Below you will find brief information for Multimeter C1000 C1000, Multimeter C1090 C1090, Multimeter C2000 C2000. This manual explains how to install and operate the device, including detailed instructions on measuring DC voltage and current, AC voltage, resistance, and output measurements. The manual also includes a schematic diagram for each model.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Tsurumi Trading Company Multimeter C1000, C1090, C2000 User Manual | Manualzz
1,0000 MINITESTER |
NY F4,
- ”
AC VOLTS: !
Plug in the test leads, black lead in “ —com” jack and red lead into “ +V mA"
jack. Select the proper AC voltage range with the range selector switch and
read directly on the corresponding AC voltage on the meter scale.
DC VOLT AND CURRENT:
Plug in the test leads, black lead in “ —com” jack and red lead into “ +V mA”
jack. Select the proper DC voltage on current range with the range selector
switch and read directly on the corresponding meter scale.
OHMS:
Plug in the test leads, black lead in “ —com” jack and red lead into * +
com” jack. Before measuring, check zero ohms indication by shorting the tips
of test leads together. If needle does not indicate zero ohms, adjust the zero
adjust control on the left side of the meter cabinet.
с a
ALY ZA Dev À
E Ten = Es Se — es -
бов Е а ae 3. => 1 5 2 зв Не
1,000. MINITESTER
SCHEMATIC: DIA
OPERATING INSTRUCTIONS
4,0000 MINITESTER
INSTALLING BATTERY:
Remove the back cover and insert the equivalent 1.5V penlight battery. Careful-
ly observe polarity and make certain that the battery is firmly seated.
SPECIAL NOTES:
1. TTC model employs a highly precision meter movement and extreme .
mechanical shock should be avoided.
2. Carefully observe polarity of test leads when measuring voltage or current.
3. When measuring an unknown voltage or current, select the highest range
first then work down to a suitable range for best reading.
4. The control on the left side of the cabinet is the zero adjust control for
ohms measurement.
5. When using the ohms range and needle will not zero properly by shorting
tips of test leads together, replace the battery. |
= NEED . TEE
вв = Den a RS AG RE
I МА VAL | |
COM Rect 4 wave VIA + —CCH Rect A wave V-DA + — COM Rect 4 Wave VIA +
КТ 9.55K RS 21K R1 9.55K RS ZIK R1 18.4K R5 5.6K
RZ 730K R 6 5.460 R2 750K R6 5.460 R2 1M R6 120
R3 200K R 7 5360 R3 200K R7 5360 R3 900K R7 12K
R4 40K V.R. 7000 Ка 40K V.R. 7000 R4 80K V.R. 1.68K
C1000 C1090 C2000
10,000 OHMS/VOLT MULTITESTER
with test leads compartment
BATTERY INSTALLATION:
Remove the back cover from your multitester and insert “AA” size battery
into the bracket provided. Carefully observe polarity and be sure that the
battery is firmly seated with proper contact on each end.
ar
NOTE for C1050:
Remove the red wire (being set on a printed circuit board on the zero
ohm adjust knob) which is shorted directly across the two termi -
nal screws on the back of the meter movement. This wire is placed
here at the time of manufacture to prevent damage in transport-
ation. This wire must be removed before your test will operate.
DC VOLTAGE AND CURRENT:
a) Insert the black test lead into the ( —) COM jack and the red test lead
in into the ( +) jack.
b) Select the desired range by turning the range selector knob.
с) For voltage measurements, the test leads are connected across the
load under test. DC current measurements are made with the test
leads connected in series with the circuit under test.
Observe proper polarities of the test leads carefully.
d) If the vollage or the current of*the circuit under test is not known,
the selector knob should be set at a high range and lowered scale at
a time to obtain satisfactory readings. To measure DC voltage in the
1200V range, insert the black lead into the (—) jack and the red lead
in the { +) 1.2KV DC jack setting the selector to 600 + 1.2K position.
AC VOLTAGE AND DECIBELS:
a) Insert the black test lead into the ( —) jack the red test lead into
20,000 OHMS/VOLT MULTITESTER
with leather case
c Curent. =
i -Decibel
the ( +) jack.
b) Select the range by turning the knob to the "ACV" section.
c) Decibel measurements for audio circuits are made with the test leads
in the same position. The inner decibel scale is graduated from —20
to +17 dB for 6V AC range and calibrated for 0 dB level of 1 milli -
watt on a 600 ohm line.
d) The polarity of the leads is not important.
RESISTANCE MEASUREMENTS:
a) Inseet the test leads into the ( —) and the ( +) jacks.
b) Select the range by turning the knob to x10 or xI1K.
c) Make SHORTING TEST before making measurements. Check the ZERO
ohm setting by shorting the test leads and adjusting the 0 ohm adjust
knob. The pointer is to be adjusted to “0" on the OHM scale.
d) Connect the leads across the resistor under test and read the top
scale by applying the proper multiplier, 10 or 1000.
e) When making resistance measurements of components wired in circuit,
be certain that the circuit power is turned off and also that one end
of the resistor or device under test is disconnected from the circuit.
f) Renew the internal battery when the SHORTING TEST fails to bring
the pointer to “0” on the OHMS scale.
OUTPUT MEASUREMENTS:
a) Audio output measurements can be made on circuits where DC is
present as in the output transformer circuits.
This instrument contains a blocking capacitor in series with OUTPUT
jack .
b) Insert the test leads into the OUTPUT and the ( —) jacks.
c) The output voltages are reads on the AC voltage ranges.
SCHEMATIC DIAGRAMS
R1 27.89K
RZ 120K
R3 1.35M
Rá 4.5M
RS 6M
R6 45
A7 11.25K
RE 2.25K
R9 2K
R10 135
RITO MK
R12 B.6K
! Rect. 1/2 Wave
y. VR 5K (B)
с 0.05 uF
1200 300 30 6 300m 120u 3 15 150 600 x10 xiK
BD uk
acy — pcal EC y N
RI 96K
| RECT. Ve WAVE
R2 400K
[R3 2m
| R4 7.5M
AS 3.68
RE 364.32
R7 18.032K
RE 2.BK
RS 290
R10 2.8K
с R11 21K
EE R12 SK VA
S OUT © pisse R13 20K
E
R14 10M
с 0.05 uF
M 40 uA
A LL
= 8 v Se
ACY E Eo Y L
Copyright 1971 — Tsurumi Trading Company Ltd. — Printed in Japan
|
= ©
50 u
E
u
es
OFF
1000
г’
х 10
x 100
=
L_ x 1k
— -

advertisement

Key Features

  • DC voltage & current measurement
  • AC voltage measurement
  • Resistance measurement
  • Output measurement
  • Zero adjust control
  • High precision meter movement
  • Blocking capacitor
  • Range selector switch
  • Test leads compartment
  • Leather case

Frequently Answers and Questions

How do I measure DC voltage and current?
Plug in the black test lead into the "COM" jack and the red test lead into the "+V mA" jack. Select the proper DC voltage or current range with the range selector switch and read directly on the corresponding meter scale. Observe proper polarities of the test leads carefully.
How do I measure resistance?
Plug in the black test lead into the "COM" jack and the red test lead into the " + COM" jack. Before measuring, check zero ohms indication by shorting the tips of test leads together. If the needle does not indicate zero ohms, adjust the zero adjust control on the left side of the meter cabinet.
What should I do if the needle will not zero properly when measuring resistance?
Replace the battery.
How do I install the battery?
Remove the back cover and insert the equivalent 1.5V penlight battery. Carefully observe polarity and make certain that the battery is firmly seated.

Related manuals

Download PDF

advertisement