RISCO Agility 2 security system Engineer Manual
The Agility 2 is a versatile wireless security system that offers a wide range of features and customization options. It is ideal for both residential and commercial applications and can be easily integrated with existing security systems. The Agility 2 system includes 32 wireless zones, 3 partitions, up to 3 bi-directional wireless keypads, and up to 8 remote control keyfobs. It also supports a variety of one-way and two-way wireless security and safety devices, keypads, remote controls, keyfobs, panic buttons, fully wireless sounders, and other accessories. The Agility 2 system is compatible with RISCO Group’s extensive range of wireless security and safety devices.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
ȱ Engineer Manual ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ `ȱ AgilityȱEngineerȱManual ȱ Important Notice Thisȱguideȱisȱdeliveredȱsubjectȱtoȱtheȱfollowingȱconditionsȱandȱrestrictions:ȱ ThisȱguideȱcontainsȱproprietaryȱinformationȱbelongingȱtoȱRISCOȱGroup.ȱSuchȱ informationȱisȱsuppliedȱsolelyȱforȱtheȱpurposeȱofȱassistingȱexplicitlyȱandȱproperlyȱ authorizedȱusersȱofȱtheȱsystem.ȱ Noȱpartȱofȱitsȱcontentsȱmayȱbeȱusedȱforȱanyȱotherȱpurpose,ȱdisclosedȱtoȱanyȱpersonȱ orȱfirm,ȱorȱreproducedȱbyȱanyȱmeans,ȱelectronicȱorȱmechanical,ȱwithoutȱtheȱexpressȱ priorȱwrittenȱpermissionȱofȱRISCOȱGroup.ȱ Theȱinformationȱcontainedȱhereinȱisȱforȱtheȱpurposeȱofȱillustrationȱandȱreferenceȱ only.ȱ Informationȱinȱthisȱdocumentȱisȱsubjectȱtoȱchangeȱwithoutȱnotice.ȱ Corporateȱandȱindividualȱnamesȱandȱdataȱusedȱinȱexamplesȱhereinȱbelongȱtoȱtheirȱ respectiveȱowners.ȱ Compliance Statement Hereby,ȱRISCOȱGroupȱdeclaresȱthatȱtheȱAgilityȱseriesȱofȱcentralȱunitsȱandȱaccessoriesȱareȱ designedȱtoȱcomplyȱwith:ȱ EN50131Ȭ1,ȱEN50131Ȭ3ȱGradeȱ2ȱ EN50130Ȭ5ȱEnvironmentalȱclassȱIIȱȱ EN50131Ȭ6ȱTypeȱAȱ UK:ȱDD243:2004,ȱPDȱ6662:2004,ȱACPOȱ(Police)ȱ USA:ȱFCC:ȱPartȱ15B,ȱFCCȱpartȱ68ȱȱ CANADA:ȱCSȬ03,ȱDCȬ01ȱ ȱ ȱ Allȱrightsȱreserved.ȱȱ ȱ2010ȱRISCOȱGroupȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱMarchȱ2010ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Page ii AgilityȱEngineerȱManualȱ ȱ ȱ ȱ Table of Contents CHAPTERȱ1ȱINTRODUCTION ................................................................................................1-1ȱ ARCHITECTURE ............................................................................................................................1-2ȱ MAINȱFEATURES...........................................................................................................................1-3ȱ TECHNICALȱSPECIFICATIONS........................................................................................................1-4ȱ CHAPTERȱ2ȱINSTALLINGȱTHEȱAGILITY.............................................................................2-1ȱ AGILITYȱMAINȱCOMPONENTS ......................................................................................................2-1ȱ MOUNTINGȱTHEȱAGILITY .............................................................................................................2-2ȱ Choosingȱtheȱmountingȱlocation ..............................................................................................2-2ȱ WallȱMountingȱtheȱAgility ......................................................................................................2-2ȱ ConnectingȱtheȱBackupȱBattery ...............................................................................................2-5ȱ ConnectingȱtheȱAgilityȱtoȱPowerȱSupplyȱȬȱConfigurationȱA ...................................................2-6ȱ GroundȱConnection..................................................................................................................2-6ȱ ConnectingȱtheȱAgilityȱtoȱPowerȱSupplyȱȬȱConfigurationȱB....................................................2-7ȱ CompletingȱInstallation ...........................................................................................................2-8ȱ DIPȱswitchȱsetting ...................................................................................................................2-8ȱ ConnectingȱaȱtelephoneȱlineȱtoȱtheȱAgility ...............................................................................2-9ȱ ConnectingȱaȱnetworkȱcableȱtoȱtheȱAgility .............................................................................2-10ȱ SIMȱCardȱInstallation............................................................................................................2-11ȱ ExternalȱAudioȱUnit ..............................................................................................................2-12ȱ CHAPTERȱ3ȱENGINEERȱPROGRAMMING..........................................................................3-1ȱ PROGRAMMINGȱMETHODS ...........................................................................................................3-1ȱ ConfigurationȱSoftware............................................................................................................3-1ȱ WirelessȱKeypad.......................................................................................................................3-1ȱ EngineerȱKeypad ......................................................................................................................3-2ȱ PTM:ȱDataȱStoringȱDevice ......................................................................................................3-2ȱ WIRELESSȱDEVICEȱALLOCATION ..................................................................................................3-4ȱ QuickȱAllocationȱusingȱtheȱmainȱunitȱbutton..........................................................................3-4ȱ Allocationȱusingȱtheȱkeypad .....................................................................................................3-4ȱ AllocationȱusingȱtheȱConfigurationȱSoftware ..........................................................................3-5ȱ TransmittersȱWriteȱMessageȱMethod ......................................................................................3-7ȱ DELETINGȱWIRELESSȱACCESSORIES ..............................................................................................3-7ȱ CHAPTERȱ4ȱENGINEERȱMENUS ............................................................................................4-1ȱ USINGȱTHEȱAGILITYȱKEYPADȱKEYS ...............................................................................................4-1ȱ ACCESSINGȱTHEȱENGINEERȱMENUS .............................................................................................4-2ȱ Page iii `ȱ AgilityȱEngineerȱManual ȱ PROGRAMMINGȱMENU.................................................................................................................4-2ȱ 1.ȱProgramming:ȱSystemȱMenu...............................................................................................4-2ȱ 1.1ȱTimers ...........................................................................................................................4-3ȱ 1.2ȱControls ........................................................................................................................4-5ȱ 1.3ȱLabels ..........................................................................................................................4-14ȱ 1.4ȱSounds ........................................................................................................................4-15ȱ 1.5ȱSettings........................................................................................................................4-16ȱ 1.6ȱServiceȱInformation...................................................................................................4-17ȱ 1.7ȱFirmwareȱUpdate ......................................................................................................4-17ȱ 2.ȱProgramming:ȱRadioȱDevicesȱMenu..................................................................................4-18ȱ 2.1ȱAllocation ...................................................................................................................4-18ȱ 2.2ȱModification...............................................................................................................4-18ȱ 2.3ȱIdentification ..............................................................................................................4-41ȱ 3.ȱProgramming:ȱCodesȱMenu ...............................................................................................4-42ȱ 3.1ȱUser .............................................................................................................................4-42ȱ 3.2ȱGrandȱMaster .............................................................................................................4-43ȱ 3.3ȱEngineer......................................................................................................................4-43ȱ 3.4ȱSubȬEngineer..............................................................................................................4-43ȱ 3.5ȱCodeȱLength...............................................................................................................4-44ȱ 3.6ȱDTMFȱCode................................................................................................................4-44ȱ 3.7ȱParentȱControl............................................................................................................4-44ȱ 4.ȱProgramming:ȱCommunicationȱMenu...............................................................................4-45ȱ 4.1ȱMethod........................................................................................................................4-45ȱ 4.2ȱAlarmȱReceivingȱCenter ...........................................................................................4-53ȱ 4.3ȱConfigurationȱSoftware ............................................................................................4-59ȱ 4.4ȱFollowȬMe ..................................................................................................................4-61ȱ 5.ȱProgramming:ȱAudioȱMessagesȱMenu ..............................................................................4-67ȱ 5.1ȱAssignȱMessage .........................................................................................................4-67ȱ 5.2ȱLocalȱMessage ............................................................................................................4-67ȱ TESTINGȱMENU ...........................................................................................................................4-69ȱ 1.ȱMainȱUnit ..........................................................................................................................4-69ȱ 2.ȱZone ...................................................................................................................................4-70ȱ 3.ȱRemoteȱControlȱ(Keyfob)....................................................................................................4-70ȱ 4.ȱKeypad................................................................................................................................4-71ȱ 5.ȱSounder ..............................................................................................................................4-71ȱ 6.ȱGSM...................................................................................................................................4-72ȱ 7.ȱIPȱUnit ...............................................................................................................................4-72ȱ 8.ȱPOȱUnit .............................................................................................................................4-73ȱ ACTIVITIESȱMENU ......................................................................................................................4-74ȱ FOLLOWȱMEȱMENU ....................................................................................................................4-75ȱ Page iv AgilityȱEngineerȱManualȱ ȱ ȱ CLOCKȱMENU ............................................................................................................................4-75ȱ EVENTȱLOGȱMENU .....................................................................................................................4-76ȱ MACROȱMENU ...........................................................................................................................4-76ȱ ProgrammingȱMacroȱKeys.....................................................................................................4-76ȱ ActivatingȱaȱMacro ................................................................................................................4-77ȱ APPENDIXȱAȱREPORTȱCODES...............................................................................................AȬ1ȱ APPENDIXȱBȱENGINEERȱEVENTȱLOGȱMESSAGES ......................................................... BȬ1ȱ APPENDIXȱCȱLIBRARYȱVOICEȱMESSAGES .......................................................................CȬ1ȱ APPENDIXȱDȱENȱ50131ȱCOMPLIANCE ............................................................................... DȬ1ȱ APPENDIXȱEȱINSTALLERȱPROGRAMMINGȱMAPS ........................................................ EȬ1ȱ UKȱ UKUKUKUKUKUKUKUK Page v AgilityȱEngineerȱManualȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ ȱ Chapter 1 Introduction TheȱAgilityȱisȱaȱFlexibleȱWirelessȱSecurityȱSolutionȱthatȱincorporatesȱstateȬofȬtheȬartȱ wirelessȱandȱcommunicationȱtechnology.ȱȱAgilityȱisȱidealȱforȱinstallationȱinȱanyȱhomeȱorȱ officeȱenvironmentȱandȱsupportsȱRISCOȱGroup’sȱextensiveȱrangeȱofȱoneȬwayȱandȱtwoȬwayȱ wirelessȱsecurityȱandȱsafetyȱdevices,ȱkeypads,ȱremoteȱcontrols,ȱkeyfobs,ȱpanicȱbuttons,ȱ fullyȱwirelessȱsoundersȱandȱotherȱaccessories.ȱ MainȱBenefits:ȱ FlexibleȱPlugȬinȱCommunicationȱȱ IPȱModuleȱ GSM/GPRSȱModuleȱ FastȱPSTNȱModuleȱ Useȱanyȱsingleȱmodule,ȱanyȱcombinationȱorȱallȱthreeȱmodulesȱforȱbackup,ȱorȱnoȱ communicationȱforȱaudibleȱonlyȱinstallationsȱ 2ȬWayȱWirelessȱKeypadȱwithȱfullȱprogrammingȱcapabilityȱ 2ȬWayȱ8ȱbuttonȱWirelessȱRemoteȱControlȱwithȱcodeȱprotection,ȱkeyȬlockȱandȱ systemȱstatusȱrequestȱandȱindicationȱ 2Ȭwayȱvoiceȱcommunicationȱ EasyȱenrollingȱofȱWirelessȱDevicesȱwithoutȱaȱkeypadȱ RemoteȱenrollingȱaccordingȱtoȱDeviceȱIDȱ Combineȱone–wayȱorȱtwoȬwayȱtransmittersȱinȱtheȱsameȱsystemȱ Flashȱmemoryȱforȱeasyȱfirmwareȱupgradeȱȱ Simpleȱphysicalȱinstallationȱwithȱwallȱbracketsȱ Separateȱmainȱpanel,ȱcanȱbeȱhiddenȱforȱhigherȱsecurityȱ ProgramȱTransferȱModuleȱ(PTM)ȱforȱprogramȱbackupȱ Simplifiedȱmenuȱlogicȱ(onlyȱmenusȱofȱinstalledȱdevicesȱareȱdisplayed,ȱonlyȱ menusȱaccordingȱtoȱtheȱauthorizationȱcodeȱareȱdisplayed)ȱȱ MainȱFeatures:ȱ 32ȱwirelessȱzonesȱ 3ȱpartitionsȱ Upȱtoȱ3ȱbiȬdirectionalȱwirelessȱkeypadsȱ Upȱtoȱ8ȱRemoteȱControlȱkeyfobsȱ(combinationȱofȱ8ȱorȱ4ȱbutton)ȱorȱoneȱwayȱ Input/Outputȱmodule:ȱ 2ȬwayȱwirelessȱcommunicationȱtoȱtheȱAgilityȱ Localȱtransformerȱwithȱrechargeableȱbackupȱbatteriesȱ 4ȱwiredȱzonesȱwithȱselectableȱEOLȱresistanceȱ&ȱ4ȱoutputsȱ(2x3Aȱrelayȱandȱ2x500mA)ȱ IncludesȱXȬ10ȱconnectionȱȱ 32ȱuserȱcodesȱ 250ȱeventȱlogȱ UsesȱregularȱSealedȱLeadȱAcidȱBatteryȱ6Vȱ3.2ȱAh.ȱȱ Page 1-1 AgilityȱEngineerȱManualȱ ȱ Architecture TheȱfollowingȱdiagramȱprovidesȱanȱoverviewȱofȱtheȱAgilityȇsȱarchitectureȱandȱcapabilities.ȱ ExamineȱtheȱfigureȱbeforeȱbeginningȱwithȱyourȱAgilityȱinstallationȱtoȱobtainȱanȱoverallȱ pictureȱofȱtheȱfullȱextentȱofȱtheȱAgilityȱsystemȱcapabilities.ȱ Note:ȱTheȱwebȱbrowserȱfeatureȱwillȱbeȱavailableȱforȱuserȱmonitoringȱinȱfutureȱversionsȱofȱAgility.ȱ Page 1-2 AgilityȱEngineerȱManualȱ ȱ ȱ Main Features TheȱfollowingȱillustrationȱdescribesȱtheȱmainȱfeaturesȱofȱtheȱAgility:ȱ Detectorsȱ x 32ȱWirelessȱzones:ȱȱ x 4ȱWiredȱzonesȱviaȱ optionalȱWirelessȱI/Oȱ Expanderȱ x Totalȱzones:ȱ36ȱ x Moreȱthanȱ25ȱzoneȱ typesȱ x Fullȱzoneȱsupervisionȱȱ x 2Ȭwayȱandȱ1Ȭwayȱ detectorsȱcombinedȱonȱ theȱsameȱsystemȱ Soundersȱ x BuiltȬinȱsounderȱ x Fullyȱwirelessȱexternalȱ andȱinternalȱwirelessȱ soundersȱ x Addȱupȱtoȱ3ȱSoundersȱȱ AlarmȱReceivingȱCenterȱ x Remoteȱprogramming,ȱ diagnosticsȱandȱ communicationȱtest.ȱ x Reportȱtoȱ3ȱARC.ȱ x ReportȱthoughtȱPSTN,ȱ GSM,ȱGPRSȱorȱIP.ȱ x ARCȱpollingȱthroughȱIPȱ network.ȱ x Accountȱnumberȱforȱ eachȱARC.ȱ x Flexibleȱsplitȱreportingȱ forȱbackup.ȱ x CallȱSaveȱmodeȱforȱnonȬ urgentȱreports.ȱ x Remoteȱdeviceȱ enrollment.ȱ Communication:ȱ x Flexibleȱcommunicationȱ overȱGSM/GPRS,ȱIPȱorȱ PSTN.ȱȱ x Backupȱcapabilityȱ betweenȱtheȱ communicationȱmethods.ȱ x Supportsȱmajorȱreportingȱ formats.ȱ x Addȱonȱmoduleȱforȱeachȱ communicationȱtype.ȱ EngineerȱProgramming:ȱ x Localȱ/Remoteȱusingȱ configurationȱsoftwareȱ x Programȱtransferȱ module.ȱ x Fullȱprogrammingȱusingȱ biȬdirectionalȱwirelessȱ keypad.ȱ x Flexibleȱdeviceȱ enrollmentȱbyȱserialȱIDȱ serialȱnumberȱorȱbyȱRFȱ allocation.ȱ x Keypadȱprogrammingȱ menuȱadjustedȱtoȱ existingȱhardware.ȱ BiȬdirectionalȱKeypadȱ x FullyȱWirelessȱȱ x LCDȱdisplayȱ x S.O.Sȱ/ȱTwoȱwayȱ communicationȱ emergencyȱkeyȱ x Doubleȱtamperȱ protectionȱ(Boxȱ&ȱ Wall)ȱȱ ȱ UserȱOperatingȱTools:ȱ x BiȬdirectionalȱ8ȱbuttonȱ keyȱfobȱ x BiȬdirectionalȱKeypadȱ x 4ȱbuttonȱkeyfobȱ x Remoteȱphoneȱoperationȱ x SMSȱ x Configurationȱsoftwareȱ x Webȱbrowserȱ(willȱbeȱ availableȱinȱfutureȱ versionsȱofȱAgility).ȱȱ Codes:ȱ x 1ȱengineerȱcodeȱ x 1ȱsubȱengineerȱcodeȱ x 1ȱgrandȱmasterȱcodeȱ x 32ȱuserȱcodesȱ x 4ȱauthorityȱlevelȱ x Optionalȱ4ȱorȱ6ȱdigitsȱ codeȱdefinitionȱ HomeȱAutomationȱ x 4ȱoutputsȱviaȱwirelessȱI/Oȱ expanderȱ x 16ȱXȬ10ȱoutputsȱviaȱ wirelessȱI/Oȱexpanderȱ x Outputsȱcanȱfollowȱsystemȱ ,ȱpartition,ȱzoneȱorȱuserȱ eventsȱ x Outputsȱcanȱbeȱ scheduled,ȱorȱactivatedȱ automatically,ȱorȱbyȱuserȱ commandȱ(SMS,ȱwebȱ browserȱorȱremoteȱphone)ȱ ȱ FollowȱMe:ȱ x 16ȱfollowȱmeȱ destinationsȱ x Followȱmeȱcanȱbeȱ definedȱasȱvoiceȱ message,ȱSMSȱorȱ Emailȱ x Userȱcontrolȱoverȱtheȱ systemȱ x Securityȱcodeȱ protectionȱȱȱ ȱ Voiceȱcapabilities:ȱ x 2ȬWayȱcommunicationȱ x Remoteȱphoneȱoperationȱ x Fullȱvoiceȱmenuȱguideȱ x Systemȱeventȱmessagingȱ x Localȱannouncementȱ messagesȱ x Voiceȱdescriptionȱforȱ zones,ȱpartitions,ȱetc.ȱȱ WirelessȱFeatures:ȱ x Signalȱjammingȱ indicationȱ x Receiverȱcalibrationȱ x 868MHz/433ȱMHzȱradioȱ frequenciesȱ x Programmableȱ supervisionȱtimeȱ x Tamperȱdetectionȱinȱ transmittersȱ x Lowȱbatteryȱdetectionȱinȱ transmittersȱ Page 1-3 FalseȱCodeȱReduction:ȱ x Swingerȱshutdownȱ x Zoneȱcrossingȱȱ x ReportȱdelayȱtoȱARCȱ x Abortȱalarmȱfeatureȱ x Soakȱtestȱ x Finalȱexitȱzoneȱ AgilityȱEngineerȱManualȱ ȱ Technical Specifications TheȱfollowingȱtechnicalȱspecificationsȱareȱapplicableȱforȱtheȱAgility:ȱ Electrical Characteristics Powerȱ 230VACȱ(Ȭ15%+10%),ȱ50Hz,ȱ50mAȱ Unitsȱconsumptionsȱȱ ȱ Mainȱboard:ȱTypicalȱ130mAȱ GSM:ȱStandȱbyȱ35mA,ȱCommunicationȱ300mAȱ Modem:ȱStandȱbyȱ20mA,ȱCommunicationȱ60mAȱȱ IPȱCard:ȱ90mAȱ(Max)ȱ Backupȱbatteryȱ SealedȱLeadȱAcidȱBatteryȱ6Vȱ3.2ȱAhȱ InternalȱSounderȱintensityȱ 90ȱdBAȱ@1mȱ Operatingȱtemperatureȱ Ȭ10°Cȱtoȱ40°Cȱ(14°Fȱtoȱ131°F)ȱ Storageȱtemperatureȱ Ȭ20°Cȱtoȱ60°Cȱ(Ȭ4°Fȱtoȱ140°F)ȱ Physical Characteristics Dimensionȱ 268.5ȱmmȱxȱ219.5ȱmmȱxȱ64ȱcmȱ(10.57ȱxȱ8.64ȱxȱ2.52ȱinch)ȱ Weightȱ(noȱbattery)ȱ 1.31Kgȱ(Fullȱconfiguration)ȱ GSMȱmodule:ȱ0.045ȱKgȱ Wireless Characteristics RadioȱImmunityȱ AccordingȱtoȱENȱ50130Ȭ4ȱ Frequencyȱ 868.65ȱMHz/433.92ȱMHzȱ ȱ Page 1-4 AgilityȱEngineerȱManualȱȱ ȱ Chapter 2 Installing the Agility ThisȱchapterȱcoversȱtheȱinstallationȱproceduresȱofȱtheȱAgility,ȱasȱfollows:ȱȱ AgilityȱMainȱComponents,ȱpageȱ2Ȭ1ȱ MountingȱtheȱAgility,ȱpageȱ2Ȭ2ȱ Choosingȱtheȱmountingȱlocation,ȱpageȱ2Ȭ2ȱ WallȱMountingȱtheȱAgilityȱpageȱ2Ȭ2ȱ ConnectingȱtheȱBackupȱBattery,ȱpageȱ2Ȭ5ȱ ConnectingȱtheȱAgilityȱtoȱPowerȱSupply,ȱpageȱ2Ȭ6ȱ GroundȱConnection,ȱpageȱ2Ȭ6ȱ DIPȱswitchȱsetting,ȱpageȱ2Ȭ8ȱ ConnectingȱaȱȱtelephoneȱlineȱtoȱtheȱAgility,ȱpageȱ2Ȭ9ȱ SIMȱCardȱInstallation,ȱpageȱ2Ȭ9ȱ ExternalȱAudioȱUnit,ȱpageȱ2Ȭ12ȱ Agility Main Components Theȱillustrationȱbelowȱshowsȱtheȱinternalȱcomponentsȱ(whenȱtheȱMountingȱBracketȱisȱ disassembledȱfromȱtheȱBackȱPanel).ȱ 8 3 3 9 OPEN 2 LOCK 2 10 11 4 18 ON 1 2 3 4 4 1 1 12 5 17 13 6 7 14 5 16 ȱ ConfigurationȱAȱ 15 ConfigurationȱBȱ ȱ ȱ Figureȱ1:ȱAgilityȱMainȱComponentsȱ 1.ȱ InstallationȱBracketȱ 7.ȱ Transformerȱ 13ȱ RSȱ232ȱcommunicationȱconnectorȱ 2.ȱ TelephoneȱJacksȱ 8.ȱ BackȱPanelȱ 14. Batteryȱcompartmentȱ 3.ȱ AudioȱUnitȱterminalsȱ 9.ȱ SIMȱCardȱsocketȱ 15. Batteryȱcompartmentȱcoverȱ 4.ȱ Ribbonȱflatȱcableȱjackȱ 10.ȱ Ribbonȱflatȱȱcableȱ 16. Batteryȱflingȱleadsȱ 5.ȱ ACȱconnectionȱterminals/DCȱSocketȱ 11.ȱ DIPȱSwitchesȱ 17. Tamperȱswitchȱ 6.ȱ Fuseȱȱ 18. IPȱCardȱnetworkȱconnectorȱ 12ȱ PTMȱconnectorȱ Page 2-1 ȱ AgilityȱEngineerȱManualȱ Mounting the Agility IMPORTANT:ȱTheȱAgilityȱhasȱnoȱuserȱreplaceableȱpartsȱ(forȱinstance:ȱpowerȱcord,ȱfuse,ȱbattery,ȱetc.)ȱ onlyȱcertifiedȱengineersȱareȱallowedȱtoȱreplaceȱfaultyȱparts.ȱȱȱ Choosing the mounting location BeforeȱyouȱmountȱtheȱAgility,ȱstudyȱtheȱpremisesȱcarefullyȱinȱorderȱtoȱchooseȱtheȱexactȱ locationȱofȱtheȱunitȱforȱtheȱbestȱpossibleȱcoverageȱandȱyetȱeasilyȱaccessibleȱtoȱprospectiveȱ usersȱofȱtheȱalarmȱsystem.ȱȱ TheȱmountingȱlocationȱofȱtheȱAgilityȱshouldȱbe:ȱ Tryȱtoȱcentrallyȱlocateȱtheȱsystemȱbetweenȱallȱtheȱtransmitters.ȱ NearȱanȱuninterruptedȱACȱoutlet.ȱȱȱ Nearȱaȱtelephoneȱoutlet.ȱ Farȱfromȱsourcesȱofȱinterference,ȱsuchȱas:ȱ Directȱheatȱsourcesȱ Electricalȱnoiseȱsuchȱasȱcomputers,ȱtelevisionsȱetc.ȱ Largeȱmetalȱobjects,ȱwhichȱmayȱshieldȱtheȱantenna.ȱȱ InȱaȱplaceȱwhereȱtheȱalarmȱcanȱbeȱheardȱduringȱPartȱSettingȱmode.ȱ Wall Mounting the Agility TheȱAgilityȱisȱcomprisedȱofȱtwoȱsubȬassemblies:ȱ Mountingȱbracket,ȱ Mainȱunitȱwhichȱinȱitsȱturnȱisȱcomprisedȱfrom:ȱȱ Frontȱpanelȱ(notȱdisassembledȱonȱaȱregularȱinstallationȱprocedure)ȱ Backȱpanelȱ Theȱmountingȱbracketȱisȱmountedȱonȱtheȱwall,ȱusingȱtheȱsuppliedȱproperȱhardware,ȱasȱ describedȱbelow:ȱ ToȱmountȱtheȱAgilityȱonȱtheȱWall:ȱ 1. SeparateȱtheȱMountingȱbracketȱasȱfollows:ȱ a. ReleaseȱtheȱMountingȱbracketȱcaptiveȱlockingȱscrewsȱ(1,ȱFigureȱ2)ȱlocatedȱatȱtheȱ bottomȱofȱtheȱunitȱbyȱturningȱscrewsȱcounterclockwise.ȱȱ 1 ȱ Figureȱ2:ȱMountingȱBracketȱscrewsȱ Page 2-2 AgilityȱEngineerȱManualȱȱ ȱ b. Gently,ȱpullȱupȱtheȱMountingȱbracketȱtoȱaȱ45°ȱangleȱandȱslideȱitȱdownȱtoȱreleaseȱ theȱMountingȱbracketȱ(2,ȱFigureȱ3)ȱfromȱtheȱtwoȱlockingȱtabsȱ(1,ȱFigureȱ3)ȱatȱtheȱ topȱofȱtheȱunit.ȱȱ Note:ȱDoȱnotȱopenȱtheȱMountingȱbracketȱtoȱaȱlargerȱangleȱinȱorderȱnotȱtoȱbreakȱtheȱtwoȱtopȱtabsȱandȱnotȱtoȱ tearȱupȱtheȱribbonȱflatȱcableȱconnectingȱtheȱpowerȱsupplyȱunitȱtoȱtheȱfrontȱpanelȱ(PCB).ȱȱ c. Disconnectȱtheȱribbonȱflatȱcableȱ(3)ȱfromȱtheȱpowerȱsupplyȱunitȱwhileȱleavingȱitȱ connectedȱtoȱtheȱMainȱpanel.ȱ ȱ Figureȱ3:ȱMountingȱBracketȱremovalȱ 2. HoldȱtheȱMountingȱbracketȱagainstȱtheȱwallȱasȱaȱtemplateȱandȱmarkȱtheȱlocationsȱforȱ theȱmountingȱholesȱ(5ȱmountingȱholesȱitemȱ1,ȱandȱanȱadditionalȱholeȱforȱsecuringȱtheȱ tamperȱprotectionȱbracketȱitemȱ2,ȱareȱavailable,ȱseeȱFigureȱ4).ȱȱ 3. Drillȱtheȱdesiredȱmountingȱholesȱandȱplaceȱtheȱscrewȱanchors.ȱUseȱtheȱsuppliedȱ5ȱ PhilipsȱpanȱheadȱscrewsȱtoȱattachȱtheȱMountingȱbracketȱtoȱtheȱwallȱ(ST4.2ȱmmȱxȱ32ȱ mmȱDINȱ7981).ȱ 4. Accordingȱtoȱtheȱlocationȱofȱtheȱwallȱcables,ȱrouteȱandȱinsertȱtheȱwiresȱandȱcablesȱviaȱ theȱcable’sȱopeningsȱ(3)ȱ(includingȱACȱcableȱandȱtelephoneȱcable),ȱseeȱfigureȱ3.ȱ 5. Ifȱrequired,ȱremoveȱcableȱknockoutsȱ(5)ȱtoȱallowȱwireȱpassage.ȱȱ 6. Anchorȱcablesȱwithȱdedicatedȱhooksȱ(4).ȱȱ Page 2-3 ȱ AgilityȱEngineerȱManualȱ 1 1 4 4 3 3 3 2 3 2 1 1 ȱ ConfigurationȱAȱ ȱ ConfigurationȱBȱ 5 6 7 ȱ Figureȱ4:ȱWallȱInstallationȱ 7. AdjustȱtheȱTamperȱswitchȱ(usingȱaȱflatȱscrewdriver)ȱaccordingȱtoȱyourȱpreferredȱ configuration.ȱ a. BoxȱandȱWallȱconfigurationȱ(seeȱFigureȱ4,ȱdetailȱ6)ȱȬȱTriggersȱtheȱtamperȱwhenȱtheȱ boxȱorȱtheȱwallȱmountingȱareȱtampered.ȱȱ b. Boxȱonlyȱconfigurationȱ(seeȱFigureȱ4,ȱdetailȱ7)ȱ–ȱTriggersȱtheȱtamperȱwhenȱtheȱboxȱ isȱtampered.ȱ Page 2-4 AgilityȱEngineerȱManualȱȱ ȱ Connecting the Backup Battery TheȱAgilityȱhasȱsafetyȱapproved,ȱsealedȱleadȱacidȱ6V,ȱ3.2ȱAhȱrechargeableȱbackupȱbatteryȱ usedȱinȱtimeȱofȱmainȱpowerȱfailure:ȱ Note:ȱTheȱbatteryȱisȱsuppliedȱwithȱtheȱAgility.ȱ ToȱinsertȱtheȱBackupȱbattery:ȱ Removeȱtheȱbatteryȱcompartmentȱcoverȱscrewȱ(seeȱFigureȱ5,3)ȱlocatedȱatȱtheȱtopȱofȱtheȱ coverȱbyȱturningȱscrewȱcounterclockwiseȱandȱpullȱtheȱAgilityȱbatteryȱcoverȱoutward.ȱȱ 1 2 3 2 ȱ Figureȱ5:ȱBatteryȱCompartmentȱ a.ȱInsertȱtheȱbatteryȱintoȱitsȱplaceȱandȱconnectȱtheȱflyingȱleadsȱtoȱtheȱbatteryȱ accordingȱtoȱtheȱcorrectȱpolarityȱ(Redȱ+)ȱ(BlackȱȬ).ȱ b.ȱReturnȱtheȱbatteryȱcompartmentȱcoverȱ(afterȱplacingȱtheȱbatteryȱin)ȱandȱsecureȱ withȱlockingȱscrew.ȱ Note:ȱTheȱAgilityȱRechargeableȱbatteryȱshouldȱbeȱchargedȱforȱatȱleastȱ24ȱhours.ȱȱ ȱ Important:ȱȱWhenȱreplacingȱtheȱbatteryȱbeȱsureȱtoȱbuyȱtheȱsameȱtype.ȱFailureȱtoȱcomplyȱwithȱthisȱinstructionȱ mayȱresultȱinȱdamageȱtoȱpersonnelȱand/orȱequipment.ȱ ȱ ȱDisposeȱofȱusedȱbatteriesȱaccordingȱtoȱtheȱproperȱinstructions.ȱ Page 2-5 ȱ AgilityȱEngineerȱManualȱ Connecting the Agility to Power Supply - Configuration A Note:ȱTheȱAgilityȱpanelȱisȱpermanentlyȱconnectedȱtoȱtheȱmains.ȱTheȱconnectionȱmustȱbeȱmadeȱaccordingȱtoȱ yourȱcountryȇsȱlocalȱregulations.ȱAsȱaȱgeneralȱguideline,ȱconnectȱtheȱLiveȱNeutralȱandȱGroundȱusingȱaȱ safetyȱapprovedȱ3Ȭwireȱ18AWGȱpowerȱcableȱ(14ȬmmȱminimumȱdiameterȱflexibleȱPVCȱcableȱwhichȱ compliesȱwithȱIEC60227).ȱTheȱcableȱshouldȱbeȱbroughtȱtoȱtheȱAgilityȱpanelȱinȱaȱprotectiveȱplasticȱ conduitȱ(diameterȱȬȱ16mmȱminimum).ȱ ȱ Aȱ2Ȭpoleȱ16Aȱcircuitȱbreakerȱandȱearthȱleakageȱprotectorȱshouldȱbeȱusedȱtoȱdisconnectȱtheȱliveȱ conductor,ȱandȱshouldȱbeȱprovidedȱasȱpartȱofȱtheȱbuildingȱinstallation.ȱ TheȱAgilityȱisȱpoweredȱbyȱaȱsafetyȱapprovedȱ230VAC.ȱȱ 1.ȱȱRemoveȱtheȱpowerȱsupplyȱunitȱcoverȱ(Figureȱ6,ȱ1).ȱ 2.ȱȱConnectȱtheȱpowerȱwireȱ(Safetyȱapproved,ȱSVT,ȱ18AWG,ȱ0.75mm2)ȱtoȱtheȱȱȱ ȱpowerȱterminalȱlocatedȱonȱtheȱpowerȱsupplyȱunitȱ(TB1)ȱ(2,ȱFigureȱ6).ȱȱ Note:ȱTheȱpowerȱwireȱisȱnotȱsuppliedȱwithȱtheȱAgility.ȱ 3.ȱȱDOȱNOTȱconnectȱtheȱcableȱtoȱtheȱwallȱpowerȱsupplyȱatȱthisȱpoint.ȱ Ground Connection Groundingȱprovidesȱaȱdegreeȱofȱprotectionȱagainstȱlightningȱandȱinducedȱtransientsȱforȱ anyȱpieceȱofȱelectronicȱequipmentȱthatȱmay,ȱdueȱtoȱlightningȱorȱstaticȱdischarge,ȱ experienceȱpermanentȱorȱgeneralȱmalfunctions.ȱTheȱidealȱgroundȱisȱconsideredȱtoȱbeȱaȱ unifiedȱearthȱgroundȱinȱwhichȱanȱ8ȬfootȱcopperȬcladȱrod,ȱlocatedȱcloseȱtoȱtheȱexistingȱ powerȱandȱtelephoneȱgroundȱrods,ȱisȱsunkȱseveralȱfeetȱintoȱtheȱearth.ȱAppropriateȱ hardwareȱandȱclampsȱareȱthenȱusedȱtoȱelectricallyȱconnectȱeachȱofȱtheseȱrodsȱtogetherȱandȱ thenȱtoȱtheȱgroundȱterminalȱofȱtheȱdeviceȱtoȱbeȱprotected.ȱȱ Itȱmayȱbeȱpossibleȱtoȱuseȱanȱexistingȱelectricalȱgroundȱonȱtheȱpremisesȱifȱoneȱisȱcloseȱ enoughȱtoȱtheȱAgility.ȱWhenȱconnectingȱtheȱgroundȱwire,ȱuseȱaȱsolidȱ14Ȭgaugeȱwireȱ[orȱ largerȱ(numericallyȱlower)ȱsize].ȱKeepȱthisȱwireȱasȱshortȱasȱpossibleȱandȱdoȱnotȱrunȱitȱinȱ conduit,ȱcoilȱit,ȱbendȱitȱsharply,ȱorȱrunȱitȱalongsideȱotherȱwiring.ȱIfȱyouȱmustȱbendȱitȱorȱ changeȱitsȱdirection,ȱitȱshouldȱhaveȱaȱradiusȱofȱatȱleastȱ8ȱinchesȱatȱtheȱpointȱfromȱwhichȱitȱ isȱbent.ȱȱIfȱinȱdoubt,ȱyouȱmayȱwantȱtoȱenlistȱtheȱhelpȱofȱaȱlicensedȱelectricianȱinȱmattersȱ concerningȱsuchȱgrounding.ȱ ȱ Toȱconnectȱtoȱgroundȱ(Earth):ȱ ConnectȱbetweenȱtheȱAgility’sȱgroundȱterminalȱandȱanȱacceptableȱelectricalȱgroundȱ connectionȱforȱtheȱlightningȱtransientȱprotectiveȱdevicesȱinȱthisȱproductȱtoȱbeȱeffective.ȱȱȱ Important:ȱConnectingȱtoȱgroundȱmustȱbeȱperformedȱaccordingȱtoȱtheȱlocalȱNationalȱElectricalȱCode.ȱ Page 2-6 AgilityȱEngineerȱManualȱȱ ȱ 2 ~ TB1 1 ȱ Figureȱ6:ȱConnectingȱACȱPowerȱwiresȱ Connecting the Agility to Power Supply - Configuration B 1. TheȱAgilityȱisȱpoweredȱbyȱaȱ9VDC/1.0AȱTransformer.ȱ 2. Connectȱtheȱtransformerȱpowerȱjackȱtoȱtheȱpowerȱsupplyȱlocatedȱonȱtheȱ powerȱsupplyȱcardȱ(1,ȱFigureȱ6A).ȱȱ 3. DOȱNOTȱconnectȱtheȱtransformerȱinletȱcableȱtoȱtheȱwallȱpowerȱsupplyȱatȱ thisȱpoint.ȱ From 9VDC/1.0A Transformer 1 2 Figureȱ6A:ȱConnectingȱDCȱPowerȱCableȱ Page 2-7 ȱ AgilityȱEngineerȱManualȱ Completing Installation 1.ȱȱSetȱtheȱDIPȱSwitchesȱaccordingȱtoȱtheȱDIPȱSwitchȱSettingȱsectionȱ(seeȱpageȱ2Ȭ8).ȱ 2.ȱȱConnectȱtheȱribbonȱflatȱcableȱbetweenȱtheȱmainȱpanelȱandȱtheȱmountingȱbracketȱ(J1).ȱȱȱ 3.ȱȱMountȱtheȱMainȱunitȱtoȱtheȱmountingȱbracketȱusingȱcaptiveȱlockingȱscrews.ȱ 4.ȱȱPlugȱinȱtheȱpowerȱcableȱtoȱtheȱwallȱpowerȱoutlet.ȱ 5.ȱȱPowerȱupȱtheȱAgility.ȱ DIP switch setting ON Factory Default ȱ DIPȱSwitchȱ1ȱ(EȬA):ȱExternalȱAudio:ȱUsedȱtoȱdefineȱifȱtheȱvoiceȱofȱtheȱAgilityȱwillȱgoȱfromȱ theȱmainȱunitȱorȱfromȱanȱExternalȱAudioȱUnit.ȱWhenȱtheȱexternalȱunitȱisȱconnectedȱtoȱtheȱ AgilityȱtheȱvoiceȱwillȱbeȱheardȱonlyȱthroughȱtheȱAudioȱvoiceȱunit.ȱ ON:ȱExternalȱAudioȱUnitȱisȱconnectedȱtoȱtheȱAgilityȱȱ OFFȱ(Default):ȱExternalȱAudioȱunitȱnotȱconnectedȱtoȱtheȱAgility.ȱ DIPȱSwitchȱ2ȱ(DFLT):ȱDefaultȱjumper:ȱUsedȱwhenȱperformingȱtheȱfollowingȱ3ȱoperations:ȱ 1.ȱToȱreturnȱengineer,ȱsubȬengineerȱandȱgrandȱmasterȱcodesȱtoȱtheirȱdefaultȱfactoryȱ values.ȱSetȱthisȱDIPȱswitchȱtoȱON,ȱdisconnectȱallȱpowerȱandȱthenȱreconnectȱtheȱpower.ȱ 1 2 3 4 Note:ȱCodeȱLengthȱdoesȱnotȱchange.ȱ 2.ȱToȱmanuallyȱeraseȱwirelessȱdevices.ȱSetȱthisȱDIPȱswitchȱtoȱONȱwhileȱpowerȱisȱ connected.ȱExecuteȱaȱlongȱpressȱonȱtheȱmainȱunitȱbuttonȱuntilȱaȱbeep,ȱindicatingȱthatȱallȱ wirelessȱdevicesȱhaveȱbeenȱerased,ȱisȱheard.ȱ 3.ȱToȱsaveȱorȱtransferȱdataȱtoȱorȱfromȱtheȱPTMȱdevice.ȱȱ ON:ȱToȱtransferȱdataȱfromȱtheȱPTMȱtoȱtheȱpanel.ȱȱ OFF:ȱToȱtransferȱdataȱfromȱtheȱpanelȱtoȱtheȱPTM.ȱ(ReferȱtoȱChapterȱ3ȱforȱtheseȱprocedures.)ȱ DIPȱSwitchȱ3ȱ(PRGM):ȱȱEnablesȱloadingȱlocalȱsoftwareȱupdatesȱtoȱtheȱAgilityȱ ON:ȱsoftwareȱupdatesȱtoȱtheȱAgilityȱcanȱbeȱloadedȱ OFFȱ(Default):ȱsoftwareȱupdatesȱtoȱtheȱAgilityȱcanȱnotȱbeȱloadedȱ DIPȱSwitchȱ4ȱ(BAT):ȱDefinesȱtheȱBatteryȱDischargeȱProtectionȱoptionȱsettingsȱ ȱ ON:ȱBatteryȱDischargeȱProtectionȱisȱOFF:ȱTheȱbatteryȱmayȱbeȱtotallyȱdischargedȱduringȱ continuousȱACȱfailure,ȱthusȱbatteryȱreplacementȱmayȱbeȱrequiredȱ(noȱdeepȱdischargeȱ protection).ȱ Note:ȱȱInȱthisȱpositionȱtheȱAgilityȱwillȱstartȱtoȱoperateȱfromȱaȱbatteryȱpowerȱsupplyȱwhetherȱitȱisȱconnectedȱ toȱtheȱMainsȱorȱnot.ȱ ȱ OFFȱ(Default):ȱBatteryȱdeepȱDischargeȱProtectionȱisȱON:ȱIfȱanȱACȱpowerȱoutageȱoccurs,ȱ theȱAgilityȱautomaticallyȱdisconnectsȱtheȱbatteryȱwhenȱitsȱbackupȱbatteryȱvoltageȱdropsȱ belowȱ5.8ȱVDC,ȱinȱorderȱtoȱpreventȱȈdeepȱdischarge”ȱthatȱmayȱdamageȱtheȱbattery.ȱ Note:ȱȱInȱthisȱpositionȱtheȱAgilityȱwillȱnotȱstartȱtoȱoperateȱfromȱaȱbatteryȱpowerȱsupply,ȱunlessȱ connectedȱtoȱtheȱMainsȱfirst.ȱ Page 2-8 AgilityȱEngineerȱManualȱȱ ȱ Connecting a telephone line to the Agility Connectȱtheȱsystemȱtoȱaȱtelephoneȱlineȱifȱtheȱsystemȱconfigurationȱincludesȱanȱinternalȱ modemȱ(identicalȱforȱConfigurationȱAȱandȱB).ȱ 1. ConnectȱtheȱincomingȱtelephoneȱlineȱtoȱtheȱplugȬinȱCONN2ȱjackȱRJ11ȱ(pinsȱ2,ȱ3)ȱorȱtoȱ plugȬinȱCONN3ȱRJ31ȱ(pinsȱ4,ȱ5)ȱ(seeȱFigureȱ7:ȱTelephoneȱLineȱJacks).ȱ 2. ConnectȱanyȱtelephoneȱonȱtheȱpremisesȱtoȱtheȱplugȬinȱCONN2ȱȱjackȱRJ11ȱ (pinsȱ1,ȱ4)ȱorȱtoȱplugȬinȱCONN3ȱRJ31ȱ(pinsȱ1,ȱ8)ȱ(seeȱFigureȱ7:ȱTelephoneȱ LineȱJacks).ȱ NOTE:ȱToȱensureȱlineȱseizureȱcapability,ȱandȱcomplyȱwithȱFCCȱpartȱ68ȱregulations,ȱtheȱequipmentȱmustȱbeȱ connectedȱdirectlyȱtoȱtheȱPhoneȱcompanyȱlinesȱ(ȇCOȇ).ȱWhetherȱconnectedȱviaȱRJ11,ȱRJ31,ȱtheȱlineȱ portȱmustȱbeȱconnectedȱtoȱtheȱCOȱlinesȱwithoutȱanyȱotherȱphonesȱorȱotherȱtelecomȱequipmentȱ betweenȱthem.ȱOtherȱtelecomȱequipmentȱcanȱbeȱconnectedȱonlyȱafterȱ(inȱseries)ȱtheȱalarmȱpanel.ȱȱ CONN2 RJ11 CONN3 RJ31 ȱ Figureȱ7:ȱTelephoneȱLineȱJacksȱ Page 2-9 ȱ AgilityȱEngineerȱManualȱ Connecting a network cable to the Agility IfȱyourȱAgilityȱisȱequippedȱwithȱanȱIPȱCard,ȱyouȱshouldȱconnectȱtheȱincomingȱnetworkȱ cableȱinȱorderȱtoȱenableȱIPȱCommunication.ȱ 1.ȱȱSeparateȱtheȱAgilityȱfromȱtheȱmountingȱbracket.ȱȱȱ 2.ȱȱAccordingȱtoȱtheȱlocationȱofȱtheȱnetworkȱcable,ȱrouteȱandȱinsertȱtheȱcableȱviaȱtheȱcable’sȱȱȱ openingsȱ(seeȱfigureȱ3).ȱ 3.ȱȱIfȱrequired,ȱremoveȱcableȱknockoutsȱ(5,ȱFigureȱ3)ȱtoȱallowȱcableȱpassage.ȱȱ 4.ȱȱConnectȱtheȱincomingȱnetworkȱcableȱtoȱtheȱplugȬin.ȱ ȱ Page 2-10 AgilityȱEngineerȱManualȱȱ ȱ SIM Card Installation IfȱyourȱAgilityȱisȱequippedȱwithȱaȱGSM/GPRSȱmodule,ȱyouȱshouldȱinsertȱaȱSIMȱcardȱinȱ orderȱtoȱenableȱcommunicationȱthroughȱtheȱGSM/GPRSȱnetwork.ȱ 1. InsertȱtheȱSIMȱintoȱtheȱdedicatedȱSIMȱcardȱslotȱlocatedȱonȱtheȱrearȱsideȱofȱtheȱbackȱpanelȱ (SeeȱFigureȱ1:ȱAgilityȱMainȱComponents).ȱȱ LOCK LOCK 1. Slide down SIM card hatch . 2. Open the SIM card hatch. Insert SIM card into dedicated slot. OPEN OPEN OPEN LOCK SIM Card 3. Close the SIM card hatch . Slide up to lock. ȱ Figureȱ8:ȱȱSIMȱCardȱInsertionȱ ȱ Important:ȱDoȱnotȱinstallȱSIMȱcardȱwhileȱpowerȱisȱappliedȱtoȱtheȱAgility.ȱȱȱ ȱ ȱ DoȱnotȱtouchȱSIMȱCardȱconnectors!ȱIfȱdoingȱso,ȱyouȱmayȱreleaseȱanȱelectricalȱdischargeȱthatȱcouldȱ ȱ damageȱtheȱSIMȱcard.ȱ 2. IfȱaȱPINȱcodeȱisȱrequiredȱforȱtheȱSIMȱcard,ȱtheȱAgilityȱwillȱindicateȱaȱPINȱcodeȱfault.ȱ Toȱfixȱtheȱfault,ȱandȱthusȱenableȱtheȱSIMȱcardȱtoȱoperateȱproperly,ȱenterȱtheȱPINȱcodeȱ number,ȱlocatedȱinȱtheȱCommunicationȱ>ȱGSMȱparametersȱmenu.ȱȱ Note:ȱEnsureȱthatȱyouȱhaveȱtheȱPINȱcode.ȱBeȱawareȱthatȱafterȱthreeȱwrongȱattemptsȱ(recognizedȱbyȱtheȱSIMȱ card)ȱtoȱenterȱaȱPINȱnumber,ȱtheȱSIMȱcardȱwillȱlock.ȱȱ ȱ YouȱwillȱhaveȱtoȱcontactȱyourȱlocalȱcellularȱproviderȱtoȱunlockȱtheȱSIMȱcard.ȱ 3. IfȱyouȱwantȱtoȱdisableȱtheȱSIMȱPINȱcodeȱyouȱshouldȱfollowȱtheȱsteps:ȱ a. InsertȱtheȱSIMȱcardȱintoȱaȱstandardȱGSMȱmobileȱphone.ȱȱ b. InsertȱtheȱPINȱcode.ȱ c. AccessȱtheȱphoneȱsecurityȱmenuȱandȱselectingȱPINȱOFF.ȱOnceȱdone,ȱreȬtestȱbyȱ switchingȱtheȱphoneȱOFF,ȱthenȱswitchingȱON.ȱTheȱPINȱcodeȱshouldȱnotȱbeȱrequestedȱ again.ȱ 4. OnceȱtheȱSIMȱcardȱisȱplacedȱitȱisȱrecommendedȱtoȱtestȱtheȱoperationȱofȱtheȱSIMȱbyȱ conductingȱaȱcallȱandȱtestingȱtheȱGSMȱsignalȱstrength.ȱForȱmoreȱinformationȱreferȱtoȱtheȱ programmingȱmenusȱofȱtheȱGSMȱmenu.ȱȱ Note:ȱInȱsomeȱcountriesȱanȱSMSȱcenterȱphoneȱnumberȱmightȱbeȱrequiredȱinȱorderȱtoȱenableȱSMSȱmessaging.ȱ Thisȱphoneȱnumberȱisȱprovidedȱbyȱtheȱprovider.ȱProgrammingȱtheȱSMSȱcenterȱphoneȱintoȱtheȱSIMȱcanȱ beȱdoneȱusingȱaȱstandardȱGSMȱmobileȱphoneȱorȱfromȱtheȱAgilityȱkeypadȱorȱconfigurationȱsoftware.ȱ Page 2-11 ȱ AgilityȱEngineerȱManualȱ External Audio Unit TheȱAgilityȱenablesȱtoȱconnectȱanȱexternalȱAudioȱUnitȱinsteadȱofȱtheȱinternalȱunitȱinȱorderȱ toȱlistenȱtoȱtheȱsystemȇsȱaudioȱmessagesȱinȱaȱdistanceȱfromȱtheȱmainȱunit.ȱInȱadditionȱtheȱ unitȱenablesȱyouȱtoȱtalkȱintoȱyourȱpremises.ȱȱȱ ToȱconnectȱtheȱAudioȱunit:ȱȱ 1. WireȱtheȱAudioȱunitȱtoȱtheȱAgilityȱasȱdisplayedȱinȱtheȱWiringȱDiagramȱdescribedȱ inȱFigureȱ9.ȱTheȱterminalsȱforȱwiringȱtheȱAudioȱUnitȱtoȱtheȱAgilityȱareȱlocatedȱonȱ mountingȱbracketȱtheȱAgility.ȱ 2. SetȱDIPȱSwitchȱ1ȱ(EȬȱA)ȱ(ExternalȱAudio)ȱtoȱOnȱposition.ȱȱȱȱȱ ȱ Figureȱ9:ȱȱWiringȱtheȱExternalȱAudioȱUnitȱȱtoȱAgilityȱȱ ȱ ȱ Page 2-12 AgilityȱEngineerȱManualȱȱ ȱ Chapter 3 Engineer Programming Programming Methods Thereȱareȱ4ȱavailableȱoptionsȱforȱprogrammingȱtheȱAgility:ȱ ConfigurationȱSoftwareȱ WirelessȱKeypadȱ EngineerȱKeypadȱ PTMȱ Configuration Software AȱsoftwareȱapplicationȱthatȱenablesȱyouȱtoȱprogramȱtheȱAgilityȱfromȱaȱPCȱcomputer.ȱItȱ offersȱtheȱfollowingȱalternatives:ȱ Workingȱlocally,ȱthroughȱaȱportableȱcomputerȱconnectedȱtoȱtheȱAgilityȱviaȱcableȱ Workingȱatȱaȱremoteȱsite,ȱcommunicatingȱwithȱtheȱAgilityȱviaȱaȱphoneȱline,ȱ modemȱorȱIPȱaddress.ȱ ForȱfurtherȱinformationȱonȱprogrammingȱtheȱAgilityȱviaȱtheȱConfigurationȱsoftware,ȱreferȱ toȱtheȱAgilityȱConfigurationȱSoftwareȱmanual.ȱ Wireless Keypad TheȱAgilityȱcanȱbeȱfullyȱconfiguredȱviaȱtheȱwirelessȱkeypad.ȱ Notes:ȱȱ 1.ȱTheȱAgilityȱcanȱbeȱprogrammedȱviaȱanyȱofȱtheȱ2ȱwayȱkeypadsȱinȱyourȱsystem,ȱbutȱonlyȱusingȱoneȱ keypadȱatȱaȱtimeȱforȱprogramming.ȱȱ 2.ȱDuringȱengineerȱprogramming,ȱtheȱkeypadȱwillȱturnȱoffȱafterȱ4ȱminutesȱifȱnoȱentryȱhasȱbeenȱmadeȱ toȱtheȱkeys.ȱPressȱanyȱbuttonȱtoȱrestoreȱtheȱkeypad.ȱItȱwillȱdisplayȱtheȱlastȱparameterȱyouȱwereȱ workingȱon.ȱ ȱ ToȱprogramȱtheȱAgilityȱviaȱtheȱWirelessȱKeypad,ȱfollowȱthisȱprocedure:ȱ 1. Performȱsystemȱdeviceȱallocationȱforȱtheȱkeypadȱ(referȱtoȱpageȱ3Ȭ4).ȱ 2. ȱandȱenterȱtheȱengineerȱcodeȱ(defaultȱcodeȱisȱ0132).ȱTheȱkeypadȱwillȱ Pressȱ soundȱaȱconfirmationȱsound.ȱ Note:ȱIfȱaȱGrandȱMasterȱcodeȱisȱrequiredȱtoȱconfirmȱtheȱengineerȱcode,ȱitȱshouldȱbeȱenteredȱatȱthisȱ stageȱafterȱtheȱengineerȱcode.ȱ Page 3-1 ȱ 3. AgilityȱEngineerȱManualȱ GoȱtoȱtheȱProgrammingȱmenuȱandȱpressȱ .ȱOnceȱtheȱpanelȱisȱinȱprogrammingȱ mode,ȱtheȱAgilityȱmainȱunitȱLEDsȱwillȱflashȱsimultaneouslyȱandȱaȱconfirmationȱ soundȱwillȱbeȱheard.ȱ Note:ȱTheȱengineerȱcanȱalsoȱprogramȱuserȱactivitiesȱbyȱselectingȱtheȱActivitiesȱmenuȱinsteadȱofȱ theȱProgrammingȱmenu.ȱUseȱtheȱ ȱbuttonsȱtoȱnavigateȱbetweenȱtheȱmenus.ȱ Engineer Keypad Forȱthoseȱsystemsȱthatȱdoȱnotȱhaveȱkeypads,ȱRISCOȱGroupȱoffersȱtheȱAgilityȱengineerȱaȱ temporaryȱkeypadȱtoȱbeȱusedȱasȱanyȱAgilityȱwirelessȱkeypadȱforȱconfiguringȱaȱsystem.ȱAnȱ hourȱafterȱexitingȱtheȱprogrammingȱmodeȱtheȱEngineerȱKeypadȱwillȱbeȱerasedȱfromȱtheȱ Agilityȱmemoryȱorȱwhenȱpowerȱisȱlostȱtoȱtheȱsystem.ȱȱ ȱ ToȱprogramȱtheȱAgilityȱviaȱtheȱEngineerȱKeypad,ȱfollowȱthisȱprocedure:ȱ 1. ToȱallocateȱtheȱEngineerȱKeypadȱintoȱtheȱsystemȱperformȱaȱshortȱpressȱonȱtheȱ mainȱunitȱbutton.ȱȱ 2. Pressȱtheȱ ȱbuttonsȱonȱtheȱkeypadȱsimultaneouslyȱuntilȱtheȱfollowingȱ messageȱappears:ȱ ȱ 3. EnterȱtheȱGrandȱMasterȱcodeȱandȱpressȱ isȱheard:ȱ“EngineerȱKeypadȱAllocated”.ȱ .ȱTheȱfollowingȱconfirmationȱmessageȱ Note:ȱWhenȱaȱwrongȱGrandȱMasterȱcodeȱisȱentered,ȱtheȱkeypadȱwillȱbeȱdeleted.ȱToȱcontinueȱ thisȱprocedure,ȱperformȱreallocationȱofȱtheȱkeypad.ȱȱ 4. Followȱstepsȱ2ȱandȱ3ȱofȱtheȱwirelessȱkeypadȱ(seeȱpageȱ3Ȭ1)ȱtoȱbeginȱprogrammingȱ theȱsystem.ȱ PTM: Data Storing Device TheȱPTMȱisȱaȱtinyȱcircuitȱboardȱintoȱwhichȱtheȱAgilityȱpanelȱcanȱtransmitȱaȱcopyȱofȱtheȱ systemȇsȱconfiguration.ȱTheȱPTMȱstoresȱthisȱcopyȱandȱcanȱalsoȱtransmitȱtheȱconfigurationȱ informationȱbackȱtoȱtheȱAgilityȱpanel.ȱ ȱ ToȱtransferȱtheȱsystemȱconfigurationȱfromȱtheȱpanelȱtoȱtheȱPTM,ȱfollowȱthisȱprocedure:ȱ 1. DisconnectȱtheȱflatȱcableȱandȱremoveȱtheȱAgilityȱmainȱunitȱfromȱitsȱwallȱbracket.ȱ Note:ȱMakeȱsureȱtheȱbatteryȱisȱinsertedȱintoȱtheȱmainȱunit.ȱ Page 3-2 AgilityȱEngineerȱManualȱȱ 2. 3. 4. 5. 6. 7. ȱ MakeȱsureȱthatȱDipswitchȱ2ȱisȱsetȱtoȱOFFȱ(defaultȱsetting).ȱ PlaceȱtheȱPTMȱontoȱtheȱ5ȬpinȱPTMȱlocatedȱonȱtheȱrearȱofȱtheȱmainȱunitȱPCB.ȱTheȱ PTMȱLEDȱwillȱturnȱon.ȱ Pressȱtheȱmainȱunitȱbuttonȱforȱ5ȱseconds.ȱTheȱPTMȱLEDȱwillȱflashȱquicklyȱduringȱ theȱtransmissionȱofȱinformationȱtoȱtheȱPTM.ȱ Onceȱtransmissionȱisȱcomplete,ȱtheȱpanelȱwillȱsoundȱaȱconfirmationȱbeepȱandȱtheȱ PTMȱLEDȱwillȱstopȱflashingȱandȱturnȱonȱsteady.ȱȱ DisconnectȱtheȱPTMȱfromȱtheȱmainȱunit.ȱ Reconnectȱtheȱflatȱcableȱtoȱtheȱmainȱunitȱandȱreplaceȱtheȱmainȱunitȱinȱitsȱwallȱ bracket.ȱ ȱȱ ToȱtransferȱtheȱsystemȱconfigurationȱfromȱtheȱPTMȱtoȱtheȱAgilityȱpanel,ȱfollowȱthisȱ procedure:ȱ 1. DisconnectȱtheȱflatȱcableȱandȱremoveȱtheȱAgilityȱmainȱunitȱfromȱitsȱwallȱbracket.ȱ Note:ȱMakeȱsureȱtheȱbatteryȱisȱinsertedȱintoȱtheȱmainȱunit.ȱ MakeȱsureȱthatȱtheȱDefaultȱEnableȱsystemȱflagȱisȱonȱ 2. 3. 4. 5. SetȱDipswitchȱ2ȱtoȱON.ȱ PlaceȱtheȱPTMȱontoȱtheȱ5ȬpinȱPTMȱconnectorȱlocatedȱonȱtheȱmainȱunitȱPCB.ȱ AllȱLEDSȱonȱtheȱmainȱunitȱwillȱbeginȱtoȱflashȱsimultaneously.ȱTheȱPTMȱLEDȱwillȱ flashȱquicklyȱduringȱtheȱtransmissionȱofȱinformationȱtoȱtheȱpanel.ȱ Onceȱtransmissionȱisȱcomplete,ȱtheȱpanelȱwillȱsoundȱaȱconfirmationȱbeep.ȱ Note:ȱȱIfȱtheȱprocedureȱfailsȱtheȱpanelȱwillȱmakeȱ3ȱshortȱerrorȱbeeps,ȱandȱyouȱwillȱneedȱtoȱdoȱtheȱ procedureȱagainȱ 6. 7. 8. DisconnectȱtheȱPTMȱfromȱtheȱmainȱunit.ȱ ResetȱDipswitchȱ2ȱtoȱOFF.ȱ Reconnectȱtheȱflatȱcableȱtoȱtheȱmainȱunitȱandȱreplaceȱtheȱmainȱunitȱinȱitsȱwallȱ bracket.ȱ Page 3-3 ȱ AgilityȱEngineerȱManualȱ Wireless Device Allocation Eachȱwirelessȱdeviceȱmustȱidentifyȱitselfȱtoȱtheȱsystemȱreceiver.ȱTheȱfollowingȱsectionȱ describesȱtheȱdifferentȱwaysȱtoȱallocateȱallȱofȱyourȱdevicesȱtoȱtheȱsystemȱinȱorderȱtoȱlaterȱ configureȱeachȱdeviceȇsȱparametersȱȱ Theȱlearningȱprocedureȱbetweenȱtheȱwirelessȱdevicesȱandȱtheȱmainȱunitȱcanȱbeȱperformedȱ eitherȱfromȱtheȱmainȱunit,ȱaȱwirelessȱkeypadȱorȱviaȱtheȱConfigurationȱSoftware.ȱȱ Quick Allocation using the main unit button Toȱperformȱquickȱallocationȱusingȱtheȱmainȱunitȱbutton,ȱfollowȱthisȱprocedure:ȱ Note:ȱToȱenableȱQuickȱAllocationȱmodeȱtheȱSystemȱbitȱȈQuickȱLearnȈȱshouldȱbeȱenabled.ȱ 1. SetȱtheȱmainȱunitȱtoȱLearnȱmodeȱwithȱaȱlongȱpressȱonȱtheȱmainȱunitȱbutton.ȱEachȱ LEDȱwillȱlightȱupȱoneȱafterȱanother.ȱ Note:ȱTheȱunitȱwillȱsoundȱeachȱtimeȱyouȱenterȱorȱexitȱtheȱLearnȱmode. 2. 3. Sendȱaȱtransmissionȱfromȱeachȱdeviceȱ(referȱtoȱtheȱTransmittersȱwriteȱmessageȱ methodȱtableȱinȱsection).ȱTheȱsystemȱwillȱautomaticallyȱidentifyȱeachȱdeviceȱ accordingȱtoȱdifferentȱcategoriesȱ(forȱexample:ȱdetectors,ȱsounders,ȱkeypads,ȱ remoteȱcontrolsȱetc.)ȱandȱenterȱeachȱdeviceȱandȱitsȱdefaultȱvalueȱintoȱtheȱunitȇsȱ memory.ȱEachȱdeviceȱreceivesȱanȱindexȱnumberȱfromȱtheȱsystem.ȱ ExitȱtheȱLearnȱmodeȱwithȱaȱshortȱpressȱonȱtheȱmainȱunitȱbutton.ȱ Allocation using the keypad Itȱisȱpossibleȱtoȱperformȱallocationȱviaȱtheȱkeypadȱinȱtwoȱdifferentȱways:ȱRFȱAllocationȱorȱ byȱenteringȱtheȱdevice’sȱserialȱcode.ȱ ȱ ToȱperformȱRFȱAllocationȱviaȱtheȱkeypad,ȱfollowȱthisȱprocedure:ȱ 1. GoȱtoȱtheȱEngineerȱmenuȱandȱselectȱProgrammingȱÆȱRadioȱDeviceȱÆȱAllocationȱ Æȱ1)ȱRFȱAllocation.ȱTheȱsystemȱimmediatelyȱgoesȱintoȱLearnȱmode.ȱȱ 2. Sendȱaȱtransmissionȱfromȱtheȱdevice.ȱ(Seeȱtable:ȱTransmittersȱwriteȱmessageȱmethod)ȱ 3. Theȱmainȱunitȱwillȱacknowledgeȱtheȱtransmissionȱwithȱaȱsound.ȱWhenȱtheȱsystemȱ recognizesȱtheȱdeviceȱtheȱkeypadȱLCDȱwillȱdisplayȱtheȱdeviceȇsȱserialȱnumberȱandȱ category.ȱTheȱsystemȱalsoȱautomaticallyȱallocatesȱtheȱdeviceȱtheȱnextȱavailableȱ indexȱnumber.ȱȱ ȱ Toȱperformȱallocationȱviaȱtheȱkeypadȱusingȱaȱserialȱcode,ȱfollowȱthisȱprocedure:ȱ 1. GoȱtoȱtheȱEngineerȱmenuȱandȱselectȱProgrammingȱÆȱRadioȱDeviceȱÆȱAllocationȱ Æȱ2)ȱByȱCode.ȱEnterȱtheȱdevice’sȱ11ȱdigitȱserialȱcodeȱnumber.ȱȱ Page 3-4 AgilityȱEngineerȱManualȱȱ 2. ȱ Theȱsystemȱautomaticallyȱrecognizesȱtheȱdeviceȱandȱallocatesȱitȱtheȱnextȱavailableȱ indexȱnumber.ȱTheȱsystemȱwillȱsoundȱtheȱdeviceȱtypeȱthatȱhasȱbeenȱallocatedȱandȱ theȱplaceȱitȱhasȱbeenȱallocatedȱto.ȱ ȱ Toȱallocateȱzonesȱtoȱaȱpredefinedȱplaceȱviaȱtheȱkeypadȱfollowȱthisȱprocedure:ȱ ComparedȱtoȱtheȱRFȱandȱCodeȱallocationsȱmentionedȱbefore,ȱwhereȱtheȱwirelessȱelementsȱ areȱallocatedȱautomaticallyȱbyȱtheȱsystemȱtoȱtheȱfirstȱavailableȱplace,ȱwhenȱitȱcomesȱtoȱ zonesȱallocationȱtheȱAgilityȱalsoȱenablesȱtheȱallocationȱofȱzonesȱtoȱaȱpreȬdefinedȱlocation.ȱȱ 1. GoȱtoȱtheȱEngineerȱmenuȱandȱselectȱProgrammingȱÆȱRadioȱDeviceȱÆȱAllocationȱ Æȱ3)ȱZoneȱAllocation.ȱȱ 2. 3. 4. ȱ.ȱ Selectȱtheȱzoneȱnumberȱtoȱwhichȱyouȱwantȱtoȱassignȱtheȱdetectorȱandȱpressȱ Usingȱtheȱarrowȱkeysȱselectȱtheȱallocationȱmethod:ȱRFȱorȱCodeȱallocation.ȱ RFȱallocation:ȱSendȱaȱtransmissionȱfromȱtheȱdevice.ȱ(Seeȱtable:ȱTransmittersȱ writeȱmessageȱmethod)ȱ Codeȱallocation:ȱEnterȱtheȱdevice’sȱ11ȱdigitȱserialȱcodeȱnumber.ȱ Theȱsystemȱallocatesȱtheȱdetectorȱintoȱtheȱselectedȱindexȱnumber.ȱTheȱsystemȱwillȱ soundȱtheȱdeviceȱtypeȱthatȱhasȱbeenȱallocatedȱandȱtheȱplaceȱitȱhasȱbeenȱallocatedȱ to.ȱ Allocation using the Configuration Software Itȱisȱpossibleȱtoȱperformȱwirelessȱdeviceȱallocationȱviaȱtheȱconfigurationȱsoftwareȱinȱtwoȱ differentȱways:ȱRFȱAllocationȱorȱbyȱenteringȱtheȱdevice’sȱserialȱcode.ȱ ȱ ToȱperformȱRFȱallocationȱfromȱtheȱconfigurationȱsoftwareȱȱ 1. EstablishȱCommunicationȱbetweenȱtheȱmainȱunitȱandȱtheȱConfigurationȱsoftware.ȱ (ForȱmoreȱinformationȱreferȱtoȱtheȱConfigurationȱSoftwareȱManual)ȱ 2. OpenȱtheȱActivitiesȱ>ȱRadioȱDeviceȱAllocationȱscreen.ȱȱ 3. 4. Clickȱonȱtheȱ ȱbutton.ȱThisȱoperationȱwillȱsetȱtheȱmainȱunitȱtoȱLearnȱ mode.ȱTheȱfollowingȱmessageȱappears:ȱ ȱ Sendȱaȱtransmissionȱfromȱtheȱdevice.ȱ(Seeȱtableȱbelow)ȱ Page 3-5 ȱ 5. AgilityȱEngineerȱManualȱ Theȱmainȱunitȱwillȱacknowledgeȱtheȱtransmissionȱwithȱaȱsound.ȱWhenȱtheȱsystemȱ recognizesȱtheȱdeviceȱtheȱRadioȱDeviceȱAllocationȱscreenȱindicatesȱthatȱtheȱstatusȱ ofȱallocationȱhasȱbeenȱsuccessful.ȱTheȱserialȱnumber,ȱaccessoryȱtypeȱandȱtheȱindexȱ numberȱinformationȱwillȱbeȱdisplayed.ȱTheȱindexȱnumberȱisȱautomaticallyȱ addressedȱbyȱtheȱsystem.ȱ Note:ȱIfȱrequiredȱyouȱcanȱchangeȱtheȱindexȱnumberȱofȱtheȱwirelessȱdeviceȱbyȱselectingȱtheȱ requiredȱindexȱnumberȱandȱpressingȱtheȱȱȱ 6. Toȱallocateȱanȱotherȱwirelessȱdeviceȱclickȱonȱtheȱ stagesȱ3Ȭ7.ȱ ȱbuttonȱagain.ȱȱȱ ȱbuttonȱandȱthenȱrepeatȱ ȱ ToȱperformȱCodeȱallocationȱfromȱtheȱconfigurationȱsoftwareȱȱ 1. EstablishȱCommunicationȱbetweenȱtheȱmainȱunitȱandȱtheȱConfigurationȱsoftwareȱ byȱselectingȱCommunication>Connectȱfromȱtheȱmainȱmenu.ȱ(Forȱmoreȱ informationȱreferȱtoȱtheȱConfigurationȱSoftwareȱManual)ȱ 2. OpenȱtheȱRadioȱDeviceȱAllocationȱscreen.ȱInȱtheȱAllocationȱarea,ȱenterȱtheȱdeviceȇsȱ serialȱnumber.ȱȱ Note:ȱTheȱserialȱnumberȱcanȱbeȱfoundȱonȱtheȱdevice.ȱȱ 3. Selectȱtheȱwirelessȱdeviceȱindexȱnumber.ȱAutomaticȱmeansȱthatȱtheȱindexȱnumberȱ isȱautomaticallyȱaddressedȱbyȱtheȱsystem,ȱ 4. 5. Pressȱtheȱ ȱbutton.ȱ Theȱmainȱunitȱwillȱacknowledgeȱtheȱtransmissionȱwithȱaȱsound.ȱWhenȱtheȱsystemȱ recognizesȱtheȱdeviceȱtheȱRadioȱDeviceȱAllocationȱscreenȱindicatesȱthatȱtheȱstatusȱ ofȱallocationȱhasȱbeenȱsuccessful.ȱ Page 3-6 AgilityȱEngineerȱManualȱȱ ȱ Transmitters Write Message Method How to send a write message (transmission): Wireless Device Sending Write Message Detector/Contactsȱ Pressȱtheȱtamperȱswitchȱforȱ3ȱseconds.ȱ 2ȬWayȱKeypadȱ Pressȱbothȱkeysȱ leastȱ2ȱseconds.ȱ ȱandȱ simultaneouslyȱforȱatȱ 1ȬWayȱKeypadȱ Pressȱtheȱ 1ȬWayȱKeyȱfobȱ Pressȱthe±ȱbuttonȱforȱatȱleastȱ2ȱseconds.ȱ 2ȬWayȱRemoteȱControlȱ Pressȱbothȱkeysȱ leastȱ2ȱseconds.ȱ SmokeȱDetectorȱ Insertȱbattery.ȱWriteȱmessageȱisȱsendȱautomaticallyȱ withinȱ10ȱseconds.ȱ Sounderȱ Pressȱtheȱresetȱswitchȱonȱtheȱsounder.ȱAfterȱaȱsquawkȱisȱ soundedȱatȱtheȱsounderȱyouȱhaveȱ10ȱsecondsȱtoȱpressȱ onȱtheȱtamperȱswitchȱforȱatȱleastȱ3ȱseconds.ȱ Gas,ȱCOȱdetectorsȱ Pressȱtheȱtestȱbuttonȱforȱ3ȱseconds.ȱ 2ȱPanicȱButtonȱKeyȱfobȱ Pressȱbothȱbuttonsȱforȱatȱleastȱ7ȱseconds.ȱ ȱkeyȱtwice.ȱ ȱandȱ ȱsimultaneouslyȱforȱatȱ ȱ Deleting Wireless Accessories Deletingȱallȱwirelessȱdevicesȱcanȱbeȱdoneȱmanuallyȱ(fromȱtheȱmainȱunit)ȱorȱfromȱtheȱ Configurationȱsoftware.ȱ ȱ Toȱmanuallyȱdeleteȱallȱwirelessȱaccessoriesȱfromȱtheȱsystem:ȱ 1. PlaceȱDipȱSwitchȱ2ȱtoȱONȱposition.ȱ 2. Pressȱtheȱmainȱunitȱbuttonȱuntilȱitȱsounds.ȱ 3. ReplaceȱDipȱSwitchȱ2ȱtoȱOFFȱposition.ȱȱȱ ȱ ToȱdeleteȱaȱwirelessȱaccessoryȱfromȱtheȱWirelessȱKeypadȱ 1. GoȱtoȱtheȱEngineerȱmenusȱandȱselectȱProgrammingȱÆȱRadioȱDeviceȱÆȱ Modificationȱ 2. Selectȱtheȱdeviceȱcategoryȱ 3. GoȱtoȱParametersȱoption.ȱȱ 4. Selectȱtheȱdeviceȱindexȱnumberȱ 5. GoȱtoȱSerialȱnumberȱoptionȱandȱtypeȱinȱ000000000000.ȱ 6. Press .ȱTheȱdeviceȱwillȱbeȱdeletedȱ Page 3-7 ȱ AgilityȱEngineerȱManualȱ ȱ ToȱdeleteȱaȱwirelessȱaccessoryȱfromȱtheȱsystemȱviaȱtheȱConfigurationȱsoftware:ȱ 1. EstablishȱCommunicationȱbetweenȱtheȱmainȱunitȱandȱtheȱConfigurationȱsoftwareȱ (ForȱmoreȱinformationȱreferȱtoȱtheȱConfigurationȱSoftwareȱManual)ȱ 2. InȱtheȱRadioȱDeviceȱAllocationȱscreenȱinȱtheȱDeleteȱAccessoriesȱareaȱenterȱtheȱ deviceȇsȱserialȱcodeȱandȱclickȱtheȱDeleteȱbutton.ȱ ȱ ToȱdeleteȱallȱwirelessȱaccessoriesȱfromȱtheȱsystemȱviaȱtheȱConfigurationȱsoftware:ȱ 1. EstablishȱCommunicationȱbetweenȱtheȱmainȱunitȱandȱtheȱConfigurationȱsoftwareȱ byȱselectingȱCommunication>Connectȱfromȱtheȱmainȱmenu.ȱ(Forȱmoreȱ informationȱreferȱtoȱtheȱConfigurationȱSoftwareȱManual)ȱ 2. InȱtheȱRadioȱDeviceȱAllocationȱscreenȱinȱtheȱDeleteȱAccessoriesȱarea,ȱclickȱtheȱ DeleteȱAllȱbutton.ȱWhenȱallȱaccessoriesȱhaveȱbeenȱdeletedȱtheȱscreenȱwillȱ indicateȱthatȱdeletionȱhasȱbeenȱsuccessful.ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Page 3-8 AgilityȱEngineerȱManualȱ ȱ ȱ Chapter 4 Engineer Menus Theȱfollowingȱchapterȱdescribesȱtheȱparametersȱandȱprogrammingȱoptionsȱofȱtheȱsystemȱ andȱradioȱdevices.ȱTheseȱparametersȱcanȱbeȱprogrammedȱviaȱtheȱAgilityȱkeypadȱorȱtheȱ configurationȱsoftwareȱbyȱtheȱengineer.ȱȱ Note:ȱAȱnoteȱappearsȱnextȱtoȱtheȱparametersȱthatȱcanȱonlyȱbeȱprogrammedȱviaȱtheȱconfigurationȱsoftware.ȱ Forȱmoreȱinformationȱregardingȱtheȱinstallationȱandȱuseȱofȱtheȱconfigurationȱsoftwareȱreferȱtoȱtheȱ ConfigurationȱSoftwareȱmanual.ȱ Using the Agility keypad keys TheȱAgilityȱtwoȱwayȱkeypadȱcontainsȱthreeȱLEDȱindicators,ȱanȱLCDȱdisplayȱandȱaȱvarietyȱ ofȱkeys.ȱTheȱfollowingȱtableȱdescribesȱtheȱtypicalȱusesȱofȱtheȱkeysȱwhenȱinȱprogrammingȱ mode.ȱȱ ȱ Keys Description Theȱnumericalȱkeysȱonȱtheȱkeypadȱareȱusedȱasȱquickȱkeys,ȱaȱ numericalȱsequenceȱusedȱasȱaȱshortcutȱtoȱprogramȱanȱoption.ȱȱ ToȱprogramȱtheȱsystemȱusingȱQuickȱkeys:ȱ 1.ȱAccessȱtheȱengineerȱmenusȱ(seeȱbelow)ȱandȱselectȱtheȱrelevantȱmainȱmenuȱ option.ȱȱ 2.ȱPressȱtheȱquickȱkeysȱinȱsequenceȱtoȱlocateȱtheȱparameterȱandȱpressȱ .ȱ Numericalȱkeysȱareȱalsoȱusedȱtoȱinputȱtheȱnumericȱcodesȱthatȱmayȱ beȱrequiredȱforȱsetting,ȱunsetting,ȱorȱusedȱtoȱactivateȱspecificȱ functions.ȱ ExitsȱfromȱtheȱcurrentȱmenuȱandȱreturnsȱtoȱNormalȱOperationȱ modeȱ Terminatesȱcommandsȱandȱconfirmsȱdataȱtoȱbeȱstoredȱ Usedȱtoȱbrowseȱthroughȱtheȱmenu:ȱScrollsȱupȱaȱlistȱorȱmovesȱtheȱ cursorȱ ȱ Changesȱdataȱ Page 4-1 AgilityȱEngineerȱManualȱ ȱ Accessing the Engineer Menus ToȱaccessȱtheȱengineerȱmenusȱviaȱtheȱAgilityȱkeypad,ȱfollowȱthisȱprocedure:ȱ Pressȱtheȱ ȱkeyȱto activateȱtheȱkeypad.ȱ Enterȱtheȱengineerȱcodeȱ0132ȱ(defaultȱcode).ȱ Note:ȱIfȱtheȱAuthorizeȱEngineerȱsystemȱbitȱisȱdefinedȱasȱYES,ȱaȱGrandȱMasterȱcodeȱisȱrequiredȱtoȱ authorizeȱtheȱengineerȱtoȱenterȱtheȱprogrammingȱmode.ȱInȱthisȱcaseȱtheȱGrandȱMasterȱcodeȱ shouldȱbeȱenteredȱafterȱtheȱengineerȱcodeȱviaȱtheȱGrandȱMasterȱmenuȱÆȱActivitiesÆȱ AuthorizeȱEngineer.ȱȱ Theȱfollowingȱmenuȱappearsȱdisplayingȱaȱlistȱofȱallȱtheȱengineerȱmenus:ȱ 1) Programmingȱ 2) Testingȱ 3) Activitiesȱ 4) FollowȱMeȱ 5) Clockȱ 6) EventȱLogȱ 7) Macroȱ Usingȱtheȱ ȱkeysȱtoȱselectȱtheȱoptions.ȱȱ Programming Menu Allȱtheȱsystemȱparametersȱareȱprogrammedȱbyȱtheȱengineerȱviaȱtheȱprogrammingȱmenu.ȱȱ Afterȱaccessingȱtheȱengineerȱmenus,ȱselectȱtheȱ1)ȱProgrammingȱoption.ȱTheȱfollowingȱlistȱ appears:ȱ 1.ȱSystemȱ 2.ȱRadioȱDevicesȱȱ 3.ȱCodesȱȱ 4.ȱCommunicationȱȱ 5.ȱAudioȱ 6.ȱExitȱ 1. Programming: System Menu TheȱSystemȱmenuȱprovidesȱaccessȱtoȱparametersȱthatȱareȱusedȱforȱprogrammingȱ configurationȱsettingsȱapplicableȱtoȱtheȱentireȱsystem.ȱTheȱSystemȱmenuȱisȱdividedȱintoȱtheȱ followingȱsubȬmenus:ȱ 1.ȱTimersȱ 2.ȱControlsȱ 3.ȱLabelsȱ Page 4-2 AgilityȱEngineerȱManualȱ ȱ 4.ȱSoundsȱ 5.ȱSettingsȱ 6.ȱServiceȱInformationȱ 7.ȱFirmwareȱUpdateȱ 1.1 Timers TheȱTimersȱmenuȱcontainsȱparametersȱthatȱspecifyȱtheȱdurationȱofȱanȱaction.ȱ System: Timers Parameter Default Range Exit/EntryȱDelayȱ1ȱ ȱ ȱ ȱ Theȱamountȱofȱtimeȱbeforeȱtheȱsystemȱisȱset/unset.ȱUsuallyȱusedȱonȱfrontȱentranceȱdoor.ȱȱ ȱȱȱȱEntryȱDelayȱ1ȱ ȱ 30ȱsecȱ 0Ȭ255ȱsecȱ 45ȱsecȱ 0Ȭ255ȱsecȱ ȱ ȱ ȱȱȱȱDurationȱofȱentryȱdelayȱ1ȱbeforeȱtheȱsystemȱisȱunset.ȱ ȱȱȱȱExitȱDelayȱ1ȱ ȱ ȱȱȱȱDurationȱofȱexitȱdelayȱ1ȱbeforeȱtheȱsystemȱisȱset.ȱ Exit/EntryȱDelayȱ2ȱ ȱ Theȱamountȱofȱtimeȱbeforeȱtheȱsystemȱisȱset/unset.ȱUsuallyȱusedȱtoȱbackȱdoor.ȱ ȱȱȱȱEntryȱDelayȱ2ȱ ȱ 45ȱsecȱ 0Ȭ255ȱsecȱ 60ȱsecȱ 0Ȭ255ȱsecȱ ȱȱȱȱDurationȱofȱentryȱdelayȱ2ȱbeforeȱtheȱsystemȱisȱunset.ȱ ȱȱȱȱExitȱDelayȱ2ȱ ȱ ȱȱȱȱDurationȱofȱexitȱdelayȱ2ȱbeforeȱtheȱsystemȱisȱset.ȱ BellȱTimeoutȱ ȱ 04ȱminȱ 01Ȭ90ȱminȱ Durationȱofȱtheȱsounderȱduringȱalarm.ȱ BellȱDelayȱ ȱ 00ȱminȱ 00Ȭ90ȱminȱ Theȱtimeȱdelayȱbeforeȱaȱsounderȱsoundȱisȱproducedȱafterȱtriggeringȱanȱalarm.ȱȱ ACȱOffȱDelayȱ ȱ 30ȱminȱ 0Ȭ255ȱminȱ InȱtheȱcaseȱofȱaȱlossȱofȱACȱpower,ȱthisȱparameterȱspecifiesȱtheȱdelayȱperiodȱbeforeȱ reportingȱtheȱeventȱorȱoperatingȱtheȱProgrammableȱOutput.ȱIfȱtheȱdelayȱtimeȱisȱsetȱtoȱ zero,ȱthereȱwillȱbeȱnoȱdelayȱperiod.ȱ JammingȱTimeȱ Noneȱ None,ȱ10,ȱ20ȱorȱ30ȱsecȱ Specifiesȱtheȱperiodȱofȱtimeȱthatȱtheȱsystemȇsȱreceiverȱtoleratesȱunwantedȱradioȱ frequenciesȱcapableȱofȱblockingȱ(jamming)ȱsignalsȱproducedȱbyȱtheȱsystemȇsȱtransmitters.ȱ Onceȱtheȱspecifiedȱtimeȱisȱreached,ȱtheȱsystemȱsendsȱaȱreportȱcodeȱtoȱtheȱalarmȱreceivingȱ centerȱorȱactivatesȱaȱlocalȱsounder,ȱdependingȱonȱtheȱAudibleȱJammingȱsystemȱcontrol.ȱ NONE:ȱNoȱjammingȱwillȱbeȱdetectedȱorȱreported.ȱ Page 4-3 ȱ AgilityȱEngineerȱManualȱ ȱ System: Timers Parameter Default RXȱSupervisionȱ 3ȱhours 0Ȭ7ȱhoursȱ Range Specifiesȱhowȱoftenȱtheȱsystemȱexpectsȱtoȱgetȱaȱsignalȱfromȱtheȱsystemȇsȱtransmitters.ȱIfȱaȱ signalȱfromȱaȱzoneȱisȱnotȱreceivedȱduringȱtheȱspecifiedȱtimeȱtheȱzoneȱwillȱbeȱregardedȱasȱ lost,ȱtheȱsystemȱwillȱsendȱaȱreportȱcodeȱtoȱtheȱalarmȱreceivingȱcenter,ȱandȱtheȱsystemȱ statusȱwillȱbeȱȈNotȱReadyȈ.ȱ Notes:ȱ0ȱhoursȱdisablesȱsupervisionȱ ȱ Itȱisȱrecommendedȱtoȱsetȱtheȱsupervisionȱtimeȱtoȱaȱminimumȱofȱ3ȱhoursȱ TXȱSupervisionȱ 058ȱ 0Ȭ255ȱminȱ SpecifiesȱhowȱoftenȱaȱbiȬdirectionalȱwirelessȱdeviceȱgeneratesȱaȱsupervisionȱrequestȱtoȱtheȱ system.ȱ IfȱanȱaccessoryȱdoesȱnotȱgenerateȱaȱsupervisionȱsignalȱduringȱtheȱRXȱSupervisionȱtime,ȱ theȱsystemȱwillȱregardȱtheȱaccessoryȱasȱLost.ȱ Note:ȱTheȱdeviceȱwillȱgenerateȱtheȱsupervisionȱmessageȱaccordingȱtoȱtheȱtimeȱdefined.ȱ Important:ȱTheȱRXȱSupervisionȱtimeȱshouldȱbeȱhigherȱthanȱtheȱTxȱSupervisionȱtimeȱinȱorderȱtoȱeliminateȱ falseȱlostȱevent.ȱ RedialȱWaitȱȱ 30ȱsecȱ 0Ȭ255ȱsecȱ Theȱnumberȱofȱsecondsȱbetweenȱattemptsȱatȱredialingȱtheȱsameȱphoneȱnumber.ȱȱ AppliesȱtoȱbothȱtheȱARCȱRetriesȱandȱFMȱRetriesȱparameters.ȱȱ Note:ȱUsedȱforȱbothȱPSTNȱandȱGSM.ȱ Moreȱ ȱ ȱ ȱȱȱȱSwingerȱLimitȱShutdownȱ 00ȱ 0Ȭ15ȱtimesȱ Aȱswingerȱisȱaȱrepeatedȱviolationȱofȱtheȱsameȱzone,ȱoftenȱresultingȱinȱaȱnuisanceȱalarmȱ andȱusuallyȱdueȱtoȱaȱmalfunction,ȱanȱenvironmentalȱproblem,ȱorȱtheȱincorrectȱ installationȱofȱaȱdetectorȱorȱsensor.ȱ Thisȱparameterȱspecifiesȱtheȱnumberȱofȱviolationsȱofȱtheȱsameȱzoneȱreportedȱduringȱaȱ singleȱsetȱperiod,ȱbeforeȱtheȱzoneȱisȱautomaticallyȱomitted.ȱ toȱdisablesȱtheȱswingerȱshutdownȱ ȱȱȱȱNoȱActivityȱ 00ȱ 0Ȭ99ȱhoursȱ Determinesȱtheȱtimeȱlimitȱforȱreceptionȱofȱsignalsȱfromȱsensorsȱusedȱtoȱmonitorȱtheȱ activityȱofȱsick,ȱelderlyȱorȱdisabledȱpeople.ȱIfȱnoȱsignalȱisȱreceivedȱfromȱaȱzoneȱdefinedȱ withȱtheȱȈNoȱActivityȈȱfeatureȱȱatȱleastȱonceȱwithinȱtheȱdefinedȱtimeȱlimit,ȱaȱ“noȬ activity”ȱalertȱcanȱbeȱsendȱtoȱFollowȱMeȱdestination,ȱaȱlocalȱmessageȱcanȱbeȱheardȱandȱaȱ reportȱtoȱȱARCȱcanȱbeȱdefinedȱtoȱbeȱsend.ȱȱ Options:ȱ0ȱ=thisȱparameterȱisȱinactive.ȱ Page 4-4 AgilityȱEngineerȱManualȱ ȱ ȱ System: Timers Parameter Default Range ȱȱȱȱLastȱExitȱSoundȱ 00ȱ 0Ȭ255ȱsecondsȱ DefinesȱtheȱlastȱsecondsȱofȱtheȱExitȱTimeȱthatȱtheȱbeepȱsoundȱwillȱchangeȱ(mainȱunitȱ andȱkeypads),ȱindicatingȱtoȱtheȱuserȱthatȱExitȱTimeȱisȱaboutȱtoȱend.ȱ 1.2 Controls TheȱControlȱmenuȱcontainsȱparametersȱthatȱcontrolȱspecificȱsystemȱoperations.ȱ System: Controls Parameter Default Basicȱprogrammingȱ QuickȱSetȱ ȱ YESȱ YES:ȱEliminatesȱtheȱneedȱforȱaȱuserȱcodeȱwhenȱsettingȱ(Fullȱorȱpartial)ȱtheȱsystemȱbyȱaȱ keypadȱorȱ2Ȭwayȱremoteȱcontrol.ȱ NO:ȱAȱvalidȱuserȱcodeȱisȱrequiredȱforȱsettingȱusingȱaȱkeypadȱorȱremoteȱcontrol.ȱ AllowȱOmitȱ ȱ YESȱ YES:ȱPermitsȱzoneȱomittingȱbyȱauthorizedȱsystemȱusersȱafterȱenteringȱaȱvalidȱuserȱcode.ȱ NO:ȱZoneȱomittingȱisȱNOTȱpermitted.ȱ QuickȱStatusȱ YESȱ YES:ȱAȱuserȱcodeȱisȱnotȱrequiredȱbeforeȱpressingȱtheȱstatusȱkey/buttonȱonȱyourȱwirelessȱ keypadȱorȱbiȬdirectionalȱremoteȱcontrol.ȱ NO:ȱAȱuserȱcodeȱisȱrequiredȱtoȱactivateȱtheȱstatusȱkey.ȱ FalseȱCodeȱFaultȱ YESȱ YES:ȱAȱfalseȱcodeȱreportȱisȱsentȱtoȱtheȱalarmȱreceivingȱcenterȱafterȱfiveȱsuccessiveȱ attemptsȱatȱsettingȱorȱunsettingȱinȱwhichȱanȱincorrectȱuserȱcodeȱisȱentered.ȱNoȱalarmȱ soundsȱatȱtheȱpremises,ȱbutȱaȱfaultȱindicationȱappears.ȱTheȱwirelessȱkeypadȱwillȱbeȱlockedȱ forȱ30ȱminutes.ȱȱ NO:ȱAȱlocalȱalarmȱisȱsoundedȱatȱtheȱpremises.ȱ SounderȱSquawkȱ ȱ YESȱ YES:ȱSettingȱorȱunsettingȱtheȱsystemȱusingȱaȱremoteȱcontrol,ȱwirelessȱkeypadȱorȱaȱkeyȬ switchȱȱproducesȱaȱbriefȱȈchirpȈȱandȱactivatesȱtheȱstrobeȱasȱfollows:ȱ x Oneȱchirpȱindicatesȱtheȱsystemȱisȱsetȱ(alsoȱwhenȱsettingȱwithȱaȱkeypad).ȱ x Twoȱchirpsȱindicateȱtheȱsystemȱisȱunset.ȱ x Fourȱchirpsȱindicateȱtheȱsystemȱisȱunsetȱafterȱanȱalarm.ȱ NO:ȱNoȱȈchirpȈȱisȱproduced.ȱ Page 4-5 AgilityȱEngineerȱManualȱ ȱ System: Controls Parameter AudibleȱPanicȱ Default ȱ NOȱ YES:ȱTheȱsoundersȱoperateȱwhenȱaȱȈPoliceȱAlarmȈȱisȱinitiatedȱatȱtheȱkeypadȱ(ifȱdefined),ȱ theȱremoteȱcontrolȱorȱwhenȱaȱpanicȱzoneȱisȱactivated.ȱ NO:ȱNoȱsounderȱoperationȱoccursȱduringȱaȱȈPanicȱAlarm,Ȉȱmakingȱtheȱalarmȱtrulyȱ ȈsilentȈȱ(SilentȱPanic).ȱ Note:ȱTheȱsystemȱalwaysȱtransmitsȱaȱpanicȱreportȱtoȱtheȱalarmȱreceivingȱcenter.ȱ ȱ BuzzerȱÆȱȱBellȱ NOȱ YES:ȱIfȱanȱalarmȱoccursȱwhenȱtheȱsystemȱisȱsetȱinȱtheȱPartȱSetȱmode,ȱaȱbuzzerȱsoundsȱforȱ 15ȱsecondsȱbeforeȱtheȱsoundersȱoperate.ȱ NO:ȱAnȱalarmȱinȱtheȱPartȱSetȱmodeȱcausesȱsoundersȱtoȱoperateȱsimultaneously.ȱ AudibleȱJammingȱ NOȱ RelatesȱtoȱtheȱJammingȱTimeȱparameter.ȱ YES:ȱOnceȱtheȱspecifiedȱtimeȱisȱreached,ȱtheȱsystemȱactivatesȱtheȱsounderȱandȱsendsȱaȱ reportȱcodeȱtoȱtheȱalarmȱreceivingȱcenter.ȱȱ NO:ȱOnceȱtheȱspecifiedȱtimeȱisȱreachedȱtheȱsoundersȱdoȱnotȱoperate.ȱ ExitȱBeepsȱatȱPartȱSetȱ YESȱ DeterminesȱwhetherȱtheȱsystemȱwillȱsoundȱbeepsȱduringȱexitȱtimeȱinȱPartȱSetting.ȱ YES:ȱExitȱbeepsȱwillȱsoundȱ NO:ȱExitȱbeepsȱwillȱnotȱsoundȱ ForcedȱDeviceȱSettingȱ YESȱ YES:ȱSettingȱaȱpartition,ȱusingȱaȱremoteȱcontrolȱorȱkeyȬswitchȱcanȱbeȱperformedȱwithȱ violatedȱ(notȱready)ȱzonesȱinȱtheȱsystem.ȱȱAnyȱviolatedȱ(notȱready)ȱzone(s)ȱinȱtheȱ partitionȱwillȱbeȱomittedȱautomatically.ȱTheȱpartitionȱisȱthenȱȈforceȱset,Ȉȱandȱallȱintactȱ zonesȱareȱcapableȱofȱproducingȱanȱalarm.ȱ NO:ȱTheȱpartitionȱcannotȱbeȱsetȱuntilȱallȱviolatedȱ(notȱready)ȱzonesȱareȱsecured.ȱ Page 4-6 AgilityȱEngineerȱManualȱ ȱ ȱ System: Controls Parameter Default SetȱPreȬwarningȱ YESȱ RelatedȱtoȱautoȱSet/Unsetȱoperation.ȱ YES:ȱForȱanyȱpartition(s)ȱsetȱupȱforȱAutoȱSetting,ȱanȱaudibleȱExitȱDelayȱ(warning)ȱ countdownȱwillȱcommenceȱ4.25ȱminutesȱpriorȱtoȱtheȱautomaticȱSetting.ȱDuringȱthisȱ period,ȱExitȱDelayȱbeepsȱwillȱbeȱheard.ȱȱ YouȱcanȱenterȱaȱvalidȱUserȱCodeȱatȱanyȱtimeȱduringȱtheȱcountdownȱtoȱdelayȱtheȱ partitionȇsȱautomaticȱSettingȱbyȱ45ȱminutes.ȱ WhenȱanȱȈAutoȬSetȈȱpartitionȱisȱunset,ȱasȱdescribedȱabove,ȱitȱcanȱnoȱlongerȱbeȱ automaticallyȱsetȱduringȱtheȱcurrentȱday.ȱ Theȱextendedȱ4.25ȱminutesȱwarningȱdoesȱnotȱapplyȱtoȱautomaticȱPartialȱSetting.ȱ NO:ȱAutoȱSettingȱforȱanyȱprogrammedȱpartition(s)ȱtakesȱplaceȱatȱtheȱdesignatedȱtime.ȱ TheȱprogrammedȱExitȱDelayȱperiodȱandȱanyȱaudibleȱsignalȱoccurȱasȱexpected.ȱ DefaultȱEnableȱ YESȱ ThisȱoptionȱȱcontainsȱparametersȱthatȱrelateȱtoȱwhatȱhappensȱtoȱtheȱEngineer,ȱSubȬ EngineerȱandȱGrandȱMasterȱcodesȱifȱtheȱMainȱPanelȇsȱDEFAULTȱDipȱSwitchȱ2ȱisȱinȱplaceȱ whenȱpowerȱtoȱtheȱMainȱPanelȱisȱswitchedȱoffȱandȱthenȱon.ȱForȱmoreȱinformationȱ regardingȱpanelȱdefaultsȱreferȱtoȱChapterȱ2,ȱDipȱSwitchȱSetting,ȱseeȱexplanationȱofȱDipȱ Switchȱ2.ȱ YES:ȱTheȱEngineer,ȱSubȬEngineerȱandȱGrandȱMasterȱcodesȱwillȱreturnȱtoȱtheȱoriginal,ȱ factoryȱdefaultȱvalues.ȱȱ NO:ȱTheȱEngineer,ȱSubȬEngineerȱandȱGrandȱMasterȱcodesȱwillȱNOTȱreturnȱtoȱtheȱ original,ȱfactoryȱdefaultȱvaluesȱbyȱanȱunauthorizedȱuser.ȱȱ MainȱButton:ȱStatusȬY/TalkȬNȱ YESȱ TheȱAgilityȱenablesȱtheȱARCȱtoȱperformȱListenȬInȱandȱTalkȱfunctionsȱinȱorderȱtoȱverifyȱaȱ causeȱofȱeventȱorȱtoȱguideȱsomeoneȱinȱdistress.ȱTheȱMainȱButton:ȱStatusȬY/TalkȬNȱ parameterȱdeterminesȱtheȱfunctionȱofȱtheȱbuttonȱonȱtheȱsurfaceȱofȱtheȱmainȱunitȱtoȱenableȱ ListenȬInȱandȱTalk.ȱ YES:ȱStatusȱbuttonȱ–ȱTheȱsystemȱwillȱrelayȱtheȱsystemȱstatus.ȱ NO:ȱServiceȱcallȱbuttonȱ–ȱTheȱsystemȱdialsȱtheȱARCȱtoȱestablishȱ2Ȭwayȱcommunication.ȱ QuickȱLearnȱ YESȱ Enablesȱtheȱbuttonȱonȱtheȱsurfaceȱofȱtheȱmainȱunitȱtoȱperformȱquickȱallocationȱofȱwirelessȱ devices.ȱ(SeeȱChapterȱ3ȱSystemȱDeviceȱAllocation:ȱManualȱSetup)ȱ YES:ȱQuickȱlearnȱmodeȱisȱenabled.ȱLongȱpressȱonȱtheȱmainȱunitȱbuttonȱwillȱstartȱLearnȱ mode.ȱTheȱLEDsȱonȱtheȱmainȱunitȱwillȱstartȱflashingȱoneȱafterȱtheȱotherȱ NO:ȱQuickȱlearningȱmodeȱisȱdisabled.ȱTheȱmainȱunitȱbuttonȱisȱnotȱinȱLearnȱmode.ȱ Page 4-7 AgilityȱEngineerȱManualȱ ȱ System: Controls Parameter Default Advancedȱprogrammingȱ Areaȱȱ NOȱ ChangesȱtheȱsystemȱoperationȱtoȱAreaȱinsteadȱofȱPartition,ȱwhichȱthenȱchangesȱonlyȱtheȱ operationȱofȱaȱcommonȱzone.ȱ YES:ȱWhenȱselected,ȱtheȱfollowingȱpointsȱareȱrelevant:ȱ x Aȱcommonȱzoneȱwillȱbeȱsetȱafterȱanyȱpartitionȱisȱset.ȱ x Aȱcommonȱzoneȱwillȱbeȱunsetȱonlyȱwhenȱallȱpartitionsȱareȱunset.ȱ NO:ȱWhenȱselected,ȱtheȱfollowingȱpointsȱareȱrelevant:ȱ x Aȱcommonȱzoneȱwillȱbeȱsetȱonlyȱwhenȱallȱpartitionsȱareȱset.ȱȱ x Aȱcommonȱzoneȱwillȱbeȱunsetȱwhenȱanyȱpartitionȱisȱunset.ȱ GlobalȱFollowerȱ NOȱ YES:ȱSpecifiesȱthatȱallȱzonesȱ(thatȱareȱprogrammedȱtoȱfollowȱanȱExit/EntryȱDelayȱtime)ȱ willȱfollowȱtheȱExit/EntryȱDelayȱtimeȱofȱanyȱsetȱpartition.ȱ NO:ȱSpecifiesȱthatȱallȱzonesȱ(thatȱareȱprogrammedȱtoȱfollowȱanȱEntryȱDelayȱtime)ȱwillȱ followȱtheȱEntryȱDelayȱtimeȱofȱonlyȱtheȱpartitionsȱtoȱwhichȱtheyȱareȱassigned.ȱ Summer/Winterȱȱ NOȱ YES:ȱTheȱsystemȱautomaticallyȱsetsȱitsȱtimeȱofȱdayȱclockȱoneȱhourȱaheadȱinȱtheȱspringȱ(onȱ theȱlastȱSundayȱinȱMarch)ȱandȱoneȱhourȱbackȱinȱtheȱAutumnȱ(onȱtheȱlastȱSundayȱinȱ October).ȱ NO:ȱNoȱautomaticȱtimeȱaccommodationȱisȱmade.ȱ 24ȱHourȱOmitȱ NOȱ YES:ȱItȱisȱpossibleȱforȱtheȱuserȱtoȱomitȱaȱ24Ȭhourȱzone.ȱ NO:ȱItȱisȱnotȱpossibleȱforȱtheȱuserȱtoȱomitȱaȱ24Ȭhourȱzone.ȱ TamperȱResetȱ NOȱȱ YES:ȱItȱisȱnecessaryȱtoȱenterȱtheȱEngineerȱCodeȱtoȱresetȱaȱTamperȱalarm.ȱTherefore,ȱ resettingȱaȱTamperȱalarmȱrequiresȱtheȱinterventionȱofȱtheȱalarmȱcompany.ȱHowever,ȱtheȱ systemȱcanȱstillȱbeȱset.ȱ NO:ȱCorrectingȱtheȱproblemȱresetsȱaȱTamperȱalarm,ȱrequiringȱnoȱalarmȱcompanyȱhelp.ȱ EngineerȱResetȱ NOȱȱ YES:ȱItȱisȱnecessaryȱtoȱenterȱtheȱEngineerȱCodeȱtoȱresetȱanȱalarmedȱpartitionȱafterȱitȱhasȱ beenȱunset.ȱThisȱrequiresȱtheȱinterventionȱofȱtheȱalarmȱcompany.ȱȱ Note:ȱBeforeȱtheȱReadyȱLEDȱcanȱlightȱallȱzonesȱwithinȱtheȱpartitionȱmustȱbeȱsecured.ȱ NO:ȱOnceȱanȱalarmedȱpartitionȱisȱresetȱtheȱReadyȱLEDȱlightsȱwhenȱallȱzonesȱareȱsecured.ȱ Page 4-8 AgilityȱEngineerȱManualȱ ȱ ȱ System: Controls Parameter Default EngineerȱTamperȱ NOȱ YES:ȱAfterȱaȱTamperȱalarm,ȱtheȱsystemȱisȱnotȱreadyȱtoȱset.ȱThisȱrequiresȱtheȱinterventionȱ ofȱtheȱalarmȱcompany.ȱ NO:ȱAfterȱaȱTamperȱalarmȱisȱrestoredȱtheȱsystemȱisȱready.ȱ LowȱBatteryȱȱSetȱ YESȱ YES:ȱAllowsȱsettingȱofȱtheȱsystemȱwhenȱaȱlowȱbatteryȱconditionȱisȱdetectedȱinȱtheȱmainȱ unit.ȱ NO:ȱSettingȱtheȱsystemȱisȱdisabledȱwhenȱaȱlowȱbatteryȱconditionȱisȱdetected.ȱ SounderȱPreȬAlarmȱ ȱ NOȱ SpecifiesȱifȱtheȱsystemȱwillȱsendȱaȱpreȬalarmȱmessageȱtoȱtheȱsounderȱwhileȱanȱentryȱdelayȱ starts.ȱȱ YES:ȱTheȱsystemȱsendsȱaȱpreȬalarmȱsignalȱtoȱtheȱsounderȱatȱtheȱbeginningȱofȱtheȱentryȱ delay.ȱIfȱtheȱsounderȱdoesȱnotȱreceiveȱaȱcancellationȱsignalȱfromȱtheȱsystemȱatȱtheȱendȱofȱ theȱentryȱtime,ȱtheȱsounderȱgoesȱintoȱalarm.ȱȱ NO:ȱPreȬAlarmȱdisabledȱȱȱ Bellȱ30/10ȱ NOȱ YES:ȱTheȱsoundersȱceaseȱtoȱsoundȱforȱ10ȱsecondsȱafterȱeachȱ30ȱsecondsȱofȱoperation.ȱ NO:ȱTheȱsoundersȱoperateȱwithoutȱinterruption.ȱ FireȱAlarmȱPatternȱ NOȱ YES:ȱDuringȱaȱfireȱalarm,ȱtheȱsoundersȱproduceȱaȱpatternȱofȱ3ȱshortȱburstsȱfollowedȱbyȱaȱ briefȱpause.ȱ NO:ȱDuringȱaȱfireȱalarm,ȱtheȱflowȱofȱsoundsȱproducedȱbyȱtheȱsounderȱisȱaȱpatternȱofȱ2ȱ secondsȱON,ȱthenȱ2ȱsecondsȱOFF.ȱ IMQȱ NOȱ YES:ȱCausesȱtheȱfollowingȱparametersȱtoȱfunctionȱasȱfollows:ȱ AutoȱSetȱOmit:ȱIfȱthereȱisȱanȱopenȱzoneȱduringȱtheȱAutoȱSetȱprocess,ȱtheȱsystemȱwillȱ beȱset,ȱandȱaȱsilentȱalarmȱwillȱbeȱactivatedȱ(unlessȱtheȱopenȱzoneȱisȱclosed).ȱ Aȱprogrammingȱoutputȱdefinedȱasȱ“AutoȱSetȱAlarm”ȱisȱactivated.ȱ Aȱprogrammingȱoutputȱdefinedȱasȱ“ZoneȱLossȱAlarm”ȱisȱactivatedȱȱ NO:ȱCausesȱtheȱfollowingȱparametersȱtoȱfunctionȱasȱfollows:ȱ AutoȱSetȱOmit:ȱIfȱtheȱAutoȱSetȱprogrammingȱsetsȱtheȱsystemȱandȱthereȱisȱanȱopenȱ zoneȱduringȱtheȱautoȱset,ȱtheȱsystemȱwillȱomitȱtheȱopenȱzonesȱandȱsetȱtheȱsystem.ȱ Aȱprogrammingȱoutputȱdefinedȱasȱ“AutoȱSetȱAlarm”ȱisȱdeactivated.ȱ Aȱprogrammingȱoutputȱdefinedȱasȱ“ZoneȱLossȱAlarm”ȱisȱdeactivated.ȱ Note:ȱtheȱIMQȱfeatureȱisȱforȱtheȱItalianȱmarket.ȱ Page 4-9 AgilityȱEngineerȱManualȱ ȱ System: Controls Parameter Default DisableȱIncomingȱCallȱ ȱ NOȱ Thisȱparameterȱisȱusedȱtoȱdisableȱallȱincomingȱcallsȱtryingȱtoȱcomeȱinȱviaȱtheȱvoiceȱ channelȱ(PSTNȱorȱGSM).ȱȱ YES:ȱIncomingȱcallsȱfromȱvoiceȱchannelȱareȱdisabled.ȱ NO:ȱIncomingȱcallsȱfromȱvoiceȱchannelȱareȱenabled.ȱ Note:ȱIncomingȱdataȱcallȱviaȱtheȱGSMȱdataȱchannelȱisȱstillȱenabled.ȱ Communicationȱȱ ARCȱEnableȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱYESȱ YES:ȱEnablesȱcommunicationȱwithȱtheȱCentralȱStationȱtoȱreportȱalarms,ȱfault,ȱandȱ supervisoryȱevents.ȱ NO:ȱNoȱcommunicationȱwithȱtheȱCentralȱStationȱisȱpossible.ȱChooseȱNOȱforȱinstallationsȱ thatȱareȱNOTȱmonitoredȱbyȱaȱCentralȱStation.ȱ ConfigurationȱSoftwareȱEnableȱ ȱ YESȱ YES:ȱEnablesȱcommunicationȱbetweenȱtheȱalarmȱcompanyȱandȱtheȱsystemȱusingȱtheȱ Configurationȱsoftware.ȱThisȱenablesȱmodifyingȱanȱinstallationȇsȱconfiguration,ȱobtainingȱ statusȱinformation,ȱandȱissuingȱMainȱPanelȱcommands,ȱallȱfromȱaȱremoteȱlocation.ȱ NO:ȱDisablesȱcommunication,ȱasȱdetailedȱabove.ȱ FMȱEnableȱ ȱ YESȱ YES:ȱEnablesȱFollowȬMeȱcommunication.ȱ IfȱbothȱtheȱARCȱphonesȱandȱtheȱFMȱphonesȱareȱdefined,ȱtheȱsystemȱwillȱfirstȱcallȱtheȱARCȱ phonesȱandȱthenȱtheȱFMȱphones.ȱ NO:ȱDisablesȱFollowȬMeȱcommunication.ȱ ENȱ50131ȱprogrammingȱ AuthorizeȱEngineerȱ NOȱ ThisȱoptionȱlimitsȱtheȱEngineerȱandȱSubȬengineerȱauthorizationȱtoȱaccessȱtheȱ programmingȱmenu.ȱ YES:ȱAȱGrandȱMasterȱcodeȱisȱrequiredȱtoȱauthorizeȱtheȱengineerȱtoȱenterȱtheȱ programmingȱmodeȱforȱ1ȱhour.ȱ NO:ȱTheȱEngineerȱdoesȱnotȱneedȱanȱauthorizationȱcode.ȱ Page 4-10 AgilityȱEngineerȱManualȱ ȱ ȱ System: Controls Parameter Default OverrideȱFaultȱȱ YESȱ Specifiesȱifȱtheȱsystem/partitionȱcanȱbeȱsetȱwhenȱthereȱisȱaȱfaultȱinȱtheȱsystem.ȱ YES:ȱTheȱsystemȱwillȱsetȱevenȱifȱthereȱisȱaȱfaultȱinȱtheȱsystem.ȱ NO:ȱWhenȱtheȱuserȱstartsȱtheȱsettingȱprocessȱandȱthereȱisȱaȱsystemȬfault,ȱtheȱuserȱmustȱ confirmȱthatȱheȱisȱawareȱofȱallȱfaultsȱbeforeȱcontinuingȱwithȱtheȱSettingȱprocess.ȱȱ ThisȱisȱdoneȱviaȱtheȱUserȱmenuÆActivitiesÆOmitȱFault.ȱ Theȱsystemȱwillȱnotȱsetȱduringȱforcedȱsettingȱifȱaȱfaultȱoccurredȱinȱtheȱsystemȱ NOȱ RestoreȱAlarmȱ YES:ȱTheȱuserȱmustȱconfirmȱthatȱheȱisȱawareȱthatȱalarmȱoccurredȱinȱtheȱsystemȱbeforeȱ resettingȱtheȱsystem.ȱTheȱsystemȱwillȱbeȱinȱȈNotȱReadyȈȱstatusȱuntilȱheȱconfirmsȱtheȱ alarm.ȱThisȱisȱdoneȱviaȱtheȱUserȱmenuÆActivitiesÆAdvancedÆRestoreȱAlarm.ȱ NO:ȱTheȱuserȱdoesȱnotȱneedȱtoȱconfirmȱtheȱalarmȱbeforeȱresettingȱtheȱsystem.ȱ NOȱ MandatoryȱEventȱLogȱ YES:ȱOnlyȱmandatoryȱeventsȱ(specifiedȱinȱtheȱENȱstandard)ȱwillȱbeȱdisplayedȱinȱtheȱ EventȱLog.ȱȱ NO:ȱAllȱtheȱeventsȱwillȱbeȱdisplayedȱinȱtheȱEventȱLog.ȱ NOȱ RestoreȱFaultsȱ YES:ȱTheȱuserȱmustȱmanuallyȱconfirmȱtheȱrestoralȱofȱeachȱfaultȱtoȱaȱnormalȱcondition.ȱ ThisȱisȱdoneȱviaȱtheȱUserȱmenuȱÆȱActivitiesȱÆȱAdvancedȱÆȱRestoreȱFaults.ȱ NO:ȱTheȱrestoralȱreportȱofȱeachȱfaultȱisȱautomaticȱ.ȱ YESȱ ExitȱAlarmȱ YES:ȱAȱviolatedȱzoneȱoutsideȱtheȱexitȱrouteȱwillȱgenerateȱanȱalarmȱduringȱtheȱexitȱtime.ȱAȱ reportȱtoȱtheȱalarmȱreceivingȱcenterȱforȱsettingȱtheȱsystemȱisȱsentȱatȱtheȱbeginningȱofȱtheȱ settingȱprocedure.ȱ NO:ȱAȱviolatedȱzoneȱoutsideȱtheȱexitȱrouteȱwillȱcancelȱtheȱsettingȱprocess.ȱAȱreportȱtoȱtheȱ alarmȱreceivingȱcenterȱisȱsendȱatȱtheȱendȱofȱaȱsuccessfulȱsettingȱprocedure.ȱ EntryȱDelayedȱAlarmȱ NOȱ ThisȱfeatureȱisȱusedȱtoȱreduceȱfalseȱalarmȱreportsȱtoȱtheȱARC.ȱȱ YES:ȱTheȱreportȱtoȱtheȱARCȱandȱtheȱsounderȱalarmȱwillȱbeȱdelayedȱforȱ30ȱsecondsȱorȱuntilȱ theȱendȱofȱtheȱpredefinedȱentryȱdelayȱ(theȱshorterȱtimeȱofȱtheȱtwo)ȱfollowingȱaȱviolationȱofȱ aȱzoneȱoutsideȱtheȱentryȱroute.ȱȱȱ NO:ȱAȱviolatedȱzoneȱoutsideȱtheȱentryȱrouteȱwillȱgenerateȱanȱalarmȱduringȱtheȱ entryȱtimeȱandȱaȱreportȱwillȱbeȱsentȱtoȱtheȱARC. Page 4-11 AgilityȱEngineerȱManualȱ ȱ System: Controls Parameter Default NOȱ 20ȱMinutesȱSignalȱ YES:ȱPriorȱtoȱsettingȱtheȱsystem,ȱtheȱsystemȱwillȱcheckȱforȱzonesȱthatȱdidȱnotȱsendȱaȱsignalȱ forȱmoreȱthanȱ20ȱminutes.ȱTheseȱzonesȱwillȱbeȱregardedȱasȱnotȱready.ȱAȱpartitionȱassignedȱ withȱaȱnotȱreadyȱzoneȱcannotȱbeȱset.ȱȱ NO:ȱPriorȱtoȱsetting,ȱtheȱsystemȱwillȱnotȱcheckȱwhetherȱaȱzoneȱdidȱnotȱsendȱaȱsignalȱforȱ moreȱthanȱ20ȱminutes.ȱ NOȱ Attenuationȱ YES:ȱTheȱAgilityȱreceiverȱwillȱbeȱattenuatedȱbyȱ6ȱdBȱduringȱtheȱcommunicationȱtest.ȱ NO:ȱTheȱAgilityȱreceiverȱworksȱinȱnormalȱoperationȱmode.ȱ DD243ȱprogrammingȱ YESȱ OmitȱExit/Entryȱ YES:ȱItȱisȱpossibleȱforȱtheȱuserȱtoȱomitȱanȱExit/Entryȱzone.ȱ NO:ȱAnȱExit/Entryȱzoneȱcannotȱbeȱomitted.ȱ NOȱ EntryȱDisableȱ YES:ȱTheȱalarmȱconfirmationȱprocessȱwillȱbeȱdisabledȱwhenȱtheȱentryȱtimeȱstarts.ȱ NO:ȱTheȱalarmȱconfirmationȱprocessȱwillȱstartȱwhenȱtheȱentryȱtimeȱstarts.ȱ NOȱ RouteȱDisableȱ YES:ȱTheȱpanelȱdisablesȱtheȱentryȱrouteȱzonesȱ(EX/EN,ȱEXȱ(OP)/EN,ȱfollowersȱandȱFinalȱ Exit)ȱfromȱparticipatingȱinȱtheȱalarmȱconfirmationȱprocessȱwhenȱtheȱentryȱtimeȱstarts.ȱ Note:ȱSequentialȱconfirmationȱcanȱstillȱbeȱestablishedȱfromȱtwoȱconfirmedȱzones,ȱlocatedȱoffȱtheȱentryȱroute.ȱ NO:ȱTheȱentryȱrouteȱzonesȱwillȱparticipateȱinȱtheȱalarmȱconfirmationȱprocessȱwhenȱtheȱ entryȱtimeȱstarts.ȱ NOȱ EngineerȱResetȱConfirmationȱ YES:ȱAnȱengineerȱresetȱconfirmationȱisȱrequiredȱinȱorderȱtoȱresetȱtheȱsystemȱafterȱaȱ confirmedȱalarm.ȱTheȱsystemȱcannotȱbeȱsetȱuntilȱanȱEngineerȱResetȱConfirmationȱisȱ performed.ȱTheȱresetȱcanȱbeȱdoneȱbyȱenteringȱtheȱAntiȱcodeȱorȱenteringȱtheȱinstallationȱ modeȱorȱbyȱperformingȱaȱ“Engineerȱreset”ȱfromȱtheȱkeypad.ȱ NO:ȱAnyȱmeansȱcanȱbeȱusedȱtoȱsetȱorȱunsetȱtheȱsystemȱ(keypad,ȱremoteȱphoneȱoperationȱ etc.).ȱ Page 4-12 AgilityȱEngineerȱManualȱ ȱ ȱ System: Controls Parameter Default NOȱ KeyȱSwitchȱLockȱ YES:ȱOnlyȱaȱLatchedȱKeyȱSwitchȱzoneȱcanȱsetȱorȱunsetȱtheȱsystem.ȱ Note:ȱWhenȱtheȱsystemȱhasȱmoreȱthanȱ1ȱzoneȱdefinedȱasȱLatchȱKeyȱSwitch,ȱtheȱset/unsetȱoperationȱwillȱ occurȱonlyȱafterȱallȱtheseȱzonesȱareȱsetȱorȱunset.ȱ NO:ȱAnyȱmeansȱcanȱbeȱusedȱtoȱsetȱorȱunsetȱtheȱsystemȱ(keypad,ȱremoteȱphoneȱoperationȱ etc.).ȱ NOȱ EntryȱUnsetȱ Determinesȱifȱtheȱsystem’sȱunsettingȱdependsȱonȱtheȱentryȱtime.ȱ YES:ȱOnlyȱaȱremoteȱcontrolȱcanȱunsetȱtheȱsystemȱduringȱentryȱtime.ȱȱ Note:ȱTheȱsystemȱcanȇtȱbeȱunsetȱwithȱaȱremoteȱcontrolȱwhileȱtheȱsystemȱisȱset.ȱ NO:ȱTheȱsystemȱcanȱbeȱunsetȱduringȱanyȱtimeȱusingȱanyȱunsettingȱdevice.ȱ ȱ CPȬ01ȱprogrammingȱ NOȱ ExitȱRestartȱ Thisȱparameterȱisȱusedȱtoȱdefineȱifȱanȱexitȱtimeȱshallȱrestartȱoneȱadditionalȱtimeȱwhileȱanȱ entry/exitȱzoneȱisȱtrippedȱtwiceȱduringȱexitȱtime.ȱȱ YES:ȱExitȱtimeȱwillȱrestartȱforȱoneȱtimeȱonlyȱwhenȱanȱentry/exitȱzoneȱisȱtrippedȱduringȱ exitȱtime.ȱ NO:ȱExitȱtimeȱwillȱnotȱbeȱaffectedȱifȱanȱentry/exitȱzoneȱisȱtrippedȱduringȱexitȱtime.ȱ NOȱ AutoȱStayȱ Thisȱparameterȱisȱusedȱtoȱdefineȱtheȱsystemȇsȱarmingȱmodeȱwhenȱusingȱaȱkeypadȱandȱnoȱ exit/entryȱzoneȱisȱtrippedȱduringȱexitȱmode.ȱȱȱ YES:ȱIfȱnoȱexit/entryȱzoneȱisȱtrippedȱduringȱexitȱtimeȱtheȱsystemȱwillȱbeȱarmedȱinȱSTAYȱ mode.ȱ NO:ȱIfȱnoȱexit/entryȱzoneȱisȱtrippedȱduringȱexitȱtimeȱtheȱsystemȱwillȱbeȱarmedȱinȱAwayȱ mode.ȱȱȱ Page 4-13 AgilityȱEngineerȱManualȱ ȱ System: Controls Parameter Default ExitȱErrorȱ NOȱ ThisȱparameterȱisȱusedȱtoȱdefineȱwhatȱwillȱhappenȱifȱanȱExit/Entryȱzoneȱisȱleftȱopenȱatȱtheȱ endȱofȱtheȱexitȱtime.ȱȱȱ YES:ȱȱ Localȱalarmȱwillȱbeȱactivatedȱatȱtheȱendȱofȱtheȱexitȱtime.ȱȱ ExitȱerrorȱreportȱwillȱbeȱsentȱtoȱtheȱARCȱtogetherȱwithȱanȱalarmȱreportȱifȱtheȱsystemȱ hasȱnotȱbeenȱdisarmedȱduringȱtheȱentryȱtimeȱthatȱimmediatelyȱstartedȱafterȱtheȱexitȱ timeȱexpiration.ȱ NO:ȱȱ Noȱlocalȱalarmȱwillȱbeȱactivatedȱatȱtheȱendȱofȱtheȱexitȱtime.ȱȱ OnlyȱanȱalarmȱreportȱwillȱbeȱsentȱtoȱtheȱARCȱifȱtheȱsystemȱhasȱnotȱbeenȱdisarmedȱ duringȱtheȱentryȱtimeȱthatȱimmediatelyȱstartedȱafterȱtheȱexitȱtimeȱexpirationȱ NOȱ 3ȱMinuteȱBypassȱ YES:ȱBypassesȱallȱzonesȱautomaticallyȱforȱ3ȱminutesȱwhenȱpowerȱisȱrestoredȱtoȱanȱ ȈunpoweredȈȱsystem.ȱ NO:ȱNoȱbypassingȱoccurs.ȱ 1.3 Labels Youȱcanȱrenameȱtheȱlabelsȱthatȱidentifyȱtheȱsystemȱandȱpartitionsȱbyȱchangingȱtheȱdefaultȱ labelsȱ(Partitionȱ1,ȱPartitionȱ2ȱandȱsoȱon)ȱto,ȱforȱexample,ȱTheȱJonesȇs,ȱSalesȱDept,ȱorȱ MastrȱBedrȱasȱappropriate.ȱ Labelsȱthatȱcanȱbeȱrenamed:ȱȱ System: Labels Parameter Systemȱ Default ȱ Range SecurityȱSystemȱ Anyȱ16ȱcharactersȱ Partitionsȱ1ȱthroughȱ3ȱ Anyȱ16ȱcharactersȱ Editsȱtheȱglobalȱ(system)ȱlabelȱȱ Partitionȱ1/2/3ȱ ȱ Editsȱpartitionȱlabelsȱ ȱ Page 4-14 AgilityȱEngineerȱManualȱ ȱ ȱ Toȱrenameȱlabelsȱusingȱtheȱkeypadȱkeysȱtoȱproduceȱcharactersȱseeȱtheȱtableȱbelow:ȱ Key Data Sequence 1ȱ 2ȱ 3ȱ 4ȱ 5ȱ 6ȱ 7ȱ 8ȱ 9ȱ 0ȱ ȱ 1ȱȱȱȱȱ.ȱȱȱȱȱ,ȱȱȱȱȱȇȱȱȱȱȱ?ȱȱȱȱȱ!ȱȱȱȱȱȈȱȱȱȱȱ–ȱȱȱȱȱ(ȱȱȱȱȱ)ȱȱȱȱȱ@ȱȱȱȱȱ/ȱȱȱȱȱ:ȱȱȱȱȱ_ȱȱȱȱȱ+ȱȱȱȱȱ&ȱȱȱȱȱ*ȱȱȱȱȱ#ȱȱ 2ȱȱȱȱȱaȱȱȱȱȱbȱȱȱȱȱcȱȱȱȱȱAȱȱȱȱȱBȱȱȱȱȱCȱ 3ȱȱȱȱȱdȱȱȱȱȱeȱȱȱȱȱfȱȱȱȱȱDȱȱȱȱȱEȱȱȱȱȱFȱ 4ȱȱȱȱȱgȱȱȱȱȱhȱȱȱȱȱiȱȱȱȱȱGȱȱȱȱȱHȱȱȱȱȱIȱ 5ȱȱȱȱȱjȱȱȱȱȱȱkȱȱȱȱȱȱlȱȱȱȱȱJȱȱȱȱȱȱKȱȱȱȱȱLȱ 6ȱȱȱȱmȱȱȱȱȱnȱȱȱȱȱoȱȱȱȱMȱȱȱȱNȱȱȱȱȱOȱ 7ȱȱȱȱȱpȱȱȱȱȱqȱȱȱȱȱrȱȱȱȱȱȱsȱȱȱȱȱPȱȱȱȱȱȱQȱȱȱȱȱRȱȱȱȱȱSȱ 8ȱȱȱȱȱtȱȱȱȱȱȱuȱȱȱȱȱvȱȱȱȱȱTȱȱȱȱUȱȱȱȱȱȱVȱ 9ȱȱȱȱwȱȱȱȱȱxȱȱȱȱȱyȱȱȱȱȱzȱȱȱȱȱWȱȱȱȱȱXȱȱȱȱȱYȱȱȱȱȱZȱ 0ȱ Useȱtheseȱkeysȱtoȱtoggleȱforwardsȱandȱbackwardsȱthroughȱallȱtheȱavailableȱ characters.ȱ ȱ 1.4 Sounds TheȱSoundsȱmenuȱcontainsȱparametersȱthatȱenableȱyouȱtoȱsetȱtheȱsound(s)ȱthatȱwillȱbeȱ producedȱbyȱtheȱsystemȱafterȱtheȱfollowingȱsystemȱevents:ȱȱ System: Sounds Parameter TamperȱSoundȱ Default ȱ Bell/SetȱSilence/Unsetȱ Range 1ȱtoȱ6ȱ Setsȱtheȱsound(s)ȱproducedȱbyȱaȱTamperȱviolationȱaccordingȱtoȱtheȱfollowingȱoptions:ȱ Silentȱ Bellȱ(External/Internalȱsounder)ȱ Buzzerȱ(mainȱunit)ȱ Bellȱ+ȱBuzzerȱ Bell/SȱBuzzer/U:ȱBellȱwhenȱsystemȱset,ȱBuzzerȱwhenȱsystemȱunsetȱ Bell/SȱS/Unset:ȱBellȱwhenȱsystemȱset,ȱSilenceȱwhenȱsystemȱunsetȱ LocalȱSpeakerȱAlarmȱVolumeȱ Levelȱ5ȱ 0Ȭ5ȱ SetsȱtheȱmainȱunitȇsȱinternalȱspeakerȱAlarmȱvolume.ȱTheȱvolumeȱrangesȱbetweenȱ0ȱ(silent)ȱ toȱ5ȱ(Maxȱvolume).ȱAfterȱsetting/changingȱtheȱvolume,ȱsoundȱwillȱbeȱemittedȱbyȱtheȱ internalȱspeakerȱtoȱenableȱevaluationȱofȱtheȱselectedȱvolumeȱlevel.ȱ LocalȱSpeakerȱSquawkȱVolumeȱ Levelȱ5ȱ 0Ȭ5ȱ SetsȱtheȱmainȱunitȇsȱinternalȱspeakerȱSquawkȱvolume.ȱTheȱvolumeȱrangesȱbetweenȱ0ȱ (silent)ȱtoȱ5ȱ(Maxȱvolume).ȱAfterȱsetting/changingȱtheȱvolume,ȱsoundȱwillȱbeȱemittedȱbyȱ theȱinternalȱspeakerȱtoȱenableȱevaluationȱofȱtheȱselectedȱvolumeȱlevel.ȱ Page 4-15 AgilityȱEngineerȱManualȱ ȱ System: Sounds Parameter Default Exit/EntryȱBeepsȱVolumeȱ Levelȱ3ȱ Range 0Ȭ5ȱ DeterminesȱtheȱvolumeȱofȱtheȱbeepsȱsoundedȱfromȱtheȱmainȱunitȱduringȱtheȱExit/Entryȱ times.ȱ SpeakerȱMessagesȱVolumeȱ Levelȱ2ȱ 0Ȭ4ȱ DeterminesȱtheȱvolumeȱofȱtheȱmessagesȱsoundedȱfromȱtheȱmainȱunitȱorȱtheȱListenȬInȱandȱ Talkȱunit.ȱ 1.5 Settings Thisȱoptionȱallowsȱsettingȱtheȱsystemȱinȱcomplianceȱwithȱaȱspecificȱstandardization.ȱ System: Settings Parameter Default Range DefaultȱPanelȱ ȱ ȱ ȱ Restoresȱprogrammingȱoptionsȱtoȱfactoryȱdefaults.ȱ TheȱPanelȱDefaultȱoptionȱwillȱbeȱfollowedȱbyȱquestionsȱregardingȱtheȱdefaultsȱofȱtheȱlabelsȱ andȱerasingȱwirelessȱdevices.ȱUseȱȱ ȱtoȱselectȱyourȱoption.ȱȱ EraseȱWirelessȱDeviceȱ ȱ ȱ Eraseȱwirelessȱdevicesȱwithoutȱchangingȱtheȱsystemȱcurrentȱprogrammedȱparametersȱ.ȱ Languageȱ Setsȱtheȱsystemȱlanguageȱ(Email,ȱSMSȱandȱkeypadȱlanguage)ȱ Standardsȱ ENȱ50131ȱ NOȱ ȱ SetsȱtheȱpanelȱprogrammingȱoptionsȱinȱcomplianceȱwithȱENȱstandards.ȱ(Seeȱ AppendixȱD)ȱ DD243ȱ NOȱ ȱ SetsȱtheȱpanelȱprogrammingȱoptionsȱinȱcomplianceȱwithȱDD243ȱstandards.ȱ CPȬ01ȱ NOȱ ȱ SetsȱtheȱpanelȱprogrammingȱoptionsȱinȱcomplianceȱwithȱCPȬ01ȱstandards.ȱ Page 4-16 AgilityȱEngineerȱManualȱ ȱ ȱ 1.6 Service Information TheȱServiceȱInformationȱmenuȱenablesȱyouȱtoȱinsertȱinformationȱaccessibleȱtoȱtheȱsystemȇsȱ usersȱofȱtheȱalarmȱcompanyȱfromȱwhomȱtheȱserviceȱisȱobtained.ȱȱ System: Service Information Parameter Default Range Nameȱ ȱ Anyȱ16ȱcharactersȱȱ Enablesȱyouȱtoȱinsertȱand/orȱeditȱtheȱnameȱofȱtheȱalarmȱcompanyȱfromȱwhomȱserviceȱ mayȱbeȱobtained.ȱTheȱinformationȱcanȱbeȱviewedȱbyȱtheȱuserȱusingȱtheȱwirelessȱkeypad.ȱȱȱ Phoneȱ ȱ Anyȱ16ȱcharactersȱ Enablesȱyouȱtoȱinsertȱand/orȱeditȱtheȱserviceȱphoneȱnumber.ȱTheȱinformationȱcanȱbeȱ viewedȱbyȱtheȱuserȱusingȱtheȱwirelessȱkeypadȱ 1.7 Firmware Update TheȱAgilityȱenablesȱyouȱtoȱremotelyȱupgradeȱtheȱmainȱunitȱfirmwareȱversionsȱviaȱIPȱorȱ GPRSȱchannels.ȱUnderȱtheȱFirmwareȱUpdateȱmenuȱyouȱneedȱtoȱdefineȱtheȱlocationȱofȱtheȱ upgradeȱfile.ȱȱTheȱrequestȱtoȱstartȱtheȱremoteȱupgradeȱcanȱbeȱdoneȱfromȱtheȱAgilityȱkeypadȱ orȱfromȱtheȱAgilityȱConfigurationȱSoftware.ȱForȱdetailedȱinformationȱreferȱtoȱtheȱRemoteȱ SoftwareȱUpgradeȱinstructionȱguide.ȱ System: Firmware Update Parameter Default Range ServerȱIPȱ 192.114.175.43ȱ ȱ EnterȱtheȱIPȱaddressȱofȱtheȱrouter/gatewayȱwhereȱtheȱupgradeȱfileȱisȱlocated.ȱȱ ServerȱPortȱ 80ȱ ȱ Enterȱtheȱportȱonȱtheȱrouter/gatewayȱwhereȱtheȱupgradeȱfileȱisȱlocated.ȱ FileȱPathȱ ȱ Enterȱtheȱupgradeȱfileȱname.ȱForȱexample:ȱ/Agility/0UK/cpcp.binȱ PleaseȱcontactȱCustomerȱSupportȱservicesȱforȱtheȱfileȱnameȱparameters.ȱ Page 4-17 ȱ AgilityȱEngineerȱManualȱ ȱ 2. Programming: Radio Devices Menu TheȱRadioȱDevicesȱmenuȱprovidesȱaccessȱtoȱsubȬmenusȱthatȱareȱusedȱforȱprogramming,ȱ definingȱandȱeditingȱeachȱofȱtheȱsystemȇsȱwirelessȱdevices.ȱTheȱRadioȱDevicesȱmenuȱisȱ dividedȱintoȱtheȱfollowingȱsubȬmenus:ȱ 1.ȱAllocationȱ 2.ȱModificationȱ 3.ȱIdentificationȱ 2.1 Allocation Eachȱwirelessȱdeviceȱmustȱbeȱidentifiedȱtoȱtheȱsystemȱreceiverȱbeforeȱitsȱparametersȱcanȱbeȱ configured.ȱSeeȱChapterȱ3ȱforȱfurtherȱinformationȱonȱtheȱallocationȱprocedures.ȱ 2.2 Modification Theȱmodificationȱmenuȱisȱusedȱtoȱchangeȱtheȱvaluesȱofȱtheȱparametersȱconfiguredȱbyȱtheȱ systemȱforȱeachȱwirelessȱdevice.ȱTheȱmodificationȱmenuȱisȱdividedȱintoȱtheȱfollowingȱ submenus:ȱ 1.ȱZonesȱ 2.ȱRemoteȱControlsȱ(Keyfobs)ȱ 3.ȱKeypadsȱ 4.ȱSoundersȱ 5.ȱI/OȱModulesȱȱ Note:ȱThisȱlistȱvariesȱaccordingȱtoȱtheȱdevicesȱthatȱhaveȱbeenȱallocatedȱtoȱtheȱsystem.ȱOnlyȱ devicesȱthatȱhaveȱbeenȱallocatedȱcanȱbeȱconfiguredȱorȱmodifiedȱbyȱtheȱengineer.ȱ 2.2.1 Zones TheȱZonesȱmenuȱisȱdividedȱintoȱtheȱfollowingȱsubȬmenus:ȱ Parametersȱ Alarmȱ(Sequential)ȱConfirmationȱȱ SoakȱTestȱ ZoneȱPairingȱȱ Parametersȱ Note:ȱTheȱparametersȱdisplayed,ȱvaryȱaccordingȱtoȱtheȱtypeȱofȱzonesȱconnectedȱtoȱtheȱ system.ȱ Zones: Parameters Parameter Default Labelȱ Zoneȱ01/02/03/ȱ…ȱ Aȱlabelȱidentifiesȱtheȱzoneȱinȱtheȱsystem.ȱUpȱtoȱ16ȱcharacters).ȱȱ Page 4-18 Range Anyȱcharactersȱ AgilityȱEngineerȱManualȱ ȱ Zones: Parameters Parameter Default Range SerialȱNumberȱ TheȱinternalȱIDȱnumberȱofȱtheȱzone.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱIDȱnumber.ȱ PlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱzone.ȱ Partitionȱ ȱ ȱ Theȱpartitionȱ(1ȱtoȱ3)ȱassignmentȱforȱeachȱzone.ȱ Typeȱ ȱ Eachȱzoneȱcanȱbeȱdefinedȱasȱoneȱofȱtheȱfollowingȱtypes:ȱȱ NotȱUsedȱ ȱ ȱ ȱ Disablesȱaȱzone.ȱAllȱunusedȱzonesȱshouldȱbeȱgivenȱthisȱdesignation.ȱ Exit/Entryȱ1ȱȱ ȱ ȱ UsedȱforȱExit/Entryȱdoors.ȱViolatedȱExit/Entryȱzonesȱdoȱnotȱcauseȱanȱintrusionȱ alarmȱduringȱtheȱExit/EntryȱDelay.ȱIfȱtheȱzoneȱisȱnotȱsecuredȱbyȱtheȱendȱtheȱ delayȱexpiresȱitȱwillȱtriggerȱanȱintrusionȱalarm.ȱȱ Toȱstartȱaȱsettingȱprocess,ȱthisȱzoneȱshouldȱbeȱsecured.ȱWhenȱsystemȱisȱset,ȱthisȱ zoneȱstartsȱtheȱentryȱdelayȱtime.ȱȱ Exit/Entryȱ2ȱȱ ȱ ȱ Sameȱasȱabove,ȱexceptȱthatȱtheȱExit/Entryȱ2ȱtimeȱperiodȱapplies.ȱ Exit(Op)/Entryȱ1ȱ ȱ ȱ ȱ UsedȱforȱanȱExit/Entryȱdoor.ȱȱThisȱzoneȱbehavesȱasȱdescribedȱinȱtheȱExit/Entryȱ1ȱ parameter,ȱshownȱabove,ȱexceptȱthat,ȱifȱfaulted,ȱtheȱsettingȱprocessȱisȱnotȱ prevented.ȱToȱavoidȱanȱintrusionȱalarm,ȱitȱmustȱbeȱsecuredȱbeforeȱtheȱexpirationȱ ofȱtheȱExitȱDelayȱperiod.ȱ Exit(Op)/Entryȱ2ȱ ȱ ȱ Sameȱasȱabove,ȱexceptȱthatȱtheȱExitȱ(Op)/Entryȱ2ȱtimeȱperiodȱapplies.ȱ EntryȱFollowerȱ ȱ ȱ Usuallyȱassignedȱtoȱmotionȱdetectorsȱandȱtoȱinteriorȱdoorsȱprotectingȱtheȱareaȱ betweenȱtheȱentryȱdoorȱandȱtheȱsystem.ȱ Thisȱzone(s)ȱcausesȱanȱimmediateȱintrusionȱalarmȱwhenȱviolatedȱunlessȱanȱ Exit/Entryȱzoneȱwasȱviolatedȱfirst.ȱInȱthisȱcase,ȱEntryȱFollowerȱzone(s)ȱwillȱ remainȱomittedȱuntilȱtheȱendȱofȱtheȱEntryȱDelayȱperiod.ȱ Page 4-19 ȱ AgilityȱEngineerȱManualȱ ȱ Zones: Parameters Parameter Intruderȱ(Instant)ȱ Default Range ȱ ȱ UsuallyȱintendedȱforȱnonȬexit/entryȱdoors,ȱwindowȱprotection,ȱshockȱdetection,ȱ andȱmotionȱdetectors.ȱ Causesȱanȱimmediateȱintrusionȱalarmȱifȱviolatedȱafterȱtheȱsystemȱisȱsetȱorȱduringȱ theȱExitȱDelayȱtimeȱperiod.ȱ WhenȱAutoȱSetȱandȱPreȬWarningȱareȱdefined,ȱtheȱinstantȱzoneȱwillȱbeȱsetȱatȱtheȱ endȱofȱtheȱPreȬWarningȱtimeȱperiod.ȱ Interiorȱ+ȱExit/Entryȱ1ȱ ȱ ȱ UsedȱforȱExit/Entryȱdoors,ȱasȱfollows:ȱ IfȱtheȱsystemȱisȱsetȱinȱtheȱFullȱSetȱmode,ȱtheȱzone(s)ȱprovideȱaȱdelayȱ (specifiedȱbyȱExit/Entryȱ1)ȱallowingȱentryȱintoȱandȱexitȱfromȱaȱsetȱ premises.ȱ IfȱtheȱsystemȱisȱsetȱinȱtheȱPartȱSetȱmode,ȱtheȱzoneȱisȱomitted.ȱ Interiorȱ+ȱExit/Entryȱ2ȱ ȱ ȱ SameȱasȱtheȱIȱ+ȱExit/Entryȱ1ȱparameter,ȱdescribedȱabove,ȱbutȱtheȱExit/Entryȱ2ȱ timeȱperiodȱisȱapplicable.ȱ Interiorȱ+ȱExit(Op)/Entryȱ1ȱ ȱ ȱ Usedȱforȱanȱexit/entryȱdoorȱthat,ȱforȱconvenience,ȱmayȱbeȱkeptȱopenȱwhenȱtheȱ systemȱisȱbeingȱset,ȱasȱfollows:ȱ InȱFullȱSetȱmodeȱbehavesȱasȱanȱExitȱ(Op)/Entryȱ1ȱzone.ȱ InȱPartȱSetȱmode,ȱtheȱzoneȱwillȱbeȱomitted.ȱ Interiorȱ+ȱExit(Op)/Entryȱ2ȱ ȱ ȱ SameȱasȱtheȱIȱ+ȱExitȱ(Op)/Entryȱ1ȱparameter,ȱdescribedȱabove,ȱbutȱtheȱExit/Entryȱ 2ȱtimeȱperiodȱisȱapplicable.ȱ Interiorȱ+ȱEntryȱFollowerȱ ȱ ȱ Generallyȱusedȱforȱmotionȱdetectorsȱand/orȱinteriorȱdoorsȱȱ(forȱexample,ȱfoyer),ȱ whichȱwouldȱhaveȱtoȱbeȱviolatedȱafterȱentryȱinȱorderȱtoȱunsetȱtheȱsystem,ȱasȱ follows:ȱ InȱFullȱsetȱmodeȱbehavesȱasȱanȱEntryȱFollowerȱzone.ȱ InȱPartȱSetȱmode,ȱtheȱzoneȱwillȱbeȱomitted.ȱ Interiorȱ+ȱIntruderȱ(Instant)ȱ ȱ ȱ UsuallyȱintendedȱforȱnonȬexit/entryȱdoors,ȱwindowȱprotection,ȱshockȱdetectionȱ andȱmotionȱdetectors.ȱ InȱFullȱSetȱmodeȱbehavesȱasȱanȱIntruderȱ(instant)ȱzone.ȱ InȱPartȱSetȱmode,ȱtheȱzoneȱisȱomitted.ȱ Page 4-20 AgilityȱEngineerȱManualȱ ȱ Zones: Parameters Parameter EntryȱFollowerȱ+ȱPartȱSetȱ Default Range ȱ ȱ Assignedȱtoȱmotionȱdetectorsȱandȱtoȱinteriorȱdoorsȱprotectingȱtheȱareaȱbetweenȱ theȱentryȱdoorȱandȱtheȱkeypad,ȱasȱfollows:ȱȱ InȱFullȱSetȱmodeȱbehavesȱlikeȱanȱEntryȱFollowerȱZone.ȱ InȱPartȱSetȱmodeȱbehavesȱlikeȱanȱExit/Entryȱ1ȱzone.ȱȱ 24ȱHoursȱ ȱ ȱ UsuallyȱassignedȱtoȱprotectȱnonȬmovableȱglass,ȱfixedȱskylights,ȱandȱcabinetsȱ (possibly)ȱforȱshockȱdetectionȱsystems.ȱ Aȱviolationȱofȱsuchȱaȱzoneȱcausesȱanȱinstantȱintrusionȱalarm,ȱregardlessȱofȱtheȱ systemȇsȱstate.ȱ Fireȱ ȱ ȱ Forȱsmokeȱorȱotherȱtypesȱofȱfireȱdetectors.ȱThisȱoptionȱcanȱalsoȱbeȱusedȱforȱ manuallyȱtriggeredȱpanicȱbuttonsȱorȱpullȱstationsȱ(ifȱpermitted),ȱasȱfollows:ȱ Ifȱviolated,ȱitȱcausesȱanȱimmediateȱfireȱalarm,ȱfireȱreportȱtoȱtheȱalarmȱreceivingȱ center.ȱ Panicȱ ȱ ȱ Usedȱforȱexternalȱpanicȱbuttonsȱandȱwirelessȱpanicȱtransmitters.ȱ Ifȱviolated,ȱanȱimmediateȱpanicȱalarmȱisȱsoundedȱ(ifȱtheȱzoneȱsoundȱisȱnotȱ definedȱasȱsilentȱorȱAudibleȱPanicȱsystemȱcontrolȱisȱenabled),ȱregardlessȱofȱtheȱ systemȇsȱstateȱandȱpanicȱreportȱisȱsendȱtoȱtheȱalarmȱreceivingȱcenter.ȱAnȱalarmȱ displayȱwillȱnotȱappearȱonȱtheȱkeypads.ȱ Specialȱ ȱ ȱ Forȱexternalȱauxiliaryȱemergencyȱalertȱbuttonsȱandȱwirelessȱauxiliaryȱemergencyȱ transmitters.ȱ Ifȱviolated,ȱanȱimmediateȱauxiliaryȱemergencyȱalarmȱisȱsounded,ȱregardlessȱofȱ theȱsystemȇsȱstateȱandȱreportȱisȱsentȱtoȱtheȱalarmȱreceivingȱcenter.ȱ Tamperȱȱ ȱ ȱ Forȱtamperȱdetection.ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱzone,ȱbutȱitȱhasȱaȱ specialȱreportingȱcode.ȱ Note:ȱForȱthisȱzoneȱtypeȱtheȱzoneȱsoundȱisȱdeterminedȱaccordingȱtoȱtheȱTamperȱSoundȱdefinedȱ underȱSystemȱÆȱSoundȱÆȱTamperȱ Waterȱȱ(Flood)ȱ ȱ ȱ Forȱfloodȱorȱotherȱtypesȱofȱwaterȱdetectors.ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱ hoursȱzone,ȱbutȱitȱhasȱaȱspecialȱfloodȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱȱ Page 4-21 ȱ AgilityȱEngineerȱManualȱ ȱ Zones: Parameters Parameter Gasȱ Default Range ȱ ȱ ForȱGasȱ(naturalȱgas)ȱleakȱdetector.ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱ zone,ȱbutȱitȱhasȱaȱspecialȱgasȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱ COȱ ȱ ȱ ForȱCOȱ(CarbonȱMonoxide)ȱgasȱdetectors.ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱ hoursȱzone,ȱbutȱitȱhasȱaȱspecialȱCOȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱ HighȱTemperatureȱ ȱ ȱ Forȱdetectorȱtemperatureȱ(hotȱorȱcold).ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱ zone,ȱbutȱitȱhasȱaȱspecialȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱ LowȱTemperatureȱ ȱ ȱ Forȱdetectorȱtemperatureȱ(hotȱorȱcold).ȱThisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱ zone,ȱbutȱitȱhasȱaȱspecialȱreportȱcode.ȱ(SeeȱAppendixȱA:ȱReportȱCodes)ȱ Technicalȱ ȱ ȱ Thisȱzoneȱoperatesȱtheȱsameȱasȱ24ȱhoursȱzone,ȱitsȱȱreportȱcodeȱshouldȱbeȱ manuallyȱsetȱaccordingȱtoȱtheȱrelevantȱdetectorȱconnectedȱtoȱtheȱzone.ȱȱ FinalȱExitȱ ȱ ȱ Zonesȱofȱthisȱtypeȱmustȱbeȱtheȱlastȱdetectorȱtoȱbeȱactivatedȱonȱexitȱorȱtheȱfirstȱ detectorȱtoȱbeȱactivatedȱonȱentry.ȱ Whenȱsettingȱtheȱsystem,ȱtheȱrelatedȱpartitionȱsetsȱ10ȱsecondsȱafterȱthisȱzoneȱisȱ closed,ȱorȱopenedȱandȱthenȱclosed.ȱAfterȱitȱisȱtriggeredȱonce,ȱtheȱzoneȱactsȱasȱanȱ exitȱ(open)/entryȱ1ȱzone.ȱ ExitȱTerminationȱȱ ȱ ȱ ThisȱtypeȱofȱzoneȱisȱusedȱtoȱavoidȱaȱfalseȱalarmȱbyȱactingȱlikeȱanȱExitȱ(OP)/Entryȱ zone.ȱ Whenȱtriggeredȱ(afterȱsettingȱtheȱsystemȱandȱclosingȱtheȱdoorȱorȱopeningȱtheȱ door,ȱsettingȱtheȱsystem,ȱandȱclosingȱtheȱdoor),ȱtheȱsystemȇsȱExitȱDelayȱtimeȱ periodȱwillȱbeȱshortenedȱtoȱ3ȱseconds.ȱ WhenȱyouȱreȬopenȱtheȱdoor,ȱtheȱentryȱtimeȱrestarts.ȱ POȱTriggerȱ ȱ ȱ Forȱaȱdeviceȱorȱzone,ȱwhichȱifȱviolatedȱatȱanyȱtimeȱtriggersȱaȱpreviouslyȱ programmedȱProgrammingȱOutput,ȱcapableȱofȱactivatingȱanȱexternalȱindicator,ȱ relay,ȱappliance,ȱandȱsoȱon.ȱ Page 4-22 AgilityȱEngineerȱManualȱ ȱ Zones: Parameters Parameter Dayȱ Default Range ȱ ȱ Usuallyȱassignedȱtoȱanȱinfrequentlyȱusedȱdoor,ȱsuchȱasȱanȱemergencyȱdoorȱorȱaȱ movableȱskylight.ȱUsedȱtoȱalertȱtheȱsystemȱuserȱifȱaȱviolationȱoccursȱduringȱtheȱ unsetȱperiodȱ(faultȱbyȱday;ȱburglaryȱatȱnight),ȱasȱfollows:ȱ Withȱtheȱsystemȱsetȱ(eitherȱFullȱSetȱorȱPartȱSet),ȱtheȱzoneȱactsȱasȱanȱ instantȱzone.ȱAȱviolationȱofȱthisȱzoneȱafterȱtheȱsystemȱisȱsetȱorȱduringȱ theȱExitȱDelayȱtimeȱperiodȱcausesȱanȱimmediateȱintrusionȱalarm.ȱ Withȱtheȱsystemȱunset,ȱaȱviolationȱofȱthisȱzoneȱattemptsȱtoȱalertȱtheȱ (Fault)ȱLEDȱtoȱflashȱrapidly.ȱThisȱdirectsȱtheȱ userȱbyȱcausingȱtheȱ userȱtoȱviewȱtheȱsystemȇsȱstatus.ȱ Optionally,ȱsuchȱaȱviolationȱcanȱbeȱreportedȱtoȱtheȱARCȱasȱaȱZoneȱFault.ȱ PulsedȱKeyȱSwitchȱ ȱ ȱ Connectȱanȱexternalȱmomentaryȱactionȱkeyȱswitchȱtoȱanyȱzoneȱgivenȱthisȱ designation.ȱThisȱzoneȱwillȱset/unsetȱtheȱpartitionsȱassignedȱtoȱit.ȱ PulsedȱKeyȱSwitchȱDelayedȱ ȱ ȱ UsedȱtoȱapplyȱtheȱExit/EntryȱDelayȱ1ȱparameterȱtoȱtheȱPulsedȱKeyȱSwitchȱzone.ȱ LatchedȱKeyȱSwitchȱ ȱ ȱ ConnectȱanȱexternalȱSPSTȱlatchedȱ(nonȬmomentary)ȱkeyȱswitchȱfollows:ȱ Afterȱsettingȱoneȱorȱmoreȱpartitionsȱusingȱtheȱkeyȱswitchȱandȱthenȱ unsettingȱusingȱtheȱkeypad,ȱtheȱrelatedȱpartitionsȱwillȱbeȱunset.ȱInȱ orderȱtoȱsetȱtheȱpartitionȱusingȱtheȱkeyȱswitchȱagain,ȱturnȱtheȱkeyȱtoȱtheȱ unsetȱpositionȱandȱthenȱtoȱtheȱsetȱposition.ȱȱ Ifȱaȱkeyȱswitchȱlatchȱisȱassignedȱtoȱmoreȱthanȱoneȱpartitionȱandȱoneȱofȱ theȱpartitionsȱisȱsetȱbyȱusingȱtheȱkeypadȱ(theȱkeyȱswitchȱstaysȱinȱtheȱ unsetȱposition),ȱthen:ȱ ȱȬȱWhenȱchangingȱtheȱpositionȱofȱtheȱkeyȱswitchȱtoȱtheȱsetȱposition,ȱallȱ theȱunsetȱpartitions,ȱwhichȱbelongȱtoȱthisȱkeyȱswitch,ȱwillȱbeȱset.ȱ ȱȬȱWhenȱturningȱtheȱkeyȱswitchȱtoȱtheȱunsetȱposition,ȱallȱtheȱpartitionsȱ willȱbeȱunset.ȱ LatchedȱKeyȱSwitchȱDelayȱ ȱ ȱ UsedȱtoȱapplyȱtheȱExit/EntryȱDelayȱ1ȱparameterȱtoȱtheȱlatchedȱkeyȱswitchȱzone.ȱ Soundȱ Bellȱ ȱ Containsȱparametersȱthatȱenableȱyouȱtoȱprogramȱtheȱsoundȱproducedȱwhenȱaȱsystemȱ zoneȱtriggersȱanȱalarmȱforȱtheȱtimeȱdefinedȱunderȱtheȱBellȱTimeȱOutȱparameter.ȱȱ Silentȱȱ ȱ Producesȱnoȱsoundȱ Page 4-23 ȱ ȱ AgilityȱEngineerȱManualȱ ȱ Zones: Parameters Parameter Bellȱȱ Default Range ȱ ȱ Activatesȱtheȱwirelessȱsoundersȱ(internalȱorȱexternal)ȱandȱalarmȱfromȱtheȱmainȱ unitȱassignedȱtoȱtheȱpartitionsȱofȱtheȱzone.ȱ Buzzerȱ(mainȱunit)ȱȱ ȱ ȱ Activatesȱtheȱinternalȱbuzzerȱonȱtheȱmainȱunit.ȱȱ Bellȱ+ȱBuzzerȱȱ ȱ ȱ Activatesȱtheȱwirelessȱsoundersȱandȱsounderȱonȱtheȱmainȱunitȱsimultaneously.ȱ Bell/SetȱBuzzer/Unsetȱȱ ȱ ȱ Inȱaȱcaseȱofȱalarm,ȱtheȱfollowingȱoccurs:ȱ InȱFullȱSetȱmodeȱtheȱwirelessȱsounderȱwillȱoperate.ȱ InȱUnsetȱmode,ȱonlyȱtheȱbuzzerȱonȱtheȱmainȱunitȱwillȱoperate.ȱ Advancedȱprogrammingȱ ȱ ȱ Chimeȱȱ Noneȱ ȱ TheȱChimeȱparameterȱisȱusedȱasȱanȱaudibleȱindicationȱtoȱaȱzoneȱviolationȱwhileȱtheȱ systemȱisȱUnset.ȱDefineȱwhichȱsoundȱoccursȱwhenȱviolated:ȱ Options:ȱ Noneȱ Buzzerȱ(Mainȱunit)ȱ ChimeȱSoundȱ1ȱ ChimeȱSoundȱ2ȱ ChimeȱSoundȱ3ȱ ZoneȱMessageȱ Controlsȱ Supervisionȱ ȱ ȱ ȱ ȱ Chooseȱwhichȱzoneȱwillȱbeȱsupervisedȱbyȱtheȱsystemȱreceiverȱaccordingȱtoȱtheȱ timeȱdefinedȱunderȱtheȱtimerȱRXȱSupervision.ȱ(Seeȱpageȱ4Ȭ4)ȱ Page 4-24 AgilityȱEngineerȱManualȱ ȱ Zones: Parameters Parameter ForcedȱSettingȱY/Nȱ Default Range ȱ ȱ Thisȱoptionȱenablesȱorȱdisablesȱtheȱuseȱofȱforcedȱsettingȱforȱeachȱofȱtheȱsystemȇsȱ zones,ȱasȱfollows:ȱ Ifȱforcedȱsettingȱisȱenabledȱforȱaȱparticularȱzone,ȱitȱallowsȱtheȱsystemȱtoȱbeȱsetȱ evenȱthoughȱthisȱzoneȱisȱfaulty.ȱ Whenȱaȱzone(s)ȱenabledȱforȱforcedȱsettingȱisȱfaulted,ȱtheȱ ȱȱLEDȱblinksȱ duringȱtheȱunsetȱperiod.ȱ Afterȱsetting,ȱallȱzonesȱenabledȱforȱforcedȱsettingȱareȱomittedȱatȱtheȱendȱofȱtheȱ ExitȱDelayȱtimeȱperiod.ȱ Ifȱaȱfaultedȱzoneȱ(oneȱenabledȱforȱforceȱsetting)ȱisȱsecuredȱduringȱtheȱsetȱ period,ȱitȱwillȱnoȱlongerȱbeȱomittedȱandȱwillȱbeȱincludedȱamongȱtheȱsystemȇsȱ setȱzones.ȱȱ NoȱActivityȱȱ ȱ Y/Nȱ DeterminesȱwhetherȱtheȱzoneȱparticipatesȱinȱtheȱNoȱActivityȱfunction.ȱTheȱNoȱ Activityȱfunctionȱisȱforȱreceptionȱofȱsignalsȱusedȱtoȱmonitorȱtheȱactivityȱofȱsick,ȱ elderlyȱorȱdisabledȱpeople.ȱSeeȱTimerȱȈNoȱActivityȈȱonȱpageȱ4Ȭ4.ȱ LEDȱEnableȱY/Nȱ(Onlyȱforȱ2ȱWayȱPIRȱandȱ2ȱWayȱWatchOUT)ȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ Y/Nȱ DefinesȱtheȱLEDȱoperationȱmode.ȱ Yes:ȱDetectorȇsȱLEDȱactivatedȱ No:ȱDetectorȇsȱLEDȱdeactivatedȱ AbortȱAlarmȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ Y/Nȱ ThisȱparameterȱdefinesȱwhetherȱaȱzoneȱalarmȱreportȱtoȱtheȱAlarmȱReceivingȱ Centerȱwillȱbeȱimmediateȱorȱdelayed:ȱȱ YES:ȱAȱreportȱtoȱtheȱARCȱwillȱbeȱdelayedȱaccordingȱtoȱtheȱAbortȱTimeȱDelayȱ parameterȱ(CommunicationÆȱARCȱÆȱARCȱTimesÆAbortȱAlarm).ȱȱȱ Note:ȱIfȱaȱvalidȱUserȱCodeȱisȱenteredȱtoȱresetȱtheȱalarmȱwithinȱtheȱcancelȱdelayȱtimeȱ (CommunicationÆARCÆȱARCȱTimesÆCancelȱReport),ȱaȱcancelȱreportȱalarmȱcodeȱwillȱbeȱ sentȱtoȱtheȱARC.ȱ NO:ȱAȱreportȱtoȱtheȱMSȱwillȱbeȱsentȱimmediately.ȱȱ DetectionȱModeȱ(Onlyȱforȱ2ȱWayȱDetectors)ȱ Normalȱ Fastȱ(WalkȱTest):ȱWhenȱtheȱdetectorȱisȱinȱdisarmȱitȱwillȱtransmitȱafterȱeachȱdetectionȱȱ Normalȱ(Default):ȱWhenȱtheȱdetectorȱisȱinȱdisarm,ȱthereȱwillȱbeȱ2.5ȱminutesȱdeadȱtimeȱ betweenȱdetectionȱtransmissions Note:ȱForȱbothȱoptions,ȱwhenȱtheȱdetectorȱisȱarmedȱitȱwillȱtransmitȱafterȱeachȱdetection.ȱ Page 4-25 ȱ AgilityȱEngineerȱManualȱ ȱ Zones: Parameters Parameter Default Range Sensitivityȱ(Onlyȱforȱ2ȱWayȱPIRȱandȱ2ȱWayȱWatchOUT)ȱ ȱ ȱ DefinesȱtheȱPIRȱSensitivityȱofȱtheȱdetector.ȱ Lowȱ Mediumȱ(2ȱWayȱWatchOUT)ȱ Highȱ Maximumȱ(2ȱWayȱWatchOUT)ȱ AlarmȱConfirmationȱ TheȱAlarmȱConfirmationȱmenuȱenablesȱtoȱdefineȱprotectionȱagainstȱfalseȱalarmsȱandȱwillȱ beȱusedȱforȱalarmȱverification. Zones: Alarm Confirmation Parameter Default Range ConfirmȱPartitionȱȱ ȱ ȱ Definesȱwhichȱpartitionsȱwillȱbeȱdefinedȱforȱalarmȱsequentialȱconfirmation.ȱ Eachȱconfirmedȱpartitionȱhasȱaȱseparateȱtimer,ȱwhichȱisȱequivalentȱtoȱtheȱconfirmationȱ timeȱdefinedȱinȱ“ConfirmationȱTimeȱWindow”.ȱ Aȱconfirmedȱintruderȱalarmȱwillȱbeȱreportedȱifȱtwoȱseparateȱalarmȱconditionsȱareȱ detectedȱinȱtheȱsameȱconfirmedȱpartition,ȱduringȱtheȱconfirmationȱtime.ȱ ConfirmȱZonesȱȱ ȱ ȱ Defineȱwhichȱzonesȱwillȱbeȱdefinedȱforȱalarmȱsequentialȱconfirmation.ȱȱ Whenȱtheȱfirstȱzoneȱgoesȱintoȱalarmȱtheȱsystemȱtransmitsȱtheȱfirstȱzoneȱalarm.ȱWhenȱtheȱ secondȱzoneȱgoesȱintoȱalarm,ȱduringȱtheȱconfirmationȱtime,ȱtheȱpanelȱtransmitsȱtheȱzoneȱ alarmȱandȱtheȱPoliceȱcode.ȱ Notes:ȱȱȱ 1.ȱAȱconfirmedȱzoneȱwillȱbeȱpartȱofȱtheȱsequentialȱconfirmationȱonlyȱifȱtheȱpartitionȱinȱwhichȱtheȱalarmȱ occursȱisȱdefinedȱasȱconfirmedȱpartitionȱasȱwell.ȱ 2.ȱAnyȱCodeȱcanȱresetȱaȱconfirmedȱalarm.ȱȱ 3.ȱIfȱtheȱfirstȱzoneȱisȱviolatedȱandȱnotȱrestoredȱuntilȱtheȱendȱofȱtheȱconfirmationȱtimeȱ(noȱsecondȱzoneȱ alarm),ȱthanȱthisȱzoneȱwillȱbeȱexcludedȱfromȱtheȱconfirmationȱprocessȱuntilȱtheȱnextȱsetting.ȱȱȱ SoakȱTestȱ TheȱSoakȱTestȱfeatureȱisȱdesignedȱtoȱallowȱfalseȱalarmingȱforȱpredefinedȱdetectorsȱtoȱbeȱ omittedȱfromȱtheȱsystem,ȱwhileȱanyȱalarmsȱgeneratedȱareȱdisplayedȱtoȱtheȱuserȱforȱ reportingȱtoȱtheȱARC.ȱThisȱisȱespeciallyȱusefulȱifȱPoliceȱresponseȱwithdrawalȱisȱbeingȱ threatenedȱandȱaȱparticularȱzoneȱisȱcausingȱunidentifiedȱproblems.ȱ Page 4-26 AgilityȱEngineerȱManualȱ ȱ EachȱzoneȱcanȱbeȱplacedȱonȱSoakȱTest.ȱAnyȱzoneȱplacedȱinȱtheȱSoakȱTestȱlistȱisȱomittedȱ fromȱtheȱsystemȱforȱ14ȱdaysȱandȱisȱautomaticallyȱreinstatedȱafterȱthatȱtimeȱifȱNOȱalarmsȱ haveȱbeenȱgeneratedȱbyȱit.ȱ IfȱaȱzoneȱinȱtheȱSoakȱTestȱlistȱhasȱanȱalarmȱduringȱtheȱ14Ȭdayȱperiod,ȱtheȱkeypadȱindicatesȱ toȱtheȱuserȱthatȱtheȱtestȱhasȱfailed.ȱAfterȱtheȱuserȱlooksȱatȱtheȱViewȱFaultȱoption,ȱtheȱfaultȱ messageȱwillȱbeȱerased.ȱThisȱwillȱbeȱindicatedȱinȱtheȱeventȱlog,ȱbutȱnoȱalarmȱwillȱbeȱ generated.ȱTheȱalarmedȱzoneȇsȱ14ȬdayȱSoakȱTestȱperiodȱisȱthenȱresetȱandȱrestarted.ȱ ZoneȱPairingȱȱ TheȱZoneȱPairingȱmenuȱisȱusedȱforȱadditionalȱprotectionȱfromȱfalseȱalarmsȱandȱcontainsȱ parametersȱthatȱenableȱyouȱtoȱlinkȱtogetherȱtwoȱrelatedȱzones.ȱBothȱmustȱbeȱviolatedȱ withinȱaȱdesignatedȱtimeȱperiodȱ(betweenȱ1ȱandȱ9ȱminutes)ȱbeforeȱanȱalarmȱoccurs.ȱ ThisȱtypeȱofȱlinkingȱisȱusedȱwithȱmotionȱdetectorsȱinȱhostileȱorȱfalseȬalarmȱproneȱ environments. Default:ȱNoȱcrossȱzoning Zones: Zone Pairing Parameter 1stȱZoneȱ ȱ ȱ ȱ ȱ ȱ ȱ Theȱ1stȱzoneȱofȱaȱpairȱofȱzoneȱdefinedȱforȱzoneȱcrossings.ȱ 2ndȱZoneȱ Theȱ2ndȱzoneȱofȱaȱpairȱofȱzoneȱdefinedȱforȱzoneȱcrossings.ȱ Timeȱ Theȱamountȱofȱtimeȱallowedȱbetweenȱtheȱtriggeringȱeventsȱforȱbothȱzonesȱtoȱbeȱ consideredȱaȱvalidȱviolationȱ CorrelationȱTypeȱ ȱ ȱ DetermineȱhowȱtheȱAgilityȱwillȱprocessȱviolationsȱofȱtheȱpairedȱzones.ȱȱ Notȱcorrelateȱ(None):ȱTemporarilyȱdisablesȱanyȱassociatedȱzoneȱpairingsȱ Orderedȱcorrelate:ȱEffectsȱanȱalarmȱsoȱtheȱfirstȱlistedȱzoneȱisȱtrippedȱbeforeȱtheȱ secondȱ Notȱorderedȱcorrelate:ȱAffectsȱanȱalarmȱinȱwhichȱeitherȱzoneȱinȱtheȱpairȱmayȱbeȱ trippedȱfirst.ȱIfȱthisȱcase,ȱtheȱspecifiedȱzoneȱorderȱ(1st,ȱ2nd)ȱhasȱnoȱbearingȱonȱ theȱalarmȱactivation.ȱ Note:ȱZonesȱcrossedȱwithinȱthemselvesȱareȱvalidȱpairs.ȱTheyȱneedȱtoȱregisterȱaȱviolationȱtwiceȱtoȱtriggerȱtheȱ ȱ alarm.ȱThisȱprocessȱisȱknownȱasȱDoubleȱKnock.ȱ Page 4-27 ȱ AgilityȱEngineerȱManualȱ ȱ 2.2.2 Remote Controls TheȱRemoteȱControlsȱmenuȱdefinesȱtheȱoperationȱofȱtheȱremoteȱcontrols.ȱUpȱtoȱ8ȱremoteȱ controlsȱcanȱbeȱassignedȱtoȱtheȱsystem.ȱTheȱsystemȱsupportsȱ2ȱtypesȱofȱremoteȱcontrols:ȱ OneȱWayȱRemoteȱControlsȱ(4ȱbutton)ȱȱ TwoȱWayȱ(bidirectional)ȱRemoteȱControlsȱ(8ȱbutton)ȱ Parametersȱ Theȱprogrammingȱoptionsȱunderȱtheȱparametersȱmenuȱvaryȱaccordingȱtoȱtheȱtypeȱofȱtheȱ remoteȱcontrol.ȱȱ OneȱWayȱRemoteȱControlȱParametersȱ Eachȱoneȱwayȱremoteȱcontrolȱconsistsȱofȱ4ȱbuttons,ȱandȱeachȱbuttonȱcanȱbeȱprogrammedȱtoȱ aȱdifferentȱmodeȱofȱoperation.ȱ Remote Controls Parameters: One Way Remote Controls Parameter Labelȱ ȱ ȱ ȱ ȱ Aȱlabelȱidentifyingȱtheȱuserȱofȱtheȱremoteȱcontrol.ȱȱ SerialȱNumberȱ TheȱinternalȱIDȱnumberȱofȱtheȱremoteȱcontrol.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱ serialȱnumber.ȱPlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱremoteȱcontrol.ȱ Partitionȱ ȱ ȱ ȱ ȱ Assignȱtheȱrelevantȱpartitionsȱforȱtheȱselectedȱremoteȱcontrol.ȱ Buttonȱ1ȱ(±)ȱ Setȱtheȱoperationȱofȱbuttonȱ1ȱofȱtheȱremoteȱcontrolȱfromȱtheȱfollowingȱoptions:ȱ None:ȱButtonȱdisabled.ȱ Set:ȱTheȱbuttonȱisȱusedȱforȱFullȱsettingȱofȱtheȱremoteȱcontrolȇsȱpartitions.ȱȱ PartȱSet:ȱTheȱbuttonȱisȱusedȱforȱPartȱSettingȱofȱtheȱremoteȱcontrolȇsȱpartitions.ȱ Buttonȱ2ȱ(²)ȱ ȱ ȱ Setȱtheȱoperationȱofȱbuttonȱ2ȱofȱtheȱremoteȱcontrolȱfromȱtheȱfollowingȱoptions:ȱ None:ȱButtonȱdisabled.ȱ Unset:ȱTheȱbuttonȱisȱusedȱforȱunsettingȱitsȱassignedȱpartitions.ȱ Buttonȱ3ȱ ȱ ȱ Setȱtheȱoperationȱofȱbuttonȱ3ȱ(Smallȱblankȱbutton)ȱofȱtheȱremoteȱcontrolȱfromȱtheȱ followingȱoptions:ȱ None:ȱButtonȱdisabled.ȱ Panic:ȱTheȱbuttonȱisȱusedȱtoȱsendȱaȱpanicȱalarm.ȱ POȱControlȱ(1Ȭ20):ȱTheȱbuttonȱisȱusedȱtoȱoperateȱaȱsingleȱProgrammingȱOutput.ȱ Page 4-28 AgilityȱEngineerȱManualȱ ȱ ȱ Remote Controls Parameters: One Way Remote Controls Parameter Buttonȱ4ȱ ȱ ȱ Setȱtheȱoperationȱofȱbuttonȱ4ȱ(Largeȱblankȱbutton)ȱofȱtheȱremoteȱcontrolȱfromȱtheȱ followingȱoptions:ȱ None:ȱButtonȱdisabled.ȱ Set:ȱTheȱbuttonȱisȱusedȱforȱFullȱsettingȱofȱtheȱremoteȱcontrolȇsȱpartitions.ȱȱ PartȱSet:ȱTheȱbuttonȱisȱusedȱforȱPartȱSettingȱofȱtheȱremoteȱcontrolȇsȱpartitions.ȱȱ POȱControlȱ(1Ȭ20):ȱTheȱbuttonȱisȱusedȱtoȱoperateȱaȱProgrammingȱOutput.ȱ ȱ TwoȱWayȱBiȬdirectionalȱRemoteȱControlsȱ Theȱbiȱdirectionalȱremoteȱcontrolȱisȱanȱ8ȱbuttonȱrollingȱcodeȱwirelessȱtransmitterȱdesignedȱ forȱremoteȱsystemȱoperation.ȱBeingȱbiȬdirectionalȱenablesȱeachȱcommandȱthatȱisȱsentȱtoȱtheȱ panelȱtoȱreceiveȱaȱreplyȱstatusȱindicationȱbackȱfromȱtheȱpanelȱusingȱitsȱ3ȱcolorȱLEDsȱandȱ internalȱbuzzerȱsounder.ȱȱForȱhigherȱsecurity,ȱcommandsȱcanȱbeȱdefinedȱtoȱbeȱactivatedȱ withȱaȱ4ȱdigitȱPINȱcode.ȱ Remote Controls Parameters: 2 Way Remote Control Parameter Labelȱ ȱ ȱ Aȱlabelȱidentifyingȱtheȱuserȱofȱtheȱremoteȱcontrol.ȱȱ SerialȱCodeȱ TheȱinternalȱIDȱnumberȱofȱtheȱremoteȱcontrol.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱ serialȱnumber.ȱPlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱremoteȱcontrol.ȱ Partitionȱ ȱ ȱ ȱ ȱ Assignȱtheȱrelevantȱpartitionsȱforȱtheȱselectedȱremoteȱcontrol.ȱ PINȱCodeȱ 4ȱdigitȱPINȱcodeȱusedȱforȱhigherȱsecurityȱwhenȱsendingȱcommandsȱfromȱtheȱremoteȱ control.ȱTheȱcodeȱcanȱbeȱcomprisedȱfromȱdigitsȱ1,2,3,4.ȱȱ Note:ȱTheȱuseȱofȱtheȱPINȱcodeȱdependsȱonȱtheȱcontrolȱQuickȱPOȱorȱsystemȱcontrolȱQuickȱSetȱ PanicȱEnableȱ ȱ ȱ Defineȱwhetherȱsendingȱpanicȱalarmȱfromȱtheȱremoteȱcontrolȱisȱpermitted.ȱIfȱpermitted,ȱ pressingȱonȱkeysȱ alarm.ȱ ȱandȱ ȱsimultaneouslyȱforȱ2ȱsecondsȱonȱtheȱwillȱsendȱaȱpanicȱ POȱButtonȱ1/2/3ȱ ȱ ȱ Eachȱremoteȱcontrolȱcanȱactivateȱupȱtoȱ3ȱoutputs.ȱAssignȱtoȱeachȱofȱtheȱkeysȱ1Ȭ3ȱtheȱ relevantȱoutput.ȱ Page 4-29 AgilityȱEngineerȱManualȱ ȱ Controlsȱ TheȱControlsȱmenuȱoptionsȱareȱusedȱforȱbothȱtypesȱofȱremoteȱcontrols.ȱ Remote Controls: Controls Control InstantȱF.ȱSetȱ NOȱ ȱ YES:ȱFullȱsettingȱfromȱanyȱremoteȱcontrolȱwillȱbeȱinstant.ȱ NO:ȱFullȱsettingȱfromȱanyȱremoteȱcontrolȱwillȱbeȱdelayed,ȱfollowingȱexitȱdelayȱ1.ȱ InstantȱPartȱSetȱ NOȱ ȱ YES:ȱPartȱSettingȱfromȱanyȱremoteȱcontrolȱwillȱbeȱinstant.ȱ NO:ȱPartȱSettingȱfromȱanyȱremoteȱcontrolȱwillȱbeȱdelayed,ȱfollowingȱexitȱdelayȱ1.ȱ Unsetȱ+ȱCodeȱ(Forȱ2ȱWayȱRemoteȱControls)ȱ NOȱ ȱ DefinesȱifȱaȱPINȱcodeȱisȱrequiredȱtoȱperformȱtheȱunsetȱoperationȱwhileȱusingȱanyȱofȱtheȱ bidirectionalȱremoteȱcontrols.ȱȱ ParentȱControlȱ TheȱParentȱControlȱoptionȱisȱusedȱtoȱmonitorȱtheȱactivityȱofȱchildren.ȱThisȱoptionȱallowsȱ youȱtoȱmonitorȱwhenȱtheȱchildrenȱarriveȱhomeȱandȱunsetȱtheȱsystemȱorȱwhenȱtheyȱsetȱtheȱ systemȱinȱFullȱSet,ȱusingȱaȱremoteȱcontrolȱorȱtheȱkeypad.ȱWithȱeachȱactivation/deactivationȱ ofȱtheȱsystemȱaȱmessageȱisȱsentȱtoȱaȱspecifiedȱFollowȱMeȱnumber.ȱ Afterȱselectingȱthisȱoption,ȱusingȱtheȱ key,ȱdefineȱwhichȱofȱtheȱremoteȱcontrolsȱareȱ authorizedȱwithȱthisȱfeatureȱandȱwhichȱareȱnot.ȱȱ 2.2.3 Keypads Theȱsystemȱcanȱsupportȱupȱtoȱ3ȱwirelessȱkeypads.ȱȱ Forȱdetailedȱinformationȱregardingȱtheȱoperationȱofȱtheȱkeypadsȱreferȱtoȱtheȱinstructionsȱ suppliedȱwithȱtheȱproduct.ȱ Parametersȱ Keypads: Parameters Parameter Default Range Labelȱ ȱ ȱ ȱ ȱ Aȱlabelȱidentifyingȱtheȱkeypadȱ SerialȱNumberȱ TheȱinternalȱIDȱnumberȱofȱtheȱkeypad.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱserialȱ number.ȱPlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱremoteȱkeypad.ȱ Page 4-30 AgilityȱEngineerȱManualȱ ȱ ȱ Keypads: Parameters Parameter Default EmergencyȱKeysȱ YESȱ Range YES/NOȱ Definesȱwhetherȱtheȱfollowingȱkeysȱwillȱoperateȱasȱemergencyȱkeys:ȱ Keysȱ ȱandȱ ȱwhenȱpressedȱsimultaneouslyȱwillȱsendȱaȱfireȱalarm.ȱ Keysȱ ȱandȱ ȱwhenȱpressedȱsimultaneouslyȱwillȱsendȱanȱemergencyȱalarm.ȱ ȱ FunctionȱKeyȱ Definesȱtheȱoperationȱofȱtheȱ Panicȱ ȱ ȱ ȱkeysȱforȱeachȱkeypad.ȱ Disable:ȱKeysȱdisabled.ȱ Panic:ȱSendȱaȱpanicȱalarmȱtoȱtheȱalarmȱreceivingȱcenter.ȱ ARCȱListenȬInȱ&ȱTalk:ȱTheȱsystemȱdialsȱtheȱARCȱtoȱestablishȱ2Ȭwayȱcommunication.ȱ POȱControlȱȱ ȱ Assignȱoutputsȱthatȱwillȱbeȱactivatedȱbyȱaȱlongȱpressȱonȱkeysȱ bidirectionalȱkeypad.ȱ ȱ onȱtheȱ Notes:ȱȱ OutputsȱcanȱbeȱassignedȱonlyȱifȱI/Oȱisȱassignedȱtoȱtheȱsystem.ȱ Eachȱkeypadȱcanȱactivateȱdifferentȱoutputs.ȱȱ OnlyȱoutputsȱdefinedȱasȱFollowȱCodeȱcanȱbeȱactivatedȱbyȱtheȱkeypadȱkeys Controlsȱ TheȱControlsȱmenuȱdefinesȱprogrammingȱoptionsȱthatȱareȱusedȱforȱallȱkeypads.ȱ Keypads: Controls Parameter Default Range RFȱWakeȬupȱ NOȱ ȱ Determinesȱwhetherȱtheȱsystemȱcanȱwakeȱtheȱkeypadȱupȱduringȱexit/entryȱtimesȱorȱ whenȱfailingȱtoȱsetȱtheȱsystem.ȱ YES:ȱTheȱsystemȱwakesȱtheȱkeypad.ȱ NO:ȱTheȱsystemȱcannotȱwakeȱupȱaȱkeypad.ȱUseȱthisȱoptionȱtoȱsaveȱbatteryȱlife.ȱ(Default)ȱ Page 4-31 AgilityȱEngineerȱManualȱ ȱ 2.2.4 Sounders TheȱSoundersȱmenuȱenablesȱtoȱdefineȱallȱparametersȱofȱexternalȱandȱinternalȱwirelessȱ soundersȱthatȱcanȱbeȱconnectedȱtoȱtheȱsystem.ȱUpȱtoȱ3ȱsoundersȱcanȱbeȱaddedȱtoȱtheȱ system.ȱȱ Forȱdetailedȱinformationȱregardingȱtheȱoperationȱofȱtheȱsoundersȱreferȱtoȱtheȱinstructionsȱ suppliedȱwithȱtheȱproduct.ȱȱȱȱȱ Wireless Device: Sounders Parameter Default Labelȱ Range ȱ ȱ ȱ ȱ Aȱlabelȱidentifyingȱtheȱsounder.ȱ SerialȱNumberȱ TheȱinternalȱIDȱnumberȱofȱtheȱsounders.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱserialȱ number.ȱPlacingȱIDȱ00000000000ȱwillȱdeleteȱtheȱsounder.ȱ Partitionȱ ȱ ȱ Assignȱtheȱpartitionsȱthatȱwillȱeffectȱtheȱsounderȱoperation.ȱ Supervisionȱ YESȱ ȱ Chooseȱifȱtheȱsounderȱwillȱbeȱsupervisedȱorȱnot.ȱ Volumeȱ 9ȱ 0Ȭ9ȱ Defineȱtheȱvolumeȱofȱtheȱsounderȱforȱtheȱfollowingȱscenariosȱinȱtheȱsystem.ȱ AlarmȱVolumeȱ 9ȱ 0Ȭ9ȱ Theȱsoundȱvolumeȱproducedȱduringȱalarmȱ(0ȱindicatesȱsilence).ȱ SquawkȱVolumeȱ 9ȱ 0Ȭ9ȱ Theȱsoundȱvolumeȱproducedȱduringȱsquawkȱsoundsȱ(0ȱindicatesȱsilence).ȱ Exit/EntryȱVolumeȱ 9ȱ 0Ȭ9ȱ Theȱsoundȱvolumeȱproducedȱduringȱexit/entryȱtime.ȱ(0ȱindicatesȱsilence).ȱ Strobeȱ(Externalȱsounderȱonly)ȱ 9ȱ 0Ȭ9ȱ ȱ ȱ Definesȱtheȱparametersȱforȱtheȱstrobeȱofȱtheȱexternalȱsounder.ȱ StrobeȱControlȱȱ DefinesȱtheȱStrobeȱoperationȱmode:ȱ Alwaysȱoff:ȱTheȱstrobeȱisȱdeactivatedȱ FollowȱBell:ȱTheȱstrobeȱisȱactivatedȱwhenȱtheȱsounderȱbellȱisȱtriggeredȱ FollowȱAlarm:ȱTheȱstrobeȱisȱactivatedȱwhenȱanȱalarmȱeventȱoccursȱinȱtheȱȱ ȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱsystem.ȱ Page 4-32 AgilityȱEngineerȱManualȱ ȱ ȱ Wireless Device: Sounders Parameter StrobeȱBlinkȱ Default Range 40ȱ ȱ Definesȱtheȱnumberȱofȱtimesȱthatȱtheȱstrobeȱwillȱblinkȱinȱaȱminute:ȱ 20ȱtimesȱperȱminuteȱ 30ȱtimesȱperȱminuteȱ 40ȱtimesȱperȱminuteȱȱ 50ȱtimesȱperȱminuteȱ 60ȱtimesȱperȱminuteȱ StrobeȱSetȱBlinkȱ 05ȱ 00Ȭ20ȱ Definesȱtheȱtimeȱthatȱtheȱstrobeȱwillȱblinkȱwhenȱtheȱsystemȱisȱset.ȱ 2.2.5 I/O Wireless Expander TheȱWirelessȱInput/OutputȱExpanderȱisȱaȱselfȱpoweredȱdeviceȱenablingȱsystemȱcontrolȱofȱ additionalȱ4ȱwiredȱzonesȱandȱhasȱhomeȱautomationȱcapabilities.ȱWithȱtheȱI/OȱExpanderȱtheȱ systemȱcanȱcontrolȱ4ȱoutputsȱandȱ16ȱhomeȱautomationȱunitsȱemployingȱtheȱX10ȱprotocol.ȱ WiredȱZonesȱ Theȱ4ȱinputsȱonȱtheȱI/OȱExpanderȱareȱregardedȱasȱzonesȱ33Ȭ36ȱinȱtheȱsystem.ȱȱ I/O Expander: Wired Zones Parameter Default Labelȱ Range ȱ ȱ 1ȱ ȱ Aȱlabelȱidentifiesȱtheȱzoneȱinȱtheȱsystem.ȱ(upȱtoȱ16ȱcharacters).ȱ Partitionȱ Theȱpartitionsȱassignmentȱforȱeachȱzone.ȱ Typeȱ Intruderȱ ȱ Containsȱparametersȱthatȱenableȱyouȱtoȱprogramȱtheȱzoneȱtypeȱforȱanyȱzone.ȱReferȱtoȱtheȱ listȱofȱoptionsȱforȱtheȱZoneȱTypeȱonȱpageȱ4Ȭ19.ȱ Soundȱ Bellȱ ȱ Containsȱparametersȱthatȱenableȱyouȱtoȱprogramȱtheȱsoundȱproducedȱwhenȱaȱsystemȱ zoneȱtriggersȱanȱalarmȱforȱtheȱtimeȱdefinedȱunderȱtheȱBellȱTimeȱOutȱparameter.ȱReferȱtoȱ theȱlistȱofȱoptionsȱforȱtheȱZoneȱSoundȱonȱpageȱ4Ȭ23.ȱ Advancedȱprogrammingȱ ȱ Chimeȱ ȱ Noneȱ ȱ TheȱChimeȱparameterȱisȱusedȱasȱanȱaudibleȱindicationȱtoȱaȱzoneȱviolationȱwhileȱtheȱ systemȱisȱUnset.ȱWhenȱviolated,ȱtheȱmainȱunitȱcanȱsoundȱoneȱofȱtheȱ5ȱavailableȱchimeȱ options.ȱȱ Page 4-33 AgilityȱEngineerȱManualȱ ȱ I/O Expander: Wired Zones Parameter Default Range Controlsȱ ForcedȱSetȱ NOȱ ȱ Defineȱwhetherȱtheȱzoneȱcanȱbeȱforcedȱsetȱorȱnot.ȱForȱmoreȱinformationȱ regardingȱtheȱforceȱsettingȱfeature,ȱreferȱtoȱpageȱ4Ȭ25.ȱ NoȱActivityȱ NOȱ ȱ DeterminesȱwhetherȱtheȱzoneȱparticipatesȱinȱtheȱNoȱActivityȱfunction.ȱTheȱNoȱ Activityȱfunctionȱisȱforȱreceptionȱofȱsignalsȱusedȱtoȱmonitorȱtheȱactivityȱofȱsick,ȱ elderlyȱorȱdisabledȱpeople.ȱ.Forȱmoreȱinformationȱregardingȱtheȱforceȱsettingȱ feature,ȱreferȱtoȱpageȱ4Ȭ25.ȱ AbortȱAlarmȱ YESȱ ȱ ThisȱparameterȱdefinesȱwhetherȱaȱzoneȱalarmȱreportȱtoȱtheȱARCȱwillȱbeȱ immediateȱorȱdelayed.ȱForȱmoreȱinformationȱregardingȱtheȱforceȱarmingȱfeatureȱ referȱtoȱpageȱ4Ȭ25.ȱ Terminationȱ ȱ ȱ TheȱTerminationȱmenuȱenablesȱyouȱtoȱprogramȱtheȱconnectionȱtypeȱusedȱforȱtheȱwiredȱ zonesȱ33Ȭ36.ȱTheȱactualȱ(physical)ȱterminationȱforȱeachȱzoneȱmustȱcomplyȱwithȱthatȱ selectedȱinȱtheȱzoneȱterminationȱmenu.ȱ N/C:ȱ(NormallyȱClosed)ȱUsesȱnormallyȬclosedȱcontactsȱandȱnoȱterminatingȱEndȬofȬ LineȱResistor.ȱ N/O:ȱ(NormallyȱOpen)ȱUsesȱnormallyȬopenȱcontactsȱandȱnoȱterminatingȱEndȬofȬLineȱ Resistorȱȱ EOL:ȱ(EndȱofȱLine)ȱUsesȱnormallyȬclosedȱ(NC)ȱand/orȱnormallyȬopenȱ(NO)ȱcontactsȱ inȱaȱzoneȱterminatedȱbyȱaȱsuppliedȱ2200:ȱEndȬofȬLineȱResistorȱȱ NORMALLY CLOSED ZONE CONFIGURATION zone com NORMALLY OPEN ZONE CONFIGURATION zone com END OF LINE ZONE (N.C CONTACT) zone com END OF LINE ZONE (N.O CONTACT) zone 2.2 K 2.2 K ALARM ALARM DETECTOR DETECTOR ALARM ALARM DETECTOR Page 4-34 com DETECTOR ȱ D AgilityȱEngineerȱManualȱ ȱ ȱ I/O Expander: Wired Zones Parameter Default Range Loopȱresponseȱ ȱ ȱ TheȱLoopȱResponseȱmenuȱenablesȱyouȱtoȱsetȱtheȱdifferentȱtimesȱforȱwhichȱaȱwiredȱzoneȱ violationȱmustȱexistȱbeforeȱtheȱzoneȱwillȱtriggerȱanȱalarmȱcondition.ȱ Theȱfollowingȱoptionȱareȱavailable:ȱ Normalȱ400ȱmsȱȱ 0.5ȱhoursȱȱ 2ȱhoursȱȱ 3.5ȱhoursȱȱ Slowȱ1ȱsecondȱ 1ȱhourȱ 2.5ȱhoursȱ 4ȱhoursȱ Fastȱ10ȱmsȱ 1.5ȱhoursȱ 3ȱhoursȱ ȱ ȱ DetectionȱModeȱ ȱ ȱ Normalȱ(Default):ȱ2.5ȱminutesȱdeadȱtimeȱbetweenȱalarmȱdetectionsȱtransmissions.ȱ Fastȱ(WalkȱTest):ȱAlarmȱdetectionȱisȱimmediatelyȱtransmitted.ȱ OutputȱParametersȱ TheȱI/Oȱexpanderȱhasȱ4ȱphysicalȱoutputsȱonȱboard.ȱ(2ȱrelayȱ3Ampȱandȱ2ȱTransistorȱOutputsȱ (500ȱmA) I/O Expander: Output Parameters Parameter Labelȱ ȱ ȱ ȱ ȱ Aȱlabelȱidentifiesȱtheȱoutputȱinȱtheȱsystem.ȱȱ Typeȱ Thereȱareȱ4ȱtypesȱofȱoutputsȱinȱtheȱsystemȱasȱfollowsȱ Notȱusedȱ FollowȱSystem:ȱTheȱprogrammingȱoutputȱwillȱfollowȱaȱSystemȱEventȱ FollowȱPartition:ȱTheȱprogrammingȱoutputȱwillȱfollowȱaȱPartitionȱEvent.ȱȱ FollowȱZone:ȱTheȱprogrammingȱoutputȱwillȱfollowȱaȱZoneȱEvent.ȱEachȱProgrammingȱ Outputȱcanȱbeȱactivatedȱbyȱaȱgroupȱofȱupȱtoȱfiveȱzones.ȱ FollowȱCode:ȱTheȱprogrammingȱoutputȱwillȱbeȱactivatedȱbyȱaȱuserȱdefinedȱasȱPOȱ Controlȱorȱfromȱtheȱuserȱprogrammingȱmenu.ȱ FollowȱSystemȱEvents:ȱ ȱ ȱ Bellȱ ȱ ȱ Activatesȱwhenȱaȱbellȱisȱtriggered.ȱIfȱaȱbellȱdelayȱwasȱdefined,ȱtheȱprogrammingȱ outputȱwillȱbeȱactivatedȱafterȱtheȱdelayȱperiod.ȱ NoȱTelephoneȱLineȱ ȱ ȱ Activatesȱwhenȱaȱtelephoneȱlineȱfaultȱisȱdetected.ȱIfȱaȱPSTNȱLostȱDelayȱtimeȱ periodȱisȱdefined,ȱtheȱprogrammingȱoutputȱwillȱbeȱactivatedȱafterȱtheȱdelayȱ timeȱ Page 4-35 AgilityȱEngineerȱManualȱ ȱ I/O Expander: Output Parameters Parameter ARCȱCommunicationȱFailȱ ȱ ȱ ActivatesȱwhenȱcommunicationȱwithȱtheȱCentralȱStationȱcannotȱbeȱestablished.ȱ DeactivatesȱafterȱaȱsuccessfulȱcallȱisȱestablishedȱwithȱtheȱCentralȱStation.ȱ GeneralȱFaultȱ ȱ ȱ ȱ ȱ Activatesȱwhenȱaȱsystemȱfaultȱconditionȱisȱdetected.ȱȱ Deactivatesȱafterȱtheȱfaultȱhasȱbeenȱcorrectedȱ MainȱUnitȱȱLowȱbatteryȱ ActivatesȱwhenȱtheȱAgilityȱbatteryȱhasȱinsufficientȱreserveȱcapacityȱandȱtheȱ voltageȱdecreasesȱtoȱ6V.ȱ ACȱLossȱ ȱ ȱ ActivatesȱwhenȱtheȱsourceȱofȱtheȱMainȱPanelȇsȱACȱpowerȱisȱinterrupted.ȱThisȱ activationȱwillȱfollowȱtheȱdelayȱtimeȱdefinedȱinȱtheȱsystemȱcontrolȱtimesȱandȱtheȱ ACȱOffȱDelayȱTimeȱparameter.ȱ Bellȱburglaryȱ ȱ ȱ ActivatesȱtheȱProgrammingȱOutputȱafterȱanyȱbellȱburglaryȱalarmȱinȱanyȱ partitionȱinȱtheȱsystem.ȱ Schedulerȱ ȱ ȱ Theȱprogrammingȱoutputȱwillȱfollowȱtheȱpredefinedȱtimeȱprogrammingȱthatȱisȱ definedȱinȱtheȱschedulerȱofȱtheȱweeklyȱprogramsȱforȱprogrammingȱoutputȱ activation.ȱ Tamperȱ ȱ ȱ ActivatesȱtheȱprogrammingȱoutputȱwhenȱaȱTamperȱoccursȱinȱtheȱsystem.ȱ Duressȱ ActivatesȱtheȱProgrammingȱOutputȱwhenȱaȱduressȱalarmȱisȱinitiatedȱbyȱanyȱ userȱdefinedȱasȱduressȱcode.ȱ GSMȱFaultȱ ActivatesȱtheȱprogrammingȱoutputȱwhenȱthereȱisȱfaultȱinȱtheȱGSMȱmodule.ȱ FollowȱPartitionȱEvents:ȱ ȱ Readyȱ ȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱallȱtheȱselectedȱpartition(s)ȱareȱinȱtheȱ Readyȱstate.ȱ Page 4-36 AgilityȱEngineerȱManualȱ ȱ ȱ I/O Expander: Output Parameters Parameter Setȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱpartition(s)ȱisȱsetȱinȱFullȱ Setȱmode.ȱTheȱprogrammingȱoutputȱwillȱbeȱactivatedȱimmediately,ȱregardlessȱ ofȱtheȱExitȱDelayȱtimeȱperiod.ȱ Unsetȱ ActivatesȱtheȱProgrammingȱOutputȱwhenȱtheȱselectedȱpartition(s)ȱisȱunset.ȱ Alarmȱ ȱ ȱ ActivatesȱtheȱProgrammingȱOutputȱwhenȱanȱalarmȱoccursȱinȱtheȱselectedȱ partition(s).ȱ Intruderȱalarmȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱanȱintrusionȱ(Burglary)ȱalarmȱoccursȱ inȱtheȱselectedȱpartition(s).ȱ Fireȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱaȱfireȱalarmȱisȱtriggeredȱinȱtheȱselectedȱ partition(s)ȱfromȱtheȱkeypadsȱorȱaȱzoneȱdefinedȱasȱFire.ȱ Panicȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱaȱpanicȱalarmȱisȱtriggeredȱinȱtheȱ selectedȱpartition(s)ȱfromȱtheȱkeypads,ȱremoteȱcontrolsȱorȱaȱzoneȱdefinedȱasȱ Panic.ȱ Specialȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱaȱspecialȱalarmȱisȱtriggeredȱinȱtheȱ selectedȱpartition(s)ȱfromȱtheȱkeypadsȱorȱaȱzoneȱdefinedȱasȱSpecialȱ.ȱ Exit/Entryȱ ȱ ȱ ActivatesȱtheȱProgrammingȱOutputȱwhenȱtheȱselectedȱpartition(s)ȱinitiatesȱanȱ Exit/EntryȱDelayȱperiod.ȱ ZoneȱOmitȱ ȱ ȱ ActivatesȱtheȱProgrammingȱOutputȱwhenȱtheȱrelevantȱpartitionsȱareȱinȱSETȱorȱ PARTȱSETȱmodeȱandȱanyȱzoneȱinȱtheȱrelevantȱpartitionsȱisȱomitted.ȱ AutoȱSetȱAlarmȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱthereȱisȱaȱnotȱreadyȱzoneȱatȱtheȱendȱofȱ theȱpreȬȱwarningȱtimeȱduringȱanȱautoȬsetȱprocess.ȱTheȱoutputȱrestoreȱshallȱbeȱonȱ BellȬTimeoutȱorȱatȱuserȱUnset.ȱ ZoneȱLostȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱthereȱisȱaȱlostȱwirelessȱzoneȱinȱtheȱ system.ȱTheȱoutputȱrestoreȱshallȱbeȱonȱBellȬTimeoutȱorȱatȱuserȱUnset.ȱ Page 4-37 AgilityȱEngineerȱManualȱ ȱ I/O Expander: Output Parameters Parameter PartȱSetȱFollowȱ ȱ ȱ ActivatesȱtheȱProgrammingȱOutputȱwhenȱtheȱselectedȱpartition(s)ȱisȱsetȱinȱPartȱ Setȱmode.ȱ ChimeȱFollowȱ ȱ ȱ ActivatesȱtheȱProgrammingȱOutputȱfollowingȱaȱchimeȱsoundȱinȱtheȱselectedȱ partition(s)ȱ BellȱP.ȱSetȱOffȱ ȱ ȱ Thisȱparameterȱcausesȱtheȱprogrammingȱoutputȱtoȱfunctionȱasȱfollows:ȱ InȱFullȱSettingȱmode,ȱtheȱprogrammingȱoutputȱwillȱfollowȱtheȱbellȱ activationȱinȱtheȱdefinedȱpartitions.ȱ InȱPartȱSettingȱmode,ȱtheȱprogrammingȱoutputȱwillȱnotȱbeȱactivated.ȱ Bellȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱoneȱofȱtheȱdefinedȱpartitionsȱisȱinȱ Alarmȱmodeȱandȱtheȱbellȱisȱtriggered.ȱThisȱenablesȱtheȱconnectionȱofȱdifferentȱ soundersȱtoȱdifferentȱpartitions.ȱ FollowȱZoneȱEvents:ȱ Zoneȱ ȱ ȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱzoneȱisȱtripped.ȱȱ TheȱtrippedȱzoneȱneedȱnotȱbeȱsetȱtoȱtriggerȱtheȱProgrammingȱOutput.ȱ Alarmȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱzoneȱcausesȱanȱalarm.ȱ Setȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱzonesȱareȱset.ȱ Unsetȱ ȱ ȱ Activatesȱtheȱprogrammingȱoutputȱwhenȱtheȱselectedȱzonesȱareȱunset.ȱ FollowȱUserȱCode:ȱ ȱ ȱ DefinesȱtheȱUserȱCode(s)ȱforȱtriggeringȱtheȱselectedȱPO.ȱTheȱactivationȱofȱtheȱ ȱȱkeyȱtoȱtoggleȱ POȱisȱperformedȱfromȱtheȱUserȱActivitiesȱmenu.ȱUseȱtheȱ betweenȱ[Y]ȱYESȱorȱ[N]ȱNOȱforȱeachȱuserȱchosenȱtoȱtripȱtheȱdesignatedȱ ProgrammingȱOutput.ȱ Patternȱ ȱ ȱ Forȱeachȱoutputȱyouȱneedȱtoȱdefineȱtheȱpatternȱofȱoperation.ȱTheȱavailableȱoptionsȱȱare:ȱ Page 4-38 AgilityȱEngineerȱManualȱ ȱ ȱ I/O Expander: Output Parameters Parameter PulseȱN/Oȱȱ(NormallyȱOpen)ȱ ȱ ȱ TheȱprogrammingȱoutputȱisȱalwaysȱDeactivatedȱ(N/O)ȱbeforeȱitȱisȱtriggeredȱ (pulledȱup).ȱ Whenȱtriggered,ȱitȱactivatesȱ(pulledȱdown)ȱforȱtheȱPulseȱDurationȱspecified,ȱ thenȱdeactivatesȱautomatically.ȱ LatchedȱN/Oȱȱ(NormallyȱOpen)ȱ ȱ ȱ TheȱProgrammingȱOutputȱisȱalwaysȱDeactivatedȱ(N/O)ȱbeforeȱitȱisȱtriggeredȱ (pulledȱup).ȱWhenȱtriggered,ȱitȱactivatesȱ(pulledȱdown)ȱandȱremainsȱactivatedȱ (latched)ȱuntilȱtheȱoperationȱisȱrestored.ȱ PulseȱN/Cȱȱ(NormallyȱClosed)ȱ ȱ ȱ TheȱprogrammingȱoutputȱisȱalwaysȱActivatedȱ(N/C)ȱbeforeȱitȱisȱtriggeredȱ (pulledȱdownȱtoȱnegative).ȱWhenȱtriggered,ȱitȱdeactivatesȱforȱtheȱPulseȱDurationȱ specifiedȱbelowȱandȱthenȱreactivatesȱautomatically.ȱ LatchedȱN/Cȱȱ(NormallyȱClose)ȱ ȱ ȱ TheȱProgrammingȱOutputȱisȱalwaysȱActivatedȱ(N/C)ȱbeforeȱitȱisȱtriggeredȱ (pulledȱdownȱtoȱnegative).ȱWhenȱtriggered,ȱitȱdeactivatesȱandȱremainsȱ deactivatedȱ(latched)ȱuntilȱtheȱoperationȱisȱrestored.ȱ Activationȱȱ/ȱDeactivationȱ ȱ ȱ Whenȱtheȱprogrammingȱoutputȱisȱfollowingȱmoreȱthanȱoneȱpartitionȱorȱzone,ȱtheȱ engineerȱcanȱchooseȱtheȱlogicȱofȱtheȱProgrammingȱOutputȱactivationȱasȱfollows:ȱ IfȱtheȱpatternȱoperationȱofȱtheȱoutputȱisȱdefinedȱasȱLatchȱN/OȱorȱLatchȱN/C,ȱtheȱ activationȱandȱdeactivationȱofȱtheȱoutputsȱcanȱȱfollowȱeitherȱafterȱallȱtheȱ Partitions/ZonesȱorȱafterȱanyȱofȱtheȱPartitions/Zones.ȱ IfȱtheȱPatternȱoperationȱofȱtheȱoutputȱisȱdefinedȱasȱPulseȱN/OȱorȱPulseȱN/C,ȱtheȱ activationȱofȱtheȱoutputsȱcanȱȱfollowȱeitherȱafterȱallȱtheȱPartitions/Zonesȱorȱafterȱanyȱ ofȱtheȱPartitions/Zones.ȱTheȱdeactivationȱoperationȱfollowsȱtheȱdefinedȱtimeȱperiod.ȱ PulseȱDurationȱLengthȱ 05ȱsecȱ 01Ȭ90ȱ TheȱtimeȱthatȱanȱoutputȱdefinedȱasȱPulsedȱN.OȱorȱPulsedȱN.Cȱwillȱbeȱactivated.ȱAtȱtheȱ endȱofȱtheȱpulseȱdurationȱtheȱoutputȱreactivatesȱautomatically.ȱ Page 4-39 AgilityȱEngineerȱManualȱ ȱ XȬ10ȱOutputsȱ TheȱwirelessȱI/OȱexpanderȱenablesȱtheȱsystemȱtoȱcontrolȱXȱ–ȱ10ȱdevices.ȱTheȱI/Oȱexpanderȱ convertsȱtheȱinformationȱsentȱfromȱtheȱprogrammableȱprogrammingȱoutputȱintoȱtheȱXȱ–ȱ10ȱ protocol.ȱUpȱtoȱsixteenȱXȬ10ȱdevicesȱcanȱbeȱactivated.ȱTheseȱareȱrecognizedȱinȱtheȱsystemȱasȱ outputsȱ5Ȭ20.ȱ I/O Expander: X-10 Outputs Parameter Default Labelȱ Range ȱ ȱ ȱ ȱ ȱ ȱ 05ȱsecȱ 01Ȭ90ȱ Aȱlabelȱidentifiesȱtheȱoutputȱinȱtheȱsystemȱ Typeȱ Referȱtoȱtheȱexplanationȱunderȱtheȱprogrammingȱoutputȱsection.ȱ Patternȱ Referȱtoȱtheȱexplanationȱunderȱtheȱprogrammingȱoutputȱsection.ȱ PulseȱLengthȱȱȱ Referȱtoȱtheȱexplanationȱunderȱtheȱprogrammingȱoutputȱsection.ȱ Parametersȱ TheȱfollowingȱtableȱdescribesȱtheȱgeneralȱparametersȱforȱtheȱI/Oȱmodule.ȱ I/O Expander: Parameters Parameter Default SerialȱNumberȱ ȱ Range ȱ TheȱinternalȱIDȱnumberȱofȱtheȱI/OȱExpander.ȱEachȱwirelessȱdeviceȱhasȱitsȱownȱuniqueȱ serialȱnumber.ȱ Controlsȱ I/OȱExpanderȱSupervisionȱ ȱ ȱ ȱ ȱ ȱ ȱ ChooseȱifȱtheȱI/OȱExpanderȱwillȱbeȱsupervisedȱorȱnot.ȱ QuickȱOutputȱOperationȱ AȱuserȱcanȱactivateȱaȱPOȱfromȱtheȱbidirectionalȱremoteȱcontrolȱorȱkeysȱ ȱonȱtheȱwirelessȱkeypadȱwithoutȱtheȱneedȱtoȱenterȱhisȱuserȱcode.ȱ XȬ10ȱHouseȱIDȱ ȱ ȱ Definesȱtheȱhouseȱcode,ȱwhichȱmatchesȱtheȱcodeȱdefinedȱbyȱtheȱXȬ10ȱmodules.ȱȱ POȱDTMFȱControlȱ ȱ ȱ TheȱAgilityȱenablesȱtoȱactivateȱ8ȱprogrammingȱoutputsȱfromȱremoteȱDTMFȱphone.ȱToȱ operateȱaȱPOȱviaȱtheȱtelephoneȱyouȱmustȱassignȱaȱspecificȱPOȱtoȱaȱdigitȱonȱtheȱphone.ȱȱ Page 4-40 AgilityȱEngineerȱManualȱ ȱ ȱ 2.3 Identification Thisȱoptionȱprovidesȱtheȱabilityȱtoȱidentifyȱtheȱserialȱnumberȱofȱaȱwirelessȱdeviceȱinȱtheȱ systemȱfromȱaȱkeypadȱorȱfromȱtheȱconfigurationȱsoftware.ȱȱ Whenȱusingȱaȱkeypadȱfollowȱthisȱprocedure:ȱ GoȱtoȱProgrammingȱÆȱRadioȱDevicesȱMenuȱÆȱIdentificationȱandȱpressȱ followingȱmessageȱappearsȱonȱtheȱkeypadȱLCD:ȱ .ȱTheȱ ȱ Pressȱonȱtheȱdevice’sȱLearnȱmode.ȱTheȱserialȱnumberȱofȱtheȱrelevantȱdeviceȱappearsȱonȱ theȱkeypadȱLCD.ȱ Page 4-41 AgilityȱEngineerȱManualȱ ȱ 3. Programming: Codes Menu TheȱCodesȱmenuȱprovidesȱtheȱabilityȱdoȱdefineȱparametersȱandȱcodesȱforȱtheȱsystemȱusers.ȱȱ 3.1 User Userȱrightsȱcanȱbeȱdefinedȱbyȱallocatingȱeachȱuserȱaȱspecificȱauthorityȱlevelȱandȱspecificȱ partitions.ȱUpȱtoȱ32ȱusersȱcanȱbeȱdefinedȱinȱtheȱsystem.ȱ Codes: User Codes Parameter Default Labelsȱ ȱ Usedȱtoȱdefineȱtheȱuserȱname.ȱUpȱtȱoȱ32ȱcharactersȱcanȱbeȱused.ȱ Partitionȱ ȱ Enablesȱyouȱtoȱassignȱtheȱpartition(s)ȱinȱwhichȱallȱUserȱCodesȱ(exceptȱforȱtheȱGrandȱ Master)ȱwillȱoperate.ȱ AuthorityȱLevelȱȱ ȱ Allocateȱanȱauthorityȱlevelȱtoȱaȱuserȱaccordingȱtoȱtheȱfollowingȱlist:ȱȱ User:ȱThereȱareȱnoȱrestrictionsȱinȱtheȱnumberȱofȱUserȱCodesȱ(asȱlongȱasȱtheyȱdoȱ notȱexceedȱtheȱnumberȱofȱcodesȱremainingȱinȱtheȱsystem).ȱTheȱUserȱhasȱaccessȱtoȱ theȱfollowing:ȱȱ Settingȱandȱunsettingȱ Omittingȱzonesȱ Viewingȱsystemȱstatus,ȱfault,ȱandȱalarmȱmemoryȱ ActivatingȱdesignatedȱProgrammingȱOutputsȱ Changingȱhis/herȱownȱUserȱCodeȱ Settingȱkeypadȇsȱsettingsȱ Cleaner:ȱTheȱCleanerȱCodeȱisȱaȱtemporaryȱcode,ȱwhichȱisȱtoȱbeȱimmediatelyȱ deletedȱfromȱtheȱsystemȱasȱsoonȱasȱitȱisȱusedȱtoȱset.ȱThisȱcodeȱisȱtypicallyȱusedȱforȱ maids,ȱhomeȱattendants,ȱandȱrepairmenȱwhoȱmustȱenterȱtheȱpremisesȱbeforeȱtheȱ owner(s)ȱarrive.ȱTheseȱcodesȱareȱusedȱasȱfollows:ȱ ForȱoneȬtimeȱsettingȱinȱoneȱorȱmoreȱpartitionsȱ Ifȱfirstȱusedȱtoȱunsetȱtheȱsystem,ȱtheȱcodeȱmayȱbeȱusedȱonceȱforȱsubsequentȱ settingȱ SetȱOnly:ȱThereȱareȱnoȱrestrictionsȱinȱtheȱnumberȱofȱSetȱOnlyȱCodesȱ(asȱlongȱasȱ theyȱdonȇtȱexceedȱtheȱnumberȱofȱcodesȱremainingȱinȱtheȱsystem).ȱSetȱOnlyȱCodesȱ areȱusefulȱforȱworkersȱwhoȱarriveȱwhenȱtheȱpremisesȱareȱalreadyȱopen,ȱbutȱ becauseȱtheyȱareȱlastȱtoȱleave,ȱtheyȇreȱgivenȱtheȱresponsibilityȱtoȱcloseȱtheȱ premisesȱandȱsetȱtheȱsystem.ȱTheȱusersȱwithȱSetȱOnlyȱCodesȱhaveȱaccessȱforȱ settingȱoneȱorȱmoreȱpartitions.ȱ ȱ Page 4-42 AgilityȱEngineerȱManualȱ ȱ ȱ Codes: User Codes Parameter Default Duress:ȱWhenȱcoercedȱintoȱunsettingȱtheȱsystem,ȱtheȱuserȱcanȱcomplyȱwithȱtheȱ intruderȇsȱwishesȱwhileȱsendingȱaȱsilentȱduressȱalarmȱtoȱtheȱCentralȱStation.ȱToȱ doȱso,ȱaȱspecialȱduressȱcodeȱmustȱbeȱused,ȱwhichȱwhenȱused,ȱwillȱunsetȱtheȱ systemȱinȱtheȱregularȱmanner,ȱwhileȱsimultaneouslyȱtransmittingȱtheȱduressȱ alarm.ȱInȱanyȱotherȱsituationȱtheȱDuressȱauthorityȱlevelȱbehavesȱasȱtheȱsameȱasȱ theȱUserȱauthorityȱlevel.ȱ 3.2 Grand Master TheȱGrandȱMasterȱCodeȱisȱusedȱbyȱtheȱsystemȇsȱownerȱandȱisȱtheȱhighestȱAuthorityȱLevel.ȱȱ Theȱownerȱcanȱset/changeȱtheȱGrandȱMasterȱCode.ȱȱ Default:ȱ1234ȱ Note:ȱInȱtheȱConfigurationȱsoftwareȱtheȱGrandȱMasterȱisȱidentifiedȱasȱCodeȱ00.ȱ 3.3 Engineer TheȱEngineerȱCodeȱprovidesȱaccessȱtoȱtheȱEngineerȱProgrammingȱmenu,ȱallowingȱ modificationȱofȱallȱsystemȱparameters.ȱTheȱEngineerȱCodeȱisȱusedȱbyȱtheȱAgilityȱ installationȱcompanyȱtechnicianȱtoȱprogramȱtheȱsystem.ȱ TheȱEngineerȱcanȱchangeȱtheȱEngineerȱCode.ȱȱ Default:ȱ0132ȱ 3.4 Sub-Engineer TheȱSubȬEngineerȱCodeȱallowsȱlimitedȱaccessȱtoȱselectedȱparametersȱfromȱtheȱEngineerȱ Programmingȱmenu.ȱItȱisȱusedȱbyȱaȱtechnicianȱsentȱbyȱtheȱAgilityȱinstallationȱcompanyȱtoȱ carryȱoutȱrestrictedȱtasksȱdefinedȱatȱtheȱtimeȱofȱsystemȱinstallationȱbyȱtheȱinstallationȱ technician.ȱTheȱSubȬEngineerȱcanȱaccessȱwithȱhisȱcodeȱonlyȱthoseȱprogrammingȱmenusȱ predefinedȱforȱhisȱaccess.ȱDefault:ȱ0232ȱ TheȱSubȬEngineerȱisȱprohibitedȱtoȱaccessȱtheȱfollowingȱparameters:ȱ x DefaultȱEnableȱ x ARCȱEnableȱ x ConfigurationȱSoftwareȱEnableȱ x CodeȱLengthȱ x EngineerȱCodeȱ Note:ȱInȱtheȱAgilityȱConfigurationȱSoftware,ȱtheȱConfigurationȱSoftwareȱandȱARCȱmenusȱareȱunavailableȱtoȱ theȱsubȬengineer.ȱ ȱ Page 4-43 AgilityȱEngineerȱManualȱ ȱ 3.5 Code Length TheȱCodeȱLengthȱspecifiesȱtheȱminimumȱnumberȱofȱdigitsȱrequested.ȱDefault:ȱ4ȱdigitsȱ Notes:ȱȱ WhenȱyouȱchangeȱtheȱCodeȱLengthȱparameter,ȱallȱUserȱCodesȱareȱdeletedȱandȱmustȱbeȱreȬprogrammedȱorȱ downloaded.ȱ Forȱaȱ6ȬdigitȱCodeȱLengthȱsystem,ȱ4Ȭdigitȱdefaultȱcodesȱlikeȱ1Ȭ2Ȭ3Ȭ4ȱ(GrandȱMaster),ȱ0Ȭ1Ȭ3Ȭ2ȱ(Engineer),ȱandȱ0Ȭ 2Ȭ3Ȭ2ȱ(SubȬEngineer)ȱbecomeȱ1Ȭ2Ȭ3Ȭ4Ȭ0Ȭ0,ȱ0Ȭ1Ȭ3Ȭ2Ȭ0Ȭ0,ȱandȱ0Ȭ2Ȭ3Ȭ2Ȭ0Ȭ0,ȱrespectively.ȱ IfȱyouȱchangeȱtheȱCodeȱLengthȱbackȱtoȱ4ȱdigits,ȱtheȱsystemȱcodesȱareȱrestoredȱtoȱtheȱdefaultȱ4Ȭdigitȱcodes.ȱ ȱ EN50131Ȭ3ȱstandardȱspecifications:ȱ ȱȱAllȱcodeȱlengthȱareȱ4ȱdigits:ȱxxxxȱ ȱȱForȱeachȱdigitȱ0Ȭ9ȱcanȱbeȱusedȱ ȱȱAllȱcodesȱfromȱ0000ȱtoȱ9999ȱareȱacceptableȱ ȱȱInvalidȱcodesȱcannotȱbeȱcreatedȱsinceȱafterȱ4ȱdigitsȱareȱtyped,ȱtheȱȈEnterȈȱisȱautomatic.ȱȱ ȱȱȱCodesȱareȱrejectedȱwhenȱtryingȱtoȱcreateȱaȱcodeȱthatȱdoesȱnotȱexist.ȱ 3.6 DTMF Code Thisȱisȱaȱtelephoneȱremoteȱaccessȱcodeȱmadeȱupȱofȱtwoȱdigitsȱthatȱenablesȱentryȱintoȱtheȱ systemȱwhenȱdialingȱinȱfromȱaȱremoteȱnumber.ȱȱ Defaultȱcode=00ȱ 3.7 Parent Control TheȱParentȱControlȱoptionȱisȱusedȱtoȱmonitorȱtheȱactivityȱofȱchildren.ȱThisȱoptionȱallowsȱallȱ usersȱtoȱmonitorȱwhenȱtheȱchildrenȱarriveȱhomeȱandȱunsetȱtheȱsystemȱorȱwhenȱtheyȱsetȱtheȱ systemȱinȱFullȱSetȱmode.ȱWithȱeachȱactivation/deactivationȱofȱtheȱsystemȱaȱmessageȱisȱsentȱ toȱaȱspecifiedȱFollowȱMeȱnumber.ȱ ȱȱkeyȱtoȱtoggleȱbetweenȱ[Y]ȱYESȱorȱ[N]ȱNOȱforȱeachȱuserȱchosenȱtoȱbeȱassignedȱ Useȱtheȱ withȱtheȱparentȱcontrolȱfeature.ȱȱ Page 4-44 AgilityȱEngineerȱManualȱ ȱ ȱ 4. Programming: Communication Menu TheȱCommunicationȱmenuȱprovidesȱaccessȱtoȱsubmenusȱandȱtheirȱrelatedȱparametersȱthatȱ enableȱtheȱsystemȱtoȱestablishȱcommunicationȱwithȱtheȱARC,ȱFollowȱMeȱorȱ Upload/Download.ȱ TheȱCommunicationȱmenuȱisȱdividedȱintoȱtheȱfollowingȱsubȬmenus:ȱ 1.ȱMethodȱ 2.ȱARCȱ 2.ȱConfigurationȱSoftwareȱ 3.ȱFollowȬMeȱ 4.1 Method Thisȱoptionȱallowsȱyouȱtoȱconfigureȱtheȱparametersȱofȱtheȱcommunicationȱmethodsȱ (channels)ȱofȱtheȱAgility.ȱ3ȱoptionalȱcommunicationȱtypesȱareȱavailable:ȱ 1.ȱPSTNȱ 2.ȱGSMȱ 3.ȱIPȱ 4.1.1 PSTN TheȱPSTNȱscreenȱcontainsȱparametersȱforȱtheȱcommunicationȱofȱtheȱAgilityȱoverȱtheȱPSTNȱ network Communication Type: PSTN Parameter Default Timersȱ Range ȱ ȱ TimersȱrelatedȱtoȱcommunicationȱthroughȱtheȱPSTNȱchannelȱ PSTNȱLostȱDelayȱ 04ȱ 00Ȭ20ȱminutesȱ TheȱtimeȱafterȱwhichȱtheȱsystemȱwillȱregardȱtheȱPSTNȱlineȱasȱlost.ȱThisȱtimeȱalsoȱ specifiesȱtheȱdelayȱbeforeȱreportingȱtheȱeventȱintoȱtheȱeventȱlogȱorȱoperatingȱaȱ programmingȱoutputȱthatȱfollowsȱthisȱevent.ȱȱ 00ȱindicatesȱnoȱsupervisionȱofȱtheȱphoneȱline.ȱ WaitȱforȱDialȱToneȱ 3ȱ 0Ȭ255ȱsecondsȱ Theȱnumberȱofȱsecondsȱtheȱsystemȱwaitsȱtoȱdetectȱaȱdialȱtone.ȱȱ Controlsȱ AlarmȱLineȱCutȱ ȱ ȱ ȱ ȱ YES:ȱActivatesȱtheȱexternalȱsoundersȱifȱtheȱlandȱline,ȱconnectedȱtoȱtheȱAgilityȱ panelȱisȱcutȱorȱtheȱtelephoneȱserviceȱisȱinterruptedȱforȱtheȱtimeȱdefinedȱinȱtheȱ PSTNȱLostȱtimeȱparameter.ȱȱ NO:ȱNoȱactivationȱoccurs.ȱ Page 4-45 AgilityȱEngineerȱManualȱ ȱ Communication Type: PSTN Parameter Default AnsweringȱMachineȱOverrideȱ Range ȱ ȱ YES:ȱTheȱAnsweringȱMachineȱOverrideȱisȱenabled,ȱasȱfollows:ȱ Theȱconfigurationȱsoftwareȱatȱtheȱalarmȱcompanyȱcallsȱtheȱaccount.ȱ Theȱsoftwareȱhangsȱupȱafterȱoneȱringȱbyȱtheȱconfigurationȱoperator.ȱ Withinȱoneȱminute,ȱtheȱsoftwareȱcallsȱagain.ȱ Theȱsystemȱisȱprogrammedȱtoȱpickȱupȱthisȱsecondȱcallȱonȱtheȱfirstȱring,ȱthusȱ omittingȱanyȱinteractionȱwithȱtheȱansweringȱmachine.ȱ Note:ȱThisȱfeatureȱisȱusedȱtoȱpreventȱinterferenceȱfromȱanȱansweringȱmachineȱwithȱremoteȱ configurationȱoperations.ȱ NO:ȱTheȱAnsweringȱMachineȱOverrideȱisȱdisabled,ȱandȱcommunicationȱtakesȱ placeȱinȱtheȱstandardȱmanner.ȱ Parametersȱ RingsȱtoȱAnswerȱȱ ȱ ȱ 12ȱ 01ȱtoȱ15ȱ Theȱnumberȱofȱringsȱbeforeȱtheȱsystemȱanswersȱanȱincomingȱcallȱȱ Areaȱcodeȱ ȱ ȱ Theȱsystemȱareaȱtelephoneȱcode.ȱThisȱcodeȱwillȱbeȱdeletedȱfromȱaȱtelephoneȱ numberȱwhileȱtheȱsystemȱtriesȱtoȱdialȱtheȱnumberȱthroughȱtheȱGSMȱnetwork.ȱȱ PBXȱPrefixȱ ȱ ȱ Aȱnumberȱdialedȱtoȱaccessȱanȱoutgoingȱlineȱwhenȱtheȱsystemȱisȱconnectedȱtoȱaȱ PrivateȱBranchȱExchangeȱ(PBX)ȱandȱnotȱdirectlyȱtoȱaȱPSTNȱline.ȱThisȱnumberȱ willȱbeȱaddedȱautomaticallyȱbyȱtheȱsystemȱwhileȱtryingȱtoȱcallȱfromȱaȱPSTNȱline.ȱȱ 4.1.2 GSM TheȱGSMȱscreenȱcontainsȱparametersȱforȱtheȱcommunicationȱofȱtheȱsystemȱoverȱtheȱ GSM/GPRSȱnetwork.ȱ Method: GSM Parameter Default Range Timersȱ ȱ ȱ AllowsȱtoȱprogramȱtimersȱrelatedȱtoȱoperationȱwithȱtheȱGSMȱmoduleȱ GSMȱLostȱ 10ȱmin 001Ȭ255ȱminȱ TheȱtimeȱafterȱwhichȱtheȱGSMȱmoduleȱregardsȱtheȱGSMȱnetworkȱasȱloss.ȱ NetworkȱlossȱisȱdefinedȱasȱRSSIȱlevelȱbelowȱtheȱlevelȱdefinedȱGSMȱNetworkȱ Sensitivityȱparameter.ȱ Page 4-46 AgilityȱEngineerȱManualȱ ȱ Method: GSM Parameter Default SIMȱExpireȱ Range 00ȱ 00Ȭ36ȱmonthsȱ AȱPreȬpaidȱSIMȱcardȱhasȱaȱdefinedȱlifeȱlengthȱdefinedȱbyȱtheȱprovider.ȱAfterȱ eachȱchargingȱofȱtheȱSIM,ȱtheȱuserȱwillȱhaveȱtoȱmanuallyȱresetȱtheȱexpirationȱ timeȱofȱtheȱSIMȱcard.ȱAȱnotificationȱwillȱbeȱdisplayedȱonȱtheȱwirelessȱkeypadȱ whenȱaskingȱforȱstatusȱindication.ȱ SetȱtheȱSIMȱexpiringȱdateȱ(inȱmonths)ȱusingȱtheȱnumericȱkeys,ȱaccordingȱtoȱtheȱ timeȱgivenȱbyȱtheȱprovider.ȱ ARCȱKeepȱAliveȱ(Polling)ȱ 00000ȱ 0Ȭ65535ȱtimesȱ Theȱtimeȱperiodȱthatȱtheȱsystemȱwillȱestablishȱautomaticȱcommunicationȱ (polling)ȱwithȱtheȱARCȱoverȱGPRS,ȱinȱorderȱtoȱcheckȱtheȱconnection.ȱ 3ȱpollingȱtimesȱcanȱbeȱdefined:ȱPrimary,ȱSecondaryȱandȱBackup.ȱForȱeachȱtimeȱ periodȱdefineȱtheȱnumberȱofȱunitsȱbetweenȱ1Ȭȱ65535.ȱEachȱunitȱrepresentsȱaȱtimeȱ frameȱofȱ10ȱseconds.ȱ Note:ȱWhenȱusingȱtheȱpollingȱfeatureȱthroughȱGPRSȱtheȱARCȱchannelȱparameterȱmustȱbeȱ definedȱasȱGPRSȱonly.ȱ TheȱreportȱcodeȱforȱARCȱpollingȱisȱ999ȱ(ContactȱID)ȱorȱZZȱ(SIA)ȱȱ TheȱuseȱofȱtheseȱtimeȱperiodsȱdependsȱonȱtheȱreportingȱorderȱtoȱtheȱARCȱ definedȱbyȱtheȱReportȱSplitȱARCȱUrgentȱparameterȱ(See:ȱ[4]Communicationȱ>ȱ [2]ARCȱ>ȱ[7]ReportȱSplit)ȱ Primary:ȱThisȱtimeȱperiodȱisȱusedȱwhenȱtheȱARCȱchannelȱisȱdefinedȱasȱGPRSȱ OnlyȱandȱtheȱReportȱSplitȱparameterȱisȱnotȱdefinedȱasȱ1stȱbackupȱ2nd.ȱ Secondary:ȱThisȱtimeȱperiodȱisȱusedȱwhenȱtheȱARCȱ2ȱchannelȱisȱdefinedȱasȱ IPÆGPRSȱOnlyȱandȱtheȱReportȱSplitȱparameterȱisȱdefinedȱasȱ1stȱbackupȱ2nd.ȱ Backup:ȱThisȱtimeȱperiodȱwillȱbeȱassignedȱtoȱtheȱbackupȱchannelȱinȱtheȱ followingȱcase:ȱ ȱȱȱARCȱ2ȱchannelȱisȱdefinedȱasȱIPÆGPRSȱOnlyȱ ȱȱȱReportȱSplitȱparameterȱisȱdefinedȱasȱ1stȱbackupȱ2ndȱ ȱȱȱTheȱcommunicationȱwithȱARCȱ1ȱisȱdisconnected.ȱ GPRSȱ ȱ ȱ ȱ AllowsȱprogrammingȱparametersȱthatȱrelateȱforȱtheȱcommunicationȱoverȱtheȱGPRSȱ network.ȱ Page 4-47 ȱ AgilityȱEngineerȱManualȱ ȱ Method: GSM Parameter Default AccessȱPointȱNetworkȱ(APN)ȱCodeȱ Range ȱ ȱ ToȱestablishȱaȱconnectionȱtoȱtheȱGPRSȱnetworkȱanȱAPNȱ(AccessȱPointȱName)ȱ codeȱisȱrequired.ȱTheȱAPNȱcodeȱdiffersȱfromȱcountryȱtoȱcountryȱandȱfromȱoneȱ providerȱtoȱanotherȱ(theȱAPNȱcodeȱisȱprovidedȱbyȱyourȱcellularȱprovider).ȱ TheȱsystemȱsupportsȱanȱAPNȱcodeȱfieldȱofȱupȱtoȱ30ȱalphanumericȱcharactersȱandȱ symbolsȱ(!,ȱ&,ȱ?ȱetc).ȱ APNȱUserȱNameȱ ȱ ȱ EnterȱAPNȱuserȱnameȱ(ifȱrequired).ȱTheȱUserȱnameȱisȱprovidedȱbyȱyourȱ provider.ȱTheȱsystemȱsupportsȱaȱuserȱnameȱfieldȱofȱupȱtoȱ20ȱalphanumericȱ charactersȱandȱsymbolsȱ(!,ȱ&,ȱ?ȱetc).ȱ APNȱPasswordȱ ȱ ȱ EnterȱtheȱAPNȱpasswordȱ(upȱtoȱ20ȱalphanumericȱcharactersȱandȱsymbols.)ȱasȱ providedȱbyȱyourȱproviderȱ(ifȱrequired).ȱ EȬmailȱ ȱ ȱ TheȱfollowingȱprogrammingȱparametersȱareȱusedȱtoȱenableȱsendingȱFollowȱMeȱeventȱ messagesȱbyȱeȬmailȱthroughȱGPRS.ȱ Note:ȱToȱenableȱeȬmailȱmessaging,ȱtheȱGPRSȱparametersȱhaveȱtoȱbeȱdefined.ȱ MailȱHostȱ ȱ ȱ TheȱIPȱaddressȱorȱtheȱhostȱnameȱofȱtheȱSMTPȱmailȱserverȱ SMTPȱPortȱ ȱ ȱ ȱ ȱ TheȱportȱaddressȱofȱtheȱSMTPȱmailȱserverȱ Emailȱaddressȱ TheȱEmailȱaddressȱthatȱidentifiesȱtheȱsystemȱtoȱtheȱmailȱrecipientȱ.ȱȱ SMTPȱUserȱNameȱ ȱ ȱ AȱnameȱidentifyingȱtheȱuserȱtoȱtheȱSMTPȱmailȱserver.ȱTheȱuserȱnameȱfieldȱcanȱ includeȱupȱtoȱ10ȱalphanumericȱcharactersȱandȱsymbolsȱ(!,ȱ&,ȱ?ȱetc).ȱProvisionȱforȱ futureȱfunctionalityȱ SMTPȱPasswordȱ ȱ ȱ TheȱpasswordȱauthenticatingȱtheȱuserȱtoȱtheȱSMTPȱmailȱserver.ȱTheȱpasswordȱ canȱincludeȱupȱtoȱ10ȱalphanumericȱcharactersȱandȱsymbolsȱ(!,ȱ&,ȱ?ȱetc).ȱProvisionȱ forȱfutureȱfunctionalityȱ Page 4-48 AgilityȱEngineerȱManualȱ ȱ ȱ Method: GSM Parameter Default Range Controlsȱ ȱ ȱ AllowsȱtoȱcontrolȱtimersȱrelatedȱtoȱoperationȱwithȱtheȱGSMȱmoduleȱ CallerȱIDȱ ȱ ȱ TheȱCallerȱIDȱfunctionȱenablesȱtoȱrestrictȱSMSȱremoteȱcontrolȱoperationsȱtoȱtheȱ predefinedȱfollowȱmeȱphoneȱnumbers.ȱIfȱtheȱincomingȱnumberȱisȱrecognizedȱasȱ oneȱofȱtheȱFollowȱMeȱnumbers,ȱtheȱoperationȱwillȱbeȱexecuted.ȱ DisableȱGSMȱ ȱ ȱ YES:ȱTheȱsystemȱwillȱdisableȱtheȱGSM/GPRSȱmoduleȱfromȱanyȱactivity.ȱȱ NO:ȱGSM/GPRSȱmoduleȱisȱenabledȱinȱtheȱsystem.ȱ Parametersȱ ȱ ȱ AllowsȱtoȱprogramȱtimersȱrelatedȱtoȱtheȱoperationȱwithȱtheȱGSMȱmodule.ȱ SIMȱPINȱCodeȱ ȱ ȱ TheȱPINȱ(PersonalȱIdentityȱNumber)ȱcodeȱisȱaȱ4ȱtoȱ8ȱdigitȱnumberȱgivingȱyouȱ accessȱtoȱtheȱGSMȱnetworkȱprovider.ȱ Note:ȱYouȱcanȱcancelȱtheȱPINȱcodeȱrequestȱfunctionȱbyȱinsertingȱtheȱSIMȱcardȱintoȱaȱregularȱȱ mobileȱphoneȱandȱaccordingȱtoȱtheȱphoneȱsettings,ȱdisableȱthisȱfunction.ȱ SMSȱCenterȱPhoneȱ ȱ ȱ Aȱtelephoneȱnumberȱofȱtheȱmessageȱdeliveryȱcenter.ȱThisȱnumberȱcanȱbeȱ obtainedȱfromȱtheȱnetworkȱoperator.ȱȱ GSMȱNetworkȱSensitivityȱ(RSSI)ȱ ȱ ȱ Setȱtheȱminimumȱacceptableȱnetworkȱsignalȱlevelȱ(RSSIȱlevel). ȱ Options:ȱDisabledȱ(Noȱtroublesȱforȱlowȱsignalȱreception)ȱ/ȱLowȱsignalȱ/ȱHighȱ signalȱȱ SIMȱNumberȱ ȱ ȱ TheȱSIMȱphoneȱnumber.ȱTheȱsystemȱusesȱthisȱparameterȱtoȱreceiveȱtheȱtimeȱfromȱ theȱGSMȱnetworkȱinȱorderȱtoȱupdateȱtheȱsystemȱtime. Page 4-49 AgilityȱEngineerȱManualȱ ȱ Method: GSM Parameter Default PrepaidȱSIMȱCardȱ Range ȱ ȱ AllowsȱprogrammingȱparametersȱthatȱwillȱbeȱusedȱwhenȱaȱprepaidȱSIMȱcardȱisȱusedȱinȱ theȱsystem.ȱ ȱȱȱȱȱȱȱȱGetȱCreditȱbyȱȱ ȱ ȱ Dependingȱonȱtheȱlocalȱnetworkȱprovider,ȱtheȱuserȱcanȱreceiveȱtheȱcreditȱlevelȱofȱtheȱ prepaidȱSIMȱcardȱbyȱsendingȱaȱpredefinedȱSMSȱcommandȱtoȱaȱdefinedȱnumberȱorȱbyȱ callingȱaȱpredefinedȱnumberȱthroughȱtheȱvoiceȱchannel.ȱȱTheȱactivationȱofȱtheȱcreditȱ requestȱcanȱbeȱdoneȱbyȱtheȱGrandȱMaster.ȱ SMSȱCreditȱMessage:ȱTypeȱinȱtheȱmessageȱcommandȱasȱdefinedȱbyȱtheȱ providerȱȱandȱtheȱprovider’sȱphoneȱnumberȱtoȱwhichȱtheȱcreditȱlevelȱSMSȱ messageȱrequestȱwillȱbeȱsent.ȱ VoiceȱCredit:ȱTypeȱinȱtheȱprovider’sȱphoneȱnumberȱtoȱwhichȱaȱcallȱwillȱbeȱ establishedȱ ServiceȱCommand:ȱTypeȱinȱtheȱserviceȱcommandȱmessageȱasȱdefinedȱbyȱtheȱ providerȱȱ ȱȱȱȱȱȱȱPhoneȱtoȱGetȱCreditȱMessageȱ ȱ ȱ ȱȱȱȱȱȱȱTheȱprovider’sȱphoneȱnumberȱtoȱwhichȱtheȱcreditȱlevelȱSMSȱmessageȱrequestȱȱ ȱȱȱȱȱȱȱwillȱbeȱsentȱtoȱorȱaȱcallȱwillȱbeȱestablished,ȱdependingȱonȱtheȱselectionȱinȱtheȱȱȱ ȱȱȱȱȱȱȱGetȱCreditȱbyȱparameter.ȱ ȱȱȱȱȱȱȱȱPhoneȱtoȱReceiveȱSMSȱCreditȱMessage:ȱ ȱ ȱ Theȱprovider’sȱtelephoneȱnumberȱfromȱwhichȱanȱautomaticȱSMSȱcreditȱstatusȱ messageȱwillȱbeȱsentȱfrom.ȱ 4.1.3 IP Communication Type: IP Parameter Default IPȱConfigurationȱ ObtainȱAutomaticȱIPȱ Range ȱ ȱ YESȱ Y/Nȱ DefinesȱwhetherȱtheȱIPȱaddress,ȱwhichȱtheȱAgilityȱrefersȱto,ȱisȱstaticȱorȱdynamic.ȱ YES:ȱTheȱsystemȱrefersȱtoȱanȱIPȱaddressȱprovidedȱbyȱtheȱDHCP.ȱ NO:ȱTheȱsystemȱrefersȱtoȱaȱstaticȱIPȱAddress.ȱ PanelȱIPȱ ȱ ȱ TheȱAgilityȱIPȱaddress SubnetȱMaskȱ TheȱsubnetȱmaskȱisȱusedȱtoȱdetermineȱwhereȱtheȱnetworkȱnumberȱinȱanȱIPȱ addressȱends.ȱȱ Page 4-50 AgilityȱEngineerȱManualȱ ȱ ȱ Communication Type: IP Parameter Default Range Gatewayȱ TheȱIPȱaddressȱofȱtheȱlocalȱGateway,ȱwhichȱenablesȱcommunicationȱsettingsȱtoȱ otherȱLANȱsegments.ȱThisȱaddressȱisȱtheȱIPȱaddressȱofȱtheȱrouterȱconnectedȱtoȱ theȱsameȱLANȱsegmentȱasȱtheȱAgility.ȱ DNSȱPrimaryȱ TheȱIPȱaddressȱofȱtheȱprimaryȱDNSȱserverȱonȱtheȱnetwork.ȱȱ DNSȱSecondaryȱ TheȱIPȱaddressȱofȱtheȱsecondaryȱȱDNSȱserverȱonȱtheȱnetworkȱ EȬmailȱ ȱ ȱ AllowsȱprogrammingȱparametersȱthatȱenableȱtheȱAgilityȱtoȱsendȱEmailȱmessagesȱ followingȱFollowȱMeȱeventsȱ MailȱHostȱ ȱ ȱ ȱ ȱ TheȱIPȱaddressȱorȱtheȱHostȱnameȱofȱtheȱmailȱserver.ȱ SMTPȱPortȱ TheȱportȱaddressȱofȱtheȱSMTPȱmailȱserver.ȱDefault:ȱ00025 EȬmailȱaddressȱ ȱ ȱ AgilityȱEȬmailȱaddress.ȱDefault:ȱYourCompany.comȱ SMTPȱUserȱnameȱ Ifȱrequiredȱbyȱtheȱmailȱserver,ȱfillȱinȱtheȱAuthenticationȱUserȱnameȱ SMTPȱUserȱpasswordȱ Ifȱrequiredȱbyȱtheȱmailȱserver,ȱfillȱinȱtheȱAuthenticationȱUserȱpasswordȱ HostȱNameȱ ȱ (Upȱtoȱ32ȱcharacters)ȱ IPȱaddressȱorȱaȱtextȱnameȱusedȱtoȱidentifyȱtheȱAgilityȱoverȱtheȱnetwork.ȱ Default:ȱSecurityȱSystemȱ ȱ ȱ Page 4-51 AgilityȱEngineerȱManualȱ ȱ Communication Type: IP Parameter Default ARCȱKeepȱAliveȱ(Polling)ȱ Range 00000ȱ 0Ȭ65535ȱ Theȱtimeȱperiodȱthatȱtheȱsystemȱwillȱestablishȱautomaticȱcommunicationȱ(polling)ȱwithȱ theȱARCȱoverȱtheȱIPȱnetwork,ȱinȱorderȱtoȱcheckȱtheȱconnection.ȱ 3ȱpollingȱtimesȱcanȱbeȱdefined:ȱPrimary,ȱSecondaryȱandȱBackup.ȱForȱeachȱtimeȱperiodȱ defineȱtheȱnumberȱofȱunitsȱbetweenȱ1Ȭȱ65535.ȱEachȱunitȱrepresentsȱaȱtimeȱframeȱofȱ10ȱ seconds.ȱ Note:ȱWhenȱusingȱtheȱpollingȱfeatureȱthroughȱIP,ȱtheȱARCȱchannelȱparameterȱmustȱbeȱdefinedȱasȱIPȱonly.ȱ TheȱuseȱofȱtheseȱtimeȱperiodsȱdependsȱonȱtheȱreportingȱorderȱtoȱtheȱARCȱdefinedȱbyȱtheȱ ReportȱSplitȱARCȱUrgentȱparameterȱ(See:ȱ[4]Communicationȱ>ȱ[2]ARCȱ>ȱ[7]ReportȱSplit)ȱ Primary:ȱThisȱtimeȱperiodȱisȱusedȱwhenȱtheȱARCȱchannelȱisȱdefinedȱasȱIPȱ OnlyȱandȱtheȱReportȱSplitȱparameterȱisȱnotȱdefinedȱasȱ1stȱbackupȱ2nd.ȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ Default:ȱ00006ȱ(60ȱseconds)ȱ Secondary:ȱThisȱtimeȱperiodȱisȱusedȱwhenȱtheȱARCȱ2ȱchannelȱisȱdefinedȱasȱ IPÆIPȱȱOnlyȱandȱtheȱReportȱSplitȱparameterȱisȱdefinedȱasȱ1stȱbackupȱ2nd.ȱ Default:ȱ360ȱ(3600ȱseconds)ȱ Backup:ȱThisȱtimeȱperiodȱwillȱbeȱassignedȱtoȱtheȱbackupȱchannelȱinȱtheȱ followingȱcase:ȱ ȱȱȱARCȱ2ȱchannelȱisȱdefinedȱasȱIPÆIPȱOnlyȱ ȱȱȱReportȱSplitȱparameterȱisȱdefinedȱasȱ1stȱbackupȱ2ndȱ ȱȱȱTheȱcommunicationȱwithȱARCȱ1ȱisȱdisconnected.ȱ ȱȱȱȱȱȱȱȱDefault:ȱ00006ȱ(60ȱseconds)ȱ Controlsȱ DisableȱIPȱ ȱ ȱ ȱ ȱ YES:ȱTheȱsystemȱwillȱdisableȱtheȱIPȱmoduleȱfromȱanyȱactivity.ȱ NO:ȱTheȱIPȱmoduleȱisȱenabledȱinȱtheȱsystemȱ Page 4-52 AgilityȱEngineerȱManualȱ ȱ ȱ 4.2 Alarm Receiving Center TheȱAlarmȱReceivingȱCenterȱmenuȱcontainsȱparametersȱthatȱenableȱtheȱsystemȱtoȱestablishȱ communicationȱwithȱtheȱARCȱandȱtransmitȱdata.ȱ Communication: ARC Parameter Default ReportȱTypeȱ ȱ Range ȱ Typeȱ Definesȱtheȱcommunicationȱtypeȱthatȱtheȱsystemȱwillȱestablishȱwithȱeachȱalarmȱ receivingȱcenter.ȱTheȱsystemȱcanȱreportȱinȱ3ȱoptionalȱcommunicationȱtypes:ȱ Voiceȱȱ SMSȱ IPȱ Voiceȱ ReportsȱtoȱtheȱalarmȱreceivingȱcenterȱwillȱbeȱdoneȱthroughȱtheȱPSTNȱorȱ GSMȱnetwork.ȱReportingȱbyȱVoiceȱcanȱbeȱestablishedȱthroughȱdifferentȱ channels.ȱTheȱoptionalȱchannelsȱdependȱonȱtheȱhardwareȱinstalledȱinȱ yourȱsystem.ȱSelectȱtheȱrequiredȱchannelȱasȱfollows:ȱ x x x x PSTN/GSM:ȱȱTheȱsystemȱchecksȱforȱtheȱavailabilityȱofȱtheȱPSTNȱline.ȱDuringȱ regularȱoperationȱmodeȱallȱcallsȱandȱdataȱtransmissionȱareȱcarriedȱoutȱusingȱ theȱPSTNȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱtheȱPSTNȱline,ȱtheȱlineȱisȱroutedȱtoȱtheȱ GSMȱline.ȱ GSM/PSTN:ȱTheȱpanelȱchecksȱforȱtheȱavailabilityȱofȱtheȱGSMȱline.ȱDuringȱ regularȱoperationȱmodeȱallȱcallsȱandȱdataȱtransmissionȱareȱcarriedȱoutȱusingȱ theȱGSMȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱtheȱGSMȱline,ȱtheȱlineȱisȱroutedȱtoȱtheȱ PSTNȱline.ȱ PSTNȱOnly:ȱTheȱoutgoingȱcallsȱareȱexecutedȱthroughȱtheȱPSTNȱaudioȱ channelȱonly.ȱUseȱthisȱoptionȱforȱinstallationsȱwhereȱnoȱGSMȱlineȱisȱ available.ȱ GSMȱOnly:ȱTheȱoutgoingȱcallsȱareȱexecutedȱthroughȱtheȱGSMȱaudioȱchannelȱ only.ȱUseȱthisȱoptionȱforȱinstallationsȱwhereȱnoȱPSTNȱlineȱisȱavailable.ȱ Enterȱtheȱalarmȱreceivingȱcenterȱtelephoneȱnumberȱincludingȱareaȱcodeȱ andȱspecialȱlettersȱ(ifȱrequired).ȱIfȱcallingȱfromȱPBXȱdoȱnotȱincludeȱtheȱ numberȱforȱoutgoingȱline.ȱȱ Function Results Stopȱdialingȱandȱwaitȱforȱaȱnewȱdialȱtoneȱ Wȱ Waitȱaȱfixedȱperiodȱbeforeȱcontinuingȱ SendȱtheȱDTMFȱ¾ȱcharacterȱ ,ȱ ¾ȱ SendȱtheȱDTMFȱ#ȱcharacterȱ #ȱ Deleteȱnumbersȱfromȱtheȱcursorȱpositionȱ ȱ [¾]ȱ[0]ȱsimultaneouslyȱȱ Page 4-53 AgilityȱEngineerȱManualȱ ȱ Communication: ARC Parameter Default Range SMSȱ EventsȱareȱsentȱtoȱtheȱalarmȱreceivingȱcenterȱusingȱencryptedȱSMSȱ messagesȱ(128ȱBITȱAESȱencryption).ȱEachȱeventȱmessageȱcontainsȱ informationȱincludingȱtheȱaccountȱnumber,ȱreportȱcode,ȱcommunicationȱ format,ȱtimeȱofȱeventȱandȱmore.ȱTheȱeventȱmessagesȱareȱreceivedȱbyȱ RISCOȱGroupȇsȱIP/GSMȱReceiverȱSoftwareȱlocatedȱatȱtheȱARCȱsite.ȱTheȱ IP/GSMȱReceiverȱtranslatesȱtheȱSMSȱmessagesȱtoȱstandardȱprotocolsȱ usedȱbyȱtheȱalarmȱreceivingȱcenterȱapplicationsȱ(Forȱexample;ȱContactȱ ID).ThisȱchannelȱrequiresȱthatȱRISCOȱGroup’sȱIP/GSMȱreceiverȱhasȱtoȱbeȱ usedȱatȱtheȱARCȱside.ȱȱ EnterȱtheȱrelevantȱphoneȱnumbersȱforȱtheȱARCȱthatȱwillȱreceiveȱreportsȱ fromȱtheȱsystem.ȱ(SeeȱexplanationȱinȱVoiceȱtypeȱonȱpageȱ4Ȭ53)ȱ IPȱ EncryptedȱeventsȱareȱsentȱtoȱtheȱalarmȱreceivingȱcenterȱoverȱtheȱIPȱorȱ GPRSȱnetworkȱusingȱTCP/IPȱprotocol.ȱ128ȱBITȱAESȱencryptionȱisȱused.ȱ RISCOȱGroupȇsȱIP/GSMȱReceiverȱSoftwareȱlocatedȱatȱtheȱARCȱsiteȱ receivesȱtheȱmessagesȱandȱtranslatesȱthemȱtoȱstandardȱprotocolsȱusedȱbyȱ theȱalarmȱreceivingȱcenterȱapplicationsȱ(Forȱexample;ȱContactȱID).ȱȱ Note:ȱToȱenableȱGPRSȱcommunicationȱtheȱSIMȱcardȱhasȱtoȱsupportȱGPRSȱchannelȱ ReportingȱbyȱIPȱcanȱbeȱestablishedȱthroughȱdifferentȱchannels.ȱTheȱ optionalȱchannelsȱdependȱonȱtheȱhardwareȱinstalledȱinȱyourȱsystem.ȱ SelectȱtheȱrequiredȱchannelȱviaȱtheȱConfigurationȱSoftwareȱasȱfollows:ȱ x x x x IP/GPRS:ȱȱTheȱpanelȱchecksȱforȱtheȱavailabilityȱofȱtheȱIPȱnetwork.ȱDuringȱ regularȱoperationȱmodeȱallȱcallsȱandȱdataȱtransmissionȱareȱcarriedȱoutȱusingȱ theȱIPȱnetworkȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱtheȱIPȱnetwork,ȱtheȱreportȱisȱroutedȱ toȱtheȱGPRSȱnetwork.ȱ GPRS/IP:ȱȱTheȱpanelȱchecksȱforȱtheȱavailabilityȱofȱtheȱGPRSȱnetwork.ȱDuringȱ regularȱoperationȱmodeȱallȱcallsȱandȱdataȱtransmissionȱareȱcarriedȱoutȱusingȱ theȱGPRS.ȱInȱtheȱcaseȱofȱfaultȱtheȱreportȱisȱroutedȱtoȱtheȱIPȱnetwork.ȱ IPȱOnly:ȱTheȱreportȱisȱexecutedȱthroughȱtheȱIPȱnetworkȱonly.ȱ GPRSȱOnly:ȱTheȱreportȱisȱexecutedȱthroughȱtheȱGPRSȱnetwork.ȱ EnterȱtheȱrelevantȱIPȱandȱPortȱnumbersȱforȱtheȱARCȱthatȱwillȱreceiveȱ reportsȱfromȱtheȱsystem.ȱ(SeeȱIPȱandȱPort)ȱ Page 4-54 AgilityȱEngineerȱManualȱ ȱ ȱ Communication: ARC Parameter Default Range Accountsȱ AccountȱNumberȱ Theȱnumberȱthatȱrecognizesȱtheȱcustomerȱatȱtheȱalarmȱreceivingȱcenter.ȱYouȱcanȱ defineȱanȱaccountȱnumberȱforȱeachȱalarmȱreceivingȱcenter.ȱTheseȱaccountȱ numbersȱareȱtheȱ6Ȭdigitȱnumbersȱassignedȱbyȱtheȱcentralȱstation.ȱ NotesȱforȱAccountȱNumberȱinȱContactȱIDȱCommunicationȱFormat:ȱȱ 1. Theȱaccountȱnumberȱwillȱalwaysȱbeȱreportedȱasȱ4ȱdigits,ȱȱforȱexample:ȱAȱnumberȱ definedȱasȱ000012ȱwillȱbeȱreportedȱasȱ0012ȱ 2. Ifȱmoreȱthanȱ4ȱdigitsȱwereȱdefined,ȱtheȱsystemȱalwaysȱsendsȱtheȱlastȱ4ȱdigitsȱofȱtheȱ accountȱnumber,ȱforȱexample:ȱAccountȱnumberȱthatȱwasȱdefinedȱasȱ123456ȱwillȱbeȱsentȱ asȱ3456.ȱȱ 3. InȱContactȱIDȱyouȱcanȱplaceȱdigitsȱandȱlettersȱAȬF.ȱTheȱAȱcharacterȱisȱalwaysȱsentȱasȱ0ȱ forȱexample:ȱAccountȱnumberȱthatȱwasȱdefinedȱasȱ00C2ABȱwillȱbeȱsentȱasȱC20B.ȱ NotesȱforȱAccountȱNumberȱinȱSIAȱCommunicationȱFormat:ȱȱ 1. AccountȱnumberȱforȱSIAȱshouldȱbeȱdefinedȱasȱaȱdecimalȱnumberȱ(Onlyȱdigitsȱ0..9)ȱ 2. Accountȱnumberȱcanȱbeȱreportedȱasȱ1ȱtoȱ6ȱdigits.ȱToȱsendȱanȱaccountȱnumberȱwithȱlessȱ thanȱ6ȱdigitsȱuseȱtheȱ“0”ȱdigit,ȱforȱexample:ȱForȱaccountȱnumberȱ1234ȱenterȱ001234.ȱInȱ thisȱcaseȱtheȱsystemȱwillȱnotȱsendȱtheȱ“0”ȱdigitȱtoȱtheȱARC.ȱ 3.ȱȱȱȱȱȱInȱorderȱtoȱsendȱtheȱ“0”ȱdigitȱinȱSIAȱformat,ȱlocatedȱatȱtheȱleftȱsideȱofȱtheȱnumber,ȱuseȱȱ ȱȱȱȱȱȱȱȱȱtheȱ“A”ȱdigitȱinsteadȱofȱtheȱ“0”ȱdigit.ȱForȱexample,ȱforȱaccountȱnumberȱ0407ȱenterȱȱ ȱȱȱȱȱȱȱȱȱ00A407,ȱforȱaȱ6ȱdigitȱaccountȱnumberȱsuchȱasȱ001207ȱenterȱAA1207.ȱ CommunicationsȱFormatȱ EnablesȱtheȱsystemȱtoȱcontactȱtheȱARCȱinȱorderȱtoȱobtainȱdetailsȱofȱtheȱ communicationȱprotocolȱusedȱbyȱtheȱdigitalȱreceiverȱforȱeachȱaccount.ȱ Theȱcodesȱareȱautomaticallyȱuploadedȱwhenȱtheȱcommunicationȱformatȱhasȱbeenȱ selected:ȱ ContactȱID:ȱTheȱsystemȱallocatesȱReportȱCodesȱsupportingȱADEMCOȱContactȱ (Point)ȱIDȱ SIA:ȱTheȱsystemȱallocatesȱReportȱCodesȱsupportingȱtheȱSIAȱ(SecurityȱIndustryȱ Association)ȱformatȱȱ Note:ȱSeeȱAppendixȱAȱforȱtheȱreportȱcodesȱlist.ȱ Controlsȱ AllowsȱtoȱprogramȱcontrolȱrelatedȱtoȱoperationȱwithȱtheȱARC.ȱ Page 4-55 AgilityȱEngineerȱManualȱ ȱ Communication: ARC Parameter Default Handshakeȱ Range NOȱ ȱ YES:ȱAllȱLEDsȱonȱtheȱAgilityȱmainȱunitȱlightȱforȱoneȱsecondȱwhenȱtheȱhandshakeȱ signalȱisȱreceivedȱfromȱtheȱCentralȱStationȇsȱreceiver.ȱ NO:ȱNoȱindicationȱforȱestablishingȱcommunicationȱwithȱtheȱCentralȱStationȇsȱ receiver.ȱ KissȬOffȱY/Nȱ NOȱ ȱ YES:ȱAllȱLEDsȱonȱtheȱAgilityȱmainȱunitȱlightȱforȱoneȱsecondȱandȱanȱaudibleȱsoundȱ isȱemittedȱwhenȱtheȱkissȬoffȱsignalȱisȱreceivedȱfromȱtheȱCentralȱStationȇsȱreceiver.ȱ NO:ȱNoȱindicationȱforȱestablishingȱcommunicationȱwithȱtheȱCentralȱStationȇsȱ receiver.ȱ Parametersȱ AllowsȱtoȱprogramȱparametersȱrelatedȱtoȱoperationȱwithȱtheȱARC.ȱ ARCȱRetriesȱ 08ȱ 01Ȭ15ȱ TheȱnumberȱofȱtimesȱtheȱsystemȱredialsȱtheȱARCȱafterȱfailingȱtoȱestablishȱ communication.ȱ AlarmȱRestoreȱ CTOȱ ȱ SpecifiesȱunderȱwhatȱconditionsȱanȱAlarmȱRestoralȱisȱreported.ȱThisȱoptionȱ informsȱtheȱARCȱofȱaȱchangeȱinȱtheȱspecifiedȱcondition(s)ȱduringȱanȱalarmȱrestore.ȱ TheseȱreportsȱneedȱaȱvalidȱReportȱCode.ȱ OnȱConfirmationȱTimeȱOutȱ(CTO)ȱȬȱReportsȱtheȱrestoralȱofȱaȱconfirmedȱzoneȱatȱ theȱendȱofȱtheȱConfirmationȱTimeȱWindowȱ(Seeȱpageȱ4Ȭ57)ȱ.ȱ FollowȱZoneȱȬȱReportsȱtheȱrestoralȱwhenȱtheȱzoneȱinȱwhichȱtheȱalarmȱoccursȱ returnsȱtoȱitsȱnonȬviolatedȱ(secured)ȱstate.ȱ AtȱUnsetȱȬȱReportsȱtheȱrestoralȱwhenȱtheȱsystemȱ(orȱtheȱpartitionȱinȱwhichȱtheȱ alarmȱoccurs)ȱisȱunset,ȱevenȱifȱtheȱsounderȱhasȱalreadyȱtimedȱout.ȱ ARCȱTimersȱ ȱ ȱ AllowsȱtoȱprogramȱtimersȱrelatedȱtoȱoperationȱwithȱtheȱARC.ȱ PeriodicȱTestȱ ȱ ȱ TheȱPeriodicȱTestȱenablesȱyouȱtoȱsetȱtheȱtimeȱperiodȱthatȱtheȱsystemȱwillȱ automaticallyȱestablishȱcommunicationȱtoȱtheȱARCȱinȱorderȱtoȱcheckȱtheȱ connection.ȱTheȱperiodicȱtestȱinvolvesȱsendingȱtheȱaccountȱnumberȱandȱaȱvalidȱ testȱreportȱcodeȱ(ContactȱIDȱ602,ȱSIAȱTX).ȱȱSetȱtheȱtestȱtimeȱandȱdailyȱintervalȱforȱ PeriodicȱTestȱReporting.ȱȱ Page 4-56 AgilityȱEngineerȱManualȱ ȱ ȱ Communication: ARC Parameter Default AbortȱAlarmȱȱ 15ȱsecȱ Range 0Ȭ255ȱsecȱ DefinesȱtheȱtimeȱdelayȱbeforeȱreportingȱanȱalarmȱtoȱtheȱARC.ȱIfȱtheȱalarmȱsystemȱ isȱUnsetȱwithinȱtheȱAbortȱWindow,ȱnoȱalarmȱtransmissionȱshallȱbeȱsentȱtoȱtheȱ ARC.ȱ CancelȱDelayȱȱ 5ȱminȱ 0Ȭ255ȱminȱ Ifȱanȱalarmȱisȱsentȱinȱerror,ȱitȱisȱpossibleȱforȱtheȱARCȱtoȱreceiveȱaȱCancelȱAlarmȱ Code,ȱsentȱsubsequentlyȱtoȱtheȱinitialȱAlarmȱCode.ȱThisȱhappensȱifȱaȱvalidȱUserȱ CodeȱisȱenteredȱtoȱresetȱtheȱalarmȱinȱtheȱCancelȱDelayȱtimeȱwindowȱthatȱstartsȱ afterȱtheȱdefinedȱAbortȱAlarmȱtimeȱisȱover.ȱȱ Note:ȱCancelȱAlarmȱreportȱcodeȱshouldȱbeȱdefined.ȱ ListenȱInȱ 120ȱ 1Ȭ240ȱsecondsȱ TheȱtimeȱdurationȱforȱtheȱalarmȱreceivingȱcenterȱtoȱListenȱinȱandȱperformȱvoiceȱ alarmȱverification.ȱAfterȱthisȱperiodȱtheȱsystemȱhangsȱupȱtheȱline.ȱȱ TheȱARCȱcanȱexpandȱtheȱlistenȱinȱtimeȱduringȱtheȱconversationȱbyȱpressingȱtheȱ digitȱȈ1Ȉȱonȱtheȱtelephone.ȱInȱthisȱcase,ȱtheȱListenȱInȱtimeȱwillȱresetȱandȱstartȱoverȱ again.ȱ Confirmationȱ ȱ ȱ TheȱconfirmationȱtimesȱrelateȱtoȱtheȱZoneȱSequentialȱConfirmation.ȱ ConfirmȱStartȱ(Confirmȱdelayȱtime)ȱ 0ȱ 0Ȭ120ȱminȱ Specifiesȱthatȱtheȱsystemȱcannotȱstartȱaȱsequentialȱconfirmationȱprocessȱ untilȱtheȱtimerȱhasȱexpired.ȱThisȱtimeȱstartsȱwhenȱtheȱsystemȱhasȱsetȱandȱ willȱpreventȱconfirmedȱalarmsȱbeingȱgeneratedȱinȱsituationsȱwhenȱaȱ personȱhasȱbeenȱaccidentallyȱlockedȱinȱtheȱbuilding.ȱ ConfirmȱTimeȱWindowȱ 030ȱ 30Ȭ60ȱminȱ Specifiesȱaȱtimeȱperiodȱthatȱstartsȱwhenȱanȱalarmȱisȱtriggeredȱforȱtheȱfirstȱ time.ȱIfȱaȱsecondȱalarmȱisȱtriggeredȱbeforeȱtheȱendȱofȱtheȱconfirmationȱ timeȱwindow,ȱtheȱsystemȱwillȱsendȱaȱconfirmedȱalarmȱtoȱtheȱalarmȱ receivingȱcenter.ȱ NoȱȱSetȱ 0ȱ 0Ȭ12ȱweeksȱ Aȱ Noȱ Setȱ codeȱ willȱ beȱ sentȱ toȱ theȱ ARCȱ ifȱ noȱ settingȱ orȱ unsettingȱ hasȱ beenȱ establishedȱduringȱtheȱtimeȱdefinedȱ(1Ȭ12ȱweeks).ȱ (0=notȱactivated)ȱ ReportȱSplitȱȱ ȱ ȱ TheȱReportȱSplitȱmenuȱcontainsȱparametersȱthatȱenableȱtheȱroutingȱofȱspecifiedȱeventsȱtoȱ upȱtoȱthreeȱARCȱReceivers.ȱ(SeeȱAppendixȱAȱReportsȱCodes)ȱ Page 4-57 AgilityȱEngineerȱManualȱ ȱ Communication: ARC Parameter Default ARCȱSet/Unsetȱ ȱ Range ȱ ReportsȱSetting/Unsettingȱ(meaningȱClosings/Openings)ȱeventsȱtoȱtheȱARCȱ Doȱnotȱcallȱ(noȱreport)ȱ Callȱ1st:ȱReportsȱOpeningsȱandȱClosingsȱtoȱARCȱ1ȱ Callȱ2nd:ȱReportsȱOpeningsȱandȱClosingsȱtoȱARCȱ2ȱ Callȱ3rd:ȱReportsȱOpeningsȱandȱClosingsȱtoȱARCȱ3ȱ Callȱall:ȱReportsȱOpeningsȱandȱClosingsȱtoȱallȱdefinedȱARC.ȱ 1stȱBackupȱ2nd:ȱReportsȱOpeningsȱandȱClosingsȱtoȱARCȱ1.ȱIfȱcommunicationȱisȱ notȱestablished,ȱcallsȱARCȱ2.ȱ ARCȱUrgentȱ ȱ ȱ Reportsȱurgentȱ(alarm)ȱeventsȱtoȱtheȱARCȱ Doȱnotȱcallȱ(noȱreport)ȱ Callȱ1st:ȱReportsȱurgentȱeventsȱtoȱARCȱ1ȱ Callȱ2nd:ȱReportsȱurgentȱeventsȱtoȱARCȱ2ȱ Callȱ3rd:ȱReportsȱurgentȱeventsȱtoȱARCȱ3ȱ Callȱall:ȱReportsȱurgentȱeventsȱtoȱallȱdefinedȱARC.ȱ 1stȱBackupȱ2nd:ȱReportsȱurgentȱeventsȱtoȱARCȱ1.ȱIfȱcommunicationȱisȱnotȱ established,ȱcallsȱARCȱ2ȱ ARCȱNonȱUrgentȱ ȱ ȱ ReportsȱnonȬurgentȱeventsȱ(faultsȱandȱtestȱreports)ȱtoȱtheȱARCȱ Doȱnotȱcallȱ(noȱreport)ȱ Callȱ1st:ȱReportsȱnonȬurgentȱeventsȱtoȱARCȱ1ȱ Callȱ2nd:ȱReportsȱnonȬurgentȱeventsȱtoȱARCȱ2ȱ Callȱ3rd:ȱReportsȱnonȬurgentȱeventsȱtoȱARCȱ3ȱ Callȱall:ȱReportsȱnonȬurgentȱeventsȱtoȱallȱdefinedȱARC.ȱ 1stȱBackupȱ2nd:ȱReportsȱnonȬurgentȱeventsȱtoȱARCȱ1.ȱIfȱcommunicationȱisȱnotȱ established,ȱcallsȱARCȱ2ȱ Page 4-58 AgilityȱEngineerȱManualȱ ȱ ȱ Communication: ARC Parameter Default Range ReportȱCodesȱȱ ȱ ȱ Enablesȱyouȱtoȱviewȱorȱprogramȱtheȱcodesȱtransmittedȱbyȱtheȱsystemȱtoȱreportȱeventsȱ(forȱ example,ȱalarms,ȱfaults,ȱrestores,ȱsupervisoryȱtests,ȱandȱsoȱon)ȱtoȱtheȱalarmȱreceivingȱ center.ȱTheȱcodesȱspecifiedȱforȱeachȱtypeȱofȱeventȱtransmissionȱareȱaȱfunctionȱofȱtheȱCentralȱ Stationȇsȱownȱpolicies.ȱBeforeȱprogrammingȱanyȱcodes,ȱitȱisȱimportantȱtoȱcheckȱtheȱCentralȱ Stationȱprotocols.ȱReportingȱcodesȱareȱassignedȱbyȱdefault,ȱaccordingȱtoȱtheȱselectedȱ communicationȱformatȱSIAȱorȱContactȱIDȱ Assignsȱaȱspecifiedȱreportȱcodeȱforȱeachȱevent,ȱbasedȱonȱtheȱreportingȱformatȱtoȱtheȱalarmȱ receivingȱcenter.ȱAnȱeventȱthatȱisȱnotȱassignedȱwithȱaȱreportȱcodeȱwillȱnotȱbeȱreportedȱtoȱ theȱalarmȱreceivingȱcenter.ȱForȱlistȱofȱreportȱeventsȱreferȱtoȱAppendixȱA.ȱ 4.3 Configuration Software TheȱConfigurationȱSoftwareȱmenuȱcontainsȱparametersȱthatȱenableȱtheȱconfigurationȱ softwareȱtoȱestablishȱconnectionȱwithȱtheȱsystem.ȱ Communication: Configuration software Parameter Default Securityȱ Range ȱ ȱ Enablesȱyouȱtoȱsetȱparametersȱforȱremoteȱcommunicationȱbetweenȱtheȱtechnicianȱandȱtheȱ systemȱusingȱtheȱConfigurationȱsoftwareȱ AccessȱCodeȱ 5678ȱ ȱ EnablesȱyouȱtoȱdefineȱanȱAccessȱCodeȱthatȱisȱstoredȱinȱtheȱsystem.ȱ RISCOȱGroupȱrecommendsȱusingȱaȱdifferentȱ4ȬdigitȱAccessȱCodeȱforȱeachȱ installation.ȱ Inȱorderȱtoȱenableȱcommunicationȱbetweenȱtheȱalarmȱcompanyȱandȱtheȱsystemȱ theȱsameȱAccessȱCodeȱmustȱsubsequentlyȱbeȱenteredȱintoȱtheȱcorrespondingȱ accountȱprofileȱcreatedȱforȱtheȱinstallationȱinȱtheȱconfigurationȱsoftwareȱ Forȱsuccessfulȱcommunication,ȱtheȱAccessȱCodeȱalongȱwithȱtheȱIDȱcodeȱmustȱ matchȱbetweenȱtheȱconfigurationȱsoftwareȱandȱtheȱsystem.ȱ RemoteȱIDȱȱȱ 0001ȱ DefinesȱanȱIDȱCodeȱthatȱservesȱasȱanȱextensionȱofȱtheȱAccessȱCode.ȱ Inȱorderȱtoȱenableȱcommunicationȱbetweenȱtheȱalarmȱcompanyȱandȱtheȱ Installation,ȱtheȱsameȱRemoteȱIDȱcodeȱmustȱbeȱenteredȱintoȱtheȱaccountȱprofileȱ inȱtheȱconfigurationȱsoftware.ȱ Forȱsuccessfulȱcommunication,ȱtheȱIDȱCodeȱalongȱwithȱtheȱAccessȱCodeȱmustȱ matchȱbetweenȱtheȱUpload/DownloadȱsoftwareȱandȱtheȱMainȱPanel.ȱ DealersȱoftenȱuseȱtheȱcustomerȇsȱARCȱAccountȱNumberȱforȱtheȱȱ IDȱCode,ȱbutȱyouȱcanȱuseȱanyȱ4Ȭdigitȱcodeȱuniqueȱtoȱtheȱinstallationȱ Page 4-59 AgilityȱEngineerȱManualȱ ȱ Communication: Configuration software Parameter Default ARCȱLockȱ Range 000000ȱ ȱ ARCȱLockȱisȱaȱsecurityȱfunctionȱusedȱinȱconjunctionȱwithȱtheȱconfigurationȱ software.ȱItȱprovidesȱgreaterȱproprietaryȱsecurityȱwhenȱviewingȱARCȱ parameters.ȱ Theȱsameȱ6Ȭdigitȱcode,ȱwhichȱwillȱbeȱstoredȱinȱtheȱpanel,ȱmustȱbeȱenteredȱintoȱ theȱcorrespondingȱaccountȱprofileȱcreatedȱforȱtheȱinstallationȱinȱtheȱ Configurationȱsoftware.ȱȱ IfȱthereȱisȱnoȱmatchȱbetweenȱtheȱARCȱLockȱCodeȱdefinedȱinȱtheȱMainȱPanelȱandȱ theȱARCȱLockȱCodeȱdefinedȱinȱtheȱConfigurationȱsoftware,ȱtheȱEngineerȱwillȱnotȱ haveȱpermissionȱtoȱchangeȱtheȱfollowingȱARCȱparametersȱfromȱtheȱ Configurationȱsoftware:ȱȱ ARCȱLock,ȱEngineerȱCode,ȱARCȱIPȱPort,ȱARCȱIPȱAddress,ȱARCȱPhone,ȱDefaultȱ Enable,ȱARCȱAccount,ȱARCȱFormat,ȱARCȱChannel,ȱARCȱBackup,ȱARCȱEnable,ȱ RemoteȱID,ȱAccessȱCode.ȱ CallȱBackȱ CallȱBackȱȱEnableȱ ȱ ȱ YESȱ ȱ TheȱcallȱbackȱfeatureȱrequiresȱtheȱsystemȱtoȱcallȱbackȱtoȱaȱpreȬprogrammedȱ telephoneȱnumberȱtoȱwhichȱtheȱalarmȱcompanyȇsȱconfigurationȱsoftwareȱ computerȱisȱinstalled.ȱThisȱprovidesȱmoreȱsecurityȱforȱremoteȱoperationsȱusingȱ theȱconfigurationȱsoftware.ȱȱ YES:ȱCallȱbackȱisȱenabledȱ NO:ȱCallȱbackȱisȱdisabledȱ CallȱBackȱPhonesȱȱ ȱ ȱ Defineȱ3ȱnumbersȱthatȱtheȱpanelȱcanȱcallȱtoȱperformȱConfigurationȱSoftwareȱ communication.ȱIfȱnoȱnumbersȱhaveȱbeenȱdefined,ȱaȱcallȱbackȱcanȱbeȱperformedȱ toȱanyȱphone.ȱTheȱengineerȱwillȱenterȱaȱphoneȱnumberȱwhenȱestablishingȱ communicationȱtoȱtheȱpanel.ȱIfȱatȱleastȱoneȱnumberȱhasȱbeenȱdefined,ȱitȱwillȱbeȱ theȱonlyȱnumberȱthatȱtheȱcallȱbackȱcanȱbeȱestablishedȱtoo.ȱȱ WhenȱtheȱConfigurationȱSoftwareȱestablishesȱcommunicationȱtoȱtheȱpanel,ȱitȱ sendsȱtheȱpanelȱitsȱcallingȱphoneȱnumber.ȱ(Thisȱnumberȱneedsȱtoȱbeȱdefinedȱasȱ MyȱNumberȱunderȱtheȱGSMȱandȱPSTNȱCommunicationȱmenuȱinȱtheȱ ConfigurationȱSoftware.)ȱ Ifȱtheȱpanelȱidentifiesȱoneȱofȱtheȱnumbersȱasȱoneȱofȱtheȱnumbersȱpredefinedȱinȱ theȱpanel,ȱtheȱcallȱwillȱhangȱupȱandȱtheȱpanelȱwillȱcallȱbackȱtoȱthatȱsameȱnumber.ȱȱ Page 4-60 AgilityȱEngineerȱManualȱ ȱ ȱ Communication: Configuration software Parameter Default ConfigurationȱSoftwareȱPortȱ(IPȱGateway)ȱ Range 00000ȱ ȱ TheȱIPȱandȱportȱaddressȱofȱtheȱconfigurationȇsȱsoftwareȱPC.ȱIfȱyouȱhaveȱaȱrouterȱ connectedȱtoȱtheȱPCȱofȱtheȱconfigurationȱsoftwareȱthenȱyouȱshouldȱenterȱtheȱIPȱofȱtheȱ router.ȱ Thisȱdefinitionȱwillȱbeȱusedȱwhenȱthereȱisȱaȱrequestȱtoȱcreateȱaȱremoteȱconnectionȱfromȱ theȱpanelȱtoȱtheȱconfigurationȱsoftware.ȱTheȱconnectionȱcanȱbeȱdoneȱoverȱIPȱorȱGPRS.ȱ Note:ȱInȱtheȱconfigurationȱsoftware,ȱunderȱCommunicationÆȱConfigurationÆGPRSȱyouȱshouldȱenterȱtheȱ IPȱaddressȱofȱtheȱPCȱthatȱtheȱsoftwareȱisȱinstalledȱin.ȱ 4.4 Follow-Me Inȱadditionȱtoȱreportingȱtoȱtheȱalarmȱreceivingȱcenter,ȱtheȱAgilityȱhasȱaȱFollowȬMeȱfeatureȱ whichȱenablesȱreportingȱaȱsystemȱeventsȱtoȱaȱpredefinedȱfollowȱmeȱdestinationsȱusingȱaȱ voiceȱmessage,ȱSMSȱmessageȱorȱEmail.ȱȱUpȱtoȱ16ȱFollowȱMeȱdestinationsȱcanȱbeȱdefinedȱinȱ theȱsystem.ȱ Parametersȱ Communication: Follow-Me Parameter Default Labelȱ(viaȱtheȱConfigurationȱSoftware)ȱ Range ȱ ȱ ȱ ȱ Aȱlabelȱidentifyingȱtheȱfollowȱmeȱdestinationȱ Typeȱ Definesȱtheȱtypeȱofȱreportingȱeventsȱtoȱaȱfollowȱmeȱdestination:ȱ Voice:ȱReportȱtoȱfollowȱmeȱwillȱbeȱdoneȱbyȱvoiceȱmessageȱthoroughȱtheȱ PSTNȱorȱGSMȱnetwork.ȱ(SeeȱChannelÆȱForȱVoiceȱMessagingȱbelow).ȱTypeȱinȱ theȱtelephoneȱnumberȱincludingȱareaȱcodeȱorȱspecialȱlettersȱforȱFollowȱMeȱ definedȱasȱSMSȱorȱVoice.ȱ SMS:ȱReportȱtoȱfollowȱmeȱwillȱbeȱdoneȱbyȱSMS.ȱEachȱeventȱmessageȱcontainsȱ informationȱincludingȱtheȱsystemȱlabel.ȱEventȱtypeȱandȱtime.ȱTypeȱinȱtheȱ telephoneȱnumberȱincludingȱareaȱcodeȱorȱspecialȱlettersȱforȱFollowȱMeȱ definedȱasȱSMSȱorȱVoice.ȱ EȬmail:ȱReportȱtoȱfollowȱmeȱwillȱbeȱdoneȱbyȱeȬmailȱthoroughȱIPȱorȱGPRS.ȱ EachȱeȬmailȱcontainsȱinformationȱincludingȱtheȱsystemȱlabel.ȱEventȱtypeȱandȱ time.ȱ(SeeȱChannelÆȱForȱEȬmailȱreportȱbelow)TypeȱinȱtheȱeȬmailȱaddressȱforȱ followȱmeȱdestinationȱdefinedȱasȱeȬmailȱtype.ȱ Page 4-61 AgilityȱEngineerȱManualȱ ȱ Communication: Follow-Me Parameter Default Channelȱ ȱ Range ȱ ReportingȱeventsȱbyȱVoiceȱorȱEmailȱcanȱbeȱestablishedȱthroughȱdifferentȱchannels.ȱTheȱ optionalȱchannelsȱdependȱonȱtheȱhardwareȱinstalledȱinȱtheȱsystem.ȱSelectȱtheȱrequiredȱ channelȱasȱfollows:ȱ ForȱVoiceȱMessaging:ȱ PSTN/GSM:ȱȱTheȱsystemȱchecksȱforȱtheȱavailabilityȱofȱtheȱPSTNȱline.ȱDuringȱregularȱ operationȱmodeȱvoiceȱmessagingȱisȱcarriedȱoutȱusingȱtheȱPSTNȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱ theȱPSTNȱline,ȱtheȱlineȱisȱroutedȱtoȱtheȱGSMȱline.ȱ GSM/PSTN:ȱTheȱpanelȱchecksȱforȱtheȱavailabilityȱofȱtheȱGSMȱline.ȱDuringȱregularȱ operationȱmodeȱvoiceȱmessagingȱisȱcarriedȱoutȱusingȱtheȱGSMȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱ theȱGSMȱline,ȱtheȱlineȱisȱroutedȱtoȱtheȱPSTNȱline.ȱ PSTNȱOnly:ȱTheȱoutgoingȱcallsȱareȱexecutedȱthroughȱtheȱPSTNȱaudioȱchannelȱonly.ȱUseȱ thisȱoptionȱforȱinstallationsȱwhereȱnoȱGSMȱlineȱisȱavailable.ȱ GSMȱOnly:ȱTheȱoutgoingȱcallsȱareȱexecutedȱthroughȱtheȱGSMȱaudioȱchannelȱonly.ȱUseȱthisȱ optionȱforȱinstallationsȱwhereȱnoȱPSTNȱlineȱisȱavailable.ȱ ForȱEȬmailȱreport:ȱ IP/GPRS:ȱȱTheȱsystemȱchecksȱforȱtheȱavailabilityȱofȱtheȱIPȱnetwork.ȱDuringȱregularȱ operationȱemailsȱwillȱbeȱsentȱusingȱtheȱIPȱnetworkȱline.ȱInȱtheȱcaseȱofȱfaultȱinȱtheȱIPȱ network,ȱtheȱemailȱisȱroutedȱtoȱtheȱGPRSȱnetwork.ȱ GPRS/IP:ȱȱTheȱsystemȱchecksȱforȱtheȱavailabilityȱofȱtheȱGPRSȱnetwork.ȱDuringȱregularȱ operationȱmodeȱemailsȱwillȱbeȱsentȱusingȱtheȱGPRS.ȱInȱtheȱcaseȱofȱfaultȱtheȱemailȱisȱroutedȱ toȱtheȱIPȱnetwork.ȱ IPȱOnly:ȱTheȱreportȱisȱexecutedȱthroughȱtheȱIPȱnetworkȱonly.ȱ GPRSȱOnly:ȱTheȱreportȱisȱexecutedȱthroughȱtheȱGPRSȱnetworkȱ Eventsȱ EachȱFollowȱMeȱdestinationȱcanȱbeȱassignedȱwithȱitsȱownȱsetȱofȱevents.ȱChooseȱtheȱeventsȱ thatȱwillȱbeȱreportedȱtoȱeachȱFollowȱMeȱ Eventȱ Descriptionȱ Defaultȱ Alarmsȱ Intruderȱ Intruderȱalarmȱinȱtheȱsystemȱ Yesȱ Fireȱ Fireȱalarmȱinȱtheȱsystemȱȱ Yesȱ Emergencyȱ Emergencyȱalarmȱinȱtheȱsystemȱȱ Yesȱ Panicȱ(S.O.S)ȱ Aȱpanicȱalarmȱinȱtheȱsystemȱ Yesȱ Tamperȱ Anyȱtamperȱalarmȱinȱtheȱsystemȱ Noȱ DuressȱAlarmȱ Duressȱalarmȱinȱtheȱsystemȱfromȱuserȱxxȱ Yesȱ NoȱMovementȱ Noȱmovementȱreportȱindicationȱ Noȱ Page 4-62 AgilityȱEngineerȱManualȱ ȱ ȱ Communication: Follow-Me Parameter Default Range Set/Unsetȱ Setȱ Settingȱoperationȱhasȱbeenȱperformedȱinȱtheȱsystemȱ Noȱ Unsetȱ Unsettingȱoperationȱhasȱbeenȱperformedȱinȱtheȱsystemȱ Noȱ ParentȱControlȱ Systemȱset/unsetȱbyȱuser/remoteȱcontrolȱdefinedȱwithȱ theȱParentȱcontrolȱfeatureȱ Noȱ Afterȱ5ȱunsuccessfulȱattemptsȱofȱenteringȱanȱincorrectȱ code.ȱȱ Noȱ Faultsȱ FalseȱCodeȱ MainȱLowȱBatteryȱ LowȱbatteryȱindicationȱfromȱtheȱAgilityȱmainȱpanelȱ (belowȱ6V)ȱ Noȱ WirelessȱLowȱ Batteryȱ Lowȱbatteryȱindicationȱfromȱanyȱwirelessȱdeviceȱinȱtheȱ systemȱ Noȱ WLȱJammingȱ Jammingȱindicationȱinȱtheȱsystemȱ Noȱ WLȱLostȱ Wirelessȱdeviceȱlost.ȱWhenȱnoȱsupervisionȱsignalȱisȱ receivedȱfromȱaȱwirelessȱdeviceȱ Noȱ ACȱOffȱ InterruptionȱinȱtheȱsourceȱofȱtheȱmainȱACȱpower.ȱThisȱ activationȱwillȱfollowȱtheȱdelayȱtimeȱpredefinedȱinȱtheȱ ACȱLossȱDelayȱtimerȱ Noȱ PSTNȱFaultȱ PSTNȱlostȱevent.ȱIfȱPSTNȱLossȱDelayȱtimeȱperiodȱisȱ defined,ȱtheȱmessageȱwillȱbeȱsentȱafterȱtheȱdelayȱtimeȱ Noȱ IPȱNetworkȱ CommunicationȱfaultȱwithȱtheȱIPȱnetwork.ȱ Noȱ GSMȱFaultȱ GeneralȱGSMȱfaultȱ(SIMȱcardȱfault,ȱNetworkȱ availability,ȱNetworkȱQuality,ȱPINȱcodeȱerror,ȱModuleȱ communication,ȱGPRSȱpassword,ȱGPRSȱIPȱfault,ȱGPRSȱ Connection,ȱPUKȱcodeȱfaultȱ Noȱ SIMȱFaultȱ AnyȱfaultȱwithȱtheȱSIMȱcardȱ Noȱ SIMȱExpireȱ ReportȱtoȱFollowȱMeȱwillȱbeȱestablishedȱ30ȱdaysȱbeforeȱ theȱSIMȱExpirationȱTimeȱdefinedȱforȱaȱprepaidȱSIMȱcard. Noȱ SIMȱCreditȱ AnȱautomaticȱSMSȱcreditȱmessageȱ(orȱanyȱotherȱ message)ȱreceivedȱfromȱtheȱprovider’sȱnumberȱ predefinedȱinȱSMSȱReceiveȱPhoneȱwillȱbeȱtransferredȱtoȱ theȱFollowȱMeȱnumberȱ Noȱ GSMȱȱ Page 4-63 AgilityȱEngineerȱManualȱ ȱ Communication: Follow-Me Parameter Default Range Environmentalȱȱ GasȱAlertȱ Gasȱ(naturalȱgas)ȱalertȱfromȱaȱzoneȱdefinedȱaȱGasȱ detectorȱ Noȱ FloodȱAlertȱ Floodȱalertȱfromȱaȱzoneȱdefinedȱasȱfloodȱtypeȱ Noȱ COȱAlertȱ COȱ(CarbonȱMonoxide)ȱalertȱfromȱaȱzoneȱdefinedȱaȱCOȱ detectorȱ Noȱ Highȱ Temperatureȱ HighȱTemperatureȱalertȱfromȱaȱzoneȱdefinedȱaȱ Temperatureȱdetectorȱ Noȱ LowȱTemperatureȱ LowȱTemperatureȱalertȱfromȱaȱzoneȱdefinedȱaȱ Temperatureȱdetectorȱ Noȱ Technicalȱ Noȱ AlertȱfromȱtheȱzoneȱdefinedȱasȱTechnicalȱ Miscellaneousȱȱ ZoneȱOmitȱ Zoneȱhasȱbeenȱomittedȱȱ Noȱ Periodicȱtestȱ FollowȱMeȱtestȱmessageȱwillȱbeȱestablishedȱfollowingȱ theȱtimeȱdefinedȱinȱtheȱPeriodicȱTestȱparameterȱunderȱ theȱARCȱparametersȱ Noȱ Remoteȱ programmingȱ Systemȱisȱinȱremoteȱinstallationȱmodeȱ Noȱ RestoreȱEvents:ȱ Alarmsȱ ȱ IntruderȱAlarmȱ Intruderȱalarmȱinȱtheȱsystemȱrestoredȱ Yesȱ Tamperȱ Tamperȱalarmȱinȱtheȱsystemȱrestoredȱ Noȱ Faultsȱ ȱ MainȱLowȱBatteryȱ LowȱbatteryȱindicationȱfromȱtheȱAgilityȱmainȱpanelȱ restoredȱ Noȱ WLȱLowȱBatteryȱ Lowȱbatteryȱindicationȱfromȱanyȱwirelessȱdeviceȱinȱtheȱ systemȱrestoredȱ Noȱ Jammingȱ Jammingȱindicationȱinȱtheȱsystemȱrestoredȱ Noȱ WLȱLostȱ Wirelessȱdeviceȱlostȱrestoredȱ Noȱ ACȱOffȱ InterruptionȱinȱtheȱsourceȱofȱtheȱmainȱACȱpowerȱ restoredȱ Noȱ PSTNȱFaultȱ PSTNȱlostȱeventȱrestoredȱ Noȱ IPȱNetworkȱ CommunicationȱfaultȱinȱtheȱIPȱrestoredȱ Noȱ GSMȱFaultȱ GeneralȱGSMȱfaultȱrestoredȱ Noȱ Page 4-64 AgilityȱEngineerȱManualȱ ȱ ȱ Communication: Follow-Me Parameter Default Environmentalȱ ȱ GasȱAlertȱ GasȱAlertȱrestoredȱ Range Noȱ FloodȱAlertȱ FloodȱAlertȱrestoredȱ Noȱ COȱAlertȱ COȱAlertȱrestoredȱ Noȱ Highȱ Temperatureȱ HighȱTemperatureȱAlertȱrestoredȱ Noȱ LowȱTemperatureȱ LowȱTemperatureȱAlertȱrestoredȱ Noȱ Technicalȱ Noȱ TechnicalȱAlertȱrestoredȱ RemoteȱControlȱ ȱ RemoteȱListenȱ ȱ Noȱ ȱ Enablesȱtheȱuserȱofȱtheȱfollowȱmeȱphoneȱtoȱperformȱremoteȱlistenȱandȱtalkȱ operationȱwithȱtheȱpremises.ȱ Remoteȱprogramȱ Noȱ ȱ EnablesȱtheȱuserȱofȱtheȱfollowȱmeȱphoneȱtoȱenterȱtheȱRemoteȱOperationȱmenuȱ andȱperformȱallȱavailableȱprogrammingȱoptions.ȱForȱmoreȱdetailsȱseeȱtheȱUserȱ manual.ȱ Partitionȱ ȱ ȱ Assignȱtheȱpartitionsȱfromȱwhichȱeventsȱwillȱbeȱreportedȱtoȱtheȱfollowȱmeȱnumber.ȱ Controlsȱ ȱ ȱ AllowsȱtoȱprogramȱcontrolȱrelatedȱtoȱoperationȱwithȱtheȱFollowȱMeȱ UnsetȱStopȱFollowȱMeȱ Noȱ ȱ YES:ȱTheȱFollowȬMeȱcallsȱwillȱstopȱwhenȱtheȱpartitionsȱareȱunsetȱbyȱaȱuserȱcodeȱ NO:ȱTheȱFollowȬMeȱcallsȱwillȱcontinueȱtoȱbeȱmadeȱwhenȱtheȱpartitionsȱareȱunsetȱ byȱaȱuserȱcodeȱ Parametersȱ ȱ ȱ AllowsȱtoȱprogramȱparametersȱrelatedȱtoȱoperationȱwithȱtheȱFollowȱMeȱ FollowȱMeȱRetriesȱ 03ȱ 01Ȭ15ȱ TheȱnumberȱofȱtimesȱtheȱFollowȱMeȱphoneȱnumberȱisȱredialedȱ VoiceȱMessageȱRecurrenceȱ 01ȱ 01Ȭ05ȱ Thisȱnumberȱofȱtimesȱaȱvoiceȱmessageȱrepeatsȱitselfȱwhenȱestablishingȱaȱcallȱtoȱaȱ FollowȱMeȱnumber.ȱ Page 4-65 AgilityȱEngineerȱManualȱ ȱ Communication: Follow-Me Parameter Default FollowȱMeȱPeriodicȱTestȱ ȱ Range ȱ TheȱPeriodicȱTestȱenablesȱyouȱtoȱsetȱtheȱtimeȱperiodȱthatȱtheȱsystemȱwillȱ automaticallyȱestablishȱcommunicationȱtoȱaȱFollowȱMeȱdestinationȱdefinedȱwithȱ theȱPeriodicȱTestȱevent.ȱȱ Page 4-66 AgilityȱEngineerȱManualȱ ȱ ȱ 5. Programming: Audio Messages Menu Thisȱmenuȱisȱusedȱtoȱdefineȱvoiceȱmessageȱparameters.ȱTheȱAudioȱMessagesȱmenuȱisȱdividedȱ intoȱtheȱfollowingȱsubȱmenus:ȱ 1.ȱAssignȱMessageȱ 2.ȱLocalȱMessageȱ 5.1 Assign Message Theȱengineerȱcanȱassignȱaȱvoiceȱmessageȱtoȱaȱzone,ȱpartition,ȱoutputȱorȱmacro.ȱWhenȱanȱ eventȱoccursȱthisȱvoiceȱmessageȱwillȱbeȱheardȱaccordingly.ȱȱ Eachȱmessageȱcanȱbeȱcomprisedȱofȱupȱtoȱ4ȱwords.ȱEachȱwordȱhasȱbeenȱpreȬrecordedȱandȱ assignedȱaȱnumber.ȱWhenȱcomprisingȱaȱmessageȱtheȱengineerȱwillȱenterȱtheȱnumberȱofȱeachȱ wordȱintoȱtheȱmessageȱsequence.ȱTheȱsystemȱrecognizesȱtheȱnumbersȱandȱsoundsȱtheȱwordsȱ assignedȱtoȱthoseȱnumbers.ȱ(SeeȱDescriptorȱDirectoryȱbelow)ȱForȱexample:ȱForȱtheȱsystemȱtoȱ soundȱ“TopȱFloorȱGuestȱBedroom”,ȱtheȱengineerȱmustȱenterȱtheȱfollowingȱsequence:ȱ119ȱȱ050ȱȱ 061ȱȱ019.ȱ TheȱtableȱinȱAppendixȱC:ȱLibraryȱVoiceȱMessagesȱdisplaysȱtheȱdirectoryȱofȱtheȱpreȬrecordedȱ programmingȱdescriptors,ȱeachȱisȱidentifiedȱbyȱaȱ3ȱdigitȱnumber.ȱȱ Note:ȱTheȱfirstȱfiveȱdescriptorsȱallowȱforȱcustomizedȱwordsȱspecificȱforȱtheȱclient’sȱneeds.ȱTheȱcustomizedȱ wordsȱcanȱbeȱrecordedȱviaȱtheȱtelephone.ȱEachȱrecordingȱisȱ2ȱsecondsȱlong.ȱ ȱToȱassignȱaȱmessageȱfollowȱthisȱprocedure:ȱ 1.ȱGoȱtoȱProgrammingȱÆȱAudioȱMessagesȱÆȱAssignȱMessage.ȱ 2.ȱSelectȱtheȱrelevantȱdeviceȱandȱgoȱtoȱDefine.ȱ 3.ȱEnterȱtheȱrelevantȱdescriptorȱnumbersȱ(seeȱAppendixȱ3:ȱLibraryȱVoiceȱMessages)ȱandȱȱȱ .ȱ ȱȱȱȱpressȱ 4.ȱGoȱtoȱPlayȱtoȱhearȱtheȱmessage.ȱ 5.2 Local Message Uponȱeventȱoccurrence,ȱtheȱsystemȱcanȱannounceȱtheȱsecurityȱsituationȱtoȱoccupantsȱofȱtheȱ premisesȱbyȱsoundingȱaȱlocalȱannouncementȱmessage.ȱThisȱannouncementȱmessageȱcanȱbeȱ enabledȱorȱdisabled,ȱperȱevent.ȱEnableȱorȱdisableȱeachȱmessageȱannouncementȱaccordingȱtoȱ yourȱcustomerȱrequest.ȱ Audio Messages: Local Messages Parameter Description Intruderȱalarmȱ Intruderȱalarmȱ Default Fireȱalarmȱ Fireȱalarmȱ Yesȱ Emergencyȱ Emergencyȱ(medical)ȱalarmȱ Yesȱ Yesȱ Page 4-67 AgilityȱEngineerȱManualȱ ȱ Audio Messages: Local Messages Parameter Description Panicȱalarmȱ Panicȱalarmȱ Default Yesȱ Tamperȱalarmȱ Tamperȱalarmȱ Yesȱ Environmentalȱ alertȱ Flood,ȱGas,ȱCOȱorȱTemperatureȱalertȱ Yesȱ FullȱSetȱ System/PartitionȱsetȱinȱFullȱSetȱ Yesȱ PartȱSetȱ System/PartitionȱsetȱinȱPartȱSetȱ Yesȱ Unsetȱ System/Partitionȱunsetȱ Yesȱ AudibleȱStatusȱ Statusȱheardȱwhenȱpressingȱtheȱstatusȱbuttonȱonȱtheȱ keypad/remoteȱcontrolȱ Yesȱ Entryȱ/ȱExitȱ Systemȱinȱexitȱorȱentryȱdelayȱ Yesȱ Autoȱsetȱ Systemȱinȱautoȱsetȱprocessȱȱ Yesȱ OutputȱOn/Offȱ Outputȱactivatedȱorȱdeactivatedȱ(Outputsȱdefinedȱasȱ FollowȱCode)ȱ Noȱ Walkȱtestȱ Walkȱtest.ȱTheȱAgilityȱwillȱsoundȱtheȱzoneȱnumberȱandȱ descriptionȱ Yesȱ NoȱMovementȱ Noȱmovementȱmessageȱ Yesȱ Miscellaneousȱ ChimeȱstatusȱandȱMacroȱmessagesȱ Yesȱ Page 4-68 AgilityȱEngineerȱManualȱ ȱ ȱ Testing menu Theȱfollowingȱmenuȱisȱusedȱtoȱperformȱtestsȱonȱtheȱsystem.ȱNoteȱthatȱeachȱtestȱrefersȱtoȱtheȱ lastȱtimeȱtheȱdeviceȱwasȱactivated.ȱTestsȱcanȱbeȱperformedȱonȱtheȱfollowingȱelements:ȱ 1.ȱMainȱUnitȱ 2.ȱZoneȱ 3.ȱRemoteȱControlȱ(Keyfob)ȱ 4.ȱKeypadȱ 5.ȱSounderȱ 6.ȱGSMȱ 7.ȱIPȱUnitȱ 8.ȱPOȱUnitȱ 1. Main Unit Main Unit Parameter NoiseȱLevelȱ ȱ ȱ Thisȱfeatureȱestablishesȱtheȱthresholdȱnoiseȱlevelȱofȱtheȱmainȱunitȱreceiver.ȱTheȱthresholdȱ noiseȱlevelȱcanȱbeȱestablishedȱautomaticallyȱorȱmanuallyȱ(whenȱusingȱaȱkeypad).ȱ Toȱestablishȱtheȱmainȱunitȱreceiverȇsȱnoiseȱlevel:ȱ Automatic:ȱForȱautomaticȱcalibrationȱselectȱ[2]ȱCalibrate.ȱAfterȱtheȱcalibrationȱ processȱisȱaccomplished,ȱtheȱnewȱnoiseȱthresholdȱlevelȱisȱdisplayed.ȱ Manual:ȱForȱmanualȱcalibrationȱselectȱ[1]ȱView/Edit.ȱTheȱvalueȱdisplayedȱisȱtheȱlastȱ measuredȱvalue.ȱSetȱaȱnewȱthresholdȱlevelȱandȱpressȱ Sounderȱ ȱtoȱconfirm.ȱ ȱ ȱ ȱ ȱ Activatesȱtheȱmainȱunitȱsounder.ȱ Speakerȱ Soundsȱtheȱlocalȱtestȱmessage:ȱ“Testȱmessage”.ȱSelectȱStartȱtoȱactivateȱtheȱfeature.ȱSelectȱ Stopȱtoȱendȱtheȱtest.ȱȱȱȱ Batteryȱ ȱ ȱ ȱ ȱ ȱ ȱ Displaysȱtheȱbatteryȱvoltageȱofȱtheȱmainȱunit.ȱ Versionȱ Displaysȱtheȱmainȱunitȇsȱsoftwareȱversion.ȱ SerialȱNumberȱ Displaysȱtheȱmainȱunitȇsȱserialȱnumber.ȱ Page 4-69 AgilityȱEngineerȱManualȱ ȱ 2. Zone Zone Parameter Default CommȱTestȱ Range ȱ 0Ȭ99ȱ Displaysȱtheȱresultsȱofȱtheȱlastȱmeasurementȱperformedȱafterȱtheȱlastȱtransmissionȱ(lastȱ detectionȱorȱlastȱsupervisionȱsignal).ȱToȱreceiveȱanȱupdatedȱsignalȱstrength,ȱactivateȱtheȱ detectorȱpriorȱtoȱperformingȱtheȱcommunicationȱtest.ȱ Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ BatteryȱTestȱ ȱ ȱ Displaysȱtheȱresultsȱofȱtheȱlastȱbatteryȱtestȱperformedȱafterȱtheȱlastȱtransmission.ȱOKȱ messageȱisȱdisplayedȱforȱaȱsuccessfulȱtest.ȱForȱanȱupdatedȱvalueȱactivateȱtheȱdevice.ȱ WalkȱTestȱ Usedȱtoȱeasilyȱtestȱandȱevaluateȱtheȱoperationȱofȱselectedȱzonesȱinȱyourȱsystem.ȱItȱisȱ recommendedȱtoȱperformȱwalkȱtestȱafterȱinstallingȱallȱwirlessȱdevicesȱandȱalsoȱpriorȱtoȱ performingȱTestingȱoperation.ȱ TheȱkeypadȱLCDȱdisplaysȱtheȱfollowingȱinformation:ȱȱ ȱ Zoneȱnumber;ȱTRIP:ȱSuccessfulȱdetection;ȱTMP:ȱTamperȱdetectionȱandȱTrbl:ȱLowȱbatteryȱ Versionȱ Thisȱmenuȱdisplaysȱsoftwareȱversionȱofȱtheȱselectedȱ2Ȭwayȱdetector.ȱȱȱ 3. Remote Control (Keyfob) Remote Control Parameter Default CommȱTestȱ Range ȱ ȱ Displaysȱtheȱresultsȱofȱtheȱlastȱmeasurementȱperformedȱafterȱtheȱlastȱtransmission.ȱToȱ receiveȱanȱupdatedȱsignalȱstrength,ȱactivateȱtheȱremoteȱcontrolȱpriorȱtoȱperformingȱtheȱ communicationȱtest.ȱ Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ BatteryȱTestȱ ȱ ȱ Displaysȱtheȱresultsȱofȱtheȱlastȱbatteryȱtestȱperformedȱafterȱtheȱlastȱtransmission.ȱOKȱ messageȱisȱdisplayedȱforȱaȱsuccessfulȱtest.ȱForȱanȱupdatedȱvalueȱactivateȱtheȱdevice.ȱ Page 4-70 AgilityȱEngineerȱManualȱ ȱ ȱ 4. Keypad Keypad Parameter Default CommȱTestȱ Range ȱ ȱ Displaysȱtheȱresultsȱofȱtheȱlastȱmeasurementȱperformedȱafterȱtheȱlastȱtransmission.ȱToȱ receiveȱupdatedȱsignalȱstrength,ȱactivateȱtheȱkeypadȱpriorȱtoȱperformingȱtheȱ communicationȱtest.ȱ Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ BatteryȱTestȱ ȱ Displaysȱtheȱresultsȱofȱtheȱlastȱbatteryȱtestȱperformedȱafterȱtheȱlastȱ ȱ transmission.ȱOKȱmessageȱisȱdisplayedȱforȱaȱsuccessfulȱtest.ȱForȱanȱ updatedȱvalueȱactivateȱtheȱdevice.ȱ Versionȱ ȱ ȱ ȱ ȱ Thisȱmenuȱdisplaysȱinformationȱregardingȱtheȱkeypadȇsȱversion.ȱ 5. Sounder Sounder Parameter Default CommȱTestȱ Range ȱ ȱ TheȱsounderȱcommunicationȱtestȱperformsȱaȱcommunicationȱtestȱbetweenȱtheȱAgilityȱ andȱtheȱselectedȱsounder.ȱTheȱvalueȱdisplayedȱindicatesȱtheȱsounderȇsȱsignalȱstrengthȱasȱ receivedȱbyȱtheȱAgility.ȱȱȱ Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ BatteryȱTestȱ ȱ ȱ Speakerȱbatteriesȱvoltage:ȱTestsȱtheȱselectedȱsounder’sȱspeakerȱbatteriesȱvoltage.ȱȱȱ Radioȱ(Transceiver)ȱbatteriesȱvoltage:ȱTestsȱtheȱselectedȱsounder’sȱradioȇsȱbatteriesȱ voltage.ȱȱȱ SoundȱTestȱ ȱ Activatesȱsquawkȱsoundȱinȱtheȱselectedȱsounder.ȱ Page 4-71 ȱ AgilityȱEngineerȱManualȱ ȱ Sounder Parameter Default NoiseȱLevelȱ Range ȱ ȱ Thisȱfeatureȱestablishesȱtheȱthresholdȱnoiseȱlevelȱofȱtheȱwirelessȱsounderȱreceiver.ȱTheȱ thresholdȱnoiseȱlevelȱcanȱbeȱestablishedȱautomaticallyȱorȱmanuallyȱ(whenȱusingȱaȱ keypad).ȱ Toȱestablishȱaȱsounderȱreceiverȇsȱnoiseȱlevel:ȱ 1.ȱȱSelectȱtheȱsounderȱforȱwhichȱyouȱwantȱtoȱcalibrateȱitsȱreceiver.ȱ 2.ȱForȱautomaticȱcalibrationȱselectȱ[2]ȱCalibrate.ȱAfterȱtheȱcalibrationȱprocessȱisȱȱ ȱȱȱȱaccomplished,ȱtheȱnewȱnoiseȱthresholdȱlevelȱisȱdisplayed.ȱ 3.ȱForȱmanualȱcalibrationȱselectȱ[1]ȱView/Edit.ȱTheȱvalueȱdisplayedȱisȱtheȱlastȱȱ ȱȱȱȱȱmeasuredȱvalue.ȱSetȱaȱnewȱthresholdȱlevelȱandȱpressȱ ȱtoȱconfirm.ȱ Versionȱ ȱ ȱ Thisȱmenuȱdisplaysȱinformationȱregardingȱtheȱsounderȇsȱversion.ȱ 6. GSM GSM Parameter Default Signalȱ(RSSI)ȱ Range ȱ ȱ DisplaysȱtheȱsignalȱlevelȱmeasuredȱbyȱtheȱGSMȱmodule.ȱ(0=Noȱsignal,ȱ5=ȱVeryȱhighȱ signal)ȱ Versionȱ ȱ ȱ ȱ ȱ DisplaysȱinformationȱregardingȱtheȱGSMȱcardȱversion.ȱ IMEIȱ ViewȱtheȱIMEIȱnumberȱofȱtheȱGSMȱmodule.ȱThisȱnumberȱisȱusedȱforȱidentificationȱofȱtheȱ AgilityȱatȱtheȱRISCOȱIPȱreceiverȱwhenȱusingȱGSMȱorȱGPRSȱcommunication.ȱ 7. IP Unit IP Unit Parameter Default IPȱAddressȱ Range ȱ ȱ ȱ ȱ ViewȱtheȱIPȱaddressȱofȱtheȱAgilityȱ Versionȱ ViewȱtheȱversionȱonȱtheȱIPȱcardȱ Page 4-72 AgilityȱEngineerȱManualȱ ȱ ȱ IP Unit Parameter Default MACȱAddressȱ Range ȱ ȱ ViewȱtheȱMACȱaddressȱofȱtheȱIPȱcard.ȱThisȱnumberȱisȱusedȱforȱidentificationȱofȱtheȱ AgilityȱatȱtheȱRISCOȱIPȱreceiverȱwhenȱusingȱIPȱcommunication.ȱ 8. PO Unit PO Unit Parameter Default CommȱTestȱ Range ȱ ȱ Displaysȱtheȱresultsȱofȱtheȱlastȱmeasurementȱperformedȱafterȱtheȱlastȱtransmission.ȱToȱ receiveȱanȱupdatedȱsignalȱstrength,ȱactivateȱtheȱPOȱunitȱpriorȱtoȱperformingȱtheȱ communicationȱtest.ȱ Forȱsuccessfulȱcommunication,ȱtheȱstrengthȱofȱtheȱsignalȱshouldȱbeȱhigherȱthanȱtheȱnoiseȱ thresholdȱlevelȱasȱmeasuredȱduringȱcalibrationȱofȱtheȱmainȱunit.ȱ BatteryȱTestȱ ȱ ȱ Displaysȱtheȱresultsȱofȱtheȱlastȱbatteryȱtestȱperformedȱafterȱtheȱlastȱtransmission.ȱOKȱ messageȱisȱdisplayedȱforȱaȱsuccessfulȱtest.ȱForȱanȱupdatedȱvalueȱactivateȱtheȱdevice.ȱ Versionȱ ȱ ThisȱmenuȱdisplaysȱinformationȱregardingȱtheȱPOȱunitȇsȱversion.ȱ ȱ Page 4-73 ȱ AgilityȱEngineerȱManualȱ ȱ Activities Menu TheȱengineerȱcanȱperformȱspecialȱactivitiesȱonȱtheȱsystemȱviaȱtheȱActivitiesȱmenu.ȱSomeȱofȱ theseȱactivitiesȱcanȱalsoȱbeȱperformedȱbyȱtheȱuser.ȱ Activities Parameter Default Range MainȱBuzzerȱOn/Offȱ ȱ ȱ Usedȱtoȱactivate/deactivateȱtheȱmainȱunitȱbuzzer.ȱ KPȱSleepȱTimeȱ 10ȱsecondsȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱȱ00Ȭ60ȱsecondsȱ UsedȱtoȱsetȱtheȱkeypadȇsȱSleepȱmodeȱtime.ȱ(TheȱLCDȱdisplayȱisȱturnedȱoff.)ȱ SounderȱTMPȱMuteȱ ȱ ȱ Usedȱtoȱsilenceȱanȱalarmȱinitiatedȱbyȱaȱtamperȱfromȱaȱsounderȱforȱ20ȱminutes.ȱUseȱthisȱ optionȱforȱexample,ȱwhenȱreplacingȱtheȱsounderȱbattery.ȱ AvoidȱReportȱProgrammingȱ ȱ ȱ Someȱprotocolsȱhaveȱaȱreportȱcodeȱtoȱtheȱalarmȱreceivingȱcenterȱforȱenteringȱandȱexitingȱ theȱengineerȱprogramming.ȱToȱavoidȱtheȱenteringȱreportȱandȱsaveȱtime,ȱthisȱfunctionȱ postponesȱtheȱreportȱforȱtwoȱminutesȱduringȱwhichȱtheȱengineerȱcanȱenterȱtheȱ programmingȱmenuȱandȱnoȱreportȱwillȱbeȱmade.ȱ OmitȱBoxȱTamperȱ ȱ ȱ Providesȱabilityȱtoȱomitȱboxȱtamperȱcondition.ȱWhenȱactivatedȱandȱtamperȱconditionȱ occurs,ȱthereȱwillȱbeȱnoȱalarm,ȱnoȱindicationȱtoȱtheȱARCȱandȱnoȱrecordȱinȱtheȱeventȱlog.ȱ Note:ȱToȱenableȱOmitȱBoxȱTamper,ȱbothȱtheȱAllowȱOmitȱandȱ24ȱHourȱOmitȱparametersȱmustȱbeȱsetȱtoȱYESȱ (referȱtoȱpageȱ4Ȭ5ȱandȱpageȱ4Ȭ8ȱforȱmoreȱinformation).ȱ EngineerȱResetȱ ȱ ȱ ȱ ȱ Useȱthisȱoptionȱtoȱresetȱanȱalarm.ȱ ConfigurationȱSoftwareȱConnectȱ Enablesȱtoȱestablishȱremoteȱcommunicationȱwithȱtheȱconfigurationȱsoftwareȱatȱaȱ predefinedȱlocationȱthroughȱIPȱorȱGPRS.ȱ Note:ȱTheȱlocationȱofȱtheȱconfigurationȱsoftwareȱshouldȱbeȱpredefinedȱunderȱ CommunicationÆConfigurationȱSoftwareÆIPȱGatewayȱ FirmwareȱUpdateȱ ȱ ȱ Thisȱoptionȱactivatesȱaȱfirmwareȱupdateȱprocess.ȱTheȱupdateȱcanȱbeȱestablishedȱthroughȱ IPȱorȱGPRS.ȱȱTheȱlocationȱofȱtheȱnewȱfirmwareȱshouldȱbeȱpredefinedȱunderȱEngineerȱ ProgrammingÆȱSystemÆFirmwareȱUpdate.ȱ Onceȱtheȱcommunicationȱmethodȱisȱselectedȱ(IPȱorȱGPRS)ȱaȱspecialȱmanufacturerȱ passwordȱshouldȱbeȱentered.ȱPleaseȱreferȱtoȱyourȱlocalȱRISCOȱbranchȱforȱthisȱpassword.ȱ Page 4-74 AgilityȱEngineerȱManualȱ ȱ ȱ Follow Me Menu Follow Me Parameter Defineȱ UsedȱtoȱdefineȱFollowȱMeȱdestinationsȱphoneȱnumberȱorȱEȬmailȱaddressȱaccordingȱtoȱitsȱ type:ȱVoiceȱmessage,ȱSMSȱorȱEȬmailȱ TestȱFMȱ UsedȱtoȱtestȱFollowȱMeȱreporting.ȱ Clock Menu Clock Parameter Default Range Timeȱ+ȱDateȱ ȱ ȱ Allowsȱtheȱsettingȱofȱtheȱsystemȱtimeȱandȱdate.ȱThisȱdefinitionȱisȱrequiredȱforȱsettingȱtheȱ schedulerȱprogrammingȱinȱtheȱsystem.ȱ Schedulerȱ ȱ On/Offȱ Enablesȱyouȱtoȱactivateȱorȱdeactivateȱpreprogrammedȱschedulesȱthatȱwereȱdefinedȱbyȱ yourȱengineer.ȱUpȱtoȱ8ȱweeklyȱprogramsȱcanȱbeȱdefinedȱinȱtheȱsystemȱduringȱwhichȱtheȱ systemȱautomaticallyȱsetsȱ/ȱunsetsȱorȱactivatesȱprogrammingȱoutputs.ȱ Note:ȱTheȱdefinitionȱofȱtheȱschedulingȱprogramsȱisȱdoneȱfromȱtheȱconfigurationȱsoftware.ȱ AutomaticȱClockȱ ȱ ȱ UsedȱtoȱgetȱanȱautomaticȱtimeȱupdateȱthroughȱtheȱIPȱnetworkȱorȱGPRS.ȱ Serverȱ SelectȱtheȱInternetȱtimeȱprotocolȱNTPȱorȱDaytime.ȱ Hostȱ TheȱIPȱaddressȱorȱserverȱname.ȱ Portȱ Theȱserverȱport.ȱ TimeȱZoneȱ(GMT/UTC)ȱ Useȱtheȱ ȱkeyȱtoȱaddȱanȱhourȱtoȱtheȱGMT/UTCȱtime.ȱUseȱtheȱ subtractȱanȱhourȱfromȱtheȱGMT/UTCȱtime.ȱ Page 4-75 ȱkeyȱtoȱ AgilityȱEngineerȱManualȱ ȱ Event Log Menu Allowsȱtheȱviewingȱofȱsignificantȱsystemȱeventsȱincludingȱdateȱandȱtime.ȱScrollȱtheȱlistȱ usingȱtheȱarrowȱkeysȱtoȱviewȱtheȱeventsȱinȱtheȱsystem.ȱȱ Macro Menu Programming Macro Keys AgilityȱenablesȱtheȱEngineerȱorȱGrandȱMasterȱtoȱrecordȱaȱseriesȱofȱcommandsȱandȱassignȱ themȱtoȱaȱmacro.ȱWhenȱtheȱmacroȱisȱpressed,ȱtheȱrecordedȱcommandsȱareȱexecutedȱfromȱ beginningȱtoȱend.ȱUpȱtoȱ3ȱmacrosȱcanȱbeȱprogrammedȱtoȱaȱsystemȱusingȱtheȱAgilityȱkeypadȱ orȱtheȱAgilityȱConfigurationȱSoftware.ȱȱ Beforeȱprogrammingȱaȱmacro,ȱitȱisȱrecommendedȱtoȱperformȱyourȱrequiredȱseriesȱofȱ commands,ȱmakingȱaȱnoteȱofȱeveryȱkeyȱyouȱpressȱwhileȱdoingȱso.ȱ Note:ȱMacrosȱcannotȱbeȱprogrammedȱtoȱperformȱdisarmingȱcommands.ȱ Toȱprogramȱaȱmacro:ȱ .ȱ 1. InȱtheȱMacroȱmenuȱselectȱaȱmacroȱ(A,ȱBȱorȱC)ȱandȱpress 2. Enterȱtheȱsequenceȱofȱcharactersȱaccordingȱtoȱtheȱfollowingȱtable:ȱ Key Represents Usedȱtoȱenterȱnumericalȱcharactersȱ ȱ ȱ Usedȱtoȱmoveȱtheȱcurserȱtoȱtheȱleftȱ Usedȱtoȱmoveȱtheȱcurserȱtoȱtheȱrightȱ ȱ Pressȱ1ȱtwiceȱ RepresentsȱtheȱÇȱcharacterȱ Pressȱ3ȱtwiceȱ RepresentsȱtheȱÈȱcharacterȱ Pressȱ4ȱtwiceȱ Representsȱtheȱ ȱkeyȱ Pressȱ6ȱtwiceȱ Representsȱtheȱ ȱkeyȱ Pressȱ7ȱtwiceȱ Representsȱtheȱ¾ȱcharacterȱ Pressȱ9ȱtwiceȱ Representsȱtheȱ#ȱcharacterȱ ȱandȱ0ȱsimultaneouslyȱ Deletesȱyourȱentryȱfromȱtheȱcursorȱpositionȱforwardȱ Page 4-76 AgilityȱEngineerȱManualȱ Key ȱ Represents / Useȱtoȱtoggleȱbetweenȱ numericȱcharactersȱ / /Ç/È/#/¾ȱandȱallȱofȱtheȱ Usedȱtoȱendȱtheȱsequenceȱandȱsaveȱitȱtoȱmemoryȱ 3. Press ȱtoȱsaveȱyourȱentry.ȱȱ Theȱseriesȱofȱcharactersȱisȱsavedȱandȱassignedȱtoȱtheȱselectedȱmacro.ȱ ȱ Forȱexample:ȱ Toȱsetȱpartitionȱ1ȱwithȱtheȱcodeȱ1234,ȱenterȱtheȱfollowingȱsequence:ȱ ȱȱ1ȱ ȱ1ȱ2ȱ3ȱ4ȱ Activating a Macro Pressȱ7/8/9ȱonȱtheȱkeypadȱforȱ2ȱsecondsȱtoȱactivateȱtheȱmacroȱA/B/Cȱrespectively.ȱAȱ confirmationȱmessageȱwillȱbeȱheard:ȱȱ Ȉ[MacroȱX]ȱactivatedȈ.ȱ ȱ ȱ ȱ Page 4-77 ȱ AgilityȱEngineerȱManualȱ ȱ Appendix A Report Codes Report Codes Parameter Contact ID SIA Alarmsȱȱȱ ȱ ȱ Panicȱalarmȱ 120ȱ PAȱ Urgentȱ Panicȱalarmȱrestoreȱ 120ȱ PHȱ Urgentȱ Fireȱalarmȱ 115ȱ FAȱ Urgentȱ Fireȱalarmȱrestoreȱ 115ȱ FHȱ Urgentȱ Medicalȱalarmȱ 100ȱ MAȱ Urgentȱ Medicalȱalarmȱrestoreȱ 100ȱ MHȱ Urgentȱ Duressȱalarmȱ 121ȱ HAȱ Urgentȱ Duressȱalarmȱrestoreȱ 121ȱ HHȱ Urgentȱ Boxȱtamperȱ 137ȱ TAȱ Urgentȱ Boxȱtamperȱrestoreȱ 137ȱ TRȱ Urgentȱ Confirmedȱalarmȱ 139ȱ BVȱ Urgentȱ Confirmedȱalarmȱrestoreȱ 139ȱ ȱ Urgentȱ RecentȱCloseȱ 459ȱ ȱ NonȬȱurgentȱ MainȱFaultsȱȱ ȱ ȱ Lowȱbatteryȱ 302ȱ YTȱ NonȬȱurgentȱ Lowȱbatteryȱrestoreȱ 302ȱ YRȱ NonȬȱurgentȱ ACȱlossȱ 301ȱ ATȱ NonȬȱurgentȱ ACȱrestoreȱ 301ȱ ARȱ NonȬȱurgentȱ Clockȱnotȱsetȱ 626ȱ ȱ NonȬȱurgentȱ Clockȱsetȱ 625ȱ ȱ NonȬȱurgentȱ Falseȱcodeȱ 421ȱ JAȱ NonȬȱurgentȱ Falseȱcodeȱrestoreȱ 421ȱ ȱ NonȬȱurgentȱ Mainȱphoneȱfaultȱ 351ȱ LTȱ NonȬȱurgentȱ Mainȱphoneȱfaultȱrestoreȱ 351ȱ LRȱ NonȬȱurgentȱ RFȱJammingȱ 344ȱ XQȱ NonȬȱurgentȱ RFȱJammingȱrestoreȱ 344ȱ XHȱ NonȬȱurgentȱ GSMȱfaultȱ 330ȱ IAȱ NonȬȱurgentȱ GSMȱfaultȱrestoreȱ 330ȱ IRȱ NonȬȱurgentȱ Page A-1 Report Category ȱ AgilityȱEngineerȱManualȱ ȱ Report Codes Parameter Contact ID SIA Report Category GSMȱPreȬAlarmȱ ȱ ȱ NonȬȱurgentȱ IPȱNetworkȱfaultȱ ȱ ȱ NonȬȱurgentȱ NonȬȱurgentȱ IPȱNetworkȱtroubleȱrestoreȱ ȱ ȱ Set/Unsetȱȱ ȱ ȱ UserȱSetȱ 401ȱ CLȱ Set/Unsetȱ UserȱUnsetȱ 401ȱ OPȱ Set/Unsetȱ PartȱSetȱ 441ȱ CGȱ Set/Unsetȱ Unsetȱafterȱalarmȱ 458ȱ ORȱ Set/Unsetȱ KeyswitchȱSetȱ 409ȱ CSȱ Set/Unsetȱ KeyswitchȱUnsetȱ 409ȱ OSȱ Set/Unsetȱ AutoȱSetȱ 403ȱ CAȱ Set/Unsetȱ AutoȱUnsetȱ 403ȱ OAȱ Set/Unsetȱ RemoteȱSetȱ 407ȱ CLȱ Set/Unsetȱ RemoteȱUnsetȱ 407ȱ OPȱ Set/Unsetȱ ForcedȱSetȱ 574ȱ CFȱ Set/Unsetȱ QuickȱSetȱ 408ȱ CLȱ Set/Unsetȱ NoȱSetȱ 654ȱ CDȱ Set/Unsetȱ AutoȱSetȱfailȱ 455ȱ CIȱ Set/Unsetȱ Detectors(Zones)ȱȱ ȱ ȱ Burglaryȱalarmȱ 130ȱ BAȱ Burglaryȱalarmȱrestoreȱ 130ȱ BHȱ Urgentȱ Fireȱalarmȱ 110ȱ FAȱ Urgentȱ Fireȱalarmȱrestoreȱ 110ȱ FHȱ Urgentȱ Foilȱalarmȱ 155ȱ BAȱ Urgentȱ Foilȱalarmȱrestoreȱ 155ȱ BHȱ Urgentȱ Panicȱalarmȱ 120ȱ PAȱ Urgentȱ Panicȱalarmȱrestoreȱ 120ȱ PHȱ Urgentȱ Medicalȱalarmȱ 100ȱ MAȱ Urgentȱ Urgentȱ Medicalȱalarmȱrestoreȱ 100ȱ MHȱ Urgentȱ 24ȱHourȱalarmȱ 133ȱ BAȱ Urgentȱ 24ȱHourȱalarmȱrestoreȱ 133ȱ BHȱ Urgentȱ Page A-2 AgilityȱEngineerȱManualȱ ȱ Report Codes Parameter Contact ID SIA Report Category Entry/Exitȱ 134ȱ BAȱ Urgentȱ Entry/Exitȱrestoreȱ 134ȱ BHȱ Urgentȱ Waterȱ(Flood)ȱalarmȱ 154ȱ WAȱ Urgentȱ Waterȱ(Flood)ȱalarmȱrestoreȱ 154ȱ WHȱ Urgentȱ Gasȱalarmȱ 151ȱ GAȱ Urgentȱ Gasȱalarmȱrestoreȱ 151ȱ GHȱ Urgentȱ CarbonȱMonoxideȱalarmȱ 162ȱ GAȱ Urgentȱ CarbonȱMonoxideȱalarmȱrestoreȱ 162ȱ GHȱ Urgentȱ Environmentalȱalarmȱ 150ȱ UAȱ Urgentȱ Environmentalȱalarmȱrestoreȱ 150ȱ UHȱ Urgentȱ LowȱTemperatureȱ(Freezeȱalarm)ȱ 159ȱ ZAȱ Urgentȱ LowȱTemperatureȱrestoreȱ 159ȱ ZHȱ Urgentȱ HighȱTemperatureȱ 158ȱ KAȱ Urgentȱ HighȱTemperatureȱrestoreȱ 158ȱ KHȱ Urgentȱ Zoneȱfaultȱȱ 380ȱ UTȱ Urgentȱ Zoneȱfaultȱrestoreȱ 380ȱ UJȱ Urgentȱ Burglaryȱfaultȱ 380ȱ BTȱ Urgentȱ Burglaryȱfaultȱrestoreȱ 380ȱ BJȱ Urgentȱ Zoneȱomitȱ 570ȱ UBȱ Urgentȱ Zoneȱomitȱrestoreȱ 570ȱ UUȱ Urgentȱ Burglaryȱomitȱ 573ȱ BBȱ Urgentȱ Burglaryȱomitȱrestoreȱ 573ȱ BUȱ Urgentȱ Zoneȱsupervisionȱlossȱ 381ȱ UTȱ Urgentȱ Zoneȱsupervisionȱrestoreȱȱ 381ȱ UJȱ Urgentȱ Tamperȱ 144ȱ TAȱ Urgentȱ Tamperȱrestoreȱ 144ȱ TRȱ Urgentȱ Zoneȱlostȱ 381ȱ UTȱ Urgentȱ Zoneȱlostȱrestoreȱ 381ȱ UJȱ Urgentȱ Lowȱbatteryȱȱ 384ȱ XTȱ NonȬȱurgentȱ Lowȱbatteryȱrestoreȱ 384ȱ XRȱ NonȬȱurgentȱ Soakȱfailȱ 380ȱ UTȱ Urgentȱ Page A-3 ȱ AgilityȱEngineerȱManualȱ ȱ Report Codes Parameter Contact ID SIA Report Category Soakȱfailȱrestoreȱ 380ȱ UJȱ Urgentȱ ZoneȱAlarmȱ 130ȱ BAȱ Urgentȱ ZoneȱAlarmȱrestoreȱ 130ȱ BHȱ Urgentȱ Zoneȱconfirmȱalarmȱ 139ȱ BVȱ Urgentȱ Zoneȱconfirmȱalarmȱrestoreȱ 139ȱ ȱ Urgentȱ Noȱactivityȱ 393ȱ NCȱ Urgentȱ Noȱactivityȱrestoreȱ 393ȱ NSȱ Urgentȱ WirelessȱKeypadȱȱ ȱ ȱ Tamperȱ 145ȱ TAȱ Urgentȱ Tamperȱrestoreȱ 145ȱ TRȱ Urgentȱ Lowȱbatteryȱ 384ȱ XTȱ NonȬȱurgentȱ Lowȱbatteryȱrestoreȱ 384ȱ XRȱ NonȬȱurgentȱ Keypadȱlostȱ 355ȱ BZȱ Urgentȱ Keypadȱlostȱrestoreȱ 355ȱ ȱ Urgentȱ WirelessȱKeyfobȱȱ ȱ ȱ Setȱ 409ȱ CSȱ Set/Unsetȱ Unsetȱ 409ȱ OSȱ Set/Unsetȱ Lowȱbatteryȱȱ 384ȱ XTȱ NonȬȱurgentȱ Lowȱbatteryȱrestoreȱ 384ȱ XRȱ NonȬȱurgentȱ WirelessȱSounderȱ ȱ ȱ Tamperȱ 145ȱ TAȱ Urgentȱ Tamperȱrestoreȱ 145ȱ TRȱ Urgentȱ Lowȱbatteryȱ 384ȱ XTȱ NonȬȱurgentȱ Lowȱbatteryȱrestoreȱ 384ȱ XRȱ NonȬȱurgentȱ Sounderȱlostȱ 355ȱ BZȱ Urgentȱ Sounderȱlostȱrestoreȱ 355ȱ ȱ Urgentȱ WirelessȱI/OȱExpanderȱ ȱ ȱ Lowȱbatteryȱ 384ȱ XTȱ NonȬȱurgentȱ Lowȱbatteryȱrestoreȱ 384ȱ XRȱ NonȬȱurgentȱ I/OȱExpanderȱlostȱ 355ȱ BZȱ Urgentȱ I/OȱExpanderȱlostȱrestoreȱ 355ȱ ȱ Urgentȱ Page A-4 AgilityȱEngineerȱManualȱ ȱ Report Codes Parameter Contact ID SIA Report Category Tamperȱ 145ȱ TAȱ Urgentȱ Tamperȱrestoreȱ 145ȱ TRȱ Urgentȱ ACȱfaultȱ 301ȱ ATȱ NonȬȱurgentȱ ACȱfaultȱrestoreȱ 301ȱ ARȱ NonȬȱurgentȱ RFȱJammingȱ 380ȱ XQȱ Urgentȱ RFȱJammingȱrestoreȱ 380ȱ XHȱ Urgentȱ Miscellaneousȱȱ ȱ ȱ Enterȱprogrammingȱ(Local)ȱ 627ȱ LBȱ Set/Unsetȱ Exitȱprogrammingȱ(Local)ȱ 628ȱ LSȱ(LXȱ)ȱ Set/Unsetȱ Enterȱprogrammingȱ(Remote)ȱ 627ȱ RBȱ Set/Unsetȱ Exitȱprogrammingȱ(Remote)ȱ 628ȱ RSȱ Set/Unsetȱ ARCȱperiodicȱtestȱ 602ȱ RPȱ NonȬȱurgentȱ ARCȱkeepȱaliveȱ(polling)ȱ 999ȱ ZZȱ Urgentȱ Callȱbackȱ 411ȱ RBȱ NonȬȱurgentȱ Systemȱresetȱ 305ȱ RRȱ Urgentȱ Listenȱinȱbeginȱ 606ȱ LFȱ Urgentȱ CancelȱReportȱ 406ȱ OCȱ Urgentȱ WalkȱTestȱ 607ȱ BCȱ NonȬȱurgentȱ WalkȱTestȱrestoreȱ 607ȱ ȱ NonȬȱurgentȱ ExitȱErrorȱ 374ȱ ȱ NonȬȱurgentȱ ȱ ȱ Page A-5 ȱ AgilityȱEngineerȱManualȱ ȱ Appendix B Engineer Event Log Messages EventȱMessageȱ ActivateȱPO=xxȱȱȱ ActvȱPO=xxȱKF=zzȱ AlarmȱabortȱP=yȱȱ Descriptionȱ POȱXXȱactivationȱ POȱXXȱisȱactivatedȱfromȱremoteȱcontrolȱZZȱ AlarmȱabortedȱonȱpartitionȱYȱ AlarmȱZone=xxȱȱȱȱ AntiȬcodeȱresetȱȱ ARC=yȱcallȱerrorȱ ARC=yȱrestoreȱ AutoȱAddȱGSMȱȱȱȱȱ AutoȱAddȱIPȱcardȱ AutoȱAddȱMODEMȱȱȱ AutoȱDelȱGSMȱȱȱȱȱ AutoȱDelȱIPȱcardȱ AutoȱDelȱMODEMȱȱȱ Autoȱtestȱfailȱȱȱ AutoȱtestȱOKȱȱȱȱȱ Bellȱtamperȱȱ Bellȱtamperȱrstȱȱ Boxȱtamperȱȱȱȱȱȱȱ Boxȱtamperȱrstȱȱȱ Alarmȱinȱzoneȱno.ȱXXȱ Remoteȱresetȱ CommunicationȱfailȱfaultȱtoȱARCȱphoneȱno.ȱYȱ CommunicationȱfailȱfaultȱrestoreȱtoȱARCȱphoneȱno.ȱYȱ GSMȱModuleȱaddedȱtoȱtheȱmainȱunitȱ IPȱModuleȱaddedȱtoȱtheȱmainȱunitȱ Modemȱaddedȱtoȱtheȱmainȱunitȱ GSMȱModuleȱwasȱremovedȱfromȱtheȱmainȱunitȱ IPȱModuleȱremovedȱfromȱtheȱmainȱunitȱ Modemȱremovedȱfromȱtheȱmainȱunitȱ FailureȱofȱzoneȱselfȬtestȱ AutomaticȱzoneȱselfȬtestȱOKȱ Bellȱtamperȱalarmȱ Bellȱtamperȱalarmȱrestoreȱ Boxȱtamperȱalarmȱfromȱmainȱunitȱ Boxȱtamperȱalarmȱrestoreȱ CancelȱAlarmȱP=xȱ CancelȱalarmȱeventȱhasȱoccurredȱfromȱpartitionȱX.ȱAȱvalidȱ userȱfunctionȱisȱenteredȱtoȱresetȱtheȱalarmȱafterȱtheȱdefinedȱ Abortȱalarmȱtimeȱ ChangingȱuserȱcodeȱXXȱ ChangingȱFollowȬMeȱnumberȱYYȱbyȱuserȱno.ȱXXȱ ChangingȱkeypadȱtagȱforȱuserȱXXȱ Timeȱisȱnotȱsetȱ Timeȱdefinedȱbyȱuserȱno.ȱXXȱ COȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱCOȱdetectorȱ COȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱCOȱdetectorȱ CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱIPȱcardȱ CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱSounderȱYȱ CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱGSMȱ CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱI/Oȱmoduleȱ ConfirmedȱalarmȱoccurredȱinȱpartitionȱYȱ Restoreȱzoneȱconfirmedȱalarmȱ ConfirmedȱalarmȱoccurredȱfromȱzoneȱXXȱ Theȱcontrolȱpanelȱhasȱresetȱ Dateȱdefinedȱbyȱuserȱno.ȱXXȱ DailyȱsetȱonȱpartitionȱYȱ DailyȱPartȱSettingȱinȱpartitionȱYȱȱ Changeȱcode=xxȱȱȱ ChangeȱFM=yyȱC=xxȱȱȱȱȱ Changeȱtag=xxȱȱȱȱ Clockȱnotȱsetȱȱȱȱ ClockȱsetȱC=xxȱȱȱ COȱAlarmȱZn=xxȱȱȱ COȱRst.ȱZn=xxȱȱȱȱ ComȱokȱIPȱcardȱȱȱ CommȱOKȱSoundr=yȱ Comm.ȱOKȱGSMȱȱȱȱȱ Comm.OKȱI/OȱMdl.ȱ Conf.ȱalarmȱP=yȱȱ ConfirmȱrsȱZ=xxȱȱ ConfirmȱZone=xxȱȱ CPȱresetȱȱȱȱȱȱȱȱȱ DateȱsetȱC=xxȱȱȱȱ DayȱF.Set:P=yȱȱȱȱȱ DayȱP.Set:P=yȱȱȱ Page B-1 ȱ AgilityȱEngineerȱManualȱ ȱ EventȱMessageȱ DayȱUnset:ȱP=yȱȱȱȱȱ DuressȱC=xxȱȱȱȱȱȱ Enterȱprogramȱȱȱȱ ExitȱErrorȱZn=xxȱ Exitȱprogramȱȱȱȱȱ F.FaultȱOKȱZ=xxȱ Descriptionȱ DailyȱunsetȱonȱpartitionȱYȱ Duressȱalarmȱfromȱuser no.ȱXXȱ Enteringȱengineerȱprogrammingȱfromȱkeypadȱorȱ configurationȱsoftwareȱ ExitȱerrorȱeventȱfromȱzoneȱXXȱ Theȱzoneȱwasȱleftȱopenȱatȱtheȱendȱofȱtheȱexitȱtimeȱ Exitingȱengineerȱprogrammingȱfromȱkeypadȱorȱ configurationȱsoftwareȱ Restoreȱfireȱalarmȱinȱzoneȱno.ȱXXȱ F.SetȱfailȱP=yȱ PartitionȱYȱfailedȱtoȱsetȱ F.Set:P=yȱC=xxȱ PartitionȱYȱsetȱbyȱuserȱno.ȱXXȱ F.Set:P=yȱKF=zzȱ PartitionȱYȱsetȱbyȱremoteȱcontrolȱZZȱ Falseȱcodeȱȱȱȱȱȱȱ Falseȱcodeȱalarmȱ Falseȱcodeȱrest.ȱȱȱȱ FireȱfaultȱZn=xxȱ FireȱKeypad=yȱȱȱȱ FireȱZone=xxȱȱȱȱȱ FoilȱokȱZ=xxȱȱȱȱȱ Falseȱcodeȱalarmȱrestoreȱ Faultȱinȱfireȱzoneȱno.ȱXXȱ FireȱalarmȱfromȱwirelessȱkeypadȱYȱ Fireȱalarmȱinȱzoneȱno.ȱXXȱ Restoreȱinȱfoilȱ(Day)ȱzoneȱno.ȱXXȱ FoilȱZone=xxȱȱȱȱȱ ForcedȱsetȱP=yȱȱȱȱȱȱ FoundȱZone=xxȱȱȱȱ GasȱAlarmȱZn=xxȱȱ Faultȱinȱfoilȱ(Day)ȱzoneȱno.ȱXXȱ PartitionȱYȱisȱforceȱsetȱ Wirelessȱzoneȱfound,ȱzoneȱno.ȱXXȱ Gasȱ(naturalȱgas)ȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱgasȱ detectorȱ Gasȱ(naturalȱgas)ȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ gasȱdetectorȱ IPȱaddressȱisȱincorrectȱ IPȱconnectionȱOKȱ CommunicationȱbetweenȱtheȱGSM/GPRSȱModuleȱandȱtheȱ AgilityȱisȱOKȱ InternalȱGSM/GPRSȱBUSȱmoduleȱfaultȱ GSMȱnetworkȱisȱnotȱavailableȱ GSMȱNetworkȱisȱavailableȱ GSMȱNetworkȱqualityȱisȱacceptableȱ TheȱGSMȱRSSIȱlevelȱisȱlowȱ GasȱRst.ȱZn=xxȱȱȱ GSM:IPȱFaultȱ GSM:IPȱOKȱȱȱȱȱȱȱȱ GSM:Mdlȱcomm.OKȱȱ GSM:ȱModuleȱcomm.ȱ GSM:NETȱavail.ȱȱȱ GSM:NETȱavail.OKȱ GSM:NETȱqual.OKȱȱ GSM:NETȱqualityȱȱ GSM:PINȱcodeȱerrȱ GSM:PINȱcodeȱOKȱȱ GSM:PUKȱCodeȱerrȱ GSM:PUKȱCodeȱOKȱȱ GSM:SIMȱfaultȱ GSM:SIMȱOKȱȱȱȱȱȱȱ H.TempȱrstȱZn=xxȱ PINȱcodeȱenteredȱisȱincorrectȱ PINȱcodeȱisȱcorrectȱ PUKȱcodeȱrequiredȱ PUKȱCodeȱenteredȱisȱcorrect SIMȱcardȱmissingȱorȱnotȱproperlyȱsitedȱ SIMȱCardȱinȱplaceȱ HighȱtemperatureȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ temperatureȱdetectorȱ Page B-2 AgilityȱEngineerȱManualȱ EventȱMessageȱ HighȱTemp.ȱZn=xxȱ ȱ IPC:ȱARC=xȱErrorȱ IPC:ȱARC=xȱOKȱ IPC:ȱDHCPȱerrorȱȱȱ IPC:ȱDHCPȱokȱȱȱȱȱȱ Descriptionȱ HighȱtemperatureȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱ temperatureȱdetectorȱ ACȱpowerȱfaultȱonȱI/Oȱmoduleȱ ACȱpowerȱrestoreȱonȱI/Oȱmoduleȱ I/Oȱmoduleȱbatteryȱfaultȱalertȱ I/Oȱmoduleȱbatteryȱfaultȱrestoredȱȱ I/Oȱmoduleȱcommunicationȱfaultȱrestoredȱ I/Oȱmoduleȱcommunicationȱfaultȱ I/Oȱmoduleȱjammingȱalertȱ I/Oȱmoduleȱjammingȱalertȱrestoredȱ I/Oȱmoduleȱisȱregardedȱasȱlostȱfollowingȱsupervisionȱtestȱ I/Oȱmoduleȱtamperȱalertȱ I/Oȱmoduleȱtamperȱalertȱrestoredȱ TheȱAgilityȱreceivedȱaȱsignalȱfromȱI/Oȱmoduleȱafterȱitȱhasȱ beenȱregardedȱasȱlostȱ CommunicationȱfailureȱtoȱARCȱXȱoverȱIPȱnetworkȱ CommunicationȱtoȱARCȱXȱoverȱIPȱnetworkȱisȱOKȱ FailedȱtoȱacquireȱanȱIPȱaddressȱfromȱtheȱDHCPȱserverȱ SucceeededȱtoȱacquireȱanȱIPȱaddressȱfromȱtheȱDHCPȱserverȱ IPC:ȱDownloadȱerrȱ IPC:ȱDownloadȱokȱȱ IPC:ȱHardwareȱerrȱ IPC:ȱHardwareȱokȱȱ IPC:ȱMailȱerrorȱȱȱ IPC:ȱMailȱokȱȱȱȱȱȱ Failedȱtoȱdownloadȱfromȱupgradeȱserverȱ Successfulȱdownloadȱfromȱupgradeȱserverȱ InternalȱhardwareȱerrorȱinȱtheȱIPȱcardȱ NoȱhardwareȱerrorȱinȱtheȱIPȱcardȱ IPȱcardȱfailedȱtoȱsendȱanȱEmailȱ IPȱcardȱsuccessfullyȱsentȱanȱEmailȱ IPC:ȱNetworkȱerrȱȱ IPC:ȱNetworkȱokȱȱȱ IPC:ȱNTPȱerrorȱȱȱȱ IPC:ȱNTPȱokȱȱȱȱȱȱȱ IPC:ȱUpgradeȱerrȱȱ FailedȱtoȱconnectȱtoȱIPȱnetworkȱ SuccessfulȱconnectionȱtoȱIPȱnetworkȱ Failedȱtoȱacquireȱtimeȱdataȱfromȱtheȱtimeȱserverȱ Succeededȱtoȱacquireȱtimeȱdataȱfromȱtheȱtimeȱserverȱ RemoteȱsoftwareȱupgradeȱofȱtheȱIPȱcardȱfailedȱ IPC:ȱUpgradeȱokȱȱȱ JammingȱOKȱZn=xxȱ Jammingȱrestoreȱȱ RemoteȱsoftwareȱupgradeȱofȱtheȱIPȱcardȱsucceededȱȱ ZoneȱXXȱjammingȱOKȱ Wirelessȱreceiverȱȱjammingȱrestoreȱ JammingȱZone=xxȱȱȱȱȱ KP=yȱLowȱBat.Rstȱ KP=yȱLowȱBatteryȱ KswȱF.Set:P=yȱȱȱȱȱ KswȱUnset:P=yȱȱȱ L.batȱrstrȱKF=yyȱ L.TempȱrstȱZn=xxȱ ZoneȱXXȱjammingȱfaultȱ LowȱbatteryȱfaultȱrestoredȱfromȱkeypadȱYȱ LowȱbatteryȱfaultȱfromȱkeypadȱYȱ PartitionȱYȱisȱsetȱbyȱkeyȱswitchȱ PartitionȱYȱisȱunsetȱbyȱkeyȱswitchȱ LowȱbatteryȱfaultȱrestoreȱfromȱwirelessȱremoteȱcontrolȱYYȱ LowȱtemperatureȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ temperatureȱdetectorȱ IfȱtheȱphoneȱlineȱisȱcutȱorȱtheȱDCȱlevelȱisȱunderȱ1Vȱ I/O:ȱACȱFaultȱ I/O:ȱACȱRestoreȱȱȱȱȱȱ I/O:ȱBatteryȱFltȱ I/O:ȱBateryȱRstrȱ I/O:ȱCommȱRestoreȱ I/O:ȱComm.ȱFaultȱȱ I/O:ȱJammingȱȱȱȱȱȱ I/O:ȱJammingȱRstrȱ I/O:ȱLostȱȱȱȱȱȱȱȱȱ I/O:ȱTamperȱȱȱȱȱȱȱ I/O:ȱTamperȱRstrȱȱ I/O:ȱLostȱRestoreȱȱ Lineȱfaultȱ Page B-3 ȱ AgilityȱEngineerȱManualȱ ȱ EventȱMessageȱ Lineȱrestoreȱ LostȱZone=xxȱȱȱȱȱ LowȱBatȱrsȱZ=xxȱȱ Lowȱbat.ȱZn=xxȱȱȱ Lowȱbat.KF=yyȱȱȱȱ LowȱTemp.ȱZn=xxȱȱ Main:ACȱlostȱ Main:ACȱrestoreȱȱ Main:ȱbatteryȱrstȱ Main:ȱlowȱbatteryȱ MsgȱBoxȱTamperȱ MsgȱBoxȱTmpȱRst.ȱ NoȱComȱIPȱcardȱȱȱ NoȱcommȱI/OȱMdl.ȱ NoȱcommȱSoundr=yȱȱ Noȱcomm.ȱGSMȱȱȱȱȱ OmitȱBox+Bellȱ OmitȱFaultȱC=xxȱ OmitȱZone=xxȱ P.Set:P=yȱC=zzȱȱȱȱ P.Set:ȱP=yȱKF=zzȱȱȱ PanicȱKeypad=yȱȱ PanicȱKF=yyȱȱȱȱȱ PTM:ȱSendȱDataȱȱȱȱ Radioȱl.batȱȱS=yȱ Radioȱl.batȱrS=yȱ RemoteȱF.Set:P=yȱȱ RemoteȱP.Set:P=yȱ Remoteȱprogramȱȱȱ RemoteȱUnset:P=xȱ RestoreȱZone=xxȱȱ RFȱJammingȱȱȱȱȱȱȱ Sndr=yȱLostȱRstȱ SoakȱfailȱZ=xxȱȱȱ Sounder=yȱLostȱȱȱȱȱ SpecialȱKP=yȱȱȱȱȱ Descriptionȱ Phoneȱlineȱfaultȱrestoreȱ Wirelessȱzoneȱlost,ȱzoneȱno.ȱXXȱ Lowȱbatteryȱfaultȱrestoredȱfromȱwirelessȱzoneȱno.ȱXXȱ Lowȱbatteryȱfaultȱfromȱwirelessȱzoneȱno.ȱXXȱ LowȱbatteryȱfaultȱfromȱwirelessȱremoteȱcontrolȱXXȱ LowȱtemperatureȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱ temperatureȱdetectorȱ LossȱofȱACȱpowerȱfromȱtheȱmainȱpanelȱ ACȱpowerȱrestoreȱonȱmainȱpanelȱ Lowȱbatteryȱfaultȱrestoreȱfromȱtheȱmainȱpanelȱ Lowȱbatteryȱfaultȱfromȱtheȱmainȱpanelȱ TamperȱalarmȱfromȱtheȱListenȱInȱmessageȱboxȱunitȱ TamperȱalarmȱrestoreȱfromȱtheȱListenȱInȱmessageȱboxȱunitȱ CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱIPȱcardȱ CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱI/Oȱ moduleȱ CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱsounderȱYȱ NoȱcommunicationȱbetweenȱtheȱGSM/GPRSȱModuleȱandȱ theȱAgilityȱ Boxȱ+ȱBellȱtamperȱisȱomittedȱ SystemȱfaultsȱwereȱomittedȱbyȱuserȱXXȱ Zoneȱno.ȱXXȱisȱomittedȱ PartitionȱYȱpartȱsetȱbyȱuserȱZZȱ PartitionȱYȱpartȱsetȱbyȱremoteȱcontrolȱZZȱ PanicȱalarmȱfromȱwirelessȱkeypadȱYȱȱ PanicȱalarmȱfromȱremoteȱcontrolȱYYȱ LoadȱnewȱparametersȱintoȱtheȱAgilityȱfromȱPTMȱaccessoryȱȱ RadioȱlowȱbatteryȱfaultȱfromȱsounderȱYȱ RadioȱlowȱbatteryȱrestoreȱfromȱsounderȱYȱ Theȱsystemȱhasȱbeenȱsetȱfromȱtheȱconfigurationȱsoftwareȱ TheȱsystemȱhasȱbeenȱsetȱinȱPartȱSetȱmodeȱfromȱtheȱ configurationȱsoftwareȱ Theȱsystemȱhasȱbeenȱprogrammedȱfromȱtheȱconfigurationȱ softwareȱ PartitionȱYȱunsetȱfromȱtheȱconfigurationȱsoftwareȱ Alarmȱrestoreȱinȱzoneȱno.ȱXXȱ Wirelessȱreceiverȱjammingȱ TheȱAgilityȱreceivedȱaȱsignalȱfromȱsounderȱYȱafterȱitȱhasȱ beenȱregardedȱasȱlostȱ ZoneȱXXȱhasȱfailedȱinȱtheȱsoakȱtestȱ SounderȱYȱisȱregardedȱasȱlostȱfollowingȱsupervisionȱtestȱ SpecialȱalarmȱfromȱtheȱfromȱwirelessȱkeypadȱYȱȱ Page B-4 AgilityȱEngineerȱManualȱ ȱ EventȱMessageȱ Spkrȱl.batȱrsS=yȱ SpkrȱlowȱbatȱS=yȱ StartȱexitȱP=yȱȱȱ TamperȱI/OȱMdl.ȱȱ TamperȱI/OȱMdl.ȱȱȱ Descriptionȱ SpeakerȱlowȱbatteryȱrestoreȱfromȱsounderȱYȱ SpeakerȱlowȱbatteryȱfaultȱfromȱsounderȱYȱ ExitȱtimeȱstartedȱinȱpartitionȱYȱ TamperȱalarmȱfromȱI/Oȱmoduleȱ TamperȱalarmȱrestoredȱfromȱI/Oȱmoduleȱ TamperȱKeypad=yȱȱ TamperȱrsȱZn=xxȱȱ TamperȱrstȱKP=yȱȱ TamperȱSounder=yȱȱȱ TamperȱZone=xxȱȱȱ TechȱalarmȱZn=xxȱ TechȱrstrȱȱZn=xxȱ TmpȱrstrȱSndr=yȱ UnȬOmitȱZone=xxȱ UnOmtȱBox+Bellȱ Unknownȱeventȱȱȱȱ Unset:P=yȱC=zz Unset:ȱP=yȱKF=zz UserȱloginȱC=xxȱȱ TamperȱalarmȱfromȱkeypadȱID=Yȱ Tamperȱalarmȱrestoreȱonȱzoneȱno.ȱXXȱ KeypadȱYȱtamperȱrestoreȱ TamperȱalarmȱfromȱwirelessȱsounderȱYȱ Tamperȱalarmȱfromȱzoneȱno.ȱXXȱ AlarmȱfromȱzoneȱXXȱdefinedȱasȱTechnicalȱ AlarmȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱTechnicalȱ TamperȱalarmȱrestoreȱfromȱwirelessȱsounderȱYȱ Zoneȱno.ȱXXȱisȱreinstatedȱfromȱomitȱ Boxȱ+ȱBellȱreinstatedȱfromȱomitȱ Unknownȱeventȱalertȱ PartitionȱYȱunsetȱbyȱuserȱZZȱ PartitionȱYȱunsetȱbyȱremoteȱcontrolȱZZȱ UserȱXXȱhasȱenteredȱintoȱprogrammingȱmode.ȱUserȱ99ȱ representsȱremoteȱprogrammingȱfromȱtheȱconfigurationȱ softwareȱ Floodȱalarmȱfromȱzoneȱno.ȱXXȱ Floodȱalarmȱrestoreȱonȱzoneȱno.ȱXXȱ ZoneȱselfȬtestȱfailed,ȱzoneȱno.ȱXXȱ ZoneȱselfȬtestȱOK,ȱzoneȱno.ȱXXȱ ZoneȱfaultȱeventȱfromȱzoneȱXXȱ ZoneȱfaultȱeventȱrestoreȱfromȱzoneȱXXȱ WaterȱAlrmȱZn=xxȱ WaterȱrstrȱZn=xxȱ Z=xxȱautoȱbadȱȱȱȱ Z=xxȱautoȱokȱȱȱȱȱ Zn=xxȱFaultȱ Zn=xxȱFaultȱOKȱ ȱ Page B-5 ȱ AgilityȱEngineerȱManualȱ ȱ Appendix C Library Voice Messages 001ȱ 002ȱ 003ȱ 004ȱ 005ȱ Aȱ 006ȱ 007ȱ 008ȱ 009ȱ 010ȱ 011ȱ 012ȱ 013ȱ 014ȱ Bȱ 015ȱ 016ȱ 017ȱ 018ȱ 019ȱ 020ȱ 021ȱ 022ȱ 023ȱ 024ȱ 025ȱ 026ȱ 027ȱ 028ȱ 029ȱ 030ȱ Cȱ 031ȱ 032ȱ 033ȱ 034ȱ 035ȱ 036ȱ Customȱ Customȱ Customȱ Customȱ Customȱ ȱ Aȱ Aboveȱȱ Airȱconditionerȱ Anȱ Andȱ Apartmentȱ Areaȱ Atȱ Atticȱ ȱ Babyȇsȱroomȱ Backȱ Baggageȱ Balconyȱ Barȱ Barnȱ Basementȱ Bathroomȱ Bedroomȱ Beforeȱ Behindȱ Bottomȱ Boyȇsȱroomȱ Branchȱ Buildingȱ Byȱ ȱ Cabinetȱ Cafeȱ Cameraȱ Canteenȱ Ceilingȱ Cellarȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 037ȱ 038ȱ 039ȱ 040ȱ 041ȱ 042ȱ 043ȱ 044ȱ 045ȱ 046ȱ 047ȱ 048ȱ 049ȱ Dȱ 050ȱ 051ȱ 052ȱ 053ȱ 054ȱ 055ȱ 056ȱ 057ȱ 058ȱ Eȱ 059ȱ 060ȱ 061ȱ 062ȱ 063ȱ 064ȱ 065ȱ 066ȱ 067ȱ 068ȱ Fȱ 069ȱ 070ȱ 071ȱ 072ȱ CentralȱHeatingȱ Childrenȱ Classroomȱ Cleanerȱ COȱ Computerȱroomȱ Conferenceȱ Conservatoryȱ Contactȱ Containerȱ Controlȱ Cornerȱ Curtainȱ ȱ Deskȱ Detectorȱ Deviceȱ Diningȱ Doorȱ Downȱ Downstairsȱ Dressingȱ Driveȱ ȱ Eastȱ Elementȱ Emergencyȱ Engineȱ Entranceȱ Entryȱ Escapeȱ Executiveȱ Exitȱ Externalȱ ȱ Familyȱ Fenceȱ Fireȱ Firstȱ ȱ Page C-1 ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 073ȱ 074ȱ 075ȱ 076ȱ 077ȱ 078ȱ Gȱ 079ȱ 080ȱ 081ȱ 082ȱ 083ȱ 084ȱ 085ȱ 086ȱ 087ȱ 088ȱ 089ȱ 090ȱ Hȱ 091ȱ 092ȱ 093ȱ 094ȱ 095ȱ Iȱ 096ȱ 097ȱ 098ȱ 099ȱ 100ȱ 101ȱ Kȱ 102ȱ Lȱ 103ȱ 104ȱ 105ȱ 106ȱ Floodȱ Floorȱ Forȱ Foyerȱ Freezerȱ Frontȱ ȱ Gamesȱ Garageȱ Gardenȱ Gasȱ Gateȱ Gentsȱ Girlȇsȱroomȱ Glassȱ Groceryȱ Groundȱ Guestȱ Gymȱ ȱ Hallȱ Hallwayȱ Hangerȱ Highȱ Houseȱ ȱ Inȱ Indoorȱ Insideȱ Interiorȱ Internalȱ Isȱ ȱ Kitchenȱ ȱ Labȱ Ladiesȱ Landingȱ Laundryȱ ȱ AgilityȱEngineerȱManualȱ ȱ 107ȱ 108ȱ 109ȱ 110ȱ 111ȱ 112ȱ 113ȱ 114ȱ Mȱ 115ȱ 116ȱ 117ȱ 118ȱ 119ȱ 120ȱ 121ȱ 122ȱ 123ȱ Nȱ 124ȱ 125ȱ 126ȱ 127ȱ Oȱ 128ȱ 129ȱ 130ȱ 131ȱ 132ȱ 133ȱ 134ȱ Pȱ 135ȱ 136ȱ 137ȱ 138ȱ 139ȱ Lavatoryȱ Leftȱ Libraryȱ Liftȱ Lightȱ Livingȱ Lobbyȱ Lowȱ ȱ Machineȱ Macroȱ Magnetȱ Maidȇsȱroomȱ Mainȱ Masterȱ Medicalȱ Middleȱ Motionȱ ȱ Nearȱ Newȱ Northȱ Nurseryȱ ȱ Ofȱ Officeȱ Onȱ Outbuildingȱ Outdoorȱ Outputȱ Outsideȱ ȱ Panicȱ Partitionȱ Passageȱ Patioȱ Perimeterȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 140ȱ 141ȱ Rȱ 142ȱ 143ȱ 144ȱ 145ȱ 146ȱ 147ȱ 148ȱ 149ȱ Sȱ 150ȱ 151ȱ 152ȱ 153ȱ 154ȱ 155ȱ 156ȱ 157ȱ 158ȱ 159ȱ 160ȱ 161ȱ 162ȱ 163ȱ 164ȱ 165ȱ 166ȱ 167ȱ Tȱ 168ȱ 169ȱ 170ȱ 171ȱ 172ȱ 173ȱ Poolȱ Porchȱ ȱ Rearȱ Receptionȱ Refrigeratorȱ Relayȱ Restaurantȱ Rightȱ Roofȱ Roomȱ ȱ Safeȱ Safetyȱ Secondȱ Shedȱ Shockȱ Shopȱ Shutterȱ Sideȱ Siteȱ Smokeȱ Southȱ Spaceȱ Sprinklerȱ Stairsȱ Storeȱ Studentȱroomȱ Studyȱ Suiteȱ ȱ Technicalȱ Temperatureȱ Thirdȱ Toȱ Topȱ TVȱ ȱ Page C-2 ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Uȱ ȱ 174ȱ Underȱ 175ȱ Upȱ 176ȱ Upstairsȱ 177ȱ Utilityȱ Vȱ ȱ 178ȱ Vestibuleȱ 179ȱ Videoȱcameraȱ Wȱ ȱ 180ȱ Wallȱ 181ȱ Warehouseȱ 182ȱ Washroomȱ 183ȱ Westȱ 184ȱ Windowȱ Yȱ ȱ 185ȱ Yardȱ Zȱ ȱ ȱ 186ȱ Zoneȱ ȱȱȱȱȱNumbersȱ ȱ 187ȱ 0ȱ ȱ 188ȱ 1ȱ ȱ 189ȱ 2ȱ ȱ 190ȱ 3ȱ ȱ 191ȱ 4ȱ ȱ 192ȱ 5ȱ ȱ 193ȱ 6ȱ ȱ 194ȱ 7ȱ ȱ 195ȱ 8ȱ ȱ 196ȱ 9ȱ ȱ 197ȱ 10ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ AgilityȱEngineerȱManualȱ ȱ Appendix D EN 50131 Compliance Compliance Statement Hereby,ȱRISCOȱGroupȱdeclaresȱthatȱtheȱAgilityȱseriesȱofȱcentralȱunitsȱandȱaccessoriesȱareȱ designedȱtoȱcomplyȱwith:ȱ EN50131Ȭ1,ȱEN50131Ȭ3ȱGradeȱ2ȱ EN50130Ȭ5ȱEnvironmentalȱclassȱIIȱȱ EN50131Ȭ6ȱTypeȱAȱ UK:ȱDD243:2004,ȱPDȱ6662:2004,ȱACPOȱ(Police)ȱ USA:ȱFCC:ȱPartȱ15B,ȱFCCȱpartȱ68ȱȱ CANADA:ȱCSȬ03,ȱDCȬ01ȱ Possible logical keys calculations: LogicalȱcodesȱareȱcodesȱenteredȱatȱtheȱwirelessȱkeypadȱtoȱallowȱLevelȱ2ȱ(users)ȱandȱ Levelȱ3ȱ(engineer)ȱaccess.ȱ Allȱcodeȱlengthsȱareȱ4ȱdigitsȱlongȱ 0Ȭ9ȱcanȱbeȱusedȱforȱeachȱdigit.ȱ ThereȱareȱnoȱdisallowedȱcodesȱȬȱcodesȱfromȱ0001ȱtoȱ9999ȱareȱacceptable.ȱ Invalidȱcodesȱcannotȱbeȱcreatedȱdueȱtoȱtheȱfactȱthatȱafterȱtheȱcodeȱ4thȱdigitȱhasȱbeenȱ pressed,ȱȈEnterȈȱisȱautomaticallyȱapplied.ȱCodeȱisȱrejectedȱwhenȱtryingȱtoȱcreateȱaȱ nonȱexistingȱcode.ȱ Possible physical keys calculations: PhysicalȱkeysȱareȱimplementedȱinȱtheȱWirelessȱKeyfobs.ȱ ItȱisȱassumedȱthatȱonlyȱaȱuserȱpossessesȱaȱKeyfobs,ȱthereforeȱaȱphysicalȱkeyȱisȱ consideredȱasȱaccessȱLevelȱ2ȱ EachȱKeyfobȱhasȱ24ȱbitȱidentificationȱcodeȱcomprisingȱ2^24ȱoptions.ȱ AȱKeyfobȱhasȱtoȱbeȱrecognizedȱandȱregisteredȱbyȱtheȱAgility,ȱtherefore,ȱaȱȈwriteȈȱ processȱmustȱbeȱperformed.ȱȱ AȱvalidȱKeyfobȱisȱoneȱȈLearnedȈȱbyȱtheȱpanelȱandȱallowingȱSet/Unsetȱ AȱnonȱvalidȱKeyfobȱisȱoneȱnotȱȈLearnedȈȱbyȱtheȱpanelȱandȱnotȱallowingȱSet/Unset.ȱ System Monitoring TheȱmainȱunitȱisȱmonitoredȱforȱACȱfault,ȱbatteryȱfault,ȱlowȱbatteryȱandȱmore.ȱȱ TheȱI/OȱWirelessȱExpanderȱisȱmonitoredȱforȱACȱfault,ȱbatteryȱfault,ȱlowȱbatteryȱandȱ more.ȱ Allȱotherȱwirelessȱelementsȱareȱmonitoredȱforȱlowȱvoltageȱbattery. Page D-1 ȱ AgilityȱEngineerȱManualȱ ȱ Setting the Agility to comply with EN 50131 requirements 1. 2. 3. 4. 5. AccessȱtheȱEngineerȱprogrammingȱmode.ȱ Fromȱtheȱ[1]ȱSystemȱmenuȱselectȱ[5]ȱtoȱaccessȱtheȱSettingsȱmenu.ȱ FromȱtheȱSettingsȱmenuȱselectȱ[4]ȱtoȱaccessȱtheȱStandardȱoption.ȱȱ Defaultȱoption.ȱ SelectȱENȱ50131.ȱOnceȱselected,ȱtheȱfollowingȱchangesȱwillȱoccurȱinȱtheȱAgilityȱsoftware:ȱ Report Codes Feature EN 50131 Compliance Timersȱȱȱ ȱ ȱ PhoneȱLineȱcutȱdelayȱ Immediateȱ(0ȱminutes)ȱ EntryȱDelayȱ 45ȱsecondsȱ(maximumȱallowed)ȱ ACȱDelayȱ Immediateȱ(0ȱminutes)ȱ JammingȱTimeȱ 0ȱminutesȱ RXȱSupervisionȱ 2ȱhoursȱ SystemȱControlsȱȱȱ ȱ ȱ QuickȱSetȱ SetȱtoȱNOȱ ȱ FalseȱCodeȱFaultȱ SetȱtoȱYesȱ ȱ ForcedȱSettingȱ SetȱtoȱNOȱ ȱ AuthorizeȱEngineerȱ SetȱtoȱYESȱ ȱ OverrideȱFaultȱ SetȱtoȱNOȱ ȱ RestoreȱAlarmȱ SetȱtoȱYESȱ ȱ MandatoryȱEventȱLogȱ SetȱtoȱYESȱ ȱ RestoreȱFaultȱ SetȱtoȱYESȱ ȱ ExitȱAlarmȱ SetȱtoȱNOȱ ȱ 20ȱMinutesȱSignalȱ SetȱtoȱYESȱ ȱ EntryȱDelayedȱAlarmȱ SetȱtoȱNOȱ ȱ Attenuationȱ SetȱtoȱYESȱ ȱ ȱ Page D-2 AgilityȱEngineerȱManualȱ ȱ Appendix E Installer Programming Maps 1)ȱProgrammingȱ 2)ȱTestingȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 3)ȱActivitiesȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 4)ȱFollowȱMeȱ ȱ ȱ 5)ȱClockȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 6)ȱEventȱLogȱ 7)ȱMacroȱ SeeȱprogrammingȱmenuȱonȱpageȱEȬ2.ȱ ȱ ȱ 1)ȱMainȱUnitȱ ȱ ȱ 1)ȱNoiseȱLevelȱ ȱ 2)ȱSounderȱ ȱ 3)ȱSpeakerȱ 2)ȱZoneȱ ȱ ȱ 1)ȱCommunicationȱTestȱ ȱ 2)ȱBatteryȱTestȱ 3)ȱKeyfobȱ ȱ ȱ 1)ȱCommunicationȱTestȱ ȱ 2)ȱBatteryȱTestȱ ȱ 3)ȱVersionȱ 4)ȱKeypadȱ ȱ ȱ 1)ȱCommunicationȱTestȱ ȱ 2)ȱBatteryȱTestȱ ȱ 3)ȱVersionȱ 5)ȱSounderȱ ȱ ȱ 1)ȱCommunicationȱTestȱ ȱ 2)ȱBatteryȱTestȱ ȱ 3)ȱSoundȱTestȱ 6)ȱGSMȱ ȱ ȱ 1)ȱSignalȱ ȱ 2)ȱVersionȱ ȱ 3)ȱIMEIȱ 7)ȱIPȱUnitȱ ȱ ȱ 1)ȱIPȱAddressȱ ȱ 2)ȱVersionȱ ȱ 3)ȱMACȱaddressȱ 8)ȱI/OȱModuleȱ ȱ ȱ 1)ȱCommunicationȱTestȱ ȱ 2)ȱBatteryȱTestȱ ȱ 3)ȱVersionȱ ȱ ȱ 1)ȱMainȱBuzzerȱOn/Offȱȱ ȱ 2)ȱKPȱSleepȱTimeȱ ȱ 3)ȱSounderȱTMPȱMuteȱ ȱ 4)ȱAvoidȱReportȱProgȱ ȱ 5)ȱOmitȱBoxȱTamperȱ ȱ 6)ȱEngineerȱResetȱ ȱ 7)ȱCSȱConnectȱ ȱ 8)ȱFirmwareȱUpdateȱ ȱ ȱ ȱ 1)ȱDefineȱ ȱ 2)ȱTestȱFollowȱMeȱ ȱ ȱ ȱ 1)ȱTimeȱandȱDateȱ ȱ 2)ȱSchedulerȱȱ ȱ 3)ȱAuto.ȱClockȱ ȱ ȱ 1)ȱServerȱ ȱ ȱ ȱ ȱ ȱ 2)ȱHostȱ ȱ 3)ȱPortȱ ȱ 4)ȱTimeȱZoneȱ ȱ ȱ ȱ ȱ Page E-1 ȱ ȱ ȱ 4)ȱBatteryȱ 5)ȱVersionȱ 6)ȱSerialȱNumberȱ ȱ 3)ȱWalkȱTestȱ 4)ȱVersionȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 4)ȱNoiseȱLevelȱ 5)ȱVersionȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Daytimeȱ NTPȱ ȱ ȱ ȱ ȱ ȱ ȱ AgilityȱEngineerȱManualȱ ȱ ȱ ȱ ȱ InstallerȱProgrammingȱmenu:ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱSystemȱ ȱ ȱ ȱ ȱ ȱ 1)ȱTimersȱ ȱ ȱ ȱ ȱ 1)ȱEx/EnȱDelayȱ1ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱEntryȱDelayȱ1ȱ ȱ ȱ ȱ ȱ 2)ȱExitȱDelayȱ1ȱ ȱ ȱ ȱ 2)ȱEx/EnȱDelayȱ2ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱEntryȱDelayȱ2ȱ ȱ ȱ ȱ ȱ 2)ȱExitȱDelayȱ2ȱ ȱ ȱ ȱ 3)ȱBellȱTimeoutȱ ȱ ȱ ȱ ȱ 4)ȱBellȱDelayȱ ȱ ȱ ȱ ȱ 5)ȱACȱOffȱDelayȱ ȱ ȱ ȱ ȱ 6)ȱJammingȱTimeȱ ȱ ȱ ȱ ȱ 7)ȱRXȱSuperviseȱ ȱ ȱ ȱ ȱ 8)ȱTXȱSuperviseȱ ȱ ȱ ȱ ȱ 9)ȱRedialȱWaitȱ ȱ ȱ ȱ ȱ 0)ȱMoreȱ ȱ ȱ ȱ ȱ ȱ 1)ȱSwingerȱlimitȱ ȱ ȱ ȱ ȱ 2)ȱNoȱActivityȱ ȱ ȱ ȱ ȱ 3)ȱLastȱExitȱSoundȱ ȱ ȱ 2)ȱControlsȱ ȱ ȱ ȱ ȱ ȱ 1)ȱBasicȱȱ ȱ ȱ ȱ ȱ ȱ QuickȱSetȱ ȱ ȱ ȱ ȱ AllowȱOmitȱ ȱ ȱ ȱ ȱ QuickȱStatusȱ ȱ ȱ ȱ ȱ FalseȱCodeȱFaultȱ ȱ ȱ ȱ ȱ SounderȱSquawkȱ ȱ ȱ ȱ ȱ AudibleȱPanicȱ ȱ ȱ ȱ ȱ BuzzerȱÆȱBellȱ ȱ ȱ ȱ ȱ AudibleȱJammingȱ ȱ ȱ ȱ ȱ ExitȱPartȱSetȱBeepȱ ȱ ȱ ȱ ȱ ForcedȱSettingȱ ȱ SetȱPreȬWarningȱ ȱ ȱ ȱ ȱ DefaultȱEnableȱ ȱ ȱ ȱ ȱ MainȱBut:ȱStatus/Talkȱ ȱ ȱ ȱ ȱ QuickȱLearnȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱAdvancedȱȱ ȱ ȱ ȱ ȱ Areaȱ ȱ ȱ ȱ ȱ ȱ GlobalȱFollowerȱ ȱ ȱ ȱ Summer/Winterȱ ȱ ȱ ȱ ȱ 24ȱHourȱOmitȱ ȱ ȱ ȱ ȱ TamperȱResetȱ ȱ ȱ ȱ ȱ EngineerȱResetȱ ȱ ȱ ȱ ȱ EngineerȱTamperȱ ȱ ȱ ȱ ȱ LowȱBatteryȱSetȱ ȱ ȱ ȱ ȱ SounderȱPreȬalarmȱ ȱ ȱ ȱ ȱ Bellȱ30/10ȱ ȱ ȱ ȱ ȱ FireȱPatternȱ ȱ ȱ Page E-2 AgilityȱEngineerȱManualȱ ȱ ȱ ȱ ȱ IMQȱ ȱ ȱ ȱ DisableȱIncomingȱCallȱ ȱ ȱ ȱ ȱ ȱ ARCȱEnableȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 3)ȱCommunicationȱ ȱ ȱ ȱ ȱ 4)ȱENȱ50131ȱ ȱ ȱ ȱ ConfigurationȱSoftwareȱEnableȱ FMȱEnableȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ AuthorizeȱEngineerȱ ȱ ȱ ȱ OverrideȱFaultȱ ȱ ȱ ȱ RestoreȱAlarmȱ ȱ ȱ ȱ ȱ MandatoryȱEventsȱ ȱ ȱ ȱ ȱ RestoreȱFaultȱ ȱ ȱ ȱ ȱ ExitȱAlarmȱ ȱ ȱ ȱ ȱ EntryȱAlarmȱ ȱ ȱ ȱ ȱ 20ȱMinutesȱSignalȱ ȱ ȱ ȱ ȱ Attenuationȱ ȱ ȱ ȱ ȱ ȱ ȱ 5)ȱDD243ȱȱ ȱ ȱ OmitȱExit/Entryȱ ȱ ȱ ȱ ȱ EntryȱDisableȱ ȱ ȱ ȱ ȱ RouteȱDisableȱ ȱ ȱ ȱ ȱ EngineerȱConfirmationȱ ȱ ȱ ȱ ȱ KeyswitchȱLockȱ ȱ ȱ ȱ ȱ EntryȱUnsetȱ ȱ ȱ ȱ 6)ȱCPȬ01ȱ ȱ ȱ ȱ ȱ ȱ ExitȱRestartȱ ȱ ȱ ȱ ȱ AutoȱPartȱSetȱ ȱ ȱ ȱ ȱ ExitȱErrorȱ ȱ ȱ ȱ ȱ 3ȱMinutesȱOmitȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱSystemȱ ȱ ȱ ȱ ȱ 2)ȱPartitionȱ1ȱ ȱ ȱ ȱ ȱ 3)ȱPartitionȱ2ȱ ȱ ȱ ȱ ȱ 4)ȱPartitionȱ3ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱTamperȱSoundȱ ȱ ȱ ȱ ȱ Silentȱ ȱ ȱ 3)ȱLabelsȱ 4)ȱSoundsȱ ȱ ȱ ȱ ȱ Bellȱ ȱ ȱ ȱ ȱ Buzzerȱ(main)ȱ ȱ ȱ ȱ ȱ Bellȱ+ȱBuzzerȱ ȱ ȱ ȱ ȱ Bell/Setȱ+ȱBuzzer/Unsetȱ ȱ ȱ ȱ ȱ Bell/Setȱ+ȱSil/Unsetȱ ȱ ȱ ȱ ȱ 2)ȱLocalȱAlarmȱ ȱ ȱ ȱ 3)ȱLocalȱSquawkȱ ȱ ȱ ȱ ȱ 4)ȱEx/EnȱBeepsȱȱ ȱ ȱ ȱ ȱ 5)ȱSpeakerȱVolumeȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 5)ȱSettingsȱ ȱ 1)ȱDefaultȱPanelȱ ȱ ȱ ȱ 2)ȱEraseȱWLȱDeviceȱ ȱ ȱ ȱ ȱ 3)ȱLanguageȱ ȱ ȱ ȱ Page E-3 AgilityȱEngineerȱManualȱ ȱ ȱ 4)ȱStandardȱ ȱ ȱ ȱ ȱ ȱ ENȱ50131ȱ ȱ ȱ ȱ ȱ DD243ȱ ȱ ȱ ȱ ȱ CPȬ01ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱServiceȱNameȱ ȱ ȱ ȱ 2)ȱPhoneȱ ȱ 6)ȱServiceȱInfoȱ ȱ ȱ 7)ȱFirmwareȱUpdateȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱServerȱIPȱ ȱ ȱ ȱ ȱ 2)ȱServerȱPortȱ ȱ ȱ ȱ 3)ȱFileȱPathȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱRFȱAllocationȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱByȱSerialȱcodeȱ ȱ ȱ ȱ 3)ȱZoneȱAllocationȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱRadioȱDevicesȱ 1)ȱAllocationȱ ȱ ȱ ȱ 2)ȱModificationȱ ȱ 1)ȱZonesȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱParametersȱ ȱ ȱ ȱ ȱ 1)ȱLabelȱ ȱ 2)ȱSerialȱNo.ȱ ȱ ȱ ȱ ȱ 3)ȱPartitionȱ ȱ ȱ ȱ ȱ 4)ȱTypeȱ ȱ ȱ ȱ ȱ 5)ȱSoundȱ ȱ ȱ ȱ ȱ 6)ȱAdvancedȱȱ ȱ ȱ ȱ ȱ 1)ȱChimeȱ ȱ ȱ ȱ 2)ȱControlsȱ ȱ ȱ ȱ Supervisionȱ ȱ ȱ ȱ ForcedȱSettingȱȱ ȱ ȱ ȱ NoȱActivityȱ ȱ ȱ ȱ AbortȱAlarmȱ ȱ ȱ ȱ LEDȱEnableȱȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 3)ȱSoakȱTestȱ ȱ ȱ ȱ ȱ 4)ȱZoneȱPairingȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱParametersȱ ȱ ȱ ȱ ȱ ȱ 2)ȱKeyfobsȱ ȱ ȱ ȱ ȱ 2)ȱAlarmȱConfirmationȱ 3)ȱDetectionȱModeȱ 4)ȱSensitivityȱȱ ȱ ȱ 1)ȱConfirmȱPartitionȱ ȱ 2)ȱConfirmȱZonesȱ ȱ ȱ ȱ 1ȬWayȱKeyfobȱ 2ȬWayȱKeyfobȱ 1)ȱLabelȱ 1)ȱLabelȱ ȱ ȱ ȱ 2)ȱSerialȱNo.ȱ 2)ȱSerialȱNo.ȱ ȱ ȱ ȱ 3)ȱPartitionȱ 3)ȱPartitionȱ ȱ ȱ ȱ 4)ȱButtonȱ1ȱ 4)ȱPINȱCodeȱ ȱ ȱ ȱ 5)ȱButtonȱ2ȱ 5)ȱPanicȱEnableȱ ȱ ȱ ȱ 6)ȱButtonȱ3ȱ 6)ȱPOȱButtonȱ1ȱ ȱ ȱ ȱ 7)ȱButtonȱ4ȱ 7)ȱPOȱButtonȱ2ȱ ȱ ȱ ȱ ȱ 8)ȱPOȱButtonȱ3ȱ Page E-4 AgilityȱEngineerȱManualȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ InstantȱF.ȱSetȱ ȱ ȱ ȱ ȱ InstantȱP.ȱSetȱ ȱ ȱ ȱ ȱ Unsetȱ+ȱCodeȱ ȱ 3)ȱParentȱControlȱ ȱ ȱ ȱ ȱ ȱ 1)ȱParametersȱ ȱ 1)ȱLabelȱ ȱ 2)ȱSerialȱNo.ȱ ȱ ȱ ȱ ȱ 3)ȱKeypadsȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱControlsȱ ȱ 3)ȱEmergencyȱKeysȱ ȱ ȱ ȱ 4)ȱFunctionȱKeyȱ ȱ ȱ ȱ ȱ 5)ȱOutputȱControlȱ ȱ ȱ ȱ 2)ȱControlsȱ ȱ ȱ ȱ ȱ ȱ RFȱWakeȬupȱ ȱ ȱ ȱ ȱ ȱ ȱ 4)ȱSoundersȱ ȱ 1)ȱLabelȱ ȱ ȱ ȱ ȱ 2)ȱSerialȱNumberȱ ȱ ȱ ȱ ȱ 3)ȱPartitionȱ ȱ ȱ ȱ ȱ 4)ȱSupervisionȱ ȱ ȱ ȱ ȱ 5)ȱVolumeȱ ȱ ȱ ȱ ȱ ȱ 1)ȱAlarmȱ ȱ ȱ ȱ ȱ 2)ȱSquawkȱ ȱ ȱ ȱ ȱ 3)ȱExitȱEntryȱȱ ȱ ȱ ȱ 6)ȱStrobeȱ(Ext.l)ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱStrobeȱCtrlȱȱ ȱ ȱ ȱ ȱ 2)ȱStrobeȱBlinkȱ ȱ ȱ ȱ ȱ 3)ȱStrobeȱatȱSetȱȱ ȱ ȱ 5)ȱI/OȱModulesȱ ȱ ȱ ȱ ȱ ȱ 1)ȱWiredȱZonesȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱLabelȱ ȱ 2)ȱPartitionȱ ȱ ȱ ȱ ȱ 3)ȱTypeȱ ȱ ȱ ȱ ȱ 4)ȱSoundȱ ȱ ȱ ȱ ȱ 5)ȱAdvancedȱȱ ȱ ȱ ȱ ȱ 1)ȱChimeȱ ȱ ȱ ȱ 2)ȱControlȱ ȱ ȱ ȱ 3)ȱTerminationȱ ȱ ȱ ȱ 4)ȱLoopȱResponseȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱOutputsȱ ȱ 5)ȱDetectionȱModeȱ ȱ ȱ 1)ȱLabelȱ ȱ ȱ ȱ ȱ ȱ 2)ȱTypeȱ ȱ ȱ ȱ 3)ȱPatternȱ ȱ ȱ ȱ ȱ 4)ȱPulseȱLengthȱ ȱ ȱ ȱ ȱ ȱ 3)ȱXȬ10ȱOutputsȱ ȱ ȱ ȱ 1)ȱLabelȱ ȱ ȱ ȱ ȱ ȱ 2)ȱTypeȱ ȱ ȱ ȱ 3)ȱPatternȱ ȱ ȱ ȱ ȱ 4)ȱPulseȱLengthȱ ȱ ȱ ȱ ȱ ȱ 4)ȱParametersȱ Page E-5 AgilityȱEngineerȱManualȱ ȱ ȱ ȱ ȱ 1)ȱSerialȱNo.ȱ ȱ ȱ ȱ ȱ 2)ȱControlȱ ȱ ȱ ȱ ȱ ȱ 1)ȱSupervisionȱ ȱ ȱ ȱ ȱ 2)ȱQuickȱPO/X10ȱ ȱ ȱ ȱ 3)ȱX10ȱHouseȱIDȱ ȱ ȱ ȱ ȱ 4)ȱPOȱDTMFȱControlȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱLabelȱ ȱ ȱ ȱ ȱ 2)ȱPartitionȱ ȱ ȱ ȱ ȱ 3)ȱAuthorityȱȱ ȱ ȱ ȱ 3)ȱIdentificationȱ 3)ȱCodesȱ 1)ȱUserȱ ȱ ȱ ȱ Userȱ ȱ ȱ ȱ ȱ Cleanerȱ ȱ ȱ ȱ ȱ SetȱOnlyȱ ȱ ȱ ȱ ȱ Duressȱ ȱ ȱ 2)ȱGrandȱMasterȱ ȱ ȱ ȱ ȱ 3)ȱEngineerȱ ȱ ȱ ȱ ȱ 4)ȱSubȬEngineerȱ ȱ ȱ ȱ ȱ 5)ȱCodeȱLengthȱ ȱ ȱ ȱ ȱ ȱ 4ȱDigitsȱ ȱ ȱ ȱ ȱ 6ȱDigitsȱ ȱ ȱ ȱ 6)ȱDTMFȱCodeȱ ȱ ȱ ȱ ȱ 7)ȱParentȱControlȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 4)ȱCommunicationȱ 1)ȱMethodȱ ȱ 1)ȱPSTNȱ ȱ ȱ ȱ ȱ ȱ 1)ȱTimersȱ ȱ ȱ ȱ ȱ ȱ 1)ȱPSTNȱLostȱDelayȱ ȱ ȱ ȱ 2)ȱWaitȱforȱDialȱToneȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ AlarmȱLineȱCutȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱControlsȱ ȱ 3)ȱParametersȱ ȱ AnswerȱMachineȱOverrideȱ ȱ ȱ 1)ȱRingsȱtoȱAnswerȱ ȱ ȱ ȱ ȱ 2)ȱAreaȱCodeȱ ȱ ȱ ȱ ȱ 3)ȱPBXȱPrefixȱ ȱ ȱ ȱ ȱ ȱ 1)ȱGSMȱLostȱ 2)ȱSIMȱExpireȱ 3)ȱARCȱPollingȱ ȱ 1)ȱAPNȱCodeȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱAPNȱUserȱNameȱ 3)ȱAPNȱPasswordȱ ȱ 1)ȱMailȱHostȱ 2)ȱSMTPȱPortȱ 3)ȱEȬmailȱAddressȱ 4)ȱSMTPȱUserȱNameȱ ȱ ȱ ȱ ȱ ȱ ȱ 5)ȱSMTPȱPasswordȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱGSMȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱTimersȱ ȱ ȱ ȱ 2)ȱGPRSȱ ȱ ȱ ȱ 3)ȱEmailȱ ȱ ȱ ȱ ȱ ȱ Page E-6 AgilityȱEngineerȱManualȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 3)ȱGSMȱRSSIȱ ȱ ȱ ȱ ȱ 4)ȱSIMȱNumberȱ ȱ ȱ ȱ 6)ȱPreȬPaidȱSIMȱ ȱ ȱ ȱ ȱ ȱ 1)ȱGetȱCreditȱbyȱ ȱ ȱ ȱ ȱ 2)SMSȱReceiveȱPhoneȱ 4)ȱControlsȱ ȱ 5)ȱParametersȱ ȱ ȱ ȱ CallerȱIDȱ ȱ ȱ ȱ 1)ȱSIMȱPINȱCodeȱ ȱ 2)ȱSMSȱCenterȱPhoneȱ ȱ 3)ȱIPȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱIPȱConfigurationȱ ȱ 1)ȱObtainȱAutoȱIPȱ ȱ ȱ ȱ ȱ 2)ȱPanelȱIPȱ ȱ ȱ ȱ ȱ 3)ȱSubnetȱMaskȱ ȱ ȱ ȱ ȱ 4)ȱGatewayȱ ȱ ȱ ȱ ȱ 5)ȱDNSȱPrimaryȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱEȬmailȱ 6)ȱDNSȱSecondaryȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱMailȱHostȱ ȱ ȱ ȱ ȱ 2)ȱSMTPȱPortȱ ȱ ȱ ȱ ȱ 3)ȱEȬmailȱAddressȱ ȱ ȱ ȱ ȱ 4)ȱSMTPȱNameȱ ȱ ȱ ȱ ȱ 5)ȱSMTPȱPasswordȱ ȱ ȱ ȱ 3)ȱHostȱNameȱ ȱ ȱ ȱ ȱ 4)ȱARCȱPollingȱ ȱ ȱ ȱ ȱ ȱ 1)ȱPrimaryȱ ȱ ȱ ȱ ȱ 2)ȱSecondaryȱ ȱ ȱ ȱ ȱ 3)ȱBackupȱ ȱ ȱ 5)ȱControlsȱ ȱ ȱ ȱ ȱ DisableȱIPȱ ȱ ȱ ȱ 2)ȱAlarmȱReceivingȱȱ ȱȱȱȱȱȱȱȱCenterȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱReportȱTypeȱ ȱ ȱ ȱ ȱ Voiceȱ ȱ ȱ ȱ ȱ SMSȱ ȱ ȱ ȱ ȱ IPȱ ȱ ȱ ȱ 2)ȱAccountsȱ ȱ ȱ ȱ ȱ 3)ȱCommȱFormatȱ ȱ ȱ ȱ ȱ ContactȱIDȱ ȱ ȱ SIAȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 4)ȱControlsȱ ȱ ȱ Handshakeȱ ȱ ȱ ȱ ȱ KissȬOffȱ ȱ ȱ ȱ ȱ ȱ 1)ȱARCȱRetriesȱ ȱ ȱ 2)ȱAlarmȱRestoreȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 5)ȱParametersȱ ȱ ȱ 6)ȱARCȱTimersȱ ȱ 1)ȱPeriodicȱTestȱ ȱ ȱ ȱ 2)ȱAbortȱAlarmȱ ȱ ȱ ȱ ȱ 3)ȱCancelȱDelayȱ ȱ ȱ Page E-7 AgilityȱEngineerȱManualȱ ȱ ȱ ȱ 4)ȱListenȱInȱ ȱ ȱ ȱ 5)ȱConfirmationȱ ȱ ȱ ȱ ȱ 6)ȱNoȱSetȱ ȱ ȱ ȱ ȱ 7)ȱReportȱSplitȱ ȱ ȱ ȱ ȱ ȱ 1)ȱARCȱSet/Unsetȱ ȱ ȱ ȱ ȱ 2)ȱARCȱUrgentȱ ȱ ȱ ȱ ȱ 3)ȱARCȱNonȱUrgentȱ ȱ ȱ ȱ 8)ȱReportȱCodesȱ ȱ ȱ ȱ ȱ ȱ 1)ȱEditȱCodesȱ ȱ ȱ ȱ ȱ 2)ȱDeleteȱAllȱ ȱ ȱ 3)ȱConfigurationȱs/wȱ ȱ ȱ ȱ ȱ ȱ 1)ȱSecurityȱ ȱ ȱ ȱ ȱ 1)ȱAccessȱcodeȱ ȱ ȱ ȱ ȱ 2)ȱRemoteȱIDȱ ȱ ȱ ȱ ȱ 3)ȱARCȱLockȱ ȱ ȱ ȱ ȱ ȱ 4)ȱFollowȬMeȱ ȱ ȱ 2)ȱCallȱBackȱ 3)ȱConfigȱSWȱPortȱ(IPȱ Gateway)ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱDefineȱFMȱ ȱ ȱ ȱ ȱ 1)ȱReportȱtypeȱ ȱ ȱ ȱ Voiceȱȱ ȱ ȱ ȱ ȱ ȱ ȱ SMSȱ ȱ ȱ ȱ ȱ Emailȱ ȱ ȱ ȱ ȱ 2)ȱEventsȱ ȱ ȱ ȱ 3)ȱRestoreȱeventsȱ ȱ ȱ ȱ ȱ 4)ȱRemoteȱcontrolȱ ȱ ȱ ȱ ȱ ȱ ȱ Remoteȱlistenȱ ȱ ȱ ȱ Remoteȱprogramȱ ȱ ȱ ȱ 5)ȱPartitionȱ ȱ ȱ ȱ ȱ ȱ UnsetȱstopȱFMȱ ȱ ȱ 3)ȱParametersȱ ȱ ȱ ȱ ȱ 2)ȱControlsȱ ȱ ȱ ȱ ȱ ȱ 1)ȱFMȱRetriesȱ ȱ ȱ ȱ ȱ 2)ȱVoiceȱMesgȱReccur.ȱ ȱ ȱ ȱ ȱ 3)ȱPeriodicȱtestȱ ȱ ȱ 5)ȱAudioȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 1)ȱAssignȱMessageȱ ȱ 1)ȱZoneȱ ȱ ȱ ȱ 2)ȱPartitionȱ ȱ ȱ ȱ ȱ 3)ȱOutputȱ ȱ ȱ ȱ ȱ 4)ȱX10ȱoutputȱ ȱ ȱ ȱ ȱ 5)ȱMacroȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ 2)ȱLocalȱMessageȱ 0)ȱExitȱ Page E-8 Notes ȱ Notes ȱ RISCO Group Limited Warranty RISCOȱGroupȱandȱitsȱsubsidiariesȱandȱaffiliatesȱ(ȈSellerȈ)ȱwarrantsȱitsȱproductsȱtoȱbeȱfreeȱ fromȱdefectsȱinȱmaterialsȱandȱworkmanshipȱunderȱnormalȱuseȱforȱ24ȱmonthsȱfromȱtheȱdateȱ ofȱproduction.ȱBecauseȱSellerȱdoesȱnotȱinstallȱorȱconnectȱtheȱproductȱandȱbecauseȱtheȱ productȱmayȱbeȱusedȱinȱconjunctionȱwithȱproductsȱnotȱmanufacturedȱbyȱtheȱSeller,ȱSellerȱ cannotȱguaranteeȱtheȱperformanceȱofȱtheȱsecurityȱsystemȱwhichȱusesȱthisȱproduct.ȱSellerȇsȱ obligationȱandȱliabilityȱunderȱthisȱwarrantyȱisȱexpresslyȱlimitedȱtoȱrepairingȱandȱreplacing,ȱ atȱSellerȇsȱoption,ȱwithinȱaȱreasonableȱtimeȱafterȱtheȱdateȱofȱdelivery,ȱanyȱproductȱnotȱ meetingȱtheȱspecifications.ȱSellerȱmakesȱnoȱotherȱwarranty,ȱexpressedȱorȱimplied,ȱandȱ makesȱnoȱwarrantyȱofȱmerchantabilityȱorȱofȱfitnessȱforȱanyȱparticularȱpurpose.ȱ Inȱnoȱcaseȱshallȱsellerȱbeȱliableȱforȱanyȱconsequentialȱorȱincidentalȱdamagesȱforȱbreachȱofȱ thisȱorȱanyȱotherȱwarranty,ȱexpressedȱorȱimplied,ȱorȱuponȱanyȱotherȱbasisȱofȱliabilityȱ whatsoever.ȱ Sellerȇsȱobligationȱunderȱthisȱwarrantyȱshallȱnotȱincludeȱanyȱtransportationȱchargesȱorȱcostsȱ ofȱinstallationȱorȱanyȱliabilityȱforȱdirect,ȱindirect,ȱorȱconsequentialȱdamagesȱorȱdelay.ȱ Sellerȱdoesȱnotȱrepresentȱthatȱitsȱproductȱmayȱnotȱbeȱcompromisedȱorȱcircumvented;ȱthatȱ theȱproductȱwillȱpreventȱanyȱpersonalȱinjuryȱorȱpropertyȱlossȱbyȱburglary,ȱrobbery,ȱfireȱorȱ otherwise;ȱorȱthatȱtheȱproductȱwillȱinȱallȱcasesȱprovideȱadequateȱwarningȱorȱprotection.ȱ Buyerȱunderstandsȱthatȱaȱproperlyȱinstalledȱandȱmaintainedȱalarmȱmayȱonlyȱreduceȱtheȱriskȱ ofȱburglary,ȱrobberyȱorȱfireȱwithoutȱwarning,ȱbutȱisȱnotȱinsuranceȱorȱaȱguarantyȱthatȱsuchȱ eventȱwillȱnotȱoccurȱorȱthatȱthereȱwillȱbeȱnoȱpersonalȱinjuryȱorȱpropertyȱlossȱasȱaȱresultȱ thereof.ȱ Consequentlyȱsellerȱshallȱhaveȱnoȱliabilityȱforȱanyȱpersonalȱinjury,ȱpropertyȱdamageȱorȱlossȱ basedȱonȱaȱclaimȱthatȱtheȱproductȱfailsȱtoȱgiveȱwarning.ȱHowever,ȱifȱsellerȱisȱheldȱliable,ȱ whetherȱdirectlyȱorȱindirectly,ȱforȱanyȱlossȱorȱdamageȱarisingȱunderȱthisȱlimitedȱwarrantyȱorȱ otherwise,ȱregardlessȱofȱcauseȱorȱorigin,ȱsellerȇsȱmaximumȱliabilityȱshallȱnotȱexceedȱtheȱ purchaseȱpriceȱofȱtheȱproduct,ȱwhichȱshallȱbeȱcompleteȱandȱexclusiveȱremedyȱagainstȱseller.ȱ NoȱemployeeȱorȱrepresentativeȱofȱSellerȱisȱauthorizedȱtoȱchangeȱthisȱwarrantyȱinȱanyȱwayȱ orȱgrantȱanyȱotherȱwarranty.ȱ WARNING:ȱThisȱproductȱshouldȱbeȱtestedȱatȱleastȱonceȱaȱweek.ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Contacting RISCO Group RISCOȱGroupȱisȱcommittedȱtoȱcustomerȱserviceȱandȱproductȱsupport.ȱYouȱcanȱcontactȱusȱ throughȱourȱwebsiteȱwww.riscogroup.comȱorȱasȱfollows:ȱ ȱ UnitedȱKingdomȱ USAȱ Tel:ȱ+44Ȭ161Ȭ655Ȭ5500 Tel:ȱ+1Ȭ631Ȭ719Ȭ4400ȱ [email protected]ȱ supportȬ[email protected]ȱ Italyȱ Tel:ȱ+39Ȭ02Ȭ66590054 [email protected]ȱ Brazilȱ Tel:ȱ+55Ȭ11Ȭ3661Ȭ8767ȱ supportȬ[email protected]ȱ Spainȱ Tel:ȱ+34Ȭ91Ȭ490Ȭ2133 supportȬ[email protected]ȱ Chinaȱ Tel:ȱ+86Ȭ21Ȭ52Ȭ39Ȭ0066ȱ supportȬ[email protected]ȱ Franceȱ Tel:ȱ+33Ȭ164Ȭ73Ȭ28Ȭ50 supportȬ[email protected]ȱ Polandȱ Tel:ȱ+48Ȭ22Ȭ500Ȭ28Ȭ40ȱ supportȬ[email protected]ȱ Belgiumȱ Tel:ȱ+32Ȭ2522Ȭ7622 supportȬ[email protected]ȱ Israelȱ Tel:ȱ+972Ȭ3Ȭ963Ȭ7777 [email protected]ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Allȱrightsȱreserved.ȱȱ Noȱpartȱofȱthisȱdocumentȱmayȱbeȱreproducedȱinȱanyȱformȱwithoutȱpriorȱwrittenȱ permissionȱfromȱtheȱpublisher.ȱ ȱ ȱ ©ȱRISCOȱGroupȱȱȱ03/10ȱȱ ȱȱ ȱ ȱ ȱ ȱȱȱȱȱȱȱȱȱȱȱȱȱȱ5IN1081ȱBȱ ȱ
advertisement
Key Features
- 32 wireless zones
- 3 partitions
- up to 3 bi-directional wireless keypads
- up to 8 remote control keyfobs
- compatible with RISCO Group’s extensive range of wireless security and safety devices
- flexible communication options
- easy programming
- remote management
- home automation capabilities