Monarch Water Scaleout Water Softener Installer & User Guide
The Monarch Water Scaleout is a water softener that removes calcium and magnesium from your water supply, preventing the formation of scale buildup. This can improve the performance of your appliances, such as your washing machine, dishwasher, and kettle, and can also help to extend their lifespan. The Scaleout is easy to install and maintain, and comes with a 3-year parts and 12-month labor warranty.
Advertisement
Advertisement
Model No.
MONARCH WATER
Installer & User Guide
Effective February 2013
For Monarch Scaleout
‘Suppliers to H.M. the Queens Estate at Sandringham’
Monarch Water Ltd. Halesworth Road Bramfield IP19 9HP
T 01986 784759 F 01986 784769
[email protected] www.monarchwater.co.uk
MONARCH SCALEOUT INSTALLATION INSTRUCTIONS
Thank you for choosing our SCALEOUT. Please read the following carefully, which if followed correctly, should ensure the installation is trouble free.
Before you install the unit, please ensure you have the correct model with regard to demand placed upon unit and also the water hardness. Ensure + models are used on all water hardness over 480ppm. Monarch has a nationwide database on all water hardness’s for your assistance
A. PLANNING THE INSTALLATION
• Always observe the water byelaws.
• Ensure there is only one rising main.
• Make sure you have allowed space for access to the unit for any possible
maintenance in the future.
• Check the water pressure and locate the rising main. Be aware of
condensation occurring in warm environments. If condensation occurs, we
recommend the unit is sited in a small tray that allows the water to evaporate.
B. SITING THE SCALEOUT – Fig 1
• Where possible, this should be close to the rising main.
• ‘T’ off for an untreated mains supply for the outside tap.
• Ensure that the unit is not subject to below 4 or above 50C.
• If siting the unit within a kitchen cupboard, loft etc. Ensure that the base/
floor is adequately supported.
• If the unit is being installed in your loft, 1st, 2nd floor etc., it is recommended
to house the unit within a plastic tank and insulate well.
• The overflow on the plastic tank should be a minimum of ¾”in size. Failure to
install the unit in a suitable tank will void the Guarantee.
C. NON-RETURN VALVE
In domestic applications i.e. house, bungalow, apartment, flat etc, a single check valve should be fitted. All other applications require a double check valve.
D. DRINKING WATER FACILITY
The unit produces drinking water, so unlike a salt based softener, no dedicated tap is required.
E. MATERIAL CHECK LIST
• The unit includes an installation kit as relevant to the model ordered.
• For 28mm supplies a full upgrade for the unit is available - details on request.
2
F. WATER PRESSURE TEST
• It is IMPORTANT that a pressure check is carried out.
• Low and high pressure can result in either damage to, or failure of the unit.
• If daytime static water pressure* exceeds 3.5 bar (50psi) a 5 bar pressure limiter
should be fitted. *50psi daytime pressure can reach nearly 100psi at night!
• Minimum dynamic pressure must exceed 1.5 bar.
• If in any doubt please call us on 01986 784 759
OPTION 1 WITH POST FILTER CONNECTED REMOTE TO SCALEOUT
G. INSTALL BYPASS VALVES & NON-RETURN VALVE
Form an installation as per Fig 1 Below.
Scaleout water to service
SPF10
Bypass Valve
(shut)
Outlet Valve
(open)
Non-Return
Valve
Supply to outside tap
Inlet Valve
(open)
Pressure Limiting Valve
(if required)
STOP TAP ON
INCOMING MAIN
FIG 1
Checklist
✔
Water pressure 1.5 – 5 bar (20 – 70psi)
✔
Access for maintenance
FIG 1
3
S15T
H. POST FILTER – See Fig 2
Using the short chrome braided hose provided; connect this to the OUTLET valve/male iron adaptor on the pipework and the OUTLET connection of the
Post Filter. Fix SPF10 Post Filter to wall using bracket provided.
If this short hose is not appropriate, an additional longer braided hose is included within the installation kit.
FIG 2
OUTLET VALVE
(OPEN)
BYPASS VALVE
(CLOSED)
SPF10
HOSE FROM
OUTLET OF
SCALEOUT
I. INLET & OUTLET CONNECTIONS – See Fig 3
Under no circumstances use washing machine hoses or plumb the unit in solid copper pipe.
Connect the inlet hose from the INLET valve/male iron adapter on the pipe work to the INLET of the Scaleout - see directional arrow on top of unit.
Connect the outlet hose from the Scaleout to the INLET of the Post Filter.
When all hoses are connected, final layout should resemble FIG 1.
PLAN VIEW OF SCALEOUT CONNECTION HEAD
FIG 3
INLET HOSE
FROM INLET
VALVE
OUTLET HOSE TO
INLET OF
POST FILTER
4
OPTION 2 WITH POST FILTER CONNECTED DIRECTLY TO SCALEOUT
J. INSTALL BYPASS VALVES & NON-RETURN VALVE
Form an installation as per Fig 4 Below.
Scaleout water to service
Bypass Valve
(shut)
Outlet Valve
(open)
Non-Return
Valve
Supply to outside tap
Inlet Valve
(open)
Pressure Limiting Valve
(if required)
STOP TAP ON
INCOMING MAIN
This connection is not tightened
Checklist
✔
Water pressure 1.5 – 5 bar (20 – 70psi)
✔
Access for maintenance
FIG 4
K. INLET & OUTLET CONNECTIONS – See Fig 4
Under no circumstances use washing machine hoses or plumb the unit in solid copper pipe.
Connect the inlet hose from the INLET valve/male iron adapter on the pipe work to the INLET of the Scaleout - see directional arrow on top of unit.
Connect the outlet hose from the OUTLET valve/male iron adaptor on the pipe work to the OUTLET of the Post Filter.
PLEASE NOTE
1 Spare fittings and hoses are included with your unit that may not be needed
2 The Scaleout comes with the Post Filter attached. However the seal from the black adaptor on the inlet of the Post Filter has not been tightened (see fig 4).
This is to allow for easy disconnection if the Post Filter is fixed remotely and to ensure the fibre washer is not damaged. Therefore please ensure this connection is tightened prior to installation.
5
I. TEST INSTALLATION FOR LEAKS
Close Inlet and Outlet valves to the unit and open Bypass valve.
Open mains stopcock and flush the new pipe work for a minimum of 5 minutes.
This can be done using any mains water tap inside the property i.e. utility room, kitchen cold tap or wash hand basin in a bathroom.
Close Bypass valve, then open Inlet and Outlet valves slowly.
Allow water to run slowly until all air is purged from the unit, then close tap.
Allow unit to rest for 15 minutes before future use. Check for leaks.
GOING ON HOLIDAY?
• Fig 5 shows the valves in the Service position (Bypass is closed and Inlet &
Outlet are open).
• We highly recommend you bypass your unit when going away on holiday.
• Simply turn Inlet, Outlet and Bypass valves ¼ turn to put valves into
Bypass positions.
• Upon your return, move valves back to the Service position (as Fig 5 below).
FIG 5
Scaleout water to service
SPF10
Bypass Valve
(shut)
Outlet Valve
(open)
Non-Return
Valve
Supply to outside tap
Inlet Valve
(open)
Pressure Limiting Valve
(if required)
STOP TAP ON
INCOMING MAIN
6
S15T
Hints and Tips about your new Scaleout
1
Bath and shower surfaces will become smoother – be careful, in particular the
young and infirm – why not buy a bath mat?
2
Cut washing powder down by approx. 40%. If possible look to use a pure soap
powder as this will help give optimum results.
3
Scaleout water will become available throughout your system in varying
time spans. Conventional systems (tanks in your roof) will take anything
from 4-10 days, whilst mains fed Pressurised Systems will give treated water
within 2-3 days.
4
Dishwashers – On most installations the dishwasher is to be connected to
the Scaleout water. We recommend that you continue to add a small amount of
salt to the appliance as before, as this helps the salt holder in the appliance
stay clean. We do not however recommend that crystal glass; solid silver or
silver plated items are washed in your dishwasher as etching may occur. Less
dishwasher liquid may be required and in certain cases this will also apply to
rinse aid. For best results use a natural soap detergent/cleaning agent.
On dishwashers connected to untreated water, you should continue to put salt
into the dishwashers own softener.
It will help if your dishwasher could be de-scaled prior to the installation of the
Scaleout. This would also apply to your shower cubicle too. For best results use
a phosphate free dishwashing detergent.
5
Outside Tap – It is recommended to leave your outside tap on mains water.
Additionally, in the wintertime we recommend that this tap is isolated via an
internal valve to prevent freezing.
6
Existing scale – Scaleout water will immediately begin to de-scale your pipes
and appliances. Your hot water cylinder will take longer to de-scale than your
pipe work; in some cases 12-18 months; therefore you may notice different
levels of Scaleout water for some time whilst the system is de-scaling. This is
particularly noticeable in your bath and shower.
7
Scaleout water will have no adverse effect in your heating system. In every case
a corrosion inhibitor such as Sentinel X100 must be used.
8
Helping your kettle last longer: Your kettle will continue to have an amount of
scale, but the level can be kept to a minimum by running the tap for 5-10
seconds prior to filling. Additionally, it is recommended to empty the kettle of
any water left over from the previous use. When emptying, you may notice
scale flakes and possibly ‘milky’ water too. This is normal and proof that the
Scaleout is working at optimum performance. Flakes are caused by taking the
water to boiling point and will not happen elsewhere throughout your system.
9
The Scaleout exchanges Calcium ions into Calcium crystals. Crystals are
collected by the Post Filters internal cartridge, which is to be changed
annually (or before in extremely hard water areas). You may sometimes
notice a white dust form after any water has evaporated. This is non-scale
forming magnesium (a flavour carrier) being retained. Any dust can simply be
removed by wiping with a damp cloth on an as-and-when basis.
10
Toilets, Showers, Taps etc: Because there is no direct flow across these
surfaces, other than water splashing, the old scale may need to be removed
with a scale remover. Any new accumulation will wipe off easily.
4
Installation Conditions Effective February 2013
The Monarch Scaleout is fully covered by a retrospective 3 year parts and 12 months labour guarantee for installation within the hard water regions of mainland England as detailed on Monarchs National Service Coverage Area, from date of original purchase. Installations outside this area are automatically covered by a 3 year parts only ‘exchange’ warranty.
Definition and example of ‘Retrospective: If the resin fails at 30 months, then new resin will be replaced under the 3 year guarantee but charged at 30/36ths of the replacement resin cost, plus delivery, plus VAT.
PLEASE NOTE
This guarantee has the following conditions, and is not covered by the following.
1. Damage caused by high water pressure, we strongly recommend a 5 bar water pressure
limiting valve on the inlet to your water supply, where daytime water pressure exceeds a
static pressure of 3.5 bar (50psi).
2. This Scaleout is suitable for a mains water supply only.
3. Damage caused by a dirty mains water supply. The installation of a Monarch Debris
Filter - cost £73.00 inc VAT & postage - on the supply to your unit cancels this clause.
The majority of debris in water is caused by local authority work on the water main.
If notified in advance, by your local water authority, please put your unit onto ‘bypass’,
see Fig 5.
For Bypass: Close both Inlet & Outlet valves, and open Bypass valve.
For Normal Service: Open both Inlet & Outlet valves, and close the Bypass valve.
4. Call outs due to incorrect installation. If you have any queries when
installing your Scaleout, please call us on 01986 784759.
5. The use of any other hoses than those provided. Under no circumstances use washing
machine hoses.
6. The effect of aggressive water, the degradation and/or blinding of resin and/or chlorine
attack on resin.
7. Under no circumstances plumb in the unit in solid copper.
8. The installation kit is only covered by the OEM twelve-month parts
‘exchange’ warranty only.
9. Compensation as a result of cancelled appointments, damage caused by, or incorrect
installation of the unit. In the unlikely event of a fault, put the unit onto Bypass, see 3
above ref ‘For Bypass’ until an engineer calls.
THE ABOVE DOES NOT AFFECT YOUR STATUTORY RIGHTS
Incoming Water Conditions
Min – Max Operating pressure
Temperature pH
Max Iron content
Max Manganese content
Max Copper content
Oil & Phosphates
H2S
1.5 – 5 bar
4 – 50C
6.5 – 8.5
0.3 mg/l
0/05 mg/l
1.3 mg/l
Free
Free
8
Monarch National Service Coverage Areas - Effective February 2012.
The below Postcodes (see map below) are automatically covered by a 3 year parts and
12 month labour warranty.
B
BA
BH
BN
BS
CB
CM
CO
GL
HP
IP
LE
CT
CV
DT
GU
LONDON inset
LU
LN
ME
MK
NG
NN
NR
OX
PE
PO
RG
RH
SG
SL
SN
SO
SP
SS
TN
IMPORTANT
Scaleouts sold outside the above Postcodes are to be covered strictly by a parts only ‘exchange’ warranty.
All parts sent back to
Monarch are at the expense of the sending parties.
All repaired or replaced items will be returned to the sender on a no charge basis whilst covered by the parts exchange guarantee.
Once the parts exchange guarantee has expired, Monarch reserves the right to make a charge for any postage/delivery, labour and parts charges that is deemed necessary.
Monarch will endeavour to keep these charges at the lowest cost whenever possible.
9
SCALEOUT INSTALLATION RECORD
Original Installation Date
1st Resin Change Date
2nd Resin Change Date
3rd Resin Change Date
4th Resin Change Date
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
SPF10 INSTALLATION RECORD
Original Installation Date
1st Cartridge Change Date
2nd Cartridge Change Date
3rd Cartridge Change Date
4th Cartridge Change Date
5th Cartridge Change Date
6th Cartridge Change Date
7th Cartridge Change Date
8th Cartridge Change Date
9th Cartridge Change Date
10th Cartridge Change Date
11th Cartridge Change Date
12th Cartridge Change Date
13th Cartridge Change Date
14th Cartridge Change Date
15th Cartridge Change Date
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
______ / ______ / 20____
10
INSTALLATION DETAILS RECORD
Installer Name ................................................................................................
Installer Address .............................................................................................
............................................................................................................................
............................................................................................................................
............................................................................................................................
............................................................................................................................
............................................................................................................................
........................................................ Postcode ..........................................
Guarantee Card return date: ______ / ______ / 20____
11
MONARCH WATER
Additional Products available from Monarch Water
Water Softeners - Domestic
Water Softeners - Light Industrial
Water Softeners - Industrial
Water Softeners - Light Commercial
Water Softeners - Food Service Equipment Protection
Calcium Filters - Food Service Equipment Protection
Water Filters - Domestic
Water Filters - Food Service Equipment Protection
Water Purifiers - Domestic
Multiflo 3 Way Taps - Domestic
Monarch Water Ltd. Halesworth Road Bramfield IP19 9HP
T 01986 784759 F 01986 784769 [email protected] www.monarchwater.co.uk www.scaleout.co.uk

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Removes scale buildup
- Improves appliance performance
- Extends appliance lifespan
- Easy to install and maintain
- 3 year parts and 12 month labor warranty