Relay Control Relay 2. Type designation N JJ 6 /□ Rated control supply voltage Design sequence No. Counting relay Company feature code Note: Some models of this product apply to a wide range of operational voltage. For example, an operational voltage of AC/DC100V~240V means that it can operate normally within the voltage range of AC or DC 100V to 240V. 3. Technical data Operational voltage 85%-110% of rated voltage AC 50Hz/60Hz AC/DC100V-240V, DC24V Electrical life 1×10 Mechanical life 1×10 5 6 1 group of change-over contacts Output mode NJJ6 Counting Relay Ue/Ie: AC-15 220V/0.75A, 380V/0.47A; Contact capacity DC-13 220V/0.27A; Ith:5A 1. General NJJ6 counting relay is used to provide counting and counting control in control circuits with an AC frequency of 50Hz/60Hz and a rated control voltage of up to 240V and control circuits with a DC rated control supply voltage of up to 240V. 6-digit counting relay (the upper 6-digit Counting digits LCD is the count value, the lower 6-digit LCD is the preset value) 1 time/second, 30 times/second, Counting rate 1000 times/second (can be set) Addition, subtraction, reversible A, Counting mode reversible B, reversible C Contact input, sensor input Input signal (NPN type/PNP type can be set) Value setting Can be set within the range 0.001~99.999 Output mode N, F, C, R, K, P, Q, A The output time can be set Output time within 0.01s~9.99s (under output mode C, R, K, P ,Q or A) Ambient temperature -5℃~+40℃ Power consumption 3VA Mounting type Panel type Overall dimensions W58×H48×L97mm Opening size W45.5×H45.5mm More than 10 years (can be set) Power-off memory 4. Wiring diagram INA 6 INB Reset Pause 0VDC 7 8 9 10 12VDC 30mA 12 11 1 (+) (~) 89 >> Empower the World 3 2 Power (-) (~) 4 5 Output Relay Control Relay 5. Overall and mounting dimensions (mm) 45.5 97max 58max 复位 45.5 48max R 设置 NJJ6 计数继电器 6. Sequence diagram of counting mode Counting mode Timing-sequence diagram Remark INA INB Count at INA rising edge, 5 stop counting at INB input. 4 3 Count value 2 1 0 V Addition counting mode INA INB Count at INB input 5 4 Count value falling edge at INA input. 3 2 1 0 INA INB INA上升沿计数, Count at INA rising edge, INB输入停止计数。 n n-1 n- 2 stop counting at INB input. n-3 Count value n-4 n-5 *n Preset value Subtraction counting mode D INA INB Count at INB input n n-1 INA输入时, INB输入下降沿计数。 falling edge at INA input. n-2 n-3 Count value n-4 n-5 *n Preset value INA Reversible counting mode A: INB Addition counting at INA input, Reversible counting mode A U D A subtraction counting when Count value 2 1 3 3 2 1 2 INB input is active. 0 Empower the World >> 90 Relay Control Relay Timing-sequence diagram Counting mode Remark INA Reversible counting mode B: INB Reversible counting mode B U D B Addition counting at INA input, Count value 0 3 2 1 2 1 1 subtraction counting at INB input. 3 2 INA Reversible counting mode C: INB Automatic recognition of positive Reversible counting mode C U D C and reverse rotations, addition Count value 0 2 1 3 2 2 1 3 and subtraction counting. 7. Sequence diagram of output mode Output mode (N) Plus counting mode Minus counting mode Reset Reset Reset Preset value Preset value Preset value Count value Count value Count value 0 0 Reset Reset Reset Preset value Preset value Count value Count value Count value 0 0 Reset Reset Reset Preset value Preset value Count value Count value Count value 0 0 0 Output Output t t t t Reset Reset Reset Preset value Preset value Preset value Count value Count value Count value 0 0 Output Empower the World t t 0 Output t >> Output Preset value t 91 0 Output Output (R) Output Preset value Output (C) 0 Output Output (F) Inverse counting mode A, B, C Output t t t t Relay Control Relay Output mode (K) Plus counting mode Minus counting mode Reset Reset Reset Preset value Preset value Preset value Count value Count value Count value 0 0 Output t t Reset Reset Reset Preset value Preset value Preset value Count value Count value Count value 0 0 Output t t t t Reset Reset Reset Preset value Preset value Preset value Count value Count value Count value 0 0 Output Output t t t t Reset Reset Reset Preset value Preset value Preset value Count value Count value Count value 0 0 Output t t 0 Output t t 0 Output t t 0 Output t (A) Output t t Output (Q) 0 Output t (P) Inverse counting mode A, B, C Output t t t t Note: t is the output time, which can be set by the user. Empower the World >> 92
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement