EN YORK CAT MIN-VRF 2017.indd

EN YORK CAT MIN-VRF 2017.indd
YORK® RAC, PAC & VRF 2017
A more comfortable,
safe and sustainable world
RAC, PAC & VRF
Air-conditioning solutions
Every market is unique in air-conditioning requirements.
In this catalogue our customers will be able to select
the different options for residential market and VRF
solutions for Light-Commercial market.
Johnson Controls wants to offer all the possible solutions
for different building design and technical requirements,
and the air-conditioning is an important part of those
global solutions.
MINISPLIT SOLUTIONS
• High Wall inverter
• Multisplit inverter
• Floor/ceiling inverter
• Cassette inverter
• Blower inverter
4
YORK® AIR-CONDITIONING PRODUCTS
The majority of our products are already rated as Class A
or more for Energy Efficiency, in order to guarantee lower
consumption.
According to the market necessities our customers
can find the best solution in our wide product range
depending on the building characteristics.
VRF SOLUTIONS (Outdoor units)
• Capacities from 9 to 211 kW
• Operating range of nominal
power (10% - 130 %)
• DC Inverter Scroll Technology
• Low noise levels
• High performance
• Flexible and quickly installation
• Heat recovery
VRF SOLUTIONS (Indoor units)
• High Wall
• Cassette
• Convertible console floor/ceiling
• Console
• Blower
• Fresh air
• Heat recovery
5
Catalogue content
Pag.
Split Systems
High wall Inverter R32
YHKF 09 to 24 ZEEBMHORX
16
High wall Inverter Pyrenees
YHKE 09 to 24 ZEEAMHORX
18
High wall Inverter Monte Rosa
YHKE 09 to 24 ZE-MJORX
20
Multi Inverter “Free Indoor Units”
YJU_YH 14 to 45
22
Floor/Ceiling Inverter
YFKE 18 to 55
26
Cassette Inverter
YTKE 12 to 18 BZE / YKKE 18 to 55 BZE(O)
28
Blower Inverter Medium Static Pressure
YEKE 12 to 55 BZE(O)
30
High Wall On/Off Monte Rosa
YHGE 09 to 24 ZE--MJORX
34
Floor/Ceiling On/Off
YFGE 12 to 55 BZE(O)
36
Cassette On/Off
YTGE 12 to 18 BZE / YKGE 18 to 55 BZE(O)
38
Blower On/Off Medium Static Pressure
YEGE 12 to 55 BZE(O)
40
Blower On/Off High Static Pressure
YGGE 24 to 55 BZE(O)
42
VRF System High Efficiency
YV2VYH 025 to 204
46
Amazon Standard Ambient VRF System
YV2V 010 to 135
48
VRF Systems
6
YORK® AIR-CONDITIONING PRODUCTS
Cooling capacity kW
1.0
5.0
10.0
20.0
2.7 - 7.3
2.6 - 7.0
2.6 - 7.0
4.1 - 11.8
5.3 - 15.8
3.5 - 16.1
3.5 - 15.8
2.6 - 7.0
3.5 - 16.1
3.5 - 16.1
3.5 - 16.1
5.3 - 16.4
25.4 - 211.2
9 - 135
7
50.0
100.0
200.0
8
YORK® AIR-CONDITIONING PRODUCTS
efficiency and ecological inverter range
The High Wall inverter air conditioners have been designed thinking about comfort and sustainability. Comfort as the ultimate
technology of DC Inverter compressor installed in these units is able to achieve high performances in heating and cooling mode,
the temperature variations in the room are minimized and the noise level is lower.
Sustainable because the high efficiency of the unit results in a very low energy consumption, one of the most efficient in the
market, the materials used are recyclable and free of hazardous substances, all together makes this unit the appropriate choice
for conditioning your home.
The R32 is the new refrigerant that has a zero impact on the ozone layer and a smaller impact on global warming.
We are sure that technology improves people’s lives. This is why we introduce a new generation of air conditioners with R32,
an innovative refrigerant in every imaginable way: easy to install, environmentally friendly and energy saving.
R32
REFRIGERANT
9
10
YORK® AIR-CONDITIONING PRODUCTS
Main Features
EU Energy Label A Class
Auto-Restart Function
With the powerful compressor and optimized
refrigerant, the SEER can reach EU Energy
Label A Class (over 5.1 w/w) or B Class (over 4.6
w/w), greatly reducing the power consumption.
When the power supply is interrupted and then
restored, the air conditioners automatically restore
the previous function setting.
Turbo Mode
WiFi control
Press the Turbo button and the A/C will reach the
preset temperature in the shortest time.
With the WiFi control, you can easly turn off the AC
outside your house via smart device. Furthermore,
you can turn it on before you come back.
Sleep Mode
Low Ambient Kit
With Spleep Mode, the air conditioner’s set
temperature will automatically increase (cooling)
or decrease (heating) 1°C per hour for the first two
hours then hold steady for the next 5 hours after
which the air conditioner will stop operation. With
the sleep mode function can maintain the most
confortable temperature and save energy.
The air conditioning unit can operate in cooling
mode at low ambient temperature conditions.
The kit is suitable for special applications such as
computer and power station control rooms where
cooling is required even in the winter months.
Dehumidification
Anti-Rust Cabinet and Valve
Protection Cover
Independent dehumidification function is usually
used in rainy days in springtime or damps areas. The
unit will alternately operate in cooling mode or fan
only mode, which assures strong dehumidification
while not lowering room temperature.
Cabinet made from electrolytic zinc steel sheet and
anti-rust coated components. York’s outdoor units
are rust free even in coastal regions.
The valve protection cover protects the service
valves and prevents water from dripping.
Iconography
Infrared
control
Wired
control
Infrared
or Wired
control
Dry
mode
Sleep
mode
Timer
Auto
Sweep
Auto
Restart
Turbo
mode
Thin
profile
Quiet
4 Way
Air Flow
Floor/
Ceiling
Ducted
Installation
Air
Filter
Low
Ambient
Kit
11
Range Capacities
2.0
3.0
2.5
High Wall
Inverter R32
2.7
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
3.5
5.3
2.6
3.5
5.3
7.0
2.6
3.5
5.3
7.0
7.5
8.0
8.5
9.0
10.0
9.5
7.3
Page 16
High Wall
Inverter
Pyrenees
Page 18
High Wall
Inverter
Monte Rosa
Page 20
4.1
Multi
Inverter
5.1 5.3
7.4
8.5
9.7
Page 22
5.3
7.0
8.8
3.5
5.3
7.0
8.8
3.5
5.3
7.0
8.8
3.5
5.3
7.0
3.5
5.3
7.0
3.5
5.3
7.0
3.5
5.3
7.0
Floor/Ceiling
Inverter
Page 26
Cassette
Inverter
Page 28
Blower
Inverter
Page 30
High Wall
On/Off
Monte Rosa
2.6
Page 34
Floor/Ceiling
On/Off
Page 36
Cassette
On/Off
Page 38
Blower
On/Off MSP
Page 40
7.0
Blower
On/Off HSP
Page 42
* ErP documents for product below 12kW available in https://virtualbranch.johnsoncontrols.com/vb/catalog/HVAC-Equipment/6/Minisplits/33
12
YORK® AIR-CONDITIONING PRODUCTS
10.0
10.5
11.0
11.5
12.0
12.5
13.0
13.5
14.0
14.5
15.0
15.5
16.0
16.5
11.8
10.6
12.3
10.6
12.3
10.6
12.3
14.1
15.8
13.8
16.1
14.1
15.8
10.6
14.1
16.1
10.6
14.1
16.1
10.6
14.1
16.1
10.6
14.1
16.4
13
17.0
17.5
18.0
18.5
kW
14
YORK® AIR-CONDITIONING PRODUCTS
Minisplit Inverter Systems
high wall inverter
floor/ceiling inverter
cassette inverter
blower inverter
15
High Wall Inverter
YHKF 09 to 24 ZEEBMHORX
A complete range from 2.7 kW to 7.3 kW
Features
Remote controller
• R32 Refrigerant
• High SEER & SCOP, Class A++
• DC Inverter compressor
• Low noise levels
• Multispeed fan
• Automatic restart
• Automatic air sweep
• LED display
• Two-way draining
• High density filter
• Low Ambient Kit
• Refrigerant leakage detect
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and outdoor units)
• Wireless
• Follow me function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• 5 Fan speeds selection
• Quiet/sleep button
• ON/OFF timer
• Air flow direction setting
• LCD display
• Turbo mode
• Room temperature setting
16
YORK® AIR-CONDITIONING PRODUCTS
High Wall Inverter
YHKF 09 to 24 ZEEBMHORX
Technical features
Set reference
YHKF_ZEEBMHORX
Indoor unit
Sizes
YHKF09XEEBMH-RX
YHKF12XEEBMH-RX
YHKF18XEEBMH-RX
YHKF24XEEBMH-RX
Outdoor unit
Sizes
YHKF09YEEBMHO-X
YHKF12YEEBMHO-X
YHKF18YEEBMHO-X
YHKF24YEEBMHO-X
Cooling capacity
kW
2.7 (1.0~3.2)
3.5 (0.8~4.2)
5.3 (1.7~6.2)
7.3 (2.6~8.4)
Heating capacity
kW
2.9 (0.9~3.7)
3.8 (0.8~4.8)
5.6 (1.1~7.0)
7.6 (1.5~9.4)
Compressor
Type
Rotary
Refrigerant
R32
Power supply
Power input
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.07 ~ 1.23
0.05 ~ 1.60
0.12 ~ 2.39
0.23 - 3.35
heating
kW
0.14 ~ 1.31
0.13 ~ 1.71
0.19 ~ 2.49
0.23 - 3.37
SEER
7.1
7.5
6.7
6.9
SCOP
4.0
4.2
4.0
4.0
cooling
A++
A++
A++
A++
heating
A+
A+
A+
A+
Energy Class
Indoor airflow
m3/h
521 / 429 / 259
539 / 478 / 294
750 / 505 / 420
1050 / 750 / 560
Sound pressure Indoor (H/M/L)
at 1 m
Outdoor
dB(A)
37 / 29.5 / 22
38 / 30 / 22
42 / 33 / 27
46 / 40 / 30
dB(A)
55
55
57
59
H (mm)
290
297
319
335
1 080
Indoor
Dimensions
Outdoor
Net weight
W (mm)
722
802
965
D (mm)
187
189
215
226
H (mm)
555
555
554
700
W (mm)
770
770
800
845
D (mm)
300
300
333
320
Indoor unit
kg
7.4
8.2
9
12
Outdoor unit
kg
26.4
26.5
37
48
Gas
3/8”
3/8”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
3/8”
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
700
800
1 250
1 600
Length
m
25
25
30
50
Height
m
10
10
20
25
18
24
Operating limit - cooling mode
min./max.
-15°C / +50°C
Operating limit - heating mode
min./max.
-15°C / +30°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
17
High Wall Inverter Pyrenees
YHKE 09 to 24 ZEEAMHORX
A complete range from 2.6 kW to 7.0 kW
Features
Remote controller
• High SEER & SCOP, Class A++
• DC Inverter compressor
• Low noise levels
• Multispeed fan
• Automatic restart
• Automatic air sweep
• LED display
• Two-way draining
• High density filter
• Low Ambient Kit
• Refrigerant leakage detect
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and outdoor units)
• Wireless
• Follow me function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• 5 Fan speeds selection
• Quiet/sleep button
• ON/OFF timer
• Air flow direction setting
• LCD display
• Turbo mode
• Room temperature setting
18
YORK® AIR-CONDITIONING PRODUCTS
High Wall Inverter Pyrenees
YHKE 09 to 24 ZEEAMHORX
Technical features
Set reference
YHKE_ZEEAMHORX
Indoor unit
Sizes
YHKE09XEEAMH-RX
YHKE12XEEAMH-RX
YHKE18XEEAMH-RX
YHKE24XEEAMH-RX
Outdoor unit
Sizes
YHKE09YEEAMHO-X
YHKE12YEEAMHO-X
YHKE18YEEAMHO-X
YHKE24YEEAMHO-X
Cooling capacity
kW
2.6 (1.2~3.3)
3.5 (1.4~4.5)
5.3 (1.8~6.2)
7.0 (2.7~8.1)
Heating capacity
kW
2.9 (0.9~3.8)
3.8 (1.1~4.9)
5.6 (1.4~9.4)
7.9 (2.2~9.3)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.75 (0.09~1.27)
1.13 (0.1~1.74)
1.54 (0.15~2.38)
2.26 (0.23~3.11)
heating
kW
0.75 (0.14~1.34)
1.06 (0.17~1.76)
1.50 (0.22~2.43)
2.32 (0.32~3.32)
SEER
7.4
6.8
6.8
6.6
SCOP
4.2
4.2
4.0
4.0
cooling
A++
A++
A++
A++
heating
A+
A+
A+
A+
Energy Class
Indoor airflow
m3/h
420 / 310 / 240
520 / 460 / 270
750 / 500 / 420
1 060 / 830 / 610
Sound pressure Indoor (H/M/L)
at 1 m
Outdoor
dB(A)
37 / 33 / 23
39 / 35 / 24
42 / 34 / 29
48 / 43 / 32
dB(A)
58
60
62
66
H (mm)
290
297
319
335
1 080
Indoor
Dimensions
Outdoor
Net weight
W (mm)
722
802
965
D (mm)
187
189
215
226
H (mm)
555
554
554
702
W (mm)
770
800
800
845
D (mm)
300
333
333
363
Indoor unit
kg
7.4
8.2
10.7
13
Outdoor unit
kg
26.6
29.1
37.8
48.4
Gas
3/8”
3/8”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
3/8”
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
800
950
1 480
2 000
Length
m
25
25
30
50
Height
m
10
10
20
25
18
24
Operating limit - cooling mode
min./max.
-15°C / +50°C
Operating limit - heating mode
min./max.
-15°C / +30°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
19
High Wall Inverter Monte Rosa
YHKE 09 to 24 ZE-MJORX
A complete range from 2.6 kW to 7.0 kW
Features
Remote controller
• High SEER & SCOP, Class A++
• DC Inverter compressor
• Low noise levels
• Multispeed fan
• Automatic restart
• Automatic air sweep
• LED display
• Two-way draining
• High density filter
• Low Ambient Kit
• Refrigerant leakage detect
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and outdoor units)
• Wireless
• Follow me function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• 5 Fan speeds selection
• Quiet/sleep button
• ON/OFF timer
• Air flow direction setting
• LCD display
• Turbo mode
• Room temperature setting
20
YORK® AIR-CONDITIONING PRODUCTS
High Wall Inverter Monte Rosa
YHKE 09 to 24 ZE-MJORX
Technical features
Set reference
YHKE_ZE-MJORX
Indoor unit
Sizes
YHKE09XE-MJ-RX
YHKE12XE-MJ-RX
YHKE18XE-MJ-RX
YHKE24XE-MJ-RX
Outdoor unit
Sizes
YHKE09YE-MJO-X
YHKE12YE-MJO-X
YHKE18YE-MJO-X
YHKE24YE-MJO-X
Cooling capacity
kW
2.6 (1.0~3.2)
3.5 (1.1~4.1)
5.3 (1.8~6.1)
7.0 (2.7~7.9)
Heating capacity
kW
2.9 (0.8~3.4)
3.8 (0.9~4.2)
5.6 (1.4~6.7)
7.3 (1.6~8.8)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.1 ~ 1.24
0.1 ~ 1.58
0.14 ~ 2.36
0.24 ~ 3.03
heating
kW
0.12 ~ 1.20
0.13 ~ 1.51
0.2 ~ 2.41
0.26 ~ 3.14
SEER
6.2
6.1
6.4
6.1
SCOP
4.0
4.0
4.0
4.0
cooling
A++
A++
A++
A++
heating
A+
A+
A+
A+
Power input
Energy Class
Indoor airflow
m3/h
420 / 320 / 270
570 / 470 / 370
840 / 680 / 540
980 / 800 / 640
Sound pressure Indoor (H/M/L)
at 1 m
Outdoor
dB(A)
40 / 34 / 29.5
41 / 36 / 28
47 / 40 / 35
45 / 39 / 34
dB(A)
55.5
56
56
60
H (mm)
285
285
302
327
W (mm)
715
805
957
1 040
D (mm)
194
194
213
220
H (mm)
555
555
554
702
Outdoor
W (mm)
770
770
800
845
D (mm)
300
300
333
363
Indoor unit
kg
6.8
7.2
9.5
11.9
Outdoor unit
kg
25.2
25.5
37.8
48.4
Indoor
Dimensions
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
Gas
3/8”
3/8”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
3/8”
g
800
800
1 480
1 850
Length
m
25
25
30
50
Height
m
10
10
20
25
18
24
Operating limit - cooling mode
min./max.
-15°C / +50°C
Operating limit - heating mode
min./max.
-15°C / +30°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
21
Multi Inverter Free Indoor Units
YJU_YH 014 to 045
A complete range from 4.1 kW to 11.8 kW
Features
Remote controller
• High SEER & SCOP, Class A or more
• DC inverter compressor
• Free match indoor/outdoor
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• Valve protection cover
• Single general valve design (25K/30K/34K)
• Blue fin protection (indoor and outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• On/Off timer
• Turbo cool/heat settings
• Fan speed selection
• Air flow direction setting
• LED display
• Lock button
Indoor units
22
YORK® AIR-CONDITIONING PRODUCTS
Multi Inverter Free Indoor Units
YJU_YH 014 to 045
Technical features Outdoor units
Model
YJU_YH
Outdoor units
Sizes
YJU2YH014
YJU2YH018
YJU3YH019
YJU4YH025
YJU4YH030
YJU5YH034
Indoor units
number
2 indoor units
2 indoor units
3 indoor units
4 indoor units
4 indoor units
5 indoor units
YJU5YH045
5 indoor units
Cooling capacity
kW
4.1 (1.2 ~ 4.5)
5.1 (1.3 ~ 5.8)
5.3 (1.5 ~ 7.0)
7.4 (1.5 ~ 9.0)
8.5 (1.5 ~ 9.8)
9.7 (1.5 ~ 11.0)
11.8 (1.5 ~ 13.4)
Heating capacity
kW
4.4 (1.5 ~ 5.0)
5.8 (1.9 ~ 6.6)
6.3 (1.8 ~ 8.1)
8.3 (1.8 ~ 9.5)
9.5 (1.8 ~ 10.5)
10.3 (1.8 ~ 11.5)
12.2 (1.8 ~ 14.0)
Compressor
Type (Nb)
2.94
Rotary Inverter (1)
Refrigerant
R410A
Location of expansion device
Power supply
Outdoor unit
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
1.17
1.47
1.39
2.10
2.41
2.94
heating
kW
1.12
1.41
1.52
2.06
2.43
2.85
2.85
3.9
3.5
3.8
3.5
3.5
3.3
3.09
SEER
5.56
5.59
6.6
6.6
6.6
6.6
6.6
COP
4.03
3.74
4.30
3.80
4.00
3.90
3.80
3.8
4.0
4.0
4.0
4.0
4.0
3.8
A
A
A++
A++
A++
A++
A++
Power input
EER
SCOP
Energy Class
cooling
heating
Airflow (outdoor unit)
m3/h
Sound pressure level
Dimensions
outdoor unit
A
A+
A+
A+
A+
A+
A
1 900
2 900
2 000
3 500
4 000
4 000
4 200
dB(A)
62
63
52
56
56
58
60
Height
mm
540
688
688
840
840
840
830
Width
mm
780
810
886
948
948
948
1 008
Depth
mm
270
288
289
340
340
340
447
kg
38
43.5
51
74
76
77
90
Net weight outdoor unit
Type of connection
Piping
Max pipe run *
Flare
Gas
3/8”
3/8”
3 x 3/8”
3 x 3/8” + 1 x 1/2”
3 x 3/8” + 1 x 1/2”
4 x 3/8” + 1 x 1/2”
3 x 3/8” + 2 x 1/2”
Liquid
1/4”
1/4”
3 x 1/4”
4 x 1/4”
4 x 1/4”
5 x 1/4”
5 x 1/4”
Length
m
30
30
50
70
70
80
100
Height
m
15
15
15
15
15
15
15
g
1 200
1 400
2 000
3 100
3 200
3 400
3 200
Diameter
Refrigerant charge
Operating limits cooling mode min/max
-10°C / +46°C
Operating limits heating mode min/max
-15°C / +24°C
* values for all the system (all indoor units connected)
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge (each indoor unit)
Manufacturer reserves the rights to change specifications without prior notice.
