YORK® RAC, PAC & VRF 2017 A more comfortable, safe and sustainable world RAC, PAC & VRF Air-conditioning solutions Every market is unique in air-conditioning requirements. In this catalogue our customers will be able to select the different options for residential market and VRF solutions for Light-Commercial market. Johnson Controls wants to offer all the possible solutions for different building design and technical requirements, and the air-conditioning is an important part of those global solutions. MINISPLIT SOLUTIONS • High Wall inverter • Multisplit inverter • Floor/ceiling inverter • Cassette inverter • Blower inverter 4 YORK® AIR-CONDITIONING PRODUCTS The majority of our products are already rated as Class A or more for Energy Efficiency, in order to guarantee lower consumption. According to the market necessities our customers can find the best solution in our wide product range depending on the building characteristics. VRF SOLUTIONS (Outdoor units) • Capacities from 9 to 211 kW • Operating range of nominal power (10% - 130 %) • DC Inverter Scroll Technology • Low noise levels • High performance • Flexible and quickly installation • Heat recovery VRF SOLUTIONS (Indoor units) • High Wall • Cassette • Convertible console floor/ceiling • Console • Blower • Fresh air • Heat recovery 5 Catalogue content Pag. Split Systems High wall Inverter R32 YHKF 09 to 24 ZEEBMHORX 16 High wall Inverter Pyrenees YHKE 09 to 24 ZEEAMHORX 18 High wall Inverter Monte Rosa YHKE 09 to 24 ZE-MJORX 20 Multi Inverter “Free Indoor Units” YJU_YH 14 to 45 22 Floor/Ceiling Inverter YFKE 18 to 55 26 Cassette Inverter YTKE 12 to 18 BZE / YKKE 18 to 55 BZE(O) 28 Blower Inverter Medium Static Pressure YEKE 12 to 55 BZE(O) 30 High Wall On/Off Monte Rosa YHGE 09 to 24 ZE--MJORX 34 Floor/Ceiling On/Off YFGE 12 to 55 BZE(O) 36 Cassette On/Off YTGE 12 to 18 BZE / YKGE 18 to 55 BZE(O) 38 Blower On/Off Medium Static Pressure YEGE 12 to 55 BZE(O) 40 Blower On/Off High Static Pressure YGGE 24 to 55 BZE(O) 42 VRF System High Efficiency YV2VYH 025 to 204 46 Amazon Standard Ambient VRF System YV2V 010 to 135 48 VRF Systems 6 YORK® AIR-CONDITIONING PRODUCTS Cooling capacity kW 1.0 5.0 10.0 20.0 2.7 - 7.3 2.6 - 7.0 2.6 - 7.0 4.1 - 11.8 5.3 - 15.8 3.5 - 16.1 3.5 - 15.8 2.6 - 7.0 3.5 - 16.1 3.5 - 16.1 3.5 - 16.1 5.3 - 16.4 25.4 - 211.2 9 - 135 7 50.0 100.0 200.0 8 YORK® AIR-CONDITIONING PRODUCTS efficiency and ecological inverter range The High Wall inverter air conditioners have been designed thinking about comfort and sustainability. Comfort as the ultimate technology of DC Inverter compressor installed in these units is able to achieve high performances in heating and cooling mode, the temperature variations in the room are minimized and the noise level is lower. Sustainable because the high efficiency of the unit results in a very low energy consumption, one of the most efficient in the market, the materials used are recyclable and free of hazardous substances, all together makes this unit the appropriate choice for conditioning your home. The R32 is the new refrigerant that has a zero impact on the ozone layer and a smaller impact on global warming. We are sure that technology improves people’s lives. This is why we introduce a new generation of air conditioners with R32, an innovative refrigerant in every imaginable way: easy to install, environmentally friendly and energy saving. R32 REFRIGERANT 9 10 YORK® AIR-CONDITIONING PRODUCTS Main Features EU Energy Label A Class Auto-Restart Function With the powerful compressor and optimized refrigerant, the SEER can reach EU Energy Label A Class (over 5.1 w/w) or B Class (over 4.6 w/w), greatly reducing the power consumption. When the power supply is interrupted and then restored, the air conditioners automatically restore the previous function setting. Turbo Mode WiFi control Press the Turbo button and the A/C will reach the preset temperature in the shortest time. With the WiFi control, you can easly turn off the AC outside your house via smart device. Furthermore, you can turn it on before you come back. Sleep Mode Low Ambient Kit With Spleep Mode, the air conditioner’s set temperature will automatically increase (cooling) or decrease (heating) 1°C per hour for the first two hours then hold steady for the next 5 hours after which the air conditioner will stop operation. With the sleep mode function can maintain the most confortable temperature and save energy. The air conditioning unit can operate in cooling mode at low ambient temperature conditions. The kit is suitable for special applications such as computer and power station control rooms where cooling is required even in the winter months. Dehumidification Anti-Rust Cabinet and Valve Protection Cover Independent dehumidification function is usually used in rainy days in springtime or damps areas. The unit will alternately operate in cooling mode or fan only mode, which assures strong dehumidification while not lowering room temperature. Cabinet made from electrolytic zinc steel sheet and anti-rust coated components. York’s outdoor units are rust free even in coastal regions. The valve protection cover protects the service valves and prevents water from dripping. Iconography Infrared control Wired control Infrared or Wired control Dry mode Sleep mode Timer Auto Sweep Auto Restart Turbo mode Thin profile Quiet 4 Way Air Flow Floor/ Ceiling Ducted Installation Air Filter Low Ambient Kit 11 Range Capacities 2.0 3.0 2.5 High Wall Inverter R32 2.7 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 3.5 5.3 2.6 3.5 5.3 7.0 2.6 3.5 5.3 7.0 7.5 8.0 8.5 9.0 10.0 9.5 7.3 Page 16 High Wall Inverter Pyrenees Page 18 High Wall Inverter Monte Rosa Page 20 4.1 Multi Inverter 5.1 5.3 7.4 8.5 9.7 Page 22 5.3 7.0 8.8 3.5 5.3 7.0 8.8 3.5 5.3 7.0 8.8 3.5 5.3 7.0 3.5 5.3 7.0 3.5 5.3 7.0 3.5 5.3 7.0 Floor/Ceiling Inverter Page 26 Cassette Inverter Page 28 Blower Inverter Page 30 High Wall On/Off Monte Rosa 2.6 Page 34 Floor/Ceiling On/Off Page 36 Cassette On/Off Page 38 Blower On/Off MSP Page 40 7.0 Blower On/Off HSP Page 42 * ErP documents for product below 12kW available in https://virtualbranch.johnsoncontrols.com/vb/catalog/HVAC-Equipment/6/Minisplits/33 12 YORK® AIR-CONDITIONING PRODUCTS 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 11.8 10.6 12.3 10.6 12.3 10.6 12.3 14.1 15.8 13.8 16.1 14.1 15.8 10.6 14.1 16.1 10.6 14.1 16.1 10.6 14.1 16.1 10.6 14.1 16.4 13 17.0 17.5 18.0 18.5 kW 14 YORK® AIR-CONDITIONING PRODUCTS Minisplit Inverter Systems high wall inverter floor/ceiling inverter cassette inverter blower inverter 15 High Wall Inverter YHKF 09 to 24 ZEEBMHORX A complete range from 2.7 kW to 7.3 kW Features Remote controller • R32 Refrigerant • High SEER & SCOP, Class A++ • DC Inverter compressor • Low noise levels • Multispeed fan • Automatic restart • Automatic air sweep • LED display • Two-way draining • High density filter • Low Ambient Kit • Refrigerant leakage detect • Service valve protection cover • Rustproof casing • Blue fin protection (indoor and outdoor units) • Wireless • Follow me function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • 5 Fan speeds selection • Quiet/sleep button • ON/OFF timer • Air flow direction setting • LCD display • Turbo mode • Room temperature setting 16 YORK® AIR-CONDITIONING PRODUCTS High Wall Inverter YHKF 09 to 24 ZEEBMHORX Technical features Set reference YHKF_ZEEBMHORX Indoor unit Sizes YHKF09XEEBMH-RX YHKF12XEEBMH-RX YHKF18XEEBMH-RX YHKF24XEEBMH-RX Outdoor unit Sizes YHKF09YEEBMHO-X YHKF12YEEBMHO-X YHKF18YEEBMHO-X YHKF24YEEBMHO-X Cooling capacity kW 2.7 (1.0~3.2) 3.5 (0.8~4.2) 5.3 (1.7~6.2) 7.3 (2.6~8.4) Heating capacity kW 2.9 (0.9~3.7) 3.8 (0.8~4.8) 5.6 (1.1~7.0) 7.6 (1.5~9.4) Compressor Type Rotary Refrigerant R32 Power supply Power input V/Ph/Hz 230 / 1 / 50 + E cooling kW 0.07 ~ 1.23 0.05 ~ 1.60 0.12 ~ 2.39 0.23 - 3.35 heating kW 0.14 ~ 1.31 0.13 ~ 1.71 0.19 ~ 2.49 0.23 - 3.37 SEER 7.1 7.5 6.7 6.9 SCOP 4.0 4.2 4.0 4.0 cooling A++ A++ A++ A++ heating A+ A+ A+ A+ Energy Class Indoor airflow m3/h 521 / 429 / 259 539 / 478 / 294 750 / 505 / 420 1050 / 750 / 560 Sound pressure Indoor (H/M/L) at 1 m Outdoor dB(A) 37 / 29.5 / 22 38 / 30 / 22 42 / 33 / 27 46 / 40 / 30 dB(A) 55 55 57 59 H (mm) 290 297 319 335 1 080 Indoor Dimensions Outdoor Net weight W (mm) 722 802 965 D (mm) 187 189 215 226 H (mm) 555 555 554 700 W (mm) 770 770 800 845 D (mm) 300 300 333 320 Indoor unit kg 7.4 8.2 9 12 Outdoor unit kg 26.4 26.5 37 48 Gas 3/8” 3/8” 1/2” 5/8” Liquid 1/4” 1/4” 1/4” 3/8” Type of connection Piping Diameter Refrigerant charge Pipe run Flare g 700 800 1 250 1 600 Length m 25 25 30 50 Height m 10 10 20 25 18 24 Operating limit - cooling mode min./max. -15°C / +50°C Operating limit - heating mode min./max. -15°C / +30°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 09 12 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 17 High Wall Inverter Pyrenees YHKE 09 to 24 ZEEAMHORX A complete range from 2.6 kW to 7.0 kW Features Remote controller • High SEER & SCOP, Class A++ • DC Inverter compressor • Low noise levels • Multispeed fan • Automatic restart • Automatic air sweep • LED display • Two-way draining • High density filter • Low Ambient Kit • Refrigerant leakage detect • Service valve protection cover • Rustproof casing • Blue fin protection (indoor and outdoor units) • Wireless • Follow me function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • 5 Fan speeds selection • Quiet/sleep button • ON/OFF timer • Air flow direction setting • LCD display • Turbo mode • Room temperature setting 18 YORK® AIR-CONDITIONING PRODUCTS High Wall Inverter Pyrenees YHKE 09 to 24 ZEEAMHORX Technical features Set reference YHKE_ZEEAMHORX Indoor unit Sizes YHKE09XEEAMH-RX YHKE12XEEAMH-RX YHKE18XEEAMH-RX YHKE24XEEAMH-RX Outdoor unit Sizes YHKE09YEEAMHO-X YHKE12YEEAMHO-X YHKE18YEEAMHO-X YHKE24YEEAMHO-X Cooling capacity kW 2.6 (1.2~3.3) 3.5 (1.4~4.5) 5.3 (1.8~6.2) 7.0 (2.7~8.1) Heating capacity kW 2.9 (0.9~3.8) 3.8 (1.1~4.9) 5.6 (1.4~9.4) 7.9 (2.2~9.3) Compressor Type Rotary Refrigerant R410A Power supply Power input V/Ph/Hz 230 / 1 / 50 + E cooling kW 0.75 (0.09~1.27) 1.13 (0.1~1.74) 1.54 (0.15~2.38) 2.26 (0.23~3.11) heating kW 0.75 (0.14~1.34) 1.06 (0.17~1.76) 1.50 (0.22~2.43) 2.32 (0.32~3.32) SEER 7.4 6.8 6.8 6.6 SCOP 4.2 4.2 4.0 4.0 cooling A++ A++ A++ A++ heating A+ A+ A+ A+ Energy Class Indoor airflow m3/h 420 / 310 / 240 520 / 460 / 270 750 / 500 / 420 1 060 / 830 / 610 Sound pressure Indoor (H/M/L) at 1 m Outdoor dB(A) 37 / 33 / 23 39 / 35 / 24 42 / 34 / 29 48 / 43 / 32 dB(A) 58 60 62 66 H (mm) 290 297 319 335 1 080 Indoor Dimensions Outdoor Net weight W (mm) 722 802 965 D (mm) 187 189 215 226 H (mm) 555 554 554 702 W (mm) 770 800 800 845 D (mm) 300 333 333 363 Indoor unit kg 7.4 8.2 10.7 13 Outdoor unit kg 26.6 29.1 37.8 48.4 Gas 3/8” 3/8” 1/2” 5/8” Liquid 1/4” 1/4” 1/4” 3/8” Type of connection Piping Diameter Refrigerant charge Pipe run Flare g 800 950 1 480 2 000 Length m 25 25 30 50 Height m 10 10 20 25 18 24 Operating limit - cooling mode min./max. -15°C / +50°C Operating limit - heating mode min./max. -15°C / +30°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 09 12 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 19 High Wall Inverter Monte Rosa YHKE 09 to 24 ZE-MJORX A complete range from 2.6 kW to 7.0 kW Features Remote controller • High SEER & SCOP, Class A++ • DC Inverter compressor • Low noise levels • Multispeed fan • Automatic restart • Automatic air sweep • LED display • Two-way draining • High density filter • Low Ambient Kit • Refrigerant leakage detect • Service valve protection cover • Rustproof casing • Blue fin protection (indoor and outdoor units) • Wireless • Follow me function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • 5 Fan speeds selection • Quiet/sleep button • ON/OFF timer • Air flow direction setting • LCD display • Turbo mode • Room temperature setting 20 YORK® AIR-CONDITIONING PRODUCTS High Wall Inverter Monte Rosa YHKE 09 to 24 ZE-MJORX Technical features Set reference YHKE_ZE-MJORX Indoor unit Sizes YHKE09XE-MJ-RX YHKE12XE-MJ-RX YHKE18XE-MJ-RX YHKE24XE-MJ-RX Outdoor unit Sizes YHKE09YE-MJO-X YHKE12YE-MJO-X YHKE18YE-MJO-X YHKE24YE-MJO-X Cooling capacity kW 2.6 (1.0~3.2) 3.5 (1.1~4.1) 5.3 (1.8~6.1) 7.0 (2.7~7.9) Heating capacity kW 2.9 (0.8~3.4) 3.8 (0.9~4.2) 5.6 (1.4~6.7) 7.3 (1.6~8.8) Compressor Type Rotary Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 + E cooling kW 0.1 ~ 1.24 0.1 ~ 1.58 0.14 ~ 2.36 0.24 ~ 3.03 heating kW 0.12 ~ 1.20 0.13 ~ 1.51 0.2 ~ 2.41 0.26 ~ 3.14 SEER 6.2 6.1 6.4 6.1 SCOP 4.0 4.0 4.0 4.0 cooling A++ A++ A++ A++ heating A+ A+ A+ A+ Power input Energy Class Indoor airflow m3/h 420 / 320 / 270 570 / 470 / 370 840 / 680 / 540 980 / 800 / 640 Sound pressure Indoor (H/M/L) at 1 m Outdoor dB(A) 40 / 34 / 29.5 41 / 36 / 28 47 / 40 / 35 45 / 39 / 34 dB(A) 55.5 56 56 60 H (mm) 285 285 302 327 W (mm) 715 805 957 1 040 D (mm) 194 194 213 220 H (mm) 555 555 554 702 Outdoor W (mm) 770 770 800 845 D (mm) 300 300 333 363 Indoor unit kg 6.8 7.2 9.5 11.9 Outdoor unit kg 25.2 25.5 37.8 48.4 Indoor Dimensions Net weight Type of connection Piping Diameter Refrigerant charge Pipe run Flare Gas 3/8” 3/8” 1/2” 5/8” Liquid 1/4” 1/4” 1/4” 3/8” g 800 800 1 480 1 850 Length m 25 25 30 50 Height m 10 10 20 25 18 24 Operating limit - cooling mode min./max. -15°C / +50°C Operating limit - heating mode min./max. -15°C / +30°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 09 12 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 21 Multi Inverter Free Indoor Units YJU_YH 014 to 045 A complete range from 4.1 kW to 11.8 kW Features Remote controller • High SEER & SCOP, Class A or more • DC inverter compressor • Free match indoor/outdoor • Automatic restart • ON/OFF timer • Automatic air sweep • Valve protection cover • Single general valve design (25K/30K/34K) • Blue fin protection (indoor and outdoor units) • Wireless • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • On/Off timer • Turbo cool/heat settings • Fan speed selection • Air flow direction setting • LED display • Lock button Indoor units 22 YORK® AIR-CONDITIONING PRODUCTS Multi Inverter Free Indoor Units YJU_YH 014 to 045 Technical features Outdoor units Model YJU_YH Outdoor units Sizes YJU2YH014 YJU2YH018 YJU3YH019 YJU4YH025 YJU4YH030 YJU5YH034 Indoor units number 2 indoor units 2 indoor units 3 indoor units 4 indoor units 4 indoor units 5 indoor units YJU5YH045 5 indoor units Cooling capacity kW 4.1 (1.2 ~ 4.5) 5.1 (1.3 ~ 5.8) 5.3 (1.5 ~ 7.0) 7.4 (1.5 ~ 9.0) 8.5 (1.5 ~ 9.8) 9.7 (1.5 ~ 11.0) 11.8 (1.5 ~ 13.4) Heating capacity kW 4.4 (1.5 ~ 5.0) 5.8 (1.9 ~ 6.6) 6.3 (1.8 ~ 8.1) 8.3 (1.8 ~ 9.5) 9.5 (1.8 ~ 10.5) 10.3 (1.8 ~ 11.5) 12.2 (1.8 ~ 14.0) Compressor Type (Nb) 2.94 Rotary Inverter (1) Refrigerant R410A Location of expansion device Power supply Outdoor unit V/Ph/Hz 230 / 1 / 50 + E cooling kW 1.17 1.47 1.39 2.10 2.41 2.94 heating kW 1.12 1.41 1.52 2.06 2.43 2.85 2.85 3.9 3.5 3.8 3.5 3.5 3.3 3.09 SEER 5.56 5.59 6.6 6.6 6.6 6.6 6.6 COP 4.03 3.74 4.30 3.80 4.00 3.90 3.80 3.8 4.0 4.0 4.0 4.0 4.0 3.8 A A A++ A++ A++ A++ A++ Power input EER SCOP Energy Class cooling heating Airflow (outdoor unit) m3/h Sound pressure level Dimensions outdoor unit A A+ A+ A+ A+ A+ A 1 900 2 900 2 000 3 500 4 000 4 000 4 200 dB(A) 62 63 52 56 56 58 60 Height mm 540 688 688 840 840 840 830 Width mm 780 810 886 948 948 948 1 008 Depth mm 270 288 289 340 340 340 447 kg 38 43.5 51 74 76 77 90 Net weight outdoor unit Type of connection Piping Max pipe run * Flare Gas 3/8” 3/8” 3 x 3/8” 3 x 3/8” + 1 x 1/2” 3 x 3/8” + 1 x 1/2” 4 x 3/8” + 1 x 1/2” 3 x 3/8” + 2 x 1/2” Liquid 1/4” 1/4” 3 x 1/4” 4 x 1/4” 4 x 1/4” 5 x 1/4” 5 x 1/4” Length m 30 30 50 70 70 80 100 Height m 15 15 15 15 15 15 15 g 1 200 1 400 2 000 3 100 3 200 3 400 3 200 Diameter Refrigerant charge Operating limits cooling mode min/max -10°C / +46°C Operating limits heating mode min/max -15°C / +24°C * values for all the system (all indoor units connected) Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge (each indoor unit) Manufacturer reserves the rights to change specifications without prior notice. 23 Indoor units technical features High Wall Features • Automatic restart • Automatic air sweep Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions Net Weight Piping Sizes 07 * kW 2.0 kW 2.2 V/Ph/Hz m3/h 600 H/M/L dB(A) 38 / 33 / 26 H/W/D mm 280 / 855 / 204 kg 10 Type of connection Gas 3/8” Diameter Liquid 1/4” 09 * 2.7 2.8 600 38 / 33 / 26 280 / 855 / 204 10 3/8” 1/4” YJHMXH 12 3.6 3.7 230 / 1 / 50 + E 650 39 / 34 / 27 280 / 855 / 204 10 Flare 3/8” 1/4” 18 5.2 5.8 24 7.0 7.5 900 44 / 40 / 35 322 / 997 / 235 13 1 200 47 / 43 / 37 336 / 1115 / 248 16 1/2” 1/4” 5/8” 1/4” Floor / Ceiling Features • Floor/Ceiling • Automatic air sweep Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions Net Weight Piping Sizes kW kW V/Ph/Hz m3/h H/M/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid YHFMXH 18 5.0 5.5 230 / 1 / 50 + E 800 44 / 41 / 36 665 / 990 / 199 28.3 Flare 1/2” 1/4” 12 3.5 3.9 650 41 / 37 / 33 665 / 990 / 199 26.3 3/8” 1/4” 24 6.3 7.1 800 48 / 45 / 42 665 / 990 / 199 28.3 5/8” 3/8” Cassette YHKMXH Features • Condensate pump included • Automatic air sweep Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions unit Dimensions panel Net weight Piping Sizes kW kW V/Ph/Hz m3/h H/M/L dB(A) H/W/D mm H/W/D mm kg Type of connection Gas Diameter Liquid 09 * 2.6 2.9 620 40 / 36 / 32 260 / 570 / 570 60 / 700 / 700 17 3/8” 1/4” 12 3.5 3.7 18 5.0 5.2 230 / 1 / 50 + E 620 680 40 / 36 / 32 42 / 37 / 35 260 / 570 / 570 260 / 570 / 570 60 / 700 / 700 60 / 700 / 700 18.5 18.5 Flare 3/8” 1/2” 1/4” 1/4” 24 6.5 7.1 1 300 46 / 44 / 39 240 / 840 / 840 60 / 950 / 950 26.8 5/8” 3/8” Slim duct YH3MXH Features • Slim size • Air filter included • Wired control included Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Static pressure Sound pressure level Dimensions Net Weight Piping Sizes kW kW V/Ph/Hz m3/h Pa H/M/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid 09 * 2.7 2.8 530 30 33 / 29 / 26 185 / 850 / 420 15.9 3/8” 1/4” 12 3.5 3.9 18 5.0 6.4 230 / 1 / 50 + E 600 900 30 30 35 / 31 / 27 36 / 30 / 26 185 / 850 / 420 185 / 1 170 / 420 15.9 25 Flare 3/8” 1/2” 1/4” 1/4” 24 7.1 7.2 1 100 30 39 / 32 / 29 185 / 1 170 / 420 27 5/8” 3/8” Duct YHDMXH Features • Air filter included • Wired control included Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Static pressure Sound pressure level Dimensions Net Weight Piping Sizes kW kW V/Ph/Hz m3/h Pa H/M/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid 09 * 2.5 2.9 550 25 37 / 34 / 31 220 / 610 / 483 14 3/8” 1/4” 24 12 3.5 4.0 18 5.0 5.5 230 / 1 / 50 + E 550 850 25 25 37 / 34 / 31 41 / 35 / 32 220 / 610 / 483 220 / 1 090 / 500 14 23 Flare 3/8” 1/2” 1/4” 1/4” 24 6.8 7.1 1 200 25 45 / 41 / 37 220 / 1 090 / 500 24.5 5/8” 3/8” YORK® AIR-CONDITIONING PRODUCTS Indoor unit combinations YJU2YH014 (2x1) YJU2YH018 (2x1) Number connecting units 2x1 7+7 7+9 7+12 Number connecting units 2x1 9+9 9+12 7+7 7+9 7+12 9+9 9+12 12+12 YJU3YH019 (3x1) Number connecting units 2x1 3x1 7+7 7+9 7+12 7+18 9+9 9+12 9+18 12+12 12+18 7+7+7 7+7+9 7+7+12 7+7+18 7+9+9 7+9+12 7+12+12 9+9+9 9+9+12 9+12+12 YJU4YH025 (4x1) Number connecting units 3x1 2x1 7+18 7+24 9+18 9+24 12+12 12+18 12+24 18+18 18+24 7+7+9 7+7+12 7+7+18 7+7+24 7+9+9 7+9+12 7+9+18 7+12+12 4x1 7+12+18 9+9+9 9+9+12 9+9+18 9+12+12 12+12+12 12+12+18 7+7+7+7 7+7+7+9 7+7+7+12 7+7+7+18 7+7+9+9 7+7+9+12 7+9+9+9 7+9+9+12 9+9+9+9 9+9+9+12 YJU4YH030 (4x1) Number connecting units 3x1 2x1 7+24 9+18 9+24 12+18 12+24 18+18 18+24 24+24 7+7+18 7+7+24 7+9+12 7+9+18 7+9+24 7+12+12 7+12+18 7+12+24 9+9+9 9+9+12 4x1 9+9+18 9+9+24 9+12+12 9+12+18 9+12+24 12+12+12 12+12+18 12+12+24 12+18+18 7+7+7+7 7+7+7+9 7+7+7+12 7+7+7+18 7+7+7+24 7+7+9+9 7+7+9+12 7+7+9+18 7+7+9+24 7+7+12+12 7+7+12+18 7+9+9+9 7+9+9+12 7+9+9+18 7+9+12+12 7+12+12+12 9+9+9+9 9+9+9+12 9+9+12+12 9+9+12+18 9+12+12+12 12+12+12+12 YJU5YH034 (5x1) 2x1 7+18 7+24 9+18 9+24 12+18 12+24 18+18 18+24 24+24 Number connecting units 4x1 3x1 7+7+12 7+7+18 7+7+24 7+9+9 7+9+12 7+9+18 7+9+24 7+12+12 7+12+18 7+12+24 9+9+9 9+9+12 9+9+18 9+9+24 9+12+12 9+12+18 9+12+24 12+12+12 12+12+18 12+12+24 12+18+18 18+18+18 7+7+7+7 7+7+7+9 7+7+7+12 7+7+7+18 7+7+7+24 7+7+9+9 7+7+9+12 7+7+9+18 7+7+9+24 7+7+12+12 7+7+12+18 5x1 7+9+9+9 7+9+9+12 7+9+9+18 7+9+12+12 7+12+12+12 9+9+9+9 9+9+9+12 9+9+9+18 9+9+12+12 9+12+12+12 12+12+12+12 7+7+7+7+7 7+7+7+7+9 7+7+7+7+12 7+7+7+9+9 7+7+7+9+12 7+7+7+12+12 7+7+9+9+9 7+7+9+9+12 7+9+9+9+9 9+9+9+9+9 9+9+9+9+12 9+9+9+12+12 YJU5YH045 (5x1) 2x1 7+18 7+24 9+18 9+24 12+18 12+24 18+18 18+24 24+24 Number connecting units 4x1 3x1 7+7+12 7+7+18 7+7+24 7+9+9 7+9+12 7+9+18 7+9+24 7+12+12 7+12+18 7+12+24 9+9+9 9+9+12 9+9+18 9+9+24 9+12+12 9+12+18 9+12+24 12+12+12 12+12+18 12+12+24 12+18+18 12+18+24 18+18+18 7+7+7+7 7+7+7+9 7+7+7+12 7+7+7+18 7+7+7+24 7+7+9+9 7+7+9+12 7+7+9+18 7+7+9+24 7+7+12+12 7+7+12+18 7+7+12+24 7+9+9+9 7+9+9+12 25 5x1 7+9+9+18 7+9+9+24 7+9+12+12 7+12+12+12 9+9+9+9 9+9+9+12 9+9+9+18 9+9+9+24 9+9+12+12 9+9+12+18 9+12+12+12 9+12+12+18 9+12+12+24 7+7+7+7+7 7+7+7+7+9 7+7+7+7+12 7+7+7+7+24 7+7+7+9+9 7+7+7+9+12 7+7+7+9+18 7+7+7+9+24 7+7+7+12+12 7+7+7+12+18 7+7+7+12+24 7+7+9+9+9 7+7+9+9+12 7+7+9+9+18 7+7+9+9+24 9+9+9+9+9 9+9+9+9+12 9+9+9+9+18 9+9+9+12+12 9+9+9+12+18 Floor/Ceiling Inverter YFKE 18 to 55 A complete range from 5.3 kW to 15.8 kW Features Remote controller • High SEER & SCOP, Class A++ • Inverter DC compressor and fan motor • Washable filter • Convertible - floor or ceiling • Automatic restart • Automatic air sweep • Horizontal and vertical air sweep function • Different swing angle design for cooling and heating • 3D airflow • Low Ambient Kit • Service valve protection cover • Rustproof casing • Self diagnosis • Blue fin protection (indoor and outdoor units) • Wireless • Follow me function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer setting function • Air flow direction setting • LCD display • Turbo mode 26 YORK® AIR-CONDITIONING PRODUCTS Floor/Ceiling Inverter YFKE 18 to 55 Technical features Set reference YFKE_ZEEBMORX Indoor unit Sizes YFKE 18 YFKE 24 YFKE 30 YFKE 36 YFKE 42 YFKE 48 YFKE 55 Outdoor unit Sizes YUKE 18 YUKE 24 YUKE 30 YUKE 36 YUKE 42 YUKE 48 YUKE 55 Cooling capacity kW 5.3 (0.8 - 36.2) 7.0 (1.20 - 8.21) 8.8 (2.1 - 10.6) 10.6 (2.9 - 12.0) 12.3 (3.2 - 13.2) 14.1 (4.1 - 16.4) 15.8 (5.0 - 18.1) Heating capacity kW 5.7 (0.9 - 7.0) 7.0 (1.20 - 8.65) 9.4 (2.1 - 10.8) 11.1 (2.6 - 13.2) 13.5 (3.0 - 14.7) 16.4 (4.4 - 18.5) 18.2 (5.3 - 20.5) Compressor Type Rotary Refrigerant R410A Power supply Power input V/Ph/Hz 230 / 1 / 50 230 / 1 / 50 or 400 / 3 / 50 400 / 3 / 50 cooling kW 1630 (270 - 2365) 2285 (400 - 3155) 2960 (690 - 4055) 4060 (975 - 4620) 4230 (1070 - 5070) 5190 (1370 - 6310) 6060 (1660 - 6965) heating kW 5645 (1760 - 7320) 1460 (255 - 2510) 1900 (400 - 3090) 2475 (690 - 3870) 2985 (880 - 4690) 3540 (945 - 5000) 4810 (1465 - 6590) SEER 6.5 6.1 6.1 6.3 6.1 6.1 6.1 SCOP 4.0 4.0 4.0 4.0 4.0 4.0 4.0 cooling A++ A++ A++ A++ A++ A++ A++ heating A+ A+ A+ A+ A+ A+ A+ m3/h 900 / 800 / 700 1180 / 1050 / 850 1650 / 1450 / 1250 2048 / 1767 / 1403 2271 / 1886 / 1394 2100 / 1800 / 1400 2250 / 1660 / 1280 Indoor (H/M/L) dB(A) 44 / 39 / 34 53 / 48 / 42 54 / 49 / 44 52 / 46 / 40 55 / 49 / 43 52 / 46 / 41 55 / 50 / 45 Outdoor dB(A) 56.5 60.5 59.5 61 62.5 65 62.5 H (mm) 675 675 675 675 675 675 675 W (mm) 1 068 1 068 1 280 1 650 1 650 1 650 1 650 Energy Class Indoor airflow Sound pressure at 1 m Indoor D (mm) 235 235 235 235 235 235 235 H (mm) 554 702 810 810 810 1 333 1 333 W (mm) 800 845 946 946 946 952 952 D (mm) 333 363 410 410 410 410 410 Indoor unit kg 25.8 25 31 40.3 40.5 38.2 40.5 Outdoor unit kg 35.5 49 62.9 67.2 70.5 95.1 112.8 Gas 1/2” 5/8” 5/8” 5/8” 5/8” 5/8” 5/8” Liquid 1/4” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Dimensions Outdoor Net weight Type of connection Piping Pipe run Diameter Flare Length m 30 50 50 65 65 65 65 Height m 20 25 25 30 30 30 30 42 48 55 Operating limits - cooling mode min/max -15°C / +50°C Operating limits - heating mode min/max -15°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Size 36, 42 and 48: Values for single phase models. Accessories Sizes 18 24 30 36 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 27 Cassette Inverter YTKE 12 to 18 BZE / YKKE 18 to 55 BZE(O) A complete range from 3.5 kW to 16.1 kW Features Remote controller • High SEER & SCOP, Class A++ mainly • Inverter DC compressor and fan motor • Special low noise fan design • Washable filter • Fresh air intake • Built-in drain pump • Automatic restart • Automatic air sweep • Low Ambient Kit • Different swing angle design for cooling and heating • Service valve protection cover • Rustproof casing • Self diagnosis • Blue fin protection (indoor and outdoor units) • Wireless • Follow me function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer setting function • Air flow direction setting • LCD display • Turbo mode 28 YORK® AIR-CONDITIONING PRODUCTS Cassette Inverter YTKE 12 to 18 BZE / YKKE 18 to 55 BZE(O) Technical features Set reference YTKE_BZEEBMORX YKKE_BZE(O) Indoor unit Sizes YTKE 12 YTKE 18 YKKE 18 YKKE 24 YKKE 30 YKKE 36 YKKE 42 YKKE 48 YKKE 55 Outdoor unit Sizes YUKE 12 YUKE 18 YUKE 18 YUKE 24 YUKE 30 YUKE 36 YUKE 42 YUKE 48 YUKE 55 Cooling capacity kW 3.5 (0.6~4.4) 5.3 (0.8~6.2) 5.3 (0.8~6.2) 7.0 (1.2~8.2) 8.8 (2.1~10.6) 10.6 (2.9~12.0) 12.3 (3.2~13.2) 13.8 (4.0~16.1) 16.1 (5.0~18.5) Heating capacity kW 4.1 (1.0~5.1) 5.6 (0.9~7.0) 5.7 (0.9~7.0) 7.0 (1.2~8.7) 9.1 (2.1~10.5) 11.1 (2.6~13.2) 13.5 (2.9~14.7) 15.5 (4.2~17.6) 18.2 (5.3~20.5) Compressor Type Rotary Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 230 / 1 / 50 or 400 / 3 / 50 400 / 3 / 50 cooling kW 0.96 1.63 1.68 2.17 2.76 4.06 4.09 5.15 6.39 heating kW 0.99 1.50 1.46 1.90 2.38 3.08 3.53 4.55 5.73 SEER 6.1 6.3 6.3 6.1 6.1 6.1 5.6 5.6 5.6 SCOP 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 cooling A++ A++ A++ A++ A++ A++ A+ A+ A+ heating A+ A+ A+ A+ A+ A+ A+ A+ A+ Power input Energy Class Indoor airflow (H/M/L) m3/h 650/530/450 660/550/490 1000/800/700 Sound pressure Indoor (H/M/L) at 1 m Outdoor dB(A) 42 / 38 / 34 46 / 42 / 38 46 / 41 / 37 46 / 42 / 39 53 / 48 / 44 53 / 50 / 47 54 / 51 / 48 53 / 49 / 45 52 / 49 / 46 dB(A) 57 56.5 56.5 60.5 59.5 61 62.5 65 62.5 H (mm) 260 260 205 257 257 257 287 287 287 W (mm) 570 570 840 840 840 840 840 840 840 Indoor Dimensions Outdoor Net weight 1450/1250/1100 1700/1460/1300 1900/1750/1460 1850/1600/1400 1850/1600/1400 1900/1650/1450 D (mm) 570 570 840 840 840 840 840 840 840 H (mm) 554 554 554 702 810 810 810 1 333 1 333 W (mm) 800 800 800 845 946 946 946 952 952 D (mm) 333 333 333 363 410 410 410 410 410 50 / 647 / 647 50 / 647 / 647 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 Panel H / W / D mm Indoor unit kg 18.5 19 26.3 29 31.5 30.6 31.1 32 36 Outdoor unit kg 34.5 35.5 35.5 49 62.9 67.2 70.5 95.1 112.8 Gas 3/8” 1/2” 1/2” 5/8” 5/8” 5/8” 5/8” 5/8” 5/8” Liquid 1/4” 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Type of connection Piping Pipe run Diameter Flare Length m 25 30 30 50 50 65 65 65 65 Height m 10 20 20 25 25 30 30 30 30 36 42 48 55 Operating limits - cooling mode min/max -15°C / +50°C Operating limits - heating mode min/max -15°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Size 36, 42 and 48: Values for single phase models. Accessories Sizes 12 18 18 24 30 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 29 Blower Inverter Medium Static Pressure YEKE 12 to 55 BZE(O) A complete range from 3.5 kW to 15.8 kW Features Wired control • High SEER & SCOP, Class A+ or more • Inverter DC compressor and fan motor • Washable filter • Automatic restart • Condensate pump optional • Low noise levels • Wired control • Low Ambient Kit • Intelligent defrosting • Fresh air intake • Service valve protection cover • Rustproof casing • Self diagnosis • Blue fin protection (indoor and outdoor units) • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer • LCD display 30 YORK® AIR-CONDITIONING PRODUCTS Blower Inverter Medium Static Pressure YEKE 12 to 55 BZE(O) Technical features Set reference YEKE_BZE(O) Indoor unit Sizes YEKE 12 YEKE 18 YEKE 24 YEKE 30 YEKE 36 YEKE 42 YEKE 48 YEKE 55 Outdoor unit Sizes YUKE 12 YUKE 18 YUKE 24 YUKE 30 YUKE 36 YUKE 42 YUKE 48 YUKE 55 Cooling capacity kW 3.5 (0.6~4.4) 5.3 (0.8~6.2) 7.0 (1.2~8.2) 8.8 (2.1~10.6) 10.6 (2.9~12.0) 12.3 (3.2~13.2) 14.1 (4.1~16.4) 15.8 (5.0~18.1) Heating capacity kW 3.8 (0.6~5.0) 5.7 (0.9~7.0) 7.0 (1.2~8.7) 9.4 (2.1~10.9) 11.1 (2.6~13.2) 13.5 (2.9~14.7) 16.1 (4.3~18.1) 18.2 (5.3~20.5) Compressor Type Rotary Refrigerant R410A Power supply Power input V/Ph/Hz 230 / 1 / 50 230 / 1 / 50 or 400 / 3 / 50 400 / 3 / 50 cooling kW 1.03 1.68 2.28 2.87 3.96 4.09 5.11 5.25 heating kW 0.95 1.46 1.90 2.46 2.92 3.53 4.35 5.03 SEER 6.1 6.5 6.1 6.1 6.3 5.6 6.1 6.1 SCOP 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 cooling A++ A++ A++ A++ A++ A+ A++ A++ heating A+ A+ A+ A+ A+ A+ A+ A+ 680 / 580 / 450 1050 / 900 / 780 Energy Class Indoor airflow m3/h External static pressure Sound pressure at 1 m 0 / 100 0 / 100 0 / 100 0 / 100 0 / 100 0 / 100 0 / 100 44 / 40 / 37 46 / 42 / 38 50 / 48 / 44 48 / 45 / 40 50 / 47 / 44 51 / 48 / 45 50 / 47 / 45 dB(A) 57 56.5 60.5 59.5 61 62.5 65 62.5 H (mm) 210 270 270 270 300 300 300 300 W (mm) 700 920 920 1 140 1 200 1 200 1 200 1 200 dB(A) Outdoor D (mm) 635 635 635 775 865 865 865 865 H (mm) 554 554 702 810 810 810 1 333 1 333 W (mm) 800 800 845 946 946 946 952 952 D (mm) 333 333 363 410 410 410 410 410 Indoor unit kg 18.4 26.9 28 35 45 43.4 43.2 43.1 Outdoor unit kg 34.5 35.5 49 62.9 67.2 70.5 95.1 112.8 Gas 3/8” 1/2” 5/8” 5/8” 5/8” 5/8” 5/8” 5/8” Liquid 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Dimensions Outdoor Net weight 0 / 45 42 / 38 / 35 Pa Indoor (H/M/L) Indoor 1360 / 1200 / 970 1580 / 1400 / 1100 1750 / 1500 / 1280 2200 / 1900 / 1600 2200 / 1900 / 1600 2200 / 1900 / 1600 Type of connection Piping Pipe run Diameter Flare Length m 25 30 50 50 65 65 65 65 Height m 10 20 25 25 30 30 30 30 36 42 48 55 Operating limits - cooling mode min/max -15°C / +50°C Operating limits - heating mode min/max -15°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Size 36, 42 and 48: Values for single phase models. Accessories Sizes 12 18 24 30 Condensate pump Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 31 32 YORK® AIR-CONDITIONING PRODUCTS Minisplit On/Off Systems high wall on/off floor/ceiling on/off cassette on/off blower on/off 33 High Wall On/Off Monte Rosa YHGE 09 to 24 ZE--MJORX A complete range from 2.6 kW to 7.0 kW Features Remote controller • Low noise levels • Multi-speed fan • Automatic restart • Automatic air sweep • LED display • 3-Minute protection • Self diagnosis • Refrigerant leakage detect • Service valve protection cover • Rustproof casing • Blue fin protection (indoor and outdoor units) • Wireless • Follow me function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • 5 Fan speeds selection • Quiet/sleep button • ON/OFF timer • Air flow direction setting • LCD display • Turbo mode • Room temperature setting 34 YORK® AIR-CONDITIONING PRODUCTS High Wall On/Off Monte Rosa YHGE 09 to 24 ZE--MJORX Technical features Set reference YHGE_ZE--MJORX Indoor unit Sizes YHGE09XE--MJ-RX YHGE12XE--MJ-RX YHGE18XE--MJ-RX YHGE24XE--MJ-RX Outdoor unit Sizes YHGE09YE--MJO-X YHGE12YE--MJO-X YHGE18YE--MJO-X YHGE24YE--MJO-X Cooling capacity kW 2.6 3.5 5.3 7.0 Heating capacity kW 2.8 3.8 5.6 7.3 Compressor Type Rotary Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 + E cooling kW 0.82 1.09 1.64 2.50 heating kW 0.77 1.05 1.54 2.28 EER 3.21 3.21 3.21 2.81 COP 3.61 3.61 3.61 3.21 cooling A A A C heating A A A C Power input Energy Class Indoor airflow m3/h 510 / 380 / 338 568 / 440 / 352 820 / 665 / 543 1 000 / 796 / 640 Sound pressure Indoor (H/M/L) at 1 m Outdoor dB(A) 40 / 33 / 26 41 / 36 / 31 43 / 38 / 33 47 / 40 / 34 dB(A) 55.5 56 56 60 H (mm) 285 285 302 327 W (mm) 715 805 957 1 040 D (mm) 194 194 213 220 H (mm) 550 555 555 702 Outdoor W (mm) 700 770 770 845 D (mm) 270 300 300 363 Indoor unit kg 6.8 7.2 9.5 11.9 Outdoor unit kg 26.4 30 35.8 48.8 Indoor Dimensions Net weight Type of connection Piping Diameter Refrigerant charge Pipe run Flare Gas 3/8” 1/2” 1/2” 5/8” Liquid 1/4” 1/4” 1/4” 3/8” 1 750 g 730 740 1 150 Length m 20 20 25 25 Height m 8 8 10 10 18 24 Operating limit - cooling mode min./max. +18°C / +43°C Operating limit - heating mode min./max. -7°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 09 12 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 35 Floor/Ceiling On/Off YFGE 12 to 55 BZE(O) A complete range from 3.5 kW to 16.1 kW Features Remote controller • Convertible - floor or ceiling • Washable filter • High velocity air flow • Automatic restart • Automatic air sweep • Horizontal and vertical air sweep function • Different swing angle design for cooling and heating • 2-way drainage • Service valve protection cover • Rustproof casing • Self diagnosis • Blue fin protection (indoor and outdoor units) • Wireless • Follow me function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer setting function • Air flow direction setting • LCD display • Turbo mode 36 YORK® AIR-CONDITIONING PRODUCTS Floor/Ceiling On/Off YFGE 12 to 55 BZE(O) Technical features Set reference YFGE_BZE--MO(S)RX Indoor unit Sizes YFGE 12 YFGE 18 YFGE 24 YFGE 36 YFGE 48 YFGE 55 Outdoor unit Sizes YUGE 12 YUGE 18 YUGE 24 YUGE 36 YUGE 48 YUGE 55 Cooling capacity kW 3.5 5.3 7.0 10.6 14.1 16.1 Heating capacity kW 3.8 5.7 7.6 11.6 15.2 17.6 Compressor Type Rotary Scroll Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 400 / 3 / 50 cooling kW 1.25 1.88 2.63 3.98 5.45 6.40 heating kW 1.28 1.73 2.45 3.70 5.25 5.88 EER 2.80 2.80 2.67 2.65 2.58 2.52 COP 2.98 3.22 3.11 3.13 2.90 3.03 Power input Energy Class cooling C C D D E E heating D C D D D D m3/h 620 / 500 / 400 1 150 / 950 / 800 1 250 / 1 050 / 900 1 750 / 1 400 / 1 250 1 750 / 1 400 / 1 250 2 300 / 1 800 / 1 120 Indoor (H/M/L) dB(A) 37 / 33 / 30 53 / 48 / 43 54 / 49 / 43 53 / 48 / 44 53 / 48 / 44 55 / 49 / 46 Outdoor dB(A) 59 62 62 61 63 63 H (mm) 675 675 675 675 675 675 W (mm) 1 068 1 068 1 068 1 285 1 285 1 650 D (mm) 235 235 235 235 235 235 H (mm) 555 555 702 965 1 170 1 170 Indoor airflow Sound pressure at 1 m Indoor Dimensions W (mm) 770 770 845 990 900 900 D (mm) 300 300 363 345 350 350 Indoor unit kg 23.6 24 24.6 29 31 39 Outdoor unit kg 30.5 36.5 52.7 85 93.2 97 Outdoor Net weight Type of connection Piping Diameter Pipe run Flare Gas 1/2” 1/2” 5/8” 3/4” 3/4” 3/4” Liquid 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” Length m 18 25 25 30 50 50 Height m 8 15 15 20 25 25 36 48 55 Operating limits - cooling mode min/max +18°C / +43°C Operating limits - heating mode min/max -7°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 12 18 24 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 37 Cassette On/Off YTGE 12 to 18 BZE / YKGE 18 to 55 BZE(O) A complete range from 3.5 kW to 16.1 kW Features Remote controller • 360° Air outlet • Low noise • Washable air filter • Fresh air intake • Built-in drain pump • Automatic restart • Automatic air sweep • Different swing angle design for cooling and heating • Service valve protection cover • Rustproof casing • Self diagnosis • Blue fin protection (indoor and outdoor units) • Wireless • Follow me function • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer setting function • Air flow direction setting • LCD display • Turbo mode 38 YORK® AIR-CONDITIONING PRODUCTS Cassette On/Off YTGE 12 to 18 BZE / YKGE 18 to 55 BZE(O) Technical features Set reference YTGE_BZE YKGE_BZE(O) Indoor unit Sizes YTGE 12 YTGE 18 YKGE 18 YKGE 24 YKGE 36 YKGE 48 YKGE 55 Outdoor unit Sizes YUGE 12 YUGE 18 YUGE 18 YUGE 24 YUGE 36 YUGE 48 YUGE 55 Cooling capacity kW 3.5 5.3 5.3 7.0 10.6 14.1 16.1 Heating capacity kW 3.8 5.7 5.7 7.6 11.7 15.2 17.6 Compressor Type Rotary Scroll Refrigerant R410A Power supply Power input V/Ph/Hz 400 / 3 / 50 cooling kW 1.25 1.84 1.99 2.60 3.98 5.19 heating kW 1.46 1.90 1.74 2.40 3.60 4.76 5.92 2.80 2.80 2.65 2.71 2.65 2.71 2.59 2.97 EER 6.20 2.89 3.24 3.20 3.18 3.25 3.20 cooling C C D D D D E heating D C D D C D D COP Energy Class 230 / 1 / 50 Indoor airflow m3/h 560 / 550 / 430 810 / 650 / 530 900 / 750 / 600 Sound pressure Indoor (H/M/L) at 1 m Outdoor dB(A) 42 / 38 / 36 48 / 41 / 36 43 / 40 / 35 50 / 45 / 41 51 / 47 / 43 53 / 48 / 44 dB(A) 59 62 62 62 61 63 63 H (mm) 260 260 205 205 245 245 300 W (mm) 570 570 840 840 840 840 840 D (mm) 570 570 840 840 840 840 840 H (mm) 555 555 555 702 965 1 170 1 170 900 Indoor Dimensions Outdoor Net weight 770 770 770 845 990 900 D (mm) 300 300 300 363 345 350 350 50 / 647 / 647 50 / 647 / 647 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 Panel H / W / D mm Indoor unit kg 18.8 19 27 27.1 30 32 37 Outdoor unit kg 30.5 36.5 36.5 52.7 85 93.2 97 Gas 1/2” 1/2” 1/2” 5/8” 3/4” 3/4” 3/4” Liquid 1/4” 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” Diameter Pipe run 51 / 47 / 42 W (mm) Type of connection Piping 1200 / 1050 / 900 1800 / 1600 / 1400 1900 / 1600 / 1400 1800 / 1480 / 1280 Flare Length m 18 25 25 25 30 50 50 Height m 8 15 15 15 20 25 25 36 48 55 Operating limits - cooling mode min/max +18°C / +43°C Operating limits - heating mode min/max -7°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 12 18 18 24 Wired control Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 39 Blower On/Off Medium Static Pressure YEGE 12 to 55 BZE(O) A complete range from 3.5 kW to 16.1 kW Features Wired control • Washable air filter • High velocity air flow • Automatic restart • Condensate pump optional • Low noise levels • Wired control • Reserved remote on-off and alarm ports • Wireless controller optional • 3-Minute protection • Service valve protection cover • Rustproof casing • Self diagnosis • Blue fin protection (indoor and outdoor units) • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer • LCD display 40 YORK® AIR-CONDITIONING PRODUCTS Blower On/Off Medium Static Pressure YEGE 12 to 55 BZE(O) Technical features Set reference YEGE_BZE(O)--MO(S)WX Indoor unit Sizes YEGE 12 YEGE 18 YEGE 24 YEGE 36 YEGE 48 YEGE 55 Outdoor unit Sizes YUGE 12 YUGE 18 YUGE 24 YUGE 36 YUGE 48 YUGE 55 Cooling capacity kW 3.5 5.3 7.0 10.6 14.1 16.1 Heating capacity kW 3.8 5.7 7.6 11.7 16.1 17.6 Compressor Type Rotary Scroll Refrigerant R410A Power supply Power input V/Ph/Hz kW 1.25 1.97 2.65 3.82 5.24 heating kW 1.31 1.76 2.50 3.65 4.52 5.18 2.80 2.69 2.65 2.76 2.68 2.59 3.39 2.91 3.16 3.05 3.21 3.56 C D D D D E heating D D D C B C 624 / 485 / 400 816 / 546 / - 1 260 / 808 / - 1 848 / 1 106 / - 2 282 / 1 439 / - 2 275 / - / - 0 - 60 0 - 60 0 - 80 0 - 80 0 - 100 0 - 120 40 / 36 / 32 43 / 37 / 36 45 / 40 / 38 48 / 40 / 37 50 / 45 / 40 47 / 40 / 38 Indoor airflow m3/h External static pressure Pa Indoor (H/M/L) dB(A) Outdoor dB(A) 59 62 62 61 63 63 H (mm) 210 210 270 270 300 300 W (mm) 700 920 920 1 140 1 200 1 200 D (mm) 635 635 635 795 795 865 H (mm) 555 555 702 965 1 170 1 170 Indoor Dimensions W (mm) 770 770 845 990 900 900 D (mm) 300 300 363 345 350 350 Indoor unit kg 18.3 24 26.5 36 44.5 47 Outdoor unit kg 30.5 36.5 52.7 85 93.2 97 Outdoor Net weight Type of connection Piping Diameter Pipe run 6.22 cooling COP Sound pressure at 1 m 400 / 3 / 50 cooling EER Energy Class 230 / 1 / 50 Flare Gas 1/2” 1/2” 5/8” 3/4” 3/4” 3/4” Liquid 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” Length m 18 25 25 30 50 50 Height m 8 15 15 20 25 25 36 48 55 Operating limits - cooling mode min/max +18°C / +43°C Operating limits - heating mode min/max -7°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 12 18 24 Condensate pump Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 41 Blower On/Off High Static Pressure YGGE 24 to 55 BZE(O) A complete range from 5.3 kW to 16.4 kW Features Wired control • Washable air filter • High velocity air flow • Automatic restart • Condensate pump optional • Low noise levels • Wired control • Reserved remote on-off and alarm ports • Wireless controller optional • 3-Minute protection • Service valve protection cover • Rustproof casing • Self diagnosis • Blue fin protection (indoor and outdoor units) • 5 operation modes (Cool/Heat/Auto/Dry/Fan) • Sleep mode • Room temperature setting • Fan speed selection • Timer • LCD display 42 YORK® AIR-CONDITIONING PRODUCTS Blower On/Off High Static Pressure YGGE 24 to 55 BZE(O) Technical features Set reference YEGE_BZE(O)--MO(S)WX Indoor unit Sizes YEGE 24 YEGE 36 YEGE 48 YEGE 55 Outdoor unit Sizes YUGE 24 YUGE 36 YUGE 48 YUGE 55 Cooling capacity kW 7.0 10.6 14.1 16.4 Heating capacity kW 7.6 11.7 15.2 18.2 Compressor Type Rotary Scroll Refrigerant R410A Power supply V/Ph/Hz 230 / 1 / 50 400 / 3 / 50 cooling kW 2.71 3.88 5.41 6.50 heating kW 2.27 3.24 4.22 5.30 EER 2.60 2.72 2.60 2.53 COP 3.36 3.61 3.61 3.43 cooling E D E E heating C A A B 1 615 / 1 155 / 989 2 148 / 1 810 / 1 648 2 809 / 2 554 / 2 272 3 150 / 2 809 / 2 554 0 - 120 0 - 169 0 - 200 0 - 200 48 / 42 / 38 53 / 50 / 47 51 / 49 / 46 52 / 50 / 48 Power input Energy Class Indoor airflow m3/h External static pressure Pa Sound pressure at 1 m Indoor (H/M/L) dB(A) Outdoor dB(A) 62 61 63 63 H (mm) 270 270 380 380 W (mm) 900 1 100 1 200 1 200 D (mm) 525 525 625 625 H (mm) 702 965 1 170 1 170 W (mm) 845 990 900 900 D (mm) 363 345 350 350 Indoor unit kg 25 31.3 46 45.9 Outdoor unit kg 52.7 85 93.2 97 Indoor Dimensions Outdoor Net weight Type of connection Piping Diameter Pipe run Flare Gas 5/8” 3/4” 3/4” 3/4” Liquid 3/8” 3/8” 3/8” 3/8” Length m 25 30 50 50 Height m 15 20 25 25 48 55 Operating limits - cooling mode min/max +18°C / +43°C Operating limits - heating mode min/max -7°C / +24°C Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB Piping length : 5 m with initial charge Accessories Sizes 24 36 Condensate pump Optional Central control Optional Manufacturer reserves the rights to change specifications without prior notice. 43 44 YORK® AIR-CONDITIONING PRODUCTS VRF Systems high efficiency series amazon standard series indoor unit types 45 VRF System High Efficiency YV2VYH 025 to 204 Cooling capacities 25.4 kW to 211.2 kW VRF System Comfort – Quality • Capacities from 25.4 to 211.2 kW • Operating range of nominal power (10% - 130 %) • DC Inverter Scroll Compressor • Low noise levels • High Efficiency. EER up to 4.29 • Modular design • Long piping design up to 1000 m • Big height difference design: 90 m • Height difference between indoors: 18 m • Large indoor unit combinations • Flexible and quickly installation • Cooling and heating • Connection up to 64 indoor units per refrigeration circuit (3 outdoor units) • Complete range in R410A • Reduced footprint • Is appropriate particularly for existing buildings • Cooling to -5°C to +43°C (outdoor temperature) • Heating to -15°C to +24°C (outdoor temperature) 46 YORK® AIR-CONDITIONING PRODUCTS YV2VYH Technical features - Single module outdoor unit Model Cooling capacity kW EER Heating capacity kW COP YV2VYH025 YV2VYH028 YV2VYH033 YV2VYH040 YV2VYH045 YV2VYH050 YV2VYH056 YV2VYH061 YV2VYH068 25.4 28.9 34.8 41.5 46.4 51.5 57.8 63.7 70.4 4.29 4.00 3.90 3.55 3.47 3.42 3.34 3.18 3.09 28.1 32.4 37.9 45.8 51.1 57.2 63.7 70.1 73.9 4.30 4.19 3.71 3.84 3.82 3.74 3.75 3.73 3.83 Air flow in cooling m3/h 15 000 15 000 15 000 15 000 15 600 16 200 16 200 16 200 16 200 Sound Pressure Level at 1 m dB(A) 57 57 59 59,5 61 62 62 62 63 Electrical features 380V-3-50/60Hz Power supply Power input “cooling” kW 5.87 7.00 8.60 11.27 12.97 14.73 16.79 19.37 21.98 Power input “heating” kW 6.28 7.52 10.12 11.73 13.10 15.12 16.79 18.48 19.08 Compressor Type DC Inverter Scroll 2 x DC Inverter Scroll Dimensions and Weight Height x Width x Length mm Weight kg 1690x1350x720 1690x1350x720 1690x1350x720 1690x1350x720 1690x1350x720 2048x1350x720 2048x1350x720 2048x1350x720 2048x1350x720 278 278 278 282 324 343 343 369 369 Piping connections 1” 1” 1” 1” 1/4” 1” 1/4” 1” 1/4” 1” 1/4” 1” 1/4” 1” 1/4” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 10 10 10 10 30 33 36 40 Gas Liquid Type Refrigerant charge R410A kg 10 10 10 10 10 Piping length / Height difference Max. piping length farthest indoor unit (m) 190 Max. height difference indoor/outdoor (m) 50 Max. number of indoor units 13 16 20 24 27 Models available to be confirmed as soon as they are launched (estimated Mar’15) Combination of modular outdoor units Model 074 080 085 090 095 101 106 Capacity Cooling kW 76.3 83.0 Heating kW 83.7 Maximum indoor units 43 91.6 46 87.9 93.0 112 118 124 130 136 141 146 151 157 162 168 174 180 186 192 198 204 97.9 104.2 109.3 115.6 121.5 128.2 140.0 140.8 144.5 150.6 155.7 162.0 167.1 173.4 179.3 186.0 191.9 198.6 204.5 211.2 96.9 103.0 108.3 114.8 120.9 127.4 133.8 137.6 144.0 147.8 160.2 165.9 172.0 178.5 184.6 191.1 197.5 201.3 207.7 211.5 217.9 221.7 50 53 57 60 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 Appearance DX-Kit Available for all type of 2-pipe outdoor units York offers a range of connection kit to connect VRF outdoor units to third party DX air handling units. Two models availables: • YAH1-280A (up to 28 kW) • YAH1-560A (up to 56 kW) Manufacturer reserves the rights to change specifications without prior notice. 47 YCZ-G001 Central Controller Available for all type of outdoor units • Max. 32 indoor units control. • Max. 32 outdoor units control. • On/Off, Mode, Fan speed, Temperature setting, Swing. • Individual control, Group control & Central control (Max. 32 indoor units) • Color interface with back light • Large touch key • Fahrenheit/Celsius selectable • Weekly timer • Unit name & Group name free setting. Four background available (mall, hotel, office, home) • Error display • Together with one IGU05 per outdoor unit 64 Amazon Standard Ambient VRF System YV2V 010 to 135 Cooling capacities 9 kW to 135 kW VRF System Comfort – Quality • Capacities from 9 to 135 kW • Operating range of nominal power (10% - 130 %) • DC Inverter Scroll Compressor • Low noise levels • High Efficiency. EER up to 4.28 • Modular design • Large indoor unit combinations • Flexible and quickly installation • Cooling and heating • Connection up to 64 indoor units per refrigeration circuit (3 outdoor units) • Complete range in R410A • Reduced space of ground • Is appropriate particularly for existing buildings • Cooling to -5°C to +43°C (outdoor temperature) • Heating to -15°C to +24°C (outdoor temperature) 48 YORK® AIR-CONDITIONING PRODUCTS YV2V Technical features - Mini-VRF outdoor unit Model YV2VYH010KAR YV2VYH015KAR YV2VYH015KAS YV2VYH018KAS m3/h dB(A) 9.0 2.98 11.0 4.20 3 500 58 15.0 3.33 17.0 3.78 6 500 59 15.0 3.06 17.0 3.95 6 500 59 18.0 2.84 20.0 3.37 6 500 60 kW kW Type 3.02 2.62 Rotary 4.50 4.50 Rotary 4.90 4.30 Rotary 6.33 5.93 Rotary mm kg 830 x 960 x 380 74 1 250 x 960 x 380 120 1 250 x 960 x 380 120 1 250 x 960 x 380 120 5/8” 3/8” 3/4” 3/8” 3/4” 3/8” 3/4” 3/8” 2.6 3.6 4 4 50 30 4 100 30 8 100 30 8 100 30 9 kW Cooling capacity EER Heating capacity COP Air flow Sound Pressure Level at 1 m kW Electrical features 1/N/ 230V 50Hz Power supply Power input “cooling” Power input “heating” Compressor 3/N/ 400V 50Hz Dimensions and Weight Height x Width x Length Weight Piping connections Gas Liquid Type kg Refrigerant charge R410A Piping length / Height difference m m Max. piping length Max. height difference Max. number of indoor units YV2V Technical features - Single module outdoor unit Model YV2VYH022KAS YV2VYH028KAS YV2VYH033KAS YV2VYH040KAS YV2VYH045KAS 22.6 4.28 25.0 4.24 11.100 57 28.0 3.80 31.5 3.95 11.100 57 33.5 3.35 37.5 3.75 14.100 60 40.0 3.51 45.0 3.88 14.100 60 45.0 3.36 50.0 3.70 14.100 60 kW kW Type 5.27 5.89 7.36 7.97 3/N/ 400V 50Hz 10.00 10.00 11.40 11.60 DC Inverter Scroll + Standard Scroll 13.40 13.50 mm kg 1 808 x 990 x 750 240 1 808 x 990 x 751 240 1 808 x 1 390 x 750 360 1 808 x 1 390 x 751 360 1 808 x 1 390 x 752 368 3/4” 3/8” 7/8” 3/8” 1” 1/2” 1 1/8” 1/2” 10 10 1” 1/2” R410A 10 10 10 16 175 50 19 23 26 kW Cooling capacity EER Heating capacity COP Air flow Sound Pressure Level at 1 m kW m3/h dB(A) Electrical features Power supply Power input “cooling” Power input “heating” Compressor DC Inverter Scroll Dimensions and Weight Height x Width x Length Weight Piping connections Gas Liquid Type kg Refrigerant charge Piping length / Height difference Max. piping length farthest indoor unit (m) Max. height difference indoor/outdoor (m) Max. number of indoor units 13 Combination of modular outdoor units 050 056 061 068 073 078 085 090 096 101 106 113 118 123 130 135 Capacity Cooling kW Model 50.6 56.0 61.5 68.0 73.0 78.5 85.0 90.0 96.0 101.0 106.5 113.0 118.0 123.5 130.0 135.0 Heating kW 56.5 63.0 69.0 76.5 81.5 90.0 95.0 100.0 108.0 113.0 121.5 126.5 131.5 137.5 145.0 150.0 29 33 36 39 43 46 50 53 56 59 63 64 64 64 64 64 Maximum indoor units Appearance Manufacturer reserves the rights to change specifications without prior notice. 49 VRF Heat recovery system YV2V 024 to 045 YV2V 3 Pipes Technical features - Single module outdoor unit Model YV2VYT024KAS-D-X YV2VYT029KAS YV2VYT035KAS YV2VYT042KAS YV2VYT045KAS 23.9 29.3 35.1 41.7 45.0 4.02 3.84 3.82 3.42 3.23 kW 26.5 32.8 39.2 46.8 50.7 4.3 4.1 4.2 4.1 3.8 Air flow m3/h 11.100 11.100 14.100 14.100 14.100 Sound Pressure Level at 1 m dB(A) 57 57 60 60 60 Power input “cooling” kW 6.0 7.6 9.2 12.2 14.0 Power input “heating” kW 6.2 8.0 9.2 11.4 13.4 Compressor Type Cooling capacity kW EER Heating capacity COP Electrical features 3/N/ 400V 50Hz Power supply DC Inverter Scroll DC Inverter Scroll + Standard Scroll Dimensions and Weight Height x Width x Length mm 1 808 x 990 x 750 1 808 x 990 x 750 1 808 x 1 390 x 750 1 808 x 1 390 x 750 1 808 x 1 390 x 750 Weight kg 240 240 368 368 368 3/4” / 3/4” 7/8” / 3/4” 1” / 7/8” 1” / 7/8” 1 1/8” / 1” 3/8” 3/8” 1/2” 1/2” 1/2” 10 10 23 26 Piping connections Gas Liquid Refrigerant charge Type R410A kg 10 10 10 Piping length / Height difference Max. piping length farthest indoor unit (m) 175 Max. height difference indoor/outdoor (m) 50 Max. number of indoor units 13 16 19 Combination of modular outdoor units HP Capacity Coolin kW Heating kW Maximum indoor units 8 10 12 15 16 18 20 22 24 26 28 30 32 23.9 29.3 35.1 41.7 45.0 53.2 58.6 64.4 71.0 74.3 83.4 86.7 90.0 26.5 32.8 39.2 46.8 50.7 59.3 65.6 72.0 79.6 83.5 93.6 97.5 101.4 112.4 116.3 126.4 130.3 134.2 140.6 148.2 152.1 13 16 19 23 26 29 33 36 39 43 46 50 53 34 36 38 40 42 44 56 59 63 64 64 64 Appearance Technical features - Heat recovery valve box Model VB1-112A VB1-180A VB1-280A Capacity 3/N/ 400V 50Hz Power supply Total Capacity Index of Indoor Units kW Number of Connectable Indoor Units ≤ 11.2 > 11.2 & ≤ 18.0 > 18.0 & ≤ 28.0 Max. 5 Max. 8 Max. 8 3/8” Piping connection Liquid pipe - Connect to indoor unit mm 3/8” 3/8” Gas pipe -Connect to indoor unit mm 5/8” 5/8” 7/8” Liquid pipe-Connect to outdoor unit mm 3/8” 3/8” 3/8” Suction pipe-Connect to outdoor unit mm 5/8” 5/8” 1” High pressure gas pipe-Connect to outdoor unit mm 1/2” 5/8” 3/4” mm 180 x 400 x 300 180 x 400 x 300 180 x 400 x 300 12 12 13 Dimensions & Weight Height x Width x Length Weight kg 50 46 48 100.3 103.6 112.7 116.0 119.3 125.1 131.7 135.0 64 64 YORK® AIR-CONDITIONING PRODUCTS VRF Heat recovery system Heat recovery valve box scheme Outdoor unit side (3 pipes) Indoor unit side (2 pipes) Gas pipe HP gas pipe Liquid pipe Suction pipe Liquid pipe Cooling and heating synchronously in one system Heat recovery system can achieve cooling and heating synchronously in one system by valve box device. 2-Pipe system Cooling and heating in two systems Heat recovery system (3-Pipe) Cooling and heating in one systems Heat Recovery, More Energy-saving The surplus heat of some indoor units’ condensation can be used for other indoor units for evaporation. Comparing with traditional Air Conditioning system, save at least 15% energy. Manufacturer reserves the rights to change specifications without prior notice. 51 VRF Technical features indoor units High wall (EXV integrated) Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid kW kW m3/h dB(A) V/Ph/Hz A mm kg YVHVXH022 2.2 2.5 YVHVXH028 2.8 3.2 37 / 33 / 31 37 / 34 / 31 YVHVXH036 3.6 4.0 YVHVXH045 4.5 5.0 YVHVXH056 5.6 6.3 600 YVHVXH071 7.1 8.0 800 41 / 36 / 33 41 / 36 / 33 230 / 1 / 50 + N + E 0.31 265 x 938 x 187 10.9 1/2” 1/4” 43 / 39 / 34 48 / 39 / 37 0.41 299 x 1 046 x 239 13 5/8” 3/8” Cassette Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight HxWxD Panel Weight Gas Piping Liquid kW kW m3/h dB(A) V/Ph/Hz A mm kg mm kg YVKVXH028 YVKVXH036 YVKVXH045 YVKVXH056 YVKVXH071 YVKVXH080 YVKVXH090 YVKVXH112 YVKVXH140 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 700 650 1 200 1 800 32 / 30 / 29 32 / 30 / 29 33 / 30 / 29 34 / 32 / 30 35 / 34 / 31 37 / 35 / 31 37 / 35 / 31 37 / 35 / 31 44 / 40 / 36 230 / 1 / 50 + N + E 0.47 0.67 0.76 260 x 570 x 570 240 x 840 x 840 295 x 840 x 840 17 30 38 60 x 700 x 700 80 x 950 x 950 2.8 6 3/8” 1/2” 5/8” 1/4” 1/4” 3/8” Convertible console floor/ceiling Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid kW kW m3/h dB(A) V/Ph/Hz A mm kg YVFVXH028 2.8 3.2 YVFVXH036 3.6 4.0 YVFVXH045 4.5 5.0 800 48 / 46 / 44 YVFVXH056 5.6 6.3 YVFVXH071 7.1 8.0 YVFVXH112 11.2 12.5 YVFVXH140 14.0 16.0 2 040 50 / 48 / 46 53 / 51 / 49 230 / 1 / 50 + N + E 0.3 655 x 990 x 199 38.3 1/2” 1/4” 3/8” 1/4” 1.8 700 x 1 580 x 240 54 5/8” 3/8” Console Model Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid kW kW m3/h dB(A) V/Ph/Hz A mm kg YV5VXH022 2.2 2.5 YV5VXH028 2.8 3.2 YV5VXH036 3.6 4.0 520 460 43 / 39 / 36 230 / 1 / 50 + N + E 0.44 640 x 720 x 255 18 1/2” 1/4” 52 YV5VXH056 5.0 6.0 580 48 / 46 / 42 YORK® AIR-CONDITIONING PRODUCTS VRF Technical features indoor units Low and Medium Static Pressure Duct Model Cooling Heating Air flow Noise level at 1 m H / M / L External static presure Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid Capacity Low Static Pressure Medium Static Pressure YVDVXH022 YVDVXH028 YVDVXH036 YVDVXH045 YVDVXH056 YVDVXH071 YVEVXH056 YVEVXH071 YVEVXH080 YVEVXH090 YVEVXH112 YVEVXH114 kW 2.2 2.8 3.6 4.5 5.6 7.1 5.6 7.1 8.0 9.0 11.2 14.0 kW 2.5 3.2 4.0 5.0 6.3 8.0 7.1 8.0 9.0 10.0 12.5 16.0 m3/h 400 500 850 1 250 1 200 1 900 2 100 dB(A) 35 / 32 / 30 39 / 37 / 35 43 / 37 / 35 44 / 40 / 36 Pa 0 ~ 20 50 ~ 96 80 ~ 120 V/Ph/Hz 230 / 1 / 50 + N + E A 0.27 0.38 0.55 1.1 2.2 mm 220 / 610 / 500 220 / 1 105 / 500 300 / 1 180 / 743 270 / 1 135 / 742 kg 15 16 25 28 39 50 3/8” 1/2” 5/8” 1/2” 5/8” 1/4” 1/4” 3/8” 1/4” 3/8” High Static Pressure Duct Model Cooling Capacity Heating Air flow Noise level at 1 m H / L External static presure Power supply Electrical features Current HxWxD Dimensions and Weight Weight Gas Piping Liquid kW kW m3/h dB(A) Pa V/Ph/Hz A mm kg YVGVXH056 5.6 6.3 YVGVXH071 7.1 8.0 1 500 42 / 40 YVGVXH080 8.0 9.0 YVGVXH090 9.0 10.0 1 560 YVGVXH112 11.2 12.5 1 600 45 / 40 YVGVXH140 14.0 16.0 2 100 100 230 / 1 / 50 + N + E 2.55 360 x 1 350 x 875 62 5/8” 3/8” 2.05 360 x 970 x 875 48 1/2” 1/4” YVGVXH226 YVGVXH280 22.6 28.0 25.0 31.6 4 050 54 / 49 5.05 360 x 1 610 x 840 92 1” 3/8” Fresh Air Unit Model Cooling Capacity Heating Air flow Noise level at 1 m High speed External static presure Electrical features Power supply HxWxD Dimensions and Weight Weight Gas Piping Liquid kW kW m3/h dB(A) Pa V/Ph/Hz mm kg YV4VXH140 14.0 8.9 1 600 48 YV4VXH226 22.6 15.2 2 300 YV4VXH280 28.0 17.8 2 800 55 100 230 / 1 / 50 + N + E 360 x 1 350 x 875 62 5/8” 3/8” 360 x 1 750 x 840 120 1” 3/8” Heat Recovery Ventilator Model Air flow External static presure Power supply HxWxD Dimensions and Weight Weight m3/h Pa V/Ph/Hz mm kg YV6VXH015 150 50 YV6VXH026 200 60 276x940x685 276x940x686 YV6VXH080 800 80 YV6VXH100 1 000 100 230 / 1 / 50 + N + E 28.7 387x1227x1115 387x1227x1116 85.5 Manufacturer reserves the rights to change specifications without prior notice. 53 Controllers & BMS YR-H71 Wireless Controller Elegant and slim design, LCD display, 4 Operation modes (Cool/Dry/Heat/Fan), Timer ON/OFF setting up to 24 Hr., Temperature control range, Fan speed selection. Standard for High Wall and Console, optional for Duct, Cassette and Floor Ceiling. YR-E17 Wired Controller Exclusive design, Big LCD display, 4 Operation modes (Cool/Dry/Heat/Fan), Temperature setting, Timer setting,Fan speed selection, Group controller up to 16 indoor units. Standard for Duct, Cassette and Floor Ceiling. Optional for High Wall and NO optional for Console. YCZ-A003 Touch Screen Central Controller Max. 128 indoor units control. Single or all query and control, such as ON/OFF/Mode setting/Temp setting/ Fan setting ect. Mode lock function, Blue light background, LCD display screen. IGU05 Touch Screen Central Controller Translator Translating protocol between home bus and RS485. Connecting with one outdoor (combination model also regard as one) system. Work with Touch Screen Central Controller HCM-01 Central Controller With Monitor Software Max. 128 indoor units control. Single or all query and control, such as ON/OFF/Mode setting/Temp setting/ Fan setting ect. Mode lock function, Blue light background, Software Monitoring on any PC. IGU02 BacNet/IP Translator IGU06 LonWorks Translator Translating protocol between home bus and RS485. Connecting with one outdoor (combination model also regard as one) system. Work with Central Controller with Monitor Software and BacNet/IP Converter. Translating protocol between home bus and RS485. Connecting with one outdoor (combination model also regard as one) system. Work with LonWorks Converter. HCM-04 BacNet/IP Converter IGU07 LonWorks Converter Max. 60 indoor units control. Connect A/C system to BMS by BacNet/IP protocol. Max. 32 indoor units control. Connect A/C system to BMS by LONWORKS protocol. 54 YORK® AIR-CONDITIONING PRODUCTS VRF System - System Diagram Possible to connect to JCI Metasys Piping accessories Model FQG-B335A FQG-B506A FQG-B730A FQG-B1350A HZG-20A HZG-30A HZG-20B HZG-30B FQG-R335A FQG-R506A FQG-R730A FQG-R1350A HZG-R20A HZG-R30A System Name Function Application 2 pipes 2 pipes 2 pipes 2 pipes 2 pipes 2 pipes 2 pipes HE 2 pipes HE 3 pipes 3 pipes 3 pipes 3 pipes 3 pipes 3 pipes Indoor mainfold pipe Indoor mainfold pipe Indoor mainfold pipe Indoor mainfold pipe Outdoor branch pipe Outdoor branch pipe Outdoor HE branch pipe Outdoor HE branch pipe Indoor mainfold pipe Indoor mainfold pipe Indoor mainfold pipe Indoor mainfold pipe Outdoor branch pipe Outdoor branch pipe Refrigerant distribution Refrigerant distribution Refrigerant distribution Refrigerant distribution Refrigerant gathering Refrigerant gathering Refrigerant gathering Refrigerant gathering Refrigerant distribution Refrigerant distribution Refrigerant distribution Refrigerant distribution Refrigerant gathering Refrigerant gathering Total indoor units capacity < 33.5 kW 33.5 kW ≤ Total indoor units capacity < 50.6 kW 50.6 kW ≤ Total indoor units capacity < 72 kW 73 kW ≤ Total indoor units capacity 2 module combinations 3 module combinations 2 module HE combinations 3 module HE combinations Total indoor units capacity < 33.5 kW 33.5 kW ≤ Total indoor units capacity < 50.6 kW 50.6 kW ≤ Total indoor units capacity < 72 kW 73 kW ≤ Total indoor units capacity 2 module combinations 3 module combinations YORK VRF System A The YORK VRF system with DC Inverter Scroll is working like the VRF principle and offers you economical air-conditioning system for projects, which are requiring more capacity than the normal split and multi split solutions. B C The lengths for the connecting tubes between the indoor and outdoor have been prolonged, which brings you more flexible solutions for complex air-conditioning projects. A – Maximum single way pipe length: 175m B – Maximum difference in height: 50m (110m for HE outdoor units) C – Maximum difference in height between 2 indoor units: 15m (30m for HE outdoor units) 55 About Johnson Controls Johnson Controls delivers products, services and solutions that increase energy efficiency and lower operating costs in buildings for more than one million customers. Operating from 500 branch offices in more than 150 countries, the company is a leading provider of equipment, controls and services for heating, ventilating, air-conditioning, refrigeration and security systems. Johnson Controls is involved in more than 500 renewable energy projects including solar, wind and geothermal technologies. Its solutions have reduced carbon dioxide emissions by 13.6 million metric tons and generated savings of $7.5 billion since 2000. Many of the world’s largest companies rely on Johnson Controls to manage 1.5 billion square feet of their commercial real estate. PUBL-7393 - 02.2017 © 2017 Johnson Controls, Inc. · www.johnsoncontrols.co.uk Johnson Controls reserves the right, in line with continuing research and development, to amend or change specifications without notice. YORK® is a registered trademark of Johnson Controls, Inc. in the United States and other countries. 4
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement