RISCO Agility 2 security system Engineer Manual

RISCO Agility 2 security system Engineer Manual

The Agility 2 is a versatile wireless security system that offers a wide range of features and customization options. It is ideal for both residential and commercial applications and can be easily integrated with existing security systems. The Agility 2 system includes 32 wireless zones, 3 partitions, up to 3 bi-directional wireless keypads, and up to 8 remote control keyfobs. It also supports a variety of one-way and two-way wireless security and safety devices, keypads, remote controls, keyfobs, panic buttons, fully wireless sounders, and other accessories. The Agility 2 system is compatible with RISCO Group’s extensive range of wireless security and safety devices.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

RISCO Agility 2 Engineer Manual | Manualzz
ȱ
Engineer Manual
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
`ȱ
AgilityȱEngineerȱManual
ȱ
Important Notice
Thisȱguideȱisȱdeliveredȱsubjectȱtoȱtheȱfollowingȱconditionsȱandȱrestrictions:ȱ
ThisȱguideȱcontainsȱproprietaryȱinformationȱbelongingȱtoȱRISCOȱGroup.ȱSuchȱ
informationȱisȱsuppliedȱsolelyȱforȱtheȱpurposeȱofȱassistingȱexplicitlyȱandȱproperlyȱ
authorizedȱusersȱofȱtheȱsystem.ȱ
Noȱpartȱofȱitsȱcontentsȱmayȱbeȱusedȱforȱanyȱotherȱpurpose,ȱdisclosedȱtoȱanyȱpersonȱ
orȱfirm,ȱorȱreproducedȱbyȱanyȱmeans,ȱelectronicȱorȱmechanical,ȱwithoutȱtheȱexpressȱ
priorȱwrittenȱpermissionȱofȱRISCOȱGroup.ȱ
Theȱinformationȱcontainedȱhereinȱisȱforȱtheȱpurposeȱofȱillustrationȱandȱreferenceȱ
only.ȱ
Informationȱinȱthisȱdocumentȱisȱsubjectȱtoȱchangeȱwithoutȱnotice.ȱ
Corporateȱandȱindividualȱnamesȱandȱdataȱusedȱinȱexamplesȱhereinȱbelongȱtoȱtheirȱ
respectiveȱowners.ȱ
Compliance Statement
Hereby,ȱRISCOȱGroupȱdeclaresȱthatȱtheȱAgilityȱseriesȱofȱcentralȱunitsȱandȱaccessoriesȱareȱ
designedȱtoȱcomplyȱwith:ȱ
EN50131Ȭ1,ȱEN50131Ȭ3ȱGradeȱ2ȱ
EN50130Ȭ5ȱEnvironmentalȱclassȱIIȱȱ
EN50131Ȭ6ȱTypeȱAȱ
UK:ȱDD243:2004,ȱPDȱ6662:2004,ȱACPOȱ(Police)ȱ
USA:ȱFCC:ȱPartȱ15B,ȱFCCȱpartȱ68ȱȱ
CANADA:ȱCSȬ03,ȱDCȬ01ȱ
ȱ
ȱ
Allȱrightsȱreserved.ȱȱ
”ȱ2010ȱRISCOȱGroupȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱMarchȱ2010ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Page ii
AgilityȱEngineerȱManualȱ
ȱ
ȱ
ȱ
Table of Contents
CHAPTERȱ1ȱINTRODUCTION ................................................................................................1-1ȱ
ARCHITECTURE ............................................................................................................................1-2ȱ
MAINȱFEATURES...........................................................................................................................1-3ȱ
TECHNICALȱSPECIFICATIONS........................................................................................................1-4ȱ
CHAPTERȱ2ȱINSTALLINGȱTHEȱAGILITY.............................................................................2-1ȱ
AGILITYȱMAINȱCOMPONENTS ......................................................................................................2-1ȱ
MOUNTINGȱTHEȱAGILITY .............................................................................................................2-2ȱ
Choosingȱtheȱmountingȱlocation ..............................................................................................2-2ȱ
WallȱMountingȱtheȱAgility ......................................................................................................2-2ȱ
ConnectingȱtheȱBackupȱBattery ...............................................................................................2-5ȱ
ConnectingȱtheȱAgilityȱtoȱPowerȱSupplyȱȬȱConfigurationȱA ...................................................2-6ȱ
GroundȱConnection..................................................................................................................2-6ȱ
ConnectingȱtheȱAgilityȱtoȱPowerȱSupplyȱȬȱConfigurationȱB....................................................2-7ȱ
CompletingȱInstallation ...........................................................................................................2-8ȱ
DIPȱswitchȱsetting ...................................................................................................................2-8ȱ
ConnectingȱaȱtelephoneȱlineȱtoȱtheȱAgility ...............................................................................2-9ȱ
ConnectingȱaȱnetworkȱcableȱtoȱtheȱAgility .............................................................................2-10ȱ
SIMȱCardȱInstallation............................................................................................................2-11ȱ
ExternalȱAudioȱUnit ..............................................................................................................2-12ȱ
CHAPTERȱ3ȱENGINEERȱPROGRAMMING..........................................................................3-1ȱ
PROGRAMMINGȱMETHODS ...........................................................................................................3-1ȱ
ConfigurationȱSoftware............................................................................................................3-1ȱ
WirelessȱKeypad.......................................................................................................................3-1ȱ
EngineerȱKeypad ......................................................................................................................3-2ȱ
PTM:ȱDataȱStoringȱDevice ......................................................................................................3-2ȱ
WIRELESSȱDEVICEȱALLOCATION ..................................................................................................3-4ȱ
QuickȱAllocationȱusingȱtheȱmainȱunitȱbutton..........................................................................3-4ȱ
Allocationȱusingȱtheȱkeypad .....................................................................................................3-4ȱ
AllocationȱusingȱtheȱConfigurationȱSoftware ..........................................................................3-5ȱ
TransmittersȱWriteȱMessageȱMethod ......................................................................................3-7ȱ
DELETINGȱWIRELESSȱACCESSORIES ..............................................................................................3-7ȱ
CHAPTERȱ4ȱENGINEERȱMENUS ............................................................................................4-1ȱ
USINGȱTHEȱAGILITYȱKEYPADȱKEYS ...............................................................................................4-1ȱ
ACCESSINGȱTHEȱENGINEERȱMENUS .............................................................................................4-2ȱ
Page iii
`ȱ
AgilityȱEngineerȱManual
ȱ
PROGRAMMINGȱMENU.................................................................................................................4-2ȱ
1.ȱProgramming:ȱSystemȱMenu...............................................................................................4-2ȱ
1.1ȱTimers ...........................................................................................................................4-3ȱ
1.2ȱControls ........................................................................................................................4-5ȱ
1.3ȱLabels ..........................................................................................................................4-14ȱ
1.4ȱSounds ........................................................................................................................4-15ȱ
1.5ȱSettings........................................................................................................................4-16ȱ
1.6ȱServiceȱInformation...................................................................................................4-17ȱ
1.7ȱFirmwareȱUpdate ......................................................................................................4-17ȱ
2.ȱProgramming:ȱRadioȱDevicesȱMenu..................................................................................4-18ȱ
2.1ȱAllocation ...................................................................................................................4-18ȱ
2.2ȱModification...............................................................................................................4-18ȱ
2.3ȱIdentification ..............................................................................................................4-41ȱ
3.ȱProgramming:ȱCodesȱMenu ...............................................................................................4-42ȱ
3.1ȱUser .............................................................................................................................4-42ȱ
3.2ȱGrandȱMaster .............................................................................................................4-43ȱ
3.3ȱEngineer......................................................................................................................4-43ȱ
3.4ȱSubȬEngineer..............................................................................................................4-43ȱ
3.5ȱCodeȱLength...............................................................................................................4-44ȱ
3.6ȱDTMFȱCode................................................................................................................4-44ȱ
3.7ȱParentȱControl............................................................................................................4-44ȱ
4.ȱProgramming:ȱCommunicationȱMenu...............................................................................4-45ȱ
4.1ȱMethod........................................................................................................................4-45ȱ
4.2ȱAlarmȱReceivingȱCenter ...........................................................................................4-53ȱ
4.3ȱConfigurationȱSoftware ............................................................................................4-59ȱ
4.4ȱFollowȬMe ..................................................................................................................4-61ȱ
5.ȱProgramming:ȱAudioȱMessagesȱMenu ..............................................................................4-67ȱ
5.1ȱAssignȱMessage .........................................................................................................4-67ȱ
5.2ȱLocalȱMessage ............................................................................................................4-67ȱ
TESTINGȱMENU ...........................................................................................................................4-69ȱ
1.ȱMainȱUnit ..........................................................................................................................4-69ȱ
2.ȱZone ...................................................................................................................................4-70ȱ
3.ȱRemoteȱControlȱ(Keyfob)....................................................................................................4-70ȱ
4.ȱKeypad................................................................................................................................4-71ȱ
5.ȱSounder ..............................................................................................................................4-71ȱ
6.ȱGSM...................................................................................................................................4-72ȱ
7.ȱIPȱUnit ...............................................................................................................................4-72ȱ
8.ȱPOȱUnit .............................................................................................................................4-73ȱ
ACTIVITIESȱMENU ......................................................................................................................4-74ȱ
FOLLOWȱMEȱMENU ....................................................................................................................4-75ȱ
Page iv
AgilityȱEngineerȱManualȱ
ȱ
ȱ
CLOCKȱMENU ............................................................................................................................4-75ȱ
EVENTȱLOGȱMENU .....................................................................................................................4-76ȱ
MACROȱMENU ...........................................................................................................................4-76ȱ
ProgrammingȱMacroȱKeys.....................................................................................................4-76ȱ
ActivatingȱaȱMacro ................................................................................................................4-77ȱ
APPENDIXȱAȱREPORTȱCODES...............................................................................................AȬ1ȱ
APPENDIXȱBȱENGINEERȱEVENTȱLOGȱMESSAGES ......................................................... BȬ1ȱ
APPENDIXȱCȱLIBRARYȱVOICEȱMESSAGES .......................................................................CȬ1ȱ
APPENDIXȱDȱENȱ50131ȱCOMPLIANCE ............................................................................... DȬ1ȱ
APPENDIXȱEȱINSTALLERȱPROGRAMMINGȱMAPS ........................................................ EȬ1ȱ
UKȱ
UKUKUKUKUKUKUKUK
Page v
AgilityȱEngineerȱManualȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ
ȱ
Chapter 1 Introduction
TheȱAgilityȱisȱaȱFlexibleȱWirelessȱSecurityȱSolutionȱthatȱincorporatesȱstateȬofȬtheȬartȱ
wirelessȱandȱcommunicationȱtechnology.ȱȱAgilityȱisȱidealȱforȱinstallationȱinȱanyȱhomeȱorȱ
officeȱenvironmentȱandȱsupportsȱRISCOȱGroup’sȱextensiveȱrangeȱofȱoneȬwayȱandȱtwoȬwayȱ
wirelessȱsecurityȱandȱsafetyȱdevices,ȱkeypads,ȱremoteȱcontrols,ȱkeyfobs,ȱpanicȱbuttons,ȱ
fullyȱwirelessȱsoundersȱandȱotherȱaccessories.ȱ
MainȱBenefits:ȱ
FlexibleȱPlugȬinȱCommunicationȱȱ
™
™
™
IPȱModuleȱ
GSM/GPRSȱModuleȱ
FastȱPSTNȱModuleȱ
Useȱanyȱsingleȱmodule,ȱanyȱcombinationȱorȱallȱthreeȱmodulesȱforȱbackup,ȱorȱnoȱ
communicationȱforȱaudibleȱonlyȱinstallationsȱ
2ȬWayȱWirelessȱKeypadȱwithȱfullȱprogrammingȱcapabilityȱ
2ȬWayȱ8ȱbuttonȱWirelessȱRemoteȱControlȱwithȱcodeȱprotection,ȱkeyȬlockȱandȱ
systemȱstatusȱrequestȱandȱindicationȱ
2Ȭwayȱvoiceȱcommunicationȱ
EasyȱenrollingȱofȱWirelessȱDevicesȱwithoutȱaȱkeypadȱ
RemoteȱenrollingȱaccordingȱtoȱDeviceȱIDȱ
Combineȱone–wayȱorȱtwoȬwayȱtransmittersȱinȱtheȱsameȱsystemȱ
Flashȱmemoryȱforȱeasyȱfirmwareȱupgradeȱȱ
Simpleȱphysicalȱinstallationȱwithȱwallȱbracketsȱ
Separateȱmainȱpanel,ȱcanȱbeȱhiddenȱforȱhigherȱsecurityȱ
ProgramȱTransferȱModuleȱ(PTM)ȱforȱprogramȱbackupȱ
Simplifiedȱmenuȱlogicȱ(onlyȱmenusȱofȱinstalledȱdevicesȱareȱdisplayed,ȱonlyȱ
menusȱaccordingȱtoȱtheȱauthorizationȱcodeȱareȱdisplayed)ȱȱ
MainȱFeatures:ȱ
32ȱwirelessȱzonesȱ
3ȱpartitionsȱ
Upȱtoȱ3ȱbiȬdirectionalȱwirelessȱkeypadsȱ
Upȱtoȱ8ȱRemoteȱControlȱkeyfobsȱ(combinationȱofȱ8ȱorȱ4ȱbutton)ȱorȱoneȱwayȱ
Input/Outputȱmodule:ȱ
™
™
™
™
2ȬwayȱwirelessȱcommunicationȱtoȱtheȱAgilityȱ
Localȱtransformerȱwithȱrechargeableȱbackupȱbatteriesȱ
4ȱwiredȱzonesȱwithȱselectableȱEOLȱresistanceȱ&ȱ4ȱoutputsȱ(2x3Aȱrelayȱandȱ2x500mA)ȱ
IncludesȱXȬ10ȱconnectionȱȱ
32ȱuserȱcodesȱ
250ȱeventȱlogȱ
UsesȱregularȱSealedȱLeadȱAcidȱBatteryȱ6Vȱ3.2ȱAh.ȱȱ
Page 1-1
AgilityȱEngineerȱManualȱ
ȱ
Architecture
TheȱfollowingȱdiagramȱprovidesȱanȱoverviewȱofȱtheȱAgilityȇsȱarchitectureȱandȱcapabilities.ȱ
ExamineȱtheȱfigureȱbeforeȱbeginningȱwithȱyourȱAgilityȱinstallationȱtoȱobtainȱanȱoverallȱ
pictureȱofȱtheȱfullȱextentȱofȱtheȱAgilityȱsystemȱcapabilities.ȱ
Note:ȱTheȱwebȱbrowserȱfeatureȱwillȱbeȱavailableȱforȱuserȱmonitoringȱinȱfutureȱversionsȱofȱAgility.ȱ
Page 1-2
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Main Features
TheȱfollowingȱillustrationȱdescribesȱtheȱmainȱfeaturesȱofȱtheȱAgility:ȱ
Detectorsȱ
x 32ȱWirelessȱzones:ȱȱ
x 4ȱWiredȱzonesȱviaȱ
optionalȱWirelessȱI/Oȱ
Expanderȱ
x Totalȱzones:ȱ36ȱ
x Moreȱthanȱ25ȱzoneȱ
typesȱ
x Fullȱzoneȱsupervisionȱȱ
x 2Ȭwayȱandȱ1Ȭwayȱ
detectorsȱcombinedȱonȱ
theȱsameȱsystemȱ
Soundersȱ
x BuiltȬinȱsounderȱ
x Fullyȱwirelessȱexternalȱ
andȱinternalȱwirelessȱ
soundersȱ
x Addȱupȱtoȱ3ȱSoundersȱȱ
AlarmȱReceivingȱCenterȱ
x Remoteȱprogramming,ȱ
diagnosticsȱandȱ
communicationȱtest.ȱ
x Reportȱtoȱ3ȱARC.ȱ
x ReportȱthoughtȱPSTN,ȱ
GSM,ȱGPRSȱorȱIP.ȱ
x ARCȱpollingȱthroughȱIPȱ
network.ȱ
x Accountȱnumberȱforȱ
eachȱARC.ȱ
x Flexibleȱsplitȱreportingȱ
forȱbackup.ȱ
x CallȱSaveȱmodeȱforȱnonȬ
urgentȱreports.ȱ
x Remoteȱdeviceȱ
enrollment.ȱ
Communication:ȱ
x Flexibleȱcommunicationȱ
overȱGSM/GPRS,ȱIPȱorȱ
PSTN.ȱȱ
x Backupȱcapabilityȱ
betweenȱtheȱ
communicationȱmethods.ȱ
x Supportsȱmajorȱreportingȱ
formats.ȱ
x Addȱonȱmoduleȱforȱeachȱ
communicationȱtype.ȱ
EngineerȱProgramming:ȱ
x Localȱ/Remoteȱusingȱ
configurationȱsoftwareȱ
x Programȱtransferȱ
module.ȱ
x Fullȱprogrammingȱusingȱ
biȬdirectionalȱwirelessȱ
keypad.ȱ
x Flexibleȱdeviceȱ
enrollmentȱbyȱserialȱIDȱ
serialȱnumberȱorȱbyȱRFȱ
allocation.ȱ
x Keypadȱprogrammingȱ
menuȱadjustedȱtoȱ
existingȱhardware.ȱ
BiȬdirectionalȱKeypadȱ
x FullyȱWirelessȱȱ
x LCDȱdisplayȱ
x S.O.Sȱ/ȱTwoȱwayȱ
communicationȱ
emergencyȱkeyȱ
x Doubleȱtamperȱ
protectionȱ(Boxȱ&ȱ
Wall)ȱȱ
ȱ
UserȱOperatingȱTools:ȱ
x BiȬdirectionalȱ8ȱbuttonȱ
keyȱfobȱ
x BiȬdirectionalȱKeypadȱ
x 4ȱbuttonȱkeyfobȱ
x Remoteȱphoneȱoperationȱ
x SMSȱ
x Configurationȱsoftwareȱ
x Webȱbrowserȱ(willȱbeȱ
availableȱinȱfutureȱ
versionsȱofȱAgility).ȱȱ
Codes:ȱ
x 1ȱengineerȱcodeȱ
x 1ȱsubȱengineerȱcodeȱ
x 1ȱgrandȱmasterȱcodeȱ
x 32ȱuserȱcodesȱ
x 4ȱauthorityȱlevelȱ
x Optionalȱ4ȱorȱ6ȱdigitsȱ
codeȱdefinitionȱ
HomeȱAutomationȱ
x 4ȱoutputsȱviaȱwirelessȱI/Oȱ
expanderȱ
x 16ȱXȬ10ȱoutputsȱviaȱ
wirelessȱI/Oȱexpanderȱ
x Outputsȱcanȱfollowȱsystemȱ
,ȱpartition,ȱzoneȱorȱuserȱ
eventsȱ
x Outputsȱcanȱbeȱ
scheduled,ȱorȱactivatedȱ
automatically,ȱorȱbyȱuserȱ
commandȱ(SMS,ȱwebȱ
browserȱorȱremoteȱphone)ȱ
ȱ
FollowȱMe:ȱ
x 16ȱfollowȱmeȱ
destinationsȱ
x Followȱmeȱcanȱbeȱ
definedȱasȱvoiceȱ
message,ȱSMSȱorȱ
Emailȱ
x Userȱcontrolȱoverȱtheȱ
systemȱ
x Securityȱcodeȱ
protectionȱȱȱ
ȱ
Voiceȱcapabilities:ȱ
x 2ȬWayȱcommunicationȱ
x Remoteȱphoneȱoperationȱ
x Fullȱvoiceȱmenuȱguideȱ
x Systemȱeventȱmessagingȱ
x Localȱannouncementȱ
messagesȱ
x Voiceȱdescriptionȱforȱ
zones,ȱpartitions,ȱetc.ȱȱ
WirelessȱFeatures:ȱ
x Signalȱjammingȱ
indicationȱ
x Receiverȱcalibrationȱ
x 868MHz/433ȱMHzȱradioȱ
frequenciesȱ
x Programmableȱ
supervisionȱtimeȱ
x Tamperȱdetectionȱinȱ
transmittersȱ
x Lowȱbatteryȱdetectionȱinȱ
transmittersȱ
Page 1-3
FalseȱCodeȱReduction:ȱ
x Swingerȱshutdownȱ
x Zoneȱcrossingȱȱ
x ReportȱdelayȱtoȱARCȱ
x Abortȱalarmȱfeatureȱ
x Soakȱtestȱ
x Finalȱexitȱzoneȱ
AgilityȱEngineerȱManualȱ
ȱ
Technical Specifications
TheȱfollowingȱtechnicalȱspecificationsȱareȱapplicableȱforȱtheȱAgility:ȱ
Electrical Characteristics
Powerȱ
230VACȱ(Ȭ15%+10%),ȱ50Hz,ȱ50mAȱ
Unitsȱconsumptionsȱȱ
ȱ
Mainȱboard:ȱTypicalȱ130mAȱ
GSM:ȱStandȱbyȱ35mA,ȱCommunicationȱ300mAȱ
Modem:ȱStandȱbyȱ20mA,ȱCommunicationȱ60mAȱȱ
IPȱCard:ȱ90mAȱ(Max)ȱ
Backupȱbatteryȱ
SealedȱLeadȱAcidȱBatteryȱ6Vȱ3.2ȱAhȱ
InternalȱSounderȱintensityȱ 90ȱdBAȱ@1mȱ
Operatingȱtemperatureȱ
Ȭ10°Cȱtoȱ40°Cȱ(14°Fȱtoȱ131°F)ȱ
Storageȱtemperatureȱ
Ȭ20°Cȱtoȱ60°Cȱ(Ȭ4°Fȱtoȱ140°F)ȱ
Physical Characteristics
Dimensionȱ
268.5ȱmmȱxȱ219.5ȱmmȱxȱ64ȱcmȱ(10.57ȱxȱ8.64ȱxȱ2.52ȱinch)ȱ
Weightȱ(noȱbattery)ȱ
1.31Kgȱ(Fullȱconfiguration)ȱ
GSMȱmodule:ȱ0.045ȱKgȱ
Wireless Characteristics
RadioȱImmunityȱ
AccordingȱtoȱENȱ50130Ȭ4ȱ
Frequencyȱ
868.65ȱMHz/433.92ȱMHzȱ
ȱ
Page 1-4
AgilityȱEngineerȱManualȱȱ
ȱ
Chapter 2 Installing the Agility
ThisȱchapterȱcoversȱtheȱinstallationȱproceduresȱofȱtheȱAgility,ȱasȱfollows:ȱȱ
AgilityȱMainȱComponents,ȱpageȱ2Ȭ1ȱ
MountingȱtheȱAgility,ȱpageȱ2Ȭ2ȱ
Choosingȱtheȱmountingȱlocation,ȱpageȱ2Ȭ2ȱ
WallȱMountingȱtheȱAgilityȱpageȱ2Ȭ2ȱ
ConnectingȱtheȱBackupȱBattery,ȱpageȱ2Ȭ5ȱ
ConnectingȱtheȱAgilityȱtoȱPowerȱSupply,ȱpageȱ2Ȭ6ȱ
GroundȱConnection,ȱpageȱ2Ȭ6ȱ
DIPȱswitchȱsetting,ȱpageȱ2Ȭ8ȱ
ConnectingȱaȱȱtelephoneȱlineȱtoȱtheȱAgility,ȱpageȱ2Ȭ9ȱ
SIMȱCardȱInstallation,ȱpageȱ2Ȭ9ȱ
ExternalȱAudioȱUnit,ȱpageȱ2Ȭ12ȱ
Agility Main Components
Theȱillustrationȱbelowȱshowsȱtheȱinternalȱcomponentsȱ(whenȱtheȱMountingȱBracketȱisȱ
disassembledȱfromȱtheȱBackȱPanel).ȱ
8
3
3
9
OPEN
2
LOCK
2
10
11
4
18
ON
1
2
3
4
4
1
1
12
5
17
13
6
7
14
5
16
ȱ
ConfigurationȱAȱ
15
ConfigurationȱBȱ
ȱ
ȱ
Figureȱ1:ȱAgilityȱMainȱComponentsȱ
1.ȱ InstallationȱBracketȱ
7.ȱ Transformerȱ
13ȱ RSȱ232ȱcommunicationȱconnectorȱ
2.ȱ TelephoneȱJacksȱ
8.ȱ BackȱPanelȱ
14. Batteryȱcompartmentȱ
3.ȱ AudioȱUnitȱterminalsȱ
9.ȱ SIMȱCardȱsocketȱ
15. Batteryȱcompartmentȱcoverȱ
4.ȱ Ribbonȱflatȱcableȱjackȱ
10.ȱ Ribbonȱflatȱȱcableȱ
16. Batteryȱflingȱleadsȱ
5.ȱ ACȱconnectionȱterminals/DCȱSocketȱ 11.ȱ DIPȱSwitchesȱ
17. Tamperȱswitchȱ
6.ȱ Fuseȱȱ
18. IPȱCardȱnetworkȱconnectorȱ
12ȱ PTMȱconnectorȱ
Page 2-1
ȱ
AgilityȱEngineerȱManualȱ
Mounting the Agility
IMPORTANT:ȱTheȱAgilityȱhasȱnoȱuserȱreplaceableȱpartsȱ(forȱinstance:ȱpowerȱcord,ȱfuse,ȱbattery,ȱetc.)ȱ
onlyȱcertifiedȱengineersȱareȱallowedȱtoȱreplaceȱfaultyȱparts.ȱȱȱ
Choosing the mounting location
BeforeȱyouȱmountȱtheȱAgility,ȱstudyȱtheȱpremisesȱcarefullyȱinȱorderȱtoȱchooseȱtheȱexactȱ
locationȱofȱtheȱunitȱforȱtheȱbestȱpossibleȱcoverageȱandȱyetȱeasilyȱaccessibleȱtoȱprospectiveȱ
usersȱofȱtheȱalarmȱsystem.ȱȱ
TheȱmountingȱlocationȱofȱtheȱAgilityȱshouldȱbe:ȱ
Tryȱtoȱcentrallyȱlocateȱtheȱsystemȱbetweenȱallȱtheȱtransmitters.ȱ
NearȱanȱuninterruptedȱACȱoutlet.ȱȱȱ
Nearȱaȱtelephoneȱoutlet.ȱ
Farȱfromȱsourcesȱofȱinterference,ȱsuchȱas:ȱ
™
™
™
Directȱheatȱsourcesȱ
Electricalȱnoiseȱsuchȱasȱcomputers,ȱtelevisionsȱetc.ȱ
Largeȱmetalȱobjects,ȱwhichȱmayȱshieldȱtheȱantenna.ȱȱ
InȱaȱplaceȱwhereȱtheȱalarmȱcanȱbeȱheardȱduringȱPartȱSettingȱmode.ȱ
Wall Mounting the Agility
TheȱAgilityȱisȱcomprisedȱofȱtwoȱsubȬassemblies:ȱ
Mountingȱbracket,ȱ
Mainȱunitȱwhichȱinȱitsȱturnȱisȱcomprisedȱfrom:ȱȱ
™
™
Frontȱpanelȱ(notȱdisassembledȱonȱaȱregularȱinstallationȱprocedure)ȱ
Backȱpanelȱ
Theȱmountingȱbracketȱisȱmountedȱonȱtheȱwall,ȱusingȱtheȱsuppliedȱproperȱhardware,ȱasȱ
describedȱbelow:ȱ
ToȱmountȱtheȱAgilityȱonȱtheȱWall:ȱ
1.
SeparateȱtheȱMountingȱbracketȱasȱfollows:ȱ
a. ReleaseȱtheȱMountingȱbracketȱcaptiveȱlockingȱscrewsȱ(1,ȱFigureȱ2)ȱlocatedȱatȱtheȱ
bottomȱofȱtheȱunitȱbyȱturningȱscrewsȱcounterclockwise.ȱȱ
1
ȱ
Figureȱ2:ȱMountingȱBracketȱscrewsȱ
Page 2-2
AgilityȱEngineerȱManualȱȱ
ȱ
b. Gently,ȱpullȱupȱtheȱMountingȱbracketȱtoȱaȱ45°ȱangleȱandȱslideȱitȱdownȱtoȱreleaseȱ
theȱMountingȱbracketȱ(2,ȱFigureȱ3)ȱfromȱtheȱtwoȱlockingȱtabsȱ(1,ȱFigureȱ3)ȱatȱtheȱ
topȱofȱtheȱunit.ȱȱ
Note:ȱDoȱnotȱopenȱtheȱMountingȱbracketȱtoȱaȱlargerȱangleȱinȱorderȱnotȱtoȱbreakȱtheȱtwoȱtopȱtabsȱandȱnotȱtoȱ
tearȱupȱtheȱribbonȱflatȱcableȱconnectingȱtheȱpowerȱsupplyȱunitȱtoȱtheȱfrontȱpanelȱ(PCB).ȱȱ
c.
Disconnectȱtheȱribbonȱflatȱcableȱ(3)ȱfromȱtheȱpowerȱsupplyȱunitȱwhileȱleavingȱitȱ
connectedȱtoȱtheȱMainȱpanel.ȱ
ȱ
Figureȱ3:ȱMountingȱBracketȱremovalȱ
2.
HoldȱtheȱMountingȱbracketȱagainstȱtheȱwallȱasȱaȱtemplateȱandȱmarkȱtheȱlocationsȱforȱ
theȱmountingȱholesȱ(5ȱmountingȱholesȱitemȱ1,ȱandȱanȱadditionalȱholeȱforȱsecuringȱtheȱ
tamperȱprotectionȱbracketȱitemȱ2,ȱareȱavailable,ȱseeȱFigureȱ4).ȱȱ
3.
Drillȱtheȱdesiredȱmountingȱholesȱandȱplaceȱtheȱscrewȱanchors.ȱUseȱtheȱsuppliedȱ5ȱ
PhilipsȱpanȱheadȱscrewsȱtoȱattachȱtheȱMountingȱbracketȱtoȱtheȱwallȱ(ST4.2ȱmmȱxȱ32ȱ
mmȱDINȱ7981).ȱ
4.
Accordingȱtoȱtheȱlocationȱofȱtheȱwallȱcables,ȱrouteȱandȱinsertȱtheȱwiresȱandȱcablesȱviaȱ
theȱcable’sȱopeningsȱ(3)ȱ(includingȱACȱcableȱandȱtelephoneȱcable),ȱseeȱfigureȱ3.ȱ
5.
Ifȱrequired,ȱremoveȱcableȱknockoutsȱ(5)ȱtoȱallowȱwireȱpassage.ȱȱ
6.
Anchorȱcablesȱwithȱdedicatedȱhooksȱ(4).ȱȱ
Page 2-3
ȱ
AgilityȱEngineerȱManualȱ
1
1
4
4
3
3
3
2
3
2
1
1
ȱ
ConfigurationȱAȱ
ȱ
ConfigurationȱBȱ
5
6
7
ȱ
Figureȱ4:ȱWallȱInstallationȱ
7.
AdjustȱtheȱTamperȱswitchȱ(usingȱaȱflatȱscrewdriver)ȱaccordingȱtoȱyourȱpreferredȱ
configuration.ȱ
a. BoxȱandȱWallȱconfigurationȱ(seeȱFigureȱ4,ȱdetailȱ6)ȱȬȱTriggersȱtheȱtamperȱwhenȱtheȱ
boxȱorȱtheȱwallȱmountingȱareȱtampered.ȱȱ
b. Boxȱonlyȱconfigurationȱ(seeȱFigureȱ4,ȱdetailȱ7)ȱ–ȱTriggersȱtheȱtamperȱwhenȱtheȱboxȱ
isȱtampered.ȱ
Page 2-4
AgilityȱEngineerȱManualȱȱ
ȱ
Connecting the Backup Battery
TheȱAgilityȱhasȱsafetyȱapproved,ȱsealedȱleadȱacidȱ6V,ȱ3.2ȱAhȱrechargeableȱbackupȱbatteryȱ
usedȱinȱtimeȱofȱmainȱpowerȱfailure:ȱ
Note:ȱTheȱbatteryȱisȱsuppliedȱwithȱtheȱAgility.ȱ
ToȱinsertȱtheȱBackupȱbattery:ȱ
Removeȱtheȱbatteryȱcompartmentȱcoverȱscrewȱ(seeȱFigureȱ5,3)ȱlocatedȱatȱtheȱtopȱofȱtheȱ
coverȱbyȱturningȱscrewȱcounterclockwiseȱandȱpullȱtheȱAgilityȱbatteryȱcoverȱoutward.ȱȱ
1
2
3
2
ȱ
Figureȱ5:ȱBatteryȱCompartmentȱ
a.ȱInsertȱtheȱbatteryȱintoȱitsȱplaceȱandȱconnectȱtheȱflyingȱleadsȱtoȱtheȱbatteryȱ
accordingȱtoȱtheȱcorrectȱpolarityȱ(Redȱ+)ȱ(BlackȱȬ).ȱ
b.ȱReturnȱtheȱbatteryȱcompartmentȱcoverȱ(afterȱplacingȱtheȱbatteryȱin)ȱandȱsecureȱ
withȱlockingȱscrew.ȱ
Note:ȱTheȱAgilityȱRechargeableȱbatteryȱshouldȱbeȱchargedȱforȱatȱleastȱ24ȱhours.ȱȱ
ȱ
Important:ȱȱWhenȱreplacingȱtheȱbatteryȱbeȱsureȱtoȱbuyȱtheȱsameȱtype.ȱFailureȱtoȱcomplyȱwithȱthisȱinstructionȱ
mayȱresultȱinȱdamageȱtoȱpersonnelȱand/orȱequipment.ȱ
ȱ
ȱDisposeȱofȱusedȱbatteriesȱaccordingȱtoȱtheȱproperȱinstructions.ȱ
Page 2-5
ȱ
AgilityȱEngineerȱManualȱ
Connecting the Agility to Power Supply - Configuration A
Note:ȱTheȱAgilityȱpanelȱisȱpermanentlyȱconnectedȱtoȱtheȱmains.ȱTheȱconnectionȱmustȱbeȱmadeȱaccordingȱtoȱ
yourȱcountryȇsȱlocalȱregulations.ȱAsȱaȱgeneralȱguideline,ȱconnectȱtheȱLiveȱNeutralȱandȱGroundȱusingȱaȱ
safetyȱapprovedȱ3Ȭwireȱ18AWGȱpowerȱcableȱ(14ȬmmȱminimumȱdiameterȱflexibleȱPVCȱcableȱwhichȱ
compliesȱwithȱIEC60227).ȱTheȱcableȱshouldȱbeȱbroughtȱtoȱtheȱAgilityȱpanelȱinȱaȱprotectiveȱplasticȱ
conduitȱ(diameterȱȬȱ16mmȱminimum).ȱ
ȱ
Aȱ2Ȭpoleȱ16Aȱcircuitȱbreakerȱandȱearthȱleakageȱprotectorȱshouldȱbeȱusedȱtoȱdisconnectȱtheȱliveȱ
conductor,ȱandȱshouldȱbeȱprovidedȱasȱpartȱofȱtheȱbuildingȱinstallation.ȱ
TheȱAgilityȱisȱpoweredȱbyȱaȱsafetyȱapprovedȱ230VAC.ȱȱ
1.ȱȱRemoveȱtheȱpowerȱsupplyȱunitȱcoverȱ(Figureȱ6,ȱ1).ȱ
2.ȱȱConnectȱtheȱpowerȱwireȱ(Safetyȱapproved,ȱSVT,ȱ18AWG,ȱ0.75mm2)ȱtoȱtheȱȱȱ
ȱpowerȱterminalȱlocatedȱonȱtheȱpowerȱsupplyȱunitȱ(TB1)ȱ(2,ȱFigureȱ6).ȱȱ
Note:ȱTheȱpowerȱwireȱisȱnotȱsuppliedȱwithȱtheȱAgility.ȱ
3.ȱȱDOȱNOTȱconnectȱtheȱcableȱtoȱtheȱwallȱpowerȱsupplyȱatȱthisȱpoint.ȱ
Ground Connection
Groundingȱprovidesȱaȱdegreeȱofȱprotectionȱagainstȱlightningȱandȱinducedȱtransientsȱforȱ
anyȱpieceȱofȱelectronicȱequipmentȱthatȱmay,ȱdueȱtoȱlightningȱorȱstaticȱdischarge,ȱ
experienceȱpermanentȱorȱgeneralȱmalfunctions.ȱTheȱidealȱgroundȱisȱconsideredȱtoȱbeȱaȱ
unifiedȱearthȱgroundȱinȱwhichȱanȱ8ȬfootȱcopperȬcladȱrod,ȱlocatedȱcloseȱtoȱtheȱexistingȱ
powerȱandȱtelephoneȱgroundȱrods,ȱisȱsunkȱseveralȱfeetȱintoȱtheȱearth.ȱAppropriateȱ
hardwareȱandȱclampsȱareȱthenȱusedȱtoȱelectricallyȱconnectȱeachȱofȱtheseȱrodsȱtogetherȱandȱ
thenȱtoȱtheȱgroundȱterminalȱofȱtheȱdeviceȱtoȱbeȱprotected.ȱȱ
Itȱmayȱbeȱpossibleȱtoȱuseȱanȱexistingȱelectricalȱgroundȱonȱtheȱpremisesȱifȱoneȱisȱcloseȱ
enoughȱtoȱtheȱAgility.ȱWhenȱconnectingȱtheȱgroundȱwire,ȱuseȱaȱsolidȱ14Ȭgaugeȱwireȱ[orȱ
largerȱ(numericallyȱlower)ȱsize].ȱKeepȱthisȱwireȱasȱshortȱasȱpossibleȱandȱdoȱnotȱrunȱitȱinȱ
conduit,ȱcoilȱit,ȱbendȱitȱsharply,ȱorȱrunȱitȱalongsideȱotherȱwiring.ȱIfȱyouȱmustȱbendȱitȱorȱ
changeȱitsȱdirection,ȱitȱshouldȱhaveȱaȱradiusȱofȱatȱleastȱ8ȱinchesȱatȱtheȱpointȱfromȱwhichȱitȱ
isȱbent.ȱȱIfȱinȱdoubt,ȱyouȱmayȱwantȱtoȱenlistȱtheȱhelpȱofȱaȱlicensedȱelectricianȱinȱmattersȱ
concerningȱsuchȱgrounding.ȱ
ȱ
Toȱconnectȱtoȱgroundȱ(Earth):ȱ
ConnectȱbetweenȱtheȱAgility’sȱgroundȱterminalȱandȱanȱacceptableȱelectricalȱgroundȱ
connectionȱforȱtheȱlightningȱtransientȱprotectiveȱdevicesȱinȱthisȱproductȱtoȱbeȱeffective.ȱȱȱ
Important:ȱConnectingȱtoȱgroundȱmustȱbeȱperformedȱaccordingȱtoȱtheȱlocalȱNationalȱElectricalȱCode.ȱ
Page 2-6
AgilityȱEngineerȱManualȱȱ
ȱ
2
~
TB1
1
ȱ
Figureȱ6:ȱConnectingȱACȱPowerȱwiresȱ
Connecting the Agility to Power Supply - Configuration B
1.
TheȱAgilityȱisȱpoweredȱbyȱaȱ9VDC/1.0AȱTransformer.ȱ
2.
Connectȱtheȱtransformerȱpowerȱjackȱtoȱtheȱpowerȱsupplyȱlocatedȱonȱtheȱ
powerȱsupplyȱcardȱ(1,ȱFigureȱ6A).ȱȱ
3.
DOȱNOTȱconnectȱtheȱtransformerȱinletȱcableȱtoȱtheȱwallȱpowerȱsupplyȱatȱ
thisȱpoint.ȱ
From 9VDC/1.0A
Transformer
1
2
Figureȱ6A:ȱConnectingȱDCȱPowerȱCableȱ
Page 2-7
ȱ
AgilityȱEngineerȱManualȱ
Completing Installation
1.ȱȱSetȱtheȱDIPȱSwitchesȱaccordingȱtoȱtheȱDIPȱSwitchȱSettingȱsectionȱ(seeȱpageȱ2Ȭ8).ȱ
2.ȱȱConnectȱtheȱribbonȱflatȱcableȱbetweenȱtheȱmainȱpanelȱandȱtheȱmountingȱbracketȱ(J1).ȱȱȱ
3.ȱȱMountȱtheȱMainȱunitȱtoȱtheȱmountingȱbracketȱusingȱcaptiveȱlockingȱscrews.ȱ
4.ȱȱPlugȱinȱtheȱpowerȱcableȱtoȱtheȱwallȱpowerȱoutlet.ȱ
5.ȱȱPowerȱupȱtheȱAgility.ȱ
DIP switch setting
ON
Factory
Default
ȱ
DIPȱSwitchȱ1ȱ(EȬA):ȱExternalȱAudio:ȱUsedȱtoȱdefineȱifȱtheȱvoiceȱofȱtheȱAgilityȱwillȱgoȱfromȱ
theȱmainȱunitȱorȱfromȱanȱExternalȱAudioȱUnit.ȱWhenȱtheȱexternalȱunitȱisȱconnectedȱtoȱtheȱ
AgilityȱtheȱvoiceȱwillȱbeȱheardȱonlyȱthroughȱtheȱAudioȱvoiceȱunit.ȱ
ON:ȱExternalȱAudioȱUnitȱisȱconnectedȱtoȱtheȱAgilityȱȱ
OFFȱ(Default):ȱExternalȱAudioȱunitȱnotȱconnectedȱtoȱtheȱAgility.ȱ
DIPȱSwitchȱ2ȱ(DFLT):ȱDefaultȱjumper:ȱUsedȱwhenȱperformingȱtheȱfollowingȱ3ȱoperations:ȱ
1.ȱToȱreturnȱengineer,ȱsubȬengineerȱandȱgrandȱmasterȱcodesȱtoȱtheirȱdefaultȱfactoryȱ
values.ȱSetȱthisȱDIPȱswitchȱtoȱON,ȱdisconnectȱallȱpowerȱandȱthenȱreconnectȱtheȱpower.ȱ
1
2
3
4
Note:ȱCodeȱLengthȱdoesȱnotȱchange.ȱ
2.ȱToȱmanuallyȱeraseȱwirelessȱdevices.ȱSetȱthisȱDIPȱswitchȱtoȱONȱwhileȱpowerȱisȱ
connected.ȱExecuteȱaȱlongȱpressȱonȱtheȱmainȱunitȱbuttonȱuntilȱaȱbeep,ȱindicatingȱthatȱallȱ
wirelessȱdevicesȱhaveȱbeenȱerased,ȱisȱheard.ȱ
3.ȱToȱsaveȱorȱtransferȱdataȱtoȱorȱfromȱtheȱPTMȱdevice.ȱȱ
ON:ȱToȱtransferȱdataȱfromȱtheȱPTMȱtoȱtheȱpanel.ȱȱ
OFF:ȱToȱtransferȱdataȱfromȱtheȱpanelȱtoȱtheȱPTM.ȱ(ReferȱtoȱChapterȱ3ȱforȱtheseȱprocedures.)ȱ
DIPȱSwitchȱ3ȱ(PRGM):ȱȱEnablesȱloadingȱlocalȱsoftwareȱupdatesȱtoȱtheȱAgilityȱ
ON:ȱsoftwareȱupdatesȱtoȱtheȱAgilityȱcanȱbeȱloadedȱ
OFFȱ(Default):ȱsoftwareȱupdatesȱtoȱtheȱAgilityȱcanȱnotȱbeȱloadedȱ
DIPȱSwitchȱ4ȱ(BAT):ȱDefinesȱtheȱBatteryȱDischargeȱProtectionȱoptionȱsettingsȱ
ȱ ON:ȱBatteryȱDischargeȱProtectionȱisȱOFF:ȱTheȱbatteryȱmayȱbeȱtotallyȱdischargedȱduringȱ
continuousȱACȱfailure,ȱthusȱbatteryȱreplacementȱmayȱbeȱrequiredȱ(noȱdeepȱdischargeȱ
protection).ȱ
Note:ȱȱInȱthisȱpositionȱtheȱAgilityȱwillȱstartȱtoȱoperateȱfromȱaȱbatteryȱpowerȱsupplyȱwhetherȱitȱisȱconnectedȱ
toȱtheȱMainsȱorȱnot.ȱ
ȱ OFFȱ(Default):ȱBatteryȱdeepȱDischargeȱProtectionȱisȱON:ȱIfȱanȱACȱpowerȱoutageȱoccurs,ȱ
theȱAgilityȱautomaticallyȱdisconnectsȱtheȱbatteryȱwhenȱitsȱbackupȱbatteryȱvoltageȱdropsȱ
belowȱ5.8ȱVDC,ȱinȱorderȱtoȱpreventȱȈdeepȱdischarge”ȱthatȱmayȱdamageȱtheȱbattery.ȱ
Note:ȱȱInȱthisȱpositionȱtheȱAgilityȱwillȱnotȱstartȱtoȱoperateȱfromȱaȱbatteryȱpowerȱsupply,ȱunlessȱ
connectedȱtoȱtheȱMainsȱfirst.ȱ
Page 2-8
AgilityȱEngineerȱManualȱȱ
ȱ
Connecting a telephone line to the Agility
Connectȱtheȱsystemȱtoȱaȱtelephoneȱlineȱifȱtheȱsystemȱconfigurationȱincludesȱanȱinternalȱ
modemȱ(identicalȱforȱConfigurationȱAȱandȱB).ȱ
1. ConnectȱtheȱincomingȱtelephoneȱlineȱtoȱtheȱplugȬinȱCONN2ȱjackȱRJ11ȱ(pinsȱ2,ȱ3)ȱorȱtoȱ
plugȬinȱCONN3ȱRJ31ȱ(pinsȱ4,ȱ5)ȱ(seeȱFigureȱ7:ȱTelephoneȱLineȱJacks).ȱ
2.
ConnectȱanyȱtelephoneȱonȱtheȱpremisesȱtoȱtheȱplugȬinȱCONN2ȱȱjackȱRJ11ȱ
(pinsȱ1,ȱ4)ȱorȱtoȱplugȬinȱCONN3ȱRJ31ȱ(pinsȱ1,ȱ8)ȱ(seeȱFigureȱ7:ȱTelephoneȱ
LineȱJacks).ȱ
NOTE:ȱToȱensureȱlineȱseizureȱcapability,ȱandȱcomplyȱwithȱFCCȱpartȱ68ȱregulations,ȱtheȱequipmentȱmustȱbeȱ
connectedȱdirectlyȱtoȱtheȱPhoneȱcompanyȱlinesȱ(ȇCOȇ).ȱWhetherȱconnectedȱviaȱRJ11,ȱRJ31,ȱtheȱlineȱ
portȱmustȱbeȱconnectedȱtoȱtheȱCOȱlinesȱwithoutȱanyȱotherȱphonesȱorȱotherȱtelecomȱequipmentȱ
betweenȱthem.ȱOtherȱtelecomȱequipmentȱcanȱbeȱconnectedȱonlyȱafterȱ(inȱseries)ȱtheȱalarmȱpanel.ȱȱ
CONN2
RJ11
CONN3
RJ31
ȱ
Figureȱ7:ȱTelephoneȱLineȱJacksȱ
Page 2-9
ȱ
AgilityȱEngineerȱManualȱ
Connecting a network cable to the Agility
IfȱyourȱAgilityȱisȱequippedȱwithȱanȱIPȱCard,ȱyouȱshouldȱconnectȱtheȱincomingȱnetworkȱ
cableȱinȱorderȱtoȱenableȱIPȱCommunication.ȱ
1.ȱȱSeparateȱtheȱAgilityȱfromȱtheȱmountingȱbracket.ȱȱȱ
2.ȱȱAccordingȱtoȱtheȱlocationȱofȱtheȱnetworkȱcable,ȱrouteȱandȱinsertȱtheȱcableȱviaȱtheȱcable’sȱȱȱ
openingsȱ(seeȱfigureȱ3).ȱ
3.ȱȱIfȱrequired,ȱremoveȱcableȱknockoutsȱ(5,ȱFigureȱ3)ȱtoȱallowȱcableȱpassage.ȱȱ
4.ȱȱConnectȱtheȱincomingȱnetworkȱcableȱtoȱtheȱplugȬin.ȱ
ȱ
Page 2-10
AgilityȱEngineerȱManualȱȱ
ȱ
SIM Card Installation
IfȱyourȱAgilityȱisȱequippedȱwithȱaȱGSM/GPRSȱmodule,ȱyouȱshouldȱinsertȱaȱSIMȱcardȱinȱ
orderȱtoȱenableȱcommunicationȱthroughȱtheȱGSM/GPRSȱnetwork.ȱ
1. InsertȱtheȱSIMȱintoȱtheȱdedicatedȱSIMȱcardȱslotȱlocatedȱonȱtheȱrearȱsideȱofȱtheȱbackȱpanelȱ
(SeeȱFigureȱ1:ȱAgilityȱMainȱComponents).ȱȱ
LOCK
LOCK
1. Slide down SIM
card hatch .
2. Open the SIM card
hatch. Insert SIM card
into dedicated slot.
OPEN
OPEN
OPEN
LOCK
SIM Card
3. Close the SIM card
hatch . Slide up to lock.
ȱ
Figureȱ8:ȱȱSIMȱCardȱInsertionȱ
ȱ
Important:ȱDoȱnotȱinstallȱSIMȱcardȱwhileȱpowerȱisȱappliedȱtoȱtheȱAgility.ȱȱȱ
ȱ
ȱ
DoȱnotȱtouchȱSIMȱCardȱconnectors!ȱIfȱdoingȱso,ȱyouȱmayȱreleaseȱanȱelectricalȱdischargeȱthatȱcouldȱ
ȱ
damageȱtheȱSIMȱcard.ȱ
2. IfȱaȱPINȱcodeȱisȱrequiredȱforȱtheȱSIMȱcard,ȱtheȱAgilityȱwillȱindicateȱaȱPINȱcodeȱfault.ȱ
Toȱfixȱtheȱfault,ȱandȱthusȱenableȱtheȱSIMȱcardȱtoȱoperateȱproperly,ȱenterȱtheȱPINȱcodeȱ
number,ȱlocatedȱinȱtheȱCommunicationȱ>ȱGSMȱparametersȱmenu.ȱȱ
Note:ȱEnsureȱthatȱyouȱhaveȱtheȱPINȱcode.ȱBeȱawareȱthatȱafterȱthreeȱwrongȱattemptsȱ(recognizedȱbyȱtheȱSIMȱ
card)ȱtoȱenterȱaȱPINȱnumber,ȱtheȱSIMȱcardȱwillȱlock.ȱȱ
ȱ
YouȱwillȱhaveȱtoȱcontactȱyourȱlocalȱcellularȱproviderȱtoȱunlockȱtheȱSIMȱcard.ȱ
3. IfȱyouȱwantȱtoȱdisableȱtheȱSIMȱPINȱcodeȱyouȱshouldȱfollowȱtheȱsteps:ȱ
a. InsertȱtheȱSIMȱcardȱintoȱaȱstandardȱGSMȱmobileȱphone.ȱȱ
b. InsertȱtheȱPINȱcode.ȱ
c. AccessȱtheȱphoneȱsecurityȱmenuȱandȱselectingȱPINȱOFF.ȱOnceȱdone,ȱreȬtestȱbyȱ
switchingȱtheȱphoneȱOFF,ȱthenȱswitchingȱON.ȱTheȱPINȱcodeȱshouldȱnotȱbeȱrequestedȱ
again.ȱ
4. OnceȱtheȱSIMȱcardȱisȱplacedȱitȱisȱrecommendedȱtoȱtestȱtheȱoperationȱofȱtheȱSIMȱbyȱ
conductingȱaȱcallȱandȱtestingȱtheȱGSMȱsignalȱstrength.ȱForȱmoreȱinformationȱreferȱtoȱtheȱ
programmingȱmenusȱofȱtheȱGSMȱmenu.ȱȱ
Note:ȱInȱsomeȱcountriesȱanȱSMSȱcenterȱphoneȱnumberȱmightȱbeȱrequiredȱinȱorderȱtoȱenableȱSMSȱmessaging.ȱ
Thisȱphoneȱnumberȱisȱprovidedȱbyȱtheȱprovider.ȱProgrammingȱtheȱSMSȱcenterȱphoneȱintoȱtheȱSIMȱcanȱ
beȱdoneȱusingȱaȱstandardȱGSMȱmobileȱphoneȱorȱfromȱtheȱAgilityȱkeypadȱorȱconfigurationȱsoftware.ȱ
Page 2-11
ȱ
AgilityȱEngineerȱManualȱ
External Audio Unit
TheȱAgilityȱenablesȱtoȱconnectȱanȱexternalȱAudioȱUnitȱinsteadȱofȱtheȱinternalȱunitȱinȱorderȱ
toȱlistenȱtoȱtheȱsystemȇsȱaudioȱmessagesȱinȱaȱdistanceȱfromȱtheȱmainȱunit.ȱInȱadditionȱtheȱ
unitȱenablesȱyouȱtoȱtalkȱintoȱyourȱpremises.ȱȱȱ
ToȱconnectȱtheȱAudioȱunit:ȱȱ
1. WireȱtheȱAudioȱunitȱtoȱtheȱAgilityȱasȱdisplayedȱinȱtheȱWiringȱDiagramȱdescribedȱ
inȱFigureȱ9.ȱTheȱterminalsȱforȱwiringȱtheȱAudioȱUnitȱtoȱtheȱAgilityȱareȱlocatedȱonȱ
mountingȱbracketȱtheȱAgility.ȱ
2. SetȱDIPȱSwitchȱ1ȱ(EȬȱA)ȱ(ExternalȱAudio)ȱtoȱOnȱposition.ȱȱȱȱȱ
ȱ
Figureȱ9:ȱȱWiringȱtheȱExternalȱAudioȱUnitȱȱtoȱAgilityȱȱ
ȱ
ȱ
Page 2-12
AgilityȱEngineerȱManualȱȱ
ȱ
Chapter 3 Engineer Programming
Programming Methods
Thereȱareȱ4ȱavailableȱoptionsȱforȱprogrammingȱtheȱAgility:ȱ
ConfigurationȱSoftwareȱ
WirelessȱKeypadȱ
EngineerȱKeypadȱ
PTMȱ
Configuration Software
AȱsoftwareȱapplicationȱthatȱenablesȱyouȱtoȱprogramȱtheȱAgilityȱfromȱaȱPCȱcomputer.ȱItȱ
offersȱtheȱfollowingȱalternatives:ȱ
Workingȱlocally,ȱthroughȱaȱportableȱcomputerȱconnectedȱtoȱtheȱAgilityȱviaȱcableȱ
Workingȱatȱaȱremoteȱsite,ȱcommunicatingȱwithȱtheȱAgilityȱviaȱaȱphoneȱline,ȱ
modemȱorȱIPȱaddress.ȱ
ForȱfurtherȱinformationȱonȱprogrammingȱtheȱAgilityȱviaȱtheȱConfigurationȱsoftware,ȱreferȱ
toȱtheȱAgilityȱConfigurationȱSoftwareȱmanual.ȱ
Wireless Keypad
TheȱAgilityȱcanȱbeȱfullyȱconfiguredȱviaȱtheȱwirelessȱkeypad.ȱ
Notes:ȱȱ
1.ȱTheȱAgilityȱcanȱbeȱprogrammedȱviaȱanyȱofȱtheȱ2ȱwayȱkeypadsȱinȱyourȱsystem,ȱbutȱonlyȱusingȱoneȱ
keypadȱatȱaȱtimeȱforȱprogramming.ȱȱ
2.ȱDuringȱengineerȱprogramming,ȱtheȱkeypadȱwillȱturnȱoffȱafterȱ4ȱminutesȱifȱnoȱentryȱhasȱbeenȱmadeȱ
toȱtheȱkeys.ȱPressȱanyȱbuttonȱtoȱrestoreȱtheȱkeypad.ȱItȱwillȱdisplayȱtheȱlastȱparameterȱyouȱwereȱ
workingȱon.ȱ
ȱ
ToȱprogramȱtheȱAgilityȱviaȱtheȱWirelessȱKeypad,ȱfollowȱthisȱprocedure:ȱ
1.
Performȱsystemȱdeviceȱallocationȱforȱtheȱkeypadȱ(referȱtoȱpageȱ3Ȭ4).ȱ
2.
ȱandȱenterȱtheȱengineerȱcodeȱ(defaultȱcodeȱisȱ0132).ȱTheȱkeypadȱwillȱ
Pressȱ
soundȱaȱconfirmationȱsound.ȱ
Note:ȱIfȱaȱGrandȱMasterȱcodeȱisȱrequiredȱtoȱconfirmȱtheȱengineerȱcode,ȱitȱshouldȱbeȱenteredȱatȱthisȱ
stageȱafterȱtheȱengineerȱcode.ȱ
Page 3-1
ȱ
3.
AgilityȱEngineerȱManualȱ
GoȱtoȱtheȱProgrammingȱmenuȱandȱpressȱ
.ȱOnceȱtheȱpanelȱisȱinȱprogrammingȱ
mode,ȱtheȱAgilityȱmainȱunitȱLEDsȱwillȱflashȱsimultaneouslyȱandȱaȱconfirmationȱ
soundȱwillȱbeȱheard.ȱ
Note:ȱTheȱengineerȱcanȱalsoȱprogramȱuserȱactivitiesȱbyȱselectingȱtheȱActivitiesȱmenuȱinsteadȱofȱ
theȱProgrammingȱmenu.ȱUseȱtheȱ
ȱbuttonsȱtoȱnavigateȱbetweenȱtheȱmenus.ȱ
Engineer Keypad
Forȱthoseȱsystemsȱthatȱdoȱnotȱhaveȱkeypads,ȱRISCOȱGroupȱoffersȱtheȱAgilityȱengineerȱaȱ
temporaryȱkeypadȱtoȱbeȱusedȱasȱanyȱAgilityȱwirelessȱkeypadȱforȱconfiguringȱaȱsystem.ȱAnȱ
hourȱafterȱexitingȱtheȱprogrammingȱmodeȱtheȱEngineerȱKeypadȱwillȱbeȱerasedȱfromȱtheȱ
Agilityȱmemoryȱorȱwhenȱpowerȱisȱlostȱtoȱtheȱsystem.ȱȱ
ȱ
ToȱprogramȱtheȱAgilityȱviaȱtheȱEngineerȱKeypad,ȱfollowȱthisȱprocedure:ȱ
1. ToȱallocateȱtheȱEngineerȱKeypadȱintoȱtheȱsystemȱperformȱaȱshortȱpressȱonȱtheȱ
mainȱunitȱbutton.ȱȱ
2.
Pressȱtheȱ
ȱbuttonsȱonȱtheȱkeypadȱsimultaneouslyȱuntilȱtheȱfollowingȱ
messageȱappears:ȱ
ȱ
3.
EnterȱtheȱGrandȱMasterȱcodeȱandȱpressȱ
isȱheard:ȱ“EngineerȱKeypadȱAllocated”.ȱ
.ȱTheȱfollowingȱconfirmationȱmessageȱ
Note:ȱWhenȱaȱwrongȱGrandȱMasterȱcodeȱisȱentered,ȱtheȱkeypadȱwillȱbeȱdeleted.ȱToȱcontinueȱ
thisȱprocedure,ȱperformȱreallocationȱofȱtheȱkeypad.ȱȱ
4.
Followȱstepsȱ2ȱandȱ3ȱofȱtheȱwirelessȱkeypadȱ(seeȱpageȱ3Ȭ1)ȱtoȱbeginȱprogrammingȱ
theȱsystem.ȱ
PTM: Data Storing Device
TheȱPTMȱisȱaȱtinyȱcircuitȱboardȱintoȱwhichȱtheȱAgilityȱpanelȱcanȱtransmitȱaȱcopyȱofȱtheȱ
systemȇsȱconfiguration.ȱTheȱPTMȱstoresȱthisȱcopyȱandȱcanȱalsoȱtransmitȱtheȱconfigurationȱ
informationȱbackȱtoȱtheȱAgilityȱpanel.ȱ
ȱ
ToȱtransferȱtheȱsystemȱconfigurationȱfromȱtheȱpanelȱtoȱtheȱPTM,ȱfollowȱthisȱprocedure:ȱ
1. DisconnectȱtheȱflatȱcableȱandȱremoveȱtheȱAgilityȱmainȱunitȱfromȱitsȱwallȱbracket.ȱ
Note:ȱMakeȱsureȱtheȱbatteryȱisȱinsertedȱintoȱtheȱmainȱunit.ȱ
Page 3-2
AgilityȱEngineerȱManualȱȱ
2.
3.
4.
5.
6.
7.
ȱ
MakeȱsureȱthatȱDipswitchȱ2ȱisȱsetȱtoȱOFFȱ(defaultȱsetting).ȱ
PlaceȱtheȱPTMȱontoȱtheȱ5ȬpinȱPTMȱlocatedȱonȱtheȱrearȱofȱtheȱmainȱunitȱPCB.ȱTheȱ
PTMȱLEDȱwillȱturnȱon.ȱ
Pressȱtheȱmainȱunitȱbuttonȱforȱ5ȱseconds.ȱTheȱPTMȱLEDȱwillȱflashȱquicklyȱduringȱ
theȱtransmissionȱofȱinformationȱtoȱtheȱPTM.ȱ
Onceȱtransmissionȱisȱcomplete,ȱtheȱpanelȱwillȱsoundȱaȱconfirmationȱbeepȱandȱtheȱ
PTMȱLEDȱwillȱstopȱflashingȱandȱturnȱonȱsteady.ȱȱ
DisconnectȱtheȱPTMȱfromȱtheȱmainȱunit.ȱ
Reconnectȱtheȱflatȱcableȱtoȱtheȱmainȱunitȱandȱreplaceȱtheȱmainȱunitȱinȱitsȱwallȱ
bracket.ȱ
ȱȱ
ToȱtransferȱtheȱsystemȱconfigurationȱfromȱtheȱPTMȱtoȱtheȱAgilityȱpanel,ȱfollowȱthisȱ
procedure:ȱ
1. DisconnectȱtheȱflatȱcableȱandȱremoveȱtheȱAgilityȱmainȱunitȱfromȱitsȱwallȱbracket.ȱ
Note:ȱMakeȱsureȱtheȱbatteryȱisȱinsertedȱintoȱtheȱmainȱunit.ȱ
MakeȱsureȱthatȱtheȱDefaultȱEnableȱsystemȱflagȱisȱonȱ
2.
3.
4.
5.
SetȱDipswitchȱ2ȱtoȱON.ȱ
PlaceȱtheȱPTMȱontoȱtheȱ5ȬpinȱPTMȱconnectorȱlocatedȱonȱtheȱmainȱunitȱPCB.ȱ
AllȱLEDSȱonȱtheȱmainȱunitȱwillȱbeginȱtoȱflashȱsimultaneously.ȱTheȱPTMȱLEDȱwillȱ
flashȱquicklyȱduringȱtheȱtransmissionȱofȱinformationȱtoȱtheȱpanel.ȱ
Onceȱtransmissionȱisȱcomplete,ȱtheȱpanelȱwillȱsoundȱaȱconfirmationȱbeep.ȱ
Note:ȱȱIfȱtheȱprocedureȱfailsȱtheȱpanelȱwillȱmakeȱ3ȱshortȱerrorȱbeeps,ȱandȱyouȱwillȱneedȱtoȱdoȱtheȱ
procedureȱagainȱ
6.
7.
8.
DisconnectȱtheȱPTMȱfromȱtheȱmainȱunit.ȱ
ResetȱDipswitchȱ2ȱtoȱOFF.ȱ
Reconnectȱtheȱflatȱcableȱtoȱtheȱmainȱunitȱandȱreplaceȱtheȱmainȱunitȱinȱitsȱwallȱ
bracket.ȱ
Page 3-3
ȱ
AgilityȱEngineerȱManualȱ
Wireless Device Allocation
Eachȱwirelessȱdeviceȱmustȱidentifyȱitselfȱtoȱtheȱsystemȱreceiver.ȱTheȱfollowingȱsectionȱ
describesȱtheȱdifferentȱwaysȱtoȱallocateȱallȱofȱyourȱdevicesȱtoȱtheȱsystemȱinȱorderȱtoȱlaterȱ
configureȱeachȱdeviceȇsȱparametersȱȱ
Theȱlearningȱprocedureȱbetweenȱtheȱwirelessȱdevicesȱandȱtheȱmainȱunitȱcanȱbeȱperformedȱ
eitherȱfromȱtheȱmainȱunit,ȱaȱwirelessȱkeypadȱorȱviaȱtheȱConfigurationȱSoftware.ȱȱ
Quick Allocation using the main unit button
Toȱperformȱquickȱallocationȱusingȱtheȱmainȱunitȱbutton,ȱfollowȱthisȱprocedure:ȱ
Note:ȱToȱenableȱQuickȱAllocationȱmodeȱtheȱSystemȱbitȱȈQuickȱLearnȈȱshouldȱbeȱenabled.ȱ
1.
SetȱtheȱmainȱunitȱtoȱLearnȱmodeȱwithȱaȱlongȱpressȱonȱtheȱmainȱunitȱbutton.ȱEachȱ
LEDȱwillȱlightȱupȱoneȱafterȱanother.ȱ
Note:ȱTheȱunitȱwillȱsoundȱeachȱtimeȱyouȱenterȱorȱexitȱtheȱLearnȱmode.
2.
3.
Sendȱaȱtransmissionȱfromȱeachȱdeviceȱ(referȱtoȱtheȱTransmittersȱwriteȱmessageȱ
methodȱtableȱinȱsection).ȱTheȱsystemȱwillȱautomaticallyȱidentifyȱeachȱdeviceȱ
accordingȱtoȱdifferentȱcategoriesȱ(forȱexample:ȱdetectors,ȱsounders,ȱkeypads,ȱ
remoteȱcontrolsȱetc.)ȱandȱenterȱeachȱdeviceȱandȱitsȱdefaultȱvalueȱintoȱtheȱunitȇsȱ
memory.ȱEachȱdeviceȱreceivesȱanȱindexȱnumberȱfromȱtheȱsystem.ȱ
ExitȱtheȱLearnȱmodeȱwithȱaȱshortȱpressȱonȱtheȱmainȱunitȱbutton.ȱ
Allocation using the keypad
Itȱisȱpossibleȱtoȱperformȱallocationȱviaȱtheȱkeypadȱinȱtwoȱdifferentȱways:ȱRFȱAllocationȱorȱ
byȱenteringȱtheȱdevice’sȱserialȱcode.ȱ
ȱ
ToȱperformȱRFȱAllocationȱviaȱtheȱkeypad,ȱfollowȱthisȱprocedure:ȱ
1. GoȱtoȱtheȱEngineerȱmenuȱandȱselectȱProgrammingȱÆȱRadioȱDeviceȱÆȱAllocationȱ
Æȱ1)ȱRFȱAllocation.ȱTheȱsystemȱimmediatelyȱgoesȱintoȱLearnȱmode.ȱȱ
2. Sendȱaȱtransmissionȱfromȱtheȱdevice.ȱ(Seeȱtable:ȱTransmittersȱwriteȱmessageȱmethod)ȱ
3.
Theȱmainȱunitȱwillȱacknowledgeȱtheȱtransmissionȱwithȱaȱsound.ȱWhenȱtheȱsystemȱ
recognizesȱtheȱdeviceȱtheȱkeypadȱLCDȱwillȱdisplayȱtheȱdeviceȇsȱserialȱnumberȱandȱ
category.ȱTheȱsystemȱalsoȱautomaticallyȱallocatesȱtheȱdeviceȱtheȱnextȱavailableȱ
indexȱnumber.ȱȱ
ȱ
Toȱperformȱallocationȱviaȱtheȱkeypadȱusingȱaȱserialȱcode,ȱfollowȱthisȱprocedure:ȱ
1. GoȱtoȱtheȱEngineerȱmenuȱandȱselectȱProgrammingȱÆȱRadioȱDeviceȱÆȱAllocationȱ
Æȱ2)ȱByȱCode.ȱEnterȱtheȱdevice’sȱ11ȱdigitȱserialȱcodeȱnumber.ȱȱ
Page 3-4
AgilityȱEngineerȱManualȱȱ
2.
ȱ
Theȱsystemȱautomaticallyȱrecognizesȱtheȱdeviceȱandȱallocatesȱitȱtheȱnextȱavailableȱ
indexȱnumber.ȱTheȱsystemȱwillȱsoundȱtheȱdeviceȱtypeȱthatȱhasȱbeenȱallocatedȱandȱ
theȱplaceȱitȱhasȱbeenȱallocatedȱto.ȱ
ȱ
Toȱallocateȱzonesȱtoȱaȱpredefinedȱplaceȱviaȱtheȱkeypadȱfollowȱthisȱprocedure:ȱ
ComparedȱtoȱtheȱRFȱandȱCodeȱallocationsȱmentionedȱbefore,ȱwhereȱtheȱwirelessȱelementsȱ
areȱallocatedȱautomaticallyȱbyȱtheȱsystemȱtoȱtheȱfirstȱavailableȱplace,ȱwhenȱitȱcomesȱtoȱ
zonesȱallocationȱtheȱAgilityȱalsoȱenablesȱtheȱallocationȱofȱzonesȱtoȱaȱpreȬdefinedȱlocation.ȱȱ
1. GoȱtoȱtheȱEngineerȱmenuȱandȱselectȱProgrammingȱÆȱRadioȱDeviceȱÆȱAllocationȱ
Æȱ3)ȱZoneȱAllocation.ȱȱ
2.
3.
4.
ȱ.ȱ
Selectȱtheȱzoneȱnumberȱtoȱwhichȱyouȱwantȱtoȱassignȱtheȱdetectorȱandȱpressȱ
Usingȱtheȱarrowȱkeysȱselectȱtheȱallocationȱmethod:ȱRFȱorȱCodeȱallocation.ȱ
ƒ
RFȱallocation:ȱSendȱaȱtransmissionȱfromȱtheȱdevice.ȱ(Seeȱtable:ȱTransmittersȱ
writeȱmessageȱmethod)ȱ
ƒ
Codeȱallocation:ȱEnterȱtheȱdevice’sȱ11ȱdigitȱserialȱcodeȱnumber.ȱ
Theȱsystemȱallocatesȱtheȱdetectorȱintoȱtheȱselectedȱindexȱnumber.ȱTheȱsystemȱwillȱ
soundȱtheȱdeviceȱtypeȱthatȱhasȱbeenȱallocatedȱandȱtheȱplaceȱitȱhasȱbeenȱallocatedȱ
to.ȱ
Allocation using the Configuration Software
Itȱisȱpossibleȱtoȱperformȱwirelessȱdeviceȱallocationȱviaȱtheȱconfigurationȱsoftwareȱinȱtwoȱ
differentȱways:ȱRFȱAllocationȱorȱbyȱenteringȱtheȱdevice’sȱserialȱcode.ȱ
ȱ
ToȱperformȱRFȱallocationȱfromȱtheȱconfigurationȱsoftwareȱȱ
1. EstablishȱCommunicationȱbetweenȱtheȱmainȱunitȱandȱtheȱConfigurationȱsoftware.ȱ
(ForȱmoreȱinformationȱreferȱtoȱtheȱConfigurationȱSoftwareȱManual)ȱ
2. OpenȱtheȱActivitiesȱ>ȱRadioȱDeviceȱAllocationȱscreen.ȱȱ
3.
4.
Clickȱonȱtheȱ
ȱbutton.ȱThisȱoperationȱwillȱsetȱtheȱmainȱunitȱtoȱLearnȱ
mode.ȱTheȱfollowingȱmessageȱappears:ȱ
ȱ
Sendȱaȱtransmissionȱfromȱtheȱdevice.ȱ(Seeȱtableȱbelow)ȱ
Page 3-5
ȱ
5.
AgilityȱEngineerȱManualȱ
Theȱmainȱunitȱwillȱacknowledgeȱtheȱtransmissionȱwithȱaȱsound.ȱWhenȱtheȱsystemȱ
recognizesȱtheȱdeviceȱtheȱRadioȱDeviceȱAllocationȱscreenȱindicatesȱthatȱtheȱstatusȱ
ofȱallocationȱhasȱbeenȱsuccessful.ȱTheȱserialȱnumber,ȱaccessoryȱtypeȱandȱtheȱindexȱ
numberȱinformationȱwillȱbeȱdisplayed.ȱTheȱindexȱnumberȱisȱautomaticallyȱ
addressedȱbyȱtheȱsystem.ȱ
Note:ȱIfȱrequiredȱyouȱcanȱchangeȱtheȱindexȱnumberȱofȱtheȱwirelessȱdeviceȱbyȱselectingȱtheȱ
requiredȱindexȱnumberȱandȱpressingȱtheȱȱȱ
6.
Toȱallocateȱanȱotherȱwirelessȱdeviceȱclickȱonȱtheȱ
stagesȱ3Ȭ7.ȱ
ȱbuttonȱagain.ȱȱȱ
ȱbuttonȱandȱthenȱrepeatȱ
ȱ
ToȱperformȱCodeȱallocationȱfromȱtheȱconfigurationȱsoftwareȱȱ
1. EstablishȱCommunicationȱbetweenȱtheȱmainȱunitȱandȱtheȱConfigurationȱsoftwareȱ
byȱselectingȱCommunication>Connectȱfromȱtheȱmainȱmenu.ȱ(Forȱmoreȱ
informationȱreferȱtoȱtheȱConfigurationȱSoftwareȱManual)ȱ
2. OpenȱtheȱRadioȱDeviceȱAllocationȱscreen.ȱInȱtheȱAllocationȱarea,ȱenterȱtheȱdeviceȇsȱ
serialȱnumber.ȱȱ
Note:ȱTheȱserialȱnumberȱcanȱbeȱfoundȱonȱtheȱdevice.ȱȱ
3.
Selectȱtheȱwirelessȱdeviceȱindexȱnumber.ȱAutomaticȱmeansȱthatȱtheȱindexȱnumberȱ
isȱautomaticallyȱaddressedȱbyȱtheȱsystem,ȱ
4.
5.
Pressȱtheȱ
ȱbutton.ȱ
Theȱmainȱunitȱwillȱacknowledgeȱtheȱtransmissionȱwithȱaȱsound.ȱWhenȱtheȱsystemȱ
recognizesȱtheȱdeviceȱtheȱRadioȱDeviceȱAllocationȱscreenȱindicatesȱthatȱtheȱstatusȱ
ofȱallocationȱhasȱbeenȱsuccessful.ȱ
Page 3-6
AgilityȱEngineerȱManualȱȱ
ȱ
Transmitters Write Message Method
How to send a write message (transmission):
Wireless Device
Sending Write Message
Detector/Contactsȱ
Pressȱtheȱtamperȱswitchȱforȱ3ȱseconds.ȱ
2ȬWayȱKeypadȱ
Pressȱbothȱkeysȱ
leastȱ2ȱseconds.ȱ
ȱandȱ
simultaneouslyȱforȱatȱ
1ȬWayȱKeypadȱ
Pressȱtheȱ
1ȬWayȱKeyȱfobȱ
Pressȱthe±ȱbuttonȱforȱatȱleastȱ2ȱseconds.ȱ
2ȬWayȱRemoteȱControlȱ
Pressȱbothȱkeysȱ
leastȱ2ȱseconds.ȱ
SmokeȱDetectorȱ
Insertȱbattery.ȱWriteȱmessageȱisȱsendȱautomaticallyȱ
withinȱ10ȱseconds.ȱ
Sounderȱ
Pressȱtheȱresetȱswitchȱonȱtheȱsounder.ȱAfterȱaȱsquawkȱisȱ
soundedȱatȱtheȱsounderȱyouȱhaveȱ10ȱsecondsȱtoȱpressȱ
onȱtheȱtamperȱswitchȱforȱatȱleastȱ3ȱseconds.ȱ
Gas,ȱCOȱdetectorsȱ
Pressȱtheȱtestȱbuttonȱforȱ3ȱseconds.ȱ
2ȱPanicȱButtonȱKeyȱfobȱ
Pressȱbothȱbuttonsȱforȱatȱleastȱ7ȱseconds.ȱ
ȱkeyȱtwice.ȱ
ȱandȱ
ȱsimultaneouslyȱforȱatȱ
ȱ
Deleting Wireless Accessories
Deletingȱallȱwirelessȱdevicesȱcanȱbeȱdoneȱmanuallyȱ(fromȱtheȱmainȱunit)ȱorȱfromȱtheȱ
Configurationȱsoftware.ȱ
ȱ
Toȱmanuallyȱdeleteȱallȱwirelessȱaccessoriesȱfromȱtheȱsystem:ȱ
1. PlaceȱDipȱSwitchȱ2ȱtoȱONȱposition.ȱ
2. Pressȱtheȱmainȱunitȱbuttonȱuntilȱitȱsounds.ȱ
3. ReplaceȱDipȱSwitchȱ2ȱtoȱOFFȱposition.ȱȱȱ
ȱ
ToȱdeleteȱaȱwirelessȱaccessoryȱfromȱtheȱWirelessȱKeypadȱ
1. GoȱtoȱtheȱEngineerȱmenusȱandȱselectȱProgrammingȱÆȱRadioȱDeviceȱÆȱ
Modificationȱ
2. Selectȱtheȱdeviceȱcategoryȱ
3. GoȱtoȱParametersȱoption.ȱȱ
4. Selectȱtheȱdeviceȱindexȱnumberȱ
5. GoȱtoȱSerialȱnumberȱoptionȱandȱtypeȱinȱ000000000000.ȱ
6.
Press
.ȱTheȱdeviceȱwillȱbeȱdeletedȱ
Page 3-7
ȱ
AgilityȱEngineerȱManualȱ
ȱ
ToȱdeleteȱaȱwirelessȱaccessoryȱfromȱtheȱsystemȱviaȱtheȱConfigurationȱsoftware:ȱ
1. EstablishȱCommunicationȱbetweenȱtheȱmainȱunitȱandȱtheȱConfigurationȱsoftwareȱ
(ForȱmoreȱinformationȱreferȱtoȱtheȱConfigurationȱSoftwareȱManual)ȱ
2. InȱtheȱRadioȱDeviceȱAllocationȱscreenȱinȱtheȱDeleteȱAccessoriesȱareaȱenterȱtheȱ
deviceȇsȱserialȱcodeȱandȱclickȱtheȱDeleteȱbutton.ȱ
ȱ
ToȱdeleteȱallȱwirelessȱaccessoriesȱfromȱtheȱsystemȱviaȱtheȱConfigurationȱsoftware:ȱ
1. EstablishȱCommunicationȱbetweenȱtheȱmainȱunitȱandȱtheȱConfigurationȱsoftwareȱ
byȱselectingȱCommunication>Connectȱfromȱtheȱmainȱmenu.ȱ(Forȱmoreȱ
informationȱreferȱtoȱtheȱConfigurationȱSoftwareȱManual)ȱ
2. InȱtheȱRadioȱDeviceȱAllocationȱscreenȱinȱtheȱDeleteȱAccessoriesȱarea,ȱclickȱtheȱ
DeleteȱAllȱbutton.ȱWhenȱallȱaccessoriesȱhaveȱbeenȱdeletedȱtheȱscreenȱwillȱ
indicateȱthatȱdeletionȱhasȱbeenȱsuccessful.ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Page 3-8
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Chapter 4 Engineer Menus
Theȱfollowingȱchapterȱdescribesȱtheȱparametersȱandȱprogrammingȱoptionsȱofȱtheȱsystemȱ
andȱradioȱdevices.ȱTheseȱparametersȱcanȱbeȱprogrammedȱviaȱtheȱAgilityȱkeypadȱorȱtheȱ
configurationȱsoftwareȱbyȱtheȱengineer.ȱȱ
Note:ȱAȱnoteȱappearsȱnextȱtoȱtheȱparametersȱthatȱcanȱonlyȱbeȱprogrammedȱviaȱtheȱconfigurationȱsoftware.ȱ
Forȱmoreȱinformationȱregardingȱtheȱinstallationȱandȱuseȱofȱtheȱconfigurationȱsoftwareȱreferȱtoȱtheȱ
ConfigurationȱSoftwareȱmanual.ȱ
Using the Agility keypad keys
TheȱAgilityȱtwoȱwayȱkeypadȱcontainsȱthreeȱLEDȱindicators,ȱanȱLCDȱdisplayȱandȱaȱvarietyȱ
ofȱkeys.ȱTheȱfollowingȱtableȱdescribesȱtheȱtypicalȱusesȱofȱtheȱkeysȱwhenȱinȱprogrammingȱ
mode.ȱȱ
ȱ
Keys
Description
Theȱnumericalȱkeysȱonȱtheȱkeypadȱareȱusedȱasȱquickȱkeys,ȱaȱ
numericalȱsequenceȱusedȱasȱaȱshortcutȱtoȱprogramȱanȱoption.ȱȱ
ToȱprogramȱtheȱsystemȱusingȱQuickȱkeys:ȱ
1.ȱAccessȱtheȱengineerȱmenusȱ(seeȱbelow)ȱandȱselectȱtheȱrelevantȱmainȱmenuȱ
option.ȱȱ
2.ȱPressȱtheȱquickȱkeysȱinȱsequenceȱtoȱlocateȱtheȱparameterȱandȱpressȱ
.ȱ
Numericalȱkeysȱareȱalsoȱusedȱtoȱinputȱtheȱnumericȱcodesȱthatȱmayȱ
beȱrequiredȱforȱsetting,ȱunsetting,ȱorȱusedȱtoȱactivateȱspecificȱ
functions.ȱ
ExitsȱfromȱtheȱcurrentȱmenuȱandȱreturnsȱtoȱNormalȱOperationȱ
modeȱ
Terminatesȱcommandsȱandȱconfirmsȱdataȱtoȱbeȱstoredȱ
Usedȱtoȱbrowseȱthroughȱtheȱmenu:ȱScrollsȱupȱaȱlistȱorȱmovesȱtheȱ
cursorȱ
ȱ
Changesȱdataȱ
Page 4-1
AgilityȱEngineerȱManualȱ
ȱ
Accessing the Engineer Menus
ToȱaccessȱtheȱengineerȱmenusȱviaȱtheȱAgilityȱkeypad,ȱfollowȱthisȱprocedure:ȱ
Pressȱtheȱ
ȱkeyȱto activateȱtheȱkeypad.ȱ
Enterȱtheȱengineerȱcodeȱ0132ȱ(defaultȱcode).ȱ
Note:ȱIfȱtheȱAuthorizeȱEngineerȱsystemȱbitȱisȱdefinedȱasȱYES,ȱaȱGrandȱMasterȱcodeȱisȱrequiredȱtoȱ
authorizeȱtheȱengineerȱtoȱenterȱtheȱprogrammingȱmode.ȱInȱthisȱcaseȱtheȱGrandȱMasterȱcodeȱ
shouldȱbeȱenteredȱafterȱtheȱengineerȱcodeȱviaȱtheȱGrandȱMasterȱmenuȱÆȱActivitiesÆȱ
AuthorizeȱEngineer.ȱȱ
Theȱfollowingȱmenuȱappearsȱdisplayingȱaȱlistȱofȱallȱtheȱengineerȱmenus:ȱ
1) Programmingȱ
2) Testingȱ
3) Activitiesȱ
4) FollowȱMeȱ
5) Clockȱ
6) EventȱLogȱ
7) Macroȱ
Usingȱtheȱ
ȱkeysȱtoȱselectȱtheȱoptions.ȱȱ
Programming Menu
Allȱtheȱsystemȱparametersȱareȱprogrammedȱbyȱtheȱengineerȱviaȱtheȱprogrammingȱmenu.ȱȱ
Afterȱaccessingȱtheȱengineerȱmenus,ȱselectȱtheȱ1)ȱProgrammingȱoption.ȱTheȱfollowingȱlistȱ
appears:ȱ
1.ȱSystemȱ
2.ȱRadioȱDevicesȱȱ
3.ȱCodesȱȱ
4.ȱCommunicationȱȱ
5.ȱAudioȱ
6.ȱExitȱ
1. Programming: System Menu
TheȱSystemȱmenuȱprovidesȱaccessȱtoȱparametersȱthatȱareȱusedȱforȱprogrammingȱ
configurationȱsettingsȱapplicableȱtoȱtheȱentireȱsystem.ȱTheȱSystemȱmenuȱisȱdividedȱintoȱtheȱ
followingȱsubȬmenus:ȱ
1.ȱTimersȱ
2.ȱControlsȱ
3.ȱLabelsȱ
Page 4-2
AgilityȱEngineerȱManualȱ
ȱ
4.ȱSoundsȱ
5.ȱSettingsȱ
6.ȱServiceȱInformationȱ
7.ȱFirmwareȱUpdateȱ
1.1 Timers
TheȱTimersȱmenuȱcontainsȱparametersȱthatȱspecifyȱtheȱdurationȱofȱanȱaction.ȱ
System: Timers
Parameter
Default
Range
Exit/EntryȱDelayȱ1ȱ ȱ
ȱ
ȱ
Theȱamountȱofȱtimeȱbeforeȱtheȱsystemȱisȱset/unset.ȱUsuallyȱusedȱonȱfrontȱentranceȱdoor.ȱȱ
ȱȱȱȱEntryȱDelayȱ1ȱ
ȱ
30ȱsecȱ
0Ȭ255ȱsecȱ
45ȱsecȱ
0Ȭ255ȱsecȱ
ȱ
ȱ
ȱȱȱȱDurationȱofȱentryȱdelayȱ1ȱbeforeȱtheȱsystemȱisȱunset.ȱ
ȱȱȱȱExitȱDelayȱ1ȱ
ȱ
ȱȱȱȱDurationȱofȱexitȱdelayȱ1ȱbeforeȱtheȱsystemȱisȱset.ȱ
Exit/EntryȱDelayȱ2ȱ ȱ
Theȱamountȱofȱtimeȱbeforeȱtheȱsystemȱisȱset/unset.ȱUsuallyȱusedȱtoȱbackȱdoor.ȱ
ȱȱȱȱEntryȱDelayȱ2ȱ
ȱ
45ȱsecȱ
0Ȭ255ȱsecȱ
60ȱsecȱ
0Ȭ255ȱsecȱ
ȱȱȱȱDurationȱofȱentryȱdelayȱ2ȱbeforeȱtheȱsystemȱisȱunset.ȱ
ȱȱȱȱExitȱDelayȱ2ȱ
ȱ
ȱȱȱȱDurationȱofȱexitȱdelayȱ2ȱbeforeȱtheȱsystemȱisȱset.ȱ
BellȱTimeoutȱ
ȱ
04ȱminȱ 01Ȭ90ȱminȱ
Durationȱofȱtheȱsounderȱduringȱalarm.ȱ
BellȱDelayȱ
ȱ
00ȱminȱ 00Ȭ90ȱminȱ
Theȱtimeȱdelayȱbeforeȱaȱsounderȱsoundȱisȱproducedȱafterȱtriggeringȱanȱalarm.ȱȱ
ACȱOffȱDelayȱ
ȱ
30ȱminȱ 0Ȭ255ȱminȱ
InȱtheȱcaseȱofȱaȱlossȱofȱACȱpower,ȱthisȱparameterȱspecifiesȱtheȱdelayȱperiodȱbeforeȱ
reportingȱtheȱeventȱorȱoperatingȱtheȱProgrammableȱOutput.ȱIfȱtheȱdelayȱtimeȱisȱsetȱtoȱ
zero,ȱthereȱwillȱbeȱnoȱdelayȱperiod.ȱ
JammingȱTimeȱ
Noneȱ
None,ȱ10,ȱ20ȱorȱ30ȱsecȱ
Specifiesȱtheȱperiodȱofȱtimeȱthatȱtheȱsystemȇsȱreceiverȱtoleratesȱunwantedȱradioȱ
frequenciesȱcapableȱofȱblockingȱ(jamming)ȱsignalsȱproducedȱbyȱtheȱsystemȇsȱtransmitters.ȱ
Onceȱtheȱspecifiedȱtimeȱisȱreached,ȱtheȱsystemȱsendsȱaȱreportȱcodeȱtoȱtheȱalarmȱreceivingȱ
centerȱorȱactivatesȱaȱlocalȱsounder,ȱdependingȱonȱtheȱAudibleȱJammingȱsystemȱcontrol.ȱ
NONE:ȱNoȱjammingȱwillȱbeȱdetectedȱorȱreported.ȱ
Page 4-3
ȱ
AgilityȱEngineerȱManualȱ
ȱ
System: Timers
Parameter
Default
RXȱSupervisionȱ
3ȱhours 0Ȭ7ȱhoursȱ
Range
Specifiesȱhowȱoftenȱtheȱsystemȱexpectsȱtoȱgetȱaȱsignalȱfromȱtheȱsystemȇsȱtransmitters.ȱIfȱaȱ
signalȱfromȱaȱzoneȱisȱnotȱreceivedȱduringȱtheȱspecifiedȱtimeȱtheȱzoneȱwillȱbeȱregardedȱasȱ
lost,ȱtheȱsystemȱwillȱsendȱaȱreportȱcodeȱtoȱtheȱalarmȱreceivingȱcenter,ȱandȱtheȱsystemȱ
statusȱwillȱbeȱȈNotȱReadyȈ.ȱ
Notes:ȱ0ȱhoursȱdisablesȱsupervisionȱ
ȱ
Itȱisȱrecommendedȱtoȱsetȱtheȱsupervisionȱtimeȱtoȱaȱminimumȱofȱ3ȱhoursȱ
TXȱSupervisionȱ
058ȱ
0Ȭ255ȱminȱ
SpecifiesȱhowȱoftenȱaȱbiȬdirectionalȱwirelessȱdeviceȱgeneratesȱaȱsupervisionȱrequestȱtoȱtheȱ
system.ȱ
IfȱanȱaccessoryȱdoesȱnotȱgenerateȱaȱsupervisionȱsignalȱduringȱtheȱRXȱSupervisionȱtime,ȱ
theȱsystemȱwillȱregardȱtheȱaccessoryȱasȱLost.ȱ
Note:ȱTheȱdeviceȱwillȱgenerateȱtheȱsupervisionȱmessageȱaccordingȱtoȱtheȱtimeȱdefined.ȱ
Important:ȱTheȱRXȱSupervisionȱtimeȱshouldȱbeȱhigherȱthanȱtheȱTxȱSupervisionȱtimeȱinȱorderȱtoȱeliminateȱ
falseȱlostȱevent.ȱ
RedialȱWaitȱȱ
30ȱsecȱ
0Ȭ255ȱsecȱ
Theȱnumberȱofȱsecondsȱbetweenȱattemptsȱatȱredialingȱtheȱsameȱphoneȱnumber.ȱȱ
AppliesȱtoȱbothȱtheȱARCȱRetriesȱandȱFMȱRetriesȱparameters.ȱȱ
Note:ȱUsedȱforȱbothȱPSTNȱandȱGSM.ȱ
Moreȱ
ȱ
ȱ
ȱȱȱȱSwingerȱLimitȱShutdownȱ
00ȱ
0Ȭ15ȱtimesȱ
Aȱswingerȱisȱaȱrepeatedȱviolationȱofȱtheȱsameȱzone,ȱoftenȱresultingȱinȱaȱnuisanceȱalarmȱ
andȱusuallyȱdueȱtoȱaȱmalfunction,ȱanȱenvironmentalȱproblem,ȱorȱtheȱincorrectȱ
installationȱofȱaȱdetectorȱorȱsensor.ȱ
Thisȱparameterȱspecifiesȱtheȱnumberȱofȱviolationsȱofȱtheȱsameȱzoneȱreportedȱduringȱaȱ
singleȱsetȱperiod,ȱbeforeȱtheȱzoneȱisȱautomaticallyȱomitted.ȱ
toȱdisablesȱtheȱswingerȱshutdownȱ
ȱȱȱȱNoȱActivityȱ
00ȱ
0Ȭ99ȱhoursȱ
Determinesȱtheȱtimeȱlimitȱforȱreceptionȱofȱsignalsȱfromȱsensorsȱusedȱtoȱmonitorȱtheȱ
activityȱofȱsick,ȱelderlyȱorȱdisabledȱpeople.ȱIfȱnoȱsignalȱisȱreceivedȱfromȱaȱzoneȱdefinedȱ
withȱtheȱȈNoȱActivityȈȱfeatureȱȱatȱleastȱonceȱwithinȱtheȱdefinedȱtimeȱlimit,ȱaȱ“noȬ
activity”ȱalertȱcanȱbeȱsendȱtoȱFollowȱMeȱdestination,ȱaȱlocalȱmessageȱcanȱbeȱheardȱandȱaȱ
reportȱtoȱȱARCȱcanȱbeȱdefinedȱtoȱbeȱsend.ȱȱ
Options:ȱ0ȱ=thisȱparameterȱisȱinactive.ȱ
Page 4-4
AgilityȱEngineerȱManualȱ
ȱ
ȱ
System: Timers
Parameter
Default
Range
ȱȱȱȱLastȱExitȱSoundȱ
00ȱ
0Ȭ255ȱsecondsȱ
DefinesȱtheȱlastȱsecondsȱofȱtheȱExitȱTimeȱthatȱtheȱbeepȱsoundȱwillȱchangeȱ(mainȱunitȱ
andȱkeypads),ȱindicatingȱtoȱtheȱuserȱthatȱExitȱTimeȱisȱaboutȱtoȱend.ȱ
1.2 Controls
TheȱControlȱmenuȱcontainsȱparametersȱthatȱcontrolȱspecificȱsystemȱoperations.ȱ
System: Controls
Parameter
Default
Basicȱprogrammingȱ
QuickȱSetȱ
ȱ
YESȱ
YES:ȱEliminatesȱtheȱneedȱforȱaȱuserȱcodeȱwhenȱsettingȱ(Fullȱorȱpartial)ȱtheȱsystemȱbyȱaȱ
keypadȱorȱ2Ȭwayȱremoteȱcontrol.ȱ
NO:ȱAȱvalidȱuserȱcodeȱisȱrequiredȱforȱsettingȱusingȱaȱkeypadȱorȱremoteȱcontrol.ȱ
AllowȱOmitȱ
ȱ
YESȱ
YES:ȱPermitsȱzoneȱomittingȱbyȱauthorizedȱsystemȱusersȱafterȱenteringȱaȱvalidȱuserȱcode.ȱ
NO:ȱZoneȱomittingȱisȱNOTȱpermitted.ȱ
QuickȱStatusȱ
YESȱ
YES:ȱAȱuserȱcodeȱisȱnotȱrequiredȱbeforeȱpressingȱtheȱstatusȱkey/buttonȱonȱyourȱwirelessȱ
keypadȱorȱbiȬdirectionalȱremoteȱcontrol.ȱ
NO:ȱAȱuserȱcodeȱisȱrequiredȱtoȱactivateȱtheȱstatusȱkey.ȱ
FalseȱCodeȱFaultȱ
YESȱ
YES:ȱAȱfalseȱcodeȱreportȱisȱsentȱtoȱtheȱalarmȱreceivingȱcenterȱafterȱfiveȱsuccessiveȱ
attemptsȱatȱsettingȱorȱunsettingȱinȱwhichȱanȱincorrectȱuserȱcodeȱisȱentered.ȱNoȱalarmȱ
soundsȱatȱtheȱpremises,ȱbutȱaȱfaultȱindicationȱappears.ȱTheȱwirelessȱkeypadȱwillȱbeȱlockedȱ
forȱ30ȱminutes.ȱȱ
NO:ȱAȱlocalȱalarmȱisȱsoundedȱatȱtheȱpremises.ȱ
SounderȱSquawkȱ
ȱ
YESȱ
YES:ȱSettingȱorȱunsettingȱtheȱsystemȱusingȱaȱremoteȱcontrol,ȱwirelessȱkeypadȱorȱaȱkeyȬ
switchȱȱproducesȱaȱbriefȱȈchirpȈȱandȱactivatesȱtheȱstrobeȱasȱfollows:ȱ
x Oneȱchirpȱindicatesȱtheȱsystemȱisȱsetȱ(alsoȱwhenȱsettingȱwithȱaȱkeypad).ȱ
x Twoȱchirpsȱindicateȱtheȱsystemȱisȱunset.ȱ
x Fourȱchirpsȱindicateȱtheȱsystemȱisȱunsetȱafterȱanȱalarm.ȱ
NO:ȱNoȱȈchirpȈȱisȱproduced.ȱ
Page 4-5
AgilityȱEngineerȱManualȱ
ȱ
System: Controls
Parameter
AudibleȱPanicȱ
Default
ȱ
NOȱ
YES:ȱTheȱsoundersȱoperateȱwhenȱaȱȈPoliceȱAlarmȈȱisȱinitiatedȱatȱtheȱkeypadȱ(ifȱdefined),ȱ
theȱremoteȱcontrolȱorȱwhenȱaȱpanicȱzoneȱisȱactivated.ȱ
NO:ȱNoȱsounderȱoperationȱoccursȱduringȱaȱȈPanicȱAlarm,Ȉȱmakingȱtheȱalarmȱtrulyȱ
ȈsilentȈȱ(SilentȱPanic).ȱ
Note:ȱTheȱsystemȱalwaysȱtransmitsȱaȱpanicȱreportȱtoȱtheȱalarmȱreceivingȱcenter.ȱ ȱ
BuzzerȱÆȱȱBellȱ
NOȱ
YES:ȱIfȱanȱalarmȱoccursȱwhenȱtheȱsystemȱisȱsetȱinȱtheȱPartȱSetȱmode,ȱaȱbuzzerȱsoundsȱforȱ
15ȱsecondsȱbeforeȱtheȱsoundersȱoperate.ȱ
NO:ȱAnȱalarmȱinȱtheȱPartȱSetȱmodeȱcausesȱsoundersȱtoȱoperateȱsimultaneously.ȱ
AudibleȱJammingȱ
NOȱ
RelatesȱtoȱtheȱJammingȱTimeȱparameter.ȱ
YES:ȱOnceȱtheȱspecifiedȱtimeȱisȱreached,ȱtheȱsystemȱactivatesȱtheȱsounderȱandȱsendsȱaȱ
reportȱcodeȱtoȱtheȱalarmȱreceivingȱcenter.ȱȱ
NO:ȱOnceȱtheȱspecifiedȱtimeȱisȱreachedȱtheȱsoundersȱdoȱnotȱoperate.ȱ
ExitȱBeepsȱatȱPartȱSetȱ
YESȱ
DeterminesȱwhetherȱtheȱsystemȱwillȱsoundȱbeepsȱduringȱexitȱtimeȱinȱPartȱSetting.ȱ
YES:ȱExitȱbeepsȱwillȱsoundȱ
NO:ȱExitȱbeepsȱwillȱnotȱsoundȱ
ForcedȱDeviceȱSettingȱ
YESȱ
YES:ȱSettingȱaȱpartition,ȱusingȱaȱremoteȱcontrolȱorȱkeyȬswitchȱcanȱbeȱperformedȱwithȱ
violatedȱ(notȱready)ȱzonesȱinȱtheȱsystem.ȱȱAnyȱviolatedȱ(notȱready)ȱzone(s)ȱinȱtheȱ
partitionȱwillȱbeȱomittedȱautomatically.ȱTheȱpartitionȱisȱthenȱȈforceȱset,Ȉȱandȱallȱintactȱ
zonesȱareȱcapableȱofȱproducingȱanȱalarm.ȱ
NO:ȱTheȱpartitionȱcannotȱbeȱsetȱuntilȱallȱviolatedȱ(notȱready)ȱzonesȱareȱsecured.ȱ
Page 4-6
AgilityȱEngineerȱManualȱ
ȱ
ȱ
System: Controls
Parameter
Default
SetȱPreȬwarningȱ
YESȱ
RelatedȱtoȱautoȱSet/Unsetȱoperation.ȱ
YES:ȱForȱanyȱpartition(s)ȱsetȱupȱforȱAutoȱSetting,ȱanȱaudibleȱExitȱDelayȱ(warning)ȱ
countdownȱwillȱcommenceȱ4.25ȱminutesȱpriorȱtoȱtheȱautomaticȱSetting.ȱDuringȱthisȱ
period,ȱExitȱDelayȱbeepsȱwillȱbeȱheard.ȱȱ
YouȱcanȱenterȱaȱvalidȱUserȱCodeȱatȱanyȱtimeȱduringȱtheȱcountdownȱtoȱdelayȱtheȱ
partitionȇsȱautomaticȱSettingȱbyȱ45ȱminutes.ȱ
WhenȱanȱȈAutoȬSetȈȱpartitionȱisȱunset,ȱasȱdescribedȱabove,ȱitȱcanȱnoȱlongerȱbeȱ
automaticallyȱsetȱduringȱtheȱcurrentȱday.ȱ
Theȱextendedȱ4.25ȱminutesȱwarningȱdoesȱnotȱapplyȱtoȱautomaticȱPartialȱSetting.ȱ
NO:ȱAutoȱSettingȱforȱanyȱprogrammedȱpartition(s)ȱtakesȱplaceȱatȱtheȱdesignatedȱtime.ȱ
TheȱprogrammedȱExitȱDelayȱperiodȱandȱanyȱaudibleȱsignalȱoccurȱasȱexpected.ȱ
DefaultȱEnableȱ
YESȱ
ThisȱoptionȱȱcontainsȱparametersȱthatȱrelateȱtoȱwhatȱhappensȱtoȱtheȱEngineer,ȱSubȬ
EngineerȱandȱGrandȱMasterȱcodesȱifȱtheȱMainȱPanelȇsȱDEFAULTȱDipȱSwitchȱ2ȱisȱinȱplaceȱ
whenȱpowerȱtoȱtheȱMainȱPanelȱisȱswitchedȱoffȱandȱthenȱon.ȱForȱmoreȱinformationȱ
regardingȱpanelȱdefaultsȱreferȱtoȱChapterȱ2,ȱDipȱSwitchȱSetting,ȱseeȱexplanationȱofȱDipȱ
Switchȱ2.ȱ
YES:ȱTheȱEngineer,ȱSubȬEngineerȱandȱGrandȱMasterȱcodesȱwillȱreturnȱtoȱtheȱoriginal,ȱ
factoryȱdefaultȱvalues.ȱȱ
NO:ȱTheȱEngineer,ȱSubȬEngineerȱandȱGrandȱMasterȱcodesȱwillȱNOTȱreturnȱtoȱtheȱ
original,ȱfactoryȱdefaultȱvaluesȱbyȱanȱunauthorizedȱuser.ȱȱ
MainȱButton:ȱStatusȬY/TalkȬNȱ
YESȱ
TheȱAgilityȱenablesȱtheȱARCȱtoȱperformȱListenȬInȱandȱTalkȱfunctionsȱinȱorderȱtoȱverifyȱaȱ
causeȱofȱeventȱorȱtoȱguideȱsomeoneȱinȱdistress.ȱTheȱMainȱButton:ȱStatusȬY/TalkȬNȱ
parameterȱdeterminesȱtheȱfunctionȱofȱtheȱbuttonȱonȱtheȱsurfaceȱofȱtheȱmainȱunitȱtoȱenableȱ
ListenȬInȱandȱTalk.ȱ
YES:ȱStatusȱbuttonȱ–ȱTheȱsystemȱwillȱrelayȱtheȱsystemȱstatus.ȱ
NO:ȱServiceȱcallȱbuttonȱ–ȱTheȱsystemȱdialsȱtheȱARCȱtoȱestablishȱ2Ȭwayȱcommunication.ȱ
QuickȱLearnȱ
YESȱ
Enablesȱtheȱbuttonȱonȱtheȱsurfaceȱofȱtheȱmainȱunitȱtoȱperformȱquickȱallocationȱofȱwirelessȱ
devices.ȱ(SeeȱChapterȱ3ȱSystemȱDeviceȱAllocation:ȱManualȱSetup)ȱ
YES:ȱQuickȱlearnȱmodeȱisȱenabled.ȱLongȱpressȱonȱtheȱmainȱunitȱbuttonȱwillȱstartȱLearnȱ
mode.ȱTheȱLEDsȱonȱtheȱmainȱunitȱwillȱstartȱflashingȱoneȱafterȱtheȱotherȱ
NO:ȱQuickȱlearningȱmodeȱisȱdisabled.ȱTheȱmainȱunitȱbuttonȱisȱnotȱinȱLearnȱmode.ȱ
Page 4-7
AgilityȱEngineerȱManualȱ
ȱ
System: Controls
Parameter
Default
Advancedȱprogrammingȱ
Areaȱȱ
NOȱ
ChangesȱtheȱsystemȱoperationȱtoȱAreaȱinsteadȱofȱPartition,ȱwhichȱthenȱchangesȱonlyȱtheȱ
operationȱofȱaȱcommonȱzone.ȱ
YES:ȱWhenȱselected,ȱtheȱfollowingȱpointsȱareȱrelevant:ȱ
x Aȱcommonȱzoneȱwillȱbeȱsetȱafterȱanyȱpartitionȱisȱset.ȱ
x Aȱcommonȱzoneȱwillȱbeȱunsetȱonlyȱwhenȱallȱpartitionsȱareȱunset.ȱ
NO:ȱWhenȱselected,ȱtheȱfollowingȱpointsȱareȱrelevant:ȱ
x Aȱcommonȱzoneȱwillȱbeȱsetȱonlyȱwhenȱallȱpartitionsȱareȱset.ȱȱ
x Aȱcommonȱzoneȱwillȱbeȱunsetȱwhenȱanyȱpartitionȱisȱunset.ȱ
GlobalȱFollowerȱ
NOȱ
YES:ȱSpecifiesȱthatȱallȱzonesȱ(thatȱareȱprogrammedȱtoȱfollowȱanȱExit/EntryȱDelayȱtime)ȱ
willȱfollowȱtheȱExit/EntryȱDelayȱtimeȱofȱanyȱsetȱpartition.ȱ
NO:ȱSpecifiesȱthatȱallȱzonesȱ(thatȱareȱprogrammedȱtoȱfollowȱanȱEntryȱDelayȱtime)ȱwillȱ
followȱtheȱEntryȱDelayȱtimeȱofȱonlyȱtheȱpartitionsȱtoȱwhichȱtheyȱareȱassigned.ȱ
Summer/Winterȱȱ
NOȱ
YES:ȱTheȱsystemȱautomaticallyȱsetsȱitsȱtimeȱofȱdayȱclockȱoneȱhourȱaheadȱinȱtheȱspringȱ(onȱ
theȱlastȱSundayȱinȱMarch)ȱandȱoneȱhourȱbackȱinȱtheȱAutumnȱ(onȱtheȱlastȱSundayȱinȱ
October).ȱ
NO:ȱNoȱautomaticȱtimeȱaccommodationȱisȱmade.ȱ
24ȱHourȱOmitȱ
NOȱ
YES:ȱItȱisȱpossibleȱforȱtheȱuserȱtoȱomitȱaȱ24Ȭhourȱzone.ȱ
NO:ȱItȱisȱnotȱpossibleȱforȱtheȱuserȱtoȱomitȱaȱ24Ȭhourȱzone.ȱ
TamperȱResetȱ
NOȱȱ
YES:ȱItȱisȱnecessaryȱtoȱenterȱtheȱEngineerȱCodeȱtoȱresetȱaȱTamperȱalarm.ȱTherefore,ȱ
resettingȱaȱTamperȱalarmȱrequiresȱtheȱinterventionȱofȱtheȱalarmȱcompany.ȱHowever,ȱtheȱ
systemȱcanȱstillȱbeȱset.ȱ
NO:ȱCorrectingȱtheȱproblemȱresetsȱaȱTamperȱalarm,ȱrequiringȱnoȱalarmȱcompanyȱhelp.ȱ
EngineerȱResetȱ
NOȱȱ
YES:ȱItȱisȱnecessaryȱtoȱenterȱtheȱEngineerȱCodeȱtoȱresetȱanȱalarmedȱpartitionȱafterȱitȱhasȱ
beenȱunset.ȱThisȱrequiresȱtheȱinterventionȱofȱtheȱalarmȱcompany.ȱȱ
Note:ȱBeforeȱtheȱReadyȱLEDȱcanȱlightȱallȱzonesȱwithinȱtheȱpartitionȱmustȱbeȱsecured.ȱ
NO:ȱOnceȱanȱalarmedȱpartitionȱisȱresetȱtheȱReadyȱLEDȱlightsȱwhenȱallȱzonesȱareȱsecured.ȱ
Page 4-8
AgilityȱEngineerȱManualȱ
ȱ
ȱ
System: Controls
Parameter
Default
EngineerȱTamperȱ
NOȱ
YES:ȱAfterȱaȱTamperȱalarm,ȱtheȱsystemȱisȱnotȱreadyȱtoȱset.ȱThisȱrequiresȱtheȱinterventionȱ
ofȱtheȱalarmȱcompany.ȱ
NO:ȱAfterȱaȱTamperȱalarmȱisȱrestoredȱtheȱsystemȱisȱready.ȱ
LowȱBatteryȱȱSetȱ
YESȱ
YES:ȱAllowsȱsettingȱofȱtheȱsystemȱwhenȱaȱlowȱbatteryȱconditionȱisȱdetectedȱinȱtheȱmainȱ
unit.ȱ
NO:ȱSettingȱtheȱsystemȱisȱdisabledȱwhenȱaȱlowȱbatteryȱconditionȱisȱdetected.ȱ
SounderȱPreȬAlarmȱ ȱ
NOȱ
SpecifiesȱifȱtheȱsystemȱwillȱsendȱaȱpreȬalarmȱmessageȱtoȱtheȱsounderȱwhileȱanȱentryȱdelayȱ
starts.ȱȱ
YES:ȱTheȱsystemȱsendsȱaȱpreȬalarmȱsignalȱtoȱtheȱsounderȱatȱtheȱbeginningȱofȱtheȱentryȱ
delay.ȱIfȱtheȱsounderȱdoesȱnotȱreceiveȱaȱcancellationȱsignalȱfromȱtheȱsystemȱatȱtheȱendȱofȱ
theȱentryȱtime,ȱtheȱsounderȱgoesȱintoȱalarm.ȱȱ
NO:ȱPreȬAlarmȱdisabledȱȱȱ
Bellȱ30/10ȱ
NOȱ
YES:ȱTheȱsoundersȱceaseȱtoȱsoundȱforȱ10ȱsecondsȱafterȱeachȱ30ȱsecondsȱofȱoperation.ȱ
NO:ȱTheȱsoundersȱoperateȱwithoutȱinterruption.ȱ
FireȱAlarmȱPatternȱ
NOȱ
YES:ȱDuringȱaȱfireȱalarm,ȱtheȱsoundersȱproduceȱaȱpatternȱofȱ3ȱshortȱburstsȱfollowedȱbyȱaȱ
briefȱpause.ȱ
NO:ȱDuringȱaȱfireȱalarm,ȱtheȱflowȱofȱsoundsȱproducedȱbyȱtheȱsounderȱisȱaȱpatternȱofȱ2ȱ
secondsȱON,ȱthenȱ2ȱsecondsȱOFF.ȱ
IMQȱ
NOȱ
YES:ȱCausesȱtheȱfollowingȱparametersȱtoȱfunctionȱasȱfollows:ȱ
Œ
AutoȱSetȱOmit:ȱIfȱthereȱisȱanȱopenȱzoneȱduringȱtheȱAutoȱSetȱprocess,ȱtheȱsystemȱwillȱ
beȱset,ȱandȱaȱsilentȱalarmȱwillȱbeȱactivatedȱ(unlessȱtheȱopenȱzoneȱisȱclosed).ȱ
Œ
Aȱprogrammingȱoutputȱdefinedȱasȱ“AutoȱSetȱAlarm”ȱisȱactivated.ȱ
Œ
Aȱprogrammingȱoutputȱdefinedȱasȱ“ZoneȱLossȱAlarm”ȱisȱactivatedȱȱ
NO:ȱCausesȱtheȱfollowingȱparametersȱtoȱfunctionȱasȱfollows:ȱ
Œ
AutoȱSetȱOmit:ȱIfȱtheȱAutoȱSetȱprogrammingȱsetsȱtheȱsystemȱandȱthereȱisȱanȱopenȱ
zoneȱduringȱtheȱautoȱset,ȱtheȱsystemȱwillȱomitȱtheȱopenȱzonesȱandȱsetȱtheȱsystem.ȱ
Œ
Aȱprogrammingȱoutputȱdefinedȱasȱ“AutoȱSetȱAlarm”ȱisȱdeactivated.ȱ
Œ
Aȱprogrammingȱoutputȱdefinedȱasȱ“ZoneȱLossȱAlarm”ȱisȱdeactivated.ȱ
Note:ȱtheȱIMQȱfeatureȱisȱforȱtheȱItalianȱmarket.ȱ
Page 4-9
AgilityȱEngineerȱManualȱ
ȱ
System: Controls
Parameter
Default
DisableȱIncomingȱCallȱ
ȱ
NOȱ
Thisȱparameterȱisȱusedȱtoȱdisableȱallȱincomingȱcallsȱtryingȱtoȱcomeȱinȱviaȱtheȱvoiceȱ
channelȱ(PSTNȱorȱGSM).ȱȱ
YES:ȱIncomingȱcallsȱfromȱvoiceȱchannelȱareȱdisabled.ȱ
NO:ȱIncomingȱcallsȱfromȱvoiceȱchannelȱareȱenabled.ȱ
Note:ȱIncomingȱdataȱcallȱviaȱtheȱGSMȱdataȱchannelȱisȱstillȱenabled.ȱ
Communicationȱȱ
ARCȱEnableȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱYESȱ
YES:ȱEnablesȱcommunicationȱwithȱtheȱCentralȱStationȱtoȱreportȱalarms,ȱfault,ȱandȱ
supervisoryȱevents.ȱ
NO:ȱNoȱcommunicationȱwithȱtheȱCentralȱStationȱisȱpossible.ȱChooseȱNOȱforȱinstallationsȱ
thatȱareȱNOTȱmonitoredȱbyȱaȱCentralȱStation.ȱ
ConfigurationȱSoftwareȱEnableȱ
ȱ
YESȱ
YES:ȱEnablesȱcommunicationȱbetweenȱtheȱalarmȱcompanyȱandȱtheȱsystemȱusingȱtheȱ
Configurationȱsoftware.ȱThisȱenablesȱmodifyingȱanȱinstallationȇsȱconfiguration,ȱobtainingȱ
statusȱinformation,ȱandȱissuingȱMainȱPanelȱcommands,ȱallȱfromȱaȱremoteȱlocation.ȱ
NO:ȱDisablesȱcommunication,ȱasȱdetailedȱabove.ȱ
FMȱEnableȱ
ȱ
YESȱ
YES:ȱEnablesȱFollowȬMeȱcommunication.ȱ
IfȱbothȱtheȱARCȱphonesȱandȱtheȱFMȱphonesȱareȱdefined,ȱtheȱsystemȱwillȱfirstȱcallȱtheȱARCȱ
phonesȱandȱthenȱtheȱFMȱphones.ȱ
NO:ȱDisablesȱFollowȬMeȱcommunication.ȱ
ENȱ50131ȱprogrammingȱ
AuthorizeȱEngineerȱ
NOȱ
ThisȱoptionȱlimitsȱtheȱEngineerȱandȱSubȬengineerȱauthorizationȱtoȱaccessȱtheȱ
programmingȱmenu.ȱ
YES:ȱAȱGrandȱMasterȱcodeȱisȱrequiredȱtoȱauthorizeȱtheȱengineerȱtoȱenterȱtheȱ
programmingȱmodeȱforȱ1ȱhour.ȱ
NO:ȱTheȱEngineerȱdoesȱnotȱneedȱanȱauthorizationȱcode.ȱ
Page 4-10
AgilityȱEngineerȱManualȱ
ȱ
ȱ
System: Controls
Parameter
Default
OverrideȱFaultȱȱ
YESȱ
Specifiesȱifȱtheȱsystem/partitionȱcanȱbeȱsetȱwhenȱthereȱisȱaȱfaultȱinȱtheȱsystem.ȱ
YES:ȱTheȱsystemȱwillȱsetȱevenȱifȱthereȱisȱaȱfaultȱinȱtheȱsystem.ȱ
NO:ȱWhenȱtheȱuserȱstartsȱtheȱsettingȱprocessȱandȱthereȱisȱaȱsystemȬfault,ȱtheȱuserȱmustȱ
confirmȱthatȱheȱisȱawareȱofȱallȱfaultsȱbeforeȱcontinuingȱwithȱtheȱSettingȱprocess.ȱȱ
ThisȱisȱdoneȱviaȱtheȱUserȱmenuÆActivitiesÆOmitȱFault.ȱ
Theȱsystemȱwillȱnotȱsetȱduringȱforcedȱsettingȱifȱaȱfaultȱoccurredȱinȱtheȱsystemȱ
NOȱ
RestoreȱAlarmȱ
YES:ȱTheȱuserȱmustȱconfirmȱthatȱheȱisȱawareȱthatȱalarmȱoccurredȱinȱtheȱsystemȱbeforeȱ
resettingȱtheȱsystem.ȱTheȱsystemȱwillȱbeȱinȱȈNotȱReadyȈȱstatusȱuntilȱheȱconfirmsȱtheȱ
alarm.ȱThisȱisȱdoneȱviaȱtheȱUserȱmenuÆActivitiesÆAdvancedÆRestoreȱAlarm.ȱ
NO:ȱTheȱuserȱdoesȱnotȱneedȱtoȱconfirmȱtheȱalarmȱbeforeȱresettingȱtheȱsystem.ȱ
NOȱ
MandatoryȱEventȱLogȱ
YES:ȱOnlyȱmandatoryȱeventsȱ(specifiedȱinȱtheȱENȱstandard)ȱwillȱbeȱdisplayedȱinȱtheȱ
EventȱLog.ȱȱ
NO:ȱAllȱtheȱeventsȱwillȱbeȱdisplayedȱinȱtheȱEventȱLog.ȱ
NOȱ
RestoreȱFaultsȱ
YES:ȱTheȱuserȱmustȱmanuallyȱconfirmȱtheȱrestoralȱofȱeachȱfaultȱtoȱaȱnormalȱcondition.ȱ
ThisȱisȱdoneȱviaȱtheȱUserȱmenuȱÆȱActivitiesȱÆȱAdvancedȱÆȱRestoreȱFaults.ȱ
NO:ȱTheȱrestoralȱreportȱofȱeachȱfaultȱisȱautomaticȱ.ȱ
YESȱ
ExitȱAlarmȱ
YES:ȱAȱviolatedȱzoneȱoutsideȱtheȱexitȱrouteȱwillȱgenerateȱanȱalarmȱduringȱtheȱexitȱtime.ȱAȱ
reportȱtoȱtheȱalarmȱreceivingȱcenterȱforȱsettingȱtheȱsystemȱisȱsentȱatȱtheȱbeginningȱofȱtheȱ
settingȱprocedure.ȱ
NO:ȱAȱviolatedȱzoneȱoutsideȱtheȱexitȱrouteȱwillȱcancelȱtheȱsettingȱprocess.ȱAȱreportȱtoȱtheȱ
alarmȱreceivingȱcenterȱisȱsendȱatȱtheȱendȱofȱaȱsuccessfulȱsettingȱprocedure.ȱ
EntryȱDelayedȱAlarmȱ
NOȱ
ThisȱfeatureȱisȱusedȱtoȱreduceȱfalseȱalarmȱreportsȱtoȱtheȱARC.ȱȱ
YES:ȱTheȱreportȱtoȱtheȱARCȱandȱtheȱsounderȱalarmȱwillȱbeȱdelayedȱforȱ30ȱsecondsȱorȱuntilȱ
theȱendȱofȱtheȱpredefinedȱentryȱdelayȱ(theȱshorterȱtimeȱofȱtheȱtwo)ȱfollowingȱaȱviolationȱofȱ
aȱzoneȱoutsideȱtheȱentryȱroute.ȱȱȱ
NO:ȱAȱviolatedȱzoneȱoutsideȱtheȱentryȱrouteȱwillȱgenerateȱanȱalarmȱduringȱtheȱ
entryȱtimeȱandȱaȱreportȱwillȱbeȱsentȱtoȱtheȱARC.
Page 4-11
AgilityȱEngineerȱManualȱ
ȱ
System: Controls
Parameter
Default
NOȱ
20ȱMinutesȱSignalȱ
YES:ȱPriorȱtoȱsettingȱtheȱsystem,ȱtheȱsystemȱwillȱcheckȱforȱzonesȱthatȱdidȱnotȱsendȱaȱsignalȱ
forȱmoreȱthanȱ20ȱminutes.ȱTheseȱzonesȱwillȱbeȱregardedȱasȱnotȱready.ȱAȱpartitionȱassignedȱ
withȱaȱnotȱreadyȱzoneȱcannotȱbeȱset.ȱȱ
NO:ȱPriorȱtoȱsetting,ȱtheȱsystemȱwillȱnotȱcheckȱwhetherȱaȱzoneȱdidȱnotȱsendȱaȱsignalȱforȱ
moreȱthanȱ20ȱminutes.ȱ
NOȱ
Attenuationȱ
YES:ȱTheȱAgilityȱreceiverȱwillȱbeȱattenuatedȱbyȱ6ȱdBȱduringȱtheȱcommunicationȱtest.ȱ
NO:ȱTheȱAgilityȱreceiverȱworksȱinȱnormalȱoperationȱmode.ȱ
DD243ȱprogrammingȱ
YESȱ
OmitȱExit/Entryȱ
YES:ȱItȱisȱpossibleȱforȱtheȱuserȱtoȱomitȱanȱExit/Entryȱzone.ȱ
NO:ȱAnȱExit/Entryȱzoneȱcannotȱbeȱomitted.ȱ
NOȱ
EntryȱDisableȱ
YES:ȱTheȱalarmȱconfirmationȱprocessȱwillȱbeȱdisabledȱwhenȱtheȱentryȱtimeȱstarts.ȱ
NO:ȱTheȱalarmȱconfirmationȱprocessȱwillȱstartȱwhenȱtheȱentryȱtimeȱstarts.ȱ
NOȱ
RouteȱDisableȱ
YES:ȱTheȱpanelȱdisablesȱtheȱentryȱrouteȱzonesȱ(EX/EN,ȱEXȱ(OP)/EN,ȱfollowersȱandȱFinalȱ
Exit)ȱfromȱparticipatingȱinȱtheȱalarmȱconfirmationȱprocessȱwhenȱtheȱentryȱtimeȱstarts.ȱ
Note:ȱSequentialȱconfirmationȱcanȱstillȱbeȱestablishedȱfromȱtwoȱconfirmedȱzones,ȱlocatedȱoffȱtheȱentryȱroute.ȱ
NO:ȱTheȱentryȱrouteȱzonesȱwillȱparticipateȱinȱtheȱalarmȱconfirmationȱprocessȱwhenȱtheȱ
entryȱtimeȱstarts.ȱ
NOȱ
EngineerȱResetȱConfirmationȱ
YES:ȱAnȱengineerȱresetȱconfirmationȱisȱrequiredȱinȱorderȱtoȱresetȱtheȱsystemȱafterȱaȱ
confirmedȱalarm.ȱTheȱsystemȱcannotȱbeȱsetȱuntilȱanȱEngineerȱResetȱConfirmationȱisȱ
performed.ȱTheȱresetȱcanȱbeȱdoneȱbyȱenteringȱtheȱAntiȱcodeȱorȱenteringȱtheȱinstallationȱ
modeȱorȱbyȱperformingȱaȱ“Engineerȱreset”ȱfromȱtheȱkeypad.ȱ
NO:ȱAnyȱmeansȱcanȱbeȱusedȱtoȱsetȱorȱunsetȱtheȱsystemȱ(keypad,ȱremoteȱphoneȱoperationȱ
etc.).ȱ
Page 4-12
AgilityȱEngineerȱManualȱ
ȱ
ȱ
System: Controls
Parameter
Default
NOȱ
KeyȱSwitchȱLockȱ
YES:ȱOnlyȱaȱLatchedȱKeyȱSwitchȱzoneȱcanȱsetȱorȱunsetȱtheȱsystem.ȱ
Note:ȱWhenȱtheȱsystemȱhasȱmoreȱthanȱ1ȱzoneȱdefinedȱasȱLatchȱKeyȱSwitch,ȱtheȱset/unsetȱoperationȱwillȱ
occurȱonlyȱafterȱallȱtheseȱzonesȱareȱsetȱorȱunset.ȱ
NO:ȱAnyȱmeansȱcanȱbeȱusedȱtoȱsetȱorȱunsetȱtheȱsystemȱ(keypad,ȱremoteȱphoneȱoperationȱ
etc.).ȱ
NOȱ
EntryȱUnsetȱ
Determinesȱifȱtheȱsystem’sȱunsettingȱdependsȱonȱtheȱentryȱtime.ȱ
YES:ȱOnlyȱaȱremoteȱcontrolȱcanȱunsetȱtheȱsystemȱduringȱentryȱtime.ȱȱ
Note:ȱTheȱsystemȱcanȇtȱbeȱunsetȱwithȱaȱremoteȱcontrolȱwhileȱtheȱsystemȱisȱset.ȱ
NO:ȱTheȱsystemȱcanȱbeȱunsetȱduringȱanyȱtimeȱusingȱanyȱunsettingȱdevice.ȱ
ȱ
CPȬ01ȱprogrammingȱ
NOȱ
ExitȱRestartȱ
Thisȱparameterȱisȱusedȱtoȱdefineȱifȱanȱexitȱtimeȱshallȱrestartȱoneȱadditionalȱtimeȱwhileȱanȱ
entry/exitȱzoneȱisȱtrippedȱtwiceȱduringȱexitȱtime.ȱȱ
YES:ȱExitȱtimeȱwillȱrestartȱforȱoneȱtimeȱonlyȱwhenȱanȱentry/exitȱzoneȱisȱtrippedȱduringȱ
exitȱtime.ȱ
NO:ȱExitȱtimeȱwillȱnotȱbeȱaffectedȱifȱanȱentry/exitȱzoneȱisȱtrippedȱduringȱexitȱtime.ȱ
NOȱ
AutoȱStayȱ
Thisȱparameterȱisȱusedȱtoȱdefineȱtheȱsystemȇsȱarmingȱmodeȱwhenȱusingȱaȱkeypadȱandȱnoȱ
exit/entryȱzoneȱisȱtrippedȱduringȱexitȱmode.ȱȱȱ
YES:ȱIfȱnoȱexit/entryȱzoneȱisȱtrippedȱduringȱexitȱtimeȱtheȱsystemȱwillȱbeȱarmedȱinȱSTAYȱ
mode.ȱ
NO:ȱIfȱnoȱexit/entryȱzoneȱisȱtrippedȱduringȱexitȱtimeȱtheȱsystemȱwillȱbeȱarmedȱinȱAwayȱ
mode.ȱȱȱ
Page 4-13
AgilityȱEngineerȱManualȱ
ȱ
System: Controls
Parameter
Default
ExitȱErrorȱ
NOȱ
ThisȱparameterȱisȱusedȱtoȱdefineȱwhatȱwillȱhappenȱifȱanȱExit/Entryȱzoneȱisȱleftȱopenȱatȱtheȱ
endȱofȱtheȱexitȱtime.ȱȱȱ
YES:ȱȱ
Œ
Localȱalarmȱwillȱbeȱactivatedȱatȱtheȱendȱofȱtheȱexitȱtime.ȱȱ
Œ
ExitȱerrorȱreportȱwillȱbeȱsentȱtoȱtheȱARCȱtogetherȱwithȱanȱalarmȱreportȱifȱtheȱsystemȱ
hasȱnotȱbeenȱdisarmedȱduringȱtheȱentryȱtimeȱthatȱimmediatelyȱstartedȱafterȱtheȱexitȱ
timeȱexpiration.ȱ
NO:ȱȱ
Œ
Œ
Noȱlocalȱalarmȱwillȱbeȱactivatedȱatȱtheȱendȱofȱtheȱexitȱtime.ȱȱ
OnlyȱanȱalarmȱreportȱwillȱbeȱsentȱtoȱtheȱARCȱifȱtheȱsystemȱhasȱnotȱbeenȱdisarmedȱ
duringȱtheȱentryȱtimeȱthatȱimmediatelyȱstartedȱafterȱtheȱexitȱtimeȱexpirationȱ
NOȱ
3ȱMinuteȱBypassȱ
YES:ȱBypassesȱallȱzonesȱautomaticallyȱforȱ3ȱminutesȱwhenȱpowerȱisȱrestoredȱtoȱanȱ
ȈunpoweredȈȱsystem.ȱ
NO:ȱNoȱbypassingȱoccurs.ȱ
1.3 Labels
Youȱcanȱrenameȱtheȱlabelsȱthatȱidentifyȱtheȱsystemȱandȱpartitionsȱbyȱchangingȱtheȱdefaultȱ
labelsȱ(Partitionȱ1,ȱPartitionȱ2ȱandȱsoȱon)ȱto,ȱforȱexample,ȱTheȱJonesȇs,ȱSalesȱDept,ȱorȱ
MastrȱBedrȱasȱappropriate.ȱ
Labelsȱthatȱcanȱbeȱrenamed:ȱȱ
System: Labels
Parameter
Systemȱ
Default
ȱ
Range
SecurityȱSystemȱ
Anyȱ16ȱcharactersȱ
Partitionsȱ1ȱthroughȱ3ȱ
Anyȱ16ȱcharactersȱ
Editsȱtheȱglobalȱ(system)ȱlabelȱȱ
Partitionȱ1/2/3ȱ
ȱ
Editsȱpartitionȱlabelsȱ
ȱ
Page 4-14
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Toȱrenameȱlabelsȱusingȱtheȱkeypadȱkeysȱtoȱproduceȱcharactersȱseeȱtheȱtableȱbelow:ȱ
Key
Data Sequence
1ȱ
2ȱ
3ȱ
4ȱ
5ȱ
6ȱ
7ȱ
8ȱ
9ȱ
0ȱ
ȱ
1ȱȱȱȱȱ.ȱȱȱȱȱ,ȱȱȱȱȱȇȱȱȱȱȱ?ȱȱȱȱȱ!ȱȱȱȱȱȈȱȱȱȱȱ–ȱȱȱȱȱ(ȱȱȱȱȱ)ȱȱȱȱȱ@ȱȱȱȱȱ/ȱȱȱȱȱ:ȱȱȱȱȱ_ȱȱȱȱȱ+ȱȱȱȱȱ&ȱȱȱȱȱ*ȱȱȱȱȱ#ȱȱ
2ȱȱȱȱȱaȱȱȱȱȱbȱȱȱȱȱcȱȱȱȱȱAȱȱȱȱȱBȱȱȱȱȱCȱ
3ȱȱȱȱȱdȱȱȱȱȱeȱȱȱȱȱfȱȱȱȱȱDȱȱȱȱȱEȱȱȱȱȱFȱ
4ȱȱȱȱȱgȱȱȱȱȱhȱȱȱȱȱiȱȱȱȱȱGȱȱȱȱȱHȱȱȱȱȱIȱ
5ȱȱȱȱȱjȱȱȱȱȱȱkȱȱȱȱȱȱlȱȱȱȱȱJȱȱȱȱȱȱKȱȱȱȱȱLȱ
6ȱȱȱȱmȱȱȱȱȱnȱȱȱȱȱoȱȱȱȱMȱȱȱȱNȱȱȱȱȱOȱ
7ȱȱȱȱȱpȱȱȱȱȱqȱȱȱȱȱrȱȱȱȱȱȱsȱȱȱȱȱPȱȱȱȱȱȱQȱȱȱȱȱRȱȱȱȱȱSȱ
8ȱȱȱȱȱtȱȱȱȱȱȱuȱȱȱȱȱvȱȱȱȱȱTȱȱȱȱUȱȱȱȱȱȱVȱ
9ȱȱȱȱwȱȱȱȱȱxȱȱȱȱȱyȱȱȱȱȱzȱȱȱȱȱWȱȱȱȱȱXȱȱȱȱȱYȱȱȱȱȱZȱ
0ȱ
Useȱtheseȱkeysȱtoȱtoggleȱforwardsȱandȱbackwardsȱthroughȱallȱtheȱavailableȱ
characters.ȱ
ȱ
1.4 Sounds
TheȱSoundsȱmenuȱcontainsȱparametersȱthatȱenableȱyouȱtoȱsetȱtheȱsound(s)ȱthatȱwillȱbeȱ
producedȱbyȱtheȱsystemȱafterȱtheȱfollowingȱsystemȱevents:ȱȱ
System: Sounds
Parameter
TamperȱSoundȱ
Default
ȱ
Bell/SetȱSilence/Unsetȱ
Range
1ȱtoȱ6ȱ
Setsȱtheȱsound(s)ȱproducedȱbyȱaȱTamperȱviolationȱaccordingȱtoȱtheȱfollowingȱoptions:ȱ
Œ Silentȱ
Œ Bellȱ(External/Internalȱsounder)ȱ
Œ Buzzerȱ(mainȱunit)ȱ
Œ Bellȱ+ȱBuzzerȱ
Œ Bell/SȱBuzzer/U:ȱBellȱwhenȱsystemȱset,ȱBuzzerȱwhenȱsystemȱunsetȱ
Œ Bell/SȱS/Unset:ȱBellȱwhenȱsystemȱset,ȱSilenceȱwhenȱsystemȱunsetȱ
LocalȱSpeakerȱAlarmȱVolumeȱ
Levelȱ5ȱ
0Ȭ5ȱ
SetsȱtheȱmainȱunitȇsȱinternalȱspeakerȱAlarmȱvolume.ȱTheȱvolumeȱrangesȱbetweenȱ0ȱ(silent)ȱ
toȱ5ȱ(Maxȱvolume).ȱAfterȱsetting/changingȱtheȱvolume,ȱsoundȱwillȱbeȱemittedȱbyȱtheȱ
internalȱspeakerȱtoȱenableȱevaluationȱofȱtheȱselectedȱvolumeȱlevel.ȱ
LocalȱSpeakerȱSquawkȱVolumeȱ
Levelȱ5ȱ
0Ȭ5ȱ
SetsȱtheȱmainȱunitȇsȱinternalȱspeakerȱSquawkȱvolume.ȱTheȱvolumeȱrangesȱbetweenȱ0ȱ
(silent)ȱtoȱ5ȱ(Maxȱvolume).ȱAfterȱsetting/changingȱtheȱvolume,ȱsoundȱwillȱbeȱemittedȱbyȱ
theȱinternalȱspeakerȱtoȱenableȱevaluationȱofȱtheȱselectedȱvolumeȱlevel.ȱ
Page 4-15
AgilityȱEngineerȱManualȱ
ȱ
System: Sounds
Parameter
Default
Exit/EntryȱBeepsȱVolumeȱ
Levelȱ3ȱ
Range
0Ȭ5ȱ
DeterminesȱtheȱvolumeȱofȱtheȱbeepsȱsoundedȱfromȱtheȱmainȱunitȱduringȱtheȱExit/Entryȱ
times.ȱ
SpeakerȱMessagesȱVolumeȱ
Levelȱ2ȱ
0Ȭ4ȱ
DeterminesȱtheȱvolumeȱofȱtheȱmessagesȱsoundedȱfromȱtheȱmainȱunitȱorȱtheȱListenȬInȱandȱ
Talkȱunit.ȱ
1.5 Settings
Thisȱoptionȱallowsȱsettingȱtheȱsystemȱinȱcomplianceȱwithȱaȱspecificȱstandardization.ȱ
System: Settings
Parameter
Default
Range
DefaultȱPanelȱ
ȱ
ȱ
ȱ
Restoresȱprogrammingȱoptionsȱtoȱfactoryȱdefaults.ȱ
TheȱPanelȱDefaultȱoptionȱwillȱbeȱfollowedȱbyȱquestionsȱregardingȱtheȱdefaultsȱofȱtheȱlabelsȱ
andȱerasingȱwirelessȱdevices.ȱUseȱȱ
ȱtoȱselectȱyourȱoption.ȱȱ
EraseȱWirelessȱDeviceȱ
ȱ
ȱ
Eraseȱwirelessȱdevicesȱwithoutȱchangingȱtheȱsystemȱcurrentȱprogrammedȱparametersȱ.ȱ
Languageȱ
Setsȱtheȱsystemȱlanguageȱ(Email,ȱSMSȱandȱkeypadȱlanguage)ȱ
Standardsȱ
ENȱ50131ȱ
NOȱ
ȱ
SetsȱtheȱpanelȱprogrammingȱoptionsȱinȱcomplianceȱwithȱENȱstandards.ȱ(Seeȱ
AppendixȱD)ȱ
DD243ȱ
NOȱ
ȱ
SetsȱtheȱpanelȱprogrammingȱoptionsȱinȱcomplianceȱwithȱDD243ȱstandards.ȱ
CPȬ01ȱ
NOȱ
ȱ
SetsȱtheȱpanelȱprogrammingȱoptionsȱinȱcomplianceȱwithȱCPȬ01ȱstandards.ȱ
Page 4-16
AgilityȱEngineerȱManualȱ
ȱ
ȱ
1.6 Service Information
TheȱServiceȱInformationȱmenuȱenablesȱyouȱtoȱinsertȱinformationȱaccessibleȱtoȱtheȱsystemȇsȱ
usersȱofȱtheȱalarmȱcompanyȱfromȱwhomȱtheȱserviceȱisȱobtained.ȱȱ
System: Service Information
Parameter
Default
Range
Nameȱ
ȱ
Anyȱ16ȱcharactersȱȱ
Enablesȱyouȱtoȱinsertȱand/orȱeditȱtheȱnameȱofȱtheȱalarmȱcompanyȱfromȱwhomȱserviceȱ
mayȱbeȱobtained.ȱTheȱinformationȱcanȱbeȱviewedȱbyȱtheȱuserȱusingȱtheȱwirelessȱkeypad.ȱȱȱ
Phoneȱ
ȱ
Anyȱ16ȱcharactersȱ
Enablesȱyouȱtoȱinsertȱand/orȱeditȱtheȱserviceȱphoneȱnumber.ȱTheȱinformationȱcanȱbeȱ
viewedȱbyȱtheȱuserȱusingȱtheȱwirelessȱkeypadȱ
1.7 Firmware Update
TheȱAgilityȱenablesȱyouȱtoȱremotelyȱupgradeȱtheȱmainȱunitȱfirmwareȱversionsȱviaȱIPȱorȱ
GPRSȱchannels.ȱUnderȱtheȱFirmwareȱUpdateȱmenuȱyouȱneedȱtoȱdefineȱtheȱlocationȱofȱtheȱ
upgradeȱfile.ȱȱTheȱrequestȱtoȱstartȱtheȱremoteȱupgradeȱcanȱbeȱdoneȱfromȱtheȱAgilityȱkeypadȱ
orȱfromȱtheȱAgilityȱConfigurationȱSoftware.ȱForȱdetailedȱinformationȱreferȱtoȱtheȱRemoteȱ
SoftwareȱUpgradeȱinstructionȱguide.ȱ
System: Firmware Update
Parameter
Default
Range
ServerȱIPȱ
192.114.175.43ȱ ȱ
EnterȱtheȱIPȱaddressȱofȱtheȱrouter/gatewayȱwhereȱtheȱupgradeȱfileȱisȱlocated.ȱȱ
ServerȱPortȱ
80ȱ
ȱ
Enterȱtheȱportȱonȱtheȱrouter/gatewayȱwhereȱtheȱupgradeȱfileȱisȱlocated.ȱ
FileȱPathȱ
ȱ
Enterȱtheȱupgradeȱfileȱname.ȱForȱexample:ȱ/Agility/0UK/cpcp.binȱ
PleaseȱcontactȱCustomerȱSupportȱservicesȱforȱtheȱfileȱnameȱparameters.ȱ
Page 4-17
ȱ
AgilityȱEngineerȱManualȱ
ȱ
2. Programming: Radio Devices Menu
TheȱRadioȱDevicesȱmenuȱprovidesȱaccessȱtoȱsubȬmenusȱthatȱareȱusedȱforȱprogramming,ȱ
definingȱandȱeditingȱeachȱofȱtheȱsystemȇsȱwirelessȱdevices.ȱTheȱRadioȱDevicesȱmenuȱisȱ
dividedȱintoȱtheȱfollowingȱsubȬmenus:ȱ
1.ȱAllocationȱ
2.ȱModificationȱ
3.ȱIdentificationȱ
2.1 Allocation
Eachȱwirelessȱdeviceȱmustȱbeȱidentifiedȱtoȱtheȱsystemȱreceiverȱbeforeȱitsȱparametersȱcanȱbeȱ
configured.ȱSeeȱChapterȱ3ȱforȱfurtherȱinformationȱonȱtheȱallocationȱprocedures.ȱ
2.2 Modification
Theȱmodificationȱmenuȱisȱusedȱtoȱchangeȱtheȱvaluesȱofȱtheȱparametersȱconfiguredȱbyȱtheȱ
systemȱforȱeachȱwirelessȱdevice.ȱTheȱmodificationȱmenuȱisȱdividedȱintoȱtheȱfollowingȱ
submenus:ȱ
1.ȱZonesȱ
2.ȱRemoteȱControlsȱ(Keyfobs)ȱ
3.ȱKeypadsȱ
4.ȱSoundersȱ
5.ȱI/OȱModulesȱȱ
Note:ȱThisȱlistȱvariesȱaccordingȱtoȱtheȱdevicesȱthatȱhaveȱbeenȱallocatedȱtoȱtheȱsystem.ȱOnlyȱ
devicesȱthatȱhaveȱbeenȱallocatedȱcanȱbeȱconfiguredȱorȱmodifiedȱbyȱtheȱengineer.ȱ
2.2.1 Zones
TheȱZonesȱmenuȱisȱdividedȱintoȱtheȱfollowingȱsubȬmenus:ȱ
Parametersȱ
Alarmȱ(Sequential)ȱConfirmationȱȱ
SoakȱTestȱ
ZoneȱPairingȱȱ
Parametersȱ
Note:ȱTheȱparametersȱdisplayed,ȱvaryȱaccordingȱtoȱtheȱtypeȱofȱzonesȱconnectedȱtoȱtheȱ
system.ȱ
Zones: Parameters
Parameter
Default
Labelȱ
Zoneȱ01/02/03/ȱ…ȱ
Aȱlabelȱidentifiesȱtheȱzoneȱinȱtheȱsystem.ȱUpȱtoȱ16ȱcharacters).ȱȱ
Page 4-18
Range
Anyȱcharactersȱ
AgilityȱEngineerȱManualȱ
ȱ
Zones: Parameters
Parameter
Default
Range
SerialȱNumberȱ
TheȱinternalȱIDȱnumberȱofȱtheȱzone.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱIDȱnumber.ȱ
PlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱzone.ȱ
Partitionȱ
ȱ
ȱ
Theȱpartitionȱ(1ȱtoȱ3)ȱassignmentȱforȱeachȱzone.ȱ
Typeȱ
ȱ
Eachȱzoneȱcanȱbeȱdefinedȱasȱoneȱofȱtheȱfollowingȱtypes:ȱȱ
NotȱUsedȱ ȱ
ȱ
ȱ
Disablesȱaȱzone.ȱAllȱunusedȱzonesȱshouldȱbeȱgivenȱthisȱdesignation.ȱ
Exit/Entryȱ1ȱȱ
ȱ
ȱ
UsedȱforȱExit/Entryȱdoors.ȱViolatedȱExit/Entryȱzonesȱdoȱnotȱcauseȱanȱintrusionȱ
alarmȱduringȱtheȱExit/EntryȱDelay.ȱIfȱtheȱzoneȱisȱnotȱsecuredȱbyȱtheȱendȱtheȱ
delayȱexpiresȱitȱwillȱtriggerȱanȱintrusionȱalarm.ȱȱ
Toȱstartȱaȱsettingȱprocess,ȱthisȱzoneȱshouldȱbeȱsecured.ȱWhenȱsystemȱisȱset,ȱthisȱ
zoneȱstartsȱtheȱentryȱdelayȱtime.ȱȱ
Exit/Entryȱ2ȱȱ
ȱ
ȱ
Sameȱasȱabove,ȱexceptȱthatȱtheȱExit/Entryȱ2ȱtimeȱperiodȱapplies.ȱ
Exit(Op)/Entryȱ1ȱ ȱ
ȱ
ȱ
UsedȱforȱanȱExit/Entryȱdoor.ȱȱThisȱzoneȱbehavesȱasȱdescribedȱinȱtheȱExit/Entryȱ1ȱ
parameter,ȱshownȱabove,ȱexceptȱthat,ȱifȱfaulted,ȱtheȱsettingȱprocessȱisȱnotȱ
prevented.ȱToȱavoidȱanȱintrusionȱalarm,ȱitȱmustȱbeȱsecuredȱbeforeȱtheȱexpirationȱ
ofȱtheȱExitȱDelayȱperiod.ȱ
Exit(Op)/Entryȱ2ȱ
ȱ
ȱ
Sameȱasȱabove,ȱexceptȱthatȱtheȱExitȱ(Op)/Entryȱ2ȱtimeȱperiodȱapplies.ȱ
EntryȱFollowerȱ
ȱ
ȱ
Usuallyȱassignedȱtoȱmotionȱdetectorsȱandȱtoȱinteriorȱdoorsȱprotectingȱtheȱareaȱ
betweenȱtheȱentryȱdoorȱandȱtheȱsystem.ȱ
Thisȱzone(s)ȱcausesȱanȱimmediateȱintrusionȱalarmȱwhenȱviolatedȱunlessȱanȱ
Exit/Entryȱzoneȱwasȱviolatedȱfirst.ȱInȱthisȱcase,ȱEntryȱFollowerȱzone(s)ȱwillȱ
remainȱomittedȱuntilȱtheȱendȱofȱtheȱEntryȱDelayȱperiod.ȱ
Page 4-19
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Zones: Parameters
Parameter
Intruderȱ(Instant)ȱ
Default
Range
ȱ
ȱ
UsuallyȱintendedȱforȱnonȬexit/entryȱdoors,ȱwindowȱprotection,ȱshockȱdetection,ȱ
andȱmotionȱdetectors.ȱ
Causesȱanȱimmediateȱintrusionȱalarmȱifȱviolatedȱafterȱtheȱsystemȱisȱsetȱorȱduringȱ
theȱExitȱDelayȱtimeȱperiod.ȱ
WhenȱAutoȱSetȱandȱPreȬWarningȱareȱdefined,ȱtheȱinstantȱzoneȱwillȱbeȱsetȱatȱtheȱ
endȱofȱtheȱPreȬWarningȱtimeȱperiod.ȱ
Interiorȱ+ȱExit/Entryȱ1ȱ
ȱ
ȱ
UsedȱforȱExit/Entryȱdoors,ȱasȱfollows:ȱ
Œ
IfȱtheȱsystemȱisȱsetȱinȱtheȱFullȱSetȱmode,ȱtheȱzone(s)ȱprovideȱaȱdelayȱ
(specifiedȱbyȱExit/Entryȱ1)ȱallowingȱentryȱintoȱandȱexitȱfromȱaȱsetȱ
premises.ȱ
Œ
IfȱtheȱsystemȱisȱsetȱinȱtheȱPartȱSetȱmode,ȱtheȱzoneȱisȱomitted.ȱ
Interiorȱ+ȱExit/Entryȱ2ȱ
ȱ
ȱ
SameȱasȱtheȱIȱ+ȱExit/Entryȱ1ȱparameter,ȱdescribedȱabove,ȱbutȱtheȱExit/Entryȱ2ȱ
timeȱperiodȱisȱapplicable.ȱ
Interiorȱ+ȱExit(Op)/Entryȱ1ȱ
ȱ
ȱ
Usedȱforȱanȱexit/entryȱdoorȱthat,ȱforȱconvenience,ȱmayȱbeȱkeptȱopenȱwhenȱtheȱ
systemȱisȱbeingȱset,ȱasȱfollows:ȱ
Œ
InȱFullȱSetȱmodeȱbehavesȱasȱanȱExitȱ(Op)/Entryȱ1ȱzone.ȱ
Œ
InȱPartȱSetȱmode,ȱtheȱzoneȱwillȱbeȱomitted.ȱ
Interiorȱ+ȱExit(Op)/Entryȱ2ȱ
ȱ
ȱ
SameȱasȱtheȱIȱ+ȱExitȱ(Op)/Entryȱ1ȱparameter,ȱdescribedȱabove,ȱbutȱtheȱExit/Entryȱ
2ȱtimeȱperiodȱisȱapplicable.ȱ
Interiorȱ+ȱEntryȱFollowerȱ
ȱ
ȱ
Generallyȱusedȱforȱmotionȱdetectorsȱand/orȱinteriorȱdoorsȱȱ(forȱexample,ȱfoyer),ȱ
whichȱwouldȱhaveȱtoȱbeȱviolatedȱafterȱentryȱinȱorderȱtoȱunsetȱtheȱsystem,ȱasȱ
follows:ȱ
Œ
InȱFullȱsetȱmodeȱbehavesȱasȱanȱEntryȱFollowerȱzone.ȱ
Œ
InȱPartȱSetȱmode,ȱtheȱzoneȱwillȱbeȱomitted.ȱ
Interiorȱ+ȱIntruderȱ(Instant)ȱ
ȱ
ȱ
UsuallyȱintendedȱforȱnonȬexit/entryȱdoors,ȱwindowȱprotection,ȱshockȱdetectionȱ
andȱmotionȱdetectors.ȱ
Œ
InȱFullȱSetȱmodeȱbehavesȱasȱanȱIntruderȱ(instant)ȱzone.ȱ
Œ
InȱPartȱSetȱmode,ȱtheȱzoneȱisȱomitted.ȱ
Page 4-20
AgilityȱEngineerȱManualȱ
ȱ
Zones: Parameters
Parameter
EntryȱFollowerȱ+ȱPartȱSetȱ
Default
Range
ȱ
ȱ
Assignedȱtoȱmotionȱdetectorsȱandȱtoȱinteriorȱdoorsȱprotectingȱtheȱareaȱbetweenȱ
theȱentryȱdoorȱandȱtheȱkeypad,ȱasȱfollows:ȱȱ
Œ
InȱFullȱSetȱmodeȱbehavesȱlikeȱanȱEntryȱFollowerȱZone.ȱ
Œ
InȱPartȱSetȱmodeȱbehavesȱlikeȱanȱExit/Entryȱ1ȱzone.ȱȱ
24ȱHoursȱ
ȱ
ȱ
UsuallyȱassignedȱtoȱprotectȱnonȬmovableȱglass,ȱfixedȱskylights,ȱandȱcabinetsȱ
(possibly)ȱforȱshockȱdetectionȱsystems.ȱ
Aȱviolationȱofȱsuchȱaȱzoneȱcausesȱanȱinstantȱintrusionȱalarm,ȱregardlessȱofȱtheȱ
systemȇsȱstate.ȱ
Fireȱ
ȱ
ȱ
Forȱsmokeȱorȱotherȱtypesȱofȱfireȱdetectors.ȱThisȱoptionȱcanȱalsoȱbeȱusedȱforȱ
manuallyȱtriggeredȱpanicȱbuttonsȱorȱpullȱstationsȱ(ifȱpermitted),ȱasȱfollows:ȱ
Ifȱviolated,ȱitȱcausesȱanȱimmediateȱfireȱalarm,ȱfireȱreportȱtoȱtheȱalarmȱreceivingȱ
center.ȱ
Panicȱ
ȱ
ȱ
Usedȱforȱexternalȱpanicȱbuttonsȱandȱwirelessȱpanicȱtransmitters.ȱ
Ifȱviolated,ȱanȱimmediateȱpanicȱalarmȱisȱsoundedȱ(ifȱtheȱzoneȱsoundȱisȱnotȱ
definedȱasȱsilentȱorȱAudibleȱPanicȱsystemȱcontrolȱisȱenabled),ȱregardlessȱofȱtheȱ
systemȇsȱstateȱandȱpanicȱreportȱisȱsendȱtoȱtheȱalarmȱreceivingȱcenter.ȱAnȱalarmȱ
displayȱwillȱnotȱappearȱonȱtheȱkeypads.ȱ
Specialȱ
ȱ
ȱ
Forȱexternalȱauxiliaryȱemergencyȱalertȱbuttonsȱandȱwirelessȱauxiliaryȱemergencyȱ
transmitters.ȱ
Ifȱviolated,ȱanȱimmediateȱauxiliaryȱemergencyȱalarmȱisȱsounded,ȱregardlessȱofȱ
theȱsystemȇsȱstateȱandȱreportȱisȱsentȱtoȱtheȱalarmȱreceivingȱcenter.ȱ
Tamperȱȱ
ȱ
ȱ
Forȱtamperȱdetection.ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱzone,ȱbutȱitȱhasȱaȱ
specialȱreportingȱcode.ȱ
Note:ȱForȱthisȱzoneȱtypeȱtheȱzoneȱsoundȱisȱdeterminedȱaccordingȱtoȱtheȱTamperȱSoundȱdefinedȱ
underȱSystemȱÆȱSoundȱÆȱTamperȱ
Waterȱȱ(Flood)ȱ
ȱ
ȱ
Forȱfloodȱorȱotherȱtypesȱofȱwaterȱdetectors.ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱ
hoursȱzone,ȱbutȱitȱhasȱaȱspecialȱfloodȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱȱ
Page 4-21
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Zones: Parameters
Parameter
Gasȱ
Default
Range
ȱ
ȱ
ForȱGasȱ(naturalȱgas)ȱleakȱdetector.ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱ
zone,ȱbutȱitȱhasȱaȱspecialȱgasȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱ
COȱ
ȱ
ȱ
ForȱCOȱ(CarbonȱMonoxide)ȱgasȱdetectors.ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱ
hoursȱzone,ȱbutȱitȱhasȱaȱspecialȱCOȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱ
HighȱTemperatureȱ
ȱ
ȱ
Forȱdetectorȱtemperatureȱ(hotȱorȱcold).ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱ
zone,ȱbutȱitȱhasȱaȱspecialȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱ
LowȱTemperatureȱ
ȱ
ȱ
Forȱdetectorȱtemperatureȱ(hotȱorȱcold).ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱ
zone,ȱbutȱitȱhasȱaȱspecialȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱ
Technicalȱ
ȱ
ȱ
Thisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱzone,ȱitsȱȱreportȱcodeȱshouldȱbeȱ
manuallyȱsetȱaccordingȱtoȱtheȱrelevantȱdetectorȱconnectedȱtoȱtheȱzone.ȱȱ
FinalȱExitȱ
ȱ
ȱ
Zonesȱofȱthisȱtypeȱmustȱbeȱtheȱlastȱdetectorȱtoȱbeȱactivatedȱonȱexitȱorȱtheȱfirstȱ
detectorȱtoȱbeȱactivatedȱonȱentry.ȱ
Whenȱsettingȱtheȱsystem,ȱtheȱrelatedȱpartitionȱsetsȱ10ȱsecondsȱafterȱthisȱzoneȱisȱ
closed,ȱorȱopenedȱandȱthenȱclosed.ȱAfterȱitȱisȱtriggeredȱonce,ȱtheȱzoneȱactsȱasȱanȱ
exitȱ(open)/entryȱ1ȱzone.ȱ
ExitȱTerminationȱȱ
ȱ
ȱ
ThisȱtypeȱofȱzoneȱisȱusedȱtoȱavoidȱaȱfalseȱalarmȱbyȱactingȱlikeȱanȱExitȱ(OP)/Entryȱ
zone.ȱ
Whenȱtriggeredȱ(afterȱsettingȱtheȱsystemȱandȱclosingȱtheȱdoorȱorȱopeningȱtheȱ
door,ȱsettingȱtheȱsystem,ȱandȱclosingȱtheȱdoor),ȱtheȱsystemȇsȱExitȱDelayȱtimeȱ
periodȱwillȱbeȱshortenedȱtoȱ3ȱseconds.ȱ
WhenȱyouȱreȬopenȱtheȱdoor,ȱtheȱentryȱtimeȱrestarts.ȱ
POȱTriggerȱ
ȱ
ȱ
Forȱaȱdeviceȱorȱzone,ȱwhichȱifȱviolatedȱatȱanyȱtimeȱtriggersȱaȱpreviouslyȱ
programmedȱProgrammingȱOutput,ȱcapableȱofȱactivatingȱanȱexternalȱindicator,ȱ
relay,ȱappliance,ȱandȱsoȱon.ȱ
Page 4-22
AgilityȱEngineerȱManualȱ
ȱ
Zones: Parameters
Parameter
Dayȱ
Default
Range
ȱ
ȱ
Usuallyȱassignedȱtoȱanȱinfrequentlyȱusedȱdoor,ȱsuchȱasȱanȱemergencyȱdoorȱorȱaȱ
movableȱskylight.ȱUsedȱtoȱalertȱtheȱsystemȱuserȱifȱaȱviolationȱoccursȱduringȱtheȱ
unsetȱperiodȱ(faultȱbyȱday;ȱburglaryȱatȱnight),ȱasȱfollows:ȱ
Œ
Withȱtheȱsystemȱsetȱ(eitherȱFullȱSetȱorȱPartȱSet),ȱtheȱzoneȱactsȱasȱanȱ
instantȱzone.ȱAȱviolationȱofȱthisȱzoneȱafterȱtheȱsystemȱisȱsetȱorȱduringȱ
theȱExitȱDelayȱtimeȱperiodȱcausesȱanȱimmediateȱintrusionȱalarm.ȱ
Œ
Withȱtheȱsystemȱunset,ȱaȱviolationȱofȱthisȱzoneȱattemptsȱtoȱalertȱtheȱ
(Fault)ȱLEDȱtoȱflashȱrapidly.ȱThisȱdirectsȱtheȱ
userȱbyȱcausingȱtheȱ
userȱtoȱviewȱtheȱsystemȇsȱstatus.ȱ
Optionally,ȱsuchȱaȱviolationȱcanȱbeȱreportedȱtoȱtheȱARCȱasȱaȱZoneȱFault.ȱ
PulsedȱKeyȱSwitchȱ
ȱ
ȱ
Connectȱanȱexternalȱmomentaryȱactionȱkeyȱswitchȱtoȱanyȱzoneȱgivenȱthisȱ
designation.ȱThisȱzoneȱwillȱset/unsetȱtheȱpartitionsȱassignedȱtoȱit.ȱ
PulsedȱKeyȱSwitchȱDelayedȱ
ȱ
ȱ
UsedȱtoȱapplyȱtheȱExit/EntryȱDelayȱ1ȱparameterȱtoȱtheȱPulsedȱKeyȱSwitchȱzone.ȱ
LatchedȱKeyȱSwitchȱ
ȱ
ȱ
ConnectȱanȱexternalȱSPSTȱlatchedȱ(nonȬmomentary)ȱkeyȱswitchȱfollows:ȱ
Œ
Afterȱsettingȱoneȱorȱmoreȱpartitionsȱusingȱtheȱkeyȱswitchȱandȱthenȱ
unsettingȱusingȱtheȱkeypad,ȱtheȱrelatedȱpartitionsȱwillȱbeȱunset.ȱInȱ
orderȱtoȱsetȱtheȱpartitionȱusingȱtheȱkeyȱswitchȱagain,ȱturnȱtheȱkeyȱtoȱtheȱ
unsetȱpositionȱandȱthenȱtoȱtheȱsetȱposition.ȱȱ
Œ
Ifȱaȱkeyȱswitchȱlatchȱisȱassignedȱtoȱmoreȱthanȱoneȱpartitionȱandȱoneȱofȱ
theȱpartitionsȱisȱsetȱbyȱusingȱtheȱkeypadȱ(theȱkeyȱswitchȱstaysȱinȱtheȱ
unsetȱposition),ȱthen:ȱ
ȱȬȱWhenȱchangingȱtheȱpositionȱofȱtheȱkeyȱswitchȱtoȱtheȱsetȱposition,ȱallȱ
theȱunsetȱpartitions,ȱwhichȱbelongȱtoȱthisȱkeyȱswitch,ȱwillȱbeȱset.ȱ
ȱȬȱWhenȱturningȱtheȱkeyȱswitchȱtoȱtheȱunsetȱposition,ȱallȱtheȱpartitionsȱ
willȱbeȱunset.ȱ
LatchedȱKeyȱSwitchȱDelayȱ
ȱ
ȱ
UsedȱtoȱapplyȱtheȱExit/EntryȱDelayȱ1ȱparameterȱtoȱtheȱlatchedȱkeyȱswitchȱzone.ȱ
Soundȱ
Bellȱ
ȱ
Containsȱparametersȱthatȱenableȱyouȱtoȱprogramȱtheȱsoundȱproducedȱwhenȱaȱsystemȱ
zoneȱtriggersȱanȱalarmȱforȱtheȱtimeȱdefinedȱunderȱtheȱBellȱTimeȱOutȱparameter.ȱȱ
Silentȱȱ
ȱ
Producesȱnoȱsoundȱ
Page 4-23
ȱ
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Zones: Parameters
Parameter
Bellȱȱ
Default
Range
ȱ
ȱ
Activatesȱtheȱwirelessȱsoundersȱ(internalȱorȱexternal)ȱandȱalarmȱfromȱtheȱmainȱ
unitȱassignedȱtoȱtheȱpartitionsȱofȱtheȱzone.ȱ
Buzzerȱ(mainȱunit)ȱȱ
ȱ
ȱ
Activatesȱtheȱinternalȱbuzzerȱonȱtheȱmainȱunit.ȱȱ
Bellȱ+ȱBuzzerȱȱ
ȱ
ȱ
Activatesȱtheȱwirelessȱsoundersȱandȱsounderȱonȱtheȱmainȱunitȱsimultaneously.ȱ
Bell/SetȱBuzzer/Unsetȱȱ
ȱ
ȱ
Inȱaȱcaseȱofȱalarm,ȱtheȱfollowingȱoccurs:ȱ
Œ
InȱFullȱSetȱmodeȱtheȱwirelessȱsounderȱwillȱoperate.ȱ
Œ
InȱUnsetȱmode,ȱonlyȱtheȱbuzzerȱonȱtheȱmainȱunitȱwillȱoperate.ȱ
Advancedȱprogrammingȱ
ȱ
ȱ
Chimeȱȱ
Noneȱ
ȱ
TheȱChimeȱparameterȱisȱusedȱasȱanȱaudibleȱindicationȱtoȱaȱzoneȱviolationȱwhileȱtheȱ
systemȱisȱUnset.ȱDefineȱwhichȱsoundȱoccursȱwhenȱviolated:ȱ
Options:ȱ
Œ
Noneȱ
Œ
Buzzerȱ(Mainȱunit)ȱ
Œ
ChimeȱSoundȱ1ȱ
Œ
ChimeȱSoundȱ2ȱ
Œ
ChimeȱSoundȱ3ȱ
Œ
ZoneȱMessageȱ
Controlsȱ
Supervisionȱ
ȱ
ȱ
ȱ
ȱ
Chooseȱwhichȱzoneȱwillȱbeȱsupervisedȱbyȱtheȱsystemȱreceiverȱaccordingȱtoȱtheȱ
timeȱdefinedȱunderȱtheȱtimerȱRXȱSupervision.ȱ(Seeȱpageȱ4Ȭ4)ȱ
Page 4-24
AgilityȱEngineerȱManualȱ
ȱ
Zones: Parameters
Parameter
ForcedȱSettingȱY/Nȱ
Default
Range
ȱ
ȱ
Thisȱoptionȱenablesȱorȱdisablesȱtheȱuseȱofȱforcedȱsettingȱforȱeachȱofȱtheȱsystemȇsȱ
zones,ȱasȱfollows:ȱ
Œ Ifȱforcedȱsettingȱisȱenabledȱforȱaȱparticularȱzone,ȱitȱallowsȱtheȱsystemȱtoȱbeȱsetȱ
evenȱthoughȱthisȱzoneȱisȱfaulty.ȱ
Œ
Œ
Œ
Whenȱaȱzone(s)ȱenabledȱforȱforcedȱsettingȱisȱfaulted,ȱtheȱ ȱȱLEDȱblinksȱ
duringȱtheȱunsetȱperiod.ȱ
Afterȱsetting,ȱallȱzonesȱenabledȱforȱforcedȱsettingȱareȱomittedȱatȱtheȱendȱofȱtheȱ
ExitȱDelayȱtimeȱperiod.ȱ
Ifȱaȱfaultedȱzoneȱ(oneȱenabledȱforȱforceȱsetting)ȱisȱsecuredȱduringȱtheȱsetȱ
period,ȱitȱwillȱnoȱlongerȱbeȱomittedȱandȱwillȱbeȱincludedȱamongȱtheȱsystemȇsȱ
setȱzones.ȱȱ
NoȱActivityȱȱ
ȱ
Y/Nȱ
DeterminesȱwhetherȱtheȱzoneȱparticipatesȱinȱtheȱNoȱActivityȱfunction.ȱTheȱNoȱ
Activityȱfunctionȱisȱforȱreceptionȱofȱsignalsȱusedȱtoȱmonitorȱtheȱactivityȱofȱsick,ȱ
elderlyȱorȱdisabledȱpeople.ȱSeeȱTimerȱȈNoȱActivityȈȱonȱpageȱ4Ȭ4.ȱ
LEDȱEnableȱY/Nȱ(Onlyȱforȱ2ȱWayȱPIRȱandȱ2ȱWayȱWatchOUT)ȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ
Y/Nȱ
DefinesȱtheȱLEDȱoperationȱmode.ȱ
Yes:ȱDetectorȇsȱLEDȱactivatedȱ
No:ȱDetectorȇsȱLEDȱdeactivatedȱ
AbortȱAlarmȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ
Y/Nȱ
ThisȱparameterȱdefinesȱwhetherȱaȱzoneȱalarmȱreportȱtoȱtheȱAlarmȱReceivingȱ
Centerȱwillȱbeȱimmediateȱorȱdelayed:ȱȱ
YES:ȱAȱreportȱtoȱtheȱARCȱwillȱbeȱdelayedȱaccordingȱtoȱtheȱAbortȱTimeȱDelayȱ
parameterȱ(CommunicationÆȱARCȱÆȱARCȱTimesÆAbortȱAlarm).ȱȱȱ
Note:ȱIfȱaȱvalidȱUserȱCodeȱisȱenteredȱtoȱresetȱtheȱalarmȱwithinȱtheȱcancelȱdelayȱtimeȱ
(CommunicationÆARCÆȱARCȱTimesÆCancelȱReport),ȱaȱcancelȱreportȱalarmȱcodeȱwillȱbeȱ
sentȱtoȱtheȱARC.ȱ
NO:ȱAȱreportȱtoȱtheȱMSȱwillȱbeȱsentȱimmediately.ȱȱ
DetectionȱModeȱ(Onlyȱforȱ2ȱWayȱDetectors)ȱ
Œ
Œ
Normalȱ
Fastȱ(WalkȱTest):ȱWhenȱtheȱdetectorȱisȱinȱdisarmȱitȱwillȱtransmitȱafterȱeachȱdetectionȱȱ
Normalȱ(Default):ȱWhenȱtheȱdetectorȱisȱinȱdisarm,ȱthereȱwillȱbeȱ2.5ȱminutesȱdeadȱtimeȱ
betweenȱdetectionȱtransmissions
Note:ȱForȱbothȱoptions,ȱwhenȱtheȱdetectorȱisȱarmedȱitȱwillȱtransmitȱafterȱeachȱdetection.ȱ
Page 4-25
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Zones: Parameters
Parameter
Default
Range
Sensitivityȱ(Onlyȱforȱ2ȱWayȱPIRȱandȱ2ȱWayȱWatchOUT)ȱ
ȱ
ȱ
DefinesȱtheȱPIRȱSensitivityȱofȱtheȱdetector.ȱ
Œ
Lowȱ
Œ
Mediumȱ(2ȱWayȱWatchOUT)ȱ
Œ
Highȱ
Œ
Maximumȱ(2ȱWayȱWatchOUT)ȱ
AlarmȱConfirmationȱ
TheȱAlarmȱConfirmationȱmenuȱenablesȱtoȱdefineȱprotectionȱagainstȱfalseȱalarmsȱandȱwillȱ
beȱusedȱforȱalarmȱverification.
Zones: Alarm Confirmation
Parameter
Default
Range
ConfirmȱPartitionȱȱ
ȱ
ȱ
Definesȱwhichȱpartitionsȱwillȱbeȱdefinedȱforȱalarmȱsequentialȱconfirmation.ȱ
Eachȱconfirmedȱpartitionȱhasȱaȱseparateȱtimer,ȱwhichȱisȱequivalentȱtoȱtheȱconfirmationȱ
timeȱdefinedȱinȱ“ConfirmationȱTimeȱWindow”.ȱ
Aȱconfirmedȱintruderȱalarmȱwillȱbeȱreportedȱifȱtwoȱseparateȱalarmȱconditionsȱareȱ
detectedȱinȱtheȱsameȱconfirmedȱpartition,ȱduringȱtheȱconfirmationȱtime.ȱ
ConfirmȱZonesȱȱ
ȱ
ȱ
Defineȱwhichȱzonesȱwillȱbeȱdefinedȱforȱalarmȱsequentialȱconfirmation.ȱȱ
Whenȱtheȱfirstȱzoneȱgoesȱintoȱalarmȱtheȱsystemȱtransmitsȱtheȱfirstȱzoneȱalarm.ȱWhenȱtheȱ
secondȱzoneȱgoesȱintoȱalarm,ȱduringȱtheȱconfirmationȱtime,ȱtheȱpanelȱtransmitsȱtheȱzoneȱ
alarmȱandȱtheȱPoliceȱcode.ȱ
Notes:ȱȱȱ
1.ȱAȱconfirmedȱzoneȱwillȱbeȱpartȱofȱtheȱsequentialȱconfirmationȱonlyȱifȱtheȱpartitionȱinȱwhichȱtheȱalarmȱ
occursȱisȱdefinedȱasȱconfirmedȱpartitionȱasȱwell.ȱ
2.ȱAnyȱCodeȱcanȱresetȱaȱconfirmedȱalarm.ȱȱ
3.ȱIfȱtheȱfirstȱzoneȱisȱviolatedȱandȱnotȱrestoredȱuntilȱtheȱendȱofȱtheȱconfirmationȱtimeȱ(noȱsecondȱzoneȱ
alarm),ȱthanȱthisȱzoneȱwillȱbeȱexcludedȱfromȱtheȱconfirmationȱprocessȱuntilȱtheȱnextȱsetting.ȱȱȱ
SoakȱTestȱ
TheȱSoakȱTestȱfeatureȱisȱdesignedȱtoȱallowȱfalseȱalarmingȱforȱpredefinedȱdetectorsȱtoȱbeȱ
omittedȱfromȱtheȱsystem,ȱwhileȱanyȱalarmsȱgeneratedȱareȱdisplayedȱtoȱtheȱuserȱforȱ
reportingȱtoȱtheȱARC.ȱThisȱisȱespeciallyȱusefulȱifȱPoliceȱresponseȱwithdrawalȱisȱbeingȱ
threatenedȱandȱaȱparticularȱzoneȱisȱcausingȱunidentifiedȱproblems.ȱ
Page 4-26
AgilityȱEngineerȱManualȱ
ȱ
EachȱzoneȱcanȱbeȱplacedȱonȱSoakȱTest.ȱAnyȱzoneȱplacedȱinȱtheȱSoakȱTestȱlistȱisȱomittedȱ
fromȱtheȱsystemȱforȱ14ȱdaysȱandȱisȱautomaticallyȱreinstatedȱafterȱthatȱtimeȱifȱNOȱalarmsȱ
haveȱbeenȱgeneratedȱbyȱit.ȱ
IfȱaȱzoneȱinȱtheȱSoakȱTestȱlistȱhasȱanȱalarmȱduringȱtheȱ14Ȭdayȱperiod,ȱtheȱkeypadȱindicatesȱ
toȱtheȱuserȱthatȱtheȱtestȱhasȱfailed.ȱAfterȱtheȱuserȱlooksȱatȱtheȱViewȱFaultȱoption,ȱtheȱfaultȱ
messageȱwillȱbeȱerased.ȱThisȱwillȱbeȱindicatedȱinȱtheȱeventȱlog,ȱbutȱnoȱalarmȱwillȱbeȱ
generated.ȱTheȱalarmedȱzoneȇsȱ14ȬdayȱSoakȱTestȱperiodȱisȱthenȱresetȱandȱrestarted.ȱ
ZoneȱPairingȱȱ
TheȱZoneȱPairingȱmenuȱisȱusedȱforȱadditionalȱprotectionȱfromȱfalseȱalarmsȱandȱcontainsȱ
parametersȱthatȱenableȱyouȱtoȱlinkȱtogetherȱtwoȱrelatedȱzones.ȱBothȱmustȱbeȱviolatedȱ
withinȱaȱdesignatedȱtimeȱperiodȱ(betweenȱ1ȱandȱ9ȱminutes)ȱbeforeȱanȱalarmȱoccurs.ȱ
ThisȱtypeȱofȱlinkingȱisȱusedȱwithȱmotionȱdetectorsȱinȱhostileȱorȱfalseȬalarmȱproneȱ
environments. Default:ȱNoȱcrossȱzoning
Zones: Zone Pairing
Parameter
1stȱZoneȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Theȱ1stȱzoneȱofȱaȱpairȱofȱzoneȱdefinedȱforȱzoneȱcrossings.ȱ
2ndȱZoneȱ
Theȱ2ndȱzoneȱofȱaȱpairȱofȱzoneȱdefinedȱforȱzoneȱcrossings.ȱ
Timeȱ
Theȱamountȱofȱtimeȱallowedȱbetweenȱtheȱtriggeringȱeventsȱforȱbothȱzonesȱtoȱbeȱ
consideredȱaȱvalidȱviolationȱ
CorrelationȱTypeȱ
ȱ
ȱ
DetermineȱhowȱtheȱAgilityȱwillȱprocessȱviolationsȱofȱtheȱpairedȱzones.ȱȱ
™ Notȱcorrelateȱ(None):ȱTemporarilyȱdisablesȱanyȱassociatedȱzoneȱpairingsȱ
™ Orderedȱcorrelate:ȱEffectsȱanȱalarmȱsoȱtheȱfirstȱlistedȱzoneȱisȱtrippedȱbeforeȱtheȱ
secondȱ
™ Notȱorderedȱcorrelate:ȱAffectsȱanȱalarmȱinȱwhichȱeitherȱzoneȱinȱtheȱpairȱmayȱbeȱ
trippedȱfirst.ȱIfȱthisȱcase,ȱtheȱspecifiedȱzoneȱorderȱ(1st,ȱ2nd)ȱhasȱnoȱbearingȱonȱ
theȱalarmȱactivation.ȱ
Note:ȱZonesȱcrossedȱwithinȱthemselvesȱareȱvalidȱpairs.ȱTheyȱneedȱtoȱregisterȱaȱviolationȱtwiceȱtoȱtriggerȱtheȱ
ȱ
alarm.ȱThisȱprocessȱisȱknownȱasȱDoubleȱKnock.ȱ
Page 4-27
ȱ
AgilityȱEngineerȱManualȱ
ȱ
2.2.2 Remote Controls
TheȱRemoteȱControlsȱmenuȱdefinesȱtheȱoperationȱofȱtheȱremoteȱcontrols.ȱUpȱtoȱ8ȱremoteȱ
controlsȱcanȱbeȱassignedȱtoȱtheȱsystem.ȱTheȱsystemȱsupportsȱ2ȱtypesȱofȱremoteȱcontrols:ȱ
OneȱWayȱRemoteȱControlsȱ(4ȱbutton)ȱȱ
TwoȱWayȱ(bidirectional)ȱRemoteȱControlsȱ(8ȱbutton)ȱ
Parametersȱ
Theȱprogrammingȱoptionsȱunderȱtheȱparametersȱmenuȱvaryȱaccordingȱtoȱtheȱtypeȱofȱtheȱ
remoteȱcontrol.ȱȱ
OneȱWayȱRemoteȱControlȱParametersȱ
Eachȱoneȱwayȱremoteȱcontrolȱconsistsȱofȱ4ȱbuttons,ȱandȱeachȱbuttonȱcanȱbeȱprogrammedȱtoȱ
aȱdifferentȱmodeȱofȱoperation.ȱ
Remote Controls Parameters: One Way Remote Controls
Parameter
Labelȱ
ȱ
ȱ
ȱ
ȱ
Aȱlabelȱidentifyingȱtheȱuserȱofȱtheȱremoteȱcontrol.ȱȱ
SerialȱNumberȱ
TheȱinternalȱIDȱnumberȱofȱtheȱremoteȱcontrol.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱ
serialȱnumber.ȱPlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱremoteȱcontrol.ȱ
Partitionȱ
ȱ
ȱ
ȱ
ȱ
Assignȱtheȱrelevantȱpartitionsȱforȱtheȱselectedȱremoteȱcontrol.ȱ
Buttonȱ1ȱ(±)ȱ
Setȱtheȱoperationȱofȱbuttonȱ1ȱofȱtheȱremoteȱcontrolȱfromȱtheȱfollowingȱoptions:ȱ
Œ
None:ȱButtonȱdisabled.ȱ
Œ
Set:ȱTheȱbuttonȱisȱusedȱforȱFullȱsettingȱofȱtheȱremoteȱcontrolȇsȱpartitions.ȱȱ
Œ
PartȱSet:ȱTheȱbuttonȱisȱusedȱforȱPartȱSettingȱofȱtheȱremoteȱcontrolȇsȱpartitions.ȱ
Buttonȱ2ȱ(²)ȱ
ȱ
ȱ
Setȱtheȱoperationȱofȱbuttonȱ2ȱofȱtheȱremoteȱcontrolȱfromȱtheȱfollowingȱoptions:ȱ
Œ
None:ȱButtonȱdisabled.ȱ
Œ
Unset:ȱTheȱbuttonȱisȱusedȱforȱunsettingȱitsȱassignedȱpartitions.ȱ
Buttonȱ3ȱ
ȱ
ȱ
Setȱtheȱoperationȱofȱbuttonȱ3ȱ(Smallȱblankȱbutton)ȱofȱtheȱremoteȱcontrolȱfromȱtheȱ
followingȱoptions:ȱ
Œ
None:ȱButtonȱdisabled.ȱ
Œ
Panic:ȱTheȱbuttonȱisȱusedȱtoȱsendȱaȱpanicȱalarm.ȱ
Œ
POȱControlȱ(1Ȭ20):ȱTheȱbuttonȱisȱusedȱtoȱoperateȱaȱsingleȱProgrammingȱOutput.ȱ
Page 4-28
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Remote Controls Parameters: One Way Remote Controls
Parameter
Buttonȱ4ȱ
ȱ
ȱ
Setȱtheȱoperationȱofȱbuttonȱ4ȱ(Largeȱblankȱbutton)ȱofȱtheȱremoteȱcontrolȱfromȱtheȱ
followingȱoptions:ȱ
Œ
None:ȱButtonȱdisabled.ȱ
Œ
Set:ȱTheȱbuttonȱisȱusedȱforȱFullȱsettingȱofȱtheȱremoteȱcontrolȇsȱpartitions.ȱȱ
Œ
PartȱSet:ȱTheȱbuttonȱisȱusedȱforȱPartȱSettingȱofȱtheȱremoteȱcontrolȇsȱpartitions.ȱȱ
Œ
POȱControlȱ(1Ȭ20):ȱTheȱbuttonȱisȱusedȱtoȱoperateȱaȱProgrammingȱOutput.ȱ
ȱ
TwoȱWayȱBiȬdirectionalȱRemoteȱControlsȱ
Theȱbiȱdirectionalȱremoteȱcontrolȱisȱanȱ8ȱbuttonȱrollingȱcodeȱwirelessȱtransmitterȱdesignedȱ
forȱremoteȱsystemȱoperation.ȱBeingȱbiȬdirectionalȱenablesȱeachȱcommandȱthatȱisȱsentȱtoȱtheȱ
panelȱtoȱreceiveȱaȱreplyȱstatusȱindicationȱbackȱfromȱtheȱpanelȱusingȱitsȱ3ȱcolorȱLEDsȱandȱ
internalȱbuzzerȱsounder.ȱȱForȱhigherȱsecurity,ȱcommandsȱcanȱbeȱdefinedȱtoȱbeȱactivatedȱ
withȱaȱ4ȱdigitȱPINȱcode.ȱ
Remote Controls Parameters: 2 Way Remote Control
Parameter
Labelȱ
ȱ
ȱ
Aȱlabelȱidentifyingȱtheȱuserȱofȱtheȱremoteȱcontrol.ȱȱ
SerialȱCodeȱ
TheȱinternalȱIDȱnumberȱofȱtheȱremoteȱcontrol.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱ
serialȱnumber.ȱPlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱremoteȱcontrol.ȱ
Partitionȱ
ȱ
ȱ
ȱ
ȱ
Assignȱtheȱrelevantȱpartitionsȱforȱtheȱselectedȱremoteȱcontrol.ȱ
PINȱCodeȱ
4ȱdigitȱPINȱcodeȱusedȱforȱhigherȱsecurityȱwhenȱsendingȱcommandsȱfromȱtheȱremoteȱ
control.ȱTheȱcodeȱcanȱbeȱcomprisedȱfromȱdigitsȱ1,2,3,4.ȱȱ
Note:ȱTheȱuseȱofȱtheȱPINȱcodeȱdependsȱonȱtheȱcontrolȱQuickȱPOȱorȱsystemȱcontrolȱQuickȱSetȱ
PanicȱEnableȱ
ȱ
ȱ
Defineȱwhetherȱsendingȱpanicȱalarmȱfromȱtheȱremoteȱcontrolȱisȱpermitted.ȱIfȱpermitted,ȱ
pressingȱonȱkeysȱ
alarm.ȱ
ȱandȱ
ȱsimultaneouslyȱforȱ2ȱsecondsȱonȱtheȱwillȱsendȱaȱpanicȱ
POȱButtonȱ1/2/3ȱ
ȱ
ȱ
Eachȱremoteȱcontrolȱcanȱactivateȱupȱtoȱ3ȱoutputs.ȱAssignȱtoȱeachȱofȱtheȱkeysȱ1Ȭ3ȱtheȱ
relevantȱoutput.ȱ
Page 4-29
AgilityȱEngineerȱManualȱ
ȱ
Controlsȱ
TheȱControlsȱmenuȱoptionsȱareȱusedȱforȱbothȱtypesȱofȱremoteȱcontrols.ȱ
Remote Controls: Controls
Control
InstantȱF.ȱSetȱ
NOȱ
ȱ
YES:ȱFullȱsettingȱfromȱanyȱremoteȱcontrolȱwillȱbeȱinstant.ȱ
NO:ȱFullȱsettingȱfromȱanyȱremoteȱcontrolȱwillȱbeȱdelayed,ȱfollowingȱexitȱdelayȱ1.ȱ
InstantȱPartȱSetȱ
NOȱ
ȱ
YES:ȱPartȱSettingȱfromȱanyȱremoteȱcontrolȱwillȱbeȱinstant.ȱ
NO:ȱPartȱSettingȱfromȱanyȱremoteȱcontrolȱwillȱbeȱdelayed,ȱfollowingȱexitȱdelayȱ1.ȱ
Unsetȱ+ȱCodeȱ(Forȱ2ȱWayȱRemoteȱControls)ȱ
NOȱ
ȱ
DefinesȱifȱaȱPINȱcodeȱisȱrequiredȱtoȱperformȱtheȱunsetȱoperationȱwhileȱusingȱanyȱofȱtheȱ
bidirectionalȱremoteȱcontrols.ȱȱ
ParentȱControlȱ
TheȱParentȱControlȱoptionȱisȱusedȱtoȱmonitorȱtheȱactivityȱofȱchildren.ȱThisȱoptionȱallowsȱ
youȱtoȱmonitorȱwhenȱtheȱchildrenȱarriveȱhomeȱandȱunsetȱtheȱsystemȱorȱwhenȱtheyȱsetȱtheȱ
systemȱinȱFullȱSet,ȱusingȱaȱremoteȱcontrolȱorȱtheȱkeypad.ȱWithȱeachȱactivation/deactivationȱ
ofȱtheȱsystemȱaȱmessageȱisȱsentȱtoȱaȱspecifiedȱFollowȱMeȱnumber.ȱ
Afterȱselectingȱthisȱoption,ȱusingȱtheȱ
key,ȱdefineȱwhichȱofȱtheȱremoteȱcontrolsȱareȱ
authorizedȱwithȱthisȱfeatureȱandȱwhichȱareȱnot.ȱȱ
2.2.3 Keypads
Theȱsystemȱcanȱsupportȱupȱtoȱ3ȱwirelessȱkeypads.ȱȱ
Forȱdetailedȱinformationȱregardingȱtheȱoperationȱofȱtheȱkeypadsȱreferȱtoȱtheȱinstructionsȱ
suppliedȱwithȱtheȱproduct.ȱ
Parametersȱ
Keypads: Parameters
Parameter
Default
Range
Labelȱ
ȱ
ȱ
ȱ
ȱ
Aȱlabelȱidentifyingȱtheȱkeypadȱ
SerialȱNumberȱ
TheȱinternalȱIDȱnumberȱofȱtheȱkeypad.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱserialȱ
number.ȱPlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱremoteȱkeypad.ȱ
Page 4-30
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Keypads: Parameters
Parameter
Default
EmergencyȱKeysȱ
YESȱ
Range
YES/NOȱ
Definesȱwhetherȱtheȱfollowingȱkeysȱwillȱoperateȱasȱemergencyȱkeys:ȱ
Œ
Keysȱ
ȱandȱ
ȱwhenȱpressedȱsimultaneouslyȱwillȱsendȱaȱfireȱalarm.ȱ
Œ
Keysȱ
ȱandȱ
ȱwhenȱpressedȱsimultaneouslyȱwillȱsendȱanȱemergencyȱalarm.ȱ
ȱ
FunctionȱKeyȱ
Definesȱtheȱoperationȱofȱtheȱ
Œ
Œ
Œ
Panicȱ
ȱ
ȱ
ȱkeysȱforȱeachȱkeypad.ȱ
Disable:ȱKeysȱdisabled.ȱ
Panic:ȱSendȱaȱpanicȱalarmȱtoȱtheȱalarmȱreceivingȱcenter.ȱ
ARCȱListenȬInȱ&ȱTalk:ȱTheȱsystemȱdialsȱtheȱARCȱtoȱestablishȱ2Ȭwayȱcommunication.ȱ
POȱControlȱȱ
ȱ
Assignȱoutputsȱthatȱwillȱbeȱactivatedȱbyȱaȱlongȱpressȱonȱkeysȱ
bidirectionalȱkeypad.ȱ
ȱ
onȱtheȱ
Notes:ȱȱ
OutputsȱcanȱbeȱassignedȱonlyȱifȱI/Oȱisȱassignedȱtoȱtheȱsystem.ȱ
Eachȱkeypadȱcanȱactivateȱdifferentȱoutputs.ȱȱ
OnlyȱoutputsȱdefinedȱasȱFollowȱCodeȱcanȱbeȱactivatedȱbyȱtheȱkeypadȱkeys
Controlsȱ
TheȱControlsȱmenuȱdefinesȱprogrammingȱoptionsȱthatȱareȱusedȱforȱallȱkeypads.ȱ
Keypads: Controls
Parameter
Default
Range
RFȱWakeȬupȱ
NOȱ
ȱ
Determinesȱwhetherȱtheȱsystemȱcanȱwakeȱtheȱkeypadȱupȱduringȱexit/entryȱtimesȱorȱ
whenȱfailingȱtoȱsetȱtheȱsystem.ȱ
YES:ȱTheȱsystemȱwakesȱtheȱkeypad.ȱ
NO:ȱTheȱsystemȱcannotȱwakeȱupȱaȱkeypad.ȱUseȱthisȱoptionȱtoȱsaveȱbatteryȱlife.ȱ(Default)ȱ
Page 4-31
AgilityȱEngineerȱManualȱ
ȱ
2.2.4 Sounders
TheȱSoundersȱmenuȱenablesȱtoȱdefineȱallȱparametersȱofȱexternalȱandȱinternalȱwirelessȱ
soundersȱthatȱcanȱbeȱconnectedȱtoȱtheȱsystem.ȱUpȱtoȱ3ȱsoundersȱcanȱbeȱaddedȱtoȱtheȱ
system.ȱȱ
Forȱdetailedȱinformationȱregardingȱtheȱoperationȱofȱtheȱsoundersȱreferȱtoȱtheȱinstructionsȱ
suppliedȱwithȱtheȱproduct.ȱȱȱȱȱ
Wireless Device: Sounders
Parameter
Default
Labelȱ
Range
ȱ
ȱ
ȱ
ȱ
Aȱlabelȱidentifyingȱtheȱsounder.ȱ
SerialȱNumberȱ
TheȱinternalȱIDȱnumberȱofȱtheȱsounders.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱserialȱ
number.ȱPlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱsounder.ȱ
Partitionȱ
ȱ
ȱ
Assignȱtheȱpartitionsȱthatȱwillȱeffectȱtheȱsounderȱoperation.ȱ
Supervisionȱ
YESȱ
ȱ
Chooseȱifȱtheȱsounderȱwillȱbeȱsupervisedȱorȱnot.ȱ
Volumeȱ
9ȱ
0Ȭ9ȱ
Defineȱtheȱvolumeȱofȱtheȱsounderȱforȱtheȱfollowingȱscenariosȱinȱtheȱsystem.ȱ
AlarmȱVolumeȱ
9ȱ
0Ȭ9ȱ
Theȱsoundȱvolumeȱproducedȱduringȱalarmȱ(0ȱindicatesȱsilence).ȱ
SquawkȱVolumeȱ
9ȱ
0Ȭ9ȱ
Theȱsoundȱvolumeȱproducedȱduringȱsquawkȱsoundsȱ(0ȱindicatesȱsilence).ȱ
Exit/EntryȱVolumeȱ
9ȱ
0Ȭ9ȱ
Theȱsoundȱvolumeȱproducedȱduringȱexit/entryȱtime.ȱ(0ȱindicatesȱsilence).ȱ
Strobeȱ(Externalȱsounderȱonly)ȱ
9ȱ
0Ȭ9ȱ
ȱ
ȱ
Definesȱtheȱparametersȱforȱtheȱstrobeȱofȱtheȱexternalȱsounder.ȱ
StrobeȱControlȱȱ
DefinesȱtheȱStrobeȱoperationȱmode:ȱ
Œ Alwaysȱoff:ȱTheȱstrobeȱisȱdeactivatedȱ
Œ FollowȱBell:ȱTheȱstrobeȱisȱactivatedȱwhenȱtheȱsounderȱbellȱisȱtriggeredȱ
Œ FollowȱAlarm:ȱTheȱstrobeȱisȱactivatedȱwhenȱanȱalarmȱeventȱoccursȱinȱtheȱȱ
ȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱsystem.ȱ
Page 4-32
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Wireless Device: Sounders
Parameter
StrobeȱBlinkȱ
Default
Range
40ȱ
ȱ
Definesȱtheȱnumberȱofȱtimesȱthatȱtheȱstrobeȱwillȱblinkȱinȱaȱminute:ȱ
20ȱtimesȱperȱminuteȱ
30ȱtimesȱperȱminuteȱ
40ȱtimesȱperȱminuteȱȱ
50ȱtimesȱperȱminuteȱ
60ȱtimesȱperȱminuteȱ
Œ
Œ
Œ
Œ
Œ
StrobeȱSetȱBlinkȱ
05ȱ
00Ȭ20ȱ
Definesȱtheȱtimeȱthatȱtheȱstrobeȱwillȱblinkȱwhenȱtheȱsystemȱisȱset.ȱ
2.2.5 I/O Wireless Expander
TheȱWirelessȱInput/OutputȱExpanderȱisȱaȱselfȱpoweredȱdeviceȱenablingȱsystemȱcontrolȱofȱ
additionalȱ4ȱwiredȱzonesȱandȱhasȱhomeȱautomationȱcapabilities.ȱWithȱtheȱI/OȱExpanderȱtheȱ
systemȱcanȱcontrolȱ4ȱoutputsȱandȱ16ȱhomeȱautomationȱunitsȱemployingȱtheȱX10ȱprotocol.ȱ
WiredȱZonesȱ
Theȱ4ȱinputsȱonȱtheȱI/OȱExpanderȱareȱregardedȱasȱzonesȱ33Ȭ36ȱinȱtheȱsystem.ȱȱ
I/O Expander: Wired Zones
Parameter
Default
Labelȱ
Range
ȱ
ȱ
1ȱ
ȱ
Aȱlabelȱidentifiesȱtheȱzoneȱinȱtheȱsystem.ȱ(upȱtoȱ16ȱcharacters).ȱ
Partitionȱ
Theȱpartitionsȱassignmentȱforȱeachȱzone.ȱ
Typeȱ
Intruderȱ ȱ
Containsȱparametersȱthatȱenableȱyouȱtoȱprogramȱtheȱzoneȱtypeȱforȱanyȱzone.ȱReferȱtoȱtheȱ
listȱofȱoptionsȱforȱtheȱZoneȱTypeȱonȱpageȱ4Ȭ19.ȱ
Soundȱ
Bellȱ
ȱ
Containsȱparametersȱthatȱenableȱyouȱtoȱprogramȱtheȱsoundȱproducedȱwhenȱaȱsystemȱ
zoneȱtriggersȱanȱalarmȱforȱtheȱtimeȱdefinedȱunderȱtheȱBellȱTimeȱOutȱparameter.ȱReferȱtoȱ
theȱlistȱofȱoptionsȱforȱtheȱZoneȱSoundȱonȱpageȱ4Ȭ23.ȱ
Advancedȱprogrammingȱ
ȱ
Chimeȱ
ȱ
Noneȱ
ȱ
TheȱChimeȱparameterȱisȱusedȱasȱanȱaudibleȱindicationȱtoȱaȱzoneȱviolationȱwhileȱtheȱ
systemȱisȱUnset.ȱWhenȱviolated,ȱtheȱmainȱunitȱcanȱsoundȱoneȱofȱtheȱ5ȱavailableȱchimeȱ
options.ȱȱ
Page 4-33
AgilityȱEngineerȱManualȱ
ȱ
I/O Expander: Wired Zones
Parameter
Default
Range
Controlsȱ
ForcedȱSetȱ
NOȱ
ȱ
Defineȱwhetherȱtheȱzoneȱcanȱbeȱforcedȱsetȱorȱnot.ȱForȱmoreȱinformationȱ
regardingȱtheȱforceȱsettingȱfeature,ȱreferȱtoȱpageȱ4Ȭ25.ȱ
NoȱActivityȱ
NOȱ
ȱ
DeterminesȱwhetherȱtheȱzoneȱparticipatesȱinȱtheȱNoȱActivityȱfunction.ȱTheȱNoȱ
Activityȱfunctionȱisȱforȱreceptionȱofȱsignalsȱusedȱtoȱmonitorȱtheȱactivityȱofȱsick,ȱ
elderlyȱorȱdisabledȱpeople.ȱ.Forȱmoreȱinformationȱregardingȱtheȱforceȱsettingȱ
feature,ȱreferȱtoȱpageȱ4Ȭ25.ȱ
AbortȱAlarmȱ
YESȱ
ȱ
ThisȱparameterȱdefinesȱwhetherȱaȱzoneȱalarmȱreportȱtoȱtheȱARCȱwillȱbeȱ
immediateȱorȱdelayed.ȱForȱmoreȱinformationȱregardingȱtheȱforceȱarmingȱfeatureȱ
referȱtoȱpageȱ4Ȭ25.ȱ
Terminationȱ
ȱ
ȱ
TheȱTerminationȱmenuȱenablesȱyouȱtoȱprogramȱtheȱconnectionȱtypeȱusedȱforȱtheȱwiredȱ
zonesȱ33Ȭ36.ȱTheȱactualȱ(physical)ȱterminationȱforȱeachȱzoneȱmustȱcomplyȱwithȱthatȱ
selectedȱinȱtheȱzoneȱterminationȱmenu.ȱ
Œ
N/C:ȱ(NormallyȱClosed)ȱUsesȱnormallyȬclosedȱcontactsȱandȱnoȱterminatingȱEndȬofȬ
LineȱResistor.ȱ
Œ
N/O:ȱ(NormallyȱOpen)ȱUsesȱnormallyȬopenȱcontactsȱandȱnoȱterminatingȱEndȬofȬLineȱ
Resistorȱȱ
Œ
EOL:ȱ(EndȱofȱLine)ȱUsesȱnormallyȬclosedȱ(NC)ȱand/orȱnormallyȬopenȱ(NO)ȱcontactsȱ
inȱaȱzoneȱterminatedȱbyȱaȱsuppliedȱ2200:ȱEndȬofȬLineȱResistorȱȱ
NORMALLY CLOSED
ZONE CONFIGURATION
zone
com
NORMALLY OPEN ZONE
CONFIGURATION
zone
com
END OF LINE ZONE
(N.C CONTACT)
zone
com
END OF LINE ZONE
(N.O CONTACT)
zone
2.2 K
2.2 K
ALARM
ALARM
DETECTOR
DETECTOR
ALARM
ALARM
DETECTOR
Page 4-34
com
DETECTOR
ȱ
D
AgilityȱEngineerȱManualȱ
ȱ
ȱ
I/O Expander: Wired Zones
Parameter
Default
Range
Loopȱresponseȱ
ȱ
ȱ
TheȱLoopȱResponseȱmenuȱenablesȱyouȱtoȱsetȱtheȱdifferentȱtimesȱforȱwhichȱaȱwiredȱzoneȱ
violationȱmustȱexistȱbeforeȱtheȱzoneȱwillȱtriggerȱanȱalarmȱcondition.ȱ
Theȱfollowingȱoptionȱareȱavailable:ȱ
Normalȱ400ȱmsȱȱ
0.5ȱhoursȱȱ
2ȱhoursȱȱ
3.5ȱhoursȱȱ
Slowȱ1ȱsecondȱ
1ȱhourȱ
2.5ȱhoursȱ
4ȱhoursȱ
Fastȱ10ȱmsȱ
1.5ȱhoursȱ
3ȱhoursȱ
ȱ
ȱ
DetectionȱModeȱ
Œ
Œ
ȱ
ȱ
Normalȱ(Default):ȱ2.5ȱminutesȱdeadȱtimeȱbetweenȱalarmȱdetectionsȱtransmissions.ȱ
Fastȱ(WalkȱTest):ȱAlarmȱdetectionȱisȱimmediatelyȱtransmitted.ȱ
OutputȱParametersȱ
TheȱI/Oȱexpanderȱhasȱ4ȱphysicalȱoutputsȱonȱboard.ȱ(2ȱrelayȱ3Ampȱandȱ2ȱTransistorȱOutputsȱ
(500ȱmA)
I/O Expander: Output Parameters
Parameter
Labelȱ
ȱ
ȱ
ȱ
ȱ
Aȱlabelȱidentifiesȱtheȱoutputȱinȱtheȱsystem.ȱȱ
Typeȱ
Thereȱareȱ4ȱtypesȱofȱoutputsȱinȱtheȱsystemȱasȱfollowsȱ
Œ
Notȱusedȱ
Œ
FollowȱSystem:ȱTheȱprogrammingȱoutputȱwillȱfollowȱaȱSystemȱEventȱ
Œ
FollowȱPartition:ȱTheȱprogrammingȱoutputȱwillȱfollowȱaȱPartitionȱEvent.ȱȱ
Œ
FollowȱZone:ȱTheȱprogrammingȱoutputȱwillȱfollowȱaȱZoneȱEvent.ȱEachȱProgrammingȱ
Outputȱcanȱbeȱactivatedȱbyȱaȱgroupȱofȱupȱtoȱfiveȱzones.ȱ
Œ
FollowȱCode:ȱTheȱprogrammingȱoutputȱwillȱbeȱactivatedȱbyȱaȱuserȱdefinedȱasȱPOȱ
Controlȱorȱfromȱtheȱuserȱprogrammingȱmenu.ȱ
FollowȱSystemȱEvents:ȱ
ȱ
ȱ
Bellȱ
ȱ
ȱ
Activatesȱwhenȱaȱbellȱisȱtriggered.ȱIfȱaȱbellȱdelayȱwasȱdefined,ȱtheȱprogrammingȱ
outputȱwillȱbeȱactivatedȱafterȱtheȱdelayȱperiod.ȱ
NoȱTelephoneȱLineȱ
ȱ
ȱ
Activatesȱwhenȱaȱtelephoneȱlineȱfaultȱisȱdetected.ȱIfȱaȱPSTNȱLostȱDelayȱtimeȱ
periodȱisȱdefined,ȱtheȱprogrammingȱoutputȱwillȱbeȱactivatedȱafterȱtheȱdelayȱ
timeȱ
Page 4-35
AgilityȱEngineerȱManualȱ
ȱ
I/O Expander: Output Parameters
Parameter
ARCȱCommunicationȱFailȱ
ȱ
ȱ
ActivatesȱwhenȱcommunicationȱwithȱtheȱCentralȱStationȱcannotȱbeȱestablished.ȱ
DeactivatesȱafterȱaȱsuccessfulȱcallȱisȱestablishedȱwithȱtheȱCentralȱStation.ȱ
GeneralȱFaultȱ
ȱ
ȱ
ȱ
ȱ
Activatesȱwhenȱaȱsystemȱfaultȱconditionȱisȱdetected.ȱȱ
Deactivatesȱafterȱtheȱfaultȱhasȱbeenȱcorrectedȱ
MainȱUnitȱȱLowȱbatteryȱ
ActivatesȱwhenȱtheȱAgilityȱbatteryȱhasȱinsufficientȱreserveȱcapacityȱandȱtheȱ
voltageȱdecreasesȱtoȱ6V.ȱ
ACȱLossȱ
ȱ
ȱ
ActivatesȱwhenȱtheȱsourceȱofȱtheȱMainȱPanelȇsȱACȱpowerȱisȱinterrupted.ȱThisȱ
activationȱwillȱfollowȱtheȱdelayȱtimeȱdefinedȱinȱtheȱsystemȱcontrolȱtimesȱandȱtheȱ
ACȱOffȱDelayȱTimeȱparameter.ȱ
Bellȱburglaryȱ
ȱ
ȱ
ActivatesȱtheȱProgrammingȱOutputȱafterȱanyȱbellȱburglaryȱalarmȱinȱanyȱ
partitionȱinȱtheȱsystem.ȱ
Schedulerȱ
ȱ
ȱ
Theȱprogrammingȱoutputȱwillȱfollowȱtheȱpredefinedȱtimeȱprogrammingȱthatȱisȱ
definedȱinȱtheȱschedulerȱofȱtheȱweeklyȱprogramsȱforȱprogrammingȱoutputȱ
activation.ȱ
Tamperȱ
ȱ
ȱ
ActivatesȱtheȱprogrammingȱoutputȱwhenȱaȱTamperȱoccursȱinȱtheȱsystem.ȱ
Duressȱ
ActivatesȱtheȱProgrammingȱOutputȱwhenȱaȱduressȱalarmȱisȱinitiatedȱbyȱanyȱ
userȱdefinedȱasȱduressȱcode.ȱ
GSMȱFaultȱ
ActivatesȱtheȱprogrammingȱoutputȱwhenȱthereȱisȱfaultȱinȱtheȱGSMȱmodule.ȱ
FollowȱPartitionȱEvents:ȱ
ȱ
Readyȱ
ȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱallȱtheȱselectedȱpartition(s)ȱareȱinȱtheȱ
Readyȱstate.ȱ
Page 4-36
AgilityȱEngineerȱManualȱ
ȱ
ȱ
I/O Expander: Output Parameters
Parameter
Setȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱpartition(s)ȱisȱsetȱinȱFullȱ
Setȱmode.ȱTheȱprogrammingȱoutputȱwillȱbeȱactivatedȱimmediately,ȱregardlessȱ
ofȱtheȱExitȱDelayȱtimeȱperiod.ȱ
Unsetȱ
ActivatesȱtheȱProgrammingȱOutputȱwhenȱtheȱselectedȱpartition(s)ȱisȱunset.ȱ
Alarmȱ
ȱ
ȱ
ActivatesȱtheȱProgrammingȱOutputȱwhenȱanȱalarmȱoccursȱinȱtheȱselectedȱ
partition(s).ȱ
Intruderȱalarmȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱanȱintrusionȱ(Burglary)ȱalarmȱoccursȱ
inȱtheȱselectedȱpartition(s).ȱ
Fireȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱaȱfireȱalarmȱisȱtriggeredȱinȱtheȱselectedȱ
partition(s)ȱfromȱtheȱkeypadsȱorȱaȱzoneȱdefinedȱasȱFire.ȱ
Panicȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱaȱpanicȱalarmȱisȱtriggeredȱinȱtheȱ
selectedȱpartition(s)ȱfromȱtheȱkeypads,ȱremoteȱcontrolsȱorȱaȱzoneȱdefinedȱasȱ
Panic.ȱ
Specialȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱaȱspecialȱalarmȱisȱtriggeredȱinȱtheȱ
selectedȱpartition(s)ȱfromȱtheȱkeypadsȱorȱaȱzoneȱdefinedȱasȱSpecialȱ.ȱ
Exit/Entryȱ
ȱ
ȱ
ActivatesȱtheȱProgrammingȱOutputȱwhenȱtheȱselectedȱpartition(s)ȱinitiatesȱanȱ
Exit/EntryȱDelayȱperiod.ȱ
ZoneȱOmitȱ
ȱ
ȱ
ActivatesȱtheȱProgrammingȱOutputȱwhenȱtheȱrelevantȱpartitionsȱareȱinȱSETȱorȱ
PARTȱSETȱmodeȱandȱanyȱzoneȱinȱtheȱrelevantȱpartitionsȱisȱomitted.ȱ
AutoȱSetȱAlarmȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱthereȱisȱaȱnotȱreadyȱzoneȱatȱtheȱendȱofȱ
theȱpreȬȱwarningȱtimeȱduringȱanȱautoȬsetȱprocess.ȱTheȱoutputȱrestoreȱshallȱbeȱonȱ
BellȬTimeoutȱorȱatȱuserȱUnset.ȱ
ZoneȱLostȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱthereȱisȱaȱlostȱwirelessȱzoneȱinȱtheȱ
system.ȱTheȱoutputȱrestoreȱshallȱbeȱonȱBellȬTimeoutȱorȱatȱuserȱUnset.ȱ
Page 4-37
AgilityȱEngineerȱManualȱ
ȱ
I/O Expander: Output Parameters
Parameter
PartȱSetȱFollowȱ
ȱ
ȱ
ActivatesȱtheȱProgrammingȱOutputȱwhenȱtheȱselectedȱpartition(s)ȱisȱsetȱinȱPartȱ
Setȱmode.ȱ
ChimeȱFollowȱ
ȱ
ȱ
ActivatesȱtheȱProgrammingȱOutputȱfollowingȱaȱchimeȱsoundȱinȱtheȱselectedȱ
partition(s)ȱ
BellȱP.ȱSetȱOffȱ
ȱ
ȱ
Thisȱparameterȱcausesȱtheȱprogrammingȱoutputȱtoȱfunctionȱasȱfollows:ȱ
Œ
InȱFullȱSettingȱmode,ȱtheȱprogrammingȱoutputȱwillȱfollowȱtheȱbellȱ
activationȱinȱtheȱdefinedȱpartitions.ȱ
Œ
InȱPartȱSettingȱmode,ȱtheȱprogrammingȱoutputȱwillȱnotȱbeȱactivated.ȱ
Bellȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱoneȱofȱtheȱdefinedȱpartitionsȱisȱinȱ
Alarmȱmodeȱandȱtheȱbellȱisȱtriggered.ȱThisȱenablesȱtheȱconnectionȱofȱdifferentȱ
soundersȱtoȱdifferentȱpartitions.ȱ
FollowȱZoneȱEvents:ȱ
Zoneȱ
ȱ
ȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱzoneȱisȱtripped.ȱȱ
TheȱtrippedȱzoneȱneedȱnotȱbeȱsetȱtoȱtriggerȱtheȱProgrammingȱOutput.ȱ
Alarmȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱzoneȱcausesȱanȱalarm.ȱ
Setȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱzonesȱareȱset.ȱ
Unsetȱ
ȱ
ȱ
Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱzonesȱareȱunset.ȱ
FollowȱUserȱCode:ȱ
ȱ
ȱ
DefinesȱtheȱUserȱCode(s)ȱforȱtriggeringȱtheȱselectedȱPO.ȱTheȱactivationȱofȱtheȱ
ȱȱkeyȱtoȱtoggleȱ
POȱisȱperformedȱfromȱtheȱUserȱActivitiesȱmenu.ȱUseȱtheȱ
betweenȱ[Y]ȱYESȱorȱ[N]ȱNOȱforȱeachȱuserȱchosenȱtoȱtripȱtheȱdesignatedȱ
ProgrammingȱOutput.ȱ
Patternȱ
ȱ
ȱ
Forȱeachȱoutputȱyouȱneedȱtoȱdefineȱtheȱpatternȱofȱoperation.ȱTheȱavailableȱoptionsȱȱare:ȱ
Page 4-38
AgilityȱEngineerȱManualȱ
ȱ
ȱ
I/O Expander: Output Parameters
Parameter
PulseȱN/Oȱȱ(NormallyȱOpen)ȱ
ȱ
ȱ
TheȱprogrammingȱoutputȱisȱalwaysȱDeactivatedȱ(N/O)ȱbeforeȱitȱisȱtriggeredȱ
(pulledȱup).ȱ
Whenȱtriggered,ȱitȱactivatesȱ(pulledȱdown)ȱforȱtheȱPulseȱDurationȱspecified,ȱ
thenȱdeactivatesȱautomatically.ȱ
LatchedȱN/Oȱȱ(NormallyȱOpen)ȱ
ȱ
ȱ
TheȱProgrammingȱOutputȱisȱalwaysȱDeactivatedȱ(N/O)ȱbeforeȱitȱisȱtriggeredȱ
(pulledȱup).ȱWhenȱtriggered,ȱitȱactivatesȱ(pulledȱdown)ȱandȱremainsȱactivatedȱ
(latched)ȱuntilȱtheȱoperationȱisȱrestored.ȱ
PulseȱN/Cȱȱ(NormallyȱClosed)ȱ
ȱ
ȱ
TheȱprogrammingȱoutputȱisȱalwaysȱActivatedȱ(N/C)ȱbeforeȱitȱisȱtriggeredȱ
(pulledȱdownȱtoȱnegative).ȱWhenȱtriggered,ȱitȱdeactivatesȱforȱtheȱPulseȱDurationȱ
specifiedȱbelowȱandȱthenȱreactivatesȱautomatically.ȱ
LatchedȱN/Cȱȱ(NormallyȱClose)ȱ
ȱ
ȱ
TheȱProgrammingȱOutputȱisȱalwaysȱActivatedȱ(N/C)ȱbeforeȱitȱisȱtriggeredȱ
(pulledȱdownȱtoȱnegative).ȱWhenȱtriggered,ȱitȱdeactivatesȱandȱremainsȱ
deactivatedȱ(latched)ȱuntilȱtheȱoperationȱisȱrestored.ȱ
Activationȱȱ/ȱDeactivationȱ
ȱ
ȱ
Whenȱtheȱprogrammingȱoutputȱisȱfollowingȱmoreȱthanȱoneȱpartitionȱorȱzone,ȱtheȱ
engineerȱcanȱchooseȱtheȱlogicȱofȱtheȱProgrammingȱOutputȱactivationȱasȱfollows:ȱ
Œ
IfȱtheȱpatternȱoperationȱofȱtheȱoutputȱisȱdefinedȱasȱLatchȱN/OȱorȱLatchȱN/C,ȱtheȱ
activationȱandȱdeactivationȱofȱtheȱoutputsȱcanȱȱfollowȱeitherȱafterȱallȱtheȱ
Partitions/ZonesȱorȱafterȱanyȱofȱtheȱPartitions/Zones.ȱ
Œ
IfȱtheȱPatternȱoperationȱofȱtheȱoutputȱisȱdefinedȱasȱPulseȱN/OȱorȱPulseȱN/C,ȱtheȱ
activationȱofȱtheȱoutputsȱcanȱȱfollowȱeitherȱafterȱallȱtheȱPartitions/Zonesȱorȱafterȱanyȱ
ofȱtheȱPartitions/Zones.ȱTheȱdeactivationȱoperationȱfollowsȱtheȱdefinedȱtimeȱperiod.ȱ
PulseȱDurationȱLengthȱ
05ȱsecȱ
01Ȭ90ȱ
TheȱtimeȱthatȱanȱoutputȱdefinedȱasȱPulsedȱN.OȱorȱPulsedȱN.Cȱwillȱbeȱactivated.ȱAtȱtheȱ
endȱofȱtheȱpulseȱdurationȱtheȱoutputȱreactivatesȱautomatically.ȱ
Page 4-39
AgilityȱEngineerȱManualȱ
ȱ
XȬ10ȱOutputsȱ
TheȱwirelessȱI/OȱexpanderȱenablesȱtheȱsystemȱtoȱcontrolȱXȱ–ȱ10ȱdevices.ȱTheȱI/Oȱexpanderȱ
convertsȱtheȱinformationȱsentȱfromȱtheȱprogrammableȱprogrammingȱoutputȱintoȱtheȱXȱ–ȱ10ȱ
protocol.ȱUpȱtoȱsixteenȱXȬ10ȱdevicesȱcanȱbeȱactivated.ȱTheseȱareȱrecognizedȱinȱtheȱsystemȱasȱ
outputsȱ5Ȭ20.ȱ
I/O Expander: X-10 Outputs
Parameter
Default
Labelȱ
Range
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
05ȱsecȱ
01Ȭ90ȱ
Aȱlabelȱidentifiesȱtheȱoutputȱinȱtheȱsystemȱ
Typeȱ
Referȱtoȱtheȱexplanationȱunderȱtheȱprogrammingȱoutputȱsection.ȱ
Patternȱ
Referȱtoȱtheȱexplanationȱunderȱtheȱprogrammingȱoutputȱsection.ȱ
PulseȱLengthȱȱȱ
Referȱtoȱtheȱexplanationȱunderȱtheȱprogrammingȱoutputȱsection.ȱ
Parametersȱ
TheȱfollowingȱtableȱdescribesȱtheȱgeneralȱparametersȱforȱtheȱI/Oȱmodule.ȱ
I/O Expander: Parameters
Parameter
Default
SerialȱNumberȱ
ȱ
Range
ȱ
TheȱinternalȱIDȱnumberȱofȱtheȱI/OȱExpander.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱ
serialȱnumber.ȱ
Controlsȱ
I/OȱExpanderȱSupervisionȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ChooseȱifȱtheȱI/OȱExpanderȱwillȱbeȱsupervisedȱorȱnot.ȱ
QuickȱOutputȱOperationȱ
AȱuserȱcanȱactivateȱaȱPOȱfromȱtheȱbidirectionalȱremoteȱcontrolȱorȱkeysȱ
ȱonȱtheȱwirelessȱkeypadȱwithoutȱtheȱneedȱtoȱenterȱhisȱuserȱcode.ȱ
XȬ10ȱHouseȱIDȱ
ȱ
ȱ
Definesȱtheȱhouseȱcode,ȱwhichȱmatchesȱtheȱcodeȱdefinedȱbyȱtheȱXȬ10ȱmodules.ȱȱ
POȱDTMFȱControlȱ
ȱ
ȱ
TheȱAgilityȱenablesȱtoȱactivateȱ8ȱprogrammingȱoutputsȱfromȱremoteȱDTMFȱphone.ȱToȱ
operateȱaȱPOȱviaȱtheȱtelephoneȱyouȱmustȱassignȱaȱspecificȱPOȱtoȱaȱdigitȱonȱtheȱphone.ȱȱ
Page 4-40
AgilityȱEngineerȱManualȱ
ȱ
ȱ
2.3 Identification
Thisȱoptionȱprovidesȱtheȱabilityȱtoȱidentifyȱtheȱserialȱnumberȱofȱaȱwirelessȱdeviceȱinȱtheȱ
systemȱfromȱaȱkeypadȱorȱfromȱtheȱconfigurationȱsoftware.ȱȱ
Whenȱusingȱaȱkeypadȱfollowȱthisȱprocedure:ȱ
GoȱtoȱProgrammingȱÆȱRadioȱDevicesȱMenuȱÆȱIdentificationȱandȱpressȱ
followingȱmessageȱappearsȱonȱtheȱkeypadȱLCD:ȱ
.ȱTheȱ
ȱ
Pressȱonȱtheȱdevice’sȱLearnȱmode.ȱTheȱserialȱnumberȱofȱtheȱrelevantȱdeviceȱappearsȱonȱ
theȱkeypadȱLCD.ȱ
Page 4-41
AgilityȱEngineerȱManualȱ
ȱ
3. Programming: Codes Menu
TheȱCodesȱmenuȱprovidesȱtheȱabilityȱdoȱdefineȱparametersȱandȱcodesȱforȱtheȱsystemȱusers.ȱȱ
3.1 User
Userȱrightsȱcanȱbeȱdefinedȱbyȱallocatingȱeachȱuserȱaȱspecificȱauthorityȱlevelȱandȱspecificȱ
partitions.ȱUpȱtoȱ32ȱusersȱcanȱbeȱdefinedȱinȱtheȱsystem.ȱ
Codes: User Codes
Parameter
Default
Labelsȱ
ȱ
Usedȱtoȱdefineȱtheȱuserȱname.ȱUpȱtȱoȱ32ȱcharactersȱcanȱbeȱused.ȱ
Partitionȱ
ȱ
Enablesȱyouȱtoȱassignȱtheȱpartition(s)ȱinȱwhichȱallȱUserȱCodesȱ(exceptȱforȱtheȱGrandȱ
Master)ȱwillȱoperate.ȱ
AuthorityȱLevelȱȱ
ȱ
Allocateȱanȱauthorityȱlevelȱtoȱaȱuserȱaccordingȱtoȱtheȱfollowingȱlist:ȱȱ
User:ȱThereȱareȱnoȱrestrictionsȱinȱtheȱnumberȱofȱUserȱCodesȱ(asȱlongȱasȱtheyȱdoȱ
notȱexceedȱtheȱnumberȱofȱcodesȱremainingȱinȱtheȱsystem).ȱTheȱUserȱhasȱaccessȱtoȱ
theȱfollowing:ȱȱ
Œ Settingȱandȱunsettingȱ
Œ Omittingȱzonesȱ
Œ Viewingȱsystemȱstatus,ȱfault,ȱandȱalarmȱmemoryȱ
Œ ActivatingȱdesignatedȱProgrammingȱOutputsȱ
Œ Changingȱhis/herȱownȱUserȱCodeȱ
Œ Settingȱkeypadȇsȱsettingsȱ
Cleaner:ȱTheȱCleanerȱCodeȱisȱaȱtemporaryȱcode,ȱwhichȱisȱtoȱbeȱimmediatelyȱ
deletedȱfromȱtheȱsystemȱasȱsoonȱasȱitȱisȱusedȱtoȱset.ȱThisȱcodeȱisȱtypicallyȱusedȱforȱ
maids,ȱhomeȱattendants,ȱandȱrepairmenȱwhoȱmustȱenterȱtheȱpremisesȱbeforeȱtheȱ
owner(s)ȱarrive.ȱTheseȱcodesȱareȱusedȱasȱfollows:ȱ
Œ ForȱoneȬtimeȱsettingȱinȱoneȱorȱmoreȱpartitionsȱ
Œ Ifȱfirstȱusedȱtoȱunsetȱtheȱsystem,ȱtheȱcodeȱmayȱbeȱusedȱonceȱforȱsubsequentȱ
settingȱ
SetȱOnly:ȱThereȱareȱnoȱrestrictionsȱinȱtheȱnumberȱofȱSetȱOnlyȱCodesȱ(asȱlongȱasȱ
theyȱdonȇtȱexceedȱtheȱnumberȱofȱcodesȱremainingȱinȱtheȱsystem).ȱSetȱOnlyȱCodesȱ
areȱusefulȱforȱworkersȱwhoȱarriveȱwhenȱtheȱpremisesȱareȱalreadyȱopen,ȱbutȱ
becauseȱtheyȱareȱlastȱtoȱleave,ȱtheyȇreȱgivenȱtheȱresponsibilityȱtoȱcloseȱtheȱ
premisesȱandȱsetȱtheȱsystem.ȱTheȱusersȱwithȱSetȱOnlyȱCodesȱhaveȱaccessȱforȱ
settingȱoneȱorȱmoreȱpartitions.ȱ
ȱ
Page 4-42
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Codes: User Codes
Parameter
Default
Duress:ȱWhenȱcoercedȱintoȱunsettingȱtheȱsystem,ȱtheȱuserȱcanȱcomplyȱwithȱtheȱ
intruderȇsȱwishesȱwhileȱsendingȱaȱsilentȱduressȱalarmȱtoȱtheȱCentralȱStation.ȱToȱ
doȱso,ȱaȱspecialȱduressȱcodeȱmustȱbeȱused,ȱwhichȱwhenȱused,ȱwillȱunsetȱtheȱ
systemȱinȱtheȱregularȱmanner,ȱwhileȱsimultaneouslyȱtransmittingȱtheȱduressȱ
alarm.ȱInȱanyȱotherȱsituationȱtheȱDuressȱauthorityȱlevelȱbehavesȱasȱtheȱsameȱasȱ
theȱUserȱauthorityȱlevel.ȱ
3.2 Grand Master
TheȱGrandȱMasterȱCodeȱisȱusedȱbyȱtheȱsystemȇsȱownerȱandȱisȱtheȱhighestȱAuthorityȱLevel.ȱȱ
Theȱownerȱcanȱset/changeȱtheȱGrandȱMasterȱCode.ȱȱ
Default:ȱ1234ȱ
Note:ȱInȱtheȱConfigurationȱsoftwareȱtheȱGrandȱMasterȱisȱidentifiedȱasȱCodeȱ00.ȱ
3.3 Engineer
TheȱEngineerȱCodeȱprovidesȱaccessȱtoȱtheȱEngineerȱProgrammingȱmenu,ȱallowingȱ
modificationȱofȱallȱsystemȱparameters.ȱTheȱEngineerȱCodeȱisȱusedȱbyȱtheȱAgilityȱ
installationȱcompanyȱtechnicianȱtoȱprogramȱtheȱsystem.ȱ
TheȱEngineerȱcanȱchangeȱtheȱEngineerȱCode.ȱȱ
Default:ȱ0132ȱ
3.4 Sub-Engineer
TheȱSubȬEngineerȱCodeȱallowsȱlimitedȱaccessȱtoȱselectedȱparametersȱfromȱtheȱEngineerȱ
Programmingȱmenu.ȱItȱisȱusedȱbyȱaȱtechnicianȱsentȱbyȱtheȱAgilityȱinstallationȱcompanyȱtoȱ
carryȱoutȱrestrictedȱtasksȱdefinedȱatȱtheȱtimeȱofȱsystemȱinstallationȱbyȱtheȱinstallationȱ
technician.ȱTheȱSubȬEngineerȱcanȱaccessȱwithȱhisȱcodeȱonlyȱthoseȱprogrammingȱmenusȱ
predefinedȱforȱhisȱaccess.ȱDefault:ȱ0232ȱ
TheȱSubȬEngineerȱisȱprohibitedȱtoȱaccessȱtheȱfollowingȱparameters:ȱ
x
DefaultȱEnableȱ
x
ARCȱEnableȱ
x
ConfigurationȱSoftwareȱEnableȱ
x
CodeȱLengthȱ
x
EngineerȱCodeȱ
Note:ȱInȱtheȱAgilityȱConfigurationȱSoftware,ȱtheȱConfigurationȱSoftwareȱandȱARCȱmenusȱareȱunavailableȱtoȱ
theȱsubȬengineer.ȱ
ȱ
Page 4-43
AgilityȱEngineerȱManualȱ
ȱ
3.5 Code Length
TheȱCodeȱLengthȱspecifiesȱtheȱminimumȱnumberȱofȱdigitsȱrequested.ȱDefault:ȱ4ȱdigitsȱ
Notes:ȱȱ
WhenȱyouȱchangeȱtheȱCodeȱLengthȱparameter,ȱallȱUserȱCodesȱareȱdeletedȱandȱmustȱbeȱreȬprogrammedȱorȱ
downloaded.ȱ
Forȱaȱ6ȬdigitȱCodeȱLengthȱsystem,ȱ4Ȭdigitȱdefaultȱcodesȱlikeȱ1Ȭ2Ȭ3Ȭ4ȱ(GrandȱMaster),ȱ0Ȭ1Ȭ3Ȭ2ȱ(Engineer),ȱandȱ0Ȭ
2Ȭ3Ȭ2ȱ(SubȬEngineer)ȱbecomeȱ1Ȭ2Ȭ3Ȭ4Ȭ0Ȭ0,ȱ0Ȭ1Ȭ3Ȭ2Ȭ0Ȭ0,ȱandȱ0Ȭ2Ȭ3Ȭ2Ȭ0Ȭ0,ȱrespectively.ȱ
IfȱyouȱchangeȱtheȱCodeȱLengthȱbackȱtoȱ4ȱdigits,ȱtheȱsystemȱcodesȱareȱrestoredȱtoȱtheȱdefaultȱ4Ȭdigitȱcodes.ȱ
ȱ
EN50131Ȭ3ȱstandardȱspecifications:ȱ
ŒȱȱAllȱcodeȱlengthȱareȱ4ȱdigits:ȱxxxxȱ
ŒȱȱForȱeachȱdigitȱ0Ȭ9ȱcanȱbeȱusedȱ
ŒȱȱAllȱcodesȱfromȱ0000ȱtoȱ9999ȱareȱacceptableȱ
ŒȱȱInvalidȱcodesȱcannotȱbeȱcreatedȱsinceȱafterȱ4ȱdigitsȱareȱtyped,ȱtheȱȈEnterȈȱisȱautomatic.ȱȱ
ȱȱȱCodesȱareȱrejectedȱwhenȱtryingȱtoȱcreateȱaȱcodeȱthatȱdoesȱnotȱexist.ȱ
3.6 DTMF Code
Thisȱisȱaȱtelephoneȱremoteȱaccessȱcodeȱmadeȱupȱofȱtwoȱdigitsȱthatȱenablesȱentryȱintoȱtheȱ
systemȱwhenȱdialingȱinȱfromȱaȱremoteȱnumber.ȱȱ
Defaultȱcode=00ȱ
3.7 Parent Control
TheȱParentȱControlȱoptionȱisȱusedȱtoȱmonitorȱtheȱactivityȱofȱchildren.ȱThisȱoptionȱallowsȱallȱ
usersȱtoȱmonitorȱwhenȱtheȱchildrenȱarriveȱhomeȱandȱunsetȱtheȱsystemȱorȱwhenȱtheyȱsetȱtheȱ
systemȱinȱFullȱSetȱmode.ȱWithȱeachȱactivation/deactivationȱofȱtheȱsystemȱaȱmessageȱisȱsentȱ
toȱaȱspecifiedȱFollowȱMeȱnumber.ȱ
ȱȱkeyȱtoȱtoggleȱbetweenȱ[Y]ȱYESȱorȱ[N]ȱNOȱforȱeachȱuserȱchosenȱtoȱbeȱassignedȱ
Useȱtheȱ
withȱtheȱparentȱcontrolȱfeature.ȱȱ
Page 4-44
AgilityȱEngineerȱManualȱ
ȱ
ȱ
4. Programming: Communication Menu
TheȱCommunicationȱmenuȱprovidesȱaccessȱtoȱsubmenusȱandȱtheirȱrelatedȱparametersȱthatȱ
enableȱtheȱsystemȱtoȱestablishȱcommunicationȱwithȱtheȱARC,ȱFollowȱMeȱorȱ
Upload/Download.ȱ
TheȱCommunicationȱmenuȱisȱdividedȱintoȱtheȱfollowingȱsubȬmenus:ȱ
1.ȱMethodȱ
2.ȱARCȱ
2.ȱConfigurationȱSoftwareȱ
3.ȱFollowȬMeȱ
4.1 Method
Thisȱoptionȱallowsȱyouȱtoȱconfigureȱtheȱparametersȱofȱtheȱcommunicationȱmethodsȱ
(channels)ȱofȱtheȱAgility.ȱ3ȱoptionalȱcommunicationȱtypesȱareȱavailable:ȱ
1.ȱPSTNȱ
2.ȱGSMȱ
3.ȱIPȱ
4.1.1 PSTN
TheȱPSTNȱscreenȱcontainsȱparametersȱforȱtheȱcommunicationȱofȱtheȱAgilityȱoverȱtheȱPSTNȱ
network
Communication Type: PSTN
Parameter
Default
Timersȱ
Range
ȱ
ȱ
TimersȱrelatedȱtoȱcommunicationȱthroughȱtheȱPSTNȱchannelȱ
PSTNȱLostȱDelayȱ
04ȱ
00Ȭ20ȱminutesȱ
TheȱtimeȱafterȱwhichȱtheȱsystemȱwillȱregardȱtheȱPSTNȱlineȱasȱlost.ȱThisȱtimeȱalsoȱ
specifiesȱtheȱdelayȱbeforeȱreportingȱtheȱeventȱintoȱtheȱeventȱlogȱorȱoperatingȱaȱ
programmingȱoutputȱthatȱfollowsȱthisȱevent.ȱȱ
00ȱindicatesȱnoȱsupervisionȱofȱtheȱphoneȱline.ȱ
WaitȱforȱDialȱToneȱ
3ȱ
0Ȭ255ȱsecondsȱ
Theȱnumberȱofȱsecondsȱtheȱsystemȱwaitsȱtoȱdetectȱaȱdialȱtone.ȱȱ
Controlsȱ
AlarmȱLineȱCutȱ
ȱ
ȱ
ȱ
ȱ
YES:ȱActivatesȱtheȱexternalȱsoundersȱifȱtheȱlandȱline,ȱconnectedȱtoȱtheȱAgilityȱ
panelȱisȱcutȱorȱtheȱtelephoneȱserviceȱisȱinterruptedȱforȱtheȱtimeȱdefinedȱinȱtheȱ
PSTNȱLostȱtimeȱparameter.ȱȱ
NO:ȱNoȱactivationȱoccurs.ȱ
Page 4-45
AgilityȱEngineerȱManualȱ
ȱ
Communication Type: PSTN
Parameter
Default
AnsweringȱMachineȱOverrideȱ
Range
ȱ
ȱ
YES:ȱTheȱAnsweringȱMachineȱOverrideȱisȱenabled,ȱasȱfollows:ȱ
Œ Theȱconfigurationȱsoftwareȱatȱtheȱalarmȱcompanyȱcallsȱtheȱaccount.ȱ
Œ Theȱsoftwareȱhangsȱupȱafterȱoneȱringȱbyȱtheȱconfigurationȱoperator.ȱ
Œ Withinȱoneȱminute,ȱtheȱsoftwareȱcallsȱagain.ȱ
Œ Theȱsystemȱisȱprogrammedȱtoȱpickȱupȱthisȱsecondȱcallȱonȱtheȱfirstȱring,ȱthusȱ
omittingȱanyȱinteractionȱwithȱtheȱansweringȱmachine.ȱ
Note:ȱThisȱfeatureȱisȱusedȱtoȱpreventȱinterferenceȱfromȱanȱansweringȱmachineȱwithȱremoteȱ
configurationȱoperations.ȱ
NO:ȱTheȱAnsweringȱMachineȱOverrideȱisȱdisabled,ȱandȱcommunicationȱtakesȱ
placeȱinȱtheȱstandardȱmanner.ȱ
Parametersȱ
RingsȱtoȱAnswerȱȱ
ȱ
ȱ
12ȱ
01ȱtoȱ15ȱ
Theȱnumberȱofȱringsȱbeforeȱtheȱsystemȱanswersȱanȱincomingȱcallȱȱ
Areaȱcodeȱ
ȱ
ȱ
Theȱsystemȱareaȱtelephoneȱcode.ȱThisȱcodeȱwillȱbeȱdeletedȱfromȱaȱtelephoneȱ
numberȱwhileȱtheȱsystemȱtriesȱtoȱdialȱtheȱnumberȱthroughȱtheȱGSMȱnetwork.ȱȱ
PBXȱPrefixȱ
ȱ
ȱ
Aȱnumberȱdialedȱtoȱaccessȱanȱoutgoingȱlineȱwhenȱtheȱsystemȱisȱconnectedȱtoȱaȱ
PrivateȱBranchȱExchangeȱ(PBX)ȱandȱnotȱdirectlyȱtoȱaȱPSTNȱline.ȱThisȱnumberȱ
willȱbeȱaddedȱautomaticallyȱbyȱtheȱsystemȱwhileȱtryingȱtoȱcallȱfromȱaȱPSTNȱline.ȱȱ
4.1.2 GSM
TheȱGSMȱscreenȱcontainsȱparametersȱforȱtheȱcommunicationȱofȱtheȱsystemȱoverȱtheȱ
GSM/GPRSȱnetwork.ȱ
Method: GSM
Parameter
Default
Range
Timersȱ
ȱ
ȱ
AllowsȱtoȱprogramȱtimersȱrelatedȱtoȱoperationȱwithȱtheȱGSMȱmoduleȱ
GSMȱLostȱ
10ȱmin
001Ȭ255ȱminȱ
TheȱtimeȱafterȱwhichȱtheȱGSMȱmoduleȱregardsȱtheȱGSMȱnetworkȱasȱloss.ȱ
NetworkȱlossȱisȱdefinedȱasȱRSSIȱlevelȱbelowȱtheȱlevelȱdefinedȱGSMȱNetworkȱ
Sensitivityȱparameter.ȱ
Page 4-46
AgilityȱEngineerȱManualȱ
ȱ
Method: GSM
Parameter
Default
SIMȱExpireȱ
Range
00ȱ
00Ȭ36ȱmonthsȱ
AȱPreȬpaidȱSIMȱcardȱhasȱaȱdefinedȱlifeȱlengthȱdefinedȱbyȱtheȱprovider.ȱAfterȱ
eachȱchargingȱofȱtheȱSIM,ȱtheȱuserȱwillȱhaveȱtoȱmanuallyȱresetȱtheȱexpirationȱ
timeȱofȱtheȱSIMȱcard.ȱAȱnotificationȱwillȱbeȱdisplayedȱonȱtheȱwirelessȱkeypadȱ
whenȱaskingȱforȱstatusȱindication.ȱ
SetȱtheȱSIMȱexpiringȱdateȱ(inȱmonths)ȱusingȱtheȱnumericȱkeys,ȱaccordingȱtoȱtheȱ
timeȱgivenȱbyȱtheȱprovider.ȱ
ARCȱKeepȱAliveȱ(Polling)ȱ
00000ȱ
0Ȭ65535ȱtimesȱ
Theȱtimeȱperiodȱthatȱtheȱsystemȱwillȱestablishȱautomaticȱcommunicationȱ
(polling)ȱwithȱtheȱARCȱoverȱGPRS,ȱinȱorderȱtoȱcheckȱtheȱconnection.ȱ
3ȱpollingȱtimesȱcanȱbeȱdefined:ȱPrimary,ȱSecondaryȱandȱBackup.ȱForȱeachȱtimeȱ
periodȱdefineȱtheȱnumberȱofȱunitsȱbetweenȱ1Ȭȱ65535.ȱEachȱunitȱrepresentsȱaȱtimeȱ
frameȱofȱ10ȱseconds.ȱ
Note:ȱWhenȱusingȱtheȱpollingȱfeatureȱthroughȱGPRSȱtheȱARCȱchannelȱparameterȱmustȱbeȱ
definedȱasȱGPRSȱonly.ȱ
TheȱreportȱcodeȱforȱARCȱpollingȱisȱ999ȱ(ContactȱID)ȱorȱZZȱ(SIA)ȱȱ
TheȱuseȱofȱtheseȱtimeȱperiodsȱdependsȱonȱtheȱreportingȱorderȱtoȱtheȱARCȱ
definedȱbyȱtheȱReportȱSplitȱARCȱUrgentȱparameterȱ(See:ȱ[4]Communicationȱ>ȱ
[2]ARCȱ>ȱ[7]ReportȱSplit)ȱ
Œ Primary:ȱThisȱtimeȱperiodȱisȱusedȱwhenȱtheȱARCȱchannelȱisȱdefinedȱasȱGPRSȱ
OnlyȱandȱtheȱReportȱSplitȱparameterȱisȱnotȱdefinedȱasȱ1stȱbackupȱ2nd.ȱ
Œ Secondary:ȱThisȱtimeȱperiodȱisȱusedȱwhenȱtheȱARCȱ2ȱchannelȱisȱdefinedȱasȱ
IPÆGPRSȱOnlyȱandȱtheȱReportȱSplitȱparameterȱisȱdefinedȱasȱ1stȱbackupȱ2nd.ȱ
Œ Backup:ȱThisȱtimeȱperiodȱwillȱbeȱassignedȱtoȱtheȱbackupȱchannelȱinȱtheȱ
followingȱcase:ȱ
ȱȱȱARCȱ2ȱchannelȱisȱdefinedȱasȱIPÆGPRSȱOnlyȱ
ȱȱȱReportȱSplitȱparameterȱisȱdefinedȱasȱ1stȱbackupȱ2ndȱ
ȱȱȱTheȱcommunicationȱwithȱARCȱ1ȱisȱdisconnected.ȱ
GPRSȱ
ȱ
ȱ
ȱ
AllowsȱprogrammingȱparametersȱthatȱrelateȱforȱtheȱcommunicationȱoverȱtheȱGPRSȱ
network.ȱ
Page 4-47
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Method: GSM
Parameter
Default
AccessȱPointȱNetworkȱ(APN)ȱCodeȱ
Range
ȱ
ȱ
ToȱestablishȱaȱconnectionȱtoȱtheȱGPRSȱnetworkȱanȱAPNȱ(AccessȱPointȱName)ȱ
codeȱisȱrequired.ȱTheȱAPNȱcodeȱdiffersȱfromȱcountryȱtoȱcountryȱandȱfromȱoneȱ
providerȱtoȱanotherȱ(theȱAPNȱcodeȱisȱprovidedȱbyȱyourȱcellularȱprovider).ȱ
TheȱsystemȱsupportsȱanȱAPNȱcodeȱfieldȱofȱupȱtoȱ30ȱalphanumericȱcharactersȱandȱ
symbolsȱ(!,ȱ&,ȱ?ȱetc).ȱ
APNȱUserȱNameȱ
ȱ
ȱ
EnterȱAPNȱuserȱnameȱ(ifȱrequired).ȱTheȱUserȱnameȱisȱprovidedȱbyȱyourȱ
provider.ȱTheȱsystemȱsupportsȱaȱuserȱnameȱfieldȱofȱupȱtoȱ20ȱalphanumericȱ
charactersȱandȱsymbolsȱ(!,ȱ&,ȱ?ȱetc).ȱ
APNȱPasswordȱ
ȱ
ȱ
EnterȱtheȱAPNȱpasswordȱ(upȱtoȱ20ȱalphanumericȱcharactersȱandȱsymbols.)ȱasȱ
providedȱbyȱyourȱproviderȱ(ifȱrequired).ȱ
EȬmailȱ
ȱ
ȱ
TheȱfollowingȱprogrammingȱparametersȱareȱusedȱtoȱenableȱsendingȱFollowȱMeȱeventȱ
messagesȱbyȱeȬmailȱthroughȱGPRS.ȱ
Note:ȱToȱenableȱeȬmailȱmessaging,ȱtheȱGPRSȱparametersȱhaveȱtoȱbeȱdefined.ȱ
MailȱHostȱ
ȱ
ȱ
TheȱIPȱaddressȱorȱtheȱhostȱnameȱofȱtheȱSMTPȱmailȱserverȱ
SMTPȱPortȱ
ȱ
ȱ
ȱ
ȱ
TheȱportȱaddressȱofȱtheȱSMTPȱmailȱserverȱ
Emailȱaddressȱ
TheȱEmailȱaddressȱthatȱidentifiesȱtheȱsystemȱtoȱtheȱmailȱrecipientȱ.ȱȱ
SMTPȱUserȱNameȱ
ȱ
ȱ
AȱnameȱidentifyingȱtheȱuserȱtoȱtheȱSMTPȱmailȱserver.ȱTheȱuserȱnameȱfieldȱcanȱ
includeȱupȱtoȱ10ȱalphanumericȱcharactersȱandȱsymbolsȱ(!,ȱ&,ȱ?ȱetc).ȱProvisionȱforȱ
futureȱfunctionalityȱ
SMTPȱPasswordȱ
ȱ
ȱ
TheȱpasswordȱauthenticatingȱtheȱuserȱtoȱtheȱSMTPȱmailȱserver.ȱTheȱpasswordȱ
canȱincludeȱupȱtoȱ10ȱalphanumericȱcharactersȱandȱsymbolsȱ(!,ȱ&,ȱ?ȱetc).ȱProvisionȱ
forȱfutureȱfunctionalityȱ
Page 4-48
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Method: GSM
Parameter
Default
Range
Controlsȱ
ȱ
ȱ
AllowsȱtoȱcontrolȱtimersȱrelatedȱtoȱoperationȱwithȱtheȱGSMȱmoduleȱ
CallerȱIDȱ
ȱ
ȱ
TheȱCallerȱIDȱfunctionȱenablesȱtoȱrestrictȱSMSȱremoteȱcontrolȱoperationsȱtoȱtheȱ
predefinedȱfollowȱmeȱphoneȱnumbers.ȱIfȱtheȱincomingȱnumberȱisȱrecognizedȱasȱ
oneȱofȱtheȱFollowȱMeȱnumbers,ȱtheȱoperationȱwillȱbeȱexecuted.ȱ
DisableȱGSMȱ
ȱ
ȱ
YES:ȱTheȱsystemȱwillȱdisableȱtheȱGSM/GPRSȱmoduleȱfromȱanyȱactivity.ȱȱ
NO:ȱGSM/GPRSȱmoduleȱisȱenabledȱinȱtheȱsystem.ȱ
Parametersȱ
ȱ
ȱ
AllowsȱtoȱprogramȱtimersȱrelatedȱtoȱtheȱoperationȱwithȱtheȱGSMȱmodule.ȱ
SIMȱPINȱCodeȱ
ȱ
ȱ
TheȱPINȱ(PersonalȱIdentityȱNumber)ȱcodeȱisȱaȱ4ȱtoȱ8ȱdigitȱnumberȱgivingȱyouȱ
accessȱtoȱtheȱGSMȱnetworkȱprovider.ȱ
Note:ȱYouȱcanȱcancelȱtheȱPINȱcodeȱrequestȱfunctionȱbyȱinsertingȱtheȱSIMȱcardȱintoȱaȱregularȱȱ
mobileȱphoneȱandȱaccordingȱtoȱtheȱphoneȱsettings,ȱdisableȱthisȱfunction.ȱ
SMSȱCenterȱPhoneȱ
ȱ
ȱ
Aȱtelephoneȱnumberȱofȱtheȱmessageȱdeliveryȱcenter.ȱThisȱnumberȱcanȱbeȱ
obtainedȱfromȱtheȱnetworkȱoperator.ȱȱ
GSMȱNetworkȱSensitivityȱ(RSSI)ȱ
ȱ
ȱ
Setȱtheȱminimumȱacceptableȱnetworkȱsignalȱlevelȱ(RSSIȱlevel). ȱ
Options:ȱDisabledȱ(Noȱtroublesȱforȱlowȱsignalȱreception)ȱ/ȱLowȱsignalȱ/ȱHighȱ
signalȱȱ
SIMȱNumberȱ
ȱ
ȱ
TheȱSIMȱphoneȱnumber.ȱTheȱsystemȱusesȱthisȱparameterȱtoȱreceiveȱtheȱtimeȱfromȱ
theȱGSMȱnetworkȱinȱorderȱtoȱupdateȱtheȱsystemȱtime.
Page 4-49
AgilityȱEngineerȱManualȱ
ȱ
Method: GSM
Parameter
Default
PrepaidȱSIMȱCardȱ
Range
ȱ
ȱ
AllowsȱprogrammingȱparametersȱthatȱwillȱbeȱusedȱwhenȱaȱprepaidȱSIMȱcardȱisȱusedȱinȱ
theȱsystem.ȱ
ȱȱȱȱȱȱȱȱGetȱCreditȱbyȱȱ
ȱ
ȱ
Dependingȱonȱtheȱlocalȱnetworkȱprovider,ȱtheȱuserȱcanȱreceiveȱtheȱcreditȱlevelȱofȱtheȱ
prepaidȱSIMȱcardȱbyȱsendingȱaȱpredefinedȱSMSȱcommandȱtoȱaȱdefinedȱnumberȱorȱbyȱ
callingȱaȱpredefinedȱnumberȱthroughȱtheȱvoiceȱchannel.ȱȱTheȱactivationȱofȱtheȱcreditȱ
requestȱcanȱbeȱdoneȱbyȱtheȱGrandȱMaster.ȱ
Œ SMSȱCreditȱMessage:ȱTypeȱinȱtheȱmessageȱcommandȱasȱdefinedȱbyȱtheȱ
providerȱȱandȱtheȱprovider’sȱphoneȱnumberȱtoȱwhichȱtheȱcreditȱlevelȱSMSȱ
messageȱrequestȱwillȱbeȱsent.ȱ
Œ VoiceȱCredit:ȱTypeȱinȱtheȱprovider’sȱphoneȱnumberȱtoȱwhichȱaȱcallȱwillȱbeȱ
establishedȱ
Œ ServiceȱCommand:ȱTypeȱinȱtheȱserviceȱcommandȱmessageȱasȱdefinedȱbyȱtheȱ
providerȱȱ
ȱȱȱȱȱȱȱPhoneȱtoȱGetȱCreditȱMessageȱ
ȱ
ȱ
ȱȱȱȱȱȱȱTheȱprovider’sȱphoneȱnumberȱtoȱwhichȱtheȱcreditȱlevelȱSMSȱmessageȱrequestȱȱ
ȱȱȱȱȱȱȱwillȱbeȱsentȱtoȱorȱaȱcallȱwillȱbeȱestablished,ȱdependingȱonȱtheȱselectionȱinȱtheȱȱȱ
ȱȱȱȱȱȱȱGetȱCreditȱbyȱparameter.ȱ
ȱȱȱȱȱȱȱȱPhoneȱtoȱReceiveȱSMSȱCreditȱMessage:ȱ
ȱ
ȱ
Theȱprovider’sȱtelephoneȱnumberȱfromȱwhichȱanȱautomaticȱSMSȱcreditȱstatusȱ
messageȱwillȱbeȱsentȱfrom.ȱ
4.1.3 IP
Communication Type: IP
Parameter
Default
IPȱConfigurationȱ
ObtainȱAutomaticȱIPȱ
Range
ȱ
ȱ
YESȱ
Y/Nȱ
DefinesȱwhetherȱtheȱIPȱaddress,ȱwhichȱtheȱAgilityȱrefersȱto,ȱisȱstaticȱorȱdynamic.ȱ
YES:ȱTheȱsystemȱrefersȱtoȱanȱIPȱaddressȱprovidedȱbyȱtheȱDHCP.ȱ
NO:ȱTheȱsystemȱrefersȱtoȱaȱstaticȱIPȱAddress.ȱ
PanelȱIPȱ
ȱ
ȱ
TheȱAgilityȱIPȱaddress
SubnetȱMaskȱ
TheȱsubnetȱmaskȱisȱusedȱtoȱdetermineȱwhereȱtheȱnetworkȱnumberȱinȱanȱIPȱ
addressȱends.ȱȱ
Page 4-50
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Communication Type: IP
Parameter
Default
Range
Gatewayȱ
TheȱIPȱaddressȱofȱtheȱlocalȱGateway,ȱwhichȱenablesȱcommunicationȱsettingsȱtoȱ
otherȱLANȱsegments.ȱThisȱaddressȱisȱtheȱIPȱaddressȱofȱtheȱrouterȱconnectedȱtoȱ
theȱsameȱLANȱsegmentȱasȱtheȱAgility.ȱ
DNSȱPrimaryȱ
TheȱIPȱaddressȱofȱtheȱprimaryȱDNSȱserverȱonȱtheȱnetwork.ȱȱ
DNSȱSecondaryȱ
TheȱIPȱaddressȱofȱtheȱsecondaryȱȱDNSȱserverȱonȱtheȱnetworkȱ
EȬmailȱ
ȱ
ȱ
AllowsȱprogrammingȱparametersȱthatȱenableȱtheȱAgilityȱtoȱsendȱEmailȱmessagesȱ
followingȱFollowȱMeȱeventsȱ
MailȱHostȱ
ȱ
ȱ
ȱ
ȱ
TheȱIPȱaddressȱorȱtheȱHostȱnameȱofȱtheȱmailȱserver.ȱ
SMTPȱPortȱ
TheȱportȱaddressȱofȱtheȱSMTPȱmailȱserver.ȱDefault:ȱ00025
EȬmailȱaddressȱ
ȱ
ȱ
AgilityȱEȬmailȱaddress.ȱDefault:ȱYourCompany.comȱ
SMTPȱUserȱnameȱ
Ifȱrequiredȱbyȱtheȱmailȱserver,ȱfillȱinȱtheȱAuthenticationȱUserȱnameȱ
SMTPȱUserȱpasswordȱ
Ifȱrequiredȱbyȱtheȱmailȱserver,ȱfillȱinȱtheȱAuthenticationȱUserȱpasswordȱ
HostȱNameȱ
ȱ
(Upȱtoȱ32ȱcharacters)ȱ
IPȱaddressȱorȱaȱtextȱnameȱusedȱtoȱidentifyȱtheȱAgilityȱoverȱtheȱnetwork.ȱ
Default:ȱSecurityȱSystemȱ
ȱ
ȱ
Page 4-51
AgilityȱEngineerȱManualȱ
ȱ
Communication Type: IP
Parameter
Default
ARCȱKeepȱAliveȱ(Polling)ȱ
Range
00000ȱ
0Ȭ65535ȱ
Theȱtimeȱperiodȱthatȱtheȱsystemȱwillȱestablishȱautomaticȱcommunicationȱ(polling)ȱwithȱ
theȱARCȱoverȱtheȱIPȱnetwork,ȱinȱorderȱtoȱcheckȱtheȱconnection.ȱ
3ȱpollingȱtimesȱcanȱbeȱdefined:ȱPrimary,ȱSecondaryȱandȱBackup.ȱForȱeachȱtimeȱperiodȱ
defineȱtheȱnumberȱofȱunitsȱbetweenȱ1Ȭȱ65535.ȱEachȱunitȱrepresentsȱaȱtimeȱframeȱofȱ10ȱ
seconds.ȱ
Note:ȱWhenȱusingȱtheȱpollingȱfeatureȱthroughȱIP,ȱtheȱARCȱchannelȱparameterȱmustȱbeȱdefinedȱasȱIPȱonly.ȱ
TheȱuseȱofȱtheseȱtimeȱperiodsȱdependsȱonȱtheȱreportingȱorderȱtoȱtheȱARCȱdefinedȱbyȱtheȱ
ReportȱSplitȱARCȱUrgentȱparameterȱ(See:ȱ[4]Communicationȱ>ȱ[2]ARCȱ>ȱ[7]ReportȱSplit)ȱ
Œ Primary:ȱThisȱtimeȱperiodȱisȱusedȱwhenȱtheȱARCȱchannelȱisȱdefinedȱasȱIPȱ
OnlyȱandȱtheȱReportȱSplitȱparameterȱisȱnotȱdefinedȱasȱ1stȱbackupȱ2nd.ȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ
Default:ȱ00006ȱ(60ȱseconds)ȱ
Œ Secondary:ȱThisȱtimeȱperiodȱisȱusedȱwhenȱtheȱARCȱ2ȱchannelȱisȱdefinedȱasȱ
IPÆIPȱȱOnlyȱandȱtheȱReportȱSplitȱparameterȱisȱdefinedȱasȱ1stȱbackupȱ2nd.ȱ
Default:ȱ360ȱ(3600ȱseconds)ȱ
Œ Backup:ȱThisȱtimeȱperiodȱwillȱbeȱassignedȱtoȱtheȱbackupȱchannelȱinȱtheȱ
followingȱcase:ȱ
ȱȱȱARCȱ2ȱchannelȱisȱdefinedȱasȱIPÆIPȱOnlyȱ
ȱȱȱReportȱSplitȱparameterȱisȱdefinedȱasȱ1stȱbackupȱ2ndȱ
ȱȱȱTheȱcommunicationȱwithȱARCȱ1ȱisȱdisconnected.ȱ
ȱȱȱȱȱȱȱȱDefault:ȱ00006ȱ(60ȱseconds)ȱ
Controlsȱ
DisableȱIPȱ
ȱ
ȱ
ȱ
ȱ
YES:ȱTheȱsystemȱwillȱdisableȱtheȱIPȱmoduleȱfromȱanyȱactivity.ȱ
NO:ȱTheȱIPȱmoduleȱisȱenabledȱinȱtheȱsystemȱ
Page 4-52
AgilityȱEngineerȱManualȱ
ȱ
ȱ
4.2 Alarm Receiving Center
TheȱAlarmȱReceivingȱCenterȱmenuȱcontainsȱparametersȱthatȱenableȱtheȱsystemȱtoȱestablishȱ
communicationȱwithȱtheȱARCȱandȱtransmitȱdata.ȱ
Communication: ARC
Parameter
Default
ReportȱTypeȱ
ȱ
Range
ȱ
Typeȱ
Definesȱtheȱcommunicationȱtypeȱthatȱtheȱsystemȱwillȱestablishȱwithȱeachȱalarmȱ
receivingȱcenter.ȱTheȱsystemȱcanȱreportȱinȱ3ȱoptionalȱcommunicationȱtypes:ȱ
Œ Voiceȱȱ
Œ SMSȱ
Œ IPȱ
Voiceȱ
ReportsȱtoȱtheȱalarmȱreceivingȱcenterȱwillȱbeȱdoneȱthroughȱtheȱPSTNȱorȱ
GSMȱnetwork.ȱReportingȱbyȱVoiceȱcanȱbeȱestablishedȱthroughȱdifferentȱ
channels.ȱTheȱoptionalȱchannelsȱdependȱonȱtheȱhardwareȱinstalledȱinȱ
yourȱsystem.ȱSelectȱtheȱrequiredȱchannelȱasȱfollows:ȱ
x
x
x
x
PSTN/GSM:ȱȱTheȱsystemȱchecksȱforȱtheȱavailabilityȱofȱtheȱPSTNȱline.ȱDuringȱ
regularȱoperationȱmodeȱallȱcallsȱandȱdataȱtransmissionȱareȱcarriedȱoutȱusingȱ
theȱPSTNȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱtheȱPSTNȱline,ȱtheȱlineȱisȱroutedȱtoȱtheȱ
GSMȱline.ȱ
GSM/PSTN:ȱTheȱpanelȱchecksȱforȱtheȱavailabilityȱofȱtheȱGSMȱline.ȱDuringȱ
regularȱoperationȱmodeȱallȱcallsȱandȱdataȱtransmissionȱareȱcarriedȱoutȱusingȱ
theȱGSMȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱtheȱGSMȱline,ȱtheȱlineȱisȱroutedȱtoȱtheȱ
PSTNȱline.ȱ
PSTNȱOnly:ȱTheȱoutgoingȱcallsȱareȱexecutedȱthroughȱtheȱPSTNȱaudioȱ
channelȱonly.ȱUseȱthisȱoptionȱforȱinstallationsȱwhereȱnoȱGSMȱlineȱisȱ
available.ȱ
GSMȱOnly:ȱTheȱoutgoingȱcallsȱareȱexecutedȱthroughȱtheȱGSMȱaudioȱchannelȱ
only.ȱUseȱthisȱoptionȱforȱinstallationsȱwhereȱnoȱPSTNȱlineȱisȱavailable.ȱ
Enterȱtheȱalarmȱreceivingȱcenterȱtelephoneȱnumberȱincludingȱareaȱcodeȱ
andȱspecialȱlettersȱ(ifȱrequired).ȱIfȱcallingȱfromȱPBXȱdoȱnotȱincludeȱtheȱ
numberȱforȱoutgoingȱline.ȱȱ
Function
Results
Stopȱdialingȱandȱwaitȱforȱaȱnewȱdialȱtoneȱ
Wȱ
Waitȱaȱfixedȱperiodȱbeforeȱcontinuingȱ
SendȱtheȱDTMFȱ¾ȱcharacterȱ
,ȱ
¾ȱ
SendȱtheȱDTMFȱ#ȱcharacterȱ
#ȱ
Deleteȱnumbersȱfromȱtheȱcursorȱpositionȱ
ȱ
[¾]ȱ[0]ȱsimultaneouslyȱȱ
Page 4-53
AgilityȱEngineerȱManualȱ
ȱ
Communication: ARC
Parameter
Default
Range
SMSȱ
EventsȱareȱsentȱtoȱtheȱalarmȱreceivingȱcenterȱusingȱencryptedȱSMSȱ
messagesȱ(128ȱBITȱAESȱencryption).ȱEachȱeventȱmessageȱcontainsȱ
informationȱincludingȱtheȱaccountȱnumber,ȱreportȱcode,ȱcommunicationȱ
format,ȱtimeȱofȱeventȱandȱmore.ȱTheȱeventȱmessagesȱareȱreceivedȱbyȱ
RISCOȱGroupȇsȱIP/GSMȱReceiverȱSoftwareȱlocatedȱatȱtheȱARCȱsite.ȱTheȱ
IP/GSMȱReceiverȱtranslatesȱtheȱSMSȱmessagesȱtoȱstandardȱprotocolsȱ
usedȱbyȱtheȱalarmȱreceivingȱcenterȱapplicationsȱ(Forȱexample;ȱContactȱ
ID).ThisȱchannelȱrequiresȱthatȱRISCOȱGroup’sȱIP/GSMȱreceiverȱhasȱtoȱbeȱ
usedȱatȱtheȱARCȱside.ȱȱ
EnterȱtheȱrelevantȱphoneȱnumbersȱforȱtheȱARCȱthatȱwillȱreceiveȱreportsȱ
fromȱtheȱsystem.ȱ(SeeȱexplanationȱinȱVoiceȱtypeȱonȱpageȱ4Ȭ53)ȱ
IPȱ
EncryptedȱeventsȱareȱsentȱtoȱtheȱalarmȱreceivingȱcenterȱoverȱtheȱIPȱorȱ
GPRSȱnetworkȱusingȱTCP/IPȱprotocol.ȱ128ȱBITȱAESȱencryptionȱisȱused.ȱ
RISCOȱGroupȇsȱIP/GSMȱReceiverȱSoftwareȱlocatedȱatȱtheȱARCȱsiteȱ
receivesȱtheȱmessagesȱandȱtranslatesȱthemȱtoȱstandardȱprotocolsȱusedȱbyȱ
theȱalarmȱreceivingȱcenterȱapplicationsȱ(Forȱexample;ȱContactȱID).ȱȱ
Note:ȱToȱenableȱGPRSȱcommunicationȱtheȱSIMȱcardȱhasȱtoȱsupportȱGPRSȱchannelȱ
ReportingȱbyȱIPȱcanȱbeȱestablishedȱthroughȱdifferentȱchannels.ȱTheȱ
optionalȱchannelsȱdependȱonȱtheȱhardwareȱinstalledȱinȱyourȱsystem.ȱ
SelectȱtheȱrequiredȱchannelȱviaȱtheȱConfigurationȱSoftwareȱasȱfollows:ȱ
x
x
x
x
IP/GPRS:ȱȱTheȱpanelȱchecksȱforȱtheȱavailabilityȱofȱtheȱIPȱnetwork.ȱDuringȱ
regularȱoperationȱmodeȱallȱcallsȱandȱdataȱtransmissionȱareȱcarriedȱoutȱusingȱ
theȱIPȱnetworkȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱtheȱIPȱnetwork,ȱtheȱreportȱisȱroutedȱ
toȱtheȱGPRSȱnetwork.ȱ
GPRS/IP:ȱȱTheȱpanelȱchecksȱforȱtheȱavailabilityȱofȱtheȱGPRSȱnetwork.ȱDuringȱ
regularȱoperationȱmodeȱallȱcallsȱandȱdataȱtransmissionȱareȱcarriedȱoutȱusingȱ
theȱGPRS.ȱInȱtheȱcaseȱofȱfaultȱtheȱreportȱisȱroutedȱtoȱtheȱIPȱnetwork.ȱ
IPȱOnly:ȱTheȱreportȱisȱexecutedȱthroughȱtheȱIPȱnetworkȱonly.ȱ
GPRSȱOnly:ȱTheȱreportȱisȱexecutedȱthroughȱtheȱGPRSȱnetwork.ȱ
EnterȱtheȱrelevantȱIPȱandȱPortȱnumbersȱforȱtheȱARCȱthatȱwillȱreceiveȱ
reportsȱfromȱtheȱsystem.ȱ(SeeȱIPȱandȱPort)ȱ
Page 4-54
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Communication: ARC
Parameter
Default
Range
Accountsȱ
AccountȱNumberȱ
Theȱnumberȱthatȱrecognizesȱtheȱcustomerȱatȱtheȱalarmȱreceivingȱcenter.ȱYouȱcanȱ
defineȱanȱaccountȱnumberȱforȱeachȱalarmȱreceivingȱcenter.ȱTheseȱaccountȱ
numbersȱareȱtheȱ6Ȭdigitȱnumbersȱassignedȱbyȱtheȱcentralȱstation.ȱ
NotesȱforȱAccountȱNumberȱinȱContactȱIDȱCommunicationȱFormat:ȱȱ
1.
Theȱaccountȱnumberȱwillȱalwaysȱbeȱreportedȱasȱ4ȱdigits,ȱȱforȱexample:ȱAȱnumberȱ
definedȱasȱ000012ȱwillȱbeȱreportedȱasȱ0012ȱ
2.
Ifȱmoreȱthanȱ4ȱdigitsȱwereȱdefined,ȱtheȱsystemȱalwaysȱsendsȱtheȱlastȱ4ȱdigitsȱofȱtheȱ
accountȱnumber,ȱforȱexample:ȱAccountȱnumberȱthatȱwasȱdefinedȱasȱ123456ȱwillȱbeȱsentȱ
asȱ3456.ȱȱ
3.
InȱContactȱIDȱyouȱcanȱplaceȱdigitsȱandȱlettersȱAȬF.ȱTheȱAȱcharacterȱisȱalwaysȱsentȱasȱ0ȱ
forȱexample:ȱAccountȱnumberȱthatȱwasȱdefinedȱasȱ00C2ABȱwillȱbeȱsentȱasȱC20B.ȱ
NotesȱforȱAccountȱNumberȱinȱSIAȱCommunicationȱFormat:ȱȱ
1.
AccountȱnumberȱforȱSIAȱshouldȱbeȱdefinedȱasȱaȱdecimalȱnumberȱ(Onlyȱdigitsȱ0..9)ȱ
2.
Accountȱnumberȱcanȱbeȱreportedȱasȱ1ȱtoȱ6ȱdigits.ȱToȱsendȱanȱaccountȱnumberȱwithȱlessȱ
thanȱ6ȱdigitsȱuseȱtheȱ“0”ȱdigit,ȱforȱexample:ȱForȱaccountȱnumberȱ1234ȱenterȱ001234.ȱInȱ
thisȱcaseȱtheȱsystemȱwillȱnotȱsendȱtheȱ“0”ȱdigitȱtoȱtheȱARC.ȱ
3.ȱȱȱȱȱȱInȱorderȱtoȱsendȱtheȱ“0”ȱdigitȱinȱSIAȱformat,ȱlocatedȱatȱtheȱleftȱsideȱofȱtheȱnumber,ȱuseȱȱ
ȱȱȱȱȱȱȱȱȱtheȱ“A”ȱdigitȱinsteadȱofȱtheȱ“0”ȱdigit.ȱForȱexample,ȱforȱaccountȱnumberȱ0407ȱenterȱȱ
ȱȱȱȱȱȱȱȱȱ00A407,ȱforȱaȱ6ȱdigitȱaccountȱnumberȱsuchȱasȱ001207ȱenterȱAA1207.ȱ
CommunicationsȱFormatȱ
EnablesȱtheȱsystemȱtoȱcontactȱtheȱARCȱinȱorderȱtoȱobtainȱdetailsȱofȱtheȱ
communicationȱprotocolȱusedȱbyȱtheȱdigitalȱreceiverȱforȱeachȱaccount.ȱ
Theȱcodesȱareȱautomaticallyȱuploadedȱwhenȱtheȱcommunicationȱformatȱhasȱbeenȱ
selected:ȱ
Œ ContactȱID:ȱTheȱsystemȱallocatesȱReportȱCodesȱsupportingȱADEMCOȱContactȱ
(Point)ȱIDȱ
Œ SIA:ȱTheȱsystemȱallocatesȱReportȱCodesȱsupportingȱtheȱSIAȱ(SecurityȱIndustryȱ
Association)ȱformatȱȱ
Note:ȱSeeȱAppendixȱAȱforȱtheȱreportȱcodesȱlist.ȱ
Controlsȱ
AllowsȱtoȱprogramȱcontrolȱrelatedȱtoȱoperationȱwithȱtheȱARC.ȱ
Page 4-55
AgilityȱEngineerȱManualȱ
ȱ
Communication: ARC
Parameter
Default
Handshakeȱ
Range
NOȱ
ȱ
YES:ȱAllȱLEDsȱonȱtheȱAgilityȱmainȱunitȱlightȱforȱoneȱsecondȱwhenȱtheȱhandshakeȱ
signalȱisȱreceivedȱfromȱtheȱCentralȱStationȇsȱreceiver.ȱ
NO:ȱNoȱindicationȱforȱestablishingȱcommunicationȱwithȱtheȱCentralȱStationȇsȱ
receiver.ȱ
KissȬOffȱY/Nȱ
NOȱ
ȱ
YES:ȱAllȱLEDsȱonȱtheȱAgilityȱmainȱunitȱlightȱforȱoneȱsecondȱandȱanȱaudibleȱsoundȱ
isȱemittedȱwhenȱtheȱkissȬoffȱsignalȱisȱreceivedȱfromȱtheȱCentralȱStationȇsȱreceiver.ȱ
NO:ȱNoȱindicationȱforȱestablishingȱcommunicationȱwithȱtheȱCentralȱStationȇsȱ
receiver.ȱ
Parametersȱ
AllowsȱtoȱprogramȱparametersȱrelatedȱtoȱoperationȱwithȱtheȱARC.ȱ
ARCȱRetriesȱ
08ȱ
01Ȭ15ȱ
TheȱnumberȱofȱtimesȱtheȱsystemȱredialsȱtheȱARCȱafterȱfailingȱtoȱestablishȱ
communication.ȱ
AlarmȱRestoreȱ
CTOȱ
ȱ
SpecifiesȱunderȱwhatȱconditionsȱanȱAlarmȱRestoralȱisȱreported.ȱThisȱoptionȱ
informsȱtheȱARCȱofȱaȱchangeȱinȱtheȱspecifiedȱcondition(s)ȱduringȱanȱalarmȱrestore.ȱ
TheseȱreportsȱneedȱaȱvalidȱReportȱCode.ȱ
Œ OnȱConfirmationȱTimeȱOutȱ(CTO)ȱȬȱReportsȱtheȱrestoralȱofȱaȱconfirmedȱzoneȱatȱ
theȱendȱofȱtheȱConfirmationȱTimeȱWindowȱ(Seeȱpageȱ4Ȭ57)ȱ.ȱ
Œ FollowȱZoneȱȬȱReportsȱtheȱrestoralȱwhenȱtheȱzoneȱinȱwhichȱtheȱalarmȱoccursȱ
returnsȱtoȱitsȱnonȬviolatedȱ(secured)ȱstate.ȱ
Œ AtȱUnsetȱȬȱReportsȱtheȱrestoralȱwhenȱtheȱsystemȱ(orȱtheȱpartitionȱinȱwhichȱtheȱ
alarmȱoccurs)ȱisȱunset,ȱevenȱifȱtheȱsounderȱhasȱalreadyȱtimedȱout.ȱ
ARCȱTimersȱ
ȱ
ȱ
AllowsȱtoȱprogramȱtimersȱrelatedȱtoȱoperationȱwithȱtheȱARC.ȱ
PeriodicȱTestȱ
ȱ
ȱ
TheȱPeriodicȱTestȱenablesȱyouȱtoȱsetȱtheȱtimeȱperiodȱthatȱtheȱsystemȱwillȱ
automaticallyȱestablishȱcommunicationȱtoȱtheȱARCȱinȱorderȱtoȱcheckȱtheȱ
connection.ȱTheȱperiodicȱtestȱinvolvesȱsendingȱtheȱaccountȱnumberȱandȱaȱvalidȱ
testȱreportȱcodeȱ(ContactȱIDȱ602,ȱSIAȱTX).ȱȱSetȱtheȱtestȱtimeȱandȱdailyȱintervalȱforȱ
PeriodicȱTestȱReporting.ȱȱ
Page 4-56
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Communication: ARC
Parameter
Default
AbortȱAlarmȱȱ
15ȱsecȱ
Range
0Ȭ255ȱsecȱ
DefinesȱtheȱtimeȱdelayȱbeforeȱreportingȱanȱalarmȱtoȱtheȱARC.ȱIfȱtheȱalarmȱsystemȱ
isȱUnsetȱwithinȱtheȱAbortȱWindow,ȱnoȱalarmȱtransmissionȱshallȱbeȱsentȱtoȱtheȱ
ARC.ȱ
CancelȱDelayȱȱ
5ȱminȱ
0Ȭ255ȱminȱ
Ifȱanȱalarmȱisȱsentȱinȱerror,ȱitȱisȱpossibleȱforȱtheȱARCȱtoȱreceiveȱaȱCancelȱAlarmȱ
Code,ȱsentȱsubsequentlyȱtoȱtheȱinitialȱAlarmȱCode.ȱThisȱhappensȱifȱaȱvalidȱUserȱ
CodeȱisȱenteredȱtoȱresetȱtheȱalarmȱinȱtheȱCancelȱDelayȱtimeȱwindowȱthatȱstartsȱ
afterȱtheȱdefinedȱAbortȱAlarmȱtimeȱisȱover.ȱȱ
Note:ȱCancelȱAlarmȱreportȱcodeȱshouldȱbeȱdefined.ȱ
ListenȱInȱ
120ȱ
1Ȭ240ȱsecondsȱ
TheȱtimeȱdurationȱforȱtheȱalarmȱreceivingȱcenterȱtoȱListenȱinȱandȱperformȱvoiceȱ
alarmȱverification.ȱAfterȱthisȱperiodȱtheȱsystemȱhangsȱupȱtheȱline.ȱȱ
TheȱARCȱcanȱexpandȱtheȱlistenȱinȱtimeȱduringȱtheȱconversationȱbyȱpressingȱtheȱ
digitȱȈ1Ȉȱonȱtheȱtelephone.ȱInȱthisȱcase,ȱtheȱListenȱInȱtimeȱwillȱresetȱandȱstartȱoverȱ
again.ȱ
Confirmationȱ
ȱ
ȱ
TheȱconfirmationȱtimesȱrelateȱtoȱtheȱZoneȱSequentialȱConfirmation.ȱ
ConfirmȱStartȱ(Confirmȱdelayȱtime)ȱ
0ȱ
0Ȭ120ȱminȱ
Specifiesȱthatȱtheȱsystemȱcannotȱstartȱaȱsequentialȱconfirmationȱprocessȱ
untilȱtheȱtimerȱhasȱexpired.ȱThisȱtimeȱstartsȱwhenȱtheȱsystemȱhasȱsetȱandȱ
willȱpreventȱconfirmedȱalarmsȱbeingȱgeneratedȱinȱsituationsȱwhenȱaȱ
personȱhasȱbeenȱaccidentallyȱlockedȱinȱtheȱbuilding.ȱ
ConfirmȱTimeȱWindowȱ
030ȱ
30Ȭ60ȱminȱ
Specifiesȱaȱtimeȱperiodȱthatȱstartsȱwhenȱanȱalarmȱisȱtriggeredȱforȱtheȱfirstȱ
time.ȱIfȱaȱsecondȱalarmȱisȱtriggeredȱbeforeȱtheȱendȱofȱtheȱconfirmationȱ
timeȱwindow,ȱtheȱsystemȱwillȱsendȱaȱconfirmedȱalarmȱtoȱtheȱalarmȱ
receivingȱcenter.ȱ
NoȱȱSetȱ
0ȱ
0Ȭ12ȱweeksȱ
Aȱ Noȱ Setȱ codeȱ willȱ beȱ sentȱ toȱ theȱ ARCȱ ifȱ noȱ settingȱ orȱ unsettingȱ hasȱ beenȱ
establishedȱduringȱtheȱtimeȱdefinedȱ(1Ȭ12ȱweeks).ȱ
(0=notȱactivated)ȱ
ReportȱSplitȱȱ
ȱ
ȱ
TheȱReportȱSplitȱmenuȱcontainsȱparametersȱthatȱenableȱtheȱroutingȱofȱspecifiedȱeventsȱtoȱ
upȱtoȱthreeȱARCȱReceivers.ȱ(SeeȱAppendixȱAȱReportsȱCodes)ȱ
Page 4-57
AgilityȱEngineerȱManualȱ
ȱ
Communication: ARC
Parameter
Default
ARCȱSet/Unsetȱ
ȱ
Range
ȱ
ReportsȱSetting/Unsettingȱ(meaningȱClosings/Openings)ȱeventsȱtoȱtheȱARCȱ
Œ Doȱnotȱcallȱ(noȱreport)ȱ
Œ Callȱ1st:ȱReportsȱOpeningsȱandȱClosingsȱtoȱARCȱ1ȱ
Œ Callȱ2nd:ȱReportsȱOpeningsȱandȱClosingsȱtoȱARCȱ2ȱ
Œ Callȱ3rd:ȱReportsȱOpeningsȱandȱClosingsȱtoȱARCȱ3ȱ
Œ Callȱall:ȱReportsȱOpeningsȱandȱClosingsȱtoȱallȱdefinedȱARC.ȱ
Œ 1stȱBackupȱ2nd:ȱReportsȱOpeningsȱandȱClosingsȱtoȱARCȱ1.ȱIfȱcommunicationȱisȱ
notȱestablished,ȱcallsȱARCȱ2.ȱ
ARCȱUrgentȱ
ȱ
ȱ
Reportsȱurgentȱ(alarm)ȱeventsȱtoȱtheȱARCȱ
Œ Doȱnotȱcallȱ(noȱreport)ȱ
Œ Callȱ1st:ȱReportsȱurgentȱeventsȱtoȱARCȱ1ȱ
Œ Callȱ2nd:ȱReportsȱurgentȱeventsȱtoȱARCȱ2ȱ
Œ Callȱ3rd:ȱReportsȱurgentȱeventsȱtoȱARCȱ3ȱ
Œ Callȱall:ȱReportsȱurgentȱeventsȱtoȱallȱdefinedȱARC.ȱ
Œ 1stȱBackupȱ2nd:ȱReportsȱurgentȱeventsȱtoȱARCȱ1.ȱIfȱcommunicationȱisȱnotȱ
established,ȱcallsȱARCȱ2ȱ
ARCȱNonȱUrgentȱ
ȱ
ȱ
ReportsȱnonȬurgentȱeventsȱ(faultsȱandȱtestȱreports)ȱtoȱtheȱARCȱ
Œ Doȱnotȱcallȱ(noȱreport)ȱ
Œ Callȱ1st:ȱReportsȱnonȬurgentȱeventsȱtoȱARCȱ1ȱ
Œ Callȱ2nd:ȱReportsȱnonȬurgentȱeventsȱtoȱARCȱ2ȱ
Œ Callȱ3rd:ȱReportsȱnonȬurgentȱeventsȱtoȱARCȱ3ȱ
Œ Callȱall:ȱReportsȱnonȬurgentȱeventsȱtoȱallȱdefinedȱARC.ȱ
Œ 1stȱBackupȱ2nd:ȱReportsȱnonȬurgentȱeventsȱtoȱARCȱ1.ȱIfȱcommunicationȱisȱnotȱ
established,ȱcallsȱARCȱ2ȱ
Page 4-58
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Communication: ARC
Parameter
Default
Range
ReportȱCodesȱȱ
ȱ
ȱ
Enablesȱyouȱtoȱviewȱorȱprogramȱtheȱcodesȱtransmittedȱbyȱtheȱsystemȱtoȱreportȱeventsȱ(forȱ
example,ȱalarms,ȱfaults,ȱrestores,ȱsupervisoryȱtests,ȱandȱsoȱon)ȱtoȱtheȱalarmȱreceivingȱ
center.ȱTheȱcodesȱspecifiedȱforȱeachȱtypeȱofȱeventȱtransmissionȱareȱaȱfunctionȱofȱtheȱCentralȱ
Stationȇsȱownȱpolicies.ȱBeforeȱprogrammingȱanyȱcodes,ȱitȱisȱimportantȱtoȱcheckȱtheȱCentralȱ
Stationȱprotocols.ȱReportingȱcodesȱareȱassignedȱbyȱdefault,ȱaccordingȱtoȱtheȱselectedȱ
communicationȱformatȱSIAȱorȱContactȱIDȱ
Assignsȱaȱspecifiedȱreportȱcodeȱforȱeachȱevent,ȱbasedȱonȱtheȱreportingȱformatȱtoȱtheȱalarmȱ
receivingȱcenter.ȱAnȱeventȱthatȱisȱnotȱassignedȱwithȱaȱreportȱcodeȱwillȱnotȱbeȱreportedȱtoȱ
theȱalarmȱreceivingȱcenter.ȱForȱlistȱofȱreportȱeventsȱreferȱtoȱAppendixȱA.ȱ
4.3 Configuration Software
TheȱConfigurationȱSoftwareȱmenuȱcontainsȱparametersȱthatȱenableȱtheȱconfigurationȱ
softwareȱtoȱestablishȱconnectionȱwithȱtheȱsystem.ȱ
Communication: Configuration software
Parameter
Default
Securityȱ
Range
ȱ
ȱ
Enablesȱyouȱtoȱsetȱparametersȱforȱremoteȱcommunicationȱbetweenȱtheȱtechnicianȱandȱtheȱ
systemȱusingȱtheȱConfigurationȱsoftwareȱ
AccessȱCodeȱ
5678ȱ
ȱ
EnablesȱyouȱtoȱdefineȱanȱAccessȱCodeȱthatȱisȱstoredȱinȱtheȱsystem.ȱ
RISCOȱGroupȱrecommendsȱusingȱaȱdifferentȱ4ȬdigitȱAccessȱCodeȱforȱeachȱ
installation.ȱ
Inȱorderȱtoȱenableȱcommunicationȱbetweenȱtheȱalarmȱcompanyȱandȱtheȱsystemȱ
theȱsameȱAccessȱCodeȱmustȱsubsequentlyȱbeȱenteredȱintoȱtheȱcorrespondingȱ
accountȱprofileȱcreatedȱforȱtheȱinstallationȱinȱtheȱconfigurationȱsoftwareȱ
Forȱsuccessfulȱcommunication,ȱtheȱAccessȱCodeȱalongȱwithȱtheȱIDȱcodeȱmustȱ
matchȱbetweenȱtheȱconfigurationȱsoftwareȱandȱtheȱsystem.ȱ
RemoteȱIDȱȱȱ
0001ȱ
DefinesȱanȱIDȱCodeȱthatȱservesȱasȱanȱextensionȱofȱtheȱAccessȱCode.ȱ
Inȱorderȱtoȱenableȱcommunicationȱbetweenȱtheȱalarmȱcompanyȱandȱtheȱ
Installation,ȱtheȱsameȱRemoteȱIDȱcodeȱmustȱbeȱenteredȱintoȱtheȱaccountȱprofileȱ
inȱtheȱconfigurationȱsoftware.ȱ
Forȱsuccessfulȱcommunication,ȱtheȱIDȱCodeȱalongȱwithȱtheȱAccessȱCodeȱmustȱ
matchȱbetweenȱtheȱUpload/DownloadȱsoftwareȱandȱtheȱMainȱPanel.ȱ
DealersȱoftenȱuseȱtheȱcustomerȇsȱARCȱAccountȱNumberȱforȱtheȱȱ
IDȱCode,ȱbutȱyouȱcanȱuseȱanyȱ4Ȭdigitȱcodeȱuniqueȱtoȱtheȱinstallationȱ
Page 4-59
AgilityȱEngineerȱManualȱ
ȱ
Communication: Configuration software
Parameter
Default
ARCȱLockȱ
Range
000000ȱ
ȱ
ARCȱLockȱisȱaȱsecurityȱfunctionȱusedȱinȱconjunctionȱwithȱtheȱconfigurationȱ
software.ȱItȱprovidesȱgreaterȱproprietaryȱsecurityȱwhenȱviewingȱARCȱ
parameters.ȱ
Theȱsameȱ6Ȭdigitȱcode,ȱwhichȱwillȱbeȱstoredȱinȱtheȱpanel,ȱmustȱbeȱenteredȱintoȱ
theȱcorrespondingȱaccountȱprofileȱcreatedȱforȱtheȱinstallationȱinȱtheȱ
Configurationȱsoftware.ȱȱ
IfȱthereȱisȱnoȱmatchȱbetweenȱtheȱARCȱLockȱCodeȱdefinedȱinȱtheȱMainȱPanelȱandȱ
theȱARCȱLockȱCodeȱdefinedȱinȱtheȱConfigurationȱsoftware,ȱtheȱEngineerȱwillȱnotȱ
haveȱpermissionȱtoȱchangeȱtheȱfollowingȱARCȱparametersȱfromȱtheȱ
Configurationȱsoftware:ȱȱ
ARCȱLock,ȱEngineerȱCode,ȱARCȱIPȱPort,ȱARCȱIPȱAddress,ȱARCȱPhone,ȱDefaultȱ
Enable,ȱARCȱAccount,ȱARCȱFormat,ȱARCȱChannel,ȱARCȱBackup,ȱARCȱEnable,ȱ
RemoteȱID,ȱAccessȱCode.ȱ
CallȱBackȱ
CallȱBackȱȱEnableȱ
ȱ
ȱ
YESȱ
ȱ
TheȱcallȱbackȱfeatureȱrequiresȱtheȱsystemȱtoȱcallȱbackȱtoȱaȱpreȬprogrammedȱ
telephoneȱnumberȱtoȱwhichȱtheȱalarmȱcompanyȇsȱconfigurationȱsoftwareȱ
computerȱisȱinstalled.ȱThisȱprovidesȱmoreȱsecurityȱforȱremoteȱoperationsȱusingȱ
theȱconfigurationȱsoftware.ȱȱ
YES:ȱCallȱbackȱisȱenabledȱ
NO:ȱCallȱbackȱisȱdisabledȱ
CallȱBackȱPhonesȱȱ
ȱ
ȱ
Defineȱ3ȱnumbersȱthatȱtheȱpanelȱcanȱcallȱtoȱperformȱConfigurationȱSoftwareȱ
communication.ȱIfȱnoȱnumbersȱhaveȱbeenȱdefined,ȱaȱcallȱbackȱcanȱbeȱperformedȱ
toȱanyȱphone.ȱTheȱengineerȱwillȱenterȱaȱphoneȱnumberȱwhenȱestablishingȱ
communicationȱtoȱtheȱpanel.ȱIfȱatȱleastȱoneȱnumberȱhasȱbeenȱdefined,ȱitȱwillȱbeȱ
theȱonlyȱnumberȱthatȱtheȱcallȱbackȱcanȱbeȱestablishedȱtoo.ȱȱ
WhenȱtheȱConfigurationȱSoftwareȱestablishesȱcommunicationȱtoȱtheȱpanel,ȱitȱ
sendsȱtheȱpanelȱitsȱcallingȱphoneȱnumber.ȱ(Thisȱnumberȱneedsȱtoȱbeȱdefinedȱasȱ
MyȱNumberȱunderȱtheȱGSMȱandȱPSTNȱCommunicationȱmenuȱinȱtheȱ
ConfigurationȱSoftware.)ȱ
Ifȱtheȱpanelȱidentifiesȱoneȱofȱtheȱnumbersȱasȱoneȱofȱtheȱnumbersȱpredefinedȱinȱ
theȱpanel,ȱtheȱcallȱwillȱhangȱupȱandȱtheȱpanelȱwillȱcallȱbackȱtoȱthatȱsameȱnumber.ȱȱ
Page 4-60
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Communication: Configuration software
Parameter
Default
ConfigurationȱSoftwareȱPortȱ(IPȱGateway)ȱ
Range
00000ȱ ȱ
TheȱIPȱandȱportȱaddressȱofȱtheȱconfigurationȇsȱsoftwareȱPC.ȱIfȱyouȱhaveȱaȱrouterȱ
connectedȱtoȱtheȱPCȱofȱtheȱconfigurationȱsoftwareȱthenȱyouȱshouldȱenterȱtheȱIPȱofȱtheȱ
router.ȱ
Thisȱdefinitionȱwillȱbeȱusedȱwhenȱthereȱisȱaȱrequestȱtoȱcreateȱaȱremoteȱconnectionȱfromȱ
theȱpanelȱtoȱtheȱconfigurationȱsoftware.ȱTheȱconnectionȱcanȱbeȱdoneȱoverȱIPȱorȱGPRS.ȱ
Note:ȱInȱtheȱconfigurationȱsoftware,ȱunderȱCommunicationÆȱConfigurationÆGPRSȱyouȱshouldȱenterȱtheȱ
IPȱaddressȱofȱtheȱPCȱthatȱtheȱsoftwareȱisȱinstalledȱin.ȱ
4.4 Follow-Me
Inȱadditionȱtoȱreportingȱtoȱtheȱalarmȱreceivingȱcenter,ȱtheȱAgilityȱhasȱaȱFollowȬMeȱfeatureȱ
whichȱenablesȱreportingȱaȱsystemȱeventsȱtoȱaȱpredefinedȱfollowȱmeȱdestinationsȱusingȱaȱ
voiceȱmessage,ȱSMSȱmessageȱorȱEmail.ȱȱUpȱtoȱ16ȱFollowȱMeȱdestinationsȱcanȱbeȱdefinedȱinȱ
theȱsystem.ȱ
Parametersȱ
Communication: Follow-Me
Parameter
Default
Labelȱ(viaȱtheȱConfigurationȱSoftware)ȱ
Range
ȱ
ȱ
ȱ
ȱ
Aȱlabelȱidentifyingȱtheȱfollowȱmeȱdestinationȱ
Typeȱ
Definesȱtheȱtypeȱofȱreportingȱeventsȱtoȱaȱfollowȱmeȱdestination:ȱ
Œ Voice:ȱReportȱtoȱfollowȱmeȱwillȱbeȱdoneȱbyȱvoiceȱmessageȱthoroughȱtheȱ
PSTNȱorȱGSMȱnetwork.ȱ(SeeȱChannelÆȱForȱVoiceȱMessagingȱbelow).ȱTypeȱinȱ
theȱtelephoneȱnumberȱincludingȱareaȱcodeȱorȱspecialȱlettersȱforȱFollowȱMeȱ
definedȱasȱSMSȱorȱVoice.ȱ
Œ SMS:ȱReportȱtoȱfollowȱmeȱwillȱbeȱdoneȱbyȱSMS.ȱEachȱeventȱmessageȱcontainsȱ
informationȱincludingȱtheȱsystemȱlabel.ȱEventȱtypeȱandȱtime.ȱTypeȱinȱtheȱ
telephoneȱnumberȱincludingȱareaȱcodeȱorȱspecialȱlettersȱforȱFollowȱMeȱ
definedȱasȱSMSȱorȱVoice.ȱ
Œ EȬmail:ȱReportȱtoȱfollowȱmeȱwillȱbeȱdoneȱbyȱeȬmailȱthoroughȱIPȱorȱGPRS.ȱ
EachȱeȬmailȱcontainsȱinformationȱincludingȱtheȱsystemȱlabel.ȱEventȱtypeȱandȱ
time.ȱ(SeeȱChannelÆȱForȱEȬmailȱreportȱbelow)TypeȱinȱtheȱeȬmailȱaddressȱforȱ
followȱmeȱdestinationȱdefinedȱasȱeȬmailȱtype.ȱ
Page 4-61
AgilityȱEngineerȱManualȱ
ȱ
Communication: Follow-Me
Parameter
Default
Channelȱ
ȱ
Range
ȱ
ReportingȱeventsȱbyȱVoiceȱorȱEmailȱcanȱbeȱestablishedȱthroughȱdifferentȱchannels.ȱTheȱ
optionalȱchannelsȱdependȱonȱtheȱhardwareȱinstalledȱinȱtheȱsystem.ȱSelectȱtheȱrequiredȱ
channelȱasȱfollows:ȱ
ForȱVoiceȱMessaging:ȱ
PSTN/GSM:ȱȱTheȱsystemȱchecksȱforȱtheȱavailabilityȱofȱtheȱPSTNȱline.ȱDuringȱregularȱ
operationȱmodeȱvoiceȱmessagingȱisȱcarriedȱoutȱusingȱtheȱPSTNȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱ
theȱPSTNȱline,ȱtheȱlineȱisȱroutedȱtoȱtheȱGSMȱline.ȱ
GSM/PSTN:ȱTheȱpanelȱchecksȱforȱtheȱavailabilityȱofȱtheȱGSMȱline.ȱDuringȱregularȱ
operationȱmodeȱvoiceȱmessagingȱisȱcarriedȱoutȱusingȱtheȱGSMȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱ
theȱGSMȱline,ȱtheȱlineȱisȱroutedȱtoȱtheȱPSTNȱline.ȱ
PSTNȱOnly:ȱTheȱoutgoingȱcallsȱareȱexecutedȱthroughȱtheȱPSTNȱaudioȱchannelȱonly.ȱUseȱ
thisȱoptionȱforȱinstallationsȱwhereȱnoȱGSMȱlineȱisȱavailable.ȱ
GSMȱOnly:ȱTheȱoutgoingȱcallsȱareȱexecutedȱthroughȱtheȱGSMȱaudioȱchannelȱonly.ȱUseȱthisȱ
optionȱforȱinstallationsȱwhereȱnoȱPSTNȱlineȱisȱavailable.ȱ
ForȱEȬmailȱreport:ȱ
IP/GPRS:ȱȱTheȱsystemȱchecksȱforȱtheȱavailabilityȱofȱtheȱIPȱnetwork.ȱDuringȱregularȱ
operationȱemailsȱwillȱbeȱsentȱusingȱtheȱIPȱnetworkȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱtheȱIPȱ
network,ȱtheȱemailȱisȱroutedȱtoȱtheȱGPRSȱnetwork.ȱ
GPRS/IP:ȱȱTheȱsystemȱchecksȱforȱtheȱavailabilityȱofȱtheȱGPRSȱnetwork.ȱDuringȱregularȱ
operationȱmodeȱemailsȱwillȱbeȱsentȱusingȱtheȱGPRS.ȱInȱtheȱcaseȱofȱfaultȱtheȱemailȱisȱroutedȱ
toȱtheȱIPȱnetwork.ȱ
IPȱOnly:ȱTheȱreportȱisȱexecutedȱthroughȱtheȱIPȱnetworkȱonly.ȱ
GPRSȱOnly:ȱTheȱreportȱisȱexecutedȱthroughȱtheȱGPRSȱnetworkȱ
Eventsȱ
EachȱFollowȱMeȱdestinationȱcanȱbeȱassignedȱwithȱitsȱownȱsetȱofȱevents.ȱChooseȱtheȱeventsȱ
thatȱwillȱbeȱreportedȱtoȱeachȱFollowȱMeȱ
Eventȱ
Descriptionȱ
Defaultȱ
Alarmsȱ
Intruderȱ
Intruderȱalarmȱinȱtheȱsystemȱ
Yesȱ
Fireȱ
Fireȱalarmȱinȱtheȱsystemȱȱ
Yesȱ
Emergencyȱ
Emergencyȱalarmȱinȱtheȱsystemȱȱ
Yesȱ
Panicȱ(S.O.S)ȱ
Aȱpanicȱalarmȱinȱtheȱsystemȱ
Yesȱ
Tamperȱ
Anyȱtamperȱalarmȱinȱtheȱsystemȱ
Noȱ
DuressȱAlarmȱ
Duressȱalarmȱinȱtheȱsystemȱfromȱuserȱxxȱ
Yesȱ
NoȱMovementȱ
Noȱmovementȱreportȱindicationȱ
Noȱ
Page 4-62
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Communication: Follow-Me
Parameter
Default
Range
Set/Unsetȱ
Setȱ
Settingȱoperationȱhasȱbeenȱperformedȱinȱtheȱsystemȱ
Noȱ
Unsetȱ
Unsettingȱoperationȱhasȱbeenȱperformedȱinȱtheȱsystemȱ
Noȱ
ParentȱControlȱ
Systemȱset/unsetȱbyȱuser/remoteȱcontrolȱdefinedȱwithȱ
theȱParentȱcontrolȱfeatureȱ
Noȱ
Afterȱ5ȱunsuccessfulȱattemptsȱofȱenteringȱanȱincorrectȱ
code.ȱȱ
Noȱ
Faultsȱ
FalseȱCodeȱ
MainȱLowȱBatteryȱ LowȱbatteryȱindicationȱfromȱtheȱAgilityȱmainȱpanelȱ
(belowȱ6V)ȱ
Noȱ
WirelessȱLowȱ
Batteryȱ
Lowȱbatteryȱindicationȱfromȱanyȱwirelessȱdeviceȱinȱtheȱ
systemȱ
Noȱ
WLȱJammingȱ
Jammingȱindicationȱinȱtheȱsystemȱ
Noȱ
WLȱLostȱ
Wirelessȱdeviceȱlost.ȱWhenȱnoȱsupervisionȱsignalȱisȱ
receivedȱfromȱaȱwirelessȱdeviceȱ
Noȱ
ACȱOffȱ
InterruptionȱinȱtheȱsourceȱofȱtheȱmainȱACȱpower.ȱThisȱ
activationȱwillȱfollowȱtheȱdelayȱtimeȱpredefinedȱinȱtheȱ
ACȱLossȱDelayȱtimerȱ
Noȱ
PSTNȱFaultȱ
PSTNȱlostȱevent.ȱIfȱPSTNȱLossȱDelayȱtimeȱperiodȱisȱ
defined,ȱtheȱmessageȱwillȱbeȱsentȱafterȱtheȱdelayȱtimeȱ
Noȱ
IPȱNetworkȱ
CommunicationȱfaultȱwithȱtheȱIPȱnetwork.ȱ
Noȱ
GSMȱFaultȱ
GeneralȱGSMȱfaultȱ(SIMȱcardȱfault,ȱNetworkȱ
availability,ȱNetworkȱQuality,ȱPINȱcodeȱerror,ȱModuleȱ
communication,ȱGPRSȱpassword,ȱGPRSȱIPȱfault,ȱGPRSȱ
Connection,ȱPUKȱcodeȱfaultȱ
Noȱ
SIMȱFaultȱ
AnyȱfaultȱwithȱtheȱSIMȱcardȱ
Noȱ
SIMȱExpireȱ
ReportȱtoȱFollowȱMeȱwillȱbeȱestablishedȱ30ȱdaysȱbeforeȱ
theȱSIMȱExpirationȱTimeȱdefinedȱforȱaȱprepaidȱSIMȱcard.
Noȱ
SIMȱCreditȱ
AnȱautomaticȱSMSȱcreditȱmessageȱ(orȱanyȱotherȱ
message)ȱreceivedȱfromȱtheȱprovider’sȱnumberȱ
predefinedȱinȱSMSȱReceiveȱPhoneȱwillȱbeȱtransferredȱtoȱ
theȱFollowȱMeȱnumberȱ
Noȱ
GSMȱȱ
Page 4-63
AgilityȱEngineerȱManualȱ
ȱ
Communication: Follow-Me
Parameter
Default
Range
Environmentalȱȱ
GasȱAlertȱ
Gasȱ(naturalȱgas)ȱalertȱfromȱaȱzoneȱdefinedȱaȱGasȱ
detectorȱ
Noȱ
FloodȱAlertȱ
Floodȱalertȱfromȱaȱzoneȱdefinedȱasȱfloodȱtypeȱ
Noȱ
COȱAlertȱ
COȱ(CarbonȱMonoxide)ȱalertȱfromȱaȱzoneȱdefinedȱaȱCOȱ
detectorȱ
Noȱ
Highȱ
Temperatureȱ
HighȱTemperatureȱalertȱfromȱaȱzoneȱdefinedȱaȱ
Temperatureȱdetectorȱ
Noȱ
LowȱTemperatureȱ LowȱTemperatureȱalertȱfromȱaȱzoneȱdefinedȱaȱ
Temperatureȱdetectorȱ
Noȱ
Technicalȱ
Noȱ
AlertȱfromȱtheȱzoneȱdefinedȱasȱTechnicalȱ
Miscellaneousȱȱ
ZoneȱOmitȱ
Zoneȱhasȱbeenȱomittedȱȱ
Noȱ
Periodicȱtestȱ
FollowȱMeȱtestȱmessageȱwillȱbeȱestablishedȱfollowingȱ
theȱtimeȱdefinedȱinȱtheȱPeriodicȱTestȱparameterȱunderȱ
theȱARCȱparametersȱ
Noȱ
Remoteȱ
programmingȱ
Systemȱisȱinȱremoteȱinstallationȱmodeȱ
Noȱ
RestoreȱEvents:ȱ
Alarmsȱ
ȱ
IntruderȱAlarmȱ
Intruderȱalarmȱinȱtheȱsystemȱrestoredȱ
Yesȱ
Tamperȱ
Tamperȱalarmȱinȱtheȱsystemȱrestoredȱ
Noȱ
Faultsȱ
ȱ
MainȱLowȱBatteryȱ LowȱbatteryȱindicationȱfromȱtheȱAgilityȱmainȱpanelȱ
restoredȱ
Noȱ
WLȱLowȱBatteryȱ
Lowȱbatteryȱindicationȱfromȱanyȱwirelessȱdeviceȱinȱtheȱ
systemȱrestoredȱ
Noȱ
Jammingȱ
Jammingȱindicationȱinȱtheȱsystemȱrestoredȱ
Noȱ
WLȱLostȱ
Wirelessȱdeviceȱlostȱrestoredȱ
Noȱ
ACȱOffȱ
InterruptionȱinȱtheȱsourceȱofȱtheȱmainȱACȱpowerȱ
restoredȱ
Noȱ
PSTNȱFaultȱ
PSTNȱlostȱeventȱrestoredȱ
Noȱ
IPȱNetworkȱ
CommunicationȱfaultȱinȱtheȱIPȱrestoredȱ
Noȱ
GSMȱFaultȱ
GeneralȱGSMȱfaultȱrestoredȱ
Noȱ
Page 4-64
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Communication: Follow-Me
Parameter
Default
Environmentalȱ
ȱ
GasȱAlertȱ
GasȱAlertȱrestoredȱ
Range
Noȱ
FloodȱAlertȱ
FloodȱAlertȱrestoredȱ
Noȱ
COȱAlertȱ
COȱAlertȱrestoredȱ
Noȱ
Highȱ
Temperatureȱ
HighȱTemperatureȱAlertȱrestoredȱ
Noȱ
LowȱTemperatureȱ LowȱTemperatureȱAlertȱrestoredȱ
Noȱ
Technicalȱ
Noȱ
TechnicalȱAlertȱrestoredȱ
RemoteȱControlȱ
ȱ
RemoteȱListenȱ
ȱ
Noȱ
ȱ
Enablesȱtheȱuserȱofȱtheȱfollowȱmeȱphoneȱtoȱperformȱremoteȱlistenȱandȱtalkȱ
operationȱwithȱtheȱpremises.ȱ
Remoteȱprogramȱ
Noȱ
ȱ
EnablesȱtheȱuserȱofȱtheȱfollowȱmeȱphoneȱtoȱenterȱtheȱRemoteȱOperationȱmenuȱ
andȱperformȱallȱavailableȱprogrammingȱoptions.ȱForȱmoreȱdetailsȱseeȱtheȱUserȱ
manual.ȱ
Partitionȱ
ȱ
ȱ
Assignȱtheȱpartitionsȱfromȱwhichȱeventsȱwillȱbeȱreportedȱtoȱtheȱfollowȱmeȱnumber.ȱ
Controlsȱ
ȱ
ȱ
AllowsȱtoȱprogramȱcontrolȱrelatedȱtoȱoperationȱwithȱtheȱFollowȱMeȱ
UnsetȱStopȱFollowȱMeȱ
Noȱ
ȱ
YES:ȱTheȱFollowȬMeȱcallsȱwillȱstopȱwhenȱtheȱpartitionsȱareȱunsetȱbyȱaȱuserȱcodeȱ
NO:ȱTheȱFollowȬMeȱcallsȱwillȱcontinueȱtoȱbeȱmadeȱwhenȱtheȱpartitionsȱareȱunsetȱ
byȱaȱuserȱcodeȱ
Parametersȱ
ȱ
ȱ
AllowsȱtoȱprogramȱparametersȱrelatedȱtoȱoperationȱwithȱtheȱFollowȱMeȱ
FollowȱMeȱRetriesȱ
03ȱ
01Ȭ15ȱ
TheȱnumberȱofȱtimesȱtheȱFollowȱMeȱphoneȱnumberȱisȱredialedȱ
VoiceȱMessageȱRecurrenceȱ
01ȱ
01Ȭ05ȱ
Thisȱnumberȱofȱtimesȱaȱvoiceȱmessageȱrepeatsȱitselfȱwhenȱestablishingȱaȱcallȱtoȱaȱ
FollowȱMeȱnumber.ȱ
Page 4-65
AgilityȱEngineerȱManualȱ
ȱ
Communication: Follow-Me
Parameter
Default
FollowȱMeȱPeriodicȱTestȱ
ȱ
Range
ȱ
TheȱPeriodicȱTestȱenablesȱyouȱtoȱsetȱtheȱtimeȱperiodȱthatȱtheȱsystemȱwillȱ
automaticallyȱestablishȱcommunicationȱtoȱaȱFollowȱMeȱdestinationȱdefinedȱwithȱ
theȱPeriodicȱTestȱevent.ȱȱ
Page 4-66
AgilityȱEngineerȱManualȱ
ȱ
ȱ
5. Programming: Audio Messages Menu
Thisȱmenuȱisȱusedȱtoȱdefineȱvoiceȱmessageȱparameters.ȱTheȱAudioȱMessagesȱmenuȱisȱdividedȱ
intoȱtheȱfollowingȱsubȱmenus:ȱ
1.ȱAssignȱMessageȱ
2.ȱLocalȱMessageȱ
5.1 Assign Message
Theȱengineerȱcanȱassignȱaȱvoiceȱmessageȱtoȱaȱzone,ȱpartition,ȱoutputȱorȱmacro.ȱWhenȱanȱ
eventȱoccursȱthisȱvoiceȱmessageȱwillȱbeȱheardȱaccordingly.ȱȱ
Eachȱmessageȱcanȱbeȱcomprisedȱofȱupȱtoȱ4ȱwords.ȱEachȱwordȱhasȱbeenȱpreȬrecordedȱandȱ
assignedȱaȱnumber.ȱWhenȱcomprisingȱaȱmessageȱtheȱengineerȱwillȱenterȱtheȱnumberȱofȱeachȱ
wordȱintoȱtheȱmessageȱsequence.ȱTheȱsystemȱrecognizesȱtheȱnumbersȱandȱsoundsȱtheȱwordsȱ
assignedȱtoȱthoseȱnumbers.ȱ(SeeȱDescriptorȱDirectoryȱbelow)ȱForȱexample:ȱForȱtheȱsystemȱtoȱ
soundȱ“TopȱFloorȱGuestȱBedroom”,ȱtheȱengineerȱmustȱenterȱtheȱfollowingȱsequence:ȱ119ȱȱ050ȱȱ
061ȱȱ019.ȱ
TheȱtableȱinȱAppendixȱC:ȱLibraryȱVoiceȱMessagesȱdisplaysȱtheȱdirectoryȱofȱtheȱpreȬrecordedȱ
programmingȱdescriptors,ȱeachȱisȱidentifiedȱbyȱaȱ3ȱdigitȱnumber.ȱȱ
Note:ȱTheȱfirstȱfiveȱdescriptorsȱallowȱforȱcustomizedȱwordsȱspecificȱforȱtheȱclient’sȱneeds.ȱTheȱcustomizedȱ
wordsȱcanȱbeȱrecordedȱviaȱtheȱtelephone.ȱEachȱrecordingȱisȱ2ȱsecondsȱlong.ȱ
ȱToȱassignȱaȱmessageȱfollowȱthisȱprocedure:ȱ
1.ȱGoȱtoȱProgrammingȱÆȱAudioȱMessagesȱÆȱAssignȱMessage.ȱ
2.ȱSelectȱtheȱrelevantȱdeviceȱandȱgoȱtoȱDefine.ȱ
3.ȱEnterȱtheȱrelevantȱdescriptorȱnumbersȱ(seeȱAppendixȱ3:ȱLibraryȱVoiceȱMessages)ȱandȱȱȱ
.ȱ
ȱȱȱȱpressȱ
4.ȱGoȱtoȱPlayȱtoȱhearȱtheȱmessage.ȱ
5.2 Local Message
Uponȱeventȱoccurrence,ȱtheȱsystemȱcanȱannounceȱtheȱsecurityȱsituationȱtoȱoccupantsȱofȱtheȱ
premisesȱbyȱsoundingȱaȱlocalȱannouncementȱmessage.ȱThisȱannouncementȱmessageȱcanȱbeȱ
enabledȱorȱdisabled,ȱperȱevent.ȱEnableȱorȱdisableȱeachȱmessageȱannouncementȱaccordingȱtoȱ
yourȱcustomerȱrequest.ȱ
Audio Messages: Local Messages
Parameter
Description
Intruderȱalarmȱ
Intruderȱalarmȱ
Default
Fireȱalarmȱ
Fireȱalarmȱ
Yesȱ
Emergencyȱ
Emergencyȱ(medical)ȱalarmȱ
Yesȱ
Yesȱ
Page 4-67
AgilityȱEngineerȱManualȱ
ȱ
Audio Messages: Local Messages
Parameter
Description
Panicȱalarmȱ
Panicȱalarmȱ
Default
Yesȱ
Tamperȱalarmȱ
Tamperȱalarmȱ
Yesȱ
Environmentalȱ
alertȱ
Flood,ȱGas,ȱCOȱorȱTemperatureȱalertȱ
Yesȱ
FullȱSetȱ
System/PartitionȱsetȱinȱFullȱSetȱ
Yesȱ
PartȱSetȱ
System/PartitionȱsetȱinȱPartȱSetȱ
Yesȱ
Unsetȱ
System/Partitionȱunsetȱ
Yesȱ
AudibleȱStatusȱ
Statusȱheardȱwhenȱpressingȱtheȱstatusȱbuttonȱonȱtheȱ
keypad/remoteȱcontrolȱ
Yesȱ
Entryȱ/ȱExitȱ
Systemȱinȱexitȱorȱentryȱdelayȱ
Yesȱ
Autoȱsetȱ
Systemȱinȱautoȱsetȱprocessȱȱ
Yesȱ
OutputȱOn/Offȱ
Outputȱactivatedȱorȱdeactivatedȱ(Outputsȱdefinedȱasȱ
FollowȱCode)ȱ
Noȱ
Walkȱtestȱ
Walkȱtest.ȱTheȱAgilityȱwillȱsoundȱtheȱzoneȱnumberȱandȱ
descriptionȱ
Yesȱ
NoȱMovementȱ
Noȱmovementȱmessageȱ
Yesȱ
Miscellaneousȱ
ChimeȱstatusȱandȱMacroȱmessagesȱ
Yesȱ
Page 4-68
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Testing menu
Theȱfollowingȱmenuȱisȱusedȱtoȱperformȱtestsȱonȱtheȱsystem.ȱNoteȱthatȱeachȱtestȱrefersȱtoȱtheȱ
lastȱtimeȱtheȱdeviceȱwasȱactivated.ȱTestsȱcanȱbeȱperformedȱonȱtheȱfollowingȱelements:ȱ
1.ȱMainȱUnitȱ
2.ȱZoneȱ
3.ȱRemoteȱControlȱ(Keyfob)ȱ
4.ȱKeypadȱ
5.ȱSounderȱ
6.ȱGSMȱ
7.ȱIPȱUnitȱ
8.ȱPOȱUnitȱ
1. Main Unit
Main Unit
Parameter
NoiseȱLevelȱ
ȱ
ȱ
Thisȱfeatureȱestablishesȱtheȱthresholdȱnoiseȱlevelȱofȱtheȱmainȱunitȱreceiver.ȱTheȱthresholdȱ
noiseȱlevelȱcanȱbeȱestablishedȱautomaticallyȱorȱmanuallyȱ(whenȱusingȱaȱkeypad).ȱ
Toȱestablishȱtheȱmainȱunitȱreceiverȇsȱnoiseȱlevel:ȱ
Automatic:ȱForȱautomaticȱcalibrationȱselectȱ[2]ȱCalibrate.ȱAfterȱtheȱcalibrationȱ
processȱisȱaccomplished,ȱtheȱnewȱnoiseȱthresholdȱlevelȱisȱdisplayed.ȱ
Manual:ȱForȱmanualȱcalibrationȱselectȱ[1]ȱView/Edit.ȱTheȱvalueȱdisplayedȱisȱtheȱlastȱ
measuredȱvalue.ȱSetȱaȱnewȱthresholdȱlevelȱandȱpressȱ
Sounderȱ
ȱtoȱconfirm.ȱ
ȱ
ȱ
ȱ
ȱ
Activatesȱtheȱmainȱunitȱsounder.ȱ
Speakerȱ
Soundsȱtheȱlocalȱtestȱmessage:ȱ“Testȱmessage”.ȱSelectȱStartȱtoȱactivateȱtheȱfeature.ȱSelectȱ
Stopȱtoȱendȱtheȱtest.ȱȱȱȱ
Batteryȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Displaysȱtheȱbatteryȱvoltageȱofȱtheȱmainȱunit.ȱ
Versionȱ
Displaysȱtheȱmainȱunitȇsȱsoftwareȱversion.ȱ
SerialȱNumberȱ
Displaysȱtheȱmainȱunitȇsȱserialȱnumber.ȱ
Page 4-69
AgilityȱEngineerȱManualȱ
ȱ
2. Zone
Zone
Parameter
Default
CommȱTestȱ
Range
ȱ
0Ȭ99ȱ
Displaysȱtheȱresultsȱofȱtheȱlastȱmeasurementȱperformedȱafterȱtheȱlastȱtransmissionȱ(lastȱ
detectionȱorȱlastȱsupervisionȱsignal).ȱToȱreceiveȱanȱupdatedȱsignalȱstrength,ȱactivateȱtheȱ
detectorȱpriorȱtoȱperformingȱtheȱcommunicationȱtest.ȱ
Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ
thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ
BatteryȱTestȱ
ȱ
ȱ
Displaysȱtheȱresultsȱofȱtheȱlastȱbatteryȱtestȱperformedȱafterȱtheȱlastȱtransmission.ȱOKȱ
messageȱisȱdisplayedȱforȱaȱsuccessfulȱtest.ȱForȱanȱupdatedȱvalueȱactivateȱtheȱdevice.ȱ
WalkȱTestȱ
Usedȱtoȱeasilyȱtestȱandȱevaluateȱtheȱoperationȱofȱselectedȱzonesȱinȱyourȱsystem.ȱItȱisȱ
recommendedȱtoȱperformȱwalkȱtestȱafterȱinstallingȱallȱwirlessȱdevicesȱandȱalsoȱpriorȱtoȱ
performingȱTestingȱoperation.ȱ
TheȱkeypadȱLCDȱdisplaysȱtheȱfollowingȱinformation:ȱȱ
ȱ
Zoneȱnumber;ȱTRIP:ȱSuccessfulȱdetection;ȱTMP:ȱTamperȱdetectionȱandȱTrbl:ȱLowȱbatteryȱ
Versionȱ
Thisȱmenuȱdisplaysȱsoftwareȱversionȱofȱtheȱselectedȱ2Ȭwayȱdetector.ȱȱȱ
3. Remote Control (Keyfob)
Remote Control
Parameter
Default
CommȱTestȱ
Range
ȱ
ȱ
Displaysȱtheȱresultsȱofȱtheȱlastȱmeasurementȱperformedȱafterȱtheȱlastȱtransmission.ȱToȱ
receiveȱanȱupdatedȱsignalȱstrength,ȱactivateȱtheȱremoteȱcontrolȱpriorȱtoȱperformingȱtheȱ
communicationȱtest.ȱ
Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ
thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ
BatteryȱTestȱ
ȱ
ȱ
Displaysȱtheȱresultsȱofȱtheȱlastȱbatteryȱtestȱperformedȱafterȱtheȱlastȱtransmission.ȱOKȱ
messageȱisȱdisplayedȱforȱaȱsuccessfulȱtest.ȱForȱanȱupdatedȱvalueȱactivateȱtheȱdevice.ȱ
Page 4-70
AgilityȱEngineerȱManualȱ
ȱ
ȱ
4. Keypad
Keypad
Parameter
Default
CommȱTestȱ
Range
ȱ
ȱ
Displaysȱtheȱresultsȱofȱtheȱlastȱmeasurementȱperformedȱafterȱtheȱlastȱtransmission.ȱToȱ
receiveȱupdatedȱsignalȱstrength,ȱactivateȱtheȱkeypadȱpriorȱtoȱperformingȱtheȱ
communicationȱtest.ȱ
Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ
thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ
BatteryȱTestȱ
ȱ
Displaysȱtheȱresultsȱofȱtheȱlastȱbatteryȱtestȱperformedȱafterȱtheȱlastȱ ȱ
transmission.ȱOKȱmessageȱisȱdisplayedȱforȱaȱsuccessfulȱtest.ȱForȱanȱ
updatedȱvalueȱactivateȱtheȱdevice.ȱ
Versionȱ
ȱ
ȱ
ȱ
ȱ
Thisȱmenuȱdisplaysȱinformationȱregardingȱtheȱkeypadȇsȱversion.ȱ
5. Sounder
Sounder
Parameter
Default
CommȱTestȱ
Range
ȱ
ȱ
TheȱsounderȱcommunicationȱtestȱperformsȱaȱcommunicationȱtestȱbetweenȱtheȱAgilityȱ
andȱtheȱselectedȱsounder.ȱTheȱvalueȱdisplayedȱindicatesȱtheȱsounderȇsȱsignalȱstrengthȱasȱ
receivedȱbyȱtheȱAgility.ȱȱȱ
Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ
thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ
BatteryȱTestȱ
ȱ
ȱ
Speakerȱbatteriesȱvoltage:ȱTestsȱtheȱselectedȱsounder’sȱspeakerȱbatteriesȱvoltage.ȱȱȱ
Radioȱ(Transceiver)ȱbatteriesȱvoltage:ȱTestsȱtheȱselectedȱsounder’sȱradioȇsȱbatteriesȱ
voltage.ȱȱȱ
SoundȱTestȱ
ȱ
Activatesȱsquawkȱsoundȱinȱtheȱselectedȱsounder.ȱ
Page 4-71
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Sounder
Parameter
Default
NoiseȱLevelȱ
Range
ȱ
ȱ
Thisȱfeatureȱestablishesȱtheȱthresholdȱnoiseȱlevelȱofȱtheȱwirelessȱsounderȱreceiver.ȱTheȱ
thresholdȱnoiseȱlevelȱcanȱbeȱestablishedȱautomaticallyȱorȱmanuallyȱ(whenȱusingȱaȱ
keypad).ȱ
Toȱestablishȱaȱsounderȱreceiverȇsȱnoiseȱlevel:ȱ
1.ȱȱSelectȱtheȱsounderȱforȱwhichȱyouȱwantȱtoȱcalibrateȱitsȱreceiver.ȱ
2.ȱForȱautomaticȱcalibrationȱselectȱ[2]ȱCalibrate.ȱAfterȱtheȱcalibrationȱprocessȱisȱȱ
ȱȱȱȱaccomplished,ȱtheȱnewȱnoiseȱthresholdȱlevelȱisȱdisplayed.ȱ
3.ȱForȱmanualȱcalibrationȱselectȱ[1]ȱView/Edit.ȱTheȱvalueȱdisplayedȱisȱtheȱlastȱȱ
ȱȱȱȱȱmeasuredȱvalue.ȱSetȱaȱnewȱthresholdȱlevelȱandȱpressȱ
ȱtoȱconfirm.ȱ
Versionȱ
ȱ
ȱ
Thisȱmenuȱdisplaysȱinformationȱregardingȱtheȱsounderȇsȱversion.ȱ
6. GSM
GSM
Parameter
Default
Signalȱ(RSSI)ȱ
Range
ȱ
ȱ
DisplaysȱtheȱsignalȱlevelȱmeasuredȱbyȱtheȱGSMȱmodule.ȱ(0=Noȱsignal,ȱ5=ȱVeryȱhighȱ
signal)ȱ
Versionȱ
ȱ
ȱ
ȱ
ȱ
DisplaysȱinformationȱregardingȱtheȱGSMȱcardȱversion.ȱ
IMEIȱ
ViewȱtheȱIMEIȱnumberȱofȱtheȱGSMȱmodule.ȱThisȱnumberȱisȱusedȱforȱidentificationȱofȱtheȱ
AgilityȱatȱtheȱRISCOȱIPȱreceiverȱwhenȱusingȱGSMȱorȱGPRSȱcommunication.ȱ
7. IP Unit
IP Unit
Parameter
Default
IPȱAddressȱ
Range
ȱ
ȱ
ȱ
ȱ
ViewȱtheȱIPȱaddressȱofȱtheȱAgilityȱ
Versionȱ
ViewȱtheȱversionȱonȱtheȱIPȱcardȱ
Page 4-72
AgilityȱEngineerȱManualȱ
ȱ
ȱ
IP Unit
Parameter
Default
MACȱAddressȱ
Range
ȱ
ȱ
ViewȱtheȱMACȱaddressȱofȱtheȱIPȱcard.ȱThisȱnumberȱisȱusedȱforȱidentificationȱofȱtheȱ
AgilityȱatȱtheȱRISCOȱIPȱreceiverȱwhenȱusingȱIPȱcommunication.ȱ
8. PO Unit
PO Unit
Parameter
Default
CommȱTestȱ
Range
ȱ
ȱ
Displaysȱtheȱresultsȱofȱtheȱlastȱmeasurementȱperformedȱafterȱtheȱlastȱtransmission.ȱToȱ
receiveȱanȱupdatedȱsignalȱstrength,ȱactivateȱtheȱPOȱunitȱpriorȱtoȱperformingȱtheȱ
communicationȱtest.ȱ
Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ
thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ
BatteryȱTestȱ
ȱ
ȱ
Displaysȱtheȱresultsȱofȱtheȱlastȱbatteryȱtestȱperformedȱafterȱtheȱlastȱtransmission.ȱOKȱ
messageȱisȱdisplayedȱforȱaȱsuccessfulȱtest.ȱForȱanȱupdatedȱvalueȱactivateȱtheȱdevice.ȱ
Versionȱ
ȱ
ThisȱmenuȱdisplaysȱinformationȱregardingȱtheȱPOȱunitȇsȱversion.ȱ
ȱ
Page 4-73
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Activities Menu
TheȱengineerȱcanȱperformȱspecialȱactivitiesȱonȱtheȱsystemȱviaȱtheȱActivitiesȱmenu.ȱSomeȱofȱ
theseȱactivitiesȱcanȱalsoȱbeȱperformedȱbyȱtheȱuser.ȱ
Activities
Parameter
Default
Range
MainȱBuzzerȱOn/Offȱ
ȱ
ȱ
Usedȱtoȱactivate/deactivateȱtheȱmainȱunitȱbuzzer.ȱ
KPȱSleepȱTimeȱ
10ȱsecondsȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ00Ȭ60ȱsecondsȱ
UsedȱtoȱsetȱtheȱkeypadȇsȱSleepȱmodeȱtime.ȱ(TheȱLCDȱdisplayȱisȱturnedȱoff.)ȱ
SounderȱTMPȱMuteȱ
ȱ
ȱ
Usedȱtoȱsilenceȱanȱalarmȱinitiatedȱbyȱaȱtamperȱfromȱaȱsounderȱforȱ20ȱminutes.ȱUseȱthisȱ
optionȱforȱexample,ȱwhenȱreplacingȱtheȱsounderȱbattery.ȱ
AvoidȱReportȱProgrammingȱ
ȱ
ȱ
Someȱprotocolsȱhaveȱaȱreportȱcodeȱtoȱtheȱalarmȱreceivingȱcenterȱforȱenteringȱandȱexitingȱ
theȱengineerȱprogramming.ȱToȱavoidȱtheȱenteringȱreportȱandȱsaveȱtime,ȱthisȱfunctionȱ
postponesȱtheȱreportȱforȱtwoȱminutesȱduringȱwhichȱtheȱengineerȱcanȱenterȱtheȱ
programmingȱmenuȱandȱnoȱreportȱwillȱbeȱmade.ȱ
OmitȱBoxȱTamperȱ
ȱ
ȱ
Providesȱabilityȱtoȱomitȱboxȱtamperȱcondition.ȱWhenȱactivatedȱandȱtamperȱconditionȱ
occurs,ȱthereȱwillȱbeȱnoȱalarm,ȱnoȱindicationȱtoȱtheȱARCȱandȱnoȱrecordȱinȱtheȱeventȱlog.ȱ
Note:ȱToȱenableȱOmitȱBoxȱTamper,ȱbothȱtheȱAllowȱOmitȱandȱ24ȱHourȱOmitȱparametersȱmustȱbeȱsetȱtoȱYESȱ
(referȱtoȱpageȱ4Ȭ5ȱandȱpageȱ4Ȭ8ȱforȱmoreȱinformation).ȱ
EngineerȱResetȱ
ȱ
ȱ
ȱ
ȱ
Useȱthisȱoptionȱtoȱresetȱanȱalarm.ȱ
ConfigurationȱSoftwareȱConnectȱ
Enablesȱtoȱestablishȱremoteȱcommunicationȱwithȱtheȱconfigurationȱsoftwareȱatȱaȱ
predefinedȱlocationȱthroughȱIPȱorȱGPRS.ȱ
Note:ȱTheȱlocationȱofȱtheȱconfigurationȱsoftwareȱshouldȱbeȱpredefinedȱunderȱ
CommunicationÆConfigurationȱSoftwareÆIPȱGatewayȱ
FirmwareȱUpdateȱ
ȱ
ȱ
Thisȱoptionȱactivatesȱaȱfirmwareȱupdateȱprocess.ȱTheȱupdateȱcanȱbeȱestablishedȱthroughȱ
IPȱorȱGPRS.ȱȱTheȱlocationȱofȱtheȱnewȱfirmwareȱshouldȱbeȱpredefinedȱunderȱEngineerȱ
ProgrammingÆȱSystemÆFirmwareȱUpdate.ȱ
Onceȱtheȱcommunicationȱmethodȱisȱselectedȱ(IPȱorȱGPRS)ȱaȱspecialȱmanufacturerȱ
passwordȱshouldȱbeȱentered.ȱPleaseȱreferȱtoȱyourȱlocalȱRISCOȱbranchȱforȱthisȱpassword.ȱ
Page 4-74
AgilityȱEngineerȱManualȱ
ȱ
ȱ
Follow Me Menu
Follow Me
Parameter
Defineȱ
UsedȱtoȱdefineȱFollowȱMeȱdestinationsȱphoneȱnumberȱorȱEȬmailȱaddressȱaccordingȱtoȱitsȱ
type:ȱVoiceȱmessage,ȱSMSȱorȱEȬmailȱ
TestȱFMȱ
UsedȱtoȱtestȱFollowȱMeȱreporting.ȱ
Clock Menu
Clock
Parameter
Default
Range
Timeȱ+ȱDateȱ
ȱ
ȱ
Allowsȱtheȱsettingȱofȱtheȱsystemȱtimeȱandȱdate.ȱThisȱdefinitionȱisȱrequiredȱforȱsettingȱtheȱ
schedulerȱprogrammingȱinȱtheȱsystem.ȱ
Schedulerȱ
ȱ
On/Offȱ
Enablesȱyouȱtoȱactivateȱorȱdeactivateȱpreprogrammedȱschedulesȱthatȱwereȱdefinedȱbyȱ
yourȱengineer.ȱUpȱtoȱ8ȱweeklyȱprogramsȱcanȱbeȱdefinedȱinȱtheȱsystemȱduringȱwhichȱtheȱ
systemȱautomaticallyȱsetsȱ/ȱunsetsȱorȱactivatesȱprogrammingȱoutputs.ȱ
Note:ȱTheȱdefinitionȱofȱtheȱschedulingȱprogramsȱisȱdoneȱfromȱtheȱconfigurationȱsoftware.ȱ
AutomaticȱClockȱ
ȱ
ȱ
UsedȱtoȱgetȱanȱautomaticȱtimeȱupdateȱthroughȱtheȱIPȱnetworkȱorȱGPRS.ȱ
Serverȱ
SelectȱtheȱInternetȱtimeȱprotocolȱNTPȱorȱDaytime.ȱ
Hostȱ
TheȱIPȱaddressȱorȱserverȱname.ȱ
Portȱ
Theȱserverȱport.ȱ
TimeȱZoneȱ(GMT/UTC)ȱ
Useȱtheȱ
ȱkeyȱtoȱaddȱanȱhourȱtoȱtheȱGMT/UTCȱtime.ȱUseȱtheȱ
subtractȱanȱhourȱfromȱtheȱGMT/UTCȱtime.ȱ
Page 4-75
ȱkeyȱtoȱ
AgilityȱEngineerȱManualȱ
ȱ
Event Log Menu
Allowsȱtheȱviewingȱofȱsignificantȱsystemȱeventsȱincludingȱdateȱandȱtime.ȱScrollȱtheȱlistȱ
usingȱtheȱarrowȱkeysȱtoȱviewȱtheȱeventsȱinȱtheȱsystem.ȱȱ
Macro Menu
Programming Macro Keys
AgilityȱenablesȱtheȱEngineerȱorȱGrandȱMasterȱtoȱrecordȱaȱseriesȱofȱcommandsȱandȱassignȱ
themȱtoȱaȱmacro.ȱWhenȱtheȱmacroȱisȱpressed,ȱtheȱrecordedȱcommandsȱareȱexecutedȱfromȱ
beginningȱtoȱend.ȱUpȱtoȱ3ȱmacrosȱcanȱbeȱprogrammedȱtoȱaȱsystemȱusingȱtheȱAgilityȱkeypadȱ
orȱtheȱAgilityȱConfigurationȱSoftware.ȱȱ
Beforeȱprogrammingȱaȱmacro,ȱitȱisȱrecommendedȱtoȱperformȱyourȱrequiredȱseriesȱofȱ
commands,ȱmakingȱaȱnoteȱofȱeveryȱkeyȱyouȱpressȱwhileȱdoingȱso.ȱ
Note:ȱMacrosȱcannotȱbeȱprogrammedȱtoȱperformȱdisarmingȱcommands.ȱ
Toȱprogramȱaȱmacro:ȱ
.ȱ
1.
InȱtheȱMacroȱmenuȱselectȱaȱmacroȱ(A,ȱBȱorȱC)ȱandȱpress
2.
Enterȱtheȱsequenceȱofȱcharactersȱaccordingȱtoȱtheȱfollowingȱtable:ȱ
Key
Represents
Usedȱtoȱenterȱnumericalȱcharactersȱ
ȱ
ȱ
Usedȱtoȱmoveȱtheȱcurserȱtoȱtheȱleftȱ
Usedȱtoȱmoveȱtheȱcurserȱtoȱtheȱrightȱ
ȱ
Pressȱ1ȱtwiceȱ
RepresentsȱtheȱÇȱcharacterȱ
Pressȱ3ȱtwiceȱ
RepresentsȱtheȱÈȱcharacterȱ
Pressȱ4ȱtwiceȱ
Representsȱtheȱ
ȱkeyȱ
Pressȱ6ȱtwiceȱ
Representsȱtheȱ
ȱkeyȱ
Pressȱ7ȱtwiceȱ
Representsȱtheȱ¾ȱcharacterȱ
Pressȱ9ȱtwiceȱ
Representsȱtheȱ#ȱcharacterȱ
ȱandȱ0ȱsimultaneouslyȱ
Deletesȱyourȱentryȱfromȱtheȱcursorȱpositionȱforwardȱ
Page 4-76
AgilityȱEngineerȱManualȱ
Key
ȱ
Represents
/
Useȱtoȱtoggleȱbetweenȱ
numericȱcharactersȱ
/
/Ç/È/#/¾ȱandȱallȱofȱtheȱ
Usedȱtoȱendȱtheȱsequenceȱandȱsaveȱitȱtoȱmemoryȱ
3.
Press
ȱtoȱsaveȱyourȱentry.ȱȱ
Theȱseriesȱofȱcharactersȱisȱsavedȱandȱassignedȱtoȱtheȱselectedȱmacro.ȱ
ȱ
Forȱexample:ȱ
Toȱsetȱpartitionȱ1ȱwithȱtheȱcodeȱ1234,ȱenterȱtheȱfollowingȱsequence:ȱ
ȱȱ1ȱ
ȱ1ȱ2ȱ3ȱ4ȱ
Activating a Macro
Pressȱ7/8/9ȱonȱtheȱkeypadȱforȱ2ȱsecondsȱtoȱactivateȱtheȱmacroȱA/B/Cȱrespectively.ȱAȱ
confirmationȱmessageȱwillȱbeȱheard:ȱȱ
Ȉ[MacroȱX]ȱactivatedȈ.ȱ
ȱ
ȱ
ȱ
Page 4-77
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Appendix A Report Codes
Report Codes
Parameter
Contact ID
SIA
Alarmsȱȱȱ
ȱ
ȱ
Panicȱalarmȱ
120ȱ
PAȱ
Urgentȱ
Panicȱalarmȱrestoreȱ
120ȱ
PHȱ
Urgentȱ
Fireȱalarmȱ
115ȱ
FAȱ
Urgentȱ
Fireȱalarmȱrestoreȱ
115ȱ
FHȱ
Urgentȱ
Medicalȱalarmȱ
100ȱ
MAȱ
Urgentȱ
Medicalȱalarmȱrestoreȱ
100ȱ
MHȱ
Urgentȱ
Duressȱalarmȱ
121ȱ
HAȱ
Urgentȱ
Duressȱalarmȱrestoreȱ
121ȱ
HHȱ
Urgentȱ
Boxȱtamperȱ
137ȱ
TAȱ
Urgentȱ
Boxȱtamperȱrestoreȱ
137ȱ
TRȱ
Urgentȱ
Confirmedȱalarmȱ
139ȱ
BVȱ
Urgentȱ
Confirmedȱalarmȱrestoreȱ
139ȱ
ȱ
Urgentȱ
RecentȱCloseȱ
459ȱ
ȱ
NonȬȱurgentȱ
MainȱFaultsȱȱ
ȱ
ȱ
Lowȱbatteryȱ
302ȱ
YTȱ
NonȬȱurgentȱ
Lowȱbatteryȱrestoreȱ
302ȱ
YRȱ
NonȬȱurgentȱ
ACȱlossȱ
301ȱ
ATȱ
NonȬȱurgentȱ
ACȱrestoreȱ
301ȱ
ARȱ
NonȬȱurgentȱ
Clockȱnotȱsetȱ
626ȱ
ȱ
NonȬȱurgentȱ
Clockȱsetȱ
625ȱ
ȱ
NonȬȱurgentȱ
Falseȱcodeȱ
421ȱ
JAȱ
NonȬȱurgentȱ
Falseȱcodeȱrestoreȱ
421ȱ
ȱ
NonȬȱurgentȱ
Mainȱphoneȱfaultȱ
351ȱ
LTȱ
NonȬȱurgentȱ
Mainȱphoneȱfaultȱrestoreȱ
351ȱ
LRȱ
NonȬȱurgentȱ
RFȱJammingȱ
344ȱ
XQȱ
NonȬȱurgentȱ
RFȱJammingȱrestoreȱ
344ȱ
XHȱ
NonȬȱurgentȱ
GSMȱfaultȱ
330ȱ
IAȱ
NonȬȱurgentȱ
GSMȱfaultȱrestoreȱ
330ȱ
IRȱ
NonȬȱurgentȱ
Page A-1
Report
Category
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Report Codes
Parameter
Contact ID
SIA
Report
Category
GSMȱPreȬAlarmȱ
ȱ
ȱ
NonȬȱurgentȱ
IPȱNetworkȱfaultȱ
ȱ
ȱ
NonȬȱurgentȱ
NonȬȱurgentȱ
IPȱNetworkȱtroubleȱrestoreȱ
ȱ
ȱ
Set/Unsetȱȱ
ȱ
ȱ
UserȱSetȱ
401ȱ
CLȱ
Set/Unsetȱ
UserȱUnsetȱ
401ȱ
OPȱ
Set/Unsetȱ
PartȱSetȱ
441ȱ
CGȱ
Set/Unsetȱ
Unsetȱafterȱalarmȱ
458ȱ
ORȱ
Set/Unsetȱ
KeyswitchȱSetȱ
409ȱ
CSȱ
Set/Unsetȱ
KeyswitchȱUnsetȱ
409ȱ
OSȱ
Set/Unsetȱ
AutoȱSetȱ
403ȱ
CAȱ
Set/Unsetȱ
AutoȱUnsetȱ
403ȱ
OAȱ
Set/Unsetȱ
RemoteȱSetȱ
407ȱ
CLȱ
Set/Unsetȱ
RemoteȱUnsetȱ
407ȱ
OPȱ
Set/Unsetȱ
ForcedȱSetȱ
574ȱ
CFȱ
Set/Unsetȱ
QuickȱSetȱ
408ȱ
CLȱ
Set/Unsetȱ
NoȱSetȱ
654ȱ
CDȱ
Set/Unsetȱ
AutoȱSetȱfailȱ
455ȱ
CIȱ
Set/Unsetȱ
Detectors(Zones)ȱȱ
ȱ
ȱ
Burglaryȱalarmȱ
130ȱ
BAȱ
Burglaryȱalarmȱrestoreȱ
130ȱ
BHȱ
Urgentȱ
Fireȱalarmȱ
110ȱ
FAȱ
Urgentȱ
Fireȱalarmȱrestoreȱ
110ȱ
FHȱ
Urgentȱ
Foilȱalarmȱ
155ȱ
BAȱ
Urgentȱ
Foilȱalarmȱrestoreȱ
155ȱ
BHȱ
Urgentȱ
Panicȱalarmȱ
120ȱ
PAȱ
Urgentȱ
Panicȱalarmȱrestoreȱ
120ȱ
PHȱ
Urgentȱ
Medicalȱalarmȱ
100ȱ
MAȱ
Urgentȱ
Urgentȱ
Medicalȱalarmȱrestoreȱ
100ȱ
MHȱ
Urgentȱ
24ȱHourȱalarmȱ
133ȱ
BAȱ
Urgentȱ
24ȱHourȱalarmȱrestoreȱ
133ȱ
BHȱ
Urgentȱ
Page A-2
AgilityȱEngineerȱManualȱ
ȱ
Report Codes
Parameter
Contact ID
SIA
Report
Category
Entry/Exitȱ
134ȱ
BAȱ
Urgentȱ
Entry/Exitȱrestoreȱ
134ȱ
BHȱ
Urgentȱ
Waterȱ(Flood)ȱalarmȱ
154ȱ
WAȱ
Urgentȱ
Waterȱ(Flood)ȱalarmȱrestoreȱ
154ȱ
WHȱ
Urgentȱ
Gasȱalarmȱ
151ȱ
GAȱ
Urgentȱ
Gasȱalarmȱrestoreȱ
151ȱ
GHȱ
Urgentȱ
CarbonȱMonoxideȱalarmȱ
162ȱ
GAȱ
Urgentȱ
CarbonȱMonoxideȱalarmȱrestoreȱ
162ȱ
GHȱ
Urgentȱ
Environmentalȱalarmȱ
150ȱ
UAȱ
Urgentȱ
Environmentalȱalarmȱrestoreȱ
150ȱ
UHȱ
Urgentȱ
LowȱTemperatureȱ(Freezeȱalarm)ȱ
159ȱ
ZAȱ
Urgentȱ
LowȱTemperatureȱrestoreȱ
159ȱ
ZHȱ
Urgentȱ
HighȱTemperatureȱ
158ȱ
KAȱ
Urgentȱ
HighȱTemperatureȱrestoreȱ
158ȱ
KHȱ
Urgentȱ
Zoneȱfaultȱȱ
380ȱ
UTȱ
Urgentȱ
Zoneȱfaultȱrestoreȱ
380ȱ
UJȱ
Urgentȱ
Burglaryȱfaultȱ
380ȱ
BTȱ
Urgentȱ
Burglaryȱfaultȱrestoreȱ
380ȱ
BJȱ
Urgentȱ
Zoneȱomitȱ
570ȱ
UBȱ
Urgentȱ
Zoneȱomitȱrestoreȱ
570ȱ
UUȱ
Urgentȱ
Burglaryȱomitȱ
573ȱ
BBȱ
Urgentȱ
Burglaryȱomitȱrestoreȱ
573ȱ
BUȱ
Urgentȱ
Zoneȱsupervisionȱlossȱ
381ȱ
UTȱ
Urgentȱ
Zoneȱsupervisionȱrestoreȱȱ
381ȱ
UJȱ
Urgentȱ
Tamperȱ
144ȱ
TAȱ
Urgentȱ
Tamperȱrestoreȱ
144ȱ
TRȱ
Urgentȱ
Zoneȱlostȱ
381ȱ
UTȱ
Urgentȱ
Zoneȱlostȱrestoreȱ
381ȱ
UJȱ
Urgentȱ
Lowȱbatteryȱȱ
384ȱ
XTȱ
NonȬȱurgentȱ
Lowȱbatteryȱrestoreȱ
384ȱ
XRȱ
NonȬȱurgentȱ
Soakȱfailȱ
380ȱ
UTȱ
Urgentȱ
Page A-3
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Report Codes
Parameter
Contact ID
SIA
Report
Category
Soakȱfailȱrestoreȱ
380ȱ
UJȱ
Urgentȱ
ZoneȱAlarmȱ
130ȱ
BAȱ
Urgentȱ
ZoneȱAlarmȱrestoreȱ
130ȱ
BHȱ
Urgentȱ
Zoneȱconfirmȱalarmȱ
139ȱ
BVȱ
Urgentȱ
Zoneȱconfirmȱalarmȱrestoreȱ
139ȱ
ȱ
Urgentȱ
Noȱactivityȱ
393ȱ
NCȱ
Urgentȱ
Noȱactivityȱrestoreȱ
393ȱ
NSȱ
Urgentȱ
WirelessȱKeypadȱȱ
ȱ
ȱ
Tamperȱ
145ȱ
TAȱ
Urgentȱ
Tamperȱrestoreȱ
145ȱ
TRȱ
Urgentȱ
Lowȱbatteryȱ
384ȱ
XTȱ
NonȬȱurgentȱ
Lowȱbatteryȱrestoreȱ
384ȱ
XRȱ
NonȬȱurgentȱ
Keypadȱlostȱ
355ȱ
BZȱ
Urgentȱ
Keypadȱlostȱrestoreȱ
355ȱ
ȱ
Urgentȱ
WirelessȱKeyfobȱȱ
ȱ
ȱ
Setȱ
409ȱ
CSȱ
Set/Unsetȱ
Unsetȱ
409ȱ
OSȱ
Set/Unsetȱ
Lowȱbatteryȱȱ
384ȱ
XTȱ
NonȬȱurgentȱ
Lowȱbatteryȱrestoreȱ
384ȱ
XRȱ
NonȬȱurgentȱ
WirelessȱSounderȱ
ȱ
ȱ
Tamperȱ
145ȱ
TAȱ
Urgentȱ
Tamperȱrestoreȱ
145ȱ
TRȱ
Urgentȱ
Lowȱbatteryȱ
384ȱ
XTȱ
NonȬȱurgentȱ
Lowȱbatteryȱrestoreȱ
384ȱ
XRȱ
NonȬȱurgentȱ
Sounderȱlostȱ
355ȱ
BZȱ
Urgentȱ
Sounderȱlostȱrestoreȱ
355ȱ
ȱ
Urgentȱ
WirelessȱI/OȱExpanderȱ
ȱ
ȱ
Lowȱbatteryȱ
384ȱ
XTȱ
NonȬȱurgentȱ
Lowȱbatteryȱrestoreȱ
384ȱ
XRȱ
NonȬȱurgentȱ
I/OȱExpanderȱlostȱ
355ȱ
BZȱ
Urgentȱ
I/OȱExpanderȱlostȱrestoreȱ
355ȱ
ȱ
Urgentȱ
Page A-4
AgilityȱEngineerȱManualȱ
ȱ
Report Codes
Parameter
Contact ID
SIA
Report
Category
Tamperȱ
145ȱ
TAȱ
Urgentȱ
Tamperȱrestoreȱ
145ȱ
TRȱ
Urgentȱ
ACȱfaultȱ
301ȱ
ATȱ
NonȬȱurgentȱ
ACȱfaultȱrestoreȱ
301ȱ
ARȱ
NonȬȱurgentȱ
RFȱJammingȱ
380ȱ
XQȱ
Urgentȱ
RFȱJammingȱrestoreȱ
380ȱ
XHȱ
Urgentȱ
Miscellaneousȱȱ
ȱ
ȱ
Enterȱprogrammingȱ(Local)ȱ
627ȱ
LBȱ
Set/Unsetȱ
Exitȱprogrammingȱ(Local)ȱ
628ȱ
LSȱ(LXȱ)ȱ
Set/Unsetȱ
Enterȱprogrammingȱ(Remote)ȱ
627ȱ
RBȱ
Set/Unsetȱ
Exitȱprogrammingȱ(Remote)ȱ
628ȱ
RSȱ
Set/Unsetȱ
ARCȱperiodicȱtestȱ
602ȱ
RPȱ
NonȬȱurgentȱ
ARCȱkeepȱaliveȱ(polling)ȱ
999ȱ
ZZȱ
Urgentȱ
Callȱbackȱ
411ȱ
RBȱ
NonȬȱurgentȱ
Systemȱresetȱ
305ȱ
RRȱ
Urgentȱ
Listenȱinȱbeginȱ
606ȱ
LFȱ
Urgentȱ
CancelȱReportȱ
406ȱ
OCȱ
Urgentȱ
WalkȱTestȱ
607ȱ
BCȱ
NonȬȱurgentȱ
WalkȱTestȱrestoreȱ
607ȱ
ȱ
NonȬȱurgentȱ
ExitȱErrorȱ
374ȱ
ȱ
NonȬȱurgentȱ
ȱ
ȱ
Page A-5
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Appendix B Engineer Event Log Messages
EventȱMessageȱ
ActivateȱPO=xxȱȱȱ
ActvȱPO=xxȱKF=zzȱ
AlarmȱabortȱP=yȱȱ
Descriptionȱ
POȱXXȱactivationȱ
POȱXXȱisȱactivatedȱfromȱremoteȱcontrolȱZZȱ
AlarmȱabortedȱonȱpartitionȱYȱ
AlarmȱZone=xxȱȱȱȱ
AntiȬcodeȱresetȱȱ
ARC=yȱcallȱerrorȱ
ARC=yȱrestoreȱ
AutoȱAddȱGSMȱȱȱȱȱ
AutoȱAddȱIPȱcardȱ
AutoȱAddȱMODEMȱȱȱ
AutoȱDelȱGSMȱȱȱȱȱ
AutoȱDelȱIPȱcardȱ
AutoȱDelȱMODEMȱȱȱ
Autoȱtestȱfailȱȱȱ
AutoȱtestȱOKȱȱȱȱȱ
Bellȱtamperȱȱ
Bellȱtamperȱrstȱȱ
Boxȱtamperȱȱȱȱȱȱȱ
Boxȱtamperȱrstȱȱȱ
Alarmȱinȱzoneȱno.ȱXXȱ
Remoteȱresetȱ
CommunicationȱfailȱfaultȱtoȱARCȱphoneȱno.ȱYȱ
CommunicationȱfailȱfaultȱrestoreȱtoȱARCȱphoneȱno.ȱYȱ
GSMȱModuleȱaddedȱtoȱtheȱmainȱunitȱ
IPȱModuleȱaddedȱtoȱtheȱmainȱunitȱ
Modemȱaddedȱtoȱtheȱmainȱunitȱ
GSMȱModuleȱwasȱremovedȱfromȱtheȱmainȱunitȱ
IPȱModuleȱremovedȱfromȱtheȱmainȱunitȱ
Modemȱremovedȱfromȱtheȱmainȱunitȱ
FailureȱofȱzoneȱselfȬtestȱ
AutomaticȱzoneȱselfȬtestȱOKȱ
Bellȱtamperȱalarmȱ
Bellȱtamperȱalarmȱrestoreȱ
Boxȱtamperȱalarmȱfromȱmainȱunitȱ
Boxȱtamperȱalarmȱrestoreȱ
CancelȱAlarmȱP=xȱ
CancelȱalarmȱeventȱhasȱoccurredȱfromȱpartitionȱX.ȱAȱvalidȱ
userȱfunctionȱisȱenteredȱtoȱresetȱtheȱalarmȱafterȱtheȱdefinedȱ
Abortȱalarmȱtimeȱ
ChangingȱuserȱcodeȱXXȱ
ChangingȱFollowȬMeȱnumberȱYYȱbyȱuserȱno.ȱXXȱ
ChangingȱkeypadȱtagȱforȱuserȱXXȱ
Timeȱisȱnotȱsetȱ
Timeȱdefinedȱbyȱuserȱno.ȱXXȱ
COȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱCOȱdetectorȱ
COȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱCOȱdetectorȱ
CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱIPȱcardȱ
CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱSounderȱYȱ
CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱGSMȱ
CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱI/Oȱmoduleȱ
ConfirmedȱalarmȱoccurredȱinȱpartitionȱYȱ
Restoreȱzoneȱconfirmedȱalarmȱ
ConfirmedȱalarmȱoccurredȱfromȱzoneȱXXȱ
Theȱcontrolȱpanelȱhasȱresetȱ
Dateȱdefinedȱbyȱuserȱno.ȱXXȱ
DailyȱsetȱonȱpartitionȱYȱ
DailyȱPartȱSettingȱinȱpartitionȱYȱȱ
Changeȱcode=xxȱȱȱ
ChangeȱFM=yyȱC=xxȱȱȱȱȱ
Changeȱtag=xxȱȱȱȱ
Clockȱnotȱsetȱȱȱȱ
ClockȱsetȱC=xxȱȱȱ
COȱAlarmȱZn=xxȱȱȱ
COȱRst.ȱZn=xxȱȱȱȱ
ComȱokȱIPȱcardȱȱȱ
CommȱOKȱSoundr=yȱ
Comm.ȱOKȱGSMȱȱȱȱȱ
Comm.OKȱI/OȱMdl.ȱ
Conf.ȱalarmȱP=yȱȱ
ConfirmȱrsȱZ=xxȱȱ
ConfirmȱZone=xxȱȱ
CPȱresetȱȱȱȱȱȱȱȱȱ
DateȱsetȱC=xxȱȱȱȱ
DayȱF.Set:P=yȱȱȱȱȱ
DayȱP.Set:P=yȱȱȱ
Page B-1
ȱ
AgilityȱEngineerȱManualȱ
ȱ
EventȱMessageȱ
DayȱUnset:ȱP=yȱȱȱȱȱ
DuressȱC=xxȱȱȱȱȱȱ
Enterȱprogramȱȱȱȱ
ExitȱErrorȱZn=xxȱ
Exitȱprogramȱȱȱȱȱ
F.FaultȱOKȱZ=xxȱ
Descriptionȱ
DailyȱunsetȱonȱpartitionȱYȱ
Duressȱalarmȱfromȱuser no.ȱXXȱ
Enteringȱengineerȱprogrammingȱfromȱkeypadȱorȱ
configurationȱsoftwareȱ
ExitȱerrorȱeventȱfromȱzoneȱXXȱ
Theȱzoneȱwasȱleftȱopenȱatȱtheȱendȱofȱtheȱexitȱtimeȱ
Exitingȱengineerȱprogrammingȱfromȱkeypadȱorȱ
configurationȱsoftwareȱ
Restoreȱfireȱalarmȱinȱzoneȱno.ȱXXȱ
F.SetȱfailȱP=yȱ
PartitionȱYȱfailedȱtoȱsetȱ
F.Set:P=yȱC=xxȱ
PartitionȱYȱsetȱbyȱuserȱno.ȱXXȱ
F.Set:P=yȱKF=zzȱ
PartitionȱYȱsetȱbyȱremoteȱcontrolȱZZȱ
Falseȱcodeȱȱȱȱȱȱȱ
Falseȱcodeȱalarmȱ
Falseȱcodeȱrest.ȱȱȱȱ
FireȱfaultȱZn=xxȱ
FireȱKeypad=yȱȱȱȱ
FireȱZone=xxȱȱȱȱȱ
FoilȱokȱZ=xxȱȱȱȱȱ
Falseȱcodeȱalarmȱrestoreȱ
Faultȱinȱfireȱzoneȱno.ȱXXȱ
FireȱalarmȱfromȱwirelessȱkeypadȱYȱ
Fireȱalarmȱinȱzoneȱno.ȱXXȱ
Restoreȱinȱfoilȱ(Day)ȱzoneȱno.ȱXXȱ
FoilȱZone=xxȱȱȱȱȱ
ForcedȱsetȱP=yȱȱȱȱȱȱ
FoundȱZone=xxȱȱȱȱ
GasȱAlarmȱZn=xxȱȱ
Faultȱinȱfoilȱ(Day)ȱzoneȱno.ȱXXȱ
PartitionȱYȱisȱforceȱsetȱ
Wirelessȱzoneȱfound,ȱzoneȱno.ȱXXȱ
Gasȱ(naturalȱgas)ȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱgasȱ
detectorȱ
Gasȱ(naturalȱgas)ȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ
gasȱdetectorȱ
IPȱaddressȱisȱincorrectȱ
IPȱconnectionȱOKȱ
CommunicationȱbetweenȱtheȱGSM/GPRSȱModuleȱandȱtheȱ
AgilityȱisȱOKȱ
InternalȱGSM/GPRSȱBUSȱmoduleȱfaultȱ
GSMȱnetworkȱisȱnotȱavailableȱ
GSMȱNetworkȱisȱavailableȱ
GSMȱNetworkȱqualityȱisȱacceptableȱ
TheȱGSMȱRSSIȱlevelȱisȱlowȱ
GasȱRst.ȱZn=xxȱȱȱ
GSM:IPȱFaultȱ
GSM:IPȱOKȱȱȱȱȱȱȱȱ
GSM:Mdlȱcomm.OKȱȱ
GSM:ȱModuleȱcomm.ȱ
GSM:NETȱavail.ȱȱȱ
GSM:NETȱavail.OKȱ
GSM:NETȱqual.OKȱȱ
GSM:NETȱqualityȱȱ
GSM:PINȱcodeȱerrȱ
GSM:PINȱcodeȱOKȱȱ
GSM:PUKȱCodeȱerrȱ
GSM:PUKȱCodeȱOKȱȱ
GSM:SIMȱfaultȱ
GSM:SIMȱOKȱȱȱȱȱȱȱ
H.TempȱrstȱZn=xxȱ
PINȱcodeȱenteredȱisȱincorrectȱ
PINȱcodeȱisȱcorrectȱ
PUKȱcodeȱrequiredȱ
PUKȱCodeȱenteredȱisȱcorrect
SIMȱcardȱmissingȱorȱnotȱproperlyȱsitedȱ
SIMȱCardȱinȱplaceȱ
HighȱtemperatureȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ
temperatureȱdetectorȱ
Page B-2
AgilityȱEngineerȱManualȱ
EventȱMessageȱ
HighȱTemp.ȱZn=xxȱ
ȱ
IPC:ȱARC=xȱErrorȱ
IPC:ȱARC=xȱOKȱ
IPC:ȱDHCPȱerrorȱȱȱ
IPC:ȱDHCPȱokȱȱȱȱȱȱ
Descriptionȱ
HighȱtemperatureȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱ
temperatureȱdetectorȱ
ACȱpowerȱfaultȱonȱI/Oȱmoduleȱ
ACȱpowerȱrestoreȱonȱI/Oȱmoduleȱ
I/Oȱmoduleȱbatteryȱfaultȱalertȱ
I/Oȱmoduleȱbatteryȱfaultȱrestoredȱȱ
I/Oȱmoduleȱcommunicationȱfaultȱrestoredȱ
I/Oȱmoduleȱcommunicationȱfaultȱ
I/Oȱmoduleȱjammingȱalertȱ
I/Oȱmoduleȱjammingȱalertȱrestoredȱ
I/Oȱmoduleȱisȱregardedȱasȱlostȱfollowingȱsupervisionȱtestȱ
I/Oȱmoduleȱtamperȱalertȱ
I/Oȱmoduleȱtamperȱalertȱrestoredȱ
TheȱAgilityȱreceivedȱaȱsignalȱfromȱI/Oȱmoduleȱafterȱitȱhasȱ
beenȱregardedȱasȱlostȱ
CommunicationȱfailureȱtoȱARCȱXȱoverȱIPȱnetworkȱ
CommunicationȱtoȱARCȱXȱoverȱIPȱnetworkȱisȱOKȱ
FailedȱtoȱacquireȱanȱIPȱaddressȱfromȱtheȱDHCPȱserverȱ
SucceeededȱtoȱacquireȱanȱIPȱaddressȱfromȱtheȱDHCPȱserverȱ
IPC:ȱDownloadȱerrȱ
IPC:ȱDownloadȱokȱȱ
IPC:ȱHardwareȱerrȱ
IPC:ȱHardwareȱokȱȱ
IPC:ȱMailȱerrorȱȱȱ
IPC:ȱMailȱokȱȱȱȱȱȱ
Failedȱtoȱdownloadȱfromȱupgradeȱserverȱ
Successfulȱdownloadȱfromȱupgradeȱserverȱ
InternalȱhardwareȱerrorȱinȱtheȱIPȱcardȱ
NoȱhardwareȱerrorȱinȱtheȱIPȱcardȱ
IPȱcardȱfailedȱtoȱsendȱanȱEmailȱ
IPȱcardȱsuccessfullyȱsentȱanȱEmailȱ
IPC:ȱNetworkȱerrȱȱ
IPC:ȱNetworkȱokȱȱȱ
IPC:ȱNTPȱerrorȱȱȱȱ
IPC:ȱNTPȱokȱȱȱȱȱȱȱ
IPC:ȱUpgradeȱerrȱȱ
FailedȱtoȱconnectȱtoȱIPȱnetworkȱ
SuccessfulȱconnectionȱtoȱIPȱnetworkȱ
Failedȱtoȱacquireȱtimeȱdataȱfromȱtheȱtimeȱserverȱ
Succeededȱtoȱacquireȱtimeȱdataȱfromȱtheȱtimeȱserverȱ
RemoteȱsoftwareȱupgradeȱofȱtheȱIPȱcardȱfailedȱ
IPC:ȱUpgradeȱokȱȱȱ
JammingȱOKȱZn=xxȱ
Jammingȱrestoreȱȱ
RemoteȱsoftwareȱupgradeȱofȱtheȱIPȱcardȱsucceededȱȱ
ZoneȱXXȱjammingȱOKȱ
Wirelessȱreceiverȱȱjammingȱrestoreȱ
JammingȱZone=xxȱȱȱȱȱ
KP=yȱLowȱBat.Rstȱ
KP=yȱLowȱBatteryȱ
KswȱF.Set:P=yȱȱȱȱȱ
KswȱUnset:P=yȱȱȱ
L.batȱrstrȱKF=yyȱ
L.TempȱrstȱZn=xxȱ
ZoneȱXXȱjammingȱfaultȱ
LowȱbatteryȱfaultȱrestoredȱfromȱkeypadȱYȱ
LowȱbatteryȱfaultȱfromȱkeypadȱYȱ
PartitionȱYȱisȱsetȱbyȱkeyȱswitchȱ
PartitionȱYȱisȱunsetȱbyȱkeyȱswitchȱ
LowȱbatteryȱfaultȱrestoreȱfromȱwirelessȱremoteȱcontrolȱYYȱ
LowȱtemperatureȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ
temperatureȱdetectorȱ
IfȱtheȱphoneȱlineȱisȱcutȱorȱtheȱDCȱlevelȱisȱunderȱ1Vȱ
I/O:ȱACȱFaultȱ
I/O:ȱACȱRestoreȱȱȱȱȱȱ
I/O:ȱBatteryȱFltȱ
I/O:ȱBateryȱRstrȱ
I/O:ȱCommȱRestoreȱ
I/O:ȱComm.ȱFaultȱȱ
I/O:ȱJammingȱȱȱȱȱȱ
I/O:ȱJammingȱRstrȱ
I/O:ȱLostȱȱȱȱȱȱȱȱȱ
I/O:ȱTamperȱȱȱȱȱȱȱ
I/O:ȱTamperȱRstrȱȱ
I/O:ȱLostȱRestoreȱȱ
Lineȱfaultȱ
Page B-3
ȱ
AgilityȱEngineerȱManualȱ
ȱ
EventȱMessageȱ
Lineȱrestoreȱ
LostȱZone=xxȱȱȱȱȱ
LowȱBatȱrsȱZ=xxȱȱ
Lowȱbat.ȱZn=xxȱȱȱ
Lowȱbat.KF=yyȱȱȱȱ
LowȱTemp.ȱZn=xxȱȱ
Main:ACȱlostȱ
Main:ACȱrestoreȱȱ
Main:ȱbatteryȱrstȱ
Main:ȱlowȱbatteryȱ
MsgȱBoxȱTamperȱ
MsgȱBoxȱTmpȱRst.ȱ
NoȱComȱIPȱcardȱȱȱ
NoȱcommȱI/OȱMdl.ȱ
NoȱcommȱSoundr=yȱȱ
Noȱcomm.ȱGSMȱȱȱȱȱ
OmitȱBox+Bellȱ
OmitȱFaultȱC=xxȱ
OmitȱZone=xxȱ
P.Set:P=yȱC=zzȱȱȱȱ
P.Set:ȱP=yȱKF=zzȱȱȱ
PanicȱKeypad=yȱȱ
PanicȱKF=yyȱȱȱȱȱ
PTM:ȱSendȱDataȱȱȱȱ
Radioȱl.batȱȱS=yȱ
Radioȱl.batȱrS=yȱ
RemoteȱF.Set:P=yȱȱ
RemoteȱP.Set:P=yȱ
Remoteȱprogramȱȱȱ
RemoteȱUnset:P=xȱ
RestoreȱZone=xxȱȱ
RFȱJammingȱȱȱȱȱȱȱ
Sndr=yȱLostȱRstȱ
SoakȱfailȱZ=xxȱȱȱ
Sounder=yȱLostȱȱȱȱȱ
SpecialȱKP=yȱȱȱȱȱ
Descriptionȱ
Phoneȱlineȱfaultȱrestoreȱ
Wirelessȱzoneȱlost,ȱzoneȱno.ȱXXȱ
Lowȱbatteryȱfaultȱrestoredȱfromȱwirelessȱzoneȱno.ȱXXȱ
Lowȱbatteryȱfaultȱfromȱwirelessȱzoneȱno.ȱXXȱ
LowȱbatteryȱfaultȱfromȱwirelessȱremoteȱcontrolȱXXȱ
LowȱtemperatureȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱ
temperatureȱdetectorȱ
LossȱofȱACȱpowerȱfromȱtheȱmainȱpanelȱ
ACȱpowerȱrestoreȱonȱmainȱpanelȱ
Lowȱbatteryȱfaultȱrestoreȱfromȱtheȱmainȱpanelȱ
Lowȱbatteryȱfaultȱfromȱtheȱmainȱpanelȱ
TamperȱalarmȱfromȱtheȱListenȱInȱmessageȱboxȱunitȱ
TamperȱalarmȱrestoreȱfromȱtheȱListenȱInȱmessageȱboxȱunitȱ
CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱIPȱcardȱ
CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱI/Oȱ
moduleȱ
CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱsounderȱYȱ
NoȱcommunicationȱbetweenȱtheȱGSM/GPRSȱModuleȱandȱ
theȱAgilityȱ
Boxȱ+ȱBellȱtamperȱisȱomittedȱ
SystemȱfaultsȱwereȱomittedȱbyȱuserȱXXȱ
Zoneȱno.ȱXXȱisȱomittedȱ
PartitionȱYȱpartȱsetȱbyȱuserȱZZȱ
PartitionȱYȱpartȱsetȱbyȱremoteȱcontrolȱZZȱ
PanicȱalarmȱfromȱwirelessȱkeypadȱYȱȱ
PanicȱalarmȱfromȱremoteȱcontrolȱYYȱ
LoadȱnewȱparametersȱintoȱtheȱAgilityȱfromȱPTMȱaccessoryȱȱ
RadioȱlowȱbatteryȱfaultȱfromȱsounderȱYȱ
RadioȱlowȱbatteryȱrestoreȱfromȱsounderȱYȱ
Theȱsystemȱhasȱbeenȱsetȱfromȱtheȱconfigurationȱsoftwareȱ
TheȱsystemȱhasȱbeenȱsetȱinȱPartȱSetȱmodeȱfromȱtheȱ
configurationȱsoftwareȱ
Theȱsystemȱhasȱbeenȱprogrammedȱfromȱtheȱconfigurationȱ
softwareȱ
PartitionȱYȱunsetȱfromȱtheȱconfigurationȱsoftwareȱ
Alarmȱrestoreȱinȱzoneȱno.ȱXXȱ
Wirelessȱreceiverȱjammingȱ
TheȱAgilityȱreceivedȱaȱsignalȱfromȱsounderȱYȱafterȱitȱhasȱ
beenȱregardedȱasȱlostȱ
ZoneȱXXȱhasȱfailedȱinȱtheȱsoakȱtestȱ
SounderȱYȱisȱregardedȱasȱlostȱfollowingȱsupervisionȱtestȱ
SpecialȱalarmȱfromȱtheȱfromȱwirelessȱkeypadȱYȱȱ
Page B-4
AgilityȱEngineerȱManualȱ
ȱ
EventȱMessageȱ
Spkrȱl.batȱrsS=yȱ
SpkrȱlowȱbatȱS=yȱ
StartȱexitȱP=yȱȱȱ
TamperȱI/OȱMdl.ȱȱ
TamperȱI/OȱMdl.ȱȱȱ
Descriptionȱ
SpeakerȱlowȱbatteryȱrestoreȱfromȱsounderȱYȱ
SpeakerȱlowȱbatteryȱfaultȱfromȱsounderȱYȱ
ExitȱtimeȱstartedȱinȱpartitionȱYȱ
TamperȱalarmȱfromȱI/Oȱmoduleȱ
TamperȱalarmȱrestoredȱfromȱI/Oȱmoduleȱ
TamperȱKeypad=yȱȱ
TamperȱrsȱZn=xxȱȱ
TamperȱrstȱKP=yȱȱ
TamperȱSounder=yȱȱȱ
TamperȱZone=xxȱȱȱ
TechȱalarmȱZn=xxȱ
TechȱrstrȱȱZn=xxȱ
TmpȱrstrȱSndr=yȱ
UnȬOmitȱZone=xxȱ
UnOmtȱBox+Bellȱ
Unknownȱeventȱȱȱȱ
Unset:P=yȱC=zz
Unset:ȱP=yȱKF=zz
UserȱloginȱC=xxȱȱ
TamperȱalarmȱfromȱkeypadȱID=Yȱ
Tamperȱalarmȱrestoreȱonȱzoneȱno.ȱXXȱ
KeypadȱYȱtamperȱrestoreȱ
TamperȱalarmȱfromȱwirelessȱsounderȱYȱ
Tamperȱalarmȱfromȱzoneȱno.ȱXXȱ
AlarmȱfromȱzoneȱXXȱdefinedȱasȱTechnicalȱ
AlarmȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱTechnicalȱ
TamperȱalarmȱrestoreȱfromȱwirelessȱsounderȱYȱ
Zoneȱno.ȱXXȱisȱreinstatedȱfromȱomitȱ
Boxȱ+ȱBellȱreinstatedȱfromȱomitȱ
Unknownȱeventȱalertȱ
PartitionȱYȱunsetȱbyȱuserȱZZȱ
PartitionȱYȱunsetȱbyȱremoteȱcontrolȱZZȱ
UserȱXXȱhasȱenteredȱintoȱprogrammingȱmode.ȱUserȱ99ȱ
representsȱremoteȱprogrammingȱfromȱtheȱconfigurationȱ
softwareȱ
Floodȱalarmȱfromȱzoneȱno.ȱXXȱ
Floodȱalarmȱrestoreȱonȱzoneȱno.ȱXXȱ
ZoneȱselfȬtestȱfailed,ȱzoneȱno.ȱXXȱ
ZoneȱselfȬtestȱOK,ȱzoneȱno.ȱXXȱ
ZoneȱfaultȱeventȱfromȱzoneȱXXȱ
ZoneȱfaultȱeventȱrestoreȱfromȱzoneȱXXȱ
WaterȱAlrmȱZn=xxȱ
WaterȱrstrȱZn=xxȱ
Z=xxȱautoȱbadȱȱȱȱ
Z=xxȱautoȱokȱȱȱȱȱ
Zn=xxȱFaultȱ
Zn=xxȱFaultȱOKȱ
ȱ
Page B-5
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Appendix C Library Voice Messages
001ȱ
002ȱ
003ȱ
004ȱ
005ȱ
Aȱ
006ȱ
007ȱ
008ȱ
009ȱ
010ȱ
011ȱ
012ȱ
013ȱ
014ȱ
Bȱ
015ȱ
016ȱ
017ȱ
018ȱ
019ȱ
020ȱ
021ȱ
022ȱ
023ȱ
024ȱ
025ȱ
026ȱ
027ȱ
028ȱ
029ȱ
030ȱ
Cȱ
031ȱ
032ȱ
033ȱ
034ȱ
035ȱ
036ȱ
Customȱ
Customȱ
Customȱ
Customȱ
Customȱ
ȱ
Aȱ
Aboveȱȱ
Airȱconditionerȱ
Anȱ
Andȱ
Apartmentȱ
Areaȱ
Atȱ
Atticȱ
ȱ
Babyȇsȱroomȱ
Backȱ
Baggageȱ
Balconyȱ
Barȱ
Barnȱ
Basementȱ
Bathroomȱ
Bedroomȱ
Beforeȱ
Behindȱ
Bottomȱ
Boyȇsȱroomȱ
Branchȱ
Buildingȱ
Byȱ
ȱ
Cabinetȱ
Cafeȱ
Cameraȱ
Canteenȱ
Ceilingȱ
Cellarȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
037ȱ
038ȱ
039ȱ
040ȱ
041ȱ
042ȱ
043ȱ
044ȱ
045ȱ
046ȱ
047ȱ
048ȱ
049ȱ
Dȱ
050ȱ
051ȱ
052ȱ
053ȱ
054ȱ
055ȱ
056ȱ
057ȱ
058ȱ
Eȱ
059ȱ
060ȱ
061ȱ
062ȱ
063ȱ
064ȱ
065ȱ
066ȱ
067ȱ
068ȱ
Fȱ
069ȱ
070ȱ
071ȱ
072ȱ
CentralȱHeatingȱ
Childrenȱ
Classroomȱ
Cleanerȱ
COȱ
Computerȱroomȱ
Conferenceȱ
Conservatoryȱ
Contactȱ
Containerȱ
Controlȱ
Cornerȱ
Curtainȱ
ȱ
Deskȱ
Detectorȱ
Deviceȱ
Diningȱ
Doorȱ
Downȱ
Downstairsȱ
Dressingȱ
Driveȱ
ȱ
Eastȱ
Elementȱ
Emergencyȱ
Engineȱ
Entranceȱ
Entryȱ
Escapeȱ
Executiveȱ
Exitȱ
Externalȱ
ȱ
Familyȱ
Fenceȱ
Fireȱ
Firstȱ
ȱ
Page C-1
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
073ȱ
074ȱ
075ȱ
076ȱ
077ȱ
078ȱ
Gȱ
079ȱ
080ȱ
081ȱ
082ȱ
083ȱ
084ȱ
085ȱ
086ȱ
087ȱ
088ȱ
089ȱ
090ȱ
Hȱ
091ȱ
092ȱ
093ȱ
094ȱ
095ȱ
Iȱ
096ȱ
097ȱ
098ȱ
099ȱ
100ȱ
101ȱ
Kȱ
102ȱ
Lȱ
103ȱ
104ȱ
105ȱ
106ȱ
Floodȱ
Floorȱ
Forȱ
Foyerȱ
Freezerȱ
Frontȱ
ȱ
Gamesȱ
Garageȱ
Gardenȱ
Gasȱ
Gateȱ
Gentsȱ
Girlȇsȱroomȱ
Glassȱ
Groceryȱ
Groundȱ
Guestȱ
Gymȱ
ȱ
Hallȱ
Hallwayȱ
Hangerȱ
Highȱ
Houseȱ
ȱ
Inȱ
Indoorȱ
Insideȱ
Interiorȱ
Internalȱ
Isȱ
ȱ
Kitchenȱ
ȱ
Labȱ
Ladiesȱ
Landingȱ
Laundryȱ
ȱ
AgilityȱEngineerȱManualȱ
ȱ
107ȱ
108ȱ
109ȱ
110ȱ
111ȱ
112ȱ
113ȱ
114ȱ
Mȱ
115ȱ
116ȱ
117ȱ
118ȱ
119ȱ
120ȱ
121ȱ
122ȱ
123ȱ
Nȱ
124ȱ
125ȱ
126ȱ
127ȱ
Oȱ
128ȱ
129ȱ
130ȱ
131ȱ
132ȱ
133ȱ
134ȱ
Pȱ
135ȱ
136ȱ
137ȱ
138ȱ
139ȱ
Lavatoryȱ
Leftȱ
Libraryȱ
Liftȱ
Lightȱ
Livingȱ
Lobbyȱ
Lowȱ
ȱ
Machineȱ
Macroȱ
Magnetȱ
Maidȇsȱroomȱ
Mainȱ
Masterȱ
Medicalȱ
Middleȱ
Motionȱ
ȱ
Nearȱ
Newȱ
Northȱ
Nurseryȱ
ȱ
Ofȱ
Officeȱ
Onȱ
Outbuildingȱ
Outdoorȱ
Outputȱ
Outsideȱ
ȱ
Panicȱ
Partitionȱ
Passageȱ
Patioȱ
Perimeterȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
140ȱ
141ȱ
Rȱ
142ȱ
143ȱ
144ȱ
145ȱ
146ȱ
147ȱ
148ȱ
149ȱ
Sȱ
150ȱ
151ȱ
152ȱ
153ȱ
154ȱ
155ȱ
156ȱ
157ȱ
158ȱ
159ȱ
160ȱ
161ȱ
162ȱ
163ȱ
164ȱ
165ȱ
166ȱ
167ȱ
Tȱ
168ȱ
169ȱ
170ȱ
171ȱ
172ȱ
173ȱ
Poolȱ
Porchȱ
ȱ
Rearȱ
Receptionȱ
Refrigeratorȱ
Relayȱ
Restaurantȱ
Rightȱ
Roofȱ
Roomȱ
ȱ
Safeȱ
Safetyȱ
Secondȱ
Shedȱ
Shockȱ
Shopȱ
Shutterȱ
Sideȱ
Siteȱ
Smokeȱ
Southȱ
Spaceȱ
Sprinklerȱ
Stairsȱ
Storeȱ
Studentȱroomȱ
Studyȱ
Suiteȱ
ȱ
Technicalȱ
Temperatureȱ
Thirdȱ
Toȱ
Topȱ
TVȱ
ȱ
Page C-2
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Uȱ
ȱ
174ȱ Underȱ
175ȱ Upȱ
176ȱ Upstairsȱ
177ȱ Utilityȱ
Vȱ
ȱ
178ȱ Vestibuleȱ
179ȱ Videoȱcameraȱ
Wȱ
ȱ
180ȱ Wallȱ
181ȱ Warehouseȱ
182ȱ Washroomȱ
183ȱ Westȱ
184ȱ Windowȱ
Yȱ
ȱ
185ȱ Yardȱ
Zȱ
ȱ
ȱ 186ȱ Zoneȱ
ȱȱȱȱȱNumbersȱ
ȱ 187ȱ 0ȱ
ȱ 188ȱ 1ȱ
ȱ 189ȱ 2ȱ
ȱ 190ȱ 3ȱ
ȱ 191ȱ 4ȱ
ȱ 192ȱ 5ȱ
ȱ 193ȱ 6ȱ
ȱ 194ȱ 7ȱ
ȱ 195ȱ 8ȱ
ȱ 196ȱ 9ȱ
ȱ 197ȱ 10ȱ
ȱ ȱ
ȱ
ȱ ȱ
ȱ
ȱ ȱ
ȱ
ȱ ȱ
ȱ
ȱ ȱ
ȱ
ȱ ȱ
ȱ
ȱ ȱ
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Appendix D EN 50131 Compliance
Compliance Statement
Hereby,ȱRISCOȱGroupȱdeclaresȱthatȱtheȱAgilityȱseriesȱofȱcentralȱunitsȱandȱaccessoriesȱareȱ
designedȱtoȱcomplyȱwith:ȱ
EN50131Ȭ1,ȱEN50131Ȭ3ȱGradeȱ2ȱ
EN50130Ȭ5ȱEnvironmentalȱclassȱIIȱȱ
EN50131Ȭ6ȱTypeȱAȱ
UK:ȱDD243:2004,ȱPDȱ6662:2004,ȱACPOȱ(Police)ȱ
USA:ȱFCC:ȱPartȱ15B,ȱFCCȱpartȱ68ȱȱ
CANADA:ȱCSȬ03,ȱDCȬ01ȱ
Possible logical keys calculations:
LogicalȱcodesȱareȱcodesȱenteredȱatȱtheȱwirelessȱkeypadȱtoȱallowȱLevelȱ2ȱ(users)ȱandȱ
Levelȱ3ȱ(engineer)ȱaccess.ȱ
Allȱcodeȱlengthsȱareȱ4ȱdigitsȱlongȱ
0Ȭ9ȱcanȱbeȱusedȱforȱeachȱdigit.ȱ
ThereȱareȱnoȱdisallowedȱcodesȱȬȱcodesȱfromȱ0001ȱtoȱ9999ȱareȱacceptable.ȱ
Invalidȱcodesȱcannotȱbeȱcreatedȱdueȱtoȱtheȱfactȱthatȱafterȱtheȱcodeȱ4thȱdigitȱhasȱbeenȱ
pressed,ȱȈEnterȈȱisȱautomaticallyȱapplied.ȱCodeȱisȱrejectedȱwhenȱtryingȱtoȱcreateȱaȱ
nonȱexistingȱcode.ȱ
Possible physical keys calculations:
PhysicalȱkeysȱareȱimplementedȱinȱtheȱWirelessȱKeyfobs.ȱ
ItȱisȱassumedȱthatȱonlyȱaȱuserȱpossessesȱaȱKeyfobs,ȱthereforeȱaȱphysicalȱkeyȱisȱ
consideredȱasȱaccessȱLevelȱ2ȱ
EachȱKeyfobȱhasȱ24ȱbitȱidentificationȱcodeȱcomprisingȱ2^24ȱoptions.ȱ
AȱKeyfobȱhasȱtoȱbeȱrecognizedȱandȱregisteredȱbyȱtheȱAgility,ȱtherefore,ȱaȱȈwriteȈȱ
processȱmustȱbeȱperformed.ȱȱ
AȱvalidȱKeyfobȱisȱoneȱȈLearnedȈȱbyȱtheȱpanelȱandȱallowingȱSet/Unsetȱ
AȱnonȱvalidȱKeyfobȱisȱoneȱnotȱȈLearnedȈȱbyȱtheȱpanelȱandȱnotȱallowingȱSet/Unset.ȱ
System Monitoring
TheȱmainȱunitȱisȱmonitoredȱforȱACȱfault,ȱbatteryȱfault,ȱlowȱbatteryȱandȱmore.ȱȱ
TheȱI/OȱWirelessȱExpanderȱisȱmonitoredȱforȱACȱfault,ȱbatteryȱfault,ȱlowȱbatteryȱandȱ
more.ȱ
Allȱotherȱwirelessȱelementsȱareȱmonitoredȱforȱlowȱvoltageȱbattery.
Page D-1
ȱ
AgilityȱEngineerȱManualȱ
ȱ
Setting the Agility to comply with EN 50131 requirements
1.
2.
3.
4.
5.
AccessȱtheȱEngineerȱprogrammingȱmode.ȱ
Fromȱtheȱ[1]ȱSystemȱmenuȱselectȱ[5]ȱtoȱaccessȱtheȱSettingsȱmenu.ȱ
FromȱtheȱSettingsȱmenuȱselectȱ[4]ȱtoȱaccessȱtheȱStandardȱoption.ȱȱ
Defaultȱoption.ȱ
SelectȱENȱ50131.ȱOnceȱselected,ȱtheȱfollowingȱchangesȱwillȱoccurȱinȱtheȱAgilityȱsoftware:ȱ
Report Codes
Feature
EN 50131 Compliance
Timersȱȱȱ
ȱ
ȱ
PhoneȱLineȱcutȱdelayȱ
Immediateȱ(0ȱminutes)ȱ
EntryȱDelayȱ
45ȱsecondsȱ(maximumȱallowed)ȱ
ACȱDelayȱ
Immediateȱ(0ȱminutes)ȱ
JammingȱTimeȱ
0ȱminutesȱ
RXȱSupervisionȱ
2ȱhoursȱ
SystemȱControlsȱȱȱ
ȱ
ȱ
QuickȱSetȱ
SetȱtoȱNOȱ
ȱ
FalseȱCodeȱFaultȱ
SetȱtoȱYesȱ
ȱ
ForcedȱSettingȱ
SetȱtoȱNOȱ
ȱ
AuthorizeȱEngineerȱ
SetȱtoȱYESȱ
ȱ
OverrideȱFaultȱ
SetȱtoȱNOȱ
ȱ
RestoreȱAlarmȱ
SetȱtoȱYESȱ
ȱ
MandatoryȱEventȱLogȱ
SetȱtoȱYESȱ
ȱ
RestoreȱFaultȱ
SetȱtoȱYESȱ
ȱ
ExitȱAlarmȱ
SetȱtoȱNOȱ
ȱ
20ȱMinutesȱSignalȱ
SetȱtoȱYESȱ
ȱ
EntryȱDelayedȱAlarmȱ
SetȱtoȱNOȱ
ȱ
Attenuationȱ
SetȱtoȱYESȱ
ȱ
ȱ
Page D-2
AgilityȱEngineerȱManualȱ
ȱ
Appendix E Installer Programming Maps
1)ȱProgrammingȱ
2)ȱTestingȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱActivitiesȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
4)ȱFollowȱMeȱ
ȱ
ȱ
5)ȱClockȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
6)ȱEventȱLogȱ
7)ȱMacroȱ
SeeȱprogrammingȱmenuȱonȱpageȱEȬ2.ȱ
ȱ
ȱ
1)ȱMainȱUnitȱ
ȱ
ȱ
1)ȱNoiseȱLevelȱ
ȱ
2)ȱSounderȱ
ȱ
3)ȱSpeakerȱ
2)ȱZoneȱ
ȱ
ȱ
1)ȱCommunicationȱTestȱ
ȱ
2)ȱBatteryȱTestȱ
3)ȱKeyfobȱ
ȱ
ȱ
1)ȱCommunicationȱTestȱ
ȱ
2)ȱBatteryȱTestȱ
ȱ
3)ȱVersionȱ
4)ȱKeypadȱ
ȱ
ȱ
1)ȱCommunicationȱTestȱ
ȱ
2)ȱBatteryȱTestȱ
ȱ
3)ȱVersionȱ
5)ȱSounderȱ
ȱ
ȱ
1)ȱCommunicationȱTestȱ
ȱ
2)ȱBatteryȱTestȱ
ȱ
3)ȱSoundȱTestȱ
6)ȱGSMȱ
ȱ
ȱ
1)ȱSignalȱ
ȱ
2)ȱVersionȱ
ȱ
3)ȱIMEIȱ
7)ȱIPȱUnitȱ
ȱ
ȱ
1)ȱIPȱAddressȱ
ȱ
2)ȱVersionȱ
ȱ
3)ȱMACȱaddressȱ
8)ȱI/OȱModuleȱ
ȱ
ȱ
1)ȱCommunicationȱTestȱ
ȱ
2)ȱBatteryȱTestȱ
ȱ
3)ȱVersionȱ
ȱ
ȱ
1)ȱMainȱBuzzerȱOn/Offȱȱ
ȱ
2)ȱKPȱSleepȱTimeȱ
ȱ
3)ȱSounderȱTMPȱMuteȱ
ȱ
4)ȱAvoidȱReportȱProgȱ
ȱ
5)ȱOmitȱBoxȱTamperȱ
ȱ
6)ȱEngineerȱResetȱ
ȱ
7)ȱCSȱConnectȱ
ȱ
8)ȱFirmwareȱUpdateȱ
ȱ
ȱ
ȱ
1)ȱDefineȱ
ȱ
2)ȱTestȱFollowȱMeȱ
ȱ
ȱ
ȱ
1)ȱTimeȱandȱDateȱ
ȱ
2)ȱSchedulerȱȱ
ȱ
3)ȱAuto.ȱClockȱ
ȱ
ȱ
1)ȱServerȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱHostȱ
ȱ
3)ȱPortȱ
ȱ
4)ȱTimeȱZoneȱ
ȱ
ȱ
ȱ
ȱ
Page E-1
ȱ
ȱ
ȱ
4)ȱBatteryȱ
5)ȱVersionȱ
6)ȱSerialȱNumberȱ
ȱ
3)ȱWalkȱTestȱ
4)ȱVersionȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
4)ȱNoiseȱLevelȱ
5)ȱVersionȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Daytimeȱ
NTPȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
AgilityȱEngineerȱManualȱ
ȱ
ȱ
ȱ
ȱ
InstallerȱProgrammingȱmenu:ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱSystemȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱTimersȱ
ȱ
ȱ
ȱ
ȱ
1)ȱEx/EnȱDelayȱ1ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱEntryȱDelayȱ1ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱExitȱDelayȱ1ȱ
ȱ
ȱ
ȱ
2)ȱEx/EnȱDelayȱ2ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱEntryȱDelayȱ2ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱExitȱDelayȱ2ȱ
ȱ
ȱ
ȱ
3)ȱBellȱTimeoutȱ
ȱ
ȱ
ȱ
ȱ
4)ȱBellȱDelayȱ
ȱ
ȱ
ȱ
ȱ
5)ȱACȱOffȱDelayȱ
ȱ
ȱ
ȱ
ȱ
6)ȱJammingȱTimeȱ
ȱ
ȱ
ȱ
ȱ
7)ȱRXȱSuperviseȱ
ȱ
ȱ
ȱ
ȱ
8)ȱTXȱSuperviseȱ
ȱ
ȱ
ȱ
ȱ
9)ȱRedialȱWaitȱ
ȱ
ȱ
ȱ
ȱ
0)ȱMoreȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱSwingerȱlimitȱ
ȱ
ȱ
ȱ
ȱ
2)ȱNoȱActivityȱ
ȱ
ȱ
ȱ
ȱ
3)ȱLastȱExitȱSoundȱ
ȱ
ȱ
2)ȱControlsȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱBasicȱȱ
ȱ
ȱ
ȱ
ȱ
ȱ
QuickȱSetȱ
ȱ
ȱ
ȱ
ȱ
AllowȱOmitȱ
ȱ
ȱ
ȱ
ȱ
QuickȱStatusȱ
ȱ
ȱ
ȱ
ȱ
FalseȱCodeȱFaultȱ
ȱ
ȱ
ȱ
ȱ
SounderȱSquawkȱ
ȱ
ȱ
ȱ
ȱ
AudibleȱPanicȱ
ȱ
ȱ
ȱ
ȱ
BuzzerȱÆȱBellȱ
ȱ
ȱ
ȱ
ȱ
AudibleȱJammingȱ
ȱ
ȱ
ȱ
ȱ
ExitȱPartȱSetȱBeepȱ
ȱ
ȱ
ȱ
ȱ
ForcedȱSettingȱ
ȱ
SetȱPreȬWarningȱ
ȱ
ȱ
ȱ
ȱ
DefaultȱEnableȱ
ȱ
ȱ
ȱ
ȱ
MainȱBut:ȱStatus/Talkȱ
ȱ
ȱ
ȱ
ȱ
QuickȱLearnȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱAdvancedȱȱ
ȱ
ȱ
ȱ
ȱ
Areaȱ
ȱ
ȱ
ȱ
ȱ
ȱ
GlobalȱFollowerȱ
ȱ
ȱ
ȱ
Summer/Winterȱ
ȱ
ȱ
ȱ
ȱ
24ȱHourȱOmitȱ
ȱ
ȱ
ȱ
ȱ
TamperȱResetȱ
ȱ
ȱ
ȱ
ȱ
EngineerȱResetȱ
ȱ
ȱ
ȱ
ȱ
EngineerȱTamperȱ
ȱ
ȱ
ȱ
ȱ
LowȱBatteryȱSetȱ
ȱ
ȱ
ȱ
ȱ
SounderȱPreȬalarmȱ
ȱ
ȱ
ȱ
ȱ
Bellȱ30/10ȱ
ȱ
ȱ
ȱ
ȱ
FireȱPatternȱ
ȱ
ȱ
Page E-2
AgilityȱEngineerȱManualȱ
ȱ
ȱ
ȱ
ȱ
IMQȱ
ȱ
ȱ
ȱ
DisableȱIncomingȱCallȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ARCȱEnableȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱCommunicationȱ
ȱ
ȱ
ȱ
ȱ
4)ȱENȱ50131ȱ
ȱ
ȱ
ȱ
ConfigurationȱSoftwareȱEnableȱ
FMȱEnableȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
AuthorizeȱEngineerȱ
ȱ
ȱ
ȱ
OverrideȱFaultȱ
ȱ
ȱ
ȱ
RestoreȱAlarmȱ
ȱ
ȱ
ȱ
ȱ
MandatoryȱEventsȱ
ȱ
ȱ
ȱ
ȱ
RestoreȱFaultȱ
ȱ
ȱ
ȱ
ȱ
ExitȱAlarmȱ
ȱ
ȱ
ȱ
ȱ
EntryȱAlarmȱ
ȱ
ȱ
ȱ
ȱ
20ȱMinutesȱSignalȱ
ȱ
ȱ
ȱ
ȱ
Attenuationȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
5)ȱDD243ȱȱ
ȱ
ȱ
OmitȱExit/Entryȱ
ȱ
ȱ
ȱ
ȱ
EntryȱDisableȱ
ȱ
ȱ
ȱ
ȱ
RouteȱDisableȱ
ȱ
ȱ
ȱ
ȱ
EngineerȱConfirmationȱ
ȱ
ȱ
ȱ
ȱ
KeyswitchȱLockȱ
ȱ
ȱ
ȱ
ȱ
EntryȱUnsetȱ
ȱ
ȱ
ȱ
6)ȱCPȬ01ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ExitȱRestartȱ
ȱ
ȱ
ȱ
ȱ
AutoȱPartȱSetȱ
ȱ
ȱ
ȱ
ȱ
ExitȱErrorȱ
ȱ
ȱ
ȱ
ȱ
3ȱMinutesȱOmitȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱSystemȱ
ȱ
ȱ
ȱ
ȱ
2)ȱPartitionȱ1ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱPartitionȱ2ȱ
ȱ
ȱ
ȱ
ȱ
4)ȱPartitionȱ3ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱTamperȱSoundȱ
ȱ
ȱ
ȱ
ȱ
Silentȱ
ȱ
ȱ
3)ȱLabelsȱ
4)ȱSoundsȱ
ȱ
ȱ
ȱ
ȱ
Bellȱ
ȱ
ȱ
ȱ
ȱ
Buzzerȱ(main)ȱ
ȱ
ȱ
ȱ
ȱ
Bellȱ+ȱBuzzerȱ
ȱ
ȱ
ȱ
ȱ
Bell/Setȱ+ȱBuzzer/Unsetȱ
ȱ
ȱ
ȱ
ȱ
Bell/Setȱ+ȱSil/Unsetȱ
ȱ
ȱ
ȱ
ȱ
2)ȱLocalȱAlarmȱ
ȱ
ȱ
ȱ
3)ȱLocalȱSquawkȱ
ȱ
ȱ
ȱ
ȱ
4)ȱEx/EnȱBeepsȱȱ
ȱ
ȱ
ȱ
ȱ
5)ȱSpeakerȱVolumeȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
5)ȱSettingsȱ
ȱ
1)ȱDefaultȱPanelȱ
ȱ
ȱ
ȱ
2)ȱEraseȱWLȱDeviceȱ
ȱ
ȱ
ȱ
ȱ
3)ȱLanguageȱ
ȱ
ȱ
ȱ
Page E-3
AgilityȱEngineerȱManualȱ
ȱ
ȱ
4)ȱStandardȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ENȱ50131ȱ
ȱ
ȱ
ȱ
ȱ
DD243ȱ
ȱ
ȱ
ȱ
ȱ
CPȬ01ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱServiceȱNameȱ
ȱ
ȱ
ȱ
2)ȱPhoneȱ
ȱ
6)ȱServiceȱInfoȱ
ȱ
ȱ
7)ȱFirmwareȱUpdateȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱServerȱIPȱ
ȱ
ȱ
ȱ
ȱ
2)ȱServerȱPortȱ
ȱ
ȱ
ȱ
3)ȱFileȱPathȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱRFȱAllocationȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱByȱSerialȱcodeȱ
ȱ
ȱ
ȱ
3)ȱZoneȱAllocationȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱRadioȱDevicesȱ
1)ȱAllocationȱ
ȱ
ȱ
ȱ
2)ȱModificationȱ
ȱ
1)ȱZonesȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱParametersȱ
ȱ
ȱ
ȱ
ȱ
1)ȱLabelȱ
ȱ
2)ȱSerialȱNo.ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱPartitionȱ
ȱ
ȱ
ȱ
ȱ
4)ȱTypeȱ
ȱ
ȱ
ȱ
ȱ
5)ȱSoundȱ
ȱ
ȱ
ȱ
ȱ
6)ȱAdvancedȱȱ
ȱ
ȱ
ȱ
ȱ
1)ȱChimeȱ
ȱ
ȱ
ȱ
2)ȱControlsȱ
ȱ
ȱ
ȱ
Supervisionȱ
ȱ
ȱ
ȱ
ForcedȱSettingȱȱ
ȱ
ȱ
ȱ
NoȱActivityȱ
ȱ
ȱ
ȱ
AbortȱAlarmȱ
ȱ
ȱ
ȱ
LEDȱEnableȱȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱSoakȱTestȱ
ȱ
ȱ
ȱ
ȱ
4)ȱZoneȱPairingȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱParametersȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱKeyfobsȱ
ȱ
ȱ
ȱ
ȱ
2)ȱAlarmȱConfirmationȱ
3)ȱDetectionȱModeȱ
4)ȱSensitivityȱȱ
ȱ
ȱ
1)ȱConfirmȱPartitionȱ
ȱ
2)ȱConfirmȱZonesȱ
ȱ
ȱ
ȱ
1ȬWayȱKeyfobȱ
2ȬWayȱKeyfobȱ
1)ȱLabelȱ
1)ȱLabelȱ
ȱ
ȱ
ȱ
2)ȱSerialȱNo.ȱ
2)ȱSerialȱNo.ȱ
ȱ
ȱ
ȱ
3)ȱPartitionȱ
3)ȱPartitionȱ
ȱ
ȱ
ȱ
4)ȱButtonȱ1ȱ
4)ȱPINȱCodeȱ
ȱ
ȱ
ȱ
5)ȱButtonȱ2ȱ
5)ȱPanicȱEnableȱ
ȱ
ȱ
ȱ
6)ȱButtonȱ3ȱ
6)ȱPOȱButtonȱ1ȱ
ȱ
ȱ
ȱ
7)ȱButtonȱ4ȱ
7)ȱPOȱButtonȱ2ȱ
ȱ
ȱ
ȱ
ȱ
8)ȱPOȱButtonȱ3ȱ
Page E-4
AgilityȱEngineerȱManualȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
InstantȱF.ȱSetȱ
ȱ
ȱ
ȱ
ȱ
InstantȱP.ȱSetȱ
ȱ
ȱ
ȱ
ȱ
Unsetȱ+ȱCodeȱ
ȱ
3)ȱParentȱControlȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱParametersȱ
ȱ
1)ȱLabelȱ
ȱ
2)ȱSerialȱNo.ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱKeypadsȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱControlsȱ
ȱ
3)ȱEmergencyȱKeysȱ
ȱ
ȱ
ȱ
4)ȱFunctionȱKeyȱ
ȱ
ȱ
ȱ
ȱ
5)ȱOutputȱControlȱ
ȱ
ȱ
ȱ
2)ȱControlsȱ
ȱ
ȱ
ȱ
ȱ
ȱ
RFȱWakeȬupȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
4)ȱSoundersȱ
ȱ
1)ȱLabelȱ
ȱ
ȱ
ȱ
ȱ
2)ȱSerialȱNumberȱ
ȱ
ȱ
ȱ
ȱ
3)ȱPartitionȱ
ȱ
ȱ
ȱ
ȱ
4)ȱSupervisionȱ
ȱ
ȱ
ȱ
ȱ
5)ȱVolumeȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱAlarmȱ
ȱ
ȱ
ȱ
ȱ
2)ȱSquawkȱ
ȱ
ȱ
ȱ
ȱ
3)ȱExitȱEntryȱȱ
ȱ
ȱ
ȱ
6)ȱStrobeȱ(Ext.l)ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱStrobeȱCtrlȱȱ
ȱ
ȱ
ȱ
ȱ
2)ȱStrobeȱBlinkȱ
ȱ
ȱ
ȱ
ȱ
3)ȱStrobeȱatȱSetȱȱ
ȱ
ȱ
5)ȱI/OȱModulesȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱWiredȱZonesȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱLabelȱ
ȱ
2)ȱPartitionȱ
ȱ
ȱ
ȱ
ȱ
3)ȱTypeȱ
ȱ
ȱ
ȱ
ȱ
4)ȱSoundȱ
ȱ
ȱ
ȱ
ȱ
5)ȱAdvancedȱȱ
ȱ
ȱ
ȱ
ȱ
1)ȱChimeȱ
ȱ
ȱ
ȱ
2)ȱControlȱ
ȱ
ȱ
ȱ
3)ȱTerminationȱ
ȱ
ȱ
ȱ
4)ȱLoopȱResponseȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱOutputsȱ
ȱ
5)ȱDetectionȱModeȱ
ȱ
ȱ
1)ȱLabelȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱTypeȱ
ȱ
ȱ
ȱ
3)ȱPatternȱ
ȱ
ȱ
ȱ
ȱ
4)ȱPulseȱLengthȱ
ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱXȬ10ȱOutputsȱ
ȱ
ȱ
ȱ
1)ȱLabelȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱTypeȱ
ȱ
ȱ
ȱ
3)ȱPatternȱ
ȱ
ȱ
ȱ
ȱ
4)ȱPulseȱLengthȱ
ȱ
ȱ
ȱ
ȱ
ȱ
4)ȱParametersȱ
Page E-5
AgilityȱEngineerȱManualȱ
ȱ
ȱ
ȱ
ȱ
1)ȱSerialȱNo.ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱControlȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱSupervisionȱ
ȱ
ȱ
ȱ
ȱ
2)ȱQuickȱPO/X10ȱ
ȱ
ȱ
ȱ
3)ȱX10ȱHouseȱIDȱ
ȱ
ȱ
ȱ
ȱ
4)ȱPOȱDTMFȱControlȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱLabelȱ
ȱ
ȱ
ȱ
ȱ
2)ȱPartitionȱ
ȱ
ȱ
ȱ
ȱ
3)ȱAuthorityȱȱ
ȱ
ȱ
ȱ
3)ȱIdentificationȱ
3)ȱCodesȱ
1)ȱUserȱ
ȱ
ȱ
ȱ
Userȱ
ȱ
ȱ
ȱ
ȱ
Cleanerȱ
ȱ
ȱ
ȱ
ȱ
SetȱOnlyȱ
ȱ
ȱ
ȱ
ȱ
Duressȱ
ȱ
ȱ
2)ȱGrandȱMasterȱ
ȱ
ȱ
ȱ
ȱ
3)ȱEngineerȱ
ȱ
ȱ
ȱ
ȱ
4)ȱSubȬEngineerȱ
ȱ
ȱ
ȱ
ȱ
5)ȱCodeȱLengthȱ
ȱ
ȱ
ȱ
ȱ
ȱ
4ȱDigitsȱ
ȱ
ȱ
ȱ
ȱ
6ȱDigitsȱ
ȱ
ȱ
ȱ
6)ȱDTMFȱCodeȱ
ȱ
ȱ
ȱ
ȱ
7)ȱParentȱControlȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
4)ȱCommunicationȱ
1)ȱMethodȱ
ȱ
1)ȱPSTNȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱTimersȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱPSTNȱLostȱDelayȱ
ȱ
ȱ
ȱ
2)ȱWaitȱforȱDialȱToneȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
AlarmȱLineȱCutȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱControlsȱ
ȱ
3)ȱParametersȱ
ȱ
AnswerȱMachineȱOverrideȱ
ȱ
ȱ
1)ȱRingsȱtoȱAnswerȱ
ȱ
ȱ
ȱ
ȱ
2)ȱAreaȱCodeȱ
ȱ
ȱ
ȱ
ȱ
3)ȱPBXȱPrefixȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱGSMȱLostȱ
2)ȱSIMȱExpireȱ
3)ȱARCȱPollingȱ
ȱ
1)ȱAPNȱCodeȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱAPNȱUserȱNameȱ
3)ȱAPNȱPasswordȱ
ȱ
1)ȱMailȱHostȱ
2)ȱSMTPȱPortȱ
3)ȱEȬmailȱAddressȱ
4)ȱSMTPȱUserȱNameȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
5)ȱSMTPȱPasswordȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱGSMȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱTimersȱ
ȱ
ȱ
ȱ
2)ȱGPRSȱ
ȱ
ȱ
ȱ
3)ȱEmailȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Page E-6
AgilityȱEngineerȱManualȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱGSMȱRSSIȱ
ȱ
ȱ
ȱ
ȱ
4)ȱSIMȱNumberȱ
ȱ
ȱ
ȱ
6)ȱPreȬPaidȱSIMȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱGetȱCreditȱbyȱ
ȱ
ȱ
ȱ
ȱ
2)SMSȱReceiveȱPhoneȱ
4)ȱControlsȱ
ȱ
5)ȱParametersȱ
ȱ
ȱ
ȱ
CallerȱIDȱ
ȱ
ȱ
ȱ
1)ȱSIMȱPINȱCodeȱ
ȱ
2)ȱSMSȱCenterȱPhoneȱ
ȱ
3)ȱIPȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱIPȱConfigurationȱ
ȱ
1)ȱObtainȱAutoȱIPȱ
ȱ
ȱ
ȱ
ȱ
2)ȱPanelȱIPȱ
ȱ
ȱ
ȱ
ȱ
3)ȱSubnetȱMaskȱ
ȱ
ȱ
ȱ
ȱ
4)ȱGatewayȱ
ȱ
ȱ
ȱ
ȱ
5)ȱDNSȱPrimaryȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱEȬmailȱ
6)ȱDNSȱSecondaryȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱMailȱHostȱ
ȱ
ȱ
ȱ
ȱ
2)ȱSMTPȱPortȱ
ȱ
ȱ
ȱ
ȱ
3)ȱEȬmailȱAddressȱ
ȱ
ȱ
ȱ
ȱ
4)ȱSMTPȱNameȱ
ȱ
ȱ
ȱ
ȱ
5)ȱSMTPȱPasswordȱ
ȱ
ȱ
ȱ
3)ȱHostȱNameȱ
ȱ
ȱ
ȱ
ȱ
4)ȱARCȱPollingȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱPrimaryȱ
ȱ
ȱ
ȱ
ȱ
2)ȱSecondaryȱ
ȱ
ȱ
ȱ
ȱ
3)ȱBackupȱ
ȱ
ȱ
5)ȱControlsȱ
ȱ
ȱ
ȱ
ȱ
DisableȱIPȱ
ȱ
ȱ
ȱ
2)ȱAlarmȱReceivingȱȱ
ȱȱȱȱȱȱȱȱCenterȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱReportȱTypeȱ
ȱ
ȱ
ȱ
ȱ
Voiceȱ
ȱ
ȱ
ȱ
ȱ
SMSȱ
ȱ
ȱ
ȱ
ȱ
IPȱ
ȱ
ȱ
ȱ
2)ȱAccountsȱ
ȱ
ȱ
ȱ
ȱ
3)ȱCommȱFormatȱ
ȱ
ȱ
ȱ
ȱ
ContactȱIDȱ
ȱ
ȱ
SIAȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
4)ȱControlsȱ
ȱ
ȱ
Handshakeȱ
ȱ
ȱ
ȱ
ȱ
KissȬOffȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱARCȱRetriesȱ
ȱ
ȱ
2)ȱAlarmȱRestoreȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
5)ȱParametersȱ
ȱ
ȱ
6)ȱARCȱTimersȱ
ȱ
1)ȱPeriodicȱTestȱ
ȱ
ȱ
ȱ
2)ȱAbortȱAlarmȱ
ȱ
ȱ
ȱ
ȱ
3)ȱCancelȱDelayȱ
ȱ
ȱ
Page E-7
AgilityȱEngineerȱManualȱ
ȱ
ȱ
ȱ
4)ȱListenȱInȱ
ȱ
ȱ
ȱ
5)ȱConfirmationȱ
ȱ
ȱ
ȱ
ȱ
6)ȱNoȱSetȱ
ȱ
ȱ
ȱ
ȱ
7)ȱReportȱSplitȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱARCȱSet/Unsetȱ
ȱ
ȱ
ȱ
ȱ
2)ȱARCȱUrgentȱ
ȱ
ȱ
ȱ
ȱ
3)ȱARCȱNonȱUrgentȱ
ȱ
ȱ
ȱ
8)ȱReportȱCodesȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱEditȱCodesȱ
ȱ
ȱ
ȱ
ȱ
2)ȱDeleteȱAllȱ
ȱ
ȱ
3)ȱConfigurationȱs/wȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱSecurityȱ
ȱ
ȱ
ȱ
ȱ
1)ȱAccessȱcodeȱ
ȱ
ȱ
ȱ
ȱ
2)ȱRemoteȱIDȱ
ȱ
ȱ
ȱ
ȱ
3)ȱARCȱLockȱ
ȱ
ȱ
ȱ
ȱ
ȱ
4)ȱFollowȬMeȱ
ȱ
ȱ
2)ȱCallȱBackȱ
3)ȱConfigȱSWȱPortȱ(IPȱ
Gateway)ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱDefineȱFMȱ
ȱ
ȱ
ȱ
ȱ
1)ȱReportȱtypeȱ
ȱ
ȱ
ȱ
Voiceȱȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
SMSȱ
ȱ
ȱ
ȱ
ȱ
Emailȱ
ȱ
ȱ
ȱ
ȱ
2)ȱEventsȱ
ȱ
ȱ
ȱ
3)ȱRestoreȱeventsȱ
ȱ
ȱ
ȱ
ȱ
4)ȱRemoteȱcontrolȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Remoteȱlistenȱ
ȱ
ȱ
ȱ
Remoteȱprogramȱ
ȱ
ȱ
ȱ
5)ȱPartitionȱ
ȱ
ȱ
ȱ
ȱ
ȱ
UnsetȱstopȱFMȱ
ȱ
ȱ
3)ȱParametersȱ
ȱ
ȱ
ȱ
ȱ
2)ȱControlsȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱFMȱRetriesȱ
ȱ
ȱ
ȱ
ȱ
2)ȱVoiceȱMesgȱReccur.ȱ
ȱ
ȱ
ȱ
ȱ
3)ȱPeriodicȱtestȱ
ȱ
ȱ
5)ȱAudioȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
1)ȱAssignȱMessageȱ
ȱ
1)ȱZoneȱ
ȱ
ȱ
ȱ
2)ȱPartitionȱ
ȱ
ȱ
ȱ
ȱ
3)ȱOutputȱ
ȱ
ȱ
ȱ
ȱ
4)ȱX10ȱoutputȱ
ȱ
ȱ
ȱ
ȱ
5)ȱMacroȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
2)ȱLocalȱMessageȱ
0)ȱExitȱ
Page E-8
Notes
ȱ
Notes
ȱ
RISCO Group Limited Warranty
RISCOȱGroupȱandȱitsȱsubsidiariesȱandȱaffiliatesȱ(ȈSellerȈ)ȱwarrantsȱitsȱproductsȱtoȱbeȱfreeȱ
fromȱdefectsȱinȱmaterialsȱandȱworkmanshipȱunderȱnormalȱuseȱforȱ24ȱmonthsȱfromȱtheȱdateȱ
ofȱproduction.ȱBecauseȱSellerȱdoesȱnotȱinstallȱorȱconnectȱtheȱproductȱandȱbecauseȱtheȱ
productȱmayȱbeȱusedȱinȱconjunctionȱwithȱproductsȱnotȱmanufacturedȱbyȱtheȱSeller,ȱSellerȱ
cannotȱguaranteeȱtheȱperformanceȱofȱtheȱsecurityȱsystemȱwhichȱusesȱthisȱproduct.ȱSellerȇsȱ
obligationȱandȱliabilityȱunderȱthisȱwarrantyȱisȱexpresslyȱlimitedȱtoȱrepairingȱandȱreplacing,ȱ
atȱSellerȇsȱoption,ȱwithinȱaȱreasonableȱtimeȱafterȱtheȱdateȱofȱdelivery,ȱanyȱproductȱnotȱ
meetingȱtheȱspecifications.ȱSellerȱmakesȱnoȱotherȱwarranty,ȱexpressedȱorȱimplied,ȱandȱ
makesȱnoȱwarrantyȱofȱmerchantabilityȱorȱofȱfitnessȱforȱanyȱparticularȱpurpose.ȱ
Inȱnoȱcaseȱshallȱsellerȱbeȱliableȱforȱanyȱconsequentialȱorȱincidentalȱdamagesȱforȱbreachȱofȱ
thisȱorȱanyȱotherȱwarranty,ȱexpressedȱorȱimplied,ȱorȱuponȱanyȱotherȱbasisȱofȱliabilityȱ
whatsoever.ȱ
Sellerȇsȱobligationȱunderȱthisȱwarrantyȱshallȱnotȱincludeȱanyȱtransportationȱchargesȱorȱcostsȱ
ofȱinstallationȱorȱanyȱliabilityȱforȱdirect,ȱindirect,ȱorȱconsequentialȱdamagesȱorȱdelay.ȱ
Sellerȱdoesȱnotȱrepresentȱthatȱitsȱproductȱmayȱnotȱbeȱcompromisedȱorȱcircumvented;ȱthatȱ
theȱproductȱwillȱpreventȱanyȱpersonalȱinjuryȱorȱpropertyȱlossȱbyȱburglary,ȱrobbery,ȱfireȱorȱ
otherwise;ȱorȱthatȱtheȱproductȱwillȱinȱallȱcasesȱprovideȱadequateȱwarningȱorȱprotection.ȱ
Buyerȱunderstandsȱthatȱaȱproperlyȱinstalledȱandȱmaintainedȱalarmȱmayȱonlyȱreduceȱtheȱriskȱ
ofȱburglary,ȱrobberyȱorȱfireȱwithoutȱwarning,ȱbutȱisȱnotȱinsuranceȱorȱaȱguarantyȱthatȱsuchȱ
eventȱwillȱnotȱoccurȱorȱthatȱthereȱwillȱbeȱnoȱpersonalȱinjuryȱorȱpropertyȱlossȱasȱaȱresultȱ
thereof.ȱ
Consequentlyȱsellerȱshallȱhaveȱnoȱliabilityȱforȱanyȱpersonalȱinjury,ȱpropertyȱdamageȱorȱlossȱ
basedȱonȱaȱclaimȱthatȱtheȱproductȱfailsȱtoȱgiveȱwarning.ȱHowever,ȱifȱsellerȱisȱheldȱliable,ȱ
whetherȱdirectlyȱorȱindirectly,ȱforȱanyȱlossȱorȱdamageȱarisingȱunderȱthisȱlimitedȱwarrantyȱorȱ
otherwise,ȱregardlessȱofȱcauseȱorȱorigin,ȱsellerȇsȱmaximumȱliabilityȱshallȱnotȱexceedȱtheȱ
purchaseȱpriceȱofȱtheȱproduct,ȱwhichȱshallȱbeȱcompleteȱandȱexclusiveȱremedyȱagainstȱseller.ȱ
NoȱemployeeȱorȱrepresentativeȱofȱSellerȱisȱauthorizedȱtoȱchangeȱthisȱwarrantyȱinȱanyȱwayȱ
orȱgrantȱanyȱotherȱwarranty.ȱ
WARNING:ȱThisȱproductȱshouldȱbeȱtestedȱatȱleastȱonceȱaȱweek.ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Contacting RISCO Group
RISCOȱGroupȱisȱcommittedȱtoȱcustomerȱserviceȱandȱproductȱsupport.ȱYouȱcanȱcontactȱusȱ
throughȱourȱwebsiteȱwww.riscogroup.comȱorȱasȱfollows:ȱ
ȱ
UnitedȱKingdomȱ
USAȱ
Tel:ȱ+44Ȭ161Ȭ655Ȭ5500
Tel:ȱ+1Ȭ631Ȭ719Ȭ4400ȱ
[email protected]ȱ
supportȬ[email protected]ȱ
Italyȱ
Tel:ȱ+39Ȭ02Ȭ66590054
[email protected]ȱ
Brazilȱ
Tel:ȱ+55Ȭ11Ȭ3661Ȭ8767ȱ
supportȬ[email protected]ȱ
Spainȱ
Tel:ȱ+34Ȭ91Ȭ490Ȭ2133
supportȬ[email protected]ȱ
Chinaȱ
Tel:ȱ+86Ȭ21Ȭ52Ȭ39Ȭ0066ȱ
supportȬ[email protected]ȱ
Franceȱ
Tel:ȱ+33Ȭ164Ȭ73Ȭ28Ȭ50
supportȬ[email protected]ȱ
Polandȱ
Tel:ȱ+48Ȭ22Ȭ500Ȭ28Ȭ40ȱ
supportȬ[email protected]ȱ
Belgiumȱ
Tel:ȱ+32Ȭ2522Ȭ7622
supportȬ[email protected]ȱ
Israelȱ
Tel:ȱ+972Ȭ3Ȭ963Ȭ7777
[email protected]ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Allȱrightsȱreserved.ȱȱ
Noȱpartȱofȱthisȱdocumentȱmayȱbeȱreproducedȱinȱanyȱformȱwithoutȱpriorȱwrittenȱ
permissionȱfromȱtheȱpublisher.ȱ
ȱ
ȱ
©ȱRISCOȱGroupȱȱȱ03/10ȱȱ
ȱȱ
ȱ
ȱ
ȱ
ȱȱȱȱȱȱȱȱȱȱȱȱȱȱ5IN1081ȱBȱ
ȱ

advertisement

Key Features

  • 32 wireless zones
  • 3 partitions
  • up to 3 bi-directional wireless keypads
  • up to 8 remote control keyfobs
  • compatible with RISCO Group’s extensive range of wireless security and safety devices
  • flexible communication options
  • easy programming
  • remote management
  • home automation capabilities

Frequently Answers and Questions

What types of devices are compatible with the Agility 2 system?
The Agility 2 system is compatible with RISCO Group’s extensive range of wireless security and safety devices, including detectors, sounders, keypads, remote controls, keyfobs, panic buttons, and fully wireless sounders.
How many partitions can I create with the Agility 2 system?
You can create up to 3 partitions with the Agility 2 system.
Can I control the system remotely?
Yes, the Agility 2 system allows for remote management through its communication options, such as GSM, GPRS, IP, and PSTN.
What are the home automation capabilities of the Agility 2 system?
The Agility 2 system includes 4 outputs via the wireless I/O expander and 16 X-10 outputs via the wireless I/O expander. These outputs can be controlled by system, partition, zone, or user events. They can also be scheduled, activated automatically, or by user command via SMS, web browser, or remote phone.

Related manuals

Download PDF

advertisement