23
Indoor units technical features
High Wall
Features
• Automatic restart
• Automatic air sweep
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
07 *
kW
2.0
kW
2.2
V/Ph/Hz
m3/h
600
H/M/L
dB(A)
38 / 33 / 26
H/W/D
mm
280 / 855 / 204
kg
10
Type of connection
Gas
3/8”
Diameter
Liquid
1/4”
09 *
2.7
2.8
600
38 / 33 / 26
280 / 855 / 204
10
3/8”
1/4”
YJHMXH
12
3.6
3.7
230 / 1 / 50 + E
650
39 / 34 / 27
280 / 855 / 204
10
Flare
3/8”
1/4”
18
5.2
5.8
24
7.0
7.5
900
44 / 40 / 35
322 / 997 / 235
13
1 200
47 / 43 / 37
336 / 1115 / 248
16
1/2”
1/4”
5/8”
1/4”
Floor / Ceiling
Features
• Floor/Ceiling
• Automatic air sweep
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
H/M/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
YHFMXH
18
5.0
5.5
230 / 1 / 50 + E
800
44 / 41 / 36
665 / 990 / 199
28.3
Flare
1/2”
1/4”
12
3.5
3.9
650
41 / 37 / 33
665 / 990 / 199
26.3
3/8”
1/4”
24
6.3
7.1
800
48 / 45 / 42
665 / 990 / 199
28.3
5/8”
3/8”
Cassette
YHKMXH
Features
• Condensate pump
included
• Automatic air sweep
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions unit
Dimensions panel
Net weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
H/M/L
dB(A)
H/W/D
mm
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
09 *
2.6
2.9
620
40 / 36 / 32
260 / 570 / 570
60 / 700 / 700
17
3/8”
1/4”
12
3.5
3.7
18
5.0
5.2
230 / 1 / 50 + E
620
680
40 / 36 / 32
42 / 37 / 35
260 / 570 / 570
260 / 570 / 570
60 / 700 / 700
60 / 700 / 700
18.5
18.5
Flare
3/8”
1/2”
1/4”
1/4”
24
6.5
7.1
1 300
46 / 44 / 39
240 / 840 / 840
60 / 950 / 950
26.8
5/8”
3/8”
Slim duct
YH3MXH
Features
• Slim size
• Air filter included
• Wired control included
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Static pressure
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
Pa
H/M/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
09 *
2.7
2.8
530
30
33 / 29 / 26
185 / 850 / 420
15.9
3/8”
1/4”
12
3.5
3.9
18
5.0
6.4
230 / 1 / 50 + E
600
900
30
30
35 / 31 / 27
36 / 30 / 26
185 / 850 / 420
185 / 1 170 / 420
15.9
25
Flare
3/8”
1/2”
1/4”
1/4”
24
7.1
7.2
1 100
30
39 / 32 / 29
185 / 1 170 / 420
27
5/8”
3/8”
Duct
YHDMXH
Features
• Air filter included
• Wired control included
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Static pressure
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
Pa
H/M/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
09 *
2.5
2.9
550
25
37 / 34 / 31
220 / 610 / 483
14
3/8”
1/4”
24
12
3.5
4.0
18
5.0
5.5
230 / 1 / 50 + E
550
850
25
25
37 / 34 / 31
41 / 35 / 32
220 / 610 / 483
220 / 1 090 / 500
14
23
Flare
3/8”
1/2”
1/4”
1/4”
24
6.8
7.1
1 200
25
45 / 41 / 37
220 / 1 090 / 500
24.5
5/8”
3/8”
YORK® AIR-CONDITIONING PRODUCTS
Indoor unit combinations
YJU2YH014 (2x1)
YJU2YH018 (2x1)
Number connecting units
2x1
7+7
7+9
7+12
Number connecting units
2x1
9+9
9+12
7+7
7+9
7+12
9+9
9+12
12+12
YJU3YH019 (3x1)
Number connecting units
2x1
3x1
7+7
7+9
7+12
7+18
9+9
9+12
9+18
12+12
12+18
7+7+7
7+7+9
7+7+12
7+7+18
7+9+9
7+9+12
7+12+12
9+9+9
9+9+12
9+12+12
YJU4YH025 (4x1)
Number connecting units
3x1
2x1
7+18
7+24
9+18
9+24
12+12
12+18
12+24
18+18
18+24
7+7+9
7+7+12
7+7+18
7+7+24
7+9+9
7+9+12
7+9+18
7+12+12
4x1
7+12+18
9+9+9
9+9+12
9+9+18
9+12+12
12+12+12
12+12+18
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+9+9
7+7+9+12
7+9+9+9
7+9+9+12
9+9+9+9
9+9+9+12
YJU4YH030 (4x1)
Number connecting units
3x1
2x1
7+24
9+18
9+24
12+18
12+24
18+18
18+24
24+24
7+7+18
7+7+24
7+9+12
7+9+18
7+9+24
7+12+12
7+12+18
7+12+24
9+9+9
9+9+12
4x1
9+9+18
9+9+24
9+12+12
9+12+18
9+12+24
12+12+12
12+12+18
12+12+24
12+18+18
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+7+24
7+7+9+9
7+7+9+12
7+7+9+18
7+7+9+24
7+7+12+12
7+7+12+18
7+9+9+9
7+9+9+12
7+9+9+18
7+9+12+12
7+12+12+12
9+9+9+9
9+9+9+12
9+9+12+12
9+9+12+18
9+12+12+12
12+12+12+12
YJU5YH034 (5x1)
2x1
7+18
7+24
9+18
9+24
12+18
12+24
18+18
18+24
24+24
Number connecting units
4x1
3x1
7+7+12
7+7+18
7+7+24
7+9+9
7+9+12
7+9+18
7+9+24
7+12+12
7+12+18
7+12+24
9+9+9
9+9+12
9+9+18
9+9+24
9+12+12
9+12+18
9+12+24
12+12+12
12+12+18
12+12+24
12+18+18
18+18+18
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+7+24
7+7+9+9
7+7+9+12
7+7+9+18
7+7+9+24
7+7+12+12
7+7+12+18
5x1
7+9+9+9
7+9+9+12
7+9+9+18
7+9+12+12
7+12+12+12
9+9+9+9
9+9+9+12
9+9+9+18
9+9+12+12
9+12+12+12
12+12+12+12
7+7+7+7+7
7+7+7+7+9
7+7+7+7+12
7+7+7+9+9
7+7+7+9+12
7+7+7+12+12
7+7+9+9+9
7+7+9+9+12
7+9+9+9+9
9+9+9+9+9
9+9+9+9+12
9+9+9+12+12
YJU5YH045 (5x1)
2x1
7+18
7+24
9+18
9+24
12+18
12+24
18+18
18+24
24+24
Number connecting units
4x1
3x1
7+7+12
7+7+18
7+7+24
7+9+9
7+9+12
7+9+18
7+9+24
7+12+12
7+12+18
7+12+24
9+9+9
9+9+12
9+9+18
9+9+24
9+12+12
9+12+18
9+12+24
12+12+12
12+12+18
12+12+24
12+18+18
12+18+24
18+18+18
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+7+24
7+7+9+9
7+7+9+12
7+7+9+18
7+7+9+24
7+7+12+12
7+7+12+18
7+7+12+24
7+9+9+9
7+9+9+12
25
5x1
7+9+9+18
7+9+9+24
7+9+12+12
7+12+12+12
9+9+9+9
9+9+9+12
9+9+9+18
9+9+9+24
9+9+12+12
9+9+12+18
9+12+12+12
9+12+12+18
9+12+12+24
7+7+7+7+7
7+7+7+7+9
7+7+7+7+12
7+7+7+7+24
7+7+7+9+9
7+7+7+9+12
7+7+7+9+18
7+7+7+9+24
7+7+7+12+12
7+7+7+12+18
7+7+7+12+24
7+7+9+9+9
7+7+9+9+12
7+7+9+9+18
7+7+9+9+24
9+9+9+9+9
9+9+9+9+12
9+9+9+9+18
9+9+9+12+12
9+9+9+12+18
Floor/Ceiling Inverter
YFKE 18 to 55
A complete range from 5.3 kW to 15.8 kW
Features
Remote controller
• High SEER & SCOP, Class A++
• Inverter DC compressor and fan motor
• Washable filter
• Convertible - floor or ceiling
• Automatic restart
• Automatic air sweep
• Horizontal and vertical air sweep function
• Different swing angle design for cooling and heating
• 3D airflow
• Low Ambient Kit
• Service valve protection cover
• Rustproof casing
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• Wireless
• Follow me function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
• Turbo mode
26
YORK® AIR-CONDITIONING PRODUCTS
Floor/Ceiling Inverter
YFKE 18 to 55
Technical features
Set reference
YFKE_ZEEBMORX
Indoor unit
Sizes
YFKE 18
YFKE 24
YFKE 30
YFKE 36
YFKE 42
YFKE 48
YFKE 55
Outdoor unit
Sizes
YUKE 18
YUKE 24
YUKE 30
YUKE 36
YUKE 42
YUKE 48
YUKE 55
Cooling capacity
kW
5.3 (0.8 - 36.2)
7.0 (1.20 - 8.21)
8.8 (2.1 - 10.6)
10.6 (2.9 - 12.0)
12.3 (3.2 - 13.2)
14.1 (4.1 - 16.4)
15.8 (5.0 - 18.1)
Heating capacity
kW
5.7 (0.9 - 7.0)
7.0 (1.20 - 8.65)
9.4 (2.1 - 10.8)
11.1 (2.6 - 13.2)
13.5 (3.0 - 14.7)
16.4 (4.4 - 18.5)
18.2 (5.3 - 20.5)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
230 / 1 / 50
230 / 1 / 50 or 400 / 3 / 50
400 / 3 / 50
cooling
kW
1630 (270 - 2365)
2285 (400 - 3155)
2960 (690 - 4055)
4060 (975 - 4620)
4230 (1070 - 5070)
5190 (1370 - 6310)
6060 (1660 - 6965)
heating
kW
5645 (1760 - 7320)
1460 (255 - 2510)
1900 (400 - 3090)
2475 (690 - 3870)
2985 (880 - 4690)
3540 (945 - 5000)
4810 (1465 - 6590)
SEER
6.5
6.1
6.1
6.3
6.1
6.1
6.1
SCOP
4.0
4.0
4.0
4.0
4.0
4.0
4.0
cooling
A++
A++
A++
A++
A++
A++
A++
heating
A+
A+
A+
A+
A+
A+
A+
m3/h
900 / 800 / 700
1180 / 1050 / 850
1650 / 1450 / 1250
2048 / 1767 / 1403
2271 / 1886 / 1394
2100 / 1800 / 1400
2250 / 1660 / 1280
Indoor (H/M/L)
dB(A)
44 / 39 / 34
53 / 48 / 42
54 / 49 / 44
52 / 46 / 40
55 / 49 / 43
52 / 46 / 41
55 / 50 / 45
Outdoor
dB(A)
56.5
60.5
59.5
61
62.5
65
62.5
H (mm)
675
675
675
675
675
675
675
W (mm)
1 068
1 068
1 280
1 650
1 650
1 650
1 650
Energy Class
Indoor airflow
Sound pressure
at 1 m
Indoor
D (mm)
235
235
235
235
235
235
235
H (mm)
554
702
810
810
810
1 333
1 333
W (mm)
800
845
946
946
946
952
952
D (mm)
333
363
410
410
410
410
410
Indoor unit
kg
25.8
25
31
40.3
40.5
38.2
40.5
Outdoor unit
kg
35.5
49
62.9
67.2
70.5
95.1
112.8
Gas
1/2”
5/8”
5/8”
5/8”
5/8”
5/8”
5/8”
Liquid
1/4”
3/8”
3/8”
3/8”
3/8”
3/8”
3/8”
Dimensions
Outdoor
Net weight
Type of connection
Piping
Pipe run
Diameter
Flare
Length
m
30
50
50
65
65
65
65
Height
m
20
25
25
30
30
30
30
42
48
55
Operating limits - cooling mode
min/max
-15°C / +50°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Size 36, 42 and 48: Values for single phase models.
Accessories
Sizes
18
24
30
36
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
27
Cassette Inverter
YTKE 12 to 18 BZE / YKKE 18 to 55 BZE(O)
A complete range from 3.5 kW to 16.1 kW
Features
Remote controller
• High SEER & SCOP, Class A++ mainly
• Inverter DC compressor and fan motor
• Special low noise fan design
• Washable filter
• Fresh air intake
• Built-in drain pump
• Automatic restart
• Automatic air sweep
• Low Ambient Kit
• Different swing angle design for cooling and heating
• Service valve protection cover
• Rustproof casing
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• Wireless
• Follow me function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
• Turbo mode
28
YORK® AIR-CONDITIONING PRODUCTS
Cassette Inverter
YTKE 12 to 18 BZE / YKKE 18 to 55 BZE(O)
Technical features
Set reference
YTKE_BZEEBMORX
YKKE_BZE(O)
Indoor unit
Sizes
YTKE 12
YTKE 18
YKKE 18
YKKE 24
YKKE 30
YKKE 36
YKKE 42
YKKE 48
YKKE 55
Outdoor unit
Sizes
YUKE 12
YUKE 18
YUKE 18
YUKE 24
YUKE 30
YUKE 36
YUKE 42
YUKE 48
YUKE 55
Cooling capacity
kW
3.5 (0.6~4.4)
5.3 (0.8~6.2)
5.3 (0.8~6.2)
7.0 (1.2~8.2)
8.8 (2.1~10.6) 10.6 (2.9~12.0) 12.3 (3.2~13.2) 13.8 (4.0~16.1) 16.1 (5.0~18.5)
Heating capacity
kW
4.1 (1.0~5.1)
5.6 (0.9~7.0)
5.7 (0.9~7.0)
7.0 (1.2~8.7)
9.1 (2.1~10.5) 11.1 (2.6~13.2) 13.5 (2.9~14.7) 15.5 (4.2~17.6) 18.2 (5.3~20.5)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50
230 / 1 / 50 or 400 / 3 / 50
400 / 3 / 50
cooling
kW
0.96
1.63
1.68
2.17
2.76
4.06
4.09
5.15
6.39
heating
kW
0.99
1.50
1.46
1.90
2.38
3.08
3.53
4.55
5.73
SEER
6.1
6.3
6.3
6.1
6.1
6.1
5.6
5.6
5.6
SCOP
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
cooling
A++
A++
A++
A++
A++
A++
A+
A+
A+
heating
A+
A+
A+
A+
A+
A+
A+
A+
A+
Power input
Energy Class
Indoor airflow (H/M/L)
m3/h
650/530/450
660/550/490
1000/800/700
Sound pressure Indoor (H/M/L)
at 1 m
Outdoor
dB(A)
42 / 38 / 34
46 / 42 / 38
46 / 41 / 37
46 / 42 / 39
53 / 48 / 44
53 / 50 / 47
54 / 51 / 48
53 / 49 / 45
52 / 49 / 46
dB(A)
57
56.5
56.5
60.5
59.5
61
62.5
65
62.5
H (mm)
260
260
205
257
257
257
287
287
287
W (mm)
570
570
840
840
840
840
840
840
840
Indoor
Dimensions
Outdoor
Net weight
1450/1250/1100 1700/1460/1300 1900/1750/1460 1850/1600/1400 1850/1600/1400 1900/1650/1450
D (mm)
570
570
840
840
840
840
840
840
840
H (mm)
554
554
554
702
810
810
810
1 333
1 333
W (mm)
800
800
800
845
946
946
946
952
952
D (mm)
333
333
333
363
410
410
410
410
410
50 / 647 / 647 50 / 647 / 647 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950 55 / 950 / 950
Panel H / W / D
mm
Indoor unit
kg
18.5
19
26.3
29
31.5
30.6
31.1
32
36
Outdoor unit
kg
34.5
35.5
35.5
49
62.9
67.2
70.5
95.1
112.8
Gas
3/8”
1/2”
1/2”
5/8”
5/8”
5/8”
5/8”
5/8”
5/8”
Liquid
1/4”
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
3/8”
3/8”
Type of connection
Piping
Pipe run
Diameter
Flare
Length
m
25
30
30
50
50
65
65
65
65
Height
m
10
20
20
25
25
30
30
30
30
36
42
48
55
Operating limits - cooling mode
min/max
-15°C / +50°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Size 36, 42 and 48: Values for single phase models.
Accessories
Sizes
12
18
18
24
30
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
29
Blower Inverter Medium Static Pressure
YEKE 12 to 55 BZE(O)
A complete range from 3.5 kW to 15.8 kW
Features
Wired control
• High SEER & SCOP, Class A+ or more
• Inverter DC compressor and fan motor
• Washable filter
• Automatic restart
• Condensate pump optional
• Low noise levels
• Wired control
• Low Ambient Kit
• Intelligent defrosting
• Fresh air intake
• Service valve protection cover
• Rustproof casing
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
30
YORK® AIR-CONDITIONING PRODUCTS
Blower Inverter Medium Static Pressure
YEKE 12 to 55 BZE(O)
Technical features
Set reference
YEKE_BZE(O)
Indoor unit
Sizes
YEKE 12
YEKE 18
YEKE 24
YEKE 30
YEKE 36
YEKE 42
YEKE 48
YEKE 55
Outdoor unit
Sizes
YUKE 12
YUKE 18
YUKE 24
YUKE 30
YUKE 36
YUKE 42
YUKE 48
YUKE 55
Cooling capacity
kW
3.5 (0.6~4.4)
5.3 (0.8~6.2)
7.0 (1.2~8.2)
8.8 (2.1~10.6)
10.6 (2.9~12.0)
12.3 (3.2~13.2)
14.1 (4.1~16.4)
15.8 (5.0~18.1)
Heating capacity
kW
3.8 (0.6~5.0)
5.7 (0.9~7.0)
7.0 (1.2~8.7)
9.4 (2.1~10.9)
11.1 (2.6~13.2)
13.5 (2.9~14.7)
16.1 (4.3~18.1)
18.2 (5.3~20.5)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
230 / 1 / 50
230 / 1 / 50 or 400 / 3 / 50
400 / 3 / 50
cooling
kW
1.03
1.68
2.28
2.87
3.96
4.09
5.11
5.25
heating
kW
0.95
1.46
1.90
2.46
2.92
3.53
4.35
5.03
SEER
6.1
6.5
6.1
6.1
6.3
5.6
6.1
6.1
SCOP
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
cooling
A++
A++
A++
A++
A++
A+
A++
A++
heating
A+
A+
A+
A+
A+
A+
A+
A+
680 / 580 / 450
1050 / 900 / 780
Energy Class
Indoor airflow
m3/h
External static pressure
Sound pressure
at 1 m
0 / 100
0 / 100
0 / 100
0 / 100
0 / 100
0 / 100
0 / 100
44 / 40 / 37
46 / 42 / 38
50 / 48 / 44
48 / 45 / 40
50 / 47 / 44
51 / 48 / 45
50 / 47 / 45
dB(A)
57
56.5
60.5
59.5
61
62.5
65
62.5
H (mm)
210
270
270
270
300
300
300
300
W (mm)
700
920
920
1 140
1 200
1 200
1 200
1 200
dB(A)
Outdoor
D (mm)
635
635
635
775
865
865
865
865
H (mm)
554
554
702
810
810
810
1 333
1 333
W (mm)
800
800
845
946
946
946
952
952
D (mm)
333
333
363
410
410
410
410
410
Indoor unit
kg
18.4
26.9
28
35
45
43.4
43.2
43.1
Outdoor unit
kg
34.5
35.5
49
62.9
67.2
70.5
95.1
112.8
Gas
3/8”
1/2”
5/8”
5/8”
5/8”
5/8”
5/8”
5/8”
Liquid
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
3/8”
3/8”
Dimensions
Outdoor
Net weight
0 / 45
42 / 38 / 35
Pa
Indoor (H/M/L)
Indoor
1360 / 1200 / 970 1580 / 1400 / 1100 1750 / 1500 / 1280 2200 / 1900 / 1600 2200 / 1900 / 1600 2200 / 1900 / 1600
Type of connection
Piping
Pipe run
Diameter
Flare
Length
m
25
30
50
50
65
65
65
65
Height
m
10
20
25
25
30
30
30
30
36
42
48
55
Operating limits - cooling mode
min/max
-15°C / +50°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Size 36, 42 and 48: Values for single phase models.
Accessories
Sizes
12
18
24
30
Condensate pump
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
31
32
YORK® AIR-CONDITIONING PRODUCTS
Minisplit On/Off Systems
high wall on/off
floor/ceiling on/off
cassette on/off
blower on/off
33
High Wall On/Off Monte Rosa
YHGE 09 to 24 ZE--MJORX
A complete range from 2.6 kW to 7.0 kW
Features
Remote controller
• Low noise levels
• Multi-speed fan
• Automatic restart
• Automatic air sweep
• LED display
• 3-Minute protection
• Self diagnosis
• Refrigerant leakage detect
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and outdoor units)
• Wireless
• Follow me function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• 5 Fan speeds selection
• Quiet/sleep button
• ON/OFF timer
• Air flow direction setting
• LCD display
• Turbo mode
• Room temperature setting
34
YORK® AIR-CONDITIONING PRODUCTS
High Wall On/Off Monte Rosa
YHGE 09 to 24 ZE--MJORX
Technical features
Set reference
YHGE_ZE--MJORX
Indoor unit
Sizes
YHGE09XE--MJ-RX
YHGE12XE--MJ-RX
YHGE18XE--MJ-RX
YHGE24XE--MJ-RX
Outdoor unit
Sizes
YHGE09YE--MJO-X
YHGE12YE--MJO-X
YHGE18YE--MJO-X
YHGE24YE--MJO-X
Cooling capacity
kW
2.6
3.5
5.3
7.0
Heating capacity
kW
2.8
3.8
5.6
7.3
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.82
1.09
1.64
2.50
heating
kW
0.77
1.05
1.54
2.28
EER
3.21
3.21
3.21
2.81
COP
3.61
3.61
3.61
3.21
cooling
A
A
A
C
heating
A
A
A
C
Power input
Energy Class
Indoor airflow
m3/h
510 / 380 / 338
568 / 440 / 352
820 / 665 / 543
1 000 / 796 / 640
Sound pressure Indoor (H/M/L)
at 1 m
Outdoor
dB(A)
40 / 33 / 26
41 / 36 / 31
43 / 38 / 33
47 / 40 / 34
dB(A)
55.5
56
56
60
H (mm)
285
285
302
327
W (mm)
715
805
957
1 040
D (mm)
194
194
213
220
H (mm)
550
555
555
702
Outdoor
W (mm)
700
770
770
845
D (mm)
270
300
300
363
Indoor unit
kg
6.8
7.2
9.5
11.9
Outdoor unit
kg
26.4
30
35.8
48.8
Indoor
Dimensions
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
Gas
3/8”
1/2”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
3/8”
1 750
g
730
740
1 150
Length
m
20
20
25
25
Height
m
8
8
10
10
18
24
Operating limit - cooling mode
min./max.
+18°C / +43°C
Operating limit - heating mode
min./max.
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
35
Floor/Ceiling On/Off
YFGE 12 to 55 BZE(O)
A complete range from 3.5 kW to 16.1 kW
Features
Remote controller
• Convertible - floor or ceiling
• Washable filter
• High velocity air flow
• Automatic restart
• Automatic air sweep
• Horizontal and vertical air sweep function
• Different swing angle design for cooling and heating
• 2-way drainage
• Service valve protection cover
• Rustproof casing
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• Wireless
• Follow me function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
• Turbo mode
36
YORK® AIR-CONDITIONING PRODUCTS
Floor/Ceiling On/Off
YFGE 12 to 55 BZE(O)
Technical features
Set reference
YFGE_BZE--MO(S)RX
Indoor unit
Sizes
YFGE 12
YFGE 18
YFGE 24
YFGE 36
YFGE 48
YFGE 55
Outdoor unit
Sizes
YUGE 12
YUGE 18
YUGE 24
YUGE 36
YUGE 48
YUGE 55
Cooling capacity
kW
3.5
5.3
7.0
10.6
14.1
16.1
Heating capacity
kW
3.8
5.7
7.6
11.6
15.2
17.6
Compressor
Type
Rotary
Scroll
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50
400 / 3 / 50
cooling
kW
1.25
1.88
2.63
3.98
5.45
6.40
heating
kW
1.28
1.73
2.45
3.70
5.25
5.88
EER
2.80
2.80
2.67
2.65
2.58
2.52
COP
2.98
3.22
3.11
3.13
2.90
3.03
Power input
Energy Class
cooling
C
C
D
D
E
E
heating
D
C
D
D
D
D
m3/h
620 / 500 / 400
1 150 / 950 / 800
1 250 / 1 050 / 900
1 750 / 1 400 / 1 250
1 750 / 1 400 / 1 250
2 300 / 1 800 / 1 120
Indoor (H/M/L)
dB(A)
37 / 33 / 30
53 / 48 / 43
54 / 49 / 43
53 / 48 / 44
53 / 48 / 44
55 / 49 / 46
Outdoor
dB(A)
59
62
62
61
63
63
H (mm)
675
675
675
675
675
675
W (mm)
1 068
1 068
1 068
1 285
1 285
1 650
D (mm)
235
235
235
235
235
235
H (mm)
555
555
702
965
1 170
1 170
Indoor airflow
Sound pressure
at 1 m
Indoor
Dimensions
W (mm)
770
770
845
990
900
900
D (mm)
300
300
363
345
350
350
Indoor unit
kg
23.6
24
24.6
29
31
39
Outdoor unit
kg
30.5
36.5
52.7
85
93.2
97
Outdoor
Net weight
Type of connection
Piping
Diameter
Pipe run
Flare
Gas
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
Length
m
18
25
25
30
50
50
Height
m
8
15
15
20
25
25
36
48
55
Operating limits - cooling mode
min/max
+18°C / +43°C
Operating limits - heating mode
min/max
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
12
18
24
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
37
Cassette On/Off
YTGE 12 to 18 BZE / YKGE 18 to 55 BZE(O)
A complete range from 3.5 kW to 16.1 kW
Features
Remote controller
• 360° Air outlet
• Low noise
• Washable air filter
• Fresh air intake
• Built-in drain pump
• Automatic restart
• Automatic air sweep
• Different swing angle design for cooling and heating
• Service valve protection cover
• Rustproof casing
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• Wireless
• Follow me function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
• Turbo mode
38
YORK® AIR-CONDITIONING PRODUCTS
Cassette On/Off
YTGE 12 to 18 BZE / YKGE 18 to 55 BZE(O)
Technical features
Set reference
YTGE_BZE
YKGE_BZE(O)
Indoor unit
Sizes
YTGE 12
YTGE 18
YKGE 18
YKGE 24
YKGE 36
YKGE 48
YKGE 55
Outdoor unit
Sizes
YUGE 12
YUGE 18
YUGE 18
YUGE 24
YUGE 36
YUGE 48
YUGE 55
Cooling capacity
kW
3.5
5.3
5.3
7.0
10.6
14.1
16.1
Heating capacity
kW
3.8
5.7
5.7
7.6
11.7
15.2
17.6
Compressor
Type
Rotary
Scroll
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
400 / 3 / 50
cooling
kW
1.25
1.84
1.99
2.60
3.98
5.19
heating
kW
1.46
1.90
1.74
2.40
3.60
4.76
5.92
2.80
2.80
2.65
2.71
2.65
2.71
2.59
2.97
EER
6.20
2.89
3.24
3.20
3.18
3.25
3.20
cooling
C
C
D
D
D
D
E
heating
D
C
D
D
C
D
D
COP
Energy Class
230 / 1 / 50
Indoor airflow
m3/h
560 / 550 / 430
810 / 650 / 530
900 / 750 / 600
Sound pressure Indoor (H/M/L)
at 1 m
Outdoor
dB(A)
42 / 38 / 36
48 / 41 / 36
43 / 40 / 35
50 / 45 / 41
51 / 47 / 43
53 / 48 / 44
dB(A)
59
62
62
62
61
63
63
H (mm)
260
260
205
205
245
245
300
W (mm)
570
570
840
840
840
840
840
D (mm)
570
570
840
840
840
840
840
H (mm)
555
555
555
702
965
1 170
1 170
900
Indoor
Dimensions
Outdoor
Net weight
770
770
770
845
990
900
D (mm)
300
300
300
363
345
350
350
50 / 647 / 647
50 / 647 / 647
55 / 950 / 950
55 / 950 / 950
55 / 950 / 950
55 / 950 / 950
55 / 950 / 950
Panel H / W / D
mm
Indoor unit
kg
18.8
19
27
27.1
30
32
37
Outdoor unit
kg
30.5
36.5
36.5
52.7
85
93.2
97
Gas
1/2”
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
Diameter
Pipe run
51 / 47 / 42
W (mm)
Type of connection
Piping
1200 / 1050 / 900 1800 / 1600 / 1400 1900 / 1600 / 1400 1800 / 1480 / 1280
Flare
Length
m
18
25
25
25
30
50
50
Height
m
8
15
15
15
20
25
25
36
48
55
Operating limits - cooling mode
min/max
+18°C / +43°C
Operating limits - heating mode
min/max
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
12
18
18
24
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
39
Blower On/Off Medium Static Pressure
YEGE 12 to 55 BZE(O)
A complete range from 3.5 kW to 16.1 kW
Features
Wired control
• Washable air filter
• High velocity air flow
• Automatic restart
• Condensate pump optional
• Low noise levels
• Wired control
• Reserved remote on-off and alarm ports
• Wireless controller optional
• 3-Minute protection
• Service valve protection cover
• Rustproof casing
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
40
YORK® AIR-CONDITIONING PRODUCTS
Blower On/Off Medium Static Pressure
YEGE 12 to 55 BZE(O)
Technical features
Set reference
YEGE_BZE(O)--MO(S)WX
Indoor unit
Sizes
YEGE 12
YEGE 18
YEGE 24
YEGE 36
YEGE 48
YEGE 55
Outdoor unit
Sizes
YUGE 12
YUGE 18
YUGE 24
YUGE 36
YUGE 48
YUGE 55
Cooling capacity
kW
3.5
5.3
7.0
10.6
14.1
16.1
Heating capacity
kW
3.8
5.7
7.6
11.7
16.1
17.6
Compressor
Type
Rotary
Scroll
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
kW
1.25
1.97
2.65
3.82
5.24
heating
kW
1.31
1.76
2.50
3.65
4.52
5.18
2.80
2.69
2.65
2.76
2.68
2.59
3.39
2.91
3.16
3.05
3.21
3.56
C
D
D
D
D
E
heating
D
D
D
C
B
C
624 / 485 / 400
816 / 546 / -
1 260 / 808 / -
1 848 / 1 106 / -
2 282 / 1 439 / -
2 275 / - / -
0 - 60
0 - 60
0 - 80
0 - 80
0 - 100
0 - 120
40 / 36 / 32
43 / 37 / 36
45 / 40 / 38
48 / 40 / 37
50 / 45 / 40
47 / 40 / 38
Indoor airflow
m3/h
External static pressure
Pa
Indoor (H/M/L)
dB(A)
Outdoor
dB(A)
59
62
62
61
63
63
H (mm)
210
210
270
270
300
300
W (mm)
700
920
920
1 140
1 200
1 200
D (mm)
635
635
635
795
795
865
H (mm)
555
555
702
965
1 170
1 170
Indoor
Dimensions
W (mm)
770
770
845
990
900
900
D (mm)
300
300
363
345
350
350
Indoor unit
kg
18.3
24
26.5
36
44.5
47
Outdoor unit
kg
30.5
36.5
52.7
85
93.2
97
Outdoor
Net weight
Type of connection
Piping
Diameter
Pipe run
6.22
cooling
COP
Sound pressure
at 1 m
400 / 3 / 50
cooling
EER
Energy Class
230 / 1 / 50
Flare
Gas
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
Length
m
18
25
25
30
50
50
Height
m
8
15
15
20
25
25
36
48
55
Operating limits - cooling mode
min/max
+18°C / +43°C
Operating limits - heating mode
min/max
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
12
18
24
Condensate pump
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
41
Blower On/Off High Static Pressure
YGGE 24 to 55 BZE(O)
A complete range from 5.3 kW to 16.4 kW
Features
Wired control
• Washable air filter
• High velocity air flow
• Automatic restart
• Condensate pump optional
• Low noise levels
• Wired control
• Reserved remote on-off and alarm ports
• Wireless controller optional
• 3-Minute protection
• Service valve protection cover
• Rustproof casing
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
42
YORK® AIR-CONDITIONING PRODUCTS
Blower On/Off High Static Pressure
YGGE 24 to 55 BZE(O)
Technical features
Set reference
YEGE_BZE(O)--MO(S)WX
Indoor unit
Sizes
YEGE 24
YEGE 36
YEGE 48
YEGE 55
Outdoor unit
Sizes
YUGE 24
YUGE 36
YUGE 48
YUGE 55
Cooling capacity
kW
7.0
10.6
14.1
16.4
Heating capacity
kW
7.6
11.7
15.2
18.2
Compressor
Type
Rotary
Scroll
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50
400 / 3 / 50
cooling
kW
2.71
3.88
5.41
6.50
heating
kW
2.27
3.24
4.22
5.30
EER
2.60
2.72
2.60
2.53
COP
3.36
3.61
3.61
3.43
cooling
E
D
E
E
heating
C
A
A
B
1 615 / 1 155 / 989
2 148 / 1 810 / 1 648
2 809 / 2 554 / 2 272
3 150 / 2 809 / 2 554
0 - 120
0 - 169
0 - 200
0 - 200
48 / 42 / 38
53 / 50 / 47
51 / 49 / 46
52 / 50 / 48
Power input
Energy Class
Indoor airflow
m3/h
External static pressure
Pa
Sound pressure
at 1 m
Indoor (H/M/L)
dB(A)
Outdoor
dB(A)
62
61
63
63
H (mm)
270
270
380
380
W (mm)
900
1 100
1 200
1 200
D (mm)
525
525
625
625
H (mm)
702
965
1 170
1 170
W (mm)
845
990
900
900
D (mm)
363
345
350
350
Indoor unit
kg
25
31.3
46
45.9
Outdoor unit
kg
52.7
85
93.2
97
Indoor
Dimensions
Outdoor
Net weight
Type of connection
Piping
Diameter
Pipe run
Flare
Gas
5/8”
3/4”
3/4”
3/4”
Liquid
3/8”
3/8”
3/8”
3/8”
Length
m
25
30
50
50
Height
m
15
20
25
25
48
55
Operating limits - cooling mode
min/max
+18°C / +43°C
Operating limits - heating mode
min/max
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 20°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
24
36
Condensate pump
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
43
44
YORK® AIR-CONDITIONING PRODUCTS
VRF Systems
high efficiency series
amazon standard series
indoor unit types
45
VRF System High Efficiency
YV2VYH 025 to 204
Cooling capacities 25.4 kW to 211.2 kW
VRF System
Comfort – Quality
• Capacities from 25.4 to 211.2 kW
• Operating range of nominal power
(10% - 130 %)
• DC Inverter Scroll Compressor
• Low noise levels
• High Efficiency. EER up to 4.29
• Modular design
• Long piping design up to 1000 m
• Big height difference design: 90 m
• Height difference between indoors: 18 m
• Large indoor unit combinations
• Flexible and quickly installation
• Cooling and heating
• Connection up to 64 indoor units
per refrigeration circuit
(3 outdoor units)
• Complete range in R410A
• Reduced footprint
• Is appropriate particularly for
existing buildings
• Cooling to -5°C to +43°C
(outdoor temperature)
• Heating to -15°C to +24°C
(outdoor temperature)
46
YORK® AIR-CONDITIONING PRODUCTS
YV2VYH Technical features - Single module outdoor unit
Model
Cooling capacity
kW
EER
Heating capacity
kW
COP
YV2VYH025
YV2VYH028
YV2VYH033
YV2VYH040
YV2VYH045
YV2VYH050
YV2VYH056
YV2VYH061
YV2VYH068
25.4
28.9
34.8
41.5
46.4
51.5
57.8
63.7
70.4
4.29
4.00
3.90
3.55
3.47
3.42
3.34
3.18
3.09
28.1
32.4
37.9
45.8
51.1
57.2
63.7
70.1
73.9
4.30
4.19
3.71
3.84
3.82
3.74
3.75
3.73
3.83
Air flow in cooling
m3/h
15 000
15 000
15 000
15 000
15 600
16 200
16 200
16 200
16 200
Sound Pressure Level at 1 m
dB(A)
57
57
59
59,5
61
62
62
62
63
Electrical features
380V-3-50/60Hz
Power supply
Power input “cooling”
kW
5.87
7.00
8.60
11.27
12.97
14.73
16.79
19.37
21.98
Power input “heating”
kW
6.28
7.52
10.12
11.73
13.10
15.12
16.79
18.48
19.08
Compressor
Type
DC Inverter Scroll
2 x DC Inverter Scroll
Dimensions and Weight
Height x Width x Length
mm
Weight
kg
1690x1350x720 1690x1350x720 1690x1350x720 1690x1350x720 1690x1350x720 2048x1350x720 2048x1350x720 2048x1350x720 2048x1350x720
278
278
278
282
324
343
343
369
369
Piping connections
1”
1”
1”
1” 1/4”
1” 1/4”
1” 1/4”
1” 1/4”
1” 1/4”
1” 1/4”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
10
10
10
10
30
33
36
40
Gas
Liquid
Type
Refrigerant charge
R410A
kg
10
10
10
10
10
Piping length / Height difference
Max. piping length farthest indoor unit (m)
190
Max. height difference indoor/outdoor (m)
50
Max. number of indoor units
13
16
20
24
27
Models available to be confirmed as soon as they are launched (estimated Mar’15)
Combination of modular outdoor units
Model
074 080 085 090 095 101 106
Capacity Cooling kW 76.3 83.0
Heating kW 83.7
Maximum indoor units
43
91.6
46
87.9
93.0
112
118
124 130
136 141 146 151
157
162
168
174
180 186
192
198 204
97.9 104.2 109.3 115.6 121.5 128.2 140.0 140.8 144.5 150.6 155.7 162.0 167.1 173.4 179.3 186.0 191.9 198.6 204.5 211.2
96.9 103.0 108.3 114.8 120.9 127.4 133.8 137.6 144.0 147.8 160.2 165.9 172.0 178.5 184.6 191.1 197.5 201.3 207.7 211.5 217.9 221.7
50
53
57
60
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
Appearance
DX-Kit Available for all type of 2-pipe outdoor units
York offers a range of connection kit to connect VRF outdoor units
to third party DX air handling units.
Two models availables:
• YAH1-280A (up to 28 kW)
• YAH1-560A (up to 56 kW)
Manufacturer reserves the rights to change specifications without prior notice.
47
YCZ-G001 Central Controller
Available for all type of outdoor units
• Max. 32 indoor units control.
• Max. 32 outdoor units control.
• On/Off, Mode, Fan speed,
Temperature setting, Swing.
• Individual control, Group control
& Central control (Max. 32 indoor
units)
• Color interface with back light
• Large touch key
• Fahrenheit/Celsius selectable
• Weekly timer
• Unit name & Group name free setting. Four background
available (mall, hotel, office, home)
• Error display
• Together with one IGU05 per outdoor unit
64
Amazon Standard Ambient VRF System
YV2V 010 to 135
Cooling capacities 9 kW to 135 kW
VRF System
Comfort – Quality
• Capacities from 9 to 135 kW
• Operating range of nominal power
(10% - 130 %)
• DC Inverter Scroll Compressor
• Low noise levels
• High Efficiency. EER up to 4.28
• Modular design
• Large indoor unit combinations
• Flexible and quickly installation
• Cooling and heating
• Connection up to 64 indoor units
per refrigeration circuit
(3 outdoor units)
• Complete range in R410A
• Reduced space of ground
• Is appropriate particularly for
existing buildings
• Cooling to -5°C to +43°C
(outdoor temperature)
• Heating to -15°C to +24°C
(outdoor temperature)
48
YORK® AIR-CONDITIONING PRODUCTS
YV2V Technical features - Mini-VRF outdoor unit
Model
YV2VYH010KAR
YV2VYH015KAR
YV2VYH015KAS
YV2VYH018KAS
m3/h
dB(A)
9.0
2.98
11.0
4.20
3 500
58
15.0
3.33
17.0
3.78
6 500
59
15.0
3.06
17.0
3.95
6 500
59
18.0
2.84
20.0
3.37
6 500
60
kW
kW
Type
3.02
2.62
Rotary
4.50
4.50
Rotary
4.90
4.30
Rotary
6.33
5.93
Rotary
mm
kg
830 x 960 x 380
74
1 250 x 960 x 380
120
1 250 x 960 x 380
120
1 250 x 960 x 380
120
5/8”
3/8”
3/4”
3/8”
3/4”
3/8”
3/4”
3/8”
2.6
3.6
4
4
50
30
4
100
30
8
100
30
8
100
30
9
kW
Cooling capacity
EER
Heating capacity
COP
Air flow
Sound Pressure Level at 1 m
kW
Electrical features
1/N/ 230V 50Hz
Power supply
Power input “cooling”
Power input “heating”
Compressor
3/N/ 400V 50Hz
Dimensions and Weight
Height x Width x Length
Weight
Piping connections
Gas
Liquid
Type
kg
Refrigerant charge
R410A
Piping length / Height difference
m
m
Max. piping length
Max. height difference
Max. number of indoor units
YV2V Technical features - Single module outdoor unit
Model
YV2VYH022KAS
YV2VYH028KAS
YV2VYH033KAS
YV2VYH040KAS
YV2VYH045KAS
22.6
4.28
25.0
4.24
11.100
57
28.0
3.80
31.5
3.95
11.100
57
33.5
3.35
37.5
3.75
14.100
60
40.0
3.51
45.0
3.88
14.100
60
45.0
3.36
50.0
3.70
14.100
60
kW
kW
Type
5.27
5.89
7.36
7.97
3/N/ 400V 50Hz
10.00
10.00
11.40
11.60
DC Inverter Scroll + Standard Scroll
13.40
13.50
mm
kg
1 808 x 990 x 750
240
1 808 x 990 x 751
240
1 808 x 1 390 x 750
360
1 808 x 1 390 x 751
360
1 808 x 1 390 x 752
368
3/4”
3/8”
7/8”
3/8”
1”
1/2”
1 1/8”
1/2”
10
10
1”
1/2”
R410A
10
10
10
16
175
50
19
23
26
kW
Cooling capacity
EER
Heating capacity
COP
Air flow
Sound Pressure Level at 1 m
kW
m3/h
dB(A)
Electrical features
Power supply
Power input “cooling”
Power input “heating”
Compressor
DC Inverter Scroll
Dimensions and Weight
Height x Width x Length
Weight
Piping connections
Gas
Liquid
Type
kg
Refrigerant charge
Piping length / Height difference
Max. piping length farthest indoor unit (m)
Max. height difference indoor/outdoor (m)
Max. number of indoor units
13
Combination of modular outdoor units
050
056
061
068
073
078
085
090
096
101
106
113
118
123
130
135
Capacity Cooling kW
Model
50.6
56.0
61.5
68.0
73.0
78.5
85.0
90.0
96.0
101.0
106.5
113.0
118.0
123.5
130.0
135.0
Heating kW
56.5
63.0
69.0
76.5
81.5
90.0
95.0
100.0
108.0
113.0
121.5
126.5
131.5
137.5
145.0
150.0
29
33
36
39
43
46
50
53
56
59
63
64
64
64
64
64
Maximum indoor units
Appearance
Manufacturer reserves the rights to change specifications without prior notice.
49
VRF Heat recovery system
YV2V 024 to 045
YV2V 3 Pipes Technical features - Single module outdoor unit
Model
YV2VYT024KAS-D-X
YV2VYT029KAS
YV2VYT035KAS
YV2VYT042KAS
YV2VYT045KAS
23.9
29.3
35.1
41.7
45.0
4.02
3.84
3.82
3.42
3.23
kW
26.5
32.8
39.2
46.8
50.7
4.3
4.1
4.2
4.1
3.8
Air flow
m3/h
11.100
11.100
14.100
14.100
14.100
Sound Pressure Level at 1 m
dB(A)
57
57
60
60
60
Power input “cooling”
kW
6.0
7.6
9.2
12.2
14.0
Power input “heating”
kW
6.2
8.0
9.2
11.4
13.4
Compressor
Type
Cooling capacity
kW
EER
Heating capacity
COP
Electrical features
3/N/ 400V 50Hz
Power supply
DC Inverter Scroll
DC Inverter Scroll + Standard Scroll
Dimensions and Weight
Height x Width x Length
mm
1 808 x 990 x 750
1 808 x 990 x 750
1 808 x 1 390 x 750
1 808 x 1 390 x 750
1 808 x 1 390 x 750
Weight
kg
240
240
368
368
368
3/4” / 3/4”
7/8” / 3/4”
1” / 7/8”
1” / 7/8”
1 1/8” / 1”
3/8”
3/8”
1/2”
1/2”
1/2”
10
10
23
26
Piping connections
Gas
Liquid
Refrigerant charge
Type
R410A
kg
10
10
10
Piping length / Height difference
Max. piping length farthest indoor unit (m)
175
Max. height difference indoor/outdoor (m)
50
Max. number of indoor units
13
16
19
Combination of modular outdoor units
HP
Capacity Coolin kW
Heating kW
Maximum indoor units
8
10
12
15
16
18
20
22
24
26
28
30
32
23.9
29.3
35.1
41.7
45.0
53.2
58.6
64.4
71.0
74.3
83.4
86.7
90.0
26.5
32.8
39.2
46.8
50.7
59.3
65.6
72.0
79.6
83.5
93.6
97.5
101.4 112.4 116.3 126.4 130.3 134.2 140.6 148.2 152.1
13
16
19
23
26
29
33
36
39
43
46
50
53
34
36
38
40
42
44
56
59
63
64
64
64
Appearance
Technical features - Heat recovery valve box
Model
VB1-112A
VB1-180A
VB1-280A
Capacity
3/N/ 400V 50Hz
Power supply
Total Capacity Index of Indoor Units
kW
Number of Connectable Indoor Units
≤ 11.2
> 11.2 & ≤ 18.0
> 18.0 & ≤ 28.0
Max. 5
Max. 8
Max. 8
3/8”
Piping connection
Liquid pipe - Connect to indoor unit
mm
3/8”
3/8”
Gas pipe -Connect to indoor unit
mm
5/8”
5/8”
7/8”
Liquid pipe-Connect to outdoor unit
mm
3/8”
3/8”
3/8”
Suction pipe-Connect to outdoor unit
mm
5/8”
5/8”
1”
High pressure gas pipe-Connect to outdoor unit
mm
1/2”
5/8”
3/4”
mm
180 x 400 x 300
180 x 400 x 300
180 x 400 x 300
12
12
13
Dimensions & Weight
Height x Width x Length
Weight
kg
50
46
48
100.3 103.6 112.7 116.0 119.3 125.1 131.7 135.0
64
64
YORK® AIR-CONDITIONING PRODUCTS
VRF Heat recovery system
Heat recovery valve box scheme
Outdoor unit side (3 pipes)
Indoor unit side (2 pipes)
Gas pipe
HP gas pipe
Liquid pipe
Suction pipe
Liquid pipe
Cooling and heating synchronously in one system
Heat recovery system can achieve cooling and heating synchronously in one system by valve box device.
2-Pipe system
Cooling and heating in two systems
Heat recovery system (3-Pipe)
Cooling and heating in one systems
Heat Recovery, More Energy-saving
The surplus heat of some indoor units’ condensation can be used for other indoor units for evaporation. Comparing with traditional
Air Conditioning system, save at least 15% energy.
Manufacturer reserves the rights to change specifications without prior notice.
51
VRF Technical features indoor units
High wall (EXV integrated)
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
YVHVXH022
2.2
2.5
YVHVXH028
2.8
3.2
37 / 33 / 31
37 / 34 / 31
YVHVXH036
3.6
4.0
YVHVXH045
4.5
5.0
YVHVXH056
5.6
6.3
600
YVHVXH071
7.1
8.0
800
41 / 36 / 33
41 / 36 / 33
230 / 1 / 50 + N + E
0.31
265 x 938 x 187
10.9
1/2”
1/4”
43 / 39 / 34
48 / 39 / 37
0.41
299 x 1 046 x 239
13
5/8”
3/8”
Cassette
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Current
HxWxD
Dimensions
and Weight
Weight
HxWxD
Panel
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
mm
kg
YVKVXH028 YVKVXH036 YVKVXH045 YVKVXH056 YVKVXH071 YVKVXH080 YVKVXH090 YVKVXH112 YVKVXH140
2.8
3.6
4.5
5.6
7.1
8.0
9.0
11.2
14.0
3.2
4.0
5.0
6.3
8.0
9.0
10.0
12.5
16.0
700
650
1 200
1 800
32 / 30 / 29
32 / 30 / 29
33 / 30 / 29
34 / 32 / 30
35 / 34 / 31
37 / 35 / 31
37 / 35 / 31
37 / 35 / 31
44 / 40 / 36
230 / 1 / 50 + N + E
0.47
0.67
0.76
260 x 570 x 570
240 x 840 x 840
295 x 840 x 840
17
30
38
60 x 700 x 700
80 x 950 x 950
2.8
6
3/8”
1/2”
5/8”
1/4”
1/4”
3/8”
Convertible console floor/ceiling
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
YVFVXH028
2.8
3.2
YVFVXH036
3.6
4.0
YVFVXH045
4.5
5.0
800
48 / 46 / 44
YVFVXH056
5.6
6.3
YVFVXH071
7.1
8.0
YVFVXH112
11.2
12.5
YVFVXH140
14.0
16.0
2 040
50 / 48 / 46
53 / 51 / 49
230 / 1 / 50 + N + E
0.3
655 x 990 x 199
38.3
1/2”
1/4”
3/8”
1/4”
1.8
700 x 1 580 x 240
54
5/8”
3/8”
Console
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
YV5VXH022
2.2
2.5
YV5VXH028
2.8
3.2
YV5VXH036
3.6
4.0
520
460
43 / 39 / 36
230 / 1 / 50 + N + E
0.44
640 x 720 x 255
18
1/2”
1/4”
52
YV5VXH056
5.0
6.0
580
48 / 46 / 42
YORK® AIR-CONDITIONING PRODUCTS
VRF Technical features indoor units
Low and Medium Static Pressure Duct
Model
Cooling
Heating
Air flow
Noise level at 1 m H / M / L
External static presure
Power supply
Electrical features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
Capacity
Low Static Pressure
Medium Static Pressure
YVDVXH022 YVDVXH028 YVDVXH036 YVDVXH045 YVDVXH056 YVDVXH071 YVEVXH056 YVEVXH071 YVEVXH080 YVEVXH090 YVEVXH112 YVEVXH114
kW
2.2
2.8
3.6
4.5
5.6
7.1
5.6
7.1
8.0
9.0
11.2
14.0
kW
2.5
3.2
4.0
5.0
6.3
8.0
7.1
8.0
9.0
10.0
12.5
16.0
m3/h
400
500
850
1 250
1 200
1 900
2 100
dB(A)
35 / 32 / 30
39 / 37 / 35
43 / 37 / 35
44 / 40 / 36
Pa
0 ~ 20
50 ~ 96
80 ~ 120
V/Ph/Hz
230 / 1 / 50 + N + E
A
0.27
0.38
0.55
1.1
2.2
mm
220 / 610 / 500
220 / 1 105 / 500
300 / 1 180 / 743
270 / 1 135 / 742
kg
15
16
25
28
39
50
3/8”
1/2”
5/8”
1/2”
5/8”
1/4”
1/4”
3/8”
1/4”
3/8”
High Static Pressure Duct
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / L
External static presure
Power supply
Electrical features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
Pa
V/Ph/Hz
A
mm
kg
YVGVXH056
5.6
6.3
YVGVXH071
7.1
8.0
1 500
42 / 40
YVGVXH080
8.0
9.0
YVGVXH090
9.0
10.0
1 560
YVGVXH112
11.2
12.5
1 600
45 / 40
YVGVXH140
14.0
16.0
2 100
100
230 / 1 / 50 + N + E
2.55
360 x 1 350 x 875
62
5/8”
3/8”
2.05
360 x 970 x 875
48
1/2”
1/4”
YVGVXH226
YVGVXH280
22.6
28.0
25.0
31.6
4 050
54 / 49
5.05
360 x 1 610 x 840
92
1”
3/8”
Fresh Air Unit
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m High speed
External static presure
Electrical features Power supply
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
Pa
V/Ph/Hz
mm
kg
YV4VXH140
14.0
8.9
1 600
48
YV4VXH226
22.6
15.2
2 300
YV4VXH280
28.0
17.8
2 800
55
100
230 / 1 / 50 + N + E
360 x 1 350 x 875
62
5/8”
3/8”
360 x 1 750 x 840
120
1”
3/8”
Heat Recovery Ventilator
Model
Air flow
External static presure
Power supply
HxWxD
Dimensions
and Weight
Weight
m3/h
Pa
V/Ph/Hz
mm
kg
YV6VXH015
150
50
YV6VXH026
200
60
276x940x685
276x940x686
YV6VXH080
800
80
YV6VXH100
1 000
100
230 / 1 / 50 + N + E
28.7
387x1227x1115
387x1227x1116
85.5
Manufacturer reserves the rights to change specifications without prior notice.
53
Controllers & BMS
YR-H71 Wireless Controller
Elegant and slim design, LCD display, 4 Operation modes (Cool/Dry/Heat/Fan),
Timer ON/OFF setting up to 24 Hr., Temperature control range, Fan speed selection.
Standard for High Wall and Console, optional for Duct, Cassette and Floor Ceiling.
YR-E17 Wired Controller
Exclusive design, Big LCD display, 4 Operation modes (Cool/Dry/Heat/Fan),
Temperature setting, Timer setting,Fan speed selection, Group controller up to 16 indoor units.
Standard for Duct, Cassette and Floor Ceiling. Optional for High Wall and NO optional for Console.
YCZ-A003 Touch Screen Central Controller
Max. 128 indoor units control.
Single or all query and control, such as ON/OFF/Mode setting/Temp setting/ Fan setting ect.
Mode lock function, Blue light background, LCD display screen.
IGU05 Touch Screen Central Controller Translator
Translating protocol between home bus and RS485.
Connecting with one outdoor (combination model also regard as one) system.
Work with Touch Screen Central Controller
HCM-01 Central Controller With Monitor Software
Max. 128 indoor units control.
Single or all query and control, such as ON/OFF/Mode setting/Temp setting/ Fan setting ect.
Mode lock function, Blue light background, Software Monitoring on any PC.
IGU02 BacNet/IP Translator
IGU06 LonWorks Translator
Translating protocol between home bus
and RS485.
Connecting with one outdoor (combination
model also regard as one) system.
Work with Central Controller with Monitor
Software and BacNet/IP Converter.
Translating protocol between home bus
and RS485.
Connecting with one outdoor (combination
model also regard as one) system.
Work with LonWorks Converter.
HCM-04 BacNet/IP Converter
IGU07 LonWorks Converter
Max. 60 indoor units control.
Connect A/C system to BMS by
BacNet/IP protocol.
Max. 32 indoor units control.
Connect A/C system to BMS by
LONWORKS protocol.
54
YORK® AIR-CONDITIONING PRODUCTS
VRF System - System Diagram
Possible to connect to JCI Metasys
Piping accessories
Model
FQG-B335A
FQG-B506A
FQG-B730A
FQG-B1350A
HZG-20A
HZG-30A
HZG-20B
HZG-30B
FQG-R335A
FQG-R506A
FQG-R730A
FQG-R1350A
HZG-R20A
HZG-R30A
System
Name
Function
Application
2 pipes
2 pipes
2 pipes
2 pipes
2 pipes
2 pipes
2 pipes HE
2 pipes HE
3 pipes
3 pipes
3 pipes
3 pipes
3 pipes
3 pipes
Indoor mainfold pipe
Indoor mainfold pipe
Indoor mainfold pipe
Indoor mainfold pipe
Outdoor branch pipe
Outdoor branch pipe
Outdoor HE branch pipe
Outdoor HE branch pipe
Indoor mainfold pipe
Indoor mainfold pipe
Indoor mainfold pipe
Indoor mainfold pipe
Outdoor branch pipe
Outdoor branch pipe
Refrigerant distribution
Refrigerant distribution
Refrigerant distribution
Refrigerant distribution
Refrigerant gathering
Refrigerant gathering
Refrigerant gathering
Refrigerant gathering
Refrigerant distribution
Refrigerant distribution
Refrigerant distribution
Refrigerant distribution
Refrigerant gathering
Refrigerant gathering
Total indoor units capacity < 33.5 kW
33.5 kW ≤ Total indoor units capacity < 50.6 kW
50.6 kW ≤ Total indoor units capacity < 72 kW
73 kW ≤ Total indoor units capacity
2 module combinations
3 module combinations
2 module HE combinations
3 module HE combinations
Total indoor units capacity < 33.5 kW
33.5 kW ≤ Total indoor units capacity < 50.6 kW
50.6 kW ≤ Total indoor units capacity < 72 kW
73 kW ≤ Total indoor units capacity
2 module combinations
3 module combinations
YORK VRF System
A
The YORK VRF system with DC Inverter Scroll is working like the
VRF principle and offers you economical air-conditioning system for
projects, which are requiring more capacity than the normal split and
multi split solutions.
B
C
The lengths for the connecting tubes between the indoor and outdoor
have been prolonged, which brings you more flexible solutions for
complex air-conditioning projects.
A – Maximum single way pipe length: 175m
B – Maximum difference in height: 50m
(110m for HE outdoor units)
C – Maximum difference in height between 2 indoor units: 15m
(30m for HE outdoor units)
55
About Johnson Controls
Johnson Controls delivers products, services and solutions that increase energy efficiency and lower operating
costs in buildings for more than one million customers.
Operating from 500 branch offices in more than 150 countries, the company is a leading provider of equipment,
controls and services for heating, ventilating, air-conditioning, refrigeration and security systems. Johnson Controls
is involved in more than 500 renewable energy projects including solar, wind and geothermal technologies.
Its solutions have reduced carbon dioxide emissions by 13.6 million metric tons and generated savings of $7.5
billion since 2000. Many of the world’s largest companies rely on Johnson Controls to manage 1.5 billion square
feet of their commercial real estate.
PUBL-7393 - 02.2017
© 2017 Johnson Controls, Inc. · www.johnsoncontrols.co.uk
Johnson Controls reserves the right, in line with continuing research and development, to amend or change specifications without notice.
YORK® is a registered trademark of Johnson Controls, Inc. in the United States and other countries.
4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement