TCD-41K Operation Explanation n Explanation of Panel nCurrent Value CONCH ■ Set1 Setting Value counter/timer Input Indication Lamp Timer Mode, Parameter Value Setup (TIMER MODE) (Press “MODE” key to start, turn SW-1 to OFF and SW-4 to ON) Output Time:(tr) Indication Lamp of Timing unit s m h cnt out Output Indication Lamp mode RST MODE Key mode 4 Disp Key Timer Mode Setup :(Timer mode) RST disp 3 Setting the output hold time of RELAY Range:0.01 to 9.99 seconds, please press number key 1,2,3 to setup. 2 Setting the counter to count up, and down. Please press “1” key for option. 1 Number Key 1~4 mode 1 Name of Key Function Enter input setting mode, and swift to parameter Setup. Finish setting, and back to counting mode. Mode Disp Number Key1~4 RST n CP1 touch to count up CP2 stop timing Timer Unit Setup: Setting the min. timing unit of timer, please press “1” for setup. Used to change parameter value. 99.99 sec. Display value, RELAY return. mode Specification Power Supply Power Consumption Input Frequency AC 100V~240V, 60/50Hz ±10% Max. 8VA 25 Hz,2kHz(by SW-5 switch for option) Inputs ON Impedance 2kΩ max. NPN(Non-Voltage) OFF Impedance 100kΩ min. RELAY Contact Output Ambient Temperature Storage Temperature Relative Humidity Contact: 5A,240VAC,resistance load(p.f=1). 0 to 55℃ with no icing -25 to 65℃ with no icing 35% to 85% RH ■ 999.9 sec. s m h 1 s m h 1 s m h s m h 1 s m h 1 999.9 min. 99 hour 59 min. 1 s m h 999.9 hour Power-on RESET: Current value return when setting power input. Press ”1” key for setup. mode (Press “MODE” key to start, turn SW-1、SW-4 to OFF) 1 Memory of current value Output Time:(tr) Setting the output hold time of RELAY Range:0.01 to 9.99 seconds, please press number key 1,2,3 to setup. 1 Current value return disp Finish Setting Counting Scale: (SCALE): The parameter can change the input signal to actual physical capacity(volume, and length). For example: Per pulse of input signal is 0.1mm, and setting the counting scale to 0.1, the range: 0.001 ~ 9.999. Please 1 to 4 to change your counting scale. mode 9999 sec. s m h 99 min. 59 sec. Counter Mode, Parameter Value Setup mode 1 CP1 touch to count Down CP2 stop timing n ON Explanation of Setting Switch(Located at the rear of panel) Parameter Protection (KEY/PRO): 1 2 3 4 5 If turn SW-1 to ON, the “mode” key of panel can’t work. Then, it is able to modify the protection parameter value. Decimal point: Setting the decimal point positing of current value. Please press 1,2,3,4 to setup. mode RELAY Output Mode Adjustable Counter Mode Setup: ON 1 2 3 4 5 Setting the counting up, down and single phase addition & subtraction of counter. Please press “1” for setup. mode N position: Present Value ≧SET1 Setting Value, RELAY keep output,press RST key to return. ON 1 2 3 4 5 1 CP1 counting up CP2 stop counting 1 CP1 counting down CP2 stop counting R position: Current Value ≧SET1 Setting Value. RELAY output and return with current value after delaying tr time. 1 CP1 counting up CP2 counting down Power-on RESET: Current value return when setting power input. Press ”1” key for setup ON 1 2 3 4 5 ON 1 2 3 4 5 mode 1 Memory of current value 1 ON 1 2 3 4 5 Current value return C position: Current Value ≧ SET1 Setting Value, RELAY output, current value delay to return immediately. RELAY return after tr time。 D position: Current Value ≧ SET1 Setting Value,,RELAY keep Output, stop counting/timing and press RST key to return. Counter/Timer Mode: Turn SW-4 to OFF is counter mode, and the cnt lamp of panel will light. If in ON position, which is timer mode. disp Finishing Setting ON 1 2 3 4 5 Input Frequency Limited: Turn SW-5 to OFF(HI), the max. input signal is 2KHz. And, at ON(LO),is 20Hz. TCD-41K Operation Explanation n ★Noted: Except SW-1, it must to turn on the meter again when modify the setting. n Display N position CV CV UP COUNT SET1 DOWN COUNT SET1 T T CP2 RS OUT R position CV CV UP COUNT SET1 DOWN COUNT SET1 T T CP2 RS OUT tr tr tr tr C position CV CV UP COUNT SET1 DOWN COUNT SET1 T T CP2 RS OUT tr tr tr tr D position CV CV UP COUNT SET1 DOWN COUNT SET1 T T CP2 RS OUT n Terminal Connector 0V 6 RS CP2 CP1 7 8 9 11 1 on 1 2 3 4 5 2 3 10 12 4 5 Dimension Diagram
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement