Hylite Mightylite MFL016, MLF028 LED Floodlight Installation & operating instructions
Below you will find brief information for LED Floodlight Mightylite MFL016, LED Floodlight Mightylite MLF028. The Hylite Mightylite floodlight is a low energy, high powered outdoor LED floodlight which is suitable for installation on solid walls in a range of locations including entrances, gardens, staircases, garages and outdoor parking areas. The unit requires connection to a 230 AC 50Hz mains electricity supply.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
FIXING THE CONNECTION BOX (Cont)
• Use the connection box Fixing Holes [Fig.6] to mark the 4 drill holes required to
secure the box to the wall (and mark the cable outlet location if required). Drill
the wall and screw the connection box onto the wall using the screws and wall
plugs provided.
• Once the wire(s) has been fed through the Sealing Gland, the nut on the gland
should be gently tightened up against the gland body [Fig. 8] to ensure the
wire(s) is secured in place and no water can get though into the connection box.
WIRING THE FLOODLIGHT
• Once the power cable has been fed through the cable gland (or sealing
grommet if using the knock-out at the rear of the connection box)
approximately 6mm of insulation should be stripped from each of the cores of
AC cable ready to attach it to the terminal block in the front of the light fitting.
NOTE: The Hylite Mightylites MLF016 and MLF028 are Class 1 fittings and therefore need to be Earthed
CONNECTING TO POWER SUPPLY
• Connect the BROWN or RED (Live) wire to the terminal (marked “L”) holding the
single BROWN wire in the floodlight unit [Fig.8].
• Connect the BLUE or BLACK (Neutral) wire to the terminal (marked “N”) holding
the BLUE wire in the floodlight unit.
• Connect the YELLOW/GREEN or BARE (Earth) wire to the terminal (marked
“EARTH”) holding the YELLOW/GREEN wire in the floodlight unit
• After the connections have been secured, the floodlight front (Connection Box
front) should be fastened to the Connection Box using the 4 Connection Box
Screws provided [Fig.9]
• Once screws are secure, the screw covers (provided) should be fitted should be
fitted [Fig.9]
• To adjust the MightyLite simply hold the Connection Box firmly whilst moving
the head of the floodlight to the required position.
F4 Enterprises Limited
7 Abbey Square, Chester
CH1 2HU, UK
Fixing Holes
Tel: +44 (0)1352 736120 www.f4enterprises.co.uk
Fig.6
Fig.7
Fig.8
Fig.9
Mightylite 16W / 28W LED Floodlights
Model: MFL016 / MLF028
Installation & operating instructions
HYLITE MIGHTYLITE – INSTALLATION AND OPERATING INSTRUCTIONS
The Hylite Mightylite floodlight a low energy, high powered outdoor LED floodlight which is suitable for installation on solid walls in a range of locations including entrances, gardens, staircases, garages and outdoor parking areas
The unit requires connection to a 230 AC 50Hz mains electricity supply.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN, AND CHECKED TO ENSURE IT IS SAFE BEFORE USING
PLEASE FOLLOW THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS LIGHT
The risk of electric shock should be minimized by the installation of appropriate safety devices including the
incorporation of an RCCB (Residual Current Circuit Breaker) into the main distribution board.
DO NOT wire this floodlight directly into the lighting circuit. Use a switched fused spur. Cables should always be
protected against short circuit and overload by use of an RCD.
Ensure the voltage marked on the product is the same as the electrical power supply to be used.
DO NOT install the light where it is likely to be knocked or hit; in hot or humid conditions such as bathrooms, shower
rooms or saunas; or near an exhaust outlet e.g. boiler flue, dryer outlet.
IMPORTANT OPERATION & MAINTENANCE INSTRUCTIONS
DO NOT position the light near flammable or combustible materials (such as wood, cloth, paper) or near flammable, combustible or explosive liquids, solids, gases or equipment.
DO NOT direct the light into a person’s eyes. This light has a very intensive light output, which if incorrectly used could cause eye damage.
ALWAYS disconnect the mains power supply before servicing or performing any maintenance.
ALWAYS maintain the light in good condition, with repairs only undertaken by a qualified electrician
ONLY carry out repairs using genuine parts. Non-authorized parts may be dangerous and will invalidate the warranty
PARTS INCLUDED
1 x Mightylite LED Floodlight
1 x Connection box
1 x Cable gland
4 x Connection box screws
4 x Connection box screw covers
4 x Connection box fixing screws
4 x Connection box fixing screw covers
TOOLS REQUIRED
Electric/hand-held drill
No.8 masonry drill bit
Electricians screwdriver
Large cross-head screwdriver
Small cross-head screwdriver
Wire cutters
THIS PRODUCT IS SUITABLE FOR WALL MOUNTING ONLY
WIRING REQUIREMENTS
The unit requires connection to a 230 AC 50Hz mains electricity supply.
It is recommended that the unit is connected to the domestic lighting circuit via a
5 amp fused spur and using 2-core round flexible cable of at least 1mm 2 gauge
(waterproof cable should be used for outdoor installations).
Live Neutral Earth
It is also advisable to install a single pole wall switch to allow easy control of the floodlight (Fig. 1).
N
INSTALLATION INSTRUCTIONS
E
CHOOSING A MOUNTING LOCATION
• Mount the floodlight onto solid brick or woodwork, 3 - 5m above the ground
[Fig. 2]
C L1
FIXING THE CONNECTION BOX
WARNING: Isolate the power supply before installation.
• Position the unit on the wall and mark the position for the connection box
(which can be positioned in either landscape or portrait planes [Fig. 3]).
• Ensure the wires can easily enter the connection box through either one of the
knock-outs on the side of the connection box, or through the knock-out at the
rear of the box.
3
NOTE: It is recommended that the knock-outs on the sides of the
connection box are used in conjunction with the cable gland [Fig 4.] as
using the knock-out at the rear of the connection box will reduce the
weatherproof rating of the unit to IP23.
1 5
• However, If feeding a wire(s) through the knock-out at the rear of the connection
box, this will need to be removed, the sealing grommet fitted [Fig.5] and the
wire pushed through into the connection box BEFORE it is secured to the wall.
• If feeding a wire(s) through the side knock-outs, it is easiest to fit the cable
gland to the connection box [Fig.4] BEFORE securing it to the wall, and wires
should enter the connection box from the sides or underneath, NOT from the top.
TO MAINS
N in N out
L in
Earth
L out
Fig.1
MIGHTYLITE
Fig.2
3-5m
Fig.3
Portrait
Landscape
Fig.4
Less sensitive
PIR sensor
To Mains
N In
L In
N Out
L Out
MightyLite
FROM MAINS
SUPPLY
3 AMP FUSE