Equinox Systems EQLED49 User manual

Equinox Systems EQLED49 User manual

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Equinox Systems EQLED49 User manual | Manualzz

Equinox Triclops Beam

Order code: EQLED49

User Manual

Contents

1. Safety Instructions

2. Features & Specifications

3. How To Set The Unit

4. How To Control The Unit

5. Troubleshooting

6. Fixture Cleaning

1. Safety Instruction

Please read the instructions carefully as they include important

WARNING information about installation, usage and maintenance.

Please keep this User Guide for future consultation. If you sell the unit to another user be sure that they also receive this.

Unpack and check carefully that there is no transportation damage before using the unit.

Ÿ Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the unit.

Ÿ It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.

Ÿ The unit is for indoor use only. Use only in a dry location.

Ÿ The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.

Ÿ Disconnect the mains power before replacement or servicing.

Ÿ Make sure there are no flammable materials close to the unit while operating as they may cause a fire hazard.

Ÿ Always use a safety cable when installing this unit. Do not carry the unit by its head only, always carry it using the base.

Ÿ The maximum ambient temperature is to: 40 degrees C. Don’t operate it where the temperature is higher than this.

Ÿ In the event of a serious operating problem stop using the unit immediately.

Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.

Ÿ Do not touch any power cables during operation as the high voltage may cause an electric shock.

Warning

Ÿ To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.

Do not open the unit within five minutes after switching off.

Ÿ The housing and lenses must be replaced if they are visibly damaged.

Installation

The unit should be mounted via its screw holes onto the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Make sure that the structure to which you are attaching the unit to is secure and is able to support a weight of 10 times of the unit’s weight. Always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture.

The equipment must be installed by professionals and it must be installed in a place where is out of the reach of people and no one can pass by or under it.

Power sockets:

XLR sockets:

2. Features & Technical Specifications

Control: Sound active, auto, Master/slave and DMX 512 modes

DMX Channels: 1 and 8

Electronic dimming: 0-100%

Electronic strobe with pulse and random effects

High output with low power consumption

Compact size and low weight

Voltage:

Fuse:

Power consumption:

100V~240V, 50/60Hz

T3A 250V

85W

15 x 3W RGBWA LED Light source:

Dimensions:

Weight:

345 x 385 x 235mm

3.9kg

IEC in/out

3-pin XLR in/out

3. How To Set The Unit

3.1 Control panel

Display

Shows the various menus and selected functions

Button

MENU Selects the programming functions

DOWN To go backward in the selected functions

UP To go forward in the selected functions

ENTER Confirms the selected functions

Mains input

Connection to the power supply.

DMX input/output

For DMX 512 linking. Use 3-pin XLR cables to link to the controller or to other units.

3.2 Main Functions

To select any of the given functions, press the MODE button up to where the required function is showing on the display. Select the function by pressing the

ENTER button and the display will blink. Use the DOWN and UP buttons to change the mode. Once the required mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes, press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

The main functions are as below:

ADDR

CHAN MODE

SLND

001-512

1, 8

SL1

SL2

Menu

SHND

SOUN

SENS

LED

DISP→DSIP INVERT

TEST

HOURS

VER

REST

NAST

SH1

SH2

SH3

SH4

ON

OFF

0-100

ON

OFF

DMX Address Setting

Press the MODE button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to choose the address from 1-255. Once the address has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Slave Mode

Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (normal) or

(2 light show) or for master mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Show Mode

Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (show 1) or

(show 2) or (show 3) or (show 4) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Sound Mode

Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (sound on) or

(sound off) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Sound sensitivity

Press the MENU button to select . Press the ENTER button and use the

DOWN and UP buttons to select the sound sensitivity (0-100).

Led Display

Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (Led display on) or

(Led display off) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the

MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Display Inversion

Press the MENU button to select mode

. Press the ENTER button to change to the

(display normal), It will be automatically saved after 8 seconds. Press the ENTER button again to select the mode (display inversion). To go back to the functions press the MENU button. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Display normal mode is for floor standing the unit.

Display inversion mode is for hanging the unit from a ceiling.

Auto-Test

Press the MENU button to select . Press the ENTER button and the unit will run a self-test with its built-in programs. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Reset

Press the MENU button to select . Press the ENTER button and all channels of the unit will return to their standard position.

4. How To Control The Unit

1. Master/slave built-in preprogram function

2. Universal DMX controller

There is no need to turn the unit off when you change the DMX address as new DMX address setting will be affected at once. Every time you turn the unit on, it will show

on the display and move all the motors to their ‘home’ position and you may hear some noises for about 20 seconds. After that the unit will be ready to receive DMX signal or run the built in programs.

4.1 Master/Slave Built In Preprogrammed Function

By linking the units in master/slave connection, the first unit will control the other units to give an automatic, sound activated, synchronized light show. This function is good when you want an instant show. You have to set the first unit as master and select show 1, show 2, show 3 or show 4 from the Show Mode. The other units must be set to either Slave 1 (normal) or Slave 2 (2 light show) mode. A DMX cable between the units for daisy chaining is needed.

2-light show

In slave mode, Slave 1 means the unit works normally and Slave 2 means 2-light show. In order to create a great light show, you can set Slave 2 on the second unit to get contrast movement to each other, even if you have two units only.

4.2 DMX Controller

By using a universal DMX controller to control the units, you will need to set a DMX address from 1 to 512 so that the units can receive a DMX signal.

Press the MENU button until is showing on the display. Press the ENTER button and the display will blink. Use the DOWN and UP buttons to change the

DMX-512 address. Once the address has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button one second or wait for one minute to go back to the main menu.

Please refer to the below diagram to address your first 4 units :

Channel mode

Unit 1

Address

Unit 2

Address

Unit 3

Address

Unit 4

Address

8 channels 1

4.3 DMX 512 Configuration

1 channel DMX chart

Channel

CH1

Value

000-007

008-037

038-067

068-097

098-127

128-157

158-187

188-217

218-247

248-255

9 17 25

Function

Blackout

Show 1

Show 2

Show 3

Show 4

Show 5

Show 6

Show 7

Show 8

Random show 1-8

Sound activated

8 channel DMX chart

Channel Value

CH1

CH2

CH3

000-255

000-008

009-255

000-255

000-008

CH4

(The first head, LED colour selection)

CH5

CH6

CH7

CH8

009-016

017-024

025-032

033-040

041-048

049-056

057-064

065-072

073-080

081-088

089-096

097-104

105-112

113-120

121-128

000-255

000-008

009-255

000-255

000-008

009-255

Function

Full dimmer, 0-100%

No function

B

W

A

R+G

R+A

G+B

B+W

B+A

Strobe, slow to fast

The first head, Y position

No function

R

G

R+B

R+W

G+W

G+A

129-136

137-144

145-152

153-160

161-168

169-176

177-184

185-192

193-200

201-208

209-216

217-224

225-232

233-240

241-248

R+G+B

R+G+W

R+G+A

R+B+W

R+B+A

R+W+A

G+B+W

G+B+A

G+W+A

B+W+A

R+G+B+W

R+G+W+A

R+G+B+A

R+B+W+A

G+B+W+A

W+A 249-255 R+B+A+W+A

The second head, Y position

No function

The second head, LED colour selection

The third head, Y position

No function

The third head, LED colour selection

4.4 DMX512 CONNECTION

1. In the last unit, the DMX has to be terminated with a termination plug. Solder a 120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin

XLR-plug and plug it in the DMX-output of the last unit.

2. Connect the units together in a `daisy chain` with an XLR plug from the output of the unit to the input of the next unit. The cable can not be branched or split to a `Y` cable.

3. The DMX output and input connectors are a pass-through type to maintain the

DMX circuit when one of the units’ power is disconnected.

4. Each lighting unit needs to have an address setup to receive the data sent by the controller. The address number is between 0-512

5. The end of the DMX 512 system should be terminated to reduce signal errors.

6. 3 pin XLR cable wiring configuration

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)

5.Troubleshooting

Following are a few common problems that may occur during operation and some suggestions for easy troubleshooting:

A. The unit does not work, no light and the fan does not work

1. Check the connection of the power and the main fuse.

B. Not responding to DMX controller

1. If the DMX address is showing but no response to the controller, check the address settings and DMX polarity.

2. Try another DMX controller.

C. No response to the sound

1. Make sure the unit is not receiving a DMX signal.

2. Check the microphone to see if it is good by tapping it. The microphone is located on the bottom plate of the unit.

6. Fixture Cleaning

The cleaning of external optical lenses must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause a greater accumulation of dirt on the unit’s optics.

Clean with a soft cloth using normal glass cleaning fluid or mild soapy water.

Ÿ Always dry the parts carefully.

Ÿ Clean the external optics at least every 20 days.

www.prolight.co.uk

advertisement