........................... 42
Pressure/Flow Calibration Software......................... 43
44
Data acquisition
and general purpose test
Service programs.........................................48
Training...........................................................49
www.flukecal.com
Electrical calibration
Electrical calibration refers to the process of
verifying the performance of, or adjusting, any
instrument that measures, sources, or tests
electrical parameters. This discipline is usually
referred to as dc and low frequency ac electrical
metrology. Principal parameters include voltage,
current, resistance, inductance, capacitance,
time and frequency. Other parameters, including
electrical power and phase, are also in this
segment of metrology. Ratiometric comparisons of
similar parameters are often performed to compare
a known parameter to an unknown similar
parameter.
Electrical calibration involves the use of precise
devices that evaluate the performance of key
properties for other devices called units under
2
Electrical Calibration
test (UUTs). Because these precise devices have
thoroughly known performance characteristics
compared to the UUT, performance evaluation
and/or calibration adjustment of the UUT to
identify or minimize errors is possible. Typically,
the performance of such precision devices should
be four or more times better than the UUT.
These precision devices fall into two broad
categories. Electrical signal sources are often
referred to as either calibrators or standards.
Precision measurement devices are often classified
as reference digital multimeters, measurement
standards, or ratio bridges.
www.flukecal.com
Product highlights
5730A Multifunction Calibrator
6135A/PMUCAL PMU Calibrator
The new gold standard in electrical calibration
Fast, automated, traceable calibrations that
comply with IEEE C37 118.1™-2011
The Fluke Calibration 5730A High Performance
Multifunction Calibrator is the culmination of years
of engineering development, customer research
and industrial design, to bring to market the new
“gold standard” in multifunction calibration. Like
its predecessors, the 5700A and 5720A calibrators,
the 5730A calibrates a wide range of digital multimeters, up to long-scale 8.5 digit DMMs, as well
as a wide-range RF multimeters. This new model
features improved specifications that will help you
increase test uncertainty ratios (TURs) and improve
test confidence.
• 6.5 inch VGA capacitive touchscreen with full
color graphical user interface
• Menus and functions displayed in choice of nine
languages
• Visual Connection Management ™ terminals guide
cable connections
• Extended operational reliability through the use
of modern analog and digital components and
state-of-the-art circuit board technologies
• Artifact Calibration—the process of using just
three external standards—10 V, 1 ohm and
10 k ohm, to automatically adjust the entire
instrument—optimizes performance to the best
specified performance.
• Cal Check—a process that tests all function
and ranges for any drift since the most recent
calibration—provides ongoing confidence in
performance. Any output drift is measured and
evaluated it with respect to specification.
• Compatible with 52120A and 5725A amplifiers
• Full MET/CAL® compatibility with 5700A
and 5720A procedures (MET/CAL versions 7.3
and above)
www.flukecal.com
The 6135A/PMUCal Phasor Measurement Unit Calibration System is the only automated and traceable
PMU calibration system available today. It is an
ideal solution for PMU designers and manufacturers, as well national metrology institutes (NMIs).
It’s also a perfect solution for third party calibration
houses and electrical utilities.
Applications include calibrating PMUs before
they are installed, and as required throughout their
operational life; performing type tests of PMUs
and other power grid tools; and performing first
article approvals. And because the 6135A includes
a three-phase 6135A Electrical Power Calibration
Standard, you can also use it to cover a wide workload of electrical power test instruments.
The 6135A/PMUCAL system enables you to:
• Calibrate and test a PMU from a PC, either at
the site of the test system or remotely over the
internet
• Quickly set up a PMU test
• Speed through automated calibration procedures
quantifying the time savings would be a nice
addition
• Simulate static and dynamic voltage and current
conditions that occur in a power distribution grid
• Apply those signals to a phasor measurement
unit
• Capture the PMU’s reported results
• Compare those results with the original stimulus
• Evaluate against the thresholds defined in IEEE
C37.118.1™-2011
• Create test reports, graphs and calibration certificates that can be readily printed or shared
electronically
Electrical Calibration
3
Selection guide
Multi-Product
Calibrators
Workload
5080A
5502A
Multifunction
Calibrators
5522A
5700A
5730A
Oscilloscope
Calibrators
Electrical
Tester
Calibrator
9500B
5320A
Power
Standards
6100B
6105A
Precision Process
Calibrators
525B
7526A
V dc, I dc & R
V dc, I dc & R
Analog/panel meters
High burden meters
Low burden meters
V dc & V ac
DMMs
Basic dc V accuracy
100 ppm
50 ppm
11 ppm
6.4 ppm
3.5 ppm
n/a
3.5 digits
0.10 %
112 ppm
42 ppm
V dc & V ac
(typ. ± 0.3 % dc V)
40 ppm
40 ppm
V dc, I dc & R
V dc & V ac
opt
opt
9
9
4.5 digits
(typ. ± 0.025 % dc V)
5.5 digits
(typ. ± 0.015 % dc V)
6.5 digits
(typ. ± 0.0024 % dc V)
7.5 digits
(typ. ± 12 ppm dc V)
8.5 digits
(typ. ± 3.9 ppm dc V)
Temperature/pressure
RTD simulate
RTD measure
Thermocouple
simulate
Thermocouple
measure
Pressure modules
opt
Two-wire
transmitters
Oscilloscopes
200 MHz to 600
MHz
1 to 5 channels
200 MHz
opt
300 MHz or
600 MHz
opt
1.1 GHz
600 MHz
opt
600 MHz std
1 GHz opt
9510 Head opt
3.2 GHz
9530 Head opt
6.4 GHz
9560 Head opt
25 ps fast edge
(14 GHz)
9550 Head opt
Safety testers
Hipot
Megohm meters
MEG opt
Installation
PATs
Continuity
MEG opt
Loop impedance
Leakage current
Ground bond
RCD/GFCI
Medical safety
Power/energy
Wattmeters
Harmonic analyzers
Flicker meters
PQ opt
Phase angle meters
PQ opt
Power analyzers
PQ opt
Power recorders
Secondary energy
standards
Watthour/
energy meters
Other
Clamp meters
5500A/
COIL
LCR meters
5500A/
COIL
5500A/
COIL
RC only
RC only
11
11
52120A Amp
+ COIL opt
52120A Amp
+ COIL opt
30 MHz WB opt
30 MHz WB opt
5
5
Process calibrators
Data acquisition
Non sine waveforms
RF millivolt meters
# of calibrator
functions
8
11+
9
8
8
5730A
5502A
5700A
5522A
5080A
DC/LF Electrical
Calibrators
5730A Multifunction
Calibrator
The new gold standard in
electrical calibration.
• The next generation highperformance multifunction
calibrator
• Support instruments of up to
8.5 digits in measurement
performance
•Artifact Calibration permits
the lowest cost of support
and highest confidence in
performance
• New internal printed circuit
boards with upgraded digital
technology
• 6.5 inch VGA capacitive
touchscreen with full color
graphical user interface
• Menus and functions displayed in choice of nine
languages
• Optional wideband output to
30 MHz
5502A Multi-Product
Calibrator
5700A Multifunction
Calibrators
Robust, transportable solution to
match your workload and budget.
• Calibrates a wide variety of
electrical test equipment
• Robust protection circuits
prevent costly damage from
operator error
• Ergonomically designed
carrying handles
• Rugged optional case with
built-in handles and wheels
and removable front/rear
access doors
• Optional oscilloscope
calibration to 600 MHz
A proven, high-accuracy
calibrator.
• It will support instruments
of up to 7.5 to 8.5 digits in
measurement performance
• Artifact Calibration permits
the lowest cost of support
and highest confidence in
performance
• Optional wideband output to
30 MHz
5522A Multi-Product
Calibrator
Robust, transportable wide workload coverage.
• Calibrates a wide variety
of electrical test equipment
with more than 14 functional
capabilities
• Accuracies intended to support
DMMs to 6.5 digits
• Robust protection circuits
prevent costly damage from
operator error
• Optional oscilloscope calibration to 1100 MHz
• Easy to transport
www.flukecal.com
5080A High Compliance
Multi-Product Calibrator
Solutions for your analog and
digital workload.
• High compliance for difficultto-calibrate analog instruments
• Robust protection circuits
prevent costly damage from
operator error
• Calibrates a wide workload,
including analog meters and
3.5 and 4.5 digit DMMs
• Options for oscilloscope and
megohm meter calibration
Electrical Calibration
5
6105A/6100B
52120A
7526A
5725A
6135A/PMU
6135A/PMU Phasor
Measurement Unit Calibrator
5320A
Specialty
Calibrators
525B
52120A Transconductance
Amplifier
Test and calibrate power standards, power and energy meters,
6105A/6100B Electrical
PQ analyzers, high-current clamp
Power Standards
meters and Rogowski coils.
Delivers:
The most accurate, compre• 120 A standalone
hensive and flexible sources
• 240 A or 360 A with parallel
of electrical power quality and
operation
energy signals.
• 3000 A or 6000 A with acces• Power calibration with voltsory coils
age to 1008 V and current to
•
Industry-leading amplifier
21 amps, and optionally up to
accuracy:
80 amps
– 100 PPM dc to 850 Hz
• Voltage and current accuracies
– 120 PPM dc and 260 PPM ac
better than 0.005 % (50 ppm)
in stand-alone operation
• Current to voltage phase
• Frequency capability, dc to
accuracy of 0.003 °
10 kHz
• Programmable harmonic distortion up to 100 harmonics
• Includes other power quality
7526A Precision Process
testing phenomena
Calibrator
• Complex measurements generBest balance of economy and
ating a wide variety of signals
accuracy for calibration of temperature and pressure process
5725A Amplifier
measurement instrumentation.
• Sources and measures dc voltThe Fluke 5725A Amplifier is a
age, current, resistance,
companion to the 57XX Series
• Measures and simulates RTDs
calibrators.
and thermocouples
• Extends the calibrators’ alter• Measures pressure using Fluke
nating volt-hertz product to
700/525A-P pressure modules
1100 V at 30 kHz and 750 V at
• Includes 24 V dc loop power
100 kHz
supply, automated switch-test
• Increases maximum direct and
function and measures 4 mA to
alternating current to 11 A
20 mA
6
Electrical Calibration
Fast, automated, IEEE C37
118.1-2011-compliant PMU
calibrations. System includes:
• PMU control unit
• GPS receiver
• PMU test and calibration
software
• Fluke 6135 Electrical Power
Standard
• Configured server PC
5320A Multifunction
Electrical Tester Calibrator
Verify and calibrate electrical test
tools with a single instrument.
• Calibrate megohm meters, earth
resistance testers, ground bond
testers, hipots, installation
testers and many more types of
electrical safety testers
• Uses less bench space than
custom solutions
• Built-in graphical calibration
help guide
• LAN, GPIB, RS-232 interfaces
for PC based automation
525B Temperature/Pressure
Calibrator
Superior accuracy and functionality in an economical benchtop
package.
• A calibrator to address process
industry instrumentation
• Simulates and measures all
ANSI thermocouples, as well
as L and U types, and provides
cold junction compensation
to enable calibration of a
wide variety of thermocouple
instrumentation
• Direct input for storage of
ITS-90 RTD constants
• RTD source uncertainties to
0.03 °C
www.flukecal.com
9500B
55XX
8508A
8845A/8846A
8808A
Oscilloscope
Calibrators
9500B Oscilloscope
Calibrator
The highest performance, fully
automated, upgradeable oscilloscope calibration workstation.
• Full automation provides totally
hands-free calibration
• Bandwidths of 600 MHz,
1000 MHz, 3200 MHz, and
6400 MHz
• A fast edge of 25 ps to address
bandwidths up to 14 GHz
• Connect up to five channels
simultaneously
55XX Series Oscilloscope
Calibration Options
Options for the 5502A and 5522A
calibrators add capabilities to
calibrate your digital and analog
oscilloscopes with any of three
different ranges of bandwidths.
• Leveled sine wave generator
with optional bandwidths
of 300 MHz, 600 MHz and
1100 MHz for verifying
oscilloscope bandwidth
• DC and square wave voltage
generators for calibrating voltage gain
• Horizontal time base calibration functions
• Edge source including a 300 ps
fast edge with low aberrations
for verifying dynamic response
• Fast edge risetime pulse
generator (< 1 ns) for checking
pulse response
www.flukecal.com
Precision Multimeters
8508A Reference Multimeter 8845A/8846A Precision
Multimeters
Reference standard accuracy
and stability, in one functionally
versatile, easy-to-use solution.
• 8.5 digit resolution, exceptional
linearity and low noise and
stability
• Optional electronic front/
rear inputs with unique ratio
measurement option
• Broad range of measurement
capabilities
• 365 day stability as low as
2.7 ppm, 24-hour stability of
0.5 ppm, transfer uncertainty
of 0.12 ppm
Precision and versatility for bench
or systems applications.
• 6.5 digit resolution
• Basic V dc accuracy of up to
0.0024 %
• Dual display, showing two
different measurements at once
8808A Digital Multimeter
Versatile multimeter for manufacturing, development and service
applications.
• 5.5 digit resolution
• Basic V dc accuracy of 0.015 %
• Dual display, showing two
different measurements at once
Electrical Calibration
7
732B/734A
A40B
792A
A40/A40A
5790A
742A
752A
720A
910/910R
908/909
Electrical
Standards
732B/734A DC Reference
and Transfer Standards
The simple way to maintain and
disseminate your volt.
• A primary standard for traceability of dc voltage to better
than 1 ppm
• Complete mechanical and electrical independence of each of
its four standards (734A)
• Battery powered for easy
shipping
792A AC/DC Transfer
Standard
Support for your most demanding
ac traceability requirements.
• A primary standard that is
accurate, fast and easy to use
• Fully traceable performance
with ac/dc difference to better
than 10 ppm
• Nine ranges from 22 mV to
1000 V (with external range
resistor)
5790A AC Measurement
Standard
Automated ac measurement with
precision that is easy to use.
• Direct ac measurements to
22 ppm, or ac/dc difference
measurements to 15 ppm
• Digital voltmeter style operation that features a fully
autoranging instrument that
selects the best voltage range
for the measurement you are
making
• Robust 1200 V input protection
on all voltage ranges
• Optional 30 MHz wideband
measurement
8
Electrical Calibration
742A Resistance Standard
720A Kelvin-Varley Divider
High accuracy working standard
for on-site resistance calibration.
• Small and rugged standard
resistors with six-month stabilities to 2.5 ppm
• Open air use so no oil or air
baths required
• 18 °C to 28 °C operating range
• Standard values from 1 ohm to
100 Megohms
A primary standard for ratio
measurements.
• 0.1 ppm resolution, seven
decades
• 0.1 ppm of input absolute
linearity
• Built-in self-calibration bridge
A40B Series Precision
Current Shunts
Cesium controlled frequency
standard that uses GPS technology and connectivity to provide
primary standard traceability
from any location.
• Unique traceability feature
means no more re-calibrations
• Two high-stability models to
meet your application and fit
your budget
• Built-in rubidium atomic clock
(910R)
• Up to 13 outputs, maximizing
cost efficiency
Precision, low inductance shunts
for dc and ac current metrology.
• Simplifies calibration/verification of precision calibrators
and current sources
• Shunts sized for current from
1 mA to 100 A
• Usable from dc to 100 kHz
• Ultra low phase shift to support power quality instrument
metrology
A40/A40A Current Shunts
• AC current transfer measurements from 2.5 mA to 20 A
• Frequency between 5 Hz to
100 kHz
752A Reference Divider
Setting the standard for ratio
accuracy and ease of use.
• Key standard for calibrating
57xx Series Calibrators
• 10:1 and 100:1 divider outputs
• Output uncertainty 0.2 ppm
and 0.5 ppm
• Built-in calibration bridge
910/910R GPS Controlled
Frequency Standard
908/909 Frequency
References
Stable frequency references for
test systems and calibration labs.
• Accurate reference “atomic
clock” in automated test
systems
• Affordable and very cost
effective
• Designed for portability with
optional carrying case
www.flukecal.com
RF calibration
RF and microwave calibration refers to the process
of verifying the performance of, or adjusting/
deriving corrections for, any instrument or
component that will be used in the measurement
or testing of RF and microwave parameters.
This discipline is usually referred to as RF and
microwave metrology. Principal parameters include
RF voltage, RF power, impedance, modulation,
distortion, time, frequency and phase. High
dynamic range ratiometric comparisons are
often performed and results are expressed in the
logarithmic “dB” form.
As with any other calibration, RF and microwave
calibration compares a device or unit under test
(DUT or UUT) to a traceably calibrated standard or
reference device. The process typically involves
comparing a measuring UUT to a reference source;
a sourcing UUT with a measuring reference; or
quite commonly a measuring UUT with a measuring
reference, using a stable but unknown source.
In each case, the uncertainty or stability of the
reference should significantly exceed the specified
performance of the device or unit under test.
RF metrologists typically look for performance
margins of 4:1, however, test uncertainty ratios
lower than this usual target are more frequently
encountered in RF than in other calibration
disciplines. Conversion from logarithmic (dB)
to linear units is recommended practice when
combining uncertainty contributions and
considering test uncertainty ratios.
www.flukecal.com
Precision devices that are commonly used in RF
and microwave calibration fall broadly into four
categories:
Sourcing instruments. Reference signals and/
or modulation sources, frequency references,
pulse or arbitrary waveform generators, reference
attenuators.
Measuring instruments. Power sensors, spectrum
analyzers, measuring receivers, oscilloscopes, RF
voltmeters, frequency counters.
Source-measure instruments. Vector or scalar
network analyzers.
Precision components
• Power splitters, power dividers or couplers,
attenuating pads
• Inter-series, polarity or sacrificial cables and
adapters
• Short, open, load or sliding terminators
• Reflection bridges or directional couplers
RF Calibration
9
9640A
9640A-LPNX
RF References
10
9640A RF Reference
9640A-LPNX RF Reference
A unique blend of accuracy, stability, resolution, purity, dynamic
range and low noise.
The Fluke 9640A is an RF
reference source, reference attenuator, reference local oscillator
and frequency counter and is the
key component in a simplified,
streamlined RF and microwave
calibration system.
• Takes the central role and
typically halves the cost of a
higher capability RF calibration
system and delivers certified
accuracy directly to the UUT
via a single signal connection
• Via MET/CAL software and an
extensive procedure library,
realizes “walk away” automation and a new level of
efficiency for spectrum analyzer calibration
• A highly integrated and robust
solution for
on-site RF calibration and a
GPIB emulating
drop-in replacement for the
legacy HP3335 RF source and
attenuator
• Performs 80 to 100 percent
of tests required on high
performance high frequency
spectrum analyzers
• Also calibrates power sensor
linearity, millivoltmeters,
signal level meters, modulation analyzers, receivers and
counter/timers
With higher performance, stateof-the-art phase noise or timing
jitter, the LPNX version of the
9640A RF Reference addresses
the most demanding RF calibration and local oscillator
applications.
• -138 dBc/Hz at 1 GHz and
5 kHz to 100 kHz offset
• Optional drop-in GPIB emulation of the legacy HP8662/3
RF sources
• Optional 9600FLT 1GHz phase
noise filter for high margin
calibrations at > 5 MHz offset
RF Calibration
www.flukecal.com
www.flukecal.com
Temperature calibration
Temperature calibration refers to the calibration
of any device used in a system that measures
temperature. Most importantly, this usually means
the temperature sensor, itself, which is typically a
platinum resistance thermometer (PRT or PT-100),
thermistor, or thermocouple. Readings from these
thermometers are made by “thermometer readout”
devices which measure their electrical outputs
and convert them to temperature according to the
International Temperature Scale of 1990 (ITS-90).
Thermometers are typically calibrated by placing
them in a stable temperature environment (heat
source) and comparing their output to that of a
calibrated “reference thermometer” or “standard
thermometer.” Fluke Calibration provides three
www.flukecal.com
general categories of heat sources: industrial heat
sources (dry-well calibrators, Micro-Baths, etc.) for
field use; fluid baths and thermocouple furnaces for
laboratory use; and fixed-point cells for “primary”
calibrations. Fluke Calibration also offers a variety
of reference thermometers, including SPRTs, and
thermometer readout instruments.
In addition, Fluke Calibration provides laboratory
and field solutions for calibrating the electronics
used in temperature measurement circuits.
Temperature Calibration
11
Product highlights
9190A Ultra-Cool Field Metrology Well
Ultra-cool dry-block calibrator with best-inclass stability
The 9190A Ultra-Cool Field Metrology Well is
the most accurate and stable, cold temperature
dry-block on the market. It’s ideal for applications
that demand strict quality control and regulatory
process compliance. These applications include
on-location validation and calibration of RTDs,
thermocouples, thermometers, and sensors used
with process control equipment such as medical
freezers, laboratory refrigerators, cold rooms, blood
banks, sterilizers (autoclaves), and freeze dryers.
• Wide temperature range from –95 °C to 140 °C
• Best-in-class stability: ± 0.015 °C full range
• Accuracy using built-in reference thermometer
readout: ± 0.05 °C full range
• Display accuracy: ± 0.2 °C full range
12
Temperature Calibration
1586A Super-DAQ Precision
Temperature Scanner
The most accurate, flexible temperature data
acquisition system
The 1586A is ideal for benchtop calibration of
temperature sensors in secondary calibration
labs, as well as temperature data acquisition
applications in industries such as pharmaceutical,
bio-technology, aerospace, food and energy where
accurate temperature measurements are critical.
• Measure thermocouples, PRTs, thermistors, dc V,
dc I, and resistance
• Best-in-class temperature measurement
accuracy:
– PRTs: ± 0.005 °C (using external DAQ-STAQ
Multiplexer)
– T hermocouples: ± 0.5 °C (using High-Capacity
Module and internal CJC)
– Thermistors: ± 0.002 °C
• Connect up to 40 isolated inputs
• Scan speed of up to 10 channels per second
• Four modes of operation: Scan, Monitor,
Measure, DMM
• Real-time color trending—chart up to four
channels simultaneously
• Controls Fluke Calibration temperature sources
such as dry-wells or micro-baths for automated
calibration routines
• MX + B scaling and channel offset zero function
• Built-in data security levels
www.flukecal.com
Selection guides
Primary standards
Standard platinum resistance thermometers (SPRTs)
Model
RTPW
Description
5681
25.5 Ω
–200 °C to 670 °C, quartz sheath
5683
25.5 Ω
–200 °C to 480 °C, quartz sheath
5684
0.25 Ω
0 °C to 1070 °C, quartz sheath
5685
2.5 Ω
0 °C to 1070 °C, quartz sheath
5698
25.5 Ω
–200 °C to 670 °C, working standard, quartz sheath
5699
25.5 Ω
–200 °C to 670 °C, high temperature, metal sheath
5686
25.5 Ω
–260 °C to 232 °C, glass capsule
ITS-90 Fixed-point cells
Model
Description
Temperature
Triple point of water cells
Features/use
Maintenance apparatus
5901A-G
TPW Cell, 12 mm ID with handle, glass shell
0.01 °C
5901A-Q
TPW Cell, 12 mm ID with handle, quartz shell
0.01 °C
5901C-G
TPW Cell, 13.6 mm ID with handle, glass shell
0.01 °C
5901C-Q
TPW Cell, 13.6 mm ID with handle, quartz shell
0.01 °C
5901D-G
TPW Cell, 12 mm ID, glass shell
0.01 °C
5901D-Q
TPW Cell, 12 mm ID, quartz shell
0.01 °C
5901B-G
TPW Cell, mini, glass shell
0.01 °C
Standard size fixed-point cells
5900E
TP Mercury, SST
–38.8344 °C
5904
Freezing Point of Indium
156.5985 °C
5905
Freezing Point of Tin
231.928 °C
5906
Freezing Point of Zinc
419.527 °C
5907
Freezing Point of Aluminum
660.323 °C
5908
Freezing Point of Silver
961.78 °C
5909
Freezing Point of Copper
1084.62 °C
5924
Open Freezing Point of Indium
156.5985 °C
5925
Open Freezing Point of Tin
231.928 °C
5926
Open Freezing Point of Zinc
419.527 °C
5927A
Open Freezing Point of Aluminum
660.323 °C
5928
Open Freezing Point of Silver
961.78 °C
5929
Open Freezing Point of Copper
1084.62 °C
5943
Melting Point of Gallium, SST
29.7646 °C
7012
Maintains: triple point of water and gallium cells.
Comparisons: –10 °C to 110 °C.
7037
Maintains: triple point of water and gallium cells.
Comparisons: –40 °C to 110 °C.
7312
Maintains: two TPW cells. Compact size, runs quietly.
Comparisons: –5 °C to 110 °C.
7341
Maintains: triple point of mercury cell.
Comparisons: –45 °C to 150 °C.
9210
Maintains: mini triple point of water.
Comparisons: –10 °C to 125 °C.
9230
Maintains: stainless steel gallium cell. Comparisons: 15 °C
to 35 °C.
9260
Maintains: indium, tin, zinc, and aluminum cells.
Comparisons: 50 °C to 680 °C.
9114
Maintains: indium, tin, zinc, and aluminum cells.
Comparisons: 100 °C to 680 °C.
9115A
Maintains: aluminum and silver cells.
Comparisons: 550 °C to 1000 °C.
9116A
Maintains: aluminum, silver, gold, and copper cells.
Comparisons: 400 °C to 1100 °C.
9117
Anneals SPRTs, HTPRTs, and thermocouples to 1100 °C.
Protects them against contamination from metal ions.
Boiling point of liquid nitrogen
7196
5901B
Mini Triple Point of Water
0.01 °C
5914A
Mini Freezing Point of Indium
156.5985 °C
5915A
Mini Freezing Point of Tin
231.928 °C
5916A
Mini Freezing Point of Zinc
419.527 °C
5917A
Mini Freezing Point of Aluminum
660.323 °C
5918A
Mini Freezing Point of Silver
961.78 °C
5919A
Mini Freezing Point of Copper
1084.62 °C
5944
Mini Freezing Point of Indium, Metal Cased
156.5985 °C
5945
Mini Freezing Point of Tin, Metal Cased
231.928 °C
5946
Mini Freezing Point of Zinc, Metal Cased
419.527 °C
5947
Mini Freezing Point of Aluminum, Metal Cased
660.323 °C
Affordable substitute for a triple point of argon system.
Provides for low-temperature comparison calibrations at
approximately –196 °C with uncertainties of 2 mK.
Triple point of argon system
5960A
Mini triple point of water and fixed-point cells
www.flukecal.com
Model
Lowest uncertainty for any commercially available triple
point of argon system.
Standard resistors
742A
Excellent performance without oil or air baths.
Values from 1 ohm to 19 megohm.
5430
Highest stability oil-filled resistors (< 2 ppm/year drift).
AC cal uncertainty to 3 ppm.
Temperature Calibration
13
Thermometer readouts
Intrinsically safe thermometers
1551A Ex
100 Ω thin-film RTD
–50 °C to 160 °C
(–58 °F to 320 °F)
1552A Ex
100 Ω wire-wound PRT
–80 °C to 300 °C
(–112 °F to 572 °F)
Accuracy of ± 0.05 °C (± 0.09 °F) over full range.
Intrinsically safe (ATEX and IECEx compliant).
Two models to choose from (-50 °C to 160 °C or -80 °C to 300 °C)
Precision digital thermometer readouts
Model
Probe types
Accuracy at 0 °C
Features
1502A
PRTs
± 0.006 °C
Resolution of 0.001 °C and accuracy to match; uses ITS-90, IPTS-68, CVD,
or DIN (IEC 751) conversions
1504
Thermistors
± 0.002 °C
Reads thermistors from 0 to 500 KW; uses Steinhart-Hart and CVD
1523
PRTs, Thermistors,
Thermocoouples
± 0.002 °C
Battery-powered, handheld reference thermometer; INFO-CON connector
reads coefficients without programming; saves 25 readings on demand;
graphs trends
1524
PRTs, Thermistors,
Thermocoouples
± 0.002 °C
Handheld reference thermometer same as 1523 but with inputs for two
thermometers; logs up to 15,000 readings and stores 25 more on demand
PRTs, Thermistors,
Thermocouples
± 0.006 °C (PRT)
Four channels can all be measured simultaneously; battery-powered; logs
up to 8,000 readings; flexible display
Tweener
Handheld
Chub-E4
1529
Super-Thermometers
1594A
SPRTs, PRTs, Thermistors
± 0.00006 °C
Ratio accuracy of 0.8 ppm; temperature-controlled internal reference
resistors; six input channels
1595A
SPRTs, PRTs, Thermistors
± 0.000015 °C
Ratio accuracy of 0.2 ppm; Ratio Self-Calibration; automated zero-power
measurements
Multi-channel
1586A
PRTs, Thermistors,
± 0.005 °C
40 channels with scan rate of 10 channels per second
Thermocouples
1560
Accepts any combination of the modules below; all are easily added to and removed from the 1560 Black Stack base
14
2560
SPRTs, PRTs
2561
HTPRTs
2562
PRTs
2563
Thermistors
2564
Thermistors
2565
Thermocouples
2566
Thermocouples
2567
1000 Ω PRTs
2568
1000 Ω PRTs
Thermo-hygrometer
±
±
±
±
±
±
±
±
±
1620A
Two channels measure ambient temperature to ± 0.125 °C and %RH to ±1.5 %. Onboard
memory holds up to two years of time/date-stamped readings. Visual and audio alarms.
Detachable sensors contain their own calibration data for easy recalibrations. Ethernet and
wireless capabilities.
The “DewK” ThermoHygrometer
0.005 °C
0.013 °C
0.01 °C
0.0013 °C
0.0025 °C
0.05 °C
0.1 °C
0.006 °C
0.01 °C
Temperature Calibration
2 channels of 25W or 100W PRTs
2 channels to 1200 °C
8 channels of 2-, 3-, or 4-wire RTDs
2 channels of resolution to 0.0001 °C
8 channels for data acquisition
Reads most TC types with 0.0001 mV resolution
Reads any combination up to 12 channels of virtually any type of TC
2 channels of high-resistance PRTs
8 channels of high-resistance PRTs
www.flukecal.com
Thermometer probes
Platinum resistance thermometers (PRTs)
Model
Range
Size
Basic Accuracy†
Secondary standard PRT
5608-9-X
–200 °C to 500 °C
9 in x 1/8 in
5608-12-X
–200 °C to 500 °C
12 in x 1/8 in
5609-12-X
–200 °C to 670 °C
12 in x 1/4 in
5609-15-X
–200 °C to 670 °C
15 in x 1/4 in
5609-20-X
–200 °C to 670 °C
20 in x 1/4 in
5609-300-X
–200 °C to 670 °C
300 mm x 6 mm
5609-400-X
–200 °C to 670 °C
400 mm x 6 mm
5609-500-X
–200 °C to 670 °C
500 mm x 6 mm
5626
–200 °C to 661 °C
305 or 381 x 6.35 mm (12 or 15 x 0.25 in
± 0.007 °C at 0 °C
5628
–200 °C to 661 °C
305 or 381 x 6.35 mm (12 or 15 x 0.25 in)
± 0.006 °C at 0 °C
Select from available
calibration options
Secondary reference PRT
5616-12
–200 °C to 420 °C
6.35 mm x 298 mm (0.250 x 11.75 in)
± 0.010 °C at 0.010 °C
5615-6
–200 °C to 300 °C
4.76 mm x 152 mm (0.188 x 6.0 in)
± 0.013 °C at 0.010 °C
5615-9
–200 °C to 420 °C
4.76 mm x 229 mm (0.188 x 9.0 in)
± 0.013 °C at 0.010 °C
5615-12
–200 °C to 420 °C
6.35 mm x 305 mm (0.250 x 12.0 in)
± 0.013 °C at 0.010 °C
Precision industrial PRT
5627A-6
–200 °C to 300 °C
152 mm x 4.7 mm (6 x 0.187 in)
± 0.05 °C at 0 °C
5627A-9
–200 °C to 300 °C
229 mm x 4.7 mm (9 x 0.187 in)
± 0.05 °C at 0 °C
5627A-12
–200 °C to 420 °C
305 mm x 6.35 mm (12 x 0.25 in)
± 0.05 °C at 0 °C
5622-05
–200 °C to 350 °C
100 mm x 0.5 mm
± 0.04 °C at 0 °C
5622-10
–200 °C to 350 °C
100 mm x 1.0 mm
± 0.04 °C at 0 °C
5622-16
–200 °C to 350 °C
200 mm x 1.6 mm
± 0.04 °C at 0 °C
5622-32
–200 °C to 350 °C
200 mm x 3.2 mm
± 0.04 °C at 0 °C
Fast response PRT
Small diameter industrial PRTs
5618B-6
–200 °C to 300 °C
152 mm x 3.2 mm (6 x 0.125 in)
± 0.05 °C
5618B-9
–200 °C to 500 °C
229 mm x 3.2 mm (9 x 0.125 in)
± 0.05 °C
5618B-12
–200 °C to 500 °C
305 mm x 3.2 mm (12 x 0.125 in)
± 0.05 °C
5606 Immersion PRT
–200 °C to 160 °C
50 mm x 3.1 mm ( 2 x 1/8 in)
± 0.05 °C
5623B Freezer Probe
–100 °C to 156 °C
152 mm x 6.35 mm (6 x 0.25 in)
± 0.05 °C
0 °C to 1000 °C
508 mm x 6.35 mm (20 x 0.l25 in)
± 0.055 °C
5640
0 °C to 60 °C
229 mm x 6.35 mm (9 x 0.25 in)
± 0.0015 °C
5641
0 °C to 60 °C
114 mm x 3.2 mm (4.5 x 0.125 in)
± 0.001 °C
5642
0 °C to 60 °C
229 mm x 3.2 mm (9 x 0.125 in)
± 0.001 °C
5643
0 °C to 100 °C
114 mm x 3.2 mm (4.5 x 0.125 in)
± 0.0025 °C
5644
0 °C to 100 °C
229 mm x 3.2 mm (9 x 0.125 in)
± 0.0025 °C
5610
0 °C to 100 °C
152 mm or 229 x 3.2 mm (6 or 9 x 0.125 in)
± 0.01 °C
5611A
0 °C to 100 °C
1.5 mm (0.06 in) tip dia.
± 0.01 °C
5611T
0 °C to 100 °C
28 mm x 3 mm (1.1 x 0.12 in)
± 0.01 °C
5665
0 °C to 100 °C
76 mm x 3.2 mm (3 x 0.125 in)
± 0.01 °C
Full immersion PRTs
High temperature PRT
5624
Thermistors
Standards
Secondary probes
Thermocouples
Type R and S standards
5649/5650-20
0 °C to 1450 °C
508 mm x 6.35 mm (20 x 0.25 in)
± 0.7 °C at 1100 °C
5649/5650-20C
0 °C to 1450 °C
508 mm x 6.35 mm (20 x 0.25 in)
± 0.7 °C at 1100 °C
5649/5650-25
0 °C to 1450 °C
635 mm x 6.35 mm (20 x 0.25 in)
± 0.7 °C at 1100 °C
5649/5650-25C
0 °C to 1450 °C
635 mm x 6.35 mm (20 x 0.25 in)
± 0.7 °C at 1100 °C
†“Basic Accuracy” includes calibration uncertainty and short-term repeatability. It does not include long-term drift.
www.flukecal.com
Temperature Calibration
15
Calibration baths
Compact calibration baths
Model
Range
Stability
Depth
6330
35 °C to 300 °C
± 0.005 °C at 100 °C
± 0.015 °C at 300 °C
234 mm (9.25 in)
7320
–20 °C to 150 °C
± 0.005 °C at –20 °C
± 0.005 °C at 25 °C
234 mm (9.25 in)
7340
–40 °C to 150 °C
± 0.005 °C at –40 °C
± 0.005 °C at 25 °C
234 mm (9.25 in)
7380
–80 °C to 100 °C
± 0.006 °C at –80 °C
± 0.010 °C at 0 °C
178 mm (7 in)
6331
35 °C to 300 °C
± 0.015 °C at 300 °C
± 0.005 °C at –20 °C
457 mm (18 in)
7321
–20 °C to 150 °C
± 0.005 °C at 25 °C
± 0.005 °C at –40 °C
457 mm (18 in)
7341
–45 °C to 150 °C
± 0.005 °C at –40 °C
± 0.005 °C at 25 °C
457 mm (18 in)
7381
–80 °C to 110 °C
± 0.006 °C at –80 °C
± 0.005 °C at 0 °C
457 mm (18 in)
Standard size calibration baths
7080
–80 °C to 110 °C
± 0.0025 °C at –80 °C
± 0.0015 °C at 25 °C
305 mm (12 in)
7008
–5 °C to 110 °C
± 0.0007 °C at 25 °C
± 0.0008 °C at 0 °C
331 mm (13 in)
7011
–10 °C to 110 °C
± 0.0008 °C at 25 °C
± 0.0008 °C at 0 °C
305 mm (12 in)
7040
–40 °C to 110 °C
± 0.0015 °C at 25 °C
± 0.001 °C at 40 °C
305 mm (12 in)
6020
40 °C to 300 °C
± 0.005 °C at 300 °C
± 0.001 °C at 40 °C
305 mm (12 in)
6022
40 °C to 300 °C
± 0.005 °C at 300 °C
± 0.001 °C at 40 °C
464 mm (18.25 in)
6024
40 °C to 300 °C
± 0.005 °C at 300 °C
± 0.002 °C at 200 °C
337 mm (13.25 in)
6050H
180 °C to 550 °C
± 0.007 °C at 500 °C
± 0.006 °C at –80 °C
305 mm (12 in)
Other
16
Item
Description
Bath
accessories
Stands, rods, and clamps to suspend and support your probes and thermometers
Bath fluids
Silicone oils, salt, and cold fluids in convenient, small quantities.
Rosemount
bath
controllers
Model 7900 controller designed by Hart integrates the features of Hart’s 2100 controller and can
be used in place of the Rosemount 915 controller with Rosemount-designed baths.
Fluke
Calibration
bath
controllers
Model 2100 and 2200 controllers can be integrated with homemade baths or other heat sources
to achieve performance levels approaching Fluke Calibration baths.
Temperature Calibration
www.flukecal.com
Industrial temperature calibrators
Field metrology wells
Model
Range
Accuracy
9142
–25 °C to 150 °C
± 0.2 °C
9143
33 °C to 350 °C
± 0.2 °C
9144
50 °C to 660 °C
± 0.35 °C at 50 °C
± 0.35 °C at 420 °C
± 0.5 °C at 660 °C
6102
35 °C to 200 °C (95 °F to 392 °F)
± 0.25 °C
7102
–5 °C to 125 °C (23 °F to 257 °F)
± 0.25 °C
7103
–30 °C to 125 °C (–22 °F to 257 °F)
± 0.25 °C
9100S
35 °C to 375 °C (95 °F to 707 °F)
± 0.25 °C at 100 °C
± 0.5 °C at 375 °C
9102S
–10 °C to 122 °C (14 °F to 252 °F)
± 0.25 °C
9009
–15 °C to 350 °C (5 °F to 662 °F)
Cold block: ±0.2 °C
Hot block: ±0.6 °C
9103
–25 °C to 140 °C (–13 °F to 284 °F)
± 0.25 °C
9140
35 °C to 350 °C (95 °F to 662 °F)
± 0.5 °C
9141
50 °C to 650 °C (122 °F to 1202 °F)
± 0.5 °C to 400 °C
± 1 °C to 650 °C
4180
–15 °C to 120 °C
±
±
±
±
±
0.40
0.40
0.50
0.50
0.55
°C
°C
°C
°C
°C
at
at
at
at
at
–15 °C
0 °C
50 °C
100 °C
120 °C
4181
35 °C to 500 °C
±
±
±
±
±
0.35
0.50
0.70
1.20
1.60
°C
°C
°C
°C
°C
at
at
at
at
at
35 °C
100 °C
200 °C
350 °C
500 °C
9132
50 °C to 500 °C (122 °F to 932 °F)
± 0.5 °C at 100 °C
± 0.8 °C at 500 °C
9133
–30 °C to 150 °C (–22 °F to 302 °F)
± 0.4 °C
9170
–45 °C to 140 °C (–49 °F to 284 °F)
± 0.1 °C
9171
–30 °C to 155 °C (–22 °F to 311 °F)
± 0.1 °C
9172
35 °C to 425 °C (95 °F to 797 °F)
± 0.1 °C at 100 °C
± 0.15 °C at 225 °C
± 0.2 °C at 425 °C
9173
50 °C to 700 °C (122 °F to 1292 °F)
± 0.2 °C at 425 °C
± 0.25 °C at 660 °C
0 °C (32 °F)
± 0.05 °C
50 °C to 670 °C (122 °F to 1238 °F)
± 0.15 °C at 100 °C
± 0.65 °C at 600 °C
–30 °C to 140 °C (–22 °F to 284 °F )
± 0.25 °C (insert wells)
± 0.65 °C (fixed wells)
Micro-Baths
Handheld dry-wells
Field dry-wells
Infrared calibrators
Metrology Wells
Zero point dry-well
9101
Dual block dry-well
9011
Thermocouple furnaces
9150
150 °C to 1200 °C (302 °F to 2192 °F)
www.flukecal.com
± 0.5 °C
Tempreature Calibration
17
5681, 5683, 5684, and 5685
5698-25
ITS-90
5686-B
5699
Standard
Platinum
Resistance
Thermometers
(SPRTs)
5681, 5683, 5684, and
5685 Quartz-Sheath SPRTs
The performance you expect from
world-class SPRTs.
• Drift rates as low as 0.0005 K
• Proprietary gas mixtures
ensures high stability
• Most experienced SPRT design
team in the business
5698-25 Working Standard
SPRT
High performance-to-price ratio.
• Conforms to ITS-90 SPRT
Guidelines
• Drift rate typically 0.003 °C
• Calibration options by fixed
point
5686-B Glass Capsule SPRT
Designed for metrology work
requiring small SPRTs.
• Temperatures from -260 °C
(13 K) to 232 °C
• Stability typically 0.001 °C
over 100 °C range
• Miniature capsule package
eliminates stem conduction
5699 High-Temperature
Metal-Sheath SPRT
5901
ITS-90 FixedPoint Cells
Mini Fixed-Point Cells
5901 Triple Point of Water
Cells
Must-have, primary temperature
standards.
• Easy-to-use, inexpensive
standard with uncertainty
better than ± 0.0001 °C
• Four sizes and two shells
(glass and quartz) to choose
from
• Isotopic composition of Vienna
Standard Mean Ocean Water
ITS-90 Fixed-Point Cells
Best cell uncertainties commercially available.
• Every ITS-90 fixed point
available from mercury to
copper
• Plateaus last days (gallium for
weeks and TPW for months)
• Manufactured and tested by
Fluke Calibration’s primary
standards scientists
Mini Fixed-Point Cells
Least expensive, easiest-to-use
fixed-point standards.
• Lower uncertainties than comparison calibrations
• All ITS-90 fixed points from
TPW to copper
• Reduced equipment and
annual recalibration costs
Affordable working standard
SPRT.
• Range to aluminum point
(660 °C)
• Inconel™ sheaths guard
against contamination of
sensor
• Drift rates less than 8 mK/year
18
Temperature Calibration
www.flukecal.com
9114, 9115A, 9116A
9117
7196B
Cell Maintenance Apparatus
9210
9114, 9115A, 9116A FreezePoint Furnaces
7012/7312 Triple Point of
Water Maintenance Baths
Designed for maximum-length
plateaus.
• Designed to extend plateaus
• High-stability OEM controllers,
RS-232 included
• External cooling coils
Keep your cells up and running
reliably for weeks at a time.
• Maintains TPW cells for up to
six weeks
• Optional immersion freezer for
simple cell freezing
• Up to 496 mm (19.5 in) of
immersion depth
9210 Mini Triple Point
of Water Maintenance
Apparatus
9230
Simple supercool-and-shake
realization and maintenance of
the 5901B Mini TPW Cell.
• Easy preprogrammed
realization
• Inexpensive fixed-point
solution
• Training complete in less than
an hour
9230 Gallium Cell
Maintenance Apparatus
Realize and maintain the melting
point of the 5943 Gallium Cell.
• One week plateau duration
• No hassle automatic
realizations
• Used daily in our Primary Lab
9260
9117 Annealing Furnace
Keeps SPRTs and PRTs performing at their highest levels.
• Relieves mechanical strain
• Guards against contamination
• Anneals both SPRTs and
HTSPRTs
7196B LN2 Comparison
Calibrator
Lowest-cost calibration to
-196 °C.
• Simple to use
• Uncertainty less than 2 mK
9260 Mini Fixed-Point Cell
Furnace
Inexpensive, easy-to-use fixedpoint maintenance apparatus.
• Realize and maintain In, Sn, Zn
and Al fixed-point cells
• Good introduction to fixedpoint calibration
• User friendly and inexpensive
7312
www.flukecal.com
Temperature Calibration
19
1586A
1620A
Thermometer Readouts
1594A/1595A
5430
1560
1586A Super-DAQ Precision
Temperature Scanner
1529 Chub-E4 Standards
Thermometer
Best-in-class temperature measurement accuracy and up to
40 isolated input channels for
measuring RTDs, thermocouples,
thermistors, dc Voltage, dc current, and resistance.
• Thermocouple accuracy
(± 0.5 °C)
• Scan speed of up to 10 channels per second
• Real-time color trending—
chart up to four channels
simultaneously
• Control Fluke Calibration
temperature sources such as
dry-wells or micro-baths for
automated calibration routines
Lab-quality accuracy on four
channels for PRTs, thermistors and
thermocouples.
• Four channels for PRTs, thermistors, and thermocouples
• Displays eight user-selected data
fields from any channel
• Logs up to 8,000 readings with
date and time stamps
1594A/1595A SuperThermometers
Thermometry bridge accuracy
combined with time-saving
features.
• Calibrate SPRTs, PRTs, RTDs
and thermistors (0 Ω to 500 kΩ)
• Accuracy as good as 0.06 ppm
(0.000015 °C)
• “Ratio Self-Calibration” verifies
and calibrates resistance ratio
accuracy
1529
5430 Standard AC/DC
Resistor
1502A/1504
Best performance available in an
ac/dc resistor.
• Long-term stability better than
2 ppm/year (< 1 ppm typical)
• Traceable ac and dc calibrations available
• National lab design proven for
more than 25 years
1560 Black Stack
Thermometer Readout
1523/1524
Accurate, expandable and configurable readout.
• Reads SPRTs, RTDs, thermistors, and thermocouples
• Any configuration you like up
to eight modules
• High-accuracy reference thermometer (to ± 0.0013 °C)
1551A Ex and 1552A Ex
20
Temperature Calibration
1502A/1504 Thermometer
Readouts
Best performance thermometers in
their price range.
• Single-channel reference
thermometers
• Two models to choose from—
reading PRTs or thermistors
• Best price/performance package
1523/1524 Reference
Thermometers
Measure, graph and record three
sensor types with one tool.
• High accuracy: PRTs: ± 0.011 °C;
Thermocouples: ± 0.24 °C;
Thermistors: ± 0.002 °C
• A simple user interface to see
trends quickly
• Smart connectors to load probe
information automatically
1551A Ex and 1552A Ex
“Stik” Thermometer
The best substitute for precision
mercury-filled glass thermometers.
• Accuracy of ± 0.05 °C
(± 0.09 °F) over full range
• Intrinsically safe (ATEX and
IECEx compliant)
• Two models to choose from
(-50 °C to 160 °C or -80 °C to
300 °C)
1620A Digital ThermometerHygrometer
The most accurate temperature and
humidity graphical data logger on
the market.
• Superior accuracy
• Network enabled
• Powerful logging and analysis
tools
www.flukecal.com
5616
5608/5609
5626/5628
Secondary Standard
PRTs
5608/5609 Secondary PRTs
Very stable thermometer from
–200 °C to 670 °C.
• 5608: –200 °C to 500 °C
(80 mm minimum immersion)
• 5609: –200 °C to 670 °C
(100 mm minimum immersion)
• Calibration not included,
NVLAP-accredited calibration
optional, lab code 200348-0
5615 Secondary PRT
Reference-grade platinum
sensing element.
• –200 °C to 420 °C
• ± 0.012 °C accuracy at 0 °C
• Drift of ± 0.007 °C after 100
hours at max temperature
5626/5628 Secondary
SPRT, PRT, Temperature
Sensors
High-temperature secondary
standards.
• -200 °C to 661 °C
• Meets all ITS-90 requirements
for resistance ratios
• Rtp drift < 20 mK after 500
hours at 661°C
Secondary Reference
PRTs
5616 Secondary Reference
PRT
• –200 °C to 420 °C
• Excellent stability: ± 0.007 °C
• Calibrated accuracy ± 0.011 °C
at 0 °C
5615
Thermistor Standards
Fast Response PRTs
5640 Series Thermistor
Standards Probes
5622 Fast Response PRTs
High accuracy temperature
probes with excellent stability.
• Accuracy to ± 0.001 °C
• Affordable system accuracy to
± 0.004 °C or better
• NIST-traceable calibration
included from manufacturer
HighTemperature PRT
5624 Platinum Resistance
Thermometer
Precision PRT accuracy at thermocouple temperatures.
• Temperature range of 0 °C to
1000 °C
• Accuracy of ± 0.05 °C to
962 °C (includes short-term
stability and calibration
uncertainty)
• Long-term drift of 0.01 °C at
0 °C after 100 hours at 1000 °C
Thermocouple
Standards
5649/5650 Type R and
Type S Thermocouple
Standards
Eight models to fit any type R or
S thermocouple applications.
• 0 °C to 1450 °C
• Two sizes available, each with
or without reference junction
• Optional fixed-point calibration, uncalibrated accuracy is
the greater of ± 0.6 °C or
± 0.1 % of reading
Precision Industrial PRTs
5627A Precision Industrial
PRTs
Durable PRTs with temperature
range to 420 °C and accuracy to
0.025 °C.
• Vibration and shock resistant
• NVLAP-accredited calibration
included, lab code 200706-0
www.flukecal.com
5640
Designed for temperature
measurements requiring fast
response or short immersion over
a wide range.
• Time constants as fast as
0.4 seconds
• Available as DIN/IEC Class A
PRTs or with NVLAP-accredited
calibration, lab code 200348-0
• Small probe diameters ranging
from 0.5 mm to 3.2 mm
Small Diameter
Indust. PRTs
5618B Small Diameter
Industrial RTD
Secondary level performance
with full ITS-90 calibration.
• Small diameter sheath, 3.2 mm
(0.125 in)
• Excellent stability
• Includes ITS-90 coefficients
5624
5649/5650
5627A
5622
Full Immersion PRTs
5606 Full Immersion PRT
PRTs for laboratory freezers,
autoclaves, and furnaces.
• Transition junction designed
to withstand full temperature
range of probe
• 5606: -200 °C to 160 °C
• Calibration accuracy of
± 0.05 °C
5618B
Secondary Thermistor
Probes
5610/5611/5611T/5665
Secondary Reference
Thermistor Probes
Lab-grade thermistors probes for
accurate work across a narrow
temperature range.
• Short-term accuracy to
± 0.01 °C; one-year drift
< ± 0.01 °C
• Accredited NVLAP calibration
optional
• Flexible Teflon and silicone
coated fast-response models
5606
5610/5611/
5611T/5665
Temperature Calibration
21
7008/7040/7037/7012/7011
6330/7320/7340/7380
6331/7321/7341/7381
Compact
Standard
Calibration Baths Calibration Baths
6330/7320/7340/7380
Compact Temperature
Calibration Baths
6020/6022/6024 High
Temperature Calibration Oil
Baths
Compact baths with the stability and uniformity required for
thermometer calibration.
• Stability and uniformity each
better than ± 0.008 °C
• Metrology-level performance in
lab-friendly sizes
• Convenient use on benchtops
or on matching carts
Stable, uniform heat sources for
calibrations up to 300 °C.
• Stability as good as 0.001°C
• Large-capacity tanks for higher
productivity
• Built-in cooling coils for
external cooling sources
6331/7321/7341/7381
Deep-Well Compact Baths
Ample immersion depth and
great stability, in a high value
compact bath.
• 457 mm (18 in) of depth with
just 15.9 liters (4.2 gal) of fluid
• Perfect for liquid-in-glass thermometers with optional LIG kit
• Fast, quiet, compact (yet deep),
and economical
7312 Triple Point of Water
Maintenance Bath
7312
7080
Keep your cells up and running
reliably for weeks at a time.
• Maintains TPW cells for up to
six weeks
• Optional immersion freezer for
simple cell freezing
• Independent cutout circuit
protects cells from breaking
6020/6022/6024
6050H Extremely High
Temperature Calibration
Salt Bath
Designed for high-temperature
calibration—up to 550 °C.
• Eliminates messy sand baths
• Electronically adjustable
temperature cutouts
• Stability of ± 0.008 °C at
550 °C
7008/7040/ 7037/
7012/7011 Cold
Temperature Calibration
Baths
High stability means low calibration uncertainties—no other bath
performs this well.
• Stability to ± 0.0007 °C
• Best digital temperature controller available
• “Super Tweak” function provides set-point resolution to
0.00003 °C
7080 Really Cold
Temperature Calibration
Baths
Cool to –40, –60, or –80 °C without external coolants.
• Self-contained refrigeration—
no LN2 or chiller required
• Temperatures as low as –80 °C
in real metrology baths
• Stability of ± 0.0025 °C at
–80 °C
6050H
22
Temperature Calibration
www.flukecal.com
2100 and 2200
6054/6055/7007
7900
Bath Controllers
2100 and 2200 Benchtop
Temperature Controllers
7009/7108/7015
Special
Application
Baths
6054/6055/7007
Deep-Well Baths
Most stable temperature controllers available.
• Resolution as high as
0.00018 °C
• RS-232 interface included for
automating applications
7900 Controller for
Rosemount-Designed Baths
All the features of the Fluke Calibration 2100 Controller.
• Installs easily
• Two independent overtemperature cutout circuits
9170/9171/9172/9173
Metrology Wells
9170/9171/9172/9173
Metrology Well Calibrators
Accurate enough for lab use yet
rugged and portable.
• Best-performing industrial heat
sources (accuracy, stability,
uniformity) in the world
• –45 °C to 700 °C
• Immersion depth to 203 mm
(8 in)
• Optional ITS-90 reference input
reads PRTs to ± 0.006 °C
Extra-deep wells for thermometry
work requiring extra tank depth
and ultimate stability.
• Constant liquid levels through
concentric-tube design
• Special design for sighting LIG
thermometers
• Depth up to 60 cm (24 in)
7009/7108/7015
Resistor Baths
Three size options for any quantity of resistors.
• Stability to ± 0.0007 °C
• Independent high- and lowtemperature cutout circuit
www.flukecal.com
Temperature Calibration
23
9190A
9142/9143/9144
9100S/9102S
Field Metrology
Wells
Field Dry-Well
Calibrators
9190A Ultra-Cool Field
Metrology Well
9103/9140/9141 Field
Dry-Well Calibrators
Ultra-cool dry-block calibrator
with best-in-class stability.
• Wide temperature range from
–95 °C to 140 °C
• Best-in-class stability:
± 0.015 °C full range
• Accuracy using built-in reference thermometer readout:
± 0.05 °C full range
• Display accuracy: ± 0.2 °C full
range
Great performance in portable
instruments.
• Lightweight and very portable
• Accuracy to ± 0.25 °C
• RS-232 and Interface-it
software included
9142/9143/9144 Field
Metrology Wells
9011
Small dry wells for big field
applications.
• Lightweight, portable, and fast
• Cool to –25 °C in 15 minutes
and heat to 660 °C in 15
minutes
• Built-in two-channel readout
for PRT, RTD, thermocouple,
4-20 mA current
Dual-Block
Dry-Well
9103/9140/9141
9011 High-Accuracy
Dual-Well Calibrator
Widest temperature range available in a single dry-well.
• Combined range from –30 °C to
670 °C, one unit—two blocks
• Two independent temperature
controllers (hot and cold side)
• Stability to ± 0.02 °C
6102/7102/7103
24
9009
Temperature Calibration
Micro-Baths
6102/7102/7103
Micro-Bath Thermometer
Calibrators
Portable and extremely stable.
• World’s smallest portable
calibration baths
• Calibrates sensors of any size
or shape
• Stability to ± 0.015 °C
Handheld
Calibrators
9100S/9102S Handheld
Dry-Wells
World’s smallest, lightest and
most portable dry-wells.
• Smallest dry-wells in the
world
• Ranges from –10 °C to 375 °C
• Accuracy to ± 0.25 °C, stability
of ± 0.05 °C at 0 °C
9009 Industrial Dual-Block
Thermometer Calibrator
Double your productivity or cut
your calibration time in half.
• Temperatures from –15 °C to
350 °C in one unit
• Two wells in each block for
simultaneous comparison
calibrations
• Rugged, lightweight, waterresistant enclosure
www.flukecal.com
4180/81
9132 and 9133
Infrared
Calibrators
Surface Probe
Calibrator
4180/81 Precision Infrared
Calibrators
3125 Surface Probe
Calibrator
Accredited performance for pointand-shoot calibrations.
• Calibrated radiometrically for
meaningful, consistent results.
• Accredited calibration included
• Accurate, reliable performance
from –15 °C to 500 °C
Milled aluminum for a smooth
and true calibration work
area with maximum thermal
conductivity.
• Calibrates surface sensors up
to 400 °C
• Uses Fluke Calibration 2200
Controller for excellent accuracy and stability
• NIST-traceable calibration
included
9132 and 9133 Portable
Infrared Calibrators
Precision when you need it for
infrared temperature calibration.
• Certify IR pyrometers from
–30 °C to 500 °C (–22 °F to
932 °F)
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact
temperature measurement
Zero-Point
Dry-Well
9101 Series Metrology
Well Calibrators
Thermocouple
Furnaces
9150
9101
9150 Thermocouple Furnace
Convenient, portable thermocouple furnace.
• 150 °C to 1200 °C
• Stability of ± 0.5 °C over full
range
• NIST-traceable calibration
included
• RS-232 port standard
3125
Ice-point reference without
the ice.
• ± 0.005 °C stability in a
portable ice-point reference
• Easy re-calibration for longterm reliability
• Ready light frees user’s time
and attention
www.flukecal.com
Temperature Calibration
25
Pressure calibration
Pressure calibration is the comparison of the
output of a device used to measure pressure with
that of another pressure measurement device,
or pressure measurement standard. This usually
involves plumbing the unit under test (UUT) to
the standard device and generating a common
pressure in the measurement circuit. The outputs
of the devices are compared at one or more
pressures, typically from the lowest to highest
readings of the UUT’s full scale range, or the
range over which it is normally used. The comparison process can be performed in
a chain from the highest level of fundamental
pressure realization down to everyday pressure
measurement devices, such as analog gauges,
transducers and transmitters, to ensure that
pressure measurements are accurate and comply
with accepted or mandated standards.
26
Pressure Calibration
The test fluid inside a pressure calibration
system may be liquid or gas depending on the
application. In general, gas (usually compressed
nitrogen or air) is used for cleanliness and
precision at lower pressures, and liquids (usually
oil or water) are often used for safety, leak
integrity, and ease of pressure generation at
higher pressures above 7 MPa to 21 MPa (1000 psi
to 3000 psi). There is a great deal of overlap in
the actual ranges for which liquid or gas may be
used practically, as reflected in the range of Fluke
Calibration instruments that are specialized for
each type of test fluid.
www.flukecal.com
Product highlights
4322 Automated Pressure
Calibrator
2700G Series Reference
Pressure Gauges
3130 Portable Pressure
Calibrator
Reliable performance across a
wide pressure range
Best-in-class measurement
performance in a rugged, easyto-use, economical package.
The 3130 packs everything
you need for accurate calibration of pneumatic field
instrumentation into a rugged
case suitable for harsh industrial environments.
• Measure and generate pressures from vacuum to 2 MPa
(300 psi, 20 bar)
• Internal pump can generate
vacuum to -80 kPa (-12 psi,
-0.8 bar) or pressure to 2 MPa
(300 psi, 20 bar)
• Supply pressure connection
allowing the use of external gas supply up to 2 MPa
(300 psi, 20 bar)
• Includes variable volume for
fine adjustment of pressures
• Pressure measurement accuracy of 0.025 % reading
± 0.01 % FS
• Electrical measurement and
24 volt supply for close looped
calibrations
• Measure or generate 4 mA to
20 mA
• Measure 0 to 30 V dc
• Powered by internal,
rechargeable, high capacity
NiMH battery or universal ac
mains adapter
• Compatible with Fluke 700P
Pressure Modules
• Rugged, lightweight, compact
components for use on the
bench or in-situ
• Precise automated pressure
control from vacuum to 70 MPa
gauge (10k psi)
• Greater of 0.1 % of reading or
25 Pa (0.1 in H2O) accuracy
across the entire pressure
range
• Gauge, vacuum (negative
gauge), compound and absolute
modes
• Onboard pressure/vacuum generation from 3.5 kPa (0.5 psi)
absolute to 2 MPa (300 psi)
• Simple, intuitive GUI steps
users through calibration of
pressure gauges, transducers
and switches
• Integrated contamination prevention system allows direct
calibration of hydraulic devices
without cleaning
• Electrically-driven intensifier
provides on-demand supply to
70 MPa (10 k psi)
www.flukecal.com
Improved measurement accuracy
allows the 2700G to be used for
a wide variety of applications.
It is ideal for calibrating pressure measurement devices such
as pressure gauges, transmitters, transducers, and switches.
In addition, it can be used as
a check standard or to provide
process measurements with data
logging.
• Precision pressure measurement from 100 kPa (15 psi) to
70 MPa (10,000 psi)
• Accuracy to 0.02 % of full scale
• Easy-to-use, rugged construction for reliable performance
• Combine with the 700PTPK
or 700HTPK pump kits for a
complete portable pressure
testing solution for up to 4 MPa
(600 psi) with the PTP-1 pneumatic pump and up to 70 MPa
(10 000 psi) with the HTP-2
hydraulic pump
• Combine with the P5510,
P5513, P5514, or P5515
Pressure Comparators for a
complete bench top pressure
calibration solution
• Test port is 1/4 NPT Male. 1/4
BSP and M20 X 1.5 adapters
are included standard
• USB communications cable
and universal power supply
included standard
Pressure Calibration
27
Selection guide
Gas Pressure Calibrators
This selection guide presents only some of the Fluke Calibration gas pressure calibration
line. Other, higher accuracy, solutions are available for all pressure ranges.
Automated
7M
1.4M
100K
14M
6242
7M
PPC4Ex
6241
1.4M
100K
15K
P3032
P3031
P3025
P3023
P3022
P3015
P3014
P3013
P3012
P3011
Deadweight testers
PPC4E
14M
Manual
Workload
Gauges/sensors
Gage
Absolute
Bidirectional*
Pressure range
Vacuum
90 % vacuum
–ATM to maximum sensor
range**
Absolute pressure
0.15 psi (1 kPa) to maximum
sensor range
0.5 psi (3.5 kPa) to maximum
sensor range
1 psi (7 kPa) to maximum
sensor range
Positive gage pressure
5 inH₂O (1.5 kPa)
12 inH₂O (3 kPa)
1.5 psi (10.3 kPa)
2 psi (13.8 kPa)
2.2 psi (15 kPa)
3 psi (20.7 kPa)
5 psi (34.4 kPa)
10 psi (68.9 kPa)
15 psi (103.4 kPa)
20 psi (137.9 kPa)
30 psi (200 kPa)
40 psi (275.8 kPa)
100 psi (.7 MPa)
150 psi (1 MPa)
200 psi (1.4 MPa)
300 psi (2 MPa)
500 psi (3.4 MPa)
600 psi (4 MPa)
1000 psi (7 MPa)
2000 psi (14 MPa)
Accessories
Hand pump
Fine Inc. Weights
*Requires vacuum pump
=Optional
** ATM represents the current atmospheric pressure
–ATM is the lowest pressure achievable in negative gage mode
0.02 % auto-ranged span
0.0015 % FS
0.015 % reading uncertainty
0.0002 % instrument Span
.002 % instrument span
28
Pressure Calibration
www.flukecal.com
Selection guide
Hydraulic Pressure Calibrators
This selection guide presents only some of the Fluke Calibration hydraulic pressure
calibration line. Other, higher accuracy, solutions are available for all pressure ranges.
Manual
Semi Automated
Deadweight Testers
EDWT Electronic Deadweight Tester
200M
140M
70M
200M
140M
6532
70M
40M
20M
14M
7M
P3224
P3223
P3214
P3213
P3211
P3860
P3840
P3830
P3125
P3124
P3123
P3116
P3115
P3114
P3113
P3112
P3111
6531
Fluid type
Oil
Water
Workload
Gauges/sensors*
Gage
Pressure range
10 psi (68.9 kPa)
15 psi (103.4 kPa)
20 psi (137.9 kPa)
30 psi (200 kPa)
40 psi (275.8 kPa)
100 psi (.7 MPa)
150 psi (1 MPa)
200 psi (1.4 MPa)
300 psi (2 MPa)
500 psi (3.4 MPa)
600 psi (4 MPa)
1000 psi (7 MPa)
2000 psi (14 MPa)
3000 psi (20 MPa)
5000 psi (35 MPa)
6000 psi (40 MPa)
10000 psi (70 MPa)
16000 psi (110 Mpa)
20000 psi (140 MPa)
30000 psi (200 MPa)
40000 psi
(275.8 MPa)
60000 psi (400 MPa)
0.015 % reading uncertainty
0.002 % full scale uncertainty
0.0015 % full scale uncertainty
0.0075 psi (0.05 kPa) uncertainty
0.0002 % span uncertainty
www.flukecal.com
Pressure Calibration
29
7250LP
Gas Pressure
Controllers/
Calibrators
7250LP Low Pressure Controller/
Calibrator
Specialized measurement and control for
very low draft pressure range.
• Precision: 0.005 % of reading
• Control stability: 0.004 % of each range
• Resolution to 0.0001 in H 2O
• Full scale ranges from 0 to 10 in H 2O
(2.5 kPa) to 0 to 100 in H 2O (25 kPa)
7250/7250i Gas Pressure
Controllers/Calibrators
Combining advanced precision, stability,
speed and affordability.
• Pressure ranges from 0 to 40 kPa and
to 21 MPa (0 to 5 psi and to 3000 psi,
0 to 400 mbar and to 210 bar)
• Model 7250i provides precision of
0.005 % of reading
• Model 7250 provides 0.003 % of full
scale precision
• Stability: 0.0075 % of reading per year
• Time to setpoint: 15 seconds with no
overshoot
7250xi High Performance Gas
Pressure Controllers/Calibrators
Unmatched precision and speed.
• Pressure ranges from 0 to 40 kPa and
to 17 MPa (0 to 5 psi and to 2500 psi,
0 to 400 mbar and to 170 bar)
• Advanced precision of 0.005 % of reading from 5 % to 100 % of full scale
• Stability: 0.0075 % of reading per year
• Time to setpoint: 15 seconds with no
overshoot
30
7250/7250i
7252/7252i Dual Output
Gas Pressure Controllers
A unique and flexible approach to performing automated calibrations over a
wide pressure range.
• Two independent pressure
measurement and control modules
• Two performance models available,
7252i and 7252
• Fast control: <15 seconds with zero
overshoot
• Full scale ranges from 0 to 2.5 kPa
and to 21 MPa (0 to 0.36 psi and to
3000 psi)
7250xi
7252/7252i
PPC4 Gas Pressure Controller/
Calibrator
Wide rangeability and flexibility in a
single controller. Ranges and accuracy
classes can be selected to best suit the
application.
• Up to two internal Quartz Reference
Pressure Transducers (Q-RPTs) from
absolute (vacuum) to 14 MPa (2000 psi)
• Full-scale standard class Q-RPTs
provide 0.015 % full scale of selected
range measurement uncertainty
• Standard class Q-RPTs provide 0.01 %
reading measurement uncertainty
• Premium class Q-RPTs provide 0.008 %
reading measurement uncertainty
• 4 ppm control precision as low as 1 kPa
(0.15 psia) with large turndown
• Can use RPM4 reference pressure
monitors as integrated remote pressure
references for additional Q-RPT ranges
PPC4E Pressure Controller/
Calibrator
Very wide rangeability and reliability
at a great value, for everyday pressure
calibration.
• Models available with 10:1 or 100:1
accurate measure and control range
turndown for maximum workload
coverage
• Absolute, gauge and bidirectional gauge
modes included in most models
• Gauge calibration measurement uncertainty ± 0.02 % of selected range, with
range options available from ± 1 kPa
(± 0.15 psi) to 14 MPa (2000 psi)
• Absolute range of 1 kPa (0.15 psi) to
14 MPa (2000 psi)
Pressure Calibration
PPC4
PPC4E
*6241 and 6242 PPC4E gas pressure
controller kits feature PPC4E models
and accessories to form a complete
system that covers a very wide
workload.
www.flukecal.com
PPCH-G
7350
High Pressure
Controllers/
Calibrators
Reference
Pressure
Indicators
7350 High Pressure Gas
Controller/Calibrator
RPM4 Reference Pressure
Monitor
Safe, easy-to-use, and effective high pressure test and
calibration.
• Ranges to 70 MPa
(10 k psi, 700 bar)
• Measurement precision to
0.01 % of range
• Control stability 0.007 % FS
Premium measurement performance in a compact and rugged
instrument.
• One or two independent quartz
reference pressure transducer
modules (Q-RPTs) with individual self-defense systems
(SDS™) to prevent over-pressure
• Infinite Ranging and
AutoRange™
• Differential measurement mode
(channel 1- channel 2)
• Dedicated version available
for air data ranges units and
features, RPM4-AD
• Can be used as integrated
external reference pressure
transducer for PPC pressure
controller/calibrators
PPCH-G High Pressure Gas
Controller/Calibrator
Wide rangeability and flexibility
with precise high pressure gas
control.
• Ranges to 100 MPa (15k psi)
• One or two internal Q-RPTs
with large range turndown
• Can use RPM4 reference
pressure monitors as integrated
remote pressure references for
additional Q-RPT ranges
7615 Hydraulic Pressure
Controller/Calibrator
Unique, high speed approach to
high pressure calibration and
testing.
• Ranges to 280 MPa (40 k psi)
• Measurement precision to
0.01 % of range
• Available in a variety of fluids,
including water
• High speed pressure control
PPCH Hydraulic Pressure
Controller/Calibrator
Wide rangeability and flexibility with precise high pressure
hydraulic control.
• Ranges to 200 MPa (30 k psi)
• One or two internal Q-RPTs
with large range turndown
• High precision control over
wide range
• Can use RPM4 reference
pressure monitors as integrated
remote pressure references for
additional Q-RPT ranges
www.flukecal.com
7615
PPCH
7050 Series Digital Pressure
Indicators
Unmatched precision with long
term stability.
• Pressure ranges from
0 to 10 in H 2O and 0 to
1,500 psi (0 to 25 mbar and
0 to 100 bar)
• Model 7050i provides precision
of 0.005 % of reading
• Model 7050 provides 0.003 %
of full scale precision
• Active matrix color screen with
enhanced navigation menus
• Model 7050LP provides
precision of 0.005 % reading
for very low draft pressure
ranges
RPM4
7050
Pressure Calibration
31
PG7601
PG7202
PG7000-AMH
PG7302
2465A
PG7102
Piston Gauges
PG7601 Absolute Gas Piston
Gauge
Gas piston gauge with vacuum
reference for defining absolute
pressures.
• Gas pressure from 5 kPa to
7 MPa (0.7 psi to 1000 psi)
gauge or absolute pressure
• Onboard measurement of test
conditions, and real-time
calculation and display of test
pressure
• Compatible with PPC4 pressure controller and AMH-38
Automated Mass Handler
PG7102 Gas Piston Gauge
Gas piston gauge with 55 kg
mass set for extended range measurement of gauge pressures.
• Gas pressures from 100 kPa
to 11 MPa (15 to 1,600 psig)
• Onboard measurement of test
conditions, and real-time
calculation and display of test
pressure
• Compatible with PPC4 pressure controller and AMH-100
Automated Mass Handler
2470
PG7202 High Pressure Gas
Piston Gauge
2465A Absolute Gas Piston
Gauge
Gas piston gauge with oil-lubricated piston-cylinder for operation
in high pressure gas or oil.
• Gas pressures from 100 kPa to
110 MPa (15 to 16,000 psig),
oil pressures from 100 kPa to
200 MPa (15 to 30,000 psig)
• Gas operated, liquid lubricated
for robust operation and low
piston sink rates
• Onboard measurement of test
conditions, and real-time
calculation and display of test
pressure
• Compatible with PPCH-G pressure controller and AMH-100
Automated Mass Handler
Gas piston gauge capable of very
low pressures, for defining gauge
and absolute pressures.
• Gas pressure from 1.5 kPa to
7 MPa (0.2 psi to 1000 psi)
gauge or absolute pressure
• Lightweight, compact system
with small masses for reduced
bench space, transportability
and ergonomic mass handling
• Compatible with Autofloat
Controller and WinPrompt and
COMPASS software
2470 Gas Piston Gauge
Gas piston gauge capable of very
low to high gauge pressures.
• Pressures ranges from
PG7302 Piston Gauge
1.5 kPa to 20 MPa (0.2 psi
Oil piston gauge for measurement
to 3000 psig)
of high gauge pressures.
• Lightweight, compact system
• Oil pressures from 100 kPa to
with small masses for reduced
500 MPa (15 psi to 75,000 psig)
bench space, transportability
• Onboard measurement of test
and ergonomic mass handling
conditions, and real-time
• Compatible with WinPrompt
calculation and display of test
and COMPASS software
pressure
• Compatible with PPCH pressure controller and AMH-100
Automated Mass Handler
PG7000-AMH Automated
Mass Handler
Automated Mass Handler for
PG7000 Piston Gauges.
• Add to PG7000 Series piston
gauge to fully automate
pressure testing in gauge or
absolute mode
• Designed and tested to provide
years of reliable, maintenance
free operation
• Reduce wear and possible
mass value changes caused by
manual mass handling
32
Pressure Calibration
www.flukecal.com
PG9607/ PG9602
GPC1
Manual Pressure
Generation and
Control
3990 Gas Pressure Control
Pack
MPG2
2482
Precise, manual absolute and
gauge pressure control for gas
piston gauges and indicators.
• Models from vacuum to 7 MPa
and 20 MPa (1000 psi and
3000 psi)
• Self-contained for intuitive,
easy use
GPC1 High Gas Pressure
Controller
OPG1
FPG8601
2482 Differential Piston
Gauge
3990
Specialty Piston
Gauges
PG9607 Gas Piston Gauge
Fully automated primary pressure
reference for absolute and gauge
pressures to 500 kPa.
• Gauge and absolute pressures
from 11 kPa to 500 kPa with a
single piston-cylinder
• Large diameter 50 mm pistoncylinder with improved geometry allows direct traceability
to dimensional measurements
with very low uncertainties
PG9602 Gas Piston Gauge
Fully automated primary pressure
reference for absolute and gauge
pressures to 11 MPa.
• Gauge and absolute pressures
from 10 kPa to 11 MPa
• Up to 100 kg mass load under
vacuum bell jar for large
turndown and overlap of
piston-cylinder ranges
www.flukecal.com
High precision differential pressure measurement at elevated
line pressures.
• Measures differential pressures
using a gas or oil medium
• Differential pressure to 210 kPa
(30 psi, 2100 mbar) at static
line pressure range to 20 MPa
(2900 psi, 200 bar)
• Quickly and easily set differential pressures with lightweight
masses
• Fully automated pressure control and pressure determination
using WinPrompt software
FPG8601 Force-Balanced
Piston Gauge
Gas pressure calibration system
for very low gauge, differential
and absolute pressures.
• Gas pressure from 0 to 15 kPa
(113 Torr) in gauge, differential
and absolute modes
• Measurement uncertainty to
± (5 mPa + 30 ppm of reading)
in gauge and absolute differential mode, ± (8 mPa + 30 ppm
of reading) in absolute mode
• Fully automated, including test
execution, pressure control and
reference and device under test
data collection
Precise, assisted manual control
for high pressure gas piston
gauges and indicators.
• Models to 70 MPa and 110 MPa
(10 k psi and 16 k psi)
• Precise control to full pressure
with simple, ergonomic pushbutton operation
MPG2 Hydraulic Pressure
Generator/Controller
Precise, manual control for
hydraulic piston gauges and
indicators.
• Models to 100 MPa and
200 MPa (15 k psi and 30 k psi)
• Self-contained for intuitive and
easy generation and
precise control to full pressure
OPG1 Hydraulic Pressure
Generator/Controller
Precise, assisted manual control
for hydraulic piston gauges and
indicators.
• Pressure to 200 MPa (30 k psi)
• Precise generation and control
to full pressure with simple,
ergonomic push-button
operation
Pressure Calibration
33
P3000
Industrial
Deadweight Testers
P3000 Pneumatic
Deadweight Tester
P3100
P3200
High performance gas deadweight testers, with unique
suspended piston design for
vacuum calibration.
• 0.015 % of reading accuracy
standard (0.008 % optional)
• 3 to 500 psi (0.2 to 35 bar)
pressure
• Optional low range 0.03 to
1 bar vacuum (1 to 30 inHg)
• Integrated vacuum and pressure pump available to 2 MPa
(300 psi)
P3100 Hydraulic
Deadweight Tester
P3800
Highly accurate oil deadweight
tester, with quick and easyto-use single and dual piston
deadweight models.
• Pressure ranges to 140 MPa
(20 k psi, 1400 bar)
• 0.015 % of reading accuracy
standard (0.008 % optional)
• Built-in pressure generation
and adjustment
• Single or dual piston formats
P3200 Hydraulic
Deadweight Tester
P5510
P5513
Hydraulic deadweight tester specially designed to use water as a
test medium.
• Pressure ranges to 70 MPa
(10 k psi, 700 bar)
• 0.015 % of reading accuracy
standard (0.008 % optional)
• Built-in pressure generation
and adjustment is standard
• Single or dual piston formats
• Water media
P3800 Hydraulic
Deadweight Tester
P5514
High performance and simplicity
for very high pressure hydraulic
calibration.
• Pressure ranges to 400 MPa
(60 k psi, 4000 bar)
• 0.02 % of reading accuracy
standard (0.015 % optional)
• Includes hand pump and
intensifier for generating and
adjusting high pressures
P5514
with 2700G
Pressure
Comparators
P5510 Pneumatic Pressure
Comparator*
Precise, cost effective solution
for checking pressure measuring
instruments to 300 psi (20 bar).
• Dual pressure/vacuum
capability
• Pressure to 20 MPa (300 psi,
20 bar)
• Vacuum from 0 to 80 kPa
(0 to 24 inHg, 800 mbar)
• Built-in pressure and vacuum
generation
P5513 Pneumatic Pressure
Comparator*
Precise, cost effective solution
for checking pressure measuring instruments to 3,000 psi
(7210 bar).
• Pressure range 0 to 210 MPa
(3 k psi, 210 bar)
• High pressure pneumatic
operation
• Screw press for fine pressure
adjustments
• High quality needle valves for
fine control
P5514 and P5515 Series
Hydraulic Pressure
Comparators*
Quick and easy solutions for
checking pressure measuring instruments to 10,000 psi
(700 bar).
• Compatible with a wide range
of fluids
• P5514 Test Pump generates
pressures to 70 MPa (10 k psi,
700 bar)
• P5515 Test Pump generates
pressures to 140 MPa (20 k psi,
1400 bar)
• P5515 has a built-in hand
pump for system priming and
large volume applications
P5515
* Can be used with the 2700G Reference Pressure Gauge to provide a complete calibration solution
34
Pressure Calibration
www.flukecal.com
Pressure
Calibrators
4322 Automated Pressure
Calibrator
•Rugged, lightweight, compact
components for use on the
bench or in-situ
•Precise automated pressure
control from vacuum to 70 MPa
gauge (10,000 psi)
•Greater of 0.1 % of reading or
25 Pa (0.004 psi, 0.1 in H2O)
accuracy across the entire
pressure range
•Onboard pressure/vacuum
generation from 3.5 kPa (0.5
psi) absolute to 2 MPa (300 psi)
3130 Portable Pressure
Calibrator
Everything you need to generate,
control and measure pressure,
as well as read the output of the
device under test (DUT).
• Measure and generate pressures from vacuum to 2 MPa
(300 psi, 20 bar)
• Internal pump can generate
vacuum to -80 kPa (-12 psi,
-0.8 bar) or pressure to 2 MPa
(300 psi, 20 bar)
• Supply pressure connection
allowing the use of external gas supply up to 2 MPa
(300 psi, 20 bar)
• Includes variable volume for
fine adjustment of pressures
• Pressure measurement
accuracy of 0.025 % reading
± 0.01 % FS
• Electrical measurement and
24 volt supply for close looped
calibrations
• Measure or generate 4 mA to
20 mA
• Measure 0 to 30 V dc
• Powered by internal, rechargeable, high capacity NiMH
battery or universal ac mains
adapter
• Compatible with Fluke 700P
Pressure Modules
www.flukecal.com
E-DWT-H Electronic
Deadweight Tester
A digital alternative to the traditional deadweight tester.
• Set and measure pressure
precisely without limitation of
mass loading resolution
• Pressure measurement is
insensitive to local gravity and
orientation
• One year uncertainty of
± 0.02 % of reading
• Run onboard test routines
and store calibration data for
review and export to a PC
4322
2700G Series Reference
Pressure Gauges
Best-in-class measurement
performance in a rugged, easyto-use, economical package.
• Precision pressure measurement from 100 kPa (15 psi) to
70 MPa (10,000 psi)
• Accuracy to 0.02 % of full scale
• Easy-to-use, rugged construction for reliable performance
• Combine with the 700PTPK
or 700HTPK pump kits for a
complete portable pressure
testing solution for up to 4 MPa
(600 psi) with the PTP-1 pneumatic pump and up to 70 MPa
(10,000 psi) with the HTP-2
hydraulic pump
• Combine with the P5510,
P5513, P5514, or P5515
Pressure Comparators for a
complete bench top pressure
calibration solution
• Test port is 1/4 NPT Male. 1/4
BSP and M20 X 1.5 adapters
are included standard
• USB communications cable
and universal power supply
included standard
3130
E-DWT-H
2700G
Pressure Calibration
35
Air Data Calibration
7750i Air Data Calibrator
7750i
Air data test set with unequalled
precision and long term stability and superior pressure control
technology.
• High accuracy, RVSM compliant
• Accuracy to ± 2 feet, 0.02
knots
• True differential sensor for
airspeed (Qc)
RPM4-AD Reference
Pressure Monitor
RPM4-AD
2468A
ADCS-601
Specialized pressure indicator
for the absolute and differential pressure ranges in air data
instruments.
• Fixed wing and rotary wing
range versions
• True Pt, Ps, Qc operation
2468A Pitot/Static Primary
Standard
Gas piston gauge specialized for
air data absolute and differential
pressure ranges.
• Pressure range: 0.4 inHg to
103 inHg.
• Optional range: 3.4 inHg to
400 inHg
• Accuracy to ± 0.5 feet,
0.003 knots
• Extended mass set covers
entire air data range without
the need to change pistons
• Compatible with Autofloat
Controller and WinPrompt and
COMPASS software
Pressure
Calibration Systems
7250sys Multi-Range
Pressure Calibration System
Turn-key automated gas pressure
calibration system.
• Gas pressure measurement and
control from low absolute to
17 MPa (2500 psi)
• Fully integrated multi-range
pressure test and calibration
systems with a single interface
and single test port
• Select either an 8 range or the
12 range system for maximum
performance and coverage
Custom Pressure Calibration
Systems
Engineered custom systems integrate standard Fluke Calibration
products into a complete system
based on the user’s specific
requirements. These are often
multi-range systems that include
pressure generation and supply
accessories, data acquisition
hardware and software and/or
test instrument connection manifolds. Custom systems include but
are not limited to turn-key pressure calibration rack systems,
portable calibration carts and
automated pressure calibration
bench systems.
ADCS-601 Air Data
Calibration System
7250sys
36
Gas pressure calibration bench
system for absolute and differential measurement in the air data
range.
• Primary pressure calibration of
the entire air data range
• Fully automated, including test
execution, pressure control and
reference and device under test
data collection
Pressure Calibration
www.flukecal.com
Gas flow calibration
What is gas flow calibration?
Gas flow calibration refers to the calibration of a
flow sensing device such as a flow meter or flow
controller by comparing its measurement against a
flow measurement reference. Typically, the device,
or unit under test (UUT), is pneumatically connected in series with the flow reference so they
measure the same gas flow; then the indications of
the two devices are compared.
molbloc™/molbox™ system components
Fluke Calibration’s molbloc/molbox gas flow calibration system consists of molbloc flow elements
that connect to a flow terminal (either molbox1+ or
molbox RFM) so the terminal can use pressure and
temperature measurements from around the flow
element, combined with gas properties and prior
molbloc calibration data, to determine and display
the gas flow rate.
www.flukecal.com
Mass flow vs. volume flow
A frequent topic of discussion and confusion surrounding gas flow measurement is that of mass
flow versus volume flow. Flow meters and flow
units used for flow measurements are used to
measure and express either the amount of volume
of gas or the amount of mass (number of moles or
molecules) passing through the device. When performing a gas flow calibration, it is nearly always
beneficial to use a mass flow reference measurement, because the mass flow rate stays constant
throughout a flow system in steady state. Since
gas is compressible, the volume flow rate varies at
different locations in a flow system due to changes
in density caused by changing temperature and
pressure. molblocs are mass flow standards, which
allow reliable comparisons to other flow devices.
The molbox terminal is also able to calculate and
express the flow rate in terms of volume flow at
another point in the system to allow testing of
volume-based devices.
Gas Flow Calibration
37
molstic-L
molbox1+
molstic-S
molboc-L
molbloc-S
molbox RFM
Gas Flow Standards
molbox1+ Flow Terminal
0.125 % of reading—lowest uncertainty for gas flow calibration.
• Allows coverage of flow range
from less than 1 sccm to over
5000 slm with a single user
interface and transportable
system
• Real-time flow measurements
makes adjusting analog flow
devices fast and easy
• No moving parts that cause
pressure/flow fluctuations or
threaten reliability
• Perform fully-automated flow
calibrations using molbox terminal with COMPASS for Flow
software
• Updated design
molboc-L Laminar Flow
Element
Gas Flow Calibration
MFC Switchbox
molbloc-S Sonic Nozzle
Flow Element
Sonic nozzle based molblocs for
gas flow up to 5,000 slm.
• Covers ranges up to 5,000 slm
in N2 and air
• Multiple gases supported
• Useable with molbox1+, or
existing molbox1 and molbox
RFM mass flow terminals and
COMPASS software
• Proven critical flow venturi
(sonic) nozzle operating principle supported by primary
gravimetric calibration
molbox RFM Reference Flow
Monitor
Compact terminal for making mass
flow measurements using molbloc-L
and molbloc-S flow elements.
• Traceable to primary gravimetric mass flow measurements
• Economical alternative to
molbox1+ terminal
• ± 0.5 % of reading uncertainty
• Covers the flow range of 1 sccm
to 100 slm with molbloc-L, and
up to 5000 slm with molbloc-S
• 5141/5142/5144 kits feature
molbox RFM, molbloc-L and
other hardware for a complete
calibration system
molstic Mounting Systems
Used to conveniently mount and
protect molbloc elements, connect
to units under test and provide
Laminar flow elements for flow
flow and pressure control.
from 1 sccm to 100 slm.
• Traceable to primary gravimet- molstic-L used for molboc-L
mass flow elements.
ric mass flow measurements
• Quick connector input
• Multiple gases supported
• Useable with existing molbox1+ • 2 micron (0.5 micron for low
flow) filter to protect the
and molbox RFM mass flow terdownstream components
minals and COMPASS software
• Adjustable regulator protects
• Integrated filter to protect
the molbox transducers
against contamination
• Integral gas temperature condi- molstic-S used for molbloc-S
mass flow elements.
tioning and measurement
• Available in 1/2 inch or 1/4
inch system plumbing sizes
• Integrated flow shut-off/
metering valves
38
MFC-CB™
GFS™
Gas Flow Automation
Accessories
MFC-CB™ Control Box
Stand-alone unit for setting/
reading analog mass flow
controllers (MFCs) and mass
flow meters (MFMs).
• Set and read 0 to 5 V or 4 to
20 mA on two (2) channels
• Complete front panel local
control and remote operation
via RS-232 and IEEE-488
interfaces
MFC Switchbox™
Supplies power and switches
between up to five MFCs or
MFMs on one molbox1+ or
MFC-CB channel.
• Duplicates MFC channel
without switching cables
Primary Gas
Flow Standard
GFS Dynamic Gravimetric
Mass Flow Standard
True Primary Mass Flow Standard that makes the fundamental
measurement of low gas mass
flow rates practical.
• Covers the range of 0.2 to
200 mg/s in various gases
(10 sccm to 10 slm N2)
• Measurements can be transferred higher flow ranges using
Successive Addition method
• Flow measurement uncertainty
as low as ± 0.013 % of reading
www.flukecal.com
Calibration Software
“Calibration software” refers to applications that
automate all or part of a calibration process via
computer control. Calibration software also allows
users to manage their calibration and asset data.
If you’ve heard about the benefits of automated
calibration and asset management but are puzzled
about how everything fits together, call on Fluke
Calibration for solutions.
Other types of calibration software from
Fluke Calibration include data-logging software,
software that generates calibration constants
and references, and various add-on and plug-in
software programs.
Why use calibration software?
Using software to automate all or part of the
calibration process offers several important
advantages.
Efficiency—Automating the calibration process
allows technicians to set up tests and then go on
to perform other tasks, making more efficient use
of their time. Calibrations are typically completed
much more quickly, saving time and money. If the
software is capable of calibrating multiple units
under test simultaneously, automation increases
throughput as well.
Documentation and reports—Calibration automation software typically includes features for
documenting calibration procedures, storing calibration data, and producing reports, allowing users
to eliminate paper records or spreadsheets.
Because Fluke Calibration software does such a
good job of keeping accurate records of all parts of
the calibration process, it also supports compliance
with a wide variety of quality standards.
Consistency—Software automation ensures that
calibrations can be performed exactly the same
way by multiple operators in multiple locations.
This improves the quality of results, reduces errors
and standardizes methods.
www.flukecal.com
Calibration Software
39
Product highlights
40
MET/TEAM® Test Equipment Asset
Management Software
MET/CAL® Plus Calibration
Management Software
MET/TEAM® software is a powerful, flexible, and
scalable calibration management software solution
for managing your calibration assets. Designed by
metrologists for metrology, it is ideal for calibration professionals who need to manage workflow
through the calibration laboratory.
• Browser-based software enables access that is
convenient, yet secure
• Fully featured for tracking and managing assets
• Fully integrated with the Run Time function of
industry leading MET/CAL® software
• Replaces MET/TRACK as the recommended database engine for MET/CAL software
• Popular Microsoft SQL server database for reliable, affordable, non-proprietary data storage
• Workflow management
• Highly customizable fields and labels
• Shortcuts (quick links) for easy navigation
• Promotes quality processes to support
accreditation
• Customizable reports with Crystal Reports
Professional
• Automated email alerts and recall escalation
• Mobile module for on-site calibration
• Customer web portal to allow read-only access
for remote customers
• Commerce module for quoting, billing, and
contract pricing
• Designed for metrology by metrologists
• Backed by Fluke Calibration, expert in calibration instrumentation and software
• Collect and store manual calibration data
MET/CAL Plus software automates the calibration
process to help you manage your workload more
efficiently and consistently. The MET/CAL suite
of applications includes MET/CAL software, the
industry leader for automated calibration; plus
MET/TEAM software for asset management.
MET/CAL Plus software provides you with the
tools you need to:
• Perform automated calibration on all kinds of
test and measurement tools and equipment,
including dc/lf, RF and microwave instruments
• Create, edit, test, and document calibration
procedures, quickly and easily
• Configure and report a wider range of measurement uncertainty parameters and include
verification data to provide an audit trail and
support further analysis
• Track asset information including calibration
and maintenance history and status, traceability,
users, customers, and location
• Analyze and report asset information; produce
customized printed certificates and reports.
• Make data available to other corporate systems
• Import asset and calibration data into
MET/CAL Plus software
• Help meet the requirements of quality standards
like ISO 9000, ISO/IEC 17025, NRC 10 CFR, ANSI
Z540.3, and others
Calibration Software
www.flukecal.com
Warranted Procedures
for MET/CAL
MET/CAL®
Electrical/RF
Calibration
Software
MET/CAL®
The complete solution for automating calibration processes plus
managing and reporting measurement assets.
• Perform fast, repeatable, and
powerful calibration
• Full storage of calibration data
• Rich reporting capabilities
• Configure and report a wider
range of measurement uncertainty parameters
Warranted Procedures for
MET/CAL®
Fully tested, ready-to-go procedures designed to satisfy your
needs.
• Optional calibration procedures
for MET/CAL ® Plus Calibration
Software
• Warranted by Fluke Calibration
to produce valid calibrations
on the intended unit under test
(UUT) for the specified model
and revision level
• These procedures automate
the calibration process under
MET/CAL control
5080A/CAL
Easy-to-use standalone software
for the 5080A Multi-Product
Calibrator.
• Quickly calibrate a wide range
of analog and digital workload
• Provides automated control
of the calibrator; technician
simply enters readings from
the item being calibrated
• Easy-to-use procedure
designer; simply select the
type of signal needed to perform a test from a drop-down
menu, enter the test level and
set the test limits
www.flukecal.com
5080A/CAL
Software
Support
Programs
MET/SUPPORTSM Gold
MET/TEAM
Calibration Asset
Management
Software
MET/TEAM Test Equipment
Asset Management Software
Manage more workload with less
work with MET/TEAM software.
• Browser-based calibration
asset management software
• Fully integrated with MET/CAL®
Software
• Microsoft SQL Server database
• Highly customizable
• Email automation
• On-site calibration
• Work flow management
• Pricing/billing/invoicing
• Customer web portal
• Installation and training
services
Annual support programs for
MET/CAL and MET/TEAM software. These premier support
services help you maximize your
software investment.
• Premium support and services
to help you maximize productivity with MET/CAL and
MET/TEAM software
• Three levels of support let you
choose the services you need
– M ET/SUPPORT Gold: priority support, free access to
warranted procedures, free
software upgrades
– M ET/SUPPORT Procedures:
priority support, free access
to warranted procedures
– M ET/SUPPORT Upgrades: priority support, free software
upgrades
• Priority web content (all levels)
• Discounts on a variety of services (all levels)
MET/TEAM Software
Services
A range of services to help you
maximize your investment in
MET/TEAM software.
• MET/TEAM software installation and startup
• Standard MET/BASE-toMET/TEAM database migration
• Standard MET/TEAM database
import
• MET/TEAM self-validation
• Custom software services
Calibration Software
41
MET/TEMP II
LogWare
LogWare II
Temperature
Calibration Software
MET/TEMP II
LogWare III
Fully automated calibration of
RTDs, TCs, thermistors, and many
heat sources.
• Calibrates up to 100 sensors at
up to 40 points
• Performs coefficient calculations and generates tables and
reports
Remotely monitor and log a
virtually unlimited number of
concurrent log sessions into a
central data repository.
• Up to two temperature and two
humidity inputs for each DewK
• Customize your graph trace
color, alarms, and statistics as
you go
LogWare
Turn a Fluke Calibration singlechannel handheld or 1502A/1504
readout into a real-time data
logger.
• Collects real-time data
• Calculates statistics and displays customizable graphs
• Allows user-selected start
times, stop times and sample
intervals
LogWare II
Turn any Fluke Calibration multichannel thermometer readout
into a real-time data logger.
• Collects real-time data using
Fluke Calibration multi-channel
readouts
• Calculates statistics and displays customizable graphs
• Allows user-selected start
times, stop times and sample
intervals
42
Calibration Software
LogWare III
TableWare
Calculate-and-generate data
software package for manually
entered data.
• Generates temperature vs.
resistance, temperature vs.
ratio and temperature vs. EMF
tables
TableWare
• Calculates coefficients for RTDs,
thermistors and thermocouples
• Generates coefficients, calculates residual values and
generates useful tables
www.flukecal.com
Pressure/Flow
Calibration
Software
COMPASS® for Pressure
COMPASS for Pressure
Universal platform for automating
pressure calibration.
• Integrated piston gauge
support
• Runs complete automated
calibration sequences
• Supports multiple units under
test
• Automates virtually any
pressure standard or device
under test
COMPASS® for Flow
Macro-enabled mass flow calibration software package.
• Fully customizable
• Supports non Fluke Calibration
flow references
• Performs complex real time
flow computations, and allows
you to alter test scenarios
based on data collected
COMPASS for Flow
COMPASS for Pressure
www.flukecal.com
Calibration Software
43
Data acquisition and
general purpose test equipment
Data acquisition equipment
Get the data you want, where, how and when you
want it. Fluke gives you a broad choice in data
acquisition for process monitoring and laboratory
test systems. You can choose a stationary or portable data logger. Transfer data to internal memory,
to a removable memory card, or to your PC. Choose
a standalone or distributed networked units. And
you can expand your system from 20 to 1,000+
channels, depending on the series.
All Fluke data acquisition products feature
unique, built-in universal signal conditioning and
a plug-in Universal Input Module to enable you
to measure virtually any type of signal without
having to purchase extra equipment. Plus, powerful, easy-to-use Windows®-based software
supports easy configuration, advanced trend analysis, professional- quality reporting, and enables
you to quickly build human-machine-interfaces
without any programming.
44
Data Acquisition
General purpose test equipment
Fluke Calibration designs and manufactures
bench instruments in a wide variety of product categories. Besides their use on the bench,
these instruments have several characteristics in common as you will find below:
• Each bench instrument is accurate and provides
precise information. They reflect the professionalism of the people who buy and use them.
• Each is reliable, dependable, and rugged.
• All are easy to operate. Many owners of Fluke
bench instruments say that the controls are
intuitive and help them work more efficiently.
• These bench instruments are compact and easily
transported, but they are also multi-functional.
• You will find that these instruments are a good
value, particularly when compared against other
tools for their cost/function ratio.
www.flukecal.com
Product highlights
2638A Hydra Series III Data Acquisition System
A price performance breakthrough in standalone
data acquisition system
The Fluke Hydra Series III continues the Hydra series legacy in data acquisition.
This new Hydra series improves on the long standing, industry leading specification of best-in-class thermocouple accuracy. With basic dc measurement accuracy
of 0.0024 %, 0.5 °C thermocouple accuracy, color trend display, easy-to-use menu
system and world-class industrial safety ratings, the 2638A is a truly industrial
grade, precision data acquisition system.
Expandable from 22 to 66 channels of analog differential measurement, the
Hydra 2638A offers the flexibility of our Universal Input Connector, which allows
quick connect and disconnect of any type of input to any channel. AC and dc voltage, resistance, thermocouple, RTD, thermistor, frequency and dc and ac current are
all selectable inputs for the 2638A. If your measurement need is from under twenty
channels to over sixty-six channels per unit or thousands of channels per system,
we have you covered.
• DC accuracy of 0.0024 %
• Best-in-class thermocouple accuracy of 0.5 °C
• Up to 67 universal differential, isolated inputs
• On-screen color trend graphing
• Easy menu system for setup and data management
• Multi-channel real-time data display
• 6.5 digit DMM function selections
• Monitor function for real-time viewing and charting between scans
• 20 on-board separate math channels
• 45 channels/sec basic dc scan rate
• Internal 75,000 scan memory plus USB drive port
• Data security features
• CAT II 300 V input safety rated
www.flukecal.com
Data Acquisition
45
2638A
2686A
NetDAQ (2640)
Data Acquisition Equipment
46
2638A Hydra Series III Data
Acquisition System/DMM
2680 Series Data
Acquisition Systems
NetDAQ® Networked Data
Acquisition Unit
A price performance breakthrough in standalone data
acquisition system.
• DC accuracy of 0.0024 %
• Best in class thermocouple
accuracy of 0.5 °C
• Up to 67 universal differential,
isolated inputs
• On screen color trend graphing
• Easy menu system for setup
and data management
• 6.5 digit DMM function
selections
• Monitor function for realtime viewing and charting
between scans
• 20 on-board separate math
channels
• 45 channels/sec basic dc
scan rate
• Internal 75,000 scan memory
plus USB drive port
• Expands to thousands of channels with application software
• Data security features
• USB flash drive support for
data transfer to PC
• CAT II 300 V input safety rated
Standalone or networked
precision multi-channel data
acquisition
• 20 to 120 universal analog
inputs per chassis; systems to
+2,000 channels
• Stand-alone data logger operation with the 2686A
• Large scalable LAN systems using the 2680A with
10BaseT/100BaseT
• Two types of Universal Input
Modules: high-isolation precision modules or fast scan
modules, with 16- to 18-bit
resolution
• Throughput of more than
3,000 channels-per-secondper-chassis with 2680A-FAI
modules
• Superior thermocouple measurement accuracy (J, K, R, S,
T, N, I, U, C, B)
• 20 digital I/O and 8 form C, 1
Amp relay output modules for
direct control of equipment
• Up to 300 V input isolation,
1600 V transient overvoltage
protection (2680A-PAI)
• Universal input conditioning for
any input, on any channel, in
any combination (V dc, V ac,
Ohms, frequency, RTD, thermocouple, thermistor or current
• ATA flash memory card for
stand-alone operation - from
16 MB to 1 GB (2686A only)
• Multiple power sources: 100 V
to 240 V and 9 V to 45 V dc
• Includes Fluke DAQ Software:
Controls all 2680 Series functions, provides real-time and
historical and also communicates with NetDAQ and Hydra
Series III products
Powerful combination of hardware and software that is ideal
for small-to-medium scale process monitoring and test systems.
• Data acquisition, up to 1,000
readings per second
• 20 analog input channels
expandable up to 2,000
channels
• Extensive optional plotting and
trending capabilities
• Includes Fluke DAQ software
• Flexible ac or dc power
• Replaces chart recorders
Data Acquisition
www.flukecal.com
8845A/8846A
80/81
397
8808A
271
General Purpose Test Equipment
290
280
8845A/8846A 6.5 Digit
Precision Multimeters
80/81 Function Pulse
Generators
290 Series Waveform
Generators
Precision and versatility for
bench or systems applications.
• 6.5 digit resolution
• Basic V dc accuracy of up to
0.0024 %
• Dual display
• 100 μA to 10 A current range,
with up to 100 pA resolution
• Wide ohms range from 10 Ω
to 1 GΩ with up to 10 μΩ
resolution
• 2 x 4 ohms 4-wire measurement technique
• Both models measure
frequency and period
• 8846A also measures capacitance and temperature
• USB memory drive port
(8846A)
• Fluke 45 and Agilent 34401A
emulation
• Graphical display
• Trendplot™ paperless recorder
mode, statistics, histogram
• CAT I 1000 V, CAT II 600 V
• Three-year warranty
50 MHz function/pulse generators, ideal for both benchtop and
ATE applications.
• Model 81 pulse/function
generator
• Model 80 function generator
• Powerful performance
• AM, FM, VCO, and phaselock/
offset control modes
• Automated calibration
• Ideal for both benchtop and
ATE applications
• HP 8116A emulation mode
(81 only)
One, two, or four channel
100 MS/s waveform generators.
• 100 MS/s 12-bit arbitrary
waveform capability
• 1 M point waveform memory
• 40 MHz function generator
capabilities using DDS (50 MHz
for square waves)
• 10 ns pulse pattern generator
• Waveform sequencing with up
to 1024 segments
• Unlimited waveform storage
using CF® memory card
• Waveform Manager Plus for
Windows software
• USB interface in addition to
RS-232 and GPIB
8808A Digital Multimeter
Versatile multimeter for manufacturing, development and service
applications.
• 5.5 digit resolution
• Basic V dc accuracy of 0.015 %
• Dual display
• Dedicated dc leakage current
measurement
• 2x4 ohms 4-wire measurement
technique
• Six dedicated buttons for fast
access to instrument setups
• Hi/Lo limit compare for Pass/
Fail testing
• Three-year warranty
www.flukecal.com
271 DDS Function Generator
with ARB
High performance function
generator.
• High stability 10 MHz DDS
function generator
• Arbitrary capability with
storage for five user defined
waveforms
• Multiple standard and complex
waveforms recalled from internal memory
• Extensive modulation capabilities include sweep, AM, Gating,
Trigger/Burst, FSK and Hop
• GPIB and RS-232 interfaces
397 Universal Waveform
Generator
125 MS/s high performance universal waveform generators.
• Unprecedented combination
of universal generator and
synthesizer
• Versatile performance
• High resolution and wide
frequency range
• Extremely good performanceto-price ratio
280 Series Waveform
Generators
Universal waveform generators
offering superior performance
and value.
• Choice of 1, 2 and 4 independent or linked channels
• 40 MS/s max. sampling speed
• 16 MHz function generator
• 10 MHz pulse generator
• Pulse train pattern generator
• Arbitrary waveforms of up to
65 k points
• Powerful modulation
capabilities
• Built-in trigger generators
• Waveform Manager Plus for
Windows® software
• Multiple standard waveforms
recalled from internal memory
• RS-232 and GPIB interfaces
Data Acquisition
47
Service programs
Instrument CarePlan
Instrument CarePlan
Fluke Priority Gold CarePlan
Silver CarePlan
The Fluke Priority Gold CarePlan is a comprehensive
instrument calibration and repair support plan that
minimizes your downtime and protects your investment in your Fluke calibrators. It’s the “good as
gold” priority customer service program that gives
you all these extra privileges:
• Annual calibration included (standard or accredited) with guaranteed three-day in-house
turnaround1,2 for electrical calibrators and six-day
guarantee for pressure and temperature products
• Free repairs with guaranteed ten-day in-house
repair (includes calibration)2,3
• Pre-paid, priority freight on return of instrument
• Free product updates
• One-year, three-year and five-year plans
available
• 10 % off on calibration product upgrades
• 20 % off any scheduled Fluke Calibration
metrology training for any of your personnel
• Automatic 45-day and 15-day calibration due
notification
• Free transit case for your instruments (Europe)
The Fluke Silver CarePlan is a comprehensive
instrument warranty support plan that puts you
in charge of your operating costs and protects
your investment in your new Fluke Calibration
instrument.
• Extended warranty coverage for your instrument
• Calibration included on repairs covered by your
plan
• 15 % discount on regular calibrations during your
factory and Silver CarePlan term
• 15 % discount on any out-of-plan service changes
• Free product updates (PCNs) performed at the time
of repair
• One, two, three, four and five-year plans
available
48
Service and training
1. Guaranteed in-house turnaround not available in all countries; contact your local Fluke
representative for details. Priority shipping times vary by country.
2. One-year and three-year Priority Gold CarePlans do not cover instrument repairs in the
first 60 days and 30 days respectively after plan purchase. Five-year plans are eligible for
immediate repair services covered under the program.
3. Instruments showing signs of failure due to physical abuse, improper operation or
application do not qualify for free repair and will be repaired at 15 % discount from
standard repair rates.
www.flukecal.com
Self-paced training tools
Register your Fluke
Calibration product online
Instructor-led web-based
training
Our instructor-led web-based
trainings offer the same great
access to Fluke Calibration
experts, with the added benefit
Authorized Fluke Calibration of not having to travel. Instructor-led web-based trainings are
Service Centers
Fluke Calibration offers calibration designed to fit into your schedule, without disrupting your
and repair services and support
workflow. Courses are set up in
through our flagship metrology
laboratories and service partners anywhere from one to five parts,
worldwide. To find the best solu- two hours each, held on consecutive days.
tion for your calibration product
you can visit www.flukecal.
Self-paced online training
com/service-centers, call us at
877-355-3225, or email us at
Our self-paced calibration and
service@flukecal.com.
metrology training courses were
developed by Fluke Calibration
and other technical experts in
Training
Calibration and metrology training the metrology community using
proven instructional design
from Fluke Calibration can help
components. At the start of each
you and your staff become more
module, a brief tutorial describes
knowledgeable in a wide variety of disciplines. Instructors are how the course is laid out. The
learning objectives are clearly
experts who work in electrical,
stated. Topics are selected from
temperature, pressure and flow
calibration, and who really want easy-to-navigate menus and
sub-menus. Embedded questo help you learn the foundation
and techniques of metrology that tions are presented frequently
to increase retention. Engaging
you can put to immediate use in
your workplace. Fluke Calibration graphics, photos, formulas and
tables support text material. A
offers introductory, intermediate,
final post-test provides proof of
and advanced level courses in a
competency. Tests are shuffled
variety of formats to meet your
after each use. Most importantly,
needs.
a certificate of completion satisfies documentation requirements.
Instructor-led classroom
Visit www.flukecal.com/
register-product to register your
product today!
courses
Our instructor-led courses cover
a variety of metrology topics and
range from one to five days in
length. Held in various locations
around the world, training from
Fluke Calibration is a great way to
maximize your investment in your
calibration equipment.
www.flukecal.com
In addition to self-paced online
training, Fluke Calibration offers
several additional self-paced
training tools for metrology
software and dc/low frequency
metrology. Our self-paced metrology software CD-ROMs give you
the ability to learn at your own
pace. The familiar web interface
makes navigating this program easy, and upon successful
completion of the course you will
be provided with a completion
certificate. Fluke Calibration also
offers the only comprehensive text
book on dc/low frequency metrology, Calibration: Philosophy in
Practice, Second Edition. It covers
real world concepts and applications, and is designed and written
for the working technician.
On-site training
Fluke Calibration instructor-led
courses may also be taught at
your facility. If you have a large
number of students, or if the
material you wish to discuss
is considered confidential, you
may find On-Site Training an
attractive alternative. Contact
your local Fluke Calibration
representative to discuss specific
requirements and arrangements,
or email training@flukecal.com
for a Fluke Calibration representative to contact you.
For an up-to-date course
schedules, and pricing, and
training resources visit:
www.flukecal.com/training
Installation and training
supplemental services
Fluke Calibration offers expert
consulting to help you configure
and use your calibration products
as productively and cost-effectively as possible. We can help:
• Minimize downtime
• Make sure your equipment
runs efficiently
• Confirm that systems are operating properly
• Train you and/or your staff at
your site, a separate site, at
Fluke Calibration or online
Service and training
49
Fluke Calibration. Precision, performance, confidence.™
Fluke Calibration
PO Box 9090,
Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
Web access: http://www.flukecal.eu
For more information call:
In the U.S.A. (877) 355-3225 or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116
Web access: http://www.flukecal.com
©2011-2014 Fluke Calibration. Specifications subject to change without notice.
Printed in U.S.A. 4/2014 4026225D_EN Pub-ID: 12124-eng
Modification of this document is not permitted without written permission
from Fluke Calibration.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising