Asheridge ASH-EOC-01 Ethernet Over Coax Adapter User Guide
Annonce
Annonce
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 1
ASH - EOC-01
Ethernet
Over Coax
Adapter
User Guide
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 2
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 3
ASH - EOC-01
User’s Guide
1
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 4
Table of Contents
Warning and Safety Information
Product Overview
Package Contents and Accessories
Introduction
Indicators and Ports
LED Indicator Definitions
Connection Interfaces
Basic Connection
Before Installation
Hardware Requirements
Installation Steps
Connect to your Home Entertainment Network
Home Network Environment
Specifications
Service and Support
13
13
14
18
10
10
11
12
18
20
21
8
9
3
8
2
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 5
Warning and Safety Information
Please read this user’s manual before operating this product. The information contained in this document is subject to change without notice. Product features and specifications may be different depending on the model purchased
Safe Use of This Product
Carefully follow the warnings and safety notices presented within this manual.
Please pay special attention to the following indications of potentially hazardous situations:
Warning:
Indicates a hazardous situation, which, if not avoided, could result in serious injury.
Caution:
Indicates a situation, which, if not avoided, could result in damage to this product or other devices.
Note:
Indicates additional user information to make the user aware of possible problems and to help the user understand, use and maintain the product.
3
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 6
4
Accessories
Use only those accessories and attachments provided with your product. Use of accessories or attachments that are not supplied or approved by the manufacturer may be unsafe and detrimental to the life or performance of the product and will immediately invalidate any product warranty.
Operational Environment
Avoid high moisture conditions and keep away from all liquids or humidity. This product must not be exposed to dripping, splashing or high humidity. Do not use this product in any location where it may come into contact with any liquid or vapor.
Product Care and Servicing
Attempts to dismantle the product may be unsafe and may be detrimental to the life or performance of the product and will immediately invalidate any product warranty. Servicing must be done by qualified service personnel only.
Proper Cleaning
Proper cleaning will prevent damage to the unit and its components. The product, its accessories and attachments should only require occasional wipe with a dry cloth. Remove plug from the wall outlet before cleaning the product. Do not spray any substance or use any polishes, thinners, abrasive cleaning products, liquids or aerosol products to clean the product, its accessories or attachments.
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 7
Installation and Set-Up
A suitable operating environment is required to safely utilise this product and to avoid malfunctions or damage to the unit. Do not place the product where it may be subject to physical shock or vibration or where the product may drop, topple, slide or shake, which may cause personal injury or damage to the product not covered by the manufacturer’s warranty. Openings on the housing of the product are required for ventilation. Do not block or obstruct the airflow through these openings. Do not operate the product on a soft surface such as carpet, rug, bed, etc. as these surfaces will obstruct airflow, may cause the product to overheat and will invalidate the warranty. Do not install the product into any bookcase, shelf or rack without ensuring that a minimum of 100mm of clear space is available at the front, rear, sides and top of the product. Do not install the product where it may be exposed to direct sunlight or radiant, convected or conducted heat from an open fire or radiator. The product should not be placed on any surface that may become warm during use (such as on top of a VCR or A/V amplifier) and nothing should be placed on top of the product. Do not cover the product. Objects containing liquids, such as vases, flowerpots, etc. must not be placed on top of the product.
Power Source
The product must ONLY be used with the power adapter supplied by the manufacturer. If it is necessary to operate the product in another country or geographical area with a different power source, an approved adapter for that country or location must be obtained from your retailer. The product and power supply will get warm to the touch during normal use.
5
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 8
6
Warning:
Because the power adapter is designed only for the use with your product, connecting it to other devices may damage the adapter or other devices.
Federal Communication Commission (FCC)
Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
●
●
●
●
Re-orientate or relocate the receiving antenna.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Install an approved low pass filter.
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 9
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
7
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 10
Product Overview
Package Contents and Accessories
Thank you for purchasing the ASH-EOC-01. Before you start installing the device, please verify that your package contains the below items:
√
√
√
ASH-EOC-01
Power Adapter
User’s Guide
8
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 11
Introduction
The ASH EOC-01 provides a simple solution to link your network-connectable devices from room to room using your existing coaxial cable. It acts as a bridge between the standard Ethernet network and your home coaxial wiring system for transferring network data and streaming multimedia content. Its connection and mechanism is compliant with the MoCA® 1.1 standard using clean and shielded coaxial cables as the transferring medium. While coexisting with CATV and terrestrial TV services, the ASH EOC-01 is capable of providing high-speed internet access for entertainment devices such as game consoles, media players, internet enabled TVs, DVRs (digital video recorders) etc.
9
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 12
Indicators and Ports
LED Indicator Definitions
The LED lights located on the front panel indicate the status of the Ethernet network, coaxial network and power connection.
LED
Power
Blue:Power On
Ethernet
Green: 100mbps
Orange: Gigabit Ethernet
Ethernet Over Coax
Yellow: MoCA® ethernet over coax link
10
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 13
Connection Interfaces
TV In
Coax cable connection from wall outlet.
TV Out
Coax cable connection to local
TV, STB or other local coax device.
Ethernet
Connection to
Ethernet Router or
Ethernet device.
Power
Power from mains wall outlet via adapter supplied.
11
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 14
Basic Connection
Internet
Router
Ethernet
Cable
ASH-EOC-01
Coax Cable
Internet
Enabled T.V.
Ethernet
Cable
ASH-EOC-01
12
This chapter demonstrates the basic setup, which requires two ASH EOC-01 units used as a pair to connect an internet enabled TV to an existing network.
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 15
As illustrated on page 12, the router uses an Ethernet cable to connect to the
ASH EOC-01 and then uses the coaxial cable between the adapters to transfer data. After connecting the Internet enabled TV to the ASH EOC-01, the Internet enabled TV is linked to the network and will be able to access Internet services through the router.
Before Installation
Before installing the ASH EOC-01, you must confirm that the rooms you choose are part of your home coaxial network.
Hardware Requirements
●
●
●
Ethernet Cable
Coaxial Cable
ASH EOC-01 (at least two devices)
13
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 16
Installation Steps
1.
Connect the existing coaxial cable from your TV or set-top box (or other device that was previously connected to the coaxial cable wall outlet) to the TV OUT port on the rear panel of each of the EOC-01 located in different rooms.
ASH-EOC-01
Set Top Box
TV Out
Coax Cable
Note:
The TV OUT port filters out the Internet-to-tv signal so should not be connected to other Internet-to-tv devices including Internet-to-tv DVR’s or STB’s. Where this is required external splitter should be used.
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 17
2.
Connect the coaxial cable from the wall cable outlet to the CABLE IN port on the rear panel of the two ASH EOC-01 devices located in the two rooms.
ASH-EOC-01
Coax Wall Outlet
TV In
Coax Cable
3.
Now you can turn on your TV to confirm that the TV service is available.
If your TV service is not available, verify the cables are securely connected to the correct ports as stated in the previous steps. (Please disregard if you are not using the product along with a television signal).
15
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 18
4.
Connect the power adapter from the wall outlet to the POWER port on the rear of the two EOC-01 devices. The Power Blue LED light will turn on.
ASH-EOC-01 Power Source
16
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 19
6.
After the coaxial network is established, connect the Ethernet cable from the network device of one room to the Ethernet port of this product first.
In this example, we connect the router with the EOC-01.
ASH-EOC-01
Ethernet
Cable
7.
Connect another Ethernet capable product to the Ethernet port of the EOC-01 in the other room.
For example, we connect an Internet enabled TV to the EOC-01 as shown in the illustration. Now, the TV is able to communicate with the router and access the Internet.
Router
Internet
Enabled TV
Ethernet
Cable
ASH-EOC-01
17
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 20
Connect to Your Home Entertainment Network
Home Network Environment
The coaxial network that has been widely deployed in almost every building is a good and convenient backbone for your home networking environment. By performing the basic installation that is introduced in previous chapter, you can easily add each of your rooms to your home network. See reference applications below for linking your network devices.
18
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 21
Ethernet
Switch
Cable TV
Service
Splitter
Smart
T.V.
Games
Console
ASH-EOC-01
Router
Ethernet
Cable
ASH-EOC-01
Coax
Smart
T.V.
Ethernet
Cable
ASH-EOC-01
19
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 22
20
Specifications for ASH-EOC-01
Ethernet Interface
Cable Interface
Diplexer
MoCA® System
Gigabit-Ethernet Port
Cable Input
Loop Through Output
Low Pass
Insertion Loss
Return Loss
High Pass
Insertion Loss
Return Loss
Main Chip
Network Centre
Frequency Range
Channel Bandwidth
Throughput
RJ45
F-Type, 75 Ohm
F-Type, 75 Ohm
5-1002MHz
2dB Max
10dB Min
1125 -1525MHz
3dB Max
10dB Min
Entropic, EN2510
MoCA® 1.1 Compliant
1150 - 1500MHz
MoCA® D Band supported
50MHz
Min. 130Mbps MAC rate while PHY rate 250 Mbps
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 23
Specifications for ASH-EOC-01 (Cont.)
Power Adapter
Plastic Housing
Regulation
Certification
Main Input
DC Output
Power Consumption
Dimensions
CE Compliant
RoHS Complaint
100 - 240 VAC ~, 50/60Hz
12V@1A
<10W
125 x 80 x 28 mm
EMC / LVD
WEEE
Service and Support
For service and support, either contact your authorised retailer or service provider, stating the serial number of your product, date and place of purchase and the nature of the fault.
21
Asheridge ASH-ECO-01 User Guide FINAL:Layout 1 15/5/12 11:52 Page 24
Download
Annonce