User Manual - Samsung Techwin UK

User Manual

Passive-Infrared Sensor (Dome)

SIP-0012DA

Important Safety Instructions

1.

2.

Read these instructions.

Keep these instructions.

3.

Heed all warnings.

4.

5.

Follow all instructions.

Do not use this apparatus near water.

6.

Clean only with dry cloth.

7.

Do not block any ventilation openings, Install in accordance with the manufacturer’s instructions.

8.

Do not install near any heat sources such as radiators, heat reaisters, stoves, or other apparatus (including amplifi ers) that produce heat.

9.

Do not defeat the safety purpose of the polarized or grounding-type plug, A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety, If the provided plug does not fi t into your outlet, consult an electrician for replacement of the obsolete outlet.

10.

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.

Only use attachments/ accessories specifi ed by the manufacturer.

English

_1

12.

Use only with the cart, stand, tripod, bracket, or table specifi ed by the manufacturer, or sold with the apparatus. When a cart is used. Use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13.

Unplug this apparatus during lighting storms or when unused for long periods of time.

14.

Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO

NOT EXPOSE THIS PROCUCT TO RAIN OR MOISTURE.

DO NOT INSERT ANY METALLIC OBJECT THROUGH THE

VENTILATION GRILLS OR OTHER OPENNINGS ON THE

EQUIPMENT.

Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus

CAUTION

CAUTION

RISK OF ELECTRIC SHOCK.

DO NOT OPEN

CAUTION

: TO REDUCE THE RISK OF ELECTRIC SHOCK.

DO NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

English

_2

EXPLANATION OF GRAPHICAL SYMBOLS

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

Class construction

An apparatus with CLASS construction shall be connected to a

MAINS socket outlet with a protective earthing connection.

Battery

Batteries(battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or the like.

Disconnection Device

Disconnect the main plug from the apparatus, if it’s defected.

And please call a repair man in your location.

When used outside of the U.S., it may be used HAR code with fittings of an approved agency is employed.

CAUTION

These servicing instructions are for use by qualified service personnel only.

To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

English

_3

Please read the following recommend safety precautions carefully.

y

Do not Place this apparatus on an uneven surface.

y

Do not install on a surface where it is exposed to direct sunlight, near heating equipment or heavy cold area.

y

Do not place this apparatus near.

y

Do not attempt to service this apparatus yourself.

y

Do not place a glass of water on the product.

y

Do not install near any magnetic sources.

y

Do not block any ventilation openings.

y

Do not place heavy items on the product.

User’s Manual is a guidance book how to use the products

The meaning of the using sign in the book is following y

Reference: in case of providing information for helping of product’s usages y

Notice: If there’s any possibility to occur any damages for the goods and human caused by not following the instruction

Ú Please read this manual for the safety before using of goods and keep it in the safe place.

English

_4

IR Sensor at a Glance

Cover Body

Alarm LED

LENS

Fixing Holes

LENS

DIP Switch

Wiring Hole

What’s Included

Terminal

Screw (x2)

User Manual/

Warranty Card

English

_5

Installation

1.

Turn the cover left to loosen it from the body.

2.

Pull out the cables from the ceiling and use the screws to fi x the body on the ceiling.

3.

Adjust the lens in full detail to set the boundary scanning range.

4.

Turn the cover right to close it.

English

_6

Terminal Layout

Terminal Indication

POWER DC+12V Input

ALARM

TAMPER

Normal Close/Normal Open

Tamper Output

Jumper Pin Setting

By the factory default, the jumpers are set as follows:

COUNT = 2 times

SENS = LOW

LED = ON

MEMORY = OFF

ON

OFF

1

COUNT

4

2

2

SENS

HIGH

LOW

3

LED

ON

OFF

Description

Nonpolar

4

MEMORY

ON

OFF

M

 Precaution for the count setting: you must set the count to 2 times if you want to use the sensor for the spatial scanning.

Setting

Factory Default

OUTPUT

Scanning:

Connected

Alarming:

Disconnected

Scanning:

Disconnected

Alarming:

Connected

English

_7

Checking the boundary scanning range

Ceiling Mount Wall Mount

Height: 2.6m

85° cubic scanning

Width: 1.5m

spatial scanning

12 m

Height: 2.6m

85° cubic scanning

Width: 1.5m

spatial scanning

8 m

English

_8

Specifi cations & Appearance

Specifi cations

Item

Scanning Type

Scanning Range

Input Voltage

Current Consumption

Number of Sensing Zones

Height

Sensing Speed

Alarm Output Point of Contact Capacity

Alarm Operating Time

LED Status

Temperature

Dimension

Weight

Description

Cubic Scanning max. 12 m, angle: 84°

DC 12V (±15%)

17mA (max)

15 zones

1.8m ~ 3.0m (basis of 2.6m) min. 0.2m/s, max. 1.5 m/s

1 A (30V)

Less than 2 seconds

LED lights up when an alarm occurs

(turns off automatically after that)

-10˚C ~ 50˚C (humidity 95%)

ø132 X height 52mm

Approx. 90g

Appearance

Unit: mm

132

132

English

_9

Correct Disposal of This Product

(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling.

Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.

P/No. : Z6806120501A-00

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement