HUBER+SUHNER SENCITY Link SL60-3001, SL60-4001 wireless link Installation and User Manual
SENCITY Link SL60-3001, SENCITY Link SL60-4001 are wireless link operating in the unlicensed 60 GHz band between 57 GHz and 64 GHz and delivers a full duplex data rate of 100 Mbps over a distance of up to 800 m (2600 ft).
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Installation and User Manual
SENCITY
®
Link SL60-3001/SL60-4001
Revision F
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
We, HUBER+SUHNER AG of Degersheimerstrasse 14, CH-9100 Herisau/Switzerland declare that the product
SENCITY®Link / SL60-3001, SL60-4001 (formerly: SL60-100-57/64-38-E-O) is in conformity – after consultation with the notified body Phoenix Testlab (No. 0700) – with the following standards and normative documents:
●
●
EN 50371 (2002): Generic standard to demonstrate the compliance of low power electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (10 MHz - 300 GHz)
EN 55022 (2006): Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
●
●
EN 55024 (1998): Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN 60950-1 (2006): Information technology equipment - Safety -- Part 1: General requirements
●
●
●
ETSI EN 302 217-3 (2007): Fixed Radio Systems; Characteristics and requirements for point-topoint equipment and antennas; Part 3: Harmonized EN covering essential requirements of Article
3.2 of R&TTE Directive for equipment operating in frequency bands where simplified or no frequency co-ordination procedures are applied
ETSI EN 302 217-4-2 (2007): Fixed Radio Systems; Characteristics and requirements for pointto-point equipment and antennas; Part 4-2: Harmonized EN covering essential requirements of
Article 3.2 of R&TTE Directive for antennas is in accordance with the following Directives:
R&TTE Directive 1999/5/EC
We hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications. The unit complies with all essential requirements of the Directives.
Herisau, January 2008
© 2010 HUBER+SUHNER AG 3
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
If this product is suspected of causing harmful interference with other equipment, discontinue its operation immediately and contact HUBER+SUHNER.
In order to meet FCC RF Exposure requirements, this device must be installed in such a way that a distance of 2 m is always maintained between the device antenna and nearby persons.
Modifications or substitutions made on the terminal or parts of it without the written approval of
HUBER+SUHNER could void the user’s authority to operate the equipment.
FCC ID: TTDSL60100
IC: 6318A-SL60100
4 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
TABLE OF CONTENTS
1 Introduction
1.1 Intended users
1.2 Revision
1.3 Prior knowledge
1.4 Organisation
1.5 Used symbols
1.6 Safety
1.7 Warranty
1.8 Copyright / Disclaimer
2 System overview
2.1 General description
2.1.1 Benefits
2.1.2 Applications
2.2 System components
2.2.1 Terminals
2.2.2 Alignment bracket
2.2.3 Alignment tool
2.2.4 Ice bridge
2.2.5 Sealed Ethernet connector
2.2.6 Accessories
2.2.6.1 PoE injector (accessory)
16
16
2.2.6.2 Data line protector (accessory) 16
2.2.6.3 Mast bracket (accessory)
2.2.6.4 Ethernet cables (accessory)
3 Site planning
17
17
18
3.1 Terminal location
3.2 Line of sight
3.3 Link distance / Link availability
3.4 Terminal mounting options
19
20
20
21
13
13
14
12
12
12
14
15
15
15
7
7
8
7
7
9
10
10
11
3.4.1 Wall mounting
3.4.2 Pole mounting
3.5 Cabling
3.6 Grounding / Lightning protection
3.7 Co-located applications
4 Installation
4.1 Unpacking
4.2 Mount installation
4.2.1 Wall mount
4.2.2 Mast mount
4.3 Terminal installation
4.4 Cable installation
4.5 Antenna alignment
4.5.1 Alignment Procedure
4.5.1.1 Optical alignment
4.5.1.2 Power level alignment
4.6 Grounding
4.7 Lightning / Surge protector
4.8 Power injector
5 Terminal management and monitoring functions 32
5.1 Web browser interface 33
5.1.1 System overview screen 33
5.1.1.1 Traffic light colors
5.1.2 Password screen
5.1.3 Firmware update screen
33
33
34
5.1.4 Network configuration screen
5.1.5 Radio alignment screen
5.1.6 Network statistics screen
5.1.7 SNMP configuration screen
34
35
35
36
28
29
29
26
27
27
30
30
31
31
21
21
22
22
23
24
24
25
25
© 2010 HUBER+SUHNER AG 5
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5.2 SNMP interface
5.3 Reset-CD
5.3.1 Parameter reset
5.3.2 Firmware upload
A Technical information
A.1 Troubleshooting
A.1.1 Power and network connection
A.1.2 Network configuration
A.1.3 Duplex mismatch
A.1.4 Miss-alignment
A.2 Specifications
A.2.1 Ethernet cable colour code
A.3 Receiver level / Rain / Link distance
A.4 Availability / Rain zone / Link distance
A.4.1 Map of America
42
42
44
41
41
41
47
48
49
49
37
39
40
40
41
A.4.2 Map of Asia and Middle East
A.4.3 Map of Europe
A.5 Accessories order information
B Country specific information
B.1.1 Switzerland, Germany
B.1.1.1 English
B.1.1.2 Deutsch
B.1.1.3 Français
B.1.1.4 Italiano
C Contacts
C.1.1 Technical assistance
C.1.2 Service center / RMA
D Glossary
E Notes
59
60
60
58
58
59
60
61
62
51
53
55
58
58
6 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
1 INTRODUCTION
1.1 I
NTENDED USERS
This manual is intended for all installation and service personnel who are involved in the planning, installation, operation and maintenance of SL60-3001 / SL60-4001 equipment.
Please read the complete SL60-3001 / SL60-4001 (SENCITY®Link) manual prior to its unpacking, installation, setup and deployment.
Although the SENCITY®Link is designed for easy installation and setup, optimum performance can be achieved by following the procedures outlined in this manual.
1.2 R
EVISION
HUBER+SUHNER reserves the right to revise this documentation periodically without any obligation to provide notification of such revision or changes. The latest revision can be downloaded on http://www.sl60.com.
1.3 P
RIOR KNOWLEDGE
This manual assumes that the installer has at least a basic experience and understanding of networking equipment, as well as some familiarity with its configuration and operation. The information covered in this manual should be fully understood prior to installation.
© 2010 HUBER+SUHNER AG 7
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
1.4 O
RGANISATION
This user manual is organised into chapters as follows:
● Chapter 1: Introduction – Describes general and legal information.
●
●
Chapter 2: System Overview – Contains the technical data and the description of the equipments.
Chapter 3: Site Planning – Summarizes the requirements regarding site and network. This chapter has to be read as preparation for the installation.
Chapter 4: Installation – Describes the recommended installation procedure of the terminal.
●
●
●
Chapter 5: Management and monitoring functions
Appendix A: Presents additional useful technical information like: troubleshooting, weather maps and technical data.
Appendix B: Country specific information ●
●
●
Appendix C: Contacts
Appendix D: Glossary – Helps with the most important abbreviations.
8 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
1.5 U
SED SYMBOLS
Danger
Not used
Warning
Risk for human and equipment
Caution
Risk for equipment and functionality
Advice
© 2010 HUBER+SUHNER AG 9
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
1.6 S
AFETY
The following general safety precautions must be observed during all phases of operation and service of those products covered in this manual. Failure to comply with these precautions, or with specific warnings elsewhere in this manual, willfully violates standards of design, manufacture and the intended use of the product.
The SL60-3001 / SL60-4001 meets all CE and FCC electrometric radiation safety requirements for radio equipment. However, it is advisable to avoid long-term exposure to the front face of the terminal while operating this equipment.
Outdoor equipment must be properly grounded to provide some protection
against voltage surges and built-up static charges (as illustrated in chapters 4.6
All electrical and mechanical installations must comply with local and/or national electrical and building codes.
This equipment must not be modified. Neither must any of its component parts be substituted.
1.7 W
ARRANTY
HUBER+SUHNER warrants to the original end user (purchaser) that this product is free from any defects in materials or workmanship for a period of up to one year from the date of shipment to the end user.
During the warranty period, and upon proof of purchase, should the product show indications of failure due to faulty workmanship and/or materials, HUBER+SUHNER will, at its discretion, repair or replace the defective products or components without charge for either parts or labor, and to whatever extent it shall deem
10 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
necessary to restore the product or components to full operating condition. Any replacement will consist of a new or remanufactured, functionally equivalent product of equal value, and will be offered solely at the discretion of HUBER+SUHNER.
This warranty shall not apply if the product is modified (e.g. warranty seal is broken), misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions.
To obtain services under this warranty, contact HUBER+SUHNER‘s Service Center, referring to your Return
that the terminal be insured when shipped. Any products returned without either proof of purchase or with an outdated warranty will be repaired or replaced and the customer will be billed for parts and labor. All repaired or replaced products will be shipped by HUBER+SUHNER to the corresponding return address ‘Postage
Paid’ (USA only). If the customer specifies some other return destination beyond US borders, the customer shall bear the cost of the return shipment. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
1.8 C
OPYRIGHT
/ D
ISCLAIMER
Copyright © 2010 by HUBER+SUHNER
The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, translated into any language, or transmitted in any form or by any means, electronic, mechanical, magnetic, optical, chemical, photocopying, manual, or otherwise, without the prior written permission of HUBER+SUHNER.
© 2010 HUBER+SUHNER AG 11
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
2 SYSTEM OVERVIEW
2.1 G
ENERAL DESCRIPTION
The SL60-3001 / SL60-4001 system operates as a data link in the unlicensed 60 GHz band between 57 GHz and 64 GHz and delivers a full duplex data rate of 100 Mbps over a distance of up to 800 m (2600 ft).
Measuring only 16 cm × 16 cm (6.3“ × 6.3“), the terminal’s compact size is attained by extensively integrating the active and passive components.
For more detailed technical data see appendix A.2.
2.1.1 Benefits
●
●
Easy installation – The concept of the
SENCITY®Link allows to the end user to install it as easy as any other network component.
The single cable solution reduces the complexity of the installation. The terminal is connected to the network, monitored and supplied with power through a single outdoor rated CAT 5e Ethernet cable.
The visual alignment tool and an alignment bracket allows the user to easily install the link.
Immediate operation without the need of additional configuration is granted.
Network performance – Guaranteed full duplex 100 Mbps along the complete range. Unlike typical
WLAN equipment the user can transmit a full 100 Mbps over the link.
12 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
●
●
●
License free operation – The system has been approved and can be operated in many countries.
System administration – To monitor the status and the traffic the user can access the link statistics either via the HTML user interface or by integrating it into a network management tool via SNMP.
Security – The proprietary radio interface does not allow any other system to access the 60 GHz transmitted data.
A high level of data security is inherent in the product via signal absorption by atmospheric oxygen and the use of high gain/narrow beam width antennas.
2.1.2 Applications
●
●
●
●
●
●
●
●
LAN extension
Redundant access
Campus connectivity
Disaster recovery
Wireless backhaul
Centralization of IT infrastructure
Temporary connections during events
Mesh and hub and spoke configuration
2.2 S
YSTEM COMPONENTS
The SL60-3001 / SL60-4001 system is composed of the following components:
● Terminal A and Terminal B
●
●
●
Alignment bracket
Alignment tool
Ice bridge
© 2010 HUBER+SUHNER AG 13
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
●
●
Sealed Ethernet connection
○
○
○
Main accessories:
○
PoE injector
Lightning protector
Mast bracket
Ethernet cables
2.2.1 Terminals
The terminals are the main system components. They combine the antenna, transmitter and receiver and are connected to the network via a standard
Ethernet cable with RJ-45 connector.
Power is supplied through the Ethernet cable to the terminal. This will require either a PoE (802.3af) compatible network equipment or an additional PoE injector.
2.2.2 Alignment bracket
The alignment bracket facilitates installation and positioning owing to its independent axis with coarse and fine alignment capabilities.
14 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
2.2.3 Alignment tool
The optical alignment tool provided is easily mounted on the terminal using an elastic band. It enables both ends of the link to be aligned quickly, simply and independently.
2.2.4 Ice bridge
The ice bridge offers an additional protection for the terminal against rain, snow and ice-formation.
2.2.5 Sealed Ethernet connector
The seal kit is used to make a watertight connection of the Ethernet coupling. Please use the separate instructions for a proper installation of the seal kit.
© 2010 HUBER+SUHNER AG 15
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
2.2.6 Accessories
Please also refer to section A.5.
2.2.6.1 PoE injector (accessory)
The terminal is powered via Ethernet cable according to the IEEE 802.3af
PoE standard. Should the network equipment connected to the
SENCITY®Link does not offer PoE, a power injector can be inserted in line to the Ethernet cable.
2.2.6.2 Data line protector (accessory)
HUBER+SUHNER strongly recommends the installation of an outdoor data line protector to provide lightning and surge protection for the building, personnel and equipment. Please refer to the local and/or national electrical and building codes.
Outdoor
Indoor
16 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
2.2.6.3 Mast bracket (accessory)
The mast bracket is used to mount the bracket onto a mast. The bracket is suitable for any pole diameter from 50 mm to 115 mm (2” to 4,5”).
2.2.6.4 Ethernet cables (accessory)
The length of the cable linking the SENCITY®Link to the next network node may be up to 100 m (328 ft) in length. It should, however, be kept as short as practical in order to minimize signal losses. All Ethernet cables must be CAT
5e compliant and suitable for outdoor use. The cable must be UV stable, UL approved and comply with local and/or national building codes.
© 2010 HUBER+SUHNER AG 17
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
3 SITE PLANNING
Protector
PoE
Protector
PoE
18 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
All installers must perform a full site inspection and plan carefully prior to the physical installation of an SL60-3001 / SL60-4001 system.
This preparation must include:
●
Evaluating the most appropriate location for the installation of the terminal.
● Identifying an appropriate mounting structure (wall or mast) for each terminal.
●
Planning the cable routing from the network component to the terminal.
3.1 T
ERMINAL LOCATION
When selecting the best terminal location the following factors should be considered:
●
Accessibility (e.g. roof)
●
●
●
●
Type of mounting (e.g. wall or pole)
Grounding connection point
Cable runs (max. 100 m / 328 ft)
Line of sight
Use of given protection against sun, rain, etc. will increase the equipment performance.
© 2010 HUBER+SUHNER AG 19
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
3.2 L
INE OF SIGHT
To ensure a clear line of sight, there must be no obstructions between the two terminal locations. The
required clearance can be established visually using the following table 1 :
Link distance
100 m
200 m
400 m
(328 ft)
(656 ft)
Boundary diameter
0.7 m
1.0 m
(1312 ft) 1.4 m
(2.3 ft)
(3.3 ft)
(4.6 ft)
600 m
800 m
(1968 ft) 1.7 m
(2625 ft) 2.0 m
(5.6 ft)
(6.6 ft)
Boundary diameter
Link distance
3.3 L
INK DISTANCE
/ L
INK AVAILABILITY
The link distance is directly related to the weather conditions.
The affordable link availability is influenced by the following environmental conditions:
● Rain: the less, the better
●
●
Temperature: the higher, the better
Air pressure: the lower, the better
Knowledge of the link distance (line of sight) is important in estimating link quality.
1 Fresnel zone calculation
20 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
For different maps of the world including the rain regions see appendix A.4.
For a more accurate link distance vs. availability calculation please visit http://www.hubersuhner.com/sl60 where you will find an online calculation tool.
3.4 T
ERMINAL MOUNTING OPTIONS
3.4.1 Wall mounting
The wall mounting location should be strong enough to secure the terminal to the wall, taking into account all foreseeable environmental conditions (e.g. wind, rain, ice).
Depending on the material to which the bracket is mounted, differently sized mounting hardware may be necessary.
To mount the terminal onto the bracket use the enclosed M6 bolts. The bracket allows a tilt angle of +/- 50° in both axis.
50°
3.4.2 Pole mounting
The pole mounting kit will be needed to mount the terminal onto poles with diameters from 50 mm to 115 mm
(2” to 4,5”).
© 2010 HUBER+SUHNER AG 21
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
3.5 C
ABLING
The terminal is delivered with an Ethernet cable terminated with a RJ-45 plug connector. To connect the
SENCITY®Link to your network, use a CAT 5e Ethernet cable with a maximum length of 100 m to the next network node. Please verify too that the cable used is designed for outdoor environments (e.g. water, solar
UV). Since the power is supplied by the Ethernet cable, please make sure that network equipment used supports Power over Ethernet (PoE). If not, use a PoE injector according to IEEE 802.3af. SENCITY®Link can handle crossover and straight cables.
3.6 G
ROUNDING
/ L
IGHTNING PROTECTION
The terminal must be properly grounded to provide protection against voltage surges.
In the event of a short circuit or lightning strike, effective grounding can prevent damage to building, equipment, infrastructure and personnel. For installations in the USA, refer to Article 830 of the National
Electrical Code (Network-powered broadband communications systems), for all other countries, implement protection in accordance with the safety standards and regulatory requirements of the country in which the equipment is installed.
HUBER+SUHNER strongly recommends the use of outdoor lightning protectors.
22 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
3.7 C
O
-
LOCATED APPLICATIONS
Owing to the compact size of the SL60-3001 / SL60-4001 integrated terminal, it is particularly suitable for cosited applications. Possible configurations include:
● Back-to-back - e.g. doubles the link distance
● Parallel link - doubles data capacity or redundancy
● Star - hub and spoke
To deploy a co-sited application, please contact HUBER+SUHNER to assist with devising an appropriate site design.
© 2010 HUBER+SUHNER AG 23
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
4 INSTALLATION
Owing to the small size and integrated design of the SENCITY®Link, its correct installation and setup is relatively simple.
Nevertheless, when working on a roof, ladder, mast or staging, please take extreme care, observing all facility and OSHA (or other applicable regulatory agency) required safety precautions.
4.1 U
NPACKING
All equipment and installation material is packed into one box. This is divided into three cartons containing the following items:
● Carton A:
Terminal A ○
○
○
Bracket
Mounting set
●
Carton B:
○
○
○
Terminal B
Bracket
Mounting set
●
○
○
Carton C:
Manual
Reset-CD
24 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
●
○
○
Ice bridges
Accessories
Required tools:
○ Adjustable-end wrench
4.2 M
OUNT INSTALLATION
4.2.1 Wall mount
The wall and mounting screws must be able to support a weight of 11 pounds (5 kg), taking into account associated wind and potential ice loading factors.
To ensure the use of the correct screws for the installation, HUBER+SUHNER recommends consulting HILTI’s online Anchor System Advisor at http://www.us.hilti.com/holus/modules/adansel/adas_oview.jsp
Right Wrong
© 2010 HUBER+SUHNER AG 25
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
4.2.2 Mast mount
●
●
●
●
Ensure that the mast used has a diameter of between 50 mm to 115 mm (2” to 4.5”).
Use a 13 mm flat wrench (~½”) to fasten the M8 screw nut.
Fasten the alignment bracket onto front part of mast bracket using the enclosed stainless steel screws, nuts and washer (M6).
Fix the front part of the mast bracket and the attached alignment bracket on the mast.
Do not use zinc plated screws as these will corrode and endanger link performance and environment.
26 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
4.3 T
ERMINAL INSTALLATION
It is important to install the terminal on the bracket with the same orientation (i.e. antenna polarization) at both ends of the link. The terminal must be mounted on the bracket in such a way that the cable enters it on the same side, top or bottom.
The terminal must be mounted on the bracket by using the allen key with the enclosed stainless steel screws (M6 x 12).
Right
Wrong
Right
Right
Do not use zinc plated screws as these will corrode and endanger link performance and environment.
Positioning the terminal with lateral cable entry will influence heat dissipation.
4.4 C
ABLE INSTALLATION
The length of the cable from the terminal to the next network component may be up to 100 m (328 ft) in length, but should be kept as short as practical in order to reduce signal loss. All Ethernet cables must be CAT 5e compliant and suitable for outdoor use. The cable must be UV stable, UL approved and must comply with local and/or national building codes.
© 2010 HUBER+SUHNER AG 27
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
To enter the building, HUBER+SUHNER recommends using cable seals from
Roxtec (http://www.roxtec.com).
4.5 A
NTENNA ALIGNMENT
One of SENCITY®Link’s biggest advantage is its fast, easy alignment procedure.
The terminals can be aligned optically by using the alignment tool. No electrical alignment is required, although possible.
The table below shows the alignment tolerance:
Link distance Alignment accuracy
100 m 328 ft 0.9 m 2.9 ft
400 m 1312 ft 3.5 m 11.5 ft
600 m 1968 ft 5.2 m 17.2 ft
800 m 2625 ft 7.0 m 22.9 ft
Alignment accuracy
Link
dist ance
28 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
4.5.1 Alignment Procedure
The following procedure achieves fast, accurate alignment (for all operations, the enclosed 5 mm allen key can be used):
4.5.1.1 Optical alignment
a) Place the alignment tool to the most accessible corner and ensure good visibility to the opposite terminal by rotating the telescope.
b) Loosen the horizontal lock screws (labeled “3”) c) Place the horizontal axis course screw in its middle position (needle).
d) Carry out a rough alignment on the horizontal axis and fasten the screw (labeled “1”).
e) Repeat steps b), c) and d) for the vertical axis.
Horizontal alignment
Wall f) Turn the horizontal course screw (labeled
“2”) by viewing through the telescope and Vertical alignment carrying out the fine alignment.
g) Repeat e) for the vertical axis.
h) If necessary, repeat the fine alignment procedure e) for both axes until the opposite link is correctly aligned.
i) Fasten the lock screw (labeled “3”) on both horizontal and vertical axes.
2 Fine alignment
1 Coarse alignment
3 First lock
© 2010 HUBER+SUHNER AG 29
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
4.5.1.2 Power level alignment
Optionally (but recommended), an alignment based on the receiver power level of each terminal can be done. The power level can be accessed via
the web interface (see section 5.1.5).
As described in section 4.5.1.1, it is recommended
to proceed first with a rough horizontal
(respectively vertical) alignment and then to do a fine alignment on each axis. Do not forget to loosen (respectively tighten) the two lock screws before (respectively afterwards).
See chapter A.3 for an estimation of the power
levels at different rain rates and link distances.
A power level of -60dBm is better than a power level of -70dBm
4.6 G
ROUNDING
The terminal must be properly grounded.
Two screws are provided on the reverse housing of the terminal to facilitate the correct grounding. To fasten the grounding cable onto the terminal, use a lug and serrated washer combined with an M8 nut.
Connect the terminal to the connection points nearest to the building-to-earth ground point. The
30
Grounding screws
www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
grounding conductor must be as short as is practical and should not exceed 6 m (20 ft). For installations in the USA, refer to Articles 830 of the National Electrical Code (Network-powered broadband communications systems). For installations in all other countries, refer to the safety standards and regulatory requirements.
4.7 L
IGHTNING
/ S
URGE PROTECTOR
HUBER+SUHNER strongly recommends the use of outdoor data line protectors.
To protect humans and the building a protector must be installed before the cable enters the building. For detailed installation instructions, please refer to the dedicated documents enclosed to the protectors:
Outdoor protector 3414.99.0008 84016716
4.8 P
OWER INJECTOR
The power injector is connected inline into the data line. The maximum distance between the PoE and the SENCITY®Link is 100 m (328 ft). The
PoE must be IEEE 802.3af compliant. To check that the injector is functioning correctly, use the PoE Tester (see accessories order information
© 2010 HUBER+SUHNER AG 31
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5 TERMINAL MANAGEMENT AND MONITORING FUNCTIONS
For an initial configuration, use a PC or laptop. Address the terminal with the appropriate IP address.
Every terminal is labeled with its terminal type (A or B).
The factory default values are:
Terminal IP address
A
B
192.168.0.11
192.168.0.12
Subnet mask User name
255.255.255.0 admin
255.255.255.0 admin
Password sl60 sl60
To communicate with the terminal, ensure that the IP address of the computer used is not allocated automatically by the DHCP server. Configure the IP address manually - e.g. 192.168.0.1 with subnet mask 255.255.255.0.
Remember to ensure that your web browser is not using any proxy server settings.
Note:
The IP address settings have no influence on data connectivity. This settings are only needed to access the terminal monitoring functions of the terminal.
32 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5.1 W
EB BROWSER INTERFACE
5.1.1 System overview screen
This screen shows an overview of key link information including its current status.
5.1.1.1 Traffic light colors
Green:
Yellow:
Red:
System is working correctly
System is working with intermittent detection and synchronization
System is not functional
5.1.2 Password screen
Default user name:
Default password: admin sl60
© 2010 HUBER+SUHNER AG 33
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5.1.3 Firmware update screen
Current firmware can be downloaded from http://www.sl60.com or requested via technical support. The downloaded file should be saved on the local computer and then uploaded to each terminal through the firmware update form on the web interface.
5.1.4 Network configuration screen
The network configuration screen offers the option to change network settings if required. The IP address settings and VLAN settings have no influence on data connectivity.
The “Enable VLAN” check box allows the SL60-
3001 / SL60-4001 terminals to be accessed when the link is integrated into a VLAN trunk. The VLAN
ID needs to be set then too.
34 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5.1.5 Radio alignment screen
The radio alignment screen shows specific details relating to the alignment of the two terminals.
The radio history file does log (once a minute) the following parameter values for the last 48 hours:
●
Time since last reboot
Time format: <days>.<hours>:<minutes>
●
●
Receive power at time XY ("minus" sign omitted)
Device temperature in °C
● Lock detector: if unequal to 1, then the receivers are not locked
The resynchronization button can be used to restart the synchronization process with the far end terminal.
5.1.6 Network statistics screen
The network statistics screen shows standardized information relating to network traffic and errors.
Traffic status information is continuously updated and specific network errors are listed.
© 2010 HUBER+SUHNER AG 35
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5.1.7 SNMP configuration screen
The SL60-3001 / SL60-4001 terminal can be integrated into a network management system by using the implemented SNMP agent. This agent supports GET and TRAP functionality. No setting can be performed via SNMP.
Note:
To use this feature you need an SNMP manager program such as HP OpenView or Castlerock’s SNMPc.
The MIB file can be downloaded directly from the terminal.
36 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5.2 SNMP
INTERFACE
Object OID OID type
MIB-2
(iso.org.dod.internet.mgmt.mib-2.system.x / .1.3.6.1.2.1.1.x) sysDescr sysUpTime sysName
.1.
.3.
.5.
DisplayString
TimeTicks
DisplayString
Description
Includes serial no.
Uptime of the network management set in the web GUI sysLocation .6.
DisplayString set in the web GUI
HUBERSUHNER-MIB sencity
(.iso.org.dod.internet.private.enterprises.hubersuhnerOID.sencity.x / .1.3.6.1.4.1.25358.1.x) sencityLinkQuality .1.
Integer 1: Green
2: Yellow
3: Red sencityReceivePower .10.
Integer Receive signal level [dBm] sencityTemperature sencityLockDetector sencityIfEthernetIn
.11.
.12.
.15.
Integer
Integer
Integer sencityIfEthernetOut sencityIfEthernetInError sencityIfAirIn
.16.
.17.
.18.
Integer
Integer
Integer
Temperature [°C]
Lock detection signal level
Total frames received on the Ethernet interface over a period of 10 seconds.
Total frames sent on the Ethernet interface over a period of 10 seconds.
Total frames dropped due to errors received on the Ethernet interface over a period of
10 seconds.
Total frames received on the Air interface over a period of 10 seconds.
© 2010 HUBER+SUHNER AG 37
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Object sencityIfAirOut sencityIfAirInError
OID
.19.
.20.
OID type
Integer
Integer
Description
Total frames sent on the Air interface over a period of 10 seconds.
Total frames dropped due to errors received on the Air interface over a period of 10 seconds.
Installed firmware version sencityFirmwareversion .21.
String
HUBERSUHNER-MIB sencitytraps
(.iso.org.dod.internet.private.enterprises.hubersuhnerOID.sencity.sencityTraps.x / .1.3.6.1.4.1.25358.1.22.x) sencityLinkQualityImprovedTrap .1.
Integer 1: from red to green
2: from red to orange
3: from orange to green sencityLinkQualityReducedTrap .2.
Integer sencityTemperatureHighTrap sencityTemperatureLowTrap
.3.
.4.
Integer
Integer
1: from green to orange
2: from green to red
3: from orange to red
A trap indicating that the temperature within the terminal is over or below 70 degree
Celcius
A trap indicating that the temperature within the unit is over or below -40 degree Celcius
38 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5.3 R
ESET
-CD
On the Reset-CD following functions are available
● Parameter reset
●
●
Firmware upload
Documents in PDF format
This CD can be indispensable if the terminal IP address is lost or the terminal is on DHCP modus in a network where no DHCP server is available. In those cases, even though the data transmission is not influenced, the terminal monitoring functions are not accessible.
By using the parameter reset functionality it is possible to reset the terminal to the factory default IP
function (see section 5.3.1) of the CD.
This CD can be indispensable if during the firmware upload process it occurs a power breakdown or the
Ethernet connection breaks. Then it will be needed to upload the firmware via Reset-CD to the terminal.
The Reset-CD is bootable, this means the computer is started by putting the Reset-CD into the optical drive
(NOTE: the optical drive has to be defined on the computer firmware settings as a bootable device). With the
CD a Linux operating system is loaded into the computer memory, so that the communication with the embedded linux of the terminal is enabled.
System requirements:
Intel compatible CPU (i486 or later), 32 MB RAM, CD-ROM drive as bootable device, Ethernet interface.
© 2010 HUBER+SUHNER AG 39
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
5.3.1 Parameter reset
The parameter reset function will reset all terminal parameters (e.g. IP address, username, password) to the factory defaults.
5.3.2 Firmware upload
With the firmware upload functionality a firmware can be uploaded to the terminal even the previous installed firmware is lost by power breakdown or
Ethernet connectivity break during firmware upload process.
The CD contains useful documents (manual, installation video, etc.)
40 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
A TECHNICAL INFORMATION
A.1 T
ROUBLESHOOTING
This chapter provides solutions to problems that can occur during the installation and operation of the SL60-
3001 / SL60-4001. It covers various aspects of installation and network setup.
Note:
Each of the following points must be checked at both ends of the link. Start by performing the entire procedure on one side (e.g. Terminal A). If this does not solve the problem, repeat all the steps at the opposite terminal.
A.1.1 Power and network connection
You must verify that the terminal is connected to the power. The PoE injector must be installed and plugged in. Go to the terminal, disconnect the RJ-45 connector and verify if there is power in the cable using a standard PoE tester.
Take the cable and plug it into a notebook or a network testing device and verify if there is a correct network connection.
If there is any problem, please replace the cable and validate the connection again. We provide special, preassembled outdoor CAT 5e cables to ensure easy installation.
A.1.2 Network configuration
Check that the IP address is in the same range and subnet as the SL60-3001 / SL60-4001.
© 2010 HUBER+SUHNER AG 41
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Note:
The IP address of the SL60-3001 / SL60-4001 is 192.168.0.11 for Terminal A and
192.168.0.12 for Terminal B. All the computers on the network must have a unique IP address in the same range, e.g. 192.168.0.X. Any computers with identical IP addresses will not be visible on the network.
They must all, therefore, have the same subnet mask e.g. 255.255.255.0.
Do a Ping test to make sure that the SL60-3001 /
SL60-4001 is responding. Go to Start → Run →
Type “Command” → Type “ping 192.168.0.X”.
A successful Ping test will generate four replies.
As soon as the network configuration is correct you can access the GUI (Graphical User Interface) and check the settings according to section 4.9.
A.1.3 Duplex mismatch
If you encounter bad network performance, you probably have a duplex mismatch.
To ensure that the SL60-3001 / SL60-4001 terminal and the connected network component (e.g. switch) do not have a duplex mismatch you must first check your statistics.
If you find many input errors, you are on the full-duplex side; if you see many late collisions, you are on the half-duplex side.
To solve the duplex mismatch, you must manually configure both network components to the same values.
A.1.4 Miss-alignment
See the configuration interface as described in section 5.1.4. On the Radio alignment screen (see section
the correct position to track the signal. You therefore need to re-align the terminal to its opposite terminal
42 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
(please follow the instructions in section 4.5.1).
© 2010 HUBER+SUHNER AG 43
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
A.2 S
PECIFICATIONS
44 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
General system information
● Transmission Capacity: 100 Mbps Full Duplex
●
●
Interface:
Latency:
100 Base-TX
●
●
Range*:
Availability*:
< 50 µs + distance latency (1 µs / 300 m) up to 800 m (2600 ft) up to 99.999%
●
Warranty:
Connection
● Cable Length:
●
Signal Wires:
1 year max. 100 m (300 ft)
CAT 5e
●
Connector:
Mechanical data
●
Dimension:
RJ–45 (male; including outdoor Ethernet seal kit)
162 x 162 x 89 mm
(6.4“ x 6.4“ x 3.5“)
3500 g (7.7 pounds) ● Weight:
System administration
●
Management: SNMP
Web browser-based configuration
Power supply
● Standards:
● Voltage:
Compliant to Power over Ethernet according to IEEE 802.3af
± 48 V DC
●
Power Consumption: 11 W
Environmental data
● Working Temperature **: - 45 °C ... + 55 °C
(- 49 °F … + 131 °F)
© 2010 HUBER+SUHNER AG 45
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
●
●
Storage Temperature: - 30 °C … + 55 °C
(- 22 °F … + 131 °F)
Wind Load: operating survival
160 km/h (100 mph)
200 km/h (125 mph)
Regulatory
● Regulatory Compliance:
FCC Part 15
Industry Canada RSS210
R&TTE Directive 1999/5/EC
Ordering information
●
SL60-3001: Item # 84057630
SL60-4001: Item # 84064720 each composed of: 2 Terminals
2 Alignment brackets
1 Manual
2 Mounting sets
1 Reset-CD
2 Ice bridges
* The range depends on the climate zone and the requested availability
** Only if the terminal is powered up
46 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
A.2.1 Ethernet cable colour code
Note:
By cutting of the connector the warranty will expire.
6
7
8
3
4
5
Pin
1
2
Name
TX+
TX-
RX+
Power+
Power+
RX-
Power-
Power-
RJ45 Plug
Black
Green
Red
Blue
White
Orange
Yellow
Brown
Twisted pairs:
● Black / Green
●
●
●
Yellow / Brown
Red / Orange
Blue / White
© 2010 HUBER+SUHNER AG 47
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
A.3 R
ECEIVER LEVEL
/ R
AIN
/ L
INK DISTANCE
The following diagram shows the approximate receiver levels at different rain rates and distances. This diagram is valid for A and B terminals delivered with firmware version 1.40 or higher.
SL60-3001
SL60-4001
48 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
A.4 A
VAILABILITY
/ R
AIN ZONE
/ L
INK DISTANCE
A.4.1 Map of America
© 2010 HUBER+SUHNER AG 49
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
The link distance is directly related to the weather conditions. The tables below refer to a link working at a distance of up to 600m (SL60-3001) resp. 800m (SL60-4001), for dry weather conditions.
600m (SL60-3001):
Availability
99%
99.9%
Rain zone *
Link distance (m)
G H J A B C D E F K L M N P Q
598 593 591 576 592 580 569 577 534 582 577 561 554 512 463
577 569 554 534 547 534 512 523 477 512 498 470 429 366 355
99.99% 534 512 498 481 470 450 443 438 429 412 375 370 325 278 304
99.999% 470 438 412 412 358 346 366 340 384 319 274 299 255 221 261
800m (SL60-4001):
Availability
99%
99.9%
Rain zone *
Link distance (m)
G H J A B C D E F K L M N P Q
797 789 785 764 787 770 752 765 701 772 765 741 730 669 597
765 752 730 701 719 701 669 684 618 669 648 607 549 461 446
99.99% 701 669 648 624 607 578 569 561 549 524 473 466 405 343 376
99.999% 607 561 524 524 450 434 461 425 486 397 338 370 312 268 320
* Rain zone according to ITU-R Recommendation PN.837-1
99.9% availability equates to 526 minutes per year of outage due to heavy rains.
99.99% availability equates to 53 minutes per year of outage due to heavy rains.
99.999% availability equates to 5 minutes per year of outage due to heavy rains.
50 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
A.4.2 Map of Asia and Middle East
© 2010 HUBER+SUHNER AG 51
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
The link distance is directly related to the weather conditions. The tables below refer to a link working at a distance of up to 600m (SL60-3001) resp. 800m (SL60-4001), for dry weather conditions.
600m (SL60-3001):
Availability
99%
99.9%
Rain zone *
Link distance (m)
G H J A B C D E F K L M N P Q
598 593 591 576 592 580 569 577 534 582 577 561 554 512 463
577 569 554 534 547 534 512 523 477 512 498 470 429 366 355
99.99% 534 512 498 481 470 450 443 438 429 412 375 370 325 278 304
99.999% 470 438 412 412 358 346 366 340 384 319 274 299 255 221 261
800m (SL60-4001):
Availability
99%
99.9%
Rain zone *
Link distance (m)
G H J A B C D E F K L M N P Q
797 789 785 764 787 770 752 765 701 772 765 741 730 669 597
765 752 730 701 719 701 669 684 618 669 648 607 549 461 446
99.99% 701 669 648 624 607 578 569 561 549 524 473 466 405 343 376
99.999% 607 561 524 524 450 434 461 425 486 397 338 370 312 268 320
* Rain zone according to ITU-R Recommendation PN.837-1
99.9% availability equates to 526 minutes per year of outage due to heavy rains.
99.99% availability equates to 53 minutes per year of outage due to heavy rains.
99.999% availability equates to 5 minutes per year of outage due to heavy rains.
52 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
A.4.3 Map of Europe
© 2010 HUBER+SUHNER AG 53
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
The link distance is directly related to the weather conditions. The tables below refer to a link working at a distance of up to 600m (SL60-3001) resp. 800m (SL60-4001), for dry weather conditions.
600m (SL60-3001):
Availability
99%
99.9%
Rain zone *
Link distance (m)
G H J A B C D E F K L M N P Q
598 593 591 576 592 580 569 577 534 582 577 561 554 512 463
577 569 554 534 547 534 512 523 477 512 498 470 429 366 355
99.99% 534 512 498 481 470 450 443 438 429 412 375 370 325 278 304
99.999% 470 438 412 412 358 346 366 340 384 319 274 299 255 221 261
800m (SL60-4001):
Availability
99%
99.9%
Rain zone *
Link distance (m)
G H J A B C D E F K L M N P Q
797 789 785 764 787 770 752 765 701 772 765 741 730 669 597
765 752 730 701 719 701 669 684 618 669 648 607 549 461 446
99.99% 701 669 648 624 607 578 569 561 549 524 473 466 405 343 376
99.999% 607 561 524 524 450 434 461 425 486 397 338 370 312 268 320
* Rain zone according to ITU-R Recommendation PN.837-1
99.9% availability equates to 526 minutes per year of outage due to heavy rains.
99.99% availability equates to 53 minutes per year of outage due to heavy rains.
99.999% availability equates to 5 minutes per year of outage due to heavy rains.
54 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
A.5 A
CCESSORIES ORDER INFORMATION
Item number
23033695
Description
Data Line Protector (indoor)
To use only in combination with an outdoor protector.
84014284 Data Line Protector (outdoor)
84021330 PoE 802.3af Tester
© 2010 HUBER+SUHNER AG 55
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Item number
84021333
84016575
84015652
84016596
Description
PoE 802.3af Power Injector
SENCITY®Link Alignment Bracket
Mast Bracket
Visual Alignment Tool
56 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
Item number
84022128
84031068
84028025
84028026
84028029
84034955
84044851
Description
Ice Bridge
Outdoor Ethernet Cable 2 m
Outdoor Ethernet Cable 10 m
Outdoor Ethernet Cable 30 m
Outdoor Ethernet Cable 90 m
Encryption Box HiSec 220
Sealed Ethernet connection RJ45
© 2010 HUBER+SUHNER AG 57
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
B COUNTRY SPECIFIC INFORMATION
B.1.1 Switzerland, Germany
B.1.1.1 English
Indication about the correct use of the system
The devices of this system establish a wireless point to point data connection.
Indication about possible application limitations
Operation on NIB / NPB (Non interference basis / non protection basis): The equipment is not permitted to cause harmful interference to other radio services. The equipment has to be switched off immediately in the case of interference with other services.
Indication about the network interfaces to which the system can be connected
The devices are intended to be connected to IEEE standard 802.3af (Power over Ethernet) compliant devices. SL60-3001 / SL60-4001 has to be supplied by a limited power source according to EN 60950-
1:2006.
B.1.1.2 Deutsch
Hinweis auf bestimmungsgemässe Verwendung der Anlage
Die Geräte dieser Anlage stellen eine drahtlose Punkt-zu-Punkt Datenverbindung her.
Hinweis auf mögliche Verwendungseinschränkungen
Interferenzen und Schutzvorkehrungen im Betrieb: Die Ausrüstung ist nicht gestattet, andere Funkdienste nachteilig zu stören. Das Gerät muss im Falle von Interferenzen mit anderen Diensten sofort ausgeschaltet werden.
Hinweis auf die Netzschnittstellen, an welche die Anlage angeschlossen werden kann
Die Geräte sind für den Anschluss an dem IEEE-Standard 802.3af (Power over Ethernet) konforme Geräte
58 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
bestimmt. SL60-3001 / SL60-4001 muss durch eine Stromquelle begrenzter Leistung gemäss EN 60950-
1:2006 gespiesen werden.
B.1.1.3 Français
Indication concernant l‘utilisation correcte de l‘installation
L’équipement de cette installation établis une liaison de données point à point sans fil.
Indication concernant de possible restrictions de l‘utilisation
Interférence et protection pendant le fonctionnement: Le matériel n’est pas permis de causer des interférences nuisibles à d’autres services radio. Le matériel doit être mis hors service immédiatement dans le cas d’interférence avec d’autres services.
Indication concernant les interfaces du réseau auxquelles l‘installation peut être raccordé
L’équipement est conçu pour le raccordement aux appareils conformes au standard IEEE 802.3af (Power over Ethernet). SL60-3001 / SL60-4001 doit être alimenté par une source de courant fini selon EN 60950-
1:2006.
B.1.1.4 Italiano
Indicazione concernente l’utilizzo corretto e l’installazione
Le componenti installate di questo sistema creano un ponte radio punto-punto.
Indicazione concernente le possibili restrizioni dell’utilizzo
Interferenze e protezione durante l’utilizzo: il sistema non deve causare alcuna interferenza nociva ad altri servizi radio. Questo sistema deve essere spento immediatamente nel caso di interferenza con altri servizi.
Indicazione concernente le interfacce alle quali il sistema può essere connesso
Il sistema è concepito per essere connesso all’interfaccia conforme allo standard IEEE 802.3af (Power over
Ethernet). SL60-3001 / SL60-4001 deve essere alimentato da un’alimentazione conforme alle specifica EN
60950-1:2006.
© 2010 HUBER+SUHNER AG 59
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
C CONTACTS
C.1.1 Technical assistance
Please visit http://www.sl60.com
C.1.2 Service center / RMA
USA / Canada toll free phone number:
1-800-348-9008
60 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
D GLOSSARY
DHCP
DNS
CE
Dynamic Host Configuration
Protocol
DHCP enables both manual and automatic IP address allocation in a network.
Domain Name System enables the translation from IP address to domain name
The CE marking is a conformity mark on products placed on market in the European Economic Area.
FCC
IP
LAN
Federal Communication
Commission (USA)
Internet Protocol
Local Area Networks
LOS Line of Sight – uninterrupted, visual, point-to-point contact.
MAC address Media Access Control
OSHA
PoE
QPSK physical, unique address of network component
Occupational Safety and Health
Administration
Power over Ethernet according to
IEEE 802.3af that provides for a standardized power model.
Quadrature Phase Shift Keying
SNMP
TCP
WAN
WLAN
Simple Network Management
Protocol
Transmission Control Protocol
Wide Area Network
Wireless Local Area Network. This typically unlicensed non line of site application operates in the frequency range 2 - 6 GHz according to IEEE 802.11x.
© 2010 HUBER+SUHNER AG 61
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
E NOTES
62 www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
HUBER+SUHNER (Australia) Pty. Ltd.
Unit 6, 4 Skyline Place
Frenchs Forest
Sydney NSW 2086 (Australia)
Telefon: +61 2 8977 1200
Fax: +61 2 9972 7549
E-Mail: [email protected]
HUBER+SUHNER GmbH
Mehlbeerenstrasse 6
Postfach 1263
82019 Taufkirchen (Germany)
Telefon: +49 89 6 12 01-0
Fax: +49 89 6 12 01162
E-Mail: [email protected]
HUBER+SUHNER Electronics Pvt. Ltd.
359, Udyog Vihar, Phase II
Gurgaon 122016
Haryana (India)
Telefon: +91 124 5102701/02/03
Fax: +91 124 5102704
E-Mail: [email protected]
HUBER+SUHNER América Latina Ltda.
HUBER+SUHNER A/S
Avenida Rui Barbosa, 3613 Kirke Værløsevej 14
Alto da Ponte
Sao José dos Campos -
SP 12213 300 (Brazil)
3500 Værløse (Denmark)
Telefon: +45 48 100 500
Fax: +45 48 100 555
E-Mail: [email protected]
Telefon: +55 12 3946 9 500
Fax: +55 12 3946 9 527
E-Mail: [email protected]
HUBER + SUHNER France
21 E, rue Jacques CARTIER
78960 Voisins le Bretonneux (France) HUBER+SUHNER (Canada) Ltd.
2650 Queensview Drive
Suite 206
Ottawa ON K2B 8H6 (Canada)
Telefon: +33 1 61 37 25 55
Fax: +33 1 30 64 73 68
E-Mail: [email protected]
Telefon: +1 613 721 4111
Fax: +1 613 721 8480
E-Mail: [email protected]
HUBER+SUHNER AG
Degersheimerstrasse 14
Postfach
9100 Herisau (Switzerland)
Telefon: +41 71 353 4111
Fax: +41 71 353 4444
E-Mail: [email protected]
Website: www.hubersuhner.com
HUBER+SUHNER (Hong Kong) Ltd.
Suite 1601, 16/F
Chung Nam Building
1 Lockhart Road
Wanchai, Hong Kong (China)
Telefon: +852 2866 6600
Fax: +852 2866 6313
E-Mail: [email protected]
HUBER+SUHNER AB
Knarrarnäsgatan 7
Box 1247
SE 164 28 Kista, Stockholm (Sweden)
Telefon: +46 8 447 5200
Fax: +46 8 447 5201
E-Mail: [email protected]
HUBER+SUHNER (Singapore) Pte. Ltd.
Number 8, Tuas Avenue 5
Singapore 639334 (Singapore)
Telefon: +65 6861 8186
Fax: +65 6861 3316
E-Mail: [email protected]
HUBER+SUHNER (UK) Ltd.
Telford Road
Bicester Oxfordshire OX26 4LA (UK)
Telefon: +44 1869 364 100/101
Fax: +44 1869 249 046
E-Mail: [email protected]
HUBER+SUHNER Inc.
19 Thompson Drive
Essex VT 05452 (USA)
Telefon: +1 802 878 0555
Fax: +1 802 878 9880
E-Mail: [email protected]
© 2010 HUBER+SUHNER AG 63
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
HUBER+SUHNER is certified according to
ISO 9001, ISO 14001, ISO/TS 16949 and IRIS.
WAIVER
It is exclusively in written agreements that we provide our customers with warrants and representations as to the technical specifications and/or the fitness for any particular purpose. The facts and figures contained herein are carefully compiled to the best of our knowledge, but they areintended for general informational purposes only.
64 hubersuhner.com
www.hubersuhner.com
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299
advertisement
Key Features
- Full duplex data rate of 100 Mbps
- Range up to 800 m (2600 ft)
- Easy installation
- Compact size
- Web browser based configuration and monitoring
- SNMP interface
- Power over Ethernet (PoE) support